HomeMy WebLinkAbout1540 JEANNE PL; ; CBR2021-0185; PermitPrint Date: 06/01/2021 Permit No: CBR2021-0185
Building Permit Finaled
Residential Permit
Job Address:
Permit Type:
Parcel #:
Valuation:
Occupancy Group:
1540 JEANNE PL, CARLSBAD, CA 92008-2604
BLDG-Residential
2071302000
$22,003.80
Work Class:
Lot #:
Project #:
Pool
Status:
Applied:
Issued:
01/21/2021
03/21/2021
Finaled Close Out:
#of Dwelling Units:
Track #:
Plan #:
Closed - Finaled
CRenf
Plan Check #:
Inspector:Orig. Plan Check #:Bathrooms:
Final Inspection:06/01/2021
Bedrooms:Construction Type:
Occupant Load:
Code Edition:
Sprinkled:
420 SF POOL/SPA (E-REVIEW)Description:
Project Title:
Applicant:
ACE HIGH CONSTRUCTION
TOBY DONNELLY
2422 UNICORNIO STCARLSBAD, CA 92009-5320
(310) 386-8912
Property Owner:
PETERSON GRANT & PETERSON SARAH
1540 JEANNE PL
CARLSBAD, CA 92008
Contractor:
TOMMY GERLACH
1471 BELLAIRE ST
OCEANSIDE, CA 92054-0000(310) 386-8912
AMOUNTFEE
BUILDING PERMIT FEE ($2000+)$230.27
BUILDING PLAN CHECK FEE (BLDG)$161.19 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL $41.00
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL $49.00
SB1473 GREEN BUILDING STATE STANDARDS FEE $1.00
STRONG MOTION-RESIDENTIAL $2.86 SWPPP INSPECTION FEE TIER 1 - Medium BLDG $246.00
SWPPP PLAN REVIEW FEE TIER 1 - MEDIUM $55.00
Total Fees:$786.32 Total Payments To Date:$786.32 Balance Due:$0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
1635 Faraday Avenue, Carlsbad CA 92008-7314 ï 760-602-2700 ï 760-602-8560 f ï www.carlsbadca.gov
Building Division Page 1 of 1
{"Cityof
Carlsbad
1855-11-2017
CBR2021-0185
23,575
1/21/21
(\__ City of
Carlsbad
RESIDENTIAL
BUILDING PERMIT
APPLICATION
8-1
Pl an Ch eck _______ _
Es t . Val ue
PC Deposi t
D ate _______ _
.,j::.-----Job Address \'54-D ~ {~ l--Z& ,R Suite: ____ APN: __________ _
CT/Project #: ___________________ Lot #: ____ Year Built: ________ _
Fire Sprinklers: OvES Electrical Panel Upgrade~sO NO
0 Addition/New: _____ Living SF, ____ Deck SF, ____ Patio SF, ____ Garage SF __ _
Is this to create an Accessory Dwelling Unit? OY~ New Fireplace? Ov~ if yes how many? __
0Remodel: _____ SF of affected area Is the area a conversion or change of use? Ov ON
~ool/Spa: <'\9..) SF Additional Gas or Electrical Features? ¼s ~ ~
osolar: ___ KW, ___ Modules, Mounted :ORoofOGround, Tilt:OvO N, RMA:OYON,
Battery:OY ON, Panel Upgrade: Ov ON
D Reroof: -----------------------------------□ Plumbing/Mechanical/Electrical
0 Only: Other:
This permit is to be issued in the name of the Property Owner as Owner-Builder, licensed contractor or Authorized Agent of the
owner or contractor. The person listed as the Applicant below will be the main point of contact throughout the permit process.
1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Bui\din8(ulcarl sbadc~.eov
REV. 08/20
IDENTIFY WHO WILL PERFORM THE WORK BY COMPLETING (OPTION A) OR (OPTIO J B} BE LOW :
(OPTION A): LICENSED CONTRACTOR DECLARIHION:
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000} of Division 3
of the Business and Professions Code, and my license is in full force and effect. I also affirm under penalty of perjury one of the
following declarations:
0 I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the
work which this permit is issued. Policy No. ________________________________________ _
0 I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
My workers' compensation insurance carrier and policy number are: Insurance Company Name: _____________________ _
Policy No. _____________________________ Expiration Date: _______________ _
~cate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become
subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful and shall subject an employer to
criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code,
interest and attorney's fees.
CONSTRUCTION LENDtNG AGENCY, IF ANY:
(OPTION B): OWNER-BUILDER DECLARATION :
I hereby affirm that I am exempt from Contractor's License Law for the following reason:
0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec.
7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work
himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: Th e
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
0 I am exempt under Business and Professions Code Division 3, Chapter 9, Article 3 for this reason:
O"owner Builder acknowledgement and verification form" has been filled out, signed and attached to this application.
0 Owners "Authorized Agent Form" has been filled out, signed and attached to this application giving the agent authority to obtain the permit on the owner's behalf.
By my signature below I acknowledge that, exce pt for my personal residence in which I must have resided for at least one year prior to completion of the
improvements covered by this permit, I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by licensed
contractors. I understand that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application is
submitted or at the following Web site: http://www.leginfo.ca.gov/calaw.html.
OWNER PRINT: SIGN: ___________ DATE: ______ _
APPLICANT CERTIF ICATION: SIG NATURE REQU IRED AT THE TIME OF SU BM ITT AL
By my signature below, I certify that: I am the property owner or State of California Licensed Contractor or authorized to act on the property
owner or contractor's behalf. I certify that I have read the application and state that the above information is correct and that the information on
the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction.
J hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE,
INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE
AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0' deep and
demvUtioo v, wo<twchv, of"'"""'" ooe, 3 ,,ht. ~. ~ ~ ../!!
APPLICANT PRIN~~~ SIGN~ ~ DAT~ IS 2c)Z-/
1635 Farad ay Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Buildirw1:,1c;irl,b~cic;i .,,_ov
2 REV. 08/20
Building Permit Inspection History Finaled
PERMIT INSPECTION HISTORY for (CBR2021-0185)
BLDG-Residential 01/21/2021Application Date:Permit Type:Owner:COOWNER PETERSON GRANT &
PETERSON SARAH
Pool 03/21/2021Work Class:Issue Date:Subdivision:HOLIDAY MANOR
10/18/2021Expiration Date:Status:
IVR Number: 31111
Closed - Finaled 1540 JEANNE PL
CARLSBAD, CA 92008-2604
Address:
Scheduled
Date
Inspection Type Inspection No. Inspection
Status
Primary Inspector Reinspection InspectionActual
Start Date
03/23/2021 03/23/2021 BLDG-SW-Pre-Con 153254-2021 Passed Chris Renfro Complete
COMMENTS PassedChecklist Item
BLDG-Building Deficiency Yes
03/25/2021 03/25/2021 BLDG-51
Excav/Steel(Pools)
153451-2021 Passed Tony Alvarado Complete
COMMENTS PassedChecklist Item
BLDG-Building Deficiency March 25, 2021:
No building-swimming pool deficiencies.
1. In ground, Gunite, pool reinforcement
steel, per structural pool engineers plans
and detail sheet-100/Pool engineering
company specifications-approved.
2. Underground cool pipe plumbing under
water leak pressure test.approved.
3. Underground electrical conduit
protected-approved.
4. Underground, plumbing poly propylene
gas line with yellow tracer wire, and gas
gauge under air pressure test-approved.
5. (4) + location points at perimeter of pool,
for stubbed-out equipotential pool bond
wire-partial pass.
Yes
BLDG-52 Pool Plumbing 153452-2021 Passed Tony Alvarado Complete
COMMENTS PassedChecklist Item
BLDG-Building Deficiency March 25, 2021:
No building-swimming pool deficiencies.
1. In ground, Gunite, pool reinforcement
steel, per structural pool engineers plans
and detail sheet-100/Pool engineering
company specifications-approved.
2. Underground cool pipe plumbing under
water leak pressure test.approved.
3. Underground electrical conduit
protected-approved.
4. Underground, plumbing poly propylene
gas line with yellow tracer wire, and gas
gauge under air pressure test-approved.
5. (4) + location points at perimeter of pool,
for stubbed-out equipotential pool bond
wire-partial pass.
Yes
BLDG-53
Elec/Conduit/Wiring(Po
ols)
153454-2021 Passed Tony Alvarado Complete
Tuesday, June 1, 2021 Page 1 of 4
{cityof
Carlsbad
PERMIT INSPECTION HISTORY for (CBR2021-0185)
BLDG-Residential 01/21/2021Application Date:Permit Type:Owner:COOWNER PETERSON GRANT &
PETERSON SARAH
Pool 03/21/2021Work Class:Issue Date:Subdivision:HOLIDAY MANOR
10/18/2021Expiration Date:Status:
IVR Number: 31111
Closed - Finaled 1540 JEANNE PL
CARLSBAD, CA 92008-2604
Address:
Scheduled
Date
Inspection Type Inspection No.Inspection
Status
Primary Inspector Reinspection InspectionActual
Start Date
COMMENTS PassedChecklist Item
BLDG-Building Deficiency March 25, 2021:
No building-swimming pool deficiencies.
1. In ground, Gunite, pool reinforcement
steel, per structural pool engineers plans
and detail sheet-100/Pool engineering
company specifications-approved.
2. Underground cool pipe plumbing under
water leak pressure test.approved.
3. Underground electrical conduit
protected-approved.
4. Underground, plumbing poly propylene
gas line with yellow tracer wire, and gas
gauge under air pressure test-approved.
5. (4) + location points at perimeter of pool,
for stubbed-out equipotential pool bond
wire-partial pass.
Yes
BLDG-54 Equipotential
Bond(Pools)
153453-2021 Partial Pass Tony Alvarado Reinspection Incomplete
COMMENTS PassedChecklist Item
BLDG-Building Deficiency March 25, 2021:
No building-swimming pool deficiencies.
1. In ground, Gunite, pool reinforcement
steel, per structural pool engineers plans
and detail sheet-100/Pool engineering
company specifications-approved.
2. Underground cool pipe plumbing under
water leak pressure test.approved.
3. Underground electrical conduit
protected-approved.
4. Underground, plumbing poly propylene
gas line with yellow tracer wire, and gas
gauge under air pressure test-approved.
5. (4) + location points at perimeter of pool,
for stubbed-out equipotential pool bond
wire-partial pass.
Yes
BLDG-57 Gunite 153551-2021 Passed Tony Alvarado Complete
Tuesday, June 1, 2021 Page 2 of 4
PERMIT INSPECTION HISTORY for (CBR2021-0185)
BLDG-Residential 01/21/2021Application Date:Permit Type:Owner:COOWNER PETERSON GRANT &
PETERSON SARAH
Pool 03/21/2021Work Class:Issue Date:Subdivision:HOLIDAY MANOR
10/18/2021Expiration Date:Status:
IVR Number: 31111
Closed - Finaled 1540 JEANNE PL
CARLSBAD, CA 92008-2604
Address:
Scheduled
Date
Inspection Type Inspection No.Inspection
Status
Primary Inspector Reinspection InspectionActual
Start Date
COMMENTS PassedChecklist Item
BLDG-Building Deficiency March 25, 2021:
No building-swimming pool deficiencies.
1. In ground, Gunite, pool reinforcement
steel, per structural pool engineers plans
and detail sheet-100/Pool engineering
company specifications-approved.
2. Underground cool pipe plumbing under
water leak pressure test.approved.
3. Underground electrical conduit
protected-approved.
4. Underground, plumbing poly propylene
gas line with yellow tracer wire, and gas
gauge under air pressure test-approved.
5. (4) + location points at perimeter of pool,
for stubbed-out equipotential pool bond
wire-partial pass.
Yes
04/19/2021 04/19/2021 BLDG-54 Equipotential
Bond(Pools)
155450-2021 Passed Tony Alvarado Complete
COMMENTS PassedChecklist Item
BLDG-Building Deficiency April 19, 2021: (Virtual inspection).
(No swimming pool/building deficiencies).
1. Perimeter yard fencing, side yard gates,
and doors with alarms leading out to pool
area, scope of work-approved.
2. Equipotential pool bond wire verified at
(4)-connection areas at pool perimeter
location points around pool, equipotential
pool bond wire surrounding entire
perimeter of swimming pool-verified and
approved.
Yes
BLDG-Building Deficiency March 25, 2021:
No building-swimming pool deficiencies.
1. In ground, Gunite, pool reinforcement
steel, per structural pool engineers plans
and detail sheet-100/Pool engineering
company specifications-approved.
2. Underground cool pipe plumbing under
water leak pressure test.approved.
3. Underground electrical conduit
protected-approved.
4. Underground, plumbing poly propylene
gas line with yellow tracer wire, and gas
gauge under air pressure test-approved.
5. (4) + location points at perimeter of pool,
for stubbed-out equipotential pool bond
wire-partial pass.
Yes
BLDG-55
Fence/Preplaster
155209-2021 Passed Tony Alvarado Complete
Tuesday, June 1, 2021 Page 3 of 4
PERMIT INSPECTION HISTORY for (CBR2021-0185)
BLDG-Residential 01/21/2021Application Date:Permit Type:Owner:COOWNER PETERSON GRANT &
PETERSON SARAH
Pool 03/21/2021Work Class:Issue Date:Subdivision:HOLIDAY MANOR
10/18/2021Expiration Date:Status:
IVR Number: 31111
Closed - Finaled 1540 JEANNE PL
CARLSBAD, CA 92008-2604
Address:
Scheduled
Date
Inspection Type Inspection No.Inspection
Status
Primary Inspector Reinspection InspectionActual
Start Date
COMMENTS PassedChecklist Item
BLDG-Building Deficiency April 19, 2021: (Virtual inspection).
(No swimming pool/building deficiencies).
1. Perimeter yard fencing, side yard gates,
and doors with alarms leading out to pool
area, scope of work-approved.
2. Equipotential pool bond wire verified at
(4)-connection areas at pool perimeter
location points around pool, equipotential
pool bond wire surrounding entire
perimeter of swimming pool-verified and
approved.
Yes
06/01/2021 06/01/2021 BLDG-Final Inspection 158592-2021 Passed Paul Burnette Complete
COMMENTS PassedChecklist Item
BLDG-Building Deficiency Yes
BLDG-Plumbing Final Yes
BLDG-Mechanical Final Yes
BLDG-Structural Final Yes
BLDG-Electrical Final Yes
Tuesday, June 1, 2021 Page 4 of 4