2399 SPRUCE ST; ; CB901267; Permit
B U I L D I N G P E R M I T 08/28/90 08:13 Permit Project Development No: CB901267 No: A9001408 No : Page 1 of 1 Job Address: 2399 SPRU CE ST Str: Fl: Ste: Permit Type : RESIDENTAL ADDITION/ALTERATION Parcel No : 156-032-13-00 Valuation : 10,143 Construction Type : VN Occupancy Group: Class Code: Description: 483 SF DECK & 483 SF PATIO : COVER ROOF OVER DECK OWNER CONTRACTOR *** Fees HARING , JOSEPH GIBBS , RONALD PO BOX 4127 OCEANSIDE, CA Required *** Fees: n os 0:120190 ooo C II ,. o: 139.(.)0 Status: ISSUED Applied: 08/03/90 Apr/I ssue: 08/28/90 Validated By : DC Lie. OWNER Lie . C NO 619 721-9411 *** Adjustments: 209.00 .00 209.00 Total Credits: .00 70.00 1 39.00 Total Fees : Fee description Building Permit Plan Ch eck Strong Motion Fee * BUILDING TOTAL Total Payments : Balance Due : Un its Fee/Unit Ext fee Data 126.00 82 .00 1.00 209.00 'AL APPROVAL INSP.~ DATE 1Wz,hv CLEAR CE CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad CA 92009 (619) 438-1161 PERMIT APPLICATION • ••• City of Carlsbad Building Department EST. VAL _____ =._-=:.!...!...!_ ____ _ 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 1. A ' C 2. PERMIT TYPE TENANT IMPROVEMENT □NEW O TENANT IMPROVEMENT . . COMMERCIAL 0 INDUSTRIAL IB1fs1DENTIAL □APARTMENT □CONDO □SINGLE FAMILY DWELLING □ADDITION/AL TE RAT ION □DUPLEX □DEMOLITION □MECHANICAL □POOL □RELOCATION □MOBILE Hc»IE □ELECTRICAL □SPA □RETAINING WALL □SOLAR PROJECT INFORMATION PLAN CHECK No. □PLUMBING PLAN 0:: DEPOSlT ___ --=c---.aa.,...b'---- VALID. BY _____ l,-.<..,;:"'i--ct--x- DATE ________ ....J:4~.p~.L- 7187 \)8/03/91:;· 000.1 o: ( ·'.' C---i:<.:?<~T Clc..,tl-33 LEGAL DfSCRIPTION Lot No, Su&:li vision Name/NlM!"ber Unit No. Phase No, /3 /,As B,,O,!!£S CHECK BELOW If SUBMITTED: Q2 Energy Cales ASSESSOR'S PARCEL btSCRIPi ION OF WURK BLOG. SQ. FTG. IM'f'structural Cales 3. CONTACT PERSON • NAME /fo...,-<f>;JSZ-.$. CITY CJe,.~5,Pl! /, SIGNATURE ~.,...___. ~ 4. APP!...ICAN1, _ NAME ,Xd'At l"O ✓J:18,j • CITY O ~$~.S)b;:5" 5. PROPERTY OWNER . NAME V,, ~ H✓,.,,,;>;,,.,, &, CITY c:-,,:r_,e.__,. J!T '12) 6. CONTRACTOR , NAME 111: .. .,., 6 ; ,I$ Jf" ._,J CITY C, <-IZA-~;,,l},li;; SIGNATURE DESIGNER NAME Cl TY 7. WORKERS' COMPENSATION Q2 Soils Report D 1 Addressed Envelope EXISTING USE # OF STOll:IES ADDRESS STATE~ ZIP CODE DAY TELEPHONE PROPOSED USE 0 AGENT FOR CONTRACTOR ADDRESS OowNER 0 AGENT FOR OWNER STATE t!-/'!f ZIP COOEY" ..,.....2._ DAY TELEPHONE OWNER STATE STATE(!~ □LESSEE .5 p_,,:,._,,,.11!! _sr ZIP COOE DAY TELEPHONE ADDRESS j? t::J, & ./:f-• ..I( ZIP CODE 9.;J..1!1 T°.:,_ DAY TELEPHONE □TENANT LICENSE CLASS __ B ___ _ CITY BUSINESS LIC. # Tl TLE DATE ADDRESS STATE ZIP CODE DAY TELEPHONE STATE LIC. # Workers' COflllensat1on Declaration: hereby affirm that have a certificate of consent to self-insure issued by the Director of Industrial Relations, or a certificate of Workers' C~nsat ion Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Di rector of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C). INSURANCE Cc»IPANY :5//:J,-:~ ,A,,...,.,,l) POLICY NO. /t'!>b£e:t, ?-'7D EXPIRATION DATE ~ -9 / Certificate of EKeq,tion: I certify that in the performance of the work for which this permit is issued, I shall not eq,loy any person in any manner so as to become subJ ect to the Worker ' Coq,ensat, on Laws of Cal 1 forni a. SIGNATUR~ A . ,J'-.J'-;li!> 8. OWNER-BUILDER DECLARATION Qi.,ner·Builder Declaration: I hereby affirm that I am exempt from the Contractor's License Law for the folloi.,ing reason: D I as owner of the property or my eq,loyees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon., and who does such work himself or through his own eq,loyees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of c~letion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.). D I, as owner of the property, am exclusively contracting ,;ith licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property wtio builds or improves thereon, and contracts for such projects with contractor(sl licensed pursuant to the Contractor's License Law). D I am exe!)llt under Section ____________ Business and Professions Code for this reason: (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, al so requires the appl i cant for such permit to f i le a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, conmencing with section ?DOD of Division 3 of the Business and Professions Code) or that he is ex~t therefrom, and the basis for the alleged exeq,tion. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred do l lars [$500] ) • SIGNATURE DATE COMPLETE THIS SECTION fOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? □YES ONO ts the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □YES □No Is the facility to be constructed within 1,000 feet of the outer booodary of a school site? □YES 0,0 If ANY OF TffE MSWERS ME YES. A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1, 1989 UNLESS TIIE APPLICAfllT MS ,t:T OR IS ,t:ETING THE REQUIREMENTS Of THE OFFICE OF EMERGENCY SERVICES AND THE AIR POI.LUTIC. cc»ITROI. DISTRICT. 9. CONSTRUCTION LENDING AGENCY hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(il Civil Code). LENDER'S NAME LENDER'S ADDRESS 10. APPLICANT'S SIGNATURE I certify that I have read the application and state that the above information is correct. I agree to corrply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE INDEIUHFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST All LIABILITIES, JlllGENTS, COSTS ANO EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE Of THE GRANTING OF THIS PERMIT. Expiration. Every permit issuecl by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not coomenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is coomenced for a period of 1 0 days (Section 303(d) Uniform Building Code). APPLICANT'S~ □OIJNER □ BY PHO~E APPROVED BY: _______ _ DATE: WHITE: File YELLOW: Applicant PINK: Finance '. CITY.OF CARLSBAD INSPECTION REQUEST PERMIT# CB901267 FOR 10/12/90 DESCRIPTION: 483 SF DECK & 483 SF PATIO COVER ROOF OVER DECK TYPE: RAD JOB ADDRESS: 2399 SPRUCE ST APPLICANT: GIBBS, RON CONTRACTOR: GIBBS, RONALD OWNER: HARING, JOSEPH REMARKS: Tl/RS/RON/721-9411 SPECIAL INSTRUCT: TOTAL TIME: PHONE: PHONE: PHONE: INSPECTOR AREA PY PLANCK# CB901267 OCC GRP CONSTR. TYPE VN STR: FL: STE: 619 721-9411 619 721-94 1 CD LVL DESCRIPTION ACT COMMENTS _1_9 __ s_T _F_i_n_a_1_s_t_r_u_c_t_u_r_a_1 _______ ~ ______________ _ ------------------------------------ ***** INSPECTION HISTORY***** DATE 100990 092490 092090 083190 DESCRIPTION Final Structural Exterior Lath/Drywall Frame/Steel/Bolting/Welding Ftg/Foundation/Piers ACT INSP CO PY AP PY AP MP AP MP COMMENTS NEED HANDRAIL RELOCATED PATIO OK TO WRAP ESGIL COR'PORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, C~ 92123 (619) 560-1468 DATE: CRuj -a 1 '-1 o JURISDICTION: _C=--'-r-b--~0~4---C=6~r~'s~b_......,~-cl~ . .__ _____ _ PLAN CHECK NO: -~_,,___q......._.,C~J~c=-a...1~........,t,~7------=S=E~T~:~TC==------ PROJECT ADDRESS: o>3'-1 Cj Svwu.. 5-:C r PROJECT NAME: (,)0erc d ?c.,,T."'o IDeL\t. O...ch\ i"\7oi:, ""ip '$F:e. j • D □ 0 D D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified ______________ are resolved and check e d by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck . The applicant's copy of the check list is enclosed for the juris diction to return to the applicant contact person. The applicant's copy of the check list has been sent to: I! Esgil staff did not advise the app~icant contact person that plan check has been completed. D Esgil staff did advise applicant that the p lan check has b e en completed. Person contacted: ____________ _ Date contacted: ---------Telephone# ________ _ □ REMARKS: ___________________________ _ By : QQ...drc.. ESGIL CORPORATION 3-~0 □GA □AA Dvw OoM Enclosures:_~hlc.=...(0=-~~e,__~------ ,, ESGIL·CORPORA TION 9320 CHESAPEAKE OR., SUITE 208 SAN DIEGO, CA 92 I 23 (6 19 ) 560-14-68 T CA~T Jli~ISDICTION : ?L.?,N CHECK ~O: I C P;::;> 9 o -lcHR 7 S:ST: ('I) P~OJECT ADC~ESS:_~d_Y/_;_9_,_--'.S,__,.8:-=u~Lg~........::SJ:-....---'-·-------- □ LJ 0 • □ The plans trans~itted ~ere~it~ ~ave been corrected ~here necessary a~5 s~~sta~tially coI?lY ~it~ the j~risdiction's bui laing co-::::es. The pla~s tra~s~itted ::ere~i~~ will s~~sta~~ially COffi?lY with the j~risdiction's buildi~g codes when minor deficien- cies ice~tif:.e6 -,-----=--------.......,.--,----are resolved and chec~ed by ~~il~i~g de~artrne~t s~a::. ~he pla~s tra~smitted here~ith ~a~e significa~t d=~~c~=~c~=~ identifi~C en t~: e~clcseC c:;~c~ list a~a s~c~lQ ~e cc~r:c~e6 plans are list trans~itted ::e:e~it~ is fer yo~r i~forsaticn . are ~ei~g ~el6 at ~sgii Ccrp. u~til corrected s·..:brr:i ttea for rec::ec:-::. ~ 'o-t.\o~ T};e a?plic::.:"';t ' s jurisoict:.on to copy of t ~e c~eck list is enclosed for ~ne :et~rn to t~e applicant co~tact person . " -...., -;,,:: .--. --I.. • t::-::::J • "".J.· .... e ;:,p""'_· l_icc:.-..., .. 7'1 S cop)·' o-_~ ""._·_,..,,e c'...,-c..,. 11·c::."" 'nas ·o--n sent to: • □ Esgil staff did ~ot advise the ?lan chec~ ~as been completed. a?plicant t:1e contact person plan CGeC.'( Esgil staff did advise applica~t that been completed . Person contacted: ---------------- Da te contacted: -----------Telephone~ ----------- • RE!-'.:ARKS : ..z::...~~~="--.;,,I ~9v,..J.;,.;'1:,...:::U.:.."'~cJ~e...:r-f'}..IL.!....l..~'-=--'~..!:!1.+--±.~~=:l.!.!:..,a.!.!....:....IL!:!:..\,--.:c•-=-,,~1=-••:......:..' ...:."-.:...;• S:..:...,::.,...=.cl.c.•-=-'-~""-'~'-- #CD· ::,r, .. c .~0 o -';)~c... 0 /'2.. ~Ir. "iS~S • t-•c "''"' ,r-'' •!\2?Y'S-5"'0'-, 1 l c.&;,1t" '.\.:wv;,?>,1-\",\:s :i · ,(3): N ofi: I~ _ z: .. ,., 5-r;, r4 ,/, By : s ~d 'r-<.-- ES GIL CORPORATION ~-& LJGA DP.A Dvw OoM Enclosures:_~&-'~o~n_< ________ _ . ... -· . ,. . . . . • • Date, 8 -1'-l 4 o' .?r epar ed "o)' 1 Jurisdiction Ur Is b ~o--o 3ldg, Dept, ~tu:\~ c:r-::sgil ?LAH CH£CX ?'iO • C.6 '1 D -Id-(./] <.:£) 3U1LD1l\G ADD~::SS ...)3"19 ;:,P,vc, :f>"C • A??LICAt-l'l'/CO~TAC'l' 12.o,,., ~.bbs 3\J!!..D!~C OCCU?.t-.~C't --~------ TY?== O? CO?\ST~UC?!.ON ~ - • I •• 3\JILD!~G ?C~T10H =, .1.L,' ! 1-u-· !rNc A ;i :::_; --0 ~ c..1.L . I 4g3 I ?~ I t-/33 \ I I I t I I I I I I I . Air Condi tioninz: Commerc1a'l . 1 Residential --I '• Res. or Comm. ---I -· rire S'Dr inkl ers ·· ' Total Value I 81.:ildirig Perndtree.S Plan Chec\c rte s COHHCNTS ?~~ON2 NO. 7~ \ -Ct '-HI Dt:SJCl,:::~ ?r.D~E ------ CONT~ACTO~ ?HONE ----- -I V.!.LUA?J:Ol'l I VALU:.: ).';\J L'I'J ?LI::~ I / u . <:o I 6t':l77- I I I I u .6() I C::r,'7_...).. ,..- \ I I I I I I I I I I I I I . I I I I I I I 1. I I .@ -I I (a , I @ -I ' I I -I D, \L.\3, .. s /~ Cp 'Do s ,. '10 SHEET 0 OF {'~ ~ 12/87 J ~ :r &J (JJ Q_· 0. <r BUILDING PLANCHECK ENGINEERING CHECKLIST [ZI © ITEM COMPLETE ITEM INCOMPLETE - NEEDS YOUR ACTION 1 2 S N T D DATE: 22 A UG 90 PLANCHECK NO. C,0-12( I 3 2399 SPRUC.E T" R D A.~N 15(:,-032-13 _X_ITEM SELECTED C C C PROJECT ID: ____________ _ H H H E E E LEGAL REQUIREMENTS C C C ~ K K Site Plan D D 1. Provide a fully dimensioned site plan drawn to scale. Show: north arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of- G2l □ □ ci □ □ FRMOOlO.DH way width and dimensioned setbacks. 2. Show on site plan: Finish floor elevations, pad elevations, elevations of finish grade adjacent to building, existing topographical lines, existing and proposed slopes, driveway with percent(%) grade and drainage patterns. 3. Provide legal description and Assessors Parcel Number . Discretionary Approval Compliance ./ 4. No Discretionary approvals were required. ___ 5. Project complies with all Engineering Conditions of Approval for Project No. ________ _ ___ 6. Project does not comply with the following Engineering Conditions of Approval for Project No. ________ _ Conditions complied with by: _______ Date: ___ _ Field Review N/A 7. Field review completed. No issues raised . • ___ 8. Field Review completed . The following issues or discrepancies with the site plan were found: __ A. ___ B. ___ c. __ D. Site lacks adequate public improvements. Existing drainage improvements not shown or in conflict with site plan. Site is served by overhead power lines. Grading is required to access site, create pad or provide for ultimate street improvement. 08/29/89 FRMOOlO .DH ___ E. Site access visibility problems exist. Provide onsite turnaround or engineered solution to problem. ___ F. Other: ___________________ _ Dedication Requirements _Lg, No dedication required . ___ 10 . Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate 1 ega 1 description together with an 8~" x 11" plat map and submit with a title report and the required processing fee. A 11 easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. The description of the dedication is as follows: _____________________ _ Dedication completed, Date: ____ _ By : ____ _ Improvement Requirements _L11. No public improvements required. SPECIAL NOTE: Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the City inspector prior to occupancy . ___ 12. Public improvements required . This project requires construction of public improvements pursuant to Section 18.40 of the City Code. Please have a registered Civil Engineer prepare appropriate improvement plans and submit. for separate plancheck process through the Engineering Department. Improvement p 1 ans must be approved, appropriate securities posted and fees paid prior to issuance of permit . The required improvements are: _________________ _ Improvement plans signed, Date: ____ _ By: ____ _ 08/29/89 FRMOOlO.DH ___ 13. Improvements are required. Construction of the public improvements may be deferred in accordance with Section 18.40 of the City Code. Please submit a letter requesting deferral of the required improvements together with a recent tit 1 e report on the property and the appropriate processing fee so we may prepare the necessary Future Improvement Agreement. The Future Improvement Agreement must be signed, notarized and approved by the City prior to issuance of a Building Permit. Future Improvement Agreement completed, Date ______ _ By: ______ _ Grading Requirements ___ 13a. 15. Inadequate information available on site plan to make a determination on grading requirements. Please provide more detailed proposed and existing elevations and contours. Include accurate estimates of the grading quantities (cut , fill, import, export). No grading required as determined by the information provided on the site plan . Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted for separate plan check and approval through the Engineering Department. NOTE: The Grading Permit must be issued and grading substantially complete and found acceptable to the Ci ty Inspector prior to issuance of Building Permits. Grading Inspector sign off. Date: ______ By: ___ _ Miscellaneous Permits / 16. Right-of-Way Permit not required. __ 17. __ 19. Right-of-Way Permit required. A separate Right-of-Way Permit issued by the Engineering Department is required for the following: ___________________ _ Sewer Permit is not required. Sewer Permit is required. A Sewer Permit is required concurrent with Building Permit issuance. The fee required is noted below in the fees section. Industrial Waste Permit is not required. 08/29/SS FRMOOlO.DH _21. Industrial Waste Permit is required. Applicant must complete Industrial Waste Permit Applicantion Form and submit for City approval prior to issuance of Building Permits. Permits must be issued prior to occupancy. Industrial Waste Permit accepted -Date: _____ By : ______ _ Fees Required Park-in-Lieu Fee Quadrant : __ Fee per Unit : ______ Total Fee: __ _ ~:....L..23 . Traffic Impact Fee Fee Per Unit : ______ Total Fee: __ _ ~~24 . Bridge and Thoroughfare Fee Fee per Unit: ______ Total Fee: __ _ 1...-4-......_25. Public Facilities Fee required . Facilities Management Fee Zone: ____ _ Fee: __ _ Sewer Fees Permit No . ______ EDU 's ______ _ Fee: _____ _ 1:i/8-28. Sewer Lateral required: ______________ _ Fee : ______ _ __ REMARKS: _____________________ _ ENGINEERING AUTHORIZATION TO ISSUE PERMIT BY: S,SC.HF..DELL Date: 22-ALB 90 08/29/89 ~ i ~ l ~ I OJ ~ ~ ~ ... .. .. .. .. .. Q Q Q ~I I I >-..c >-..c ~ -N -~ ~ ~ ~ u ~ u ~ u ~ .c u .c u .c u C: C: C: ., .. .. ~ ~ ~ tefcJ □ ~□ PLANNING CHECKLIST Plan Check No . t/'O-/"2, 67 Address 2-3 9 'f ~,e..u;r >' r. APN: t_%-,o-;3 z_ -(1. Planner IJ A -l,"t_A.J c,,h. Phone 438-1161 Type > (Name) of Project and Use ll--1 i¾-rro c,pJ(;L <;F;l:>. Zone Facilities Management Zone legend 111 Item Complete @ Item Incomplete -Needs your action 1, 2, 3 Number in circle indicates plancheck number that deficiency was identified Environmental Review Required: YES __ NO~ TYPE _____ _ DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval Discretionary Action Requ'i?·ed: YES __ NO -,X._ TYPE _____ _ APPROVAL/RESO . NO. PROJECT NO. OTHER RELATED CASES: DATE: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval Coastal : YES __ NO -'Y,._ DATE OF APPROVAL: Compliance with conditions of approval? If not, state conditions which require action . Conditions of Approval s6 □ J□□ uJtJ □ cl□□ B""□ □ c:1'□□ ~□ □□□ Landscape Plan Required: YES ___ NO X.... See attached submittal requirements for landscape plan£ Site Plan: 1. Provide a fully dimensioned site plan drawn to scale . Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width and dimensioned setbacks. 2. Show on Site Plan: Finish floor elevations, elevations of finish grade adjacent to building, existing topographical lines, exi sting and proposed slopes and driveway. 3. Provide legal description of property. 4. Provide assessor's parcel number. Zoning: 1. Setbacks : »/4 pY Front: ~,J Int. Side: 2. 3. 4. Street Side: Rear : Lot coverage: Height: Required Required Required Required 2-& ?.~ JO 20 Shown _~_o_' Shown Shown Shown 6' '4 . z.r.s-' Required C:: cto1;' Shown < 'fO; / p _,-I (.,, ,.-/ Required ~ .:>J Shown __ _._~_ Spaces Required -z-Shown Parking : Guest Spaces Required ___ Shown __ _ Additional conments and remarks have been made on the building plans. These marked-up plans may be picked up at the Building Department. These marked- up plans must be resubmitted with the revised plans for this project. Have plans been marked up? YES __ _ NO A_ Additional Comments _______________________ _ OK TO ISSUE 11 ~ DATE PLNCK .FRM