Loading...
HomeMy WebLinkAboutDWG 427-2L; CDP 04-16; LA SUVERA; 01-10PROJECT LA VERA LANDSCAPE IMPROVEMENT PLANS FISHERMAN DRIVE CARLSBAD, CALIFORNIA 92008 OWNER: APPLICANT: CRAFTSMAN CARLSBAD I, LLC. 1195 LINDA VISTA ROAD, SUITE G SAN MARCOS, CA. 92069 CRAFTSMAN DEVELOPMENT CO. 1195 LINDA VISTA ROAD, SUITE G SAN MARCOS, CA. 92069 PHONE: (760) 510-6419 FAX: (760) 510-6712 LOCATION MAP Ei PROJECT LOCATION SHEET INDEX SHEET TITLE TITLE SHEET IRRIGATION PLAN/ LEGEND PLANTING PLAN/ LEGEND IRRIGATION DETAILS IRRIGATION DETAILS PLANTING DETAILS IRRIGATION AND PLANTING NOTES IRRIGATION/ PLANTING SPECIFICATIONS PLANTING SPECIFICATIONS FENCING PLAN SHEET NO. 1 2 3 4 5 6 7 8 9 10 GENERAL NOTES 1. THE CONTRACTOR MUST NOTIFY THE CITY PLAN CHECK CONSULTANT (760-815-6708) 72 HOURS (THREE WORKING DAYS), PRIOR TO STARTING CONSTRUCTION. 2. THE LANDSCAPE OR IRRIGATION CONTRACTOR IS TO VERIFY EXISTING P.S.I. AT JOB SITE PRIOR TO INSTALLING LANDSCAPE IRRIGATION SYSTEM. VERIFICATION SHALL BE MADE WITH THE APPROPRIATE WATER DISTRICT. 3. ALL REDUCED PRESSURE BACKFLOW PREVENTERS SHALL BE TESTED AFTER INSTALLATION, RELOCATION, OR REPAIRS BY A CITY APPROVED CERTIFIED TESTER. CALL 438-7152 FOR A LIST OF CITY APPROVED CERTIFIED TESTERS. DEVELOPER/OWNER IS RESPONSIBLE FOR SUPPL YING A COPY OF THE TEST RESULTS TO THE CARLSBAD MUNICIPAL WATER DISTRICT, 5959 EL CAMINO REAL, CARLSBAD, CA, 92008. 4. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING BUILDING PERMITS PRIOR TO COMMENCING WALL CONSTRUCTION. 5. IRRIGATION SYSTEMS FOR INDIVIDUAL PARCELS SHALL HAVE POINTS OF CONNECTION FOR THE SYSTEM BETWEEN THE WATER METER AND WATER SERVICE RISER INTO BUILDING AND AHEAD OF ANY WATER REGULATING DEVICE INSTALLEDFOR BUILDING. I ~•"' ' ' ·~ t ; , '.lW:1~-' ._. :; ""' ·i:,:,,;,1.~-.:1- , v,:i".;'ii;:-~ih,; ' '' ··,-, ",. ;,,,;_;:" •, ' . -·-----------------------------------------t------------------------------------------------- VICINITY MAP CITY OF OCEANSIDE HlGHWAY 78 POINSETTIA LN PROJECT LOCATIO PACIFIC OCEAN \ ALGA _r ,----..,__ AVE CITY OF ENCi NIT AS PREPARER STATEMENT I HEREBY DECLARE THAT I AM THE LICENSED DESIGNER OF WORK FOR THIS PROJECT, THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BY THE CITY OF CARLSBAD IS CONFINED TO REVIEW ONLY AND DOES NOT RELIEVE ME, AS THE LICENSED DESIGNER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. THESE PLANS HAVE BEEN PREPARED IN SUBSTANTIAL, CONFORMANCE WITH THE APPROVED LANDSCAPE CONCEPT PLAN, WATER CONSERVATION , FIRE PROTECTION PLAN, AND ALL CONDITIONS OF APPROVAL RELATED TO LANDSCAPING. ____ . .,... D DALUS DESIGN GROUP 2725 JEFFERSON STREET, SUITE 15B CARLSBAD, CALIFORNIA 92008 (760) 720-9337 DATE 4·l·C6 4'./a/o5 ENGINEERING PLANCHECKER DATE APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. "AS BUILT" TITLE ______ _ DATE REVIEWED BY: INSPECTOR DATE 1-------+----+-----------t-----f----+---+-----1 I sH~ET I CITY OF CARLSBAD ~o ::==='-===P=L=AN=N=IN:::::G:::::D:::::EP=A=RT=M=EN=T===:::....':::~==::::: LASUVERA FISHERMAN DRIVE CARLSBAD, CA. 92008 TITLE SHEET APPROVE ~ t---+--+-----------+---+--+--+----t~=~~!'te«~~~---~#00 ASSISTANT PLANNING DIRECTOR DATE DATE INITIAL ENGINEER or WORK REVISION DESCRIPTION DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL DWN BY: CHKD BY: RVWD BY: PROJECT NO. CDP 04-16 DRAWING NO, 4272L -0 -O't') . 'LSf /4 \:: \j ~. ll! : *; • ' i : *: _.. 1.5 ... ,. 1" 3/4 .............................. ................. I 3/4. 3/4 I I , ...... : .. __ / _; 20 40 1 1 FEET IRRIGATION HEAD LEGEND F @) • SYMBOL 3/4 2/3 1/2 1/3 1/4 CST EST (j) ~ [I] . , -<; .. . -, , . I " \ '.. ,· . 1· . . . . . ••-' ' '· '\. .. ! •"\ ' . / • . . SST ADJ. MANUFACTURER DESCRIPTION MODEL NO. RAINBIRD SHRUB POP-UP 1812-SAM-PRS-l 2 RAINBIRD SHRUB POP-UP 1812-SAM-PRS-l 2-VAN RAINBIRD SHRUB POP-UP 1 81 2-SAM-PRS-1 5-EST El RAINBIRD SHRUB POP-UP 1812-SAM-PRS-l 5-SST RAINBIRD SHRUB POP-UP 1 812-SAM-PRS-l 5-CST 01 HUNTER SHRUB ROTOR PGJ-12-V HUNTER SHRUB ROTOR PGJ-12-V HUNTER SHRUB ROTOR PGJ-12-V HUNTER SHRUB ROTOR PGJ-12-V [Il HUNTER SHRUB ROTOR PGJ-12-V RAINBIRD DEEP BUBBLER RWS-BCG02-SOCK I!!] RAINBIRD BUBBLER 1 404-ACV-07 S IRRIGATION EQUIPMENT LEGEND SYMBOL IZI j • • • • ' . . ' ' MANUFACTURER HUNTER CHAMPION KING BROTHERS ANY ANY ANY PER . CITY SPEC. HUNTER .. DESCRIPTION 1 Z STATION CONTROLLER ATMOSPHERIC VACUUM BREAKER BALL VALVE LATERAL LINE, TYPE 1120 PVC PIPE CLASS 200 MAIN PRESSURE LINE, PVC SCH. 40 3/4"-1 1/2", PVC CLASS 315 2" + POINT OF CONNECTION SLEEVE, PVC SCH. 40 l SLV-l LATERAL WIREBUNCH OR MAINLINE WATER METER 5/8" RAIN SENSOR DEVICE APPROVED FOR PLANTING • AND IRRIGATION ONLY, RAD PSI F 1 2' 30 1 2' 30 2.6 4'xl 5' 30 0.61 4'x30' 30 1 . 21 4'x30' 30 1.21 22' 40 1.5 25' 40 2 28' 40 2.5 30' 40 3 34' 40 4 N/A 30 0.5 N/A 30 MODEL NO. PC-1 ZOOi 262-100 BTU-E MINI-CLIK GALLONS PER MINUTE 3/4 2/3 1 /2 1 /3 1 .3 1 3 REMARKS INTERIOR INSTALLATION SIZE PER LATERAL MATCH MAINLINE SIZE 2X SIZE OF PIPE OR WIRE BUNDLE CARRIED MOUNT SO AS TO FULLY EXPOSE TO OPEN SKY II AS BUil T" 1/4 DETAIL F-4 0.65 F-4 F-4 F-4 F-4 E-4 E-4 E-4 E-4 E-4 J-5 K-5 DETAIL A-4 1-4 B-4 H-4 H-4 G-4 I ' PLOT DATE: 3/30/05'< INCLUDING PRECISE TITLE DATE ENGINEER'S SIGNATURE REQUIRED ON PAGE 1 ONLY LOCATION OF PLANTING REVIEWED BY: REVIEWED AREAS. ENGINEERING PLANCHECKER DATE INSPECTOR DATE I SH~ET I CITY OF CARLSBAD ~ PLANNING DEPARTMENT 0 LA SUVERA FISHERMAN DRIV E CARLSBAD, CA. 92008 IRRIGATION PLAN APPROVE[ 7k« . " ~-'I-II-OS ASSISTANT PLANNING DIRECTOR DATE OWN BY: DATE INITIAL PROJECT NO. DRAWING NO. REVISION DESCRIPTION DATE INITIAL DATE INITIAL CHKD BY: ENGINEER OF WORK OTHER APPROVAL CITY APPROVAL RVWD BY: CDP 04-16 4272L ,. " ·.z_ 0 24" Box 24" Box 24" Box LOT? 332 ,4 LOT 5 .332.G\ LOT:8 332.8 I / . / LOJ 3 I••-" ' . ' L----"'" ___ ....... -·· --·, ' /4 --·· / / / / 24" Box '·""i V / / LOlt 2 329.\s ··--tiOT 1 327,9 SCALE: l" ~ 20'-0" I ' ' ' ' ' ///~~•'.°' /<;;)~ // / / / _/,// ,' ' ' 20 40 so . __ 1 __ 1 _______ .jj1 FEET ' . ,.. ' .. ' - ' ' . ' . '. I , .. r -. . ,· I' ! ,.-••· / . PLANTING LEGEND I SYMBOL BOTANICAL AND COMMON NAME TREES: SHRUBS: 13 ___ , Lantana montevidensis 'Purple' V Lantana Ca llistemon citrinus _________ , Lemon Bottlebrush O ___ 1 Centranthus ruber Jupiter's Beard ----------, Coprosma x kirkii Coprosma Baccharis pilularis ---, _________ , Dwarf Coyote Brush Garrya elliptica 'James Roof' Coast Silktassel Ceanothus griseus horizantalis Carmel Creeper GROUND COVERS . w00J~---------I Gazania 'Mitsuwa White Improved' ~ Gazania -f-----, Myoporum parvifolium 'Pink' ~ Pink Myoporum BRUSH MANAGEMENT ZONE REQUIREMENTS Zone A-1 Irrigation -Yes Planting -Plant with fire retardant species, no trees or shrubs. ZoneA-2 Irrigation -Yes Planting -Plant with low fuel, naturalizing species, no trees. ZoneA-3 Irrigation -Yes QUANTITY 3 2 3 9 3 14 200 4 125 197 42 4 9 Planting -Plant with low fuel, naturalizing species, trees no closer than 20' apart. . . • ' . ' • APPROVED FOR PLANTING .... •, \ \,.-/ . ' ' ' t' . '" . ,,., .• •¼' /'-\ \ . ~ . ./ / • ' ·? ' ' ' . /. l . _, . .·• AND IRRIGATION ONLY, SIZE 24" BOX 15 GAL. 24" Box 15 GAL. 2411 Box 15 GAL. 1 GAL 5 GAL 1 GAL 1 GAL 1 GAL 5 GAL 5 GAL FROM FLATS FROM FLATS REMARKS STANDARD TRUNK STANDARD TRUNK STANDARD TRUNK STANDARD TRUNK PLANT 1 2" O .. C. PLANT 12" 0 .. C. "AS BUILT" ., .. ,<• , • • • • , ' ✓ ,·· PLOT DATE: 3/30/05:< INCLUDING PRECISE TITLE ... , ENGINEER'S SIGNATURE REQUIRED ON PAGE 1 ONLY LOCATION OF PLANTING RE'.'IEWED BY: REVIEWED AREAS. ENGINEERI NG PLANCHECKER DATE INSPECTOR I SH;ET I CITY OF CARLSBAD PLANNING DEPARTMENT LASUVERA FI SHERMAN DRIVE C ARLSBAD, CA. 92008 PLANTING PLAN APPROVED ~ ASSISTANT PLANNING DIRECTOR OWN BY : DATE INITIAL PROJECT NO. REV ISION DESC RIPT ION DATE IN ITIAL DATE INITIAL CHKD BY: ENGINEER OF WORK OTHER APPROVAL CITY APPROVAL RVWD BY: CDP 04-16 , ,. " . •." ' DETAIL I C-6 C-6 C-6 C-6 B-6 B-6 B-6 B-6 B-6 B-6 B-6 A-6 A-6 DATE DATE [1E] 0 l./--11-Cu DATE DRAWING NO. 4 27 2L I-;-] PEDESTAL MOUNT CONTROLLER L'J PER LEGEND ,:;i WALL MOUNT CONTROLLER L=J PER LEGEND 21 120 VOLT WIRE AND CONDUIT ~ IRRIGATION CONTROL WIRE CONDUIT AND CONTROL WIRE • • I ' -I 0 FINISH GRADE !] 1" IN TURF AREA. Z' IN GROUND COVER AREA_ I .;] 2000 PSI CONCRETE BASE PROVIDE ~ 6" CLEAR ALL SIDES- 5 6 7 NOTE: 1. FINAL CONTROLLER LOCATION SHALL BE PER THE OWNER AND LANDSCAPE ARCHITECT. INSTALL PER MANUFACTURER INSTRUCTIONS. 2. INCLUDE RAIN SHUTOFF DEVICE AT All CONTROLLERS, PER CITY OF CARLSBAD LANDSCAPE MANUAL. [i] PVC BALL VALVE 0 BRICK OR CONC_ SUPPORTS ALL AROUND. 0 INTEGRAL UNION (TYP.) ~ PVC MALE ADAPTER (TYP.) ~ TURF 10" ROUND PLASTIC VALVE BOX ~ WI LOCKABLE COVER. (CARSON [e] FINISH GRADE 910-10-4. COLOR TO BE GREEN) MARKED AS IRRIGATION GATE VALVE G PVC MAINLINE (TYP.) 0 COMPACTED SUBGRADE. ~ 2" IN G.C. FLUSH IN LAWN. EJ SEE LEGEND OR SPECS. @] 1 CU. FT. PEA GRAVEL (MIN.). [Q PRESSURE REGULATOR THREADED BRASS RISERS FINISH GRADE 95% COMPACTED SUBGRADE PVC COUPUNGS TxS OPTIONAL SEE PLAN & LEGEND 0 'Y' STRAINER REDUCED PRESSURE BACKFLOW DEVICE WI GATE VALVE & TEST COCKS 0 SHORT BRASS NIPPLE HEIGHT PER LOCAL CODES PVC MAINLINE, SEE LEGEND 10 MIL PIPE WRAPTYP. THRUST BLOCK G BRASS UNION 0 BRASS ELLS • . ·. NOTES: CONCRETE FOOTINGS 1 ,· ··,:-:· ' l' , ' \:=-#: u~' ~u, ~ 7 1. BACKFLOW PREVENTER MAY NOT BE INSTALLED WITHIN THE PUBLIC RIGHT-OF-WAY. 2. THERE SHALL BE NO FITTINGS OR CONNECTIONS TO OTHER FACILITIES BETWEEN THE METER AND THE BACKFLOW ASSEMBLY. 3. CONSTRUCT AZ HIGH RETAINING WALL ON 3 SIDES OF THE BACKFLOW PREVENTER WHEN INSTALLED ON 4:1 OR GREATER SLOPE. OPEN END SHALL BE AT DOWNHILL SIDE OF SLOPE. PROVIDE 2' HORIZONTAL CLEARANCE BETWEEN WALL AND BACKFLOW PREVENTER. 4. DO NOT INSTALL IN AN AREA SUBJECT TO FLOODING. 5. INSTALL PER CARLSBAD MUNICIPAL WATER DISTRICT STANDARD DRAWING W-20. CONTROLLER PVC BALL VALVE f--+-------------------------------A C REDUCED PRESSURE BACKFLOW ___ ___:-,.._.L_ NOT TO SCA_L_E ___________________________ +----"__,,,_ NOT TO SCALE NOTTO SCALE [;:] FINISH GRADE 0 MODEL PGJ GEARED ROTOR 6 E POP-UP ROTOR NOT TO SCALE 131 3/4" SCH 80 NIPPLE (LENGTH AS REQUIRED) G 314" STREET ELLS 111 ATMOSPHERIC VACUUM BREAKER, TYP. 0 P"!C SCH. 80 RISER ] PVC SCH. 80 ELL 0 PVC SCH 40 MALE ADAPTER 0 FINISH GRADE Fl IRRIGATION SPRINKLER, TYP. 2 ATMOSPHERIC VACUUM BREAKER NOTTO SCALE 2 0 PVCTEE ~ PVC LATERAL LINE 12" MIN. ABOVE HIGHEST OUTLET 10 [;:] POP-UP HEAD PER LEGEND 0 (1) MARL EX STREET Ell iol SCH. BO PVC N_IPPLE, LENGTH L::'.J AS REQUIRED G (2) MARLEX STREET ELL q. . · ,_II-ILl11 c'I' •• ' " -. --' _1_---' , • ,_: • 111-1c1-11111c:,1111- .•.•• • 111 _-- 0 0 0 Ill _,, 111:clll ---1111 111 ,---.-::,,.i '11 _, 111 ,,-I',,. . ..----L_r--,f-1-1-11 111-----11 SCH. 40 PVC SXSXT TEE ORSXT ELL 0 1/2" ABOVE FINISH GRADE PVC LATERAL LINE PER LEGEND ~ 2" AT EDGE OF PAVING OR WALL FINISH GRADE ~ SEE NOTES AND SPECIFICATIONS 5 I-;-] SAND BACKFILL COMPACT TO THE L'J DENSITY OF EXISTING SOIL 0 PAVING 0---------- 3 PIPE SIZE 0 SERVICE LINES IN SCH 40 SLEEVE ,;;7 3" WIDE RECYCLED WATER 1.D. TAPE L:'J IF APPLICABLE .. ·.·· . B A B C 111-1' D 0 CONTROL WIRES IN SCH 40 SLEEVE 0 UNDISTURBED SOIL 12: PRESSURE MAINLINE IN SCH 40 SLEEVE I 1 /2" TO 4" IN SIZE 30'' 24" 24" 4" i NOTES: NOTE: 1. PVC SLEEVES TO BE TWICE THE DIAMETER OF THE PIPE OR WIRE BUNDLE CARRIED 1. POP-UPS TO BE USED WITH IN 10' OF PEDESTRIAN USE AREAS. 2. DETAIL ALSO FOR PIPE INSTALLED IN ROCK SOIL F SHRUB AND LAWN POP-UP HEAD G\ SLEEVING -----------------------NOT TO SCALE I NOT TO SCALE ___________________________ J.___:o.....L_.:..:..:::..:~::_-:-:-:----:-:_ __ PLOT D.ATE: 3/30/05 ENGINEER'S SIGNATURE REQUIRED ON PAGE 1 ONLY REVIEWED ENGINEERING PLANCHECKER DATE --· DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION :2J REMOTE CONTROL VAL VE. 0 PVC MAINLINE. 0 VALVE BOX, SIZE AS REQUIRED. 0 SCH. 40 PVC TEE. 0 SCH. 80 PVC UNION. 0 SCH. 40 PVC ELL. G SCH. 80 PVC NIPPLE (TYP.). ~ WATER PROOF CONNECTORS. 0 SCH. 40 PVC MALE ADAPTER. EJ CONTROL WIRES WI 18" PIGTAILS. 0 PVC LATERAL LINE. @] BRICK OR CONC. SUPPORTS ALL AROUND. REMOTE CONTROL VALVE NOTTO SCALE [;:] PVC NON PRESSURE LATERAL LINE 0 PVC PRESSURE PIPE CONTROL WIRE BUNDLE (SHALL BE INSTALILED 0 ALONGSIDE PRESSURE PIPE -TAPE WIRES INTO BUNDLES AT 10' INTERVALS H TRENCH WITH PIPE & WIRES G APPROVED BACKFILL 0 UNDISTURBED SOIL El COMPACTED SUBGRADE El FINISH GRADE. @] 2" IN G.C & 1" IN LAWN AREAS. @] 2" MINIMUM El SEE LEGEND OR SPECIFICATION @] 1 CU. FT OF PEA GRAVEL . 0 FINISH GRADE 0 SEE NOTE BELOW FOR DEPTH 0 6"MIN. NOTE: • PIPE TRENCH WITHIN LANDSCAPE: MAINLINE: 1 B" NON-PRESSURE LINE: 12" • TRENCH UNDER VEHICLE PAVING: MAINLINE: 24" NON-PRESSURE LINE: 24" • SEE ALSO PRESSURE RECLAIMED WATER LINE AND POTABLE WATER LINE CROSSING DETAIL IF APPLICABLE NOTTO SCALE -----------------------------1 daedalus design group landscape architecturf•: construction 2725 jdfcrson street, .~uitc I Sh earl shad, californla 92008 pho11c 760/ 720-9337 APPROVED FOR PLANTING II AS BUil T" AND IRRIGATION ONLY, INCLUDING PRECISE TITLE DATE LOCATION OF PLANTING REVIEWED BY: AREAS. INSPECTOR DATE I S~ET I CITY OF CARLSBAD J I SHEETS I PLANNING DEPARTMENT 1 Q I LASUVERA I . ,. ----FISHERMAN DRIVE --CARLSBAD, CA. 92008 -· -·----IRRIGATION DETAILS 1 APPROVEQ>I ~ I Lf--/1-0S-. .. ,----- I ASSISTANT PLANNING DIRECTOR DATE - DWN BY: PROJECT NO. DRAWING NO. DATE INITIAL DATE INlTIAL CHKD BY: CDP 04-16 4272L OTHER APPROVAL CITY APPROVAL RVWD BY: 3 4 [,] 4-INCH GRATE 0 BUBBLER 137 ROOT WATERING SYSTEM: RAIN BIRD RWS-BCG02-SOCK ( INCWDES BUBBLER AND GRATE) ~ FINISH GRADE 0 OPTIONAL PEA GRAVEL FOR SANDY SOILS 0 1 /2-INCH PVC SCH 80 NIPPLE 0 1 /2-INCH 90-DEGREE ELBOW 0 SWING PIPE, 12-INCH ~ SWING ASSEMBLY 1 /2-INCH MAL£ NPT INLET li:"§J PVC SCH 40 TEE OR EL ~ LATERAL PIPE ~ 4-INCH BASKET WEAVE CANISTER 9 3 4 6 9 7 [,] BUBBLER 0 ACV CHECK VALVE 0 FINISH GRADE El 1 /2-INCH PVC SCH 80 NIPPLE ~ 1 /2-INCH 90-DEGREE ELBOW 0 SWING PIPE, 1 2-INCH SWING ASSEMBLY 0 1 /2-INCH MALE NPT INLET 0 PVC SCH 40 TEE OR EL [9] LATERAL PIPE NOTE: 1. BUBBLER SHALL EXTEND A MAXIMUM OF 2" ABOVE FINISH GRADE. J DEEP BUBBLER w/C?C-O:HJi:E"C~K"V~A"'L'V,cEc-------------------+-----:77:"'-:--B;::;;U""B"'B"'L"E'"R"W:..,/ C;:;,;-H;:::-EC=K"V..-A"LV.;;E;:=-----------------------1 1---_.:,._f----L~~_._-N":O,_.T_.TO SCALE NOT TO SCALE --------------------- --------------------------j---'-_.L.___:_:_:::....:_:~:..:::....:==---------·-------------~ WORST HYDRAULIC CONDITION CALCULATION CIRCUIT NO. 2, LQIJI... HGL•S5O' ELEV. OF METER -331' ELEV. OF VALVE •332' Gl'.M DEMAND 1 5...0 PSI AT METER• SSO'-331 '=219' x .433= 9S PSI -~-------~-------- I PRESSURE LOSS ITEM SERVICE LINE 1" COPPER 7.5 x 40' (.40) WATER METER 5/8" GATE VALVE 1" CONTROL VAL VE 1 " MAINLINE CL 31 5 (170') MAINLINE 1" 3.7 x (1.7) LATERAL LINE MISC. FITTING LOSS (10%) ELEVATION CHANGE 13' x .433 MINIMUM REQUIRED PRESSURE AT HEAD MINIMUM REQUIRED OPERATING PRESSURE MODEL SEE LEGEND SEE PLAN SEE LEGEND SEE LEGEND SEE LEGEND SEE PLAN SEE LEGEND OUR MINIMUM AVAILABLE STATIC PRESSURE AT THE CITY MAINLINE IS DESIGN OPERATING PRESSURE PSI 3.0 8.3 0.06 2.35 6.29 2,85 2.29 -5,63 40.00 70.77 PSI 95.0 PSI 75.00 PSI 24.23 _REMAINING PLOT DATE: 3/30/05 ENGINEER'S SIGNATURE REQUIRED ON PAGE 1 ONLY REVIEWED ~ ENGINEERING PLANCHECKER DATE DATE INITIAL REVISION DESCRIPTION -.. ENGINEER OF WORK LATERAL LINE --·· GPM PIPE SIZE PSI LOSS/1 00' RUN LENGTH LOSS/RUN - 2.0 3/4" 0,22 4.0 3/4" 0.79 5,0 3/4" 1.20 7.5 3/4" 2.54 15 1" 2,77 22' (.22) 20.5' (,205) 12'(.12) 17' (.17) 7S' (.75) TOTAL . '"'E: .,....,- \· 1;, {'. :;• ,-.. · .05 .16 ,14 .43 2.07 2.85 PSI daedalus design group landscape architecture : construction 2725 jet'fcr~on street, suite 1 Sh earl shad, ctlirornia 920()8 phone 760/ 720-0317 APPROVED FOR PLANTING II AS BUil T" AND IRRIGATION ONLY, INCLUDING PRECISE TITLE DATE LOCATION OF PLANTING REVIEWED BY: AREAS. INSPECTOR DATE I SH;ET Ii CITY OF CARLSBAD ~ PLANNING DEPARTMENT D ,-~-LASUVERA 7 FISHERMAN DRIVE CARLSBAD, CA. 92008 IRRIGP.TION DETAILS ~ APPROVH ~ '-I-I !_--OS-I .... DATE , ASSISTANT PLANNING DIRECTOR ~- OWN BY: PROJECT NO. DRAWING NO. DA1E INITIAL DATE INITIAL CHKD BY: CDP 04-16 4272L OTHER APPROVAL CITY APPROVAL RVWD BY: t EQUAL / I SHRUB (TYP.) ~ SET SHRUB CROWN 1" ABOVE ~ FINISH GRADE 0 PREPARED BACKFILL NIX, PUDDLE ~ FINISH GRADE AND SETTLE BACKFILL PRIOR TO PLANTING TO AVOID ROOTBALL SETTLING [s] PLANT FERTILIZER TABLETS, PER SEE PLANTING NOTES FOR BACKFILL MIX. 0 0 2" MULCH LAYER PER PLANTING PLANTING NOTES NOTES 0 SCARIFY SOIL ALONG SIDES AND [s] PLANT ROOTBALL, TOP TO BE 1" BOTTOM OF PLANTING PIT. ~ ~ 4" HIGH WATER RETENTION BASIN ABOVE FINISH GRADE PREPARE RAKE OUT AFTER 90 DAYS U.0.N. PER PLANTING NOTES. EDGE OF PLANTIN'.:7 NOTES: 1. ALL GROUND COVER IS TO BE PLANTED IN A TRIANGULAR GRID. 2. FOR PLANT ON CENTER SPACING SEE PLANT LEGEND A GROUND COVER PLANTING B TREE AND SHRUB PLANTING (1 GAL. THRU 24' BOX) -'------------ NOTTO SCALE ==----------------NOTTO SCALE TREE PER PLAN (2) CINCH TIES, TACK TO STAKE TO PREVENT SLIPPING (2) 2" DIA. X 8' LONG TREATED LODGE POLE PINE STAKES FOR 5 GAL TREES. OR (2) 2" DIA. X 10' LONG TREATED LODGEPOLE PINE TAKES FOR 15 GAL.· 24" BOX TREES, SET STAKES OUTSIDE ROOTBALL. 1 " t:-----El .JI.-----G [s] Ll Roi1fALL G [51 0 0 TREE CANOPY ROOT BALL DO NOT PENETRATE) CINCH TIES, TACK TO STAKE TREATED LODGEPOLE PINE STAKE PLAN VIEW NOTES: 1) INSTALL TREE TIES AND STAKES ONLY TO PROPER LEVEL TO HOLD TREE UPRIGHT. PROPER HEIGHT IS 6" ABOVE POINT WHERE THE TREE WILL SNAP TO AN UPRIGHT POSITION BY ITSELF IF TOP IS PULLED TO ONE SIDE AS IF WIND LOADED AND THEN RELEASED. 2) TREES SUPPLIED WITH TOPS TOO LARGE FOR TRUNKS TO SUPPORT SHALL BE PRUNED AS DIRECTED BY LAND. ARCH. TO REDUCE CROWN WEIGHT OR PRUNED TO A NEW LEADER DO NOT REMOVE LATERALS ALONG TRUNK. C TREE STAKING (5 GAL. THRU 24" BOX) ---'----------------- NOTTO SC ALE ---------------------------------+---------------------- PLOT DATE: 3/30/05 ENGINEER'S SIGNATURE REQUIRED ON PAGE 1 ONLY REVIEWED ENGINEERING PLANCHECKER DATE ~- DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION daedalus design group landscape architecture: construction 2725 jdfcrson street, suite I Sh carl~had, rnllfornia 92008 phone 760/ 720-9337 APPROVED FOR PLANTING "AS BUil T" AND IRRIGATION ONLY, INCLUDING PRECISE TITLE DATE LOCATION OF PLANTING REVIEWED BY: AREAS. INSPECTOR DATE I SH~ET I CITY OF CARLSBAD ] I SHEETS I PLANNING DEPARTMENT 10 I LASUVERA FISHERMAN DRIVE CARLSBAD, CA. 92008 PLANTING DETAILS APPROVE[ ~.,/,I I '" lf-1/,0S- ASSISTANT PLANNING DIRECTOR DATE DWN BY: 3 PROJECT NO. DRAWING NO. DATE INITIAL DATE INITIAL CHKD BY: ~-CDP 04-16 4272L OTHER APPROVAL CITY APPROVAL RVWD BY: PLANTING NOTES 1. LANDSCAPE CONTRACTOR SHALL RECEIVE THE SITE WITHIN PLUS OR MINUS .1 0 FEET OF FINISH GRADE. 2. THE PLANTING PLANS ARE DIAGRAMMATIC. MINOR ADJUSTMENTS IN PLANT LOCATIONS MAY BE MADE AT THE DISCRETION OF THE LANDSCAPE ARCHITECT. 3. THE LANDSCAPE CONTRACTOR WILL COORDINATE HIS WORK WITH THE OTHER TRADES AND MAINTAIN DRAINAGE DURING CONSTRUCTION!. 4. PLANT QUANTITIES AND AREAS SHOWN ON LEGENDS ARE FOR CONTRACTOR'S CONVENIENCE IN ESTIMATING ONLY. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING PLANT MATERIALS TO COVER ALL AREAS AS SHOWN ON PLANS. 5. LANDSCAPE ARCHITECT, OWNER, OR OWNER'S REPRESENTATIVE SHALL APPROVE FINAL PLACEMENT OF ALL TREES, SHRUBS, AND VINES PRIOR TO PLANTING. 6. TREE AND SHRUB PITS 1 5 GALLONS OR SMALLER SHALL BE TWO TIMES ROOTBALL DIAMETER WIDE AND EQUAL WITH ROOTBALL DEPTH. TREE AND SHRUB PITS FOR 20" BOX AND LARGER SHALL BE 1 ·· l /2 TIMES ROOTBALL DIAMETER WIDE AND EQUAL WITH ROOTBALL DEPTH. 7. TREE GUYING SHALL BE DONE AT CONTRACTOR/OWNER DISCRETION (PER DETAIL). CONTRACTOR SHALL BE RESPONSIBLE FOR THE TREE'S STABILITY DURING THE LENGTH OF THE GUARANTEE PERIOD. ALL STAKING AND GUYING MATERIALS SHALL BE REMOVED AT THE END OF THE 1-YEAR TREE GUARANTEE PERIOD. 8. -- 9. THE CONTRACTOR SHALL USE THE FOLLOWING BACKFILL SCHEDULE FOR BIDDING PVRPPSES ONLY, A SOIL TEST SHALL BE MADE AS PART OF THIS CONTRACT, AND RECOMMENDED AMENDMENTS SHALL BE USED FOR ACTUAL INSTALLATION. PLANTING BACKFILL MIX FOR ALL CONTAINER PLANTS EXCEPT FERNS, AZALEAS, CAMELLIAS, OR AS NOTED IN PLAN. ON SITE SOIL NITROLIZED ORGANIC AMENDMENT GROW-POWER PLUS FERTILIZER AGRICULTURAL GYPSUM PREMIUM GREEN IRON BY GROW-POWER 6 CU. YDS. 1 CU. YDS. 16 LBS./C.Y. 4 LBS./C.Y. l LB./C.Y. PLANTING BACKFILL MIX FOR ALL FERNS, AZALEAS, CAMELLIAS SHALL CONSIST OF 1 /3 EXISTING SITE SOIL, 1 /3 ORGANIC AMENDMENT AND 1 /3 THOROUGHLY WETTED PEATMOSS, MIXED TO A UNIFORM PLANTING MEDIUM, AND WATERED IN AFTER PLANTING WITH TERRA-SOL OR APPROVED EQUIVALENT WETTING AGENT. 10. ALL PLANTS 1-GALLON SIZE OR LARGER SHALL RECEIVE AGRIFORM 27-GRAM 20-10-5 FERTILIZER TABLETS AT THE FOLLOWING RATES: 7 -GALLON: ONE 5-GALLON: TWO 15-GALLON: THREE BOXED TREES: ONE PER l /2" CALIPER PLACE TABLET 6-8" DEEP AND IN CONTACT WITH ROOTBALL. 11. ALL PLANTS INSTALLED FROM FLATS SHALL RECEIVE ONE AGRIFORM 5-GRAM 20-10-5 TABLET EACH, MIXED WITH A HANDFUL OF MULCH AND BACKFILL. 12. ALL PLANTS EXCEPT BOUGAINVILLEAS PLANTED FROM CONTAINERS SHALL HAVE THEIR ROOTBALLS SCORED WITH A SHARP TOOL TO A DEPTH OF l" IN THREE LONGITUDINAL INCISIONS AT LOCATIONS SPACED AROUND THE ROOTBALL BEFORE PLACING PLANT IN PLANTING HOLE. BOUGAINVILLEAS SHALL BE PLANTED WITH INTACT ROOTBALLS, BROKEN ROOTBALLS WILL BE NOT BE ACCEPTED. 13. ALL TYING MATERIALS AND MARKING TAPES SHALL BE REMOVED AT THE TIME OF PLANTING. 14. STAKES SHALL BE REMOVED FROM VINES, THEN TRAINED TO WALL, POST, OR COWMN PER PLANTING DETAIL. l 5. CONTRACTOR SHALL VERIFY ALL PLANTING AREA SIZES AND THE EXTENT OF THEIR PLANTING. IF ANY DISCREPANCIES OCCUR, PLEASE BRING THESE TO THE ATTENTION OF THE OWNER AT THE TIME YOUR BID IS SUBMITTED. 16. ALL BOXED TREE PITS ARE TO BE EVALUATED FOR DRAINAGE. THE TEST CONSISTS OF FILLING THE PITS WITH WATER TO A DEPTH OF l 2" TWO TIMES OVER A 48 HOUR PERIOD. IF THE WATER LEVEL HAS NOT MOVED DOWN AT LEAST l /4" PER HOUR OR MORE, THE PLANTING PIT SHOULD BE CONSIDERED TO HAVE POOR DRAINAGE CHARACTERISTICS. THE CONTRACTOR IS TO CONTACT THE LANDSCAPE ARCHITECT AND A DRAINAGE PROGRAM WILL BE DEVISED FOR THE SITE'S SPECIFIC CONDITIONS. 17. THE FOLLOWING SHALL BE APPLIED FOR 1,000 SQ. FT. OF PLANTING AREA AND MECHANICALLY OR HAND TILLED INTO THE SOIL TO A DEPTH OF 6" TO 8" FOR ALL LANDSCAPED AREAS WITH A SLOPE OF 3:1 OR LESS. SEE HYDROSEEDING SPECIFICATIONS FOR SOIL PREPARATION FOR SLOPE CONDITIONS. THE CONTRACTOR SHALL USE THE FOLLOWING BACKFILL SCHEDULE FOR BIDDING PUllEQS.ES ONLY. A SOIL TEST SHALL BE MADE AS PART OF THIS CONTRACT. AND RECOMMENDED AMENDMENTS SHALL BE USED FOR ACTUAL INSTALLATION. AGRICULTURAL GYPSUM AGRIFORM 18-1 8-6 FERTILIZER PREMIUM GREEN IRON BY GROW POWER NITROLIZED ORGANIC AMENDMENT 100 LBS. 25 LBS. 10 LBS. 5 CUBIC YARDS 18. NO IRON SULFATE SHALL COME IN CONTACT WITH ANY MASONRY SURFACE. 19. SLOPE ALL PLANTING AREAS AWAY FROM BUILDING AT 2% MINIMUM FOR 5 FEET MINIMUM, WHERE APPLICABLE. 20. LAWN AREAS SHALL HAVE A MAXIMUM SLOPE INCLINE OF 4:1, GROUND COVER TO BE 2:1 U.0.N. (UNLESS OTHERWISE NOTED). 21. CONTRACTOR SHALL VERIFY LOCATION OF ALL UNDERGROUND UTILITIES AND SERVICES PRIOR TO ANY DIGGING. CONTRACTOR ASSUMES FULL RESPONSIBILITY FOR ALL DAMAGE CAUSED BY FAILURE TO DO SO. 22. ANY SUBSTITUTION MUST BE APPROVED IN WRITING BY LANDSCAPE ARCHITECT, AND THE CITY OF CARLSBAD INSPECTOR PRIOR TO BEING INSTALLED. 23. GROUND COVER IS NOT SHOWN UNDER SHRUBS FOR GRAPHIC CLARITY. GROUND COVERS ARE TO BE PLANTED WITHIN ALL SHRUB DRIPLINES U.O.N. 24. PRIOR TO PLANTING, THE IRRIGATION SYSTEM SHALL BE FULLY OPERATIONAL. ALL PLANTING AREAS SHALL BE THOROUGHLY WATERED IMMEDIATELY AFTER PLANTING AND APPLICATION OF FERTILIZER. 25. LANDSCAPE CONTRACTOR SHALL REMOVE ALL EXISTING VEGETATION, TRASH, CLIPPINGS, ROCK, AND OTHER DEBRIS FROM THE SITE AND DISPOSE OF IT AT AN APPROVED DISPOSAL SITE. ADDITIONALLY, THE CONTRACTOR SHALL RAKE AND FINE GRADE ALL AREAS TO BE PLANTED PRIOR TO THE COMMENCEMENT OF PLANTING OPERATIONS. 26. ALL TREES PLANTED WITHIN 10' OF FLATWORK AREA ARE TO HAVE A DEEP ROOT BARRIER INSTALLED. BARRIER TO BE BY DEEP ROOT CORPORATION, MODEL UB-24-2, INSTALL PER MANUFACTURER'S SPECIFICATIONS. 27. CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ANY REPAIRS MADE NECESSARY THROUGH THE ACTIONS OR NEGLIGENCE OF HIS OR HER CREW. 28. ALL PLANTED AREAS ARE TO HAVE A 3" LAYER OF WALK ON BARK BY BUTLERS MILL OR EQUAL APPLIED TO GROUND SURFACE, SEE PLANTING PLAN FOR AREAS. ONLY AREAS HAVING A 2:1 OR GREATER SLOPE CONDITION AND AREAS INDICATED AS BEING LAWN OR HAVING A LIVING GROUND COVER PLANTED ARE EXEMPT FROM THIS MULCHING PROGRAM. DO NOT MOUND MULCH DIRECTLY AROUND PLANT TRUNK, LEAVE AN AREA OF APPROXIMATELY 3" BARE AROUND BASE OF ALL TREES AND SHRUBS. THE CONTRACTOR IS TO SUBMIT A SAMPLE OF THE MULCH MATERIAL FOR APPROVAL BY THE CITY INSPECTOR, OWNER, AND LANDSCAPE ARCHITECT, PRIOR TO BULK DELIVERY TO JOB SITE. 29. IF IMPORTED SOIL IS REQUIRED TO BUILD THE LANDSCAPE MOUNDS, FIRST SPREAD A 6" LAYER ATOP THE AREA THE MOUND IS TO BE PLACED AND TILL INTO THE EXISTING SITE SOIL. AFTER THE TWO SOILS HAVE BEEN MIXED THOROUGHLY, YOU MAY THEN CONTINUE BUILDING THE MOUNDS TO THE SPECIFIED HEIGHTS. ANY IMPORTED TOPSOIL USED FOR THIS PURPOSE WILL BE REQUIRED TO MEET THE FOLLOWING REQUIREMENTS: THE IMPORTED TOPSOIL WILL BE REQUIRED TO MEET THE FOLLOWING SPECIFICATIONS: PH BETWEEN 6 AND 7.6, CONTAINING FROM 5 TO 20 PERCENT ORGANIC MATTER AS DETERMINED BY THE ORGANIC CARBON 6A CHEMICAL ANALYSIS METHOD DESCRIBED IN THE USDA SOIL SURVEY INVESTIGATION REPORT NO. l. MAXIMUM PARTICLE SIZE TO BE 3/4" WITH MAXIMUM 3 PERCENT RETAINED ON 1/4" SCREEN. SOLUBLE SALTS SHALL NOT EXCEED 600 PPM. OTHER COMPONENTS SHALL BE WITH THE FOLLOWING PERCENTAGES: SILT 25% -50% CLAY l 0% -30% SAND 20% -35% 30. GUARANTEE: ALL TREES FOR ONE YEAR, SHRUBS FOR NINETY DAYS, AND GROUND COVERS AND LAWN FOR THIRTY DAYS. 31. LANDSCAPE CONTRACTOR SHALL MAINTAIN ALL GENERAL PLANTINGS FOR A PERIOD OF JD DAYS. 32. THE MAINTENANCE PERIOD SHALL INCLUDE THE FOLLOWING SCOPE OF WORK. A. REQUIRED WATERING TO MAINTAIN HEALTHY PLANTS. B. REMOVAL OF WEEDS FROM LAWN GROUND COVER AND ANY SHRUB BEDS. C. REPLACEMENT OF ANY DEAD, DYING, OR DAMAGED TREES, SHRUBS, AND GROUND COVER. D. FILLING AND REPLANTING ANY LOW AREAS WHICH RETAINED STANDING WATER THUS CAUSING PLANT DAMAGE OR FAILURE E. ADJUSTING OF SPRINKLER HEAD HEIGHTS AND WATERING PATTERNS TO INSURE HEAD TO HEAD COVERAGE F. FILLING AND RECOMPACTION OF ANY ERODED AREAS. G. WEEKLY REMOVAL OF ALL TRASH, LITTER, CLIPPINGS, AND FOREIGN DEBRIS. H. MOWING AND TRIMMING OF ALL TURF AREAS. TURF IS NOT TO EXCEED 3" IN HEIGHT BEFORE MOWING OPERATIONS. COLLECT GRASS CLIPPINGS DURING MOWING OPERATIONS AND REMOVE FROM SITE. 1. AT THIRTY DAYS AFTER PLANTING, ALL PLANTED AREAS WITH (OVERHEAD IRRIGATION) IS TO BE FERTILIZED WITH 20 LBS OF GROW POWER 5-3-1 OR EQUAL PER l 000 SQ. FT. IF (DRIP IRRIGATED) APPLY MIRACLE GROW PER l 000 SQ. FT. OF AREA PER MANUFACTURERS SPECIFICATIONS. 33. PRIOR TO THE END OF THE MAINTENANCE PERIOD, THE LANDSCAPE CONTRACTOR SHALL CONTACT THE OWNER TO ARRANGE A FINAL WALKTHROUGH. OWNER MUST ACCEPT ALL MAINTAINED AREAS IN WRITING BEFORE THE MAINTENANCE PERIOD CAN BE CONSIDERED COMPLETE. 34. ALL BOXED TREES AND FIELD GROWN TREES SHALL BE APPROVED BY THE OWNER OR THEIR REPRESENTATIVE PRIOR TO DELIVERY TO THE PROJECT SITE. IRRIGATION NOTES 1 . CONTRACTOR SHALL INSTALL IRRIGATION SYSTEMS THAT ARE COMPLETE AND FUNCTIONING IN EVERY WAY. 2. PLANS ARE DIAGRAMMATIC AND APPROXIMATE. PRECISE LOCATION OF HEADS SHALL BE FIELD ADJUSTED TO MEET MINOR VARIATIONS IN PLAN. 3. CONTRACTOR SHALL CHECK AND VERIFY ALL SITE CONDITIONS, UTILITIES, AND SERVICES PRIOR TO TRENCHING. 4. CONTRACTOR SHALL CHECK AND VERIFY STATIC WATER PRESSURE READING OF Z:, PSI AT STREET PRIOR TO BEGINNING OF WORK. NOTIFY LANDSCAPE ARCHITECT OF ANY DISCREPANCY. 5. POINT OF CONNECTION (POC) SHALL BE AT METER. 6. CONTRACTOR SHALL FIELD VERIFY SIZE OF WATER METER BEFORE WORK COMMENCES, MINIMUM SIZE TO BE 51.a"_NOTIFY LANDSCAPE ARCHITECT OF ANY DISCREPANCY. 7. NO PRESSURE REGULATOR NEEDED FOR THIS PROJECT. - 8. DIRECT BURIAL CONTROL WIRE SHALL BE 24 VOLT, SINGLE CONDUCTOR SOLID COPPER, PLASTIC INSULATED CABLE RATED FOR DIRECT BURIAL APPLICATIONS, UF, UL APPROVED, 14-GAUGE (MINIMUM) PILOT WIRE, 1 2-GAUGE (MINIMUM) FOR COMMON GROUND RETURN WIRE. SIZE OF WIRE FOR RUNS OVER l 00' LONG SHALL BE PER MANUFACTIJRER'S SPECS. 9. CONTRACTOR SHALL BE RESPONSIBLE FOR SLEEVES AND CHASES UNDER PAVING, THROUGH WALLS, ETC. UNLESS OTHERWISE NOTED. SOME LATERAL PIPE RUNS ACROSS THE DRIVEWAY WILL REQUIRE WATER JETTING, SEE PLANS FOR LOCATIONS. SLEEVING SHALL BE MARKED AT EACH END OF FLATWORI< OR WALLS BY A PAINT DOT. 10. CONTRACTOR SHALL NOTE LOCATIONS OF TREES ON PLANTING PLAN AND SHALL ROUTE IRRIGATION PIPE AND PLACE HEADS TO PREVENT CONFLICTS WITH TREE PLANTING. GROUP VALVES IN BOXES, PARALLEL TO EACH OTHER, IN PLANTING AREAS. LOCATE PIPE ALONG EDGE OF PLANTING AREAS WHEREVER POSSIBLE. 11. FLUSH ALL PIPES CLEAN PRIOR TO INSTALLING SPRINKLER HEADS. 12. ALL HEADS TO BE 2" FROM CURBS AND WALKS, AND 6" FROM BUILDING UON. 13. PROVIDE CHECK VALVES OF CORRECT LINE SIZE WHERE FIELD CONDITIONS DEMAND, PER PLANS, AND/OR AS REQUIRED. (TO PREVENT LOW HEAD DRAINAGE) 14. CONTROL WIRES SHALL BE BUNDLED WITH ELECTRICAL TAPE AT 8'-0" INTERVALS AND BURIED BENEATH MAINLINE WHERE POSSIBLE OR AT THE SAME DEPTH AS MAINLINE ALONG EDGES OF PLANTING AREAS. l 5. CONTRACTOR SHALL ADJUST ALL IRRIGATION HEADS TO COMPLETELY COVER PLANTING AREAS WHILE AVOIDING WALKS, BUILDINGS, POSTS, COLUMNS, AND WINDOWS. 16. ALL TRENCHES SHALL BE WETTED AND RECOMPACTED TO 90% MINIMUM UNDER FLA TWORK AND 85% IN PLANTING AREAS. 17. IRRIGATION SYSTEM IS SHOWN DIAGRAMMATICALLY. LOCATE ALL PIPE AND EQUIPMENT WITHIN PLANTING AREAS. GROUP PARALLEL PIPE IN SINGLE TRENCHES WHERE POSSIBLE. 18. ANY SUBSTITUTION MUST BE APPROVED IN WRITING BY LANDSCAPE ARCHITECT. 19. ALL IRRIGATION MATERIALS AND PROCEDURES SHALL CONFORM TO ALL LOCAL, MUNICIPAL, AND STATE LAWS, RULES AND REGULATIONS GOVERNING OR RELATING TO ANY PORTION OF THIS WORK AND ARE HEREBY INCORPORATED INTO AND MADE A PART OF THESE NOT ES AND THEIR PROVISIONS SHALL BE CARRIED OUT BY THE IRRIGATION CONTRACTOR. 20. IRRIGATION CONTRACTOR SHALL GUARANTEE THE ENTIRE IRRIGATION SYSTEM TO BE FREE OF DEFECTS IN WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR FROM FINAL ACCEPTANCE BY THE OWNER. 21 . THE CONTRACTOR SHALL OBTAIN AN IRRIGATION COVERAGE APPROVAL FROM THE LANDSCAPE ARCHITECT (IF RETAINED TO PROVIDE PROJECT OBSERVATION DUTIES) PRIOR TO PLANTING. CONTACT LANDSCAPE ARCHITECT AT LEAST 48 HOURS IN ADVANCE OF DESIRED INSPECTION TIME. 22. TRENCHES SHALL BE MADE WIDE ENOUGH TO ALLOW A MINIMUM OF 4" BETWEEN PARALLEL PIPE LINES. NO STACKING OF PIPES VERTICALLY WITHIN THE SAME TRENCH IS TO BE ALLOWED. TRENCHES FOR PIPE LINES SHALL BE MADE OF SUFFICIENT DEPTHS TO PROVIDE THE MINIMUM COVER FROM FINISH GRADE. 23. INSTALL POP-UPS WITHIN 10' OF ANY PEDESTRIAN USE AREA. 24. INSTALL CHECK VALVES AS NEEDED TO PREVENT LOW HEAD DRAINAGE. daedalus design group landscape architecture: construction 2725 jellei-son slre~t. suite 15h carlshaJ., 'california 92008 phone 760/ 720-9337 APPROVED FOR PLANTING "AS BUil T" AND IRRIGATION ONLY, PL.OT DA TE: 3/30/05 INCLUDING PRECISE TITLE DATE ENGINEER'S SIGNATURE REQUIRED ON PAGE 1 ONLY LOCATION OF PLANTING REVIEWED BY: REVIEWED AREAS. ENGINEERING PLANCHECKER DATE INSPECTOR DATE I SH~ET I CITY OF CARLSBAD CTE PLANNING DEPARTMENT 0 LA SUVERA -·-·· FISHERMAN DRIVE ·-·-CARLSBAD, CA. 92008 PLAN "' NG AND IRRIGATION NOTES APPROVED -X~, ,1 L.,l-l/-cJ0. .. ASSISTANT PLANNING DIRECTOR DATE ·--~ DATE INITIAL OWN BY: I PROJECT NO. DRAWING NO. I DATE INITIAL DATE INITIAL REVISION DESCRIPTION CHKD BY: . ' ENGINEER or WORK OTHER APPROVAL CITY APPROVAL RVWD BY: CDP 04-16 4272L i ......0 ..... 0 +>~ IRRIGATION SPECIFICATIONS PART 1 -GENERAL 1.01 DESCRIPTION A. WORK DISCUSSED IN THIS SECTION INCLUDES THE FURNISHING OF ALL LABOR, MA TE RIALS, AND EQUIPMENT REQUIRED TO COMPLETE WORK INDICATED ON THE DRAWINGS. THE WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE BEST STANDARDS OF PRACTICE RELATING TO THE VARIOUS TRADES AND UNDER THE CONTINUOUS SUPERVISION OF A COMPETENT FOREMAN, CAPABLE OF INTERPRETING THE DRAWINGS, NOTES, AND THESE SPECIFICATIONS. 8. IRRIGATION AND LANDSCAPE WORK MAY BE DONE CONCURRENTLY, HOWEVER, LANDSCAPE WORK MAY NOT START IN ANY SECTION PRIOR TO INSPECTION AND APPROVAL OF THE SPRINKLER WORK. C. PRIOR TO EXCAVATION FOR IRRIGATION PIPE, LOCATE ALL ELECTRICAL CABLES, CONDUITS, AND ALL UTILITY LINES SO THAT PROPER PRECAUTIONS MAY BE TAKEN NOT TO DAMAGE SUCH IMPROVEMENTS. IN THE EVENT OF A CONFLICT BETWEEN SUCH LINES AND PIPE LOCATIONS, PROMPTLY NOTIFY THE LANDSCAPE ARCHITECT WHO SHALL ARRANGE FOR RELOCATION OF ONE OR THE OTHER. FAILURE TO FOLLOW THIS PROCEDURE PLACES UPON THE CONTRACTOR THE RESPONSIBILITY FOR (AT HIS OWN EXPENSE) MAKING ANY AND ALL REPAIRS FOR DAMAGE RESULTING FROM WORK HEREUNDER. 1.02 SPECIAL CONDITIONS THE GENERAL CONDITIONS ARE A PART OF THIS SECTION AND THE CONTRACT FOR THIS WORK AND APPLY TO THIS SECTION FULLY AS IF REPEATED HERE. 1.03 GENERAL REQUIREMENTS 1.04 FURNISH AND INSTALL IRRIGATION SYSTEM INCLUDING, ANY INCIDENTAL WORK NOT SHOWN OR SPECIFIED WHICH CAN REASONABLY BE INFERRED AS PART OF THE WORK, AS NECESSARY TO PROVIDE A COMPLETE AND WORKABLE SYSTEM. WORK INCLUDED THE FOLLOWING ITEMS ARE DETERMINED TO BE A PART OF TIHE IRRIGATION WORK WHEN APPLICABLE TO THE PLANS. A. P.0.C. CONNECTION OF SYSTEM TO NEW WATER MAIN AND METER. B. REVIEW OF UTILITY PLANS SHOWING OTHER UNDERGROUND FACILITIES. C. TRENCHING AND BACKFILL. D. ALL IRRIGATION MATERIAL AND EQUIPMENT INDICATED ON DRAWINGS. E. AUTOMATIC CONTROLLER AND ELECTRICAL CONNECTION. F. WATER CONNECTION G. PRE CONSTRUCTION MEETING WITH CITY INSPECTOR@ (760) 815-6708 1.05 WORK NOT INCLUDED A. ELECTRICAL STUB-OUT B. WATER METER INSTALLATION 1 .06 CODES, RULES, AND SAFETY ORDERS A. ALL WORK AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH THE LATEST RULES AND REGULATIONS OF THE SAFETY ORDERS OF THE DIVISION OF INDUSTRIAL SAFETY; THE UNIFORM PLUMBING CODE PUBLISHED BY THE WESTERN PLUMBING OFFICIALS' ASSOCIATION; AND OTHER APPLICABLE LAWS OR REGULATIONS. NOTHING IN THESE DRAWINGS OR SPECIFICATIONS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. SHOULD TIHE CONSTRUCTION DOCUMENTS, OR INSTRUCTION BE AT VARIANCE WITH THE AFOREMENTIONED RULES AND REGULATIONS, NOTIFY THE LANDSCAPE ARCHITECT, AND AWAIT HIS INSTRUCTIONS BEFORE PROCEEDING WITH THE WORK AFFECTED. 1.07 PERMITS AND FEES A. OBTAIN ALL PERMITS AND PAY REQUIRED FEES TO ANY GOVERNMENTAL AGENCY HAVING JURISDICTION OVER THE WORK. ARRANGE FOR INSPECTIONS REQUIRED BY LOCAL ORDINANCES DURING THE COURSE OF CONSTRUCTION AS REQUIRED. ON COMPLETION OF THE WORK, SATISFACTORY EVIDENCE SHALL BE FURNISHED TO LANDSCAPE ARCHITECT TO SHOW THAT ALL WORK HAS BEEN INSTALLED IN ACCORDANCE WITH THE ORDINANCES AND CODE REQUIREMENTS. 1.08 APPROVAL A. WHEREVER THE TERMS "APPROVE," "APPROVAL," OR "APPROVED" ARE USED IN THE SPECIFICATIONS, THEY SHALL MEET THE APPROVAL OF THE LANDSCAPE ARCHITECT AND CITY INSPECTOR IN WRITING. 1.09 SCHEDULE OF WORK A. SCHEDULE AND COORDINATE THE ELECTRICAL AND WATER CONNECTIONS, AND THE PLACEMENT OF MATERIAL AND EQUIPMENT IN A MANNER THAT WILL EFFECT THE EARLIEST COMPLETION OF THE WORK IN CONFORMANCE WITH THE CONSTRUCTION PROGRESS SCHEDULE. PART 2 -DELIVERY, STORAGE, AND HANDLING 2.01 NOTIFICATION A. PROVIDE NOTIFICATION OF THE DELIVERY SCHEDULE IN ADVANCE SO MATERIAL MAY BE INSPECTED UPON ARRIVAL AT THE JOB SITE. REMOVE UNACCEPTABLE MATERIAL FROM THE JOB SITE IMMEDIATELY. 2.02 PROTECTION A. PROTECT WORK AND MATERIALS UNDER THIS SECTION FROM DAMAGE DURING CONSTRUCTION AND STORAGE. POLYVINYL CHLORIDE (PVC) PIPE AND FITTINGS SHALL BE SHIELDED FROM DIRECT SUNLIGHT. B. ASSUME ALL RESPONSIBILITY FOR DAMAGE TO EXISTING CONSTRUCTION, AND RESTORE PROPERTY TO ITS ORIGINAL CONDITION SHOULD DAMAGE OCCUR AS A RESULT OF THE WORK OF THIS SECTION. C. HANDLE PLASTIC PIPE AND FITTINGS CAREFULLY AND STORE UNDER COVER TO AVOID DAMAGE. BEDS ON WHICH MATERIALS ARE STORED MUST BE FULL LENGTH OF PIPE TO AVOID DAMAGE. ANY PIPE THAT HAS BEEN DAMAGED OR DENTED SHALL NOT BE USED IN THE WORK. PART 3 -MATERIALS 3.01 CONDITION OF DELIVERY A. ALL MA TE RIALS THROUGHOUT THE SYSTEM SHALL BE NEW AND IN PERFECT CONDITION. NO DEVIATIONS FROM THE SPECIFICATIONS SHALL BE ALLOWED. THE DECISION OF LANDSCAPE ARCHITECT SHALL BE FINAL IN THE DETERMINATION OF THE QUALITY OF MATERIALS AND EQUIPMENT. FOR ALL MATERIALS AN INVOICE SHALL BE SUBMITTED SHOWING QUANTITIES OR MATERIALS. 3.02 DESCRIPTION A. PLASTIC PIPING: ALL MAIN LINE PIPE SHALL BE AN APPROVED BRAND, CLASS 315, TYPE 1220 PVC FOR LINES 2" AND LARGER AND SCHEDULE 40 FOR LINES 1 1/2" AND SMALLER. ALL LATERAL PIPE TO SPRINKLERS SHALL BE CLASS 200, TYPE 1120-1220 POLYVINYL CHLORIDE (PVC) PIPE. ALL PIPE SHALL CONFORM TO ASTM Dl 785 AND ASTM D2241. B. PLASTIC FITTINGS: SCHEDULE 40, POLYVINYL CHLORIDE (PVC) STANDARD WEIGHT, AS MANUFACTURED BY SLOANE, LASCO, OR AN APPROVED EQUAL, ASTM D2464, ASTM D2466, OR ASTM D2467 AS REQUIRED. C. SOLVENT CEMENT: COMPATIBLE WITH PVC PIPE AND OF PROPER CONSISTENCY. NO MIXING OF SOLVENT WITH THINNER WILL BE ALLOWED. D. PIPE PRIMER: COMPATIBLE WITH PVC PIPE AND OF PROPER CONSISTENCY. E. CONTROL WIRES: 24 VOLT SOLID WIRE U.L. APPROVED FOR DIRECT BURIAL IN GROUND. BLACK #14 UF DIRECT LEAD AND WHITE #12 UF COMMON GROUND, UNLESS NOTED ON PLANS. F. WIRE CONDUIT UNDER PAVEMENT: ASTM Dl 785 2" PVC PIPE, SCH. 40. G. SPRINKlER HEADS: OF THE MANUFACTURE SPECIFIED IN LEGEND ON DRAWINGS. H. RISERS: SCH. 80 PVC. J. PLASTIC VALVE BOXES: CARSON, AMETEK, OR APPROVED EQUAL. K. CONTROLLER: OF THE MANUFACTURE SPECIFIED IN LEGEND ON DRAWINGS. L. CONTROLLER HOUSING: AS DETAILED IN THESE PLANS, SHEET 1-4. M. REMOTE CONTROL VALVES: OF THE MANUFACTURE SPECIFIED IN LEGEND ON DRAWINGS. N. BACKFLOW PREVENTER (REDUCED PRESSURE TYPE): OF THE MANUFACTURER SPECIFIED IN LEGEND ON DRAWINGS. 0. BRASS PIPE AND FITTINGS: STANDARD WEIGHT, IPS THREADED, CLASS I, 85% RED BRASS. PART 4 -INSTALLATION 4.01 LAYOUT A. LAYOUT WORK AS ACCURATELY AS POSSIBLE TO THE DRAWINGS. THE DRAWINGS, THOUGH CAREFULLY DRAWN, ARE GENERALLY DIAGRAMMATIC TO THE EXTENT THAT SWING JOINTS, OFFSETS AND ALL FITTINGS ARE NOT SHOWN. JOB CONDITIONS WILL NOT ALWAYS PERMIT LOCATING PIPING, VALVES, AND HEADS WHERE SHOWN. WHEN THIS SITUATION OCCURS, IT SHALL BE BROUGHT TO THE LANDSCAPE ARCHITECT'S ATTENTION IMMEDIATELY AND THE RELOCATION DETERMINED IN A JOINT CONFERENCE. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE RELOCATING OF ANY ITEMS WITHOUT FIRST OBTAINING LANDSCAPE ARCHITECT'S APPROVAL. HE SHALL REMOVE AND RELOCATE SUCH ITEMS AT HIS OWN EXPENSE IF SO DIRECTED BY THE LANDSCAPE ARCHITECT. B. MINOR CHANGES IN LOCATIONS TO THE ABOVE FROM LOCATIONS SHOWN SHALL BE MADE WHEN DIRECTED BY LANDSCAPE ARCHITECT AT NO ADDITIONAL COST TO THE OWNER PROVIDING SUCH CHANGE IS ORDERED BEFORE SUCH ITEMS OF WORK, OR WORK DIRECTLY CONNECTED TO SAME ARE INSTALLED, AND PROVIDING NO ADDITIONAL MATERIALS ARE REQUIRED. 4.02 EXCAVATING AND TRENCHING IS A. PRIOR TO EXCAVATION, LOCATE ALL UTILITIES. SEE NOTE AT THE BEGINNING OF THIS SECTIOIN. PERFORM ALL EXCAVATIONS AS REQUIRED FOR THE INSTALLATION OF THE WORK INCLUDED UNDER THIS SECTION, INCLUDING SHORING OF EARTH BANKS TO PREVENT CAVE-INS. RESTORE ALL SURFACES, EXISTING UNDERGROUND INSTALLATIONS, ETC., DAMAGED OR CUT AS A RESULT OF THE EXCAVATIONS, TO THEIR ORIGINAL CONDITION AND IN A MANNER APPROVED BY LANDSCAPE ARCHITECT. 8. ALL TRENCHES SHALL BE A MINIMUM OF 12" FROM SIDEWALKS. C. TRENCHES SHALL BE MADE WIDE ENOUGH TO ALLOW A MINIMUM OF 4" BETWEEN PARALLEL PIPE LINES. NO STACKING OF PIPES VERTICALLY WITH IN THE SAME TRENCH TO BE ALLOWED. TRENCHES FOR PIPE LINES SHALL BE MADE OF SUFFICIENT DEPTHS TO PROVIDE THE MINIMUM COVER FROM FINISH GRADE AS FOLLOWS: 1. 18" MINIMUM COVER OVER MAIN LINES TO REMOTE CONTROL VALVES. 2. 12" MINIMUM COVER OVER LATERAL LINES TO HEADS. 3. 24" MINIMUM COVER UNDER PRIVATE DRIVEWAYS, AND PAVED PARKING AREAS. 4. 30" MINIMUM COVER UNDER PRIVATE STREET. D. MAINTAIN ALL WARNING SIGNS, SHORING, BARRICADES, FLARES, AND RED SIGNAL LANTERNS AS REQUIRED BY THE SAFETY ORDERS OF THE DIVISION OF INDUSTRIAL SAFETY AND ANY LOCAL ORDINANCES. E. SLEEVES SCHEDULE: 1. UNDER A PRIVATE STREET 30" OF COVER, SCH. 80 PVC. 2. UNDER DRIVEWAYS TO A HOME, 24" OF COVER, SCH.40 PVC. 3. LATERALS UNDER WALKWAY TO A HOME, 12" OF COVER SCH. 40 PVC. 4. MAINS AND WIRES UNDER WALKWAYS TO A HOME, 18" OF COVER SCH. 40 PVC. 4.03 PIPE LINE ASSEMBLY A. BACKFLOW PREVENTER: INSTALL 12" MINIMUM ABOVE GRADE WITH CONCRETE THRUST BLOCKS. B. REMOTE CONTROL VALVES: INSTALL WHERE SHOWN. GROUP TOGETHER WHERE PRACTICAL. PLACE NO CLOSER THAN 1 2" AND PARALLEL TO SIDEWALK, AND HOUSE IN VALVE BOXES. SNAKE WIRES BELOW PIPE IN COMMON TRENCH, AT A MINIMUM OF 1" FROM PIPE. PROVIDE A 36" LOOP OF WIRE AT EACH VALVE. BUNDLE WIRE AT 10 FOOT INTERVALS WITH A 12" LOOP OF ELECTRICIAN'S TAPE, ALLOWING FOR EXPANSION. CONTROL WIRE SPLICES SHALL BE ALLOWED ONLY ON RUNS MORE THAN START OF THE MAINTENANCE PERIOD IF REQUIRED BY OWNER. AFTER THE SOIL HAS BEEN PREPARED AS CALLED FOR IN THE SECTION ON SOIL PREPARATION, THE IRRIGATION SYSTEM HAS BEEN INSTALLED AND TESTED, AND CONDITIONS ARE FAVORABLE TO PLANT, THE LANDSCAPE CONTRACTOR SHALL REQUEST APPROVAL TO START PLANTING FROM THE LANDSCAPE ARCHITECT. 500' LONG. CRIMP WIRES TOGETHER WITH STA KON #PT-70 CONNECTOR OR APPROVED 8. CERTIFIED LA BORA TORY TEST REPORTS: SUBMIT FOR APPROVAL, CERTIFIED COPIES OF THE REPORTS OF TESTS LISTED BELOW AND REQUIRED IN REFERENCED PUBLICATIONS FOR THE FOLLOWING MATERIALS: B. PLANTING STOCK: PLANTING STOCK SHALL BE WELL-BRANCHED AND WELL-FORMED, SOUND, VIGOROUS, HEALTHY, AND FREE FROM DISEASE, SUN SCALE, WINDBURN, ABRASION, AND HARMFUL INSECTS OR INSECT EGGS, AND SHALL HAVE HEALTHY, NORMAL, AND UNBROKEN ROOT SYSTEMS AND NOT ROOT BOUND. DECIDUOUS TREES AND SHRUBS SHALL BE SYMMETRICALLY DEVELOPED, OF UNIFORM 1-1ABIT OF GROWTH, WITH STRAIGHT BOLES OR STEMS AND FREE FROM OBJECTIONABLE DISFIGUREMENTS. EVERGREEN TREES AND SHRUBS SHALL HAVE WELL DEVELOPED SYMMETRICAL TOPS WITH TYPICAL SPREAD OF BRANCHES FOR EACH PARTICULAR SPECIES OR VARIETY. GROUND COVERS AND VINES SHALL BE VIGOROUS, HAVE THE NUMBER AND LENGTH OF RUNNERS, AND CLUMP SIZE SPECIFIED, AND BE THE PROPER AGE FOR THE GRADE OF PLANTS SPECIFIED. ONLY VINES AND GROUND COVER PLANTS WELL ESTABLISHED IN REMOVABLE CONTAINERS, INTEGRAL CONTAINERS, OR FORMED HOMOGENEOUS SOIL SECTIONS SHALL BE USED. PLANTS SHALL NOT BE PRUNED PRIOR TO DELIVERY, EXCEPT AS AUTHORIZED BY THE LANDSCAPE ARCHITECT, OR HIS REPRESENTATIVE. IN NO CASE SHALL TREES BE TOPPED BEFORE DELIVERY. c. EQUAL. SEAL CONNECTION WITH APPROVED SEALING COMPOUND. PROVIDE CONDUIT WHERE WIRES RUN UNDER PAVING. PLASTIC PIPE AND FITTINGS: PIPE MAY BE ASSEMBLED AND WELDED ON THE SURFACE. SNAKE PIPE FROM SIDE TO SIDE OF TRENCH BOTTOM TO ALLOW FOR EXPANSION AND CONTRACTION. SOLVENT-WELD PLASTIC PIPE AND FITTINGS, USING SOLVENTS AND METHODS AS RECOMMENDED BY MANUFACTURER OF THE PIPE, EXCEPT WHERE SCREWED CONNECTIONS ARE REQUIRED. PIPE AND FITTINGS SHALL BE 1. AGRICULTURE SUITABILITY SOIL TESTS WILL BE MADE BY THE CONTRACTOR AFTER ROUGH GRADING IS COMPACTED AND CONTRACTOR SHALL ADJUST SOIL AMENDMENTS AND CONTRACT SUM ACCORDINGLY. SUBMIT TEST RESULTS TO CITY INSPECTORS FOR APPROVAL PRIOR TO AMENDING SOIL. THOROUGHLY CLEANED OF DIRT, DUST, AND MOISTURE BEFORE APPLYING SOLVENT. 2.01 DELIVERY C. SIZES OF PLANTS: SHALL BE AS STATED IN THE PLANT LIST. CONTAINER STOCK ( 1 GALLON, 5 GALLON, AND 15 GALLON) SHALL HAVE BEEN GROWN IN CONTAINERS FOR A PERIOD OF TIME SUFFICIENT TO DEVELOP ROOT GROWTH SUFFICIENT TO HOLD THE SOIL BALL TOGETHER TO THE SIDE AND BOTTOM OF THE CONTAINER IN WHICH IT WAS DELIVERED. THE HEIGHT AND SPREAD OF ALL PLANT MATERIAL SHALL BE MEASURED WITH BRANCHES IN THEIR NORMAL POSITION; AND SHALL BE AS INDICATED ON TIHE DRAWINGS. THE CALIPER OF ALL TREES SHALL BE MEASURED Z'-0" ABOVE THE SURFACE OF THE GROUND. WHERE CALIPER OR OTHER DIMENSIONS OF ANY PLANT MATERIALS ARE OMITTED FROM THE "LIST OF PLANT MATERIALS," IT SHALL BE AVERAGE STOCK FOR TYPE LISTED. D. E. INSTALL PIPE AT TEMPERATURES OVER 40 DEGREES F. IMPORTANT' CLEAN OFF EXCESS SOLVENT. ALL WELDED JOINTS SHALL CURE AT LEAST 15 MINUTES BEFORE MOVING OR HANDLING, AND AT LEAST 24 HOURS BEFORE WATER IS PERMITTED IN THE PIPE. PLASTIC TO METAL PIPE CONNECTIONS: MAKE ALL CONNECTIONS BETWEEN PLASTIC PIPE AND MEAL PARTS OR PIPE WITH THREADED FITTINGS USING PLASTIC MALE ADAPTERS. APPLY A NON-HARDENING PIPE DOPE OR TEFLON TAPE TO MALE THREADS. TAKE UP WITH LIGHT WRENCH PRESSURE. SPRINKLER HEADS: SEE DETAILS FOR DISTANCES FROM SIDEWALKS, DRIVEWAYS, OR CURBS. PLACE TOP OF POP-UP HEADS FLUSH WITH FINISH GRADE. ALL RISERS SHALL BE OF SCHEDULE 80 PVC PIPE. F. PLUGGING PIPE: CAP OR PLUG ALL OPENINGS AS SOON AS LINES HAVE BEEN INSTALLED TO PREVENT THE ENTRANCE OF MATERIALS THAT COULD OBSTRUCT THE PIPE, AND LEAVE IN PLACE UNTIL REMOVAL IS NECESSARY FOR COMPLETION OF INSTALLATION. G. FLUSHING IRRIGATION SYSTEM: THOROUGHLY FLUSH OUT ALL WATER LINES, THEN INSTALL HEADS, VALVES, AND OTHER HYDRANTS. TEST IN ACCORDANCE WITH THE FOLLOWING GUIDELINES: 1. REQUEST THE PRESENCE OF LANDSCAPE ARCHITECT AND CITY LANDSCAPE INSPECTOR AT LEAST FORTY-EIGHT (48) HOURS IN ADVANCE OF TESTING. TEST IS TO BE ACCOMPLISHED AT THE EXPENSE OF CONTRACTOR, AND IN THE PRESENCE OF THE LANDSCAPE ARCHITECT AND CITY LANDSCAPE INSTRUCTOR. 2. CENTER LOAD PIPING WITH SUFFICIENT AMOUNT OF BACKFILL TO PREVENT ARCHING OR SLIPPING UNDER PRESSURE. APPLY CONTINUOUS WATER PRESSURE OF THE NUMBER OF POUNDS PER SQUARE INCH SPECIFIED BELOW. (A) PRESSURE LINES TO BE TESTED FOR FOUR HOURS AT 150 P.S.I. (B) LATERAL LINES TO BE TESTED FOR TWO HOURS AT 95 P.S.I. 3. REPAIR LEAKS RESULTING FROM TESTS AND RETEST UNTIL SYSTEM MEETS SPECIFIED TESTS. H. UPON COMPLETION OF THE PRESSURE TESTING, THE CONTRACTOR SHALL COMPLETE ASSEMBLY AND ADJUST SPRINKLER HEADS FOR PROPER DISTRIBUTION. THE CITY LANDSCAPE CONSUL TANT WILL REQUIRE THE CONTRACTOR TO PERFORM A COVERAGE TEST. 4.04 AUTOMATIC CONTROLLER A. INSTALL CONTROLLER AS SHOWN ON THE PLAN, UNLESS OTHERWISE DIRECTED BY THE LANDSCAPE ARCHITECT. CONNECT REMOTE CONTROL VALVES TO CONTROLLER IN A SEQUENCE CORRESPONDING TO VALVE STATION NUMBERS AS SHOWN ON THE PLANS. 8. CONTROLLER CHART: PREPARE A MAP DIAGRAM SHOWING LOCATION OF ALL VALVES, LATERAL LINES, AND ROUTE OF THE CONTROL WIRE. IDENTIFY ALL VALVES AS TO SIZE, STATION, NUMBER, AND TYPE OF PLANTING IRRIGATED, I.E., LAWN, SHRUBS, OR GROUND COVER. SUBMIT DIAGRAM TO LANDSCAPE ARCHITECT FOR APPROVAL, PRIOR TO FINAL INSPECTION. APPLY PLASTIC TAPE CODE TO CONTROLLER LID AS PROVIDED. LAMINATE AND MOUNT NEXT TO CONTROLLER. CONTRACTOR TO ALSO FILL OUT CIRCUIT DIAGRAM WITHIN CONTROLLER BOX. PLANT SPECIFICATIONS PART 1-GENERAL 1.01 SCOPE OF WORK A. WORK DISCUSSED IN THIS SECTION INCLUDES THE FURNISHING OF ALL LABOR, MATERIALS, AND EQUIPMENT REQUIRED TO COMPLETE WORK INDICATED ON THE DRAWINGS. THE WORK SHALL BE PERFORMED IN ACCORDANCE WITIH THE BEST STANDARDS OF PRACTICE RELATING TO THE VARIOUS TRADES AND UNDER THE CONTINUOUS SUPERVISION OF A COMPETENT FOREMAN, CAPABLE OF INTERPRETING THE DRAWINGS, NOTES, AND THESE SPECIFICATIONS. B. IRRIGATION AND LANDSCAPE WORK MAY BE DONE CONCURRENTLY, HOWEVER, LANDSCAPE WORK MAY NOT START IN ANY SECTION PRIOR TO INSPECTION AND APPROVAL OF THE SPRINKLER WORK. C. PRIOR TO EXCAVATION FOR PLANTING OR PLACING OF STAKES, LOCATE ALL ELECTRICAL CABLES, CONDUITS, SPRINKLER VALVES, AND ALL UTILITY LINES SO THAT PROPER PRECAUTIONS MAY BE TAKEN NOT TO DAMAGE SUCH IMPROVEMENTS. IN THE EVENT OF A CONFLICT BETWEEN SUCH LINES AND PLANT LOCATIONS, PROMPTLY NOTIFY THE LANDSCAPE ARCHITECT WHO SHALL ARRANGE FOR RELATION FOR ONE OR THE OTHER. FAILURE TO FOLLOW THIS PROCEDURE PLACES UPON THE CONTRACTOR THE RESPONSIBILITY FOR (AT HIS OWN EXPENSE) MAKING ANY AND ALL REPAIRS FOR DAMAGE RESULTING FROM WORK HEREUNDER. 1.02 SUBMITTALS A. CERTIFICATIONS OF CONFORMANCE OR COMPLIANCE: IN ADDITION m ANY OTHER CERTIFICATES SPECIFIED, THE CONTRACTOR SHALL FURNISH A CERTIFICATE WITH EACH DELIVERY OF BULK MATERIAL STATING THE SOURCE; QUANTITY; TYPE OF MATERIAL; AND THAT THE MATERIAL CONFORMS TO THE SPECIFICATION REQUIREMENT. FOR BULK DELIVERED ORGANIC FERTILIZER, THE CERTIFICATE SHALL ALSO STATE THE VOLUME, NET WEIGHT, PERCENT OF NITROGEN, PERCENT OF PHOSPHORIC ACID, AND THAT SLUDGE IS PROPERLY PROCESSED AND WILL NOT BURN OR OTHERWISE DAMAGE PLANTS, OR PLANT ROOTS. FOR OTHER FERTILIZERS AND SOIL CONDITIONERS IN CONTAINERS, A SIMILAR CERTIFICATE OR INVOICE SHALL BE FURNISHED STATING TOTAL QUANTITIES BY WEIGHTS AND VOLUME FOR EACH MATERIAL. TIHESE CERTIFICATES SHALL BE SUBMITTED TO THE LANDSCAPE ARCHITECT PRIOR TO THE A. PROVIDE NOTIFICATION OF THE DELIVERY SCHEDULE IN ADVANCE SO MATERIAL MAY BE INSPECTED UPON ARRIVAL AT THE JOB SITE. REMOVE UNACCEPTABLE MATERIAL FROM THE JOB SITE IMMEDIATELY. B. PROTECT PLANTS DURING DELIVERY TO PREVENT DAMAGE TO THE ROOT BALLS OR DESICCATION OF LEAVES. PROTECT TREES DURING TRANSPORT BY TYING IN THE BRANCHES AND COVERING ALL EXPOSED BRANCHES. C. DELIVER PESTICIDES AND SOIL FUMIGANTS TO THE SITE IN THE ORIGINAL UNOPENED CONTAINERS. CONTAINERS THAT DO NOT HAVE A LEGIBLE LABEL THAT IDENTIFIES THE ENVIRONMENTAL PROTECTION AGENCY REGISTRATION NUMBER AND THE MANUFACTURER'S REGISTERED USES WILL BE REJECTED. THE HERBICIDE APPLICATOR SHALL BE LICENSED BY THE STATE OF CALIFORNIA. 2.02 STORAGE A. STORE AND PROTECT PLANTS NOT INSTALLED ON THE DAY OF ARRIVAL AT THE SITE AS FOLLOWS: 1. OUTSIDE STORAGE SHALL BE PROTECTED FROM TIHE WIND. 2. KEEP PLANTS, INCLUDING THOSE IN CONTAINERS, IN A MOIST CONDITION BY WATERING WITH FINE MIST SPRAY. 3. SEPARATE PLANTS TO PREVENT "DAMPING OFF." 8. KEEP GYPSUM AND FERTILIZER IN DRY STORAGE AND AWAY FROM CONTAMINANTS. C. DO NOT STORE SOIL STERILANT AND HERBICIDES WITH ANY OTHER LANDSCAPE MATERIALS. STORE IN AN APPROVED, LOCKED, SEPARATE STRUCTURE OR VEHICLE. 2.03 HANDLING A. PLANTS: TAKE CARE TO AVOID DAMAGING PLANTS BEING MOVED FROM THE NURSERY OR STORAGE AREA TO THE PLANTING SITE. HANDLE ALL PLANTS CAREFULLY TO AVDID CRACKING OR BREAKING THE ROOT BALL. DO NOT HANDLE PLANTS BY THE TRUNK OR STEM. REMOVE DAMAGED PLANTS OR PLANTS WITH BROKEN OR CRACKED ROOT BALLS FROM THE SITE. B. SPECIMEN PLANTS SHALL BE PLANTED, MULCHED, GUYED, AND IN A BASIN AND FERTILIZED WITHIN 48 HOURS AFTER REMOVAL FROM PREVIOUS LOCATION. 2.04 JOB CONDITIONS A. PLANTING CONDITIONS: PLANTING SHALL NOT BE DONE WHEN THE GROUND IS MUDDY OR IN AN UNSATISFACTORY CONDITION FOR PLANTING. 2.05 GUARANTEE A. WORK SHALL BE SUBJECT TO THE TERMS OF THE CLAUSE ENTITLED "WARRANTY OF CONSTRUCTION" OF THE GENERAL PROVISIONS, EXCEPT THAT PLANT MATERIAL SHALL BE GUARANTEED THROUGH THE PLANT MAINTENANCE PERIOD (SEE 5.03). ALL PLANTINGS SHALL BE GUARANTEED FOR AS LONG AS THE CONTRACTOR IS MAINTAINING THE LANDSCAPING, WITH THE EXCEPTION THAT BOXED TREES SHALL BE GUARANTEED FOR ONE YEAR. ANY MATERIAL THAT IS NOT GROWING PROPERLY DURING THIS PERIOD SHALL BE REPLACED BY THE LANDSCAPE CONTRACTOR WITHIN SEVEN (7) DAYS AFTER RECEIPT OF A WRITTEN NOTICE BY THE LANDSCAPE ARCHITECT. ALL PLANT MATERIALS SHALL BE GUARANTEED FOR THE ORIGINAL PERIOD, STARTING FROM THE DATE OF REPLACEMENT. THE CONTRACTOR'S GUARANTEE MAY BE EXTENDED BY THE LANDSCAPE ARCHITECT IN CASES WHERE PLANTS ARE SLOW TO ESTABLISH. IF THE CONTRACTOR FAILS TO MAKE REPLACEMENTS WITHIN THE TIME LIMIT, THE OWNER MAY REPLACE THEM AT THE CONTRACTOR'S EXPENSE AFTER DULY NOTIFYING HIM. PART 3 -PRODUCTS 3.01 PLANTS A. PLANT MATERIAL SHALL BE FURNISHED IN THE QUANTITIES AND/OR SPACING AS SHOWN, OR NOTED FOR EACH LOCATION, AND SHALL BE OF THE SPECIES, KINDS, SIZES, ETC., AS SYMBOLIZED AND/OR DESCRIBED IN THE "LIST OF PLANT MATERIALS" AS INDICATED ON THE DRAWINGS. PLANT NAMES INDICATED OR LISTED IN THE "LIST OF PLANT MATERIALS" ON THE DRAWINGS CONFORM TO "STANDARD PLANT NAMES" ESTABLISHED BY THE AMERICAN JOINT COMMITTEE ON HORTICULTURAL NOMENCLATURE, EXCEPT FOR NAMES NOT COVERED HEREIN, THE ESTABLISHED CUSTOM OF THE NURSERY IS FOLLOWED. D. PLANT MATERIAL: PLANT MATERIAL SHALL BE NURSERY GROWN, UNLESS OTHERWISE INDICATED. 1. GROUND COVER PLANTS SHALL BE WELL ROOTED CUTTINGS GROWN IN FLATS AND SHALL REMAIN IN THOSE FLATS UNTIL PLANTED. E. SUBSTITUTIONS: SUBSTITUTIONS FOR THE INDICATED PLANT MATERIALS WILL BE PERMITTED, PROVIDED THE SUBSTITUTE MATERIALS ARE APPROVED IN ADVANCE BY THE LANDSCAPE ARCHITECT, AND THE SUBSTITUTIONS ARE MADE AT NO ADDITIONAL CHARGE TO THE OWNER. EXCEPT FOR THE VARIATIONS SO AUTHORIZED, ALL SUBSTITUTE PLANT MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THESE SPECIFICATIONS. IF ACCEPTED SUBSTITUTE MATERIALS ARE OF LESS VALUE THAN THOSE INDICATED OR SPECIFIED, THE CONTRACT PRICE WILL BE ADJUSTED IN ACCORDANCE WITH THE PROVISIONS OF THE CONTRACT. F. APPROVAL: ALL PLANT MATERIALS SHALL BE SUBJECT TO THE INSPECTION AND APPROVAL OF THE LANDSCAPE ARCHITECT, OR HIS REPRESENTATIVE, BEFORE PLANTING. CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT OF EACH PLANT MATERIAL DELIVERY. ALL PLANTS SUPPLIED TO THE PROJECT (WHETHER PLANTED OR NOT) ARE SUBJECT TO REJECTION BY THE LANDSCAPE ARCHITECT. PLANTS NOT APPROVED SHALL BE REMOVED FROM SITE IMMEDIATELY AND REPLACED WITH SUITABLE PLANTS. THE LANDSCAPE ARCHITECT MAY REJECT ENTIRE LOT OF PLANTS REPRESENTED BY DEFECTIVE SAMPLES. 3 .02 SEED AND SOD A. SOD FOR LAWNS: SOD SHALL BE INDICATED ON THE PLANS. THE SOURCE OF THE SOD SHALL BE SUBJECT TO APPROVAL OF THE LANDSCAPE ARCHITECT. THE LANDSCAPE CONTRACTOR SHALL TAKE PRECAUTIONS IN THE HANDLING AND TEMPORARY STORAGE OF THE SOD. ~ -·, , , .. -fHW;j '"' daedalus design group landscape architecture : construction 2725 jcffcn,;on street, suite 15b earl shad, rnllfornla 92008 r>ho11e 760/ 720-9337 APPROVED FOR PLANTING "AS BUILT" AND IRRIGATION ONLY, PL O"T" n t\:rE · Fs r·, 0105 "~ ,,, ~ ~4 l" .. ,~"'' ~ ,;_ """""l INCLUDING PRECISE TITLE DATE ENGINEER'S SIGNATURE REQUIRED ON PAGE 1 ONLY LOCATION OF PLANTING REVIEWED BY: REVIEWED AREAS. .. ENGINEERING PLANCHECKER DATE INSPECTOR DATE I SH;ET I CITY OF CARLSBAD JI SHEETS I PLANNING DEPARTMENT 10 _,_. -- LA SUVERA FISHERMAN DRIVE --·-., ·---·--CARLSBAD, CA. 92008 PLANTING AND IRRIGATION SPECIFICATIONS APPROVED ~ -·-··------· 9--11-oS" ll . ASSISTANT PLANNING DIRECTOR DATE INITIAL _,, ---, OWN BY: PROJECT NO. DRAWING ND. DATE REVISION DESCRIPTION DATE INITIAL DATE INITIAL ! CHKD BY: ENGINEER OF WORK ! RVWD BY: CDP 04-16 4272L OTHER APPROVAL CITY APPROVAL PLANT SPECIFICATIONS (CONT.) 3.03 TOPSOIL A. WHERE NEW TOPSOIL IS CALLED FOR, PROVIDE NEW TOPSOIL AND/OR MODIFY EXISTING TOPSOIL TO SUPPLY THE FOLLOWING COMPOSITION REQUIREMENTS: PH BETWEEN 6 AND 7.6, CONTAINING FROM 5 TO 20 PERCENT ORGANIC MATTER AS DETERMINED BY THE ORGANIC CARBON 6A, CHEMICAL ANALYSIS METHOD DESCRIBED IN USDA SOIL SURVEY INVESTIGATION REPORT NO. 1. MAXIMUM PARTICLE SIZE, 3/4- INCH, WITH MAXIMUM 3 PERCENT RETAINED ON 1/4-INCH SCREEN. SOLUBLE SALTS SHALL NOT EXCEED 600 PPM. OTHER COMPONENTS SHALL BE WITHIN THE FOLLOWING PERCENTAGES: SILT 25-50 CLAY 10-30 SAND 20-35 3.04 PH ADJUSTERS: A. GYPSUM: COMMERCIALLY PACKAGED, FREE FLOWING GYPSUM CONTAINING NOT LESS THAN 95 PERCENT, BY VOLUME, OF CALCIUM SULPHATE AS ACTIVE INGREDIENT. 3.03 TOPSOIL A. WHERE NEW TOPSOIL IS CALLED FOR, PROVIDE NEW TOPSOIL AND/OR MODIFY EXISTING TOPSOIL TO SUPPLY THE FOLLOWING COMPOSITION REQUIREMENTS: PH BETWEEN 6 AND 7.6, CONTAINING FROM 5 TO 20 PERCENT ORGANIC MATTER AS DETERMINED BY THE ORGANIC CARBON 6A, CHEMICAL ANALYSIS METHOD DESCRIBED IN USDA SOIL SURVEY INVESTIGATION REPORT NO. 1. MAXIMUM PARTICLE SIZE, 3/4-INCH, WITH MAXIMUM 3 PERCENT RETAINED ON 1/4-INCH SCREEN. SOLUBLE SALTS SHALL NOT EXCEED 600 PPM. OTHER COMPONENTS SHALL BE WITHIN THE FOLLOWING PERCENTAGES: SILT 25-50 CLAY 10-30 SAND 20-35 3.04 PH ADJUSTERS: A. GYPSUM: COMMERCIALLY PACKAGED, FREE FLOWING GYPSUM CONTAINING NOT LESS THAN 95 PERCENT, BY VOLUME, OF CALCIUM SULPHATE AS ACTIVE INGREDIENT, 3.05 SOIL CONDITIONERS USE INDIVIDUALLY OR IN COMBINATION AS REQUIRED TO MEET SPECIFIED REQUIREMENTS FOR TOPSOIL. A. PEAT: SPHAGNUM MOSS PEAT, HYPNUM MOSS PEAT, REED-SEDGE PEAT, AND PEAT HUMUS, EXCEPT AS OTHERWISE SPECIFIED HEREIN. PEAT SHALL BE DERIVED FROM A FRESHWATER SITE, SHREDDED AND GRANULATED TO PASS A 1/2-INCH MESH SCREEN AND CONDITIONED IN STORAGE PIILES FOR AT LEAST SIX MONTHS PRIOR TO USE. B. MANURE: COMMERCIALIL Y STERILIZED AND SACKED STEER MANURE CONTAINING MAXIMUM 25 PERCENT BY VOLUME OF STRAW, SAWDUST, OTHER BEDDING MATERIALS FREE OF STONES, STICKS, SOIL, AIND TOXIC MATERIALS HARMFUL TO PLANTS; WELL COMPOSTED AND SCREENED TO PASS THROUGH A 1 / 4-INCH SIEVE. C. NITROLIZED WOOD DERIVATIVES: GROUND BARK, SAWDUST, OR OTHER WOOD WASTE MATERIAL FREE OF STONES, STICKS, AND TOXIC SUBSTANCES HARMFUL TO PLANTS, STABILIZED WITH NITROGEN AND HAVING THE FOLLOWING PROPERTIES: PARTICLE SIZE: MINIMUM PERCENT BY WEIGHT PASSING: NO. 4 MESH SCREEN 9 5 NO. 8 MESH SCREEN 80 NITROGEN CONTENT: MINIMUM PERCENT BASED ON DRY WEIGHT: REDWOOD SAWDUST 0.5 FIR SAWDUST 0.7 FIR OR PINE BARK 1.0 D. COMPOSED ORGANIC WASTE: CHEMICALLY TREATED AND COMPOSTED ORGANIC WASTES SUCH AS RICE HULLS, SPENT COFFEE BEANS, SLUDGE, PEAT AND WOOD WASTES. E. FERTILIZER AND SOIL CONDITIONER: ORGANIC MATERIALS (EXCLUDING HUMAN WASTES) CONTAINING THE FOLLOWING MINIMUM PERCENTAGES, BY WEIGHT, BY PLANT FOOD NUTRIENTS, AND HUMUS. 3.06 FERTILIZER 5% NITROGEN 3% PHOSPHATE 1% POTASH 50% HUMUS 1 5% HUMIC ACIDS A. FERTILIZER FOR SOIL PREPARATION AND PLANTING BACKFILL: GROW POWER PLUS, GRANULAR FERTILIZER CONTAINING THE FOLLOWING MINIMUM PERCENTAGES, BY WEIGHT, OF PLANT FOOD NUTRIENTS: 5.0% AVAILABLE NITROGEN 3.0% AVAILABLE PHOSPHOROUS 1.0% AVAILABLE POTASSIUM 0% SULFUR 1.0% IRON B. FERTILIZER FOR LAWN AND GROUND COVER MAINTENANCE: BEST TURF SUPREME, CONTAINING THE FOLLOWING MINIMUM PERCENTAGES, BY WEIGHT, OF PLANT FOOD NUTRIENTS: 16.0% AVAILABLE NITROGEN 6% AVAILABLE PHOSPHOROUS 8% AVAILABLE POTASSIUM 16% SULFUR 1.5% IRON C. FERTILIZER PLANTING TABLETS: YIGHTL Y COMPRESSED FERTILIZER CHIPS FORMING A TABLET THAT IS iNSOLUBLE IN WATER, IS DESIGNED TO PROVIDE A CONTINUOUS RELEASE OF NUTRIENTS FOR AT LEAST 24 MONTHS AND CONTAINS THE FOLLOWING MINIMUM PERCENTAGES, BY WEIGHT, OF PLANT FOOD NUTRIENTS: 20% AVAILABLE NITROGEN 1 0% AVAILABLE PHOSPHORUS 5% AVAILABLE POTASSIUM PLANTING TABLETS SHALL WEIGH APPROX I MA TEL Y 21 GRAMS EACH FOR TREES AND SHRUBS AND 5 GRAMS EACH FOR GROUND COVER PLANTS. D. IRON CHELATES: CONTAINING 1 0 PERCENT IRON AS METALILIC. 3.07 MULCH SHALL BE 3" LAYER OF GROUND & SHREDDED FIR BARK (0-1 /2" IN SIZE). SAMPLE TO BE INSPECTED FOR APPROVAL BY CITY INSPECTOR, 3.08 LIGHTWEIGHT SOIL FOR PLANTERS A SOIL MIXTURE OF THE FOLLOWING COMPOSITION SHALL BE USED FOR IMPORT SOIL TO FILL RAISED PLANTERS AND POTS. SOIL SHALL BE PREMIXED BY MACHINE BLENDER PRIOR TO DELIVERY TO SITE: 9 PARTS BY VOLUME -LOAMEX OR EQUAL 1 PART BY VOLUME WASHED PLASTER SAND 2 CU. FT. PER CU. YD. OR MIX PERLITE 10 POUNDS PER CU. YD. OF MIX MICRO-MAX. PLUS OR EQUAL (MICRO-NUTRIENT COMPLEX) 10 POUNDS PER CU. YDS. OF MIX 18-6-8 FERTILIZER 1, LOAMEX IS A BLEND OF ORGANIC FRACTION TO SUPPLY SEVERAL BREAKDOWN RATES AND A PORTION OF INORGANIC AMENDMENTS THAT RESIST FURTHER BREAKDOWN. 2. THE MIX SHALL ALSO CONTAIN A LONG LASTING FORM OF IRON (G.U.49) AND A NON-IONIX WETTING AGENT, AVAILABLE FROM BUTLER'S MILL, INC., LOCATED IN SAN DIEGO. 3.09 TREE STAKING AND GUYING MATERIAL A. STAKES: SHALL BE 1 O' LODGEPOLE STAKES POINTED ON ONE END. B. TREE TIES: SHALL BE CINCH TIE OR APPROVED EQUAL. C. ANCHORS: SHALL BE DUCKBILL (TM) PRODUCT OF APPROPRIATE SIZE AS RECOMMENDED BY MANUFACTURER (FORESIGHT INDUSTRIES, INC., P.O. BOX 4067K CHEYENNE, WY 82003). D. GUYING WIRE: SHALL BE #9 ZINC-COATED WIRE. E. HOSE CHAFING GUARDS: SHALL BE 2-PL Y REINFORCED RUBBER OR PLASTIC HOSE, 1 /2" OR 3/4" DIAMETER, TO COVER WIRE A'T ALL POINTS OF CONTACT WITH TREE. F. TURNBUCKLES: AS REQUIRED, GALVANIZED 3" MINIMUM LENGTHWISE DIMENSION. 3. 10 PESTICIDES AND CHEMICAL CONTROLS SHALL BE USED IN THEIR APPROPRIATE APPLICATIONS WITH STRICT ADHERENCE TO MANUFACTURER'S SPECIFICATIONS & INSTRUCTIONS. A. BROADLEAF WEED CONTROL SHALL BE WEED B. GONE, OR OTHER 2-4-D BASED PRODUCTS. B. PRE-EMERGENCE APPLICATIONS: EPTAM, TREFLAN, SURFLAN OR RONSTAR. C. POST-EMERGENCE APPLICATION: ROUNDUP. D. INSECT CONTROL SHALIL BE SPECTRACIDE, MALATHION-SO, DIAZINON OR AS DEEMED APPROPRIATE BY THE LANDSCAPE ARCHITECT. E. FUNGUS CONTROL SHALIL BE DACONIL OR BORDOIL F, ALTERNATIVE PRODUCTS MAY BE USED IF APPROVED IN WRITING BY THE LANDSCAPE ARCHITECT. 3.11 PLANTING SOIL MIXTURE MIXTURE SHALL BE THOROUGHLY MIXED TO THE PROPORTIONS GIVEN ON THE PLANS. PART 4 -EXECUTION 4.01 PREPARATION OF PLANTING BEDS A. AFTER ALL TRENCHES IN PLANTING AREAS HAVE BEEN SOAKED AND COMPACTED, AND ALL AREAS WITH SLOPES OF LESS THAN 4:1 HAVE BEEN ROUGH GRADED, THESE AREAS SHA.LIL BE CROSS-RIPPED, TILLED AND AMENDED, PER SOILS REPORT, TO A DEPTH OF 6". REMOVE STONES AND DEBRIS LARGER THAN 2-1 /2 INCHES IN DIAMETER. B, TURF AREAS: ALL AREAS TO BE PLANTED WITH TURF SHALL BE THOROUGHLY TILLED AND AMENDED, PER PLANS, TO MINIMUM DEPTH OF 6" BY SCARIFYING, DISKING, HARROWING, AND OTHER APPROVED METHODS. REMOVE DEBRIS AND STONES LARGER THAN ONE INCH IN ANY DIMENSION REMAINING ON SURFACE AFTER TILLAGE. AOD AND TILL IN ALL SOIL AMENDMENTS, AS CALLED FOR IN PLANS, TO A DEPTH OF 6". C. SLOPES: THE LANDSCAPE CONTRACTOR WILL RECEIVE ALL SLOPES AT FINISH GRADE. ALL SLOPES SHALL BE INSPECTED BY THE LANDSCAPE ARCHITECT PRIOR TO HYDROSEEDING TO INSURE THAT THEY ARE FREE OF EROSION, GULLIES, WEEDS, OR OTHER DELETERIOUS MATERIALS TO PROVIDE A SEED BED TYPICAL TO GRADED SLOPES IN THAT REGION, SLOPES SHALL NOT BE DISTURBED IN A MANNER WHICH CHANGES THE SOIL COMPACTION ESTABLISHED BY THE SOIL ENGINEERS. IN PARTICULAR, SLOPES SHALL NOT BE MADE MORE PERMEABLE TO WATER, THUS CREATING AN UNSTABLE SURFACE AREA. D. SOIL TREATMENT: APPLY THE FOLLOWING SOIL TREATMENTS TO THE AREAS LISTED BELOW FOR EACH TREATMENT. FOR APPLICATION, SEE PARAGRAPH "APPLICATION OF PESTICIDES" IN THIS SPECIFICATION. 1. SELECTIVE-COMBINATION WEED CONTROL: 6 WEEKS RESIDUAL (MAXIMUM). PRE-EMERGENCE CONTROL -ALL PLANTED AREAS, EXCEPT SEEDED AREAS, TWICE, ONCE 14 DAYS MINIMUM AFTER GROUND COVER IS PLANTED, AND ONCE AT END OF MAINTENANCE PERIOD. 2. POST-EMERGENCE CONTROL -ALL PLANTED AREAS -AT ALL TIMES AS REQUIRED. 3, PEST AND DISEASE CONTROL -AT ALL TIMES AS REQUIRED. 4.02 FINAL GRADING A. AFTER COMPLETION OF ALL SOIL CONDITIONING, TILLING AND SOIL TREATING, CORRECT IRREGULARITIES IN FINISHED SURFACES TO ELIMINATE DEPRESSIONS. REMOVE ALL DEBRIS AND STONES LARGER THAN ONE INCH REMAINING ON THE SURFACE. PROTECT FINISHED AREAS FROM DAMAGE DUE TO VEHICULAR OR PEDESTRIAN TRAFFIC. B. DEEP WATERING AND LEACHING: AFTER SOIL CONDITIONING AND FINAL GRADING IS COMPLETE, COMPACT AND LEACH PLANTING AREAS BY HEAVY WATERING TO A MINIMUM DEPTH OF 12 INCHES. 4.03 SEEDING AND SODDING A. SODDING: SODDING SHALL BE DONE IN ACCORDANCE WITH APSA GUIDELINES SPECIFICATIONS FOR SODDING. SOD SHALL BE LAID WITHIN 36 HOURS OF THE TIME IT WAS CUT AT THE SOD FARM. NO SOD SHALL BE LAID THAT HAS DRIED OUT OR BEEN DAMAGED. LAY SOD WITH AL TERNA TE JOINTS IN A MANNER THAT INSURES AN EVEN, SMOOTH SURFACE ON A PREPARED SOD BED THAT IS NEITHER EXCESSIVELY DRY NOR WET. LONG SIDES OF SOD PIECES SHALL BE AT RIGHT ANGLES TO SLOPES OR FLOW OF WATER. ON MOUNDS OR SLOPED AREAS, SOD SHALL BE ROLLED WITH AN ALMOST EMPTY ROLLER DRUM, AND LIGHTLY TOP DRESSED AT THE SEAMS, IF REQUIRED TO PRODUCE A SMOOTH FINISH. IMMEDIATELY AFTER ROLLING, SOD SHALL BE WATERED AT A RATE SUFFICIENT TO INSURE THOROUGH WETTING OF THE SOIL TO A DEPTH OF AT LEAST FOUR INCHES. ONCE SOD HAS ROOTED, CONTRACTOR SHALL TAKE CARE TO CUT BACK ON THE WATERING, TO PREVENT THE GROWTH OF FUNGUS. SOD THAT FAILS TO STAY GREEN AND HEAL THY SHALL BE REPLACED BY THE CONTRACTOR AT HIS OWN EXPENSE. 4.04 PLANTING TREES, SHRUBS, GROUND COVERS, AND VINES A. EXCAVATION FOR PLANTING: PRIOR TO EXCAVATING FOR PLANT PITS, THE AREA SHALL CONFORM TO THE LINES AND GRADES SHOWN. VERIFY LOCATION OF UNDERGROUND UTILITIES, REPAIR ANY DAMAGE DONE TO UTILITY LINES SHOWN. IF UTILITY LINES NOT SHOWN ON THE DRAWINGS ARE ENCOUNTERED, NOTIFY THE CONTRACTING OFFICER IMMEDIATELY. IN THE EVENT THAT UNDERGROUND CONSTRUCTION WORK OR OBSTRUCTIONS ARE ENCOUNTERED IN THE PLANTING OPERATION, ALTERNATE LOCATIONS WILL BE DONE AT NO EXTRA COST TO THE OWNER. 1 . PLANT PITS: DIG PITS BY ANY METHOD PROVIDED THAT THE PITS HAVE VERTICAL SIDES AND FLAT BOTTOMS. WHEN PITS ARE DUG WITH AN AUGER AND THE SIDES OF THE PITS BECOME GLAZED, SCARIFY THE GLAZED SURFACE, THE MINIMUM ALLOWABLE DIMENSIONS OF PLANT PITS SHALL BE AS SHOWN IN DETAILS. IF THE PERCOLATION IS SUCH THAT WATER WILL NOT DRAIN OUT OF THE HOLE OVERNIGHT THE CONTRACTOR SHALL TAKE CAUTION NOT TO OVER WATER PLANTS. NO TREES 1 5 GALLONS AND OVER SHALL BE PLANTED IN A HOLE THAT WILL NOT NATURALLY DRAIN OVERNIGHT AFTER HAVING BEEN HALF-FILLED WITH WATER. TESTS SHALL BE CONDUCTED TO MAKE THIS DETERMINATION AND THE LANDSCAPE ARCHITECT NOTIFIED OF THIS CONDITION PRIOR TO PLANTING. 2. SUBSOIL DRAINAGE FOR PLANT PITS AND BEDS: PROVIDE AS INDICATED. LAY PERFORATED DRAIN PIPE WITH PERFORATIONS DOWN, B. ALL PLANTS SHALL BE SET SO THAT, WHEN SETTLED, THEY BEAR THE SAME RELATION TO THE REQUIRED GRADE AS THEY BORE TO THE NATURAL GRADE BEFORE BEING TRANSPLANTED. EACH PLANT SHALL BE PLANTED IN THE CENTER OF THE PIT AND BACKFILL, UNLESS OTHERWISE SPECIFIED, WITH THE PREPARED SOIL. NO SOIL WILL BE PERMITTED AROUND TRUNKS OR STEMS. ALL BROKEN OR FRAYED ROOTS SHALL BE PROPERLY CUT OFF. USE EXCESS TOPSOIL TO FORM WATERING BASINS AROUND PLANTS. AMEND AS DESCRIBED IN NOTES AND DETAILS. 1. WATER THOROIJGHLY WITH A SOLUTION OF VITAMIN B-1 AND WATER PER MANUFACTURER'S SPECIFICATIONS. 2. GROUND COVERS AND VINES: DO NOT REMOVE FROM FLATS AND CONTAINERS UNTIL IMMEDIATELY BEFORE PLANTING. SPACE AT THE INTERVALS INDICATED, SUFFICIENTLY DEEP TO COVER ALL ROOTS. AFTER PLANTING 1 00 PLANTS, IMMEDIATELY SPRINKLE WITH A SOLUTION OF VITAMIN B-1 AND WATER, PER MANUFACTURER'S SPECIFICATIONS, UNTIL ENTIRE AREA IS SOAKED. SMOOTH PLANTING AREAS AFTER PLANTING TO PROVIDE EVEN, SMOOTH FINISH. C. STAKING AND GUYING: 1. STAKING: STAKE ALLS GALLON THRU 24" BOX TREES WITH TWO STAKES, DO NOT INJURE THE BALL OR ROOTS. 2. GUYING: GUY BOXED TREES WITH 3 GUYS EVENLY SPACED AROUND EACH TREE AS SHOWN IN DETAILS. D. MULCHING: WHEN PLANTING OPERATIONS ARE COMPLETE AND SHRUB AREAS HAVE BEEN RAKED AND DRESSED, MULCH ALL SHRUB AND GROUND COVER AREAS WITH A 3" LAYER OF GROUND FIR BARK (O -1 / 4" SIZE). NOTE: MULCH FLATTED GROUND COVER AREAS PRIOR TO PLANTING GROUND COVER. SUBMIT SAMPLE TO CITY INSPECTOR FOR APPROVAL PRIOR TO BULK DELIVERY TO JOB SITE. E. APPLICATION OF PESTICIDES (INC. HERBICIDES & FUNGICIDES): APPLY ALL HERBICIDES AND OTHER CHEMICALS IN ACCORDANCE WITH EPA LABEL RESTRICTIONS AND RECOMMENDATIONS AND FEDERAL AND STATE LAWS. MAKE DAILY REPORTS TO THE CONTRACTING OFFICER STATING AREAS TO BE TREATED WITH EACH CHEMICAL, THE QUANTITY APPLIED AND SPRAY MIXTURE OF FORMULATION USED. APPLICATION AT EACH SITE SHALL BE UNDER THE SUPERVISION OF A CERTIFIED APPLICATOR LICENSED BY THE STATE OF CALIFORNIA, PART 5 -COMPLETION OF CONTRACT 5.01 RESTORATION AND CLEAN-UP A. REMOVE EXCESS WASTE MATERIAL DAILY. WHEN PLANTING IN AN AREA IS COMPLETE, CLEAR THE AREA OF DEBRIS, SPOIL PILES, AND CONTAINERS. WHERE EXISTING TURF AREAS OR PLANTING BEDS HAVE BEEN SCARRED OR DAMAGED, RESTORE THESE DAMAGED AREAS TO THEIR ORIGINAL CONDITION. KEEP AT LEAST ONE PAVED PEDESTRIAN ROUTE TO EACH BUILDING CLEAN AT ALL TIMES. REMOVE DISUSED EQUIPMENT AND IMPLEMENTS OF SERVICE AND LEAVE ENTIRE AREA INVOLVED IN A NEAT ACCEPTABLE CONDITION SUCH AS TO MEET THE APPROVAL OF THE LANDSCAPE ARCHITECT. 5.02 INSPECTIONS A. THE LANDSCAPE ARCHITECT SHALL MAKE PERIODIC INSPECTIONS DURING THE PLANTING. ANY PLANTS THAT HAVE NOT BEEN HANDLED, SPOTTED OR PLANTED PROPERLY SHALL BE SUBJECT TO REMOVAL BY THE LANDSCAPE ARCHITECT OR HIS REPRESENTATIVE, AND THEY SHALL, IF NECESSARY, BE RELOCATED AS DIRECTED AS PART OF THE CONTRACT. 5.03 MAINTENANCE PERIOD A. DEFINITION: THE MAINTENANCE PERIOD SHALL BEGIN ON THE DATE THAT THE OWNER OR DULY APPOINTED REPRESENTATIVE INSPECTS AND GIVES WRITTEN PROVISIONAL ACCEPTANCE OF THE WORK AND SHALIL CONTINUE FOR 90 DAYS FROM THAT DATE. THE DATE FOR ACCEPTANCE OF BOXED TREES SHALIL BE SET AT 12 MONTHS FROM THAT DATE. B. MAINTENANCE: MAINTAIN ALL PLANTING AREAS IN A VIGOROUS, THRIVING CONDITION BY WATERING, CULTIVATING, SPRAYING, WASHING OFF WALKS, AND ANY OTHER NECESSARY OPERATIONS DURING THE ENTIRE PERIOD OF THE INSTALLATION AND UNTIL FINAL ACCEPTANCE BY THE LANDSCAPE ARCHITECT. C. CONTRACTOR SHALL CONTINUOUSLY MAINTAIN ALL AREAS INCLUDED IN THE CONTRACT DURING THE PROGRESS OF THE WORK, THROUGH THE ESTABLISHMENT PERIOD, AND UNTIL FINAL ACCEPTANCE OF THE WORK, D. THE ENTIRE PROJECT SHALL BE SATISFACTORILY MAINTAINED FOR A PERIOD OF NINETY CALENDAR DAYS, COMMENCING FROM THE TIME ALL ITEMS OF IRRIGATION AND LANDSCAPE PLANTING WORK HAVE BEEN COMPLETED AS SPECIFIED IN THE FOREGOING ARTICLES OF THESE SPECIAL PROVISIONS AND TO THE SATISFACTION OF THE OWNER. E. ESTABLISHMENT WORK INCLUDES ALL MOWING, WATERING, WEEDING, RESEEDING, MULCHING, CULTIVATING, SPRAYING, AND TRIMMING NECESSARY TO BRING THE PLANTED AREAS TO A HEAL THY GROWING CONDITION, AND ANY ADDITIONAL WORK NEEDED TO KEEP THE AREAS NEAT, EDGED, AND ATTRACTIVE. F. WATER GRASS UNTIL ACCEPTANCE OF WORK. THE AREAS SHALL BE KEPT MOIST, BUT NOT GLISTENING WET, UNTIL TIME FOR THE FIRST CUTTING OF GRASS. AFTER FIRST CUTTING, WATER LAWN TO MAINTAIN A THRIVING CONDITION. RESEEDED AREAS THAT DO NOT SHOW PROMPT GERMINATION SHALL AGAIN BE RESEEDED AT TEN DAY INTERVALS. THE CONTRACTOR SHALIL MAINTAIN THE LAWN AREAS UNTIL AN EVEN, CLOSE STAND OF GRASS HAS BEEN OBTAINED AND FOR AT LEAST THIRTY DAYS. G. DURING THE PLANT ESTABLISHMENT PERIOD, ALL PLANTS AND PLANTED AREAS SHALL BE KEPT WEED-FREE AT ALL TIMES, WEEDS, DALLAS AND JOHNSON GRASS, AND BERMUDA GRASS SHALL BE REMOVED AND DISPOSED OF. PAY SPECIAL ATTENTION TO WATERING SLOPES PLANTED IN LAWN ON THE WINDWARD AND/OR SUNNY SIDE SO THAT LAWN WILL BE ADEQUATELY WATERED AT ALL TIMES, H. THE LAWNS SHOULD BE EDGED WHENEVER NECESSARY. THE GRASS SHALL BE MOWED WITH SHARP AND ADJUSTED MOWERS BEFORE IT EXCEEDS 2" IN HEIGHT. THE GRASS WILL BE CUT TO NOT LESS THAN 1-1 /2", AND DURING THE PERIOD OF MAINTENANCE, THE GRASS WILL NOT BE ALLOWED TO EXCEED 2" IN HEIGHT. I. IMMEDIATELY AFTER THE FIRST CUTTING OF GRASS, WHEREVER A LAWN AREA IS BOUNDED BY TREES OR SHRUBS, THE EDGE OF THE GRASS SHALL BE TRIMMED TO A NEAT AND UNIFORM LINE AT A DISTANCE OF APPROXIMATELY 2" FROM THE TREES OR SHRUBS, WHERE HEADER EXISTS, TRIM TO HEADER. WHERE TREES OR SHRUBS OCCUR IN GRASS AREAS, THE GRASS SHALL BE TURNED UNDER AND NEATLY EDGED 18" AWAY FROM THE PLANTS. THE LAWN EDGES SHALL BE MAINTAINED IN A NEAT CONDITION UNTIL ACCEPTANCE OF THE WORK. KEEP GRASS 2" AWAY FROM BASE OF TREE. DO NOT USE WEEDEATERS TO TRIM GRASS ADJACENT TO TREE. J. WORKMEN SHALL NOT BE ALLOWED TO WALK ON GRASS AREAS UNNECESSARILY BEFORE, DURING, OR AFTER SEEDING OPERATIONS. GRASS AREAS THAT HAVE BEEN DAMAGED OR COMPACTED SHALL BE RECULTIVATED AND RESEEDED AT THE CONTRACTOR'S EXPENSE. K, ANY DAY THE CONTRACTOR FAILS TO ADEQUATELY WATER, REPLACE UNSUITABLE PLANTS, WEED, AND OTHER WORK DETERMINED TO BE NECESSARY BY THE ARCHITECT, WILL NOT BE CREDITED AS PART OF THE ESTABLISHMENT PERIOD. L. DURING THE ESTABLISHMENT PERIOD, ANY PLANT INDICATING WEAKNESS OR PROBABILITY OF DYING, SHALL BE REPLACED BY THE CONTRACTOR AT HIS OWN EXPENSE. M. ALL BASINS AROUND SHRUBS AND TREES SHALL BE MAINTAINED AT A FOUR INCH DEPTH THROUGHOUT ESTABLISHMENT PERIOD, UNLESS OTHERWISE INSTRUCTED BY THE OWNER OR HIS REPRESENTATIVE, N, TREE STAKES WHICH FOR ANY REASON ARE DAMAGED OR RENDERED INADEQUATE FOR SUPPORT SHALL BE REPAIRED AND RESTORED TO THEIR ORIGINAL CONDITION. 0. CONSTANT DILIGENCE SHALL BE MAINTAINED TO DETECT THE PRESENCE OF DISEASE, INSECTS, AND/OR RODENT INFESTATIONS AND PROPER PREVENTATIVE OR CONTROL MEASURES TAKEN. P. ALL SHRUBS AND TREES SHALL BE MAINTAINED IN THEIR NATURAL SHAPES. TALIL OR SCRAGGLY BRANCHES SHALL BE THINNED OUT WHERE NECESSARY. IN NO CASE SHALL TREES OR SHRUBS BE TRIMMED BY HEADING OR SHEARING, ANY PLANTS SEVERELY PRUNED IN THIS MANNER SHALL BE REMOVED AND REPLACED AT CONTRACTOR'S EXPENSE. Q. ON THE 80TH DAY OF THE ESTABLISHMENT PERIOD, ALL LAWN AREAS SHALL RECEIVE A TOP DRESSING OF 6 POUNDS OF 16-6-8 COMMERCIAL FERTILIZER PER 1,000 SQ, FT, R. ON THE 80TH DAY OF THE ESTABLISHMENT PERIOD, ALL LAWN AND GROUND COVER AREAS SHALL RECEIVE A TOP DRESSING OF 1 0 POUNDS OF 1 6-8-8 COMMERCIAL FERTILIZER PER 1,000 SQ. FT. S. AT COMPLETION OF ESTABLISHMENT PERIOD, ALIL AREAS INCLUDED IN THE CONTRACT SHALL BE SUBSTANTIALLY CLEAN AND FREE OF DEBRIS AND WEEDS. ALL PLANT MATERIALS SHALL BE LIVE, HEALTHY, AND FREE OF INFESTATIONS, T. ANY EROSION OR SLIPPAGE OF SOIL CAUSED BY WATERING SHALIL BE REPAIRED BY THE CONTRACTOR AT HIS EXPENSE. U. ALL WALKS, CURBS, AND GUTTERS SHALL BE KEPT CLEAR OF DEBRIS, MUD, DUST, AND STANDING WATER BY SWEEPING, MOPPING, OR HOSING DOWN AS REQUIRED TO MAINTAIN CLEANLINESS THROUGHOUT. daedalus design group landscape architecture: construction 2725 jcffcrson strccL suite 15h [·arlshml, callfornia ~)2008 rhonc 760/ 720-9337 APPROVED FOR PLANTING "AS BUil T" AND IRRIGATION ONLY, PLOT D,L\"rE: 3/30/05 INCLUDING PRECISE TITLE DATE ENGINEER'S SIGNATURE REQUIRED ON PAGE 1 ONLY LOCATION OF PLANTING REVIEWED BY: REVIEWED AREAS. ENGINEERING PLANCHECKER DATE INSPECTOR DATE I SH;ET I CITY OF CARLSBAD PLANNING DEPARTMENT ~ 0 LASUVERA ' FISHERMAN DRIVE CARLSBAD, CA 92008 PLANT SPECIFICATIONS (CONT.) APPROVEcl ~ WI~ V -- ASSISTANT PLANNING DIRECTOR DATE . DATE INITIAL OWN BY: PROJECT NO. DRAWING NO. I REVISION DESCRIPTION DATE INITIAL DAH INITIAL CHKD BY: ENGINEER OF WORK CDP 04-16 427ZL . OTHER APPROVAL CITY APPROVAL RVWD BY: : - -o 0 -t) \0 :)· u: I ... ,, ·::,.._.:··•''"" __J L.. ........ -····7 (._ . .;. -1 ' ~-r;::~~~::. ) ., YMB L -x:---x- DE RIPTI N 5' VINYL FENCING '\".": ''\: 0·~ ('J 5' ORNAMENTAL IRON FENCING I \ ' \ \ ' ' A ' /' ·-:-. / ·-:· '· ·,:· .. r ,/' •·>• I ' ' ' I , ,.. l? ' ' ' ' ' . 5' CMU FENCING WITH STUCCO FINISH, TEXTURE TO MATCH BUILDINGS::.· EXISTING CHAIN LINK FENCE 20 40 I I I I ii j j .ff . [~ I I C) 8'·0" VINYL FENCING SCALE: 1/2" = 1'-0" ____ 7/8" PVC U-CHANNELRAILS , TOP AND BOTTOM ___ 5" SQ. VINYL POST ---7/8"x6" T&G VINYL FENCE BOARDS ---CONCRETE FOOTING TO ACHIEVE 2000 PSI @28 DAYS .~ COARSE GRAVEL FILL ---COMPACTED SUBGRADE FINISHED GRADE NOTES: 1. FENCE COLOR TO BE WHITE. 8'0.C. .;.:;::;.=;.=;.=;.=;;=;;=;;=;;=;;;:::;;:::;;=;;=;;=;;;=;;=;;=;;=;;=;;=;;=~~---------1" SQ. TOP & BOTTOM RAIL _____ 1 1/2" SQ. POSTS 4 1/2" O.C. TYPc-..,------- l 1 _____ 5/8" PICKETS ~ ---COMPACTED SUBGRADE •= / ,,.,,,,..--FIN ISHED GRADE SCALE: 1/2" = 1'-0" CONCRETE FOOTING TO ACHIEVE 2000 PSI @28 DAYS NOT~E=:~------ 1. ALL METAL FENCING TO RECEIVE 1 COAT METAL PRIMER & 2 COATS OF SEMI. GLOSS METAL GRADE ENAMEL PAINT, COLOR TO BE BLACK. ------------8 x 4 x 16 SLUMPED BLOCK POUR CAP, 1'-0" MANUFACTURER TO BE ORCO BLOCK CO. ~~----2• MIN., 6" MAX. _____ 8 x 6 x 18 SLUMPED BLOCK, COLOR TO BE MISSION. MANUFACTURER TO BE ORCO BLOCK CO. MORTAR JOINT COLOR TO MATCH BLOCK. ____ KEY BLOCK INT O WET FOOTING ---FINISH GRADE CONCRETE FTG. TO ACHIEVE 2000 P.S.I.@ 28 DAYS 1-_, 111,-111 "'I II l 1 -iw------#4 HORIZ. REBAR CONTINUOUS Iii"'' "'li't'1='"_' ------SUBGRADE TO BE COMPACTED TO A MIN. OF 90% 111- ALTERNATE BEND IN FOOTING SLUMP BLOCK WALL (FREESTANDING) SCALE: 3/4" ~ 1'-0" "AS BUil T" TITLE ENGINEER'S SIGNATURE REQUIRED ON PAGE 1 ONLY REVIEWED APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. REVIEWED BY: ENGINEERING PLANCHECKER DATE INSPECTOR LA SUVERA FISHERMAN DRIVE CARLSBAD, CA. 92008 FENC AND WALL PLAN APPROVED 80 •---t-=;;c--t-=::-,--t---------------------t----t----t----t-----11 OWN BY: I = -= -= •= REVISION DESCRIPTION rHKn RY· I ENGINl:::lcR ni: wnR~ PROJECT NO. \ DATE DATE 11 DRAWING NO, ~ ....