HomeMy WebLinkAboutDWG 483-2A; CT 13-06; LA COSTA VILLAS; 01-09GRADING NOTES: {IN ADDITION TO THE REQUIREMENTS OF CHAPTER 15.16 OF THE CARLSBAD MUNICIPAL CODE) 1. THIS PLNJ SUPERSEDES ALL OTHER PLANS PREVIOUSLY APPROVED BY THE CITY OF CARLSBAD REGARDING GRADING SHOWN ON THIS SET OF PLANS. 2. APPROVAL OF THIS PLAN DOES NOT LESSEN OR WAVE ANY PORTION OF THE CARLSBAD MUNICIPAL CODE, RESOLUTION OF CONDITIONAL APPROVAL, CITY STANDARDS OR OTHER ADDITIONAL DOCUMENTS LISTED HEREON AS THEY MAY REVISE THESE PLANS WHEN NON-CONFORMANCE IS DISCOVERED. 3. CITY APPROVAL OF THESE PLANS DOES NOT RELIEVE THE DEVELOPER OR ENGINEER-OF -WORK FROM RESPONSIBILITY FOR THE CORRECTION OF ERRORS AND OMISSIONS DISCOVERED DURING CONSTRUCTION. ALL PLAN REVISIONS SHALL BE PROMPTLY SUBMITTED TO THE CITY ENGINEER FOR APPROVAL. 4, A RIGHT-OF-WAY PERMIT FROM THE CITY ENGINEER WILL BE REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT-OF-WAY PRIOR TO PERMIT ISSUANCE, A CERTIFICATE OF INSURANCE AS WELL AS ADDITIONAL INSURED ENDORSEMENT MUST BE FILED NAMING THE CITY OF CARLSBAD AS ADDITIONAL INSURED ON THE PERMITTEE'S POLICY IN THE MINIMUM AMOUNT OF $1,000,000.00 FOR EACH OCCURRANCE OF LIAB ILITY. THE INSURANCE COMPANY WRITING THE POLICY MUST HAVE A RATING OF "A-" OR BETTER AND A SIZE CATAGORY OF CLASS VII OR BETTER AS ESTABLISHED BY "BESTS" KEY RATING GUIDE, 5. UNLESS EXEMPTED BY SECTION 301.(b)5 OF THE UNIFORM BUILDING CODE, RETAINING WALLS OUTSIDE THE PUBLIC RIGHT-OF-WAY REQUIRE SEPARATE PERMITS FROM THE BUILDING DEPARTMENT. 6. NO WORK SHALL BE COMMENED UNTIL ALL PERMITS HAVE BEEN OBTAINED FROM THE CITY AND OTHER APPOPRIATE AGENIES. 7. APPROVAL OF THESE PLANS BY THE CITY ENGINEER DOES NOT AUTHORIZE ANY WORK OR GADING TO BE PERFORMED UNTIL THE PROPERTY OWNER'S PERMISSION HAS BEEN OBTAINED AND A VALID GRADING PERMIT HAS BEEN ISSUED. 8. NO REVISIONS SHALL BE MADE TO THESE PLANS WITHOUT WRITTEN APPROVAL OF THE CITY ENGINEER, NOTED WITHIN THE REVISION BLOCK, ON THE APPOPRIATE SHEET OF THE PLANS AND THE TITLE SHEET. 9. ORIGINAL DRAWINGS SHALL BECOME THE PROPERTY OF THE CITY UPON BEING SIGNED BY THE CITY ENGINEER. 10. THE ORIGINAL D.RAWINGS SHALL BE REVISED TO REFLECT AS-BUILT CONDITIONS BY THE ENGINEER-OF-WORK PRIOR TO FINAL ACCEPTANCE OF THE WORK BY THE CITY. 11. ACCESS FOR FIRE AND OTHER EMERGENCY VEHICLES SHALL BE MAINTAINED TO THE PROJECT SITE AT ALL TIMES DURING CONSTRUCTION. 12. WHERE TRENCHES ARE WITHIN CITY EASEMENTS, A SOILS REPORT COMPRISED OF: {A) SUMMARY SHEET, (BJ LABORATORY WORK SHEET AND (CJ COMPACTION CURVES, SHALL BE SUBMITTED BY A PROFESSIONAL ENGINEER Of THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD Of APPLIED SOILS MECHANICS. THE SOILS REPORT WILL BE SUBMITTED TO THE CITY ENGINEERING INSPECTOR WITHIN TWO WORKING DAYS OF THE COMPLETION OF FIELD TEST. 13. A SOILS COMAPCTION REPORT AND COMPLIANCE VERIFICATION REGARDING ADHERENCE TO RECOMMENDATIONS OUTLINED IN THE SOILS REPORT IS REQUIRED PRIOR TO ISSUANCE OF A BUILDING PERMIT. ALL CONTROLLED GRADING SHALL BE DONE UNDER THE DIRECTION Of A PROFESSIONAL ENGINEER OF THE STATE OF CALIFORNIA PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOILS MECHANICS. ALL FILL OR FUTURE fill AREAS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CITY OF CARLSBAD STANDARD SPECIFICATIONS AND THE "EARTH WORK SPECIFICATIONS" ATTAHCED TO THE PRELIMINARY SOILS INVESTIGATION. DAILY FIELD COMPACTION REPORTS WILL BE SUBMITTED TO THE PROJECT INSPECTOR. 14. A PRE-CONSTRUCTION MEETING SHALL BE HELD AT THE SITE PRIOR TO THE BEGINNING OF WORK AND SHALL BE ATTENDED BY ALL REPRESENTATIVES RESPONSIBLE FOR CONSTRUCTION, INSPECTION, SUPERVISION, TESTING AND ALL OTHER ASPECTS OF THE WORK. THE CONTRACTOR SHALL REQUEST A PRE-CONSTRUCTION MEETING BY CALLING THE INSPECTION LINE AT (760) 438-3891 AT LEAST FIVE (5) WORKING DAYS PRIOR TO STARTING OF CONSTRUSTION. THE CONTRACTOR WILL THEN BE CONTACTED BY THE PROJECT INSPECTOR TO COORDINATE A DATE AND TIME FOR THE PRE-CONSTRUCTION MEETING. APPROVED DRAWINGS MUST BE AVAILABLE PRIOR TO SCHEDULING. GRADING PERMIT WILL BE PROVIDED BY THE PROJECT INSPECTOR AT THE MEETING. 15. ALL INSPECTION REQUEST OTHER THAN FOR PRE-CONSTRUCTION MEETING WILL BE MADE BY CALLING THE ENGINEERING 24-HOUR INSPECTION REQUEST LINE AT (760) 438-3891. INS PECTION REQUEST MUST BE RECEIVED PRIOR TO 2:00 PM ON THE DAY BEFORE THE INSPECTION IS NEEDED. INSPECTIONS WILL BE MADE THE NEXT WORKDAY UNLESS YOU REQUEST OTHERWISE. REQUEST MADE AFTER 2:00 PM WILL BE SCHEDULED FOR TWO (2) FULL WORK DAYS LATER. 16. THE OWNER AND/OR APPLICANT THROUGH THE DEVELOPER AND/OR CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING AND SHALL BE SOLELY RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL SAFETY AND HEALTH STANDARDS, LAWS AND REGULATIONS. 17. THE CONTRACYOR SHALL CONFORM TO LABOR CODE SECTION 6705 BY SUBMIHING A DETAILED PLAN TO THE CITY ENGINEER AND/OR CONCERNED AGENCY SHOWING THE DESIGN OF SHORING, BRACING SLOPING OR OTHER PROVISIONS TO BE MADE FOR WORKER PROTECTION FROM THE HAZARD OF CAVING GROUND DURING THE EXCAVATION OF SUCH TRENCH OR TRENCHES OR DURING PIPE INSTALLATION THEREIN. THIS PLAN MUST BE PREPARED FOR ALL TRENCHES FIVE FEET (5') OR MORE IN DEPTH AND APPROVED BY THE CITY ENGINEER AND/OR CONCERNED AGENCY PRIOR TO EXCAVATION. IF THE PLAN VERIES FROM THE SHORING SYSTEM STANDARDS ESTABLISHED BY THE CONSTRUCTION SAFETY ORDERS, TITLE 8 CALIFORNIA ADMINISTRATIVE CODE. THE PLAN SHALL BE PREPARED BY A REGISTERED ENGINEER AT THE CONTRACTORS EXPENSE. A COPY OF THE OSHA EXCAVATION PERMIT MUST BE SUBMITTED TO THE INSPECTOR PRIOR TO EXCAVATION. 18. NO BLASTING SHALL BE PERFORMED UNTIL A VALID BLASTING PERMIT HAS BEEN OBTAINED FROM THE CITY OF CARLSBAD. SUBMIT APPLICATION FOR BLASTING PERMIT WELL IN ADVANCE OF THE SCHEDULING OF BLASTING OPERATIONS. I 9. IF ANY ARCHAEOLOGICAL RESORCES ARE DISCOVERED WITHIN ANY WORK AREA DURING CONSTRUCTION, OPERATIONS WILL CEASE IMMEDIATELY, AND THE PERMITTEE WILL NOTIFY THE CITY ENGINEER. OPERATIONS WILL NOT RESTART UNTIL THE PERMITTEE HAS RECEIVED WRITTEN AUTHORITY FROM THE CITY ENGINEER TO DO SO. 20. ALL OPERATIONS CONDUCTED ON THE SITE OR ADJACENT THERETO, INCLUDING WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR ORPERATION OF TRUCKS, EARTHMOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATED GRADING EQUIPMENT SHALL BE LIMITED TO THE PERIOD BETWEEN 7:00 AM AND 6:00 PM EACH DAY, MONDAY THRU FRIDAY AND NO EARTH MOVING OR GRADING OPERATIONS SHALL BE CONDUCTED ON WEEKENDS OR HOLIDAYS. (A LIST OF CITY HOLIDAYS IS AVAILABLE ATTHE ENGINEERING DEPARTMENT COUNTER) 21. ALL OFF-SITE HAUL ROUTES SHALL BE SUBMITTED BY THE CONTRACTOR TO THE CITY ENGINEER FOR APPROVAL TWO (2) FULL WORKING DAYS PRIOR TO BEGINNING OF WORK. 22. IMPORT MATERIAL SHALL BE OBTINED FROM, AND WASTE MATERIAL SHALL BE DEPOSITED AT, A SITE APPROVED BY THE CITY ENGINEER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DEBRIS OR DAMAGE OCCURRING ALONG THE HAUL ROUTES OR ADJACENT STREETS AS A RESULT OF THE GRADING OPERATION. 23, BRUSH SHALL BEREMOVED ONLY WITHIN THE AREA TO BE GRADED. NO TREES ARE TO BE REMOVED UNLESS SPECIFICALLY NOTED ON THE PLAN. 24. ALL AREAS SHALL BE GRADED TO DRAIN. GRADING RESULTING IN THE PONDING OF WATER IS NOT PERMITTED. ALL EARTHEN SWALES AND DITCHES SHALL HAVE A MINIMUM ONE PERCENT SLOPE. 25. THE PLANS ARE SUBJECT TO A SIGNED AND APPROVED SET OF EROSION CONTROL PLANS. EROSION CONTROL PLANS SHALL BE AS SHOWN AND APPROVED BY THE CITY ENGINEER OR AS DIRECTED BY THE PROJECT INSPECTOR. 26. ALL SLOPES SHALL BE TRIMMED TO A FINISH GRADE TO PRODUCE A UNIFORM SURFACE AND CROSS SECTION. THE SITE SHALL BE LEFT IN A NEAT AND ORDERLY CONDITION. ALL STONES, ROOTS AND OTHER DEBRIS SHALL BE REMOVED AND DISPOSED OF AT A SITE APPROVED BY THE CITY ENGINEER. ----.--·. ·---~--- GRADING NOTES (CONT.): 27. ALL SLOPES SHALL BE IRRIGATED, STABLIZED, PLANTED AND/OR HYDROSEEDED WITHIN TEN (10) DAYS OF THE TIME WHEN EACH SLOPE IS BROUGHT TO GRADE AS SHOWN ON THE APPROVED GRADING PANS. 28. LANDSCAPING SHALL BE ACCOMPLISHED ON ALL SLOPES AND PADS AS REQUIRED BY THE CITY LANDSCAPING MANUAL, THE LAN DSCAP ING PLANS FOR THIS PROJECT, DRAWING No, 483-2L, AND/OR AS DIRECTED BY THE CITY ENGINEER OR PLANNING DIRECTOR. GRADING PLANS FOR 29. THE OWNER/APPLICANT SHALL INSURE THAT ALL CONTRACTORS SHALL COORDINATE THE WORK OF THESE GRADING PLANS WITH THAT SHOWN ON BOIH THE LANDSCAPE AND IRRIGATION PLANS AND THE IMPROVEMENT PLANS AS REQUIRED FOR THIS WORK IN ACCORDENCE WITH THE LANDSCAPE MANUAL TIME REQUIREMENTS. 30. WHERE AN EXISTING PIPE LINE IS TO BE ABANDONED AS A RESULT OF THE GRADING OPERATION IT SHALL BE REMOVED WITHIN TWENTY FEET OF BUILDING OR STREET AREAS AND REPLACED WITH PROPERLY COMPACTED SOILS. IN OTHER AREAS THE PIPE WILL BE PLUGGED WITH CONCRETE OR REMOVED AS APPROVED BY THE CITY ENGINEER. LA COSTA VILLAS 31. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING FACILITIES {ABOVE GROUND AND UNDER GROUND) WITHIN THE PROJECT SITE SUFFICIENTLY AHEAD OF THE GRADING TO PERMIT THE REVISION OF THE GRADING PLANS IF IT IS FOUND THAT THE ACTUAL LOCATIONS ARE IN CONFLICT WITH THE PROPOSED WORK. 32. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY COMPANIES (SEE BELOW) AT LEAST TWO (2) FULL WORKING DAYS PRIOR TO STARTING GRADING NEAR THEIR FACILITIES AND SHALL COORDINATE THE WORK WITH THE COMPANY REPRESENTATIVE. . .. UNDERGROUND ALERT SERVICE (800) 422-4133 ... SDG&E (800) 660-7343 ... PACIFIC BELL (800) 892-0123 ... TIME WARNER CABLE (7 60) 438-77 41 ... COX COMMUNICATION (760) 806-9809 ... CITY OF CARLSBAD (STREET & STORM DRAIN) (7 60) 434-2980 ... 'CITY OF CARLSBAD (SEWER, WATER & RECLAIMED WATER) (7 60) 438-2722 . .. 'SAN DIEGU ITO WATER DISTRICT (760) 633-2650 ... 'LEUCADIA WASTEWATER DISTRICT (760) 753-0155 ... 'VALLECITOS WATER DISTRICT (7 60) 7 44-0460 ... 'OLIVENHAIN WATER DISTRICT (760) 753-6466 ... 'BUENA SANITATION DISTRICT (7 60) 726-1340 'AS APPROPRIATE 33. PERMIT COMPLIANCE REQUIREMENTS: A) FOR CONTROLLED GRADING -THE APPLICANT HIRES A CIVIL ENGINEER, SOILS ENGINEER AND/OR GEOLOGIST TO GIVE TECHNICAL ADVISE, OBSERVE AND CONTROL THE WORK IN PROGRESS {15.16.120 A,8} CARLSBAD MUNICIPAL CODE BJ PRIOR TO FINAL APPROVAL OF THE GRADING PERMIT-THE FOLLOWING REPORTS MUST BE SUBMITTED TO THE CITY ENGINEER VIA THE PROJECT INSPECTOR (15.16.120 A, IO} CARLSBAD MUNICIPAL CODE. I) FINAL REPORT BY SUPERVISING GRADING ENGINEER STATING ALL GRADING IS COMPLETE. ALL EROSION CONTROL, SLOPE PLANTING AND IRRIGATION ARE INSTALLED IN CONFORMANCE WITH THE CITY CODE AND THE APPROVED PLANS (OBTAIN SAMPLE OF COMPLIANCE LETTER FROM CITY ENGINEERING DEPARTMENT) 2) AS-BUILT GRADING PLANS 3) REPORT FROM THE SOILS ENGINEER, WHICH INCLUDES RECOMMENDED SOIL BEARING CAPACITIES, A STATEMENT TO THE EXPANSIVE QUALITY OF THE SOIL AND SUMMARIES OF FIELD AND LABORATORY TEST, THE REPORT SHAL ALSO INCLUDE A STATEMENT BY THE SOILS ENGINEER THAT THE GRADING WAS DONE IN ACCORDANCE WITH THE REQUIREMENTS AND RECOMMENDATIONS OUTLINED IN THE PRELIMINARY SOILS REPORT AND ANY SUPPLEMENTS THERETO. 4) REPORT WITH AS-BUILT GEOLOGIC PLAN, IF REQUIRED BY THE CITY 34. UNLESS A GRADING PERMIT FOR THE PROJECT IS ISSUED WITHIN ONE (1) YEAR AFTER THE CITY ENGINEER'S APPROVAL, THESE PLANS MAY BE REQUIRED TO BE RESUBMITTED FOR PLANCHECK. PLANCHECK FEES WILL BE REQUIRED FOR SUCH RECHECK. 35. THE SOILS REPORT TITLED PRELIMINARY GEOTECHNICAL INVESTIGATION UPDATE REPORT DATED JULY 7, 2004, SECOND UPDATE "PRELIMINARY GEOTECHNICAL INVESTIGATION REPORT DATED JUNE 5, 2012, ADDENDUM GEOTECHNICAL PLAN REVIEW DATED SEPTEMBER 9, 2014 AND ADDENDUM SOUTHERN PROPERTY MARGINS HILLSIDE TOE RETAINING WALLS, PROPOSED LA COSTA VILLAS DEVELOPMENT DATED NOVEMBER 17, 2014 SHALL BE CONSIDERED AS PART OF THE GRADING PLAN, ALL GRADING SHALL BE DONE IN ACCORDANCE WITH THE RECOMMENDATIONS AND SPECIFICATION CONTAINED IN SAID SOILS REPORT. SOILS ENGINEER'S CERT/FICA TE I, SEYED. SAMSAM SHARIAT, A REGISTERED GEOTECHNICAL ENGINEER OF IHE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SO ILS MECHANICS, HEREBY CERTIFY THAT A STUDY OF THE SOIL CONDITIONS PREVALENT WITHIN THIS SITE WAS MADE BY ME OR UNDER MY DIRECTION ON THE DATES OF SEPTEMBER 6, 2014 THRU SEPTEMBER 9, 2014. TWO COPIES OF THE SOILS REPORT COMPILED FROM THIS STUDY WITH MY ~;;-_ RECOMMENDATIONS HAVE BEEN SUBMITTED TO THE OFFICE OF THE CITY i~ ENGINEER. S J).MS441 J' <'.)~, . ~ o/~ SMS GEOTECHNICAL SOLUTIONS, INC. ,CJ (;} 2885 ~ M 1645 s. RANCHO SANTA FE ROAD, SUITE 208 ,1:" G:i 12/31/14 ,;: ISB SAN MARCOS, CALIFORNIA 92075 -1( u1 E,p. -, * (760) 761-0799 JI G'~ e,+' / . __ 1 . 'f /' 0 T[c r\l'\ ~'<' ,. I (?) -t , ·--,. ") --(;' Op C/>.'1..\'<0~ SIGNEDq'/,~.___.....c _ ___/ DATE: / 2. -3 -f 4 6£ 1).8'.E. NO.:,,l-l __,,,:2=&8.=5~----- REGISTRATION EXPIRATION DATE: OWNERS CERT/FICA TE I (WE) HEREBY CERTIFY THAT THE REGISTERED SOILS ENGINEER OR GEOLOGIST HAS BEEN OR WILL BE RETINED TO SUPERVISE OVER-ALL GRADING ACTIVITY AND ADVISE ON THE COMAPCTION STABILITY OF THE SITE. MBM DEVELOPMENT. INC SOURCE OF TOPOGRAPHY TOPOGRAPHY SHOWN ON THESE PLANS WAS GENERA TED BY PHOTOMETRIC METHODS BY GROUND CONTROL SET IN 2003 BY MASSON & ASSOC., INC AND FLOWN IN 2004 BY SAN-LO AERIAL SURVEYS AND WAS UPDATED BASED ON THE FIELD SURVEY IN 2013 BY SURVEYOR KARL CEBE TOPOGRAPHY SHOWN HEREON CONFORMS TO NATIONAL MAP ACCURACY STANDARDS. PROJECT LOCATION THIS PROJECT IS LOCATED WITHIN ASSESSORS PARCEL NUMBER(S) ASSESSORS PARCEL No.: 216-300-04-00 THE CALIFORNIA COORDINATE INDEX OF THIS PROJECT IS CALIFORNIA COORDINATE No. 1977-6256 LEGAL DESCRIPTION: LOT 401 OF LA COSTA SOUTH UNIT NO. 5, IN THE CITY OF CARLSBAD, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. 6600, FILED IN THE OFFICE OF THE COUNTY RECORDER OF SAN DIEGO COUNTY, MARCH 10, 1970. BENCH MARK DESCRIPTION: CLSB-020 ROD DRIVEN TO REFUSAL W/ CAP MK'D L.S. 6215 LOCATION: 5.0 FOOT BACK OF CURB ON THE SOUTH SIDE OF LA COSTA AVENUE 220 FEET WEST OF ROMERIA STREET RECORDED: R.O.S. 17271 ELEVATION: _ __,_IO-,c4"".2""5'-----~DATUM: N.G.V.D. OF 1929 EARTHWORK QUANTITIES CUT: FILL: IMPORT: 951 CY 120 CY VICINITY MAP CITY OF OCEANSIDE OWNER MBM DEVELOPMENT, INC. 1603 LAKE DRIVE 7& LOT 401 GIBRALTAR ST. APN 216-300-04-00 NOTTO SCALE CITY OF VISTA EXPORT: TOTAL 0 CY 831 CY 951 CY CARDIFF, CA. 92007 n s1GNED:-"'M-'-'1 __ ~'"''""·-v-•,..• ____ DATE: ,-z.1,1.( \4 REMEDIAL 774CY DECLARATION OF RESPONSIBLE CHARGE I HEREBY DECLARE THAT I AM THE ENGINEER OF WORK FOR THIS PROJECT, THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION ~703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND TIIAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BY THE CITY OF CARLSBAD DOES NOT RELIEVE ME AS ENGINEER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. ACE CIVIL ENGINEERING CONSULTING ENGINEERS 7668 EL CAMINO REAL #104-463 CARLSBAD, CA 92009 661,260.3422 ,._ 0 BY: r),.,,.-; , ,,,.,-n...,~ ~ MIKE M. MASSOODNIA R.C.E. NO.: 40922 REGISTRATION EXPIRATION DATE: MARCH, 2015 DEVELOPER RANCHO FARMS CONSTRUCTION MAJID MORTAZAVI 1603 LAKE DRIVE CARDIFF, CA. 92007 (858) 603-1763 INDEX OF SHEETS I. COVER SHEET -WORK TO BE DONE, LEGEND, NOTES. 2. CONTINUED NOTES 3. GRADING PLAN 4. SECTIONS 5. DRAINAGE PLAN 6, DETAILS 7. DETENTION BASIN DETAILS _____, ..--....~_.____._~ --1<=. ) Rt'r"Al Nll'iC: WALL ·t>~Till!.S /fl'ID N'OT f.S _S ft.E,-AlN1rlQ w,ttl '0.ETiHL.S _/ -.....-....______.._..~. CIVIL ENGINEER .& ACE CIVIL ENGINEERING CONSULTING ENGINEERS 7668 EL CAMINO REAL# I 04-463 CARLSBAD, CA 92009 (661 I 260-3422 LEUCADIA WASTEWATER DISTRICT PUBLIC SEWER SYSTEM APPROVAL . 6 APPROVED BY: LWD DISTRICT ENGINEER /, ,tlf.>¼J(~ 26s1f:_ l'?f(t t'/: STE HEN □EERIN~ RCE oAE 1 ft .PttoEJr-ii..1,, ,)- FIRM EXP1DAlE WORK TO BE DONE THE GRADING WORK SHALL CONSIST OF THE CONSTRUCTION OF ALL CUTS AND FILLS, REMEDIAL GRADING. ORAINAGE FACILITIES, EROSION CONTROL FACILITIES, AND PLANTING OF PERMANENT LANDSCAPING AND PREPARATION OF AS-BUILT GRADING PLANS, AS-BUILT GEOLOGIC MAPS AND REPORTS, ALL AS SHOWN OR REQUIRED ON THIS SET OF PLANS AND THE CITY STANDARDS, SPECIFICATIONS, REQUIRMENTS, RESOLUTIONS AND ORDINANCES CITED ON THESE PLANS. THE GRADING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE FOLLOWING DOCUMENTS, CURRENT AT THE TIME OF CONSTRUCTION, AS DIRECTED BY THE CITY ENGINEER. 1. CARLSBAD MUNICIPAL CODE 2. CITY OF CARLSBAD ENGINEERING STANDARDS 3. THIS SET OF PLANS 4. CIIY OF CARLSBAD PLANNING COMMISSION RESOLUTIONS NOS. 7052 DATE;D 6/24/2014 5. THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (GREEN BOOK). 6. SOILS REPORT AND RECOMMENDATIONS BY SMS GEOTECHNICAL SOLUTIONS, INC. 1645 S. RANCHO SAN TA FE RD,, STE 208, SAN MARCOS, CA 7 60-7 61-0799 DATED: NOVEMBER 17, 2014 ~ ,;;e,n, G\, t~l•t 7. THE SAN DIEGO AREA REGIONAL STANDARD DRAWINGS AND AS MAY BE MODIFIED BY THE CITY OF CARLSBAD STANDARDS. 8. CALIFORNIA COASTAL COMMISSION DEVELOPMENT PERMIT CONDITIONS DATED: _._N.,,/A_.,. __ _ AND COASTAL PERMIT #: N/A DATED: N/A. 9. ENVIRONMENTAL APPROVAL DOCUMENTS DATED: _N~/A ____ _ 10. TIER 2 STORM WATER POLLUTION PREVENTION PLAN PREPARED BY: SW14-309 11. THE CALIFORNIA STORM WATER QUALITY ASSOCIATION {CASQUA), STORM WATER BEST MANAGEMENT PRACTICE, CONSTRUCTION HANDBOOK AND STATE OF CALIFORNIA DEPT. OF TRANSPORTATION, CONSTRUCTION SITE BEST MANAGEMENT PRACTICES (BMP) MANUAL. LEGEND DESCRIPTION PROPERTY LINE 6" CURB PERVIOUS DRIVEWAY NEW CONCRETE WALKWAYS DWG. NO. SDRSD G-1 SYMBOL p L QUANTITY 150 Lf 3,080 SF 1.070 sf 4" PVC SEWER SDR-35 {PRIVATE) 4" PVC SEWER LATERAL (PRIVATE) LWDS-17,S-18 ----(S)----{I) 160 LF ~-~WER CLEANOUT (PRIVATE) EXISTING SEWER MAIN EXISTING SEWER LATERAL EXISTING WATER MAIN TRENCH RESURFACING LWDS-17,S-18 (L)~ 8 LWD S-8, S-9, S-25 (S)--~ 1 ~ - --(S)-- - -·-(ESL)-·- CMWD 169-4 -----{W)-- - - CITY STD. GS-25,26,27,28 ~ 200 SF I" IRRIGATION SERVICE I" METER UNIT I -8 FIRE SERVICE W /DDCV PAD ELEVATION FINISH FLOOR ELEVATION EXISTING CONTOURS PROPOSED CONTOURS EXISTING CONCRETE DITCH CMWDW-3 CMWDW-3A CMWD W-22 DETAIL C/6 6" & 8" HDPE HANCORE SURLOCK STORM DRAIN {PRIVATE) 12" TRENCH DRAIN 18" Xl8" CATCH BASIN@ DETENTION BASIN DETAIL E/7 2-4" HDPE dia. W/18" X18" CATCH BASIN DETAIL F/6 12" Xl2" CATCH BASIN LANDSCAPING 12" Xl2" CATCH BASIN AT WALKWAYS 4" dia LANDSCAPE DRAINAGE DETAIL D/6 DETAIL J/6 DETAIL B/6 GRADED SLOPES ~- SITE RETAINING WALL PER SHEET 8 /l,\ (DE)'~~:0 SITE RETAINING WALL SDRSD C-2 & C-3 BUILDING RETAINING WALLS (NOT PART OF GRAD/NG PERMIT/ (BUILDING RETAINING WALLS ARE PERMITTED UNDER THE BUILD/NG PERMIT CURB OUTLET EXISTING SIDEWALK REMOVAL AND NEW DRIVEWAY PERFORATED PIPE SDRSD DWG D-25 SDRSD G-14F I SH1EET I FG 96.92 FF 97.42 -· -· '••··(102) .. -·" 93 __ _ - - - [] □ 11111 □ 0 y y y 270 LF . I 5 3 2 f~.J.JJ.• ... t.1111,P.JU:f 1702 SF =-1 M M M 694SF -c::_r-,,-..,---.._,-,~ ( :p::.t<=,m:•.!Fl~Zll"'f 155 LF . ....._____ __ '--""---'· .1), =(l!I : : I 35LF I 85 SF- CITY OF CARLSBAD ENGINEERING DEPARTMENT GRADING PLANS FOR: LA COSTA VILLAS TITLE SHEET 1608 LAKE DRIVE CARDIFF, CA. 92007 ~UILT" i'Jii;, 1, -CITY OF CARLSBAD FIRE DEPARTMENT ~ho/un.1 0'3-!'1-2< 15/f'". /\\ KE.VISE '6v.,l1)11'1G _F<CrPtlNT I ·-<.•2$•1< -::J,I. ( -, SHEETS J I g I ~ 11::, PUD 13-I I (858) 603-1763 Q ';l:1 '1-i'I sq 7 ""Ii,, t 1<>1-'?, REQUIREMENTS: RE.Vt1!o"E RE Tr\ 1N,N(; ,,.,,, U.5 APPROVED=/1, f/0' 1-JASON S. GELDERT SIGNED: __.Ll.._., =-c~--~=-~-;:~;~ ___ DATE 1 ?_/ 5µ.fi EXP. DATE .A---~£:T')IIN"INC WALL on·..tu. 'v .. c' A ,.; , I ~i I JI ,2,,2.,11..f NO. OF F.H.(S) F.FLOW G.P.M. OUT OF __ F.H.(S). .fl OPEO s~ e.~ ·r 'j Ri: TAH1h{.;-WA-\.\. r,e·rAJ!C ENGINEERlpr{G MANAGER REC 63912 EXPIRES 9/30/16 DATE --RE1~ Jf~!li• BLDG. SPRINKLED: YES F.FLOW G.P.M. /1\ .le.v1<:E ?RIVA'!'S sroRM -ORAIN DWN BY: I PROJECT NO. I DRAWING NO. \ --,fl LJ4,. DA."E INITIAL DATE INITIAL DATE INITIAL CHKD BY: CT 13-06 483-2A ~-REVISION DESCRIPTION ENGINEER OF WORK OTHER APPROVAL CITY APPROVAL RVWD BY: INSPECTOR FIRE MARSHAL DATE \ 'i \ ·----~-- r '15 '\ . ' ' , STREET NOTES 1. ACTUAL STRUCTURAL SECTIONS WILL BE DETERMINED AFTER "R" VALUE TESTS HAVE BEEN CONDUCTED BY A PROl'ESSIONAL ENGINEER OF THE STATE OF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOIL MECHANICS, ON THE PREPARED BASEMENT SOIL. THE "R" VALUE TESTS AND THE ENGINEERED STRUCTURAL SECTION MUST BE SUBMITTED TO THE ENGINEERING INSPECTOR FOR REVIEW AND APPROVAL A MINIMUM OF TWO (2) CITY WORKING DAYS BEFORE THE WORK BEGINS. 2 . STREET LIGHTS SHALL BE INSTALLED AS SHOWN ON THESE PLANS, UNDERGROUND CONDUIT RUNS, SERVICE POINTS AND HAND-HOLES SHALL BE SHOWN ON THE "AS-BUILT" PLANS. NO DIRECT BURIAL STREET LIGHT FOUNDATIONS WILL BE ALLOWED. ALL LUMINAIRES SHALL BE "CUT OFF" TYPE. 3. ALL UNDERGROUND UTILITIES AND LATERALS SHALL BE INSTALLED PRIOR TO CONSTRUCTION OF CURBS, CROSS GUTTERS OR SURFACING OF STREETS, 4. WHERE AN EXISTING PIPE LINE IS TO BE ABANDONED IT SHALL BE REMOVED WITHIN TWENTY FEET OF BUILDING OR STREET AREAS AND REPLACED WITH PROPERLY COMPACTED SOILS. IN OTHER AREAS THE PIPE WILL BE PLUGGED WITH CONCRETE OR REMOVED AS APPROVED BY THE CITY ENGINEER. 5. WHEELCHAIR RAMPS SHALL BE INSTALLED PER REQUIREMENTS OF TITLE 24, CALIFORNIA ADMINISTRATIVE CODE. 6. STREET TREES SHALL BE INSTALLED PER SECTION IV D.3 OF THE CITY OF CARLSBAD LANDSCAPE MANUAL. 7. FIRE HYDRANT MARKERS SHALL BE PLACED IN THE STREET WITHIN THE LIMITS OF WORK OF THIS PLAN PER SDRS DWG M19. 8. ALL SURVEY MONUMENTS AND POINTS THAT ARE DISTURBED BY THIS WORK SHALL BE REESTABLISHED, PERPETUATED, AND DOCUMENTED PER THE PROFESSIONAL LAND SURVEYORS ACT. 9. TWO (2) SETS OF SURVEY (CUT) SHEETS SHALL BE PROVIDED TO THE CITY ENGINEERING INSPECTOR. WATER NOTES l. WATER & RECYCLED WATER MAIN AND APPURTENANCES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE "CITY OF CARLSBAD ENGINEERING STANDARDS" (LATEST EDITION) VOLUMES 2 & 3. 2. THE CONTRACTOR SHALL OBTAIN AN EXCAVATION PERMIT FROM THE DIVISION OF INDUSTRIAL SAFETY BEFORE ANY EXCAVATION AND SHALL PROVIDE PROOF OF OSHA NOTIFICATION AND SHALL ADHERE TO ALL PROVISIONS OF THE STATE CONSTRUCTION SAFETY ORDERS. 3. BEFORE ANY CONNECTION OR SHUT DOWN OF VALVES ON EXISTING C.M.W.D. LINES, A PERMIT SHALL BE OBTAINED FROM THE C.M.W.D. OFFICE AND MUST BE SIGNED AND APPROVED BY THE CITY OF CARLSBAD'S DEPUTY CITY ENGINEER AND THE UTILITY OPERATIONS' PUBLIC WORKS MANAGER. 4. A PRECONSTRUCTION CONFERENCE MEETING SHALL BE HELD A MINIMUM OF 7 DAYS BEFORE CONSTRUCTION BEGINS. THE CONTRACTOR SHALL NOTIFY THE CITY OF CARLSBAD ENGINEERING INSPECTION 48 HOURS PRIOR TO BEGINNING OF CONSTRUCTION, TELEPHONE N0.(760) 438-3891 FOR SCHEDULING. 5. THE CONTRACTOR SHALL NOTIFY THE CITY OF CARLSBAD ENGINEERING INSPECTION DEPARTMENT 48 HOURS PRIOR TO STARTING WORK SO THAT INSPECTION MAY BE PROVIDED -TELEPHONE NO. (760)438-3891. 6. NO TREES OR STRUCTURES SHALL BE ALLOWED IN THE WATER LINE EASEMENT, ALL EXISTING TREES AND STRUCTURES SHALL BE REMOVED PRIOR TO COMMENCEMENT OF WORK -ANY EXCEPTIONS SHALL REQUIRE WRITTEN PERMISSION FROM THE DISTRICT ENGINEER. 7. ALL BURIED COPPER PIPING AND APPURTENANCES SHALL BE PROTECTED BY MEANS OF CATHODIC PROTECTION. IF DEVELOPER/OWNER CONDUCTS A SOILS TEST REPORT AND DEMONSTRATES THAT PROTECTION CAN BE PERFORMED IN ANOTHER MANNER, THE DISTRICT ENGINEER WILL CONSIDER AN ALTERNATIVE FORM OF PROTECTION. 8. THE EXACT HORIZONTAL AND VERTICAL ALIGNMENT AND TYPE OF MATERIALS OF THE FIRE LINE LOCATED BETWEEN THE DETECTOR CHECK VALVE AND BUILDING SHALL BE DETERMINED BY THE CITY OF CARLSBAD FIRE MARSHAL. 9. ALL POTABLE WATER AND RECYCLED WATER SERVICES SHALL BE 1" AND ALL METERS SHALL BE 5/8" (UNLESS OTHERWISE NOTED ON PLANS}. 10. ALL WATER METER BOXES SHALL BE 17" X 30" X 12" POLYMER CONCRETE AS MANUFACTURED BY ARMORCAST OR EQUAL. 11. MINIMUM SPACING BETWEEN POTABLE WATER LATERALS AND SEWER SERVICES SHALL BE 10 FEET. "' 12. THE TOP OF WATER METER BOXES SHALL BE FLl)SH WITH THE FINISHED SURFACE GRADE. .· 13. CONSTRUCTION OF WATER MAINS AND RECYCLED WATER MAINS SHALL ADHERE TO THE "CRITERIA FOR THE SEPARATION OF WATER MAINS AND SANITARY SEWERS" PUBLISHED BY THE STATE OF CALIFORNIA'S DEPARTMENT OF HEAL TH SERVICES. 14. AXIAL DEFLECTION AT THE PIPE JOINTS ARE NOT ALLOWED: THE USE OF A HIGH- DEFLECTION COUPLING AT A PIPE JOINT MAY BE PERMITTED BY THE INSPECTOR ON A CASE BY CASE BASIS NOT TO EXCEED 4 DEGREES TOTAL DEFLECTION PER COUPLING (2 DEGREES/EACH GASKET). USE CERTAINTEED "VINYL-IRON" H.D. FOR C900. LWD SEWER GENERAL NOTES: STANDARD SEIJl/f:R LATE:RAL NOTES.FOR MINOR GRADING PLANS 1. LWO APPROVAL OF THESE PLANS DOES NOT RELIEVE THE APPLICANT, PRIVATE: ENGINS:ER OF WORK., OR COl'ITRACTOR FROM RESPONSIBILITY FOF\ THE CORRECTION OF ERRORS ANP QMI$SIONS DISCOVER.ED DURING OR AFTERCONSTRUCTION. 2.1\LL bi;$IGN, MATERIALS, AND CONSTRUCTION WORK SHALL.CONFORM TO THE Li:liCADiAWAST)S.VI/ATER DISTRICT 1.WD Si;WERST(INDARDS AND TO THE REQUIREMENTSQF THE ST_AND(IRD.SPECIFICATIQNS FORPiJBUC l",ORKS CONSTRUCTION (.GREENBOOK)AND THE REGIONAL STANDARD DRAWINOS, MOST CURREl':ff EOITIONS. IN THE EVENT OF CONFLICTTHELVVD SEWER STANOAAOS GOVERN '.J OSHA $AE9TY ORDERS AND OSHA GQNFINED SPACE; ENTRY REQUIREMENTS SHALL BE FOLLOWED AT ALL TIMES WITHOUT EXCEPTION. 4. THE CONTRACTOR $HALL HAVE A CQP'f OF Ttl.E DOCUMENTS SP6CIFIED IN SEW~RNOTES 2 & :l ON THE )OBSITE AT ALL TlfAES, o. Tf-1.E CONTRACTOR SHALL GUARANT!,E All WORK FORA PERIOD OF ONE Yi:AR t~ITi~!~~~%<~~~~EP7~~~::tc"'.~~:~ vt~tJ1~t;:~~o 10R MATERIALS WITHIN THE ONE YEAR PERIOD WITHOUT EXPE,NSE WHATSOEVERTO LWO .. 6 Pg(OR TO BEGINNING. SEWER WORK, CONTRACTOR SHALL .SJ;;CUREA LWD PEf<l/1IT FOR CONSTRIJCTION AND SHALL PROVIDE A MINIMUM OF 72 HOURS NOTICE TO·LWD PRIOR TO CONSTRUCTION. 7. APPRO\IAL OF THIS PLAN BY LWD .PQES NOT CONSTITUTE A REPRE'.SENTATION OF THE ACCURACY OF THE LOCATIOt-1 Of, OR HIE EXISTEN<;E OR NON EXISTENCE OF,ANY UNDERGROUND UTILITY, PIPE, OR STRUCTURE WITHlt-1 THE LIMITS OF THIS PROJECT. 8 .. ALL REVlglONS IQ DRAV'IINGS SHA.LL BE APPROVED BY THE LWD DISTRICT ENGINEER IN WRITING PRIOR TO CONSTRUCTION. ij. CQNNECTIQNS TO EJ;ISTINO SEWER PIPE OR MANHOLES SHALL ONLY BE DO.NE INTHE DIRECT PRESENCEOFTHELWD INSPECTOR. NEW SEWER SHALLNOT BE CONNECTED OR ALLOWED TO FlOW TO EXISTING SEWER UNTIL AFTER FINAL ACCEPTANCJc OF ALL UPSTREAM WORK 8Y THE LWD INSPECTOR, OR AS APPROVED BY DISTRICT ENGINEER. 10. ALL SERVICE LATERALS SHALL BE LOCATED AT RIGHT ANGLES TO THE SEWER /MIN UNLESS OTHERWISE SHOWN AS APPROVED BY LWD ON THE PLANS. 1tA2·INCH.H.IGH "S" SHALL BE INSCRIBED ON THE CURB FACE ATEACH LATERAL LOCATION BY THE CONTRACTOR·. 12, A1.0 Q/')G.E SHIELDE;P COPPER V\!lflE $HALL BE BURIED QVER EACH LATERAL THE V'IIRE Sf\A,LL EXTENP UP 10 /\2" .COPPER TAG TIEO AND SOLDERED TO THE WIRE. Tl-jE; TAG OVER THE SEWER MAlN SIJALL TERMINATE 6." ABOVE PAVING SUBGRADE WllH FINAL LOCATION JUST BE!,OW PAVING. THE TAG OVER THE CUSTOMER ENO OF THE LArERAL SHALL EXTEND AOOVE GRADE UNTIL CONNECTED ANO SHALL THEREAFTER. SE BURIED AT THE POINT OF CONNECTION. 13. ALL LATERALS SHALL SE CONSTRUCTEO CLEAR OF DRIVEWAYS. 14. ALJ.S~WER$AND LATERALS SHALL BE WAYNE BALLED OR JETTED, LOW PR!2SSURE AIR TESTED, AND TELEVISED AT THE APPLICANT/CONTRACTORS EXPENSE PRIOR TO CDNSID.ERATIQNfOR FIWILACCE.PTANCE BY. !..WO. AIR TEST SHALL BE DONE AFTER CONSTRUCTION OF ALL OTHER UTILITIES ANO UTILITY LATERALS. 15. A.LL SEWERS AND LATE:RALSSHAJ;L BE IN PLAClci AND SHALL HAVE FINAL APPROVAL BY THE LWD INSPECTOR PRIOR TO PAVING. 16. ALL.NEW C:ONt-lECTION.STO EXISTING SEWER SHALL BE MADE TO EXISTING WYES, MADE WJTH GASKETED PVC SADDLE WYE, OR SHALL BE MADE 6Y IN<iTALLING NEW MANUFACTURED WYES. FOR INSTALLING NEW Ml'NIJFACTIJRED WYES, STANDARD BELL AND SPIGOT OR PLAIN END WIES AND PLAIN END PIPE SPOOLS MATCHING THEADJACE'NT 17.EXISJING PIPE MAYBE USED FOl"l. lNSERTINQ.WYES INTOAN .EXISTINGSEl",ER. ALL CONNECTIONS NOT MAOE TO EXJSTING WYES MUST 6E IN ACCORDANCE WITH .LVVP. i;ITANOARD DRAWINQ S,32. IF'NECESSARY DURINGTHE LATERAL CONNEQTION WORK, UPSTREAM FLOW IN l'HE EXJ STING SEWER SHALL BE TEMPORARILY PLUGGED AND BY-PASSED BY PUMPING OR PUMPER TRUCKS FOR DISPQSALTOAl:)OWNSTREAM LW.D SEWER IN LQC(\Tlm!S WITtl SIONIFICANT UPSTREAM FJ.OW, L\/\/D MAY REQUIFlE TEMPORARY PROVISION OF DUTYANP BYPASS EQUIPMENT WITH FUlL-TIME MANNED MONITORING. NO Ur-I MANNED BYPASS SHALL BE ALLOWED. 16, FOR CONNECTlON OF PLAIN END TO PLAIN END PVC SEWER., REPAI.R COUPLINGS SHALL BE MADE OF PVOMATERIAL MEE;TING THI; SAME MATERIAL REQlJIREMENTS ASTHE PIPE BEIN<, REPAIRED. PVC SEWER REPAIR COUPLINGS SHALL BE RUBBER GASKETE[) WITH NO .GENTER STOP, PIPE ENOS SHALL BE THQROI.JQHLY CLEANE.D PRIORTOJNS.TALLATION OF THE REPAIRCOUPLING(S). ~&!:!i~r~g~~!Nif~~~~gJ!iifii~A{~g~ilr,~~~i;:~ BETWEEN THE T'I\IOPLAINEND PIPE$, PVC SEWER REPAIR COUPLINGS SHALL BE. AS MANUFACTURED BY PW PIPE OR EQUALAPPROVED BY THE LWD DISTRICT ENGINEER. 19. PVC OR VITRIFIED CLAY PIPE (VCP}SEWER PIPEANDWYES MAY BE USED TO TIE-IN TO EXISTl>IG VCP, FOR coN.NEC"flOl>IQR REPAIR OF PLAIN ENPVCP TO VCPAROMAC INDlJSTRloS, INC. STYLE $01 COUPLING OR EQUALSHALL BE USt:D. FOR CONNECTIONS OF VCP TO P\JC, A ROMAG INDUSTRJES, INC. STYLE RC 601 REOUCIJ:lG COUPLING WITH MATCHIN.0 INVERTS, OR APPROVED EQUAL, SHALL BE USED WITH A 01\SKET RANGETO MATCH 1'JE OUTSIDE DIAMETER OF THE PIPE ON TIJAT SIDE OF THE COUPLJNG BEING JOINEQ. THE CENTlcR RINGS SHALL BE DUCTILE IRON PER AST.M A536, GRAQE 66-46-12 AND SHALL BE PROVIDED WITH 16 MILS FUSION BONDED EPOXY COLOR COOED TO THE TYPE OF <::ONNEGTiNG PIPE, GASKETS SHALL BE SBR PER ASTM 0.000 (ABll710, <;Q;,tp<:JUl'/DED FOR WATER I\NffSE'/1/ERSERVICE. ALL NUTS AND BOLTS SHALL BE TYPE 31e STAINLESS STEEL. 20 fl.NALAPPROVAL OF PLAN$ ~Y.DISTRl(;T ENGINEER I.S VALID FORA PERIOD OF TIME NOTTO EXCEED ONE YEAR FROM APPROVAL DATE TO START OF CON.STRUCTION. IF THE ONE YEAR TJME LIMIT IS EXP!RlaD PRIOR TO STAAT OF CON.STRUGTION THE DEVELOPERSl-ll\Ll. RESU~IT THE PLAN CHECK TO THE DISTRICT ENGINEER FORAN UPDATED REVIEW ANO APPROVAL. ANY CHANGES REQUIREO TO THE PLANS SHALL BE MAOEAT THE OE\IELOPERS EXPENSE ANO APPROVED BY THE: LWD DISTRICT ENGINEER PRIOR TO THE START OF CONSTRUCTION. ........ ~··· ··•-· .. "'-·'-,_ "AS BUILT" ~#=-P.~. :/-:l'lt"'f EXP. 't/;o/u,g '1/wli...u DATE -"' INSPECTOR f o/,TE 1-----+----+------------------j---j-------,l----+-----1 I s2ET I ci1~,N2,~G~P~T~,~~BAD W ~ 1------+--+------~-----------+---+-----t----+---1 :====-'=;;:============~-'===~ ,, . .. 3/25/2015 ( 1,,/ /., /1\ THIS SHEET REPLACES SHEET 2 APPROVED ON 12/12/2014 DATE INITIAL REVISION DESCRIPTION DATE INITIAL DATE INITIAL ENGINEER OF WORK OTHER APPROVAL CITY APPROVAL GRADING PLANS FOR: ' ' ' LA COSTA VILLAS NOTES APPROVEZD,Y ) I I ~,.,,,: ;-r---, JASON s. GELDER! -~~'.":c'......,W:vl~,~/~,v~1.l/r:.___' ____ 3 125 • 15 CITY ENpiNEER REC 63912EXPIRES 9/30/16 DATE OWNBY: CHKD BY: \:f/. RVWDBY: ~~~ PROJECT NO. CT 13-06 I DRAWING NO. _ 483-2A , / O ' ~- "' G).; O.i:., ..., 0:, (0 (.,J I "': )>' .,, _, 9500BW FF 97.67' PAD 97 17' UNIT 4 FFG. 97.17' PAD 96.67' PR LINE SEE RETAINING WALL DETAIL 'A' ON SHEET #8 '--------+--1----l--1- ) ' I ~ --------LINE OF SIGHT ._____, 'lll'.JcQ_R SOUTH B UNDTRA 0 -- ) I I I j I ', SH ET5 OR I~ RE RT 1 ST1RM RAIN I p N I I I I I ! (t) Pust,c SIDEWALK I G 169-4 ii,' I ~ ' I I I --I ! i,.,--(S1'--j__ (E) LWD SMH#10-1845 INV=96.79" XISTING S WER LINE I ~ '6, "' -',\ ~I 1' ' FF. 96.92' PAD 96.42' FF. 96.25' PAD 95.75' SHEET 7 8 . ~ ·-.;, IP--... "' UNIT2 FFG. 95.75' PAD 95.25' UNIT 1 FFG. 95.08' PAD 94.58' "\~ ~~ j( ' ti . • -I_ • Lll UNT6 FFG. 5.33' PAD .83' FULL PORT 4";,,' MAINLINE BACKFLOW DEVI #4963 ABS COMB FULL PORT 4" t MAINLINE BACKFLOW DEVIC #4963 ABS COMBO I U \T 5 FF . 95.08' PA 94.58' (E) P BLIC SIDE ALK I (N) DRIVEWA PER 24' CARLSBAD DRIV~ G-14F0, ,,;y1..,.,..,r- (W)--7'----~-I---&• ~ (W) <O ill s ~ :5 C .NNECT TO (El PRIVAT S1ER LATERAL PER L S-17, S-25 tD S-3~ \ ,l ( _C~R GIBRALTA -_ STREET ---bl a:: I ~ ~ i;; ill I F p F . 95. 3' p D 1 FF.9 AD .67' GIBRALTAR STREET -!;, C/L FOR GIBRALTA -- I In C.L. TO L LENGTH .. ------REMEDIAL SLOPE GRADING PER SOILS ENGINEER REFER TO SHEETS FOR STORM DRAIN PLAN DRIVEWAY REVISE BLD'G RE . WALL TO MATCH RET. WALL ON BUILDING PLAN 109.00TW ~ SD S C 2 B ' REFER TO SHEETS FOR STORM DRAIN PLAN 108.70 TW SDRSD C-2 _&. I \ \ \ I \ L .L-c-" ____ _ - '-' ' ' ~-~ ' 6'CURBLINE -----, ~ INSTALL 1 EA -\ . 6" DOUBLE CHECK VALVE ASSY PER (E) DRIVEWAY LINE OF SIGHT 165' FOR NORTH BOUND TRAFFIC ) --W-22 6" FlxPJ G.V. 8"!8" X 6" TEE & T.8. ,:, ~-----l-~ ILT' STREET ---- EXP. I Fl LD VERIFY EXIST WYE SIZE OF 6" DIA. C NNECTED TO EXISTING WYE. IF FOUND WYE IS NOT 6" DIA. THEN REMOVE AND REPLACE Wt!rH 6" DIA. WYE PER LWD EWER GENERAL NtjTES AND LWD STANDAR SPECIFICATIONS. (S)--==+/J:_:cn f..;~;i\~~-~l_~_ t'ii'i-=~~~ FIRE PUt= 148.5' (S) EXISTING 8" SEWER L ~- E • 0 I I t ;:a, I INSPECTOR GRADING PLAN SCALE: 1" = 10'..Q" O' 2' 4' 6' 8' 10' 20' 30' 40' ~ I I I ,:n &/ teil.l - 03-25-2015 ff.#¥, 1 REVISE BUILDING FOOTPRINT 'f/wu1..1 REVISE RETA1NlNG WALL SLOPE REMEDIAL GRADING PER SOILS ENGINEER. DATE NEW SHEET REPLACES SHEET 3 APPROVED 12-12-2014 NEW SHEET 9 ADDED DATE INITIAL REVISION DESCRIPTION ENGINEER OF WORK 50' I \ - NOTES: NORTH SITE RETAINING WALLS ARE UNDER THIS GRADING PERMIT AND PERMITTED PER THIS PLAN BUILDING RETAINING WALLS ARE UNDER THE BUILDING PERMIT DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL CITY OF CARLSBAD ENGINEERING DEPARTMENT GRADING PLANS FOR: LA COSTA VILLAS GRADING PLAN CITY EN OWNBY: CHKD BY: <.f/-PROJECT NO. CT 13-06 RV'ND BY: JASON S. GELDERT 3,zs ,1s DATE DRAWING NO. 483-2A • 043015 "' 0 S' "' N 8 F.F. 107.42' / F.F. 97.42' .. ' . . . . . ' PLANTER CRIB WALL, 3' MAX. EX. GRD. --, FG>c'.'.:./ ;2-- 3Je'SLOPE ~I -~-----ll~ 0 PROP. CONC. DITCH PER D-75 RETAINING WALL PER ~-DETAILA/8 10'-0" HEIGHT PERMITTED WITH GRADING PERMIT ., Y / ·» ~~X RETAINING WALL , / /, ' . . 1/ / '" PERMITTED WITH • "--/ • ""---~ THE BUILDING PERMIT • SECTION A-A SCALE• l/4"= l'-0" F.F. 107.55' 12" WIDE X 3" DEEP TROUGH SLOPE TO ~-fl+CATCH BASIN OSED ,. • F.F. 96_.05' PACTED FILL ' EXISflNG GRADE PROP. (2)4" PER DRAINAGE PLAN ACTIVE ZONE -REFER TO BACKFILL NOTE ON SHEET#9 RETAINING WALL PER DETAIL B/8. PERMITTED WITH GRADING PERMIT SECTION D-D SCALE: 3/,/ = l '-0" '" ' 2% CONNECT FOUNDATION DRAINAGE TO BUILDING RETAING WALL DRAINAGE SYSTEM --.. SECTION 8-8 SCALE: l /4" = I '-0" REFER TO DRIVEWAY DETAIL H/6 FOR ADDITIONAL INFORMATION IT I~ i1~111 j JI c:: ·1 I 111 ,.:__-_---:-: -:-"-:[!d·t:'::'.·_·~_: _11:::n1 . 1mg1millmlg · --11 1c-=1 I 1=111 RETAINING WALL PER ' DETAIL A/8 \_ 10'-0" HEIGHT PERMITTED WITH GRADING PERMIT RETAINING WALL PER ("'r--Y--.Yy-,_ DETAIL D2/9 ' 10'·0" HEIGHT l PERMITTED WITH GRADING PERMIT EX. EASEMENT w z _J Ii 0 0:: a_ ·~ 71"--"--"'.........C?f"--PROP. 3' HIGH FENCE ON TOP OF WALL 12" WIDE X 3" DEEP TROUGH SLOPE TO CATCH BASIN _ __,.,,+!-_ F.F. 107.13' EX.GR F.F. 96.13' 0 RETAINING WALL PERMITTED UNDER BUILDING PERMIT PROP. 3' MAX. SDRSD C-2 &· 100.50 TW WALL PER BUILDING PERMrr------~ 97.17FF ~ , --~ EX. PAD 95.5 SECTION C-C SCALE: 1/4" = 1'-0" VERIES BETWEEN 17'-0" TO 29'-0" 15'-0" SETBACK --------···---·------------,% FIN. GRD. 2:1SLOPE~ EX. GRD. -....,✓- / 2% 7'-0" TO -----< DAYLIGHT PER SOILS REPORT (TYP) EX. GRD. \_ 1------+---+----~-----+------+-----1-~ ~ ~====-==========~=""r-1 CITY OF CARLSBAD ENGINEERING DEPARTMENT SHEETS 9 "AS BUILT" ~g-e,/u,/un,1 ~}:mq EXP. '7/",Q ,2.o .... ,, DATE 03-25-2015 if ./1. DATE INITIAL ENGINEER OF WORK 1 DELETED NOTE NOT APPLICABLE. REVISE RETAINING WALLS THIS SHEET REPLACES SHEET 4 APPROVED ON 12-12-2014 NEW SHEET 9 ADDED REVISION DESCRIPTION DATE INITIAL OTHER APPROVAL •25,/ 5 SS DATE INITIAL CITY APPROVAL GRADING PLANS FOR: LA COSTA VILLAS OWN BY: r, CHKD BY, Vr ~---RVWDBY: SECTIONS PROJECT NO. CT 13-06 DRAWING NO. 483-2A I / ' / . --~ '· 043015 -- ) I I i I ;T I " " " e (2) 4" BS @2 [ I UNIT4 UNIT 3 UNIT2 UNIT 1 ~Gm-"''~;..'~~ \'b ,to~ vJI,· 3' ' r . ~, s. :: 0 ' . §1 . gj . ... '.ffil ♦ :C.. ' ' io I r. : I ..... ~, I .. ,...::::,_,. -. •~··· "; .. --~--'-' X" -~-. , ' UJ' ~ I: :Z ' ~-,, ,.x_, 1· ), ~-.,. X ., y ' \.' I_,._.➔ -· ! ' ' _.<.,' ' 7 ' ' -,~::; ==::: :::· -_...:~ ABS '·: ' I , ' T g:2,00% St'QPt: -_._ __ ; . ' ' ' ' --·_ ---i:::: = : N ~? ~?• J4:·, E 63 9~~ '. ,· ' . (140)------ -'rr .... ~NT6 U T5 ----- DRIVEWAY INDICATED 12" X3" DEPRESSION IN SIDEWALK TO DRAIN T CATCH BASIN 6" ABS TYPE 'C' @50% LINE OF SIGHT ,ss· FOR NORTH ) STORM DRAIN PLAN SCALE: 1" = 10'-0" O' 2' 4' 6' 8' 10' ~ 20' I 30' I 40' I 50' I NORTH ~ 4' ~ _., (N) DRIVEWA PER ~ ·~ w I SHgEETS I EX/SY) Ga• s~;;;;;t;:::-:---/--/L~=f.«io~~~~"'+--CARLSBADDRIV G-14F,;:;; SIDEWALK ·11, ~,, CITY OF CARLSBAD WATER LINE IFIE-0 ~ UNDERDRAJ ~ (' f----+----+--------------------+-----+----+----+----, '-===''-'====•N=G=l=N=•·=·l=N=G=D=E=PA=R=TM=E=N=T=====~,_ ~ ... =_~.._=j...,.=_;~'!--1' ~G (W) -~ • r 0 • -1.,----(S1 - 1 : i --t-----~-&-j-'._ __ (W)-l--t-~gii· -+--_:~-J:lll---(W)J ,--______ \.:!.w~f~r~~S:~t~l~¼E s~:F==-""""'~.~.A~S~B~U~l~L~r~·---.---.~-=-1~=~~=~~=~1=~~=~~:~~=~~=~~=~~=~~=~~=~~=~~=~~=~~=~~=~~=~~=~~=~~~t~=~~=~3;~~=~~=r~=~~=~3;~~=~3~ GRADING PLAN~:RCOST A VILLAS - 7xiii,;s~Tl~N~G~S1W~E~R~L~IN~E4 ~~C/L~F~o~.R~G~IB;_RA~L~T~A~S~T~R~E~E~T:::::~--·-==i ==-·-=:-.: ~ ; "" [ 1f;k1~C -----,/u,124zr 3-25-2015 1 ~gg:~~~u~;~~~T:~~~~:1~,6~~~~~~s STORMDRAINPLAN GIBRALTAR)STREET <sJ ---. ----_ "' ~ c1LFOR G1BRALTA srR_E_Er_ -·-· :c-Yl£'f EXP. ,/so/z,13, □ATE rH1ssHEETREPLAcEssHEET5APPROVEDON -----,--L-===--=1~=-==--;~R~~+~~~:~~. -12-12-2014 CITY ENG! R REC 63912 EXPIRES 9/30/16 NEW SHEET 9 ADDED I JASON S. GELDERT 3,z5,15 DATE DRAW1NGNO. 483-2A ;043Q 15 i (11 G') 0~ """ cc, U>W I ' I N )> l 4" OR 6" GRATES BY ADS PRODUCTS < ✓ <l.. 41 FINISH SURFACE FLOW FLOW 1 DRAIN PIPE ... RISERS t;:;· OF PAVER DRIVE 4" OR 6" GRATES BY ADS PRODUCTS .A· .. /;., -, -, I 2 %> · · ·--_~,'-,-1----,L, ----1MwlN. ·"'-· .. --~ ,·~ -.. ,,. . _,,;._,uw n q •□□o □□□n 4" OR 6" DIA. PVC OR ABS PIPE CURB DETAIL -SDRSD G-1 A CATCH BASIN NOTTO SCALE NOT TO SCALE A--7 i ___ ~_L_-R/W ~~,- 1 I I I ...,,,,_~1.___,r -METER BOX (TYP) , I l" COPPER \ : SERVICE FORD C84-440 ,. : ~FORD Yl 1-474 (TYP) ____ :'.'''::s.,,,_,;:·s:·I,1~-~-FORD CF31-77 2" ANGLE METER STOP _ __,. 2" SERVICE------I I I I I A--..J DETAIL Yl 1-474 MANIFOLD NOTTO SCALE 8" C900 PVC ---W/ VALVE BOX & COVER ·~--BACKOF SIDEWALK 4'-6" 8" C900 PVC --+- W / VALVE BOX &COVER g l" COPPER -SERVICE METER BOX (TYP) 2" ANGLE ~-t-,-,..~R~--- METER STOP-~ FORD C84-440 SECTION A-A NOTTO SCALE "-----FORD Yl 1-474 • ...._ __ FORD CF 31-77 NOTES FOR 2" WATER SERVICE 1. INSTALL 2" COPPER SERVICE PIPE AND 2" ANGLE METER STOP PER W-4. ANGLE STOP SHALL BE LOCATED 12" MINIMUM BEHIND THE SIDEWALK, 30" BELOW FINISH GRADE. CONTRACTOR TO VERIFY GAS LINE FOR EXACT LOCATION. 2. INSTALL MULR SERVICE WYE (Yl 1-474 OR Y21-247) WITH BRONZE METER FLANGE CF 31-77 AND l" COMP X MIP ADAPTER C84-440. 3. INSTALL VALVE BOX AND COVER WITH 8" PVC WELL CASING PER W-13 OVER ANGLE METER STOP. 4. INSTALL l" SOFT COPPER SERVICE CONNECTION WITH l" ANGLE METER STOP AND METER OX AND COVER PER W-3. METER BOXES TO BE INSIDE RIGHT-OF-WAY WITH 6" SPACING BETWEEN BOXES. 5. INSTALL ZINC ANODE AND CONNECTIONS PER W-15. ... -~ 0.. 0.. WW w ·O = :: (.0 OJ [ n □ □ □ 1"MIN. □ f7 4" OR 6" DIA. PVC OR ABS PIPE CRUSHED ROCK MIN. 6" DEEP NDS 12" SQUARE POL YOLEFIN GRATE W/ U.V. INHIBITORS. "-r'@ -:=-:r~-~--,u,,--NDS 1 2" SQUARE iw I! t,::! TAPERED ~ ! # 1216 POLYPROPYLENE CATCH BASIN (RISER) W/ U.V. INHIBITORS. I ,- CL L1J 0 ~I~ "' / I ' I~ I NDS 12" SQUARE TAPERED POLYPROPYLENE CATCH BASIN W/ U.V. INHIBITORS. DRILL½'° WEEP HOLE TYPICAL OF 4 PLACES AT BTM CORNERS- CATCH BASIN -LANDSCAPE APPL. D NOTTO SCALE CURB/EDGE RESTRAINT AS PER DETAIL 'A' 2% 5" SUB BASE COURSE l.V,," CLEAN FRACTURED OPEN-GRADED #2 AGGREGATE -- A STEGO 15 MIL VISQUEEN WITH EDGES' LD. OVERLAPPED 4" AND SEALED C?" WATER SERVICE DETAIL G PRIVATE DRIVEWAY SECTION NOTTO SCALE NOTTO SCALE EXISTING ~----'k F. L. EXISTING SLOPE CONC. SWALE NOTTO SCALE 8" 24" F.L. 6X6 -1OX10 W.W.M. TOP OF WALL CONC. SWALE NOTTO SCALE 3 1 /2" BASE COURSE -3/4" WASHED -----FRACTURED OPEN-GRADED STONE #57 AGGREGATE l l/2"BEDDINGCOURSE-l/4"-3/8" -----WASHED FRACTURED OPEN-GRADED STONE #89 AGGREGATE ----4" PERFORATED DRAIN LINE W/ MIN. 2% SLOPE TO DETENTION BASIN AND 3" OF ROCK UNDER LINE AS INDICATED ON SHEET 3 ----PRIVATESEWER LINE VERIFY LOCATION E H -~----------·· REMOVE TOP BLOCK AT GRATE FOR OVERFLOW WALLAS PER PLAN 33" (2)4'/ ABS CATCH BASIN -TOP OF WALL NOTTO SCALE 20"MIN. . 12 i" SQ. WIDTH i 4" -r-----------------------, ,,._,_,,_ ··-·· ··-··--,( I MIN,! cv,---y--,,,--- # 1216 CATCH BASIN -PEDESTRAIN WALK NOT TO SCALE J t-----j----j------------+---+---t---t-----, fSHFil CITY OF CARLSBAD I SHgEETS I ~ ENGINEERING DEPARTMENT GG~R;=;:A~D~IN~G~P;=;LA~N;=s ~Fo:;;R;=: =========1~~x~ "AS BUILT" ~if;< ;,:: ;;,;; exr. cr/50 lzo1J <f/20/1.o1,1 DATE 3-25-2015 ./1. 1 THIS SHEET REPLACES SHEET 5 APPROVED ON 12-12-2014 ADDED SHEET 9 DATE INITIAL REVISION DESCRIPTION INSPECTOR ENGINEER OF WORK DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL LA COSTA VILLAS DETAILS APPROVED: JASON S. GELDERT --~~..,..-i_~~"ll'-"_V ___ 3 ,Z,5,JS cIrY ENGINE R REC 63912 EXPIRES 9/30/16 OWNBY: CHKD BY: ~Jl.~- RVWD BY: PROJECT NO. CT 13-06 DATE DRAWING NO. 483-2A ·. / . ___ _____,,. 01}3015 __/ I / -- 1 O" DRAIN BASIN W/ · SOLID COVER BY NYLOPLAST \ / ) \ I. ~~7 I 10" DIA. ABS PIPE DETENTION BASIN CLEANOUT SCALE; N.T.S. \ I I I I I I I I I I I I I I I I I I I I C2 7 I I 94.33-TW 92 33_-~ I 89.50-BW 8950-B~ L·--;· c.. ~------------------·----·-----·--------·---~-- 6;-:::, IL' --1 r --~No I .. . t~' ·-:-:,. I • \.\ /iii ·1 J_ --ii.I 94.33-ffl ....-----'"'-,,i\ ~, --' -~ G ----. ,if,.,_ ··--. l I 8" A.BS -------=====----I ' 92.33-TVJ I r·"''";:1."' ---· --------7 1---\'6 \-"""--~~-, 'D<o•" I -.;....--• -:S- 7 --- l I .89.50-BW 89.50-BW ' ' es '\'l' D fENSI N I - ( ~~~ti\,_ ___ 8_9~ ~~=~--.J "' I I ii, I I I!. T1 ·-__ _ 1 \10"ABS 92.00-TW 89.50-BW TO CURB OUTLET D-25 8'-0" TO P/L 17'-0" . DETENTION BASIN SCALE: 3/, :' -l '-0" 94.33-TW 94.33-TW 88.00-BW EXISTING 89.50-BW 11\i'lf\[.[~~v;,~ ~-~TE GRADE / WALL TYPE C-3 rn~-~9~1.~66~T~O~G=------t----_-_-_,.,;,';L_~------- WSL100 1 ____ .- _. _ -¥E-Afr-=.:::_ _,. 8" ABS SEE ------------~----89.67 --18 PLAN FOR% -88. HJ FL ;~66 ~L ·~ ~ _ ~L~P_'.: __ ..._, =--~,= f;'mr -fili"~,,~IT:J!.l,(~Ji:~11-Jr-nJ1'1~Tr1 / -j ,, _,, ef ')~ '-l'=ll!c=L Ell[irrJ. ll;;c[J_~!fF.;I ~ ~ffiWm1h1n~ffl -~lllif-~t:··w SECTION SCALE:½~= ·1•~0" r-r--------------,r1.. ______ _ I I ---LL=-==-=-=·==-===---== FRONT ELEVATION SCALE:½"= 1'-0" DETENTION BASIN SECTIONS SCALE:¼" ~ I '-0" 10" DRAIN BASIN W/ SOLID COVER /"~'°-' 86.27 CL ◄llllllilllll---1 \ \ I 10" DIA ABS PIPE TO CURB OUTLET D-25 I 88.12 rL ( .. 1 O" DIA ABS PIPE FROM BASIN B .. D 9 c;;;:,.,::i -\. -"' 9~:;~ 89.50...B I ----------~-8"ABS ------==::::::------------ ,, A DETENTION BASIN SECTION C SCALE:¼" ~ l '-0" 91.66 TOG ------~/ __ B_9_.6_6_F_G ___ ~~·3_•;~~EBOARD --:-~~~u/ l/ ,r---~ ~ _J :t\X 4" DIA. ·:i,; :.~· ~ ½<I~ LI_. :·. PIPE t/.~ . ~ r.•.t··•.·./ ... •.. 88. l O FS 1.··; [·.••.• i~~~~ :iE 1/,. ..•·:·'. ... /. 8 .. 8.l.2F.L .. :''.·,?: RSD-25 -;;;· _L_ "'-. i, L_L ·~-]~~-' INLET -~::,:;~;:.;;A~;:;;;.:.:~:.:;;-~;;,;,.· _D_E_T_E_N_T1_o_N_B_A_s_1N ____ _,1 :a ' ' >-----+---+-----------------+----+---+---+----< I SH?.ET I ~G:::R:::A::D::IN=G~P=LA=N=S=F::O::R=: ==========:::::1.;;.:~_~;(_l)I CITY OF CARLSBAD ENGINEERING DEPARTMENT SHEETS 9 ,, ~UILT" ~Al-..: iii, EXP. q}3n,/z,,2,?, DATE 3-25-2015 J,f.M. )I\ THIS SHEET REPLACES SHEET 7 APPROVED ON " 12-12-2014 ADDED NEW SHEET 9 DATE !NJTIAL REVISION DESCRIPTION INSPECTOR ENGINEER OF WORK DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL LA COSTA VILLAS DETENTION BASIN I\ -A-PP_R_ov_E_□_, Ja,:L;.~~~//~)~'Ji~~-:t.'::1.'.11,u1,,'J,,_ ____ JAS:f,zs':°ls CITY ENGIN.ElaR REC 63912 EXPIRES 9/30/16 DAlE OWN BY: CHKD BY; 4~~/. __ RVWDBY: PROJECT NO. CT 13-06 I DRAWING NO. . 483-2A \ N (2) #5 AT TOP 4'-0" ' \ 3'-6" 7'-0" TO DA YLITE 7'-6" (D-COMPACTED CAP SOIL AS NOTED IN BACKFILL NOTES BELOW #5@ 10" o/c HORIZ. ¾"x 12" GRAVEL \.i:;:;,;tl3++~-~WRAPPED IN FILTER FABRIC REFER TO rnttlf;'----WATERPROOFING #5 (J}-l" ROCK POURED IN PLACE (lc'=2500psi) FOOTING (lc'=2500psi (D-FORMATIONAL SITE WALL -A A SCALE: '½" = l'-0" co 2" #4X36"@ l ~•i O/C I, BENT AS NilED #4 r[~--I ~-- . ,·' 2'-0" 12" 12" 4'-0'' 7'-0" TO DA YLITE 2'-0" MINIMUM COMPACTED CAP SOIL AS NOTED IN BACKFILL NOTES BELOW COMPACTED BACKFILL SOIL AS NOTED IN THE BACKFILL NOTES BELOW FORMATIONAL COMPACTED FILL WHERE OCCURS ON THE PAD PER THE GRADING PLAN SITE WALL -B SCALE: ¾"= 1'-0" 4 #3@ 18" O/C EA. DIR. 5" THICK CONCRETE SIDEWALK 0/ 4" SAND BASE STRUCTURE SLAB ELEVATION AND BUILDING FOUNDATION ,,--EXISTING GRADE ¾"X 12" GRAVEL WRAPF'ED IN FILTER FABRIC ' REFER TO WATERPROOFING NOTES BELOW PLANS FOR WATERPROOFING INFORMATION 4" PERFERATED PVC DRAIN LINE (4) #5 TOP & BOTTOM #5@ 12" O/C KEY REINF. #5 SIDEWALK SHALL BE IN PLACE AFTER THE RETAINING WALL IS BACKFILLED AND THE FOOTING FOR THE BUILDING FOUNDATION IS IN PLACE. BUILDING FOUNDATION FOOTING TO EXTEND INTO COMPACTED OR NATURAL SOIL AS NOTED ON THE FOUNDATION PLAN AND SOILS REPORT B #5 IN ND .------BE~ S _,,,-----(4)#6 #5@ 10" o/c ~~~~~~r-_HORIZ. & VERT. REFER TO WATERPROOFING ll'c'c"#~=-crllil~NOTES BELOW ¾"xl2" GRAVEL WRAPPED IN FILTER FABRIC 2'-3" 7'-0" TO DA YLITE 2'-9" 3'-611 -(D-2'-0" MINIMUM COMPACTED CAP SOIL AS NOTED IN BACKFILL NOTES BELOW (J}-l" ROCK (D-FORMATIONAL SITE WALL -C SCALE: '½" = 1 '-0" ¾"xl2" GRAVEL :::.---WRAPPED IN FILTER FABRIC REFER TO rntt±rr----WATERPROOFING NOTES BELOW BlT:'""...____#6@ 12" o/c VERT. 4" PERFERATED PVC DRAIN LINE (5) #5 TOP & ._.,,,___BOTTOM -------#5@ 14" O/C #5@ 12" O/C (H) POURED IN PLACE (fc'=2500psi) FOOTING (fc'=2500psi C #6 @12'O/C 4'-0" 6'-6" ITE WALL -D1 CALE: ¾"= l'-0" . .. 12" #6@ 12" O/C (V) ( 48" STEEL LAP) _>--j-( 4) #5 3'-6" 2'-6" ~---------~ USE AQUADRAIN BY CETC OVER WOOD LAGGING TO PREVENT UNDER CUTTING UNDER THE UPPER FOOTING (DO NOT UNDER CUT UPPER FOOTING) POURED IN PLACE (lc'=2500psi) FOOTING (lc'=2500psi D1 SITE "BACKFILLED" WALLS SHALL HAVE SELECTED SANDY GRANULAR COMPACTED SOILS WITHIN THE ACTIVE ZONE (1 :1 WEDGE BEHIND THE WALL), AS APPROVED IN THE FIELD BY THE PROJECT GEOTECHNICAL ENGINEER. SANDY SOILS GENERATED FROM THE EXCAVATIONS OF THE SITE FORMATIONAL SANDSTONE BEDROCK (MAPPED AS Td ON THE GEOTECHNICAL MAP BY V&M ENGINEERING REPORT DATED FEB. 20, 1991) SHOULD BE STOCKPILED AND USED FOR THIS PURPOSE, USING SELECT GRADING TECHNIQUES. GOOD QUALITY SANDY GRANULAR D.G. TYPE IMPORT SOILS (100% PASSING l-lNCH SIEVE, MORE THAT 50% PASSING #4 SIEVE AND LESS THAT 18% PASSING #200 SIEVE WITH EXPANSION INDEX LESS THAN 20), MAY ALSO BE NECESSARY FOR BACKFILLED WALLS WITHIN THE ACTIVE ZONE IF CASE OF INADEQUATE QUANTITIES OF ONSITE GENERATED SANDY SOILS AND SHOULD BE ANTICIPATED. WALL BACKFILL MATERIALS AND COMPACTION SHOULD BE CONFIRMED BY THE PROJECT GEOTECHNICAL ENGINEER. SAMPLES OF THE PROPOSED BACKFILL MATERIAL SHOULD BE TESTED BY SMS GEOTECHNICAL SOLUTIONS, INC. IN ORDER TO EVALUATE THE SUITABILITY OF THE SOIL FOR THE PROPOSED USE. RETAINING WALL WATERPROOFING NOTES APPLY A FILTER FABRIC AT THE BOTTOM OF THE FOOTING AND THEN PLACE 2 INCHES OF 1 INCH ROCK OVER THE FABRIC (MIRAFI 140N OR EQUIVALENT) AND A 4 INCH PERFERATED DRAIN LINE ON TOP OF THE ROCK WITH 8 FEET OF 1 INCH ROCK AROUND THE DRAIN PIPE AND WRAP THE FILTER FABRIC AROUND THE ROCK. MIRADRI 860-861 AND CCW 6200 PROTECTION (OR EQUIVALENT) SHALL BE APPLIED OVER THE TOP OF THE FOOTING AND DOWN TO THE BOTTOM OF THE FOOTING. SHEET t-----+---+---------------1-----+--t-----+-----, B:;., .· CITY OF CARLSBAD ENGINEERING DEPARTMENT GRADING PLANS FOR: "AS BUILT" LA COSTA VILLAS ~~ -q/u/2.0~1 PE. ws9 EXP. ~u,o/2.oz.1;; oArE o3-2s-201 s P. 1 REVISED DETAIL 'A' ·2 ,IS ~ RETAINING WALLS DETAILS ' PROJECT NO. CT 13-06 DRAWING NO. 483-2A G430l5 C :e· 00 G) O.i::i,. ..... 00 C.Oc.,., I I\) )> l 12"., ' . . ·. ·• (5) @6 (H) TOP /''.°i:, , ' SITE WALL 'A' SEE DETAILA/8~ • • • • • ::'III- M11~ 11--11 . ITII ITT; &:. • · i n~~n • S -----m.~~ ,cl It: u 3; ~ _, F d111111m11 ~ ~ ( ) # @ " / v :y • ' -I<{ ~ -I--IIIr=T FIRST 36" / ' ' · _,_. __ ,_, __ ,_. --j--'Ll• • • ol!::1 2 5 12 oc .· co,--cc= 1,==1. ~. , .icuuo.: F =111- WALLA/8 I", ''-. SIMF!.\ON EPOXY 8,, 58,, (ESR 250S) ,,.,..,·•1<:--------''1'. ,, ' ' ... WI SPECIAC'•., r (4) #6 X58" INSPECTIO~··"' (LAP W/ 4, 6 HORIZ.} ,i._TOW -s;·; IT n..z ~ ( H) ~•. ' V1 'i -.... -.... ~ v, ,_J.11--11 -· •· · #6@ 9" 01c 1vi LU "' ~ o V1 z ~ In1-- @ g§ #5 @ 16" O/C (V) 1• ··, INSIDE FACE ~~ •-----/1+#''1'!:f~--i-~ }'::I II--:;lTf"'"I IT:.. -fTI';"'! c::Tff;';'fTE':ITf= g§ 2 OUTSIDE FACE ' . rlit,--~L~A~P~BA~R=s~48="-MIN. > ' ,·1 . ·~ ~lJJ---ill-r,=illn;l~-n=lJ.l;:-~=T·rIHrr-lL.'--11 ,rl ~~ #5@12"0/C /v r·f ~ ~~~ ·· .. / <'; #6@16"0/C EXISTl~-~l;~~~;'N'G~L~:~~:l;LJ1::1::;~~~:: ~:cLO~~~~T/~SHrR ~5>-(H)-----<~ {·.' 'i'cc--.. (V) FORWALLA/8 rf-TIT=-nf'1nrff'rn , -o·' z !;z ' ""-' · •r i'l U@ I ,'. . --1••·--111-1•1-11 . o o -. I . ._:::JD[--,. • . JC]r=:Jr:]r_::rt . ~ i 2) # 6 'l-'_lnr rn ' m-/ 2 U ~ ,;, I.•·· , ~ WOOD LAGGING WITH "° . ' ,. •· :,. · ·. '['. ;,'"':. , . (4) #5 (T&B) =I Iii I IJ~ll~l I II I lu #5@12"0/C-1··,,· WATERPROOFING -.,.___,_ ........ ·; · •• _•. . 34" 6" .... .. , ......... ~--:::E~~-;;;.-... . • I ... ,. . (2) #5X40" -------•. , . @l 4" 0/,_'.:C:...__.:::::=====::::t"" .. ~ '·.' WALL 01/8 , .. ,,.. WALL D l/8 7;;---.-:,; --,,-,,,-----1· , 34" , 6':: ' r , BUILDING CAST IN PLAN WALL (UNDER BUILDING PERMIT) SIMPSON SET EPOXY .,--------~,_· ~--,(ESR 2508) TYP. . "'.,. I , '.J (2) #5X40" @14" 0/C .. _-. . -----t,s· ,. •·1 ,.,__--._____ #5@ 14" 0/C 'l•.J· --t---=-#5 . ----' . .JI ·~ .,, . -1 I 1--1 I I-IJ " · , WALL (UNDER BUILDING ,' =III ·,·:,1:r.·,.:., .. ,~ #6 @ 9"o/cVERT. . IIILcc:111= • PERMIT) ~ ,. t_"_~1111i1IT'1;1·1'\_·,.,1~:_.·1,·1l·F· •• ;1.i,·_J.'_·_./_·"'1·•1l_:_'"_.m·._l·l~--···~-.t-i1"·1_1i~l·l·I•.·'· -INSID-~-::-~-~-UA-0-RA_I_N_B_Y_C_E-TC_O_V_E~R • , l'-10" :2" 'l'-6" USE AQUADRAIN BY CETC OVER ' ~ill~ ~Ujij ____ ---,--#5X40" @l 2" 0/C ~~~~~~~~~~:-:=.""'·· ~.:-ci;---s(EIMSRP2S500N8)STEYTPE.PWO/XY ' ' I I I I JI IEI 11 '110 :sLn--I 11 In WOOD LAGGING TO PREVENT ''-;-__ 4_, __ 4,_, ---'I,. WOOD LAGGING TO PREVENT " 'ffillJI I 1:= , :111 " UNDER CUTTING UNDER THE ~ mWm~ ; UPPER FOOTING (DO NOT UNDER CUT UPPER FOOTING} ,. 1iTI'Jlhil JH1JlITTill l-cffic-III III-·:ffi :111=111=111=111= l~~f1r Llmµ\r 111~11 3•_9" ~gg~1~6~1~.~~;io;~i=2soopsil , 5'--0':·-• ';J.,i,, :»-• J 2'-0" , POURED IN PLACE (fc'=2500psi) _/ .. .I .,"',--_l_'-_O'_' _____ ''---"I.' FOOTING (fc'=2500psi _ ~'fL~~~/S •· ·. ~~=-.,..,-~·---=--=-------_...___~~""'.""""'.""""'.""""'.""""'.""""'.""""'.""""'.""""'.""~~,::~·t::-:=-:--=--:--:--:-:---:::-=------------------+· .. • __ 't--,----::---::-c..,.--c=--=-=:,---c--:-:-,.,--::,----::-:-,-,c-:--:--:--,--:-:---------!::·-;.:.·,,-1.....,--<-:---:::-::-----::--::-----::-----::-----------',,-o·.,_'' SITE WALL -D2 ,. "02 : SITE WALL -D3 ,, "03 -D4 CONNECTION TO SITE WALL A/8 ,.. D4 -SITE CONNECTION TO BUILDING WALL SCALE: ¾" -]' rJ' y D5 : >-._ , SCALE: ¾" -1' rJ' >-, CALE: ¾" -1 '-0" >-, ' SCALE: ¾" -I '-0" -~ ' \ \ lo. ~ "AS BUILT" _tjia--------------. e.e. 'Af'/5'9 exP. q/.wl z.o-z.!, r , ~ ,,INSPECTOR I ., SITE "BACKFILLED" WALLS SHALL HAVE SELECTED SANDY GRANULAR COMPACTED SOILS WITHIN THE ACTIVE ZONE (1 :1 WEDGE BEHIND THE WALL), AS APPROVED IN THE FIELD BY THE PROJECT GEOTECHNICAL ENGINEER. SANDY SOILS GENERATED FROM THE EXCAVATIONS OF THE SITE FORMATIONAL SANDSTONE BEDROCK (MAPPED AS Td ON THE GEOTECHNICAL MAP BY V&M ENGINEERING REPORT DATED FEB. 20, 1991) SHOULD BE STOClr.:PILED AND USED FOR THIS PURPOSE, USING SELECT GRADING TECHNIQUES. GOOD QUALITY SANDY GRANULAR D.G. TYPE IMPORT SOILS (100% PASSING l-lNCH SIEVE, MORE THAT 50% PASSING #4 SIEVE AND LESS THAT 18% PASSING #200 SIEVE WITH EXPANSION INDEX LESS THAN 20), MAY ALSO BE NECESSARY FOR BACKFILLED WALLS WITHIN THE ACTIVE ZONE IF CASE OF INADEQUATE QUANTITIES OF ONSITE GENERATED SANDY SOILS AND SHOULD BE ANTICIPATED. WALL BACKFILL MATERIALS AND COMPACTION SHOULD BE CONFIRMED BY THE PROJECT GEOTECHNICAL ENGINEER. SAMPLES OF THE PROPOSED BACKFILL MATERIAL SHOULD BE TESTED BY SMS GEOTECHNICAL SOLUTIONS, INC. IN ORDER TO EVALUATE THE SUITABILITY OF THE SOIL FOR THE PROPOSED USE. RETAINING WALL WATERPROOFING NOTES APPLY A FILTER FABRIC AT THE BOTTOM OF THE FOOTING AND THEN PLACE 2 INCHES OF 1 INCH ROCK OVER THE FABRIC (MIRAFI 140N OR EQUIVALENT) AND A 4 INCH PERFERATED DRAIN LINE ON TOP OF THE ROCK WITH 8 FEET OF l INCH ROCK AROUND THE DRAIN PIPE AND WRAP THE FILTER FABRIC AROUND THE ROCK. \ \ ' , MIRADRI 860-861 AND CCW 6200 PROTECTION (OR EQUIVALENT) SHALL BE APPLIED OVER THE TOP OF THE FOOTING AND DOWN TO THE BOTTOM OF THE FOOTING. ' ' f--~-+--+---------~--~-f------f---1---+----"--I I SHEgET I CITY OF CARLSBAD ~: ENGINEERING DEPARTMENT ~- ~G:';;R~AD;:;IN:;;G~P~lA~N:;;S",:f;:c;OR;;_':========~:rj~~ LA COSTA VILLAS RETAINING WALLS DETAILS "J/u/2~z.11----+----+----------------1----1----+---+---j ~=====;,t==f',,·-~=.==;========~ APPROVED:// ') ( I 1--1-,f-' JASON s. GELDER! DATE --~L,;Llj~~><.<'.'.'1....,Ll.1<'!!.£.' ',l,'.:.JI/ILL------3 · 2 f, IS CITY ENGlWfER REC 63912 EXPIRES 9/30/16 ADDED NEW SHEET 9 :=====::::;-;::::=======;-;:,=-=-=-=-=-=-=~ l---=0A"°'TE=-1--::-,N:;o;c1T"'IAL-t-;,a,,C?t--1-------------t---=-□Ac=T=-E -+--,"'N1r=-1Ac--L-+-co,-,.A=TE--+-,-,N=1T,--1AL---, OWN BY: il"..f' I PROJECT NO. I DRAWING No. ./ REVISION DESCRIPTION CHKD BY: '.Pr·· CT 13·06 483-2A ENGINEER OF WORK OTHER APPROVAL CITY APPROVAL LR_vw_o_B_Y: -=== ~------~ 03-25-2015 fJ. e. /1\ ADD NEW RETAINING WALL DETAIL D2 · D5 Cf /ie/yz,( ( □ATE DAlE / ---------