Loading...
HomeMy WebLinkAboutDWG 351-5L; CUP 96-08; CONTRACT SERVICES; 01.0 rlo/ PRINTED ON CLEARPRINT 1000H \ \ ~ ./ ··~'STI~ ~A-!AL-T f,AVGi--.;;; ~ ~t-6 l..07 I 1 • l PLANTING I. Container grown plants to be planted in plant pits (2) times wider than plant · containers and a depth of (1-1/2) times the height of plant containers. Unless noted otherwise, plant crown to be slightly higher than its natural growing height after settlement. ~ 2. All plants shall be watered immediately before backfilling planting pits. 3. All areas receiving plants shall be moist to a depth of 6" at time of planting. 4. Use 'Agriform', 20-10-5:21 gram tablets per manufacturer's specifications, with all shrubs and trees. 1 per liner or I gallon, 2 per 5 gallon, 3 per 15 gallon and 4 per foot of box width. 5. Provide (1) 'Agriform' 20-I0-5 fertilizer tablet with each flatted plant -5 gram size. 6. Plant all plants 5' minimum from irrigation heads (slopes only). 7. Scarify the sides of each root ball prior to planting if circular root growth is evident. 8. Plant quantities on the plant list are for the contractor's convenience and not guaranteed to be accurate. 9. Plan symbols take precedence over quantities specified. 10. Soil test required to determine soil amendments, fertilizer, and backfill. The City of Carlsbad Inspector shall approve soil test recommendations. 11. All landscaping shall be constructed according to these approved plans, and all landscape areas shall be maintained in a healthy and thriving condition, free from weeds, trash, and debris. SOIL PREPARATION I. The following shall be applied per 1,000 sq. ft. of planting ~rea and tilled into the soil to a depth of6": (excluding slopes) 2. yds. a. Nitrolized wood shavings 3 cu. yds. b. 12-8-8-gropower 200 lbs. c. Agricultural gypsum 200 lbs. Backfill for all shrubs and trees shall consist of the following materials per IO cu. a. b. C, On site soil Nitrolized wood shavings 12-8-8 gropower IRRIGATION 6 cu. yds. 4 cu. yds. 50 lbs. I. The irrigation system is existing and fully operational in all landscaped areas. Therefore, there are no new irrigation drawings. ' J....._ ' ' .. ; . . \ . . ) ) f;J(;l,lc:.i;;'I', C:~S' '' . 0 . ,' .. Hose: Loop shall be 1" ~rut1r in di1m111r 1h1n tne trunk ' 2 st1k11 Ind 2 tiu. TI, tnt trunk 6" abovt bending momtr:,t of tr11. Tl■ should provide flaxibility of 1runk but not allow rubbin9 ' . ~ Pl.AN PI.ANT SPECIES QIJANIIIY A. B. C. D. E. F. G. H. I. J. K· Existing Tree Existing Shrub Existing GroWidcover(F!e,::, !'f'f'LS) Melaleuca Nesophila (pink melaleuca) Nerium Oleander (oleander) Pinus Halepensis ( aleppo pine) Pinus Canariensis ( canary island pine) Pinus Radiata (monterey pine) , Schinus Terebinthifolius (brazilian pepper) Delosperma 'Alba' (white trailing iceplant) Existing Vines 29 33 4 3 3 7 flats OWNER: Trapiks Inc. ARCHITECT: 'po Box 188280 Carlsbad, Ca. 92008 tel: 619-931-6805 Edward Ebright 1991 Village Park Way Encinitas, Ca. 92024 tel: 619-942-1021 2" Mutth .~:.::;>,,._~--Preparld Sail Mix------,,, x 1!111 widlh min ~ .. ,<----Plant Tab par1d sail mix, puddl1 and saltl• prior la setting lrN. Sarity soil, add 1q111I amount pr1pand soil ■nd thoroughly milC. 2 x 1!1■11 width mm • N !. TREE PLANTING . SLOPES TREE PLANTING • LEVEL GROUND SIZE 5'gal. 5 gal. 15 gal. 15 gal. 15 gal. G" oc. GENERAL NOTES -··1· L I of trunk aoai.-n stakt. Cuc stakes off S" abovt tia. For singl1 dab tnn, plaet 111kt an windward sidt of rm, ------...J TREE STAKING -LEVEL GROUND SWTH STATE BEAOI ... ... " .._ I , . " I I. NO IRRIGATION PLAN IS REQUIRED BECAUSE THERE IS AN EXISTING SYSTEM FOR ALL EXISTING AND PROPOSED PLANTING. 2. The contractor must notify the City Plan Check Consultant (619-438- 1161 ext. 4221) 72 hours (three working days), prior to starting construction. 3. The landscape or irrigation contractor is to verify existing P.S.I. at job ENGINEER'S SIGNA nJRE REQUIRED ON PAGE 1 ONLY APPROVED APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING ·PRECISE LOCATION OF PLANTING AREAS. site prior to installing landscape irrigation system. Verification shall be made with the appropriate water district. 4. All reduced pressure backflow preventers shall be tested after installation relocation, or repairs by a City approved certified tester. Call 438-2722 ext. 152 for a list of City approved certified testers. Developer/owner is responsible for snpplying a copy of the test results to CMWD at 5950 El Camino Real. 5. Low head drainage is not permitted. Add check valves as needed to prevent Jow head drainage. 6. Popups must be used within 10 feet of all pedestrian uses. 7. The Contractor is responsible for obtaining building and plumbing permits prior to commencing on any wall construction and irrigation installation. respectively. ASSIST TITLE , ... fCI III'30I REVIEVED BY, INSPECTOR DATE DATE 8. Irrigation systems for individual parcels shall have points of connection INITIAL DWN BY: ---'-PROJECT NO. DRAWING NO. for the system between the water meter and water service riser into building and ahead of any water regulation device installed for buildin . .. ENGINEER OF WORK REVISION DESCRIPTION DATE INITIAL □THER APPROVAL DATE INITIA,L CITY APPROVAL CHKD BY: __ _ RVVD BY• cur> q;;;;,-~-·.ei?J;_sc· REVISIONS BY DRAWN Cl-ll!CKED DATE ■CAL■ JD ■ ND. BHl!ET, D .. ■Hl!l!TS I \ ' i