Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DWG 352-3L; HDP 96-14; TAYLOR MADE GOLF; 01-12
---------------------------------------------------------------,a-,,•,•,--,•-~-.,•-~-------------------------,----, ~le:~le:fPsb.\lL ~Of~$: RECLAIMED 'WATER NOTES: ill.L WORK SHALL BE DONE IN ACCORDANCE WITH THE CARLSBAD Ml"~JICIPAL WATER DISTRICT'S "CARLSBAD RECLAMATION RULES & REGU ATIONS FOR CONSTRUCTION OF RECLAIMED WATER M,I\INS' DATED OCTOBER, 1993 2 CR INK I ~G FOIJ~ TA I NS SHALL BE PROTECTED FROM SPRAY OF RECLA: MED WAT~R. BEST MANAGEMENT PRACTICES SHALL BE USED TQ MINIMIZE RECLAIMED WATER E~CRCACHMENT ON PUBLIC FACILITIES SUCH AS PICNIC TABLES. BBQ' S, PLAYGROUNDS, SAND TOT LOTS, ETC SIGNAGE NOTES: ' 3. BEST MANAGEWENT POACTiCES SHALL BE USED TO ELIMINATE OR CONTROL ro THE BEST EXENT POSSIBLE PONDING. RUN-OFF, OVER••SFRAY IND MISTING. 4 HOSE BIBS ARE STRICTLY PROHIBITED. 5. ON-SITE CROSS-CONNECTIONS BETWEEN c;:E:CLAIMED WATER LINES AND POTABLE WATER LINES !S STRICTLY PROHIBITEC. 5, NO SUBSTITUTION OF PIPE MI\TERIALS WILL BE ALLOWED WITHOUT P'<IOR APPROVAL OF THE CITY OF CARLSBAD MUNICIPAL WATER DISTRICT 7 AL~ ON-SITE PIPES SHALL HAVE WARNING TAPE PER CARLSBAD "1UNICIPAL WATER DIS IRICT'S RLLES AND REGULATIO~S 8 THE IRRIGATION SYSTEM S--IALL RUtl BETWEEN THE HOURS OF ID: 00 PM. A,\JD 6: 00 AM, THE FOLLOWING MORNING (SPOT IRRIGATION COULD B~ DONE AT A DIFFERENT TIME) WITH OUA_IFIED SUPERVISION PE'lSO"JNE_ ON SITE 9 PROVIDE A MINIMUM OF AT LEAST 18 ltK--IES OF COVER OVER ALL WIRING AND PIPING, IC. ~ON-DESIGNATED USE AREAS SHALL B~ PROTECTED FRCM CONTACT WITH RECLAIMED WATER, WHETHER 3Y WINDBLCWN SP'lAY OR BY CIRECT APPLICATION THROUGH IRRIGATICN OR OT~ER USE LACK OF PPCTECT I 0'1, WHE-HER BY DES I Gfl, C•)NSTRJCT I ON PR ACT I CE OR SYSTEM OPERATION. IS STRICTLY PROHIBITED. 11 IRRIGATION HEADS SHALL BE ~ELOCATED OR ADJUSTED TO PREVENT OVE'l-SPPAYING ON SIDE'NALKS, STREETS, AND NON-DESIGNATED USE ARE.AS 12. RECLAIMED WATER OUICK COLPLING VALVES SHALL 3E OF A TYPE DESIGNED 0 0R USE ON RECLAIMED WATER DISTRIBUTION SYSTEijS (SPIKES NOT INTERCHANGEABLE WITH POTABLE WATER QUIC~ CJUPLER SPIKES) PER CARLSBAD MUN:CJPAL WATER DISTPIC S RULES AND ,EGUUliONS 13 METERS SHALL BE SIZED BY THE CITY OF CARLSBAD MUNICIPAL WAT[R CISTRICT. 14. ALL IRRIGATION PIPES SHALL BE STENCILED WIT--1 THE WARNING "NON-POTABLE OR RECLAIMED WATER", COLOR-CODED (PURPLE) AND LAID WIT~ WARNING TAPE AND STENCILING CRIENTED TOWARD THE TCP OF THE TRENCH PER THE CITY OF CAQLSBAD MUNICIPAL WATER DISTRICT'S RULES AND REGULATIONS. 15 ALL POTABLE WATER AND RECLAIMED WATER RIPING SHALL BE INSTALLED WITH THE STENCILING ORIENTED TOWARD THE TOP OF T-,E TRENCH. 16 WHEN A POTABLE WATER LINE AND RECLAIMED WATER LINE CROSS. THE RECLAIMED WATE'l LINE SHALL BE INST°'LL~O WITHIN .A PROTECTIVE SLEEVE THE SLEEVE SHALL EXTEND 10 FEET FROM E/ICH SIDE. FROM THE CENTER LINE OF THE POTABLE LINE. FOR A TOTAL OF 20 FEET 17. A 10 FOOT HORIZONTAL SEPARATION BETWEEN POTABLE WATER ANO RECLAIMED WA,TER MAINS MUST BE "1A :-.JTAINED AT ALL TIMES, THE POTABLE WATER LINE MUST BE: INSTALLED ABOVE THE RECLAIMED WA !ER L'NE 15. A MINIMUM OF 12 INCHES OF VERTICAL SERAR,A70N BETWEEN i,;TILITIES MUST BE MAINTAINED AT ALL TIMES THE FOLLOWING GUIDELINES FOR Tf'E USE OF RECL!,IMED WATER ARE TO BE PERMANENTLY POSTED INSIJE THE DCOR Or EACH CCJrHROLLER WHERE THEY ARE EASILY VISIBLE PLACE ON AN 8-1/2'' x 11' SIZED SIGN COLOR PURPLE BACKGROUND WITH 3LACK LETTERING GUIDELINES FOR RECLAIMED WATER USE: 1. IRRIGATE BETWEEN ,HE HOURS ~IF IO PM. AND 6 A It CNL Y WA-ERING OUTSIDE THIS TIME FR~ME MUST BE DO~E ,IANLALLY WITH A QUALIFIED SIJPERVISORY PERSONflEL ON-SITE. NO SYST:':M SHALL AT ANY -IME BE LEFT LNATTENDE) DLRING USE OUTSIDE THE fJOR~AL SCHEDU_E 2. IRRIGATE IN A MANN[R THAT WILL MINIMIZE RU~-OFF. POOLING AND PONDI\IG. fHE APPLICATION RA TE SHALL NCT EXCEED THE ltJFIL -RA,TION RATE OF THE SOIL, TIMERS Mi.,ST BE ADJUSTED SI) AS TO BE OMPATIBLE WITH THE LOWEST SOIL !~FILTRATION RA-E PRESENT ~HIS PROCECURE MAY BE FA.C:LITATEO BY THE EFFICIENT SCHEDUL1NG OF THE ·°'UTOM,ATIC CONTROL CLOCKS, ( c. EMPLOYING THE REPEAT FUNCTION TO BRE:AK UP THE TOTAL IRRIGATION TIME INT:) CYCLES THAT WILL PROMOTE MAX MUVI SOIL ABSCR~TICN), 3 AO.llaST SPRAY HEADS TO ELIMINATE 0\/E:RSPRAY ONTO AREAS ~OT UNDER ""HE CONTROL OF THE CUSTOMER FOR EXAIAFLE, POOL DECKS, PRIVATE PATIOS AND LOTS, ,AND STREETS AND SIDEWALKS. 4 MONITOR AND MAINTAIN THE SYSTEM TO MINIMIZE EOUIPME:-J~ AND MATERIAL FALURE BROKEN SPRINKLER ~EA)S, L,:.AKS. UNRELIABLE VALVES, ET:: SHOULD BE REPAIRED AS SOON AS THEY BECOME: APPARENT, 5 EDUC.ATE ALL MAINTENANCE FERSONNEL, ON A CONTINUING BASIS, 0° THC: PRESENCE OF RECLAIMED WATER ~ERSONNEL MUST BE INFO'lME) TH.AT R.C WATER IS M[A\JT FOP. IRRI. PURPOSES ONLY, Ar,o IS NO-APPROVED FOR DR/\IKING PURPOSES. HAND, TOOi., WASHlfJG, ~TC GIVEN H-E HIGH TUP.NO\/ER RATE OF EMFLOYEES 1,1 Tf-iE L.A~DSCAPE l~OUSHY. ,TIS IM"ORTANT THAT THIS NFORMATIO'I BE DISSEMlt<ATED 0~ AN ALMOST DAILY BASIS. IT IS YOU, 'HE LM]DSCAPE cornR.ACTOR, WHO S RESPONSl3LE FOR EDUCATING EACH AND EVEPY ONE OF YOUR EMPLOYEES. 6 OBTAIN PRIOR APPROVAL OF ALL RRO~OSED iHANGES AND IAODI FICA ~IONS TO ANY "RI\/ A TE ON --SI TE FACILITIES SUCH ::'HAflGES ~IUSl BE Si)BMITTED Ti), AND APPROVE[' BY, THE )!STRICT ENGINfERING OFFICE AND DESIGNEC IN ACCORDMJCE WITH DISTRICT STA'JDARDS 7 ALL RECLAIMED W~TER SPRINKLER CCNTROL VA,LVES SHALL BE 'AOGEC WITH IDENTIFICATION TAGS A TAGS SH,AL_ BE WEATHERPROOF Pc.AS TIC, 3" X 4", PURPLE IN COLOR ll'TH "HE WORDS "WARNING RECLAIMED WATER -DO NOT DRINK .. IMPRI~ TED ON OtJE SIDE AND ":AYISO -.AGUA IMPURA -NO TOMAR' CN THE OTHER SIDE. IM 00:NTING SHALL 3c PERMANENT 3LACK IN COLOR, USC: TAGS AS IAANUFACIURED 3Y I. CHRISTY ENTERPRISES OR APPROVED EQUAL. B DNE TAG SHAL .. BE ATTACHED TO EACH VALV:. AS FOLLOWS: ATl~CH TO VAcVE STEM DRECILY OR \\1Tfi PLASTIC TIE-WRAP OR. 2 ATTACH TO SDLE:fJOID WIRE DIRECTLY OR WITH PLASTIC TIE-WRAP OR: .3. ATTACH TO VALVE COVER WITH EXISTING VALVE COVcR BOLT. 8 ALL SPR NKLER HEADS SHALL BE IDENTIFIEJ AS RECLAIMED WATER SPRINKLER HEADS '19 DEVELOPER/CONTRACTOR SHA.LL CONDUCT A CROSS-CONNECTION II TEST AND COVERAGE TEST AS DIRECTED BY THE CARLSBAD MUNICIPAL ' EACH AUTOMATIC CONTROLLER AND IT'S ASSOCIATED EO:JIPf.lENT SHALL BE l)ENTIFIED WITH A SIG~I EEARING THE WCRDS '"RECL,AIMED WATER USED FOR IRRIGATIO~' IN ENGLISH AND SPANISH, WITH 8LACr: LETTERS I INCH HIGH ON A PU.RPLc 3ACKGROUND THE SIGN S~ALL BE PLACED SO THAT IT CAN BE RcACILY SEEN BY ANY OPERATIONS PERSONNEL UTILIZifJG THE EOUIFMENT WATER )!STRICT C:NGINEER AND/OR -HE SAN DIEGO COUNTY DEPART- MctH OF ENVIRONMENTAL HcALTH PRIOR -c ANY JSE OF RECLAIMED WATER 20. QUICK COUPLING VALVES USED IN RECLAIMED WATER SYS 7 Etv'S SHALL CONFORM TO THE FOLLOWING RE,:LAIMED WATER-OUIC< COUPLlf'.G VALvES UScD IN '<ECLAIMEO WATER SYSTEMS SHALL HAVE ACME -ypE THREADS ,ANO PL.RPLE COLORE) LOC~.ING :::OVERS PE'ltv'ANENTLY ATT°'CH~D TO T--IE VALVE (SPIKES NOT INTEP.CHANGE:ABLE WITH POTABLE WAT[R OUJ:::K cou~LER SPIKES) QUICK COUPLING VALVES SHALL BE NELSON NO 7645. HUNTER NO HVJOOA-RL-NP OR APPROVED EOLA_ 21 AN AN'JUAL CROSS CONNECTION INSRECT!ON WILL BE DONE BY EITHER CARLSBA) MUNICIPAL WATER DISTRICT OR SAN DIEGO COUNTY DEPARTMENT OF EN\IIC:ONME'JTAL HEALTH COPIES OF INSPECTION REPORTS WILL BE FORWARDED TO TH:: NON- INSPECTING PARTY *22. DEVELOPER SHALL SHOW THE LOCATION OF RC SIGNS "00 NOT DRINK'' ON THESC: PL/.NS *23 ,AN ON-SITE: USER/SUPERVISOR SHALL BE DESIGNA-ED IN WRITING THIS NDIVIDUAL 5:--1ALL BE FAMILIAR WITH "LUM8ING SYSTEMS 'MTcllN THE PROPERTY, WITH THE BASIC CONCEP-S OF 8ACKFLOW/CROSS- CONNECTION, AND THE s0 ECIFIC REOUIREMEN rs OF A RECLAIMED WATER SYSTEM COPIES OF THE DESIGNATION, WITH CONTACT PHONE NUMBERS SHALL BE PROVIDED TO THE SAN DIEGO CCUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH ANO CARLSBAD MUNICIPAL WATER DISTRICT. IN CASE OF EMERGENCY CONT.ACT BILL DETTENBORN (619) 603-6034 OR AFTER HOURS CONTACT: BILL DETTENBORN (619) 603-6034 • ITE:MS NOS. B. 19. & 23 SHALL BE REQUIRED JUST PRIOR TO THE ACTUAL USE OF RECLAIMED WATER, ITEM NO, 22 THE SIGNAGE PLAN SHALL BE A PART OF THIS IP BUT THE ACTUAL SIGNS AND TABS WILL BE INSTALL::D JUST PRIOR ~o ACTUAL USE OF RC WATER 24. SHOW ALL PUBLIC & PRIVATE POTABLE WATER MAINS ON THE IMPROVEMENT PLANS. 25 ON RECLA I MED WATER SYSTEMS. ALL APPURTENANCES ( SPR INK- LER HEADS, VA~VE BOXES, ETC,) SHALL BE COLOR-CODED PURPLE PER AWWA GUIDELINES AND SECTIO~ 4049, 54 OF THE CALIFORNIA HEALTH AND SAFETY CODE, I ,--~------- t V) '.:' f-- z WARNatQ RECLAIED WATl!ft DO NOT DRINI( AY'8O -AQUA IIIIIPUlllA NO TOMA.A 18" X 18" SIZE 016 ALUMINUM, Cl6C ABS PLASTIC OR STIC~-ON VINYL SIGNS ~BLACK LOGO I ,.....--PURPLE BACKGROUND II I ,1 BLACK LETTERS 36" / / (N TS ) I (SIZE) 12" X 36" 060 ABS RLAS Tl C OR STICK-ON VINYL \..._ 1. BLACK LETTERS ~--z· SLACK LETTERS SIGNS ALSO, ,016 ALUMINUM ~~~l~~M~[D) W ~ f~~ @>)f@>f~M (f)~~~ £1F~l lJ&Wl©~ ~£[Q)~ ~(Q)[L[p co 0) C•> ~£~l®@£~ ~~®~~~~~ ~~~1~~ ~£~l~lID~[Q)9 ~£l~f ©~~~£ flTI_E SHEET. RECLAIMED VVA,TER r~OTES IRR G.ATIOl'J ,~: LA.f\lDSCAPE SPECIFICA TIDl'JS IRR CATION PLAr~ 1 2 THRDUGH 5 6 THROUGH 8 9 THROUC;f-i 1, 1 2 0 LEGEND --....cw---- --RC-- --RC-N llil) POTABLE NATER SYSTEM PROPOSED RECLAIMED WATER SYSTEM AREA OF REC_A]MED WATER USE LOCATION OF CONNECTION POINTS METER & 8ACKFLOW PREVENTJCN CTI ---+--- ----f'---- "DO NOT DRINK" SIGN LOCATIONS EXISTING POTABLE IRRIGATION SYSTEM ROTAB_E F'RE MA:NLINE SEWER SYS-EM INSPECTION PROCEDURES: 1 CITY CONSTRUCTION INSPECTION SHALL INCLUDE: A LOCATION OF FIRE LINES. B TRENCH DEPT--!, C REQUIRED ·SEPARATION (HORIZONTALLY ANO VERTICALLY) D PIPE IDENTiFICATION E POINTS-OF-CONNECTION (PO C'S) F LOCATION AND IDUJTIFIOATION OF SPRINKLER HEACS G WAR"JING SIGNS AT THE SITE ANO ON THE TRUCKS HAULING RECLAIMED WATER (IF RcCLAIMEC WA ER IS USEC FOR CONSTRUCTION) AN A"PROVAL LETTER REGARDING THE INSPECTION OF TrE PROJECT SHALL BE OBTAINED FROM THE CITY AND THE CISTR•CT, AND BE FORWARDED TO THE COUf.TY DEP.ARTMENT OF ENVIRONMEN~AL HEALTH PRIOR TO THE .0 INAL NSPECTION APPROVAL. 2. DISTRICT FINAL INSPECTION SHALL INCLUDE: A. COVERAGE EST, AFTER COMPLE-I0~ OF THE SPRINKLER SYSTEM. TO DETERMINE THE .ADEQUACY OF COVERAGE ON THE APPROVED USE AREA ANO PROTECTION OF AREAS NOT APPROVED FOR RECEIVING RECLAIMED WATER, B WAPNING SIGNS AND LABELS C OUICK COUPLING VALVES D ALL ASPECTS OF Tc!E IRRIGATION CONDITIONS I1-;CcUDING WINDBLOWN SPRAY, RUNOF'". AND POND NG. E REOUIRED PROTEC-ION OF ALL RESIDENTIAL AREAS F. REOUIRED PROTECTION OF ALL WELLS, STREAMS. RE:SER\IOIRS, ETC.. G CROSS-CONNECTION .3 ANNUAL INSPECTION SHALL INCLUDE: A COMR~ETE INSPECTION SHOULD COVER PART A AND PART 8 AND PART G OF THE DISTRICT FINAL INSPECTION DECLARATION OF RESPONSIBLE CHARGE: EXFIRATIO~ I HEREBY DECLARE THAT I AM -HE LICENSED DESIGNER OF WORK FOR THIS PROoECT. THA ~ I H,AVE EXERCISED RESPONSIBLE CHARGE 0\/ER THE DESIGN OF THIS 0 ROJECT AS DEFINED IN SECTION 6 703 OF THE BUSINESS A,JD PROFESSIONS CODE AND THAT THE DESIGN IS CONSISTE'JT WITH CURRENT STANDARDS I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIO\JS BY THE CITY OF CARLSBAD AND THE S.AN DIEGO COUNTY DEPARH-1ENT OF E'JVIRONME~ TAL HEAL TH. IS CONFINED TO A REV:EW ONLY N,D DOES NOT RELIEVE ME, AS Tr'E L'CENSED DESIGNER OF WORK, OF MY RESPONSIBILI-IES FOR PROJECT DESIGN. THESE PLANS HAVE BEEN PREPAR~) IN SJBSTANTIAL CONFORMA.\JCE WITH THE APPROVED LANDSCAPE CONCEPT PLAN. WATER CONSERVATION PLAN, FIRE PROTECTlm, PLAN, AND ALL CONDITIONS OF A"PROVA_ RELATED ~o LANDSCP~ () I 'JA II BY f.&= ~ 1/J,. DATE 6·11) ''lf KIM ROY WILEY Landacap• Architecture ~i> Wiley Group Kim Roy Wiley, A.S.L,A. 868C: Novojo Rd Ste 102-103 619/593-2522 Londsc:o;:,e Architect San )iee;o, Cfa. 92·119 CA LIC # ·1359 HAMANN CONSTRUCTION ADOR[s~;: 475 W. BRADLEY AVENUE EL CAJON, CAL IF ORN I,~ 92Ql0 DRAWN 9Y KW SCALE· AS NOTED C:A~LSBAO M,JHICIPAL WA.TE~ DISTRIC- ,,.,..k'I,,; f.._'E4i!!!"I,,. __ WILLIAM [. PLUM,IER DISTRICT LNGINlEP RC E. 28 76 'ciAN OIEGJ CGIJNTY DEPARTMENT OF ENVl'lO"'lc,TAL HEALTH DATE. 3/37/98 CHECKED 8Y: ~W DATE: PLAI', TING Pl .. !,N I RR G.A Tl Ol'J &: P LAI', Tl i'J G DE TA LS REVISIONS MUST BE APPROVED BY PUBL:C HEALTH ENGINEER, ASS-PLA~NIN~ DIREC-OR & DISlRICl E~GINEER PRIOR TO l~PLEMENTATION IN~IELD E E REQUIRED ON PAGE 1 m,u I '3·l0·97 DATE PROJECT SITE f-'AL.<_lM/,=i ··\> ·'i'.-' APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS NOT TO SCALE "AS BUILT" Ki t-1 W i L--?-7 e I z.:i/ o/2 NA Mt DATE: TITcE ? # OSCA fe, /Jl:z::/lj{k,.7 REVIEWED BY: L.§il_~ INSPf;CTOR ---------t------t---+-------+------t I SHElET I .I __ C_I_T_Y_O_F_C_-_A_R_L_S_B_A_D __ I r SH1EE2TS _ PLANNING DEPARTMrnT " DATE INITIAL DATE INITIAL Rc\llSION DESCRIPTION ENGINEER OF WCRK OTHER APPROVAL CITY APPROVAL PRIVATE (ONSITf-f RECLAIMED WATER SYS EM FOR: TAYLOR MADE GOLF CARLSBAD RESEARCH CENTER CARLSBAD. CALIFORNIA APPROVE~~,: . . IJ . -· / pr, . .· '?,J.-,,..q.(_,, ASSiSTANTLANN,NG DIRECTOR . DWN BY: CHKD BY: ___ _ RVWD BY: .,_,.,~ .. ·--·-·'--- PROJECT NO. HDP96-14 C.M W.D JOB NO. _9_6_-_2_4_4 _____ _ /f_?---77 DATE DRAWING NO. 352-JL ( NOTE· C M W D SPECIFICATIONS_T_AKE:_ PRECEDENCE.) IRRIGATION SvSTEM GENERAL CONDI-IONS OF THE CONTRACT APPLY TO THIS SEC-ION AS T~OJGH WRITTEN HEREIN sco~E OF THE WORK INCL.JDES ALL LABOR, MATERIAL'S, EOU!RMENT, ACCESSORIES, TR.~NSPORTATION, PERMITS, FEES, SERVICES AND INCIDENTALS NECESSARY TO COMPLETE THE LANDSCAPE S~RI~KLER SYSTEM AS HEREIN SPECIFIED AND INDICATE) ON THE DRAW:N8S DIAGRAMMATIC PLANS ~op rHE PURPOSES OF CLEARNESS AND LEGIBILITY, THE SPRINKLER SYSTEM LAYOUT IS DIAGRAMMATIC AND THE CONT~ACTOR S~ALL CAREFULLY INVESTIGATE THE STRUCTURAL AND F 1 NIS~ED CONDITIONS AFFECTING ALL OF 715 WORK ANO PLAN HIS WORK ACCORDINGLY. FURNISHING SUCH ~ITTINGS, SLEEVES, OFFSETS, ETC., AS MAY BE REQUIRED TO MEET SIXH CCNJ!TIONS. THE WORK SHALL BE :NS-ALLED IN SUCH A MA~NER AS TC AVOID CON~L!CTS BETWEEN IRRIGATiON SYSTEMS, PLANTiNG, AND ARC7 I TECT JRAL FEATURES. WI TH THE LA,IDSCAP~ ARCH I TEC~' S APPROVAL, T~E CONTRACTOR MAY MAKE ADJUSTMENTS WHERE NECESSARY -c CONFORM TO ACTJAL FIELD CONDITIONS. SUCH ADJUSTMENTS WILL REQU:RE CCORDINATION OF THE INSTALLATION w:TH THE LANDSCAPE ARCHITECT Eu- WIL~ NOT EXCEED T~E SCOPE OF THE WORK CUTLINED IN THE DRAWINGS ANO THE SPECIFICATIONS. THE IRRIGATION SYSTEM SHALL BE OPERATIONAL, WITH UNIFORM AND ADEQUATE COVERAGE OF THE AREAS TO BE IRRIGATED, PRICR TO PLANTING, THE CONTRACTOR SHALL NOT WILLFULLY INSTALL THE IRRIGATION SYSTEMS AS SHOWN ON THE DRAWINGS W~EN IT IS OBVIOUS IN THE FIELJ THAT OBSTRUCTIONS, GRADE DIFFERENCES OR DISCREPANCIES IN AREA □:MENSIONS EXIST THAT MIGHT NOT HAVE BEEN CONSICERED IN ENGINEERING, SUCH OBSTRUCTION OR DIFFERENCES S~OULD BE BROUGHT TO THE ATTENTJCN OF THE LA~DSCAPE ARCHITECT, I~ THE EVENT THIS NOTIFICATION IS NOT PERFOR~ED, THE CONTRACTOR SHALL ASSJME FULL RESPONSIBILITY FOR ANY REVISION ~ECESSARY. ORDINANCES AND REGULAT'CNS ALL LOCAL. MUNICIPAL AND STATE _AWS, AND RULES AND REGULATIONS GOVERNING OR RELATING TO ANY PO~TION OF THIS WORK ARE HERE3Y INCCRPCRATED INTO AND MADE A PART o~ T7ESE SPECIFICATIONS. REOU:REMENTS OF THE DRAWINGS ANJ SPECIF!CAT!CNS. NOT CONFLICTING THEREWIT~ BUT EXCEEDING THE CODE REQUIREMENTS, SHALL GOVER~ PERMiTS AND LICENSES THE CONTRACTOR SHALL SECURE T~E REOWIRED LICENSES AND PERMITS INCLUDING PAYMENTS OF CHARGES ANJ FEES, GIVE REOU!RED NOTIC~S TO PUBL'.C AUTHORITIES, AND VERIFY PERMITS SECURED OP ARRANGEMENTS MADE EY CTHERS AFFECTING THE WORK OF THIS SECTION. SUBM:TTALS SUBM:T A LIST OF AL~ IRRI~ATJON EQUIPMENT TO BE USED, MANUFAC-lcRER' S B'l0C7URES, M.~ Ir,E:r,ANCE MA'JUALS, GUARANTEES ANO OPERATING INSTRUCTIONS WITH!~ THIRTY-FIVE ( 35) DAYS AFTER AWARD OF corHRACT, AND BE~ORE A'JY IRRIGATION SYSTEM MAT~RIALS ARE DELIVERED TC THE JOS SITE 'JO SUBSTITUTIONS WILL BE ALLOWED WITHOUT PRICR WR]TT~N APPROVAL BY THE LA~DSCAPE ARCHITECT ANO CITY INSPECTOR. DO NOT PERMIT ANY IRRIGATION SYSTEM COMPONENT TO BE BROUGHT ONTO THE U03 SITE UNI IL :T HAS BEEN AFPROVED BY THE LANDSCAPE ARCHITECT RECORD AND AS-BUILT DRAWINGS THE CONTRACTOR SHALL PROVIDE A COMPLETE .. AS-BUILT' RECORD SET OF BLlELINE P~!NTS WHICH SHALL BE COR~ECTED DAILY A~D SHOW EVERY CHANGE FROM THE ORIGINAL DRAWINGS AND SPECIF:CA-IONS AND THE EXACT LOCAT:ONS, SIZES AND KINDS o~ EJUIPMEN-. PRINTS FOR ThJS PURPOSE MAY BE OBTAINED FROM THE LANDSCAPE ARCH:TEtT AT COST. THIS SET OF DRAWINGS SHALL BE KEPT ON -HE s1-E A~D SHALL BE LSED ONLY AS A ~ECORD SET THE CONTRAC-OR SHALL DIMENSION FROM TWO PERMANENT POINTS OF REFERENCE (SI DEW.ALK OR ROAD I NTERSEC f IONS, ETC ) THE l,OCAT I 0~ OF THE FOL_OWING ITEMS I CO~NECTIONS -o EXISTING WATER LINES 2 ROUTING OF PRESSURE SUPPLY LINES 3. SPRl~KLER CONTROL. VALVES. GLOBE VALVES MID QUICK COUPLERS. 4 WIRING. CONTROLLERS AND ELECTRICAL SERVICES BEFORE THE DATE OF THE FINAL INSPECTION, -HE CONTRACTOR SHALL TRANSFER ALL INFORMATION FROM THE 'AS-BUILT'' PR;NTS TO AN OZAL:C SEF!A, PROCURED FROM THE LANDSCAPE ARCHITECT ALL WORK SHALL BE NfAT ANO SUBJECT TO THE APPROVAL OF TrlE LANDSCAPE ARCHITECT. DELIVERY OF THE SEPIAS WILL NOT RELIEVE THE C □N-RACT □R OF THE RESPONSIBL:TY OF FIJRNJSH!NC, REDU!RED :NFORMAT!ON THAT MAY BE OMITTED FR8M THE PRINTS. THE OWNER RESERVES THE RIGHT TO PR~PARE THE 'AS-BUILT" CHARTS, THE CONTRACTOR SHALL PROVIDE A SEPARATE COST TC THE OWNER FOR THIS SERVICE ~oR FINAL DETERMINATION OF COMPLETION. ''AS-BUILT" CRAW!~GS SHALL BE APPROVED BY THE LANDSCA~E ARCHITECT BEFORE CONTRO~LER CHARTS ARE PREPARED CONTROLLER CHARTS PREPARE CHART SHOWING THE VA~VES AND SPRINKLER HEADS SERVICED BY EACH CONTROLLER. THE C~ART IS TO 3E A REDUCED DRAWING OF THE ACTUA~ "AS-BUILT" SYSTE~ OF THE SIZE THAT WILL FIT INTO CONTROLLER AND READABLE WHEN REDLCED USE A DIFF~RE~T COLOR TO INDICATE THE COVERAGE FO~ EACH STATION THIS CHART SHALL BE APPROVED BY THE LANDSCAPE ARC~:TECT AND HERMETICALLY SEA~E □ BY PLASTIC. THIS SHALL THEN 3E SECURED TO THE INS:□E CF TH~ COVER. EQUIPMENT TO 3E =uRNISBED THE CONTRACTOR SHALL FJRNISH AS A PART OF THIS CONTRACT THE FOLLOWING I. TWO (2) SETS OF SPECIAL TOOLS REQUIRED FOR REMOVING, DISASSEMBLING AND ADJUS-ING EACH TYPE OF SPRINKLER. 2. TWO (2) FIVE FOOT VALVE KEYS FOR GATE VALVES. 3. TWO ( 2) KEYS FOR EACH AUTOMATIC CO•N-ROLLER. 4, QUICK COUPLER KEYS AND MATCHING HOSE SWIVEL ELLS. (MINIMUM OF I SET PER 5 OU!CK COUPLERS; #'"i~SM12 Pl:)1 1-20 SUBSTITUTION', (CITY !NSPEC_1:G._R_J.l_t,JST APPROVE AL;';_O) IF THE IRQ!GAT!ON CONTRACTOR WISH~S TO SUBSTITUTE ANY EQUIPMENT OR MATERIALS FOR THOSE LISTED CN THE IRRIGATION DRAWINGS AND SPECIFICATIOI\S, HE ,IAY DO SO BY PROVIDING THE FJLLOW!NG INFORMATION TO THE LANDSCAPE A~CHI TECT =op APPROVAL AFTER IRRIGATION CONTRACTOR'S CONTRACT AWA?D: 1. A STATEMENf l~OICATING THE REASCN FOR THE SUBSTITUTION, JSE A SEPARATE SHEET OF PAPER FOR EACH IT~I/ TO BE SUBSTITUTED 2 CATALOG, PERFOm,ArKE CHARTS, AND FLOWCHARTS ,op EACH ITEM TO BE SUBSTITUTE[) 3 THE COST SAVINGS IF ~HE SUBSTITUTED ITEM IS APPROVED. THE LANDSCAPE ARCHITECT SHALL ~AVE THE SOLE RESPONSIBILITY IN ACCEPTING OR REJECTING ANY SUBSTITUTED ITEM AS AN APPROVED EQUAL TD THOSE EQUIPMENT ANO MATERIALS LISTED ON THE IRRIGATION DRAWINGS AND SPECIFICATICNS EXISTING UT:L.l.TIES AND CCNDITlONS FR I OR TO CUTT I NG INTO THE SO I l_, T~E CO'HRACTOR S~A-L LOCATE Ale. CABLES, CONDUITS. SEWER, SEPTIC TAN,<S ANO OT7ER UTILITIES A,$ ARE COMMONLY ENCCUNTERED UNDERGROUND, ANC HE SHA_L TAKE PROPER PRECAUTIONS NOT ro DAMAGE OR DISTLR3 SJCH IM~ROVEMENTS :FA CONFLICT EXISTS BETWEEN SUCH OBSTAC_ES AND T~E PROPOSED WOP~. THE CONTRACTOR S~ALL PROYFT_Y NOT!Ft THE LANDSCA~E ARCHITECT WHO WILL ARRANGE ~OR RELOCATIJ~S. fHE CO~TRACTOR WIL_ PROCEED IN -HE SAME MANNER I~ ROCK LAYER CR ANT OTHE~ CONDITIONS ARE ENCOJNT~RE). (:B_$1;RVAT!ON ( CITY. 11'.s_fO_l;::JoR MUST APPROVE ALSO) THE CONTRACTOR SHALL AT ALL TIMES PERMIT THE LANDSCAPE ARCHITECT CR HIS AUTHORIZED AGENTS TO VISIT AND OBSERVE THE WORK OR ANY PART THEREO~. HE SHALL MAINTAIN PROPER FACILITIES AND PROVIDE SAFE ACCESS FOR SUCH OBSERVATIONS TO ALL PARTS OF THE WORK. WHERE THE SPECIFICATIONS REQUIRE WORK TO BE TESTED BY THE CONTRACTOR, IT SHALL NOT BE COVERED UP UNTIL TESTED OR APPROVED BY THE LANDSCAPE ARCHITECT AND GOVERNING AGENCIES. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FO~ NOTIFYING THE LANDSCAPE A~CHITECT ANO REQUIRED AGENCY ( 48 HOURS NOTICE RE'.)U!RED), WHERE: ANO WHC:N SUCH WORK IS IN READINESS FOR TESTING. SHOULJ ANY SUCH WORK BE COVERED WITHOUT SUCH TEST OR APPROVAL, IT SHALL, IF SO O~DE~ED BE UNCOVERED A-THE CONTRACTOR'S EXPENSE OBSERVATION Wl_L 3E REQUIRED FOR THE FOLLOWING PARTS OF THE WORK: 1. SLEEVE MATERAL, LOCATIONS. DEPTH OF COVER MUST EE APPROVED BY CITY INSPECTOR PRIOR TO BACKFILL PLACEMENT. 2. lPON INSTAL_ATION AND TESTING OF MAIN L:NES ANC LATERAL LINES: WHE~ ~IPES ARE LAID ANO ARE TO BE SUB~! .TED TO PRESSURE TESTS. DO ~OT COVFR A~Y ~INES UNTIL THEY HAVE BEEN OBSERVED 3. LPON JrJSTAL_ATION AND T~STIN(~ OF VALVES, OU!CK COUPLERS, BACKF _ow PREVEN-Ec? DEV I CE, AU TOMA Tj C CONTROL LEPS, ANC CONTROL V,~LVES AND WIRES 4 WHEN THE SPR:NKLEP SYSTEM IS COMPLETEC, fHE CONTRACTOR, IN THE PRESENCE OF THE LANDSCAPE ARCH:TECT. SHALL PERFORM A COVERAGE -Es-TO DETERMINE :F fHE CDVE~AGE OF WA-ER IS COMPLETE AND ADEQUATE THE C □N-RACTOR SHA~L FURNISH ALL MATERIALS AND PERFORM ALL WORK REOUIREO -□ CORREC-ANY :NADEOUACIES TO COVEP 4. FINAL OBSERVATION AND PERFORMANCE TEST SHALL BE AT -~E SAME TIME AS THE FINAL :NSPEC-ION OF THE LANDSCAPE WORK, IRRIGATION GUARANTEE THE CONTRACTOR. S GUARANTEE SHALL CCNS!ST 0° T~E FOLLOWING: THE ENTIRE IRRIGATION SYSTEM SHALL BE GUA~ANTEED AGAINST DEFECTS !N MATERIAL'S Ar!D WORKMAI\SHIP FOR A F'ERIOD OF 0\JE '. 1) YEAR "R0\1 THE CA-E OF ACCEPTANCE OF WORK, S~OULD TH~ CJNTRACTOR FAIL DURl~G THE GUARANTEE PERIOD TO EXPEDITIOUS_Y CORRECT A DE,ECT UPON WRIT-EN NOTIFICA-ION BY THE OWNER, THE OWNER SHALL CALSE THE WORK TO BE CORRECTEC AND BILL THE ACTUAL COSTS INCURRED TO T~E CONTRACTOR DEFECT CORRECTIONS SHALL INCLJCE THE COMPLETE RESTCRAT!O~ OF EXISTING IMPROVEMENTS THAT WERE DAMAGED AS A RESULT CF THE DEFFCT. PART 2 -PRODUCTS ALL MA-ERIALS SUPPLIED FOR THIS PRO~ECT SHALL BE NEW AND =REE ~ROM ANY DEFECTS ALL DEFECTIVE MATERIAL S~ALL 3E REPLAC~C IMMEDIATELY RINGTITE PVC ( NA) R!NGTI-E PIPE AS SPEC:FIED SHALL BE PVC CLASS 160 OR CLASS 200 WITH R:r,c,-ITE ,JOINTS, .J.M. RINGT!TE PIPE, ~ACIFJ:· WESTERN CR APPRCVEC ECUAL. PLASTIC P:FE FOR USE WITH RUBBER PING GASKETS SHALL BE Rl8ID UNPLAs-ic:zE □ POLYV[~l'l. CHLORID,: i"V( I IZO '.TY"E 1. GRADE 1), MANUFACTURED IN ACCCRDANCE WITH ASTM D 224'.. PLASTIC PIPE MARKED WI fH PRODUCT STANDARD PS 22-70 CONFORMS TO ASTM REQUIREMENTS PIPE SHALL BE SUPPL!EO WiTH PLAIN ENDS OR WIT7 AN INTEGRAL THICKENED EXPANDED GELL WITH RUBBER RING GRCOVE. COUPLINGS FOR PLAN END PIPE SHALL BE OF THE SINGLE RUBBER RING TYPE WITH SOLVENT WELD SOCKE-ON ONE END OR SHALL BE OF THE DOUBLE RING TYPE:. RUBBER RING GASKETS SHALL BE OF A SYNTHETIC RUBBER SUPPLIED IN ACCORDANCE WITH THE R[OU:REME~-5 OF ASTM D 1869 PIPE SHALL BE FURNISHED !N -HE FOLLOWING STANDARD DIMENSION RAT:os (SDR) AND PRESSURE ~ATINGS: 160 PSI ( 1 l \IPA) SOR 26 200 ;:>SJ ( I 4 MPA.) SDR 21 CONCRETE THRUST BLOCKS SHA_L 3E PROVICED AS REQUIRED FOR PROPER ANCHORAGE AND □URABILITY o= T~E R:NGTITE PIPE ALL FOUR (4) INCHES ANO LARGER PVC PLASTIC PRESSURE LINES SHALL BE RINGTITE PVC PIPE POLYVINYL CHLOR[DE PIPE --····-··-·-· _., ... , ........ ,, .. PL.8.STJ.C_J"RE_S_Sl)_R.E,__l._;_!,_E,_;,;_ ALL 1-1 /2" AND SMALLER SHALL BE SCH 40 PVC, ALL 2" AND LARGER SHALL BE . TYPE 1, GRADE 2 ( IMPACT MODIFIED). DESIGNA-ED AS FVC 1220, CLASS 315 (SOR 13. 5), CONFORMING TO COMMERCIAL STANDARDS CS256-63. E'LLSIK_.!JQN-PR_E_5SURE L [ NES FOR PIP I NG OOW~STREAM OF REMOTE CONTROL \/ALVES TYPE I. GRADE 2 ( IMPACT MOJIFIED), AS DESIGNATED AS PVC 1220, CLASS 200 ( SDR21), COt\FORMING TO COMMERCIAL STANCARCS CS256-63 IDENTIFICATION FURNISH PLASTIC PIPE CCNTINUOUSLY AND PER\1ANcNTLY MARKED WITH FOLLOWING :NFORMATION MANUFAC-URER' S tJAMC: OP TRADEMARK, SIZE, CLASS ANO TYPE OF PIPE, WORKING PRESSURE AT 73. 4 DEGREES F, AND NA-IONAL SANITATION FOUNDATION (NSF) RAT HlG SLEEVES SLEEVES SHALL BE SCH, 40 PVC (SCH 80 UNDER VEHICULAR PAVING) 2 TIMES THE PIPE SIZE DIAMETER AND EXTEND 12· BEYOND EACH SIDE OF PAVEMENT THE LETTERS "E" FOR ELECTRICAL OR 'w" FOP WATER SHALL BE STAMPED OR CHISELEJ ON THE PAVEMENT D'.RECTLv ABOVE THE SLEEVE PVC FITTINGS PVC SCHEDULE 40 SHALL NOT BE THREADED. ALL THREADEJ PVC PIPE SHA~L BE SCHEDULE 80. FITT:NGS SHALL BE PVC SCHEDULE 40 OR 80, AS REOU!RED. SCH,□U E 40 FITTINGS SHALL BE USED FOR INSTALLATION ON THE DISCHAPGE SIDE OF ~EMOTE CONTROL VALVES AND SCHEDULE 80 FITTINGS $HALL 3E USED FDR CONTINUOUSLY PRESSURIZEC PIPE ON THE SLlPPLY SJDC-oc:-REMOTE CONTROL VALVES --.. , ... . . . ... ----···· FITTINGS AND COUPLINGS FOR PLASTIC PIPE S~ALL BE THREAOEC OR SLIP-FITTED TAPEREJ SOCKET SOLVENT WELD TYPE. THREADED ADAPTERS SHALL BE PROVIDED W'TH SOCKET P'PE FOR COhNECTIONS TO THREACED P:PE. PLASTIC PIPE FITTING AND COUPLINGS SHALL BE PVC I OR PVC I/I I MATERIAL SLPPLIED IN T~E SAME SCHEDULE SIZE SPECIFIED ,QR THE PIPE. THE TYPE OF PLAST:C MATERIAL AND SCHEDULE SIZE SHALL BE INDICATED ON EACH F:TTII\G CR COUPLI~G. FITTINGS AND COUPLINGS SHALL COMPLY WI TH THE FOLLCW: M; SPECIF I CA Tl ONS. ~S~G~C~K=E~T~F~l_T~T~l~N=G=S ____ _ SCHECULE 40 ASTM D2466 SCHEDULE 80 ASTM 02467 ;HREA □ED FITTINGS SCHECULE 80 ASTM D2464 BRASS PIPE AND FITTINGS BRASS PIPE SHALL BE RED BRASS SCREWED PIPE CONFORMING TO FEDERAL SPECIFICATICN NO WW-P-35'. FITTINGS SHALL BE RED BRASS CONFOR\1ING TO FEDERAL SPECIFICATION NO WW-P-46C, GALVANIZED STEEL PIPE AND FITTINGS (N/A) GALVANIZED FIPE SHALL BE STANDARD WEIGHT (SCHEDULE 40) COMPLYING WITH THE RECUIREMENTS OF ASTM A 120. STEEL PIPE SHALL BE JOINTEJ WITH GA,_VANIZED THREADED, STANDAR'.l WEIGHT MALLE.~BLE IRON FITTINGS ANC COUPLINGS. COPPER PIPE COPPER PIPE SHALL BE fYPE K IN ACCORDANCE WITH ASTM B 88 COPPER PIPE SHALL BE JOINT~□ WITH THE APPROPRIATE SOLJER TYPE WROJGHT COPPER FITTINGS FOR 2-1/2 INCH AND SMALL~R SIZ~S CAST BRASS FITTINGS S~ALL BE USED FOR SIZES OVER 2-1/2 INCHES. AUTOMATIC CONTROLLER AUT0\1ATIC CONTROLLER S7ALL BE OF THE TYPE AND PER THE MANU~ACTURER SHOWN ON ~LAN OR APPROVED EOUAL. iT SHALL BE FULLY AUT0\1A TIC, WI TH PROVIS I CNS FOR MANUAL OPERATION, SI ZED TO ACC0\1MODATE THE NUMBER CF STATIONS OR CONTROL VALVES INCLUDED IN THE SYSTEM OUTDOOR MOCE_S SHALL BE HOUSE □ IN A VANDAL-PROOF AND WEATHERPROOF ENCLOSURE WITH LOCKING COVER LOW VOLTAGE CONTROL WIRE ALL WIRING TO BE USED FCR CONNECTING THE AUTOMATIC CONTROLLER TO THE ELECTRIC SOLENOID ACTJATED REMOTE CONTROL VALVE SHALL BE TYPE UF-600V, SOLID COPPER, PVC INSULATION, SINGLE CONDUCTOR, UflDERGROUND, UL -·APPROVE[: LOW VOLTAGE CONTROL CONDUCTORS SHALL BE SUPPLIED IN THE SIZES $~OWN ON THE ~LAN OR IN ACCORDANCE WITH THE CONTROL EQUIPMENT MANUFACTURER'S RECOMMENDATION. AND $~ALL BE UL-APPROVED FOR □!REC-BURIAL :NSTALLAT!ON, 110 VOLT WIRE TO CONTROLLER 110 VOLT WIRE SHALL BE 0 ER LOCAL CODE AS TO TYFE AND DUALITY. CONDU:T CONDU[T SHALL BE PVC ELECTRICAL CONDllT VALVE B•)XES ALL REMOTE CONTROL VALVES AND GATE VALVES SHALL BE INSTALLED IN SUITABLE VALVE BOXES AS SHOWN !~ DE7A!LS. ALL REMOTE CONTROL VALVE BOXES SHALL BE PLASTIC ( BY AME:EK. OR APPRJVED EOUAL ) , 8LAC~ OR CR(E'J WI-H GRC:EN COVER ( PJRPLE COVER FOR RECLAIMED WATER SYSTEMS) THE CONTRACTOR SHALL PAINT THE IDENTIFICATION NUMBER o= THE VALVE AND ~HE CONTROLLER CLOCK ON THE COVER OF THE VA~VE BOX. TH~ PA:NT S~ALL BE ALUMINUM ASPHALTIC-BASE WATE'lPROOF PAINT GATE V.',LVES CATE VALVES 3·· AND SMALLER SHALL BE 125 LBS SWP BRONZE GA-E VALVE WITH SCREW-IN BONNET, NON-RISINC STEM AND SOLID WEDG':: DISC ANC THREADEC ENDS, GATE VALVES SHALL BE SIMILAR TO THOSE MANUFACTURE □ BY NIBCO, HAMMOND CR APPROVED EQUAL AND SHALL BE INSTALLED PER INSTALLATION DETAIL. GATE VALVES SHALL BE SIMILAR TO THOSE MANUFACTURED BY NIBCO, HAMMOND OR APPROVED EQUAL AND SHALL BE INSTALLED PER INSTA~LAT:ON OU!CK-COUPLING VALVES AND ASSEMBLIES OU!Ck-COUPLING VALVES SHALL BE BRASS OR BPONZE WITH BUILT-IN FLOW CO~TROL Ar,□ SEc.F-CLOSING VALVE MJ[) SUPPLIED IN C>NE ( 1") HKH SIZE UN_ESS OTHERWISE PEOUIRED W7EN A QUICK-COUPLE~ ASSEMBLY IS SPECIFIED, IT S~ALL CONS:ST Q, THE OU!Ck-COUPLER KEY AND HOSE EL_ TH~ COUPLER KEYS AND HOSE ELLS SHALL BE □= TH[ SAME MANUFACTURER AS THE COUP_ING VALVE. REMCTE CONTROL VALVES REMCTE CONTROL VALVES SHAL~ BE E_ECTR!CALLY OFE?ATED. THEY SHALL BE EOUIPPED WITH FLOW CONTROL ADJUSTMENT ANO CA 8 ABIL!TY FOR MANLAL OPERATION THEY SHALL BE MADE SO THAT T~EY MAY BE READILY DISASSEMBLED FOR SERVICING BACKFLOW PREVENTER E!ACKFLOW PREVE'"TER, WHERE REQUIRED, SHALL BE CF SIZE AND -ypE AS INDICATED ON DRAWINGS ALL BACKFLOW PREVENTION UNITS SHALL BE INSTAL~ED iN ACCORDANCE W[TH THE REQUIREMENTS SET FORTH BY LOCAL COJES AND T~E COUNTY DEPARTMENT OF ENV!RONMENTA_ HEALTH SERVICES. SPRINKLER HEADS SPRINKLE? HEADS. 3UBBLE? HEADS AND SPRAY ~OZZLES SHALL BE OF THE TYPES ANJ SIZES SHOWN ON THE QLANS. THEY SHALL BE CONSTRUCTED OF BRONZE, 3RASS, STAINLESS STEEL AND/OR H!G~-!MPACT PLASTIC. ALL HEADS OF A PARTICULAR TYPE OF FJNCTION IN THE 5vsTEM SHALL BE OF THE SAME MANUFACTURE AND SHALL BE MARKED WITH T7E MANUFACT~RERS' S NAME AND IDENTIFICAT:ON IN SUCH A 0□SI-ION THAT THEY CAN BE :□ENTIFIED WITHOUT BEING REMOVED FROM THE SYSTEM LOCATOR TAPE (ALL PRESSURE MAINS AN) DIRECT BURIAL WIRES) ALL PRESSURE PIPE SHALL HAVE A CONTINUOUS BLUE-COLOREJ TRENCH MARKER METALLIC TAPE (PURPLE FOR RECLAIMED WATER) ~LACE □ SIX INCHES (6'') BELOW F:NISHED GPADE ( :2· ABOVE PIPE FOR RECLAl~ED) DIRECTLY ABOVE THE BURIED PIPE \FOR RECLAIMED INSTALL A SECOND MARKE~ TAPE CONTINUOUSLY ON TOP OF P'PE SECURED WITH ~LASTIC TAPE FASTE~ERS BANDED AROUND THE PIPE AT NO MORE THAN~· APART) ALL DIRECT BURIAL WIRES SHALL BE MARKEJ WI-HA CO~TINUOUS RED-COLORED TRENCH MARKER PLAS7IC TAPE PLACED SIX INCHES 16'') BELOW FINISHED GRADE DIRECTLY ABOVE THE BURIED WlRES. MARKER TAPE SHALL BE "ALLEN MARKING -A 0 E,. OR "ALA2MATAPE" AS MANUFACTURED BY PAUL POTTER WARNir,c -APE, :1,c , OR AP~ROVED EQUAL TAPE SHALL BE THREE INCHES ( 3··) WIDE. CHECK VALVES CHECK VALVES SHALL BE OF PVC, BRASS OR BRONZE. VERTICAL SPRING LOADEJ AND SWING CHECK. SAND ENC.A SEMEN T SAND ENCASEMENT FOR ALL lRRICA'lmJ PIPE, DIRECT WIRE AND ELECTR:CAL CONDUIT SHALL BE PLASTER OR A M!~IMUM SAND ECu:vALENCY OF SC. BOOSTER PUMP STATIOf\ ( IF REOlclRED) BI.RI AL C<lNTROL MORTAR SANC WITH THE CONTRACTOR SHALL CONSTRUCT BOOSTER PUMP S"AT ION, ON CO~CRETE PAD WITH PANEL$, WEATHERPROOF HOUSING. BY-PASS VALVE. ;:>RESSURE GAUGES, SWITCHES, DELAY-ST.~RT RELAYS, STARTERS, HIGH VOLTAGE WIRING, Mm RELATED EOUIPMUH AS REQUIRED THE CONTR~CTOR SHALL MAKE FINAL HOOKUP AFTER ASSEMBLY :s CCMPLETED PROVID~ S~CP DRAWING PRIOR TO INSTALLATION FOR APPROVAL MISCELLANEOUS ALL OTHER MATERIALS NOT SPECIFICALLY DESCRIBED BUT REQJIR~O FOR A CCMPLETE AND PROPER IRRIGATION SYSTEM INSTALLATION, SHALL BE NEW, FIRST-OU~LITY OF THEIR RESPECTIVE l<INCS, A'JC SLFI.JECT T:) T'-IE APPROVAL OF T~E LANDSCAPE A~CHITECT PART 3 -EXECLTION l'JSPECTION PRIOR TO ALL WORK OF T~IS SECTION, THE CCNTRACTOR SHALL CAREFULLY J~SPECT THE SITE TO VE~IFY THAT wo~K MAY BEGIN T~E CONTRACTOR SHALL CHECK THE INSTALLED WORK CF ALL OT~E~ TRADES A~D VERITY THAT ALL SJCH WO~K IS CCMPLETE TO -~E POl~T WHERE THIS INSTALLATION MAY PROPERLY COMMENCE. ALL WORK ON T~E IRRIGATION SYSTEM, INCLUC!'JG HYDROSTATIC AND CCVERAGE TESTS, PRELIMINARY OPERA-IDNAL TESTS CF THE AJTO~ATJC CCNTROL SYSTEI/. AND IHE BACKFILL A~D CENSI~ICAT!ON OF TFE~CHES A~D OTHER EXCAVATIONS SHALL BE PERFORI/ED BEFORE SOIL CO~DITIONING Ar,D LEACHING AND BEFORE PLANTING ( EXCEPT FCR URiP IRRIGAl ION TUB I NG FOR MULTI -OUTLET EMITTERS, WHICH SHALL BE I NS TALLED AT THE SAME TIME OR IMMEDIATELY AFTER PLANTING l. LARGE SPECIMEN PLANTS MAY BE PLANTED BEFORE INSTALLING THE IRR\GATION SYSTEM. THE CONTRACTOR SHALL VERIFY THAT THE IRRIGATION SYSTEM MAY BE INSTALLED II\ STRICT ACCORDANCE WITH PERTINENT CODES AND REGULATIONS, THE ORIGIN~L DESIGI\ THE REFERENCED STAr,DARDS, A~D THE MANUFACTURER'S RECOMMENDAT:CNS. THE CONTRACTJR SHALL CAREFU_LY CHECK ALL GRADES TO SATISFY ~:MSEL~ THAT HE MAY SAFELv ~ROCEED BEFORE STARTING WORK ON THE SPRI~k_ER !RR:GA-ION SYSTEM THE CO~TRACTOR SHALL CHECK ~XISTING UTILITIES DRAWINGS FOR EXISTING UTI_:TY LOCATIONS. EXERCISE EXTREME CARE IN EXCAVATING AND WORKING ~EAR EXISTING UT!LIT!ES THE CONTRACTOR SHALL BE RESPONSIBLE =oR DAMAGES TO u-lLITIES WHICH ARE CAUSED B· HIS OPERATIONS OR NEGLECT ALL SCALED DJME~SIONS ARE A~PROX!MATE THE CONTRACTOR SHALL CHECK AND VERIFY A~L SIZE DIMENSIONS AN' RECEIVE LANDSCAPE ARC7!TECT' S APPROVAL PRIOR TO PROCEEJING WITH WORK UNDER THIS SECTION. JISCREPANC:IES IN THE ~VENT OF A DISCREPANCY, THE CONTRACTOR SHALL IMMEDIATELY ~OT!FY THE OWNER 0~ LANDSCA 0 E ARCHIT~CT. JO NCT PROCE~D WITH INSTALLATION IN AREAS OF JISCREPANCY UNTIL ALL SUCH DISCREPANCIES HAVE BEEN FULLY RESOLVED. ~HYS[CAL LAYOUT AND OBSERVATION .. .. ···------- 0 R!OR TO lNSTAL_AT!ON. THE CONTRACTOR SHALL STAKE OUT ALL ~RESSURE SUP 0 LY LINES. ROUTING AND LOCATION 0~ TURF POP-UP SPRl~K_EP HEADS ALL LAYOUT SHAL~ BE APPROVE) BY THE LANDSCAPE ARCHITECT PRIOR TO INSTALLA-ION UNLESS OTHERWISE DIRECTED. OUAL"FICATIONS OF INSTALLERS PROV:□E AT LEAST ONE PERSON WHO SHALL BE PRESENT AT ALL TIMES DURING EXECUTION OF THIS PORTION OF THE WORK AND w~o SHALL BE THOROUGHLY FAMILIAR WITH THE TYPE OF MATERIALS BEING INSTALLED AND -HE MANUFACTURER'S RECOMMENDED METHODS OF INSTALLAT'ON AND WHO SHALL DIRECT ALL WORK PERFORMED UNDER THIS SECT!O~ MANUFACTURERS' S DIRECTIONS MANUFACTURERS DIRECTIONS AND JETAILEO DRAW:NGS SHALL BE FOLLOWED IN ALL CASES WHERE THE MANUFACTURERS OF ARTICLES USED IN THIS CONTRACT FURNISH DIRECTIONS COVERING POINTS NOT SHOWN IN THE DRAWINGS AND SPECIFICATIONS. PERMISSION FOR WATER SHUTOFF PERMISSION TO SHUTOFF ANY EXIST'NG !N-LSE WATER LINE MUST BE OBTAINED 48 HOURS IN ADV.ANCE, IN WRITING FROM -HE OWNER THE CONTRACTOR SHALL RECEIVE INSTRJCTIONS FROM -HE OWNER AS TO THE EXACT LENGTH OF TIME OF EACH S~UTOFF WATER SUPPLY--PDINT OF CONNECTION THE IRRIGATION 3YSTEM SHALL BE CONNECTED TO WATER SUPPL• POINTS OF CONNECTION AS INDICATED ON THE DRAWINGS CONNECTIONS SHALL BE MADE AT A~PROX!MATE LOCAT:ONS AS SHCWN ON DRAWl~GS. CONTRACTOR :~ RESPONSIBLE FCR MINOR CHANGES CAUSED BY ACTUAL SITE CONDIT!O~S. ELECTRICAL SUPPLY ELECTRICAL CONNECTIO~S FOR THE AUTOMATIC CONTROLLER(S) SHALL BE MADE 10 ELECTRICAL DCINTS OF CONNECTIOI\ AC. [ND,C.ATED ON THE DRAWINGS. CONNECT:CN5 SHALL B~ MADE AT APPROXIMATE LOCATIONS AS SHOWN ON DRAWINGS CONTRACTOR IS RESPONSIBLE FOR MINOR CHANGES CAUSED BY ACTUAL SITE CONDITIONS. TRENCHING ------ EXCAVATION SHALL BE OPEN VERTICAL CONSTRUCTION SUFFICIENTLY WIDE TO PROVIDE FREE WCR<ING SPACE AROUND THE WORK INSTALLED ANJ TO PROVIDE AMPLE SPACE FOR BACKFILLING AND COMPACTING T'IENCHES FOR PIPE S-IALI_ BE CUT TO REQUIRED GR.~DE LINES, ANJ T~ENCH BOTTOM SHALL BE COMPACTED TO PROVIDE AN ACCURATE GRACE AND IJ'JIFORM BEARING FOR THE ruLL LENGTH OF THE LINE W-IEN TWO OR MORE PIPELINES ARE INSTALLED IN THE SAME TRENC7, THEY S~ALL BE SEPARATED 3Y A MIN!MLM HORIZONTAL CLEAR DISTANCE OF 2 INCHES AND THEY S~ALL BE l~STALL~O SO THAT EACH PIPELINE. VALV~. 0~ OTHER PIPELINE COMPONENT MAY BE SERVICED OR REPLACED WIT~OJT DISTURBING THE OTHER. DEPTH OF TRENCHES S~ALL BE SUFFICIENT ro PROVIDE A MINIMUM COVER ABOVE THE TOP OF THE PIPE, AS FOLLOWS: I. 12 l~ICf.'ES 18 INCHES 3. 24 INCHfS 4, 12 INCHES PAV ltK. 5. 18 HKHE'o 6 JO INCHES 7. 36 INCHF:S ROADS OVER OVER OVER OVER OVER 01/ER OVcR NON-PRESSURE LATERAL LINES. PRESSURE MAIN LINES LESS THAN J'' DIAMETER PRESSURE MAIN LINES J'' -5-1/2'' DIAMETER. S_EEVES FOR LATERAL LINES UNDER PEDESTRIAN SLEEVES CROSSiNG UNDER PEDESTRIAN PAV!NG. SLEEVES CROSSING UNDER VEHICULAR PAVING SLEEVES 6'' OR LESS :~ DIAMETER CROSSING UNDER TRENCHING THROUGH ~REAS WERE TOPSOIL HAS BEEN SPREAD· DEPOSIT TOPSOIL ON ONE SIDE CF TRENCH AN □ SUBSOIL ON OPPOSITE SICE. 8H-;C, N~•t:1(1 R,J ',I~ 0/-IYi ·:,cw r·,,"q1 •·1, ·:1;:·1 ;,~ !.:,1,;>/59:',-J':'.!? ("(!. I ;c ,i IA~'.• ENGl~EER'S SIGNATURE REOUIRED ON PAGE 1 ONLY APP'!OV£0: ,~-------ENGINEERING PLAN CHECKER DATE APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS "AS BUILT" --············-·· ~AME DATE TlTLE: ___ ..... ' . REVIEWED BY: '~SPECTOR DATE ---+------------------ □ETA IL. 'ii \},I\DSCA;>~ " # •u~~ ---------------- -.-_·_--_,_-_---=._---::_--:,_'=--=--=--:::: SH2EET 11 CITY OF CARLSBAD I 'I SH1EYS _ PLAr,.ll'ltlflJG DEPART~E~T . . -·~==========="--=== ..... ---+---t-----t TAYLOR MADE GOLF " . ···-··-·--·-+-----1 GATE VALVES MAY BE FURNISHED WITH EITHER OPERATING NJTS OR $ ~\.· . ,:: ">fr- HANDWHEELS AND SHALL BE l NST ALLC:D BELOW GRADE IN A G~EEN VALVE {£ ~, ' --··· -+-------------------t ........ . BOX WI TH LOCK I NG COVER (STENCIL "GV" ON LINDERS I DE OF COVER). \I ,. n+",,__•'--+---• ----------------+------4----· -· ..... . ----------- GLOBE VALVES -S TR A IGl·H VALVES -BALL VA -VE S ~ r ~ ,7~,; °':~ !~'••1--·_-_-_-_-_-t._-_-_-_-_-_-_t-t-·-···-_ -=-=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=--=-:-=--=--=--=--=-::-::_-::_-::_-::_-::_::-=-~------·-+······ ---··· GLOBE VALVES STRAIGHT VALVES AND BALL VALVES SHALL BE OF SIZE ~OFCl\l.l~~,4",.t-----t---i-----------------+------+-------<>----+----, AND TYPE AS INDICATED ON THE PLANS DATE INITIAL ENGINEER OF' WORK REVISION DESCRIPTION DATE INITJA_ DATE INITIAL CTHER APPROVAL CITY APPROVAL . APPROVED: CARLSBAD RESEARCH CENTER CARLSBAD, CALIFORNIA ·-""'"""' . '. " . ' " " . . - {(-b-'17 -----~------------ ASSiSlANI PLANNING Dl~E;.CTOR DATE: ; DWN BY: ____ PROJECT NO. DRAWING NO. j 'CHKD BY·____ HDP96-14 352-3c. I ,i-'-R--, v __ w.::_D__:B:_r--·, ==cc .. c:c ..... c:: .. _. ~---------______ I C.M, W, D, JOB NO, _9_6_-_2_4_4 ______ _ BACKr 11 I I NG BACKFILL MATERJA_ SHALL BF APPROVFC SOIL. INCLUDING Cl_CCS AND ROCKS OVER 2-1/2 INCH REMOVED FROM THE ~~~MIS[S AND CISPCSED OF OWNER. UNSUITABLE MA -ER I AL, IN SJZE, S 1/,LL BE LEGALi Y Al NO COST TO PIPE SHALL GE BE'.lDE) IN AT I EAST 2 11\CHt_s OF FINELY DIV:DED MATERIAi_ TO Pi<OVID[ A FIRM, UNIFCRI~ BEARING. AFTER LAv:NG, THt. Plr'E SHAU tlf SURROU'<OED W!TII ADCITIONAL FINELY o:v,DED MA-ERIAL -o AT LEAST 2 INCH~S OVrR !Hr TCP OF THE PIPE. TR[NCH BACKFILL, SUfFICIENT TO ANCHOR THE PIPE, ~AY BE DEPOSITfD 8rFORE iHE PlPtl !Ne. Pflc_ss:.fl[ T[STING, EXCEFT THAT JOINTS SHAL.l_ RF.MAIN EXPOSED UNfL SAIISfACTORY COl,IFLETION OF TESTING. Al __ !_ BACK, I l __ I \J~ SHALL BE CONE CARU-ULL Y AND SHALL. 8f: Mr CHAN I CAL.I Y COMPACTFIJ 10 A JRY DENSITY ECUAL TO ADJAC[NT UNDIS-URBED SOIL IN PLANTING AR~AS. BACKFILL WILL CONFORM 10 A □JACfN-GRADES WJTIJOUT DI PS, SUNK[\J A"<~AS, HUMPS OR OH-ER SURFACE I RRtGUI AR:·· 1 r S. H.OODING Or l~c\JCHFS Wll_l_ BE PERMITTED ONLY WITII APPROVAL OF THE LANDSCAPE A"<C~ITECT. SURl''LU5 SOL ~c,~AINING AFTER GACKFILLING SHAL.L BE DISPOSFD OF ON THE PREMISES AS DIRECTED BY THf: 1. ANDSCAP[ ARCIL TCT. INSTALLATION OF POLYVINYL CHLORIDE PIPE EXE RC I Sc CAR~ .IN HANDLING, LOAD I NG, UNLOAD I NG, AND STORING PLASTIC ~1~E AND FITTINGS ~NIJtR COVER UNTIL READv TO INSTALL: TRANSPORT ~LAST IC PIPE ONLY ON A VEHICIE WI IHA tlfll I ONG ENOUGH TO ALLOW TIE PIPE TO LAY FLAT TO AVOID UNDUE BENDING AND CONCENT~AlcD FXIERNAL LCAD. CAREFULLY INSPECT ALL FIPE ANC FITTINGS BEFORE INSTALi.AT iON, R~MOVING A, I_ DIRT, SCALE, AND BURRS ANO REAM:NG AS REQUIRED; INSTALL ALL PIPE WITH ALL MARKINGS U? FOR VlSUAI INSPECTION ANO V~C,J:CJCATION RE~AIR ALL DENTED AND CAI/AGED PIPE BY cu--_NG OUT THE DENTED OR DA~ASED SECTION AND REJOINING WITH A COUPL:NC. A __ ~vc PIPE SHALL LAY FREE IN THE [RENCH w:·H NO INDUCED ST~A]N A\JJ WITH SUFFICIENT ALLOWANCE FOR EXPANSION AND CONTRACTION AS R~C □MMENDED BY THE MANUFACTURER. RDJTI~G IS DIAGRAMMATIC AND SHALL BE INSTALLED IN SUCH A MA'1'1~R AS TO CONFORM WITH DETAILS PER PLANS. SO_Vc\JT SHALL BE APPLIED TO PIPE ENDS IN SUCH A MANNER THAT ~o MAT~~IAL IS DEPCSITED ON THE INTERIOR SURFACE OF THE PIPE 0~ EXT"<JJED INTO THE INTERICR OF rHE P:PE DURING JOINTING. EXCESS C~ME\JT ON THE EXTERIOR OF THE JOINT SHA! I_ fl[ WlPED CLEAN IMMEDIATELY AFTER ASSEMBLY. IN JOINING, USE ONl.v THC: MANUFACTURE.~' S SPECIFIED SOLVEI\T AND MA'~E ALL :□INTS IN STRICT ACCORDANCr W'-H fHE MANUFACTURER'S RECOMMENDED METl·OCS; GIVE SOLVENT WELDS AT LEAST 15 MINUTES SETJP l!ME BEFORE MOVING ANC HANDLING AND 24 HOURS CURING TIME BE=□:,,~ =JLLING WITH WATER 'HREADE □ PIPE JCINTS SHALL BE MADE us:NG TEFLON TAPE OR OTHE"< APPROVED ~CINT!~G ~ATERIAL ( INCLU□:NG .. HRf-ADFI) "MARL[X" ~:c·1~GS). SOLVE~T SHALL NOT BE USED W'.TH THREADED JOI\JTS. ~:~E SHALL BE PRCTECTlD FROM TOOL DAMAGE DURING ASSEMBLY. VIS~S SHALL HAVE PLEATED JAWS. STRAP WRENCHES SHAI.L BE USED FO"< INSTALLATION OF F]TT'.NGS AND Nl~~-~s =DR PLASTIC-TC-STEEL CONNECTIONS, WORK THE STEEL CONNECTIO~S 0 :RS", USE A ~ON-HARDENING NON-LEAD BASE PIPE DOPE ON A __ 'HREADED PLASTIC TO STEEL CONNEC-:ONS AND USE ONLY LICHT W~ENCH ~RESSURE. ALL PLASTIC-IQ-STEEL CONNECTIONS SHALL BE MAJ~ WITH ~L•S•'.C M,>LE ACAPTORS. PROVIDE EACH ASSEMBLY WITH llS OW\J OUTicT =R □M THE !RRiGATION MAIN. (NO MULTIPLE ASSEMBLIES.) ~vc PIPE INSTALLATICN UNDER Ex:s-:NG PAYEMENI ~!PING ro HE INSrALLED UNDER EX:S7iNG PAVEMENT MAY BE ]~STALLED 3Y c.'ACKING, ECRI~G. CUTTING AND PA-CHING, OR HYDRAULIC J"<IVING ~YDRAULIC CR!VING WILL NOT BE PERMl Ill □ UNllER ASPHAL TIC 20~CRETE ~AVcM[NT. WHERE CUTTING OR BREAKING OF Ex:s:!NG PAVEMENT IS NEC~SSARY, SECURI' PcRMJSSIOI\ FROM TH[ LANDSCAPE ARCHITECT BEFORE CJTTING OR 3REAKING T~E PAVEMENT AND THFN MAKE ALL NECESSARY REPAIRS AND REPLACEMENTS TO THE APPROVAL OF -HE LANDSCAPE ARCHITECT ANJ AT NO ADDI f[ONAL CCST. PIPE INSTALLATION UNDER PROPOSED PAYING TRENCHES l.CCA ffD UNDER ARE:AS WHERE PAV I NG, ASPIIAL TIC CONC"<~TE OR CONCRETE, WILL BE INSTALLt.D SHALL BE llACKf"IU r'D WJT;I SANJ '. A L~YER SIX ( 6) INCHES BELOW THE P:PE AND THREE (3) !°'CHES A30VE THE: PI PE) ANC COMPACTED IN LAYERS -o 95 PERCENT CO,l''ACT I ON, US I NG MANUAL OR ~EC~ANICAL TAMPING DEV:CES. TRFNCHFS FO~ PIPI'1G SHAI L BE COMPACTED TO EQUAL COMPACTION OF THE EXISTING AJJACENT UNDISTURGEC SCIL AND SHALL BE LEF-IN A FIRM UNYJE_)JNC CONDIT ION. Al_L TRENCHES SIIAI I m: I FTT FL_USH WITH THE ADJOINING GRADE. THE IRRIGATION CONTRAC-□R SHALL SET IN PLAC~. CA~ AN □ PRESSURE TEST ALL PIPING UNDER PAV:NG PRIOR TO THE ~AYING WORK. ALL PLASTIC PRESSURE PIPE lJN □ER PAVEMENT SHALL BE INSTALL~) IN A PVC SLEEVE. CONCRfTF THRI.ST BLOCKS .ALL PRESSURE PIPE 4" AND SMALLER, ,'01.YYINYL.. CHI ORI)>. 0'< AS'3FSlOS CEMENT, SHALL I-AVE THE CORRECT S: ZED CONCRETE THRUST BLOCi\ INST AL LED A' [Vt.RY ABRLJP T C0M ~GF Dr" Al.. I GNMENT; AT GA TE VALVES, AT TEES, ELBOWS AI\D CROSSES, AND A-ENllS OF P!Pr RUNS; cl', WHfi,tVER Tl,F FI Fl D EI\G I I\EER DEEMS ONE TO BE NECESSARY. THRJST 3LOCKS ARE TO BE lNSfALLEC AS PfR !Jr TAIi IJRAW-NGS. AUTOMATIC CCNTROLLER LOCATION AND :NSTALLATION THE CONTROLLER LOCATION IS DIAGRAMMArlc ANI) SHA! I_ 3~ s~tCIFICALLY l.OCATFIJ BY THE OWNER OR LANDSCAPE ARCHITECT. MAKE ALL ELECTRICAL CONNFCf'ONS INSIDE CONTROLLER CA3l'JET. CONTROLLER SHALL BE GROUNDED Ar POWr .. R SUPPi y rJy GRD.J~J Wl RE Al_L I OCAI. Af-0 APPL I CABLE CODES SHALL TAKE PRECEDE NCC: ·r '1 THE FURNISHl~G AND/OR CONNEcr:oN OF '?□ VOLT ELECT~]CAL SE~VICES TO THE CONTROLLER. IN MUL ·· 1PL1:'. CONTROL! [R l'JSTALLATIONS, ENCLOSURES SHALL BE SIZED .ACCORDl~GLY. NO 110-VOL.T W:RF. f<UNS SIIALL Pt,SS ~~OM CONTROLLER CABINET TO CABINET. EACH CON-ROLL~R SHAI I liAV~ A SEPARAT[ ELECTRICAL SERYICF 'l'l'¼>fo :>H13 ,._CT l-2D LOW VOLTAGE CONTROL WI"<ING WIRING SHALL OCCJ?Y THF SA.Ml !"Ht NCH AND SHALL 13l. INST AU.ED THE SAME ROUTE AS "'~ESSJ'lE SUPPi Y I I Nf S Whc 1,EVUI POSSIBLE. MORE THAN ONE WI~= IS P_ACED IN A TRENC~. THF WIRING SHALL TAPE:D roGF. THf:R AT ]'H[RVALS OF TEN ( 10) FEET. ALONG WHERE BE AT LEAST 2 FEET □= SLACK (4 FOOi MINIMUM EXPANSION LOOP) SHALL BE LEFT AT EACH SPLICE AND POINT OF CONNECTIC~ IN PULL BOXES AND VAL VE 8CJXFS. CONTROL WIR~S SHA __ BE LAID LOOSELY IN TRENCH WITHOUT STRESS OR ST Rt_ TCH I NG. FIELD SPLIC~S 3ETWc~N THE AUTOMATIC CONIRCI l .. tR AND EL.ECTRICAL CONTROL VALV~S WIL-NOT BE ALLOWED WITHOUT PRIOR APPROVAL OF THE IAN □SCAPE A~CHITECT AI_L CO'-HROL WI RES SH.ALL BE SOLID CCPPER, 600 VOLT, TYPE UF, CONFORMING TO THE DRAWINGS, AND THE FOLLOWING WIRE COLORS AND INSTALLATION REQUIREMENTS: 1. NtUIRAI_ )\'IRES: WHITE (#12 AWG), DO NOT INTERCONNECT \JEJTRAL WIRES 3~TWEEN CONTROLLERS. 2. SPARE WIRES TWO (2) RED (#14 AWG) FROM FURTHEST VALVE OR MA~r~·o1 D. ib tACH CONTROLLER. WIR~ CONNECTIONS N:'JT"<Al, PILOT ANO SPARE WIRES Sl·ALL BE INSTALLED w:-H A 2' -o" COJ_~J EXCESS WIRE LENGTH AT EAC~ lND tNCLOSURE. EACH AND EVERY WIR~ SPLICE SHALL BE SOLDERED TOGETHER (USING 50-40 SOLDER), THEN ENCASED IN THE WATERPROOF EFOXY OF THE "SCOTCH-PAC" OR "PEN-TITE'' CONNE:TORS AS SHOWN ON STANCAR□ DRAWING 1-15, WIRE SPLJCES SHALL dE MAJE ONLY IN VALVE OR FULL BCXES. WIRE BUNDLES EACH INDIVIDUAL CGNTROl.lf:R CLOCK'S CONTROL WIRES SHALL BE BUNDL.ED AND TAPED TOGETHER SEPARATELY FROU OTHER CONTROI.LER' SWIRES WITH COLORED TAPE AT INTERVALS I\OT EXCEEDING 10' -0". CONTROLLER IDENTIFICATION TAP[ COI_ORS SHALL BE AS FOLLOWS (JSE AS MANY AS ~ECESSARY). CONTROLLER "f,," ,, 8" .. c" ,. D" "E" "F" TESTING-WIRING TAPE COLOR BLACK RED WHIT[ Bll.,E GREEN YELLOW ALL WIRING SHALL SE TESTFD FOR CONTINUITY, OPEN CIRCUITS ANO UNINTENTIONAL GROLNCS PRIOR TC CONNECTING TO EQU'.PMENT. THE M]N(MUM INSULATION fit.S!SfA~CE: TO GROUND SilALL BE FIFTY (50) MEGOHMS. ANY WIRING NOT MEETING [HIS RfOUIREMfN-SHALL BE REPL•.CED, .~ T THE co~ TRACTOR' s EXPE:NSE. ALL '//IRES IN PciLL BCXES SHALL BE ~OOSE AND SHAl .. i .. NOT COME WITHIN THREE INCHES (2") FROV ~1 □. BOXES SHALL BE s:zE □ ACCORDINGLY TO ACCOMMO □AIE THJS RECU'R~V[N- V AL VE BOXES INSTALL VALY~ 80XES AS SHOWN ON □[TAIL !~STALL NO MORE THAN CNE VALVE PER ECX. VALVE BOXt5 SHALL BE LOCATEC !~ ACCESSIBLE AREAS WHICH ARE NOT HIGHLY VISIBLE. T~E 10P SU~FACE SHAL~ BE 2" ABOVE GRADE IN GROUNC COVER AREAS, FLUSH WI TH CRADF IN i AWN AREAS, AND Fl.USH WITH AB~TTING rJXEC IMPROVEMENTS SUCH AS WALKS AND PAYING. ( AVO-lC i OCAT!NG VAL.VE BOXF:S IN LAWN O.': ABU-'ING FIXED IMPROYEMErHS WHERF FFASIRI c.) VAi VE aox -□~AT IONS SHALL BE APPROVEC BY THE LANCSCAPE ARCHITECT PRIOR -o iNS-ALLATION. GLOBE VALVES -STRAIGHT VALVES -GATE VALVES -BALL VALVES INSTAl_l~ VAI_YFS AT APPROXIMATE LOCATION S--IOW°' ON PLANS AND PER DETAILS. LOCATE VALVES IN GROUND COYER AREAS WHERE FEASIBLE. QUICK COUPLING VAIVFS OU I CK COUPLING VALVES ShALL BE SET APPROX: MA TEL Y 3' FROM WALKS, CURBS, r'EADERS, CR PAVCD ARE:AS WHERE FEAS:GLE AND PER DETAIL DRAWl~GS. LOCATE QLICK COUPLING VAl.VES IN GROUND COVER AREAS '//HERE FEASIBLE. AVOID l_OCATING QLICK COUPI_ING VALVES IN LAWN WHERE FEASIBLE. QUICK COUPLI~G VALVES LOCATED IN LAWN SHAl.l .. HAYE VINYL. COVERS. QUICK COUPLING VAIVES IN LAWN AREAS SHALL BE SET TO GRADE. QUICK COUPLING VAL YES IN SHRUB ARFAS SHA! L BE SE-J" ABOY[ GRADE. CLOSE NI PPL[S SHALL NOT BE USED. REMOTE CONTROL VALVES INSTALL REM0 7 E CONTROL VALVES AT AP~~OXIMATE LOCATION AS SHOW~ ON THE PlA~S AI\C PER DETAILS LOCAfl REMOTE CONTROL VALVES IN GROUNC COVER W~ERE FEASIBLE (SEE VALVE BOXES A80VE). ELECTRIC REUCTE CO~TROL VALVES SHALL HAYE MANUAL FLOW ADJUSTME~T. INSTALL ONE VALVE PER VALVE BOX. ND S~LICING SHALL. 8E MADE OUTSICE OF T~E VALVE BOX EXCEPT THAT MADE :NA PULL BOX. C_OSE NIPPLES SHALL NOT BE USl □. SPARE WIRES -ERMINATING IN VALVE BOXES S~ALL ~AVE T~EIR ENDS INSULATbD, THE SAME AS FOR A SP_ICE BACKFLCW PREVE~ILRS BACKFLOW FREVE~TERS WILL BE INSTALLED PER PLANS AND DETAILS. AL 8ACKfLCW FREVENTERS SHALL BE INSTALLED PER AGENCY REQUIREME~TS SPRINKLER HEACS INS'ALL -HE SPRINKLER HEADS AS JESIGNATED ON THE DRAWl~GS. SPRINKLER HEADS TO BE INSTALLED IN -H:S WORK SHALL BE EQUIVALENT IN Al I RFSPFCTS TO THOSE ITLM I 2~J. SPACING CF HEADS SHALL NOT EXCEED THE MAXIMUM INDICATE) O\J THE DRAWINGS. IN NO CASE SHALL THE SPACING EXCEED THE MAXIMJ~ RECOMMENCED BY lHf MANUFACTURER. RISER NIFPLES FOR ALL SPRINKLER HEADS SHALL BE THE SAM~ SIZE AS T~E RISER OPENING IN TH~ SPRINKLER GODY. -····---·-----· ---------------------------·--····-----· C,IEC~ V~LV[S C~~C< VALVES SHALi. BE !~STALLED WHERE IND:CATED ON DRAWINGS. IF T~c CONTRACTOR FINDS ADCITIONAL CHECK VALVES ARE REQUIRED TO PRcV='IT HYDROSTATIC RUN-OFF, HE SHALL IMMED:ATELY NOTIFY THE LA~JSCAPE ARCHITECT FOR APPROVAL OF AOD:-:ONAL CHECK VALVES. A\JTI-JRAIN VALVE A~ A\JTI-DRAIN/EXCESS-FLCW VALVE SHALL BE :NSTALLED UNDER EACH L □W-J~AINING SPRINKI.ER ~EAO WHICH IS NO-fOUIPPED WITH AN INTERNAL CHECK VALVE. W~cR~ REQUIRED, PL MPS S~ALL BE INST AL LED PER HYDRAULIC R~OJl~EMENTS AS SPECIFIED ON THE PLAN. CON-RACTOR WILL BE REOJl"<ED TO SUBMIT S~OP DRAWINGS FOR APPROVAL OF INSTALLATION PE~ A~~NCY REQUIREMEI\TS. PLMP DETAILS, IF ANY, ARE FOR CONTRACTOR'S CONVc'JJENCE fEAJ-_OC w-EN SPECIFIED, "rEAC-LCC" BY KINGS BROS.' '.NC.' OR APPROVED EOJA_, ANTI-VANDALISI/ APPARATUS SHALL BE '.NSTALLED AT EACH IRRIGATION HEAD. MO I ST JllE SENSORS WHEN YOISTURE SE~SORS ARE SPECIFIED, INSTALL ONE "CALSENSE" MDISTJRE SENSOR FCR EVERY FOUR VALVES. FOR INSTALLATION, PLACEMENT OF MOIS'URE SENSORS AND PURCHASE I NF ORMA TI ON, CONT AC-: CALSENSE 2015 CORTE:: DE:L 1',CGAL, SUI TE J CARLSBAD, CAL I FORNI A 92009 ( 619) 438-0525 MISCELLANEOUS INSTALL MISCELLANEOUS CONTROL DEVICES SUCH AS MOISTURE SENSCRS, FLOW CONTROLS, PRESSURE REGULATORS, s-RA I NERS AND DRIP I RR I GA TI O'J CONTROL ASSEMBLIES AS SHOWN ON PLANS AND PER DETAILS. OBSERVATION CONTRACTOR SHALL BE RE:SPONSIBLE FOR NO-IFYING THE LANDSCAPE ARCHITECT IN ADVANCE FOR fHE OBSERVA-:ON MEETINGS. REFER TO PART !--GENERAL FOR OBSERVA-ION SCHEDULE. TES!ING ~AKE ALL NECESSARY PROVISIONS FOR THOROUGHLY BLEEDING THE Ll~E □F AIR AND DEBRIS. 3EFORE TESTING, FILL THE LINE WITH WA-ER FOR A PERIOD OF AT _EAST 24 HOURS. AFTER VALVES HAVE BEEN INSTALLED, TES7 ALL PRESSURE WATER Ll~ES ~oR LEAKS AT A PRESSURE OF 125 PSI FOR A PERIOD OF FOUR ~ou~s. WITH ALL COLFLINGS EXPOSED AND WITH ALL PIPE SE:CTIONS C~NTE:~ _OADED. FURNISH ALL NECESSARY TESTING EQUIPMENT AND PERSONNEL. COR~~CT ALL LEAKS A~C RETEST UNTIL ACCEPTANCE BY THE OWNER DO NOT ALLOW OR CAUSE ANY OF THE WORK OF THIS SECTION TO BE COVERED BY CR ENCLOSED UNTIL 17 HAS BEEN OBSERVED, TESTED A~J APPROVED BY THE OWNER AND LANDSCAPE ARCHITECT. cLUSHING 3EFORE BACKFILLING THE MAIN LINE, AND WITH ALL CONTROL VALVES I~ 0 LACE BUT BEFORE LATERAL PIPES ARE CONNECTED, COMPLETE~Y FLJSH AND fEST IHE MAIN l.lNE AND REPA;R ALL LEAKS. FLUSH OUT EACH SECTION OF LATERAL PIPE BEFORE SPRINKLER HEADS ARE ATTACHED AD:USTMENT CF THE SYSTEM lHE CONIRACTOR SHALL ADJUST ALL SPRINKLER HEADS FOR OPTIMUM PERFO~MANCE AND TO PREVENT OVERSPRAY ONTO WALKS, ROADWAYS, AUTOMOBILES, WINDOWS AND BUILD'.NGS AS MUCH AS POSSIBLE. IE l r IS DETERMINED THAT ADJUSTME°'TS IN THE IRRIGATION EQLIPMENT WILL PROVIDE PROPER AND MORE ADEQUATE COVERAGE, THE OONTRACTO~ StlALL MAKE SLC~ ADJUSTMENTS PR!OR TO PLANTING. ADJUSTMENTS MAY Al SO INCLUDE CrANGES IN NOZZLE SIZES AND DEGREES OF ARC AS REQUIRED. LOWERING RAISEC SPRINKLER HEADS BY THE CONTRACTOR SHALL BE ACCOMl'L!SHFC WITHIN Tf:N ( 10) DAYS AFTER NOTIFICATION BY OWNER. ALL SPRINKLER ~EADS SHALL BE SET PERPENDICULAR TO FINISHED GRAJ~S UNLESS OTHERWISE DESIGNATED ON ~HE PLANS. REMOTE CONTRCL VALVES SHALL BE ADJUSTED SO THAT THE MOST REMOTc SPRINKLER HEADS OPERATE AT THE PRESSURE RECOMMENDED BY THE HEAJ MANUFAClURt::R. RUAOTE CONTROi. VAi.YES SHAU, BE ADLIUSTfl) SO THAT A UNIFORM DISTRIBUTION OF WATER :s APPLIED BY THE SPRINK_ER HEA8S TO THE PLANTING AREAS FOR [ACH :ND:VIDUAL VALVE SYSTEM. FINAL OBSERVATION PRIOR TO ACCEP-ANCE THOROUGHLY CIYAN, ADJUST AND BALANCE ALL SYSTEMS. Tl1E CONTRACTOR SHALL OPERATE EACH SYSTEM IN ITS ENTIRETY =□R THE LANDSCAFE ARCrITECT AT TIME OF F:NAL OBSERVATION. ANY IT~~s OEtMU) NOT ACCEPTABLE BY ,1,E LANDSCAPE ARCHITECT SHALL BE REWORKFC re ]ht COMPLETE SATJSFAc-:oN OF lHE LANDSCAPE ARC~ITECT. THE CO~TRACTOR SHALL SHOW EY!DENCE TO THE LANDSCAPE ARCHITECT THAT Tr[ OWNER HAS RECE I YED ALL ACCESSORIES, CHARTS, RECORD DRAWINGS, ANI) EQUIPMENT AS RfQUJR,-□ BfYORE FINAL CAN OCCUR. COMPLETION 1. ACCEPTANCE: w:-IIIN '.O DAYS OF T'-IE CONTRACTOR'S NOTIFICAIIC~ THAT THE INSTALLATION IS COMPLETE, -HE OWNER AND REQUl"<EJ AGENCIES Will. II\SPFCI lHE INS-ALLA-:ON AND IF FINAL ACC[PTANC: IS 'IOT GIVEN, WILL PREPARE A "PUNCH L.S" WHICH, IJf'0N COM~,,~TION JY THE CONTRACTOR, WILL SIGNIFY F:NAL_ ACCEr'TANCf: BY THE OW'J'R. l·IIS FINAL ACCEPTANCE WILL BE IN WR!TING rROM THE OWNER. NO ALLOWAN:E ~OR DEVIATION FRCM THE l'LANS OR SPrC.r ,CATIONS WILL GE ALLOW=]. 2. AUTHORITY: T~E OWNER OR LANDSCAPE ARCHITECT SHALL. ~AV~ !~- FINAL AUTHORITY CN ALL llfMS Of THE PROJECT. 3. CLEAN ·UP: CLEAN-UP SHALL BE MADF AS r ACH l'ORl I ON 0,-WORK PROGRESSES. REFlSE AND EXCESS DIR-SHALL BE REMOVED F"<OM T~~ SITE, ALL WALKS ANC PAYING SHAI I._ f3[ BROOM[□ or, WASHED )OWN, A's) ANY DAMAGE SUSTAINED ON THE WORK OF O HrRS SHAl.L BE REPAIRED TD ORIGINAL CONDITIONS. AT FREQUENT INTERVALS AND AT ALL . :MrS WHr.N IJJRtCTED BY TH~ OWNER, THE CONTRACTOR SHALL R[MOVE AND DISPOSE OF ACCUMULAT I O\JS OF RUBBISH ANI) 1Jr:8RIS Of Al_L KiNDS. A-TIIE TIME OF CO'.IPLETIO\J, THE ENTIRE SITE SHALL flE CIYARED OF -OOLS, EOUIPM[NT, ~U3GIS 1, ETC., ALL OF WHICH SHALL BE REMOVED FROM THE. SI ·1T, AN!) Hff. cNI l ·1r PROJECT, INCLUDl~G SURROUNDING PREM:SES, SHALL BE l_U-T l'J Vilcl:,_·,i, CLEAN CONDITION READY FOR ACCEPTANCE. 4. MA I NTENANCE: T~E ENT I RE SPR I NKI r R : l<R I GA I I ON SYST[M S' !All.. J::: JNDER f[j["[ ·p;LJfOMATIC OPERATION FOR A Pf RI Oil Dr St.Vr_N ( !) JAYS ~RIOR TO ANY PLA~TING. THE OWNER OR LANDSCAPE ARCHI-ECI RrStRVt IHF RIGHT ro WAIVE OR SHORTEN THE OPERATION PERIOD I I TEE HORIZONTAL OR VERTICAL BENO WYE -I I I ~• SEPARATORS, 15"/ FELT OR EQUAL (TYP.) NOTES: 1. CONCRETE SHALL BE 2. SEE REGIONAL STD. BEAR I NG AREAS. C) CONCRETE THRUST 3 NOT TO SCALE CROSS BLOCKING 470-C-2000 !)RAW I NG 1//--: 8 FOR BLOCKS --~-- SID~WALK / METEI, EOX WITH 1,ET[R CURB '.. 24" 12" f✓l~IMUM POTAFJLE SF:RV CF l,INE - RFCI AIMFD WATER l_lNE RRIGATION MAINLINE W:TH SLEEVE NOTE: VERTICA_ CLEARANCE OF 12" JS MANDATORY WHEN CROSSING PATH OF P. POTA8L.E WATU LiNE. INSTALi.AT ION OF RFCI.AIM:0 WAT[R IRRIGAllON MAINLINE 24" FROM FACE OF SIDEWALK WILL. PROVIDE NFCfSSARY 10· HORIZON~AL CLEP.RANCE FROM PclABJ M/,INI.INF IN THI: s-,ff, POTABLE SERVICE LINE CROSSING POTABLE SERVICE LINE CROSSING NOT TO SCALE I POTABLE MAINLINE (SEF IMPROVFM[NT DRAWINGS) • b • :: 12" MINIMJM REQL:IRED VER-ICAL SEPARATION • RECLAIMED WATER LINE IRRIGATION MAINLl~E ·--- NOTE: I 3.5 FEET a SL~EVE ALL RECLAIMED WATER IRRIGATION PIPE AND SLEEVES SHALL BE PURPLE AND LABELEC AS SPECIFIED IN: "STANDARD SPECIFICAT:o~s FO~ PRIVATE IRRIGAT:ON SYSTEMS" "CARLSBAD ~ECLAMATION ~LLES AND REGULA-l~NS FD~ CONSTRUCTION OF RECLAIMED WATER MAINS" OCTOBER, 1993 POTABLE MAINLINE CROSSING POTABLE MAINLINE CROSSING NOT TO SCALE .L•Bd1c1.p1. Archi1ac1ur■ ¥ Wil•y Gr<>up ~ ,.. .. ;;'oy w,,,;;v. t..S F bE8~ ~::,·,·:i,. ;,,: <::, ' ,.,:;,,::::..,·1_,:·-= A-·::.,.,1,..'---~..,-· .. ::.,"''· 1::. ,~;·· ~.·i;t1:(l1-;1~,;,:i , -': ,:_. # '.W:<; ENGINEER'S SIGNAIU~( Ri:::QUIR[D ON P.4CE 1 ONLY APPf'.IOV~D f"NGIN((RING PLAN CH(CK'ER D.A.ll APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS "AS BUILT" --- NAME f)/\T( TITl.~: INSPECTOR DAT( DATE INITIAL DATE ENGINf(R or WORK ; S-lll ' ' 3 '. ' . . ' TAYLOR MADE GOLF CARLSBAD RESEARCH CENTER CARLSBAD, CALIFORNIA C, M, W. D, JOB NO. ~==_,'t._..'6,,__~ 1-.2c:;'lq'f,___ JRAWING NO, 1 ~52·3t. j I ------------------------------. I ANDSCA~ING P/,RT 1 --GENERAL IHr UNfRAI CONDIT ro~s er· TH[ CONTRACT APPLY AS THOUGH WR:TTEN Hf:'lc IN_ SCOPE !Hr WORK INCLIJIJES ALL LAGOR, MATERIALS, TRANSPORTA-:ON, S[RVICES A~ci FACILITIES NECESSARY OR lNCIDF_NTAI_ TO TII[ COMPLETION OF LA~DSCAPING WORK SHOWN C~ THE DRAWINGS AND AS SPtC:FlFD. FXISI ING UI II lllc_S P',10'< TO EXC.A.V.A,TION FCR Pl.ANTING OR Pl. ACING Or Pl_AN-MATERJAI_S, I □CAI~ Al.L UND[RGROU~D LT!LITY LINES STILL IN USE AND TAKE PROPER l"'l-CAJI IONS 10 AVOID CA~AGE: TO SUCH IMPROVEMENTS. :N THE EVENT 0'-A CONFL __ [CT BETWEFI\ Si.CH I INES AND PLANT LOCATIONS, NOTIFY THE LA~JSCAPE ARCll!TECT Wf-C SHALL ARRANGE FOR THE RFLOCA-ON Of ONt 0'< T F:: OTll[R Tl-IE CO~TRACTOR ASSUMES ALL RESPONS:B:L:T'i f"OR MA\ I '"G ANY AND Al I. Rf_PA l RS f-□R DAMAGES RESUL 7 ; NG FROM WORK AS II~~:: I~ SPECIF I ED_ f'<Jl 0.~! ION Dr OTHFR WORK AND IMPROVEMENTS AJ:QJATELY STAKE, BARRICADE AND PROTECT ALL :RRIGA•:ON EOUlPMlNT, MA~~J_ts, UIJLITY LINES AND OTHER EXISTING IMPROVEMEN-s AND P'<:J~::~TY DURING ALL PrASES Of-!"HE Pl.ANTING, SO"L AM[NDING, AND GRADING OPERATIONS_ VfRlc ICAI ION Or Dl~ENSIONS AND QUANTITIES ALL SCALED DIMEI\SICNS ARE APPROX!MATf_ BEFORE: PROCEEDING W!Tli ANY WORK Tl-IE COl'-TRACTOR SHALL CAREFULLY CHECK AND VERIFY AL.l_ 'llM~NSIONS AND CLAI\T!TIES AND SHALL IMMEDIATELv :NFORM THE ,_ANDSCAr~ AHCHITFCT Of ANY DISCRE:PANCY BETWEEN -HE DRAWINGS OR SPECIFICA.TIONS AI\C ACTUAL CONDITIONS. NO WORK SHAL I_ flt· DON[ IN ANY AREA WIIERE TlcERE IS ANY SUCH DISCREPANCY UN-:L APPROVAL FOR SAM~ HAS 8ftN GIVfl\ BY THE: LANDSCAPE ARCHiTEC-OR HIS 'lEPRESENTATIVE. OUANI I TltS FOR PI_ANT AND NOT GUARANTEED. SUFFICIENT NLlMBER TO SUllMITTMS MATE:R!ALS ARE SHOWN FOR CONVENIENCE ONLY, CHECK AND VERIFY PLAN-COUN-AND SUPPl_Y FULFILL THE INTENT OE THE DRAWINGS_ CONTRA.CTOR SHALL SLEM!T A LIST OE SOIL AMENDMEN-S, 8ARK MULCH, ,f"RTII l?FRS, PLAI\T MATERIALS, SEEDS, wr-H QUAN-:-IES OF EACH WITHIN 35 CAYS OF AWARD OF CONTRACT AND SHALL RE:CE!YE LANDSCAPE ARCHITECT'S APPROVAL PRIOR TO BEGINNING WORK_ AT LEAST 15 CAYS BEFORE SCHEDULED USE, -HE PROPOSE:D SOURCE: OF TOPSOIL MUST BE SUB~!TTED TO THE LANDSCAPE ARCH:-ECT FOR APPROVAL_ THE CCNTRACTOR SHALL SUBMIT A WR:TTEN REQUEST FOR APPROVAL WHICH Sf-ALL SE ACCOM0ANIE:D BY A WR;TT[N REPORT FROM A STATE APPRCVEC TESTING AGENCY FOR AGRICUL-URAL SOIL [VALUATION WHICH STATES THAT THE PROPOSED SOURCE COMPL'ES w:TH THESE SPECIFIC-AT]Of.:S. SOILS JESTS FOR AGRICULTURAL SUITAB:LlTv AFTER ROUG~ GRAD I NG, SO I LS SAMPLES SHALL BE TAKEN FROM ENOUGH _ OCAT!ONS CN SITE JC REPRESEN~ AN ADEOUA-E CROSS SECTION OF CONDITIONS_ SCILS TEST SHALL BE PER~ORMED Bv A SO!LS TESTING _ABORATORY /FRE-APPROYEC gv THE LANDSCAPE ARCHlTECT AND THE CITY)_ THE ~CILS TEST SHALL INDiCA-C GU-NO-BE LlMJTEC TO THE ~oLLOWING: (a) ORGAl\!C CONTENT, (b; N, P, K, (c) pH, (d) EC, (e) SOIL TE:XTURE: (SILT, CLAY, SAND'.. ( f; RECOMMENDATIONS FOR AMENDMENTS, LEACHING, AND MAIN cNANC' F~R-:c I?ATIONS THE RESULTS AND RECOMMENCAT!ONS OF THE SOIL TES-:NG LABORAToRv SHALi_ SE SUGMITTED TC AND APPROVED BY THE LANDSCAPE ARCHITECT AND THE Gl [Y THE APPROVED RECOMMENDATIONS FOR AMENDMENTS AND BACKFILL SHALL BE l~CCRPORATED INTO THE LANDSCAPE PLANS PRIOR TO THE START 8F CONSTRUCTICN AND SHALL BECOME PAR-OF THE APPROVED PLANS_ ~RODUCTS SPECIFIED BY PRODUCT NAME sv 'HE SOIL LAB IN THE ~ECOMMENDAT!C~S MAY BE SUBSTITUTED w:-H "OR EQUAL" PRODUCTS APPROVED BY T~E LANDSCAP[ ARCHITEC-AND -HE CITY_ SAMPLE PL.~~ TS SftRUB AND TRE:E: SAMPLES ( 15 GALLONS AND UNDER): TYPICAL SAMPLES, THRcT EACH 01' ALL. VARIETIES AND SIZES (15 GALLONS AND UNDER) OF ALL PLANT ~ATER!ALS SHALL BE SUBMl""ED FOR OBSERVATION APPROVAL AT THE SITE A M!NIMLM OF 15 DAYS PR:OR TO PLANTING OPERATIONS. IR~E SAMPLES (24" BOX AND LARGER): ONE SAMPLE OF E:ACH TRE:E VARIETY .~NC SIZE, DESIGNATED ON THE DRAW:NGS, 24" BOX AND LARGER, SHALL BE DELIVERED TO THE PROJECT S:'E FOR APPROVAL BY THE _ANDSCAPE ARCf-ITECT PRIOR TO PLANT:NG THE CONTRACTCR S~ALL IMMEDIATELY REMOVE ANv TREES OR SHRUBS NOT ~.PPROVED THE CONTRACTCR AT HIS OPTION AND A7 HIS EXPENSE CAN RETAIN THE SERVICES OF THE LANDSCAPE ARCHITEC-TO REV:EW TREES TAGGF □ AT THE ~URSERY AND/OR AT ITS PLACE OF GROW 7 H, OR AS OTHERWISE SPECfflED JN □Rf.WINGS APPROVED SAMPLES SPALL REMAIN ON THE SI-E AND SHALL BE MAINTAINED 3Y Tl I[ CONTRACTOR AS ST AND ARDS OF COMPAR: SON FOR PLANT MATERIALS TO BE FURNISHED. SAMPLES WILL BE lNCORPORA-E:D INTO THE WORK_ 'lF 1JFCT_ION AND _:'\lJ_E'il3TITUII_()~_{ClTY __ !/\!?_F'~t;-oF< __ ~lJ:i_T_ APPRO\I~-ALSO) ALL PLANTS NOT CCNFCRMING TO THE REQUIREMEN-S HEREIN SPECIFIED SI !AL I_ BE CCNS I OE:RE:O DE:FF:CT I VE, AND SUCH PLANTS, WHETHER IN PLACE OR NO I, SHA! I BE MARKED AS REJECTED ANIJ 1-l[ • MM[O: A TEI_ Y REMOVED 0 ROM THE SITE OF WORK AND REPLACED WITH ACCEPTABLE PLANT ijATERIALS THE PLAI\T MATERIALS SHALL MEE-ALL APPLICABLE INSPECTIONS REQUIR[D BY LAW_ AL_L l'LANTS SrALL BE Or-THE SPECIES, VARlE'v, SIZE, AGE, FLOWER COLOR AND CONCIT!ON AS SPECIFIED HEREIN AND/OR AS INDICATED ON JHE DRAWINGS. U~DER NO CONDITION WILL THERE BE ANY SUBSTITUTION OF PI_ANT SPECIES, VARIETY OR REDUCED SIZES FOR THOSE l. lSTFO ON THE ACCOMPANYING DRAWINGS, EXCEPT wr-H THE EXPRESS WRITTEN CONSENT OF TrE LANDSCAPE ARCHITECT_ SUBMITTAL CF CERTIFICATES,_ T_RIP S_L:P_S AND :NYOICES 1. TOPSOIL,_ SO IL AME:NDME:NTS, AND FE:RT IL I Z~'<:_ UPON DEL I VERY OF -~AILR-IAL..S ANlc/OR COMPI_ET!ON OE ALL so;L CONDI IIONlNG AND GRADING ~LJI PRIOR TO INITIATING PLANTING OPERATIONS, THE CONTRACTOR SHAL SUBMIT TO THE LANDSCAPE ARCHITECT S:GNED COPIES OE REQUIRED CERTIFICATES, TRIP SLIPS AND INVOICES FOR SOIL PREPARATION ~ATERIALS_ IF THE MINIMUM AMOUNl"S OF -◊PSO!L, SOIL AMENDMENTS, =cRTTLTZFRS A~D OfHER SPECIFIED MA¥ER'.ALS HAYE NOT BEEN FURNISHEJ AS SPECIFIED, THE CONTRACTOR, AS DIREC-ED BY THE LANDSCAPE ARCHITECT, S~ALL INSTALL ADDIT:ONAL MA-ERIALS TO FULFILL THE MINIMUM AMCLNTS RFQUIHFD. 2. PLA'IT ,IAl,.~IAI S, IJAl,K l✓IJI CH, MU CH AND PR[ [ME:RGt.NCE: HERB!CIJES: A0 TER INSTAL.l.AT!Oi, OF Pl ANT MATf'f(TAI S FlUT PRIOR TO Iii~ 1-'~~YAINT_'IANCE !NSPECTICN, THE CONTRACTOR SHALL SUBMIT TO THE I ANl)'.-ie;A'-'r Ai,C:-llllC[ SICN[C COPIES OF THE REQUIRED CERTIFICATES, TRIPS [i0 S AN"l INVOiCl'S I CR 1111. SPLCII lLD r'LANT MAllcl1lAL. 13Al,K ,!ULCH, MUI_CC-1, --,RE-EMERCl-:~CF HfRfilCIIJIS ANll RIIATFD •-FMS IF [Hr ,11NIMJ',1 A'.!OcHTS OF THF:Sc l✓AffR!AI S HA\/F NOT flrrN FURNISHED AS '.:iPLCl -LJ, I IC: CONTllACTOR, .~S DIRECTED RY THF f_ANDSCAPE ARCHI I-Cl, 'i1A I INSTAI I AIJl;Il ICNAl MAT[RIALS TO FULFILL THE MIN!MJ'.I A,U'J'llS RFQI_Jll,rll Al I_ HCc S TIIAT li>V[ DEEN 5L!FPLIED AND INSTALLED UNDER THIS CON!"RACT :-;1tAi llr GIJAl<.ANJI_J __ c TO L_[V[ IN A HEALTIIY CONDITION FOR A r'ER I OJ 8" ONE YFAR FROM 8A ff OF 11 NAL_ Dll:ili,VA I I ON 01" P110Jl:.CT. SHRUHS, VINLS AND GROIJNDCCVERS SHALL BE GUARANTEED TO REMAIN HFAI .. T-W A\JI) vr::u1,ou~1_Y GliCWJNG I Oli 60 DAYS, Af'TLR COMPLETION OF THE s~::c1~1E □ MAINTENANCE PERIOD AND ~LNAI. O~SfRVATION_ CONTRAc:T::n SIIALL IMMEDLA.TELY REf'l_ACE ANY AND AL.L PLANT MATERIALS WHICH, '"CH ANY 111_.A.SON, Llll:S OF, IS D1\M1\GED WH'LE UNDER HIS CARE. ALL P_A\ITS f"OUND TO BE DEAD AND ALL Pl ANTS NOi 'N A VIGOROUS CONDI I JJN NOILD W!Tll!N T~E GUARANTEE PERIOD SHALL BE REPLACED WITHIN 14 l)>,YS OF WRI 1111\ ~Cl 11-!CAl ION GY Tit[ LANDSCAPE A°'CHI TECT. P __ ANIS .JS:D IOI, l?[PLAC[MEi'iT S11ALL BE THE SAME K:N □ AND SIZE AS S·'c-Cir I, J IN 11-11' Pl Md LIST. Tll[Y SIIALL BE FURN:SHED, PLANTED ANJ FERTl __ [ZED AS □R!C!NAI I Y SPfCIFIL □-ALL SUCH REPLACEMENT MATERIALS SHALL BE GLARANTEEC AS SPECIFIED FOR -HE ORIGINAL GJARANTE~J MAT[RJALS_ 03SE'<VATl □N (CITY !~SPECTOR ~UST PARTICirATE ALSO) SITE OBSERVATIONS SrAl_L ~E MADt ~y IHF LAN□SCAPE ARCHITECT_ THE C'.J'HR.ACTOR SHALL REClEST OBSERVATION 48 HOURS :N ADVANCE OE THE !IMC: AN OIJSLINA,JJON IS l,lOUl,Ell_ 03SERVATION WILL BE RECUIRED FOR THE FOLi.OWING PARTS OF THE WORK 1. INCCRPCRATION Or SOIi AMfNllMl'-NT AND FF:RTLIZ,:'< INTO THE: SOIL 2. J?ON T IE COMPLl TI CN OF GRAD I NG PR I OR TO PLAN:, NG. 3. APPROVAL OF SAMPLE PLANTS_ 4 APPROVAl OF 1'1 ANI 1.AAlcRIAI S 5. W'IEN HLlS AND S~RUBS ARE SPOTTED IN PLACE FOR PLANTING, BUT a::=oRE Pi ___ ANT!NG HOite AR[ FXCAVATED_ 6. V~RIFICATION OF FINISH GRADES_ 7_ APPLICATION OF PR[ ·EMERGEI\CE HERBICIDE. 8. W'-IEN PLANTING, A~C Al.I_ CJHR INDICAlt:D OR SPECWIED WORK, EXC::"T THE MAINTENA~CE PERIOD, HAS BEEN COMPLE 7 ED_ WRITTEN A"~'<OVAI. SHAI I_ ESTA~L 15H [][GINNING OF THE MAINTENANCE PERIOD _ 9. =1NAL OBSERVATIO~ AT THE COMPLETION OF THE SPECIFIED MAl'ITENANCE PERIOD. Tf·IS OGSERVATION SHALL ESTABLISH THE BEG!~N!NG DATE FOR lf-E ONE-YFAR GUARANTFE OF Al_l TRfES T~E CONTRACTOR OR li!S AUTIJOR!ZED REPRESEN_A_IVE SHALL BE ON THE SITE AT THE TIME OF FAC~ INSPECTION IN THE E:YENT THE CON-RACTOR REQUESTS OBSERVATION WORK AND SAIC WO~< IS SUl-lST ANT l ALLY INCOMPLETE, Tl-IE CON-RACTOR SHALL BE R::S"ONSIBLE FOR OBSERVATION COSTS OF LANDSCAPE ARCHITECT PORTAL T'.) "8RTAL U.)J\J COMPI t I JON OF H·t: FINAL OGS[RVAT I ON AND THE WORK OF TH IS SECTION, THE CONTRACTOR WII I __ flF NOTIFIED IN WRITING WHETHtR THE W:J~< IS ACCEPTABLE CR CF ANY REQUIREMEN-S NECESSARY FOR COU"_ETION AND ACC[FTA~CE. PA~T 2 -PRODUCTS ro_)SOIL -IMPORrL □ T~:: _ANDSCAPE ARCHITECT SHALL DETERMINE THE SUITABILITY OF 1o~s □IL PRIOR TO USE. TOPSOIL SHALL BE ~RANSPORTED FROM THE SOJC/CE TO ITS FIN.•I l'OSI l"!CN UNI ISS SIDCKP!I_JNG IS SPECIFJE"D ro_)SOIL SIIALL GE I-RC~ A SOLRCE OUTSIDE :HE LIMITS OF THE PROJECT SE_ECTED BY THE CONIRACfOR A~□ IN COMPLIANCE WITH THE R::OJIREMENTS SPECIFIED HERE!~. THE LANDSCAPE ARCHITECT MAY MAKE SJC~ !NSPlCI IONS ANC PERFORM SUCH TESTS AS DEEMED NECESSARY TO □::T::'<MINE THAT THE ~ATERIAL ~EEJS THl RfOUIREMENTS_ I '.PSO IL S! !ALL IIA\/l A IR I ABLE SANDY LOAM CHARAC-ER, AND BE FREE o~ ROOTS, CLODS AND src~~s LARGfR !HAN I-INCH IN GREATEST DIMENSION, POC<ETS OF COA.RSE SA~□. NOX I CUS WEEDS, STICKS, BRUSH AND OTHER LITT~R IT SHALL NCT EE l~FESTED WITH NEMATODES OR OTHER U')J~SIRABl.E INSfCTS AN!; Pl ANI illSrASF ORGANISMS_ G,A)ATION LIMITS SH.~LL BE SA~□. 50 60 PERCENT, CLAY 20 PERCENT MAXP,IUM, AND SIi T, .!C e'f_RCr_NI MAXIMUM_ THt_ SAND, CI_AY AND SILT G'<AJAT!ON LIMITS SHAI I fW AS DFf INF[) IN ASTM ll 422 P,_RWAtlll I TY RATE: Sl·ALL G[ NOT I_ESS THAN 0. 5 INCI-IE:S PE:R HOUR NOR ,1:i~~ THAN 2 I NCHtS FER IIOUI, WHEN T[ST[D IN ACCORDANCE WI TH ASTM J 2434 OR OTHFR APPROVF □ MFT~ODS- LPSO I I .. SHA.I I tit· SIJ l T Al!I f: TO SIJSTA IN TH[ GROWTH OF THE: PI_ANTS S"ECIF!ED S:) I_ AMf'_N[)M[NT S:)]_ AMENDMENT FOR BACKFILL MIX AND SOIL CONDITIONING SHALL CONTAIN A SP[CIAL □LENC OF ORGANIC FRAC-:ONS TO SUPPLY SEY[RAL D~GR~fS Of HR~AK □OW~ RATE, A PORTION OF :NORGANIC AMENOMFNT THAT RESISTS FURTHER BRf-AKDCWN, A I ONG-I AS! ING FORM OE IRON, PH OF 5_ 5 TO 6. 0, SALINITY OF 1. 75, ORGANIC MATTER ( DRY WEIGHT BASIS) MORE THAN 90%, NON -IONIC W[TTING AG[NT AND TO-AL N!TROGE:N CONTENT OF 0 5% ( I OAMIX, WII._ GliCLIIT, I OR[ST IIUMUS, OR APPROVED [QUAi.) _ ------------------------------------------------ ;,_A\IT MATERIALS ~O'IJITION: A.LL PLAf;TS SHALL HAVE A GROWTH HAS:-NORMAL TO THE s~,:c 1 fS AND SHAl_l_ tlt SOUND, Ht_AL I HY, VIGOROUS AND fF,[E:: FROM [ NSECT PESTS, Pl __ ANT D: Sf-ASFS, SUN SC,A.: .. .DS, ~RFSH fl.ARK ,A.BRAS [ c~s. EXCESSIVE ABRASIONS, OR OT~ER OBJECTIONABLE □:SFICUREMENTS_ TRE~ T~J'-J~S SHALL BE STURDY AI\C WELL "HARDENED OFF". ALL PLANTS SHA __ ~AV~ NORMAL WE:LL-DtVELOPtD BRANCH SYSllMS, AND VIGOROUS AND =I3~0US ~OOT SYSTfMS WHICH ARl NlI IHf.R ROOr NOR P0[-80UND AND A~~ =REE OF KINKED OR C!RDLII\G ROOTS_ CO~TAINE"s STOCK (1 GAL,, __ 5 GAL_, 15 GAL ___ AND BOX[S) SHALL HAYE GROWN IN :□NTA!NERS FOR Af LEAST SIX MONTHS, BU-NOT OV[R TWO YEARS_ ~8 CONTA.INER Pl A.I\TS THAT 1-AVF CRACKFI) OR flROKEN 8Af ___ l_S □= i::ARTH, W~EN TAKEN FROM Tl·E CONT A I I\ER, SHALL BE PLANTED, EXCEPT J"O'-J SPC:2IAL APPROVAL_ ~O TREES W!TII DAMAGED ROOTS OR BROKEN 3A; i_S SHA I_ BE PL_ANTED- "~UN I NG S'-IALL NOT BE DONE, FR I OR TO DEL I VERY, EXCEPT BY WR IT TEN A~~~OVAL 3Y LANDSCAPE ARCHITECT. T'<EES -A_L TREES SHALL BE CF THE SPECIFIED HE:GHT AND CROWN TO THE LAST JIVISION OF THE: TERMINAL LE:ADER AND D:AMETER. TftE ~EIGHT SHALL BE MEASURED FRCM THE ROor CROWN. -H~ DIAMfTFR SHA __ 3E MEASJR::□ 6 INCHES ( 150M~) ABOVE THE ROOT CROWN. THE HEIGHT SHALL BE MEASURED FROM T~E ROOT CROWN_ TH[ IJE:GflT OF PALM TREES S~AcL BE MEASURFD FROM THE GROUND I.INF TO TH~ SASE OF IHE GROWI'IG 3J). THE TREE SHALL STA~□ REASONABLY ERECT w:-HOUT SUPPORl_ S~'lJ3S -SHRUBS SHALL BE OF THE: SPE:C IF I [D TYPE AND SIZE, S[LECT::J =~□~ HIGH QUALITY WEI.L-SHAPED NURSERY srocK. ~~A_TTEDPLAN_T~ -GRCUND CCVER PLANTS AND OTHER FLATTED r'LANTS S~A-~ BE GROWN AND REMAIN I~ THE FLATS UNTIL -RANSPLANTED AT THE SJ T~. THE: SOIL AND SPACING CF THE: PLANTS IN -HE: FLAT SIIALL INSURE Tct:: ijJNIMUM DISTURBANCE OF THE ROOT SYSTEM A--:ME OF TRA ~SPL~.NT I NG_ SOJ _AND_ STOLOt-JS_ (_TURF ____ G~A'.:S) -TURF GRASS STOLONS SHALL BE f RI SH CL::A~ LIVING SECT!OI\S OF RUNNERS OF HYBRID BERMUDA GRASS OR HY3RID BENT GRASS AS DESIGNATED IN THE: CONTRAC~ DOCUMENTS. THEY SHA __ BE FREE OF TURF DI SEASE, INSECTS OR WEEDS, AND CAPABL_E OF HEA_THY VIGOROUS GRCWTH. FO'< ~ECHAN I CA.L OR HANC SPREAC I NG, BERMUDA GRASS STOLONS SHAI I, l'lt_ 1 TC 4 !~CHES LONG AND BEN 7 GRASS 4 TO B !NC~ES LONG. STOLONS TC BE "_ANTED IN A SLURRY MIXTLRE SHALL BE SUPPL:E □ IN SHORTER SE2TIONS AS REQUIRED_ CUTTINGS -CUTTINGS SHALL BE FRESH STOCK CUT w:-H A SHARP HAND rob_ FROM THE STEMS OF HEALTHY VIGOROUS PLAN-s OE THE SPICIES S"::CIFIED. IF NOT CTHERWISE SPECIFIED, THE LENGTH OF CUTTINGS Sci,\ __ BE IN ACCORDA~CE W!Th THE BEST IWRTICUL-URAL PRACTICE_ QUA~TITIES QUANTITIES AND TYPES OF PLANT MATERIALS FURN:SHED AND SPACING SHA __ BE AS SHOWN OR NOTED FOR EACH LOCATION ANO SHALL BE:: OF THE: SP~CIES, KINDS, AND SIZES AS DESCRIBED ON THE DRAWINGS_ QUANTITIES $HALL BE: FURNISHEC AS NE:E:DE:D TO COMPLETE WORK SHOWN ON DRAWi NGS_ I r,SPE:CT I ON ALL "LANT MATERIALS S~ALL BE SUBJECT TO THE INSPECTION AND APPROVAL OR REJECT!□~ CF THE LANDSCAPE ARCHITECT OR HIS REP~ESENTATIVE BE=ORE PLA~T)~G- PLANTS SHALL BE SUBJECT TC 11\SPECTION AND APPROVAL OR REJECTIO~. Al THE PROJECT SITE AT ANY TIME: DURING PROGRESS OF THE: WORK =o~ "OR SIZE, VARIETY, CC~CITION, LATENT DEEEC 7 S AND INJURIES_ REJECTED PLANTS SHALL EE REMOVED FROM THE PROJECT SITE I MMlD I A rf.L, y_ THE LANDSCAPE ARCHITECT RESERVES THE RIGHT TO INSPECT ROOT CONDITION OF ANY SPEC!E:S, PARTICULARLY ~HOSE: GROWN FROM SEEJ, AND IF FOUND DEFECTIVE, -□ REJECT THE PLANTS '<::"RESENTED BY THE DEFE:CTIVE SAMPLE. AGENCY REQUIREC INSPECTIONS INSPECT I ON OF PLANT MA-ER I ALS, REQUIRED 3Y CI TY, COUNTY OR ST A TE AUTHORITIES, SHALL BE A Rl::SPONSIBILITY OF THE CONTRACTOR, A"ID WHER:: NECESSARY HE SHALL HAVE SECURED PERMITS OR C~RTIFJCATES PRIO~ TO DELIVERY CF PLA~TS TO THE SITE_ SUBSTJTUT[QN$ ( CITY !~SPECTOR MUST APPROVE ALSO) SUBSTITUTIONS WILL SUBMITTED THAT ANY WILL BE: CONSIDERED VARl~TY AND COST_ ARCHITECTS WRITTEN I\OT BE PERMITTED EX Cf.PT THAT l F "PROOF l S PLAI\T SPECIFIED IS NOT OBTAINABLE, A PROPOSAi_ FOR USE OF THE NEAREST EQUIVALENT SIZE OR ALL SUBSTITUTIONS SUBJECT TO LANDSCAPE APPROVAL. SUBSTITUTIONS FOR Tf-E INDICATED PLANT MAT[RlAI S WTI_I_ BE PER',IITTED, PROVIDED ThE SLBSTITUTE MATERIALS ARE APPROVFD IN ADVA~CE OF PLANTING DATE BY THE LANDSCAPE ARCH'.-ECT AND THE SUBSTITUTIONS ARE MADE AT NO ADDITIONAL COST TO THE OWNER. Exc::~r FOR THE \/ARIATICNS so AUTHORIZED, ALL SUBSTITUTED MATE~IALS THAT ARE CF LESS VALUE THAN THOSE INDICATED OR SPEC!f"IED, THE CONTRACT PR!CF W[U_ BF.: ADJUSTED !N ACCORDANCE THE ~ROVISIONS OF T~E CONTRACT. BARK MUI.Cl-I "WALK ON BARK" OR APPROVED FOUAL SUBMIT WITH f I.RI IL I /[R -FRE>-PI_ANT 12-12 12 CONT. NITROGEN 12 CO% AVAILIABLE P~OSPf-OR!C ACID 12. 00% SOL.UGI_[ FOTASI, 12. 00% SIJlclJR 1SCIJ% CALCIUM '2_ l C% 1[RTILIZER MAINTENANCE -16-20-0 Fr RT 11 l/rR r"OR ~AIN!f"NANC[ SHALL BE 16-20-0 AMMONIUM f'HOSPHATE ]\I A HOMOGENEOUS PELLETED FORM (BEST 16-20-0, OR APPROVED EQUAL)_ NITROGEN 16. CO% AVAILABL.E PHCSFHCRIC ACID ?0_ 00% SULFUR 1 ~-CO% CALCIUM 1. 60% FERTILIZER -PLANT TABS PI __ ANT TA13S SHALL G[ TIGHTLY COMPRESSED, LONG LASTING ANll SI OW-Rf I c Ase· Wf_ I GHT OF 5. 10 AND 21 GRAMS ( ACRI FORM 20-10-5 l'l_ANTING TABLETS, OR APPROVFD FQUAI_). NJ I ROGIN ?C_ CO% AVAILABLE PHOSPHORIC ACLD 10. 00% SOLUBLE FOTASH 5. 00% CAI CJUM 2_ 60% SUI FUR 1_6C% IRON O JS% PL~NTING BACKFILL AND SOIL COND!T!ON:NG FOR BIDDING PURPOSES ON_Y ( SEE so I I s Tf-STS FOR AGR I CUL TUR AL SU:~ A-Bi"L '.tY): FOR BIDDl~G PLRPOSES, PLANTING BACKf :L_L SHALi_ BE: A THOROUGHLY Bl_tNDED MIXTURE: OF ON SITE: so:L AND AMENDMENTS AT THE ~OLI OW!N(; MIXTURF SOIL AME~CWEI\T 4. 0 PARTS APPROVED 01\-SITE SOIL 6_ 0 PARTS AGR I CUL TLRAL GYPSUM 3_ 0 LBS /Pc R CU vD OF M ! X FOR BIDD!I\G PLRPOSES, THE RATE OF so:L CONDITIONING FOR TURF AND GROUND COVER SHALL BE AS FOLLOWS: SOIL AMENDWE~T 4 0 cu YDS PER 1,000 so_ FT_ GYPSUM 75. 0 LBS. PER 1,000 SQ_ FT_ TREE STAKES --- TRE:E: STAKE:S Sf-ALL BE OF LODGEPOLE P:NE. THESE SHALL BE STRAIGHT SHAFTS, SrAVEC AND CUT Cl .. EAN AND BAl<E OF BRANCHES AND STUBS, OF UNIFORM T~ICK~ESS WITH A MINIMUM □:AME-ER OF 2 INCHES, FREE OF LOOSE: KNOTS, SPLITS OR BENDS. STAKES SHALL BE NO LESS THAN ~IGHT (B) FFET IN LENGTH FOR 5 GALLON TREES AND 7 EN ('.O) FEET IN cENGT~ FOR 15 GALLON TREES GUYING MATERIALS GUYING MATERIALS SHALL BE AS :NDICA-ED IN THE DETAIL DRAW!~GS. TREE TIES TREE TIES S~ALL BE BORDON CINCr--:E OR A0 PROVED EOUA~- PRE-EMERGE~CE HERSICIDt PRE:-EMERGEI\CE HE:RB!C!DE SHALL BE SURFLAN, TREFL.AN, DYMl:J 0~ ;PPROVED EQUAL POST-EMERGENCE HERBICIDE POST-EMERGENCE HERBICIDF SHALL Bl ROUND-UP OR EQUAL. ..;UTE MATTI~G ..;UTE MATTI~G SHALL BE OF HEMP MA-ERIAL WHICH IS HFAVY JUTE WES·! OF A UNIFORM PLAIN OPE:N WE:AVE OF UNBLEACHED SINGLE UUTE YEA~'-J AVERAGING 13C POUNDS PER SP:NDLE or 14,400 YARDS_ THE YARN S~All_ BE OF LOOSELY TWISTED CONS-RUCT:ON HAV'.NG AN AVE:RAGE TWIST J~ \JOT LESS THAN 1. 6 TURNS PER :NCH ANC SHALL NOT VARY IN lHICKNESS o= MORE THAN 1/2 ITS NORMAL □:AMETER_ -HE JUTE MESH SHALL BE FURNISHED IN APPROXIMATELY 90 POUND ROLL STRIPS. SUBMIT SAU"_E TO LANDSCAPE ARCHITECT AND CITY INSP~croR FOR APPROVAL PRIOR T □ DEL I VERY_ WOOD HEADERS AND HARDWARE LUMBER FOR LANDSCAPE: WORK SHALL BE CONSTRUCTION HEART ROUGH SAWN REDWOOD IN TrE SIZES SPECIFIED_ GALVANIZED STEEL PIPE SHA __ 3E AS SPECIFIED IN IRRIGATION SPEC,FICA-:ONS, NAILS, LAG SCR::ws AND MISCELLANECUS HARDWARE: SHALL BE: GALYAN:ZED COMMERCJAL QUALITY MATERIAL. MISCELLANEOUS FABRICA-ED ME-AL ITEMS SHALL BE MAJE FROM STEEL CONFORMING TO ASTM A 36_ HEADERS SHALL BE 2 X 4 INCH EXCEP' THA-TWO 1 X 4 INCH BOA'<JS, OR FOUR 1/2 X 4 INCH BOARDS SHALL BE SUPPLIED FOR LAMINATION 0~ TURNS AND CURVE:S. HEADER STOCK SHAI l. BF SUPPLIED JN LE.NGT·iS AT LEAST 10 FEET_ STAKES FOR HE:ADERS SHALL BE POINTED 1 X 3 I'ICrl, AT LEAST 18 !~CHES LONG JOINT SPL:C:NG LUMBER SHALL BE 1 X 4 INCH, 2 FEET LONG w;1.y Q,.,,..p . L•_•••_ ,_•p• "•chi_••_"tu•• ~,.,.., ~,,y W"~f. A.~, A 1 <.',, ,>,· <>. ,., A• .. , · I ,-,, , : !',i.flC ~"'"''' ;,r: 'i.e ·:::, .. :.-,, ,·,-,,,r,, :::,;. ··;2 0 --------------------------------------------------~ PART 3 -FXECUTICN INSPECTION: THE CONTRACTOR SHALL l'"S"~CT THE SITE AND VERIFY IHAf CONIJII IONS ARE RLADY FOR WORK. THE CONTRACTOR SHALL INS?ECT A,11_ SICNlr ICANI rACIIJRS ArHCTING IIIS WORK INCLUDING [XJSTl'-JG UT!l_!T[ES, THf. WCRK □r-OIHH, IRAlltS, r:x:s-:NG IMPROV[M[NTS AND PROPERTIES, EXISTl~G IRR!CATION l_!Nf:S, f:X:STING Pl ANT MATF~IAI, STOCK PILED MATERIALS, EXISTING GRADES, EX:STING DIMENSIONS, ETC:_ TIit: CONTRACTOR 51-ALL !IIMED!ATELY NOT!Fv -HE LANDSCAPE ARCHITECT Of-ANY DlSCRfYA~C!FS, WHICH SHAI I __ Bl: CORl,[CT[D AND Rl:SOI_YED .ACCORDING TO THE DIRECTION Or" TH[ I ANDSCAPf ARCHI le Cl PRJO', 10 BEGINNING WORK_ PROif'CI ION: !Ht CC~lllACIOR SHAU_ TAK[ EV[RY PRECAUTION TO PROTECT AND AVOID CAMAGI' 10 Sl'RINKl.c.R lff.ADS, ll?f,JGATION LI~cS, IJND[RGROIJND UTILITIES AND OTHER IMrROYEMEN-s DURING HIS GRA)ING ANI) CONDI I lONING OP[RATIONS. WEEDING Hrf □Rf ANIJ □Ulll~G PR[LIMINARY AND FINISH GRADING, ALL WEEDS A~D GRASSES SH.~LL BE Dl!G OL T BY THf: ROO rs ANll I) I SPOSfJ) OF Orf" T07f: SITE. PERENNIAL WEEDS AND GRASSES TO BE REMOVED INCLUDE, 3JT ARE NOT I ]Ml 11 0 TO, TII[ ,OI_LOWING: GERMUDA. GRA.SS, ALF ALFA, KIKUYU CRASS NUT GRASS. DALLIS GRASS, WATERGRASS r'UNCTURE V l NF, W J Rf WI f llS, CflMJ GRASS[S JOHNSON CR,A.SS, l✓USTARC PL.ANT, ST. AUGIJS :Nf GRASS PL AN I l NG AllEAS SI ALL GE 1flEE OE WEEDS AND OTHER EXTRANEOUS MA.TERI.A.LS TO A DFl0 Tf-< OF 1? INCHfS tlcl OW f :NISH GRADE:: 13fXOR~ TOPSOIL '//ORK. Wff'D SPRAY rOR ~YDRCStLD[D AR[AS WEED ERADICAT!C~: WEED ERADICATION FOR THE HYDROSEEDED AR~AS Ar lfR IRRTGATICI\ l~STALLAT!ON BUT BEFORE PLANTING INSTALLATIJ~, THE CONTRACTOR S~All. IRRIGATE THE Hv □ROSELDLD AREAS AT LEAST ONCE DAILY OV[R 14 TC 21 CALENDAR DAYS '0 GERMINATE EXISTING WE::J Sr f llS_ Al L. OW WE[D SltCS TO GROW UN, IL THEY REACH A MAX I MU~ HEIGHT OF TWO TC T~RFE I NCHFS ( ?'' -:)") _ THEN, APPLY I lie_ POST EM[RGENCE ~ERBIC!DE PER MANUFACTURER'S SPECIFICATIONS A'I) INSrRUCIIONS TES-SOIL ,OR TOXINS "RIOR TO HYDROSEEDII\G OR PLANT I NG, APr'RCX I MATFI Y TWO ( 2) W[CKS Ar I li~ APPLICATION. GRADING AND SOIL PR[PARAT!ON MOISTURE CONTENT: THE SOIL SHALL NOT BE WORKED WHEN THE MOISTJRE CONl~NT JS SO GREAT TIJAT EXCESSIVE COMPACTION WILL OCCUR; ~O~ WHEN IT IS SO DRY THAT DUST WILi_ FORM IN Tft[ AIR OR THAT C_OJS WILL NOT BREAK REAC!LY. WATER SHALL BE APPLIED, IF NECESSA'lY, TO PROVIDE !□EAL MC!STURE CONT[NT fOR l'LLING AND FOR PLANTING HEREIN SPFC!F!FC_ IF Tl,E MOISTURE CONTENT OF THE SO I c.. S~OULD REACH SUCH A LEVEL THAT WORKING IT WOLL□ CESfROY SOIL STRUCTURE, SPREADING ANJ GRADING OPERAT!C~S SHAl.L RE SUSPENDED UNTIL THE: MOISTURE: CJ')T~NT IS INCREASED OR REDUCED TO ACCFPTA8 c-_ f:Vf:l_S ANO THE DESIRED RESULTS ARE LIKELY TO BE OBTAINED_ TOPSOIL PREPARATIO~ AND CONDITIONING: UNLESS OTHERWISE SPECI=IED ON THE: PL_ANS, EX!STlNG--dN---sif[-SoIC-SHALL SE USED WH~N lM"8~TED TOPSOIL IS SPECIFl[D, THE THICKNESS OE IMPORTED TOPSOI~ S,-iA~-3E SHOWN ON THf. Pi_Ai'.S, OR IF NOT SHOW, SHALL BE 6 I NCH ES Tel I CK THE EXISTING SOIL BELOW SUBGRADE FOR :MPORTED TOPSOIL S~A_L BE SCARIFIED TC A DEPTH OF 6 INCHE:S PR:OR TO SPREADING TO"S81L ON~SITE TOPSOIL S~ALL BE SCARIFIED AND CULTIVATED TO A =!~ELY DIVIDED co~□IT[ON TO A DE:PT OF 6 INCHES MINIMUM BELOW =r'IISH GRADE_ DURING THIS OPERATION, ALLS-ONES OVER 1 INCH I~ GREATEST DIMENSION S~ALL BE REMOVED_ PRELIMINARY GRAD!~G: PRELIMINARY GRADING SHALL BE DO~E I~ SUCH A f.i~)iNE°r, As TC A~ TIC I PA TE THE FIN I SH GRAD l NG EXCESS SOL SHALL BE REMOVE:□ OR RE:D!STRIBUTED BEFORE APPL:CATION OF EERT!Liz:::, AND MULCH_ WHERE SOIL. IS TO Bf: REPLACED BY PLANTS AND MU_C,, ALLOWANCE S~ALL BE MADE SO THAT WHEN FINISH GRADING HAS 3::GUN, THERE SHALL GE NO DEFICIENCY IN THE SPECIFIED DEPTH o~ WJ_CHED PLANT I NG BFDS- MOUNDS, __ flFRl>'S: MCUNIJS, WHEN DES I GNA-ED ON THE PLAN, S IA __ BE INSTALLED -o THE SATISFACI ION o~ THE LANDSCAPE ARCHIT[CT_ MOUNDS SHALL BE CCNSTRUCTED TO ACHIEVE A SMOOTH AND UNIFORM ===ccT WITHOUT ABRUPT CHANGES IN GRADE. OP-:MUM SLOPE OF MOJ'"JS IS 5 l_ MAX I MUM SI CPI: CF WOUNDS IS 3: J _ ROUND TOP AND BOTTOM o~ "10UND SLOPES. MOUNDS II\ LAWN AREAS SHAU. m: GHAIJfl) IN SUCH A ~ANNcR TIIAT THEY 1-/AY EASILY GE MOWED. FERTILIZING ANC SOIL CONDITIONING: -HF Pl ANT I NG AREA S~A-L BE: BROUGHT TO PRELIMINIIRY GRADE BEFORE CON □If!ONING MATERIALS SP[CIFIED_ SPREADING THE FERTJ_IZERS OR FE:RTILIZING ANC CCNDITIONING MATER:ALS SHALL BE MECHA\JlCA_LY SPREAD A I A UNIFCRI✓ RAT[. TIIE QUAN-:-IES OE MATERIALS ~~CESSARY FOR THE PLANTI~G AREA SHALL BE AT -HI SI le: ANI) SHAI __ L 3~ 1/':RIFIED BY DELIVERY TICKETS FURNISHED TO THE LANDSCAPE ARCH11=cr 3EFORE SPRr All I NG TILL IN SOIL CCND!TIONINC MATERIALS -o A Of:PIH A.ND IRRIGATE Tl·ORCL:GHLY AFTER APPL:CA-ION WITH WATER USING INTER~ITTENT PONIJING (LEACIIING)_ Of 6 TO B INCHE:S 4 TO 6 l'IC'-IES OF "AS BUILT" iJATr BARK MULCH SHALL BE SAMPLE TO LANDSCAPE PRIOR TO DE:LIVERY. ARCHITECT AND CITY INSPECTOR FOR APPROVAL ~-~- \)II ~,_'Ill ENGINEER'S SIGNATU,E R:OUIRED ON P•GE 1 OSL"f APPROVED. APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS :'~AM['. TiTI F: GYPSUM GYPSUM SHALL AGRICULTURAL AGRICULTURAL BE A CO~MERC!ALLY PROCESSED AND PACKAGED \I GYPSUM ( CAS04, 2H20) SUCH AS B[N FRANKL l N ~ GYPSUM CR APPROVED EQUAL. MU_L_~_li_j£Q_R_ HANC SE~p_l_[::!~_Qf_ [,_i\WN) MULCH SHALL BE COWMERCIALLY BLENDED ORGAN:C TOP DRESSING WITH NITROGEN ADDED SLCH AS KEU.OGG TOPPt:R, 1. __ BR :URF SPREAD OR APPROVED EQUAL. FERTILIZE:R -PRE-PLANT 12-12-12 .. , -----·--··-·-··· ··-·· .. ,.,_ ~ FERTILIZER FOR PRE-PLANTING SHALL BE A HOMOGFNOUS PELLETED FORM CONTAIN I NG EQUAL A~OUNTS OF NITROGEN, PHOSPHOROUS, AND POTASH PLUS SULFLR AND CALCIUM. ( BEST TR:PL.E TWELVE 12-12-1:>. CJ~ APPROVED EQLAL). --ENGINEERING PLAN CHECKER [)ATE DATE INITIAL REVISION DESCRIPTION ENGINEER OF WORK RLVILWC.D BY: INSPECTOR DATE .... -. . -·· SHE.E- 4 CITY OF CARLSBAD Pl .. /HH.JING DEPAPTMEN- SHElTS 12 ,TAYLOR MADE GOLF DATE I.\JITIAL D/,TE l/'.11-1.~-1 DWN BY: _ _,_ __ -----f----L------1 I \. H Kl) AY: 'RVW[) BY: OTlffR APPROVAi CITY APPROVA.L CARLSBAD RESEARCH CENTER CARLSBAD, CALIFORNIA ii PROJ[CT NO_ , . ~RAWING NO_ I ' C. M _ w _ D _ JOB NO_ ~==~9?..r:il,'..::-:.....Zl!e."l:z._:i'( __ ------------------------------------------------------------------------------------' ------·-------------------------------------- . -------------- 0 H, II 1/tR Pf,[ -PLANT 12-'2--1? SHA __ L GE APPLIC:D AT THF RAT!:: OF 20 POUNDS I',-~ ', 000 SQUA"(E ,EET. .A" Ir R I FACH I NG ( AGOVE), APPL. Y T 11[ PRE PL.'.NT FERT I LI ?ER ANO T [ LL I,~ TO A DEl"TH or 6 TO 8 I NC HES AND IRRIGATE THOROUG~LY A=TFR APPLICATION WITH 2 TO 4 INCHES OF WAflR USING INTERMITTENT ~oN □JNG rH[ -IIORCUGH~ESS AND COM~ UlN[SS OF THE CULT I VAT ING AND i I\COIPORA TI ON Of'" THE SO I I CONJ l Tl ONERS/ilMENDMENTS SHALL BE: ACCEP-ABLE 10 IHE LANDSCA~E ARCHITf-CT SLOP[S 2:; AND STE~"ER, OR AS PER THr: l)RAWINGS, OMIT SOIL CON)! I :ONF:R A~~LICATION A'<D TILL:NG. FINlSH GRAIJ[ Ac 7 ER FERTILJZ:NG ANIJ CONDITIONING, THE SOJI_ SHAU_ G~ WATEREb ~NJ Al.LOWED TO SET-LE TO PROVIDE: A STABLE SURFACE, NOT OV[Rl_Y DE!-;SJFl~D TO THE fXlr:N-TIIAT IT WILL PREVf'JT AU,ATJON AND WAlrR :Nr [LTRATION. AFTER lHf: SO[L IIAS DRIED OUT TO A WORKAcll..E: CONDIT: ON, TH~ PLANT I NG AR~AS SHAI I elf. REGRADED, '<AKED, AND SMOOTI-IED TO THE REOU I Rf.I) G'iJ,DES A~D CO'JTOURS. THf f IN I Sf-GRADE SHALL BE SMOO'-H, UN I FORM, A~D FR~E OF ABRUPT GRADE CHANGES AND OEPR[SSJONS -o E~SUR~ SURFACE D~AINAGE. TH~ FlNISIIED GRADE BFI.CW ADJACENT FAVING, CURRS OR HEADERS SHALL BE 1 INCH IN L.AWN AREAS AND 2 iNCHES IN SHRUB OR GROUND CCVfR A.Re AS. FINAi_ r :NISI· GRADES SHALL INSURE POSITIVE DRAII\AGE OF ~HE SI Tc WlTH Al I SURF.ACE DRAINAGE AWAY FROM fJULDlNGS, WAL_S, AND TOWARD ROAIJWAYS, DRAINS AND CATCH BAS I NS. LNLESS OTHERWISE DFSIGNAIED, PLANTING SURFACES SliALL BE GRADED WITH NO LESS THAN 2 PERCENT SURFACE SLOPE ( 1/4" PER FOOT) FOR POSITIVE DRAINAGE. FJNJSY SURFACES SHALL BE Cl_tAN AND SUJTA3_E FOR PLANTING. FINAl. GRADES Sl!AL_ BE ACCEPTA31 E -o THE _ANDSCAPE ARCHITECT BEFOR~ PLANTJ~G □~ERATIONS WI~L BE ALLOWEJ TO fJEGJN Pl ANTING GENERAL: -HE TYPES, s:?rs AN) QUANTITJES OF PLA~T MATER:ALS S~A[( ·jt AS CALLED FOR IN THF ?LANS A~C SPECIFICATIONS_ ALL PLANTS WILL BE INSPECTED PRIOR TO PLANTING, INCLJJJNG PLANTS PREVIOJSLY APPROVE) AT THE ~URSERY. T~E CONTRACTOR S~ALL BE RESPONSJBLE f"OR TIE CONDITICN OF ALL PLANTS, PLANTED OR OT~ERWISE, UNTIL ACCE:PTANCE. PLANTI\IG SHALL BE "~RFORMED WIT'-1 MATE:RIALS, EQUIPMENT, AND PROCEDURES FAVCRABLC: TO THE OPTJMUM GROWTH OF TIIE PLANTS AND IN COMPLIANCE WIT~ THESE PROCEDURES. EXCEPT AS NOTEC FOR SPECIMEN PLANTING, ALL PLANTING SHALL FOLLOW THE COM"LET:ON CF IRRICATICN SYSTEM. TI ME OF "LANT [ NG: NO PLANT I NG, EXCLUD [ NG s~r:c; MEf-PLA 'HI NG, SHALL B~ DONE ·u-~-T IL AI_L OPERAT I D'JS : 'J CCN.!U~CT I ON WI TH THE INSTALI_ATION OF -HE SPRIN<LER SYSTEM i-lAVE BEEN C □MPLETEC, FlNAL GRADES '-!AVE BEFN ESTABLISHED, TH~ PLANTING AREAS HA'✓E BEEN PROPERLY GRADED ANO PREPARED AS ~ERE IN SPECIF I ED, AND fHE WORK APPROVED BY -HE LANDSCAPE ARCHITECT OR HIS REPRESENTATIVE. PLANT PROTEC-ION AND STORAGE: THE CONTRACTOR SHALL KEE" ALL PLANT M/',T~RIAL-□E:L!V[":FO -□ THE SITE :NA HEALTHv CCNOITJON FOR PLANTJNG. PLANTS SHA_L NOT BE ALLOWED TC DRY ou-. BAR~ ROOT s-□CK SHA_L BE SEPARATED AND "HEELED :N· MOIST EART~ OR OTHER SUITABLE MATER:AI_ BALLED AND BURLAPPED Pl.A\ITS SHALL HAVE THE ROOT BALL COVERED WITH MO I ST SAWDJST, WOOD Ci-I I PS, OR OTHER APPROVED MATER:AL. LAYOLT AND PLANT LOCATION: DETAIL~D LAYOUT WITHIN THE: PLANTING ------------------------AREAS SHAL~ BE PERFORMED av T~E CONTRACTOR AND APPROVED 3Y THE LANDSCAPE ARCHITECT PRIOR-□ PLANTING. THE: LAYOU-OF LOCATJONS FOR PLANTS IN PLACE ANJ OUTLI~ES OF GROUNDCOV~~ TO BE PLA\JTED SHALL BE A~PROVFD CN f~E SITE BY THE LANDSCAPE ARCHITECT, PR:OR TO THE:JR P_ANTING. ALL SUCH LOCATIONS SHAcL BE CHECKEJ FOR PCSSJ3_E INTERFER~NCE: wr-H EXJST]NG UNDERGROJND PIPI~G. ~~!OR TC EXCAVATION OF rlOLES IF UNDERGROLND CONSTRUCTION OR UTILITY LINES ARE E:\JCOUNTERED 1\1 THE EXCAVATION OF PLANTING AREAS, OTHER LOCATIONS FOR THE PLANTII\G MAY BE SELECTED BY THf. 1.~.\JJSCAPE ARCHITECT. DAMAGE TQ Ex:STI~G UTIL[T:E:s SHALL GE THE RES~ONSIBILITY OF THE CONTRAC-OR. IHE FIRST ROW OF PLANTS IN AREAS DESIGNATEC FOR CENTER TO CEN-ER SPACING OF ~~ANTS SHALL 3E LOCATED AT ONE-~ALF OF DESIGNATED SPACING FRO~ THE FDGE OF Tl!E AREA. SPE:CIME:~ PLA\JTJNG: SPECIMEN PLANTS IN BOXES 24 lNCHES ANO LARGER SHALL flE P°LA~TEii°ElEFORE INSTALLATION oF· LATERAL JRRIGATION LINES. IRRLATION LINFS C::ONFLICTJNG WITH SPEClMEN Pl ANT LOCATIONS SHALL BE RE ROUTE) TO CLEAR T~~ ROOT BALL. PLAN-I NG TRc E.S, SHRL;BS A ND VINES PLAN-ING HOLES SHALL BE APPROXIMAf~LY SQUARE WITH VERTICAL SIDES TWICE THE WIDTH AND NO DEEPER THAN T'-IE DfPIH OF THE PLANT CONTAINER OR BALL ( ?X CONTA:NER D[PTH FOR DEEP WATERING DEVICE 0~ fJREATHE:R TUBE), AND SHALL BE WIDt~ JF NECESSARY TO PERMIT '-IANDLING AND ~LANTI~G WITHOU-II\JURY OR BREAKAGE OF THE ROOT BALL 0~ ROOT SYSTE',1_ ANY PLANT W:TH A BROKEN OR CRACKED ROOT BA~L 3~FORE OR DUR l NG PLA~ TI NG SHAI .l.. NOT GE PLANTED. CONTA:NERS SHALL BE CPENEJ PLANT ROOT JS NOT INJ~RED. IOOSfNED CR CUT BACK AFTE~ HOLE. AND RE~OVED IN SUCH A MANNER THAT THE 8ALI_EC PLANT WRAPPINGS SHALL BE PLANT IS POSl-:ONED I~ THE PLANTING l~SPECT ROOTS PRIOR TO PLAI\TlNG. ALL CJRCLJNG ROOTS SHALL BE CUT OR OPr.NED UP A~D THE: FOUR SlDES OF fH? ROOT BALL CUT AP~ROXIMATELY 1/4 of· AN INCH. AL_ PLANTJ~G HOLES SHALi 8~ BACKFILLE:D WITH A PREPARED SOIL ',!IX_ AFTER PLANTING, THE PLANT SHALL BE PL.U'-18, WI n, n,:: ROOT CROW\J SLIGHTLY HIGHfR ( :" SHRUBS. 2" TREES) O'l A-I rs NATURAL GROWJNG DEPTH WITH RESPECT -o FINISH GRADE. P_ANT:NG SHA_L BE GCVERNFD ~y THE FOLLOWING REQUIREMENTS: 1. DIG ~LANTING HOl~E (PER ABOVE) 2 X WIDTH AND 1 X DEP[H OF fHE PLANT ROOT EALL OR CONTAIN~~- 2. THE PLANT SHAI I. BE SET A""ROXJMATELY AT THE CENT~R OF THE HOLE. 3. PREPARED SOIL ',IJX (PLANTING BACKFILL) SHALL BE DEPOSITED AROUND THE PLANT IN THE REMAINDER OF THE HOLE ro FINISH GRADE, WITH f"ERTILIZER -PI_ANI TABS ~LAC[D AT MID-DEPTf-. i.¾GSf1T5 "_OT 1•20 4. THE BACK" II I_ MAX SHALL BE Tf'OROLJGHL_Y WA Ir 1,-st I llr_D AND ADDITIONAL ~REPARCI) SOIi_ MIX ACDED TO ,ILL .'.NY REMAINING VJJIJ BEL.OW fINISI GRADE. 5. A CIRCULAR WAffRINC: BASIN SLIGIITLY LARGU-i THAN "Hf: l'I A.~TING HOI r, 4 l NCHES H: G~, SHA! I 1-lf I cl T AllOUND THE PLAN-. THE 30TTOM QC-THE fl AS [ N SI IALL EE AT APr'ROX l M•, Ir r : NI SH Gl,A)E OR SL I GHTL y LOWER. MUI CH SHALL DE SPREAD AT I -A,;-J If;CHES DEEP IN TIIE BAS l N. 6. THt: PLANT Sl1ALL EE GJYFD ANI) STAKE::D AS SPECFJED. 7. THE AREA AROUNI) THE ~LAN~S SHALL BE REGRADE) TO f-IN I SI, G~ADE. THE EXCESS SOIL SHALL fl.' DISPOSED OF BY TIIE CO'-lTRAC-□R. B ALL Pl_ANTS SHAI L BE THOROUGHLY 1/ATERF:D IN TO I HF. f"UI__L □[~TH OF EACH PLANTING HOLE I~MFDJATE:I__Y Af"TE~ PLANTING. PLA~TING CF VINES AI_I_ VJNES SH~--L BE REMOVc) rROM ST.A<~S. UNTIED, AND SECLRf:l.Y FASTtNE:D lN AN APPROVED ',!ANNtR 10 WA_I_, FENCE, OR OTHER SURFACr NEXT ro WH]CH TH[V ARE P_ANTF □. PREPARED BACKFILL ALL sol L BACKc I I l_ IN p ITS FOR TREES, SHRURS, V l Nr.S AND FCR PLANTER BOXES SHALL Sf A PR[PAR[C SO]_ AS srECIFIED. rHf PREPARED SOIL S~ALL BE MlXED :NAN ACCURATELY PRO~ORTJONED MEASJRJNG CCNfAlNER SWCH AS A WHEELBARROW. MIXING IHE BACKFI~L MIX 8UTSIDE OF A CONTA[NfR OR ON OPEN GROUND ADJACENT TO PI __ ANT PITS IS NOT ACC~PTABLE. UNJSf □ FXCAVATE:D SOIL SHALL BE CLEANEJ UP AND DISPOSED OF OFF-SITE. Pl.ANT I NG -ABLETS PLANTING -ABLFTS SHALL BE P_ACED IN MJJ-DEPTH IN EACH PLANTING HCLE AT THE FOLLOW]NG RATE 1-5 GRAM TABLET PER LII\ER AND FLAT SI7E PLANT 1-21 GRAM TABLET PER GALLON CONTAI~ER. 3-21 GRAM TABLETS PER 5 GALLON CONTAINER. 4-21 GRAM TABLETS PER 15 GALLON CO~TAJ\IER. 1-21 GRAM TABLET PER EACH 4 INCH OF BOX S:/F PLANT!~G OF GROUNJ COVERS ALL GROJND COVER 0 _AN-S SHAL_ BE EVENLY SPACFD TO PRDOUCE A UNIFORM EFFECT ANJ STAGGERED IN ROWS AT THE lNTERVA_S INDICAfED ON THE JRAWINGS ~LANTS SHA __ BE MUI..CHfD AS SPECJFlcD AND WATERED IMMEDIAIE_Y AFTER PLANTJNG OPERATIONS ARE COMPLETED, AND SOIL SHALL BE KEPT CONIINUAL_Y MO[ST BY WATERING AS OFTEN AS REQUIRED MUI.CHJ~G ANO FIRST WATERING 5HAL_I_ BE DONE: lN CONJLNCTJON WITH Ti-IE PLANTING BUT NOT LATER 'HAN THE SAMF DAY THE P~ANTS A~E PLAI\TED -HE GROUNDCOVER PLANTS SHALL BE PLANTED SJFFICIENTLY JtEP TO COVER AL_ ROOTS AND A 5 GRAM P_AN-ING TA3_ET SHALL BE PLACED IN EAC~ PLA~TlNG f--CLE AND SHALL Be IMMECIAT=_y SPRINKLED AFTER PLA~TJNG UN-IL THE ~NT:RE AREA JS SOAKED TO THE F~LL DEPTH OF ALL HOI_ ES. THE GROUNDCOVER PLA~TING AREAS SHALi BE HANO SMOCTHED AFTER PLANTING TO DROVl □E AN EVEN, SMOOTH FINAL "!N'.SH GRADE. PLAN! STA<iNG ANC GUYING ALL TREES, :5 CAccON AND SfJALLE°', SHALL BE S_TAK_ED WITH_TWO wooc STAKES THE STAKES SHALL 8E DRIVEN IN PLUMB AND SECURE. SPECIAL CARE SHAL_ sr TAKEN THAT T~E DRIVING I~ OF THE STAKES DOES NOT DAMAGE THE TREE RCOTS OR RCOT BALL. TREE TIES SHALL BE FAS-ENED TO EACH TREE AND STA-<E BV 1.00PJ\IG F:GURE s· s w:-H THE l'JSJDE DIAMETER □• THE TIE AT 2 OR 3 TIMES THE □!AijETER OF THE TREE AND 3Y NAILJNC THF BACK OF THE TIE TO THE STAKE. (SEE DE:TAJLED JRAWINGS.) ALL TREES 10 6[ GLYED SHALL BE 24" BOX AND _ARGER AS DESIGNATED ON -H[ □-~~.~S. ( SEE D~TA _ , .. E.IJ □RAW] NGS. ) ------------------ THE STAKING AND GUYING SHALL BE ACCOMPLISHED IN suer A MANNER AS TO INSLRE THE PROPER AND HEALTHY GROWTH AND THE SAFETY OF THE "I.ANTS, P,ROPE:R-Y, AND THE PUEL IC PRUN;NG PRUNING AFTER f'LANTJNG SHALL BE REQUIRED ON A_L TREES, SrlRUBS, ANO VINES WHEN NECESSARY TO PROVIDE: THE SPECJ 0 JED OR APPROVED STANDARD SHAPES, FORM AND/OR SIZES CHARACTfRISTIC TO EAC~ PLANT. P'lUN:NG MAY INCi.UDE: THJNNING, TOP?JNG. A,\D/0~ CUTTING AN) SHALL BC: UNDER TH~ DIRECTION OF -1,E LANJSCAPE ARCHITECT. curs OVt:R 3/4 INCH IN DIAMETER SHALL BE ~AIN-ED WITH AN APPROVE) TREE SEALANT. LAWN PLANTJ\JG G~NERAL. B~•ORE PLANTING LAW~, A __ SPECirifD SOIL PREPARATION AND FINE GRAJ]NG Sr.AI_L 3[ COMFLETc). PRIOR TO Pl A\JTING CF LAWN, THE AR~AS SHAI I r3E 0 JN:SH GRADED SMOOTH WITH A UN!FCRM GRADE: BETWE~N WALK, CURBS, SffPS AND BUILDINGS. THE CO~TRA:IOR SHAI I 03TAIN APPROVAL OF FI~JSH CRAIJFS PRIOR TO PLANTING OF LAWN. SEED LAWN PLANTING ~AY BE ACCOI/Pl_JSHED BY DRY METHOD OR HYJROSEEDING. SEEDING SHALL NCT BE PtRFORMfD WHEN THE WINJ VE_oc:TY EXCfEl)S 5 I/ILES PER HCUR 0~ IS DEIRIMENTAI TC TliE UNIFORM CJSTRJBUTIO~ Of THE SFED. DRY SEEDING LAWN THE ARE:A TO BE SEEDED SHALL BE L.IGHTLY RAKED TD PROVIDE A SEED BED THE REQUJRED SEED MIXTURE SHALL EE SOWN UNIFORMLY A: THE SPECJF:EO RATE. SEEDING $HALL BE DO~E :N TWO OPERA-:ONS WITH THE SPR~AOER SET TO SOW ONE-HALF -HE SPECIF:EO A~OUNT IN EACH OPE°'ATiON. THE SECOND SOWING SHALL BE AT RlGIIT ANGLES TO THE FIRST. AFT~R SOWING, THE AREA SHALL BE F'✓ENLY COVERED WITH AN APPROVED I/ULCH, AT fHE: RATE OF ONE CUBIC FOOT OF MUI.Cl! PER ONE HUNDREJ SQUA~E FEET THE _AWN AREA SHALL BE WATERED IN A MANNER SO AS TO NOT TO CAUSE SURFACE EROS I ON. NEWLY SEEDEC su"~ACES SHALi. BE K[PT MOIST CONTINUOUSLY THROUGHOUT THE GERMINATION ~ERIOD. RE-SEEDING OF BARr: AREAS Sl1ALL BE CONE THJRrY ( 30) DAYS AFTER IN:TIAL APPLlCATION. HYJROSEFCING ,_AWN AND OTH~R GROUND COVERS .. , __ ,, . . HYJIWSr[CING SHALL BE APl"_JED IN IHF AREAS l~DICATED ON THE D~AWlNGS AND AS PER I/IX CALLED FOR. I I~ SEED, FERT IL l ZER, FI Bc·R AND CT HER MA-ER I ALS IN -HE SLUR~Y MIXfURE SI-ALL 3E AS SPECI~IED. Al I MATERIALS SHALL BE CF SJCH C~ARAClER THAT THEY WILL DISPERSE INTO A UNIFORM SLURRY WHEN MIXED WIT~ WAT~R. Tf--E MIXTURE S~ALL 3E SUCH THAT AN ABSORBENT POROUS MAT WJL_ BE FCRM~□- ALL MATERfALS MUST GE AVAILABLE FOR INSPFCTION PRJOR TO APPLlCATIO~. WrIGHTS AND CON-ENTS OF CONTAINERS SHALL BE CLEARLv IDENTJclED. A GREl:\I COI_ORING ADDITIVE: SHA_L BE USED IN THE: SLU~RY FOR VISUAL !NSPECTJON PURPOSES. lHE SLURRY SHALL EE APP_JED UNCFR PRESSURE AT THE SPECJFl~D RATES. ARtAS TO BE PLA\JTED BY THIS METHOC SHALL BE MOISTENED TO A D~PTH OF 5 INCHES BUT SHALL NOT 3E SURFACE WET AT THE TlME OF APPLICATION. TH~ SLURRY PLANTED AREAS SHALL BE KE:?T MOIST DU~JNG THE GERM:NATJON PERIOO, BUT PUDDLI~G S'-IALL BE AVOJDFI) SPECIAL CARE: SHOULD BE EXERCJSFI) BY TH~ CONTRACTO~ IN PRE'✓ENlJNG ANY OF -:-HE SI URRY GE I NG SPRAYED I NS I DE ANY RESERVOIR BASIN OR ONTO CONCRETE DRAINAGE DITC·IES AND CHA\JNELS Wf--lCH MAY IMPEDE THE FREE FLOW OF RAIN OR IRRIGATION WATE:R. ANY SLURRY SPILLEC INTO RESTRICTE.D AREAS Sl·IALL BE C_EANED UP .~T THE CONTRACTOR'S EXPE\JSE TO THE SATISFACTION OF THE ~ANDSCAPE ARCHITECT OR OWNE:R. hYDROSEED AREAS Sl1ALL BE KEPT MOIST AT ALL -[MES FOR 20-24 DAYS AFTER ?LANTING OR UNTIL THE NE:W GROWTH OF THE PLANTS ARE: SLFFJCJEN-LY WELL ESTABLISHED AS PER LA\J)SCAPE ARC'-IITECT' S APPROVAi ... HYOROScEDED AREAS SHALi, 8E PROTE:CTE:C AGAINST FOOT TRAFFIC AND OTHER USE iMMEDIAT~LY AFTER HYDRO-SEEDING JS COMPLETED BY PLACING WARNING SIGNS AND TEMPORARY TWINE AND FLAGGING AROUND THE AREAS. Rl-HYDROS[EDI~G OF BARE AREAS SHALL BE DONE: -HIRTY (30) DAYS AFTFR I\JIT'.AL APPLICATION. WH:O SP~AY, WEED REMOVAL, AND '<E-HYDRCSEEJJNG OF AREAS OF EXCESSIVE WEED GROWTH SHALL BE DONE THIRTY (30) CAYS AFTER lNlTIAL APPLlcA·1of-. HYDROSEED MATERJALS FIBER MULCH 2. COO O LBS/ACRE F"ERTILIZER ( 16-20-0) 300. O LBS/ACRE 8 l NCER 140. 0 LES/ACRE STOLONS/SEEIJS _ (AS SPECIFIED ON PLANS) SOD LAWN Pl_ANTl~G -HE TYPE AND THICKNESS OF SOD A~O -HE AREAS TO BE SODJED SHALL BE IN ACCORDANCF WITH T~E CONTRACT DOCUMENTS. SUBGRADE FOR SOD SHA_L BE THE s~ECIFJE:C THICKNESS OF THE SOD BELOW FINISH GRACES SOIL CONDITIONING ANO FINE GRADING SHALL BE COMPLETED BEFORE SODJING. NO HEAVY EQ~IPMENT SHALL OPERA-E OVER THE: SUBGRADE AFTER G~ADJNG IS COMPLE:TE:C. THE SU8GRADE: SHALL BE MOIST BUT ~OT WET WHE~ SOD •c LAID SOC SHALL BE _AID WITH CLOSELv FITTEJ JO:NTS, A~D -HE ENDS QF -HE s-RIPS SHALL BE STAGGERED. OPENINGS SHALL 3E PLUGGED WITH SOD OR TOPSOIL. WITHIN TWO HOURS AFTER JNSTALLING SOD AND BEFORE ROLLING, THE SOC SHALL BE LIGHTLY IRRIGATED. ALL SEAMS AND JOINTS Sf-Ale THEN BE ROLLED UNTJ~ THE SOD JS WELL EONDED TO THE SUBGRADE. THE AREA S~ALL THEN BE WAfEREC THOROUGHLY TO ~ENETRATE T~E SUB-SOIL AT LE:AST 6 INCHES. WATERING SHALL 3~ REPEATED AS NECESSARY TO KEEP THE SOD MOIST U~Tll ROCTED INTO T~E SJ3GRADE. SODDED AREAS SHALL Sf PROTECTED AGAINST FOOT TRAFFJC UNTIL -HE SOD IS WEL~ ESTABLISHED 'sE-SODDING: SODDED AREAS WHICH DO NO-s~ow A PROMPT C~TCH OF GRASS WITHIN TEN ( 10) DAYS AFTER J\ISTALLATIO~ SHALL BE ~c-SODDED JNTIL AN ACCEPTABLE STA\10 OF GRASS JS ASSURED WATERING ALL SEECED A~D PLA~TED AREAS SHALL BE KEPT MOIST DURING THE ESTABLJSHMENT PERICO. AREAS CCNTAI\JJNG ICE PLANTS SHALL BE MAINTAINED IN A BARE_Y MOIST CONO:TION TO A DEPTH OF 1 INCH BELOW THE: PLANT~□ ROOT DEPTH. WHEN A PE:RMANENT IRRIGATION SYSTEM IS NOT AVAJ_ABLE, THE CONTRACTOR SHALL PROVIDE WHATEVER T~MPORARY SYSTEM IS NECESSARY T □ PROVIDE ADEQUATE WATERlNG DLRING THE ESTABLISHMENT PERIOD WITHOUT EROSJON DETRJMENTAL TO THE "LANTJNG. 11~RBICIDE APPLICATION P~E-EMERGENCE HERBJCJDE SHALL BE APPLIED ro GROUND COVER AREAS O~LY /\Nb-IN·-~CCORDANCE WITH MAf-UFACTURER' S SPECIFICATIONS DO NOT APPLY IN _AWN AREAS. LANDSCAPE ARCHITECT SHALL BE NOTIFIED AND PRES[~ T AT THE TI ME OF APPL I CAT I ON. HERB l CI DE SHALL BE APPLIED BY AN HERBIC!Df APPLICATCR LICENSED BY THE STATE □• CAL I FORNI A. HEADER INSTALLATION HEADERS SHALL BE 'NSTAI L[J A-THE LOCATIONS AND GRADES SHOWN ON THE PLAN PRIOR TO PLANTING. STAKES SHALL B': LOCATE:□ AT SPLICES, CORNERS AND AT INTERVALS NOT TO EXCEED FlVE (S) FEEl AND DRIVEN 1~1/2" BELOW THE TOP OF THE HEADER. SPLICC: PLATES SHALL BE USED AT BUTT JOINTS. HEADE~S SHA~L BE NAILEJ TO STAKES WITH TWO (2) NAILS, CLI~CHED 1/2 INCH. SPLICE PLATES SHALL BE: CENTERED ON THE JO:NT AND ~AILED TO ~ACH HEAJER WITf' FOUR ( 4) !CD BOX NAILS. CLEAN-UP CLEAN-UP SHALL 3~ MAOE AS EACH PORTION OF WORK PROGRESSES. REFUSE AND EXCESS DI RT St:ALL BE RE:~OVED FROM THE SITE, ALL WA_KS AND ~AVJNG SHALL BE BROO~ED OR WASf--f:D DOWN, AND ANY DAMAGE SUSJAJNED ON THE WORK OF OTHERS SHALL BE REPAIRED TO ORJGINAL CONDITIONS. AT FREOUf:NT lNTERVALS, AND AT ALL TIMES WHEN DIRECTED BY THE OWNER, THE CONTRACTOR Sf-ALL REMOVE AND DISPOSE OF ACCUMULATIONS OF RUBBISH AND DE3RJS OF ALL KINDS. AT THE TlME OF COMPLETION, Tf--E E:NTJRE SlTE SrlALL BE CLEARED OF TOOI ... S, E:QUIFMENT, RUBBISH. FTC. , ALL OF WHICH SHALL BE REMOVED FROM THE SI TE, AND THE ENT I RE PROJECT, INCI_L,DJNG SURROUNDING PREMISES. SHAU. BE LEFT IN PROPER, CLEAN CONDITION READY FOR ACCcPTANCE. ------------·-··----··· ,, ... ··---·---------------- c INAI. OBS[R'✓,'·TJON PRIOR TO A,;cf PT,\~CE Tl1E CONTRACTOR SHALL R~CU~ST A FINAL J~SP~cr1cN 10 B[GIN TliE PI_A~T ESTABLISH'-IEN-PER JO □ A~ TER ALL P_ANT:NG ANIJ Ri-1.AT[D WOl,K HAVc 8rfN CC1s1Pl_~TE:D IN ACCO'l)AN(X WITH HI[ CO~TRACT DOCUMrNIS. A "PUNCH LIST" Wl_L 8r IJfVEL □~~o GY THf OWNfR A~□ LANDSCAPE ARCIJTECT AT THIS TIME. .~NY lTEMS l)l:J_Mf_J NOT ACCEPTA31 c: ilY 1111_ _ANDSCAFE .ARCHJ-ECT OR OWNcR SHALL BE '<rWOl,KED TO T"E COMl'I f I-,;ATISl-,\CTJON OF LANDSCAPE A.RC 11 TECT A~D OWNER. MAINTFNANCE PERIOD (PLANT ESTAFll ISHMt.Nl PU< OD) AFT[R PLANTING JS COMPLEIFll, A FIEI_O NOTIFlCAI ION WII .. L BE ISSJ~O TO THE CONfRACfOR TO ESTABLISH ,Hl tifLCTIV[ BEGJN~lNC DAl-E 0~ THE PLAN-ESTABI ISHM[NT PERIOD. !Hf: Pl A'JT [STABLIS"MENT ,'ERIOD SHALL BE FOR A PE'<lOD OF 30 CALENDAR DAYS ANIJ Sll.~l. .. GE EXTENDED BY TrlE LANDSCAPE ARCHITECT IF THE PLANTE) AREAS ARF lMPROPt.RLY MAJNTAINFD, APPR'::ClABLE FL.~NT Rf Pl AC[M[NT JS REQUIRcD, OR CIHtl< CORR~CTlVE WORK 3ECOM[S ~ECESSARv_ THE CONTRACTOR S~ALL BE RFSPO~SIGLE FOR ADDITIONAi MAIN-[NA~CE OF THE WORK AT NO C-MNGE IN CONT',AC-PRICE UNTIL AU .. Of-lHr WCliK IS COMP_ETED AND ACC~PTABL[. THE CONTRACTOR SHALL CONTINUOJSI_Y MAINTAI~ ALL AREAS lNCLlJDt □ I~ THE CONTRACT DUR I NG THE PRCGR 0 SS OF I Ht WORK, Tl·E MA I NTENANCE PE:RJOD, AND LNTIL FlNAL ACClPTANCE OF THE WORK. AFTER ALL WORK INDJCATE:D 0~ T~E flRAWl~l;S JI, ll[REIN SPECJF'.FD, INCLUDJNG A_L PLANTING AND SF:ECING, HAS BFEN C8MPI f:TEC, JNSPECTEC, A~D A~~ROVED BY TH~ LANDSCAF'f ARCII I TECT 00: HIS Rf PRr Sc NTA -IV[, ThE CJ.\JTRACTOR SHA_L MA I NTA IN Al l.. i'I_AI\ I UJ Af<EAS BY MEANS OF CONTJNJOUS WATERING, Wr.fDING, CUl_-IVAl"INC, SPf<AYl~G, ',IULCHING, TR I MM I NG, EOG I NG, AND/OR ANY o~ERA TI Oi,S Nf-:CESSARY f"OR Tl IE: R CARE AND UPKEEP, FOR A PERIOD OF NO r LLSS Tl AN THIR-Y ( :JO) CALt:NIJAR DAYS, EXCEPT THAT THE: MAINTENA~CE PFRICIJ S·IALL BE EXTcNDED TC lNCLUDE THE TIME NECfSSA~Y -o MEET THE RfQUIRtMENTS FOR COMPLETJON Of'" THE MAJN 7 ENANCE ~ERIOD HEREINAF-:-FR SPECIF JED. ALL PLANTED AREAS S'-IAI__L GE KEPT FREE Or IJ~JRIS, AND SHALL BE CULTIVATED AND WEED~D AT NOT MO~[ -HAN TEN ( 10) DAY INTERVALS. ALL PLA\ITS FOUND ro BE DEAD CR IN AN IMFA[R[D CONDITION SHALL BE REPLACE:) JMMEDIATELY. ANY REQUIRED PRLNJNG Oc PLA~TS WII I BE CESIG'JATED 6Y T~~ LA~DSCAPE ARCHITECT AT -HE ST .'.RT OF THE Pl AN 1 [STAEL I S·1\1EN-:- PER I OD AND -HE CONTRACTOR SHAU_ PERFORM THE ::,RUNING AS ~AF,-:-OF THE PLANT FS-ABLI SIIMENT WORK. THE F]RST MOWING OF COOL SEASON AND MIXED VA~lETY LAWN AREAS SHALL BE PERf ORMED W·IEN THE GRASS IS 2 -1 /2 I \ICHES ~ I CH AND SHAI. I BE: RE:PEATED AS OFTEN AS IS NECESSARY TO MAINTAIN T~E LAWN A-A HEIGf--T oc 2 INCHES. IN NO CAsr· S,IALL THE LAWN BE CLT LOW[R fHAN 1-1/2 INCHES IN HE:IGl·•T. clYBRID BE"RMU 1JA LAWN AREAS SHOULD BE MOWED AS LOW AS POSSIBLE WITHOU-·scAL~ING" OR CAUSING OT~E:R DAMAGE TO -HE LAWN OR I RR I GAT I ON EOU I PMr NI. 1,vBR ID BERMUDA MCW I NG HE: GIIT MAY VARY ANO SHALL BE APPROVED BY fHE LANCSCAPE ARC~lTECT. THE CONTRACTOR SHALL 3E RESPONSJ3_E FOR MAINTAJN:NG ADEQJAT[ PROTECT!□~ OF THE AREAS. DAMAGfS AREAS S~ALL BE REPAIRFJ l M',IED i ATEL Y AT THE CONTRACT::>R' S EXPl:.NS~. WHEN NECESSARY TO PREV~NT PLA~T DAMAGE FROM P~DESTRIA~ TRAff:C DURING TH:'. INI-IAL GROWING STAGE, TH[ CO~TRACTOR SHALL ~R 0 cr TEMPORARY ~ROTECTIVE F[NCJNG TO BE REMOVrO AT THE END OF THE Pl ANT ESTABLlSHME~T PERIOD. ALL PLANTED AREAS S~ALL RECEIVE FE~Tll.ilER APP_JCATICN OF SlX (6) POUNDS PER 1,000 SCLARE FEET OF AMMONIUM PHOSP~ATE TWENTY-EJGHT (28) DAYS FOLLOWING BEGINNING CF MAINTENANCE AND SHALL BE THOROUGHLY WATERED IN. SPECIAL CAR~ SHALL BE TAKEN -o PREVENT WATER S~RAY 0~ WINDOWS, BUILDING WA,_I S. PAVJNG, AND AUICMOl-l!L[S. ALL ~AVED AREAS SHAI._I BE KEPT CONT I NUOUSL Y CLC:AR OF MLD, )EBR: S AND "UDDI .. ES. ~OSES, MAINTENANCE: E:QUJPMEN-AND MAIER:ALS SHALL BE NEATLY STORED WHEN NOT IN USE IN AN AREA AUTHCRJZ~D BY Tt-E OWNFR MAINTENANCE SUPERVISOR 0~ THE JOB S'-IALI_ BE A COMPE-ENT ~NGI, I SH-SPEA<'. l NG SUPERV l SOR, EXP ER I ~NCED IN LANJSCAPE MA I NTENANCE AND CAPABLE OF DISCUSSING MATltRS WJTl1 THE CWNE~ OR LANDSCAPE ARCHITECT ON THE SITE. WORKMEN SHAL_ PRESENT A ~C:A T APPEARANCE AT Al I TI ME:S AND s:~ALL CONDUCT ALL WORK OPERATIONS AND DEALINGS WITH T'-IF PUBLIC IN A DIPLOMATIC A~O COURTEOUS MANNC:R. WORKMEN SHALL BE FULLY Cl □THEO AT ALL TIMES IN DRt.SS SUITABLE FOR F-W ,JOB. AT THE: COMPLETION OF THE I~ THE CON-RACT SHALL BE PcAN-MATERIALS SHALL BF MAlNTfNANCE PER:OD, ALL ARr .. AS INCi lJCJED CLEAN AND f RU. 0" DEBR l S ANJ WEEDS, Al I I __ JV[, HEALT~Y ANIJ FR[[ Of'" :NFEST~.TIONS. 1,,'/> \).IIOSC,4p£ ~,:Y '\-'11\Lff _ -11'~ ~~ 'la~ ~-..,I~,:t;, ~ U .llfflx''c::-Ill .la, V 1'fV --, • -.-1~ lf- ----------- COMl:01 f_ I I ON ACCEPTANCE: UPON COMPLFTION OF Tl,E PLAN-ESTABLISHMENT PERIJJ, AND WI IH!N TEN ( 10) DAYS OF THF CCNIRACIOR' S NOTIFJCATIO~ THAT THE I NSTAI.I. A I I ON IS COMPLETE, :HE OWNE.R AND RFQU I RUJ AGL~C l [S WILL INSPECT THE INSTALLATION, ANC IF FINAL ACCE~TANCE 1~ NOi GIVl::N, W'LL PREPARE A "PUNCH LlSI" WHICII, UPCN COMPI.F-ION RY THE CONIC:ACTOR, WJI_L SIGNIFY FINAL ACCEPTANCF f3Y TH[ OWN[R. THIS FlNAL ACCFPIANCE WILL BE IN WR:TJ~G FROM -Ht CWNER NO ALLOWANCE FOR JEVIATICN FROM THE PLA'lS or, SPECFJCA-IO~S '//JI I BF ALLC'/11:1). AUIH8?1Tv: THE OWNER OR LANDSCAPE AR~HITECT Sfli\LL HAVE THE Fl~AI AUTH6C:i T" 0~ AL_ l TEMS OF THE PROJECT. Wil•y <,;roup L1.l'l!f•e1.p1.. "_'_ e~i1• .. dur• ~ ,,., ;:,•Cly \11 .. "v, /, ' t, ; ,-_,.,,_.,.,,.c;~.,., ,\• ( • .. :,-, ~},l-., \D ~\" f' OF CAL\,tl~--· !:ii'-~l: ',; ,,:: ,,. ; ~ ':'J" '='i(: ., ;•_\·, ·u /, !;:,''' :.i CNCIN[E;R 1S SIGNATURE ~E)UIRlD ON r~AGF.: 1 Ql',;LY APPR:)V[D: APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANT! NG AREAS NAM( TIT Lee "AS --------- INSPE(TOR BUILT" )AT[ [)AT( " "' .... I .. I . ' .... -' ' "" ..... I . I ' DA lE INIT,AL DATF: INITl~L DAIE INITIAL p::v1s10N DESCRIPT ON -_____ _._ __ -+----'-----I ENGINE:::R :)f'" WCWK 0-IIER APPROVAi CITY APPROVAL SHU:.! 5 __c I __ --- ·crrY OF CARLSBAD PLANN f.J::; DEPARTME~T -, SH!:ETS 12 TAYLOR MADE GOLF DW~ 8Y: _ ...... . CSKD Br, RVWD BY· . _ . CARLSBAD RESEARCH CENTER CARLSBAD, CALIFORNIA . .,,. i PROJ[CT NC. HDP?_i_:lf DRAWIN::; ,o : 3~1-~ If- () 0 !O 20 30 FINISH--, GRADE VARIES .. -[ -:12" "' -. ..,_ .--CONTROLLER . ~ ... .-STEEL ENCLOSURE-0 AINT PER OHNER-.. _/~ \ ;··r;:.-, ' ~ ..... ,~-3/4" EXTERIO'<. GRADE AEF'L ,HOOD BACKBOARD PAINT HITH 2 COATS EXTERIOR ENAMEL LOCATE 3" CLEAR INS'::>E OF STEE~ ENCLOSURE 15ACK FANE-. -----l-l/2"xl-lt2"Xl/4" GALV. STEEL ANGLE s-lFFENER,:,, SECURE 6ACKBOAR!il'll-H CADMIUM PLATED 3116" S,CVE 30L TS 16 MIN J -----DUPLEX RECEPT ACLEt,ROUND FAULT) ·--SECURE ENCLOSURE HITH 3/8"x&"xl" ANCHOR BOLTS r6 M,N ! " ,.-MOH STRIP IN LAHN AREA;', ~~/!, _ 2" (MIN J PVC SCH 40 CONDUIT FOR CONTROLLER HIRES TO F.B. 1 -111 r. •;::.,-1_--i11_1111 USE '30 DEGREE SHEEP ELLS ii I I 11 I~ §l : , ;. • " 1-_1 11= .:111 111-"'_.,.,.,,,...,.H"ttm=M(·-Tn=-IO" HIDE CONCRETE ~DOTING 1 __ 111 ,,_I I Ir I' -b''~::;--~--3;4• F'VC SCH 40 CONDUIT COMTROLLER E!ll!CLOSURE il!OT TO 8C.IILE NOTEe, I, INS-ALL l5N BULB IN PLJG-IN LIGHT SOCf<E-:- 2. VERIFY LOCATION HITH CHNE'<. PRIOR TO INSTALLATION 3. PROVIDE POHER AS REQUIRED f-~ -r L w E w <J) '1 w w z _J w (}' IL ------- Proposed 3u1\d1n9 i! -~ CRITICAL ..lEAD DEMAND 2" RCV .44 " ELEVATION 144 CRITICAL HE.AD .AT ELEV..:lT'ON 3"),le, G=M FRICTION LOSS, LATERAL LINE 2' REMOTE CONTROL VALVE 3" c_ 31,:, 0 vC IE,30 LF '2 J 2" EIA~L VALVES 2" PRES5U"'-E REGULATOR 2" R P BACKFL 0-" METER ! ASSUME 2 '! ELEV. 173 ELEVATION 2"J' FALL HE.AD ::>E'1..:lND TOT AL DEM.:IND PUTURE R.C STATIC ""!;,I ( H,G,L,3E,4J RESIDJAL p;;1 POP-UP HEADS, 0335 0 2 03.48 03,0 >NIA 085 o· '3 ff 2 :?6 30.00 3"J.51 "JI, 31<> ,:, I, "J"J .A,-6 ···vALvE STATION 1 GPM -:-HRCUGH VAL VE lj! 1~ /;VALVE SIZ:': _________ ,... : '\:,. NOTE, 'NST ALL 12" POP-UPS IN GROUND COVER AREAS AND 4" POP-UP;', IN LAHN AREAS. /NO-E, A_L ..lEADS SHOHN ARE "'OP-UPSJ ! ·-;~ "' ~ o·o•,,.•-•,_:;:,~, -•~, 0 },._; ~ .. ·~·'"··--···~·-··';··-· L .... .. $iC>E0J:ZL K r---,; ~-~ I I 30' LANDSCAPE EASEMENT / ·•--.. TO BE MA NTAINED BY _______,,// CHECK VALVES, INSTALL ..lEADS HI-H FACTOR~ INSTALc.ED CHECK VALVES IN ALL LOH ::>RAINING HEAD;', SLEEVES, UNDER VEHICLE PAVING USE SCH W SLEEVE HITH 30" COVER FOR MAINS. HIRE5 4 LATERALS. UNDER PEDESTr<'IAN "'AVING USE SCH 40 5LEEVE HITH 18" COVER FOR HAINS. HIRES. UNDE's PEDESTRIAN PAVING USE 50-1 40 SLEEVE HITH 12" COVER FOR LATER4LS. , ·• JJ~~rnw · r ll.111 ····-··' r )-)~~i~ ~J~-)t~~~ II ~.oo· . r ll~[ ~.-.,.~- (EXIST, 2' Rev A'3-- POT ABLE s-.STEM TO REMAIN IN PLACE) !'""ASTER DEv::::LOPER (EXIST. 2" RCV AB--// REPLACE NITf--4 NEN ~~· PO-,-ABLE SYST::M) SHEET;; 6 4 "J e COLLEGo: NORTH NOT TO SCALE / -✓ ~' / KE'r MAP { Wil•y Qroup L1u11d,eap, Archlt•ctur• !<.;,;-, F-c,v \'\'1l"1y, A·,.(, A I c.n,h,·_c,pe-L:..·ch;\,,-cl ~f~n N-:,o1,:, ~J ··,:, :w-rni ,·,,-n r1,,...,1n,, ~-'~'..<:'l'.l i· 19 /~-'-) ·:--;i•,:i;• f"ll. 1-:· # l."5'~ ENGIN,,R'S SIGNATURE REOUIRED ON PAGE I CNLY APPROVED: ENGINEERING PLA>.j CH(CK(R DATE: J{t() DATE INITIAL REVISION DESCRIPTION ENGINEER OF WORK iRRIGATION ECUf 0 M NT T ABL_ QT"r DESCRIPTION C•ETAIL .. ---------------2517 -11' 200 "'SI SDR 2' PVC c:o1PE 'ALERTLINE' LATERA_ LINE 5112 11:'>C,-1-!4' SCH 4C PVC P'0 E 'ALERTLIN=' MAINLINE 5/12 2CJ' -1-!!2' 200 PSI SDR 21 PVC P!PE 'ALERTLINE' LATERAL LINE 6/12 f--1~1~cct--_+-[ -~.-,4~·~:-o~-o-p=-c,~" i~S~..J-R~.~-, I-P~v~c-p-rp~E-4-LE-"'!~T-L-IN_E_' -L-A~T_E_R_A_L_L_N_E----1 6/12 1363:'.: -l/2" 315 P$1 SDR 13 S .PVC ~IPE 'ALERTl. .. lNE' L,-2.TE~AL LINE -~---·-· 8/12 f-----+---+-----------------------. ···-----, S70 e OLSON 12 OU, L=T E"11 TER EH-12 1704 J,R.SQ/:2 12 ,. RAINBIRD 1804-'lF-FL T ---3C_·_P_S __ 8_'_R_A_D-.-----~H/12 B0 v RAINBIRD 1804-8H-FL T 30 PS 8' RAD. H;l2 42 v RAINBIRD 1804-8Q-FL T 30 PS 8' RAD. H112 12 v RAINBIRD 1804-'lT-FL T 30 PS 8' RAD. H;l2 4 ,. RAINBIRD 1812-8F-=LT 30 PSI O' RAD. ----,H/12 r--e,=7ct--,,-+=Rc-A,--l,--N=B~IR=D~l-:8~l2~--8-H--=FL=-"-30 PSI O' RAD. ·!H/12 34 v RAINBIRD 1812-8Q-FLT 30 PSI 'O' RAD. JH/12 f-----t---+-------------------------~ 13 v RAINBIRD 1812-8T-FLT 30 PS: iO' RAD. H/12 3 rn RAINBIRD 1800 SERIES:T·~,;,=E~S~T-~3-0-P~S-.-4-'X-1~$-R_A_D ______ H;l2 e, ■ RAINBIRD 1800 SERIES-lc,F·-~3~0~P,..S~..,.1$~.-R~A-D-.-----~H;l2 ,,,,~~=-===------.• ,,,.,_='") -, RAINBIRD 1800 SERIES-'5H 30 PS I$' RAD. ,H/12 ' "" e>I l"l RAINEIIRD 1800 SERIES-SQ 30 PS, I$' RAD. H112 --c+--+=--==========~~=-====-----~ 33 B RAINEIIRD 1800 SERIES-,:,SST 30 PS, 4'XI$' RAD H112 II e, RAINBIRD l'lOO SERIES-ST 30 PS: 1$' RA::>. H/12 r---=-+---+====-=-=cC'""'C==~==-=======------,, $ " RAINBIRD l'lOO SERIES-STQ 30 FSI IS' RAD. H112 6 " RAINBIRD 1800 SERIES-5TT 30 PSI IS' RA::>. H112 "J5 -2" 200 PSI SDR 21 PVC:: FIPE 'ALERTLINE' LATERAL _INE El/12 6!1-,2" 31,:, PSI SDR 135 PVC FIPE 'ALERTL NE' MAiNLINE El/12 ' 46'cl6-,3" 315 PSI SDR 13 S PVC PIPE 'ALERTLINE' MAIN_INE 6:12 -""3"'4"'18c-,-_=3-,-;4-;-;,,c-:~,o=-o-:::, -cp=s,--1 ""s=c=R~2~1 =p-:-v=c=p~IF=E=,-::.,.~L=E=R=T-:-L-:-IN~E='~L-A-;-;-=E=RA=-L-:-L=N=E----1 El/12 16 -,Nibco T-c,80 Sall valve 3" <L'ne Size' D/12 ---------------------1 i 1 ..... Nibco t-580 Bill' v~ ve 4•·, 2" 4 l"~-(1) E.6.C!-l (line Size) D/12 :----.t---+=---==--cc--cac-----=~--------------1 2 r-J Febco 2" Backflow Preventor -e,25~ K/12 r-----t---t-------------~-------------K/1,2 r--=3.!1 "'@-t;-~"'e"'1,-o-n"'"1=0"'4'°,;-Q=-u"'1 c"'k-:,,C-o_u_p'le----:-vcca,l,-1e-1'"' cc/N'OccN~-PccO=T-cAccBccL-c=cc)-------1 E/12 36 @ Hume, PGH-ARV-6 40' R..:lD " $0 PSI 12" POP-UP H/12 r-,,,-~_-_+-03-+ccH-un-,-,.-,"'P=-G=-M--"'12--A-,---R,,,-,.~2-0=· -,N,c=-z=-.-2=1~,-R=-A'D=-. -.,-40~P=S'i -,12~. ,-, P~O-P---u-p---lH/12 ·, $ Huncec PGM-12-A-R" 10 NCZ. 2' RAD <> 40 PSI 12" POP-UP H/12 "J G RAIN31RD PESEI RC valve I" /USE 314' FOR DRIP.' ----1=;:2 -------ll 7' TO NEX'f VALVt: .,-. "··- REV:EWED BY: I • ", ,--{ APPROVED FOR PLANT I NG AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS L.:3/~--- INSPECTOR OF CARLSBAD PLAtmlNG DEPARTMENT t-w w 1, J r-~ -__,__ ~~ --......:-:: 1·2·18 DAT( 1s~~ETS I I _____ I I SH~ET 11 ~lTY TAYLOR MADE GOLF DATE DATE OTHER APPROVAL CITY APPROVAL CARLSBAD RESEARCH CENTER CARLSBAD, CALIFORNIA ASSISTANT ~LANNING DIRECTOR DATE C,M.W.D. JOB NO. :16-244 -~~~------- ·------ LOT 7B _; I] :o #%20S ' PL01 J:a10 i ---.........._~---··---.. ... __ ! -----------"-•'-•, ...... ._ ____ .....,J 1 ~ MAIN LI(\//;:$ ,l _I ---. QC I .. --··· .;~ ,, '--··--·-"· ., '~----..... :·, .. ··-·---~ _,,...:,.:.,.,.~·:;:·'.:::" ... , ;: . . ··-,, ,. ',') ~~-j~~~~ ] f fl I.Ji ~~-i~~~ r l1.11 , ....... ,. ' ' ,~ .-~ .. , .. ,"''' s ' · :•~:1<'.,:~\J4,~-~:'.;i~{½1J?:· , :1 ,. MAIN tVAL-VB 14' FOG • ' MATCH LINE SEE SHE:"T 6 ' \ Fl'sOF05 eu:c..oNc, e COLLEGE NORT+-4 NOT TO SCALE PROPOSED TA '(LOR COJR ... S':Jmbol ,,-·-,,, '...._,.) • .:.i;::::ei-t ,,-,,, i ._._,. ·•-•,, . ' '. i • .J _,. '','I,··\ ,: '." '"lif" ., ., ,_ \, ; ·wr . , .· ........ ' . _.,~ r .. ,. '-J ··-. ···' •''" ,f, :, .. '.: " PROP(JSED EMITTER DTSTR.-BJTION-,. CH.ART "'" ' 10 T'Jrir )0-, I r j),~ L --· ···-~ 15"'ELL @CORNER Sci enti f' c Nacne Cocnrron Nar,,e ' Size Outlets Per Plant, I GPH Each Deep Watering Tt..,bes -.,. ·r· . Er'.;jthr 'na Ga f:f".• a SJke<Sil-m, Co·al T0 ee 24"-Box 2 £) Lawn, B £) Shrub Arsa .. --Agaparthus a fri canus 'Queen Ann' Bue I I I ':I of Nile I-Gal I ~·~· Carie-sa granoiflora 'Green Carpet' Prostrate natal plurr -Gal I ~"' -,~. ... , L, 9u, dambar & 'Palo Alto' American swsetgum -'"\.," -3ox ~ -Ill Lawn. s £) Shrub Area ,-• Moraea (Dietes Bicolo•! Butter rl::J iris -Gal I . proenl x dact':11 i fer a Date pa "!I 15 ,, £) Lawn. B £) Shrub Area t --,., .,,. Phoenix roebelenii P, '=i"'':i date palm 15-Gal 4 -----Phormium tenax 'B•onze Bab:,1 ' New Zealand fax. 5-Gal 2 .. .•. Pit tosporum tobira Japare5e mock orarge 5-Gal ' • ,., "' ,. Pi ttosporum tobira 'Hheelers dwarf' Wheelers de,arF tobira 5-Gal I ... . ... , Podocarpus Gracilior Fer--1 Pine 15-Gal ' £) Lawn. 0 -Ill Shruo Area • . , .. , Raphio:epis irdica lndi an hawthorn S-Gal ., ... .,, Tipuanu T1pu T1pu T"ee 15-Gal 2 -@ Lawn. 0 "1l Shruo Area . -~---·-· ,, -,puanu Tipu T1pu T•ee 24' -Box L £) Lawn, 8 £) Shrub Area . --,,. ··- Lonicera j 'I-la Iii ana' 1-lall's Hone::JSUCkle Cut tines I where shown 'n drip area ---- NOTE, INSTALL I EMITTER BODY PER -REE OR PALM TREE AS Sl-lOHN. f,l·)/':,9?, 252? 1. ,l LIi. If ~~,C1 ENGJN£ER's SIGNATU"\E PEQUIR~D C}N PAGE 1 ONLY APPROVEJ, ENGINEER NC F'LP.N CIIEO'.ER DAT[ APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS 2 £) Lawn - ' -Ill Lawn • -- ' £) Lawn "' ' .. ,, 2 -@ Lawn ,m~ .• 2 £) Lawn ~ " £) Lawn (use 1/2 GPl-l Emitter) REVIEWED B"i: L~ INSPECTOR f--w w I <J) w w <J) w z --l I \j f--<l I: ~ 4" SL // CONT I -!--~---~~- . t·~ i'. ' .. ·;:-,. ,, \__, ,'·-- ' . ..: l' L/-5" ELL t' FROM WALK TAYLOR MADE GOLF DATE INITIAL DATE INITIAL DATE INITIAL REVISION DESCRIPTION ENGINEER OF WORK OTHER APPROVAL CITY APPROVAL APPROVED· DWN BY; __ _ CH,D BY: .. R'IWD BY: CARLSBAD RESEARCH CENTER CARLSBAD, CALIFORNIA 4J) C.M.W.O. JOB NO. _'=i=b~-~2~44 _____ _ w () UJ _J _J G u / j,,_ ff~'<l2D5 • PLOT 1■",0 i 1 I ' -. • ~·•. _,·.i .. • i ' i ' \ ! . ,',I,.,. ' ; ' I) l I) 21J 30 Qc BUILDING 5f.lEETS 6 4 ':I e COL~E'-"E NORTf.l NOT TO SCALE KEY HAP HATC!-< LINE SEE SHEET 1 (:, 1 '1 /"•9 ~-;,~,;:,;·· 1.:A ! I·~· # lfl~<~ ENGINEER'S SIGNAT~R[ REQJIRED ON PAGE 7 ONLY APPROVED, ENGINEERING p:_AN CHECKER DATE -·· --···-··--·--+----+------ 0----_,, -~-------I---------- DATE , NITIAL REVISION DESCRIPTION ENGINEER OF WORK -<_.;.~ ; ~It. L.•·. :·1· : .. ••· .§itR"lB¾' ~-:_ ' : •a' ··c-- APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS -------~-• ·--~'','. ''· ' "AS BUILT" f1M h/4.&Y{o/ M) 8-u•tB NAME L ~ . _;;, CATE TITLE, · "J_. REvlEWEO BY: L.J¾-ck...,, 1-J·ffj INSf"[CTDR DATE ------------.------t------t-----1 TAYLOR MADE GOLF CARLSBAD RESEARCH CENTER CARLSBAD, CALIFORNIA .. ····-· +---+------1 ~:=::=.:=:v=A:=:=P:-LA:-N:-N=:~:;,G.=--<~~c;:.,R=EC=T:;;:o,,_R===========_-_=_-.=: /=_-/.=.-~=f=_-E_=_-'(= __ = .. -'.?=.-_-_ .. ~I :=======:-;:=======~ DRAWING NO DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL DWN SY, PROJECT NO. ~~:~ 8 ::_:8~::_:'.-::;,~~~~~~-H_D_F_~_b_-1_4 __ ~ __ ~_-?_2_-_3_L~ C.M. W .0. JOB NO. -~~~b_-~2~4_4'------- 0 (\) r I- Q _J 20 30 SOIL AMENDMENT&, TURF AND GROUND COVER, '-•• • ~•••c • •• .•• .., ,,(! ' ' ~-'' _'.s {kffl~ ,, ... ,,, ~-~~--~--~-----APPLY THE FO_LOHING TO EACH 000 SQUARE FEET OF SO L, I. 75' FOJNDS OF AGRICJL TJRAL GYPSUM 2. 4 CUBIC YARDS OF COMPOSTED ORGANIC PRODUCT TILL IN TO A DEPTH OF 6 TO 8 INCHES AND IRRIGATE Ti--lOROUGHL Y AFTER APPLICATION. HITH 4 TO 6 11'CHES OF HATER USING INTERl'11TTENT PONDING. AFTER LEACl--llNG, APPLY .,.HE FOL LOH ING TO EAC...j 1000 SQUARE FEET OF SOIL, I. 20 POUNDS 15-15-15 TILL It's TO A DEPTl-l OF 6 TO 8 INCHES AND IRRIGATE THOROUGHL -r· AFTER APPLICATION. H!TH 2 TO 4 INCHES OF HATER USING l1'TERMITTENT PONDING. BACKFILL FOR 51-lRUBS AND T~ES, ADD THE FOLLOHiN~G~.,.~0-E~A~C~l-+~C=U~B~C-Y_A_RD __ O_F_B_A_C_K_F_IL-L CONSiSTl_l's_G_O_F_0_ PARTS NATIVE SOIL AND 4 PARTS H::LL COMPOSTED ORGANIC "'IATERIAL. I. 15 POUNDS GRO POHER FLUS OR THE EQUIVALENT '.: 3 POUNDS AGRICULTURAL GYPSUM. MIX THOROUGI-IL Y BEFORE BACKFILLING -HE HOLES. SOILS TESTING, -...,E ABOVE SPEC,FIEP "SOIL AMENDMENTS" ARE THE MINIMUM ACCEPT ABLE FOR .,.HIS PROJECT TAKE A MINIMUM OF 2 RECORDED SOILS SAMPLES FROM SITE AFTER T'-1E COMPLETION OF ROUGH GRAPING AND SUBMIT FOR ANALYSIS TO AGRI SERVICE PH, (61'3) 727-5451. LESSER AMOUNTS OR PROCEDURES HILL NOT BE ACCEPTABLE. SEE LANDSCAPE SPEIFICATICNS SHEET L~4 -···-·········---. f ~ z w r-w <fl ,:r w w z .__J W' O'. ll. / ·t·:·,"-..,,,_J_~ .. -··-"•,., ___ _ ' ' HATCH LINE $EE SHEET '0 Proposed TREE RATIO, ON SITE TREES PROVIDED 17B PARKING PROVIDED, 012 RATIO, I -REE / 3.44 SPACES r ' ---f ' 30' LANDSCA0 E EASE,.-,ENT~~ TO BE MA.INT AINED BY MASTER DEVELOPER _1'.J ___ ..i.. •• .t:o> ~ E\UILDINC:r e COLLEGE NORT"4 NOT TO ecALE '<fl 1-w w I <fl I '/··' --'' ,/ 0 . + I \ / PLANT L ST Acacia redoler:, Aga pant,;us a fr i ca'1us 'Queen Anr' Ainu:, rhombi fo i a Alnus rhombifo ia Calendula officinalis Ca-issa m. 'Green Carpst' Common \Jame Code Name Acacia Acre Blue Ii I':;/ of "-ii le H,;i te a Ider Alrh Hhi te alder Alrh Ca lerdula Caof Cagrp Size Spacine/Detail I-Gal I-Gal 24 11 -Box. ex isling 4" Pot I-Gal L, P/12 2' O.C. L. P/12 L,M,"-l,J/12 8 " 0 ,--~- L/12. SO.SP L. P:12 Quanlit'::j 183 757 51 N;A l'320 764 r--------+---------------------+--------~---~---·---·---+--------+------+-------+--- Eau 5-Gal L/12 [':)4 1-) Elasagnus p.mgene, ".'horn::J elaeagrue, 1------,,,.:.,,.-----+--------+=,L_-~_,,, ___ , -~=-----+-------------t--------+----~---,------+- Er'::jthrina Carfra Coral Trse Li9uidambar s. 'Palo Alto' Ae1sr i can swee:gurr Lonicera Japorica 'l--lalliana --la 11 's hone':;/suck.le Mora ea. Di ete& bi color Ercf ;_iSt Mora 24"-Box 24"-Box Flats I-Gal L,NO,J/12 L,N,OJ/12 B O.C. P/12 L. P!l2 Phoenix dact'::jlifera ::>ate palm 0 rda ·5· B-,-1-1 L,"-/,C,J/12 34 10 320':l 15'31 22 r---~----+---------------------+-------·-----·----t---------+------+------+- C • !'"-; . ' () I, 0 \ ---) Phoeni x roebslenii, triple Pi9m:3 date oalm Prro 5-Gal L,J/12 0 Phormium tenax 'Bronze Bab':;/' Neu., Zeala,id flax Phte 5-Gal L/12 31 Pittosoorum tobira ' Pittosporum tobira 'Hhselers dwarf' Fodocarpu5 Grae· Ii or Raphiolspis ind ca 'Pink. Lad•::J' T1puanu Tipu T1puanu Tipu --""·--··-·······-Lo j a Flats 0±07 ' ( L6ja __ ,, __ Flats 3643 w;1.,. Giroup L"1dn"p• AreflH:•etuH Japa'1ese mock. orange Pito hheelers dwarf tobira FitoH Fern Pire PociGr lroian hawthorn Rain Tipu Tree Tiptp Tipu Tree Tiptp -~-~~"""'" Star Jasmine Tr j a 5-Gal 5-Gal 15-Ga! 5-Gal 24"-Bcx 15-Ga: I-Gal L/12 L/12 L M,N,J!l2 L. P/12 L,NO,J/12 2' O.C L P/12 208 382 101 201 20 18 430 -----., .......... . "AS BUILT" t-w w 'I <.fl w w <fl w z _j f:im Roy Wiley "'SI A I nf,d,'l,."<)(,',' ;l.1d·i\';',_ '· 111;::,J New_,,_, l<c: ',Ir '0~ IC·) ,,/Jr\ [,i,q~•-,:ti. ,;,2119 t-> l '·.'•I._,,_, _.,_ 2 ';,2 2 i'A ll(' II lW,q APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS --------------NAME DATE ENGINEER'S SIGNATURE REQUIRED ON PAGE 1 ONLY APPROVED: ENGINE:ERINC PLAN CH[CK(R DATE ---·c,·• ••••--1r----t--------- I----+ -··-·-········-"··+------------- DATE INITIAL TITLE, REVIEWED BY'. INSPECTOR DATE ----+----l---<---+-----11 SH!ETJ I CITY OF CARLSBAD I SHIE2ETS -_ ?LANNING DEPAR-:-MENT . -~~==========='-'====='. -------------+-----1-----1---+-----I DATE INITIAL DATE INITIAL TAYLOR MADE GOLF CARLSBAD RESEARCH CENTER CARLSBAD, CALIFORNIA APPROVED:~4-P.. ..... , .,, _____ //-£-92 ASSISTANT P'.,ANNING OIRF.:CTOR DATE OWN 6Y: REVISION DESCRIPTION CHKO SY: ___ _ RVWO SY: PROJECT NO. f-lDF'30 -14 DRAWING .. NO. 352-3L ENGINEER OF WORK OTHER APPROVAL CITY APPROVAL C.M_W_D_ JOB NO. ~'3=0~-2~4~4-'------~ .. ..,.--............... LOT 78 I) lO 20 30 Loja Flats 3505 / I / \ ' ' loja Flats 8:',3 ,._,~·"\._, __ ·---, ·{', _____.____L__ __ ______;,;;;;;;.,__-~,,-------,,----------------1P~R"+-0-,,4>P-'-'0~Sf-FE+-D+-+T-+A',-----'1Yi=-+L----1-0"------+!,,,-RL-Cr---+-O--l+-LJ+l,,,R-'--T1-------------"-'··-----,---- ,., .... ,, ' ····-,.-~~,,; .,. """'-J. ·. ~ !,_,,...;r"------·-··-, .. ..............__...,_,_.,_,, -·- ·, .·~,..,..,....,A••cJ ,'-,' .1,••••·-· .. •••:--n .... ···•-••- J-r?-ilf---.. (~' • N ,:---·-..... -·-~- _/'\) I ( 1-z UJ r: w ,J) "'1 l1J l1J z _J IL ( I / -···-·--- LoJ a ~lats 2047 •"' ----✓~~~~•~•,.w••~ ,...,, -"" ' _./ PROPOSED MATCl--1 LINE SEE SHEET ':l &,··.~~:.Tw'·~f ✓ ,/ ii / ii e NORTµ NOT TQ SCALE I' BUILDING SHEETS 6 • ~ COLLEGE 25' X 2'::>' DRlvEHAY ~ S•GHTLINES (T"TF) •, - -----------··-.... ....... ~ ............ '-., ... ,:-:.c.••·······-~- ' \ TURF .',.:------:; i"'i·'~-,::::· • • ·.·./&. "'· ,,,,,. ------··-'-· T' -,r--•.c"••·• .,•" • .~· ,.·:>•"•:: . ..,..... . ' . ... ·,i,:;.·:~ ... '····~-:,~~,,--.--··· ;i -r~ -; ~ 1 I-i'":tal 283 .. , ...... ...,. .... ,; ... MULCH: NOTE INSTALL A 3" HINIMU"1 LAYER OF 'HALK ON BARK' OR APPROVE:) EQUAL, 1:--, ALL GROUND COVER AND S:..JRUB =LANTING AREAS HITJ..I A SLOPE LESS THAN 3 , I. (TYPICAL! SLBMIT SAMPLE TO CIT'!" INSPECTOR t LANDSCAPE ARCJ..IITECT FOR A°FROVA_ p:;;;;:IQR TO :)ELIV::RY TO Sl""E. ROOT BARRIER, ------------- :--,ST ALL ROOT B4RRIERS =oR ALL N. S-E:ET 12. < T'-FICAL) TREES NIT,-4IN 10 OF IMPROVEMENTS. SEE DETAIL t- llJ w :r cJ) w ' ~ .. :t__ OJ "' (J"G <{_~\'1 BUILDING TURF, 1-iYDROSEED H--lE FOLLOHING PER ACRE & l1J z _J I I I ' CYNON::::>ON DACTYLON VAR. 'MIRAGE' HY5RID BERMUDA -s COVER Cl'i<OP: -·····-·""·· .. HY::OROSEED THE FCLLCHING PER ACRE LOBULARIA MARITl!'"""A 'CAR=ET OF SNOAI' " 6 LBS. HYDROSEED MATERIALS, hOOD FIBER "' 2000 LBS. FERT 1 LIZER (I0-2C-0! SJ 300 LBS. AZTAC 5I1'sDER (Oc;;: EQUAL) SJ 140 PLANTNG AREA RATIOS, LBS. '00 LBS .l u t--1" r: ZONE I -T:.JRF"' BUI_DING 10.177 S.F. (B"'-~~)_TURF"' PARKNAY 11.122 S.F. <B.6~s) ZONE 2-REFINc:C LANCSCAPE-10.202 S.F. (5':l'"'I ZONE 3-NATURALIZING LANDSC::APE-30,354 S.F. (24S'o) ·i\,/.:1') ~,.:ns• i!d ··.I,· Ii.I~' 11)) '", •r; ['I•'~•·•. ( /::. ·.:,~·I I ,:1 t, I I/'"°) .'i · ~".i:?:' (f\ _II ,I :1:1~-'3 "AS BUILT" NAM( DATE TITLE: __ _ ENGINEER'S SIGNATURE REQUIRED ON PAGC 1 ONLY A=-PROVE): APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS REVIEWED BY: ENGINEE'.RING ~LAN CH[CK::R DATE IN5PECTOR DATE CITY OF CARLSBAD . ·: I SHl;,ETS PLANNlt~G OfPARTt...1~'-.IY -· .11 ,:;.. TAYLOR MADE GOLF APFROVED: CARLSBAD RESEARCH CENTER CARLSBAD. CALIFORNIA -/-:ft}/ I /~t,~_7 t----,t---➔------------------,t---➔---+---+----, ~cAJs=s=-~1::-S=T=-.::A,--~N:::-;rpJ;;[=Dl'R:E";:c"::::T:O~R;~~~~-~;===,;;;;;;-::;-;:D=:A:::T:=E=::::::;:=::~ DWN BY, ____ PROJECT NO ··-~ DRAWING NO. DATE INITIAL REVISION DESCRIPTION DATE INITIA_ DATE CHKO BY:----HDP~b 14 LR:..:.Y_::W_:_D _:B:..:_Y.:..:' ====-~------_ ----3 '::> 2 -3L INITIAL ENGINEER OF WDRK OTHER APPROVAL CITY APPROVAL C.M.W.O. JOB NO, '30-244 .~~~~------- I I ' ! ' \ 0 Q:; i~ ' :>: · 1wi/ __j ! \ '; ::J' \ ,() s a) :\ ' l\ ··:-;·~~---~--; ---·--. r·) ,..1 ~--I I ' ' I ' ' MATCH _ INE SEE SHEET '3 ' I ! ~ , EXISTING ALDER TO BE R::MOvE:D , AS REQUIRE;:) IN GRADING AREA r• " i ' .~\. 0\ 7\\ ;;< \\ -----,; ) \,' ~~U-1 ,\,' 33!:,!:, . ~--- """.;..o.;;:,r;:,\'' . \,\r---. __ ,~~-:;r:'J;x , ~-·-~----- -.....,._ ___ ~-7 ··-•-.-_ ______ , ____ ~--1 ' ~-.I ' ' i f &, "' ' I ' ' . . ' @; ' ' I . I f I ' i ! ·-.. .. ~ --,'ID-~! 0 ' ' i ' : _ ___];\, OTHERS <T1FICAL! --~ ... ~----~------------, I ' I - 20 ' I 30 ' i I I I ' ' ·-------... ___ ... __ ......, ___ _ ' ! I / i ------------~----- I i CITY OF CARLSBAD 5LQFE FLANTINC. STANDARDS AREAS OF AFFc.lCATION (PLANTING! ;,LOFES--b, I OR STEEFER AND A3 FEET OR LES;, IN VERTICAL HEIGHT AND ARE ADJACENT TO FUBLIC HALKS OR STREETS REQUIRE AT MINIMUM STANDARD "I <COVER CROF AND JUTED!. e. 4 FEET TO 8 FEET IN VERTICAL HEIGHT REQUIRE STANDARDS "I, "2 AND ":;,, C. IN EXCESS OF 8 FEET IN VERTICAL 1-lEIGHT REQUIRE STANDARDS "1, '2.-:; AND •4. SPECIAL CONDITION;, AREAS GRADED FLATTER THAN 6,1 REQUIRE STANDARD "I /COVER CROF! WHEN THEY HAVE ONE 01'< MOl'<E OF THE FOLLOWING CONDITIONS, A SHEET c:;.RADED PADS NOT SCHEDULED FOR IMFROvEMENTS WITHIN b MONTHS OF COMFLETION OF ROUGH GRADING B, A FOTENTIAL El'<OSION Ff'<0!5LEM AS DETERMINED BY THE CITY. C. IDENTIFIED 81 THE CITT AS HIGHL T VISIBLE AFi<EAS TO Tl-lE FU!5LIC OR HAVE SPECIAL CONDITIONS THAT WARRANT IMMEDIATE TREATMENT ~<il",i2D':> P\.OT 1-10 I ' I ! ! i I ' ' ' i I i ' ' I I ' ! ' ! ' ' i j ' I CITY OF CARLSBAD SLOFE FL ANTING ST ANDARD5 ST AND ARD "I -COVER CROP/JUTE MESI-I j / ! i ! ' ' ' ' I i COVER CROP SHALL BE A SEED MIX TTPICALL T MADE OF QUICK GERMINATING AND FAST COvERING GRASSES, CLOvERS, AND/01'< H!_D FLONERS, SUBMIT THE S'"'ECIFIC SEED MIX FOR CITT APPROVAL '"'f'<IOR TO AFFLICATI~. THE COVER CROF SHALL BE APPLIED AT A RATE A MANNER SUFFICIENT TO Ff'<OVIDE <a0"'o COVERAGE J,,,iTHIN 1 30! DAYS TTPE OF JJTE MESH SHALL BE AS AFFl'<OVED 61 THE CITT AND STAKED TO THE SLOFES AS RECOMMENDED 61 THE MANUFACTURE I'<. JUTE MESH SHALL BE REQUIRED HHEN FLANTING OCCURS BETHEEN AUGUST IS AND APRIL IS DURING THE "<!cMAINDER OF Tl,JE TEAR, THE COVER Cf'<OF AND/OR JUTE MESl-l MAT BE USED. ST ANDARQ "2 • GROUND COVER ONE HUNDRED !IOO<'o! FEl'<CENT OF THE AREA SHALL BE FLANTED HITH A GROUND COVER KN0>"1N TO HAVE EXCELLENT SOIL BINDING CHARACTERISTICS /PLANTED FROM A MINIMUM SIZE OF FLATTED MATERIAL AtsD SFACED TO Fl'<OVIDE FULL COVERAGE HITHIN ONE YEAR!. STANDARD • 3 • LOH SHRUBS LOH SFl'<EADING HOODT Si,jf'<UE,S /PLANTED FROM A MINIMUM OF 2-3/4 INCH LINERS! SHALL COVER A MINIMUM OF SEVENTY 11@.! PERCENT OF THE SLOFE FACE / AT MATURE SIZE!. STANDAF?P •4 • TREES ANDIOR LARGE SH"i:U§S TREES AND/OR _AR<:;E SHRUBS SHALL BE FLANTED FROM A MINIMUM RATE OF ONE <I! FLANT PER THO HUNDRED /200! SQUAl'<E FEET. i ' ' I I I ;\:_A.,• \1 + 0¾\ \ i i ' Loja FLats 10223 ! ' PROPOSED BUIL::>ING } I I I e NORTH NOT TO SCALE ZONE 2 30.440 SF COLLEGE . -, .. , __ _ PR~fO D /NGE ~- <EY MAF MATCH LINE SEE SHEET 10 --.................. __ ZONE I 8.'300 SF TURF 0 TURF Aqaf I-Gal 3 ";, Aqa I-Gal 02 TURF ':>,263 " i! ·•+ .... ¥ WIiey G,o,..p L111"IIIIH4t.p• Arc,hlffll:!'1.lr• w K,m P:,y Wlej, .-1.S.L.A L.::mdsccpe Ar·(l'i\':'C'. ~6$(,: M"~*' R~ Sle 102-10) <:,,:,, D'.;,;o. C,c.. 92119 t;J'.l/')95-2':>22 CA LI( // 185',1 APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS NAME TITLE: "AS BUILT" DATE ENGINEER'S SIGNATURE REQUIRED ON PAG[ 1 ONLY APPROVED, -"GINEERING PLAN CHECKcR DATE ~ L___!!_J REVIEWED BY: INSPECTOR DATE SHEETS 7 12 TAYLOR MADE GOLF CARLSBAD RESEARCH CENTER CARLSBAD, CALIFORNIA JI--97 i-----1i-----1r-------------------~---~--~l---~I----J ~::::::::::::==:~=:::::::::::::-:;-D';:IR::E:,C-;-TO:"R:================-,=D~A=T;E:::===c=-=-=-,=-, EN :A,NTEEER olFNITwloARLK REVISION DESCRIPTION DATE INITIAL DATE INITIAL ~~Igsi(----1-············~~~.cT.-l:o. o;~:1~;:o j ~ OT~ER A='PROVAL CITY APPROVAL L_____:::_F' C.M.W.D. JOB NO. ~~~6~-2~4~4~----- ' N N: f"INISH GRADE fOL\L o,· 2.0' MINIMJM E;_XTEND 10: MINIMUMA EX-END 10' I/IN MUI ON ~ lill:.R SIDI:. 'tj ON ll fHlR S Dt:: ~~-=---0 ~---"OT ABLE WATER LINE \ SLEEVE PER SPECIFICATIONS CONSTANT PRESSURE RECI.AIMFD WAT~R I NF PRESSURE RECLAIMED WATER LINE AND POTABLE WATER LINE CROSSING NOT TO SCALE CARSON iNOUS IRlfS Rf:(; IANGUI.AR --- VAi_ VE BOX #14129-178 WITH PURPLE BOLT DOWN COVER OR APPROVED EQUAL ,----2" IN GROUND COVER, / FLUSH IN LAWN / 4-1/2"± Rf MO ff CCt\ TROL -----VAi Vr: I _I I r ----------;:;---'7\,-;/.-+.----~e~ 8 0 ·71 -SCH 80 1.HCh-,ZB:.-=:+----1rC::.ELL PVC MALE ADAPTOR SCH 80 PVC BRICK (6 REQ'D) __ _, SCH 80 ,lAINLINE _____ __,,-PVC TEE NO-TS: ALL RC VALVES 0 0~ JSE WI-H RECLAIMED WATER SH.ALL BE PURP_E, AND HAVE i.O. TAGS '//r. PER SPECIFICA-'ONS r \ REMOTE CONTROL VAL VE \J_Q) NOT TO SCALE TREE OR SHRUB ~ // ; LEVEL OR . " ABOVE - ' ' SJRROU 'JDING GRADE ----3" LAYER MULCH / /--8ACKF1La MIX BERM -PLANT TAB- ~~-r,~c, ~(>(')~~~fuI&,~, PLACE A -MI 0-POINT ~-( r DE"TH OF 2X BALL CONTAINER WIDTH TREE AND SHRUB PLANTING NOT TO SCALE ,-----1 /2''(MIN.) 5" DIA ROU'-JD PLASTIC VALVE BOX (PURPLE LID) FINISf-" GRADE --11I-I'' jl--::c \.1ULTI OU'LE T f)llllER OLSO'-J 12 OU n.r, r ----· ----'MA'<LEX' STRff_ T Fl_ FLEXIBLE PVC cu-OFF '-JIPPL[ FLEXI 3LE PVC .160"X 220" CC DISTRIBL TIOt\ TUBING (BURY 6") -SCH LO PVC ~L OR TFE CL200 PVC PIPE DRIP IRRIGATION EMITTERS MUL Tl-OUTLET NOT TO SCALE . ··--·-·--·-·-----·--------------------- L-f-lNISH GRADE ~c---.. .. IMPOl,T[D TOPSOIL (/) l~--I I 137 /7 1_ 11, OR AMC:NDED ROCK ~ ~ I lj u~::I ~{~:_c_ljl11 · ~:~::KEN:1 1 11:~0 SOIL -, 1,: 4" + "llA. (f'Rf ~~LR-Pl Pf ONI.Y) :;:: 8 ~ -"~f-~:l:2c_ ~-------NATIVE SOIL i'.:i[½ '-:ae. MIN,.2 [3/\CK,ILl. ,REE OF Ol · Lt,RGE (1" CIA, OR GREATER) ROCKS MARKtR TAPc · ANC Cf.QRIS (Pli[SSUR= PIP[ ----'.'-'l__; -SAND OR AP"ROVFD ONI_ Y) cOUAL MA l lRIAL 2" 'TVP ' . :rirt-' ,, ---IT::'-1 Ji --_ -J, --·1· J1 •-·--•-JTl= _J li?"O-0' 10:2'1' S}-MJL. IIPLE PIP[ 11--1 .. ' . _-. . . . -_. _-. __ -.JI 1:: IN~_:IAI I A [ION --1IIh ... -, . --· .· -.. -1=•=1 m IAII. (NON- . -------_N~---'---_-_ ---'-...c·-_ rREssuRE 11-... 1-:::·:TTI Hl:---11IC:=1II =111=11 1 l"lf)E C'LY) 1 1 1 :_:I I :.::.:~1 I 1=---,' ,--·-:1 I I::=-cl I t==t I 1-" · '-JOTc:S: 1. CCJMPAC !ION Pl R WA l['< DIST. SP[CIIIC/\ TIONS. 2. NH,~ l'NO CR ~ORf PIPFI __ INFS AR[ INSTALL[C I~ Tl'[ SAME IRf~CH, IH'c"i SI-AL~ Ge INSTALLED SO Tl1AT EA:11 PIPE_INE, VALVE, OR OTIIER PI 0 ELINE CCMPONENT MAY Be SE'IVICED OR REPLACED w:THOUT D:STURBING THE OTHER. B TRENCH DETAIL PVC PIPE 3" AND SMALLER 1 Q NOT TO SCALE co NOTE: N SHRUB SPRAv ROrOR ADJUST PERPENDICULAR TO SLOPE (PURPLE CAI') ---1/2" DIA. G,\LV. PIPE STAKE -CALV. DR CAD. PLA--E) CLAMP MACHINE PEENED FRICTION TVPE (TWO REQUIRED) SCH 80 PVC NIPPLE FINISH GRADE PVC STRC:F T ELL 'MARLEX' STREET EL_ PVC TEE OR ELL LATERAL Ll'-JE SHRUB SPRAY ROTOR ON RISER NOT TO SCALE -rn~ 111= 1=- TREE STAKING NOT TO SCALE '-JOTE: ALL 5 AND 15 GAL TREES SHALL BE STA-<E'l AS SHCW'-J TREc TIE-( 4 REQ'D) IN =-1GU~E "8" SECU'<E TIE TO S-AKE WITH GALV. NAIL TREE STAKE· x8' L.C::NGTH FOR 5 GAL. x•o' lf.NGTH FOR 15 GAi_ PLACE STAKE NEXT TO ROOT BALL \ ' f-l.EXl'll.E PVC 160"X 220" CC DISTRl8UTl0f\ TUBING (BURY 6") ROUTE AS REQJl'<E)-NOT SH ~wr; ON PLAN RIDGID PVC CL200 LATERAL PIPE (GURl[D 12") ALL EMITTERS & PIPE MAY 1'-,0T BE SHOWN 0~ PLAN, !~STALL AS REQU RED BY P _ANT PLACEMENT. MUL Tl OUTLET EMITTER (l'-J BURlf:0 \IA_VE GOX CEN TRt,LL Y I__C)CA HIJ) s SCHEMATIC DIAGRAM FOR DRIP IRRIGATION 10 NOT TO SCALE ---------------------·-·---·· co -.--,,,,,,,.-,i",-----r-·· 1~rlN SH GRADE 111-' ------MARKER TAf0 E ,q-_L__..L._ :t=,_ ___,-BACKf-lLL --BEDDING f~AER AL , o.· · ~ WATER c.lN[ I --DIRECT BURIAL CONTROL __ ---. --·:;::t~ W RES, TIE W/ PLASTIC 1' TAPE EVERY 1 o·. MIN. ~ORMAL LOCATIONS OF CONTROL Wl'IES IMPORTED-- TOPSOIL OR --TT'7""-=--·---,t,i=t- AMcNDED NATIVE_- I I SOIL .-, ,-----t--+-1 DIRECT Bu RIAL;--~ _J, CO'-JTROL WIRE~-- PVC CONDU T AL TERNA TE _OCA-:-1 0N OF CONTROL WIRES C DIRECT BURIAL CONTROL WIRE 1 Q NOT TO SCALE ----CUl,B, --IEADlR, OR WALK SC--1 80 PVC NIPPLE "VC STRcET ELL MAR LEX STRff_ T ELc PVC TEE OR ELL LATERAL LINE NOTE KEEP SPRA v HEAD5 2' CLEAR OF BUILDINGS WHER[ FEASl3L[ 1T POP-UP SPRAY \J__Q/ NOT TO SCALE I ("• I ;f TREE TRUNK NOT:::: INSTALL ROO' BARRIER WHEN TREE IS WITH N 10' OR CLOSER TO HARDSCAPE OR AS NOTED ON THE PLAN. 1 HAROSCAPE ···- ' CURB, MOWSTRIP, WALL, STEP, WALK, -,,1,'-F-"-r-=~cr--m----r,-,-~ .. ,'rl,,,,, BU I LDI NG FOU NC AT -z :::, Cf) I I ---I II~ 1::::::1 I 1:: ::1 . ' .,:~ ION, ROCK, POOL, FOUNTAIN, FENCE POST, PAVING, ETC. [_-11I- 2x BALL WIDTH -"f«XJTXiJ_ll/C/115' R 00 T 8 ARR I ER 18" MIN_ DfcP X 20' MIN. WIDE SEP ARA Tl ON BE'WEEN TREE A'-JD HARDSCAPE. INSTALL ON HARDSCAPE SIDES CNL Y. @) ROOT BARRIER NOT TO SCALE -----COVER / (PURPLE) 2" N GROUr-D COVEC.: I I I . .. DRIP I I F1 L TER FI.USH IN LAWN PRE-SET PRESSURE 1 1 (ROTATE II 11 AS REGL-LATOR I I REQ'D) '._ 1:·----REMOTE CONFWL / / -12" BOX I --._ VALVE--DRIP / I ' I V 1-1 /2"(MIN) A SCH 80 NIPPLE PVC ADAPTOR BRICK (6 REQ'D) Al'JLiNE I I I I I DRIP VALVE ASSEMBLY NOT TO SCALE / . I / , co ,-1 / BAL_ VALVE SCH ELL --SCH PVC 80 BO SCH 80 PVC TEE ---VALVE BOX - J & R f'ROOUCTS r----- / NO. 3 RT, flOX ANJ . 111) MARKt:C "RECLAIMED" ~-----__,______,-I (PURPL~ COVER) ce,j_ \1~1J C LI I 'i-r- 1\ ' N r--------- ., I --~-I/ . 'I1 I -co II I I II I BALL VA_VE J BRICK (2 REQ'D) Jm Irr I MAINLl'-JE ---------------~--PVC MAL::: ADAPTOR @ BALL VALVE 10 r--N_O_T-TO_S_C_A_LE __________ _ ,,__.---WALL 0 CONTROcLER CABlt\ET: MOJNT PER MA'-JUF ACTURER'S INSTRUCTIONS ~-THREADEC CONNECTION BETWEEN CONTROLLER AND CON OU! T --ANCHOR CONDUIT WITH GAL\/INIZC:D PIPE Cl.AMPS AND APPROPR Alf. FASTENERS _.,,_ 2" RIGID STEEL CONDUIT FCR CONTROLLER WIRE NOTE: 7 VERIFY LOCATION WITH OWNER 2. SUPPLY POW~R AS REQUIRED. _j ,,., I WALL MOUNTED CONTROLLER / / 30X SIZE TREE /--1/2" DIA. MIN. 2-PLY / RElt--FORCEJ RUBBER GARDEN HOSE COVERING WIRE AROUND TREE LIMBS ---------TURN 3UCKLE- A"PROPRIATE SIZE- SECU'IE WITH WIRE :::, ' -o.z l..LJ _:i 6' LONG Ml'J. WHITE PLASTIC TUBING ~r"!fi~-'-~~r7"1~-jj--.... -_-~-ii1_1 __ ~1AG~~G~T~~Lc GUY -,--, I :_11.,,.,,f~~~_.,,.,.,,..11 I;' \1 ·~-WIRES ! ---':-i I l------111::-::ffi-=--,.. I ' DEAJMAN-3 EVENLY SPACED 8"x8"x16" /'CJUAI, /. CONG. BLOCKS f()\ TREE GUYING ½) NOT TO SCALE ---F!NISH GRADE AT LAWN (1) REDWOOD 2x4" ( (4) 1/2x4" OR (2) 1 x4" LAMINATED ON SI-' ARP CURVES ) ,-· FINISH GRA)E AT / GROU'-JD COVER I ...... .----.,, 1 -1 / 2" / ....,,;! 1""'1 -1""1 ~, I1 ~1l~~1! 1 ::::TnillJ~ilLJI_ -GAcVANIZED NAIL ~ 1i'-ll11i'l1111~ WHJH11 I,,~= (2) MIN. PER STAKE l1=I11-11111 1II~-.clftsl' 1xJx18" RC:DWCOD jl~rd~ln --1II--dl STAKc, j' o c 111=1 I[:: UllFI Irr I REDWOOD HEADER · II 11['1111::: \, -1x3x18" REDWOOD STAKE I I= ·-111-·11 I \ ,:_1 x4x24" REDWOOD BLOCK -11,_ -I 11c:-' ' ' I . ...,,.,1 ----,,.,_ I I= I 1=1 I I r--, 1::3:j ,__, ~-~--~",, ,:, I ' REDWOOD HEADER NOT TO SCALE SPLICE DETAIL PLAN NOT TO SCALE t -QUICK COJPLc~ VALVE (PURPLc CAP; --S' I~ GROUND COVER, --Nll'l''l 1-. -SCII 3~ l'V'.'. _____ COlJf' INC Nll'l'l F f I I ----Nif'l0 LE -SU-80 l'VC COIJPI .. ING MALL A8A" ILi-< CU f r_ CONCrff TF QUICK COUPLER VAL VE NOT TO SCALE D,EP WATERING DEVICE: NJS # 12 GRl'N GRAff, 4" PER FORA ~EC RIGID D'<A.IN PIPE fl I Fl) WITH PEA GRA'IEL DRIP IUBt 1" ABOVE GR! V[L ( 2 ll-R [ACH !Kl[ N AWN ) 13RrATH,-R TL.[-V N)S ~ 12 GRE:N GRAff, 4" Pf.RF ORA 'lC Rl[;l0 ORAN PIP[ WRAPP[D W>H GEOTEXTILE FILTER _-Alil!IC SJRROUNDFD wm-P~A GRAVEL N 12" DIA. IIDLc ( 1 / 15 CAL 2 / 24" BOX ) ( 2 PER EACH PALV T,EE) Sl[ HE A.10 SHRUB Fl,ANTINS fu DElAIL FOR OlliER R:CUIREMENTS Qg_) -------------------------·------- NOTES: 1.Tll[RE SHALL BE NO FITTI~GS OR CONNECT:ONS TO □-HER FACILITIES BETWEEN THE METER /\N) IJACK,L_OW ASSE:M3L Y. fj_ 2.1JAcKr·1 __ cw PREVENTEC: ~AY NOT GE I INSTALL[) IN °UBI_IC RIGHT OF WAY. .1CONSIRIJCT ;:>' HIGH RETAil\l,\JG 1 w.•.I I or-. ,) STC[S OF [JACKFI_QW I l'RI-Vf_Nffl, Wll[N INST.AEL[C ON I ~ 4 OR Gl,[A 1[, SLOPE. OP[~ END (;'\ r,;--., ""' ~__;---r7'\ (3 SI-AU_ 13[ AT 001/Nll!Ll_ SIDE 01 1 ·'.) \...4.J \.._4_; SI.OP[, f'l<OVIDE 2' HORIZONTAL I • (_;1_[/\RANCE BETWEEN WAL_ AND I f F'ff -~~ Q,_ H rACKFLOW PREVENTER. ~~=-~ ~~~~=~ 4.1:::0 NOT INSTALL IN A~EA I 2' J'-'; 4' l---{s: SUl,J[CT TO f"LOO): NG .___ I IY '-:,_; ! ;;:_ ·· ir -ij~ -----(;) CJ) I -----w . 3G MAX_ ---FINl~H ,~,::::::::~7'1i ~-~ ... 9'. \'. '.' "0 ' _-•0 •. ·.' •• '.11 % ii . _1_, iTT~/-1' -I I [ 11 4· CONG. Pi\Djl,, T' -, _ ii ME:TER i :;:I ' -1 2000 PSI ' -, /--...., : : r 7 f ' B I--I ' ' I 1°-;" I,\___ p \__:,_., '_j ir::~i-_~:r r 11 ,_ -~-i----0) 1.__?.,;--,1"'0>" .. -11,="--"-- // 3 3 '' I\ )) PUBLIC PRIVATE ;:------------~:../ ~ CONSUMERS RESPONSIBILITY CARLSBAD Rfi/1 ST Off APPR DAT- TO BC: INSTALLED 0 URSUANT TO ~UNfCIPAL CODE BOOK 14. 06. 010, 4C01-S~C. 58, 1l 1LE 17 Of THE CA'_fFOR\IA AcMINfSTRATIVE CODE. MUNICIPAL WATER 2 INCH AND UNDER BACKFLOW INSTALLATION DISTRICT STD DWG. NO. W20 AUGUS" 1993 ,IJ\ DEEP WATERING DEVICE / BREATHER TUBE '\J__Q) NOT TO SCALE RP. 8ACKFLOW ASSEMBLY NOT TO SCALE PLANTS PER PLAN --SPACING PcR P _AN -CENTER OF PLANT 1 /2 SPAC:ING ,ROM ,·1 x:::D IMPRCVc.M[N T: TYPICAL INSTALLATION LAWt\ INSTALLATION .----11\ SECT CAP INSECT CAF GRATE" -2" ABOVE GRADE OR MULCH WHERC: OCCURS J . ' ' / \ I ' I f/ULCH FIN. GRD. FLEXIBLE PVC 160"X 220" 0.), DISTRIBUTION TIJBl'JG --TREE OR SHRL:B FI . .EX Bl.E PVC -6CJ"X 220" G.D. DISTRIBL:TION TUBING 6" MN, DEPTH FOR TUBING MUL Tl OUTLET EMITTER IN 5" ROUND VALVE BOX FIN. GRO PIPE GRAVt:. \ ___ DEEP WATERl~G TUBE FOR DRIP INSTAl.LATION TO TREES IN LAWN AREAS. SEE DETAIL T--11S SH~[-;- @ CURB, WALK, HEADER, E-C. 00 TRIANGULAR SPACING NOT TO SCALE SOa'.. ~(l''-"· ;·c '.·:e ''.I/ :: .. '. :,c;,· , ~,:Jll : C·, ,,; /" 'C: ENGINEER'S SIGNATURE R[CUIRrD ON "AC[ I ONLY APPROVED: ENGINEERING Pl.AN CHrcn~ DAIT APPROVED FOR PLANT! NG AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS . ' SHt.lf i I 12 "AS BUILT" 1),:.1[ . . -· ,. ·---···-·· ···--·-·-·. ···----INSPECTOR DATE CITY ◊F-CARTSBAD SH,ETS 1 2 TAYLOR MADE GOLF I CARLSBAD RESEARCH CENTER CARLSBAD, CALIFORNIA i;~;~~v~~~~~;( M.-- A~SISfA_N~ •D!;fCT_O, _~--OAT[ i-----t-----t----------------+---+----f---1-------f DWN 8\: PROJECT ~0 DATE INITIAL DATE INITlt,L ~Ml ,NlllAL CRAWING NO. >----~--f----~-----1 . CH~D RY. H DP96-l41 I _RVWD __ BY,_ E,GINEER or WORK REVISiON OESCRIF'TION OTHER APPROVAi CITY APPROVAL 1-.fl_:-JL. C _ M _ W _ D. JOB NO_ ~==~f.._,~.._-__,,~c::..lf.!......!I/_ ~-------------------------------------------------------------------------------,--....... . --------------------------------------------------. -·-----·· --------------- "I, -.----•-------=~~~-----~~----------------------------------------.----------···7 · / -FINISH Gl~ADt / ___ TOT6L m-20' MINIM=U=M-~_ EXTEt-.P 1 O' MINIMUJA~TENDJO' MINIMUM ON EITHER SIDE 'tj ON EITHER SIDE __ .------~ ·i :!'::!;;, ="i:i·oTABLE WATER LINE ::,:o :: :_J N!w -, -SLEEVE PER SPECIFICATICNS .-1m \ --iv-----..r'.. .. , -~~ 1 -CONSTANT PRESSURE RECLAI\A[D WATER LNE PR~SSURE RECLAIMED WATER LINE AND POTABLE WATER LINE CROSSING NOT TO SCALE CARSON INDUSTRIES RECTANGULAR. VALVE BOX #14129-128 WITH PURPLE BOLT DOWN COVER OR APPROVED EQUAL 2" IN GROUND COVER; FLUSH IN LAWN 4-1 /2"± PVC MALE ADAPTOR BR]CK (6 REQ'D) __ _,,. REMO~E CONTPOL VALVE SCH 80 PVC SCH 80 MAINLINE _____ _, PVC TEE .... --··;·,. NOT~S: ALL RC VALVES FOR USS WITH RECLAIMED WATER SYALL BE PURPLE, AND HAVE i.D. TAGS PER S"ECIFICAT10NS REMOTE CONTROL VALVE NOT TO SCALE TREE AND SHRUB PLANTING NOT TO SCALE -6" DIA ROUND PLASTIC 1 1/2'.(MIN.) // VALVE BOX (D~RPLE LID) · FINISH GRADE A • -m:-•:T' .1.,-MUL Tl OUTLET EMITTER OLSON 12 OUTLET ! ', ', 'MARLEX' STREET EL · --Fl_[XIBLE PVC CUTOFF NIPPLE ',",. '·~ FLEXIBLE PVC . 160"X.220" OD DISTRIGUTIO'< TUBING (GURY 6") ' "- '"-"-. •~ SCH 40 PVC EL OR , TEE "' - "''-CL200 PVC PIPE DRIP IRRIGATION EMITTERS MULTI-OUTLET NOT TO SCALE ' 00 ' -+- 00 NOTE: FINISH GRADE ·--"--c,-1-=IMPORTFD TOPSOIL 1- 1 _1 r OR AMr:NDED 'ROCK = FREE t,ATIVE SOIL 1--11 ----i--~.-~MARKER TAPE (PPESSURE PIPE ONLY) -SHRUB ·SPRAY ROTOR ADJUST PERPENDICULAR TO SLOPE. (PURPLE CAP) ··· 1/2" CJIA. GALV. PIPE STAKE GALV. OR CAD. PLATED CLAMP MACHINE PEENED FR!CTION TYPE (TWO REQUIRED) SCH BO PVC NIPPLE FINISH GRADE .i.11! Ip I • PVC STREET ELL '' 'MARL EX' STREET ELL "' -PVC TEE QR !;:LL LATERAL LINE SHRUB SPRAY ROTOR ON RISER NOT TO SCALE NOTE: ALL 5 AND 15 GAL. TREES SHALL BE STAKED AS SHOWN -:-------.. SECURE TIE TO STAKE WITH GALV. NAIL TREE STAKING NOT TO SCALE ---TREE STAKE: xB' LENGTH FOR 5 GAL. x1 o· LENGTH FOR 15 GAL. / ' I FLEXIBLE PVC· .16D"X.220" OD DISTRIBUTION TUBING (BURY 6") ROUTE AS REQUIRED-NOT SHOW\ ON PLAN. , / RIDGID PVC CL200 \ \ LATERAL PIPE ALL EMITTERS & PIPE MAY NOT · BE SHOWN ON PLAN, INSTALL AS REQUIRED BY PLANT PLACEMENT. \ (BURIED 12'.) \_ MULTI OUTLET EMITTER (IN BURIED VALVE BOX CENTRALLY LOCATED) SCHEMATIC DIAGRAM FOR DRIP IRRIGATION NOT TO SC:ALE -FINISH GRADE ~..-,-,,=,---+-,-~-'--rrT-,,.;;-·,,..,-,= . ··111-_' _.,.. MARKER TAPE __L_~~l'-f~ -~-BACKFI .• L. -BEODING MATERIAL -----~-WATER LINE PVC CONDUIT Al TERNA TE LOCATION OF CONTROL WIRES DIRECT BURIAL CONTROL WIRE NOT TO SCALE ___.,---1..UR8, HEADER. OR WALK POP··UP SPRAY (PURPLE CAP) 11 :JI'- II Ill~-I ,. -SCH 80 PVC ff'" NIPPLE PVC STREET ELL MARI.EX STRtET ELL PVC TEE OR ELL NOTE: . KE~P SPRAY HEADS 2· C_EAR o~ BUILDINGS WHC:RE ~EASIBLE. @· POP-UP SPRAY 1 Q NOT TO SCALE i 'I '_Ld ~ TREE TRUNK 7 'I · /,-NOTE: INSTALL ROOT BARRIER /, / WHEN TREE 1s WIT_HIN 1 o· OR _, l CLOSER TO HARDSCAPE OR I I AS NOTED ON THE P~AN, < · , -HARDSCAPE -- / CURB, MOWSTRIP, WALL, STEP, WALK, , _ _.,_ BUILDl'JG FOUNDA T- ~ l=i i · I - 1 _1 ~.._ ION, ROCK, POOL, = = FOUNTAIN, FENCE 'co 11 -----ill~ POST, "PAVING, ETC. ~, =1 11 ::t i=I 11..: :.I 1.-- --··-"{<(XJT'::c,/.1/i/4115' ROOT BARRIER f-TTT-18" MIN. DEEP X 20' MIN. WIDf. 2X-BAL_L___ SEPARATION BEiW[E'J TREE WIDTH AND HARDSCAPE. INSTAU. CN HARDSCAPE S'CES ONLY, @ ROOT BARRIER 1--1/2"(MIN) X SCH 80 Nl?PLE / --J / /,............ / / _.,,, .....__..,.....,_,, PVC .ADAPTOR ---1 //.--//_, BRICK (6 REQ'D) __ / -"/. AINLiNC-------•-----... / DRIP VALVE ASSEMBLY NOT TO SCALE L SCH 80 PVC TEE VALVE BOX - ,J & R PRODUCTS NO, 3 RT, BOX AND , Ill) MARKED "RECLAIMED" 00 ,- I Jn (PURPLE COV~R) "\ __ ffi:1:i;~ 111 ·- BALL VALVE BRIC'< (2 REQ'O) ··•· MAINLINE -~--~ ........ ----~---PVC MALE BALL VALVE NOT TO SCALE 0 ADAPTOR ...---WA!L ., -CON TROLLER CABINET: MOUNT PER MANUFACTURER'S 1 INSTRUCTIONS __.--THREADED CONNECTION BETWEEN CONTROI_LER AND CONDUIT ----ANCHOR CONDUIT WITH GALVINIZED PIPE CLAMPS AND APPROPRIATE FASTENERS ---._ 2" RIGID STEEL CONDUIT FcJR CONTROLLER WIRE Frre"i• :;:,n,=-,;:,;:;,,~, -3/4" RIGID STEE_ :::m~---'ITf___ 1----111-111-1 CONDUIT FcJR ,~11 i-·-1 i I i I i II nt ;,: POW~R SUPPL y ' ~ :I I i~I I l1 c::::,1~J:::-·-1, ~1 ~::_; 111:::=--::' :;:::'. ;r-12" RADIUS MIN. · ----::JI El 14 -. . SWEEP ELL , ,-i ' ::-::tJ:::::::::;,➔ TO PULL BOX NOTE: 1. VERIFY LOCATION WITH OWNER. 2. SUPPLY POWER AS REQUIRt·'.D. ;;j_ I WALL MOUNTED CONTROLLER /-BOX SIZE TREE / ✓-1/2" DIA. MIN. 2-PLY / ,/ REINFcJRCED // RUBBER DARDEN /' HOSE COV~R!NG WIRE AROUND TREE LIMBS -----TURN BUCK~E- APPROPRIA TE SIZE- SECURE WITH WI'<~ :::, . O.z w-::, ,/~ ~~;rtg ~0~·1N~HITE TREE GUYfNG NOT TO SCALE / ' //' -FINISH · LAWN GRADE AT //// · (1) REDWOOD 2x4" ( (4) 1/2x4" OR (2) 1 x4" LAMINATED ON SHARP CURVES ) 1 FINISH GRADE AT / GROU~D COVER I //1 "-•-' ~-.---, 1-1/2" c--II=II= ll 11 1=1 I 1"7"rt-~ lru"-'-'.II [J I i="/ I =111] Ill,, '---' 7.IiSJ:UC:: . GALVANIZED NAIL Mn1Yrr-~l,1rIThl 1I1i11I11!1.~r (2) MIN, P[R STAKE ll=,1] .... III ii III=[[}•-;l' 1x3x18" REDWOOD 11111111!11 ,1µnr~ STAKE. 5• o.c . :TiT 111::: 'Ti! IT , REDWOOD HEADER .--/1 Ill ll' \ ,--1x3x18" RFDWOOD STAKE ll= ~Ll""."'rl \ \ ,:.1_ x4x24·' REDWOOD fll.OCK n1li1 1 T'-1 ~Ti \ p -"'9 , /i I 1 REDWOOD HEADER NOT TO SCALE SPLICE DETAIL PLAN NOT TO SCALE ,, ·1 ·-·-OUICK COUPLER VALVE (PURl''LE CAP) 3" IN GROUND COV[R, Hfn---,rr-NOT[: ALL FITTINGS ' ThRD. SC~. 80 PVC NIPPLE -SCH 80 PVC ____ COUPLING NIPPLE •• ELL ----NIPPLE -SCH BO r0 vc COUPLING MALE ADAPTF:R .-• -. l• ':--~'LJ-1,.-L._J--_u--MAINLINE -~: ► '·'9:, . ·'\) .-" • v' • ---1 /2 CU. FT. CONCRETE QUICK COUPLER VALVE NOT TO SCALE ' ' ' ' ' ' I , ; ---DEEP WATERING DEVICE: / NOS # '2 G,EEN GRATE, : 4" Pc.i<FORATED R GIO >[A GRAVEL. / DRAIN PIPE FILLED WITH uRIP TU3i 2" ABOVE GRA \U / ( 2 PER EACH lREE IN LA~N ) " ' ; I _;-BREATIIIER T~BE: / NDS # 12 GREEN GRATE, / 4" PERFORATED RIGID / DRAIN PIPE WRAPPED WITH / / GFDTEXTILE FILTER FAB~IC SU'lROUNDED WITH PEA / GRAVEL iN 12" DIA. HOLE / ( 1 / 15 GAL 2 / 14" BOX ) / ( 2 PER EACH PALM TREE ) I /-FINISH GRADE t:i<'l<~i:,;f:J;; •~l±i°lrJIH.le!I~-. -3' M1Nl~UM ABOVE GRADE AT " 1n : I J \ GROUND CO\'t:R, FLU'.li IN LA~ ~ ;,--=,i _ .. , . _ : §.~-,1--12' MIN. DIAMETER HOLE ~ U1 L=11 I_ I i I .. ; I , ] I i1 ~ B[_OW TREE PLANTING PIT ~ ' ,-, 1 1.11, / : , j_l 1 "' Sff 'REE AND SHRUB PW/TING ffi J 10 :1 I. CONT AIN[F_ · '-::-'' DElAI •. 'al OHR REQUIRmENTS \Jg7 DEEP WATERING DEVICE BREATHER TUBE NOT TO SCALE .~PLAN~s PER PLAN ~SPACING PER PLAN TRIANGULAR SPACING NOT TO SCALE CENTER OF PLANT 1 /2 SPACING FROM FIXED IMPROVEMENT: CURB, WALK, HEADER, ETC, NOTES: 1.Tlll'RC: SHALL BE NO FITTINGS OR CONNECTIONS TO OTHER FACILITIFS BETWEEN T~E ~ETER AND 8ACKFLOW ASSEMBLY.l 2,9ACKFL.CW PREVENTER ~AY NOT BE I INSTALi.Eil f~ PUBLIC RIGHT-OF-WAY. 3.CONS1RUCT 2' HIGI" RETAINING 1 WAI_L ON 3 SI DES OF BACKFLOW I CORf::VF:NTER WHEN I ~STALLED ON I -~ 4 ·. OR G,EATER SLOPF. OPEN END 3 T ~-I 3 SHAl_l_ BE AT DOWNHI''. SIDE Of" 1 s1 .. 0l"E. PROVIDE 2' rlOR'ZONTAI_ I CL .. FARANCE B=TW[FN WALL AHD I Fil r Cl> :J! 'IF BACKFLOW PREVENl[P. -n ~ n 4. DO NOT l NS TALL IN ARE A I 2' i!r ~_.A_, i,tt=,._ ___ :_;::;_..::;::J, SUBJECT TO FLOOD I NG. 1' MAX. __ IJ_"').J=JY__ -{~) 12· MIN. lo\ _ G. MAX. 2 ·~ 0) _ _ J , 3G· MM. _ ~~~ii!1 ---,----·······-------1-1<::!."A.1_ I ~1•,--1, Wt_ 1\.~ ,· •.•_ ,.-_ ... ,.-@ > •·_ .. ,. '-1".' .• ~_: > ~--_ ·1 ~ I= ::-:-::-.:::: i -' -~,' _,.:,;:;_' .... , ,'<', • .. '5:1.,.m.-~• 1,1 _;_, I == •. • -------------• I I . . ----. . . ' ft-. 11 i-1 I 1= I' '---~' 1:::··11 4. CONC. PAD I I?.' MEITl="R _, . ' -1 2000 PSI . ' _, re\ _ 1__ I 1 -: .. ;:\;,7 , ~ •11--<'.:-~·-• __ c:::::· -~" +---{!) G}·.,r,.~J:';\B'• --1 I; .,,,_. __ ,... . .. I .. )) I -; ,, 3 I \ ); PUBLIC PRIVATE CONSUMERS RESPONSIBILITY c.:::::::::::::::::=::::/ --'111111 ""'---• •~m, c-..,.,., TO BE INSTALLED PURSUANT TO MUN-;C!PrcoDE GOOK 14 08. 010, 4001-s,c. 58, TITLE 17 OF THE CALIFORNIA AD~lNISTRATIVE CODE. l-----l--------·---------·--------------1-------1 CARLSBAD R"vlsTBN APPR DA TE ., .• ~ ....... ,-- 1---~f---< ., .. ~-- MUNICIPAL WATER 2 INCH AND UNDER BACKFLOW INSTALLATION R.P. 8ACKFLOW ASSEMBLY NOT TO SCALE DISTRICT STD. DWG. NO. W20 AUGUST 1 \l93 TYPICAL INSTALLATION LAWN INSTALLATION _.,--INSEC-CAP .., ..... ...----..... //-2" ABOVE GRADE OR ,.x-MULCH WHERE OCCURS · MULCH _ _.,. · FIN. GRD. FLEXIBLE PVC .160"X. 220" -O.D. DISTRIBUTION TUBING /~ TREE OR SHRUB // FLEXIBLE PVC .160"X.220" ' 11 O.D. DISTR 1BUTION TUBING I / -6" MIN. DEPTH 1 / FOR TUBING -1 MUI. Tl OUTLET EMITTER \ •N o" ROUND VALVE BOX EMITTER TUBING INSTALLATION NOT TO SCALE . / / 0 ,---,NSECT CAP _, -GRATE ·· Fir.. GRD. DEEP WA TERI NG TUBE FOR DRIP INSTAL~ATION TO TREES l'I LAWN AREAS. SEE DETAIL THIS SHEET. @ ¥ WIiey Group l,..~11iluap■ lrthll•c. h1r•. ,< rn F;oy Wiley. ,>,,':_:,._,.A llSllQ f!OVCJC Rd$(~ 1"(1(.-lil.'l _a,·,ds.C.QP•~ Arc.-,,.,,_.,. ~·,cu1 [l;~qo, CA cl;Jl 18 APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE "AS BUILT" NAME DATE TITLE; ENG/NE~R'S 5/GNATUF?E RECUIRED ON ,':'lAG[ 1 ONLY APr~ovt:D: ENGINEERING P .AN CHECKER DATE .,,, .. , __ LOCATION OF PLANTING AREAS REVl[W~I) BY: -----.... •'•"-"""'"-'""- INS"'ECTOR DATF. CITY OF CARLSBAD _j' ISHLETS ·: PLANNIN~ DEPAP.TMl'."W ____ Lli ..... ; C.M,W.D. JOB NO. .,, ~ ~I/I/