HomeMy WebLinkAbout2548 CAMPBELL PL; ; FPC2021-0130; PermitPERMIT REPORT Fire Permit Print Date: 09/14/2021 Job Address: 2548 CAMPBELL PL, CARLSBAD, CA 92009-1700 Permit Type: FIRE-Construction Commercial Work Class: Parcel#: 2132611700 Track#: Valuation: $17,441.25 Lot#: Occupancy Group: Project#: #of Dwelling Units: Plan#: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Project Title: Description: VIASAT N4 -SPRINKLER Tl (6 HEADS) THERMAL CHAMBER Applicant: TITAN FIRE PROTECTION INC EDUARDO MARTINEZ 1341 DISTRIBUTION WAY, # STE 14 VISTA, CA 92081-8843 (760) 295-3436 FEE FIRE NFPA 13 or 13R System 6 heads or less Fire Sprinklers Total Fees: $125.00 Total Payments To Date: $125.00 Fire Department Ccityof Carlsbad Permit No: FPC2021-0130 Status: Closed -Finaled Applied: 07/14/2021 Issued: 08/09/2021 Finaled Close Out: 09/14/2021 Inspector: Final Inspection: FPContractor: TITAN FIRE PROTECTION INC 1341 DISTRIBUTION WAY, # STE 14 VISTA, CA 92081-8843 (760) 295-3436 Balance Due: AMOUNT $125.00 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-4665 I 760-602-8561 f I www.carlsbadca.gov Fire Protection Contractor -License #989280 FIRE SUPPRESSION MATERIAL SUBMITTAL: PRODUCT DATA AND MANUFACTURER'S INSTRUCTIONS 21486 ViaSat N4 THERMAL CHAMBER T.I. 2548 CAMPBELL PLACE Carlsbad, CA 92009 "IKINCG® TECHNICAL DATA Page 1 of 6 MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 289-845-9501 Technlcal Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1. DESCRIPTION The Viking Microfast® Quick Response Pendent Sprinkler VK302 is a small ther- mosensitive glass bulb spray sprinkler available with various finishes and tempera- ture ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive environments and are Listed and Approved as indicated in the Approval Charts. 2. LISTINGS AND APPROVALS .®,, cULus Listed: Category VNIV ~ FM Approved: Class Series 2000 ~ VdS Approved: Certificates G414009, G414010, G4040095, and 4880045 ::.0 · LPCB Approved: Certificate 096e/06 /4\. WARNING· cancer end ~uettve Ham-; ~ www.P65Wamings.ca.gov ( E CE Certified: Standard EN 12259-1, certificate of constancy of performance 0832-CPR-S0021 @ CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) • MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-factor: 5.6 U.S. (80.6 metric .. ) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-C51000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated SprjQklers· Belleville Spring-Exposed For ENT Coated Sprjnklers· Belleville Spring-Exposed, Screw and Pipcap -ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135 °F (57 °C) =A, 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C) = G Form No. F _033314 19.02.21 Rev 19.1 Replaces Form No. F _033314 Rev 18.1.P65 (Removed F-1 Escutcheon.) Page 2 of 6 'JIKINCG® TECHNICAL DATA MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.viklnggroupinc.com For example, sprinkler VK302 with a Brass finish and a 155 'F (68 'C) temperature rating= Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Sprinkler Wrenches: A. Standard Wrench: Part No. 21475M/B. B. Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B .. (available since 2006) C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool ... Part No. 15915 (available since 2010) **A½" ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F _051808. Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A (available since 1971) B. Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfasl® Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Flat Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F _033314 19.02.21 Rev 19.1 Page 3 of 6 TECHNICAL DATA MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (KS.6) The Viking Corporation, 21 0 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@viklngcorp.com Visit the Viking website for the latest edition of this technical data page: www.viklnggroupinc.com TABLE 1 · AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary 135 'F (57 'C) 100 'F (38 'C) Orange Ordinary 155 'F (68 'C) 100 'F (38 'C) Red Intermediate 175 'F (79 'C) 150 'F (65 'C) Yellow Intermediate 200 'F (93 'C) 150 'F (65 'C) Green High 286 'F (141 'C) 225 'F (107 'C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings': White Polyester, and Black Polyester. ENT in all temperature ratings except 135 'F (57 'C) Footnotes , The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. Sprinkler wrench 13655W/B** for recessed pendent sprinklers ** A 1/2" ratchet is required (not available from Viking) .. .. For ENT coated automatic sprinklers, the waterway is coated. Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Form No. F _033314 19.02.21 Rev 19.1 Page 4 of 6 I TECHNICAL DATA I MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (KS.6) The Viking Corporation, 21 0 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-845-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking webtllte for the latest edition of this technical data page: www.vikinggroupinc.com Base Thread Size Part SIN Sprinkler Number1 Style NPT BSP 12979 VK302 Pendent 1/2" 15mm 19780 VK302 Pendent 1/2" 21354 VK302 Pendent 15mm Nominal Overall K-factor Length U.S. metrtc2 Inches mm 5.6 80.6 2-1/4 58 5.6 80.6 2-1/4 58 5.6 80.6 2-1/4 58 Approved Finishes cULus4 VdS LPCB A1Z, B1Y, D2, C2X A1 A1Z,B1Y D1Z,C1Y D1 Approved Escutcheons X -Standard surface-mounted escutcheon or the Viking Micromatic® Model E-1 Recessed Escutcheon Q[• D3 D3 Approved Temperature Ratings A-135 'F (57 'C), 155 'F (68 'C), 175 'F (79 'C), 200 'F (93 'C), 286 'F (141 'C) B-135 "F (57 'C), 155 'F (68 'C), 175 'F (79 'C), and 200 'F (93 'C) 1 -Brass, Chrome, White Polyester6·e, Black Polyes- ter6·6 2 -ENT5 3 -Chrome Y -Standard surface-mounted escutcheon or recessed with the Viking Micromatic® Model E-1, E-2, or E-3 Recessed Escutcheon C-155 'F (68 'C), 175 'F (79 "C), and 200 "F (93 'C) D -155 "F (68 "C), 175 "F (79 "C), 200 "F (93 'C), 286 'F (141 'C) Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. Z -Standard surface-mounted escutcheon 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. 4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 cULus Listed as corrosion-resistant. 8 Other colors are available on request with the same Listings and Approvals as the standard colors. 7 CE Certified, Standard EN 12259-1, EC-certificate of constancy of performance 0832-CPR-S0021. 8 MED Certified, Standard EN 12259-1, EC-0832-MED-1003. cULus Ustina Beauiremeots; The Viking Microfast® Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary occupancies. • The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F _091699 -Care and Handling of Sprinklers. Also refer to Form No. F _080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed In accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F _033314 19.02.21 Rev 19.1 TECHNICAL DATA Page 5 of6 MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 18021 Approved Temperature Ratings A -135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C) B -135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) C -155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C) D -155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C) Approved Finishes 1 -Brass, Chrome, White Polyester', and Black Polyester' 2 -ENT' Footnotes , Base part number shown. For complete part number, refer to Viking's current price schedule. A1Z, B1Y Approved Escutcheons X Standard surface-mounted escutcheon or the Viking Micromatic® Model E-1 Recessed Escutcheon Y -Standard surface-mounted escutcheon or recessed with the Viking Micromatic® Model E-1 or E-2 Recessed Escutcheon Z -Standard surface-mounted escutcheon 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the FM Approvals available at the time of printing. Other approvals may be in process. 4 Other colors are available on request with the same Approvals as the standard colors. 5 FM approved as corrosion proofing for corrosive environments. The Viking Microfast® Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F _091699 -Care and Handling of Sprinklers. Also refer to Form No. F _080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. FormNo.F_033314 19.02.21 Rev19.1 Page 6 of 6 TECHNICAL DATA MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vlkingcorp.com Vlslt the Viking website for the latest edition of this technical data page: www.vlkinggroupinc.com 1/2" Installed with a standard 1/8" surface-mounted escutcheon Celling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum Figure 3: Sprinkler Dimensions with a Standard Escutcheon • ♦ 1-3/4" (45 mm) Max. t .... 2-1/8"-+ (54 mm) 4 1 Installed with a Model E-1 Recessed Escutcheon --2-1/8" , . (54 mm ~-' ' -~·----.,,~ ~ . "' . 1-1/8" (29 mm) 2'"' Min. (51 mm) Max. t Installed with a Model E-2 Thread-on Recessed Escutcheon Celling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum 1-1/8" (29 mm) Min. Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F _033314 19.02.21 Rev 19.1 Replaces Form No. F_033314 Rev 18.1.P65 (Removed F-1 Escutcheon.) Bull Moose Tube'S-Schedule 1 O and Schedule 40 are FM Approved and UL listed (for U.S. and Canada), even though these products do not require separate approvals and lis1ings. Bull Moose rime-made the decision to have them approved and lis1ed. Our Schedule 1 O and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's• Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM A 123 standards. All products are stencilled to meet FM & UL specifications. c®usLISTED m ~ ~41d NPPK ...-- 4 SCHEDULE 1D PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATERFIUED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1.315 1.097 1S.27 1.41 lbs/ft 1.820 91 1-1/4 1.660 1.442 9.9t 1.81 lbrlft 2.5t8 61 1-112 1.900 1.682 7.76 2.09 lbs/ft 3.053 61 2 2.375 2.157 6.27 2.64 lbrlft 4.223 37 2-112 2.875 2.635 4.92 3.53 lbs/ft 5.893 30 3 3.500 3.260 3.54 4.341bslft 1.'Y.il 19 4 4.500 4.260 2.50 5.62 lbs/ft 11.796 19 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE 0.D. I.D. WATER FIUED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.049 1.00 1.68 lbs/ft 2.055 70 1-1/4 1.660 1.380 1.00 2.27 lbslft 2.918 51 1-112 1.900 1.610 1.00 2.72 lbs/ft 3.602 44 2 2.375 2.067 1.00 3.66 lbs/ft 5.114 30 2-112* 2.875 2.468 1.00 S.80 lbs/ft 7.875 30 3• 3.500 3.068 1.00 7.58 lbrlft 10.783 19 4* 4.500 4.026 1.00 10.80 lbs/ft 16.316 19 •en~ available ill Casa Graodo,AZ °Cooosion Resistance Ratio per latesl UL Oirecto,y Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale. dirt, chips. grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ....... ,...__ 'ftaaCll:INlll#l't For Additional Information Contact (800) 325-4467 Or From Canada Call: (800) 882-4666 1819 Clarl<son Road Chestemeld. MO 63017 Gerald. MO casa Grande, W. www.bullmoosetube.com sales0bullmoose1ube.com Dallas. TX Maslry. OH Bull Moose Tube's• Eddythread «>- is a lightweight replacement for Schedule 40 that has a Corrosion Resistance Ratio of 1. c®usLISTED <19 APl'IIMll ADVANTAGES OF BULL MOOSE TUBE® EOOYTHREAO 40® • Has a Corrosion Resistance Ratio of 1.0. • Has a pressure rating of 300 psi. • Is lighter weight than Schedule 40. • Is approved by Factory Mutual and listed by Underwriters Laboratories. • Is produced in accordance to ASTM A 135 and A795 Type E, Grade A. • Can be used with standard Schedule 40 threaded fittings. couplings, and valves. • Is produced from steel with excellent properties of strength and threadability. • Can be used in wet, preaction, and deluge type sprinkler systems. • Can be hot dipped galvanized to meet FM's requirement for dry systems. • Offers lower freight costs. • Supplied with EDDY GUARD 11e MIC preventative coating. EOOYTHREAO 40® SPECIFICATIONS NOMINAL PIPE O.D. I.D. WEIGHT WATER FIUED BUNDLE SIZE (IN) (IN) (IN) CRR* LB./FT WEIGHT SIZE 1 1.295 1.083 1.00 1.461 1.860 70 1-1/4 1.650 1.418 1.00 2.070 2.754 51 1-1/2 1.900 1.654 1.00 2.547 3.468 44 2 2.375 2.123 1.00 3.308 4.842 30 ·corrosion Rtsistance Ratio per lmst UL DlrKtory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket. pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt. chips. grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 Or From Canada Call: (800) 882-4666 1819 Clarkson Road Cheste<field, MO 63017 Gerald, MO Casa Grande, AZ www.bullmoosetube.com salesObullmoosetube.com Dalla,, TX ~Ott 5 Bull Moose Tube'S-Eddyl~ is a lightwall threadable pipe manufactured in NPS 1 • through 2". Eddylite• is a truly unique product within the fire protection industry. lhis product has been engineered to provide lower cost fire protection systems without compromising service life. adequate wall thickness, or standard outside diameter. Eddylite" is manufactured to meet the requirements of ASTM A 135 and A795 specifications. lhis pipe product has been fully appnwed by Factory Mutual, and listed by Underwriters Laboratories (for U.S. and Canada) for use in fire protection systems with a working pressure of 300 psi or less. 6 c®usLISTED <1'> Al'PIMD ADVANTAGES OF BULL MOOSE TUBE® EDDYLITE"' • Standard outside diameter, unlike some other lightwall threadable pipe products. • Lighter in weight than Schedule 40. • Superior burst strength and corrosion resistance ratio compared to other lightwall threadable pipe products. • Exceptionally strong, meets or exceeds ASTM A 135 minimum yield requirements. • Can be used with standard couplings, fittings, and valves. • Freight savings. • lower sprinkler system costs without compromising service life. • Better hydraulics than Schedule 40. • Wall thickness and weight close to Schedule 30; compare to other lightwall threadable water filled products with wall thickness less than Schedule 101 CORROSION RESISTANCE RATIO (CRR) NOMINAL STANDARD INSIDE UL UL WEIGHT WATER PIPE SIZE (IN) O.D. (IN) DIAMETER (IN) THREADED UNTHREADED PER FT. FILLED 1.315 1.137 0.13 7.47 1.260 1.700 t-1/4 1.660 1.482 O.OB 4.79 1.617 2.364 t-1/2 1.900 1.712 0.12 4.53 1.967 2.965 2 2.375 2.177 0.16 4.31 2.617 4.230 ·cmosion Resistancf' Ratio per Inst Ul Dll'Ktory listing PIPE PREPARATION BUNDLE SIZE 91 61 61 37 For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint. scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ....... --~~ For Additional Information Contact (800) 325-4467 Or From Canada Call: (800) 882-4666 1819 Clarkson Road Chesterfield, MO 63017 Gerald, MO Casa Graode, AZ www.bullmoosetube.com sales@bullrnoosetube.com DaU.,. TX Maslrt,Olt Bull Moose Tube's• Eddy Flow" is a specially engineered replacement for Schedule 10, offering better flow characteristics while providing design flexibility. This product is FM approved. as well as UL Listed (for U.S. and Canada) for roll grooving and welding. As an added benefit, it is more economical to use than Schedule 10 due to reduced delivery CDS1s and ease of handling. Furthermore, Eddy Flow's• larger ID provides an opportunity for downsizing and further cost savings. c®usLISTED <S> Al'l'RIMD ADVANTAGES OF BULL MOOSE TUBE® EDDY FLOW" • Certified to ASTM A 135 and A795 Type E, Grade A. • FM approved for roll grooving and welding for use in wet systems. • UL Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet. diy, preaction, and deluge type sprinkler systems. • Lightweight -saves shipping costs and offers easier handling. • Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. • Can be supplied roll grooved or plain end. • Can be hot dipped galvanized to meet FM's & UL requirement for diy systems. • Supplied with EDDY GUARD 11• MIC preventative coating. NPS O.D. EDDY FLOW-EDDY FLOW-WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (ID) CRR* PER FT. WT. SIZE 1-1/4 1.660 1.530 1.98 1.222 2.019 61 1-1/2 1.900 1.728 3.44 1.844 2.860 61 2 2.375 2.203 2.78 2.330 3.982 37 2-1/2 2.875 2.705 1.66 2.809 5.299 30 3 3.500 3.334 1.00 3.361 7.144 19 4 4.500 4.310 1.00 4.968 11.290 19 ·cooown Resistanc~ Ratio per latest UL DlrKtory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 Or From Canada Call: (800) 882 ·4666 1819 Clarkson Road Chesteffield, MO 63017 Gerald. MO Casa Grande. PJ. www.bullmoosetube.com salesObullmoosetube.com Dalla,. TX Masury.OH 7 Bull Moose Tube's'" Ultra Eddy-is a versatile product that can be roll grooved. welded, and used with Pressfit* Produels. a c®usLISTED ~ APl'IIMD ADVANTAGES OF BULL MOOSE TUBE'" ULTFIA EDDY" • Certified to ASTM A 135 and A795 Type E, Grade A. • FM approved for roll grooving and welding for use in wet systems. • UL listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. • Lightweight -saves shipping costs, offers easier handling. • Multidimensional: Can be used with all Schedule 5 approved roll grooved, welding and Pressfit* Products for pressures up to 175 psi. • Designed to generic Schedule 5 tolerances for easy interchangeability with all approved or listed fittings. • Can be supplied roll grooved or plain end. • Wrth a larger ID than other products on the market today, Ultra Eddy" offers substantial improvements in hydraulics. This improvement allows for downsizing within the system which offers the opportunity for additional cost savings. • Can be hot dipped galvanized to meet FM's requirement for dry systems. NPS O.D. ULTRA ULTRA EDDY" WEIGHT WATER BUNDLE (IN) (IN) EDDY" (ID) CRR** PER FT. FILLED WT. SIZE 1 1.315 1.201 2.17 .868 1.359 91 1-1/4 1.660 1.546 1.40 1.107 1.920 61 1-1/2 1.900 1.786 1.11 1.274 2.360 61 2 2.375 2.261 1.00 1.604 3.344 37 • Pressfit is a Registet'td Trademark of Vlctaulk Company of America •• Corrosion Rtsistance Ratio per latest UL Difecto,y Listing PIPE PFIEPAFIATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips. grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 Or From Canada Call: (800) 882-4666 1819 Clarksoo Road Chesterfield. MO 63017 Gerald, MO Kent.WA casa Grande.AZ www.bullmoosetube.com salesObullmoosetube.com Dallas, TX Masury.OH NPS (IN) 1 1-1/4 1-1/2 2 2-1/2 3 4 QD.(hl 1.315 1.660 1.900 2.375 IA(hl 1.201 1.546 1.786 2.261 __ _.IMI 0.868 1.107 1.274 1.604 Wllllfled_.lb'ltl 1.359 1.920 2.360 3.344 CAR. 2.17 1.40 1.11 1.00 QD.(hl 1.660 1.900 2.375 2.875 3.500 4.500 IAOn) 1.530 1.728 2.203 2.705 3.334 4.310 ----lb'ltl 1.222 1.844 2.330 2.809 3.361 4.968 j ....... fled_.(lb'ftl 2.019 2.860 3.982 5.299 7.144 11.290 C.R.R. 1.98 3.44 2.78 1.66 1.00 1.00 QD.lkl) 1.315 1.660 1.900 2.375 2.875 3.500 4.500 IAOn) 1.097 1.442 1.682 2.157 2.635 3.260 4.260 -----1.410 1.810 2.090 2.640 3.530 4.340 S.620 WIIII fled--lb'ltl 1.820 2.518 3.0S3 4.223 5.893 7.957 11.796 C.ll 15.27 9.91 7.76 6.27 4.92 3.54 2.50 QD.(hl 1.315 1.660 1.900 2.375 IAOn) 1.137 1.482 1.712 2.177 -----1.260 1.617 1.967 2.617 ,...., fled--(lb'ftl 1.700 2.364 2.965 4.230 CAR. 0.13 0.08 0.12 0.16 QD.lkl) 1.295 1.6SO 1.900 2.375 IJlOn) 1.083 1.418 1.64S 2.123 ----(lb'ftl 1.461 2.070 2.547 3.308 1PI It: fled~ lb'ltl 1.860 2.754 3.468 4.842 c®usLISTED CAR. 1.00 1.00 1.00 1.00 QD.fn) 1.315 1.660 1.900 2375 2.875 3.500 4.500 LD.On) 1.049 1.380 1.610 2.067 2.469 3.1168 4.026 <y ----(llrllll 1.680 2.270 2.720 3.660 5.800 7.580 10.800 ....... fledWlighl lb'ltl 2.055 2.918 3.602 5.114 7.875 10.713 16316 Al'l'IINID CAR. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 [i.) .~ !l!@ SJ 4'8 For Additional Information Contact (800) 325-4467 www.bullrnoosetube.com Or From Canada Call: (800) 882-4666 sales@bullrnoosetube.com 11PM ----1819 Claooon Road Chesteffield. MO Gerald, MO K,nt,WA (asa Grande, f>J. ~ TX Masury,OH ........ ,.....~~ 63017 9 NPS PIPE WEIGHT PIECES WEIGHT WEIGHT WEIGHT TYPE PER FOOT PER BUNDLE PER BUNDLE PER BUNDLE PER BUNDlE ULTIIA EDDY" 0.868 91 1,659 1,896 1,975 5CHEDUL£ 10 1.410 91 2,695 3,079 3,208 EDll¥llTE" 1.260 91 2,408 2,752 2,867 EDDmlREAD II.I" 1.461 70 2,148 2,454 2,557 SCHEDULE40 1.680 70 2,470 2,822 2,940 ULTIIAEDDY" 1.107 61 1,418 1,621 1,688 EDDl'FI.OW" 1.222 61 1,565 1,789 1,864 SCHEDULE10 1.810 61 2,319 2,650 2,760 EDDYUTr Ui17 61 2,071 2,367 2,466 EDIJffllRfAD II.I" 2.070 51 2,217 2,534 2,639 5CHEDULE40 2.270 51 2,431 2,778 2,894 ULTIIAEDDY" 1.274 61 1,632 1,865 1,943 EDDI' FLOW" 1.844 61 2,362 2,700 2,812 SCHEDULE 10 2.090 61 2,677 3,060 3,187 EDDYUTr 1.967 61 2,520 2,880 3,000 EDDl'THREAD II.I" 2.547 44 2,353 2,690 2,802 SCHEDULE40 2.720 44 2,513 2,872 2,992 ULTIIAEDDY" 1.604 37 1,246 1,424 1,484 EDDI' Fl.OW" 2.330 37 1,810 2,069 2,155 SCHEDULE 10 2.640 37 2,051 2,344 2.442 EDll¥llTE" 2.617 37 2.033 2,324 2,421 EDDl'THREAD II.I" 3.308 30 2,084 2,382 2,481 SCHEDULE40 3.660 30 2,306 2.635 2,745 c®usLISTED EDDI' FLOW" 2.809 1,770 2,022 2,107 SCHEDULE 10 3.530 30 2,224 2,542 2,648 <y SCHEDULE 40• 5.800 3,654 4,176 4,350 EDDI' Fl.OW" 3.361 1,341 1,533 1,596 Al'l'll1'llll SCHEDULE10 4.340 19 1,732 1,979 2.062 SCHEDULE 40• 7.580 3,024 3,456 3,601 m • EDDI' Fl.OW" 4.968 1,982 2,265 2,360 OMM SCHEDULE 10 5.620 19 2,242 2,563 2,670 --... _ .. ____ SCHEDULE 40• 10.800 4,309 4,925 5,130 NFPll' --,·~\/if< <s'',<-,t.-·.--. "'"".: SCHEDULE 10 9.289 10 1,951 2,229 U22 f~~ SCHEDULE 10 16.940 7 2,490 2,846 2,965 10 • Only Availablf in Casa Grande, AZ, 81JLLM 1819 Clarkson Road Chesterfield, MO 63017 PHONE: (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com sales@bullmoosetube.com c®usLISTED <f9 AfflllMD [i.) ~ MM ------ Bull Moose Tube EDDY FLOW Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load IFT'"'/ lbs. Max. Transverse and 4-way Brace Spacing (ft.)••• According to Pipe Transverse Brace Spacing• HLF for the 2006 & 2009 IBC ( ASCE 7-05) & Cp for NFPA-13 shown in BOLD TYPE Size 20 ft. 25 ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 1114 136 109 89 76 64 40 40 37 32 29 26 24 23 21 20 19 18 1112 232 185 152 130 109 40 40 40 35 31 29 27 25 23 22 21 20 2 372 297 244 209 175 40 40 40 38 34 31 28 27 25 24 23 22 2 112 549 440 360 309 258 40 40 40 40 36 32 30 28 26 25 24 23 3 809 648 531 455 381 40 40 40 40 37 34 31 29 28 26 25 24 4 1544 1235 1012 867 726 40 40 40 40 40 37 34 32 30 29 28 26 Bull Moose Tube EDDYTHREAD 40 Steel Pipe Joined by Threading, Bonding or Compraaalon/Grooved Couplings Max Zone of Influence Load (Frnoy lbs. Max. Transverse and 4-way Brace Spacing (ft.)••• According to Pipe Size 1 1 114 1112 2 Transverse Brace Spacing• HLF for the 2006 & 2009 IBC ( ASCE 7-05) & Cp for NFPA-13 shown in BOLD 20 ft. 25 ft. 30 ft. 119 95 78 218 175 143 312 250 205 518 414 339 TYPE 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 67 56 40 40 36 31 28 25 24 123 103 40 40 40 35 31 28 26 175 147 40 40 40 37 33 30 28 291 243 40 40 40 40 36 33 30 For Additional Information Contact (800) 325-4467 Or From Canada Call: (800) 882-4666 1819 Ciar1'50n Road Chesterfll!ld. MO 63017 Gerald, MO Kent.WA ca.a Grande, AZ 2.00 2.25 2.50 2.75 22 21 20 19 25 23 22 21 26 25 23 22 29 27 26 24 www.bullmoosetube.com sales@bullmoosetube.com 3.00 18 20 21 23 Dallas. TX Masury. OH 11 CAR80N STEEL PIPE HOLL CUl PRODUClS Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N V1ctaulic Mecharncal-T® Outlet provides a direct branch connection at ary location a hole can be cut in pipe. The ho!e Is cut oversize to receive a •·noIefmder" locating col!ar which secures tne outlet in pos1t1on permanently. A pressure resporsIve gasket seals on the pipe O.D. Cross.type conneclIons can be achieved by utilizing two upper hous,ngs of the same style and size, with the same or differing branch size connecl1ons. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achie11e a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. GaIvanized hous- ings are available, supplied with plated bolts. A!I sizes of Style 920 and 920N are rated at 500psi/3450kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly butylene {HDPE) pipe. Pressure ratings on HOPE are dependent on the pipe ratmg. Contact Victaul1c for ratings on other oipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard pfping practices dictate that the Mechanica!-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90¢ angle when permanently attached to the pipeline surface Additionalty, the Vic-Tap 11s hole cutting tool. which allows for hole cutting cap.abilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 V1c-Batl Valve to create the Style 931 Vic-Tap ll Mechan;cat-T unit. See page 8 for further information. STYLES 920 AND 920N 11.02 ~ : STYLE 920 CROSS PATUffED MATERIAL SPECIACATIDNS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15. Is available upon special request. JDBIDWNER System No. _________ _ locahon www.victaulic.com • Optional: Hot dipped galvanized Gasket: (Specify choice•) • Grade "E" EPDM EPDM (Green color code). Temperature range-30"F to +230~F/-34"'C lo +llOeC Recommended for cold and hot water service withir the specified temperature range plus a variety of dilute ac:ds, 01I-free air and many chemical services. UL Classified In accordance with ANSI/NSF 61 for cold +86°F/+30"'C and hot +180eF/+82°C NOT RECOMMENDED FOR PETROLEUM SERVICES • Grade "T" nitrile NItrile (Orange color code) Temperature range -20°F to +l80°F/-29°C to +8rC. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils withir the spec1f1ed temperature range. No! recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. 'Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest VictaulIc Gasket Selection Guide for spec1f1c gasket service recommendations and for a listmg of services which are riot recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meetv1g the physical anc chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. CONTRACTOR ENGINEER Submitted By ________ _ Spec Sect _____ Para ___ _ Date _____________ _ Approved Date _____________ _ v:t:fA,JLI~ IS A RLGISlllllO fRADlMAi<I< ~1( '/If IAIJLI( >1Ml-'ANV -fl 2()1 I \/ICIAIJL'i'; IDMPAN\ .0.LL fl11~HI S lL Si:.k'Jlli RF.'/ N "\/(ctauliC' ll (j2 1 CARBON STEEL PIPE • HOLE CUT PRODUCTS 11 .02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 tor Mechanical-T cross assemblies • Pressure rated up lo 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 x ½'/50 x 15mm through 8 x 4'/200 x 100mm IMPORTANT NOTES: Style 920 and Style 92ON housings cannot be mated to one another to achieve cross connections www.victaulic.com '-hie '\/111 WJ I,, A,µ Jl '-.t' ~j( Pr~~~l ::c-tll 011'le'1~ 11~ ,Vt',E,.hf ! n.tl ffoo ..c Br.mch HQle 'I t: # V f Fe-rnalf! Nominal 51ze 920 D1.:.m,e-fEr Tu Thd. Grv. W 'f Z Th<J Grv fnche"'. fJJ p,i +0.13 lnthH lnc.het lnche:; Inches lnchH lncht-:. lb':!~ lbs mm 9lON kP~ 0 O<J mm rnm m111 mm mm mm kg kg ½ (a)n 50 X 15 920N 920N ¾(a)n 20 1 (a)" 25 920"1 1 ¼(a)to 32 92JN l½(a)t::,. 40 2Y, ½(a) §a 65 X 15 920iJ 76.1 x 3 ao 31/2 90 X ¾(a) ~n 20 920fJ 1 (a) §o 25 920N I ¼tla)c 32 920tJ I ½ t (a) o 920" 40 ½ /al 15 ¾(a) 20 I (a) 25 l ¼ (a) a 32 1 •;,(a)• 40 V, (a):> 15 ¾ la)o 20 1 (a) 25 920N 920N 920N 920N 920"1 920N 920N 920"1 I \4 (aJ ta 9201~ 32 fb) l ½ (aJ t~ 920N 40(b) 2 (aj a so 2 50 920N 920N 500 3450 500 3450 500 34SO 500 3450 500 3450 500 3450 ,oo 3450 ,oo 3450 500 3450 500 3450 300 2065 300 2065 300 2065 500 3450 500 3450 500 3450 500 3450 500 3450 500 3450 500 3450 500 3450 500 3450 1.50 38.1 I.SO 38.i 150 38.1 175 445 175 ~45 150 381 1.50 381 1.50 38 1 '.75 44.5 200 508 1.50 38.l 150 38.1 1.50 38.i I 75 445 2.00 508 150 38.1 150 38.i 150 3R1 1.75 44 5 2.00 50.8 250 63 5 2.50 635 2.00 51 1.97 50 1.85 47 2.05 52 2m 52 2 . .ll 56 218 55 2.06 52 2.30 58 2.28 58 2.22 56 2.19 56 2.07 53 230 58 2.28 58 2.52 64 2.49 63 2.38 61 2.55 65 2.78 71 275 70 3.00 76 253 64 2.53 64 253 64 2.75 70 2.75 70 2.74 70 2.74 70 2.74 70 3.00 76 300 76 2.75 70 2.75 70 275 70 300 76 3.00 76 3.05 78 3.05 78 3.06 78 3.25 83 350 89 350 89 100 76 112 79 3 25 83 3 25 83 .l 3i 84 3 31 84 356 90 356 90 356 90 3 "5 95 TABLE CONTINUED ON PG. 3 1.61 41 161 41 161 41 1.61 41 1.61 ~I 1.82 46 I 82 46 182 46 182 46 1 82 46 2 25 57 2.25 57 2.25 57 1.92 49 1.92 49 2.26 58 2.28 Se 2.28 58 2.28 58 2.28 58 2.28 58 2.44 62 5 35 136 535 136 5.35 136 535 136 5.35 136 S.64 143 5.64 143 5 64 143 6.29 160 6.26 '59 646 164 6.46 164 646 164 6.29 160 6 29 160 6.15 156 6.15 156 6.15 156 6.15 156 6.15 156 6.75 '72 6.72 171 rs 70 2.75 70 2.75 70 3.00 76 3.25 83 2.75 70 2.75 70 2.75 70 3.00 76 3 25 83 318 81 3.18 81 3.18 81 300 -6 3.25 83 2.75 70 2.75 70 L.75 70 3.00 76 3 25 83 388 99 3 88 99 •• Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Avai lable with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitt,ng. # Female threaded outlets are available to NPT and BSPT spec,fications. @ See page 7 for Fire Protection approvals and pressure ratings. 3; 1 5 JI 1 5 3.0 1.4 35 1.7 16 1.7 30 14 30 14 2.9 14 3.5 1 7 3.6 I." 3.9 18 3.9 ,.a 3.8 1.7 3.5 16 35 16 3.4 16 3.4 1.6 3.3 1.6 18 1.8 4.1 1.9 4.9 2 3 (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order (b)For 76.1 mm threaded outlet, specify 2½" BSPT clearly on order. § 1/ds opproved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. 3.2 I 5 3.2 I 5 3.2 1 5 3.3 1.6 32 1.5 3.3 5 37 1.8 3.8 18 4,6 21 :; 8 1.8 VICTAULIC IS A REGIS fERED TRADEMARK OF VICTAULIC COMPANY. C 2017 I/IC fAULIC COM PAN'/. ALL RIGHTS RESERVED 11,02 2 ~ctaulic ' REV N CARBON STEEL PIPE -HOLE CUT PRODUCTS 11 .02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500psi/3450kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 x ½'/50 x 15 mm through 8 x 4'/200 x 100mm IMPORTANT NOTES: Style 920 and Style 92ON housings cannot be mated to one another to achie'/e cross connections. www.victaulic.com ' ~hlr M 11 It~,.., App0, 5:r No Prt"-,-,uit'{l 0f'1tc(~u, W1e :":hl[,h t1 Run ~ Branch Hole V + # Vt Female ~fommal S1ze 920 Ot.am~ter ,.. lhd. Grv W 'f l Thd Grv. lnchf"\ or psi +0 13 Inc.hes lnchH ltlChe~ lnctws lncht\ lnche, lb~. lbs. mm 9201' kPa -0 00 mm mm mro mm mm mm kg ~t 4 1/1 (aJ a 920N 500 100 " 15 3450 ¾ (ai a 920N 500 l') 3450 I (a1 • 920N 500 25 3450 I¼ (a)ta 920N SQQ 32 (b) 3450 I½ fa)ta 920N 500 40(b) 3450 2 (a) to 920N 500 50 3450 2½(3) t 920 500 65 3450 ~ 920 500 3450 t 920 500 0 3450 108 0 1 1/• (a1 920N 500 · " 32 3450 ~ ~ 920N soo 0 3450 2 fa) 920N 500 50 3450 76.1mm 920 50) 3450 3 (a) 920 500 ao 3450 5 1n (a) t 920 500 125 )< 40 3450 2 (a1 t 9,0 500 50 3450 2½ fa)t 920 500 65 3450 920 500 3450 3 (alt 920 500 80 3450 133.0 x 2 920!11 500 50 3450 3 920 500 80 3450 TABLE CONTINUED FROM PAGE 2 '.50 3 03 3.56 38.1 90 '.50 3.00 3.56 38.1 -6 90 I.SO 2.88 3.56 381 73 90 1.75 3.08 3.78 44.5 78 96 2.00 3.28 4.00 50.8 83 !02 2.50 3.25 400 63.5 83 !02 2.75 2.88 400 69.9 -3 102 275 2 88 69.9 73 3.50 331 4.50 88.9 84 114 1.75 3.08 3.78 44.5 78 96 2.00 3.28 400 50.3 83 l02 2.50 3.25 400 63.5 83 102 2.75 2.88 4.00 69.9 73 102 3.50 3.31 4.50 88.9 84 114 2.00 403 4.75 50.8 102 121 2.50 400 4 75 63.5 102 121 rs 363 4.75 69.9 92 121 2.75 3.~5 69.9 95 350 3.81 500 88.9 97 127 2.50 3.75 4.50 63.5 95 114 3.50 3.81 5.00 88.9 97 127 400 !02 4.00 102 4.00 102 400 102 400 102 4.12 ;o5 4.00 102 4.50 114 4.75 121 4.75 121 4.75 121 4.75 121 4.63 118 TABLE CONTINUED ON PG. 4 2.69 701 2.75 68 178 70 2.69 701 2.75 68 178 70 2.69 701 2.75 68 178 70 2.69 701 3.00 58 178 76 2.69 7.01 3.25 68 178 83 2.69 701 3.88 68 178 99 26Q 7 34 4.63 68 186 na 2.69 7 .34 4.63 68 186 118 2.69 773 5.12 68 1% 130 2.63 764 3.05 67 194 78 2.63 7.64 3.25 ':,7 194 83 2.6> 7.64 4.00 67 194 J2 2.63 7.64 4 29 67 194 109 2.63 763 4.88 67 194 124 3.16 9.70 3.69 80 246 94 3.16 9 ~o 4.38 80 246 111 316 9.-o 4.63 80 246 118 3.16 9.-o 4.63 80 246 118 3.16 9.70 5.31 80 246 135 3.17 8.00 3.88 81 203 99 3.00 9.46 5.31 "6 240 !35 •• Certer ot run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order * Certer of run to end of fitting. # Female threaded outlets are available to NPT and BSPT speofications. @Seepage 7 for F:re Protection approvals and pressure ratings. :, 7 18 3.7 18 3.6 1.8 4.0 19 4.2 20 5.0 2.3 58 26 8.4 3.8 5.0 2.3 5.0 2.3 4.0 19 8.0 3.6 6.8 3.1 7.4 34 82 3.7 8.3 3.8 8.4 3.3 8.0 3.6 8.0 36 (a) British Standard female pipe threaded outlet is a•,ailable as listed. Specify "BSPr clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services o LPCB approved for fire protection services 0 ApP'oved for use in China by Tianjin Approvals Company. 36 '.8 3.9 '.9 4.6 2 I 50 2.3 64 2.9 64 2.9 7.8 3.5 6.5 3.0 7.6 3.4 8.0 3.6 '.9 3.6 8.0 3.6 8.E 4D VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY ,0 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV N ~ctaulic· 11.02 3 CARBON STEEL PIPE • HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET • Provides a direct branch connection at any location where a hole can be cut In the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with H DPE pipe • Sizes from 2 x ½"/50 x 15 mm through 8 x 4'/200 x 100mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. www.victaulic.com Shi<" \-1 II 'fll' I,, A."1pr,H ':i1:t'-~fr Prt'\'!!>l -=~ D1 1~rh , ~ _,fr,f.ht f ,l ti Run JI Branch H'>le VS # Vt Fem&tle Nominal S11e 920 Ot~met<!r T"" Thd. Grv. W V Z Thd. Gr•1, lncht>-:. f,t p-11 +0 13 lnchu fnt;hC!S lnthe'. ln<.hu lnche1 lnthn Lb'I Lbs mm 920N kP;; 0 00 mm mm mm mm mm mrn kg_ k~ TABLE CONTINUED FROM PAGE 3 139.7 X 1 Yi t 920N 500 2.00 378 4.50 3.30 8.23 3.25 70 40 3450 50.8 96 114 84 209 83 3.2 2t 920N 500 2.S.'.l 3.75 4.50 330 823 188 9.0 so 3450 faS 95 114 84 209 99 41 6 1 V, (a) 920N 500 1.75 443 5.13 5.13 3."9 915 3 25 51 150 X 32 (b) 3450 445 112 130 130 96 232 83 2.3 I½ (a) ta 920N 500 2.00 4.40 5.13 5.13 179 9.15 3-25 5.4 40(bJ 3450 50.8 112 130 130 96 232 83 2-4 2 (a) ta 920N 500 2.50 438 5.13 5.13 379 9.15 3.88 6.0 50 3450 63.S 111 130 130 96 232 99 2.7 2 v, 920 500 2.75 4.DI 5.13 5.12 3.69 10.51 4.63 8.3 65 3450 69.9 110 130 130 94 267 '18 3.8 76.l mm o 920 500 2.75 4.15 5.21 3.69 10.51 463 3450 699 105 132 94 267 • 18 3 (a; t 920 500 3.50 4.31 5.50 5 13 3.69 IQ.SI 5.31 9.9 80 3450 88.9 110 140 130 94 267 135 45 4 (ai to 920 500 4.50 3.81 5.75 5.38 169 10.51 6.25 10.1 100 3450 114.3 97 146 137 94 267 159 46 159.0 X I½ (a) 920N 500 2.00 4.41 5.13 j63 940 3.25 7.8 40 3450 508 112 130 92 239 83 3.5 2 (ai 920N 500 2.50 4.33 5.13 363 9.40 188 8.0 so 3450 63.S l'I 130 92 239 99 36 76.1 mm 920 500 275 4.38 ,.so 5.13 3.63 9.40 4.63 9.5 3450 69.9 Iii 140 130 92 239 118 4.3 3 920 <oo 3 50 4 31 5.50 5.13 3.63 9.40 531 8.1 80 3450 88.9 110 HO 130 92 239 135 3.7 108.0mm 9:0 '00 4.50 4.45 538 3.63 9.40 6.12 3450 114.3 113 137 92 239 i55 4 920 $00 450 3.81 5.75 363 9.40 6.25 18.0 100 3450 114.3 96.80 146 92 239 159 8.2 TABLE CONTINUED ON PG. 5 • • Center of run to engaged pipe end. female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet Specify choice on order. * Center of run to end of fitt ng. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Srandard feMale pipe threaded outlet is available as listed. Specify "BSPT" clea, ly on order. (b)For 76.l mm threaded outlet, specify 21/i BSPT clearly on order. § Vds approved for fire protection services a LPCB approved for fiie protection se•vices 0 Approved for use in Chir,a by Tianjin Approvals Company. 4.8 2.2 5.1 2.3 5.6 2.5 76 3.4 8.4 3.8 84 3.8 i1J.I 4.6 9.5 4.3 14.0 6.4 10.0 45 VICTAULIC IS A REGISTERED TRADEMARK OF VIC fAUUC COMPANY. C 2017 1/ICTAULIC COMPANY ALL RIGHTS RESERVED 11.02 4 ~ctaulid REV N CARBON STEEL PIPE -HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS GROOVED OUTlET FEMALE THREADED OUTLET • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500psi/3450kPa on steel pipe; also available for use with HDPE pipe • Sizes from 2 x ½'/50 x 15mm through 8 x 4"/200 x 100mm IMPORTANT NOTES: Style 920 and Styie 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com 'hlr \! 11 f.i, r.,_ Ap1 rt'l '::>:t' N0 P1",,u1t"{' i"111t:f)Lr, Wtth!fnt1 Rut\ .t Branch Hole V t # V f female ffom1n..t Size: 920 01.tm~ter l "~ Thd. GrY VI Y Z Thd, Grv lnch,:i Qt f)fil +O l 3 Inches lnche, lnche~ Im.hes lnche-:. lncht:t Lt,') lbt.. mm q20N kPa -0 00 rnm mm mm mm mm mm k?. J,;g TABLE CONTINUED FROM PAGE 4 165.! 1 920!~ 500 1.50 388 4.56 379 934 2.75 8.0 X i5 3450 381 99 I 16 96 237 70 3.6 J¼:J 920N 500 1.75 4.43 5.13 3.79 9.34 3;5 8.4 32 3450 44 5 113 130 96 237 83 3.8 1 ½ (a)to 920N 500 2.0IJ 4.41 5.13 5.-3 3.79 934 3 ;s 8.4 5.4 40 3451) 50.8 112 130 130 96 237 83 3.8 2.4 2 (a) t 920N 500 2 50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 so 3450 63.5 111 130 130 96 237 99 3.9 2.7 76.1mm 920 500 275 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 3450 69.9 110 130 132 92 267 118 3.9 3.4 3(a)t0 920 500 3.50 4.31 5.50 5.13 3.63 10.51 5.31 10.2 8.4 80 3450 889 110 140 130 92 267 135 4.6 38 4 (a) ta 920 500 4 so 3.81 5.75 S 38 3.63 10 5' 625 105 84 100 3450 !14 3 97 146 137 92 267 159 4.8 38 8 X 2(alt 920 500 2.75 5.44 619 6.25 481 1242 4.50 11.6 11.6 200 so 3450 69.9 !38 157 159 122 316 114 5.3 5.3 2½ (a) t 920 500 2 '5 5.07 6.19 6.19 481 1242 4.50 11.6 11.6 65 3450 69.9 129 157 157 122 :;15 114 s.:; 5.3 76.1 mm ~ 920 500 2.75 5.25 6.25 4.8' 12.42 456 11.6 3450 69.9 133 159 122 316 116 5.3 3 (a) to 920 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6 80 3450 88.9 i35 165 165 122 316 135 5.7 5.3 4 (a) tc 920 500 4.50 4.8" 6.75 6.38 4.81 1242 6.25 ,5.3 12.5 JOO 3450 114.3 122 171 162 122 316 159 o.9 5.7 •• Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Mailable with grooved or female threaded outlet. Specify choice on order. * Cel"ter of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fir~ Protection approvals and pressure ratings.· (a) British Standard female pipe threaded ot.tlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 211{ BSPT clearly on order. § Vds approved for fire protection ser,;ices o LPCB approved for fire protection services 0 Appro'1ed for use in Cnina by Tlan;in Approvals Company. VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY 10 2017 VIC fAULIC COMPANY. ALL RIGHTS RESERVED REV N ~taulid 1L02 S CARBON STEEL PIPE HOLE CUT PRODUCTS 11 .02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-T1> fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. @ Cv and Kv Values I Values for flow of water at +6Q°F/+l6°C are shown in the table below. Formulas for Cv 11<., Values: Where: Q = Flow (GPM) LIP = Q' C,' Q = C, X Jii LIP = Pressure Drop (psi) C, = Flow Coefficient Exaggerated lo, clarrry ¾ 20 26 7 1 1.315 3 . 25 33.7 1¼ 1660 32 42.7 5 ½ iVi 1.900 40 98.7 i1 2 2.375 so 51) 3 9 2½ 2.875 65 73.0 20 76.1 mm 3.000 76.1 10· 3 3.500 80 889 14 4 4.500 100 114.3 20 ! Hazen-Williams coefficient of friction Is 120. • Pipe with a wall thickness of 0.165in/4.2mm. •• 1 • Firelock'" lnnovanve Groove System (IGSJ outlet www.victaulic.com VICTAULIC JS A REGISTERED rRADEMARK OF VICTAULIC COMPANY. C 20l7 1/ICTAULIC COMPANY. ALL RIGHTS RESERVED 11.02 6 4 8 6 ,, 10 1/1 12 Vi IS ½ 2L LIP= Q' Q =K,xJii 50 42.9 53 45.4 112 96 119 \02 151 138 I 249 213.4 421 3608 Where: Q = Flow (m'/hr) LIP = Pressure Drop (Bar) K, = Flow Coefficient 16 13.7 21 1.8 48 41 I 53 454 104 89.1 150 128.5 237 203.1 401 343.6 ~ctaulid REV N CARBON STEEL PIPE · HOLE CUT PRODUCTS 11 .02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or add1t1ons by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. I\ '\H<'~ ti ili.~t l , , Ru 1 "> ., l1u11, t S :,• p j't' 1-l ik,' Work1ni: fl,,,, ir, " 1,.,JI At:.tuaf Ncrnm.al Ouhtd~ 'ldt S11e 01-!mtter lnche'1'1nrn tnche--,/mm Inc.ho/mm Schedule UL IJLC FM LPCB (Sit!• 920) (Styl• 920N) 21/2 -6 2.875 -6.625 All 10,40 400 400 400 290 232 362 65-150 73.0 168.3 2755 2755 2755 1999 1599 2496 21/2-4 2875 -4.500 All DF 300 300 300 290 232 362 65-100 73.0-1143 2065 2065 2065 1999 1599 2496 21/2-4 2.875 -4.500 All SF 300 301) 300 290 232 362 65-100 730-114.3 2065 2065 2065 1999 1599 2496 6 6.625 3, 4 10 300 300 250 290 232 362 150 168.3 2065 2065 1724 1999 1599 2496 -6 6.625 3,4 30, 40 300 300 300 290 232 362 150 1683 2065 2065 2065 1999 1599 2496 8 8.625 21/2 10,40 400 ---145 -200 219.1 2755 !000 8 8.625 3.4 10 300 -250 -145 -200 2191 2065 1724 1000 8 8.625 3,4 30, 40 300 -301) -145 -:IOO 219.1 2065 2065 1000 NOTES: 10 refers ro Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR 4 · 8"/100 · 200 MM CARBON STEEL PIPE www.victaulic.com The Vic-Tap II hole cutting tool Is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500psi/345OkPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 4'/lOOmm, 5'/125mm, 6'/15Omm and 8'/200 mm diameter pipe. The Style 931 comes with a 2 ½'/65mm grooved outlet. The drill motor Is an electric motor with ground fault circuit interrupter (GFCI) in accordance with safety codes. For more information. refer to publication 24.01. VICTAIJL!C IS A REGISTERED TRADEMARK Of VICTAULIC COMPANY «:l 2017 VICTAUL!C COMPANY ALL RIGHTS RESERVED. REV N ~aulir:! 11.02 7 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N INSTALLATION WARRANTY NOTE Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Viclaulic or lo Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com ~t.aulic" 11.02 1480 REV N UPDATED 12/2017 'IICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY C 2017 'IICTAULIC COMPANY ALL RIGHTS RESERVED 11.02 L STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, ¾, and 1 "/15, 20 and 25 mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Availa ble for l¼ through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. JOB/OWNER System No. __________ _ Location ____________ _ www.victaulic.com Gasket: • Grade "E" EPDM -Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: • Orange enamel (North America, Latin America, Asia Pacific) • Red enamel (Europe) CONTRACTOR ENGINEER Submitted By ________ _ Spec Sect _____ Para ___ _ Date _____________ _ Approved Date _____________ _ VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. <0 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV G "\.k=tauliC' 10.52 1 IPS CARBON STEEL PIPE · HOLE CUT PRODUCTS 10.52 Firelock® Outlet-T STYLE 922 DIMENSIONS I www.victaulic.com Nonunal S11e I Hole I I Approx inches/mm Diameter D1mens1ons 1nches/m1ll1meters Weight Each Run X Br-1nch +-0 06/+l 5 FPTI 0 00/ 0.0 r· V w y l lb>/~g 1¼ X ½ P/16 1.30 1.83 1.10 3.87 2.56 1.0 32 15 30.2 33.0 46.S 27.9 98.3 65.0 0.45 ---¾ 13/i6 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 32.S 46.S 27.9 98.3 65.0 a.so -1 13/16 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 1½ X ½ 11/16 1.42 1.95 1.22 408 2.56 1.2 40 15 30.2 36.1 49.S 31.0 103.6 65.0 0.54 ¾ 13/16 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.S 31.0 103.6 65.0 0.54 1 13/16 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 65.0 0.59 2 X ½ 11/16 1.66 2.19 1.46 4.60 2.56 1.3 50 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59 ¾ P/i6 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 11/,6 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 0.68 2½ X ½ PA6 1.91 2.44 1.71 5.40 2.56 1.6 65 15 30.2 48.S 62.0 43.4 137.2 65.0 0.73 ¾ 11/i6 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1 P/i6 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 76.1 mm X ½ l3/i6 1.91 2.44 1.71 5.50 2.56 1.6 15 30.2 48.S 62.0 43.4 139.7 65.0 0.73 ¾ 13/i6 1.89 2.44 1.71 5.50 2.56 1.6 20 30.2 48.0 62.0 43.4 139.7 65.0 0.73 1 ]3/i6 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads (dimensions are approximate). VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. C 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10,52 2 ~taulic' REV G IPS CARBON STEEL PIPE • HOLE CUT PRODUCTS Firelock® Outlet-T STYLE 922 PERFORMANCE www.victaulic.com Run Size x Outlet Size 213 Section 16) {C=120) FT I Equ1v,1lent Length of I mch Schedule 40 Steel Pipe (per UL [ lnch•s/mm Fee!Jm•t•r> - 1¼ X I 8.5 32 25 2.6 -I½ X I 8.5 40 25 2.6 -2 X I 8.5 50 25 2.6 -2½ X I 8.5 65 25 2.6 - 76.1 mm X 1 8.5 25 2.6 • Hazen-Williams coefficient of friction is 120 VICTAUUC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.© 2009 VICTAUUC COMPANY. ALL RIGHTS RESERVED. REV G 10.52 ~taulic' 10.52 3 STYLE 922 INSTALLATION WARRANTY NOTE Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com ~taulid 10.52 3355 REV G UPDATED 12/2009 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. C> 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.52 Ductile Iron Threaded Fittings INTERNATIONAL Ductile Iron Threaded Fittings Specifications • <©> branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 WSP • Ductile iron castings conform to ASTM A536 • Fitting dimensions conform to ASME 816.3 • Bushings and plugs conform to ASME 816.14 • Fittings are 100% air tested • NPT threads on all fittings conform to ASME B 1.20.1 c@us LISTED ~ APPROVED • Independent lab verification that fittings meet applicable chemical & physical properties • Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Degrees F Working Pressure, Nonshock psiG 300# Class Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 ,- 400 400 450 380 -500 360 550 340 ... 600 320 650 300 c®us ~ Fig. 35£ 3 -99° Elbow LISTED Size Part Number A Weight in in r lb 1/2 35E 3004 1.13 200 0.2 3/4 35E 3006 1.31 140 0.3 35E 3010 1.50 40 80 0.5 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3 -99° Redacing Elbow B Size Part Number A B Pacldna Weight in in in Inner M .. ,., lb 3/4 X 1/2 35RE3006004 1.20 1.22 80 160 0.3 1 X 1/2 35RE3010004 1.26 1.36 70 140 04 ,--1 X 3/4 35RE3010006 1.38 1.45 50 100 0.4 1-1/4 X 1/2 35RE3012004 1.34 ,_ 1.53 -70 0.5 35 ,~ -1-1/4 X 3/4 35RE3012006 1.45 1.63 35 70 0.6 _,_ 1-1/4 X 1 ,_35AE3012010 1.58 1.67 30 60 1-0.7 -,- 1-1/2 X 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2 X 3/4 35RE3014006 1.52 -r-1.75 ~ 25 50 07 -,--1-1/2x1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2 X 1-1/4 35RE3014012 I• 1.82 -'" 1.88 18 ~6 1.0 -,-2 X 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x3/4 35RE3020006 1.60 -,_ 1.97 18 -26 1.0 _,_ -2x1 35RE3020010 1.73 2.02 16 32 1.2 --2x1-1/4 35AE3020012 1.90 2.10 12 24 1 3 -2x1-1/2 35RE3020014 2.02 2.16 10 20 1.5 -2-1 /2 X 1-1/2 35AE3024014 2.16 2.51 6 1L. 2.2 -2-1/2x2 35RE3024020 2.39 2.60 6 12 2.5 Fig. 35F 3 -45° Elbow Size Part Number A Pacldn Weight in in Inner Master lb 1/2 35F 3004 0.88 150 300 0.2 3/4 35F 3006 0.98 80 160 0.3 35F 3010 1.13 80 0.5 IA 35F 3012 1.29 50 0.7 1-1/2 35F 3014 1.44 20 40 1.0 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3 -Tee Size Part Number A Weight ffiJ A in in lb 1/2 35T 3004 1.13 160 0.3 3/4 35T 3006 1.31 60 0.5 1 35T 3010 1.50 25 50 0.7 1-1/4 35T 3012 1.75 10 20 1 1 ~· ~ 1-1/2 35T 3014 1.94 10 20 1.5 2 35T3020 2.25 6 12 24 2-1/2 35T 3024 2.70 4 8 4.3 111 S\IJTH-COOPER l'.\:TER:-.:r\TIOi'\:-\L'• • TOLL FREE l-8{1().766-007o • Fr\X (.,Z.\) 890-4456 • www.smirhwopcr.com c®us <§> APPROIIED Fig. 3SRT3 -Reducing Tee LISTED Size Part Number A a C Weight in in in in lb 3/4 X 1/2 35RT3006004 1.20 1.20 1.22 04 1 X 1/2 35RT3010004 1 26 1 26 1 36 30 0.6 1 X 1/2 X 1 35RT3010004010 1.50 1.36 1.50 30 60 06 1 X 3/4 35RT3010006 1.38 1.38 1 45 25 50 06 --1-1 X 3/4 X 3/4 35RT3010006006 1.38 1.31 1.45 35 70 0.6 B A 1 X 3/4 X 1 35RT3010006010 1.50 1 45 1 50 25 50 07 1-1/4 X 1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4 X 1/2 X 1-1/4 35RT3012004012 1.75 1.53 1.75 25 50 09 1-1/4x3/4 35RT3012006 1.45 1.45 1.62 15 30 09 1-1/4 X 3/4 X 1-1/4 35RT3012006012 1.75 1.62 175 20 40 1.0 1-1/4 X 1 35RT3012010 1.58 1.58 1.67 15 30 1.0 1-1/4X 1 X 1/2 35RT3012010004 1.34 1.26 1 53 25 50 07 1-1/4 X 1 X 3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1/4x1x1 35RT3012010010 1 58 1 50 1 69 20 40 0.9 1-1/4 X 1 X 1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1 0 1-1/2 X 1/2 35RT3014004 1 41 1.41 166 16 32 1.0 1-1/2 X 1/2 X 1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1/2 X 1/2 X 1-1/2 35RT3014004014 194 1 66 194 12 24 1 2 1-1/2 x 3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1/2 X 3/4 X 1-1/4 35RT3014006012 1.94 1 66 1.88 20 40 1.1 1-1/2X3/4 X 1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1 2 1-1/2 X 1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1-1/2 X 1 X 1/2 35RT3014010004 1.44 1.25 1.69 20 40 08 1-1/2 X 1 X 3/4 35RT3014010006 1.50 1 44 1.75 16 32 0.9 1-1/2x 1 X 1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 1-1/2 X 1 X 1-1/4 35RT3014010012 1 82 1 67 1.88 12 24 1.2 1-1/2 X 1 X 1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1 3 1-1/2x1-1/4 35RT3014012 1.82 1.82 1.88 12 24 1.4 1-1/2 X 1-1/4 X 1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 1-1/2 X 1-1/4 X 3/4 35RT3014012006 1.52 1 45 1.75 16 32 1.0 1-1/2 X 1-1/4 X 1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 1-1/2 X 1-1/4 X 1-1/4 35RT3014012012 1 82 1 75 1 88 14 28 1.3 1-1/2 X 1-1/4 X 1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 2 X 1/2 35RT3020004 1.49 1.49 1.88 10 20 1.5 2 X 3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 2x1 35RT3020010 1.73 1.73 2.02 8 16 1 7 2x1x2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 2 X 1-1/4 35RT3020012 190 190 2.10 8 16 1.9 2 X 1-1/4 X 2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2x1-1/2 202 2.02 2.16 8 16 21 2 X 1-1/2 X 1/2 35RT3020014004 1.49 1.41 1 88 10 20 1.3 2x 1-1/2x3/4 35RT3020014006 1.60 1.52 1.97 10 20 1 4 2x1-1/2x1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2x 1-1/2x 1-1/4 35RT3020014012 190 1.82 2.10 8 16 1.7 2 X 1-1/2 X 1-1/2 35RT3020014014 2.02 1.94 2.16 8 16 1.8 Fig. 3SBT3 -Bull Head Tee Size Part Number A a C Pacldna Weight in in in in lnn•r --. lb 3/4 X 1 35BT3006010 1.45 1.45 1.37 30 60 0.6 1 X 1-1/4 ,_35BT3010012 I-1 67 1.67 1.58 20 40 09 1x1-1/2 35BT3010014 1.80 1.80 1.65 15 30 1.0 1-1/4X1 X 1-1/2 358T3012010014 1.88 1 80 1 82 15 30 1.2 l-1/4x1-1/2 35BT3012014 1.88 1.88 1.82 15 30 1.3 1-1/4x2 35BT3012020 2.10 2.10 1.90 10 20 1 6 1-1/2 X 1-1/4 X 2 35BT3014012020 2.16 2.10 2.02 10 20 1.8 1-1/2 X 2 35BT3014020 2.16 2.16 202 8 16 1.8 S~IIT II-COOPF.R INTF.R:--;ATIO~AU' • TOLL FRF.F. J-800-7oo-007o • FAX (.,23) 89<l-+J56 • www.smirhcoopcr.com 112 c@us ~ Fig. 3SCP3 -Straight Coupling with Ribs LISTED Size Part Number A Packlna Weight in in Inner Master lb 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 ,--,-,--1 35CP3010 1.75 60 120 0.4 ----1-1/4 35CP3012 2.00 35 70 0.5 ,_ --1-1/2 35CP3014 2.19 25 50 0.7 -_, __ -2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 Fig. 3SRC3 -Hex Reducing Coupling Size Part Number A Packlna Weight in in Inner Master lb 1 X 1/2 35RC3010004 1.69 80 160 0.3 1 X 3/4 35RC3010006 1.69 60 120 04 ---,--,--1-1/4 X 3/4 35RC3012006 2.06 40 80 0.6 2 x 1 (not hex) 35RC3020010 2.81 20 40 1.0 Fig. 3SRB3 -Hex Bushing Size Part Number A Weight mA in in lb 1 X 1/2 35HB3010004 1.06 180 0.2 1 X 3/4 35HB3010006 1.06 180 0.1 1-1/4 X 1 35HB3012010 1.19 90 180 0.2 1-1/2x1 35HB3014010 1.25 75 150 0.4 1-1/2 X 1-1/4 35HB3014012 1.25 75 150 0.3 35HB3020010 1.38 40 80 0.6 35HB3020012 1.38 40 80 0.6 35HB3020014 1.38 40 80 0.6 Fig. 3SSP3 -Square Head l'lug Size Part Number A Packin Weight in in Inner lb ~A 1/2 35SP3004 0.94 600 1200 0.07 35SP3006 1.12 350 700 0.1 1 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 0.4 2 35SP3020 1.50 45 0.6 Fig. 3Sll 3 -llnion with Brass Seat A Size Part Number A Weight .!Jj. in in r lb 1 35U 3010 2.19 40 1.0 1-1/4 35U 3012 2.50 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 2 35U 3020 3.12 6 12 2.4 113 S\IIT J-1-COOPER I'.\:TERNA'TIO'.\:,\L~ • TOLL F REE 1-800-766-0076 • FAX (.,Z.,) 890-4--l56 • www.smirhcoopcr.com c®us~ Fif. 35X 3 -Cross LISTED Size Part Number A Packina Weight in in Inner Master lb 1 35X 3010 1.50 20 40 0.9 1-1/4 35X 3012 1.75 12 24 1 4 ,--,----1-1/2 35X 3014 1.94 8 16 1.8 2 35X 3020 2.25 6 12 2.8 Fif. 35BX3 -Redacinf Cross Size Part Number A B Packina Waight in in in Inner Master lb 1-1/4 X 1 35RX3012010 1.67 1.58 15 30 1.2 1-1/2 X 1 35RX3014010 1.80 1.65 12 24 1.4 --2x1 35RX3020010 202 1.73 8 16 2.0 Fif. 35C 3 -Cap Size Part Number A Packina Weight in in Inner Master lb 1/2 35C 3004 0.87 300 600 0.1 3/4 35C 3006 -0.97 200 400 0.1 --,_ --1 35C 3010 1.16 110 220 0.2 1-1/4 35C 3012 ,_ 1.28 ,_ _,_ ----70 140 ~4 _,_ _,_ -1-1/2 35C 3014 1.33 50 100 0.5 35C 3020 ,~ ,_ -,~ -2 1 45 25 50 0.8 2-1/2 35C 3024 1.70 18 36 1 6 Fif. 35BC3 -Beam Clamp Size Part Number A Packina Weight in in Inner Master lb 3/8 35BC3003 0.75 100 200 0.3 C. 1/2 35BC3004 0.75 80 160 0.5 S\IIT I I-COOPER INTER'.\:ATIONAL" • TOLL FREE J-800-7on-0076 • F X (3.23) 890-~56 • www.smi1hcoopcr.com 114 Mee t1c1n1cdl Anc l1onnq Systen1s KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3. 7 3.3. 7 .1 Product description KWIK HUS-EZ I {KH-EZ I) anchors are comprised of a body with an internally threaded hex washer head. The anchor is manufactured from carbon steel and is heat treated. It has a minimum 0.0003 inch (8 µm) zinc coating in accordance with DIN EN ISO 4042. The internally threaded head is larger than the diameter of the anchor and is formed with serrations on the underside. The anchor body is formed with threads running most of the length of the anchor body. The anchor is installed in a predrilled hole with a powered impact wrench or torque wrench. The anchor threads cut into the concrete on the sides of the hole and interlock with the base material during installation. Applicable base materials include normal-weight concrete, structural lightweight concrete and lightweight concrete over metal deck. Guide specifications Screw anchors shall be KWIK HUS-EZ I as supplied by Hilti, Inc. Anchors shall be manufactured from heat treated carbon steel material, zinc plated to a minimum thickness of 8 µm. Anchors shall be installed using a drill bit of same nominal diameter as anchor. Product features • Suitable for cracked and uncracked normal-weight and lightweight concrete, and lightweight concrete over metal deck. • Suitable for seismic and nonseismic loads. • Quick and easy to install. • Thread design enables quality setting and exceptional load values in wide variety of base material strengths. • Anchor is fully removable • Anchor size is same as drill bit size. • Suitable for reduced edge distances and spacing. 3.3. 7 .2 Material specifications KWIK HUS-EZ I anchors are manufactured from carbon steel. The anchors are bright zinc plated to a minimum thickness of 8 µm. 3.3. 7 .3 Technical data 3.3.7.3.1 ACI 318-14 Chapter 17 design The technical data contained in this section are Hilti Simplified Design Tables. The load values were developed using the design parameters and variables of ESR-3027 and the equations of ACI 318-14 Chapter 17. For a detailed explanation of the Hilti Simplified Design Tables, refer to section 3.1.8. Data tables from ESR- 3027 are not contained in this section, but can be found at www.icc-es.org or at www.us.hilti.com. 3.3.7.1 Product description 3.3.7.2 Material specifications 3.3.7.3 Technical data 3.3.7.4 Installation instructions 3.3.7.5 Design guidelines 3.3.7.6 Ordering information Listings/ Approvals ICC-ES (International Code Council) ESR-3027 City of Los Angeles Research Report No. 25897 FM (Factory Mutual) Pipe Hanger Components for Automatic Sprinkler Systems for 3/8 internal threaded diameter anchor Independent code evaluation IBC® / IRC®2015 IBC® / IRC® 2012 IBC® / IRC® 2009 IBC® / IRC® 2006 II Hilti, Inc. (US) 1-800-879-8000 I www.us.hilti.com I en espaiiol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2016 319 Mee llc1111c c1I Anchoring Systen1s 3.3. 7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 1 -Hilti KWIK HUS-EZ I specifications1•2 Nominal anchor Figure 1 -KWIK HUS-EZ I anchor installation details Setting diameter information Symbol Units 1/4 Nominal bit diameter do;, in. 1/4 -wrench size Nominal embedment hnom in. 1-5/8 2-1 /2 Effective embedment h., in. 1.18 1.92 Minimum hole depth ho in. 2 2-7/8 ft-lb 18 Installation torque Tlnst (Nm) (24) Wrench size in. 7/16 1 T ~ .. is the maximum installation torque that may be applied with a torque wrench. 2 See table 2 and figure 5 of section 3.3.6 for spacing, edge distance, and concrete thickness pa- rameters Table 2 -Hilti KWIK HUS-EZ I design strength with concrete/ pullout failure in uncracked concrete1.2,3,4,5 Nominal Nominal Tension -q,Nn Shear -<!>Vn anchor embed. f "0 = 2,500 psi f'0 = 3,000 psi f'c = 4,000 psi !'0 = 6,000 psi f 'c = 2,500 psi f "0 = 3,000 psi f "0 = 4,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) in. in.(mm) lb (kN) lb(kN) lb (kN) lb(kN) lb(kN) lb(kN) lb (kN) 1-5/8 585 620 675 765 1,075 1,180 1,360 1/4 (41) (2.6) (2.8) (3.0) (3.4) (4.8) (5.2) (6.0) 2-1/2 1,525 1,670 1,930 2,365 2,235 2,450 2,825 (64) (6.8) (7.4) (8.6) (10.5) (9.9) (10.9) (12.6) Table 3 -Hilti KWIK HUS-EZ I design strength with concrete/ pullout failure in cracked concrete1.2,3,4,5 Nominal Nominal Tension -<t>N" Shear -<!>Vn anchor embed. f 'c = 2,500 psi f'c = 3,000 psi f'c = 4,000 psi f 'c = 6,000 psi f 'c = 2,500 psi f'c = 3,000 psi f'c = 4,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) in. in.(mm) lb(kN) lb (kN) lb(kN) lb(kN) lb(kN) lb (kN) lb (kN) 1-5/8 300 315 345 390 765 835 965 1/4 (41) (1.3) (1.4) (1 .5) (1.7) (3.4) (3.7) (4.3) 2-1/2 760 830 960 1,175 1,585 1,735 2,000 (64) (3.4) (3.7) (4.3) (5.2) (7.1) (7.7) (8.9) See section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Apply spacing, edge distance, and concrete thickness factors in tables 5 and 6 as necessary. Compare to the steel values in table 4. The lesser of the values is to be used for the design. 4 Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by>-., as follows: for sand-lightweight, >-., = 0.68; for all-lightweight, >-., = 0.60 f '0 = 6,000 psi (41.4MPa) lb (kN) 1,670 (7.4) 3,460 (1 5.4) f'c = 6,000 psi (41.4MPa) lb (kN) 1,180 (5.2) 2,450 (10.9) 5 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic tension loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth -a,.,...,= 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth -aN ..... = 0.75 No reduction needed for seismic shear. See Section 3.1.8.7 for additional information on seismic applications. Table 4 -Steel design strength for Hilti KWIK HUS-EZ I anchors1•2 Nominal anchor Nominal internal Tensile3 diameter thread diameter <!>N .. in. in. lb (kN) 1/4-20 3,680 1/4 UNC (16.4) 3/8-16 3,680 UNC (16.4) See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I anchors are to be considered brittle steel elements. 3 Tension <1>N., = <1>A,.,Nf,., as noted in ACI 318-14 Chapter 17. Shear" <1>V .. lb(kN) 815 (3.6) 790 (3.5) 4 Shear determined by static tests with <1>V., < 0.6<1>A.,,v f,., as noted inACI 318-14 Chapter 17. Seismic shear5 <1>V •• lb (kN) 365 (1.6) 670 (3.0) 5 Seismic shear values determined by seismic shear tests with <1>V,. s <I> 0.60 A,.,v f""' as noted in ACI 318-14 Chapter 17. See Section 3.1.8.7 for additional information on seismic applications. 320 Hilti, Inc. (US) 1-800-879-8000 I www.us.hilti.com I en espaiiol 1 ·800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2016 Mechanical Ar1chonng Syste,ns KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3. 7 Table 5 -Load adjustment factors for 1/4-in. diameter Hilti KWIK HUS-EZ I in uncracked concrete1•2 Edge distance in shear Spacing factor Edge distance Spacing factor II to and away Cone. thickness 1/4-in. KH-EZ in tension factor in tension in shear" 1-toward edge from edge factor in shear4 uncracked concrete f AN f RN f AV f RV f RV f HV Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 hnom (mm) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.78 0.65 0.59 0.56 0.40 0.21 0.78 0.42 n/a n/a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 0.61 0.33 1.00 0.65 n/a n/a Q) ~ 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.86 0.46 0.90 n/a n/a u 3 (76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a C 0 3-1/4 (83) 0.96 0.78 0.70 0.63 0.68 0.88 n/a u ---3-1/2 (89) 0.99 0.80 0.71 0.64 0.76 0.92 n/a -.E -2-.s 4 (1 02) 1.00 0.85 0.74 0.66 0.92 0.98 n/a Q) u C: 4-1/8 (105) 0.86 0.75 0.66 0.97 1.00 0.81 C ·-4-1/2 (114) 0.89 0.77 0.68 1.00 0.84 Cll ~£ 5 (127) 0.93 0.80 0.70 0.89 Q) gi 5-1/2 (140) 0.98 0.83 0.72 0.93 0) Q) 6 (152) 1.00 0.86 0.74 0.97 tl C Q) ~ 7 (178) 0.92 0.78 1.00 -....S:2 -.s::: -!!!,+-8 (203) 0.98 0.82 0) 9 (229) 1.00 0.86 C ·u 10 (254) 0.89 Cll Cl. 11 (279) 0.93 (/) 12 (305) 0.97 14 (356) 1.00 Table 6 -Load adjustment factors for 1/4-in. diameter Hilti KWIK HUS-EZ I in cracked concrete1.2 m Edge distance in shear Spacing factor Edge distance Spacing factor II to and away Cone. thickness 1/4-in. KH-EZ in tension factor in tension in shear" .l toward edge from edge factor in shear4 cracked concrete f AN f RN f AV f RV f RV f HV Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 hnom (mm) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.88 0.65 0.59 0.56 0.40 0.21 0.80 0.43 n/a n/a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 0.62 0.33 1.00 0.66 n/a n/a (I) 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.87 0.46 0.90 n/a n/a ~ 3 (76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a u 3-1/4 (83) 0.96 0.78 0.70 0.63 0.68 0.89 n/a C 0 0.92 n/a u 3-1/2 (89) 0.99 0.80 0.71 0.64 0.76 ------. E 4 (102) 1.00 0.85 0.74 0.66 0.93 0.98 n/a &E (105) 0.86 0.66 0.97 1.00 0.81 (I)~ 4-1/8 0.75 U C 0.85 C ·-4-1/2 (114) 0.89 0.77 0.68 1.00 "' ~£ 5 (127) 0.93 0.80 0.70 0.89 (I) ill 5-1/2 (140) 0.98 0.83 0.72 0.93 O> (I) TI C 6 (152) 1.00 0.86 0.74 0.98 (I)-"' ......... 2 7 (178) 0.92 0.78 1.00 -.c .!!!, -8 (203) 0.98 0.82 Cl C 9 (229) 1.00 0.86 ·u "' 10 (254) 0.90 a. (/) 11 (279) 0.94 12 (305) 0.98 14 (356) 1.00 1 Linear interpolation not permitted. 2 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using design equations from ACI 318-14 Chapter 17. 3 Spacing factor reduction in shear, f AV' assumes an influence of a nearby edge. If no edge exists, then f Av = f AN" 4 Concrete thickness reduction factor in shear, f HV' assumes an influence of a nearby edge. If no edge exists, then f HV = 1.0. c=:::J If a reduction factor value is in a shaded cell, this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa). Check with table 5 and figure 2 of section 3.3.6 to calculate permissable edge distance, spacing and concrete thickness combinations. Hilti, Inc. (US) 1-800-879-8000 I www.us.hilti.com I en espariol 1-800-879-5000 I Hilti (Canada} Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2016 321 Mecllc1nic al Anchoring Systerns 3.3. 7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 7 -Hilti KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck1•2•3•4•5•6•7 Installation in lower flute Installation in upper flute Nominal Tension -4>N0 Shear -cpV0 Tension -4>N0 Shear -4>V0 Nominal internal Nominal anchor thread embed. f 'c = 3,000 psi f'c = 4,000 psi 1/'c = 3,000 psi 1/'c = 4,000 psi f 'c = 3,000 psi f'c = 4,000 psi f'c = 3,000 psi V'c = 4,ooo psi diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in.(mm) lb (kN) lb(kN) lb (kN) lb (kN) lb (kN) lb(kN) lb (kN) lb (kN) 1-5/8 545 595 610 610 670 730 610 610 1/4-20 (41) (2.4) (2.6) (2.7) (2.7) (3.0) (3.2) (2.7) (2.7) UNC 2-1/2 1,220 1,410 610 610 1,275 1,470 610 610 (64) (5.4) (6.3) (2.7) (2.7) (5.7) (6.5) (2.7) (2.7) 1/4 1-5/8 545 595 915 915 670 730 915 915 3/8-16 (41) (2.4) (2.6) (4.1) (4.1) (3.0) (3.2) (4.1) (4.1) UNC 2-1/2 1,220 1,410 915 915 1,275 1,470 915 915 (64) (5.4) (6.3) (4.1) (4.1) (5.7) (6.5) (4.1) (4.1) Table 8 -Hilti KWIK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck1·2·3·4·5·6·7·8 Installation in lower flute Installation in upper flute Nominal Tension -4>N0 Shear -cpV0 Tension -4>N0 Shear -4>V0 Nominal internal Nominal anchor thread embed. f'c = 3,000 psi f'c = 4,000 psi f'c = 3,000 psi f'c = 4,000 psi f'c = 3,000 psi f' C = 4,000 psi diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in.(mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb(kN) 1-5/8 280 305 610 610 330 360 1/4-20 (41) (1.2) (1.4) (2.7) (2.7) (1 .5) (1.6) UNC 2-1/2 605 700 610 610 635 735 1/4 (64) (2.7) (3.1) (2.7) (2.7) (2.8) (3.3) 1-5/8 280 325 915 915 330 380 3/8-16 (41) (1 .2) (1.4) (4.1) (4.1) (1.5) (1.7) UNC 2-1/2 605 700 915 915 635 735 (64) (2.7) (3.1) (4.1) (4.1) (2.8) (3.3) 1 See Section 3.1.9.4 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x h"""' (nominal embedment). 4 Tabular values are lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular Values control. f'c = 3,000 psi 1/'c = 4,000 psi (20.7 MPa) (27.6 MPa) lb (kN) lb (kN) 610 610 (2.7) (2.7) 610 610 (2.7) (2.7) 915 915 (4.1) (4.1) 915 915 (4.1) (4.1) 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by cxN_,_ = 0.75. 8 For seismic shear, an additional factor must be applied to the cracked concrete tabular values for seismic conditions: 1/4-in diameter by 1-5/8-in nominal embedment depth •ex,,_,..,= 0.44 1/4-in diameter by 2-1/2-in nominal embedment depth· ex_,_..,,= 0.85 See Section 3.1.8.6 for additional information on seismic applications. 322 Hilti, Inc. {US) 1-800-879-8000 I www.us.hilti.com I en espai'iol 1-800-879-5000 I Hilti {Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2016 Mechorncol Anchoring Systerns KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3. 7 Figure 2 -Installation of Hilti KWIK HUS-EZ I (KH-EZ I) in soffit of concrete over steel deck floor and roof assemblies Min. 4-1/2" Min.1-1/4•- Min. 4-1/2" (typica~ FMeedge Min. 12" (typicaQ Minimum 20gauge steel deck 1 Anchors may be placed in the upper or lower flute of the steel deck profile provided the minimum concrete cover above the drilled hole is satisfied. Anchors in the lower flute may be instalfed with a maximum 1-inch offset in either direction from the center of the flute. The offset distance may be increased proportionally for profiles with lower flute widths greater than those shown provided the minimum lower flute edge distance is also satisfied. fil 3.3. 7 .3.2 Canadian Limit State design El Limit State Design of anchors is described in the provisions of CSA A23.3-14 Annex D for post-installed anchors tested and assessed in accordance with ACI 355.2 for mechanical anchors and ACI 355.4 for adhesive anchors. This section contains the Limit State Design tables with unfactored characteristic loads that are based on the published loads in ICC Evaluation Services ESR-3027. These tables are followed by factored resistance tables. The factored resitance tables have characteristic design loads that are prefactored by the applicable reduction factors for a single anchor with no anchor-to-anchor spacing or edge distance adjustments for the convenience of the user of this document. All the figures in the previous ACI 318-14 Chapter 17 design section are applicable to Limit State Design and the tables will reference these figures. For a detailed explanation of the tables developed in accordance with CSA A23.3-14 Annex D, refer to Section 3.1 .8. Technical assistance is available by contacting Hilti Canada at (800) 363-4458 or at www.hilti.ca Table 9 -Steel resistance for Hilti KWIK HUS-EZ I carbon steel screw anchor1•2 Nominal Internal anchor thread Tensile3 diameter diameter N .. , in. (UNC) lb (kN) 3,370 1/4 1/4-20 (15.0) 3,370 1/4 3/8-16 (15.0) See section 3.1.8.6 to convert design strength value to ASD value. Shear' Shear5 v .. , V sar,eq lb (kN) lb(kN) 750 335 (3.3) (1 .5) 725 620 (3.2) (2.8) 2 Hilti KWIK HUS-EZ I carbon steel screw anchors are to be considered brittle steel elements. 3 Tensile N.., = A,.,N 4>, f.,,, R as noted in CSA A23.3-14 Annex D. fil 4 Shear determined by static shear tests with V.., < A,.,v <t>, 0.6 f,,. R as noted in CSA A23.3-14 Annex D. 5 Seismic shear values determined by seismic shear tests with V ....... < A, •. v <t>, 0.6 f,,. R as noted in CSA A23.3-14 Annex D. See section 3.1 .8. 7 for additional information on seismic applications. Hilti, Inc. (US) 1-800-879-8000 I www.us.hitti.com I en espanol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hitti.ca I Anchor Fastening Technical Guide 2016 323 Me< h,1n1c:c1I Anchoring Systen1s 3.3. 7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 10 -Hilti KWIK HUS-EZ I design information in accordance with CSA A23.3-14 Annex D1 l+I Nominal anchor diameter Ref Design parameter Symbol Units 1/4 A23.3-14 AnchorO.D. in. 1/4 d. (mm) (6.4) in. 1.18 1.92 Effective embedment2 h.1 (mm) (30) (49) Minimum nominal embedment2 in. 1-5/8 2-1/2 hnom (mm) (41) (64) in. 3-1/4 4-1/8 Minimum concrete thickness hmin (mm) (83) (105) Critical edge distance in. 2.00 2.78 cac (mm) (51) (71) in. 1.5 Minimum spacing at critical edge distance 5min,cac (mm) (38) in. 1.50 Minimum edge distance c min (mm) (38) Minimum anchor spacing at minimum edge distance for s > in. (mm) 3.0 (76) in. 2 2-7/8 Mininimum hole depth in concrete ho (mm) (51) (73) Minimum specified ultimate strength futa psi 125,000 (N/mm2) (862) Effective tensile stress area in2 0.045 Ase,N (mm2) (29.0) Steel embed. material resistance factor for reinforcement 4> -0.85 8.4.3 Resistance modification factor for tension, steel failure modes3 R -0.70 D.5.3 Resistance modification factor for shear, steel failure modes3 R -0.65 D.5.3 Factored steel resistance in tension N .. , lb 3,370 D.6.1.2 (kN) (15.0) lb 750 D.7.1.2 Factored steel resistance in shear v,., 1/4-20 UNC (kN) (3.3) internal thread lb 335 Factored steel resistance in shear, seismic V (1.5) sar,eq (kN) lb 725 D.7.1.2 Factored steel resistance in shear v,., 3/8-16 UNC (kN) (3.2) internal thread lb 620 Factored steel resistance in shear, seismic V sar,eq (kN) (2.8) Coeff. for factored cone. breakout resistance, uncracked concrete k_,, __ -10 D.6.2.2 Coeff. for factored cone. breakout resistance, cracked concrete kcc, -7 D.6.2.2 Modification factor for anchor resistance, tension, uncracked conc.4 ljJc N -1.0 D.6.2.6 Anchor category --3 1 D.5.3 (c) Concrete material resistance factor 4>_ -0.65 8.4.2 Resistance modification factor for tension and shear, concrete failure modes, Condition 85 R -0.75 1.00 D.5.3 (c) Factored pullout resistance in 20 MPa uncracked concretes lb 665 1,645 D.6.3.2 N pr,uncr (kN) (3.0) (7.3) Factored pullout resistance in 20 MPa cracked concretes lb 340 815 D.6.3.2 N pr.er (kN) (1.5) (3.6) lb 275 815 D.6.3.2 Factored seismic pullout resistance in 20 MPa cracked concretes N (1.2) (3.6) pr,eq (kN) 1 Design information in this table is taken from ICC-ES ESR-3027, dated December, 2015, tables 2, 3, and 4, and converted for use with CSA A23.3-14 Annex D. 2 See figure 1 of this section. 3 The KWIK HUS-EZ I is considered a brittle steel element as defined by CSA A23.3-14 Annex D section D.2. 4 For all design cases, ljJ,,N = 1.0. The appropriate coefficient for breakout resistance for cracked concrete (k,_.) or uncracked concrete (k,_...) must be used. 5 For use with the load combinations of CSA A23.3-14 chapter 8. Condition B applies where supplementary reinforcement in conformance with CSA A23.3-14 section D.5.3 is not provided, or where pullout or pryout strength governs. For cases where the presence of supplementary reinforcement can be verified, the resistance modification factors associated with Condition A may be used. 6 For all design cases, ljJ,.e = 1.0. NA (not applicable) denotes that this value does not control for design. See section 4.1.4 of ESR-3027 for additional information. 324 Hilti, Inc. (US) 1-800-879-8000 I www.us.hilti.com I en espaiiol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2016 Mechc1n1ec1I Anchonnq Systerns KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3. 7 Table 11 -Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure in uncracked concrete1,2,3,4,5 Nominal Tension -N, Shear -V, anchor Effective Nominal f '0 = 20 MPa f'0 = 25 MPa f '0 = 30 MPa f '0 = 40 MPa f '0 = 20 MPa f '0 = 25 MPa f '0 = 30 MPa diameter embed. embed. (2,900psi) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) in. in.(mm) in.(mm) lb (kN) lb (kN) lb (kN) lb (kN) lb(kN) lb (kN) lb (kN) 1.18 1-5/8 665 710 750 820 805 900 985 1/4 (30) (41) (3.0) (3.2) (3.3) (3.6) (3.6) (4.0) (4.4) 1.92 2-1/2 1,645 1,840 2,015 2,325 2,225 2,490 2,725 (49) (64) (7.3) (8.2) (9.0) (10.3) (9.9) (11.1) (12.1) Table 12 -Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure in cracked concrete1,z.3.4,5 Nominal Tension -N, Shear -V, anchor Effective Nominal f ' = 20 MPa C f '0 = 25 MPa f '0 = 30 MPa f '0 = 40 MPa f '0 = 20 MPa f'0 = 25 MPa f '0 = 30 MPa diameter embed. embed. (2,900psi) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) in. in.(mm) in.(mm) lb (kN) lb(kN) lb (kN) lb (kN) lb (kN) lb(kN) lb (kN) 1.18 1-5/8 340 360 385 415 565 630 690 1/4 (30) (41) (1 .5) (1.6) (1 .7) (1.9) (2.5) (2.8) (3.1) 1.92 2-1/2 815 915 1,000 1,155 1,560 1,740 1,910 (49) (64) (3.6) (4.1) (4.4) (5.1) (6.9) (7.7) (8.5) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. f '0 = 40 MPa (5,800 psi) lb (kN) 1,135 (5.1) 3,145 (14.0) fil f'0 = 40 MPa (5,800 psi) lb(kN) 795 (3.5) 2,205 (9.8) 3 Apply spacing, edge distance, and concrete thickness factors in tables 5 to 6 as necessary. Compare to the steel values in table 9. The lesser of the values is to be used for the design. 4 Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by \ as follows: for sand-lightweight, >... = 0.68; for all-lightweight, >... = 0.60 5 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth -cxN,seis = 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth -cxN , = 0.75 . See section 3.1.8. 7 for additional information on seismic applications. fil II Hilti, Inc. (US) 1-800-879-8000 I www.us.hilti.com I en espariol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2016 325 Mee ll,1r11c,1I Anchoring Systerns 3.3. 7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 13 -Hilti KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck1·2·3·4·5•6·7 Installation in lower flute Installation in upper flute Nominal Tension -N, Shear -V, Tension -N, Shear -V, Nominal internal Nominal anchor thread embed. f'c = 20 MPa f'c = 30 MPa f'c = 20 MPa f'c = 30 MPa f 'c = 20 MPa f'c = 30 MPa f'c = 20 MPa f'c = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in.(mm) kN kN kN kN kN kN kN kN 1-5/8 585 660 720 810 1/4-20 (41) (2.6) (2.9) 475 475 (3.2) (3.6) 560 560 1/4 UNC 2-1/2 1,200 1,470 (2.1) (2.1) 1,255 1,535 (2.5) (2.5) (64) (5.3) (6.5) (5.6) (6.8) 1-5/8 585 660 720 810 3/8-16 (41) (2 .6) (2.9) 565 565 (3.2) (3.6) 845 845 1/4 UNC 2-1/2 1,200 1,470 (2.5) (2.5) 1,255 1,535 (3.8) (3.8) (64) (5.3) (6.5) (5.6) (6.8) Table 14 -Hilti KWIK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck1,2.3•4•5•5•7,s 61 Installation in lower flute Installation in upper flute Nominal Tension -N, Shear -V, Tension -N, Shear -V, Nominal internal Nominal anchor thread embed. f'c = 20 MPa f'c = 30 MPa f'c = 20 MPa f'c = 30 MPa f'c = 20 MPa f'c = 30 MPa f 'c = 20 MPa f'c = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in.(mm) kN kN kN kN kN kN 1-5/8 300 340 365 415 1/4-20 (41) (1.3) (1.5) 475 475 (1.6) (1 .8) 1/4 UNC 2-1/2 595 730 (2.1) (2.1) 625 765 (64) (2.6) (3.2) (2.8) (3.4) 1-5/8 300 340 365 415 3/8-16 (41) (1.3) (1.5) 565 565 (1.6) (1.8) 1/4 UNC 2-1/2 595 730 (2.5) (2.5) 625 765 (64) (2.6) (3.2) (2.8) (3.4) 1 See Section 3.1 .8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x hnom (nominal embedment). 4 Tabular value is for lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular values control. kN kN 560 560 (2.5) (2.5) 845 845 (3.8) (3.8) 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by a._,...= 0.75. 8 For the following anchor sizes, an additional factor for seismic shear must be applied to the cracked concrete tabular values for seismic conditions: For the 1/4x1 -5/8 anchor -a,_,...= 0.45 For the 1/4x2-1/2 anchor -a,_...,= 0.85 See Section 3.1.8. 7 for additional information on seismic applications. 3.3. 7 .3.3 Allowable stress design for FM sprinkler systems Table 15 -Hilti KWIK HUS-EZ I (KH-EZ) tested load values for FM approval for automatic sprinkler systems1 FM maximum Nominal embedment FM tension test load pipe diameter Hanger rod size in. lb in. 3/8-16 UNC 1-5/8 1,475 4 2-1/2 1 Tested in accordance with FM Approval Standard for Pipe Hanger Components for Automatic Sprinklers Systems Class Numbers 1951, 1952 and 1953. 326 Hilti, Inc. (US) 1-800-879-8000 I www.us.hilti.com I en espanol 1-800-879-5000 I Hilti (Canada} Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2016 Mecl1,u11cc1I Ancl1onng Systenis KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3. 7 Table 16 -Hilti KWIK HUS-EZ I (KH-EZ I) allowable stress design values for installations into hollow core concrete panels1•2 Min. effective Allowable load3 Ultimate load embedment h0, Hanger rod size in. Tension lb Shear lb4•5 Tension lb Shear lb4•5 1/4-20 UNC 485 1,930 1-3/8 455 1,810 3/8-16 UNC 755 3,025 The admissible anchor location must be established to prevent damage to the prestressed cable during the drilling process. Verify the location and height of the cable with the hollow core plank supplier to confirm admissible anchor location. 2 Minimum compressive strength of prestressed concrete is 7,000 psi. Published ultimate loads represent the average results conducted in local base materials. Due to variations in materials and dimension! configurations, on-site testing is required to determine the actual performance. 3 Allowable loads calculated with a factor of safety of 4 4 The bottom of the shear plane adjacent to the top of the coupler. 5 Shear values controlled by the steel strength of the screws used to fasten the shear fixture to the KH EZ-I Screw Anchor. The minimum tensile strength of the screw was 125 ksi. Shear design values should consider the screw or threaded rod steel strength. Figure 3 -Installation of Hitti KWIK HUs-EZ I (KH-EZ I) in hollow core concrete • MllllllbllanchorlDclllorl 1' 1· 3.3. 7 .4 Installation instructions Installation Instructions For Use (IFU) are included with each product package. They can also be viewed or downloaded online at www.us.hilti.com (US) and www.hilti.ca (Canada). Because of the possibility of changes, always verify that downloaded IFU are current when used. Proper installation is critical to achieve full performance. Training is available on request. Contact Hilti Technical Services for applications and conditions not addressed in the IFU. 3.3. 7 .s Ordering information1 Internal thread Internal thread Hole Minimum Description diameter length diameter embedment Qty/ box KH-EZ 1/4x1-5/8 11/4 1/4 3/8 1/4 1-5/8 100 KH-EZ 1/4x2-1/2 I 1/4 1/4 3/8 1/4 2-1/2 100 KH-EZ 1/4x1-5/8 I 3/8 3/8 7/16 1/4 1-5/8 100 KH-EZ 1/4x2-1/2 I 3/8 3/8 7/16 1/4 2-1/2 100 1 All dimensions in inches. m Hilti, Inc. (US) 1-800-879-8000 I www.us.hilti.com I en espanol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2016 327 @TOLCO Fig. 25 -Surge Restrainer Size Range -One size fits 3/4" thru 2" pipe Material -Pre-Galvanized Steel Function -Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals -Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish -Pre-Galvanized Order By -Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344, 108 ....... .......__ /.· ··, . . · ·, / .. i i c@us US1ED COOPER B-UNE 1375 Sampson Ave • Corona, CA 92879 • 800.786.5266 • FAX: 951.737.0330 ,,,, COOPER B-Line TOLCO www.tolco.com . NIBc□· Rev1 s1or1 8 15 2005 Fig. 98 -Rod Stiffener Size Range -Secures 3/8" thru 7/8" hanger rod Material -Carbon Steel Function -Secures channel to hanger rod for vertical seismic bracing. Approvals -Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish -Electro Galvanized Note -Available in HOG finish or Stainless Steel materials. Order By -Figure number Fig. 99 -All Thread Rod Cut to Length Size Range -Secures 3/8" thru 7/8" rod in 1 " increments Material -Carbon Steel Maximum Temperature -750°F Finish -Plain Note -Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By -Figure number, rod diameter, rod length and finish Fig. 100 -All Thread Rod Full Lengths Size Range -Secures 3/8" thru 7/8" rod in 10' lengths Material -Carbon Steel Maximum Temperature -750°F Finish -Plain Note -Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By -Figure number, rod diameter and finish Rod Size 1/4 3/8 1/2 5/8 3/4 7/8 Dimensions • Weights Max Rec. Load Lbs. For Service Temps 650°F 750°F 240 215 610 540 1130 1010 1810 1610 2710 2420 3770 3360 4960 4420 8000 7140 11630 10370 Approx. Wt./100 12 29 53 84 123 169 222 360 510 Component of State of @ California OSHPD Approved C . lJStEI Seismic Restraints System Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 3/8 1/2 5/8 3/4 7/8 650°F 750°F 610 1130 1810 2710 3770 540 1010 1610 2420 3360 ■ OFFICUMANUFACTURING FACILITY• 1375 SAMPSON AVE.• COROIJA, CA 92879 • PH 951 737 5599 • FAX 951.737.0330 CUSTOMER SERVICE • 800 786 5266 w w w.tolco,com Pipe Hangers Fig. 200 -"Trimline" Adjustable Band Hanger (Cooper B-Line Fig. B3170NF) Fig. 200F -"Trimline" Adjustable Band Hanger with Felt Lining (Cooper B-Llne Fig. B3170NFF) Fig. 200C -"Trimline" Adjustable Band Hanger with Plastic Coated (Cooper B-Line Fig. B3170NFC) Fig. 200S -"Trimline" Adjustable Band Hanger with Non-Captured Nut c@us USTBI ~ Size Range: Fig. 200 -1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: • (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. • (2112" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171 E & A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. Pipe Stze Rod s,ze Part No. ,n 1mm) 2G0-1/z 1/2'' (15) 3/s"-16 a.3/4 3/4" (20) 3/a"-16 2G0-1 1" (25) 3/a"-16 2G0-11/4 11/4" (32) 3/a"-16 20D-111z 11/2'' (40) 3/a"-16 2G0-2 2" (50) 3/a"-16 2G0-211z 2112'' (65) 3/a"-16 2G0-3 3" (75) 3/a"-16 200-31/z 31/2'' (90) 3/a"-16 2G0-4 4" (100) 3/s"-16 2G0-5 5" (125) ½"-13 ... 6" (150) 1/2"-13 20N 8" (200) 1/2''-13 Fig. 200C A in (mm, ,n 31/s" (79.4) 25/s" 31/s" (79.4) 21/2" 33/a" (85.7) 25/a" 33/4'' (94.0) 27/a" 37/a" (98.4) 27/s" 41/2'' (114.3) 3" 55/g" (142.9) 41/s'' 57/g" (149.1) 4" 73/s" (187.3) 51/4" 73/g" (187.3) 5• 91/s'' (231.8) 6¼" 101/a'' (257.2} 63/4'' 131/8'' (333.4) 83/4" B Imm (66.7) (63.5) (66.7) (73.0) (73.0) (76.3) (104.7) (101.6) (133.3) (127.0) (1 58.7) (171.4) (222.2) Ag. 200-1 to 200-2 Fig. 200F Approx . Wt./100 lbs 1kg) 11 (5.0) 11 (5.0) 12 (5.5) 13 (5.9) 14 (6.4) 15 (6.9) 27 (12.3) 29 (13.3) 34 (15.6) 35 (16.0) 66 (30.2) 73 (33.4) 136 (62.3} A Ag. 200-112. 200-S/4 Fig. 200-2112 to 200-8 Fig. 200 Fig. 200S All dimensions in charts and on drawings are in Inches. Dimensions shown In parentheses are in millimeters unless otherwise specified. Fig. 200M -"Trimline" Adjustable Band Hanger for Metric Rod Size Range: Fig. 200 -1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: • (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. • (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (;3/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications 'NW-H-171 E & A-A-1192A, Type 1 0 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343"C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. Pipe Size Rod Size Part No. in !mm1 ,n 20IJM8-1'2 ½" (15) MB 31/s" 200M1•½ 1/2'' (15) M10 31/a" 20IJM8-3/4 3/4" (20) MB 31/s'' 200M1-..3/4 3/4'' (20) M10 31/a" 200M8-1 1" (25) MB 33/s" 200M1-..1 1" (25) M10 33/s" 200M8-11/4 11/4" (32) MB 33/4'' 200M1-..111, 11/4" (32) M10 33/4'' 20IIM8-11/2 11/2'' (40) MB 37/g" 2DDM1-..1112 1 t/2" (40) M10 37/s" 200M8-2 2" (50) MB 4lf2" 200M1-..2 2" (50) M10 41/2'' A (mm) (79.4) (79.4) (79.4) (79.4) {85.7) (85.7) (94.0) (94.0) (98.4) (98.4) (114.3) (114.3) in 25/a'' 25/s" 21/2'' 21/2'' 25/s" 25/s" 27/s" 27/s" 27/g" 27/s" 3" 3" 200M-2½ 2½" (65) M10 55/g" (142.9) 41/g" 200M-3 3" (75) M10 57/g" (149.1) 4" 200M-3½ 3½" (90) MlO 73/g" (187.3) 51/4'' 2GIIM 4" (100) M10 73/s" (187.3) 5" 2CNIM-5 5" (125) M12 91/8'' (231.8) 61/4" 20IIIH 6" (150) M12 101/8" (257.2) 63/4" ..... 8" (200) M12 131/8'' (333.4) 83/4'' B (mm1 (66.7) (66.7) (63.5) {63.5) (66.7) (66.7) (73.0) (73.0) (73.0) (73.0) (76.3) (76.3) (1 04.7) (1 01.6) (1 33.3) (1 27.0) (1 58.7) (171.4) (222.2) Pipe Hangers Ag. 200-1 to 200-2 Approx. Wt./100 lbs \kg) 11 (5.0) 11 (5.0) 11 (5.0) 11 (5.0) 12 (5.5) 12 (5.5) 13 (5.9) 13 (5.9) 14 (6.4) 14 (6.4) 15 (6.9) 15 (6.9) 27 (12.3) 29 (13.3) 34 (15.6) 35 (16.0) 66 (30.2) 73 (33.4) 136 (62.3) A f)TOLCCT c@us USTD <8> -·· Fig. 200-112. 20()-3/4 Fig. 200-2112 to 200-8 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Hangers Fig. 200H -Heavy Duty Band Hanger (For Trapeze) Size Range: 2" (50mm) thru 4" (100mm) trapeze pipe size. Material: Steel -Pre-Galvanized to G40 Spec Function: Designed primarily to support substantially heavier loads than is normally intended for the nominal hanger size. Used extensively to support trapeze installations and the increased loads from both above and below the trapeze assembly. Features: Furnished with 3/s"-16 or 1/2"-13 adjusting threaded ring nut. Approvals: Underwriters Laboratories listed in the USA (UL} and Canada .. (cUL). Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343'C) Finish: Pre-Galvanized Order By: Figure number, pipe size and rod size. Important Design Note. Because of the increased loads applied to the trapeze assembly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended. Pipe Size Rod Size A Part No. in imrn1 ,n (mm, in 20llll-2.3/a 2" (50) 3/s"-16 49/ts" (115.9) 37/32" 20IIH-2-1h 2" (50) 1/2''-13 423/32" (119.8) 33/g" 20llll-21 /2.3/a 21/2'" (65) 3/s"-16 55/15" (134.9) 323/32" 20llll-21 f2-1 f2 21/2" (65) ½"-13 515/32" {138.9) 37/a" DJH-3-3/a 3" (75) 3/s"-16 53/4'' (146.0) 327/32'' 200fl-3-1 /2 3" (75) 112•-13 57/s" (148.1) 331/32" 20IJH-4.3/a 4" (100) 3/s"-16 67/s" (174.6) 47/16" 200H-4-1f2 4" (100) 1/2''-1 3 71/32" (178.6) 419/32'' A B Approx. Wt./100 (mm1 lbs 1kg) (81.7) 48 (21 .8) (85.7} 45 (20.4) (94.4) 59 (26.7) (98.3) 56 (25.4) (97.6) 63 (28.6) (100.8) 60 (27.2} (112.7) 76 (34.5) (1116.7) 73 (33.1) • Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13 . .. All sizes are UL Listed to support up to a• pipe at max spacing per NFPA 13. For 6" (150mm) and 8" (200mm) trapeze pipe, consult factory. NI dimensions in charts and on drawings are in inches. Dimensions shown in parenlheses are in millimeters unless otherwise specified. Description LubeFit® is a vegetable fiber based lubricant for all gasketed fittings, including grooved couplings for fire sprinkler systems. It is non staining* and does not support bacterial growth. LubeFit® can be easily applied in temperatures from -10°F to 150°F. LubeFit® is non-toxic and water soluble. Under normal conditions, LubeFit® is not harmful to the skin. Design Criteria/Data • Water dispersible • Applies equally well to wet or dry surfaces • Suitable for all types of pipe lines, including potable water • Excellent working range -10° to 150° • Will not support bacteria • Will not deteriorate natural or Synthetic rubber, plastic gaskets or caston iron pipe • FGG/BM/CZ™ System Compatible Program* • Certified to NSF/ANS/Std 61 -G *FBC™ System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL+ 1 760 599-11 68 + 1 800 344-1822 FAA+ 1 800 344-3775 Application LubeFit® should be applied in an even and thin amount over the parts to be lubricated. Avoid applying excessive amounts. The best applicaion is achieved when applying by hand. Clean all dirt, burrs and foreign matter from the joint surfaces. Make certain the gasket is properly located. Apply an even coating of lubricant to all fitting surfaces and gasket. Assemble the joint according to the pipe fitting manufacturer's directions. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, fl ush with water for 5 minutes. If discomfort persists get medical attention. *Will stain untreated porous surfaces such as concrete if not cleaned from the surface immediately. © 2012 Fire Protection Products, Inc. FPPI®, LubeFi~ are registered trademarks of Fire Protection Products, Inc. FGG/BMICZ", Blaze-Maste~. AowGuard Gold® and Corzan"' are registered trademarks of Noveon IP Holdings Corp. •• ..... ~ MAD■IN U.LA. Specifications Appearance: Dense, paste like consistency and is light brown or tan in color. Contains: Potassium Oleate, Propylene Glycol and Mica. Contains NO PETROLEUM. Packaging: 2Ib (1-quart approx.) 55-gl drum (400 lbs. approx.) See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com CAUTION: Eye irritant. Avoid contact with eyes. Wash thoroughly after use. • Description Pipefit® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique blend of materials provides superior thread sealing qualities over other similarly priced sealants. The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipefit® also adheres well to hot oily pipe present in "high speed' fabrication operations. Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. *FBC™ System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL+ 1 760 599-1168 + 1 800 344-1822 FAX+ 1 800 344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipefit® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been "made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipefit® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. © 2012 Fire Protection Products, Inc. FPP~. LubeFit" are registered trademarks of Fire Protection Products, Inc. FBC'", BlazeMaste~. FlowGuard Gold" and Corzan• are registered trademarks of Noveon IP Holdings Corp. •• ~ ... ~ MAD■ IN U.LA. Specifications Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 oz. 32 oz. BIG 1 gl. 5 gl. 55 gl. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com Description ThreadFi CLEAR Thread Cutting Oil for Sprinkler Pipe is an excellent heavy duty, light colored cutting oil for all types of ferrous metal. It's special combination of anti-wear and anti-weld additives provides all the necessary lubricity and cooling modern pipe threading operations require. This balanced combination of additives will help improve die life and thread quality over other cutting oils and is Chlorine free. ThreadFit Clear's low smoke/ low odor formulation makes it ideal for use in high speed threading applications. Features • Heavy Duty Cutting Oil • Excellent Tool Life • Chlorine Free • All types of ferrous metal or pipe • Improved Surface Finish • Low Odor • Low Smoke SYSTEM COMPATIBLE *FBC'" System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. Ei Spears® Compatible indicates that ThreadFit® CLEAR has been tested by Spears~ Manufacturing to be compatible with Flameguard® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL+ 1 760 599-1168 + 1800344-1822 FAX + 1 800 344-3775 Installation ThreadFi can be used in automatic and hand held applicators. Fill oil reservoir according to equipment manufacturers specifications. Mixing of different types of threading oils is not recommended. DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Change oil regularly for optimum performance. Contains petroleum oil. Avoid breathing mists or vapors. Avoid eye contact and prolonged or repeated contact with skin. Wear safety glasses or goggles. Use good personal hygeine. Dispose of used oil in accordance with all local, State and Federal ordinances and regulations. Consult Material Safety Data Sheets for additional safety and handling information. DO NOT MIX WITH OTHER THREAD CUTTING OILS OR CONTAMINANTS. •• © 2013 Rre Protection Products, Inc. FPPP', ThreadRI" are registered trademarks of Fire Protection Products, Inc. Ill. .. ·-· --_.,.. ----- Specifications Appearance: Clear amber liquid. Packaging: 1 gl. (6/case) 5 gl. Pail 55-gl drum 275-gl tote CAUTION: Skin contact: wash thoroughly with soap and water. Eye contact: flush eyes with water for at least 15 minutes and seek medical attention. Ingestion: consult a physician immediately. Inhalation: move affected person(s) to fresh air and seek medical attention. See MSDS for first aid instructions. Spill or Leak: Soak up with an oil absorbent compound. Follow all state, local, Federal regulations for disposal. Don't pollute. Conserve our resources-Please recycle this container. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com This product is registered with CHEMTREC, a 24-hour emergency hotline. They may be reached at 1 800 424-9300 .