Loading...
HomeMy WebLinkAboutDWG 359-1L; SDP 90-05; PRICE CLUB; 01-02REPAIR OR REPLACE <D ~ EXISTING LANDSCAPE-,. ~======::=======================================================================1 I HEREBY DECLARE THAT I AM THE LICENSED DESIGNER OF LANDSCAPE WORK FOR THIS PROJECT, THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. .. ___.., ...... SHRUI / (3) 2dxl' MIN. LOOOE'POLE l"INt STAKES DRIVE:N OUTSIDE OF ROOTBALL INTO 5UBQRAIJE 0 " I PRESERVE EXIST. (CUP. ANA.) --- REMOVE EXISTING / OLEANDERS REPLACE EACH I w/ (1) LIG. TEX. (s) GAL.~ j REMOVED TREE TYP. --, \ ········•·, --......__. ----------- J ' <.•.\ )~' ' J•//r / / . 1 './ .• I ~ __ 7L.5_ •.. 1· .. •Ji ___ ,,,.} ,' / ---- j j j in . j B.7% f---- N r-- D@] I I 1 % I I <i------:,L _____________ ..J in . N " PRESERVE EXISTING LANDSCAPE --\ I / -EXIST A A LIGHT/ / / ', , /PRE ERVE EXI ·-LcUP. ANA. I --I I I I I TING \L~2) HEM. FUL. 5 GAL. 1.) SAVE AND PROTECT ALL EXISTING PLANT MATERIAL DESIGNATED TO REMAIN UNDISTURBED REPAIR ANY DAMAGE TO EXISTING AREAS CAUSED BY IRRIGATION TRENCHING, WIRING 2.) 3.) 4.) 5.) OR ROUTING TO PROVIDE A COMPLETELY FINISHED PROJECT WITH GROUND COVER INTACT IN ALL AREAS, REMULCHED TO NEW. REPLACE ALL DAMAGED LANDSCAPE WORK. ALL NEW PLANT MATERIAL SHALL BE IN ACCORDANCE WITH THE SIZES AND TYPES SPECIFIED IN THE LEGEND AND SHALL MATCH THE EXISTING PLANTING. EXISTING TREES AND SHRUBS TO BE REMOVED MAY BE RELOCATED TO THEIR FINAL LOCATION IF PERMITTED BY THE OWNER AND CITY: SAME GUARANTEE APPLIES AS IF NEW. FEATHER THE TRANSITION BETWEEN NEW GRADES AND EXISTING GRADES TO PROVIDE A SMOOTH, CLEAN, EVEN TRANSITION. THE EXIST. AUTOMATIC IRRIGATION SYSTEM WILL BE EXTENDED INTO ALL NEW LANDSCAPE AREAS, SEE SHEET 2 OF 2. SOIL IN PLANTERS: ALL NEW PLANTER AREAS ARE CONVERTED FROM AREAS WHICH HAVE BEEN COVERED WITH AC PAVING. IN LIEU OF TESTING IN SITU SOILS FOR RESIDUAL HERBICIDE AND SUITABILITY FOR PLANT GROWTH, REMOVE 12" OF SOIL SUBBASE UNDER NEW PLANTERS AND EXPORT OR USE THIS EXCAVATED SOIL FOR ENGINEERED FILL UNDER NEW PAVEMENT. FOR SOIL IN PLANTERS AND FOR BACKFILL UNDER AND AROUND TREES AND SHRUBS, USE AN IMPORTED AMENDED "TOPSOIL" MIX CERTIFIED TO BE FREE OF HERBICIDE, OTHER DELETERIOUS CHEMICALS, ROCK AND DEBRIS. EACH CUBIC YARD OF THIS "GROW MIX" SHALL CONTAIN 1 /3 CY OF NITRIFIED REDWOOD SHAVINGS, 15 LBS. OF (5-3-1) GRO-POWER (SO. CAL. FERTILIZER CO.), 30 LBS. OF GYPSUM, AND 2.5 LBS OF SOIL SULFER. in N " \ \ ----- \ - REPAIR OR REPLACE EXIST. LANDSCAPE WORK AT NEW TANK VENTS AS REQ.-/ ---- in \ #,,L//' •. / \ / 0 --/ ' I \ 0 0 -- I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BY THE CITY OF CARLSBAD IS CONFINED TO REVIEW ONLY AND DOES NOT RELIEVE ME, AS THE LICENSED DESIGNER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. THESE PLANS HAVE BEEN PREPARED IN SUBSTANTIAL CONFORMANCE WITH THE APPROVED LANDSCAPE CONCEPT PLAN, WATER CONSERVATION PLAN, FIRE PROTECTION PLAN, AND ALL CONDITIONS OF APPROVAL RELATED TO LANDSCAPING. BY: ~ ff?2,.,,,,.._,q,...__,C=4'-'-T"--'/.:1~-- DATE: _ __,,11., OCT. 97 L.& / 1/:r• BlJ.CK / ~UBBEM Hon ovu I 12 GA_ GAL'v. WIR( 'l,,. -···-·-.. ·-1!----41';:-11 /~ 3"-DEE:P WAii::RINCi \\ __ / 8,1,.SIN ~~3" MULCH PU.NT TAIILETS / · , __ . __ :~-- PER M.fGR. _j I 1··------._ AMENDED RECOW, j... .... --~---··-.. .. EIACKrlll MIX. A.•l.5 TIMES CDNTltlNEII HEIGHt • ... rwo TIMES CONTAINER HEIGHT ',_ Ui 2,~.2. cn:P ROOt ·' ·, ·, ..;_[ffi.! '- BARRIER E:XTENO ~• ~~ \._ F'INl5H GIH.D! ~ ---PAST TRUNK IN IJOTH +---+1 e~'---'"-11"-., , --...._ ___ F'l.,ANTINQ MIX DIRECTIONS. TOP IS 2• ~ ' ~ -, rs;, fill IEl.OW T.C. AND ~IN. 1't _j ·-, •.. ....__ BR'~r~ UP AEIO'v'E. GRAOf::. SIDES AND C:ONiAl"'1tR 01.4. BOTTOIII . OF PIT SHRUB PLANTING 'TJ!..EE PLANT1NG _________ --+-r:u~i==' MC)Wllli'/lf..ANITAAS ~ PLANTING AREA TABULATION I LRELOCATED LIGHT 809 SF 1149 SF +340 SF EXISTING 1-5 ,.UOMAR MR~ RDA C,t,111.SBADm C051CO f LslTE LOCATION • --REPLACE DAMAGED AND REMOVED PLANTING AT NEW ELECTRICAL WORK AS REQ. -EXISTING ELECTRICAL VAULT - 0 . - -. (1)/CUP. ANA. 1 PRESERVE EXIST. / CUP. ANA. I I ---. /24" BOX -. -. -~ -_ 71 / . 71 ---; -rs1ht8A1=, IND, .. ---- I I I i~. ~---.....~c.--- /' ' '• \ -I \ --I ---1 F I ;-=ffil-- - VICINITY MAP (NOT TO SCALE) PLANT LEGEND (FROM EXISTING ON SITE) NEW MATERIAL SHOWN HEA.VIER LINE COUNT OF NEW +(3) -(1) NET +(2) NUMBER OF SYMBOL • BOTANICAL NAME STREET TREES TRISTANIA CONFERTA (TRI. CON.) COMMON NAME BRISBANE BOX CARROTWOOD SIZE 24" BOX USE ROOT BARRIER 24" BOX 5 GAL. NOT INCLUDE REPLACEMENT OF DAMAGED OR DESTROYED PLANT MATERIAL NEW TREES IS EQUAL TO OR GREATER THAN TREES WHICH MUST BE a, <D in ,-._ in 0 co '-' <( <( w u z w [L . w l,n w -' Cl:: <( ::r: u ,-. "' O> :z '0 ,-. 1-- $ ~ "' 0 u "' "' ~ tl L,J ::c :::I u L,J "' :z ::, :5 0 D. L,J "' ~ ~ L,J u i:; -' "' ~ Lu >-,< 1--Lu u u ffiNOTE:COUNTS DO ______________ REMOVED. --------------------,,...------------------1 £ THE SOURCE AND SPECIFICATIONS OF THE AMENDED TOPSOIL PLANTING MIX SHALL BE APPROVED BY THE CITY INSPECTOR PRIOR TO IMPORTING THIS MATERIAL. A SOIL TEST IS REQUIRED. ESTIMATED QUANITY: 1149 SF x 2' + 27 = 85 CY TOPSOIL/ PLANTER MIX 6.) PROVIDE "DEEP ROOT" BARRIERS FOR ALL NEW TREES WHICH WITHIN 6' OF CURBS. USE 7.) 13.) [ill 2' DEEP UB 24.2 x10' LONG BARRIERS CENTERED ON TRUNK TREE. PROVIDE 3" THICK LAYER OF WOOD CHIP MULCH IN ALL EXISTING AND NEW PLANTERS WITHIN THE WORK AREA. SUBMIT MULCH SAMPLE TO CITY INSPECTOR FOR APPROVAL. EXACT LOCATION OF ALL TREES SHALL BE SHOWN ON PLAN. REMOVE EXIST. CURB CAREFULLY TO PRESERVE EXISTING PLANTING AND IRRIGATION WORK AS MUCH AS POSSIBLE. ALL EXISTING SHRUBS AND TREES DAMAGED BY CONSTRUCTION SHALL BE REPLACED W/ NEW 5 GAL. SHRUBS AND 24" BOX TREES. [ill CONSTRUCT NEW CURB AND CONCRETE WALK TO AVOID DAMAGE TO EXISTING LANDSCAPE. LANDSCAPE SHEET INDEX: APPROVED FOR PLANTING "AS BUIL T11 395-1L10F2PLANT1NGPLAN &socr.97 AND IRRIGATION ONLY, 395• (abF tGATIONPLAN &socT97 INCLUDING PRECISE LOCATION OF PLANTING AREAS. E~.. ff:R'S SIG• N. TURf. RcQUIRED ON PAG~1 0 LY ::Y~ ..... W~·~--- ENGINEERING PLANCHECKER D TE TITLE ______ _ REVIE'w'ED BY1 INSPECTOR I SH1EET I CITY OF CARLSBAD 1-----1----,1----------------+----+--t----t------i PLANNING DEPARTMENT DA TE INITIAL F.NGINEER OF WORK ------------------1---t---t----r-----i REVISION DESCRIPTION DATE INITIAL DATE INITIAL ·---+--~--1 OTHER APPROVAL CITY APPROVAL COSTCO WHOLESALE GASOLINE STATION PLANTING PLAN DATE DATE /~ I I I EXISTING HEAD _/ REDIRECT NEW EMITTER LINES TO SERVE NEW AREA AS WELL D1 C -8 GPM I 1¾ I I - EXIST. 1" SLV. 1/2" LATERAL IRRIGATION NOTES /;II .• ill j U") r-- 70.5 8.7% ~ N r-- ~ ~ ' L _____________ _j U") SLEEVE TO PASS UNDER HOLDING TANK 1. MAINTAIN ALL EXISTING PLANTS WHICH ARE TO REMAIN. PROVIDE REGULAR AND SUFFICIENT WATER UNTIL THE REVISED SYSTEM IS WORKING AND NEW PLANT MATERIAL IS ESTABLISHED. 2. (7) NEW HEADS ARE SHOWN, (?)EXISTING HEADS ARE SHOWN TO BE REMOVED. THERE SHOULD BE NO NET CHANGE IN GPM THRU VALVE D1C. SERVICE EXIST FILTER [] AT EXIST. REMOTE CONTROL VALVE. r;/') 3. 4. WHERE LATERALS RUN BELOW PAVING, RUN IN SCHED. 80 PVC SLEEVE. SLEEVES TO BE 2x SIZE OF IRRIGATION PIPE, BURY MIN. 30". 5. NO NEW CONTROLLERS, ZONES, OR OR BACKFLOW DEVICES ARE REQUIRED. 6. MATCH EXISTING EQUIPMENT AND DETAILS IN ALL RESPECT EXCEPT EXCHANGE EXISTING LIDS-USE NEW PURPLE COLOR LIDS. 7. PROVIDE (4) EMITTER LINES FOR EACH TREE. AT ALL OLSON EM-12 EMITTER HEADS, DISCARD EXIST. TUBING AND REPLACE WITH NEW TUBING. S. FLUSH AND CHECK EACH TUBE TO ASSURE IT IS OPERATIONAL AND INSTALL CAP. --\ ---....__ ---....__ ----i-.'-..L :, r---RELOCATE IRRIGATION IF AND AS REQ. AT TANK VENTS - ---. - --. ....__ ---7 4 -....__ ---- ,---EXIST. PRESSURE LINE TO QUICK RELEASE COUPLERS 7 ll" < IO 0 l'- 1 m \0 I() ,-.. I() 0 IX) ..._,, <C( < w u z w n. . w VI L,J -' a,: < ::c u iffl: ~ \ s";:/H~\~l~:Jj/1--1\\:~J~~::------EXTEND EMITTER \--RELOCATE EXIST. ' . .. - \ '· •,, ' , ,, )(,'·'.': · .. ' ;; ' ' ,ii_-,._,,, .. · ,: 1--------+~---------L--'_-___ ,, ___ '_-___ ,, ___ ' __ ,,~ (f,1 ... 4 ---__ 72_.5 ----------. TUBES TO ALL \ AREA LIGHT --._AREAS, TYP.\ >\: . ·,: :. COORDINATE WITH NEW ELECTRIC ....____ .....___ '---.. "-.._ \R (!/ ~\t// //)'>'')r> / AND PHONE SERVICES WHERE '-,_ \ [ /. J/ / _/ .. \; . R / THEY ARE PROPOSED TO RUN PARALLEL. RELOCATED \_!/ ·. ";' <:,</ /"/y --------- \ --..... I ........ 1 1" sLv. uGHT------.__\ _ / ,;:;:: "/ M../,,--cAP ExIsT. ------='----=--· CJ> ' 00 ' 0 ---- --- - IRRIGATION PLAN 1" = 1(] 0 IRRIGATION LEGEND EXIST. RAINBIRD PEB SERIES REMOTE CONTROL VALVE EXIST. RAINBIRD RBY-100-200 "Y'-FILTER W/200 MESH SCREN FOR DRIP SYSTEMS IN SEPARATE VLAVE BOX X EXIST. HAMMOND HV-8401 BALL VALVE -LINE SIZE • OLSON #EH-12 EMITTER HEAD W/(12) 16 PH OUTLETS C) EXIST. OLSON #EH-12 EMITTER HEAD ~--R DENOTES HEAD TO BE REMOVED (7) DENOTES HEAD TO BE MOVED RAINBIRD 44 NP QUICK COUPLING VALVE (EXIST.) TREE, SEE L-2, N DENOTES "NEW" TREE -ALLOW FOR TREE WELLS NEW Cl 200 PVC PIPE (PURPLE COLOR) W/ SCHED. 40 FITTINGS, MIN. 12" COVER. DENOTES NEW PLANTER TO BE SERVED BY EXTENSION OF EXISTING IRRIGATION SYSTEMS. 5 \_ EXIST AREA LIGHT 70 -~ OLSON BUG CAP #i302 · \ 71 .5 V / NEW METER I 1/ PEDESTAL _/ / ELECTRICAL VAULT -{ E~ITfE~ ACCESS ~---aox W/LID(PURPLE) /EMITTER HEAD ~~ SCH, ;o PVC f'ITTING 1/2'" RADIUS, TY,a,, ,. .... \ ~ ~ r 1 /2"PR£M0LDED JOINT MATERIAL FORMED AND SACKED f• "s-'CO-'-'NT-'--. -__c"'·~-~'--1--t---"r< •• CONC. AT ARCHITECTURAi,. ~Tl / ISLAND SLAII, CONCRETE SURFACE • AC PAVll-'C Pl'LACE J/~" C.RAVE:L AS ·-...... ro ELSEWHERE INOICAfEO CONTIMUOUS :r: ,., ..., ? _ 7 ? ? ALONG WALL/FOOTING I . . INTERrACE (6"•1"). SURROUND WITH 4 oz GEOTEXTILE ......... __ . 1 ■ IJVC Sl,.[~VE AT 1 O' oe FOR WEEIJ HOLES 24'" OF PL.ANTER I W "'H+4• l.11]( SOILS _/ 1, ____ ·---------, FIRM ORIGINAL/ FOR 'H' < 18", USE DETAIL@ S01L 0~ ENGINEE:RE:D c-2 rill. CO~PACTtD TO 9~" H=1B■ TO 2,•, W::.:28" H=24" TO .'50 .. , W=.'5'" (~._)(, H::::30") 10 20 30 40 ------~,----DRIP EMITTER HEAD DETAIL NrS CURB/ WALL DETAIL WHERE 'H' EXCEEDS 1El'{MAX. 30') NrS GRAPHIC SCALE USE NEW PURPLE COVERS, TYP. 12 GPH AT 30 PSI .2 GPM (40) HEADS= 8 GPM ENGINEER'S SIGNATURE REQUIRED ON PAGE 1 ONLY APPROVED F.NGINEERING PLANCHECKER DATE APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. "AS BUILT" TITLE---~--- REVIEl,'ED BY, INSPECTOR COSTCO WHOLESALE GASOLINE STATION IR ATION PLAN APPROVED ASSISTANT ~ ..... "' "' z ' 0 ,..._ I-"' u ' w IJJ "' "' 0 u "' " I-u z w w :c :::I u w "' z 3 :s 0 w a.. "' ~ ~ w u > _J LoJ .. "' "' L,J >-z I-L,J u "' DATE DATE DATE INITIAL DATE INITIAL DATE INITIAL DWN BY: __ _ PRO ECT NO. DRAWING ND. ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL CHKD BY: __ RVl,'D BYc SOP 90-05(c) 359-1 L