Loading...
HomeMy WebLinkAbout1865 SPYGLASS CT; ; CBR2018-1490; Permit( City of Carlsbad Residential Permit Print'Date: 05/13/2019 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: Description: 1865 Spyglass Ct BLDG-Residential 2073853200 $34,421.33 Work Class: lot#: Reference#: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: HART: 103 SF ADDITION, 203 SF REMODEL Owner: Addition COOWNER GREGSON BRIAN C AND JESSICA B H BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) 1865 Spyglass Ct CARLSBAD, CA 92008 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL $B1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL SWPPP INSPECTION FEE TIER 1-Medium BLDG SWPPP PLAN REVIEW FEE TIER 1 -MEDIUM Total Fees: $1,142.47 Total Payments To Date: $1,142.47 Status: Applied: Issued: Permit Finaled: Inspector: Final Inspection: Balance Due: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020{a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Permit No: CBR2018-1490 Closed -Finaled 06/22/2018 08/10/2018 05/13/2019 Tfraz 5/13/2019 3:30:2SPM $0.00 $310.00 $217.00 $41.00 $170.00 $42.00 $62.00 $2.00 $4.47 $238.00 $56.00 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov ¥ " THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: 0 PLANNING 0 ENGINEERING (City of Carlsbad LOT# Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-11558 email: building@carlsbadca.gov www.carfsbadca.gov PHASE# □BUILDING □FIRE □HEALTH 0 HAZMATIAPCD 5o I 3 VB 0 7N)'~"'~-k~(lo1: 01 sr) "-+ S<111..th-ete-v:~~, w1-H,. {1'1) fer[l.v!~, /0-¥\.<L e..cvue._cJ...._ 'Ptx.-ko ~ {if-~ f sfi) . Lttf-e,y,!IY' f.2.e..wl"£le..l 1n.c..lL1.ol~ ~ 1· {.N) ~ptUlde.d ope-wi o..+ ~e.¥\ f t-Wtd__ L"1) wdw.s. /VI. ~@03s~ ~~ P%f] DECKS(SF) 0 AIR CONDITION~ ARE SPRINKLERS YES0NOLILJ YES0N Al'PIJCANT ..... A I Is~ C1C,l,\.e.. loex ADDRESS ~5o5 Tr,es + cm Cu-lsl?A£l.. ZJP q-u:i,o ZIPCJ2-0oz PHON 'i18'l -Sci3 EMAIL ADORESS CITY STATE ZJP cm STATE ZJP PHONE FAX PHONE FAX EMAIL EMAIL STATE UC.# STATE UC.# ""55 CITY BUS. UC.# (Sec. 7031.5 Business and Professions Code: Any Cib' Of County which requires a permit to construct. alter, Improve, demolish or repair any structure, prior to Its issuance, atso l]lQUires the applicant for such permit to file a siar18d statement tllat he Is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of OMslon 3 of the Business and Professions Code} or Ihet he is e.xemm, therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any appllcantfor a permit subjects the applicant to a civil penalty of not more than flY8 hundred dollars {$500)). WORKERS' COMPENSATION Workers' Compensation Declaration: I hereby affirm under penally of perjury one of the following declarations: D I hive and wll maintain a certificate of conaent to self-Insure for'M)l'1(ers' compensation as provided by Section 3700 Of the labor Code, for the performance of the WOii( for which this permit Is issued. D I have and w111 maintain workers' compensation, as requi'ed by Secllon 3700 of the Labor Code, for lhe performance of the WOOi. for which thlS permit IS iSsued. My workers' compensatlon Insurance earner and policy number are: Insurance Co. __________________ Poley No. ____________ -Dale _______ ~ !bl,section need not be completed If lhe permit is forooe hundred dcllars ($100) or less. LJ Certificate of Exemption: I cef1ffy that in the pe<formanai of the work for which this permit Is Issued, I shan not employ any persoo In any manner so as to become subfed to the Workers' Compensation Laws of California. WARNING: Failure to aecure worten' compensation coverage is unlawful, and shall subject an employef to criminal penalties and ciYII fines up to one hundred thousand dollars (&100,000), in addition lo the cost of compensation, damages as provided for in Section 3706 of the Labor code, intemt and attorney's fees. ~ CONTRACTOR SIGNATURE □AGENT DATE ,. CJW'lltlflt•9 U•tL DER DEC LA RATION I hereby afflml that I am exempt from Contractor's Ucense Lew for the following reason: D I, as owner of lhe property or my emptoyees with wages as their sole compensation, wHI do the work and lhe structure is not Intended or offered for sale (Sec. 7044, Business and Professklos Code: The Contractor's Uceose Law does not apply to an owner of property who builds or Improves thereon, and whO does such work himself or through his own employees, provided that SUCh Improvements are not Intended or onered for ~-tf, tiowever. the building or Improvement is sold within one year of compleliOn, the owner-builder wig have the burden of proving that he did not build or Improve for the purpose of sale). llt'.J I, as owner of !he property, am exclusively contracting with li<:ensed contractofs to coostruct the project (Sec. 7044, Business and Professions Code: The Cootraelor's License Law does no1 apply to an O'l'KIElr Of property who builds or Improves thereon, and contracts for such pro;ects with contractor(s) licensed pursuant to the Contractor's License Law). □ I am exempt underSedlon ____ ,Business and Professions Code tor this reason: 1. I personally plan to provide the major labor and materials for construction Of the proposed property Improvement. Oves []No 2. I (have I have not) signed an application for a building permit for the proposed work. 3. t have contracted with the folk:Ming person (firm) to provide the proposed construction (include name address I phone I contractors' li<:ense number): 4. I plan to provide IX)f1lons oflhe work, but 1 have hired the following person to coordinate, supervise and provide the majOr work (Include name I address I phone I contractors' license number): 5. U prow:18 some of t_!l8: WOl"i(, but I have (hired) folk:M,ing P8fSOOS to provide the work Indicated (Include name I address I phone I type of WOl"1< : OWNER SIGNATURE □AGENT DATE ,COMPLETE THIS SECTION FOR NON•RESIDENTI.At BUHDING l'ERMITS ONLY Is the appicari or futt.re buking occtJpEIII 19qlired ti submit a business plal, acutely haz.-dous mcierlas reiilStr.iion brm or riSk nmagement 800 prevention progran under Sections 25505, 25533 or 25534 of the PTesley-TannerHazadousS~Accountlv.;f? □Yes □No Is the applk:anl orfutt.re building occupant required ti obtain a permit from Ille air pollution control district or air quality man~ement dlstrict? □ Yes □ No Is the fa:itily to be c:oo.trocled within 1,000 feet Of the outer IXJurK1ay of a sctoo s/E? □ Yes □ No IF ANV OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLWflON CONTROL DISTRICT. I hereby affirm lhat lhele ~ a construdion lending agency for Ille pelfomlance at Iha wak lho permit m issued (Sec 3097 (1) CM Code). Lender's Name Lender's Address APPLICANT CERTIFICATION I catifythatl hiM l9ild tfleapplcallon and state that the aboWI infonnatlon ts mnectand tbatthe lnfoonallon oathe plans IS accwa1B. I acrae 1Dcomplywllb allOIJoldnances and 51:111111 INs 191atingl:I bulklngoonstruction. I heteby--u,,,ct"' atyctCalslled kl-ui,n the abole ""'1llllled propertyb-l)Ull068S. I ALSO AGREE TOSA\IE, II\IJEM'IIFY AND KEEP HARt.t.ESS TIE CITY OF CAAlSBAD AGAINST ALL UA9UTIES, JUDGMOOS, COSTS AND EXPENSES 1M-ICH MAY IN ANY WAY ACCRUE AGAJNST SAD CITY IN CONSEQUENCE OFTI-E GRANTING OF THIS PERMIT. OSHA: All OSHA pemit o R!(Jliad b """""°"°""SO' deep aid _lion c, oonsuudion ct s1nctles""" 3 sbies i1 h<ighl EXPIRATIOl-t EIOI\' pem,il osued bythe !ullillJ Oftljaf llldE,-.... _oflho Cooeshal axpire by llrilai:ln "1d becomenul aid ,lil ithebuldi1g c,-"""'2ed byll.dl pemitis nofoonm,road wim 100 days 1mm the dae ct w pemit a,"' bl.Od~ """" -by w pennt s suspended a alla1ttJned a1 anyln"e m the""" is <XllllQlOOld b a perod ct 100 days (Secion 1116.4.4 Lnbm a,~~ Cale). AS APPI.ICAIIT'S SIGNATURE DATE Ce '2 '2--, le, PERMIT INSPECTION HISTORY REPORT (CBR2018-1490) Permit Ty'pc: BLDG-Residential Applic<1tlon Date: 06/22/2018 Owner: Work Class: Addition Issue Date. 08/10/2018 Subdivision: Status: Closed -Finaled Expiration Date: 10/22/2019 Address: IVR Number: 12106 Scheduled Date Actual Start Date Inspection Type Inspection No. Inspection Status Primary Inspector 04125(2019 04(25/2019 May 13, 2019 BLDG-Fina/ Inspection 089943-2019 Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLOG-Mechanical Final BLDG-Structural Final BLOG-Electrical Final Partial Pass Tim Frazee COMMENTS Owner wants to take the Pergola out of the project It will no longer be connected to the house, structure. He will come to Faraday and modify the Permit COOWNER GREGSON BRIAN C AND JESSICA B H CARLSBAD TCT#82-05 A 1865 Spyglass Ct Carlsbad, CA 92008-3770 Re inspection Reinspection Passed No Yes Yes Yes Yes Complete Incomplete Page 3 of 3 PERMIT INSPECTION HISTORY REPORT (CBR2018-1490) Permit Type: BLDG-Residential Application Date: 06/22/2018 Owner: COOWNER GREGSON BRIAN C AND JESSICA B H Work Class: Addition Issue Date: 08/10/2018 Subdivision: CARLSBAD TCT#82-05 A Status: Closed -Finaled Expiration Date: 10/22/2019 Address: 1865 Spyglass Ct Carlsbad, CA 92008-3770 IVR Number: 12106 Scheduled Actual Reinspection Complete Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Checklist Item COMMENTS Passed BLDG-Building Deficiency No BL0G-14 No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers 10/29/2018 10/29/2018 BLDG-84 Rough 074318-2018 Cancelled Paul Burnette Relnspection Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLOG-Building Deficiency No BLOG-14 No Frame-Steel-Bolting-Welding (Decks) BLOG-24 Rough-Topout No BLOG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers 10/31/2018 10/31/2018 BLOG-84 Rough 074706-2018 Failed Paul Burnette Reinspection Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLOG-14 No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BL0G-44 No Rough-Ducts-Dampers 11/02/2018 11/02/2018 BLOG-13 Shear 074959-2018 Passed Tim Frazee Complete Panels/HO (Ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLOG-16 lnsulatlon 074958-2018 Passed Tim Frazee Complete Checklist Item COMMENTS Passed BLOG-Building Deficiency Yes 11/07/2018 11/07/2018 BLOG-17 Interior 075464-2018 Passed Tim Frazee Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes May 13, 2019 Page 2 of 3 . --~··----·---~··. PERMIT INSPECTION HISTORY REPORT (CBR2018-1490) Permit Type: BLDG-Residential Application Date; 06/22/2018 Owner: COOWNER GREGSON BRIAN C AND JESSICA B H Work Class: Addition Issue Date: 08/10/2018 Subdivision: CARLSBAD TCT#82-05 A Status: Closed -Finaled Expiration Date: 10/22/2019 Address: 1865 Spyglass Ct Carlsbad, CA 92008-3770 IVR Number: 12106 Scheduled Actual Inspection Status ReinspecUon Complete Date Start Date Inspection Type Inspection No. Primary Inspector 05/13/2019 BLDG-Final 091840-2019 Passed Tim Frazee Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Owner wants to take the Pergola out of the No project. It will no longer be connected to the house, structure. He will come to Faraday and modify the Permit. BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLOG-Electrical Final Yes 08/13/2018 08/13/2018 BLDG-SW-Pre-Con 066765-2018 Passed Paul Burnette Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency No 08/14/2018 08/1412018 BLOG-11 066901-2018 Failed Michael Collins Reinspectlon Complete Foundation/Ftg/Pier s (Rebar) Checklist Item COMMENTS Passed BLOG-Building Deficiency Not ready No 08/27/2018 08/27/2018 BLOG-11 068261-2018 Failed Paul Burnette Reinspection Complete Foundatton/Ftg/Pler s (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No 08129/2018 08129/2018 BLOG-11 068510-2018 Partial Pass Paul Burnette Re inspection Incomplete Foundatlon/Ftg/Pler s (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No 10116/2018 10/16/2018 BLOG-15 073319-2018 Passed Paul Burnette Complete Roof/ReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 10/17/2018 10/17/2018 BLDG-13 Shear 073337-2018 Passed Paul Burnette Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 10125/2018 10/25/2018 BLDG-84 Rough 074212-2018 Failed Paul Burnette Reinspection Complete Combo(14,24,34,44) May 13, 2019 Page 1 of 3 EsG1I DATE: 08/06/18 JURISDICTION: Carlsbad PLAN CHECK#.: CBR2018-1490 PROJECT ADDRESS: 1865 Spyglass Ct. SET II PROJECT NAME: Addition and Remodel for Hart Residence □ APPLICANT _y/4JRIS ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: Alisa Eichelberger ~ EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Alisa e~erger Telephone#: 760-889-8931 Date contacted: ( '() 0 ) Email: alisa@adesign-shop.com Mail Telephone Fax In Person 0 REMARKS: By: Javier Snider (KF) EsGil 07/27/18 Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 ✓• EsG1I DATE: July 3, 2018 JURISDICTION: Carlsbad PLAN CHECK#.: CBR2018-1490 PROJECT ADDRESS: 1865 Spyglass Ct. SETI PROJECT NAME: Addition and Remodel for Hart Residence □ APPLICANT □ JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. IZJ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. IZJ The applicant's copy of the check list has been sent to: Alisa Eichelberger D EsGil staff did not advise the applicant that the plan check has been completed. IZJ EsGil staff did advise the applicant that the plan check has been completed. □ Person contacted: AJ.isa Eichelberger Telephone#: 760-889-8931 Date co)Pt:~~~ /~ (by:@,) Email: alisa@adesign-shop.com Mail Fax In Person By: Kat Frankowski EsGil 6/25/2018 Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad CBR2018-1490 July 3, 2018 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK#.: CBR2018-1490 PROJECT ADDRESS: 1865 Spyglass Ct. FLOOR AREA: Addition= 103 SF Patios = 431 SF Remodel = 203 SF REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 6/22/2018 DATE INITIAL PLAN REVIEW COMPLETED: July 3, 2018 FOREWORD (PLEASE READ): JURISDICTION: Carlsbad STORIES: 2 HEIGHT: DATE PLANS RECEIVED BY ESGIL CORPORATION: 6/25/2018 PLAN REVIEWER: Kat Frankowski This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2016 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC, 2015 UPC, 2015 UMC and 2014 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carli;bad CBR2018-1490 .;July 3, 2018 PLANS 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 3. Plans deviating from conventional wood frame construction shall have the structural portions signed and sealed by the California state licensed engineer or architect responsible for their preparation, along with structural calculations. (California Business and Professions Code). 4. Please coordinate the labels for the patios, their labels don't match between structural calcs and architectural sheets. EXITS, STAIRWAYS, AND RAILINGS 5. Show landings at exterior doors. There shall be a landing or floor on each side of each exterior door. The width of each landing shall not be less than the door served and have a minimum or 36-inches measured in the direction of travel. Exterior landings shall be permitted to have a slope not to exceed ¼-inch per foot. Landings or finished floors shall not be more than 1.5 inches lower than the top of the threshold for outward swinging exterior doors or 7.75" for doors that do not swing outwards. R311.3. ROOFS/DECKS/BALCONIES 6. The roofing shown on plans is not adequate for roof slope that is less than 2.5: 12. One of the roof sections you show is 2: 12, please address. FOUNDATION REQUIREMENTS 7. Note on plans that surface water will drain away from building and show drainage pattern. The grade shall fall a minimum of 6" within the first 1 O feet. Section R401.3. Carlsbad CBR2018-1490 .,July 3, 2018 STRUCTURAL 8. Is there a second header above the transom window? 9. Please label all new beams that are in the calcs, some have similar spans and are hard to locate. 10. In the structural calcs it appears that the EB2 has a larger span on plans than in calcs. 11. Per calcs FB2 should be 5 ¼" x 11 7/8". 12. In lateral analysis level 1 line 3, ii shows you have 1 0' of shear walls, but I only see 2 sections that add up to 7'4". 13. In lateral analysis level 1 line 5, it shows you should have 3' of shear walls but I do not see any. ELECTRICAL 14. Include on the plans the following specifications for electrical devices installed in dwellings: CEC Article 21 0 & 406 a) Tamper resistant receptacles for all locations described in 210.52 (i.e., all receptacles in a dwelling). 15. A balcony, deck, or porch that is accessible from the interior of the dwelling will require a minimum of one receptacle outlet. CEC 210.52(E) (3). This receptacle must be GFCI protected. Residential Energy Lighting Requirements: ES 150.0(k) 16. All installed luminaires shall be high-efficacy in accordance with ES TABLE 150.0-A. Light sources that are not marked "JA8-2016-E" shall not be installed in enclosed luminaires. ES 150.0(k) 17. In bathrooms, garages, laundry rooms, and utility rooms at least one luminaire shall be controlled by a vacancy sensor. 18. Dimmers or vacancy sensors shall control all LED style luminaires. Two exceptions: Fixtures installed in hallways or (closets under 70 square feet). 19. Recessed can light fixtures shall be IC listed, air-tight labeled, and not be equipped with a standard medium base screw shell lamp holder. ES 150.0(k) 20. SFD outdoor lighting fixtures that are attached to a building are required to be high efficacy, be manually on/off switch controlled, and have both motion sensor and photocell control. See ES 150.0(k) 3 for additional control options. Carlsbad CBR2018-1490 July 3, 2018 MISCELLANEOUS 21. Applicant to sign soil stamp at city. 22. Please complete the Carlsbad special inspection form attached at the end of this document. 23. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 24. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No □ 25. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Kat Frankowski at EsGil. Thank you. Carlsbad CBR2018-1490 July 3, 2018 «~'» ~ CITY OF CARLSBAD SPECIAL INSPECTION AGREEMENT B-45 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov In accordance with Chapter 17 of the California Building Code the following must be completed when work being performed requires special Inspection, structural observation and construction material testing. 'roject/Permit: ___________ Project Address_· ------------------ A. THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNER/AUTHORIZED AGENT. Please check e you are Owner-Builder □. (If you checked as owner-builder you must also complete Section B of this agreement.) Name: (Please print,_ _______________________________ _ (First) (Ml) (Last) Mailing Addres,,,._· --------------------------------- Emai._· ________________________ Phone_· _________ _ I am: □Property owner □Property owner's Agent of Record □Archrtect of Record □Engineer of Record state of California Registration Numbe · Expiration Date: _______ _ AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the State of California, that I have read, understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural observations, construction materials testing and off-site fabrication of building components, as prescribed in the statement of special inspections noted on the approved plans and, as required by the California Building Code. Signatur~·~ ______________________ Date: ___________ _ B. CONTRACTOR'S STATEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the contractor/ builder/ owner-builder. Contractor's Company Name: __________________ Please check if you are Owner-Builder D Name: (Please print) ________________________________ _ {First) (M.I.) (Last) Mailing Address: _________________________________ _ Email: ________________________ Phone_· __________ _ state of California Contractor's License Number· __________ Expiration Date: _______ _ • I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on the approved plans; • I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the building official; • I will have in-place procedures for exercising control within our (the contractor's) organization, for the method and frequency of reporting and the distribution of the reports; and • I certify that I will have a qualified person within our (the contractor's) organization to exercise such control. • I will provide a final report I letter In compliance with CBC Section 1704.1.2 prior to requesting final inspection. Signature~: ______________________ ,Date: __________ _ B-45 Page 1 of 1 Rev. 08/11 • Carlsbad CBR2018-1490 July 3, 2018 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Kat Frankowski BUILDING ADDRESS: 1865 Spyglass Ct. BUILDING OCCUPANCY: BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance ----- 1997 USC Buildin Permit Fee g ... ....... .. .. . . ..... ·-1 1997 USC Plan Check Fee • Type of Review: Complete Review D Repetitive Fee 3 Repeats Comments: □ Other D Hourly EsGil Fee PLAN CHECK#.: CBR2018-1490 DATE: July 3, 2018 Reg. VALUE ($) Mod. 34,421 34,421 D Structural Only ,__ __ ___.I Hr. @ • $176.981 Sheet 1 of 1 LOVELACE ENGINEERING Structural Engineering Services 5930 Cornerstone Court W. Suite 100 San Diego, CA 92121-3772 phone 858.535.9111 • fax 858.535.1989 • www. lovelaceeng.com Digitally signed by Miles Lovelace ~ ~ ~ ~ ~ ~ ~ 21 I ---l--=----1 ((I 56 Jl8204 -1-iart Reer dence JOB ______________________ _ SHEET NO. ____________ OF _______ _ TAM :l/21&/18 CALCULATEOBY ___________ DATE ______ _ CHECKEDBY ____________ DATE ______ _ SCALE _____________________ _ STORM WATER POLLUTION PREVENTION NOTES 1. ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE AVAILABLE ON SITE TO FACILITATE RAPID INSTALLATION OF EROSION AND SEDIMENT CONTROL BMPs WHEN RAIN IS EMINENT. 2. THE OWNER/CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY INSPECTOR AFTER EACH RUN-OFF PRODUCING RAINFALL. 3. THE OWNER/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY INSPECTOR DUE TO INCOMPLETE GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. 4. ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PECENT ( 40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. 5. ALL GRAVEL BAGS SHALL CONTAIN 3/4 INCH MINIMUM AGGREGATE. 6. ADEQUATE EROSION AND SEDIMENT CONTROL AND PERIMETER PROTECTION BEST MANAGEMENT PRACTICE MEASURES MUST BE INSTALLED AND MAINTAINED. 7. THE CITY INSPECTOR SHALL HAVE THE AUTHORITY TO ALTER THIS PLAN DURING OR BEFORE CONSTRUCTION AS NEEDED TO ENSURE COMPLIANCE WITH CITY STORM WATER QUALITY REGULATIONS. OWNER'S CERTIFICATE: I UNDERSTAND AND ACKNOWLEDGE THAT I MUST: (1) IMPLEMENT BEST MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION ACTIVITIES TO THE MAXIMUM EXTENT PRACTICABLE TO AVOID THE MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO AVOID THE EXPOSURE OF STORM WATER TO CONSTRUCTION RELATED POLLUTANTS; AND (2) ADHERE TO, AND AT ALL TIMES, COMPLY WITH THIS CITY APPROVED TIER 1 CONSTRUCTION SWPPP THROUGHOUT THE DURATION OF THE CONSTRUCTION ACTIVITIES UNTIL THE CONSTRUCTION WORK IS COMPLETE AND APPROVED BY THE CITY OF CARLSBAD. i__C?r1,wa (/2 r eef>!U DATE -29 STORM WATER COMPLIANCE FORM TIER 1 CONSTRUCTION SWPPP ~o,e --1qq() BEST MANAGEMENT PRACTICES (BMP) SELECTION TABLE Erosion Control Sediment Control BMPs Tracking Non-Storm Water Waste Management and Materials BMPs Control BMPs Management BMPs Pollution Control BMPs C: C: C: 0 ..... ..... 0 0 :;::; C: C: -0 :;::; :;::; O> 0 Q) -0 Q) -0 CJ) C: (,) (,) C: C: O> E C: E C: ..... 0 ..... ::, ::, 0 '6 ·.::: a. 0 0 0 E Q) L L :;::; L ·5 Q) ::::!e -0 CJ) O> L ..... ..... C: '->. O> C: Q) L C: Q) c CJ) CJ) CJ) 0 ·.::: O" L 0 C: O> Oc a. Q) ·a. ·.::: -C: CJ) C: > L w Q) 0 Best Management Practice* ~ C: 0 CD L 0 Q) 0 L (.!) Q) > C: :;::; :c CJ) 3: CJ) ~ Q) 0 C: OL 0 Q) ..... Q) 0 ..... C: E Q) O> ·o c: CJ) -0 CJ) ~ -0 Q) CJ) ::::!e C: Q) C: (BMP) Description ➔ CJ) (,) Q) (/) ·~ CJ) O> CD O> C: C: ~ ..... Q) Q) 0 :::, Q) :5 ~ Q) ..... 0 0 3: C: L 0 -ow -0 >. 0 CJ) C: C: 0 i!:l E :;::; (,) C: 0 0 CD (/) ·-O> D:;::; Q)' ~o 0 Q) 0o O> Q) Q) >< ::::!e 0 O> 0 C: Q) e::: E 0 N CJ> (,) en~ Q) Q) C: c Q) c ·a. L-3: Q) Q) 0 Q) E .Y. 1 ..... ::, ..c E :rl ;:: l3 = 3: .._ +i ::0 u·c ·-O> ·.::: a.. 0 O> -0 .c C: Q) LL (,) L Q) ::, -0 ·--0 C: 0 L 0 .Y. L -0 0 ..... -+-'•-a. '6 L-+-' ..C L ..c 0 Q) (,) •-L 0 ·-0 Q) L Q) (,) _ ..... 0 0 Q) Q) Q) (,) C: ..... 0 fj :g_ .... ..... 0 ..... = C: ·-C: ~ L 0 0 .... ..c 0 l:;o 00 0 O> .B 0 .c Q) 0 Q0 Q) 0L Q) .c L 0 +' L U) C: 0L 0 ~o o...., 0 ..... a.o (.!) WO 1n vi (/) 0 ~ (.!) (/)> (/) (/) a.. (/) e::: 3: a.. a..o a.. ::::!e (/) ::::!e (/) (/) 0 (/) ::::!e CASQA Designation ➔ r---co a> ..-I") '<t tr) tO r---co 0 N I") r---co N I") '<t tr) 'T ..-..-..-..- I I I I I I I I I I I I I I I I I I I 1· I I 0 0 0 0 w w w w w w w w g: g: (/) (/) (/) (/) ::::!e ::::!e i i i . Construction Activity w w w w (/) (/) (/) (/) (/) (/) (/) (/) z z z z 3: 3: 7-Gradinq/Soil Disturbance )a,( , Trenchina/k:xcavation Stockoilina Drillina/Borina Concrete/ Asphalt Sawcuttina Concrete Flatwork Pavinq Conduit/Pipe Installation Stucco/Mortar Work 1')< Waste Disoosal l><- Staqinq/Lay Down Area Eauioment Maintenance and Fuelina Hazardous Substance Use/Storaqe Dewaterina Site Access Across Dirt Other (list): Instructions: 1. Check the box to the left of all applicable construction activity ( first column) expected to occur during construction. 2. Located along the top of the BMP Table is a list of BMP's with it's corresponding California Stormwater Quality Association (CASQA) designation number. Choose one or more BMPs you intend to use during construction from the list. Check the box where the chosen activity row intersects with the BMP column. 3. Refer to the CASQA construction handbook for information and details of the chosen BMPs and how to apply them to the project. PROJECT INFORMATION Site Address: f8Ct25 ~{~ cJ Assessor's Parcel Number:-------- Emergency Contact: Name: U e2£.lC A +-k?,.e,r 24 Hour Phone:' ]~(J -SCX)'=LJ 33 Construction Threat to Storm Water Quality (Check~oy ~MEDIUM O LOW Q) ..... CJ) 0 ;:: ..... C: CJ) Q) ::, E 0 Q) ~ O> o0 N C: 00 :c ::::!e tO I ::;. 3: Q) ..... CJ) 0-+-' 3: C: Q) Q) E ..... Q) Q) O> bo C: C: oo O::::!e co I i Page 1 of 1 REV 11/17