Loading...
HomeMy WebLinkAbout2440 STROMBERG CIR; ; 82-133; Permitti) z 0 ~ ac <( ... u ... a ~ e[ a: ... z 0 u ac ... a ... 5 I ... z ~ z 0 .:: ~ z ... Q. ::E 0 u ti) a: ... "' ac 0 3 ir 0 I herel,7 ittlrm that I am I provisions of Chapter 9 (com Section 7000) of Division 3 of and Professions Code, and my full force and effect. lie No _____ Class _ ,m lhe Con-I hereby artirm that I am exem'1 ¥:~~-~~~f::: ~w ~t~'::1~~ reason (Sec . . Any city or onstruct county which requires a permit t alter. imp,ove, demolish, or r&pai1 prior to its issuance also requires t such pennit to tile a signed statemen Ucensed pursuant to the provisions tractor's license Law (Chacter 9 com Section 7(XX) of D1v1s,on 3 ot the Bus; fesstOns Code) or that 1s e,cempt thet basis f0t the alleged exemptK>n. A Section 7031 5 by an applicant tor a 1y structure, applicant for 1t that he IS DI lhe Con- tencing with tss and Pro-rom and the vtOlattOn of -nit subjects tne applicant to a civil penalty of no hundred dollars ($50()) . □ I, as owner ol the property, or .. 11h wages as their sole compensa wOf'k, and the strvcture is not intended sale (Sec 7044, Business and Pro The Contractor's Lteense Law does owner of property who builds or irr and who does such WOfit himself or employees. provided that such im :>re than five employees , will do the ,rotfe<ed for sions Code: apply to an ves thereon ugh his own 'effle;'lts are owever, the not mtende1 or ottered for sale I building or improvement 1s sold w11 completion. the owner-buildef' will have of proving that he did not build or one year of the burden rove for the purpose of sale). □ I, as owner ot the property, contractin9 with licensed contractOf the P,OJect (Sec. 704A, Busmes·s and Code: The Contractor's License Law to an owner of property who bu1h thereon, and who contracts for each contractorts~ hcense pursuant to t License Law) e•r.lus1vely o construct Prt>fess1ons es not apply >r improves ~ects with a ...ontr.ctor·s 0 I am exempt under Sec __ _ __ ,B.&PC. for this reason ______ _ 0 I hereby affirm that I ha·..-e a cert11 10 self-insure, or a cert1hca1e Compensation Insurance, or a cert1f (Sec 3800. Labor Code). POLICYNO~, COMPANY ate of con~n1 of Work.,,s· :I copy the"401 ~'1EJ8 . - -------. -----. --------~ )--CARLSBAD BUILDING DEPARTMENT 0 ----------. ----r --------·-. --- APPLICATION & PERMIT .... 7' 1200 Elm, Carlsbad, California 92008 (71<1) "38-5525 JOB ADDRESS A~:Trr;1;p Ir~ BUSINESS LICEI\ISE # VALUATION PERMIT NUMBER B4t\D g1.1Q'J•J u,o,,,, s-"L1,,,05 ti,3o(p ~-1?3 I OWNER'S NAME .. . 11~:;~ ~,~~~RACTOA vi ~ CONTIIACTORS PHONE t ZONE cL..ll'~ .... \ Kl\. n ~.....__\ ~• ~ \I ,'2.A-2A44 I OWNER'S'MAILING ADDRESS M,TZ:ADD~ lU.. ~,~ UCENSENO. PLAN 1.0, # BLOG USE CODE ' ~()/,,,JI I LOT I BLOCK I SUBDIVISION I PARCEL NO. r1 0£S1GN£R STATE LICENSE# STANDARD PLAN # BUILDING SO. FOOTAGE I 11,;1--~-::----~ -nn 1A~ ~:t?:r I DESCRIPTION OF WORK . I . OESIOIMR'S ADDRESS DESIGNER'S PHONE I &QOIJ\.( I '1..lb..,.__~·1 (wpm 6/07 IB26uJi9 i i'-~ I -)Jc,o\L ' ~l)t..}-, F/P F LR ELEV. NO OCCGP EDU ~ao 1_e45r -~ 01102 STORIES t vO NO '2/ 12-3 --' CENSUS TRACT I GP LANO USE I PARKING SPACE RES UNITS I GRADING J'.ERMIT ISSUED I REDEVELOPMENT OCC LOAD r ~~ FIRE SPR TO N izr AREA ,rt' ~ YON /0 vO NO Not Valid Un~s ~chine Certifi«I f SUMMARY/ACCOUNT NU~ _ ~ 1 QTY. PLUMBING PERMIT -ISSUE )1,5;) QTY. MECHANICAL PERMIT -ISSUE .5'. l)i I ~---t 4 EACH FIXTURE TRAP f AJ .171 INSTALL FURN. DUCTS UP TO 100,000 BTU BUILDING PERMIT 01-Mt>/4"o ~l',,Jn t EACH BUILDING SEWER OVER 100,000 BTU SIGN PERMIT ...-111-000-4221 l --I EACH WATER HEATER ANO /OR VENT I'/ -/1!£, BOILER/COMPRESSOR UP TO 3 HP PlAN CHECK ~ 01-000-4806 /,,..U-,f)J t f I EACH GAS SYSTEM 1 TO 4 OUTLETS 11 -.4". BOILER/COMPRESSOR 3-15 HP 'TOTAL PLUMBING_/ 01-000-4222 ~n_.4n EACH GAS SYSTEM 5 OR MORE I METAL FIREPLACE ,;;t.dl} ELECTR~ 01 -000·4223 --, ~ (Ft) f EACH INSTA~ .. ALTER, REPAIR WATER PIPE VENT FAN SINGLE DUCT ,, ~NICAL /., vl) I 01 ·000-4224 V MOBILEHOME I EACH VACUUM BREAKER MECH EXHAUST -HOOD/DUCTS 01-000-4225 f WATER SOFTNER RELOCATION Of EA FURNACE/HEATER J_,"IJ / MOBILEHOME PARK INSP I EACH ROOF DRAIN (INSIDE) II /IV-SOLAR 01 ·000-4226 I TOT.t;L MECHANICAL _.11'}P(t:,d) STRONG MOTION 65-640-0519 ~.t.. I I I TOTAL PLUMBING I 1/J ~· FIRE SPRINKLERS 01 ·000-4227 t -P' PUBLIC FACILITIES FEE f QTY. ELECTRICAL PERMIT · ISSUE QTY. SOLAR · IS) UE 25-000-4933 _,.,, 00 BRIDGE FEE □ Copy IS hied with the city ~rt,hed CoPY IS hereby furnished ~~ NEW CONST EA AMP/SWT/BKR 1 PH 3 PH COLLECTORS ✓ STORAGE TANKS / //IV -.J V SCHOOL FEE • DISTRICT JY /jff / Carlsbad 65-623-0519 FROM ,URANCE CERTIFICATl OF EXEMPTIO WORKERS' COMPENSATION II (This section need not be completed 1f the permit 1s tor one hundred oonars {$100 D I certify that in the performance which lh1s permI1 IS !$Sued, I shall person ,n any manner so as to bee lhe WOOl,ers· Compensa11on Laws o NOTICE TO APPLICANT II. alter m ficate of Exemption, you should bee the Wof11.ers· Compensatton prov1s1on Code, you must forthwith compl provisions or lh1s perm11 shall be dee 0 I hereby affirm that !here 1s lending aoency tor the performance wh,ch this permI1 Is ,ssued (Sec J09 l ender's Name ______ _ LenOef's Address _____ _ IOt' ~SS) t the wont for >1 employ any ne sub,ect to ::a11torma In~ this Cert• me sub1ect t? s of the Labor t with such med revokeo construction ff the work tor r. C1v1I Code) I I I l I I l EXIST BLOG EA AMP/SWT/BKR ROCK STORAGE / Au I Encinitas 65-624-0519 I PH 3 PH PUMP / // V San Oieguito 65-625-0519 I REMODEL/ALTER PER CIRCUIT c::; C;£,, PlAN CHECyfE San Marcos 65-626-0519 TEMP POLE 200 AMPS / _,,,,.., /'""'\ -r J /" -... ) OVER 200 AMPS / .:Jl.t-( ~ -i 'T".~ \I'~ { /7/.S - TEMP OCCUPANCY (30 DAYSI ./ '-. V TOTAL ELECTRICAL I -,_a TOTAL SOLAR TOTAL FEES PAYABLE I €31 ,{pb I HAVE CAREFULLY EXAMINED THE OOMPLETEO k~NI) :=:!E · .,. ~.,,.,,._.,,. ........... Olflcllllunclar-=oftllia * AN 0INA PERMIT IS IIEQUIAED FOR EXCAVATIOMS OVER CERTIFY UNDER PENALTY OF PERJURY THAT ALL i110N . THE ...... . llld~nullMd'IGlcl N'-Dr-'! .5• 0-DEEP ANO DEM0UllON OR CONSTRUCTION OF DECLARATIONSARETRUEANOCORRECTANDtfURl'lllfltl!RnfYANDAORl!l!IPA . IS ~Mll--ll-____,wllllln-,-,.hM.. °'-" STAUCnNSOVEA3SlORIES W HEIGHT ISSUED: TO COMPLY WITH ALL CITY, COUNTY ANO sj,.,. l.AV$GOVEANINQ ~ OOH, Pl(!lllt. « ~ ~ ...._ • 1111111. -:-a-11J -e ...... ~ ~ •-...._ or STRUCTION. WHETHER SPECIFIED HEREIN OR NOT. I A"8() AGREE TO SAVE INPBIIIIF'l MfD N'l'UC'NIIP8 IIGNAW • 0 0 APPROVED BY DATE KEEP HARMLESS THE CITY OF CARLSBAD AGAINST AU. UAaUTa, JUll8MEN18, 0081S ANO OWNER CONTRACTOR ~ EXPENSES WHICH MAY IN ANY WAY ACCRUE ACW1!!8f .,_., Qt'Y IN C01Ailjlli1ll!M'(E qtF nil: BYPHONI 0 I h·,-~ GRANTING OF THIS PERMIT. ~ u: >-~ 0 a. E Q) I- I " 0 (!l c <1l 0 ~· a •C I .,c: C a: 0 "' "' Q) "' "' < I 3: .2 ai >- "' "' Q) 0 0 0: <1l iii 0 ~ Q) 0 C <1l C u: :s C Q) ~ (!l 0 0 Q) a. "' C 2! L: ~ INSPECTION TYPE DATE INSPECTOR BUILDING i . FO~NDATION I ' REINFORCED STEEL ' MASONRY i l GUNITE OR GROUT r FLOOR & CEILING SUB FRAME I ' SHEATHING I FRAME I I EXTERIOR LATH lNSULATION I I INTERIOR LATH & DRYWALL I -,, ~g ,,I),-?_ t .JJ. PLUMBING I ~, ...._~_j -- SEWER AND BL/CO , l PLUMBING UNDERGROUND 11 T PLUMBING TOP OUT I TUB AND ~HOWER PAN j GAS TEST i ELECTRICAL T TEMPORARY POWER I I ELECTRIC UNDERGROUND ~I I ROUGH ELECTRIC I ELECTRIC SERVICE t BONDING A I ' G. F. I. -SMOKE DETECTOR t MECHANICAL r l DUCT & PLEM., REF. PIPING , I HEAT -AIR COND. -SOLAR SYST6JMS • I VENTILATING SYSTEMS : • I . . ~ CALL FOR FINAL INSPECTION ~HEN All APPROPRIATE ITEMS ABOVE HAVEi BEEN APPROVED. ' JOB SITE FINAL PLUMBING ELECTRICAL MECHANICAL GAS BUILDING SPECIAL CONDITIONS CERT OF OCCUP.:..:A.:..:N-=C..:...Y...:.IS::.:S=-:U::.:E=-=D=--------,.---1.-__ __. _ ___,._ FIELD INSPECTION RECORD REOUl~ED SPECIAL INSPECTIONS REQ IF INSPECTOR'S INSPECTION CHECKED APPROVAL DATE SOILS COMPLIANCE PRIOR TO FOUNDATION INSP STRUCTURAL CONCRETE OVER 2000 PSI PRESTRESSED > I CONCRETE ' POST TENSIONED CONCRETE FIELD WELDING <'., HIGH STRENGTH . BOLTS SPECIAL MASONRY PILES CAISSONS I \ \, ' ' •· I . ,. . -. . -r • -; ' ~-~ ' ~ ' ,. . J . ' r --. ...... 'i?:),.\£> '3 r INSPECTOR'S NOTES C I ••--T ~•4 •---i: J.-~ -r·., t-\.. Jc:,:' ..... •.":., i • ; .__ -~ \ ,. ' ' .. I --'i. I '-P' .. \ ,, .. - ·~ ...... , ,. "• ,. ~ ' -.. ~ ) . 't" . -\;. -\ ' -. . . ~ f ._ '~ I. . ,. -"' ~ . -:; ' . -., -. •, ... '· ' ' y ' ... I l \ f ..;:, . •. ,, -· ' . .. .. ' ·--r ' . ' . . ( '' ~' ~ ...... ~ rl---I "', .... , -,_ ..... ,' I ' .. ,. \ .... ,._ __ I \ I < r .:. . " " -.. \" ........... .. ~ ' ' ESGIL CORPORATION 9320 CHEl'IAPEAKE DR., !ilt_TJTE 122 HAN DIEGO, CA 9212:J 9 (). _;_ I 3 3 (Tl•t.) 1'580-140~ t< 11/ /(-:::el-. ~ I lfc51Z J Qtitp of Qtarl.ubab Pr~: ~ 0 Q. A-H.- tf\ I~ • CvY1 <;.T. S(?3C~ I d -r. L-1u/J2._;, JUR ISDICTION ,"l'J~{3tif'-,V DATE~ PROJECT ADDRESS: "l.44/J Sd.aJl/l[B~ C'Jl2Cl.t::- TO : _______________________ _ PLAN CORRECTION SHEET SINGLE FAMILY AND DUPLEX DWELLINGS Plan Check No. 82.-/33 _::o::_ :)ate plans received by plan checker_,_.....;: __ -J.....;.,.==.- natc i nitial plan check completed~by ' CiiizoRDY~~b7Z-1/-/ ?lan check~l imited t o technical requirements contained in the Uniform Building Code , Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state l aws r egul ating energy conservation, noise attenuation and access for the handicapped. The plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department o r other departme nts. The items circled below need clarification, modification or change. All circled items have tc be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303 (c), 1979 Uniform Building Code, the approval of the plans does not per mit the violation of any state, county or city law. Please make all corrections on the original tracings and submit two new sets of prints, and any or igina l pl a n sets that may have been returne d to l:'u by the j urisdiction, tc,: R.PI LVPK~ :::pe:er: To facilitate r echecking, please identify, next to each circled item, the sheet of the plans upon which each correction on thi s sheet has been made and return this check sheet with the r evised plans. Indicate on plans the name of the l egal own<'r and name of person responsibl e for the preparation of the pl ans. Sec. 302(b) D APPLICANT COPY <:::'.'. -□ CITY COPY > D PLAN CHECKER COPY .✓.-----submit ~ul ly dimensioned plot pl an drawn / to scale showing loc3tion size, and use of all existing and proposed structures on the lot. Ide ntify property lines and show l ot dimensions and all easeme nts. Show location of all cut or fill slopes and approximate finish floor elevati ons for all structur es and show e l evations at all corners. Sec. 302Cbl 7. /,ndicate distance from center-li ne of stree t /. ~r a lley to property line and distance f rom curh to property line. Sec. 302(bl7 Plans, specifications and cal culations shall be s igned by a Cal ifornia State l icensed e ngineer or architect. (California Business and Professions Code) n . FIR~ PROTECTION '~alls c loser than 3 feet to property lines r· ;hal l be one-hour fire-rated construction, have no openings, and shall have 30 i nch parapets when the building floor a r ea exceeds 1,000 square f eet on any f l oor. (Table 5-A Sec. l 709 (al /Projections, incl uding eaves, may not extend more than 12 inches into the 3 foot setback from the property line. Sec. 1710 and Sec. 504(b) ~Projections, inc l uding eaves, s hall be one-✓· hour fire -resisti ve construction, heavy timber or of non-combustible material if t hey pr oject into the 3' setback ~,ea from the property line. Sec. 1710 Show location of p..:rn,,,ne ntly wir,sd smoke dr t ~ctor. Sec. 1210 t"c_ ROOM SI ZES 1 l,IGHT1 VENTILATIONS AND GLAZING ,/ One room must contain a mini m•Jm of 150 square / ·· feet of superficia l floor ari:•,1. Sec. I 207(b) /· ll<1 bi table r ooms , oth••r t.han k1 tcr•cns, s hall contain at least 70 sq•rnrt' f eet o f Cloer <1rea . Sec. 1207(h) ~indow area must Le at least 1/10 of the floo r are a and a minimum of 10 square feet per Sec. 1207(a). Appears to be deficient in Openable window area muse be 1/20 of the floor a r ea and a minimu~ of 5 square f eet. In bathrooms , laundr y rooms and similar rooms. Mi nimum is 1 .5 sq.ft. (Sec.1205(a) One -half of all required window area must be openable in Provide mechanLcal ventilation capable of provid ing five air changes per hour in bathrooms, wate r closet compartments, laundry r ooms and similar r ooms if required windows arc not provid~d. Sec. 12051a) ,✓ No habitable room, 0 ther than a kitchen, / · s hall b~ less than 7 '(1'' in any riimension. Ser.. 1207 (c) Show that ceiling he ight for habitable r ooms i s a minimum of 7'6". Sec. 1207(a) ( ~t.A)S~u 1 ·, • ·, .n . .c·"'•·, · · p,, ,t,,1L s c, t-1 ~ . ~ \I,.(? \ \ll"'lc.. _,,,,,., ' ... _ \:•\,c::.. +~« .• 'A-;1),'\hl"'1- y· Show ceiling height for laundry rooms, hallways, corridors, and bathrooms is a minimum of 7'0". Sec. 1207(a) ~Provide JO" clear width for water closet /' --compartments and 24" clearance in front of water closet. Sec, 17ll(b) ../,o cooking room shall be used for sleeping /· ~urposes, unless complying as an efficiency living unit. Sec, 1208 / Specify safety glazing for glazing in hazardous /~· locations such as glass doors, glazing adjacent to such doors and glazing adjacent / to walking surfaces. Sec. 5406 Glazing in shower and tub enclosures (including windows) shall be tempered, laminated or approved plastic. Sec. 1711 (f)(gl £steeping rooms shall have a window or / exterior door for emergency exit. Sill height shall not exceed 44" above the floor. The window must have an openable area of at least 5.7 square feet with the minimum openable width 20• and the minimum openable height 24•. Sec. 1204 Eaves and cornices may not project into a required yard more than 2 inches for each foot of yard width if required windows open into the yard. Sec. 1206(d) 40/'A mezzanine is an intermediate floor and / may not have a floor area exceeding 33 1/3 percent of the total floor area in the room below, and the mezzanine floor must have a clear height of 7 feet, above and below,and must have 651 of the long side open to the room below. A'.,.-;he loft you show does not comply as a y· ~ezzanine floor and is, by Building Code D. 4&. definition, a story ______________ _ EXITS, STAIRWAYS, AND RAILINGS Floors above the second story shall have not less than 2 exits. Sec. 3302(a) Required exit doorways shall be not less than 36• in width and not less than 6 1 -a· in height, and shall be capable of opening at least 90 degrees. Sec. 3J03(e) Provide 36" high protective railing for porches, balconies, and open sides of landings. Maximum opening between railings shall be less than 9•. Sec. 1716 Show how guardrail connection details are adequate to support 20 pounds per lineal foot at a right angle to the top rail. Table 23-B ✓-· Provide stairway and landing details. / Sec. 3305fbl & (cl a. Maximum rise a• and minimum run is 9". b. c. Min1mum head room is 6'-6". Minimum width is 30". . Handrails shall satisfy the following: a. Provide handrail for stairways over 30• high when serving a single dwelling. Title 24, Sec, T25-22(bl Handrail shall be 30• to 34• above the nosing of treads. Sec. 330S(j) Handrail projecting from a wall shall have a space not less than 1 1/2" between the wall and the handrail. The hand grip portion of handrail shall be not less than 1 1/4" nor more than 2" in cross-sectional .dimension. Sec. 3305(j) (see attached! ✓ Every stairway landing shall have a dimension, / •. measured in the direction of travel, at least equal to the stairway width. sec. 33051gl 5~ door may open over a stairway landing / provided the door, in any position, does not reduce the clear area of the landing, in the direction of stairway travel, to less than one-half the required width of the stairway. Sec. 3305(g) / ,A door may open inward at the top step of a stairway provided the top step is not more than 7 1/2" lower than the floor level. _ /e. 3303(il2 /· ~rovide details of winding stairway. a. Minimum tread is 6 inches at any point and minimum 9 inches at a point 12 inches from the side of the stairway. b. Maximum rise is 9 inches. c. Minimum width is JO inches. Sec. JJ05(d) // (see attached) _J'!· Provide spiral stairway details: · a. Minimum run is 7 1/2 inches at a point from where the tread is the narrowest. b. Maximum rise is 9 1/2 inches. c. Minimum headroom is 6 feet 6 inches. Sec. 3305(f) (see attached) Sprial stairways may not be used for required exits when the area served is greater than 400 sq. ft. Sec. 3305 ( f) / Spiral stairways must have a clear walking / pace of 26 inches between the column and andrail, Sec. 3305(f) 5)L rovide I.C.8.0. Reasearch Report and Number or metal stairway, or submit plans and calculations and approved fabricator registered with the Building Department or note that the stairway fabrication shall be done under special inspection per the approved fabrication plans. Sec, 306(a)4B and sec. 306(fl In buildings over 2 stories in height, provide 3/4 hour fire-rated assemblies for all openings in the exterior wall below or within 10 feet horizontally of an exterior stair- way. An exit balcony with 2 separated stairways is ~:-c~mpt.. Sec. 3305 Exterior stairways 5hall not project into the 3 foot setback from the property lines. Sec. 3305(n) '. ~\-fT.~. Sbou~ 2.1e.1t: •~,•~I I \' j>. The walls and soffits of the enclosed us~able space under interior stairs shall be prote cted 1 o n the enclosed side as r equired for one-hour fire-resistive construction. Sec. 330S(m) / E. Minimum construction specifications shall be made a part of the approved plans ............... (See attachedl \M U;? o 't4 YL '"'_tJS, l ROOFING '-----'----' ~ Specify roof pitch. //Roof pitch is not adequate for roof type / specified. Specify minimum pitch of ____ _ /.. Specify roof material and application. 'Jo<.' Specify I.C.B .O. approval number for roof /--materials not covered in UBC. _,;,<. Specify roof slope for drainage or des:gn ~o support accumulated water. Sec. 3207(a) d-Show roof drains and overflows. Sec. 3207(a) / Provide skylight details to show compliance with Sections 3401 and S207 or provide ICBO approva 1 number. ~~ ~ ) O , J . ,..., ~rovide plastic roof panel details to show ff. compliance with Section 5206 or provide ICBO number . Show attic ventilation. Minimum vent area is l /150 of attic area or l /300 of attice area if at least SO\ of the required vent is at least 3 feet above ceiling joists. Sec. 3205(c) MASONRY ✓.'Provide fireplace construction details or / note construction to be per attached fireplace A andard drawing . Sec. 3707 ow veneer support and connections comply th Sec. 3002, 4 ,5 ,6, and Sec. 2516(a) regarding ties and #9 wire in horizontal joints or note construction to be perattached sheets 30-1 or 30-2. ✓ Show height and construction details of /Y• all masonry walls. Chapter 24 89 . Note that cleanout openings shall be· provided at the bottom of all cells to be grout fill ed o ver 4' in a single pour. Cl e ano ut s hall ,.. , ,,,8 2 • be sealed before grouting, after inspection. Sec. 2415 Show floor and roof connections to masonry walls. Connectio n shdll resist 200 pounds per lineal foot or the actual design load, ~hichever is greater. Sec. 2310 Provide material specifications for mortar, grout, masonry and reinforcing steel. Sec. 2403 ✓ Show how masonry house walls retaining earth 1/:re to be waterproofed. Provide detail. Note that special inspection of the maso nry will be required for _____________ _ G. GARAGE ANO CARPORTS .>,-PO.Garage requires one-hour fire pro tection _,.. o n the garage side of walls and ceilings common to the dwelling. Table 5-B Sec.SOJ(b) .A ll eJe~~ suppor,ing floor wve gara~ /"' ;"'on'av~ o~e-hou: fi:e-res!sti~ protect ion ~ ~ 1 on the 9a~age side. Sec. SO 3. Oeams and 'J\ posts, not within the wal l o r ce1l1ng co n- \ struction , must comply with UBC, Table 4 3-A , ( 1 · • \ 1 o r be minimum 6 • d imension beam and m1n1mum :, 1, 8 " b' 8 " post. ''-' \ -"'("\ I • \ I c:' ..--.. '(%' • . Show 1 3/8" solid core self-closing door for openings between garage and dwelling. Sec. 503(d) 1,...8".l. Garages are not permitted to open into / ~ r oom used for s leeping purposes. Sec. 1104 y><. Openings between carport and residence / require sel f-closing doors and stationary windows. Sec. 1214 '~Show garage framing section, s ize of header r·· over garage opening, lateral cross bracing at pl ate line and method of bracing garage front. Chapter 23 NOTE: Minimum plywood diaphragm ratio is 3 1/2 to l or 2'8". Table 24-I 1~ Doors between d wellings and attached garages ./ may swing in either direction provided the difference in floor elevation between the dwel ling and garage does not exceed 7 1/2 inches and provided the door is not used as the primary means of egress from the building. If the difference in floor elevation exceeds 7 1/2 inches, or if the door is used as the primary means of egress from the building, additional steps o r landing must be provided in accordance with stairway requirements, and the door must not swing over the depressed level. (see 3303( i)2 and 3305 (g). Provide 18" raised platforms for any FAU, water heater, or any other device which .may generate a flame or spark. ~ Note that continuous fire wall protection ✓-· shall be installed behind raised p latform(s) prior to framing platform. H. ,FOUNDATION REQUIREMENTS ~ Note on plans that"A soils engineer shall / eva1uate any unanticipated uncompacted fi l l or expansive soil or other soil problems A isclosed during construction". Sec.306(al12. ubmit soils classification determination ya licensed e ngineer or a rchitect based on obser vation, tests, borings, or excavations, and containing comments on the degree of e xpansiveness, compr essibility and bearing /~lue. Sec. 2905 >-21"· Note on the plan the soils classification, / whether o r not the soil is expansive, and note t he a l lowab le bearing value . Sec. 2905 l22. The foundation plan does not comply with the soil report recommendat ion for this project ____________________ _ l~Provide notes on the foundation plan listing / the soils repor t recommendations for foundations. slab and building pad preparation. Note on the foundation plan that "Pr ior to the Contractor requesting a Building Department foundation inspection, the soils engineer shall advise the Building Official in writing that: 1. the building pad was prepar ed in accor- dance with the soil s report: 2. the utility trenches have been properly backfilled and compacted, and: 3. the foundation excavations, forming and reinforcement c omply with t he soils report and appro ve d plan." 12-6 . ....-Provide spr ead footing s for concent r ated ' l oads de stgned for I ,000 PSF sot l bearing or per bea r tng va lue as determined by an engineer o r 3 r c hitcct. Ch~pt er 29 p( Show height of all foundation walls. Chapter 23 'y. Show height of retained earth on all foundation walls. Chapter 23 i/4 Show distance of foundation to edge of /•v• cut or fill slopes and show steepness and heights of cuts and fills. Chapter 29 12'1". :)lote on plans that wood shall be 6" above 7 · · finish grade. Sec. 24l 7 (c) 7. Note on plans that surface water will drain away from building and show drainage pattern and key elevations . Sec. 2905(fl Dimension foundation per Table 29A. TABLE NO. 29-A-FOUNDATIONS FOR STUD BEARING WALLS-MINIMUM REQUIREMENTS Dr,TH or FOUNDATION WIDTH THICKNESS IUOW NUMIEII TNICllNUS Of o, OF NATUUL OF FOUNDATION WALL FOOTING FOOTING SUIIFAC[ STOIIIU (IIICbtl) (lnchtsJ (lnchtsl OF CIIOUND AND FINISH CONCIICTE UNIT CIIAOE MASONIIY (Inches) >---· -- l 6 6 12 6 12 2 8 8 15 7 18 3 10 10 18 8 24 ~OTES: \Vhett unusu:Ll condition., or frost conditions are found, footU'\gs an<l foundations shnll h• as r<(luirtd in S<etion 2907 1a ). The ground undtr the floor may be-e-xcavate-d to th(' t·lt-\·:lt1on of tht· lop of the footioc:. Show foundation sills to be pressure treated, or equal. Sec. 2517(c) 3. Show foundation bolt size and spacing. Sec. 2907(el l ~ecify size, ICBC number and manufacturer ~--~£power driven pins. Show edge and end how size, imbedment and location of hold A istance and spacing. Sec. 306(f) A n anchors on foundation plan. Sec. 2312(f) l . Note on plan that hold down anchors must be tied in place prior to foundation inspection. Sec. 2312(fl 1 7. Show adequate foot i ngs under al l s hear walls. Sec. 23ll!e l _1)<. Show stepped footings for slopes steeper / ~ than 1:10. Sec. 2907(cl -~ Show minimum 18" clearance from grade to / bottom of floor joists and minimum 12" clearance to bottom of girders. Sec. 2517 uef.'" Show pier size, spacing and depth into / undisturbed soil. Tabl e 29-A I l~ Show minimum under floor access of l8"x 24". Sec. 2517 .... Note cross bridging or blocking. Floor joists and rafters more than 12" in depth and spanning mor e than 8 fe et shall be supported laterally by bridging at intervals not exceeding 8 feet. Sec. 2506(g) Show blocking at ends and at supports of floor ·joists, and for rafters at exterior walls. Sec. 2506(gl Show solid blocking at ridge line and at exterior walls on trussed roofs. Sec. 2506(g) 165. Show double joists. Floor joists shall y6. ~- be doubled under bearing partitions running parallel with the joists. Sec. 2518(dl 5 Show rafter ties. Rafter ties shall be spaced not more than 4 feet on center where rafters and ceiling joists are not parall el . Sec. 2518(hl Show rafter purl i n braces to be not less than 45 degrees to the horizontal. Sec. 2518(hl Show 1/2" minimum clearance between top plate of interior partitions and bott om chord of trusses. (To ensure loading will be as designed.) Show double top plate with minimum 48" lap splice. Sec. 2518(gl4 Show nailing will be i n compliance with Table 25-P. Vl . Provide fire stops between stories, between r top story and roof space, at ceilings and floor l evels in interior and exterior walls, in mansard roof or eyebrow so no concealed or furred space is greater than 10' horizontally or vertically, between stair stringers at top and bottom and between studs along and in l ine with stair run adjoining stud walls and partitions, at perimeter of sliding door pockets, between chimney and wood frame using metal or incombustibles for the fire stop and at other places that could afford passage of flame. Sec. 25171fl ,✓ Show stud size and spacing. Maximum al l ow-7-· able stud heights: 2"x4"@ l6" is 14 '; 3"x4"&2"x6"@ l6"o.c. is 20 '. Sec. 25 18(g) 2 1 / Note an A.I.T.C. Certificate of Compliance .,.Y'· for glued laminated wood members shall be given t o t he Building r nspector prior to erecti on. Sec. J06 (f l Detail all post t o beam and post t o footing connections . Sec. 2517(c) 4 Specify natl size and spacing for all shear walls, floor and roof diaphragms. Indicate required blocking. Maintain maximum diaphragm dimens i o n ratios. I Tables [,J,K). Show J"x4" or 2"x6" studs in first story of three story building. Sec. 2518(f) ty.Show minimum under floor ventilation equal / to l 1/2 sq . ft. for each 25 lineal feet of exterior foundation with openings as /77. Provide truss details and t russ calculations. ·_ A Provide roof framing plan. Sec. 302 (a )7 ~ Provide framing sections through ~yJ fl•~l~g f°{?.bN,\;f 1\ (' • ,-: 'I ,,·.:... 1 i...!..\\ 1 \~.....> . I. 6 l. / close to corners as practicable to provide cross ventilation o n at least two approximate- ly opposite sides. Sec. 2517 FRAMING Section 302(al 7 (:f-/l'" .. 11 1J C,r -m,v~!: l.,..u,\ 0 ", ,-\l. P. ,.; S r-~'l 1 ll 1.::--0 '7 ~ Specify all header sizes for opening over • 4' wide . Sec. 2518(gl 7 Show all joists, rafters , beams, and posts 2" to 4" thick to be No. 2 Grade Douglas Fir-Larch or better. All posts and beams 5" and thic ker s hall be No. 1 Grade Douglas Fir-Larch or better. (Table 25-A-l l ~ Provide calculati ons for 4 '>(.\ "2-, ~e"" ~ H:e:!,V(;:;'1 7, tt nn., C:,\(.1 4 P,.;>.), ~T Show wall bracing. Every exterior wood stud wall and main c ross partiti on shal l be braced at e ach e nd and at le ast every 25 feet of length with lx4 diagona l let-1n brace or equivalent . Sec. 2518(q)S Section J02(a l 7 , ,-, In are as sub ject to wate r splash and in e xte r ior l oca t i o ns , wood c olumns and posts shall be supported by pie r s projecting at least 2" above the f ini shed grade and s hall bea r on a metal base p lat e or tre ated wood unless t he columns or pos t s are foun- dation gra de redwood or cedar. Sec . 251 7(c l 4 l~Show location of attic access with minimun s ·ze 22" x 30". Sec. 3205 ow draft separation for attic areas 1~ excess of 3,000 sq.ft. Sec. 3205 y."show draft separation for space between dropped ceilings and floor above in excess of l ,000 sq.ft. Sec. 2517 }'8( ecify plywood grade a nd panel i ndenti- cation index. Table 25-J hen roof pitch is less than 3:12, design ridge as a oeam. Sec. 2518 (hl ,..,.,...---wood shear walls shall not be used to 7". ~esist horizontal forces contributed by masonry in buildings over one story in A eight. Sec. 2516(b) Gypsum lath and plaster, gypsum s heathing board and gypsum wallboard shall not be used 1n vertical diaphragms to resist forces imposed by masonry or concrete construction. Table 47-I fa If cripple wall studs are less than 14", ~aming shall be solid blocking. Sec.2518(g)6 Cripple wall studs exceeding 4 feet in height shall be 3 inch by 4 inch or 2 . inches by 6 inches when supporting 2 s tories. Sec. 2518(gl6 Show plywood sheathing over exposed eaves, or other weather exposed areas, is exterior grade. Sec. 2517(gJ 3 ,/Showa weep screed at the foundation plate 7·· line on all exterior stud walls to be uccoed. Sec. 4706(e) ovide an approved waterproof building per under wood siding. Sec. l70l(a) ~ Show access to the attic or under floor furnace to be minimum 30 inches by 30 inches. Sec. 708, 709 UMC ,,_/Note that passageway to the attic furnace ,7'" ~hall be unobstru~ted and have continuous solid flooring not less than 24 inches wide. Sec 708 UMC v~: Show permanent electrical outlet and / lighting fixture controlled by a switch for the attic furnace. Sec. 708 UMC u f-show details to comply with Section qo9 ./ for furnace under the floor, Section 708 for attic furnace, or Section 710 for /.of or outside furnace. 2~. Note on plan, gas vents and non-combustible / piping passing through three floors or less shall be effectively draft stopped at each floor or ceiling. UBC Sec. l706(a)6 IL ELECTRICAL (National Electrical Code) All wiring shall comply with the National Electrical Code 7 Note.on the plan the amperage of e l ectrical ervi ce. _J_ the electrical installation is ~ore than 200 amperes, show panel location and provide a single line diagram and load calculations including: a. Wiring method employed. b. Sizes of all conductors, switches, c . d. e. circuit breakers, fuses, and conduits. Approximate length of service feeders. Provide plot plan showing services, all panel locations, circuit arrangement and load distribution on panel busses. Provide typical panel schedule(s J. 195. Specify an approved flashing for exterior openings and parapet walls. Sec. 3208 ,✓ Show corridor width to be minimum 36". ✓-~ec . 3304(bl JJ"'· :pecify truss layout for 30" x 30" attic ~ ;tr~ 5- . Y'· Dwellings require minimum 100 amp service. Show location of all electrical receptacles. Electrical receptacle locations and/or spacing is not adequate in NQ.u.., CI\ '.B \IVGJ": l"t.e c.o..i, ¼>A . access. Ridges, hips, and valleys shall be at least one size larger than supported Y9· rafters. Sec. 2518(h) 3 Provide metal straps across ridge beam and rafters. J. MECHANICAL All heating, ventilating, and cooling systems and appliances shall comply with the Uniform Me~ical Code. _.)-61)-~how the s ize, location and type of all heating and cooling appliances or systems. ,o.-<r""' Show source of combustion air for furnace 7•· will comply with Chaper 6, U.M.C. y-1. At least o ne receptacle shall be installed outdoors, in basements and attached garages, other than laundry outlets. Art. 210-25(b) Show minimum dwelling lighting (NEC Art. 210-26(a) and GFI'S in garage, baths and outdoors. NEC Art. 210-8(a). Note "LIFER" ground to be provided (NEC). Art. 250-81 PLUMBING (Uniform Plumbing Code) All plumbing shall comply with the Unifrom Plumbing Code. 236. t,;;')_ .~very dwelling unit shall be provided with ~,h\iheating facilities capable of maintain- ,i..,;J) ,~· ing a room temperature of 70° F. at 3 ,-r1:.>1 .I feet above the floor in all habitable .fi· Show water heater size, type and l ocation on plans. Show method of providing combustion air to fuel burning water heater. Sec. 1307 \~ ,t}) 1rooms. Show basis for compliance. UBC f/1 • Sec. 1211 ~ •• Show minimum 30" deep unobstructed working 20~. space in front of furnace . Note on plans.clearances to be turers listing. Sec. 704 UMC per manufac- Furnace shall not be installed under any stairway. Sec. 704 UMC Furnace shall not be installed in any bedroom, bathroom, closet, or 1n confined space wit h access o nly t hrough such room, ~nless spe c 1f 1ed as direct vent appliance, ~nclosea furnace o r e l ectric heating appliance. Sec. 70 4 .JMC 2])1. Show ICBO approval for prefab fireplace and provide approved installation instructions at )Ob site. 238. / r· Fuel combustion water heater shall not be installed in bath or bedroom or in a closet opening into bath o r bedroom. Sec. 1309 Provide adequate barrier to protect water heater from vehicle damage. Sec. 1110 Show T and P val ve on water heater and show route of discharge line to exterior Sec. 1007(e) Provi de dryer vent to outside. Sec. 1903 UMC Note on t he plan that hose bibbs and lawn sprinkler s ystems s hall have approved backflow p r e vent i o n dev ices. Sec . 1003 Shower s tal l shal l accomodat e a 30"c 1rcle and have a m1n1mum f l oor area of 900 sq.i n. UPC 909(d l !!..:_ fiOISE INSULATION (DUPLEXES) ~-~how details of duplex common (party) wa l ls and floor/ceiling assemblies to achieve a Sound Transmission Class (STC) rating in walls of 50 decibles a nd an Impact Insulation Class (IIC) rating on floor/ eiling of 50 decibles. Title 25 how how pe netrat ion of assemblies for piping, electrical devices, recessed cabinets, bathtubs, soffits, or heating ventilating, or exhaust ducts shall be sealed, lined, A insulated to maintain required sound ransmission rating. Titre 25 rovide insulation i n walls and ceiling to achieve STC of 50 between garage and living area if garage use is not controlled by resident Title 25. NERGY CONSERVATION 11 addi tions to existing residential uildings must comply with Title 24 energy regulations. Additions exceeding 30\ of the exist ing building requires t he existing and addition to have R-19 ce iling insulation if the existing c eiling area is accessible for insulation installation a20-l40l (cl. ,/Specify the insulation R valves for walls, r· roof and ceiling. (R-11 for walls: R-19 for ceilings, or provide details and analysis or alternate design. T20-1403 Table A & 28. pecify the gross floor area or heated portions of the dwelling, and the area • f glazed openings on the plan. (T20-l430l rovide an analysis justifying i ncreasing he single glazed area beyond 161 of the gross floor area. Show method to reduce heat loss to that which would occur with basic glazing. (T20-l402,def.l 21✓.-'Provide energy analysis to show that the ✓-bonnet capa cit y of the gas central furnace does not exceed the building design heat loss by more than 301. (Exceptions : 48,000 BTU Hr. output furnace. See also Ca lifornia Efficiency Adj ustment.) T24-1404 Note on plan that all tranverse ducts, plenums, and fitting joints of HVAC system s hall be s ealed with pressure sensitive tape or mastic to prevent air loss. T20-1404 Note on plan that insulation of ducts shall conform to UMC Section 1005. (T20-l404l Note on p lan that all doors and windows to the exterior or to unconditioned areas shall be fully weather striped per ANSI Standard. (T20-l403). . Note on plan that back draft dampers are required on all fan sys t ems exhausting ;/ air from the building. T20-1403 Electrical resistance space heating shall not be used unless: a. 60\ of heating/cooling is supplied by a nondepletabl e source. b. supplements a heat pump system. c . less than 10\ of total heating system. d . life cycle cost analysis justifies. /. T20-l404 Note on plan that all heating and cooling equipment efficiencies shall confo rm to Title 20-Chapter 2, Subchapter 4, Article 4. (75\ tor forced air furnaces). /' Note on plan that no natural gas, centr al heating plant may be installed without _ /an Intermittent Ignition Device. T20-1 405 ,J. Electric resistance water heating is not permitted unless verfied as cost effective by a life cycle cost anal ysis. T20-1406 ~ Outdoor pools with fossil fuel heaters require pool covers as well as other energy saving devices such as time clocks, etc. T20-1406 MISCELLANEOUS Show a minimum 2" air space and f l ashi ng between planter and building walls. Sec. 2517(e) Specify material to be used under the shower tile. Sec. l707(a) Specify· lath and plaster to comply with Chapter 47, UBC. Two 3/4" copper pipes must be installed from water heater location to co nvenient location of future solar panels (City Ord.) Provide sleeves (roof jacks) in roof for t future 3/4" copper pipes to cvnvenient ation of future solar panels (City Ord.) e that solar water piping is to be insulated in areas that are not heated or cooled. (City Ord. l See attachment for roofing requirements. The plans were reviewed based on the information shown on the plans. If the plans are in error, or changed during cons truction, the permittee shall contact the Building Department for review and prior approval before proceeding with the work: 0 Building plans are substantially correct and complete. By: ________________ _ Date: __________________ _ 0 Building plans would be substantially correct and complete if mino r corrections are made at counter. By: ________________ _ Da te: __________________ _ Building plans require major corrections and complete plan recheck, by plan check ed. If you have any questions regarding this plan check, please call ___________________ at _________ _ We ..,ould also be pleased to meet with you, at no charge, if additional assistance is needed. " I ·' / D APPLICANT COPY _fr~~\C..AvJT' ·, ~ ~L~ fhl.e q()\-~'\ t ~ I e't-e . \{e,,~~--:a~~C~IT~Y:"""".c~O~P~Y----> \&015C) ··.,.IS. L.\S.I ,-,,v.Q A9.D 'D'1',A-, Co~ ~I....E'l"G' D PLAN CHECKER COPY µcv' UJIU...P.:,e l'Yl jl\-0&" l'\-FiE1'2 61 1 )~II , \.?.ec t>' P" Qtitp of Qtarl~bab , · ~ (:-~. Cl1'\.LuL,flrl10 ll)..!S. t\-fl.E'" 1Z~1 llt;U TO <9-vt Su ta?, ~ I ~ Tl fl-Ct a.o::)'~ d:::::. 1 C 1+1 W1 r\iQ(.J . .Su~fc)12,f o~1 So\l .... '3!2.&, t(J1it,,n I 52'.o tt--/rl,J L14=r"ct2AL f\-09.QUAGL,fJ COYiY)e.diCll1S I o..,;k., .'P~ \? \1.{) \,)I \)Q CoJ UJL.14-11 6t'U~ 6:, ..,-0 D rt, C\ I tJ D 8if\ 1 L..S. , s . Submit fully dimensioned plot plan drawn to scale showing l oc3tion size, and use of all existing and proposed structures on the lot. Identify property lines and show lot dimensions and all easements. Show location of all cut or fill slopes and approximate finish floor elevations for all structures and show e l e vations at a ll corners. Sec. 302(b)7. Indi cate distance from cente r-line of street or alley to property line and distance from c urh to property line. Sec. 302(b)7 JURISD ICTION: CY-h'U-51bA:;O DATF. 5'\':\\ ~z., PROJECT ADDRESS: "Z 44-o S.:::rrzoM al.:::~-G\ ,i..u..e-~. Plans, specifications and calculations shall be s igned by a California State licensed e ngineer or architect. (California P.'ltf! plans ~ate plans received by plan checkerc:'-"-La...=.....;;:=--t-- Date i nitial plan check completed f 12,. \ by~ fOREWClRD: PLEASE READ 1:5'\"\ 0 lan check is limited to technical requirements contained in the Uniform Building Code, Uniform ?l umb1ng Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped. The plan check is based on regulations enforced by the Building Inspection De par tment. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department o r other departments. The ite ms circled below need c larification, modification or change. All circled items have t o be s atisfied before the plans will be in conformance with the cited codes and regulations. Pe r Sec. 303 (c), 1979 Uniform Building Code, the approval of the plans does not permit the v iolat i o n of any state, county or city law. I . Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returne d to you by the jurisdiction, to: ~-To facilitate rechecking, pl ease ide ntify, next to each circled item, the sheet of the plans upon which each correction on t his sheet has been made and return this check sheet with the revised plans . Indicate on plans the name of the l e gal owner and name of person responsible for t he prepara tion of the p lans. Sec. 302(b) Business and Professions Code ) n . FIR~ PROTF.CTION 12 . Walls closer than 3 feet to property lines shall be one-hour fire-rated construction, have no openings, and shall have 30 inch parapets when the building floor area exceeds 1,000 square feet on any floor. (Table 5-A Sec. l 709(a) 13. Projections, including eaves, may not extend more than 12 inches into the 3 foot setback from the property line . Sec. 1710 and Sec. 5041b) 14. Projections, inc luding eaves,shall be one- hour fire-r esistive construction, heavy timber or of non-combustible material if they project into the 3 ' setback area from the prope rty line. Sec. 1710 I ,. Show l ocation of p.:-rn1,1ne ntl y wircd smoke d~t c c tor. Sec. 1210 C ~--ROOM SIZES, l,IGHT, VF.NTILI\TIONS ANO GLI\ZIN<l ~~. One room must contain a mi n imum of 150 square feet of superficial floor area, Sec. 1207(b) 2r,. ll11hi table r ooms, oth,,r than kitchens, shall contain at least 70 squar e feet o f floor area. Sec. l 2 O 7 ( b) 27. ~indow a r ea must teat l east l/10 of the floor area and a mi nimum of 10 square feet per Sec. l207(a). Appears to be deficient in 28. Openable window area must be 1/20 of the f loor area and a mi nimum of 5 square feet. In bathrooms , laundrv rooms and similar rooms. Minimum i s 1:s sq.ft. (Sec.l205(a) 29. One-half of a ll required window area must be openable in 30. Provide mechanical ventil ation capable of providing five air changes per hour in bathrooms, water closet compartments, laundry rooms and similar r ooms if required windows are not provided. Sec. 12051a) 31. No habitable room, other t han a kitchen, shall be less than 7'0" in any dimension. Sec. l207(c) 12. Show that ceiling heigh t for habitable rooms is a minimum of 7'6". Sec. l207(a) . ' 3 3. 34. 35. 36. 37. 38. 39. 40. Show ceiling height for laundry rooms, hallways, corridors, and bathrooms is a minimum of 7'0". Sec. 1207(a) Provide 30" clear width for water closet compartments and 24" clearance in front of water closet. Sec. 17ll(b) No cooking room shall be used for sleeping purposes, unless complying as an efficiency living unit. Sec. 1208 Specify safety glazing for glazing in hazardous locations such as glass doors, glazing adjacent to such doors and glazing adjacent to walking surfaces. Sec. 5406 Glazing in shower and tub enclosures (including windows) shall be tempered, laminated or approved plastic. Sec. 1711 (fl(gl Sleeping rooms shall have a window or exterior door for emergency exit. Sill height shall not exceed 44n above the floor. The window must have an openable area of at least 5.7 square feet with the minimum openable width 20n and the minimum openable height 24n. Sec. 1204 Eaves and cornices may not project into a required yard more than 2 inches for each foot of yard width if required windows open into the yard. Sec. l206(dl A mezzanine is an intermediate floor and may not have a floor area exceeding 33 1/3 percent of the total floor area in the room below, and the mezzanine floor must have a clear height of 7 feet, above and below,and must have 65\ of the long side open to the room below. 41. The loft you show does not comply as a mezzanine floor and is, by Building Code definition, a story ______________ _ D. EXITS, STAIRWAYS, AND RAILINGS 45. Floors above the second story shall have not less than 2 exits. Sec. 3302(a) 46. Required exit doorways shall be not less than 36" in width and not less than 6'-8" in height, and shall be capable of opening at least 90 degrees. Sec. 3J03fel 47. Provide 36" high protective railing for porches, balconies, and open sides of landings. Maximum opening between railings shall be less than 9". Sec. 1716 48. Show how guardrail connection details are adequate to support 20 pounds per lineal foot at a right angle to the top rail. Table 23-B 49. Provide stairway and landing details. Sec. 3305(bl & (c) a. Maximum rise 8• and minimum run is 9". b. Minimum head room is 6'-6". c. Minimum width is JO". 50. Handrails shall satisfy the following: a. Provide handrail for stairways over 30• high when serving a single dwelling. Title 24, Sec. T25-22(b) b. Handrail shall be 30• to 34" above the nosing of treads. Sec. 330S(j) c. Handrail projecting from a wall shall have a space not less than 1 1/2" between the wall and the handrail. The hand grip portion of handrail shall be not less than l 1 / 4" nor more than 2" in cross-sectional ,dimension. Sec. 330S(jl (see attached) 51. Every stairway landing shall have a dimension, measured in the direction of· travel, at least equal to the stairway width. Sec. 3305{g) 52. A door may open over a stairway landing provided the door, in any position, does not reduce the clear area of the landing, in the direction of stairway travel, to less than one-half the required width of the stairway. Sec. 3305(g) 53. A door may open inward at the top step of a stairway provided the top step is not more than 7 1/2• lower than the floor level. Sec. 3303(i)2 54. Provide details of winding stairway. a. Minimum tread is 6 inches at any point and minimum 9 inches at a point 12 inches from the side of the stairway. b. Maximum rise is 9 inches. c. Minimum width is 30 inches. Sec. 3305(d) (see attached) 55. Provide spiral stairway details: 56. 57. 58. 59. a. Minimum run is 7 1/2 inches at a point from where the tread is the narrowest. b. Maximum rise is 9 1/2 inches. c. Minimum headroom is 6 feet 6 inches. Sec. 3305(f) (see attached) Sprial stairways may not be used for required exits when the area served is greater than 400 sq. ft. Sec. 3305(fl Spiral stairways must have a clear walking space of 26 inches between the column and handrail. Sec. 330S(f) Provide I.C.B.0. Reasearch Report and Number for metal stairway, or submit plans and calculations and approved fabricator registered with the Building Department or note that the stairway fabrication shall be done under special inspection per the approved fabrication plans. Sec. 306(a)4B and Sec. 306(fl In buildings over 2 stories in height, provide 3/4 hour fire-rated assemblies for all openings in the exterior wall below or within 10 feet horizontally of an exterior stair- way. An exit balcony with 2 separated stairways is exP.mpt. Sec. 3305 60. Exterior stairways shall not project into the 3 foot setback from the property lines. Sec. 3305(n) . ; 61. The walls and soffits of the enclosed useable space under interior stairs shall be protected on the enclosed side as required for one-hour fire-resistive construction. Sec. 330S(m) 62. Minimum construction specifications shall be made a part of the approved plans. (See attached) B. ROOFING 70. Specify roof pitch. 71. Roof pitch is not adequate for roof type specified. Specify minimum pitch of _____ _ 72. Specify roof material and application. 73. Specify r.c.e.o. approval number for roof materials not covered in USC. 74. Specify roof slope for drainage or design to support accumulated water. Sec. 3207(a) 75. Show roof drains and overflows. Sec. 3207(~) 76. ?rovide skylight details to show compliance with Sections 3401 and 5207 or provide ICBC approval number. 77. Provide plastic roof panel details to show compliance with Section 5206 or provide ICBC number. 78. Show attic ventilation. Minimum vent area is l/150 of attic area or l/300 of attice area if at least 50% of the required vent is at least 3 feet above ceiling joists. Sec. 3205(c) 8. MASONRY 85. Provide fireplace construction details or note construction to be per attached fireplace standard drawing. Sec. 3707 86, Show veneer support and connections comply with sec. 3002, 4,5,6, and Sec. 25l6(al regarding ties and #9 wire in horizontal joints or note construction to be per attached sheets 30-1 or 30-2. 88. Show height and construction details of all masonry walls. Chapter 24 89. Note that cleanout openings shall be·provided at the bottom of all cells to be grout filled over 4' in a single pour. Cleanout shall be sealed before grouting, after inspection. Sec. 241S 91. Show floor and roof connections to masonry walls. Connection shall resist 200 pounds per lineal foot or the actual design load, whichever is greater. Sec. 2310 92. Provide material specifications for mortar, grout, masonry and reinforcing steel. Sec. 2403 93. Show how masonry house walls retairiing earth are to be waterproofed. Provide detail. 94. Note that special inspection of the masonry will be required for _____________ _ G. GARAGE AND CARPORTS 100.Garage requires one-hour fire protection on the garage side of walls and ceilings common to the dwelling. Table 5-B Sec.503{b) 101,All elements supporting floor above garage to have one-hour fire-resistive protection on the garage side, Sec. 503. Beams and posts, not within the wall or ceiling con- struction, must comply with uec, Table 43-A, or be minimum 6" dimension beam and minimum 8" by 8" post. 102. Show l 3/8" solid core self-closing door for openings between garage and dwelling. Sec. 503(d) 103. Garages are not permitted to open into a room used for sleeping purposes. Sec. 1104 104. Openings between carport and residence require self-closing doors and stationary windows. Sec. 1214 105. Show garage framing section, size of header over garage opening, lateral cross bracing at plate line and method of bracing garage front. Chapter 23 NOTE: Minimum plywood diaphragm ratio is 3 1/2 to l or 2' 8". Table 24-I 106. Doors between dwellings and attached garages may swing in either direction provided the difference in floor elevation between the dwelling and garage does not exceed 7 1/2 inches and provided the door is not used as the primary means of egress from the building. If the difference in floor elevation exceeds 7 1/2 inches, or if the door is used as the primary means of egress from the building, additional steps or landing must be provided in accordance with stairway requirements, and the door must not swing over the depressed level. {see 3303(il2 and 3305 (g). 108. Provide 18" raised platforms for any FAU, water heater, or any other device which may generate a flame or spark. 109. Note that continuous fire wall protection shall be installed behind raised platform(sl prior to framing platform. ff. FOUNDATION REQUIREMENTS 119. Note on plans that"A soils engineer shall eva-luate any unanticipated uncompacted fill or expansive soil or other soil problems disclosed during construction". Sec.306(a)l2. 120. Submit soils classification determination by a licensed engineer or architect based on observation, tests, borings, or excavations, and containing comments on the degree of expansiveness, compressibility and bearing value. Sec. 2905 121. Note on the plan the soils classification, whether or not the soil is expansive, and note the allowable bearing value. Sec. 2905 122. The foundation plan does not comply with the soil report recommendation for this project · 123. Provide notes on the foundation plan listing the soils report recommendations for foundations. slab and building pad preparation. 124. Note on the foundation plan that "Prior to the Contractor requesting a Building Department foundation inspection, the soils engineer shall advise the Building Official in writing that: 1. the building pad was prepared in accor- dance with the soils report: 2. the utility trenches have been properly backfilled and compacted, and: 3. the foundation excavations, forming and reinforcement comply with the soils report and approved plan." 125. Provide spread footings for concentrated loads designed for 1,000 PSF soil bearing or per bearing value as determined by an engineer or architect. Chapter 29 ' 126. Show height of all foundation walls. Chapter 23 127. Show height of retained earth on all foundation walls. Chapter 23 128. Show distance of foundation cut or fill slopes and show heights of cuts and fills. to edge at steepness and Chapter 29 129. Note on plans that wood shall be 6" above finish grade. Sec. 2417(c) 7. 130. Note on plans that surface water will drain away from building and show drainage pattern and key elevations. Sec. 2905{£) 131. Dimension. foundation per Table 29A. TABLE NO. 29-A-FOUNDATIONS FOR STUD BEARING WALLS-MINIMUM REQUIREMENTS DEPTN OF FOUNOAflON WIDTH THICKNESS BELOW NUMIH THICKNESS OF OF OF NATURAL OF FOUNDATION WALL FOOTING FOOTING SURFACE STORIES (lncllles) (lnclles) (lncflH) OF CROUND lND FINISH CONCRETE UNIT HADE MASONRY (Inches) I 6 6 12 6 12 2 8 8 15 7 18 3 10 10 18 8 24 XOTES: \Vhere unusual condition., or frost conditions are found. footings and foundations shall be as re-quire-d in Section 2907 (a). Thie !(round under thie floor may be e•cavate-d to the t-levation of tht- top of the footinQ:. 132. Show foundation sills to be pressure treated, or equal. Sec. 2517(cl 3. 133. Show foundation bolt size and spacing. Sec. 2907(el 134. Specify size, ICBC number and manufacturer of power driven pins. Show edge and end distance and spacing. Sec. 306(£) 135. Show size, imbedment and location of hold down anchors on foundation plan. Sec. 2312(f) 136. Note on plan that hold down anchors must be tied in place prior to foundation inspection. Sac. 2312(fl 137. Show adequate footings under all shear walls. Sec. 23ll(el 13~. Show stepped footings for slopes steeper than 1:10. Sec. 2907(c) 139. Show minimum 18" clearance from grade to bottom of floor joists and minimum 12" clearance to bottom of girders. Sec. 2517 140. Show pier size, spacing and depth into undisturbed soil. Table 29-A 141. Show minimum under floor access of 18"x 24". sec. 2517 142. Show minimum under floor ventilation equal to l 1/2 sq. ft. for each 25 lineal feet of exterior foundation with openings as close to corners as practicable to provide cross ventilation on at least two approximate- ly opposite sides. Sec. 2517 I. FRAMING 160. Show all joists, rafters, beams, and posts 2" to 4" thick to be No. 2 Grade Douglas Fir-Larch or better. All posts and beams 5" and thicker shall be No. 1 Grade Douglas Fir-Larch or better. (Table 25-A-l) 161. Show wall bracing. Every exterior wood stud wall and main cross partition shall be braced at each end and at least every 25 feet of length with lx4 diagonal let-in brace or equivalent. Sec. 2518(gl5 162. Note cross bridging or blocking. Floor joists and rafters more than 12" in depth and spanning more than 8 feet shall be supported laterally by bridging at intervals not exceeding 8 feet. Sec. 2506(g) 163. Show blocking at ends and at supports of floor joists, and for rafters at exterior walls. Sec. 2506(gl 164. Show solid blocking at ridge line and at exterior walls on trussed roofs. Sec. 2506(g) 165. Show double joists. Floor joists shall be doubled under bearing partitions running parallel with the joists. Sec. 2518(dl S 166. Show rafter ties. Rafter ties shall be spaced not more than 4 feet on center where rafters and ceiling joists are not parallel. Sec. 2518(h) 167. Show rafter purlin braces to be not less than 45 degrees to the horizontal. Sec. 2518(h) 168. Show 1/2" minimum clearance between top plate of interior partitions and bottom chord of trusses. (To ensure loading will be as designed.) 169. Show double top plate with minimum 48" lap splice. Sec. 2518(gl4 170. Show nailing will be in compliance with Table 25-P. 171. Provide fire stops between stories, between top story and roof space, at ceilings and floor levels in interior and exterior walls, in mansard roof or eyebrow so no concealed or furred space is greater than 10' horizontally or vertically, between stair stringers at top and bottom and between studs along and in line with stair run adjoining stud walls and partitions, at perimeter of sliding door pockets, between chimney and wood frame using metal or incombustibles for the fire stop and at other places that could afford passage of flame. Sec. 2517(f) 172. Show stud size and spacing. Maximum allow- able stud heights: 2"x4"@ 16" is 14'; 3"x4"&2"x6"@ 16"o.c. is 20'. Sec. 2518(gl2 173. Note an A.I.T.C. Certificate of Compliance for glued laminated wood members shall be given to the Building Inspector prior to erection. Sec. 306(f) 174. Detail all post to beam and post to footing connections. Sec. 2517(c) 4 175. Specify nail size and spacing for all shear walls, floor and roof diaphragms. Indicate required blocking. Maintain maximum diaphragm dimension ratios. (Tables I,J,K). 176. Show 3"x4" or 2"x6" studs in first story of three story building. Sec. 2518{fl 177. Provide truss details and truss calculations. 178. Provide roof framing plan. Sec. 302(a)7 179. Provide framing sections through ______ _ Section 302(a) 7 180. Specify all header sizes for opening over 4' wide. Sec. 2518{gl 7 181. Provide calculations for __________ _ Section 302(a) 7 182, In areas subject to water splash and in exterior locations, wood columns and posts shall be supported by piers projecting at least 2" above the finished grade and shall bear on a metal base plate or treated wood unless the columns or posts are foun- dation grade redwood or cedar. Sec. 2517(c)4 183. Show location of attic access with minimun size 22" x 30". Sec. 3205 184. Shaw draft separation for attic areas in excess of 3,000 sq.ft. Sec. 3205 185. Show draft separation. for space between dropped ceilings and floor above in excess of 1,000 sq.ft. Sec. 2517 186. Specify plywood grade and panel indenti- fication index. Table 25-J 187. When roof pitch is less than 3:12, design ridge as a beam. Sec. 2518 (hl 188. Wood shear walls shall not be used to resist horizontal forces contributed by masonry in buildings over one story in height. Sec. 2516(b) 189. Gypsum lath and plaster, gypsum sheathing board and gypsum wallboard shall not be used in vertical diaphragms to resist forces imposed by masonry or concrete construction. Table 47-I 190. If cripple wall studs are less than 14", framing shall be solid blocking. Sec.2518(g)6 191. Cripple wall studs exceeding 4 feet in height shall be 3 inch by 4 inch or 2 inches by 6 inches when supporting 2 stories. Sec. 2518(g)6 192. Show plywood sheathing over exposed eaves, or other weather exposed areas, is exterior grade. Sec. 2517(g) 3 193. Show a weep screed at the foundation plate line on all exterior stud walls to be stuccoed. Sec. 4706(e) 194. Provide an approved waterproof building paper under wood siding. Sec. 170l(a) 195. Specify an approved flashing for exterior openings and parapet walls. Sec. 3208 196. Show corridor width to be minimum 36". Sec. 3304{bl 197. Specify truss layout for 30" x 30" attic access. 198. Ridges, hips, and valleys shall be at least one size larger than supported rafters. Sec. 2518{h) 3 199. Provide metal straps across ridge beam and rafters. J. MECHANICAL All heating, ventilating, and cooling systems and appliances shall comply with the Uniform Mechanical Code. 200. Show the size, location and type of all heating and cooling apPliances or systems. 201. Show source of combustion air for furnace will comply with Chaper 6, U.M.C. 202. Every dwelling unit shall be provided with heating facilities capable of maintain-ing a room temperature of 70g F. at 3 feet above the floor in all habitable rooms. Show basis for compliance. UBC Sec. 1211 203. Show minimum 30" deep unobstructed working space in front of furnace. 204. Note on plans,clearances to be per manufac- turers listing. sec. 704 UMC 205. Furnace shall not be installed under any stairway. Sec. 704 UMC 206. Furnace shall not be installed in any bedroom, bathroom, closet, or in confined space with access only through such room, unless specified as direct vent appliance, enclosed furnace or electric heating appliance. Sec. 704 UMC 207. Show ICBC approval for prefab fireplace and provide approved installation instructions at job site. 208. Show access to the attic or under floor furnace to be minimum 30 inches by 30 inches. Sec. 708 & 709 UMC 209. Note that passageway to the attic furnace shall be unobstructed and have continuous solid flooring not less than 24 inches wide. Sec 708 UMC 210. Show permanent electrical outlet and lighting fixture controlled by a switch for the attic furnace. Sec. 708 UMC 211. Show details to comply with Section ~09 for furnace under the floor, Section 708 for attic furnace, or Section 710 for roof or outside furnace. 212. Note on plan, gas vents and non-combustible piping passing through three floors or less shall be effectively draft stopped at each floor or ceiling. UBC Sec. 1706(al6 K. ELECTRICAL (National Electrical Code) All wiring shall comply with the National Electrical Code. 221. Note on the plan the amperage of electrical service. 222. If the electrical installation is more than 200 amperes, show panel location and provide a single line diagram and load calculations including: a. Wiring method employed. b. Sizes of all conductors, switches, circuit breakers, fuses, and conduits. c. ApprOximate length of service feeders. d. Provide plot plan sbowing services, all panel locations, circuit arrangement and load distribution on panel busses. e. Provide typical panel schedule(s). 223. Dwellings require minimum 100 amp service. 224 225. 226. 227. 228. Show location of all electrical receptacleg_ Electrical receptacle locations and/or spacing is not adequate in At least one receptacle shall be installed outdoors, in basements and attached garages, other than laundry outlets. Art. 210-25Cb) Show minimum dwelling lighting (NEC Art. 210-26(a) and GFI'S in garage, baths and outdoors. NEC Art. 210-8(al. Note "UFER" ground to be provided (NEC). Art. 250-81 PLUMBING (Uniform Plumbing Code) All plumbing shall comply with the Unifrom Plumbing Code. 236. Show water heater size, type and location on plans. 237. Show method of providing combustion air to fuel burning water heater. Sec. 1307 238. Fuel combustion water heater shall not be installed in bath or bedroom or in a closet opening into bath or bedroom. Sec. 1309 239. Provide adequate barrier to protect water heater from vehicle damage. Sec. 13~0 240. Show T and P valve on water heater and show route of discharge line to exterior Sec. 1007(e) 242. Provide dryer vent to outside. UMC Sec. 1903 243. Note on the plan that hose bibbs and lawn sprinkler systems shall have approved backflow prevention devices. Sec. 1003 244. Shower stall shall accomodate a 30"circle and have a minimum floor area of 900 sq.in. UPC 909(d) M. 260. 261. 262. .!!.,_ 271. NOISE INSULATION (DUPLEXES) Show details of duplex common (party) walls and floor/ceiling assemblies to achieve a Sound Transmission Class {STC) rating in walls of 50 decibles and an Impact Insulation Class (IIC) rating on floor/ ceiling of 50 decibles. Title 25 Show how penetration of assemblies for piping, electrical devices, recessed cabinets, bathtubs, soffits, or heating ventilating, or exhaust ducts shall be sealed, lined, or insulated to maintain required sound transmission rating. Title 25 Provide insulation in walls and ceiling to achieve STC of 50 between garage and living area if garage use is not controlled by resident Title 25. ENERGY CONSERVATION All additions to existing residential buildings must comply with Title 24 energy regulations. Additions exceeding 30% of the existing building requires the existing and addition to have R-19 ceiling insulation if the existing ceiling area is accessible for insulation installation (T20-140l(c). 272. Specify the insulation R valves for walls, roof and ceiling. (R-ll for walls: R-19 for ceilings, or provide details and analysis for alternate design. T20-1403 Table A & 2B. 273. specify the gross floor area or heated portions of the dwelling, and the area of glazed openings on the plan. (T20-1430) 274. Provide an an~lysis justifying increasing the single glazed area beyond 16\ of the gross floor area. Show method to reduce heat loss to that which would occur with basic glazing. (T20-l402,def.J 275. Provide energy analysis to show c~at the bonnet capacity of the gas central furnace does not exceed the building design heat loss by more than 301. (Exceptions: 48,000 BTU Hr. output furnace. See also California Efficiency Adjustment.) T24-l404 276. Note on plan that all tranverse ducts, plenums, and fitting joints of HVAC system shall be sealed with pressure sensitive tape or mastic to prevent air loss. T20-l404 277. Note on plan that insulation of ducts shall conform to UMC Section 100S. (T20-1404) 27B. Note on plan that all doors and windows to the exterior or to unconditioned areas shall be fully weather striped per ANSI Standard. (T20-1403l. 279. Note on plan that back draft dampers are required on all fan systems exhausting air from the building. T20-l403 280. Electrical resistance space heating shall not be used unless: a. 601 of heating/cooling is supplied by a nondeplet'able source. b. supplements a heat pump system. c. less i;han 101 of total heating system. d. life cycle cost analysis justifies. T20-1404 281. Note on plan that all heating and cooling equipment efficiencies shall conform to Title 20-Chapter 2, Subchapter 4, Article 4. (75% for forced air furnaces). 282. Note on plan that no natural gas, central heating plant may be installed without an Intermittent Ignition Device. T20-1405 283. Electric resistance water heating is not permitted unless verfied as cost effective by a life cycle cost analysis. T20-1406 NOTE: 284. Q..,_ 301. 302. 303. 304. 305. 306. 307. Outdoor pools with fossil fuel heaters require pool covers as well as other energy saving devices such as time clocks, etc. T20-1406 MISCELLANEOUS Show a minimum 2" air space and flashing between planter and building walls. Sec. 2S17(e) Specify material to be used under the shower tile. Sec. l707(al Specify lath and plaster to comply with Chapter 47, UBC. Two 3/4" copper pipes must be installed from water heater location to convenient location of future solar panels (City Ord.) Provide sleeves (roof jacks) in roof for two future 3/4" copper pipes to cunvenient location of future solar panels (City Ord.) Note that solar water piping is to be insulated in areas that are not heated or cooled. (City Ord.) See attachment for roofing requirements. The plans were reviewed based on the information shown on the plans. If the plans are in error, or changed during construction, the permittee shall contact the Building Department for review and prior approval before proceeding with the work: 0 Building plans are substantially correct and complete. By: ________________ _ Date: ________________ _ 0 Building plans would be substantially correct and complete if minor corrections are made at counter. By: _________________ _ Date: ________________ _ 0 Building plans require major corrections and complete plan recheck, by plan check engineer, is required. By: ________________ _ Date: ________________ _ If you have any questions regarding this plan check, please call ___________________ ,at _________ _ We would also be pleased to meet with you, at no charge, if additional assistance is needed. ► Date,#'2, Jurisdiction <Ja,,r,/4[)~ VALUATION AND PLAN CHECK FEE □ Bldg. Dept. l. '.:":-~ ,.1 t.-- Pr~y, PLAN CHECK NO. 92-/33 . c: ' BUILDING ADDRESS Z. st-4ta ..... :YT)/.-t', u I b ◊J 1 (. -r le' CL t::,~7 1 APPLICANT/CONTACT TQ G" lu t \ SOY) PHONE NO. '1"2.-°I '?.-4'~ 4- BUILDING OCCUPANCY \c.-3 1 V\/) DESIGNER PHONE _____ _ TYPE OF CONSTRUCTION V-fV CONTRACTOR PHONE ~0D1·11b1\) BUILDING PORTION BUILDING AREA VALUATION VALUE MULTIPLIER N Oo\2.. A-DO 11 6 ~1 ..,. '-+~ S-G, ' "2. A,) 1J '::)·+ti ) ~ '-1 \1~ 4-?-13':Jv \ ' ~ I 2 / - Air Conditionin£ Commercial -- Residential Fire S"Orinklers Total Value l '2-?::/J & I Building Fermi t Fee __ 1_8_, _9'_:::r-------- Plan Check Fee ~t,L-,C,fi --------'"--'---------- COMMENTS a _________________________ _ ,/ INTERDEPARTMENTAL INFORMATION SHEET DATE: 46'--~•<?'z-.. BUILDING DEPARTMENT BUILDING ADDRESS: W'2.L.-ta / 7 Z 30 {'{ PLANNING DEPARTMENT ZONE ____ ~_.__-_\ ____ LOT SIZE _________ LOT WIDTH ________ _ UN;TS ALLOWED \ UNITS PROVIDED --------------..J------------- PARKING SPACES REQUIRED r-_ PROVIDED ___________ _ % COVERAGE ALLOWED ~GC9 PROVIDED BUILDING HEIGHT ALL_O_W_E_D ___ 4 ,~,,~{;-+-+\------PROVIDED ====================== FRONT SETBACK: SIDE SETBACK: REAR SETBACK: ALLOWED l PROVIDED========\i=~~=C?"==== INTRUSIONS LANDSCAPE & IRRIGATION PLAN COMMENTS: ENVIRONMENTAL PROTECTION REQ: ADDITIONAL COMMENTS: OK TO ISSUE: .ATEfu OK TO FI NAL ________ DATE ____ _ ENGINEERING DEPARTMENT R.O.W. ______ INDUSTRIAL WASTE _______ IMPROVEMENTS _______ _ SEWER CONNECTION ________ DRIVEWAY LOCATIONS ____________ _ ______ EASEMENTS __________ DRAINAGE ____ _ I GRADING PERMIT LEGAL DESCRIPTION ------------------------------ ADDITIONAL COMMENTS ________ ....,.._ ___________________ _ OK TO rssu:~ATE 6)\7Yh, ____ oK TO FINAL. ____ DATE ___ _ FIRE DEPARTMENT SPRINKLING SYSTEM FIRE PROTECTION EQUIP. ______ _ FIRE ALARJl!S EXITS ________________ _ FIRE HYDRANTS ___________ LOCATION __________________ _ ADDITIONAL COMMENTS OK TO ISSUE: DATE OK TO FINAL DATE -----·----------------- WATER DEPARTMENT REQUIREMENTS OF APPROPRIATE DISTRICTS MET ________ DATE ________ _ I ----------------··--·----------------- May 5, 1982 Owners Clyde Ba rsdn 2440 Stromberg Circle Carlsbad, Ca. 92008 -~ Locations 2440 Stromberg Ci rel e Carlsbad, Ca. 92008 To whom it may concern: Property Development By Registered Civil Engineer JOHN £. VERNON 2860 Calmar Drive Escondido. Calif. 92025 (714) 745-8882 Thie ie to certify that I have made a fieict investigation of your foundation soil cond i ti one. I recommend a bt1arin;; value of 1500#/&.F. tu be used thrc~gho,t the planned foundation area. The existing footings can be used for support as long as the bearing pressure does not exceed the allowable. Thie value is b.']eed upon existing conditions with good ccnEt.ruction practices and with surface drainage adequately provided and maintained. away from the footings. ~~ John E. Vernon RCE 21121 Surveys -Tentative and Parcel Maps -Percolation Tests -Soil Tests and Reports Grading Plans -Improvement Plans -Engineering Calculations