Loading...
HomeMy WebLinkAbout2095 POINSETTIA LN; ; CBC2020-0400; PermitPrint Date: 05/18/2021 Permit No: CBC2020-0400 Building Permit Finaled Commercial Permit Job Address: Permit Type: Parcel #: Valuation: Occupancy Group: 2095 POINSETTIA LN, CARLSBAD, CA BLDG-Commercial $0.00 Work Class: Lot #: Project #: P/M/E DEV14060 Status: Applied: Issued: 10/02/2020 10/02/2020 Finaled Close Out: #of Dwelling Units: Track #: Plan #: Closed - Finaled PBurn Plan Check #: Inspector:Orig. Plan Check #:Bathrooms: Final Inspection:05/18/2021 Bedrooms:Construction Type: Occupant Load: Code Edition: Sprinkled: POINSETTIA 61: INSTALL 100A METER PEDESTAL (E-REVIEW)Description: Project Title:POINSETTIA 61 Property Owner: LENNAR HOMES OF CALIFORNIA INC 15131 ALTON PKWY, # UNIT 365 IRVINE, CA 92618-2385(949) 204-4628 Contractor: LENNAR HOMES OF CALIFORNIA INC 15131 ALTON PKWY, # UNIT 365 IRVINE, CA 92618-2385(949) 204-4628 AMOUNTFEE PLUMBING, ELECTRICAL, AND MECHANICAL PERMIT $175.00 Total Fees:$175.00 Total Payments To Date:$175.00 Balance Due:$0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. 1635 Faraday Avenue, Carlsbad CA 92008-7314 ï 760-602-2700 ï 760-602-8560 f ï www.carlsbadca.gov Building Division Page 1 of 1 {"Cityof Carlsbad 2095 Poinsettia LaneXMeter pedestal.100 amp meter pedestal.CBC2020-040010/2/2020( City of Carlsbad COMMERCIAL BUILDING PERMIT APPLICATION B-2 Plan Check ---------Est. Value PC Deposit ---------Date ---------Job Address ___________________ Suite: ____ APN: __________ _ Tenant Name: _s_D_G_&_E ____________ CT/Project #:. ___ C_T_l_4_-l_O ____ Lot#: ___ _ Occupancy: _________ Construction Type: ____ Fire Sprinklers: yes/ no Air Conditioning: yes/ no BRIEF DESCRIPTION OF WORK: ___________________________ _ D Addition/New: ___________ New SF and Use, ___________ New SF and Use, ____ Deck SF, Patio Cover SF (not including flatwork) D Tenant Improvement: _____ SF, _____ SF, Existing Use ______ Proposed Use ______ _ Existing Use Proposed Use ______ _ □ Pool/Spa: _____ SF Additional Gas or Electrical Features? ____________ _ D Solar: ___ KW, __ Modules, ___ Mounted, Tilt: Yes/ No, RMA: Yes/ No, Panel Upgrade: Yes/ No D Plumbing/Mechanical/Electrical Only: __________________________ _ D Other: ___________________________________ _ APPLICANT (PRIMARY) PROPERTY OWNER Name: _ .... I..,.,e .... n....,n..,a.._r_.H...,o...,m"-'-"'e..,_s ___________ Name: --=L::..;e;;.;cn;;.;;n;;.:a;;;:.r-=H=om=e:..::s ____________ _ Address: 15131 Alton Parkway, Suite 365 Address: _1_5_13_l_A_lt_o_n_P_a_rl_<w~ayc....:.,_S_u_it_e_3_6_5 _____ _ City: Irvine State: CA Zip: 92618 City: Irvine State: CA Zip: _9_26_1_8 __ Phone: (949) 204-4628 Phone: _ _,,(9--.-4_9_) =20.-,4.--4_6~2_8 _________ _ Email: Alan.Chik@Lennar.com Email: __ A_l_an_._c_h_il_<@_L_e_n_n_ar_._co_m _________ _ DESIGN PROFESSIONAL CONTRACTOR BUSINESS Name: Duane Stroobosscher Name: __ l...,.,-eo ... o ... a.,..r._H~ou..ro ..... e..,s..__ ___________ _ Address: 4429 Morena Blvd. Address: --=-1-=-5=13"-'l'""A'-=lt=on:.:....::.P...;:;a=rl=<W""-a=.y...,,""'S'""u=it=e..;;,3=6-=-5 _____ _ City: San Diego State: CA Zip: 92117 City: Irvine State: CA Zip: _92_6_1;;_;;8 ___ _ Phone: (858) 866-8544 Phone: _..,_(9_4_9-'--) 2_0_4_-4_6_2_8 __________ _ Email: des@utilityspecialists.com Email: Alan.Chik@Lennar.com Architect State License: ___________ _ State License: 728102 Bus. License: BLOS1239643 (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law {Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). 1635 Faraday Ave Carlsbad, CA 92008 B-2 Ph: 760-602-2719 Fax: 760-602-8558 Page 1 of 2 Email: Building@carlsbadca.gov Rev. 06/18 9/30/20 9/30/20 ( OPTION A): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury Q.D£ of the following declarations: DI have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. D I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Company Name: _____________________ _ Policy No. _______________ Expiration Date: __________ _ D Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to be come subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. CONTRACTOR SIGNATURE: □AGENT DATE: ----------------------------------- ( OPTION B ): OWNER-BUILDER DECLARATION : I hereby affirm that I am exempt from Contractor's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). 0(1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). D I am exempt under Section ________ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. D Yes D No 2. I (have/ have not) signed an application for building permit for the proposed work. 3. I have contracted with the following perso (firm) to provide the proposed construction (include name address/ phone/ contractors' license number): 4. I plan to provide portions of the work, b1.1 have hir e following person to coordinate, supervise and provide the major work (include name/ address/ phone/ contractors' license number): 5. I will provide some of the work, but I the following persons to provide the work indicated (include name/ address/ phooe / type of work): OWNER SIGNATURE: DATE:--=--~-- CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: ____________________ _ Lender's Address: ____________________ _ ONLY COMPLETE THE FOLLOW ING SECTION FOR NON-RESIDENTIAL BULLDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D Yes D No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D Yes D No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D Yes D No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIA8ILl1I , JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permi s required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. APPLICANT SIGNATURE: 1635 Faraday Ave Carlsbad, B-1 v· Ions of this Code shall expire by limitation and become null and void if the building or work authorized permit or if the building or work authorized by such permit is suspended or abandoned at any time ~ u?form Building Code). Ph: 760-602-2719 Fax: 760-602-8558 Page 2 of 2 Email: Building@carlsbadca.gov Rev. 06/18 ( soq(connecled A (6:'! Sempra Energy utility" ELECTRIC UNDERGROUND METER & SERVICE LOCATION Customer Copy Notification #: 300000260414 Job#: 1TB: 1127-D5 Wanted Date: ON INSPECTION Date Prepared: 04/11/2019 Customer Type: Commercial Service Type: UG SERVICE NEW Project Title: 2095 POINSETTIA LANE -NEW SVC Project Address: 2095 POINSETTIA LN I Project City: CARLSBAD Additional Address Info: Customer POC: DUANE STROOBOSSCHER Customer Phone #: 858-866-8544 SDGE Contact: Service Coordinator Contact Info: DEBRA STONE,7607397416 I I Traffic Control Permit Required [ZJSDG&E Application Required-Call: 1-800-411-7343 Excavation/Encroachment Permits Required By: Customer Municipal Inspection required By: CITY OF CARLSBAD I Temp Service Charge due on First Bill$ 0.00 SERVICE ATTACHMENT POINT AND/OR METER LOCATION: Face pedestal toward street & maintain 3' radial clearance around surface face of pedestal. Customers is to provide all excavation, trench, 3" conduit, backfill, compaction, 3/4" pulling and measuring tape in conduit and surface repair from 3309 handhole to new meter pedestal. STOP TRENCH 1" FROM HH OR AS INSTRUCTED BY TRENCH INSPECTOR. Address must be permanently marked on meter pedestal. PRE-MEET REQUIRED WITH SDG&E INSPECTOR PRIOR TO TRENCHING Station ID#: 1116-639 I Structure#: 3309 HANDHOLE I Joint Trench With: Electric Handhole Installed By: I Handhole Lid Shall Read: Standards Page: 3309.1 Ladder Arms: I Stop Trench: NIA from Pole Riser Quad: Bend Installed By: SDG&E I Bend Type: HANDHOLE Bend Info: 3" 90 DEG 36"R DB60 Conduit Installed By: CUSTOMER Conduit Size: 1-3" Service Panel Rating: 100 Number/Size of Main Switch: 1/100 I Voltage: 120/240 #of Wires:3 I Phase: 1 Utilities Maximum Contribution to Fault Current: 42000 Metering: Self Contained. Test Bypass Facilities Reqd Meter Clips: 4 Meter height --4'0" min. (3'0" min. for multiple Installation) --6'3" max. From finish grade to centerline of meter base. Meters are required to be readily accessible 24 hours per day. Meters must be located in a safe area tree of any potentially hazardous or dangerous condition. Provide 3-11. x 3-ft. clear and level working space in front of meter. Where meter room is proposed, contact the planner at the nearest SDG&E office. Meter bases and mete~ service disconnects must be located at or immediately adjacent to each other and be identified with address and unit number. PROCEDURE FOR INSTALLATION 1. PHONE DIG ALERT "811" AT LEAST TWO DAYS PRIOR TO TRENCHING FOR LOCATION OF UNDERGROUND UTILITIES. 2. Phone Service Coordinator at 7607397416 for the following: -3 Working days prior to trenching to arrange pre-meet with inspector and initiate trenching process. -After excavation of trench, installation of conduit and service entrance equipment at meter location, CALL FOR INSPECTION. Do not cover conduit without inspector's written approval to backfill. -When trench is backfilled and compacted, CALL FOR INSPECTION. -If service entrance equipment is installed after backfill, CALL FOR INSPECTION OF THE EQUIPMENT. 3. Meter cannot be set until inspector has approved installation, including service equipment, and receipt of city/county/state inspection Additional Information: Dight of Way Required Assessor's Parcel Number: Please call your Service Coordinator at 7607397416 with questions about application, inspection, construction installation and to schedule a crew. If SDG&E encounters hazardous or toxic material while performing construction of your project, SDG&E will halt work immediately and it will be your responsibility to remove and or clean up all hazardous or toxic material prior to SDG&E continuing construction. SDG&E shall have no liability or obligation whatsoever to cleanup, remove or remediate any hazardous or toxic materials discovered during the course of construction unless it is through negligence of SDG&E. Customer-owned facilities to receive gas service are subject to all applicable local and state of California inspection authority requirements. Building address and/or houseline must be permanently identified prior to meter set. Information on this sheet is void after six (6) months. Keep this notice with building permit. Planned By: Erica Jordan IPhone#:8586365765 NEW 100 AMP 1¢ 3W 120/240 METER PED. JOB NOTIFICATION: 300000260414 PLANNER NAME: Erica Jordan CONSTRUCTION CONTAC~ Linda Koenig CUSTOMER NAME: Duane Stroobosscher 75' 1-3" --- PROJECT NOTIFICATION: 300000200392 PLANNER PHONE: 858 636-5765 CONSTRUCTION NUMBER: (760) 432-5805 l-o Lu -1 0 cf 0 CUSTOMER PHONE NUMBER: (858) 866-8544 --- EX. STA 111 6-639 25 NTS D139122 NOTES --EX. 3316 HANDHOLE H115359 ~ CUSTOMER TO PROVIDE TRENCH & 3" CONDUIT Call 2 Working Days Before You Dig! 811 Building Permit Inspection History Finaled PERMIT INSPECTION HISTORY for (CBC2020-0400) BLDG-Commercial 10/02/2020Application Date:Permit Type:Owner:LENNAR HOMES OF CALIFORNIA INC P/M/E 10/02/2020Work Class:Issue Date:Subdivision: 11/15/2021Expiration Date:Status: IVR Number: 29112 Closed - Finaled 2095 POINSETTIA LN CARLSBAD, CA Address: Scheduled Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection InspectionActual Start Date 05/18/2021 05/18/2021 BLDG-33 Service Change/Upgrade 157607-2021 Passed Tony Alvarado Complete COMMENTS PassedChecklist Item BLDG-Building Deficiency May 18, 2021: 1. No building/electrical meter Deficiencies. 2. New electrical meter pedestal, grounding electrical conduit verified, scope of work-approved. Yes BLDG-Final Inspection 157608-2021 Passed Tony Alvarado Complete COMMENTS PassedChecklist Item BLDG-Electrical Final May 18, 2021: 1. No building/electrical meter Deficiencies. 2. New electrical meter pedestal, grounding electrical conduit verified, scope of work-approved. Yes Tuesday, May 18, 2021 Page 1 of 1 {cityof Carlsbad