HomeMy WebLinkAboutDWG 356-7M; CT 96-01; GRAND PACIFIC PALISADES RESORT; 01-09l 2, 4. 5. 6, GENERAL NOTES RECYCLED WATER NOTES AL.L. wa:?K $1-aiALL BE DONE; N ACCORDANCE WITH T~ CARLSBAD M.JNICIPAL WATS! DtSTOOTS "CARLSBAD RECLAIMA TION RULES E RE'GULA TIONS FOR CONSTRUCTION OF RECYCLE:□ WATER MAINS" DATED OCTOBER 1993. DRII\KING FOUNTAINS Sl-alALL 8E PROTECTED FROM SPRAY OF RECYCLED WATER. BEST MANAGEMENT PRACTICES $1-aiALL BE USED TO MINMIZE RECYCLED WATER ENCROACl-alMENT ON PUBLIC FACILITIES SU~ AS PICNIC TABLE:$, ElBQ'S, PLAYGROUNDS. SAND TOT LOTS, ETC. BEST MANAGEMENT PRACTICES SHALL l!iE USED TO E:LIMINATE OR CONTROL. TO Tl-all:: BEST E:XTENT POSSIBLE: PONDNG, Rl..N-0FF, OVERSPRAY AND ~STING. HOSE EIBS ARE STRICTLY PROHIBITED. ON-SITE CR0SS--CON\ECTIONS BETWEEN RECYCU'::D WATl!!!R LINE!:$ AND POTAE!ILE WATER L.INES IS STRICTLY PR0HBITED. NO SL.BSTITUTION OF PIPE MATERIALS WILL. BE AL.L.OWE:D WITHOUT PRIOR AF'PR0VAL OF Tl-all:: CITY OF CARLSBAD MUNICIPAL WATE;R DISTRICT, 7. AL.LON SITE PF'ES SHALL HAVE WARNNG TAPE PER CARLSBAD ML.NICIPAL WA-re:! DISTRICT RULES AND RE:GL.lA TI0NS. 8.• THE IRRIGATION SYSTE;M SHALL RUN BE:TWEE:N Tl-I: HOLQS OF 10•00 PM AND 6'00 AM Tl-all!: FOLLOWING MORNNG <SPOT IRl<IGA TION COULD BE DONE AT A DIFF51ENT TIM:: WITH QUALFIED SUPERVISION PERSONNEL ON SITE=). 9, PR0V0E: A MINIMUM OF AT LEAST 18 INCHES OF C0VE:R 0VIS? ALL WRING Al'D PPING. IO. NON-DESIGNATED use Al<!::AS SHALL BE PR0TE:CTED FROM CONT ACT WITH l:!ECYCLE:D WATE:R, Wl-alETl-alER BY WINDBLOWN SPRAY OR BY DIRECT APPLICATION Tl-alROUGl-al IRRIGATION OR OTHER use. LACK OF Pl20TECTION, WHETHER ElY DESIGN, CONSTl2UCTI0N Pl2ACTICE 012 SYSTEM OPERATION, IS STRICTLY PR0HN31TED, I. !.'RIGA TION 1-aiE=ADS SHAL.l. BE RE=I..0CA TE:D 012 ADJUSTE:D TO PREVl'::NT 0VER-SPRA YNG ON SIDEWALKS, STREETS AND NON-DESIGNATED USE A12EAS. 12. RECYCLED WATER QUICK COLPLING VALVES SHALL BE OF A TYPE De51GNED F012 THE USE ON RECYCLED WATE:R DISTRIBUTION SYSTEMS (SPIKES NOT INTEl2Cl-alANGEABLE WITH POTABLE WATER QUICK COUPLER SPKES PER CAl2LSElAD MUNICIPAL WATER DISTl21CT'S RULES AND REGULATIONS. 13. METERS Sl-alALL BE SIZED BY THE CITY OF CAl2LSBAD ML.NICPAL WATER DISTRICT. 14. ALL IRIRIGA TI0N PF'ES Sl-alALL BE STENCILED WITl-al Tl-alE WARNING, "NON-POT ABLE OR RECYCLED WATER", COLOR-CODED (PURPLE) AND LAID WITH WARNING TAPE AND STENCILING ORIENTED TOWARD THE TOP OF Tl--lE TRENCl-l PER Tl--lE CARLSBAD MUNICIPAL WATER DISTRICTS RULES AND REGULATIONS. 15. ALL POTABLE WATER AND RECYCLED WATER PIPING Sl--lAL.L. BE INSTALLED WITH Tl-alE STENCLING ORIENTED TOWARD Tl-alE TOP OF Tl-alE TRENCl-l. 16. WI-EN POTABLE WATEl2 LINE AW RECYCLED WATE;R LIN:= CROSS, THE RECYCLED LINE SHALL BE INST AL.LED WITHIN A PROTECTIVE SLEEVE. THE SLEl;:VE SHAL.L c:XTEND 10 FEl!:T Fl<OM c:ACH SIDE, FROM THE CENTER LINE OF POT ABLE LINE, FOR A TOT AL OP 20 PEET, 17. A 10 FOOT 1-0RIZ0NT AL SEPERA TION BETWEEN POT ASI.E WATER AND RECYCLl;:D WATER MAINS MUST BE MAINT AIN=D AT ALL TIMES. T~ POT ABLE LNE:S MUST BE INST AL.LED ABOVE THE RECYCLED LINE. 18, A MINMUM OF 12 INCl-eS 01" VERTICAL SEPE:RA TION E!ll!:T~EN UTLITIES M.J$T BE MAINTAINED AT ALL TME:S. 19.• DEVE=I..OPER / CONTRACTOR S~L CONDUCT A Cl2055-COI\Nl!!CTION TEST AND COVEl<AGI!! TEST AS DIRl;:CTED BY THE CARL.SBA□ MLNCIPAL WATER DISTRICT c:NGINE:ER OR Thi:: SAN DIEGO COUNTY DIEPARTMENT OF ENVIRONM::NTAL. HE:ALTl--l PRIOR TO ANY USE OP RECLAIMED WATER. 20. QUICK COUPLING VALVES USED IN RECYCLED WATE:R SYSTEMS SI--IALL CONl"0l:!M TO Tl-f: FOLLOWING. A. RECYCLED WATE;I:! -QUICK COUPLING VALVES USED N RECYCLED WATB! SYSTEMS SI--IALL I--IAVE ACME TYPE THREADS AND PURPLE COLORED L0CKNG COVERS PERMANl;:NTLY ATTAChl::D TO THE VALVE. QUICK C0UPLNG VALVES SHALL BE NaSON NO. 7645, HLNTER NO. HVI00A-RL-NP OR APPl20VE:D E:QUAL ($PIKE$ SHALL NOT BE INTl;:RCl-alANGEAELE WITH POTABLE: WATl;:R QUICK COUPLER SPIKES) 21. Thi:: l.!EQURl;:D Cl<0SS-C0NNE:CTION INSPECTION SHAL.l. BE DON:= BY EITHER THE: CARL.$9AD MUNICIPAL WATE;R DISTRICT AND/OR THE SAN DIE:G0 COUNTY DEPAl<TMENT OF E:NVIR0NMENT AL HEAL Tl-I. COPIES OF INSPECTION REPORTS WILL Bi;: PORWARDED 22.• 2S.• 24. 25. 26. TO THE NON-NSPECTING PARTY. DEVELOPIS? SHALL SI--I0W THE LOCATION OF R.C. SIGNS 'DO NOT DRINK' ON THESE: PLANS. AN ON-SITE: USER / $1..JPERVISOR $HALL BE DESIGNATED N WRITING, Tl--llS NDIVIDUAL SHALL 91;: FAMILIAR WITH PLUMBING SYSTEMS WITHIN THE PROPERTY, WITI--I Tl-IE BASIC CONCEPTS OF BACKFL0W / Cl<0SS CONNECTION PROTECTION, AND TI-E SPECIPIC REQUREMENTS OF A RECYCLED WATER SYSTEM. COPIES OF THE DESIGNATION, WITH CONTACT PH0I\E NUMBERS $1-aiAL.L BE PROVIDED TO THE SAN DIEGO COUNTY DEPARTMENT OF ENVll<0NME:NTAL. hl::ALTl--l AW CARLSBAD ML.NICPAL WATER DISTRICT. N CASE OF EMERGENCY CONTACT• MAINTENANClc: SUPERVISI0R OR APTER HOURS CONTACT MAINTE;NANClc: SUPERVISI0R LARIRY W00DWAl2D AT (619) 271-7050 LARIRY W0ODWAl2D AT (619) 271-7050 $1--l0W ALL PUBLIC ANIJ PRIVATE POTABLE WATER MANS ON IMPROVl!M!!NT PLANS. • ITEMS 8, 19 f 23 Sl-alAL.l. BE RE:QUIRED JUST PRIOR TO Thi:: ACTUAL USI;: OF RECYCLED WATER. • ITE;M 22 THE SIGNAGE Sl-alALL BE A PART OF TI-IIS I.P. BUT Tl-alE ACTUAL SIGNS AND TAGS WLL BE INSTALLED JUST PRIOR TO ACTUAL USE OF RECYCLED WATER. ON RECYCLED WATER SYSTEMS, ALL APPURTENANCES (SPRINKLER HEADS, VALVE BOXES, ETC.) Sl-alALL BE C0LOl<--CODED PURPLE PEl2 AWWA GUIDELINES AND SECTION 16815 OF THE CALIFORNIA HEAL TH AND SAFETY CODE. THEl:!E: SI-IALL BE A PHYSICAL SEPAl2ATI0N BETWe;E:N ADJACENT Al2E:A$ IRIRIGATED WITI--I RECYCLE:□ WATER AND P0TASL.E WATER. SEPARATION SI--IALL BE PROVIDED BY CONCRETE $TRIP$, Cl-alAIN LINK Fl;:NCE$, OR OTl-alER Mi;:ANS AS APPROVl;:D BY THE WA TB.' DISTRICT AND D.E.1-ai. CJ CJ CJ CJ C C CJ CJ CJ NOGLE ONUFER ASSOCIATES ARCHITECTS 2398 Sar"I Diego Ave_ San Diego, CA 92110 TeleJJhan!!: {619) 297-B066 FAX: (619) 297-8055 D•\DWGS\JPM\GP2\GP2-C0V.DWG 3/99 RECYCLED (FUTURE) WATER SYSTEM (PRIVATE) GRAND PACIFIC PALISADES PHASE 2 RESORT SIGNAGE NOTES Carlsbad, THE FOLLOWING SUIDEUNES FOR Tl-I!= USE OF Rf:CYa.E:D WATER ARE TO BE PERMANENTLY POSTED INSIDE THE DOOR OF EACH CONTR0LLE:12 Whl::RE Tl-alEY ARE EASILY VISB..E. PLACE ON 81/2" X Ir SIZED SIGN. COLO!<• PURPLE BACKGROUND WITl-al aACK LRTl;:RING. I, GUIDELINES FOR RECYCLED WATER USE I. I1:!l:!!GATE BE:TWEEN THE HOURS OF 1000 PM AND 6•00 AM ONLY. WATEl21\JG OUTSIDE THE TIME FRAME MUST BE D0I\E MANUALLY WITH QUALl"IED SUPERVISORY PERSONNEL ON-SITE, NO SYSTEM SHALL AT ANY TIME BE LEFT UNA TTIENDED DURING USi;: OUTSIDE Tl-all;: NORMAL SCHEDULE. 2. IRRIGATE IN A MAr,,,,,el:! THAT WILL MINMZE RUN-OFF, POOL.NG, AI\O P0I\OING. 17-E APPLICATION RATE Sl-alALL NOT E:XCEED THE INFILTl<ATI0N RATE: OF THE SOIL. TIME:12$ MUST BE ADJUSTE;D SO AS TO BE COMPATIBLE: WITH THE: l0WEST SOIL INPIL TRA TI0N 12ATE PRESENT. THI$ PROCEDURE MAY BE FACILITATE:□ BY THE: E:FPICIENT SCHEDULING OF THE AUTOMATIC CONTROL CLOCKS, a.E. EMPLOYING THE REPEAT FUNCTION TO Bl<EAK UP THE TOT AL IRl21GA TION TIME INTO CYCLl;:S THAT WILL Pl<0M0TE MAXIMUM SOIL ABSORPTION. S. ADJUST $PRAY 1--lEADS TO ELIMNATE 0VERSPRAY ONTO AREAS NOT UNDER THE CONTROL OF THE CUSTOMER. FOR E:XAMPLE, POOL DECKS, PRIVATE PATIOS AND LOTS, AND STl<EETS AND SIDEWALKS. 4. MONIT0l2 AND MAINTAN THE SYSTE!v1 TO MNMIZE EQUPMENT AND MATEl2IAL FAILURE, BROKEN SPRINKLER HEADS, LEAKS, UNRalABLE VALVES, ETC. SHOULD BE REPAll2ED AS SOON AS THEY BECOME APPARENT. 5. !;:DUCA Ti;: ALL MAINTENANCE PERSONNEL ON A C0NTINOUS BASIS OF THE PRESENCE OF Ri;:CYCLED WATER. PERSONNEL MUST BE 11\FQRl'vED Tl-alA T RECYCL.1;:D WA Tl=R IS MEANT FOR IRRIGATION PUl2P0SES 0NL. Y, AND IS NOT APPROVED FOR DRINKING PIJRPQSl;:S, HAND WASHNG, CLEANING OF TOOL.$, ETC. GIVEN Thi:: HIGH TURNOVER RA TE OF EMPLOYEES N THE LANDSCAPE INDUSTRY, IT IS IMPORT ANT TI--IIS ll'FORMA TION BE DISSEMINATED ON AN ALMOST DAILY BASIS. IT 1$ YOU, THE LANDSCAPE CONTRACTOR WHO IS RESPONSIBLE F012 EDUCATING EA~ AND E!VEl<Y ONE OF YOUR E:MPL0YEE:$. 6. OBTAN PRIOR APPl20VAL OF ALL PROPOSED CHANGES At-0 MODIFICATIONS TO ANY PRIVATE ON-SITE FAOLITIES. SUCH CHANGES MUST BE SUBMITTED TO, AW APPROVED BY, THE DISTRICT ENGIN=ERING OFFICE AND DESIGNED IN ACCORDANCE WITI--I DISTOOT STANDARDS, 7. ALL RECYCLED WATl;:R SPRINKLER CONTROL VALVES SHALL. BE TAGGED WITH IDENTIFICATION TAGS. A. TAGS SHAL.l. BE WEATHERPROOF PLASTIC 3' X 4" PLRPLE N COLOR WITH THE WORDS 'WAl<I\ING RECLAIMED WATER -DO NOT DRl'IK" 111-'?RINTl;:D ON ON= SIDI;:, AND 'NO TOME EL AGUA' ON THE: 0Tl-6! SIDE. IMPRINTNG SHALL BE PERMAI\ENT AND BLACK IN COL.OR, USE TAG AS MANLFACTURED BY T, CHRISTY ENTERPRISES OR APPROVED EQUAL. a ONE TAG Sl-alAL.l. BE ATTACHED TO E:ACH VALVE AS FOLLOW$. I. ATTA~ TO VAL.Ve STEM DIRECTLY OR WITl--l PLASTIC TE-WRAP OR 2. ATTACH TO SOLENOID WIRc: DIRECTLY OR WITH PLASTIC TIE~WQAP OR S. ATTA~ TO VALVE COVEi< WITH E:XISTING VALVE COVER BOLT. 8. ALL SPRINKLER 1-aiEADS SHALL BE IDENTIFED AS Re.CYCLED WATER SPQN(L.e;I:! 1-aiEADS ' II. EACH AUTOMATIC CONTROLLER AND ITS ASSOCIATED l!:CIUPM!'!!NT SHALL Bl! IDl!NTl"'ll!:D WITH A SIGN BEARING THt;: WORDS 'RECYCLED WATER USED FOR IRRIGATION' IN ENGLISH AND SPANISH, WITH BLACK LETTERS I' HIG!-l ON A PIJRPLE BACKGROUND. me SIGN SHALL 8E PLACED SO THAT IT CAN BE READLY SEEN BY ANY OPERATIONS PERS0NN::L UTILIZING THI;: EQUIPMENT. □eCLARATION OF RE:SP0NSIBLE Cl-IA~• I HEl2EBY DECLARE Tl-alAT I AM LANDSCAPE ARCl-allTECT Of'-WORK FOR THS PROJECT, THAT I EXCEl<CISED RESPONSaE Cl--lARGE OVER THE DESIGN OF THIS PR0...ECT AS DEPN:D IN SECTION 6703 OP Tl-alE BUSINESS AND PROPESSI0NS CODE AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERST Al'D THAT THE C>-1:CK OF PROJECT DRAWNGS AND SP!:CIPICA TIONS BY THE CITY OF CARLSBAD AND THE SAN DIEGO COUNTY DIEPARTMENT OF E:NVR0NMENT AL HEAL TH IS CONFINED TO A REVIEW ONLY AND DOES NOT RELIEVE ME, AS LANDSCAPE ARCHTECT OF WORK, OF MY Ri;:SPONSIBLITll;:S FOR PROJECT DESIGN. F'll2M NAME AND ADDRESS• RIDGE LANDSCAPE ARCHITECTS 34072 VIOLET LANTERN, SUITE C DANA POINT, CA 926:29 Ta.E:PHONE NUMBERS• (949) 248-9211 / (949) 248-921!3 FAX REGISTRATION NUMBERS• 2809 EXPll2ATI0N DATES• MAY 31. 1999 DEVEL.OPEi< NAME AND ADDRE:SS• GRAND PACIFIC RESOl<TS, INC. 5050 AVENIDA ENCNAS, SUITE: 200 CARLSBAD, CA 92008 TE=I..EPH0NE "'1.JME!ER• (619) 431-8500 California INSPECTION PROCEDURES I. CITY CONSTI:!UCTION NSPIECTI0N SHALL INCLUDE• A. LOCATION OF PPE UNES. B. TI:!ENCI--I DE!"TI--IS C. REQLJRED SEPAl<ATION 0-IOl<IZ0NTALL.Y AND VERTICALLY) D. PIPE IDENTIFICATION El, P0INTS-0F-GONNlc:CTION <POC'S) F. LOCATION At-0 IDENTFICATION OF SPRINKLER HEADS G. WARr-.,,.JG SIGNS AT THE SITE AND ON THE TRUCKS HAULING RECYCLED WATER Of RECYCLED WATER IS USED FOR C0NSTRIJCTI0Nl. AN APPROVED LETTER REGARDNG THE INSPE:CTI0N OF THE PROJECT SHALL 8E 0BTAINE:D FROM THE CITY AND THE DISTRICT, AND BE F'ORWARDE:D TO THE: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL Hc:ALTH Pl2IOR TO FINAL NSPE:CTI0N APPl20VAL. 2. DISTRICT PNAL INSPECTION SHAL.L. INCLUDE• A. COVl=RAGI;: TESTS, AFTER COMPLETION OF THE SPRNKL.ER SYSTEM. TO DETERMINE THE ADEQUACY OF COVERAGE ON Te£: APPROVED US!;: AREA At-0 PROTECTION OF AREAS NOT APPROVED FOR RECEIVNG RECYCLED WATER. B. WARl',I\JG SIGNS AND LABELS. C. QUICK COUPLING VALVES. D. ALL ASPE:CTS OF THE IRRIGATION COl'DITIONS INCLUDNG WINDBLOWN $PRAY, RUN0PP AND PONDNG. E. REOUl<E:D PR0TIECTI0N OF AL.I.. RESIDENTIAL AREAS. F. REOUl<E:D PROTE;CTI0N Of WELLS, STREAMS, RESERVOIRS, RC. G. CROSS-CONNECTION. s. ANNUAL NSPECTION 81-aiAL.L. NCWDe1 A COMPLRE: INSPECTION ~CH SI-IOULD COVER PAl<TS 'A', "B' AND 'G' OF TI-e DISTRICT FINAL INSPECTION. LEGEND SYMBOi.. DESORPTION ----PW-----Pl20POSED POT ABLE WA TE;R SYSTEM --RW---EXISTING RECYCLED WATER SYSTEM -•-~w-1-PROPOSED IRRIGATION SYSTE:M MAINL.Nt;: AL.I.. LANDSCAPED AREAS ARIEA OF RECYCLED WATE;R US!;: •s "' L.OCA TION Of COI\NECTI0N PONTCSl - rvETER AND BACKFL0W PREVENTION 'DO NOT DRNC' SIGN LOCATIONS TYPICAL SIGNS ~----WHITE LOGO ~----PURPLE BACKGROUND 36' <N.T.5J ~--r WHITE; !..ETTERS WARNING A D WATER DO NOT DRINK RECYCLED WATER ~ 12' X 36' .032 ALI..MNJM SQUARE=~ AVIBO -AGUA IMPUAA NOTOMAR ~--r WHITE LETTE;RS ~--2• WHITE LETTi;:12$ In Ordor i,, C-W•blr- R EC Y CLE D WATER INUN DO NOT ti:\ NO TOME DRINK ~ EL AGUA WASH HANDS AFTER CDITTACTING LAVES£ SUS MANOS D£SPU£S □£ USAR ~· X ~• SIZE P0R AMY, Pt.RPL.e BIG, .032 AU..1\,1., WelTe COPY, SOl.lARE CCJR1',a.!S $1-lEETINDEX SI--IEET TITLE RECYCLED WATER/ TITLE SH=E:T IRIRIGA TI0N PLAN RRIGA TION DETAIL$ e LEGi;:t-0 PLANTING PL.AN PLANTING DETAILS RRIGA TION SPEOFICA TIONS PLANTING SPECIPICATI0NS PALM Tl2EE: AND LANDSCAPE MAINTE;NANCE SPEC'S CROSSOVERS OF RCW AND PW MAIN -RC MAIN TO SE SLEEVED Pc:=< NOTE 16 THIS SHEET CROSSOVERS OF RCW AND PW MAIN -RC MAIN TO BE SLEEVED PER N0.,.E 16 THIS SHEET PROJECT MAP 51-E!::T NUMBEI< I 2 3 4 5 6,7 8 9 NOT TO SCALE: ~ LO I'-- TRACT NO. CT-96-01 UNIT N0.3, LOT 14, MAP N0.13215 \o AVE. VICINITY MAP NOT TO SCALE: ~ APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE ENGIN LOCATION OF PLANTING AREAS. BU IL T'' REVISIONS MUST ElE APPROVED ElY PUElLIC HEAL NGINEER, CITY OF CARLSBAD PLANNING DEPARTMENT I SH~ETS I CARL BAD MUNICIPAL WATER DISTRICT .p,...!!-..IL.l.C!<:::::.+/--F-l-l,,l,CL~--t:l=....1.L-f O:::.:::?.l 15' ?,-~ -'\ "t T ENGINEER DATE ENVIRONMENTAL HEALTH 5 -'-( ...,, APPROVED BY: DATE LANDSCAPE ARCHITECT OF WORK BY: JAMES J. RIDGE NAME: RIDGE LANDSCAPE ARCHITECTS L.A.: REG. NO. 2809 EXP.: MAY 31, 1999 ~k&c1r~ ARCHITECTS TtL 9-111 2.fll-9211 FAX 949 2d 921& REVIEWED BY: INSPECTOR D-'TE ASSIST ANT PLANNING DIRECTOR AND DISTRICT El>JGNEER PRIOR TO IMPLEMENTATION IN FIELD. DATE BY DESCRIPTION REVISIONS -'PP'D RECYCLED WATER / TITLE SHEET GRAND PACIFIC PALISADES RESORT CARLSBAD RANCH HOTEL & TIMESHARE RESORT PHASE 2 OWN BY_--"'='---- CHKD BY_==... __ FIELD BY PROJECT NO. CT 96-01 CMWD u '!C..-50"\ DRAWING NO. 356-7M ~ L4.0 / .· ~ . /·, / .:,,/ . . ./ ',:,,/ • <· ,' ' ~ . ,_,.-.. . X > ,< / ~-~x ////.'Vy /'.',', ... l/4' I ·. __ ., · ... , •.. '\. / X / v X X X X X / / / / MA rcµLINE -SEE PLAN AT i<!Gj::j'f -------------------------------------------------------, ,,, ·' ,. _.,· /' "-'"' ' . ' . / / / / ~',-------c--~----~ NOTE:• \ X 'x .. , X \(/ .• X . X // / X , -1 I I / / / . / '\ I \ \ .•· ,,., I I-"'"' €1---~~/ i . , ·l I I / / / / 47 CONTRACTOR SHALL COIINE:CT VALVES 826 TI-ROUGH 836 TO T..E E)(ISTING CONTROL WRES PROVIDED BY THE PHASE I CONSTk'lJCTION (REFER TO SHEET L4.3 FOR STLE-OUT l.OCA TION), SAID WRES SHALL BE CONNECTED TO THE EXISTNG CONTROl.l.ER 'El" INSTALLED AS PART OF THE PHASE I 12i<IGA TION IMPROVEMENTS. REFER TO SHEET l.4l OF THE PHASE I u;?RIGA TION IMPROVEMENT PLANS FOR THE ACTUAL CONTROLLER LOCATION AND INFORMATION. CONTRACTOR SHAl.l. VERIFY ALL IRRIGATION CONI-ECTION AND DISCONNECTION PONTS IN FELD WITH OWi-ER'S AUTHORIZED 12.EP12ESENTATIVE: PRtOR TO BIDDING AND PRIOR TO CQMM.El')JCING WORK. -.,____.!.-NOTE• . . VALVES 1!!17, 818,821, 82!'1, AND 826 ARE EXISTNG VALVES M PI-IASE: I il<RIGA TION IMPROVEMENTS AND SHALL BE: UTLIZED FOR PHASE l1 IRRIGATION IMPROVEMENTS. \. TRACTOR SHALl.··VERIFY Al.l. IRRIGATION CONI-ECTION Ai'Jq DISCO~ECTION POINTS IN FIELD WITH OWNER'S ·. •. M AUT~ORIZED REPRESENTATIVE PRIOR TO BIDDING AND PRIOR \. TO \MENCING WORK,. . •. ~/. \\. \ ... ~ i. · .. ·... EXIST··.• .. ··· 21/2. • J:?E:'CLAIMW IQRIG. ATIO·· .. N MAINLI\E. VERIFY •. ~ ~•·• :\ SIZE: AND OCATION IN FIELD WITH OWNER'S AUTHORIZED . ·. ··, .. ,... \\ \\ , ·. REPi:!.ESE \;TIVE PRIOR TO COMME,NCNG WORK . ·.. \ ··.. 829 411 • '\, ·.. ' \ ~• I . \\, ··... . \\, ·.. . . ,,.,.....,.._~'tNI!: SHOWN WIT~ PAVING FOR 0..ARITY ONLY, ACT%AL MAINLll'l; l.OCA TION TO Si;:; A MINMUM OF iB" 0 F APJACE:NT HARD.SCAPE: AND OTHER OSSTAO..E:S .. . AND UT OF R1GHT-OF·WA Yi TYP. , ~REFE:~~O NOTE "A" BE:LOW RlGHT .. ·. I '. . .. . . I . . ' eJ<51N; ~, _.,... eo<>iECTN eLAO, t. \ . t I . . . \ l/1 ~ / i1/I' FC" rRbM CUR$ ML., ~A\1\1 CINE . FW =-FRC\M,WAJ .. 1,... ··. " . \i. .. , X ~ / ~ 1· X j .. / I I .. ~ .... .,..c:,.; ' I . '. ---SLEfi:VE' UNDI:~. . ---Co~t..RE'TE . · PONT OF CONNE:CTION V PER APPROVED PL.ANS . FOR THE 'GRAND PACIFIC RESORT' <PHASE D, CMWD 1196-509 I RW0449 NOTE:• ... ···· .. CONTJ:?ACTOR SHALL ADJUST Al'ID CAP OFF EXISTING IRRIGATION SYSTEM IN Tl-IS ARE:A AS RE:CLJIRED. SYSTEM SHAl.l. PROVIDE COMPLETE COVERAGE: AS APPROVED BY OWNER'S AUTHORIZED REPRESENTATIVE. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE ADJUSTMENT/MODIFICATION OF EXISTING IRRIGATION SYSTEM WITHN THIS AND OTHEl2 AREAS AFFECTED BY THE PROPOSE:D IMPROVE:ME:NTS. ALL LAYOUT SHALL BE: CONARME:D WITH OWNER'S AUTH0121ZEO REPQESENT A TIVE PRIOR TO COMl'vlENCING WORK. HEAD l.A YOUT IN THIS AREA IS DIAGRAMA TIC AND SHAL.L .. SE ADJUSTED AS REQUIRED IN FlaD TO PROVIDE: PROPER COVE=RAGI;::, \ \ . \\···· .. . '\ NOTE A• CONTRACTOR SHALL CONNECT Pi<OPOSED 2-1/2" RECLAIIIIED ll<?RIGA TION MAINLINE TO TH.:: EXISITING 2-V2" RECLAIMED ll<?RIGA TION MAINLINE. CONTRACTOR SHAUL VERIFY ALl. IRRIGATION CONI-ECTION AND DISCONNE:CTION POINTS IN FIE:LD WITH OWNER'S AUTl-lORIZE:0 REPRESENTATIVE PRIOR TO BIDDING AND PRIOR TO COMME:NCING WORK. NOTE:• -- CONTRACTOR SHALL ADJUST ALL HEADS AS REQUIRE:□ TO ACCOMODA TE • ANY VE:RTICAL OBSTRUCTIONS THAT MAY OCCUR, INCLUDING BUT NOT LIMITE:D TO LIGHT POLE:S, FIRE HYDRANTS, ETC. VE:RIFY Al.l. HEAD LAYOUT WITH OWI\ER'S AUTHORIZED RE:PRE:SE:NT A TIVE: PRIOR TO COMME:'NCING WORK. CONTRACTOR SHALL VE:RIFY ALL SITE: CONDITIONS, PROPE:RTY LINES, DIME:NSIONS. ETC, PRIOR TO SIDDING AND PRIOR TO COMME:NCING ' ,. ~··········•··•·\,·.~· "' . / ·X ... X I ) ' I 1 .. I I • I RR1ciA.T10N VALVES CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLETE INST Al.LA TION OP PROPOSED IRRtGA TION eau1PMeNT AND RELATED ECUPMENT, INCLUDING BUT NOT LMITED TO R.C.V, CONTROL WIRES, ELECTRICAL WIRES. CONDUIT, REMOTE CONTROL VALVES, ETC. AUL LAYOUT AI\D L.OCA TIONS SHAUL BE CO!'rlRfll'ED WITH OWNER'S AUTHORIZED REPRE:SENTATIVE: PRIOR TO COMME:NCING WORK. WORK, NOTIFY THE OWNER'S AUTHORIZE:D REPRE:SENT A TIVE: IMME:DIATEL Y IF ANY DISCREPANCIE:S ARE FOUND, CONTRACTOR SHALL THOROUGHLY FAMILIARIZE: HIMSE:LF WITl-l ALL SITE: CONDITIONS PRIOR TO BIDDING AND COMMENCING WORK, ·x.. · ..... ·· .... ,., x·· •· ... '· ,~ "'"'/~ /~ l"OR CONTINUATION OF RE:CYCL.E;D WATE;R MAIN, REFER TO SEPAl<ATE: DRAWINGS FOR THE 'GRAND PACIF'IC l:!ESORT' (P~ASE ll, · · SHEET L5.I D•\DWGSIJPMIGP2\GP2-IP.DWG X "' ·. X X X " X . /\ X X X ·--+-"A"'~ E0R .... 1/S.' •,,-.. ..... i 8 114 ... <"I-··· '----0• I I · 3/1', J/4' V I _J < ,ML Fr ~ ... ',SI . ' .. .,,5 ' I' ~ I' "1 I.fl I I t I 11 f 625\10 I \ ANY EXISTING IRRIGATION CONTROL VALVES CONNECTED TO EXISTING CONTROLLER WHICH ARE DISCONNECTED DLRING CONSTRUCTION SHAUL BE RE-COI\NECTED TO i;:;XISTING CONTROl.l.ER. CONFIRM PROPER CONTROLLER OPE:RA TION AND INSTALLATION WITH OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO COMMENCING WORK AND UPON COMPLETTION OF WORK, CONTRACTOR SHALL SE RESPONSIBLE FOR REPAli:2/MODACATION OF ALL ADJACENT IRRIGATION SYSTEM EQUIPMENT THAT IS AFF'ECTED BY PROPOSED IRl:?IGATION IMPROVEMENTS. CONTRACTOR SHALL REPAIR SAID SYSTEMS TO A LIKE NEW MANNER, PROVIDING COMPLETE 100'1 HEAD TO HEAD COVERAGE IN ALL AREAS WITH SYSTEM LAYOUT AS APPROVE=□ SY OWNER'S AUTHORIZED REPRESENTATIVE. CONTRACTOR SHALL CONFIRM ALL AREAS RE:OUIRING MODIFICATION WITH OWNEl2'S AUTHORIZED REPRESENTATIVE PRIOR TO BIDDING WORK AND PRIOR TO COMMENCING WORK, CONTI!ACTOR SI-Wl. BE .?ESPONSB..E FOR T1-lE COMPLETE REMOVAL AN) DISPOSAL OF ALL EXISTING RRIGATION EOL.Pr-lENT Aff'ECTffi BY Tl-lE PROPOcffl IRRIGATIO\I M'ROVEM3'1TS. CONTRACTOO 51-W.L VERFY ALL EOLPM':NT TO BE l<EMQVED AN) DISPOSED OF N FIELD P12100 TO BIDDNG WORK AND PQIOR TO COIIIMENCI\G WORK. X \Sf] I __ .,__.---,-~•s ,,,.,iLALAL LtES ""e SHOWN WITH'< PAVo.G . FOR CLARITY QNL Y L ACTUAL LOCATION TO BE WITHIN PLANTER. I X I 1 BUBBLERS SHALL Bt: ALIGNED WITH TREES AND AS DIRECTED BY. OWNER'S AUTH RIZED REPRESENTATIVE, CONFIRM ALL LAYOUT IN FIELD WIT"1 OWN R'S AUTHORIZE[) REPRESENTATIVE: PRIOR TO COMMENCING WOR • . Sweeney & Associates, Inc. Irrigation D•••an • C.::io.,•1.1•1:tne11 28«1 Rancho Callfornlo Ad. Ito. K t•~••~ T.n-lt(;ull, CA t2S90 ~ ·'. ./\ '.; Q Pt,. 90II-G11$-2317 Fo,. 909,'95-2487, : 0 10 20 40 60 FOR IRRIGATION NOTES e DETAILS' - SEE SI--IEET 3 CL5.D FOR IRRIGATION SPECIFICATIONS .. SEE SI--IEETS 6 e 1 (LB.I e L8.2) APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE /.~ Jj~t,tlt-;~-1-..~i[J' ~// r-----------,--~~-----~-...,....----------------rr-=~~=======~=~ E-tnd: L&COvmicro.corn "' u" 1 t I) t-LOCATION OF PLANTING AREAS. ----- RI D G c LAN DSC A Pl:: ARCHITECTS TEL j49 248-9211 FAX ,949 248 9215 ''AS BUILT'' 12EVISIONSMUSTBEAPPROVEDBYPUBLICHEALTHENGINEER. ISH2EET I CITY OF CARLSBAD ISHE~TSI ASST, PLANNING DIRE:CTOR AND DISTRICT ENGINEER PRIOR TO PLANNING DEPARTMENT , IMPLEMENTATION IN FIELD. ~ 1---+--+----------------+-----J LANDSCAPE IRRIGATION PLAN GRAND PACIFIC PALISADES RESORT PHASE 2 R.C.E. ______ >---+---+----------------------,~==================~ 1------------------+------l-+-------------------1--~ APPROVED ,,-/.~ REVIEWED BY: t-----+--+----------------t------1 ---------<::.:~'t[Y_"""-______ t/_-f ?-7'7 INSPECTOR .---.----,-----------------..------1 ASSISTANT PLANNING DIRECTOR DATE '3, '3C,. 00 f-D_A_TE~B_Y~ ______ OE_S_CR_IP_T_IO_N ------~-AP_P_'D7 DATE REVISIONS DWN BY-~-- CHKD BY_J_I< __ FIELD BY PROJECT NO. CT 96-01 C.M.W.D. #96-509 DRAWING NO, 356-7M • I <tiii) L4.I I ToP OF MULCH 7 LAYER, F.G. +3' =1 11:.:..:1 I I~ mm r ~ ill' ill I" 1111 QUICK COUPU=~1t----~- PUNCH-LOK ----...,, R..ASTIC VALVE BOX (10" W / PURPLE LIDl ~I I 1=1 11':':: r rn rn =m m . Tfl I lml II .......... , ..... . CLAMPS .,..:.: ::.:.:'.:""'. '.'-'-'. '-": '. ::.:.:: '."-'-'. '.'-'-'. '.11---ei::!ASS l<!ISER .................. :~ +II--+-:-:-:-:-:-:-:-:-:-:.:.:•:·:·:->> ............. ............ ,-----SRASS SWING JOINT ASSEMEII.. Y ~---'>f' ;,.,-,...-~MAINLINE: 30' l<EBAI:! ST AKE SCH. 40 PVC TE!:!: NOTE:• QUICK COUPLE:12 FITTINGS Al:!E NOT TO BE INTERCHANGEABLE WITH POTABLE: WATE:12 FITTINGS. QUICK COLPLEQ VAL.VE TO BE: DESIGNED TO BE USED WITH QECLAIMED WATER. @ QUICK COUPLER VAL VE CLE:AN COMPACTc:D ---------, l!IACKP'ILL (2l WARNN(; TAPc:S PAVING. BY OTHE.? -------n1 . :111= UNDISTURBED SOIL---=II -1 I 1-·.·. ·.·. ·.· ·.· . ·.· .. ·.·.· ·. •·· • ~ N 111 LA Tl:RAL LIie IN SLeEVE =1 I , i::: \ ~ SCH. 40 FOQ PEDEST.?IAN PAVING I= < -111 SCH 80 FOR VEHICULAI:! PAVING·--i I \ \ •. · - =1 I 1-1 I 1= /. I tt CONTROL WIRE::S ·= -111= -11 .· · •.. :.....••··•.·••.·•.·•··•.•.· -111= IN SCH 40 SLEE:VES .--_ -_ · ·. ·.-·.-· ... · -·-----· MAINLINE SL.El=VE; SCH 40 UNDER PEDEST.?IAN P i I 1=111 MAINLINE SLEEVE SCH 80 UNDER VEHICLE PAVING =111=1 I I= TAPE CONTROL WIRES TO MAINLINE I 6" I 10 FEET ON CENTER ' " DEPTH AS SHOWN Or;> ON CONCRETE SLAB FOR ON STRUCTURE INSTALLATION. SLEEVES T~UGH WALLS BY OTHERS. • + + + + ' + + + + -+ + + + . + + + + . + + + + + ® SLEEVE INSTALLATION ~ ORAN CM' ~ lvlSSION l<Ufft:R CO. / NO, 0704-0f>. 4" rr"l'lii'F-----FNSI-I GRADE J~~-----B.EB.611-EAO, SEE LEGEM> F'OR SPECl"CA TION TOP r BELOW FNSI-I Gf.1ADE 1-lf"H,i~,------SCH 80 r,f'P\,.e, La\lGTl-l AS REO...l<ED, 2 re<UIED A'-f-~iil------VALCON 1/'Z Mill ORAN VALVE ~----NATIVE SOL u,c,c.=.u.c.., -----PVC LA TEl<AI. L.N!: ----------DRLL ™'10l.GI PIPE ...__ ____ 1/2" PVC ELL($ Tl 'it>-o-------4" ()A 36' LQl,,G l'm"CQA TED PVC D~AN Fff' FU WITH 3/4" G.?Ava TO BOTTOM OF Cl-ECK VALVE ~----------AMl,£NDED BACKFlL ,.___------------ROOT BAU. OF TRB: CD DEEP WATER BUBBLER Sweeney & Associates, Inc. lrrla•·uvn D•••an • c<11n•uH:•n1;11 21"'41 Ronol>o Cllltornlo Rd. ■to. K ~•••"••,._ Temecula, CA 9ffl0 -:. ;; ,;i:, ; Pt!, DOI-IUll-2317 Fax. •0t•Nl-24-87+ • E-mal: LSC@wnk:ito.aom ~ u CJ I t o • D•\DWGS\JPM\GP2\GP2-ID.DWG TOPOl"'~~~l 1 PLASTIC VALve eox =·--------POP-UP SPQINKLEQ HEAD ' a2· W / PUl2PLE' LO) WITH RECLAIME:D WA Tc:R "NP' CAP ~----FINISHED GRADE LAYER, F.G~ TOP FLUSH W/ F.G. IN TURF AREAS TOP 1/2" ABOVE F.G. IN SHRUB AREAS SCH. 80 ~PPLE;, LE;NGTH AS .?EQU~D I MARLEX STRE!ET c:LL AND I PVC T~EADED ELL (90) SCH. 80 NIPPLc: {6' MINIM.JM> MARLEX STREET ELL OUT OF' L.ATERAL LINE: FITTING LA TE:RAL. LINE. DE:PTH AS SPECIFED IN LEGEND HEAP TO BE INSTALLED• 2" FQOM ALL CUi:?BING 4" Fr20M ALL WALKWAYS 12· FROM ALL BUILDINGS AND WALLS @ BALL VALVE @ POP-UP SPRINKLER 1-lEAD Cll;!AN COMPACTaJ ---------, l!!IACKFILL C2l WARNNG TAPES F'LASTIC VAL.VF;. EIOX (12" W/ PURPLE l.lDl FINISHED GRAD~ ,--.,..,...,.-"T"'""l"",,-,,C-"""'_._,, ____ ,.,,C7C-r-T'"'""!'T'T ~1111118 : =12· UNDISTURBED SOIL---=11 :111 = MAN...INE AND CONTROL WIRES TAF'E CONTROL WI~$ TO MAN.INE 10 FEE;:T ON CB\JTER DEPTHS SHOWN AQE: FOR IN GROUND INST AULA TIONS. ON STr:!UCTURE INST ALL PIPING AT DEPTH SHOWN OR AT CONCREaTE SLAB DEPTH. FE:MALE! ADAPc---lf-J SCH. 80 PVC ::~-:~~:~ GRA~~~·-· ...... j'" .. --□ TWO CUBIC FEET RRIGATION WATER MAINL.I\E'------' BRICK SUPPOr:!T . .,,_---------~ @ PIPE INSTALLATION @ REMOTE CONTROL VALVE METE!:! BOX Wt l\ti'=TEl2 --------, SIDEWALK I Cl.RB i --24" ==-i APPROX. 8 12" MINIMUM POTABLE 61!:RVICE Ll'Jfe--------1 STREET SURFACEi~---~I F'OTAl!ILE MAINLlf\E'------~ (SEE IMPROVEMENT DRAWINGS) I 12" MINIMUM REQUIRED VERTICAL SEPARATION NQre, SLE:EVE i<ECLAIMED WATER IRRIGATION MAINLlf'.E W/ SLEE:V NOTE• VERTICAL CLEARANCE OF 12" MINIUMUM IS MANDA TOl2Y WI-EN Cr:!OSSING PATH OF A POTABLE WATEl2 LINE. INSTALLATION OP' r:!ECLAIMED WATER RRIGATION MAINLINE 24' FROM FACE OF SIDEWALK WLL Pl2OVIDE THE NECESSAl:!Y 10' HORIZONTAL CLEA12ANCE Fl2OM POT ABLE MAINL.INE IN THE STREET. AL.L RECL.AIM!=D WATER IRRIGATION PPlr-G AND SLEEVES SHALL BE PLQPLE AND LABELED AS SPECIFIED IN• CG) POT ABLE SERVICE LINE CROSSING IRRIGATION NOTES "STANDARD SPECIFICATIONS FOR PRIVATE IRRIGATION SYSTEMS' "CARLSBAD RECLAMATION 12ULES AND REGULATIONS FOR CONSTRUCTION OF RECLAIME:D WATE:R MAINS' OCTOBEl2 1993 @ POT ABLE MAINLINE CROSSING ALL LOCAL MUNICIPAL AND STATE LAWS, RULES AND REGULATIONS GOVERNING OR RELATING TO ANY PORTION OF THIS WORK ARE HEREBY INCORPORATED INTO AND MADE A PART OF THESE SPECIFICATIONS AND THEIR PROVISIONS SHALL BE CARRIED OUT BY THE CONTRACTOR. 2 THE CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES, STRUCTURES AND SERVICES BEFORE COMMENCING WORK. THE LOCATIONS OF UTILITIES, STRUCTURES AND SERVICES SHOWN IN THESE PLANS ARE APPROXIMATE ONLY. ANY DISCREPANCIES BETWEEN THESE PLANS AND ACTUAL FIELD CONDITIONS SHALL BE REPORTED TO THE OWNER'S REPRESENTATIVE. 3 THE CONTRACTOR SHALL OBTAIN THE PERTINENT ENGINEERING OR ARCHITECTURAL PLANS BEFORE BEGINNING WORK. 4 THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS REQUIRED TO PERFORM THE WORK INDICATED HEREIN BEFORE BEGINNING WORK. 5 THIS DESIGN IS DIAGRAMMATIC. ALL EQUIPMENT SHOWN IN PAVED AREAS IS FOR DESIGN CLARITY ONLY AND IS TO BE INSTALLED WITHIN PLANTING AREAS. 6 DO NOT WILLFULLY INSTALL ANY EQUIPMENT AS SHOWN ON THE PLANS WHEN IT IS OBVIOUS IN THE FIELD THAT UNKNOWN CONDITIONS EXIST THAT WERE NOT EVIDENT AT THE TIME THESE PLANS WERE PREPARED. ANY SUCH CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE PRIOR TO ANY WORK OR THE IRRIGATION CONTRACTOR SHALL ASSUME ALL RESPONSIBILITY FOR ANY FIELD CHANGES DEEMED NECESSARY BY THE OWNER. 7 INSTALL ALL EQUIPMENT AS SHOWN IN THE DETAILS AND SPECIFICATIONS. CONTRACTOR SHALL BE RESPONSIBLE TO COMPLY WITH LOCAL CITY, COUNTY AND STATE REQUIREMENTS FOR BOTH EQUIPMENT AND INSTALLATION. El ACTUAL LOCATION FOR THE INSTALLATION OF THE BACKFLOW PREVENTER AND THE AUTOMATIC CONTROLLER IS TO BE DETERMINED IN THE FIELD BY THE OWNER'S AUTHORIZED REPRESENTATIVE. 9 CONTRACTOR IS TO PROVIDE AN ADDITIONAL PILOT WIRE TO THE END OF THE MAINLINE RUN IN TWO DIRECTIONS FROM THE CONTROLLER. 1 D ALL PIPE UNDER PAVED AREAS TO BE INSTALLED IN A SLEEVE TWICE THE DIAMETER OF THE PIPE CARRIED, ALL WIRE UNDER PAVED AREAS TO BE INSTALLED IN A SLEEVE THE SIZE REQUIRED TO EASILY PULL WIRE THROUGH. ALL SLEEVES SHALL BE SIZED AND INSTALLED WITH A MINIMUM DEPTH AS SHOWN ON THE SLEEVING DETAIL (DETAIL E, SHEET 3 (L5.1 )). SLEEVES TO EXTEND AT LEAST 12" PAST THE EDGE OF THE PAVING. ALL SLEEVES TO BE AS SHOWN ON THE PLANS. 11 ALL QUICK COUPLER VALVES TO BE INSTALLED IN SHRUB OR GROUND COVER AREAS WHERE POSSIBLE. ALL QUICK COUPLER VALVES TO BE INSTALLED AS SHOWN ON THE INSTALLATION DETAILS. INSTALL ALL QUICK COUPLER VALVES WITHIN 18" OF HAR0SCAPE. 12 ALL HEADS ARE TO BE INSTALLED WITH THE NOZZLE, SCREEN ANO ARCS SHOWN ON THE PLANS. ALL HEADS ARE TO BE ADJUSTED TO PREVENT OVERSPRAY ONTO BUILDINGS, WALLS. FENCES AND HARDSCAPE, THIS INCLUDES, BUT NOT LIMITED TO, ADJUSTMENT OF DIFFUSER PIN OR ADJUSTMENT SCREW. REPLACEMENT OF PRESSURE COMPENSATING SCREENS, REPLACEMENT OF NOZZLES WITH MORE APPROPRIATE RADIUS UNITS AND THE REPLACEMENT OF NOZZLES WITH ADJUSTABLE ARC UNITS. SYMBOL Q T H F ... ---_.__ (!l ~ e, • <, ~ e • Cl <9 e Ell "' ,., ,, 'v I:,. • ..d:,_ V w 1" w ['3 l'3 E3 B3 ~ ~ l""I ■ El I.ii @ '@'@ Q) "@' ® G) c6 ® @ @' (]J) NOT SHOWN NOT SHOWN - -------- NO SYMBOL NO SYMBOL NO SYMBOL NO SYMBOL NO SYMBOL NO SYMBOL • MANUFACT. RAIN BIRD RAIN BIRD RAIN BIRD RAIN BIRD RAIN BIRD RAIN BIRD RAIN BIRD RAIN BIRD RAIN BIRD RAIN BIRD RAIN BIRD RAIN BIRD RAIN BIRD HUNTER HUNTER HUNTER HUNTER RAIN BIRD HUNTER NIBCO NELSON RAIN BIRD AS APPROVED AS APPROVED AS APPROVED AS APPROVED AS APPROVED IRRIGATION MATERIAL LEGEND MODEL NO, / DESCRIPTION 1806-SAM-NP-10-LA-PCS-020/030/040 POP-UP SHRUB HEAD 1612-SAM-NP-10-LA-PCS-040/060/090/175 POP-UP SHRUB HEAD 1612-SAM-NP-12-PCS-060/090/125/260 POP-UP SHRUB HEAD 1812-SAM-NP-15-PCS-090/125/175/370 POP-UP SHRUB HEAD 1812-SAM-NP-15EST/SST-PCS-060/125 POP-UP SHRUB HEAD 1806-SAM-NP-SF-B-PCS-040 STREAM BUBBLER 1806-SAM-NP -PA-80-1408 PRESSURE COMPENSATING BUBBLER EACH SYMBOL REPRESENTS TWO BUBBLERS PER TREE. 1806-SAM-NP-SQ-B-PCS-040 STREAM BUBBLER EACH SYMBOL REPRESENTS TWO BUBBLERS PER TREE. 1806-SAM-NP-10-LA-PCS-020/030/040 POP-UP TURF HEAD 1806-SAM-NP-10-LA-PCS-D4D/D60/090/175 POP-UP TURF HEAD 1806-SAM-NP-12-PCS-D60/090/125/260 POP-UP TURF HEAP 1806-SAM-NP-15-PCS-090/125/175/370 POP-UP TURF HEAD 1806-SAM-NP-15EST/SST-PCS-06D/125 POP-UP TURF HEAD PGP-ARV/3RV-02/05/0B PDP-UP TURF ROTOR HEAD PGP-ARV/3RV-03/06/09 POP-UP TURF ROTOR HEAD PGP-ARV /3RV-04/07 /10 PDP-UP TURF ROTOR HEAD PGP-ARV /3RV-05/08/ll POP-UP TURF ROTOR HEAD GPM .20,.30,.40 .39,,52,. 79, 1.57 .65,.87, 1,3,2.6 .93, 1.23, 1.85,3.7 .61,1,21 0.40 2,0 (4.0) 0.40(.80) .20,.30,.40 .39,.52,. 79, 1.57 ,65,.87, 1.3,2.6 . 93, 1.23, 1 .85,3. 7 .61,1.21 .B,1.8,3.7 1.0,2.4,4.9 1.4 ,3.0,6.0 1.8,3.7 ,8.0 PSI RADIUS 30 5 FT 30 10 FT 30 12 FT 30 15 FT 30 4X15 FT 30 3FT 3D 6 IN. 30 6 IN. 30 5 FT 30 10 FT 30 12 FT 30 15 FT 30 4X15 FT 40 25 FT 40 30 FT 40 35 FT 40 40 FT ALL SPRAY HEADS INSTALLED 10 FEET OR MORE FROM PAVING SHALL BE PA-BS HEADS WITH THE NOZZLES AS SHOWN HCV SERIES ADV, TO BE INSTALLED ON ALL SPRINKLERS HEADS WITH LOW HEAD DRAINAGE T-580-70 BRONZE BALL VALVE, LINE SIZE , 2" MAX #7645 QUICK COUPLER VALVE, INSTALL INSIDE A 1 0" ROUND VALVE BOX QUICK COUPLERS INSTALLED MAXIMUM DISTANCE OF 1 DO FT ON CENTER FOR THE ENTIRE LENGTH OF THE MAIN LINES PES-13-PRS SERIES PLASTIC PRESSURE REDUCING DRIP REMOTE CONTROL VALVE, SIZE AS SHOWN RECLAIMED WATER PVC PIPE 3/4" -3" CL. 200 AS LATERAL LINES 12" BELOW GRADE PIPING SHALL BE COLOR CODE'.D PURPLE AND MARKED AS INDICATED IN RECLAIMED WATER NOTES, SEE SHEET T-1 RECLAIMED WATER PVC PIPE 21/2" CL. 315 AS MAINLINES 24" BELOW GRADE, ALL PIPING SHALL BE COLOR CODED PURPLE AND MARKED AS INDICATED IN RECLAIMED WATER NOTES, SEE SHEET T-1 EXISTING RECLAIMED WATER PVC PIPE 21/2" CL. 315 />S MAINLINES 24" BELOW GRADE. RECLAIMED WATER PVC PIPE SCH. 80 AS SLEEVING UNDER VEHICULAR PAVING, TWICE THE DIAMETER OF PIPE OR WIRE CARRIED PLACE BELOW ALL PAVING, HARDSCAPE, ETC., AND PS DIRECTED BY OWNER'S AUTHORIZED REPRESENTATIVE. PIPING SHALL BE COLOR CODED PURPLE AND MARKED AS INDICATED IN RECLAIMED WATER NOTES, SEE SHEET T-1 DETAIL A A A A A A A A A A A A A A A A A N/A N/A B G D E E E BUNDLE F RECLAIMED WATER PVC PIPE SCH. 40 AS SLEEVING UNDER PEDESTRIAL AND PRIVATE DRIVEWAY PAVING, TWICE THE DIAMETER OF PIPE E,F OR WIRE BUNDLE CARRIED. PLACE BELOW ALL PAVING, HARDSCAPE, ETC., AND AS DIRECTED BY OWNER'S AUTHORIZED REPRESENTATIVE. PIPING SHALL BE COLOR CODED PURPLE AND MARKED AS INDICATED IN RECLAIMED WATER NOTES, SEE SHEET T-1 AS APPROVED IRRIGATION CONTROL WIRE #14UF AWG DIRECT BURIAL (U.L. APPROVED) J,K E RAIN BIRD ST-03 GREY "SNAP-TITE" WIRE CONNECTORS AND PT-S5 SEALER AS APPROVED ALL VALVE BOXES SHALL BE PURPLE COLOR CODED AND MARKED AS INDICATED IN RECLAIMED WATER NOTES, SEE SHEET T-1 N/A AS APPROVED ALL VALVES SHALL HAVE RECLAIMED WATER ID TAGS INSTALLED AS INDICATED IN RECLAIMED WATER NOTES. SEE SHEET T-1 N/A N/A AS APPROVED AU. CONTROLLERS SHALL HAVE RECLAIMED WATER PLACARDS INSTALLED AS INDICATED IN RECLAIMED WATER NOTES, SEE SHEET T-1 APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. '' AS BU IL T'' REVISIONS MUST BE APPROVED BY PUBLIC HEAL TH ENGINEER. ASST. PLANNNG DIRECTOR AND DISTRICT ENGINEEl2 Pl2IOR TO IMPLEMENTATION IN FIELD. CITY OF CARLSBAD PLANNING DEPARTMENT RI D G E LANDSCAPE ARCHITECTS TEL 949 248-9211 FAX 949 248 9215 R.C.L ____ _ REVIEWED BY: INSPECTOR DATE R.C.E. ----~- DATE BY DESCRIPTION APP'D DATE REVISIONS LANDSCAPE IRRIGATION DETAILS GRAND PACIFIC PALISADES RESORT PHASE 2 APPROVED ~---f'-12-99 ASSISTANT PLANNING DIRECTOR DATE OWN BY-~'--- CHKD ey_J~l2 __ FIELD BY PROJECT NO. CT 96-01 C.M.W.D. #96-509 DRAWING NO. j. 356-7M @ii) L5.I ' / / y ' / _.; .... ·-,, . ' ',• ,\. D·\DWGS\JPM\GP2\GP2-PP.DWG / ~--,,_ ' _:,,.--i_ .......... 3~ X . . G.,2 , 20'BiH T-5 , • + / ) I • RESTAURANT • • 3 T-2 + " . " " "' . _,.;. .. "' "' . : \ I I \ I \ I PLANT LEGEND SYMBOL NO, BOTANICAL / COMMON NAME TREES 0 T-1 NERIUM OLE:ANDER 'SISTE:R AGr-ES' / OLEANDER ~ T-2 PI-JOENIX DACTYLIFERA / DATE; PALM • 0 0 Sf-RLES 0 0 0 $ EB 111111 I! I I 1111 0 0 • 0 0 VIN!=S T-3 TIPUANA TIPU / TIPU TREE' T-4 T-5 S-1 S-2 S-3 S-4 S-5 S-6 5-7 S-8 S-9 S-IO V-1 TRIST ANIA CONFERT A / BRISBANE BOX WASHINGTONIA R0BLJSTA I ME;XICAN FAN P Al.M BOUGAINVILLEA 'RASPBERRY ICE' I BOUGAINVILLEA DIETES BIC0L0R / BUTTERFLY IRIS LANT ANA CAMARA I BUSl-4 LANT ANA TEC0MARIA CAPE:NSIS / CAPE 1-40NEYSUCKLE UGUSTRUM JAPONICUM "TEXANUM' / TEXAS PRIVET TRAC~LOSPERMUM JASMIN00ES / ST AR JASMINE CARISSA M. 'GREEN CARPET / NATAL PLUM RAPi.l0LEPIS "MAJESTIC BEAUTY'/ INDIA HAWTHORN STREUTZIA REGINAE / BIRD OF PARADISE PHORMUM TENAX 'A TROPURPL.REUM' I NEW ZEALAND FLAX CL YTOSTOMA CAWSTEGI0IDES / VIOLET TRUMPET VII\E GROUND COVERS I I . . .. . . . ... . v~ Hflliffl TURF G-1 ANI\L.JAL COLOR G-2 TRACHELOSPERMJM JASMINOIDE;S/ ST Alo? JASMII\E G-3 VNCA MINOR / DWARF PfcRIWINKLE GT-I MAl.'ATI-ON Ill SOD GT-2 'AGRONO-TEC' HYDOOSEED BALLFIELD MIX =2A SIZE I SPACING 24' BOX 24' Bi<OWN TRLJNK HEIGHT 24' BOX 24' BOX 30' BROWN TRIJNK I-EIGHT OR AS SI-I0WN 5 GAL / 36' 0,C, 5 GAL / 36' 0.C. I GAL./ 36' 0.C. 5 GAL / 36" O.C. 5 GAL / 30' 0.C, I GAL. / 18' 0,C. I GAL. / 3' O.C. 5 GAL. I 4' 0.C, 5 GAL. 5 GAL. 5 GAL. STAKED 4' POTS I GAL. / 18' O.C, FLA TS / 12' 0.C. EXISTING PLANT MA TEl<IAL CPI--IASE D SYMBOL NO. BOTANICAL I COMMON NAME EXISTING Ti.?EES .', ET-I ERYTHRINA COl.?ALL0IDES I ET-2 .. ET-3 /~ ET-4 )( ET-5 ET-6 NAKED CORAL Tl2EE TIPUANA TIPU / TIPU Tl2EE NERIUM OLEANDER 'SISTER AGNES' / OLEANDER l"H0ENIX DACTYLIFEl.'A / DATE PALM PYRUS CALLERY ANA 'CHANTICLEER' / 012NAMENT AL PEAR WASHINGTONA R0BUSTA / MEXICAN FAN PALM EXISTING SHRUBS O· CTI ~ + / / >:; ES-I ACHILLEA TA YGE'TEA 'MOONSHINE' / NON ES-2 AL Y0GYNE ~LH / BLUE HIBISCUS ES-3 BOLGAINVLLEA 'RASPBERRY ICE' I BQL,GAINVU.EA ES-4 DIETES BIC0L012 / BUTTERFLY IRIS ES-5 JLJSTICIA Blo?ANDEGEANA / SHRIMP PLANT ES-6 LANTANA CAMARA/ BUSH LANT ANA ES-7 LAVANDLJ...A ANGUSTIFOLIA / ENGLISH LAVENDEl2 ES-8 TEC0MARIA CAPENSIS / CAPE HONEYSUCKLE ES-9 LIGUSTRUM JAP0NICUM 'TEXANUM' / TEXAS Pi<IVET ES-10 PITT0SPORUM T0Bll.'A 'Cl.'E:ME DE MNT / DWARF VARIEGATED TOBIRA ES-II RAPHOLEPIS INDICA 'BALLERl'JA' / NDIA HAWTI-I0l<N ES-12 1.'0SA 'SMALL MIRACLIE' I NCN ES-13 CAl<ISSA M. 'Gi<EEN CAl<i"ET' I NATAL PLUM ES-14 RAPHIOLEPIS 'MA..ESTIC BEAUTY' / INDIA HAWTHORN TURF CALCULATIONS TOT AL LANDSCAPE AREA • 23,200 S.F. PEl:?MANENT TURF AREA • 848 S.F. (3.71) TEMPORARY TURF AREA • 4,599 S.F. (19.81) TURF AREA <P~ASE ll• • 3,981 S.f. •NOTE• NEW TURF ON ARMADA DRIVE IS INCLUDED AS A MODIFICATION TO T~E GRAND PACIFIC RESORT. P~ASE I. RESULTING IN A NET DECREASE IN TURF AREA ON T~AT PROJECT FROM 4.51 OP THE TOT AL LANDSCAPE AREA TO 2.9:t. NOTES1 .,,--j------'<-~--t--EXISTING PLANTING WITHIN RIGHT-OF-WAY, PER DWG NO. 92-503. TO BE PROTECTED IN PLACE. • INST ALL JUTE NETTING AND CITY APPROVED FLATTED GROUND COVER AT 12" O.C. ON SLOPES Wl-llCl-l EXCEED 6=1 GRADIENT. RI D C E I_ AN D'.:iC A Pt: ARCHITECTS TE( HI ~-9211 FAX 9◄9 141 1215 '' AS BU IL T'' DATE R.C.E, ----- 0 10 20 40 60 • FOR PLANTING NOTES e DETAILS SEE Sl-lEET 5 {L 7.D • FOR PLANTING SPECIFICATIONS SEE S1-lEETS 8 E 9 (L8.3 E L8.4) APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. REVISIONS MUST BE APPROVED BY PUBLIC HEALTH ENGINEER, I SH4EET I CITY OF CARLSBAD I SHE!TS I ASST. PLANNING 011.?ECTOR AND DISTRICT ENGINEEl2 PRIOR TO PLANNING DEPARTMENT , IMPLEMENTATION IN FIELD. ;:===:.:::::============:.:::::=cc:::c::; LANDSCAPE PLANTING PLAN GRAND PACIFIC PALISADES RESORT PHASE 2 R,C,E, _____ 1---1--+-----------------+-----1 ~~~~=====;;::;,:::=-;;--:=========::::::; 1-----------------+--+--+----------------+-----1 APPROVED (./,·····/?. ::;-//-(; REVIEWED BY, _X/ 1£/ 1/"-IZ-77 INSPECTOR t---t--+-------------~--+----1 ASSISTANT PLANNING DIRECTOR DATE BY DESCRIPTION APP'O OWN BY-~-----1---~+-----------------+-----1 CHKD BY__;J:;.;.R __ PROJECT NO. CT 96-01 DATE REVISIONS FIELD BY C.M.W.D. #96-509 DATE QRAWING NO. 356-7M L6.I - PLANTING NOTES A. REFER TO PLANTIIJG SPECIFICATIONS AI\D DETAILS FOR SOL PRE!PARATION, F"el2TILIZATION, MULCHNG AND OTHER PLANTING NFOi:?MATION. B NOTIFY OWNE:;R'S AUTHORIZW REPRESENTATIVE 48 I-IOL..RS PRIOR TO COMME:NCEMENT OF WOl:!K TO COOQONA TE; PROJECT INSPECTION SCHEDLLE;S. C. VEl21A' ALL EXISTING CONDITIONS, DIMENSIONS AND l!LEVA TIONS BEFORE PROCeEDING WITH T..E WORK. NOTIFY LANDSCAPE ARCHITECT IMMEDIATELY SHOULD FIELD CONDITIONS VARY FROM THOSE SHOWN ON Pl.AN. D, REPORT DISCREPANCIES N THE Dt:?AWINGS OR E!l!:TWl!!l!!N THE DRAWINGS AND ACTUAi.. Fll'!I..D CONDITIONS TO TI-E LANDSCAPE ARCHITECT. CORRECTED DRAWNGS OR INSTRUCTION SHALL Bl!!: ISSUED PRIOR TO THE CONTINUATION OF THIS WORK. ASSUME FULL RESPONSBLITY FOR ALL NECESSARY CORRECTIONS DUE TO FAILURE TO REPORT KNOWN DISCREPANCIES. E. LOCATE ALL EXISTING UTLITIES WHETHER SHOWN HEREON OR NOT AND PROTECT THl!!M FROM DAMAGE. NOTIFY OWNEl2'S REPRESENTATIVE MMEDIA TEL Y AND ASSUll,E FULL RESPONSBLITY FOQ EXPENSE OF REPAIR OR REPLACEMENT IN CONJUNCTION WITH DAMAGED UTILITES. F. LOCATION OF N.1.C. CONSTRUCTION ELE'ME'NTS SUCH AS LIGHTS, SIGNS, VE:NTS, 1-fl'DRANTS, TRANSFORMERS, ETC. ARE APPROXMA TE. NOTIFY THE LAl'IDSCAPE ARCHITE:CT IMMEDIATELY SHOULD THE LOCATION OF THESE ITEMS INTERFERE WITH THE PROPEl2 EXECUTION Of WORK. G. OBTAIN ALL SOIL FOR LANDSCAPE PLANTING Ai:?EAS OR BERMS FROM ON-SITE EXCAVATIONS, SHOULD IMPORT SOIL BE N=CESSARY, SUBMIT IMPO.?T SOIL TESTING RESULTS FOR APPROVAL PRIOR TO IMPORTATION. SOIL SHALL BE SANDY LOAM CONT AINI\IG NO TOXIC CHE:MICALS OR ELEMENTS WHICH MAY INHIBIT OR RETARD NOOMAL PLANT GROWTH. H. AFTE::R ROUGH GRADE::$ HAVE BEEN ESTABLISHE::D N PLANTING AREAS, HAVE SOIL SAMPLES TAKEN AT THI:: LOCATIONS IIJDICATED BY DESIGNATION ~ . HAVE SAM"LES TESTED BY SOIL AND PLANT LAB, {714) 558-8333, FOR SOIL FERTILITY, AGRICULTURAL SUIT ABILITY TEST AND SOL PREPARATION RECOMMENDATIONS. TAKE TWO SAMPLES AT EACH LOCATION, (D GROUND LEVEL TO IO' DEEP, {2) 24" TO 36" DEEP. EACH SAIVPLE SHALL CONTAIN APPROXIMATELY I OUART OF SOIL, TO BE LABELE:D PER LOCATION AND DEPTH. INSTALL SOL PREPARATION AND BACK FILL MIX TO CONFORM TO THESE RECOMIIAENDA TIONS ONLY UPON RECEIPT Of WRITTceN CHANGE ORDER FROM OWNER. CITY IIJSPECTOR MUST APPROVE SOIL TEST RECOMENDA TIONS Pl.'!Oi:1 TO AMENDING SOL Sl.Bv11T SOIL REPORT TO LANDSCAPE ARCHITECT PRIOR TO PLANTING, L KL.L. AND Rf;:MOVE ALL EXISTING WEEDS FROM SITE: ARE::AS PER SPECIFICATIONS. J, ASSURE POSITIVE DRAINAGf;: IN ALL PLANTING ARE;AS, 21 MINIMUM. K. LOCATE; AND TAG ALL PLANT MA TE:RIAL, MA TE;RIAI. SHALi. BE: IN COl',f'ORMANCE WITH PLANTING PLAN DESCl.'IPTIONS AND $PE;CIF"ICA TIONS. ALL PL.ANT MA Tf;:RIAL IS SUBJECT TO REVIEW AND APPROVAL PRIOR TO INSTALLATION. PROVIDE PHOTOS OF REPRE:SE:NTATIVE E;XAMPLES OF E:ACH TAGGED BLOCK TO l.ANDSCAPf;: ARCI-ITE:CT MII\IMLM 21 DAYS BEFORE: ANTICll"ATE:D DELIVf;:RY. PHOTOS SHALL NCLUDE A PERSON FOR SCALE PURPOSES. I.ANDSCAPE: ARCHITECT MAY OF'T TO Rf;:VEW MA TE:RIAL AT GROWING NURSERY. MATERIAL DELIVERED TO THE SITE MAY BE REJECTED BASED ON UNHEALTHFUL APPf;:ARANCf;: OR NON CONFORMANCE WITH SPECFICA TIONS, EVEN IF PREVIOUSLY REVIE:WED BY THE LANDSCAPE ARCHITECT OR OWNER. L. Al.l. TREES WITHIN A SPECES SHALL HAVE MATCHNG FORM. M. FINAL LOCATION OF' ALL PL.ANT MATE:RIALS SHALL BE: SUBJf;:CT TO THE APPROVAi. OF' T~ OWNER'S AUT~IZED REPRESENTATIVE. N. PLANTNG QUANTITES ARE GIVEN FOR CONVENENCE ONLY. F'LANT SYME!OLS AND SPf;:CIFIED SPACING SHALL TAKE PRECE;DE;NCE::, O. AT EDGES OF PLANTING AREAS, THE CE!NTE!R Llr-.E OF THI!: LAST ROW Of SHRLBS AND / OR GROUND COVER SHALL BE LOCATED NO FARTI-ER FROM THE EDGE THAN 0Nf;:-HALF' THE SPECIFIED ON-CENTER SPACNG. P. INST ALL GROUND COVER AND / Oi:1 SHRUB MASSES WITH Tl.'IANQULAR SPACING UNLe:5S OTHBNYISE INDICATED. Q, ALL TREES WITHIN 6' OF F'AVNG CNOT INCLUDNG PAI.MS) TO i.?ECEIVE TREE ROOT BIAlll:!11!:'!I.', BY DEf;:F' ROOT CORPORATION (714) 898-0563. R. ALL CURVE TO CURVE; AND CUi:?VE TO T ANGE!NT LINES SHALL E!E: Ne:A T, TRIM, SMOOTH AND UNIFORM. S. REMOVE ALL NLRSE!RY ST AKES AND E:SPALl6? RACKS IMME:DIA TEL Y AF'TER INSTALLATION LPON PROVIDING Sl..PPORT PER PLAN. T, LIST ON THf;: PLANT MATE:RIAL GUARANTE:E ALL EXISTING TREES THAT HAVE HAD WORK PERFORMED WITHIN 6' OF TRUNK. U. DURING THE LENGTH OF THE GUARANT!!:E PEl.'IOD, BE RESPO>SEILE FOR F'i<!OF'Ei:2 STAKII\G AI\D / OR GUYING OF TREE:$ TO E:':NSURE ST ABILITY. V. ANNUAL COLOR TO Be SELECTED BY LANDSCAPE ARCI-IT~T AT TIMI'! OF INSTALLATION. REQUEST RECOMlvENDATION A MINIMUM OF 48 HOUl.'S IN ADVANCE OF NEf;:D FOR DELIVERY. W. MULCH AI.L LANDSCAPE AREAS (E:':XCLUDING TURFl HAVING LE::SS THAN A 3•1 SI.OPE WITH A~• DEEP LAYER OF 'MEDIUM GRIND MULCH' SLPPLIED BY MICHAl=L. RAWL.S COMPANY (714) 633-3666 AT TI-E CONCLUSION OF Pl.ANTING OPf;:RA TIONS, SUBMIT SAMPI.E TO CITY INSPECTOR FOR APPROVAL PRIOR TO BL.LK DELIVERY TO SITE:. EROSION CONTROL NOTES SLOPES REQURING EROSION CONTROL lvt:ASLRES AS SPECIF'eO 1-eR~N SHALL l!lE TREA Tl!D WITH ON= OR MORE Of Tl-€ FOLLOWING PLANTING STANDARDS• A STANDARD 1:11 -COYER CRDP I JUTE iYESH COVER CROP SHALL BE A SEW MIX TYPICALLY MADE: UP OF QUICK Gl15!MINA TNG Ai',O FAST COVERING GRASSES, CLOVERS, AND/ OR WILD fLOWs:?S. SUBIINT THE SPECIAC SEED MIX FOi.! CITY APPROVAL Pl.'IOR TO APPLICATION. THE COVER CROP SHALL BE APPL.IE:□ AT A RATE: AND MAN\ER SUFFICIENT TO PROVIDE 901 COVERAGE WITHIN H-IRTY (30) DAYS, TYPE OF JUTE MESH SHALL BE AS APPROVED BY THE CITY AND STAKED TO THE SLOPE AS Rf;:COM\4ENDED BY THE MAN..FACTURE:R. .J.JTE MESH SHALL BE REOLJl<l!':D WHEN PLANTING OCaJRS BETW!!!e!N ALJGILIST l!5 AND APRIL 15. DLQ11\G THI!! RE':MAN)f3;? OF THI! YEAR, THE COVl!:R CROP AND / OR JUTE MESH MAY BE US!!:D. II. STANDARD 1:12 -GQOl.ND COY!!!R ON!: HUNOReD PERCENT CIOO'&l OI" THI! ARl'!A SHALL Bl!: PLANTl!D WITH A SROUIO COvei.? KNOWN TO HAVf;: EXCELLENT SOL BN'.>NG CHARACTEl.'ISTICS (PLANTED FROM A MNMUM SIZE OF FLATTED MATERIAL AND SPACED TO PROVIDE FULL COVERAGE WITI-IN 0Nf;: Yf;:ARJ, C. ST AWARD ■3 • LOW S1,QLBS LOW SPREADING WOODY SHRU!l5 (F'LANTED P'l20M A MNMJM OF 2-3/4 NCH LN5!Sl SHALL COVER A MNMUM OF SEVENTY PERCENT (701) OF TI--E SLOPE FACE CAT MATURE SIZE), D. STAWARD 1:14 -TREES AND / PR l ARGE SHRUBS TREES MO / OR LARGE Sf..l.!L0S SHALL BE PLANTED (Fi:20M A MNMUM Of I GALLON CONTAN::RS) AT A MNM.JM RATE OF ONE: (I) Pl.ANT PER TWO ..UNDRED (200) SQUARE FEET. Al.I. SI.OP!$ 3•1 OR STEEPEIZ AND 4' TO 8' N VERTICAL HEIGHT .?E'OURE: ST ANDRADS "I, "2 AND 1:13, SLOPES OVER 8' N VERTCAL I-EIGHT REOL.11.'E STANDARDS ■I THROUGH ,,4. COVER seeo C.?OP COMPOSITION TO BE:• DESCFi!f'TICJN ESCHSCHOLZIA CALF~A LUPNUS SUCCU..ENTUS O'CONNOR'S LEGLM= FIBER MULCH 16-16-16 Ff;:RTILIZER ST A8LIUZI\G BINDS! 0•\DWGS\JPM\GP2\GP2-PD.DWG 2 2 20 2000 400 120 LEGEND H/2 • IIOl'.lTIIAU. ,_,.. ----- L 2>(II00'1"8AIJ. l q \l¥DTl-l \ I. BULDNG WALL. l"E!NCE OR TR!!!LLIS PER PLAN 2. WATEl2 BASIN-MN 4' DEl"TH. REMOVE BASIN Al"TER MAINTENANCE l"E:RIOD 3, FNISHED GRADE. 4, AMENDED BACKFILL MX-SEE SPECIFCATIONS, TAMP OR WATE:R SE:TTLE: SO PLANT DOES NOT SINK AFTER PLANTNG 5. Ff;:RTILIZING TABLETS, SEE Sl"ECIFICA TIONS 6, ROOTBALL OF PLANT-MUST NOT BE ROOTBOUI\D, LOOSEN ANY TIGHT-PACKE:D ROOTS 7. EXISTII\G SOL. 8. "CROWN" OF PLANT M.JST NOT 8E BlRt!!:D 91'!:LOW LEVEL OI" SURROUNDING SOIL 9, EPOXY TIE W/ GRee!N i'j_JRSl!:RY TAPE -SEClJ.<E LEADER TO TRELLIS POST, SECURE ALL OTHs:? LENGTHY BRANCHING TO TRELLIS IN AN OUTWARD RADIAL PATTERN WITe-J NURSERY TAPE, VINE PLANTING - \~!l=;=;ttimtt:t---13 -- 1·1 rn ··.·~ II 1-- IJ l.EGIE;ND• I, FINISH GRADE OF GROUNDCOVER 2, FIIJISH GRADE OF TURF 3, 2 X 4 RE:DWOOD HEADERBOARD 4. IX 3 X 16" .?E:DWOOD STAKES o 5' O.C., PLACE:D ON GROUNDCOVE.? SIDE: AND Pl.ACE:□ BELOW TOP OF HEADERSOARD NOTES• A. SPLICES TO BE! I X 4 X 12" ReDWOOD B. NAILS TO l3E GALVANIZED COMMON NAILS. NAIL AS REQUIRED FOR SOLID INSTALLATION. C. Hf;:ADf;:RBOARD SHALL BE: LAID TRUE: TO LINE: AND GRADE, REDWOOD 1-lEADER E ] SECTION LE:Gf;:ND I, LOCATE PLANTS WITH EQUAL SPACING AS INDICATED ON PLAN, TRIANGULAR SPACNG 2. 24" CLEAR Vf;:HICLE OVERHANG ZONf;: LOW (MAX. 8" HT.l GROUNDCOVER ONLY. 3, CURB 4. SPRINKLER HEAD -NO e-llGH POP-UPS ~. VEHCLE PLAN VIEW 6, V2 SPACNG FOi.! SPECFE:D PLANT MATEl.'IAL PLANTING c PARKING ST ALLS 4 I ® w 8 b (() LEGEl'O I. FRON::lS TO BE TIED AND PROTECTED DURNG SHIPMENT. LMIE F'RONDS AFTER 30 DAYS. OR AS Dli:.11::CTED BY PALM TREE E:XPERT OR LAI\DSCAPE ARCHITf;:CT. 2. TRUNK HEIGHT• MEASURED FROM OOIGINAL Gi:?ADE LEVEL AT BASE OF TRLNK TO TERMNAL BUD AT BASE OF FRONDS. TRUNK TO BE: CLEAN. STRAIGHT AND FREE OF' SCARS OR ROT. SET TRLJI\K PLUMB VERTICAL 3. PLANT BASE OF TREc: AT QI,! SI.IGHTL Y ABOVE FINSH GRAD(;:, DO NOT BURY ANY PART OF TRUNK 4, FINISH Gl.!ADE 5. i:200T8ALL• TO 8E Pl.!OTECTED DURING SHflME':NT MINMUM 3'-6'X 3'-6"X 4· DEEP. 6. 6" MINIMJM 7. WASHED COARSE CONCRETE SAND BACKALL. DO NOT USE EARTH OR CTI-ER TYPE:S OF SAND. 8, CONCRETE: CIJo?B PER CIVIL ENGINE:ER'S DRAWINGS 9. 2" THICK DECOIVPOSED GRANT!!! MULCH 10, 6" DIA. 8LACK PVC SLIP CAP, TOP 3" MAX, 11. SOLID 6' PVC PIPE 12. TREVIRA 115127 ON BOTTOM AND SIDES (I.F 6" 11111TH PEGSl 13, 12' DIA, X 8' DEEP AUGURED HOLE FLLED WITH 3/4' CRUSHED GRAVEL 14. 6" DIA. X 8' PERFORATED PVC PIPE -CENTER IN HOLE 15, END CAP 16. 4" PE.?FO.?A TED PVC DRAN...NE: {CENTERED L.f\DER PALM BALL) NOTE, SEE PALM TREE PLANTNG AND MAINTENANCE SPECIFICATIONS FOR ADDITIONAL REOLJl;>EMENTS PALM PLANTING l rouAL. L ~ " NOTES A. ALL SHRUBS/~OUND COVERS SI-W..L BE PLANTE:□ AT EOUAL SPACING (TRIANGUL.ARJ UNLESS OTHERWISE: IIJDICATED ON PLANS. SEE LEGEND FOR SPACING RE!OUIREMENTS. S~RUB / GROUND COVER SP ACING LEGEND L ONf;: THROUGH FFTEEN GALLON CONT AINf;:1<! SIZf;: PLANT 2. WATER BASIN-MIN. 4' DE:PTH. REMOVE BASIN AFTER MAINTENANCE PERIOD 3. FINISHf;:0 GRADE. 4. AMENDED BACKFILL MIX-SEE SPECIFICATIONS. TAM" OR WA~ SETTLE SO PLANT DOES NOT SINK AFTEI.! PLANTING 5, FERTILIZING TABLETS. SEE SPECIFICATIONS 6. ROOTBALL OF PLANT-MUST NOT BE ROOTBOUND, LOOSEN ANY TIGHT-PACKED ROOTS 7, EXISTING SOIL 8. 'CROWN' OF PLANT MUST NOT 8E BURleD BELOW LEVE!L OF SURROUNDING SOIL S~RUB PLANTING J.-==_.J. PLAN VIEW LEGEND I. 24" CORDED Tlf;:. Sf;:f;: SPECIF'ICA TIONS. ATTACH WITH ROOFING NAILS <4 TYP.l. 2. 2' DIA. X IO' LODGE POLE PINE ST AKE C2 TYP.l KEEP CLEAR OF ROOTBALL. SEE SPECIFICATIONS. 3. WATER BASIN. 3" MIN. DEPTH AF'TER WATERING BY HOSE, REMOVE BASIN IN LAWN AREAS AND AS Di;?ECTED BY LANDSCAPE ARCHITECT. 4. FINISI--ED GRADE. 5, AMENDED BACKFLL. SE:E SPECIFICATIONS FOR MIX AND PIT SIZE. 6. 21 GRAM PLANT TABLET. SEE SPECIFICATIONS. 7, E:XISTING SOL 8. SCARFY SIDES AND BOTTOM OF PLANTING PIT 9, ARBOR-GARD TRU\K P.?OTECTOR FOR USE IN TURF Ak'E'AS 10. SET TOP OF .?OOTBALL 3" ABOVE SU~OUNDING GRADE: AND Sil.OPE FOR DRAINAGE. IL INSTALL 1tU824-21200T BARRIER PER PLAN AS MGF'D BY OEf;:P ROOT CORP, (714) 898-0563. NOTE1 NONE RE;OUIRED, NOTE• MAINTAIN TURF 3" CLEAR FROM TREE TRUNK, TREE PLANTING/STAKING -15 G./24" B. ' APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. '' AS BU I LT'' REVISIONS MUST BE APPROVED BY PUBLIC HEAL TH ENGINEER, ASST. PLANNING DIRECTOR AND DISTRICT ENGINEER PRIOR TO IIVPLEMENT A TION IN FIELD. CITY OF CARLSBAD PLANNING DEPARTMENT LANDSCAPE PLANTING DETAILS & NOTES RI D ~ E LANDSC PE ARCHITECTS TEI. 149 248-1211 r.u HI 248 121s R.C.E. ____ _ REVIEWED BY: INSPECTOR DATE R,C,E. _____ _ □ATE BY DESCRIPTION APP 1D DATE REVISIONS GRAND PACIFIC PALISADES RESORT PHASE 2 APPROVED P~~ECTOR ASSISTANT f'-12-f..,"? DATE OWN BY PROJECT NO. DR.WING NO. .R CHKD BY CT 96-01 356-7M FIELD BY C.M.W.D. #96-509 L7.I SECTION 02811 LANDSCAPE IRRIGATION NOTE; CONTRACTOR SHALL BE FAMILIAR ~TH CARLSBAD MUNICIPAL WATER DISTRICT'S IRRIGATION SPECIFICATIONS AND IN CASES OF CONFLICT BETWEEN THESE SPECIFICATIONS AND CMWD'S SPECIFICATIONS, CMWD'S SPECIFICATIONS WILL TAKE PRECEDENCE. PART I -GENERAL 1 .01 SUMMARY A. It is the intent of the specifications ond drowings thot the flni,hed system is complete in every respect and shall be ready for operation sotisfoc\ory to the Owner. B. The work sholl include all materiols, lobar, services, transportation, and eQulpment necessary to perform the work as Indicated on the drawings, in these speclfico\lon, and as necessary to complete the contract. 1.02 CONSTRUCTION DRAWINGS A. Due to the scale of the drawings, it is not possible to Indicate all offsets, fittings, sleeves, etc. which moy be required, The Contractor shall carefully investigate the structural and finished conditions offecting all of his work and pion his work accordingly, furnishing such fittings, etc. as may be required lo meet such conditions. Drawings are generally diograrnmotic and indicative of the work to be installed. The work shall be installed in such o manner as to avoid conflicts between irrigation systems, planting, and architectural features. B. All work coiled for on the drawings by notes or details shall be furnished and installed whether or not specifically mentioned in the specifications. When an Item is shown on the plans but not shown on the specifications or vice verso, it shall be deemed lo be as shown on both. The Landscape Architect shall have final authority for clarification. C. The Contractor shall not willfully Install the Irrigation system as shown on the dMwings when it is obvious in the fleld that obstructions, grade differences or discrepancies in area dimensions exist that might not have been considered In engineering. Such obstructions or differences should be brought to the attention of the Landscape Architect as soon as detected. In the event this notification is not performed, the Irrigation Contractor shall assume full responsibility for any revision n ecessory. 1.03 QUALITY ASSURANCE A. Provide al least one english speaking person who sholl be present ot all times during .,,ecu\ion of this portion of the work ond who shall be thoroughly familiar with the type of materials being installed and the manufacturer's recommended methods of Installation and who shall direct oil work performed under this section. 8, Manufacturer's directions and detailed drawings sholl be followed in oll coses where the manufacturer of articles used in this contr□ct furnish directions covering points not shown in the drawings and specifications. C. All local, municipal and stole laws, rules and regulations governing or relating to any portion of this work are hereby incorporated into and mode o part of these specifications, and their provisions shall be carried out by the Contractor. Anything contained in these specifications shall not be construed to conflict with ony of the above rules and regulations of the some, However, when these specifications and drawings call for or describe materials, workmanship, or construction of o better quality, higher standard, or larger size than is required by the above rules and regulations, the provisions of these specifications and drawings shall take precedence. D. All materials supplied for this project shall be new and free from any defects. All defective materials shall be replaced immediately at no additional cost to Owner. E. The Contractor shall secure the required licenses and permits including payments of charges and fees, give required notices to public authorities, verify permits secured or arrangements mode by others affecting the work of this section. 1.04 SUBMITTALS A, Materials List: 1. After award of contr,,cl and before any Irrigation system materials are delivered to the job site, submit to the Owner o complete list of all Irrigation systems, materials, or processes proposed to be furnished and installed as port of this contract. 2. Show manufacturer's name and catalog number for each item, furnish complete catalog cuts and technical data, furnish the manufacturer's recommendations as to the method of installation. 3. No substitutions will be allowed without review ond approval by the City and prior written acceptance by the Landscape Architect or Owner's authorized . represen ta live. 4. Manufacturer's warranties shall not relieve the Contractor of his llablllty under the guarantee. Such warranties shall only supplement the guarantee. 8. Substitutions: If the Irrigation Contractor wishes to substitute any equipment or materials for those equipment or materials listed on the irrigation drawings and specifications he may do so by providing the following information ta the City and the Landscape Architect or Owner• authorized representative for approval. 1. Provide a written statement indicating the reason for making the substitution. 2. Provide catalog cut sheets, technical data, and performance information for eoch substitute Item. 3. Provide in writing the difference in installed price If the item is accepted. 1 ,05 EXISTING CONDITIONS A. The Contractor shall verify and be familiar with the locations, •ize and detail of points of connection provided as the source of w<>ler, electrical supply, and telephone line connection to the irrigation system. 8. Irrigation design Is based on the available static water pressure shown on the drawings. Contractor shall verify static water on the project prior to the start of construction. Should a discrepancy exist, notify the Landscape Architect and Owner's authorized representoti,e prior to beginning construction. C. Prior to cutting into the soil, the Contractor shall locote all cables, conduits, sewer septic tanks, and other utilities as ore commonly encountered underground and he shall toke proper precautions not to damage or disturb such improvements. If a conflict e,ists between the such obstacles and the proposed work, the Contractor shall promptly notify \he Landscape Architect and Owner who will arrange for relocations. The Contractor will proceed in the same manner if a rack layer or any other such conditions ore encountered. D, The Contractor shall protect all existing utilities and features ta remain on ond adjacent ta the project site during construction. Contractor shall repair, ot his own cost, all damage resulting from his operations or negligence. E. The Irrigation Contractor shall coordinate with the General Controclor for installation of required sleeving as shown on the plans, 1.06 INSPECTIONS A. The Contractor shall permit the Land•cope Architect ond Owner's outhori2ed representative to visit and inspect at all times any part of the work and shall provid• safe access for such visits. In addition, the City Inspector will ask for o preconstruction meeting and periodic inspections. 8. Where the specifications require work to be tested by the Contractor, it shall not be covered over until accepted by the Londscope Archit .. ct, Owner's authorized representative, and/or governing agencies. The Contractor shall be solely responsible for notifying the Londscope Architect, Owner, and governing agencies, a minimum of 48 hours in advance, where and when the work is ready for testing. Should any work be covered without testing or occeptonce, it shell be, if so ordered, uncovered at the Contractor's expense. C. Inspections will be required for the following at a minimum: 1. Sleeving 2. System loycut 3. Pressure test of irrigation main line (Four hour9 at 125 PSI or 120" of 5tatlc water pressure, which ever is greater). 4, Coverage test of irrigation system. 5. Final inspection prior to start of maintenance period 6. Final acceptance D. Site observations and testing will not commence without the record drawings as prepared by the Irrigation Controetor. Record drawings must complete and up lo date for each site visit. E. Work which falls testing and Is not occ.,pted will be retested, Hourly rates and expenoeo of the Landscape Architect, Owner's authorized representative, and governing agencies for reinspeetion or retesting will be paid by the Irrigation Contractor at no additional expense to Owner. 1.07 STORAGE AND HANDLING A. Use oil means necessary to prot.,ct Irrigation system materials before, during, and after installation and to protect the installation work and materials of all other trades. In the event of damage, immediately make all repairs and replacements necessary to the acceptance nf the Landscape Architect and Owner and at no additional cost to the Owner. B. E•ercise core in handling, loading, unloading, and storing plastic pipe and fittings under cover until ready to install. Transport plastic pipe only on o vehicle with a bed long enough to allow the pipe to lay flat ta avoid undue bending and concentrated external load, 1.0l'l CLEANUP AND DISPOSAL A. Dispose of waste, trash, and debris In accordance with applicable lows and ordinances and as prescribed by authorities having jurisdiction. Bury no such waste material and debris on the site. Burning of trash ond debris will not be permitted. The Contractor shall remove and dispose of rubbish and debris generated by his work and workmen at frequent intervals or when ordered to do so by the Owner's authorized representative. 8. At the time of completion the entire site will be cleared of tools, equipment, rubbish and debris which shall be disposed of off-site in a legal disposal oreo. 1.09 ru RN OVER ITEMS A. Record Drawings: 1. Record accurately on one set of controct drawings all changes in the work constituting departures from the original contract drawings. 2. The changes ond dimensions shall be recorded in a legible and workmanlike manner to the satisfaction of the owner. Prior to final inspection of work, submit record drawings to the Landscape Architect or Owner's authorized representative. 3. Dimensions tram/ta permanent points of reference such as buildings, sidewalks, curbs, etc. shall be shown. Dato on record drawings shall be recorded on a day to day basis as the project is being installed. All lettering on drawings shall be minimum 1/B inch in size. 4. Shaw locations and depths of the following items: a. Point of connection (including water meters, bockflow preventers, master control valves, etc.) b. Routing of sprinkler pressure lines (dimensions shown at o maximum of 100 feet along routing), including sleeves far pipe and wire. c. Boll valves d. Automatic remote control valves e, Quick coupling valves f. Routing of control wires g. Irrigation controllers h. Related equipment (as may be directed) 5. Maintain record drawings on site at all times. Upon completion of work, tran•fer ell os-built information and dimensions to reproducible sepia prints. B. Controller Charts: 1. Record drawings must be approved by Landscape Architect and/or Owner's authorized representative before charts are prepared. 2. Provide one controller chart for each automatic controller, Chart shall show \he area covered by the particular controller. 3. The chart is to be a reduced copy of the actual "record" drawing. In the event the controller sequence is not legible when the drawing is reduced, it shall be enlarged to a readable size. 4. When completed and approved, the chart shall be hermetically sealed between two pieces of plastic, each piece being a minimum 20 mils in thickness. C. Operation and Maintenance Manuals: 1. Two individually bound copies of operation and maintenance manuals shall be delivered to the Landscape Architect or Owner's authorized representative at lea•t 10 calendar days prior to final inspection. The manuals shall describe the material Installed and the proper operation of the system. 2. Each complete, bound manual shall include the following information: a. lnde• sheet stating Contractor's address and telephone number, duration of guarantee period, list of equipment including names and addresses of local manufacturer representatives. b. Operating and maintenance Instructions for all equipment. c. Spore parts lists and related manufacturer information for all equipment. D. Equipment: 1. Supply as a part of this contract the fallowing items: a. Two (2) wrenches for disassembly ond adjustment of each type of sprinkler head used in the irrigation system. b. Three 30-inch sprinkler keys for monuol operation of control valves. c. Two keys far each automatic controller, d. Two quick coupler keys with a 3/4" bronze hose bib, bent nose type with hand wheel and two coupler lid keys. a. One valve box cover key or wrench. f. One 5-faot tee wrench far op.,roting gate valves 3 inches or larger (if used). g. Six e,tra sprinkler heads of each size and type. 2. The above equipment shall be turned over to Owner's outhorl,ed representative at the final inspection. 1.10 A. COMPLETION At the time of the pre-maintenance period inspection, the Landscape Architect, Owner's authorized representative, ond governing agencies will Inspect the work, and if not accepted, will prepare a 11st of items to be completed by the Contractor. At the time of the post-maintenance period or final inspection the work will be reinspected and final acceptance will be in writing by the Landscape Architect, Owner's authorized 8. C. D. representative, and governing agencies. The Owner's authorized representative shall have flnol authority on all portions of the work. After the system hos been completed, the Contractor shall instruct Owner's authorized representative in the operation and maintenance of the irrigation system and shall furnish a complete set of operating and maintenance instructions. Any settling of trenches which may occur during the one-year period following acceptance shall be repaired to the owner's satisfaction by the Contractor without any additional expense to the owner. Repairs shall include the complete restoration of all damag" lo plonling, paving or other improvements of any kind as a result of the work. 1.11 GUARANTEE A. The entire sprinkler system, including all work done under this contract, shall be unconditionally guaranteed against all defec;\s and fault of material and workmanship, including settling of backfilled areas below grode, for a period al one (1) year following the filing of the Notice of Completion. Should any problem with the irrigation system be discovered within the guarantee period, it shall be corrected by the Contractor ot no additional expense to owner within ten (10) calendar days of receipt of written notice from Owner. When the nature of the repairs as determined by the Owner constitute an emergency (i.e. broken pressure line) the Owner may proceed ta make repairs at the Contractor's expense. Any and all damages to existing improvement resulting either from faulty materials or workmanship. or from the necessory repoirs to correct same, shall be repaired to the satisfaction of the owner by the Contractor, oll o\ no additional cost to the Owner. 8. Guarantee shall be submitted on Contractors own letterhead as follows: Port 2.01 GUARANTEE FOR SPRINKLER IRRIGATION SYSTEM We hereby guarantee that the sprinkler irrigation system we hove furnished ond installed is free from defects In materials and workmanship, and the work has been completed in accordance with the drawings and specifications, ordinary wear and tear and unusual abuse, or neglect excepted. We agree to repair or replace any defective material during the period of one year from date of filing of the Notice of Completion and also to repair or replace any damage resulting from the repairing or replacing of such defects at no additional cost to the owner. We shall make such repairs or replacements within 10 calendar days following written notification by the owner. In the event of our failure to make such repairs or replacements within the time specified ofter receipt of written notice from owner, we authorize the owner lo proceed to hove said repairs or replacements made at our expensB ond we will pay the costs ond charges therefore upon demand, PROJECT NAME: PROJECT LOCATION: CONTRACTOR NAME: ADDRESS: TELEPHONE: SIGNED: DATE: II -MATERIALS SUMMARY Use only new materials of the manufacturer, size and type shown on the drawings and specifications. Materials or equipment installed or furnished that do not meet Landscape Architect's, Owner's, or governing agencies standards will be rejected and shall be removed from the site at no expense to the Owner. 2.02 PIPE A. Pre,,ure ,upply line from point of connection through backflow prevention unit shall be Type K "hard" copper pipe. B. Pressure supply line installed over structure shall be Type K "hard" copper pipe. Copper pressure supply line installed over structure shall be secured to the concrete slab using Architect approved fasteners. C. Pressure eupply line• 2 inches in diameter and up to 3 Inches in diameter downstream of backflow prevention unit shall be Class 315 solvent weld PVC. Piping shall conform to ASTM 02241. D. Pressure supply lines 1 1/2 Inches in diameter and smaller of the backflow prevention unit shall be Schedule 40 solvent weld PVC conforming to ASTM D1785. E. Non-prHsure lines 3/4 inches In diameter and larger downstream of the remote control volve shall be Closs 200 PVC, Non-pressur" lines 1/2 inch in diameter ,.hall be Closs 315 PVC. Non-pressure piping shall conform to ASTM 02241. F. Reclaimed water PVC pipe to be color coded "purple" in color and marked on two sides with reclaimed water warning statements "CAUTION -RECLAIMED WATER" in English ond Spanish. Refer to the Carlsbad Municipal Water District requirements on sheet 1 (L-0.0) for further Information. Reclaimed woter piping must be accepted by the local reclaimed water governing agencies. Reclaimed water PVC pipe shall use standard Sch. 40 PVC fittings. Reclaimed water PVC pipe to be Brownline "Alertline' or equol, G. 2.03 A. B. C. D. 2.04 A. B. C. D. E. F. 2.05 A. B. C. D. 2.06 A. B. C. D. Reclaimed water copper pipe to be installed with color coded warning tape In color and marked with reclaimed water warning statements "CAUTION -RECLAIMED WATER" in English and Spanish. Refer to the Carlsbad Municipal Waler District requirement on sheet 1 (L-0.0) for further information. Reclaimed water piping must be occepted by the local reclaimed water governing agencies. METAL PIPE AND FITTINGS Brass pipe sholl be 85 percent red brass, ANSI, IPS Standard 125 pounds, Schedule 40 screwed pipe. Bross fittings shall be medium brass, screwed 125-paund class. Copper pipe shall be "hard" Type K. Copper fittings shall be soldered type, PLASTIC PIPE ANO FITTINGS Pipe shall be marked continuously with manufacturer's name, nominal pipe size, schedule or class, PVC type and grode, Notionol Sanitation Foundation approval, Commercial Standards designation, and date of extrusion. All plastic pipe sholl be extruded of an improved PVC virgin pipe compound ,n accordance with ASTM D2241 or ASTM D 17B4. All PVC fittings shall be standard weight Schedule 40 and shall tie injection molded of on Improved virgin PVC fitting compound. Slip PVC fittings sholl be the "deep socket" bracketed type. Threaded plastic fittings shall be Injection molded. All tees and ells shall be side gated. All fittings shall conform to ASTM 02466. All threaded nipples shall be standard weight Schedule 80 with molded threads and shall conform to ASTM 01785. All solvent cementing of plastic pipe and fittings shall be a two-step process, using primer and solvent cement applied per the manufacturer's recommendations. Cement shall be of a fluid consistency, not gel-like or ropy, Solvent cementing shall be in conformance with ASTM 02564 and ASTM 02855, When connection is plastic turn with a strop wrench. equal. to metal, female adopters shall be hand tightened, plus one Joint compound shall be non-lead base Teflon paote, tape, or BACKFLOW PREVENTION UNITS The bockflow prevention unit shall be of the manufacturer, size, and type indicated an the drawings. The bockflow prevention unit shall be installed in accordance with the requirements set forth by local codes. The backflow prevention assembly shall consist of brass piping, unions and fittings. Backflow preventer enclosure shall be of the manufacturer, size, and type indicated on the drawings. Enclosure shall be constructed af 3/16" stainless steel cmgle stock with 1-1/2" Na. g expanded metal panels and a 3/8" U-bolt lock to be secured to the concrete mounting pad. VALVES Boll Valves: 1. Ball valves shall be of the manufacturer, size, and type indicated on the drawings, 2. Boll valves shall be double union design, Sch. 80 PVC blocked, with Teflon boll seats. End connector carrier and stem are to have either EPDM or Viton 0-rings. Boll valves ore lo hove threaded connections. 3. All boll valves shall hove a minimum working pressure of not less than 125 psi and shall conform lo AWWA standards, Quick Coupler Valves: 1. Quick coupler valves shall be of the manufacturer, size, and type indicated on the drawings. 2. Quick coupler valves shall be brass with o wall thickness guaranteed to withstand normal working pressure of 150 psi without leakage. Valves shall have 3/4 female threads opening ol base, with two-piece body. Valves to be operated only with a coupler key, designed for that purpose. Coupler key is inserted into valve and a positive, watertight connection shall be mode between the coupler key and valve. Hinge caver shall be the lacking type constructed of brass with a rubber-like vinyl cover. Automatic Control Valves: 1. Automatic control valves shall be of the manufacturer, size, and type Indicated on the drawings. 2. Autornotic control valves shall be electrically operated. Anti-drain Valves: 1. Anti-drain valves shall be of the manufacturer, 5,ze, and type indicated on the drawings. 2. Anti-drain valves .shall hove 18-B stainless steel springs and valve sterns with Buna-N seals. 3. Anti-droin valves will hove threaded connections the size of the riser or pipe they are to be installed onto, or the next available size. Na s1·,p connection anti-drain valves ore allowed. CONTINUED ON FOLLOWING SHEET APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. '' AS BU IL T'' REVISIONS MUST BE APPROVED BY PUBLIC ~EAL T~ ENGINEER, ASST. PLANNING DIRECTOR AND DISTRICT ENGINEER PRIOR TO IMPLEMENTATION IN FIELD, CITY OF CARLSBAD PLANNING DEPARTMENT I SH9~TS I DATE R.C.E. RI D G ~ LANDSCAPE REVIEWED BY, ARCHITECTS TEL U9 2-18-1211 FAX 949 2-18 121, PATE BY DESCRIPTION APP'D INSPECTOR PATE REVISIONS LANDSCAPE IRRIGATION SPECIFICATIONS GRAND PACIFIC PALISADES RESORT APPROVED ASSISTANT OWN BY CHKP BY flELD BY PHASE 2 ~$ -=--__ __.lf121f PLANNING K'-' Ji<' DIRECTOR PROJECT NO. CT 96-01 DATE DRAWING NO. 356-7M I C.M.W.D. #96-509 L8.I SECTION 02811 LANDSCAPE IRRIGATION (cont'd) Port II -MATERIALS (cont'd) 2.07 VALVE BOXES A. Valve bo,es shall be fabricat"d from a durabl", W11olher-resistont plo•tic material resistant to sunlight and chemical action of soils. B. The valve box cover shall be purple in color, secured with bolts and marked with reclaimed water warning statements "CAUTION -RECLAIMED WATER" in English and Spanish. Refer to the Carlsbad Municipal Water District requirement on sheet 1 (L-0.0) for further information. Reclaimed water valve boxes must be accepted by the local reclaimed water governing ogencies. C. The cover and box shall be capable of sustaining a load of 1,500 pounds. D. Valve bo• e•tenslans shall be by the same manufacturer as the valve box. E. Automolic control valve boxe• shall be 16"•11"x12• rectongular size. Valve box covers shall be "heat bronded" in 2• high letters "RCV" with the valve identification number. F. Ball valve, flush valve, master valve and quick coupler valve boxes shall be 1 o" circular size. Valve box covers shall be "heat branded" in 2" high letters with either "BV", "FV", "MV" or •ocv"'. 2.06 AUTOMA11C CONTROLLER Automatic controller shall be of the manufacturer, size, and type indicated on the drawings. 2.09 ELECTRICAL A. All electrical equipment shall be NEMA Type .3, waterproofed far exterior installations. B. All electrical work shall conform lo local codes and ordinances. 2.10 LOW VOLTAGE CONTROL WIRING A. Remote control wire shall be direct-burial AWG-UF type, olze as Indicated on the drawings, and in no case smallt1r than 14 gouge. B. Connections sholl be either epoxy-sealed packet type or Penn-lite connectors. C. Ground wires shall be white in color. Control wires shall be red (where two or more controllers are used, the control wires shall be a differentcolor for each controller. These colors shall be noted on the "Record Drawings' plans located on controller door). D. Provide a 24" long expansion loop for all directional changes in control wire routing. 2.11 IRRIGATION HEADS A. Sprinkler heads and drip emitters shall be of th11 manufacturer, size, type, with radius of throw, operating pressure, and discharge rate indicated on the drawings. B. Pop-up heads and riser heads shall be used as indicated an the drawings, Par\ Ill -EXECUTION 3.01 SITE CONDITIONS A. Inspections: 1. Prior to all work of this ••ction, carefully inspect the Installed work of all other trades and verify that all such work is complete to the point where this installation may properly commence. 2. Verify that irrigation system may be installed in strict accordance with all pertinent codes and regulations. the original design, the referenced standards, and the manufacturer's recommendations. B. Discrepancies: 1. In the event of discrepancy, Immediately notify the Landscape Architect or Owner's authorized representative. 2. Do not proceed with installation in areas of discrepancy until all discrepancies have been resolved. C. Grades: 1. Before starting work, carefully check all grades to determine that work may safely proceed, keeping within the specified material depths with respect to finish grade. 2. Final grades shall be accepted by the Engineer before work an this section will be ollowed ta begin. D. Field Measurements: 1. Make all necessary meaeurements in the field ta ensure precise fit of items In accordance with the original design. Contractor sholl coordinate the installation of all irrigotion materials with all other work. 2. All scaled dimensions are opproximate. The Contractor shall check and verify all size dimension• prior lo proceeding with work under this section. .3. Exercise extreme core in e,covoting and working near e,isting utilities. Contractor shall be responsible for damages to utilities which are caused by his operations neglect. E. Diagrammatic Intent: The drawings ore essentially diagrammatic. The size and location of equipment and fi,tures ore drown to scale where possible. Provide offsets in piping changes in equipment locations as necessary to conform with structures and to ovoid obstructions or conflicts with other work ot no additional expense to Owner. F. Layout: 1. Prior to instollation, the Contractor shall stake out all preo•ure supply lines, routing ond location of sprinkler heads, volve,o, backflow preventer, and outornotic controller. 2. Layout irrigation system and make minor adjustments required due to differences between site and drawings. Where piping is shown on drawings under paved oreas, but running parallel and adjacent to planted oreos, install the piping in the pion led areas. G. Water Supply Connections to, or the lnatallotlon of, the water supply shall be at the locations shown on the drawings. Minor changes caused by actual site conditions shall be mode at no additional expenae lo Owner. H. Electrical Service: 1. Connection• to the electrlcol supply shall be at the locations shown on the drawing•. Minor ch<mge• cou,ed by site conditions shall be mode ot no odditionol expense to Owner. 2. Contractor shall make 120 volt connection to the irrigation controllers. Electrical power source to controller locations shall be provided by others. .3.D2 TRENCHING A. Excavotions shall be straight with vertical sides, even grade, and eupport pipe continuously on bottom of trench. Trenching excavation shall fallow layout indicated an drawings to the depths below finished grade and as noted. Where lines occur under paved area, these dimensions shall be considered below subgrade. B. Provide minimum cover of 18 inches on pressure supply lines 2 inches and smaller, or as available when installed over structure. C. Provide minimum cover of 18 inches for control wires, or as available when installed over structure. D. Provide minimum cover of 12 inch11s for non-pressure lines, or as avallable when installed over structure, F. Pipes Installed In a common trench shall have a 6 Inch minimum space between plpee. 3.03 BACKFILLING A. Backfill moteriol on oil lines shall be the some cs adjcc11nl soil free of debris, litter, and rocks aver 1 /2 inch in diameter. B. Backfill shall be tamped In 4-inch layers under the pipe and uniformly on both sides for the full width of the trench and the full length al the pipe. Bock/Ill materials shall be sufficiently damp to permit thorough compaction, free of voids. Back/Ill shall be compacted to dry density equal to adjacent undisturbed soil and shall conform ta adjacent grades. C. Flooding in lieu of tamping ls not allowed. D. Under no circumstances shall truck wheels be used to compact bockflll. E. Provide sand backfill a minimum of 6 inches aver and under all piping under paved creos. 3.04 PIPING A. Piping under existing pavement may be Installed by jacking, boring, or hydraulic driving. No hydraulic driving Is permitted under asphalt pavement. B. Cutting or breaking of existing povement is nat permitted. C. Carefully inspect oil pipe ond fittings before installation, removing dirt, scale, burrs reaming. Install pipe with all markings up for visual inspection ond verification. D. Remove all denied and damaged pipe sections. E. All lines shall have o minimum clearance of 6 inches from each other and 12 inche• from lines of other trades. F. Parallel lines shall not be installed directly over 9ach other. G. In solvent welding, use only the specified primer and solvent cement and make oil Joints in strict accordance with the manufacturer's recommended methods including wiping all excess solvent from each weld. Allow solvent welds at least 15 minutes setup time before moving or handling end 24 hours curing time before filling. H. PVC pipe shall be installed in o manner which will provide for expansion contraction as recommended by the pipe manufacturer. I. Centerload all plastic pipe prior to pressure testing. J. All threaded plastic-to-plastic connections shall be ossembled using Teflon tape or Teflon paste. K. For plastic-ta-metal connections, work the metal connections first. Use o non-hardening pipe dope on all threaded plastic-to-metal connections, except where noted otherwise. All plastic-to-metal connections shall be mode with pla,tic female adopters, L. All connections between PVC lateral lines shall be mode using Sch. 40 PVC fittings with compression adapters. All connections between dripperlines to be mode using compression fittings of manufacturer of the dripperline. Use no pipe dope, Teflon tape, primer or solvent cement on compression fittings. .3.05 CONTROLLER A. The e,act location of the controller ehall be approv"d by the Land,cape Architect or Owner's outhorized representative before installation. The electrical service shall be coordinated with this location. B. The Irrigation Contractor shall be responsible for the final electrical hook up to irrigation controller. C. The irrigotion system shall be programmed lo operalB during the pBriods of minimal use of the design area. 3.06 CONTROL WIRING A. Low voltage control wiring shall occupy the same trench and shall be Installed along the same route as the pressure supply lines whenever posslble. B. Where more than one wire is pieced in a trench, the wiring •holl be toped together in o bundle at intervals of 10 feet. Bundle shall be secured to the mainline with tape at intervals al 20 feet. C. All connections shall be of on approved type ond shall occur in a valve box. Provide on 18 inch service loop at each connection. D. An expansion loop of 12 inches shall be provided at each wire connection and/or directional change, and one of 24 inches shall be provided at each remote control valve. E. A continuous run of wire shall be used between a controller and each remote control valve. Under no circumstances shall splices be used without prior approval. 3.07 VALVES A. Automatic control valves, manual volves, gate valves, and boll valves are to be installed In the approximate locations indicated on the drawings. 8. Valve shall be Installed in shrub areas whenever possible. C. Install all valves as Indicated in the detail drawings. D. Valves to be Installed in valve boxes shall be installed one valve per box. 3.011 VALVE BOXES A. Valve boxes shall be Installed in shrub areas whenever possible. B. Each valve box shall be installed on o foundation of .3/4 inch gravel backfill, 3 cubic feet minimum. Valve boxes shall be installed with their tops 1 /2 inch above the surface of surrounding finish grade in lawn areas and 2 inches obove finish grade in ground cover areas. 3.09 BACKFL0W PREVENTERS A. Install backflow preventer unit as indicated in the detail drawings. B. Install backflow assemblies at locations approved in the field and at height required by local codes. C. Install wye strolners and pressure regulators on the backflow assembly. D. If backflow preventer Is Installed adjacent ta a building, woll, or other obstruction, Install unit so that the test cocks are facing outword awoy from the obstruction. E. Install bock/low enclosure as recommended by the manufacturer. .3. 10 SPRINKLER HEADS A. Sprinkler heads shall be installed as Indicated on the drawings. B. Spacing of heads shall not exceed maximum Indicated an the drawings. C. Riser nipples shall be of the same size as the riser opening in the sprinkler body. D. Pop-up sprinkler heads shall not be installed using side outlet openings. 3.11 MISCELLANEOUS EQUIPMENT A. Install all ossemblies specified herein according to the respective detail drawings or specifications, using best standard practices. B. Quick coupler valves shall be set approximately 12 inches from wolks, curbs, header boards, or paved areas where <lpplicable. C. 0. 3.12 Unless designed as on integral part of the irrigation head, anti-drain 11alves will be installed under. every head. The anti-drain valve will be the same diameter as the riser and be integrol to the riser assembly. Install rain sensor o• indicated on the drawings end as recommended by the manufacturer. FLUSHING THE SYSTEM A. Prior to installation of sprinkler nozzles, the valves shall be opened and a full head of water used to flush out the lines and risers. 8. Sprinkler nozzles sholl be Installed after flushing the system has been completed. 3.13 ADJUSTING THE SYSTEM A. Contractor shall adjust valves, align heads, and check coverage of eoch system prior ta coverage test. 8. If it is determined by the Landscape Architect or Owner's authorized representative that additional adjustments or nozzle changes will be required to provide proper coverage, all necessary changes or adjustment• shall be made prior to any planting. C. The entire system shall be operating properly before any planting operations commence. D. Automatic control valves are to be adjusted so that the sprlnkler heads operate ot the pressure recommended by the manufacturer. 3.14 TESTING AND OBSERVATION A. Do not allow or cause ony of the work of this section ta be covered up or enclosed until it has been observed, tested and accepted by the Landscape Architect, Owner, and governing agencies. B. The Contractor shall be solely re•ponsible far notifying the Landscape Architect, Owner, and governing agencies, a minimum of 48 hours in advance, where and when the work is ready for testing. C. When the sprinkler system is completed, the Contractor shall perform o coverage test of each system In It• entirety to determine If the water coverage for the planted areas is complete and adequate in the presence of the Landscape Architect. 0. The Contractor shall furnish all materials and perform oil work required to correct any inadequacies of coverage due to deviations from the plans, or where the system has been willfully installed as indicated on the drawings when it is obviously inadequate, without bringing this to the attention of the Landscape Architect. This test shall be accepted by the Landscape Architect and accomplished before starting any planting. E. Final inopection will not commence without record drawings as prepared by the Irrigation Contractor. 3.15 MAINTENANCE During the maintenance period the Contractor shall adjust and maintain the Irrigation system in a fully operational condition providing complete irrigation coverage to all intended plantingo. 3.16 COMPLETION CLEANING Clean-up shall be mode as each portion of the work progresses. Refuse and excess dirt shall be removed from the site, all walks and paving shall be broomed, and any damage susloined on the work of others shall be repaired to original conditions. END OF SECTION '' AS BU IL T'' REVISIONS MUST BE APPROVED BY PUBLIC HEAL Tf-1 ENGINEER. ASST PLANNING DIRECTOR AND DISTRICT ENGINEER PRIOR TO ll>JPLEMENT A TION IN FELD, RIDG!;; l_ANDSCA~E ARCHITECTS TEL 141 248-9211 FAX 141 248 1215 R.C.£. _____ _ REVIEWED BY: INSPECTOR DAT[ R.C.E. ______ _ DATE D,6.TE BY DESCRIPTION APP'O REVISIONS APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. CITY OF CARLSBAD PLANNING DEPARTMENT ISH9TS I LANDSCAPE IRRIGATION SPECIFICATIONS GRAND PACIFIC PALISADES RESORT PHASE 2 :::~~~-:__·---~&? ______ ij./z-9'£ • ASSISTANT PLANNING DIRECTOR DATE OWN BY--'"-="-- CHKD BY --"JR-'---- FIELD BY PROJECT NO, CT 96-01 C.M.W.D. #96-509 DRAWING NO. 356-7M L8.2 SECTION 02950 LANDSCAPE PLANTING PART 1 -GENERAL 1.01 WORK INCLUDED A. Soil Preporolion. B. Planting. C. Staking. D. Sodding. E. Clean up. F. Container Pot Planting. 1.02 RELATED WORK A. Section 02811 -Landscape Irrigation System. B. Section 02970 -Landscape Maintenance 1.03 QUALITY ASSURANCE A. Source Quality. 1. Submit documontollon at l•a•t 60 days prior to planting that all plant materials ore available. Materials are subject to inspection after confirmation of ordering. 2. Materials ore subject to inspection at place of growth and upon delivery, for conformity to specifications. Inspection, approval and rejection can also toke place at other times during progress of work. 3. Request, in writing, inspection of plant materials at place of growth. Identify place of growth, and quantity of plants to be inspected. Inspection may be waived ot the Owner's option. 4. As described in the planting notes for tree tagging ,the Landscape Architect may opt to either visit the tree nursery or review photographs submitted by the Contractor. In either case visit the nursery and select trees conforming to specifications prior to review by the Londscope Architect. Should trees not meet specifications at the time of review in person by the Landscape Architect, the Contractor moy be required to reimburse the Owner at the Consultant's current billing rate. 1.04 SUBMITTALS A. Prior to instollotion submit for review and approval specifications and product information on items being used on project. Submit bound with list of Items os cover sheet. 1.05 DELIVERY, STORAGE AND HANDLING A. Deliver fertilizer to site In original unopened containers bearing manufacturer's guaranteed chemical analysis, name, trade mark, and conformance to State low. B. Provide copies of receipts for all amendments specified in these speciflcotions or in the Soils Report. C. Deliver plants with legible identification labels. Lobel tree,, evergreens, bundles of containers of like shrubs and groundcover plants. Stole correct plant name and size indicated on plant list. Use durable waterproof labels with water-resistant inK which will remain legible for at least 60 days. D. Protect plant material during delivery ta prevent damage ta root boll or desiccation of leaves. E. Notify Owner 7 days in advance of delivery of plant materials ond submit itemization of plants In each delivery. F. Store plants In shade ond protect from weather. G. Maintain and protect plant material in a healthy, vigorous condition. H. Exercise care in handling, loading, unloading ond storing of plant moteriols. Replace damaged materials. 1.06 JOB CONDITIONS A. Perform actual planting only when wecther and soil conditions are euitoble in accordance with locclly cccepted proclice. B. Coordinate this work of this section with in,.toll □tion of underground irrigation sy,,tem, utilities, piping and watering heads. 1.07 SAMPLES AND TESTS A. Owner reserves the right to toke and analyze samples of materials for conformity to opecificotions. Provide samples for testing upon request. Remove rejected materials from site immediately upon rejection ot no additional cost. Testing costs will be paid for by Owner if materials prove to be in compliance with specifications. B. Prior to amending soils, contractor shall hove soil tested for agricultural suitability as described In planting notes. City inspector must approve soil test recommendations prior to delivery of soil cimendments on site. C. Provide 1 cubic foot sample of medium grind topping mulch ta Owner and City Inspector for review and approval. 1.08 GUARANTEE A. Guarantee materials against poor, Inadequate, diseased ond Inferior materials and workmanship for one year ofter 90 day maintenance agreement expiration. PART 2 -PRODUCTS 2.01 MATERIALS A. The following organic, soil amendments ond fertilizer are to be used for bid purposes only. Specific amendments and fertilizer will be selected ond specified ofter rough grading operations ore complete and Contractor has hod soil samples tested. 8. Provide standard, approved and first-grade quality materials, in prime condition when installed and accepted. Deliver commercially processed and packaged material In manufacturer's unopened containers bearing the manufacturer's guaranteed analysis. Supply a sample of oil supplied materials accompanied by analytical dot□ from on approved laboratory source illustrating compliance, or bearing the manufacturer's guaranteed analysis. C. Organic Amendment: 1. Nitrogen Stabilized: D.56 to 0.84 percent N based on dry weight for wood residual or rice hulls. 2. Particle Size: 95 to 100 percent passing 6.35 mm standard sieve; 80 to 100 percent passing 2.33 mm standard sieve. 3. Salinity. Ensure that saturation extract conductivity does not exceed 3.5 mllllmohs per centimeter ot 25 degrees C. os determined by saturation extract method. 4. Iron Content: Minimum 0.08 percent dilute acid soluble Fe on dry weight basis. 5. Ash: 0 to 6 percent dry weight. D. Soil Amendment: 1. Soil Sulfur: Agricultural grade sulfur containing minimum of 99 percent sulfur expressed as elemental. 2. Iron Sulfate: 20 percent Iron expressed as metallic iron, derived from ferric ond ferrous sulphote, 10 percent sulfur expressed os elemental. 3. Calcium Carbonate: 95 percent lime os derived from oyster shells. 4. G:,psum: Agriculturol grade product contoining 98 percent minimum colcium sulphote. E. Fertilizer: 1. Plontlng Fertlllzer: pelleted or granular form consisting of the following percents by weight and mixed by commercial fertilizer supplier: 6-nitrogen, 20-phosphorlc odd, 20-potosh. 2. Planting Tablets: Provide slow-release type with potential acidity of not more \hon 5 percent by weight containing the following percents by weight of nutrients listed: 20-nitragen, 10-phosphoric acid, 5-patash, 2.6-combined calcium, 1.6-combined sulphur, 0.35-iron elemental from ferrous sulfate. Provide in 21 gram tablets manufactured by Agrlform, or other approved. 3. Hydroseeding Fertilizer: provide ammonium phosphote which consists of the following percent by weight and mixed by a commercial fertilizer supplier: 16-nitrogen, 20-phosphoric acid, 0-potosh. 4. Pre-Sod fertilizer: Provide t:,pe consisting of the following percents by weight and mixed by a commercial fertlllzer supplier: 16-hydrogen, 20-phosphorlc ocld, 8-potash. 5. Sulphate of potash: 0-0-50. 6. Single super-phosphate: Commercial product containing 18 to 20 percent ovollable Phosphoric Penloxide, or other approved. 7. Urea formaldehyde: 38-0-0. F. Import or Amended Top Soil: Ensure silt plus cloy content of top soil does not exceed 20 percent by weight, with o minimum 95 percent passing the 2.0 mm sieve. Do not allow the sodium obsorption ratio SAR to exceed 6. The electrical conductivity (ECE) of the saturation extract cannot exceed 3.0 millimohs per centimeter at 25 degrees C. Ensure boron content Is less than 1 port per million as measured on the soturotlon extract. To ensure compliance with these requirements, submit samples of soil for analysis prior to, ond following backfilling. G. Plant Materials: 1. Provide plant materials in accordance with State Department of Agriculture's regulation for nursery inspections, rules and ratings. Provide plants with o normal habit of growth, sound, healthy, vigorous and free from Insect infestations, plant diseases, sunscalds, and other disfigurements. Ensure tree trunks ore sturdy and hove well hordened systems ond vigorous and fibrous root systems which ore not root or pot-bound. In the event of disogreement as to condition of root system, the root conditions of the furnished plants in containers will be determined by removal of eorlh from the roots of not less than twa plants, or more than 2 percent of the total number of plants of each species or variety. Where container grown plants are from several sources, roots of not less !hon two plants of eoch species or variety from each source will be inspected. In the event \hot the somple plants inspected ore found to be defective, the entire lot or lots of plants represented by the defective samples may be rejected. Plants rendered unsuitable for planting due ta this inspection will be considered samples and will be provided at no cost to the Owner. 2. Size of plants will correspond with that normally expected for species and variety of commercially ovalloble nursery stock or as specified on drawings. The minimum acceptable size of plants measured before pruning with the branches in normal position, must conform with the measurements specified in plant list. If approved by The Owner, larger sized plants may be used, but without additional cost. If larger plants ore approved for use, the boll of earth or spread of roots for each plant will be increased proportionately. 3. Plants not meeting requirements of these specifications ore considered to be defective whether In place or not. They must be immediately removed and replaced with new acceptable and approved plants of the required size, species and variety at no additional cost to the Owner. 4. Pruning: Oo not prune, trim, top or oiler the shape of trees or plants except as approved. 5. Provide plant material true to botanical and common name and variety as specified in Annotated Checklist of Woody Ornamental Plants In Colifornio, Oregon and Washington, published by University of California School of Agriculture (!oles\ edition). 6. Nursery Grown and Collected Stock: Grow under climatic conditions similar to those In locality of project; container-grown stock in vigorous, healthy condition, not root-bound or with root system hardened off. Use only liner stock plant material which is well established in removoble containers or formed homogeneous soil sections. 7. Sod: Provide Marathon. 6. Select trees which ore aesthetically desirable and ore good examples of the species. Trees with goshes, mishoppen trunks or branches, topped leaders, structural defects, badly crossed branches, or other visuol defects will not be accepted. H. Guying and Stoking Materials: 1. Wood Tree Stokes: lodge pole pine, full treated iwth Coppernaphthonote Wood Preservative in strict accordance with FS TT-W-572 Type I, Composition B,2 inch minimal normal size diameter by 10 feet long, no split stokes. 2. Ties: Provide 36 inch corded rubber tie as manufactured by Gro-Strolt Products, wire and hose tie by Nunes Turfgross, or other approved. Provide rigid tie stock No. LP, 24 inches as manufactured by VIT campony or other approved. 3. Steel Guy Anchor, provide 3/4 Inch diameter by 36 inch steel vane os manufactured by Maxwell Steel Company, or other approved. 4. Guying Hardware: Wire-pliable 9 gouge galvanized; hose 1 /2 Inch new rubber; turnbuckles -galvanized or dip painted, si,e as required: safety sleeve -1 /2 inch white pvc full length of wire. I. Tree Point: Provide Morrison Tree Seal, Cabot Tree Paint, or other approved. J. Water: Provide clean, potable water. K. t.tulch: Provide medium grind bark such oo supplied by Michael Rowls Company (714)!133-36!16, planting note "W", Sheet 5. consisting of fibrous, woody bork mixture of varied particle size such that 90 lo 100 percent passes 1 inch sieve, 80 to 100 percent posses 1 /2 inch sieve, and 20 to 60 percent passes 1 /4 inch sieve, or approved equal. L. Woad Headerboards: 1. Provide 2 inch by 4 inch pressure treated Douglas fir or redwood construction grode headerboords. Make splices with 1 Inch by 4 inch pieces no less that 12 inches long. Place 1 inch by 3 inch by 16 inc stokes at intervals of not more \hon 5 feet. Cut stokes level and set below top heoderboords. 2. On sharp turns and curves, four 1 /2 inch by 4 inch lomincted boards, or two 1 inch by 4 inch laminated boards may be permitted. 3. Nail stokes and splices with galvanized common nolls. Noll as required for solid installation. 4. Provide headerboords as shown on drawings, laid true to line and grade. protect in-place adjacent improvements, shrubbery and other properties. Place stokes on ground cover sod of headerboords. M. Sand: Provide washed silica sand. N. Root Barrier: UB24-2 by Deep Root Corp .. (714)896-0563. Install with gravel backfill option per manu focturers specifications. PART 3 -EXECUTION 3.01 INSPECTION A. Obtain certification that final grades to 1/10 foot have been established prior to commencing landscaping operations. Provide for inclusion of all amendments, settling, etc. Be responsible for shaping all planting areas os indicated on drawings or as required. B. Inspect trees, shrubs and liner stock plant material for injury, insect infestation ond trees and shrubs for improper pruning. C. Do not begin plcnting of trees until deficiencies ore corrected or plants replaced. 3.02 PREPARATION A. Soil Preparation: 1. After proper finished grades hove been verified or established, condition ond fertilize sail In occordonce with recommendations of soil testing laboratory and os approved by Owner ond City Inspector. The following is for bid purposes only. Uniformly spread and cultivate amendments thoroughly by means of mechonlcol tiller into top [6] inches of soil. Application rotes per 1,000 square feet: Nitrogen stabilized organic amendment - 16-6-8 Commercial Fertilizer - Agrlcul turol gypsum - Soil sulphur - 6 cubic yards 15 Pounds 200 pounds 15 pounds 2. At time of planting, ensure that top 2 inches of all areas to be planted ar seeded are free of stones, stumps, and other deleterious molter 1 Inch In diameter or larger, and free from wire, plaster, concrete, wood, and similar materials which would cause hindrance to planting or maintenance. B. Fino! Grades: Make minor modiflcotlons to grade os may be necessary to establish required final grade. Ensure tho\ finish grade provides proper drainage of the site and surfoce drainage is owoy from building. Final grades □re to be 1 inch below odjocent paved areas, sidewalks, valve boxes, headers, clean~outs, drains. rnot1hole~, etc .• or as shown on drawings or required by Architect. Eliminate erosion scars prior to commencing maintenance period. 3.03 JUTE MATTING A. Apply and incorporate fertili,er and amendments into the soil os specified prior to jute matting installation. B. Roll matting in the direction of the flow of water in drainage channels and smooth and secure In place os shown on plans. The material shall be applied without stretching ond lie smoothly but loosely on the soil surface. In coses where one roll of matting ends and a second roll storts, the up channel piece shall be brought over the burled end of the second roll so that there is a 12 inch overlap. Where two or more widths of matting ore applied, side by side, the overlap shall be not less than 3 inches. C. Maintain jute molting until all work on the Project has been completed and accepted. Maintenance shall consist of the repair af eroded areos and the repair or replacement and restopling of loose or undermined matting, including reseeding and bedding. D. Make check slots before the matting is rolled out. Dig o narrow trench across the channel perpendicular to the direction of the flow. Fold jute, the same length os the trench, ond press together. Location of check slots shall be maximum of 50 feet apart. E. Overlop which runs parallel to the direction of the flow in channel bottoms shall be stapled ot 2-lnch intervals. Outside edges, centers and overlaps on banks shall be stapled across the channel at 6-inch intervals. F. Spread loose topsoils over outside edges to allow for smooth entry of water. G. Top dress Jute area with a thin layer of topsoil. After the top dressing, the yarns shall still be visible. H. Install plant material through matting. L Any clods, which hold the jute off the ground shall be stamped into the soil. Force jute matting down into any depressions ond hold there with a staple. J. The matting shall completely covered all areas as shown. Overlaps must be ample ond well stapled. Loy malting smoothly, loosely, ond in continuous contact with the soil surface at all points. 3.04 PLANTING INSTALLATION 4. Provide excavated holes with vertical sides with roughened surfaces and of a size twice the diameter and 1-1/2 times the depth of the root ball for all trees and shrubs. 5. Remove bottom of plant boxes before planting. Remove sides without damage to root ball ofter positioning plant and partially backfilling. 6. Center plant in pit or trench. 7. Face plants with fullest growth into prevailing wind. 8. Set pion! plumb and hold rigidly in position until soil hos been firmed around boll or roots. 9. Backfill for container plants ta be: 6 parts by volume on-site soil 4 ports by volume organic amendment 1 pound 6-20-20 fertilizer mix/cu. yd. of mix 2 pounds Iron sulfate per cubic yard of mix Note: The above is for bid purposes only. Specific backfill recommendations ore made as o result of the soils testing described on the planting plan. 10. Raise oil plants which settle deeper than the surrounding grade. After plant hos been placed, add sufficient backfill to hale to cover approximately 1 /2 of root ball. Add water to the top and thoroughly saturate root boll and adjacent soil. 11. After water hos completely drained, place planting tablets (21 gram unless otherwise noted): 1 5 gram tablet per plug of flatted graundcover 1 tablet per 1-gollan container 2 tablets per 5-gollon container 3 tablets per 15-gallan con toiner 4 tablets per 24 inch bo• 5 tablets per 30 inch bo• 6 tablets per 36 inch box 7 tablets per 42 inch box 8 tablets per 48 inch and larger boxes Set planting tablets with each plant on top of root ball while plants ore still In their containers so the required number of tablet. con be verified. 12. Backfill remainder of hole and tamp firm. Construct an earthen basin aroond eoch plant ofter backfilling. Provide basin of depth sufficient to hold at least 2 inches of water. Construct basins with amended backfill. Remove basin in all turf areas after initial watering. 13. Limit pruning lo minimum necessary. Remove injured twigs and branches. Pruning moy not be done prior to delivery of plants. Paint cuts aver 3/4 inch in diameter with tree point. 14. Stoke trees immediately ofter planting. Install stokes plumb. 15. Do not bring iron sulfate into contact with concrete surfaces due to potential staining. Contractor is responsible for cleaning or replacing stained surfaces. E. Pion ting Groundcover: 1. Ensure that groundcover remains in the flats until transplanting. sufficient moisture so it will not fall apart when lifting plants. Flats' soil mu st con loin 2. Plant groundcovers in straight rows evenly spaced unless shown otherwise, and ot intervals required by drawings. Use triangular spacing unless otherwise noted on drawings. 3. Plant eoch rooted plant with its proportionate amount of flat soil. lmm8diately sprinkle after planting until entire area is soaked to full depth of each hole. Protect plants from damage and trampling. F. Sod Planting: 1. Remove rocks, weeds, debris from oreos to be sodded. Work up soil la a depth of 6 inches, and break up oll clods. 2. Carefully smooth oll surfaces to be sodded. Roll oreo to expose soil depressions or surface irregularities. Regrade as required. 3. Spread turf fertilizer 16-20-0 onto soil evenly at rote of one pound per 100 squore feet of lawn area. Rake in lightly. Be sure soil is level and smooth before laying sod. Avoid laying sod on bone dry soil. 4. Loy first strip of sod slobs along a straight line use o string in irregular areas. Butt joints tightly, do not overlap edges. On second strip, stagger joints much as in laying masonry. Use a sharp knife to cut sod to fit curves, edges, sprinkler heads. 5. Do not lay whole lawn before watering. When o conveniently large area has been sodded, water lightly preventing drying. Continue to lay sod, and to water until installation Is complete. 6. After laying sod, roll lightly to eliminate irregularities ond to form good contact between sod ond soil. Avaid heavy roller or e,<cessive initial watering which may cause roller marks. 7. Water thoroughly the completed lawn surfoce. Soil should be moistened at least 8 inches deep. Repeat sprinkling or regular intervals to keep sod moist at all times until rooted. After sod is established, decrease frequency ond increase amount of water per application as necessary. 8. Replace oil dead or dying sod with equal moterlol. G. Container Pot Planting: 1. If not specified, submit annual color choices to Owner for approval. 2. Place plonls and liners as required. 3. Backfill pot to within 1 inch of rim with o thoroughly mixed blend of: 4 cy washed plaster sand, 3 cy peat moss, 3 cy fiNe nitrolized fir bark, 4 lbs Calcium Carbonate lime, 4 lbs Dolomite lime, 20 lbs 6-20-20 fertilizer, 1 lb Iron sulfate. Amounts ore for 10 cy. H. Mulch Cover: Dress all graundcover, perennial and annual beds with 3" layer of mulch, except 3: 1 slopes ond turf oreos. A. Generol: 3.05 CLEAN-UP 1. Perform actual planting only during those periods when weather and sail conditions ore suitable and in accordance with locally accepted practice, as approved. 2. Distribute in plonting oreos only os many plants as con be planted and watered that same day. 3. Ensure that containers which ore opened and plants removed ore handled with core such tho! boll of earth surrounding roots is not broken and that plants ore planted ond watered immediately. Do not open containers prior to placing plants in planting areas. <I-. The irrigation system shall be operational ond approved prior to planting. B. Pre-Plant Weed Control: 1. Use o non-selective systemic contact herbicide as recommended and opplled by on approved licensed landscape pest control advisor and applicator. Leave sprayed plants intact for ot leost 15 days. 2. Clear and remove these existing weeds by mowing or grubbing off oil plant ports ot least 1 /4 inch below surface of soil over entire areas to be planted. 3. After irrigotion system is operational, opply waler for 5 to 10 doy,i as needed to weed germination. Apply contact herbicides and wait as needed before planting. as required. 4. Maintain weed free site until acceptance by Owner, achieve Repeat C. Lay-Out: Mork locations for plants and outlines of oreos to be planted before any plant pits are dug. Gain Owner approval. If underground construction or utlllty llnes ore encountered In the excavation of planting areas, other locations far planting may be selected by Owner. Accomplish layout with flagged grade stakes indicating plant names and specified container si,e on each •lake. Confirm location and depth of underground utilities and obstructions. O. Planting of Trees and Shrubs: 1. Strip and stock approved excavation for plontlng which Is encountered within areas for trenches, tree hales, plant pits and planting beds. 2. Remove from site excess soil generated from planting holes and not used for backfilling. 3. Protect areas from excessive compaction when trucking plants or other materials to planting areas. A. After all planting operations ore complete, remove all trash, excess soil, empty plant containers, and rubbish from the property. Repair scars, ruts and other marks In the ground ond leave ground in a neat ond orderly condition. B. Leave the site in o broom-clean condition, and wash down all paved areos within the project site. Leave walks in □ clean and s□fB condition. 3.05 OBSERVATION SCHEDULE A. Notify Owner in advance for the following inspections, according to the time specified: 1. Pre-Job conference -7 days. 2. Final grade review -48 hours. 3. Plant material review -4B hours. 4. Plant layout review -4B hours. 5. Soil preparation and planting operations: one tree with each type of specified stoking -48 hours. 6. Pre-maintenance -7 days. 7. Final inspection -7 days. B. If Owner authorizes o party other than the Landscape Architect to make scheduled inspections, present Landscape Architect with evidence of such inspections. C. No site visits shall commence without oil items noted in previous observation reports either completed or remedied unless such compliance hos been waived by the Owner. Failure to accomplish punchllst tasks or prepore adequately for desired inspections shell make the Contractor responsible for reimbursing the Owner at Consultants current billing rate per hour plus transportation costs. No further inspections shall be scheduled until this charge hos been paid and received by the Owner. END OF SECTION PLANTING AND INCLUDING PRECISE PLANTING AREAS. APPROVED FOR IRRIGATION ONLY, LOCATION OF '' AS BU IL T'' REVISIONS MUST BE APPROVED BY PUBLIC HEALTH ENGINEER, I SHBEET I CITY OF CARLSBAD II SHE!TS I ASST. PLANNING DIRECTOR ANO DISTRICT ENGINEER PRIOR TO '--::::::::=:::::..':==:::P:::L:::A::N::N::l:::N::G::::::D::E::P:::A;;:;:cR;;;;T::M::E:::N:::T:;::c:;=:::::..':=="=~ DATE R.C.E. R.C.E. _______ _ RI D G E REVIEWED BY: LANDSCAPE ARCHITECTS TEL 949 241-9211 rAX 949 241 9215 INSPECTOR DATE IMPLEMENTATION IN FIELD. ~ DATE BY DESCRIPTION APP'D REVISIONS LANDSCAPE PLANTING SPECIFICATIONS GRAND PACIFIC PALISADES RESORT PHASE 2 APPROVE~/'✓--;; ____ _ ,£0' ir--12-y'f ' ASSISTANT NING DIRECTOR OWN BY--==,__ __ CHKD BY _"'JR-'--- rlELD BY PROJECT NO. CT 96-01 C.M.W.D. #96-509 DATE DRAWING NO. 356-7M L8.3 SECTION 02955 PALM TREE PLANTING AND MAINTENANCE PART 1 GENERAL 1.01 WORK INCLUDED A. Palm trees. B. Pruning. C. Removals, backfill. D. Maintenance. 1.02 RELATED WORK A. Section D21'l11 -Landscape Irrigation. B. Section 02970 -Landscape Planting C. Section 02950 -Landscape Planting 1.03 QUALITY ASSURANCE A. Source Quality Control; 1. Submit documentation to Landscape Architect at least 80 days prior to planting thot oil plant moterials ore available. Contractor is responsible for ell palm tree materials listed an plant list. Substitutions due to unavailability must be requested In writing prior to confirmation of ·ordering. All materials are subject to inspection by Landscape Architect at any time ofter confirmation of ordering. 2. Plants are subject to observation and approval of Landscape Architect at place of growth. 1.D4 GUARANTEE A. Newly planted palm trees shall be guaranteed against any and all poor, inadequate, or Inferior plant material•. and workmanship for two years following planting and acceptance by Owner. B. During the guarantee period, any material found dead or not in o satisfactory growth condition •hall be removed from the site. C. These trees and disturbed Improvements shall be replaced at no added expense to th• Owner, with the some variety and size as originally designated. Palms and all disturbed areas shall be guaranteed for two years from time of planting ond re-planting to the satisfaction of the Owner. 1.D5 OBSERVATIONS AND PER~ITS A. Observation 1. Notify Owner's representative minimum of 72 hours in advance of observations to schedule required Inspections .. 2. All palms ore to be Inspected by o palm expert for disease prior to their preparation for removal from growing site. Contact, schedule and pay for this in•pection at no extra cost to the Owner. The inspection will toke place from ground level with field glosses. If disease is suspected provide a man lift for closer inspection ot no extra cost to the Owner. , 3. The palm expert shall be Dr. Henry Donselmon (619 / 679-7384) unless otherwise approved in advance by Owner's authorized representative. 4. All palms will be observed by the Landscape Architect for. height, girth, and overall form in meeting design intent. Said observation ond approval does not con•titute a review of the palm's health, vigor, and required health-free state, for which the Contractor is solely responsible. 5. The landscape Architect may opt ta either visit the tree nursery or review photographs submitted by the Contractor. In either case visit the nursery and select trees conforming to specification prior to review by the Landscape Architect. Should tree not meet specification at the time of review in pernon by the Londocope Architect, the Contractor may be require to reimburse the Owner at the Consultant's current billing rote. 6. Observotions ore as follows; Observation Ob servo lion of trees ot source Observation of planting locations on site prior to digging pits Observation of palm on site prior to planting for verification of conformance to plans and specifications Observation of condition of equipment and typical planting operations (1st planted palm) Pre-maintenance ob•ervation Observation at end of maintenance period B. Permits Palm Tree Expert X Contoc\; 1. Provide all necessary permits at no additional co•t• to Owner. Owner's Representative X X X X X 1.06 PROTECTION AND RESTORATION OF EXISTING IMPROVEMENTS 1.07 A. Exercise extreme core in excavating planting or working near 11xlsting utilities or irrigation systems. B. Be responsible for damages to utilities which ore caused by work operations or neglect. C. Check utility drawings and os~bullt plans for utility and irrigation locations. D. Reploce all plant materials disturbed by exccvotion or palm tree will be replaced will not require replanting. planting of groundcover or turf with existing. JOB CONDITIONS planting. Plont-pit oreo where After tree is in place, blend A. Perform octuol planting only when weather and soil conditions ore auitobl" in accordance with locally accepted practice. B. Do not plant palm between October 31 and April 1. unle•• the approved palm expert provides written recommendation to do so, and unless this recommendation is approved in advance by the Owner. 1.0l'l SAMPLES AND TESTS A. Landscape Architect reserves the right to toke and analyze samples of materials for conformity to specification• at any reasonable time. B. Provide samples upon request by Landscape Architect. C. Rejected materials shall be immediately removed from the site at Controctor'll expense. D. Cost of testing of materlols not meeting specifications shall be paid by Contractor. PART 2 PRODUCTS 2.01 PALM TREE DESIGN STANDARDS A. All palm trees are to be of unlfonm quality end oppeoronce, matching representative sample approved by Landscape Architect. B. Trunk condition shall be free of any scarring or blemishes. Contractor to clean trunk and form pineapple per specifications. C. Brawn trunk height shall be per Drawings. D. Trunk diameter per heights stipulated in the drawings shall not vary more than 25 percent. 2.02 PALM BACKFILL SOIL A. Backfill mix shall consist of waslied concrete sand, and silt plu• cloy content af this •all shall not exceed 20% by weight with a minimum 95% passing the 2.0 millimeter sieve. The sodium absorption ratio (SAR) shall not exceed 6 and the electrical conductivity (ECE) of the saturation extract of this soil shall not esceed 3.0 millimhos per centimeter at 25 centigrade. The boron content of this sond shall be no greater than 1 pm as measured on the saturation extract. In order to insure conformance, •ubmit samples of the import sand to the soils laboratory for onolysls prior to backfilling and submit report to Owner's representative. 2.03 FERTILIZER A. After 14 days, then monthly, spray the frond (foliar drench) with the following mi•ture. No compound should esceed its recommended rote. The following rotes ore for a 100 gallon tonk mix. 1. Kocide• 101 w.p. (3/4 lb.) or Monzote•• -1 qt. / 100 gallons. 2. W.R. Grace's Minor-Gro (1 /2 cup) 3. Hydrated urea (5 cups or 2-1/2 lbs.) 4, Spreader Sticker -8 oz. "Basic H" 5. 1 lb. Benlote / 10D gallons of water 6. Option: Add o general insecticide to pravent insect larva infestation. (We hove dropped the insecticide in our mix due to the increased environmental and health risks.) All rotes ore recommendations only. Do not exceed label directions. Be sure to fallow oil label instructions. B. Fertilizer will not be used ot time of planting. After four weeks, use o light application of "Wood Ace Palm Special" available from W.D. Young (619 / 347-7906) approximately 6 lb. nitrogen per tree llghtly cultivated into the soil. PART 3 EXECUTION 3.01 PALM TREE SOURCE AND PREPARATION FOR PLANTING A. Obtain source of palms for inspection end approval by Palm Tree Expert and Lond•cope Architect. B. Submit documentation and permits (if required) that the source of palm trees i• approved. Obtain palms from on approved source and replace or repair damage from palm tree removal. C. Palms collected for planting shall be grown under climatic conditions similar ta those in locality of project. D. Palms shall be Inspected by the Palm Tree Expert to Include health. defrondlng, tying and palm removal. Any palms rendered unsultoble for planting because of this inspection shall not be used. Reinspection of suitable polms will be at the Contractor's expense. E. All palms must be togged, inspected, ond approved by the Palm Tree Expert and by Landscope Architect for planting prior to shipment and installation. F. Defronding ond Tying; 1. In preparing palm trees for relocation, all dead fronds shall be removed and the entire trunk diamond cut clean to the height of green fronds. Core shall be token to prevent Injury to the trunk of the tree. Green fronds below a horizontal position shall be neatly cut off leaving a 4 inch stub. 2. All remaining fronds above horizontal shall be lifted up and tied together around the crown in on upright position. Due caution shall be token not to bind or injure the crown, A lightweight rope or cord not less then 1/4 inch in diameter shall be used in tying up the fronds; wire will not be permitted. After tying, the tips of the fronds shall be hedged off above the crown approximately 1 /3 to 1 /2 of the frond length. De/randing and tying work shall be completed prior to digging the raotball. Submit documentation that palms have been reviewed by the palm tree expert and that they ore disease free. G. Digging the Rootboll; 1. When digging out the rootball, no excavation shall be done closer than 24 Inches to the trunk ot ground level ond the excavation shall extend below the major root system to o minimum depth of 6 feet. The bottom of the rootboll shall be cut off square and perpendicular to the trunk below the major root system. Under no conditions shall the Contractor cut down the size of the rootboll In width or depth. 2. The Contractor shall not freefall, drag, roll, or abuse the tree or put o strain on the crown at any time. A protective device shall be used around the trunk of the tree while lifting and relocating so os not to scar or skin the trunk In any way. This device shall consist of either o rubber or leather sling made out of timbers sufficiently sized to withstand coble/choker pres•ure. At no time will trees be bolled out and laid on the ground with rootboll left exposed to direct sunlight and olr. The rootball shall be kept moist and shaded ot all times. 3. Palms shall not be stockpiled far replanting. 3.02 PLANTING OF PALMS A. B. C. D. E. F. G. Excavation for planting shall include the stripping ond stocking of all acceptable topsoil encountered within the areas ta be excavated for the tree hole•. Excess soil generated from the planting hole• and not u•ed □• backfill or In establishing the final grades shall be removed from tlie site. Protect all areas from excessive compaction when trucking pion ts or other material to the planting site. Center palm in pit or trench; align with other palms. Set polm plumb and hold rigidly in position until sand hos been watered in around roots, The sand needs to be washed into voids around root. to achieve a good interface. All excavated holes •hall hove vertlcol sides with roughened surfaces and sholl be of o size that is twice the diameter and 24 inch minimum to 4 foot maximum deeper In the ground than the palms originally stood. Root-growth stimulant shall be applied when the bockfllllng Is between 1 /2 to 2/3 up the rootboll. Application rote shall be one ounce of "Basic H" ond 2 tablespoons of "Stem" in o 5 gallon bucket of water. Stlmulont shall be poured full strength equally distributed around the rootboll, and watered in thoroughly. 3.03 CLEANUP A. Following planting work, all remaining excavation ehall be backfilled and compacted In accordance with the requirements of \he Londscope Architect. Burying of debris in holes will not be permitted. All exces• soil and debris from the relocation work shall be disposed of off the site by the Contractor. This site shall be left neat ond clean to the sotisfoctlon of the Owner. 3.04 MAINTENANCE A. 1. 2. Be responsible for maintenance and guarantee of all ln,tolled new palms and existing palms to the satisfaction of the .Owner. Maintenance will include, spraying to control or prevent disease and weekly water management ta include sail probing and maintenance of sump clean-out pipe and palm tree pruning. Pruning shall be done with reciprocal sows (chain sows will not be allowed). 3. Sow blades will be sterilized between each tree with 50% household bleach and 50% woter for five minutes, 4. Pruning will be done to maintain· o neat appearance as approved by the Landscape Architect. 5. Proposed pruning schedule Is to be submitted to the Landscape Architect for approval. B. The spring ofter planting, loosen but do not fully remove rope around fronds. Fully remove rope at end of summer, 60 days after planting, END OF SECTION SECTION 02970 LANDSCAPE MAINTENANCE PART 1 GENERAL 1.01 SECTION INCLUDES A. [90] day maintenance. B. Weeding. C. Fertilization. 1.02 RELATED WORK SPECIFIED IN OTHER SECTIONS A. [Section 02811 -Landscape Irrigation.] B. [Section 02955 -Palm Tree Planting and Maintenance.] C. [Section D295D -Landscape Planting.] D. [Section 02514 -Portland Cement Concrete Paving.] 1.03 QUALITY ASSURANCE A. Provide services by on experienced landscaping maintenance company. 1.04 MAINTENANCE PERIOD A. Continuously maintain all site areas Involved in this contract during the progress of work and during the maintenance period until final acceptance of the work by Owner. Improper maintenance or possible poor condition of the project ot the termination of the scheduled maintenance period may cause postponement of the final completion dote of the Contract al no additional cost lo Owner. Continue maintenance until acceptable to the Owner. B. Provide sufficient numbers of workers and adequate equipment to perform work during maintenance period. C. Maintenance period does not start until all elements of construction, planting, end irrigation for the complete project ore in accordance with the contract documents for this project. D. Request on inspection to begin maintenance period ofter oil planting and related work hos been completed in occordonce with contract documents. Maintenance period commences as described in written notification by the Owner. E. Prior ta commencement of maintenance period. ensure that all ground covers and lawn areas hove been planted and that all lawn areas show on even, healthy stand of gro•s seedlings or sod, gross having been mown twice. F. Any day or days that there Is failure to properly maintain plantings, replace suitable plants, perform weed control or maintain hardscape areas will not be credited as port of the [9D] days maintenance. The project will not be segmented into maintenance phases. G. Keep paved areas free of silt, dirt, leaves and other planting area debris. Maintain these areas at least broom clean through the duration of the maintenance period, cleaning no less often thon once per week. 1.05 GUARANTEE ANO REPLACEMENT A. Guarantee; Guarantee plant material against any and all poor, Inadequate or Inferior material• and workmanship for one year. Replace plonto found ta be dead or in poor condition· due to faulty materials or workmanship, at no extra cost to Owner. 8. Replacement; Replace materials found to be dead, missing or In poor condition during the maintenance period immediately, The Owner Is the sale judge of the acceptability of condition. Make replacements of materials within 15 days ofter condition develops or written notification from Owner hos been sent, Owner hos the right to make emergency repairs without releasing Contractor'• guarantee and warranty to Owner. 1.06 INSPECTIONS A. Request normal progress Inspection at least 72 hours in advance of on on tlclpoted inspection. Inspections ore as follows: 1. Immediately prior to commencement of this maintenance work. 2. Completion of first (90] day maintenance period. 3. Final acceptance. 1.07 PROJECT FINAL ACCEPTANCE A. Prior to date of final Inspection, acquire approved reproducible prints and finally record from the job record set, all changes mode during construction and deliver them to Owner. B. Deliver guarantee• to Owner. PART 2 PRODUCTS 2.01 MATERIALS A. Ensure that all materials conform to other sections of these specifications for planting and irrigation, ond as ccceptable to Owner. B. Provide monthly r,1card of all herbicides, insecticides and disease control chemicals used on site. PART 3 EXECUTION 3.01 MAINTENANCE A. B. Weed and cultivate all oreos at Intervals of not more thon [10] days. Perform watering, mawing, rolling, edging. trimming, fertlllzotlon. spraying, pest control, and cleaning as may be required. C. Street gutters and curbs ore to be Included. ' D. Maintain adequate protection for people and property, and be financially responsible E. for damages and injuries. Notify Owner immediately should damage occur as o result of maintenance operations and provide repair or remuneration as required by Owner. Between the 15th and 20th calendar day of the maintenance period, reseed or resod all spots or areos within the lawn where normal turf growth is not evident. 3.02 TREE AND SHRUB CARE A. Woterlng: Maintain o large enough water basin around plants so that enough water con be applied to establish moisture through the major root zone. When hand watering, u•e o water wand to break force of water. B. Pruning: C. D. E. F. G. 1. Prior to ony pruning obtain written approval from the Owner to proceed. 2. Trees: o. Propose tree pruning to the Owner should there be health or structural reasons for doing so, including the need to eliminate diseased or damaged growth, eliminate structurally unsound growth, reduce potential far wind toppling or wind damage.or maintain growth within limited spoce. b. If requested by the Owner provide pruning for aesthetic enhancement according to "Pruning" by Sunset Books. c. Major pruning ol deciduous trees sholl be during their dormant season. 3, Shrubs; o. The objectives of shrub pruning ore the some as for trees. Do not clip shrubs into bolled or boxed farms unless such is required by the design. b. Make pruning cuts to lateral branches or buds or flu•h with trunk. Stubbing will not be permitted. Stoking and guying; Ensure tho\ stokes and guys remain in place through acceptance and monitor to prevent girdling of trunks or bronche.s and to prev11nt rubbing that causes bark wounds. All nursery stokes shall be removed. Weed control; Keep all areas free of weeds. Use recommended legally approved herbicides. Avoid frequent soil cultlvctlon that destroys shallow roots. Use mulches per specifications to help prevent weed seed germination. Insect and disease control; Maintain o reosonoble control with approved material•. Fertilize as specified by the agronomic soils testing recommendations and as follows for bid purposes; 1. Commencement of maintenance period -[6] pounds per 1,DOO square feet with tap dress fertilizer. 2. 3. 4. At end of first [30] days of maintenance period -[6] pounds per 1,000 square feet with top dress fertilizer. At end of maintenance period ond ct [3D] day intervals should maintenance period be extended for any reason -[6] pounds per 1,000 square feet with L fertilizer] mix. Avoid applying fertilizer to the root boll and base of main •tern; rather, spread evenly under plant to drip line. Rotes will vary from about a cup of nitrate fertilizer (depending upon nitrogen percentoge) around o newly installed small plant ta about 1 /2 pound of ocluol nitrogen per inch of truck diameter measured four feet from the ground for mature trees. Replacement of plants: Replace dead, dying and missing plants with plants of o size, condition and variety acceptable to Owner at no oddltlonol cost to the Owner. 3.03 GROUND COVER CARE A. Weed control: Control· weeds, preferably with pre-emergent herbicides, but also by hand or with selective systemic herbicide•. Hoe weeds as little as possible oince this may result In plant damage. B. Watering: Water enough that moisture penetrates throughout root zone and only as frequently as is necessary to maintain healthy growth. C. Trash; Remove as it accumulates, but no less often than weekly. D. Edging and trimming: Edge ground cover to keep in bounds. E. Replace dead and missing plants at no additional cost tq the Owner. 3.04 LAWN AND TURF CARE A. Turf must be well-established prior to final acceptance. B. Watering: Water lawns ot such frequency as weather conditions required to replenish soil moisture below root zone. C. Weed control: If needed, control brood leaf weeds with selective herbicides. D. Mowing: 1. Perform mowing at such times of the day or week os may be requested by the Owner so as not to impede the Owner's operations. Mowing time• may be at times other than normal working hours or days. Perform work at Owner's convenience ot no additional cost to the Owner. 2. Clean up gross clippings during and ofter mowing, and remove legolly from site. Use of blowing-type equipment in lieu of sweeping or vccuumlng Is not acceptable. E. Renovating: 1. If required, remove thatch by verticutting,preferobly in the Foll of the yeor, but otherwise in the Spring. At this time, fertilize with nitrate ond over-seed if needed. Over-seeding must precede pre-emergent herbicides by at least 4 to 6 weeks. Normally, this means that lawns which hove been invaded by crabgrass would be renovated and over-seeded in the Foll and treated for crabgrass control I the following late Winter. 2. Cleon up gross clippings during cmd ofter mowing, and remove legally from site, Use of blowing-type equipment in lieu of sweeping or vacuuming is not acceptable. 3.05 IRRIGATION SYSTEM A. Inspection: Check all systems for proper operation. Lateral lines must be flushed out ofter removing the last sprinkler heed or two ot each end of the lateral. Adjust heads as necessary for unimpeded coverage ond no overspray. 8. Controllers; Set and program automatic controllers for seasonal water C. requirements. Give Owner a key to controllers and instruction on how to turn off system In case of emergency as specified In other sections of these specifications.· Repair all damages to Irrigation system at no additional cost to the Owner. Make all repairs within one watering period. END OF SECTION APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. '' AS BU IL T'' REVISIONS MUST BE APPROVED BY PUBLIC I-EAL T~ ENGNEE:R, ASST. PLANNING DIRECTOR AND DISTRICT ENGINEER PRIOR TO llv1PLEMENT A TION IN FIELD. I SH9EET I CITY OF CARLSBAD I SHE9[TS I PLANNING DEPARTMENT LANDSCAPE MAINTENANCED SPECIFICATION AND PALM TREE SPECIFICATION RI D G E LANDSCAPE ARCHITECTS TEL 949 249-1211 FAX 149 249 121 ~ R.C.C. -----~ REVIEWED BY, INSPECTOR DATE R.C.C. ______ _ DATE BY DATE DESCRIPTION REVISIONS GRAND PACIFIC PALISADES RESORT PHASE 2 OWN BY---'"-="'--CHKD BY __ ~ __ _ FIELD BY PROJECT NO, CT 96-01 C.M.W.D. #96-509 DRAWING NO, 356-7M L8.4