Loading...
HomeMy WebLinkAboutCDP 2020-0001; PATEL RESIDENCE; STRUCTURAL CALCULATIONS, PROPERTY LINE WALL; 2020-11-13 STRUCTURAL CALCULATIONS ______________________________________________________________________________ ______________________________________________________________________________ NEW RESIDENCE FOR MR. RAJ PATEL PLAB CHECK CORRECTIONS FOR PROPERTY LINE WALL 11-13-2020 5462 A and B CARLSBAD BOULEVARD CARLSBAD, CALIFORNIA 92008 ______________________________________________________________________________ ______________________________________________________________________________ NOVEMBER 13, 2020 John W. Starlin, S.E. Structural Engineering 197 WOODLAND PARKWAY, #410 SAN MARCOS, CA 92029 Phone (619) 840-7990 Email: engrjack@cox.net I L I Cantilevered Retaining Wall JOHN W. STARLINLic. # : KW-06000908 DESCRIPTION:Property Line Wall Plan Check Responses 11-13-2020 Title Block Line 1 You can change this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Title Block Line 6 Software copyright ENERCALC, INC. 1983-2020, Build:12.20.5.17 File: Patel.ec6 Project Title:Engineer:Project ID: Printed: 13 NOV 2020, 1:27PM Project Descr: Calculations per ACI 318-14, TMS 402-16, IBC 2018, CBC 2019, ASCE 7-163.00 5.00 0.00 6.00 2,000.0 35.0 0.0 35.0 psf/ft 300.0 Criteria Soil Data Retained Height =ft Wall height above soil =ft Heel Active Pressure =psf/ft: 1Slope Behind Wall Height of Soil over Toe = in Water height over heel =ft pcf pcf=110.00 = 110.00 = Soil Density, Heel Toe Active Pressure = Passive Pressure =psf/ft Allow Soil Bearing =psf Soil Density, Toe Soil height to ignore Friction Coeff btwn Ftg & Soil =0.350 Vertical component of activeLateral soil pressure options: NOT USED for Soil Pressure. NOT USED for Sliding Resistance. NOT USED for Overturning Resistance.for passive pressure =12.00 in Equivalent Fluid Pressure Method Surcharge Loads Adjacent Footing Load 0.0 Lateral Load =130.0 plf 0.0 0.00.00.0 Axial Load Applied to Stem Wall to Ftg CL Dist =0.00 ft Wind on Exposed Stem psf25.0= Lateral Load Applied to Stem Surcharge Over Heel =psf Adjacent Footing Load =0.0 lbs Axial Dead Load =lbs Footing Type Line Load Surcharge Over Toe psf Footing Width =0.00 ft...Height to Top =3.00 ft Eccentricity =0.00 in...Height to Bottom =0.00 ft Used To Resist Sliding & Overturning Used for Sliding & Overturning ==0.0 ft Axial Live Load = Base Above/Below Soil lbs = Axial Load Eccentricity ==Poisson's Ratio 0.300 at Back of Wall in Design Summary Wall Stability RatiosOverturning =3.45 OKSliding=2.62 OK Total Bearing Load =2,559 lbs...resultant ecc.=0.99 in Soil Pressure @ Toe =563 psf OKSoil Pressure @ Heel =461 psf OK Allowable =2,000 psfSoil Pressure Less Than Allowable ACI Factored @ Toe =675 psfACI Factored @ Heel =553 psf Footing Shear @ Toe =6.2 psi OK Footing Shear @ Heel =0.0 psi OK Allowable =75.0 psi Sliding Calcs (Vertical Component NOT Used) Lateral Sliding Force =799.4 lbsless 100% Passive Forceless 100% Friction Force Added Force Req'd....for 1.5 : 1 Stability =0.0= 895.70.01,200.0== 0.0 -lbslbs lbs OK lbs OK - 2nd Stem OK3.00 Masonry12.00#532.00 Edge 0.160 125.0 312.5 1,957.8 1.2 38.7 133.09.00 30.0030.0030.00 1,500 24,000 YesYes21.481.000 11.60 3rd Stem OK0.00 Masonry12.00#516.00 Edge 0.449 668.1 1,429.3 3,183.7 6.2 38.7 133.0 9.00 30.007.007.00 1,500 20,000 YesYes21.481.000 11.60 Masonry Block Type =3 Stem Construction Top Stem Stem OKDesign Height Above Ftg =5.50ft Wall Material Above "Ht"=MasonryThickness=12.00inRebar Size =#5Rebar Spacing =32.00in Rebar Placed at =CenterDesign Data fb/FB + fa/Fa =0.063 Total Force @ Section =62.5lbs Moment....Actual =78.1ft-l Moment.....Allowable =1,232.0ft-l Shear.....Actual =0.9psi Shear.....Allowable =38.7psi Lap splice if above =30.00in30.00inHook embed into footing 30.00=in Wall Weight =133.0 Lap splice if below = psf Rebar Depth 'd'=5.75in Masonry Dataf'm =1,500psi Fy or Fs =psi 24,000 Solid Grouting =Yes Modular Ratio 'n'=21.48Short Term Factor =1.000 Equiv. Solid Thick.=11.60in Masonry Design Method ASD= Load FactorsDead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.600 Seismic, E 1.000 Cantilevered Retaining Wall JOHN W. STARLINLic. # : KW-06000908 DESCRIPTION:Property Line Wall Plan Check Responses 11-13-2020 Title Block Line 1 You can change this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Title Block Line 6 Software copyright ENERCALC, INC. 1983-2020, Build:12.20.5.17 File: Patel.ec6 Project Title:Engineer:Project ID: Printed: 13 NOV 2020, 1:27PM Project Descr: 4.00 1.00 18.00 12.0012.00 =Min. As %0.0018 Footing Dimensions & Strengths f'c =2,500psi Toe Width =ftHeel Width = Key Distance from Toe Key DepthKey Width =in=in =4.00 Footing Thickness =in 5.00= ft Cover @ Top =2.00 in@ Btm.=3.00 in Total Footing Width =150.00pcfFooting Concrete Density Fy =60,000 psi Footing Design Results Key: = Not req'd, Mu < S * Fr Factored PressureMu' : UpwardMu' : DownwardMu: Design Actual 1-Way ShearAllow 1-Way Shear Toe:Not req'd, Mu < S * FrNot req'd, Mu < S * Fr =None Spec'd == = == 675002,287 6.1775.00 Heel: 553000 0.000.00 HeelToe psfft-lbft-lbft-lb psipsi Heel Reinforcing =# 5 @ 16.00 in Other Acceptable Sizes & Spacings Key Reinforcing Toe Reinforcing =# 5 @ 16.00 in Summary of Overturning & Resisting Forces & Moments .....RESISTING..........OVERTURNING.....Force Distance Moment Distance MomentItemForce Soil Over Heel ft-lb 354.4 lbs 531.6 -70.0Toe Active Pressure 1.50 5.00 ftft =Heel Active Pressure ft-lblbs Sloped Soil Over Heel = =Surcharge over Heel = Surcharge Over Heel = = Adjacent Footing Load =Adjacent Footing Load Axial Dead Load on Stem = =* Axial Live Load on Stem Soil Over Toe Surcharge Over Toe Surcharge Over Toe Load @ Stem Above Soil =125.0 7.00 875.0 = = 0.67 -46.7 220.0 2.00 440.0= = = Stem Weight(s) = 1,064.0 4.50 4,788.0 Earth @ Stem Transitions =Footing Weight = 1,125.0 2.50 2,812.5 Key Weight = 150.0 4.50 675.0 Added Lateral Load lbs =2,529.9 Vert. Component Total = 2,559.0 390.0 3.00 1,170.0 8,715.5* Axial live load NOT included in total displayed, or used for overturningresistance, but is included for soil pressure calculation. Total =R.M. =799.4 O.T.M. = Resisting/Overturning Ratio =3.45Vertical Loads used for Soil Pressure =2,559.0 lbs 25.psf 130.psf Pp= 1200.# 799.38# 562.65psf 460.95psf #5@16.in @ Heel 2" 3" #5@16.in @Toe 3" 3" Designer select all horiz. reinf. 12.in Mas w/ #5 @ 32.in o/c Solid Grout 12.in Mas w/ #5 @ 32.in o/c Solid Grout 12.in Mas w/ #5 @ 16.in o/c Solid Grout 6" 1'-6" 1'-0" 2'-6" 2'-6" 3'-0"3'-0" 5'-0" 8'-0" 4'-0"1'-0" 4'-0"1'-0" 5'-0" • • 7 _j_