HomeMy WebLinkAboutDWG 359-1L; SDP 90-05; PRICE CLUB; 01-02REPAIR OR REPLACE <D
~
EXISTING LANDSCAPE-,. ~======::=======================================================================1
I HEREBY DECLARE THAT I AM THE LICENSED
DESIGNER OF LANDSCAPE WORK FOR THIS
PROJECT, THAT I HAVE EXERCISED RESPONSIBLE
CHARGE OVER THE DESIGN OF THE PROJECT AS
DEFINED IN SECTION 6703 OF THE BUSINESS AND
PROFESSIONS CODE, AND THAT THE DESIGN IS
CONSISTENT WITH CURRENT STANDARDS.
.. ___.., ...... SHRUI
/
(3) 2dxl' MIN.
LOOOE'POLE l"INt
STAKES DRIVE:N
OUTSIDE OF
ROOTBALL INTO
5UBQRAIJE
0
" I
PRESERVE EXIST.
(CUP. ANA.)
---
REMOVE EXISTING /
OLEANDERS REPLACE EACH I w/ (1) LIG. TEX. (s) GAL.~ j
REMOVED TREE
TYP. --,
\ ········•·,
--......__. -----------
J
' <.•.\ )~'
' J•//r
/ / . 1 './ .• I
~ __ 7L.5_ •.. 1· .. •Ji ___ ,,,.}
,' / ----
j
j
j
in .
j
B.7%
f----
N r--
D@]
I I
1 % I I
<i------:,L _____________ ..J
in .
N
"
PRESERVE EXISTING
LANDSCAPE --\
I
/
-EXIST A A
LIGHT/
/
/
', , /PRE ERVE EXI
·-LcUP. ANA.
I --I
I
I
I
I
TING \L~2) HEM. FUL.
5 GAL.
1.) SAVE AND PROTECT ALL EXISTING PLANT MATERIAL DESIGNATED TO REMAIN UNDISTURBED
REPAIR ANY DAMAGE TO EXISTING AREAS CAUSED BY IRRIGATION TRENCHING, WIRING
2.)
3.)
4.)
5.)
OR ROUTING TO PROVIDE A COMPLETELY FINISHED PROJECT WITH GROUND COVER INTACT
IN ALL AREAS, REMULCHED TO NEW. REPLACE ALL DAMAGED LANDSCAPE WORK.
ALL NEW PLANT MATERIAL SHALL BE IN ACCORDANCE WITH THE SIZES AND TYPES
SPECIFIED IN THE LEGEND AND SHALL MATCH THE EXISTING PLANTING. EXISTING TREES
AND SHRUBS TO BE REMOVED MAY BE RELOCATED TO THEIR FINAL LOCATION IF PERMITTED
BY THE OWNER AND CITY: SAME GUARANTEE APPLIES AS IF NEW.
FEATHER THE TRANSITION BETWEEN NEW GRADES AND EXISTING GRADES TO PROVIDE A
SMOOTH, CLEAN, EVEN TRANSITION.
THE EXIST. AUTOMATIC IRRIGATION SYSTEM WILL BE EXTENDED INTO ALL NEW LANDSCAPE
AREAS, SEE SHEET 2 OF 2.
SOIL IN PLANTERS:
ALL NEW PLANTER AREAS ARE CONVERTED FROM AREAS WHICH HAVE BEEN COVERED WITH
AC PAVING. IN LIEU OF TESTING IN SITU SOILS FOR RESIDUAL HERBICIDE AND SUITABILITY
FOR PLANT GROWTH, REMOVE 12" OF SOIL SUBBASE UNDER NEW PLANTERS AND EXPORT
OR USE THIS EXCAVATED SOIL FOR ENGINEERED FILL UNDER NEW PAVEMENT.
FOR SOIL IN PLANTERS AND FOR BACKFILL UNDER AND AROUND TREES AND SHRUBS,
USE AN IMPORTED AMENDED "TOPSOIL" MIX CERTIFIED TO BE FREE OF HERBICIDE, OTHER
DELETERIOUS CHEMICALS, ROCK AND DEBRIS. EACH CUBIC YARD OF THIS "GROW MIX"
SHALL CONTAIN 1 /3 CY OF NITRIFIED REDWOOD SHAVINGS, 15 LBS. OF (5-3-1)
GRO-POWER (SO. CAL. FERTILIZER CO.), 30 LBS. OF GYPSUM, AND 2.5 LBS OF SOIL
SULFER.
in
N
"
\
\
-----
\
-
REPAIR OR REPLACE
EXIST. LANDSCAPE
WORK AT NEW TANK
VENTS AS REQ.-/
----
in
\
#,,L//' •. / \
/
0
--/ ' I \
0 0
--
I UNDERSTAND THAT THE CHECK OF PROJECT
DRAWINGS AND SPECIFICATIONS BY THE CITY OF
CARLSBAD IS CONFINED TO REVIEW ONLY AND
DOES NOT RELIEVE ME, AS THE LICENSED
DESIGNER OF WORK, OF MY RESPONSIBILITIES FOR
PROJECT DESIGN.
THESE PLANS HAVE BEEN PREPARED IN
SUBSTANTIAL CONFORMANCE WITH THE APPROVED
LANDSCAPE CONCEPT PLAN, WATER CONSERVATION
PLAN, FIRE PROTECTION PLAN, AND ALL
CONDITIONS OF APPROVAL RELATED TO
LANDSCAPING.
BY: ~ ff?2,.,,,,.._,q,...__,C=4'-'-T"--'/.:1~--
DATE: _ __,,11., OCT. 97 L.&
/
1/:r• BlJ.CK
/ ~UBBEM Hon ovu I 12 GA_ GAL'v. WIR(
'l,,. -···-·-.. ·-1!----41';:-11 /~ 3"-DEE:P WAii::RINCi
\\ __ / 8,1,.SIN
~~3" MULCH
PU.NT TAIILETS / · , __ . __ :~--
PER M.fGR. _j I 1··------._ AMENDED
RECOW, j... .... --~---··-.. .. EIACKrlll MIX.
A.•l.5 TIMES CDNTltlNEII HEIGHt • ... rwo TIMES CONTAINER HEIGHT
',_
Ui 2,~.2. cn:P ROOt ·' ·, ·, ..;_[ffi.! '-
BARRIER E:XTENO ~• ~~ \._ F'INl5H GIH.D! ~ ---PAST TRUNK IN IJOTH +---+1 e~'---'"-11"-., , --...._ ___ F'l.,ANTINQ MIX
DIRECTIONS. TOP IS 2• ~ ' ~ -, rs;, fill IEl.OW T.C. AND ~IN. 1't _j ·-, •.. ....__ BR'~r~ UP
AEIO'v'E. GRAOf::. SIDES AND
C:ONiAl"'1tR 01.4. BOTTOIII . OF PIT
SHRUB PLANTING 'TJ!..EE PLANT1NG _________ --+-r:u~i=='
MC)Wllli'/lf..ANITAAS ~
PLANTING AREA TABULATION
I
LRELOCATED
LIGHT
809 SF
1149 SF
+340 SF
EXISTING
1-5
,.UOMAR MR~ RDA
C,t,111.SBADm
C051CO f
LslTE LOCATION
• --REPLACE DAMAGED AND REMOVED PLANTING
AT NEW ELECTRICAL WORK AS REQ. -EXISTING
ELECTRICAL
VAULT
-
0 . -
-. (1)/CUP. ANA.
1 PRESERVE EXIST.
/ CUP. ANA.
I I
---. /24" BOX
-. -. -~ -_ 71 / . 71
---; -rs1ht8A1=, IND, .. ----
I I I i~. ~---.....~c.---
/' ' '•
\
-I \ --I ---1
F I ;-=ffil--
-
VICINITY MAP (NOT TO SCALE)
PLANT LEGEND (FROM EXISTING ON SITE) NEW MATERIAL SHOWN HEA.VIER LINE
COUNT OF NEW
+(3)
-(1)
NET +(2)
NUMBER OF
SYMBOL
•
BOTANICAL NAME
STREET TREES
TRISTANIA CONFERTA
(TRI. CON.)
COMMON NAME
BRISBANE BOX
CARROTWOOD
SIZE
24" BOX
USE ROOT
BARRIER
24" BOX
5 GAL.
NOT INCLUDE REPLACEMENT OF DAMAGED OR DESTROYED PLANT MATERIAL
NEW TREES IS EQUAL TO OR GREATER THAN TREES WHICH MUST BE
a,
<D
in
,-._
in 0 co '-'
<(
<(
w u z w
[L
. w
l,n w
-' Cl::
<( ::r: u
,-. "' O> :z '0 ,-. 1--
$ ~
"' 0 u
"' "' ~ tl L,J ::c :::I u L,J
"' :z ::, :5 0 D. L,J
"' ~ ~
L,J u
i:; -' "' ~ Lu >-,< 1--Lu u u
ffiNOTE:COUNTS DO
______________ REMOVED. --------------------,,...------------------1
£
THE SOURCE AND SPECIFICATIONS OF THE AMENDED TOPSOIL PLANTING MIX SHALL BE
APPROVED BY THE CITY INSPECTOR PRIOR TO IMPORTING THIS MATERIAL. A SOIL TEST IS
REQUIRED.
ESTIMATED QUANITY: 1149 SF x 2' + 27 = 85 CY TOPSOIL/ PLANTER MIX
6.) PROVIDE "DEEP ROOT" BARRIERS FOR ALL NEW TREES WHICH WITHIN 6' OF CURBS. USE
7.)
13.)
[ill
2' DEEP UB 24.2 x10' LONG BARRIERS CENTERED ON TRUNK TREE.
PROVIDE 3" THICK LAYER OF WOOD CHIP MULCH IN ALL EXISTING AND NEW PLANTERS
WITHIN THE WORK AREA. SUBMIT MULCH SAMPLE TO CITY INSPECTOR FOR APPROVAL.
EXACT LOCATION OF ALL TREES SHALL BE SHOWN ON PLAN.
REMOVE EXIST. CURB CAREFULLY TO PRESERVE EXISTING PLANTING AND IRRIGATION WORK
AS MUCH AS POSSIBLE. ALL EXISTING SHRUBS AND TREES DAMAGED BY CONSTRUCTION
SHALL BE REPLACED W/ NEW 5 GAL. SHRUBS AND 24" BOX TREES.
[ill CONSTRUCT NEW CURB AND CONCRETE WALK TO AVOID DAMAGE TO EXISTING LANDSCAPE.
LANDSCAPE SHEET INDEX: APPROVED FOR PLANTING "AS BUIL T11
395-1L10F2PLANT1NGPLAN &socr.97 AND IRRIGATION ONLY,
395• (abF tGATIONPLAN &socT97 INCLUDING PRECISE
LOCATION OF PLANTING
AREAS.
E~.. ff:R'S SIG• N. TURf. RcQUIRED ON PAG~1 0 LY ::Y~ ..... W~·~---
ENGINEERING PLANCHECKER D TE
TITLE ______ _
REVIE'w'ED BY1
INSPECTOR
I SH1EET I CITY OF CARLSBAD
1-----1----,1----------------+----+--t----t------i PLANNING DEPARTMENT
DA TE INITIAL
F.NGINEER OF WORK
------------------1---t---t----r-----i
REVISION DESCRIPTION
DATE INITIAL DATE INITIAL ·---+--~--1
OTHER APPROVAL CITY APPROVAL
COSTCO WHOLESALE
GASOLINE STATION
PLANTING PLAN
DATE
DATE
/~
I I I
EXISTING HEAD _/
REDIRECT NEW EMITTER
LINES TO SERVE NEW
AREA AS WELL
D1 C -8 GPM
I
1¾ I I
-
EXIST. 1" SLV.
1/2" LATERAL
IRRIGATION NOTES
/;II .• ill
j
U")
r--
70.5
8.7%
~
N r--
~ ~ ' L _____________ _j
U")
SLEEVE TO
PASS UNDER
HOLDING TANK
1. MAINTAIN ALL EXISTING PLANTS WHICH ARE TO REMAIN. PROVIDE REGULAR AND SUFFICIENT
WATER UNTIL THE REVISED SYSTEM IS WORKING AND NEW PLANT MATERIAL IS ESTABLISHED.
2. (7) NEW HEADS ARE SHOWN, (?)EXISTING HEADS ARE SHOWN TO BE REMOVED. THERE SHOULD
BE NO NET CHANGE IN GPM THRU VALVE D1C.
SERVICE EXIST FILTER [] AT EXIST. REMOTE CONTROL VALVE. r;/') 3.
4. WHERE LATERALS RUN BELOW PAVING, RUN IN SCHED. 80 PVC SLEEVE. SLEEVES TO BE 2x SIZE
OF IRRIGATION PIPE, BURY MIN. 30".
5. NO NEW CONTROLLERS, ZONES, OR OR BACKFLOW DEVICES ARE REQUIRED.
6. MATCH EXISTING EQUIPMENT AND DETAILS IN ALL RESPECT EXCEPT EXCHANGE EXISTING LIDS-USE
NEW PURPLE COLOR LIDS.
7. PROVIDE (4) EMITTER LINES FOR EACH TREE.
AT ALL OLSON EM-12 EMITTER HEADS, DISCARD EXIST. TUBING AND REPLACE WITH NEW TUBING.
S. FLUSH AND CHECK EACH TUBE TO ASSURE IT IS OPERATIONAL AND INSTALL CAP.
--\ ---....__ ---....__ ----i-.'-..L :,
r---RELOCATE IRRIGATION IF AND
AS REQ. AT TANK VENTS
-
---.
-
--.
....__ ---7 4 -....__ ----
,---EXIST. PRESSURE LINE
TO QUICK RELEASE COUPLERS
7
ll"
<
IO
0
l'-
1 m
\0
I()
,-..
I()
0
IX) ..._,,
<C(
<
w u z w n. . w
VI
L,J
-' a,: < ::c u
iffl: ~
\ s";:/H~\~l~:Jj/1--1\\:~J~~::------EXTEND EMITTER \--RELOCATE EXIST.
' . .. -
\ '· •,, ' ,
,, )(,'·'.': · .. ' ;;
' ' ,ii_-,._,,, .. · ,:
1--------+~---------L--'_-___ ,, ___ '_-___ ,, ___ ' __ ,,~ (f,1 ... 4 ---__ 72_.5 ----------. TUBES TO ALL \ AREA LIGHT
--._AREAS, TYP.\ >\: .
·,:
:. COORDINATE WITH NEW ELECTRIC ....____ .....___ '---.. "-.._ \R (!/ ~\t// //)'>'')r>
/ AND PHONE SERVICES WHERE '-,_ \ [ /. J/ / _/ .. \; . R
/ THEY ARE PROPOSED TO RUN PARALLEL. RELOCATED \_!/ ·. ";' <:,</ /"/y ---------
\
--..... I ........ 1 1" sLv. uGHT------.__\ _ / ,;:;:: "/ M../,,--cAP ExIsT.
------='----=--·
CJ> ' 00 ' 0
----
---
-
IRRIGATION PLAN
1" = 1(] 0
IRRIGATION LEGEND
EXIST. RAINBIRD PEB SERIES REMOTE CONTROL VALVE
EXIST. RAINBIRD RBY-100-200 "Y'-FILTER W/200 MESH
SCREN FOR DRIP SYSTEMS IN SEPARATE VLAVE BOX
X EXIST. HAMMOND HV-8401 BALL VALVE -LINE SIZE
• OLSON #EH-12 EMITTER HEAD W/(12) 16 PH OUTLETS
C) EXIST. OLSON #EH-12 EMITTER HEAD
~--R DENOTES HEAD TO BE REMOVED (7)
DENOTES HEAD TO BE MOVED
RAINBIRD 44 NP QUICK COUPLING VALVE (EXIST.)
TREE, SEE L-2, N DENOTES "NEW" TREE -ALLOW
FOR TREE WELLS
NEW Cl 200 PVC PIPE (PURPLE COLOR) W/ SCHED. 40
FITTINGS, MIN. 12" COVER.
DENOTES NEW PLANTER TO BE SERVED BY EXTENSION
OF EXISTING IRRIGATION SYSTEMS.
5
\_ EXIST AREA
LIGHT
70 -~
OLSON BUG CAP
#i302 · \
71 .5 V /
NEW METER I 1/
PEDESTAL _/ /
ELECTRICAL
VAULT
-{
E~ITfE~ ACCESS
~---aox W/LID(PURPLE)
/EMITTER HEAD
~~ SCH, ;o PVC
f'ITTING
1/2'" RADIUS, TY,a,, ,. .... \ ~
~ r 1 /2"PR£M0LDED JOINT MATERIAL
FORMED AND SACKED f• "s-'CO-'-'NT-'--. -__c"'·~-~'--1--t---"r< •• CONC. AT
ARCHITECTURAi,. ~Tl / ISLAND SLAII, CONCRETE SURFACE • AC PAVll-'C
Pl'LACE J/~" C.RAVE:L AS ·-...... ro ELSEWHERE
INOICAfEO CONTIMUOUS :r: ,., ..., ? _ 7 ? ?
ALONG WALL/FOOTING I . .
INTERrACE (6"•1").
SURROUND WITH 4 oz GEOTEXTILE ......... __ .
1 ■ IJVC Sl,.[~VE AT
1 O' oe FOR WEEIJ HOLES
24'" OF PL.ANTER I W "'H+4•
l.11]( SOILS _/ 1, ____ ·---------,
FIRM ORIGINAL/ FOR 'H' < 18", USE DETAIL@
S01L 0~ ENGINEE:RE:D c-2
rill. CO~PACTtD TO
9~" H=1B■ TO 2,•, W::.:28"
H=24" TO .'50 .. , W=.'5'" (~._)(, H::::30")
10 20 30 40 ------~,----DRIP EMITTER HEAD DETAIL
NrS
CURB/ WALL DETAIL WHERE 'H' EXCEEDS 1El'{MAX. 30')
NrS
GRAPHIC SCALE
USE NEW PURPLE
COVERS, TYP.
12 GPH AT 30 PSI
.2 GPM
(40) HEADS= 8 GPM
ENGINEER'S SIGNATURE REQUIRED ON PAGE 1 ONLY
APPROVED
F.NGINEERING PLANCHECKER DATE
APPROVED FOR PLANTING
AND IRRIGATION ONLY,
INCLUDING PRECISE
LOCATION OF PLANTING
AREAS.
"AS BUILT"
TITLE---~---
REVIEl,'ED BY,
INSPECTOR
COSTCO WHOLESALE
GASOLINE STATION
IR ATION PLAN
APPROVED
ASSISTANT
~
..... "' "' z ' 0 ,..._
I-"' u ' w IJJ "' "' 0 u
"' " I-u z w w :c :::I u w "' z 3 :s 0 w a..
"' ~ ~
w u > _J LoJ .. "' "' L,J >-z I-L,J u "'
DATE
DATE
DATE INITIAL DATE INITIAL DATE INITIAL
DWN BY: __ _ PRO ECT NO. DRAWING ND.
ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL
CHKD BY: __
RVl,'D BYc SOP 90-05(c) 359-1 L