Loading...
HomeMy WebLinkAbout2605 CARLSBAD BLVD; ; CBC2020-0449; PermitBuilding Permit Finaled Commercial Permit Print Date: 08/27/2021 Job Address: Permit Type: Parcel#: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Occupant Load: Code Edition: Sprinkled: Project Title: 2605 CARLSBAD BLVD, CARLSBAD, CA 92008-2208 BLDG-Commercia I Work Class: 2030410200 Track#: $58,555.00 Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check#: Description: ARMY AND NAVY ACADEMY: 500 SF BRIDGE REPLACEMENT Property Owner: Tenant Improvement ARMY AND NAVY ACADEMY CARLSBAD CALIFORNIA FEE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) PO BOX 3000 CARLSBAD, CA 92018 ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL FIRE R Occupancies All Tl's MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-COMMERCIAL Total Fees: $1,Sl0.38 Total Payments To Date: $1,510.38 (city of Carlsbad Permit No: CBC2020-0449 Status: Applied: Issued: Finaled Close Out: Inspector: Final Inspection: Balance Due: Closed -Finaled 11/10/2020 01/12/2021 TAlva 08/27/2021 AMOUNT $445.87 $312.11 $60.00 $628.00 $45.00 $3.00 $16.40 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov ('city of Carlsbad COMMERCIAL BUILDING PERMIT APPLICATION B-2 Plan Check Cfiff/ij;oL/<ff Est. Value Y" S:: ?- PC Deposit Date It-JD-Zo 2-U Job Address_-=26=.0=.5:....:C..::a;:.rl..::s:.ba=.d:....:B;:.lv...:d:.:.. ________ .Suite: ____ .APN: ___;2:.0;...3;_-.;_04_1-_0;_1 _____ _ Tenant Name: Army and Navy Academy Lot#: Year Built: _1_9_9...:20.-__ Occupancy: __ R_-1.:...._ __ Construction Type· V 1-H R Fire Sprinklers:[!! 9A/C:~ £!J BRIEF DESCRIPTION OF WORK: Demolish existing bridge. Reconstruct bridge in same location with similar building materials and new structural beams, columns, and foundations. Intercept and reconnect mechanical, electrical, plumbing, security/IT, fire alarm, and fire suppression systems. D Addition/New:, ___________ New SF and Use,, ___________ New SF and Use, ____ Deck SF, Patio Cover SF (not including flatwork) D Tenant lmprovement:. ______ SF, _____ SF, Existing Use ______ Proposed Use ______ _ Existing Use Proposed Use ______ _ D Pool/Spa:, _____ .SF Additional Gas or Electrical Features? ____________ _ DD DD DD D Solar: ___ KW, ___ ,Modules, ____ Mounted, Tilt: Yes/ No, RMA: Yes/ No, Panel Upgrade: Yes/ No D Plumbing/Mechanical/Electrical Only: --------------------------- Iii Other: Demolish existing bridge and reconstruct replacement bridge in same location. Total floor area of existing buildings is 19,236 SF. Total floor area of bridge is approximately 500 SF (including bridge and new foundation areas). This permit is to be issued in the name of the Property Owner as Owner-Builder, licensed contractor or Authorized Agent of the owner or contractor. The person listed as the Applicant below will be the main point of contact throughout the permit process. PROPERTY OWNER APPLICANT O PROPERTY OWNERS AUTHORIZED AGENT APPLICANT II] Name: Army and Navy Academy Name: _D=ou:;.gacl:::.as::...;..P.::a:..:te::.rs:.;o:::n...:A...:rc:c:::h:..:ite::.c:.:t ________ _ Address: 2605 Carlsbad Blvd. Address: _4.:.;6:.;5:.:3:..C=arc:.m:.::e:::l..::M:.::o:.:u::.n:.::ta:::i::.n.:.;R:..:d::. . ...:S:.;U:::it:::e:..:3:.:0:.:8:::i3::.:0:.:5:._ __ _ City: Carlsbad State: CA Zip: 92008 City: San Diego State: CA Zip: 92008 Phone: 760-547-5269 Phone: _.::.85:.;8:..-:::.20:.;0:..-:::.68:.;6:..4c_ ___________ _ Email: JPullen@armyandnavyacademy.org Email: __ d;;.w;:.rccp..::a:..:te::.r::.so;,;n:..:@=g;,;.m:.:accil...::c=.o:.:.m:._ ________ _ DESIGN PROFESSIONAL APPLICANT iJ CONTRACTOR BUSINESS APPLICANT 0 Name:_..;D;;,.o;;,.ucag,,;,la:::.s:....;...P.;;;at;,,;e.;,.rs...:o;,;.n...:A...:r...:c...:h;,;.ite;;..c;,,;t______ Name: Turner Construction Company Address: 4653 Carmel Mountain Rd. Suite 308/305 Address: 15378 Avenue of Science, Suite 100 City: San Diego State: CA Zip: 92008 City: San Diego State: CA Zip:_ 92128 Phone: 858-200-6864 Phone: 858-217-0700 Email: dwrpaterson@gmail.com Email: cjespersen@tcco.com Architect State license: _C_-2;.;8;.;8.;_7;;;.4 _______ State license: 210639 1635 Faraday Ave Carlsbad, CA 92008 B-2 Ph: 760-602-2719 Fax: 760-602-8558 Page 1 of 2 Bus. license: BLos1241aa1 Email: Building@carlsbadca.gov Rev. 08/20 IDENTIFY WHO WILL PERFORM THE WORK BY COMPLETING (OPTION A) OR (OPTION B) BELOW: (OPTION A): LICENSED CONTRACTOR !lECLARATION: I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. I also affirm under penalty of perjury one of the following declarations: 0 I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit Is iss1.1ed, Polley No. ll I have and will maintain worbr's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit Is 1ssL.1ed. My workers' compen,-atlon Insurance carrier and pollcy number are: Insurance Company Name: 1JhArlV MllhJal CocporaUon Palley No. #WC5-625-092815-030 Expiration Date: ____,1..11J.J/0_._1.uL,a?i.,_Q_,.5'...J!_,__ _________ _ 0 Certificate of ElCemptlon: 1 certify that in the performance of the work for which this permit is issued, I srlall not employ any person in anv manner so as to become subject to the worker.,;' compensation laws of Callfomla. WARNING: Falh.1re to secure workers compenHtlon coverage is unlawful and shall subject an emplover to criminal penaltles and clvll fines up to $100,000.0D, In addition tl\e to the cost of compenHtlon, damages es provided for In Section 370& of the Labor Code, Interest and attorney's fees. CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending as ency for the performance of the work this permit is i,;:sued (Sec. 3097 (I) Civil Code), L<nde~,Name, Lende~•Ad~ CONTRACTORPRINT:C/,~r,_1u~,.J<'__, SIGN: ~ DATE: (OPTION B): OWNER-BUILDER DECLARATION: I hereby affirm that I am e,cempt from Conrraaor's License Law for the fallowing reason: Qi, as:owner of the property or my employees with wages as their sole compensation, will do the work and the structure i~ not Intended or offered for sale (Sac. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and who does such work himself or through his own eJTiployees, provided that such Improvements are not Intended or offered for sale. If, howeYer, the btJildlng or improvement Is sold within one year of completion, the owner·builderwill have the burden of proving that he did not build or Improve for the purpose of sale), Q1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's UcenH Law does not apply to an owner of property who builds or Improves thereon, and contracts for such projects With contractor(s) llcensed pursuant to the Contractor's License Law). 0 I am e11empt under Business and Professions Code OlvisM>n 3, Chapter 9, Artlcle 3 for this reason: 0 "Owner Duildar acknowledsement and verification form" has been filled out, signed and attached to thls applicatlon. Ptoof of Identification attached. 0 owners "Authorized Agent Form" has been filled out, signed and attached to this appllcation giving the agent authority ta obtain the ~rmlt on the owner' behalf. Proof of identlfication attached. By my signature below I acknowledge ttiat, except for my personal residence In which I must have resided for at least one year prior to completion of the lmpnwements cO\leted by this permit, I cannot legally sell a structure that I have built as an owner-builder if It has not been constructed In Its entirety by llcensed contractors. I understand that a copy of the oppllc:abk low, Section 7044 of the BtJSiness and Pro/e$Sfons Code, Is ava//ab!e upon request whrn this ap(Jllcation Is $Ubmitted or at tM following Website~ http://www.leglnfo.ca.gov/calaw.html OWNER PRINT: ___________ Sl~.N: ________ ,DATE: _____ _ APPLICANT CERTIFICATION: SIGNATURE REQUIRED AT THE TIME OF SUBMITTAL By my signature below, I certify that: I am the property owner or State of CaHJornia Ucensed Controet_or _or outh_orlzed to act on the property owner or contractors behalf, I certify that I have read the appllcatlon and state that the above information is COffed and that the fnformatlon on the plans iS accurate. I agree to comply with 011 Clt'y ordlriOlices and State laws relating to·building--eonstructlon. -----------I-hereby-authorize.representative of theJ;it_y.Ef_Carlsbad to enter upon the above mentioned property for inspection purposes. I Al.SO AGREE TO SAVE; INDEMNIFY AND KEEP HARMLESS mE QTY DF CAil!SBAD AGAINST All llAIJll./11£5,JOU<iMEN'l"S,~---flEXPENSES WHIOJMAYJNANr~WM ACCRUE AGAINST SAID QTY IN CONSEQUENCE Of THE GRANTING OF THl5 PERMIT. OSHA: An 05HA permit is required for excavatlons over 5'0' ----·---- deep and demolition or construction of structures over 3 stories in height. APPLICANT PRINT: Douglas W. Paterson SIGN: -~-~-~_v--___ -__ DATE: _11_1o_s_12_02_0 __ 1635 Faraday Ave carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov Rev. 08/20 B-2 Page 2 012 Permit Type: BLDG-Commercial Work Class: Tenant Improvement Status: Scheduled Date Closed -Finaled Actual Inspection Type Start Date Checklist Item BLDG-Plumbing Final BLDG-Structural Final BLDG-Electrical Final Friday, August 27, 2021 Application Date: 11/10/2020 Owner: ARMY AND NAVY ACADEMY CARLSBP CALIFORNIA Issue Date: 01/12/2021 Expiration Date: 09/01/2021 IVR Number: 29878 Subdivision: GRANVILLE PK #2 Address: 2605 CARLSBAD BLVD CARLSBAD, CA 92008-2208 Inspection No. Inspection Status Primary Inspector Reinspection Inspection COMMENTS August 27, 2021: 1. Final building inspection no deficiencies on new bridge between school buildings-approve. 2. Electrical, plumbing drains, and structural reinforcement, per structural engineered plans and detail specifications-approved. August 27, 2021: 1. Final building inspection no deficiencies on new bridge between school buildings-approve. 2. Electrical, plumbing drains, and structural reinforcement, per structural engineered plans and detail specifications-approved. August 27, 2021: 1. Final building inspection no deficiencies on new bridge between school buildings-approve. 2. Electrical. plumbing drains, and structural reinforcement, per structural engineered plans and detail specifications-approved. Passed Yes Yes Yes Page 4 of 4 Permit Type: BLDG-Commercial Work Class: Tenant Improvement Status; Scheduled Date Closed -Finaled Actual Inspection Type Start Date Checklist Item Application Date: 11/10/2020 Owner: ARMY AND NAVY ACADEMY CARLSBP Issue Date: 01/12/2021 Expiration Date: 09/01/2021 IVR Number: 29878 Inspection No. COMMENTS Inspection Status CALIFORNIA Subdivision: GRANVILLE PK #2 Address: 2605 CARLSBAD BLVD CARLSBAD, CA 92008-2208 Primary Inspector Reinspection Inspection Passed BLDG-Building Deficiency February 18, 2021: (Virtual inspection). (No building deficiencies). Yes 03/05/2021 05/13/2021 08/27/2021 03/05/2021 BLDG-18 Exterior Lath/Drywall Checklist Item 1 . New structurally self-supporting engineered bridge between buildings. 2. New wood walking deck moisture resistant material installed, metal flashing, and rough electrical conduit at all wood frame (6) pilasters, scope of work per engineer plans -approved. 152139-2021 Passed Tony Alvarado COMMENTS BLDG-Building Deficiency March 5, 2021 (Virtual Inspection) No Building Deficiencies. 05/13/2021 BLDG-Final Inspection Checklist Item 1. Building patch work sections to match existing, located at bridge and adjacent buildings at each side of repaired/modified pedestrian bridge between two classroom buildings. 2. Exterior stucco Approved metal lath paper and nailing pattern with metal corner beads installed correctly, scope of work-approved. 157409-2021 COMMENTS Failed Tony Alvarado BLDG-Building Deficiency May 13, 2021: BLDG-Structural Final 08/27/2021 BLDG-Final Inspection 1. Final building inspection deficiencies on new bridge between school buildings. (Not ready). 2. Contractor rep. John-superintendent - will reschedule for Final Inspection. May 13, 2021: 1. Final building inspection deficiencies on new bridge between school buildings. (Not ready). 2. Contractor rep. John-superintendent - will reschedule for Final Inspection. 165281-2021 Passed Tony Alvarado Friday, August 27, 2021 Complete Passed Yes Reinspection Incomplete Passed No No Complete Page 3 of 4 Permit Type: Work Class: Status: Scheduled Date 02/18/2021 BLDG-Commercial Application Date: 11/10/2020 Owner: ARMY AND NAVY ACADEMY CARLSBP CALIFORNIA Tenant Improvement Issue Date: 01/12/2021 Subdivision: GRANVILLE PK #2 Closed -Finaled Expiration Date: 09/01/2021 Address: 2605 CARLSBAD BLVD IVR Number: 29878 CARLSBAD, CA 92008-2208 Actual Inspection Type Inspection No. Inspection Primary Inspector Start Date Status Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency COMMENTS February 2, 2021: "No building deficiencies". 1. Crean Hall and Atkinson Hall Buildings-wood 2x framing at each end of bridge columns, connection points/method of attachment at each ends of pedestrian walking bridge connecting both buildings-approved per plan. February 16, 2021: 1. New detached independent bridge, between Crean-Hall and Atkinson Hall buildings, constructed per structural engineer plans, scope of rough framing work-approved. 2. Wood bridge floor sheathing wood type and wood nailing pattern, scope of work-approved. 3. Metal flashing at top of wood horizontal/vertical surfaces at walking bridge-approved. 4. Existing utility and fire sprinkler system plumbing lines, water drain lines, not modified/altered or repaired. 5. Plywood shear wall wood-type and wood-nailing pattern, scope of work-approved. 02/18/2021 BLDG-14 150777-2021 Passed Tony Alvarado Frame/Steel/Bolting/We ldlng (Decks) Checklist Item BLDG-Building Deficiency COMMENTS February 18, 2021: (Virtual inspection). (No building deficiencies). 1. New structurally self-supporting engineered bridge between buildings. 2. New wood walking deck moisture resistant material installed, metal flashing, and rough electrical conduit at all wood frame (6) pilasters, scope of work per engineer plans -approved. BLDG-34 Rough Electrical 150776-2021 Passed Tony Alvarado Reinspection Passed Yes Yes Passed Yes Inspection Complete Complete Friday, August 27, 2021 Page 2 of 4 Building Permit Inspection History Finaled (city of Carlsbad Permit Type: BLDG-Commercial Work Class: Tenant Improvement Status: Closed -Finaled Scheduled Actual Inspection Type Date Start Date 01/25/2021 01/24/2021 BLDG·11 Foundatlon/Ftg/Plers (Rebar) Checklist Item Application Date: 11/10/2020 Owner: ARMY AND NAVY ACADEMY CARLSBP CALIFORNIA Issue Date: 01/12/2021 Subdivision: GRANVILLE PK #2 Expiration Date: 09/01/2021 IVR Number: 29878 Address: 2605 CARLSBAD BLVD CARLSBAD, CA 92008-2208 Inspection No. Inspection Primary Inspector Reinspection Inspection Status 148881 •2021 Passed Tony Alvarado Complete COMMENTS Passed BLDG-Building Deficiency January 22, 2020: Yes 02/02/2021 02/02/2021 BLDG•14 Frame/Steel/Boltlngtwe ldlng (Decks) Chccklis1 Item 1. (4) isolated spread footings for remodeled/repaired bridge-walkway, footings with reinforcement steel rebar, per engineers plans detailed specifications-approved. 2. Deputy inspector report verified. 3. Ok to pour concrete. 149588-2021 Partial Pass Tony Alvarado COMMENTS BLDG-Building Deficiency February 2, 2021: 02/16/2021 02/16/2021 BLDG•14 Frame/Steel/Bolting/We ldlng (Decks) Friday, August 27, 2021 ·········~---- "No building deficiencies". 1. Crean Hall and Atkinson Halt Buildings-wood 2x framing at each end of bridge columns, connection points/method of attachment at each ends of pedestrian walking bridge connecting both buildings-approved per plan. 150613•2021 Passed Tony Alvarado Reinspection Incomplete Passed Yes Complete Page 1 of 4 (>City of Carlsbad OWNERS AUTHORIZED AGENT FORM B-62 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov OWNER'SAUTHORIZED AGENT FORM Only a property owner, contractor or their authorized agent may submit plans and applications for building permits. To authorize a third-party agent to sign for a building permit, the owner's third party agent must bring this signed form, which identifies the agent and the owner who s/he is representing, and for what jobs s/he may obtain permits. The form must be completed in its entirety to be accepted by the City for each separate permit application. Note: The following Owner's Authorized Agent form is required to be completed by the property owner only when designating an agent to apply for a construction permit on his/her behalf. AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Property Owner Acknowledgement, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner-Builder Permit for my project. Demolish existing bridge. Reconstruct bridge in same location with similar building materials and new structural beams, columns, and scope of construction Project jar Description of Work): foundations. Intercept and reconnect MEP and Fire-Life Safety systems. Project Location or Address: 2605 Carlsbad Blvd., Carlsbad. CA 92008 Name of Authorized Agent: Douglas Paterson Architect Tel No. 858-200-6864 Address of Authorized Agent: 4653 Carmel Mountain Road. San Diego, CA 92130 I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. -1:?Jf/rJ3:o"'"<---~ 11/06/2020 Property Owner's Signature: _____________________ Date: _______ _ 1 DATE: 12/02/2020 JURISDICTION: CARLSBAD PLAN CHECK#.: CBC2020-0449 ✓• EsG1I A SMF built'Compiltl'.I' SET: I PROJECT ADDRESS: 2605 CARLSBAD BOULEVARD PROJECT NAME: BRIDGE FOR ARMY AND NAVY ACADEMY ~PPL I CANT ! aURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. cg] The plans transmitted herewith will substantially comply with the jurisdiction's BUILDING codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: cg] EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: Jz.jz.120 (by'z>fy'l) Email: Mail Telephone Fax In Person cg] REMARKS: Please have the Electrical and the Mechanical engineers ~ch sheet of the plan~ rS.JV --, "' By: Bert Domingo Enclosures: EsGil 11/13/2020 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 CARLSBAD CBC2020-0449 12/02/2020 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: CARLSBAD PREPARED BY: Bert Domingo PLAN CHECK#.: CBC2020-0449 DATE: 12/02/2020 BUILDING ADDRESS: 2605 CARLSBAD BOULEVARD BUILDING OCCUPANCY: BRIDGE BUILDING AREA Valuation PORTION (Sq.Ft.) Multiplier CITY ESTIMATE Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code CB By Ordinance -------------------------, 1997 U B ildin Permit Fee BC u g .,,, ' -- 1997 UBC Plan Check Fee Type of Review: 0 Complete Review D Repetitive Fee ----.,,,---, Repeats I □ Other D Hourly EsGil Fee Reg. VALUE Mod. D Structural Only ~-----11Hr. @ * Comments: In addition to the above fee, an additional fee of$ $ /hr.) for the CalGreen review. ($) 58,555 58,555 ~---$2_8_6_.6~31 ~ is due ( hour@ Sheet 1 of 1 ' Qualls Engineering Structural Engineering Services GOVERNING CODE: CONCRETE: REINFORCING STEEL: STRUCTURAL STEEL: SAWN LUMBER: ENGINEERED WOOD Project Army Navy Bridge Engineer: Jacob Farabaugh DESIGN BASIS 2019CBC r, = 2,S00 psi (MINIMUM) ASTM A61S, F,. = 60 ksi ASTM A992, Fr= SO ksi (''W' SHAPES ONLY) Sheet: 1/20 ---'-'--- Job#: 20199 Date: 10/16/20 ASTM i\36, F,-= 36 ksi (STRUCTURAL PL-I.TES, ANGLES, CHANNELS) ASTM AS00, GR C, Fr= SO ksi (STRUCTURAL RECT & SQ HSS TUBES) DOUGLAS FIR LARCH, ALLOW.'\.BLE STRESS DESIGN PER 2019 CBC. BOISE C.\SCADE OR EQUIVALENT BC! WOOD "I' JOISTS -ICC-ESR 1336 BC VERSAL\M 2.0E/LVL/LSL-ICC-ESR 1040 PROJECT SCOPE Project consists of a proposed new bridge to span between 2 existing two-story dormitory buildings located at the Army and Navy Academy, Carlsbad, CA 92006 The proposed bridge is primarily constructed utilizing wood frame construction with steel columns for lateral support. The foundation will be spread footings placed to avoid undermining existing footings, and the bridge will be seismically isolated. There has not been a soils report provided for this project. Therefore, the foundation design will be based on minimum soils values per 2019 CBC chapter 18. .. Qualls Engineering Structural Engineering Services Design Loads: Bridge Deck: Dead Load ( DL) Dcx-O-Tcx 3/4" Plywood rraminR Sntcco Misc. I:DL= LL= Walls: Dead Load ( DL ): Exterior Srud Walls Interior Stud Walls Allowable Soils Bearing Prcssu.re: :\SBP = Seismic: 2.5 2.3 2.9 10.0 2.3 200 100.0 15 U -o 1.500 Site Class: D S,=1096 S1 = 0.396 Occupancy C3cegory II Wind Load: (Simplified Envelope Procedure) Project: ,tl IV) ( -N 4 vY Sheet: 2 ..;;... ___ _ Job#: ]..oJqq Engineer: ______ J_f _______ _ Date: ----- psf psf psf psf csf psf psf psf psf psf@ 18 inches below lowest adjacent finished p;ratk F, = 1.200 F_. = - Response Importance Motl. Factor Factor. I R I 00 2.5 s~t, = 1.31:; S~II: Redundancy pCs Factor SDs/(R/1) p I I .HJ-I) 1 I 3 0.456 S05 = 0.877 Soi= - \:,,1) 0.326 Basic \Vind Speed: 95 mph Exposure: <: MWFRS P = 0.6•>.•K,t P,:io >. = 1.21 (LRr:D): I' = 16.0 psf K:i, = 1.0 (ASD): p =1 9.6 lrsf P~:io= 13.2 C2m1ums::u,1 ~ Cladwo& P = 0.6•>.•K.,•P,30 Pn«JO= 16.2 (I.RFD): I'= 19.6 psf (ASD): P =I 11.8 !rsf Qualls Engineering Project Title: Army Navy Bridge Engineer: Jacob Farabaugh 4403 Manchester Ave, Suite 203 Encinitas, CA 92024 t: (760) 652-9257 Wood Beam ,., •... DESCRIPTION: FB-1 CODE REFERENCES Calculations per NOS 2012, IBC 2012, CBC 2013, ASCE 7-10 Load Combination Set : ASCE 7-16 Material Pro erties Project ID: 20199 ProJect Descr: Analysis Method : Allowable Stress Design Load CombinaUonASCE 7-16 Fb t Fb- 2,400.0 psi 2,400.0 psi 1,650.0 psi E : Modulus of Elasticity Wood Species : OF/OF Wood Grade : 24F -V8 Fc -Prll Fe -Perp Fv Ft Beam Bracing : Beam is Fully Braced against lateral-torsional buckling 0/0. 10501 L/0.80\ 6.7. 6.75x27 Span = O 750 fl Span = 30.50 ft 650.0 psi 265.0 psi 1,100.0 psi Ebend-xx 1,800.0 ksi Eminbend -xx 950.0 ksi Ebend-yy 1,600.0ksi Eminbend -yy 850. 0 ksi Density 31.210pcf ( ' tM.,.75x27 S an = 2.50 ft A lied Loads Service loads entered. Load Factors will be applied for calculat,or Beam self weight calculated and added to loads Loads on all spans ... Uniform Load on ALL spans : D = 0.1050, L = 0.80 k/ft DESIGN SUMMARY Maximum Bending Stress Ratio = 0.77l 1 Maximum Shear Stress Ratio Section used for this span 6.75x27 Section used for this span = 1,603.30psi = 2,074.0?psi Load Combination tD+L+H, LL Comb Run (•L•] Load Combination Location of maximum on span = 15.122ft Location of maximum on span Span # where maximum occurs = Span# 2 Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection 0.792 in Ratio= 462 >=240 Max Upward Transient Deflection -0.062 in Ratio= 292 >=240 Max Downward Total Deflection 0.933 in Ratio= 392 >=240 Max Upward Total Deflection -0.072 in Ratio= 248 >=240 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values Segment Length Span# M V Cd C FN C1 Cr Cm Ct CL M fb +041 Length = 0. 750 ft 1 0.000 0.065 0.90 1,000 1.00 1.00 1.00 1.00 1.00 0.04 0.59 Length = 30.50 ft 2 0.130 0.066 0.90 0.864 1.00 1.00 1.00 1.00 1.00 16.56 242.26 Length = 2.50 ft 3 0.003 0.066 0.90 1.000 1.00 1.00 1.00 1.00 1.00 0.45 6.61 +0-+l-♦+i, LL Comb Run ("I.) 1.000 1.00 1.00 1.00 1.00 1.00 Length = 0.750 ft 1 0.000 0.056 1.00 1.000 1.00 1.00 1.00 1.00 1.00 0.04 0.59 Length = 30.50 ft 2 0.108 0.062 1.00 0.864 1.00 1.00 1.00 1.00 1.00 15.34 224.43 Length = 2.50 ft 3 0.018 0.062 1.00 1.000 1.00 1.00 1.00 1.00 1.00 2.95 43.19 +0-+l-♦+i, LL Comb Run (*L ') 1.000 1.00 1.00 1.00 1.00 1.00 Length= 0.750 ft 1 0.000 0.387 1.00 1.000 1.00 1.00 1.00 1.00 1.00 0.04 0.59 Length = 30.50 ft 2 0.773 0.388 1.00 0.864 1.00 1.00 1.00 1.00 1.00 109.58 1,603.30 Length = 2.50 ft 3 0.003 0.388 1.00 1.000 1.00 1.00 1.00 1.00 1.00 0.45 6.61 Desi n OK = 0.390 : 1 6.75x27 = 103.39 psi = 265.00 psi +D+L +H, LL Comb Run (•LL; = 28.450ft = Span# 2 Shear Values F'b V fv F'v 0.00 0,00 0.00 0.00 2160.00 1.89 15.59 238.50 1866.67 1.92 15.81 238.50 2160.00 0.04 15.81 238.50 0.00 0.00 0.00 0.00 2400.00 1.81 14.91 265.00 2074.07 2.00 16.48 265.00 2400.00 0.24 16.48 265.00 0.00 0.00 0.00 0.00 2400.00 12.45 102.50 265.00 2074.07 12.48 102.72 265.00 2400.00 0.04 102.72 265.00 Qualls Engineering 4403 Manchester Ave, Suite 203 Encinitas, CA 92024 t: (760) 652-9257 Wood Beam .. ,,. DESCRIPTION: FB-1 Load Combination Max Stress- Segment Length Span# M V +O+L~. LL Comb Run ("LL) Length= 0.750 ft 1 0.000 0.384 Length = 30.50 ft 2 0.784 0.390 Length = 2.50 ft 3 0.018 0.390 +O+L~. LL Comb Run (L ") Length = 0. 750 ft 1 0.002 0.059 Length = 30.50 ft 2 0.118 0.059 Length = 2.50 ft 3 0.003 0.059 +O+L~. LL Comb Run (L i.i Length= 0.750 ft 1 0.002 0.057 Length = 30.50 ft 2 0.107 0.082 Length = 2 .50 ft 3 0.018 0.082 +O+L ~. LL Comb Run (LL 1 Length= 0.750 ft 1 0.002 0.387 Length • 30.50 ft 2 0.772 0.387 Length = 2.50 ft 3 0.003 0.387 +O+L ~. LL Comb Run (LLL) Length= 0.750 ft 1 0.002 0.384 Length= 30.50 ft 2 0.763 0.390 Length = 2.50 ft 3 0.018 0.390 Overall Maximum Deflections Load Combination Span 1 +O+L ~. LL Comb Run ("I. 'I 2 3 Vertical Reactions Load Combination overall MAximum Overall MINinum +O~ +O+L~. LL Comb Run (""I.) +O+L ~. LL Comb Run ('L ') +O+L~. LL Comb Run ("LL) +O+L~. LL Comb Run (L ") +O+L~. LL Comb Run (Li.) +O+L ~. LL Comb Run (LL') +O+L~. LL Comb Run (LLL) D Only L Only, LL Comb Run ("L) L Only, LL Comb Run ("I.") L Only, LL Comb Run ("LL) L Only, LL Comb Run (L -1 L Only, LL Comb Run (L "I.) L Only, LL Comb Run (LL") L Only, LL Comb Run (LLL) Cd CFN C; c, Cm 1.000 1.00 1.00 1.00 1.00 1.000 1.00 1.00 1.00 1.00 0.884 1.00 1.00 1.00 1.00 1.000 1.00 1.00 1.00 1.000 1.00 1.00 1.00 1.00 1.000 1.00 1.00 1.00 1.00 0.884 1.00 1.00 1.00 1.00 1.000 1.00 1.00 1.00 1.000 1.00 1.00 1.00 1.00 1.000 1.00 1.00 1.00 1.00 0.884 1.00 1.00 1.00 1.00 1.000 1.00 1.00 1.00 1.000 1.00 1.00 1.00 1.00 1.000 1.00 1.00 1.00 1.00 0.884 1.00 1.00 1.00 1.00 1.000 1.00 1.00 1.00 1.000 1.00 1.00 1.00 1.00 1.000 1.00 1.00 1.00 1.00 0.884 1.00 1.00 1.00 1.00 1.000 1.00 1.00 1.00 Max.'.' Dell Locetlon In Span 0.0000 0.000 0.9328 15.378 0.0000 15.378 Project Tttle: Army Navy Bridll,e Engineer: Jacob F arabaug Project ID: 20199 ProJect Descr: Printed 16 OCT 2020, 12 02PM : rmy avy -ht ENERCALC, INC. 19113-2020, Bulld:12.20.3.25 Momen1 Values C I CL M fb 1.00 1.00 1.00 1.00 0.04 0.59 1.00 1.00 108.34 1,585.18 1.00 1.00 2.95 43.19 1.00 1.00 1.00 1.00 0.27 3.89 1.00 1.00 16.44 240.60 1.00 1.00 0.45 8.61 1.00 1.00 1.00 1.00 0.27 3.89 1.00 1.00 15.22 222.71 1.00 1.00 2.95 43.19 1.00 1.00 1.00 1.00 0.27 3.89 1.00 1.00 109.46 1,601.64 1.00 1.00 0.45 8.61 1.00 1.00 1.00 1.00 0.27 3.89 1.00 1.00 108.22 1,583.50 1.00 1.00 2.95 43.19 Load Combination +O+L ~. LL Comb Run ("I.") +O+L ~. LL Comb Run (i. 1 • F'b V 0.00 0.00 2400.00 12.37 2074.07 12.56 2400.00 0.24 0.00 0.00 2400.00 1.90 2074.07 1 .91 2400.00 0.04 0.00 0.00 2400.00 1.82 2074.07 2.00 2400.00 0.24 0.00 0.00 2400.00 12.48 2074.07 12.47 2400.00 0.04 0.00 0.00 2400.00 12.38 2074.07 12.58 2400.00 0.24 Max. "+" Defl -0.0724 0.0000 -0.2409 Shear Values fy F'v 0.00 0.00 101.82 265.00 103.39 265.00 103.39 265.00 0.00 0.00 15.85 265.00 15.75 265.00 15.75 265.00 0.00 0.00 14.97 265.00 16.42 265.00 16.42 265.00 0.00 0.00 102.56 265.00 102.66 265.00 102.66 265.00 0.00 0.00 101.66 265.00 103.33 265.00 103.33 265.00 Location In Span 0.000 0.000 2.500 Support notation : Far left is #1 Values in KIPS Support 1 Support 2 Support 3 Support4 15.106 16.860 12.725 14.275 2.299 2.578 2.217 4.860 14.499 14.778 14.417 18.860 2.906 2.571 2.824 4.653 15.106 14.771 15.024 16.853 2.299 2.578 -0.082 2.082 12.200 12.200 12.118 14.282 0.607 -0.007 0.525 2.075 12.607 12.193 12.725 14.275 Qualls Engineering Structul'al Engineering Services Project: Al1'1Y • N ,4 vY Sheet: s --- Job #: 'l.. DI '1q Date: Engineer: J ~ __ _;_; ___ _ ? (~ ::: 0, L\ ?ti ( L -,< ;;o) $To(Y lfEICIIT ~ /0, f--~1 -$ CJ-;.'l.•> f>~f 7fftA-l' q1,c;x ,Y~ ----~ B;45f c;11-fA{l .:: L-f/ i:;6 Ji Dt.4PH(l"GN1: ~,<?,tj t-tupsf =-54 1,\0 i- ,_,..,,,4-\15, ' /Ox '~nXI> t 7o)(.1.s~ ~-:.. ~ b7S fl T01Al le,~(>-: q IIS tf .J ~-: 075 h ., 6,q::.. (_.o-ZS )( IO)(fz) : 3 (~ A ,, ~ /~ \ 1_'' 1S ,,. \ 1-$ ~EJ~Mil >E?E t 4hoN' · . 1,<trOtE ', ~MT -Jc~I'?, )11J~i)1 ~.: 6 C.t-i - : (. eg )(7 S) (,../I,:. (c. i 11.:, (~1')1 ~M,:: 1_,?_ I/ ~M'f-::,. tt , s 1 ' f',/N) 0Cj£: y.i"Z,, 'I S:-.,1 :. s1~ r' Oi?r ;:r ~1 ~ C:.q ::. (.()I)( /0)(1Z) f;,,_ t C \ 'l, ,, J STof:'t-' O'f..irt or: /¥14x.wf!J/ ,8vJc JX:l,-1,,,'6 Qualls Engineering 4403 Manchester Ave, Suite 203 Encinitas, CA 92024 t: (760) 652-9257 Steel Column ,., •... DESCRIPTION: Stl Col Sketches C: 0 0 ~ +Y Load 1 - 4.00in +X Project Title: Army Navy Bridge Engineer: Jacob Farabaugh Project ID: 20199 ProJect Descr: Software 0 . t ..... ..... r I. Qualls Engineering 4403 Manchester Ave, Suite 203 Encinitas, CA 92024 t (760) 652-9257 Steel Column ,., ... ' DESCRIPTION: SU Col Code References Calculations per AISC 360-10, IBC 2012, CBC 2013, ASCE 7-10 Load Combinations Used : ASCE 7-16 General Information Steel Section Name : Analysis Method : HSS4x4x1/2 Allowable Strength Project Title: Army Navy Bridge Engineer: Jacob Farabaugh Protect ID: 20199 ProJect Descr: 7 Printed 16 OCT 2020. 12.02PM y wvy e. Software copy ht ENERCALC, INC. 1983-2020, Bulld:12.20.3.25 .. Overall Column Height 9.0 ft Top & Bottom Fixity Top Free, Bottom Fixed Steel Stress Grade Fy : Steel Yield . A500, Grade C, Fy = 50 ksi, Carbon 50.0 ksi Brace condition for deflection (buckling) along columns : X-X (width) axis : E : Elastic Bending Modulus 29,000.0 ksi Unbraced Length for buckling ABOUT Y • Y Axis = 9 ft, K = 2 1 Y-Y (depth) axis : Unbraced Length for buckling ABOUT X-X Axis = 9 ft, K = 2.1 A lied Loads Column self weight included : 193.485 lbs • Dead Load Factor AXIAL LOADS ... Axial Load at 9.0 ft, D = 2.50, L = 14.30 k BENDING LOADS ... Lat. Point Load at 9.0 ft creating Mx-x, E = 1.039 k DESIGN SUMMARY Bending & Shear Check Results PASS Max. Axial+Bending Stress Ratio = 0.6108 : 1 Load Combination +D+O. 750L +O. 750S+0.5250E+H Location of max.above base O. 0 ft At maximum location values are ... Pa : Axial Pn I Omega : Allowable MH: Applied Mn-x / Omega : Allowable Ma-y : Applied Mn-y I Omega : Allowable PASS Maximum Shear Stress Ratio= Load Combination Location of mS,t.above base At maximum locatlon values are ... Va: Applied Vn / Omega : Allowable Load Combination Results 13.418 k 34.973 k -4.909 k-ft 19.212 k-ft 0.0 k-ft 19 212 k-ft 0.01671 : 1 +D+0.70E+0.60H 0.0 ft 0.7273 k 43.521 k Maximum Axial + Bending Stress Ri!tios Cbx Load Combination Stress Ratio Status Location +D+H 0.077 PASS 0.00 ft 1.67 +D+L+H 0.486 PASS 0.00 ft 1.67 +D+0.70E+0.60H 0.379 PASS 0.00 ft 1.67 +D+0.750L +0.750S+0.5250E+H 0.611 PASS 0.00 ft 1.67 +0.60D+0.70E+H 0.364 PASS 0.00 ft 1.67 Maximum Reactions Service loads entered. Load Factors will be applied for calculatior Maximum Load Ruction• .. Top along X-X Bottom along X-X Top along Y-Y Bottom along Y-Y Maximum Load 0.fttcilona ... 0.0 k 0.0 k 0.0 k 1.039 k Along Y-Y 0.8805 In at 9.0ft above base for load combination :+D+O. 70E+0.60H Along X-X 0.0 in at 0.0ft above base for load combination : M~imum Shei!r RatiQs Cby Kxlx/Rx KyLy/Ry Stress Ratio Status Location 1.00 160.85 160.85 0.000 PASS 0.00 ft 1.00 160.85 160.85 0.000 PASS 0.00 ft 1.00 160.85 160.85 0.017 PASS 0.00 ft 1.00 160.85 160.85 0.013 PASS 0.00 ft 1.00 160.85 160.85 0.017 PASS 0.00 ft Note. Only non-zero reactions are hste< Axial Reactlon @Base X-X Axis Reaction k Y-Y Axis Reaction Mx • End Moments k-ft My • End Moments Load Combination -+O~ -+{),+{.~ -+0-+0.70E-+0.60H -+0-+0. 7 50L-+O. 750S-+0.5250E -+I -+0.600-+0.70E-+-t D Only Lr Only 2.693 16.993 2.693 13,418 1.616 2.693 @ Base @ Top @ Base @ Top 0.727 0.545 0.727 @Base @Top @Base @Top -6.546 -4.909 -6.546 Qualls Engineering 4403 Manchester Ave, Suite 203 Encinitas, CA 92024 t: (760) 652-9257 DESCRIPTION: SIi Col Maximum Reactions Load Combination L Only E Only Extreme Reactions Axial Reaction @Base 14.300 Axial Reaction Item Extreme Value @ Base Axlal@ Base Reaction, X-X Axis Base Reaction, Y-Y Axis Base Reacllon, X-X Axis Top Reactlon, Y-Y Axis Top Moment, X-X Axis Base Moment Y-Y Axis Base Moment X-X Axis Top Moment Y-Y Axis Top Maximum Minimum Maximum Minimum Maximum Minimum Maximum Minimum Maximum Minimum Maximum Minimum Maximum Minimum Maximum Minimum Maximum Minimum 16,993 2.693 2.693 2.693 2.693 2.693 2.693 2.693 2.693 2.693 2.693 2.693 2,693 2.693 2.693 Maximum Deflections for Load Combinations Load CombinaUon Max. X-X Deflection ..0-++i 0,0000 in ..O+l-++i 0.0000 In ..0+0.70E.0.60H 0.0000 in ..0+0.750L .0.750S+0.5250E-++i 0.0000 In +0.60D+0.70E4i 0.0000 in D Only 0.0000 in Lr Only 0.0000 in L Only 0,0000 In Steel Section Properties HSS4x4x1/2 Depth 4.000 In I xx Design Thick = 0.465 In s xx Width 4.000 In Rxx Wall Thick 0.500 In zx Area = 6.020 in•2 I yy Weight = 21 498 pit s yy Ryy Ycg = 0.000 in Project Title: Anny Navy Bridge Engineer: Jacob Farabaugh Project ID: 20199 ProJect Descr: Printed 16 OCT 2020, 12.02PM : rmy avy e. Software copyright ENERCALC, INC. 1983-2020, Bulld:12.20.3.25 . ' Note: Only non-zero reactions are lisle< X-X Axis Reaction k Y-Y Axis Reacllon Mx -End Moments k•ft My • End Moments @Base @Top @Base @Top @Base @Top @Base @Top 1.039 -9.351 X·X Axis Reaction k Y-Y Axis Reacllon Mx -End Moments k·ft My -End Moments @Base @Top @Base @Top @Base @Top @Base @Top 1.039 -9.351 -9.351 1.039 -9.351 Distance Max. Y-Y Deflection Distance 0.000 ft 0,000 In 0.000 ft 0,000 ft 0.000 in 0.000 ft 0.000 ft 0.880 in 9,000 ft 0,000 ft 0.660 in 9.000 ft 0.000 ft 0.880 In 9.000 ft 0,000 ft 0.000 In 0,000 ft 0.000 ft 0.000 In 0.000 ft 0.000 ft 0.000 in 0,000 ft = 11 90 ln'4 J 21.000 in'4 = 5.97 ln•3 1.410 in 7.700 in•3 = 11.900 ln•4 C 11.200 ln•3 = 5.970 ln•3 = 1.410 In Qualls Engineering Project Title: Army Navy Bridge Engineer: Jacob Farabaugh 4403 Manchester Ave, Suite 203 Encinitas, CA 92024 Project ID: 20199 Proiect Descr: t: (760) 652-9257 Steel Base Plate DESCRIPTION: SU Col Code References Calculations per AISC Design Guide# 1, IBC 2012, CBC 2013, ASCE 7-10 Load Combination Set : ASCE 7-16 General Information Material Properties AISC Design Method Allowable Strength Design Steel Plate Fy = 36 ksi n C : ASD Safety Factor. Concrete Support fc = 3 ksi Assumed Bearing Area f ull Bearing Column & Plate Column Properties Steel Section HSS4x4x1 /2 Depth 4in 4 in 0.465 in in Width Flange Thickness Web Thickness Plate Dimensions N:Length 12.0 in B : Width 12.0 In Thickness 1 in Column assumed welded to base plate Applied Loads D : Dead Load ....... L :Llve ....... Lr : Roof Live ....... .. S: Snow ............... . W:Wind .............. .. E : Earthquake ............ .. H : Lateral Earth ........ . p.y 2.70 k 14.30 k k k k k k Area lxx lyy Nominal Bearing Fp per JS 6.02 in~2 in~4 in~4 Support Dimensions Width along 'X' 60.0 in 60.0 in Length along ·r I -1 ------ V-Z k k k k k 1.039 k k M-X k-ft k-ft k-ft k-11 k-ft 9.351 k-ft k-ft • P ·=Gravity load,·+· sign is downward. ·+· Moments create higher soil pressure at +Z edge. • +· Shears push plate towards +Z edge. Anchor Bolts Anchor Bolt or Rod Description 1 1/2' Max of Tension or Pullout Capacity .......... . Shear Capacity ........................................ . Edge distance : bolt to plate .................. . Number of Bolts in each Row .................. . Number of Bolt Rows ....................... . k k 1.25 In 2 1 r -- I r --- +P _q 2.5 5.10ksi 1 '-0" z I [!J X 5> ~ s·-o· ~""""' . •-.--1 .._.,.. ...... . I • • . • . . Qualls Engineering 4403 Manchester Ave, Suite 203 Encinitas, CA 92024 t (760) 652-9257 Steel Base Plate ···•··, DESCRIPTION: Stl Col GOVERNING DESIGN LOAD CASE SUMMARY Plate Design Summary Design Method Allowable Strength Design +O+0. 70E+0.60H Project Title: Army Navy Bridge Engineer: Jacob Farabaugh Project ID: 20199 Proiect Descr: Ma : Max. Moment .................... . fb : Max. Bending Stress .............. . Fb : Allowable : Fy/Omega Govemlng Load Combination Goveming Load Case Type Goveming STRESS RA TIO Axial+ Moment, U2 < Eccentricity, Tension 01 Bending Stress Ratio 1.0 Design Plate Size Pa : Axial Load ... . Ma : Moment ....... . 1'-0" X 1'-0" X 1" 0.000 k 0.000 k-ft Load Comb. : +O+H Loading Pa : Axial Load .... Design Plate Height ........ . Design Plate Width ........ . Will Ile d1/forent from entry d pa,t,at bea11ng used A 1 : Plate Area ........ . A2: Support Area ................ .. sqrt( A2/A1 ) Distance for Moment Calculation • m' .................... . • n ..................... . x ............................. . Lambda .................... .. n' ....................................... . n· •Lambda ................................. . L = max(m, n, n") ........................ . Load Comb. : +D+L +H Loading Pa : Axial Load .... Design Plate Height ....... .. Design Plate Width ........ . w,11 oe d,fferent Iron• entry rl pan,at /Jlla11ng used A 1 : Plate Area ....... .. A2: Support Area ................. . sqrt( A2/A1) Distance for Moment Calculation ·m ..................... . • n • ····················· x ............................. . Lambda .................... .. n' ....................................... . n' •Lambda ................................. . L = max(m, n, n") ........................ . 2.700 k 12.000 In 12.000 In 144.000 in•2 3,600.000 1n•2 2.000 4.100 In 4.100 In 0.000 in•2 0.000 0.000 In 0.000 In 4.100 In 17.000 k 12.000 in 12.000 In 144.000 in•2 3,600.000 in•2 2.000 4.100 in 4.100 In 0.000 in•2 0.000 0.000 In 0.000 in 4.100 In fu : Max. Plate Bearing Stress .... F p : Allowable : Bearing Stress Ratio Bearing Stresses Fp : Allowable ............................. .. fa : Max. Bearing Pressure Strn, Ratio ...................... . Plate ~~~i~~;~~•Wt ............... . fb: Actual ............................... . Fb : Allowable ............................. . Strn, Ratio ................... .. Bearing Stresses F p : Allowable ............................. .. fa : Max. Bearing Pressure Strn , Ratio ..................... .. Plate ~~i~i;Yc.~5?~ .................. . lb: Actual ............................... . Fb : Allowable ............................. . StreH Ratio ................... .. 3.015 k-ln 12.061 ksl 21.557 ksi 0 560 Bending Stress OK 2.040 ksl 2.040 ksl 1.000 Bearing Stress OK /0 Axial Load Only, No Moment 2.040 ksi 0.019 ksl 0.009 0.158 k-ln 0.420 ksl 21.557 ksl 0.019 Axial Load Only, No Moment 2.040 ksi 0.118ksi 0.058 0.992 k-ln 2.646 ksi 21.557 ksl 0.123 Qualls Engineering 4403 Manchester Ave, Suite 203 Encinitas, CA 92024 t: (760) 652-9257 Steel Base Plate ···•··· DESCRIPTION: SU Col Load Comb. : +D+0.70E+0.60H ~ Pa : Axial Load .. .. Ma : Moment ...... .. Eccentricity ...................... .. A 1 : Plate Area ........ . A2. : Support Area .................... . sqrt( A2JA1) Calculate plate moment from bearing ... max(m, n) 'A' : Bearing Length Mpl : Plate Moment 2.700 k 6.546 k-ft 29.092 in 144.000 in'2 3,600.000 in"2 2.000 4.400 in 0.710 in 0.251 k-ln Load Comb. : +D+0.750L+0.750S+0.5250E+H Loading Pa : Axial Load .... Ma : Moment ........ Eccentricity ....................... . A 1 : Plate Area ........ . A2. : Support Area .................... . sqrt( A2JA1 ) Distance for Moment Calculation 'm' ................... .. • n • .................... . Load Comb. : +0.60D+0.70E+H Loading Pa : Axial Load .. .. Ma : Moment ...... .. Eccentricity ...................... .. A1 : Plate Area ........ . A2.: Support Area ................... .. sqrt( A2JA1) Calculate plate moment from bearing .. , max(m. n) 'A': Bearing Length Mpl : Plate Moment 13.425 k 4.909 k-ft 4.388 in 144.000 1n•2 3,600.000 ln'2 2.000 4.100 in 4.400 In 1.620 k 6.546 k-fl 48.487 in 144.000 in'2 3,600.000 in'2 2.000 4.400 in 0.669 in 0.238 k-ln Project Title: Army Navy Bridge Engineer: Jacob Farabaugh Project ID: 20199 ProJect Descr: I/ Printed 16 OCT 2020, 12 03PM Y avy e. Software copyright ENERCALC, INC. 1983-2020, Bulld:12.20.3.25 .. Axial Load+ Moment, Ecc. > U2 Calc~~~~~rW~~.~.~~.~.~~.~ension ... 2.996 k 0.000 k 0.000 Tension : Allowable ................... . Strtta Ratio ................... . Dist. from Bott lo Col. Edge ............ . Effective Boll Width for Bending ... .. Plate Moment from Boll Tension ..... .. Bearing Stresses Fp : Allowable .............................. . fa : Max. Bearing Pressure Strtta Ratio .................. .. Plate Bending Stresses Mmax ......................................... . lb : Actual .............................. .. Fb: Allowable ............................... . Strna Ratio .................. .. 2.850 In 11.400 in 1.498 k-ln 2.040 ksl ( set equal to Fp ) 1.000 3.015 k-ln 12.061 ksi 21.557 ksi 0.560 Axial Load+ Moment, Ecc. > U6 and Ecc. < U2 Bearing Stresses Fp : Allowable .............................. . fa : Max. Bearing Pressure Strell Ratio .................. .. Plate Bending Stresses Mmax1 = Fu • m•2 / 2 ............... .. Mmax2 = Fu • n'2 / 2 ................ .. Mmax ......................................... . fb : Actual .............................. .. Fb: Allowable ............................... . Streaa RaUo ................... . 2.040 ksi 0.186 ksl 0.091 1.389 k•in 0.540 k-ln 1.389 k-in 5.555 ksl 21.557 ksi 0.258 Axial Load+ Moment, Ecc. > U2 Calcu+~~~~a~;a~,~~~-~.~~.~.~~~.~ension ... 3.286 k 0.000 k 0.000 Tension : Allowable .................. .. Streu Ratio ................... . Dist. from Bolt to Col. Edge ............ . Effective Bolt Width for Bending .... . Plate Moment from Bolt Tension ...... . Bearing Stresses Fp : Allowable ............................. .. fa : Max. Bearing Pressure Streaa Ratio .................. .. Plate Bending Stresses Mmax ......................................... . fb : Actual .............................. .. Fb: Allowable ............................... . Strna Ratio .................. .. 2.850 in 11.400 In 1.643 k-ln 2.040 ksl ( set equal to Fp ) 1.000 2.852 k-in 11.407 ksl 21.557 ksl 0.529 SIMPSON StJ.'Ong'-Tie Anchor Designer™ Software Version 2.6.6703.3 1,Proiect Information Customer company: Customer contact name: Customer e-mail: Comment: 2, Input Pata & Anchor Paramet•CJ General Design method:ACI 318-14 Units: Imperial units Anchor Information: Anchor type: Cast-In-place Material: F1554 Grade 36 Diameter (inch): 1.000 Effective Embedment depth, ho1 (inch): 14.000 Anchor category: - Anchor ductility: Yes h""" (inch): 15.75 c""" (Inch): 1.44 Srr1n (inch): 4.00 Recommended Anchor Company: Qualls Engineering Engineer: Jacob Farabaugh Project: Anny Navy Bridge Address: Phone: E-mail: Project description: Location: Fastening description: Base Material Concrete: Normal-weight Concrete thickness, h (inch): 18.00 State: Cracked Compressive strength, fc (psi): 2500 4'c,v: 1.0 Reinforcement condition: B tension, B shear Supplemental reinforcement: Not applicable Reinforcement provided at comers: No Ignore concrete breakout in tension: No Ignore concrete breakout in shear: No Ignore 6do requirement: Yes Build-up grout pad: No Bast Plate I Date: I Length x Width x Thickness {inch): 12.00 x 12.00 x 1.00 Yield stress: 36000 psi Profile type/size: HSS4X4X1/2 Anchor Name: Heavy Hex Bolt -1"0 Heavy Hex Bolt, F1554 Gr. 36 f, ►l ~ I 1,< ~. I • \. I , • . , , ... ,, ... ., ..... , ................. ~······ I 1. I t.l,\.ll., 'I-I' L , , \ ~ q, ~, L I I,• I I ( l If t l f 110/14/2020 20199 Input data and results must be checked for agreement with the existing circumstances, the atandards and guidelines must be checked for plausibility. s,mpson Slrong•T1e Company Inc 5956 W. Las Posltas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.slronglie.com SIMPSON Strong-Tie • Load and Geometry Anchor Designer™ Software Version 2.6.6703.3 Load factor source: ACI 318 Section 5.3 Load combination: not set Seismic design: No Anchors subjected to sustained tension: Not applicable Apply entire shear load at front row: No Anchors only resisting wind and/or seismic loads: Yes Strength level loads: Nuo [lb]: -14500 Vuox [lb]: 0 Vuoy [lb): 1200 Mux [ft-lb): 15000 Muy [ft-lb]: 0 Muz [ft-lb): 0 <Figure 1> Company: Qualls Engineering I Date: I 10/14/2020 Engineer: Jacob Farabauszh I Project: Anny Navy Bridsze 20199 Address: Phone: E-mail: 145001b 2001b 0 ft-lb Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong-T,e Company Inc 5956 W. Las Posltas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtle.com SIMPSON <Figure 2> Anchor Designer™ Software Version 2.6.6703.3 Companv: Engineer: Project: Address: Phone: E-mail: Qualls En£ineerin£ I Date: I 10/14/2020 Jacob Farabaugh I Army Navy Bridge 20199 Input dsta end results must be checked for egreemenl with the existing circumstances, the standards end guidelines must be checked for pleuslblllty. Simpson Strong-Tie Company Inc 5956 W. Les Posltas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fex: 925.847.3871 www.strongtie.com IY SIMPSON Strong-Tie • Anchor Designer™ Software Version 2.6.6703.3 3, Ruuttlna Anchor Force, Companv: Enolneer. Prolect: Address: Phone: E-mail: Anchor Tension losd, N,.(lb) Shear load x, V,~ (lb) 1 0.0 2 6872.5 3 6872.5 4 0.0 Sum 13744.9 Maximum concrete compression strain (%o): 0.23 Maximum concrete compression stress (psi): 997 Resultant tension fores (lb): 13745 Resultant compression fores (lb): 28247 0.0 0.0 0.0 0.0 0.0 Eccentricity of resultant tension forces In x-axis, e'"" (Inch): 0.00 Eccentricity of resultant tension forces In y-axis, e•., (Inch): 0.00 Eccentricity of resultant shear forces In x-axis, e'v. (Inch): 0.00 Eccentricity of resultant sheer forces In y-axis, e'v, (Inch): 0.00 4, Steel Strenath of Anchor In Tention (Sac, 17,4,1) Nu (lb) ¢ ,!Nu (lb) 35150 0.75 26363 5, Conct1t1 Breakout Stttneth of Anchor In J101lon (Sec. 17,4,2) No• 16-1,✓f,h,l"(Eq. 17.4.2.2b) ,I, r, (psi) het(ln) N, (lb) 1.00 2500 14.000 65058 ;N,.. •,p (AN<I AM»)'P"·""'"'·"%.N'P,,,.NN, (Sec. 17.3.1 & Eq. 17.4.2.1b) ANc (ln2) ANc:o (ln2) c •. m.., (in) 'P,c,N 'PH.N Y'c.N 2050.00 1764.00 20.00 1.000 0.986 1.00 8, Pullout Stmnath ef Anchor In Janalon (Soc, 17,◄,3) ,pN,, • (,'P,.,N, • (,'PcP8A..,r, (Sec. 17.3.1, Eq.17.4.3.1 & 17.4.3.4) 'f'cp A.., (in') r, (psi) ¢ ;N,,. (lb) 1.0 1.50 2500 0.70 21014 • "•alls =gmeenng I Oats: 110/14/2020 Jacob Farabaugh I Anny Navy Bridge 20199 Shear load y, Shear load combined, V,.,(lb) ✓(V-)'+(V,.,)' (lb) 300.0 300.0 300.0 300.0 300.0 300.0 300.0 300.0 1200.0 1200.0 <Figure 3> 01 02 T 04 03 lflep.N N, (lb) ;N.,, (lb) 1.000 65058 0.70 52168 Input data end results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. S1mp5on S\rony·T1e Company Inc 5956 W. Las F'osltas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strcngtie.com 15 SIMPSON Anchor Designer™ Software Company: Qualls En1tineerin1t Engineer: Jacob Farabau2h Strong•Tie Project: Armv Navv Brid2e • Version 2.6.6703.3 Address: Phone: E-mail: 8, Staal Strenath of Anchor In Shear (Sac, 17,5,1) Vu (lb) ;,,..,, ; ;..,.,;Vu (lb) 21090 1.0 0.65 13709 9. Concr:,ta Brtakaut Stranath of Anchor In Sh11r (Sac, 17,5,2) Shur perpendicular to edge In y-dlrecllon: Vby = mlnl7(1./ d.)0·2✓d.A.✓fcC•1 U; 9A.✓rcc.1UI (Eq. 17.5.2.28 & Eq. 17 .5.2.2b) /, (in) d, (In) ,i, r, (psi) c .. (in) v., (lb) 8.00 1.000 1.00 2500 17.33 32474 tpVCJJgy = tp (Ave/ Avco) Y"K.VY"ed.vY'c.V'f'h,VVol' (Sec. 17 .3.1 & Eq. 17 .5.2.1b) Ave (ln2) Aveo (ln2) 'Pee.I/ V'.a.v 'l'r;,v ¥'11.v 1080.00 1352.00 1.000 1.000 1.000 1.202 Shur parallel lo edge In y-dlrecllon: Vbi = minl7(1e/ d,)0·2✓d,A,✓fcCa11·5; 9A.✓fcc.,1·51 (Eq. 17.5.2.2a & Eq. 17.5.2.2b) I, (in) d, (In) A, r, (psi) c., (in) v., (lb) 8.00 1.000 1.00 2500 21.33 44341 ;v..., = ; (2)(Avd Av~) 1",,vl",.,vl",.vl",.vV"' (Sec. 17.3.1, 17.5.2.1(c) & Eq. 17.5.2.1b) Ave (in2) Avoo (in2) 'f'ec.v 'Ped,V 'Pc.v 'P1,,v 1080.00 2048.00 1,000 1.000 1.000 1.333 10 Concr:m Prvout Strenath of Anchor In Shear (Sec, 17,5,3) ¢Vr,pg = (/JkcpNwg = r/Jkcp(ANcf ANeo)Y'•c.N 'l'ec1.N'l'c,N'f'ep,NNri(Sec. 17 .3.1 & Eq. 17 .5.3.1 b) kep ANe (in2) ANco (in2) 'f'.c.N 'f'9li.N Y'c.N 1/Jep.N 2.0 2450.00 1764.00 1.000 0.986 1.000 1.000 11, Re1ulta Interaction ofT1n1ll1 and Shear Force, (Sec, 17,6,) Tension Factored Load, Nu• (lb) Steel 6872 Concrete breakout Pullout Shear Steel T Concr•t• breakout y+ II Concrete breakout X• Pryout Interaction check Sec. 17.6 .. 1 0.33 13745 6872 Factored Load, Vua (lb) 300 1200 800 1200 0.00 Design Strength, eNn (lb) Ratio 26363 0.26 52168 0.26 21014 0.33 Design Strength, eVn (lb) Ratio 13709 0.02 21824 0.05 43848 0.01 124695 0.01 Combined Ratio 32.7% V,, (lb) 32474 V.,(lb) 44341 N, (lb) 65058 Permissible 1.0 1"1!1 Heavy Hex Bolt, F1554 Gr. 36 with hef • 14.000 Inch meets Iha ■elected design criteria. I Date: 110/14/2020 I 20199 ;V...,(lb) 0.70 21824 0.70 43648 ;v.,,, (lb) 0.70 124695 Status Pass Pass Pan (Governs) Status Pass P•-(Governa) Pan (Governs) Pass Status Pass Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson S!ronu•T1~ Compemy 111c 5956 W. Las ?osltas Boulevard Pleasanton, CA 94588 ?hone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com SIMPSON Strong-Tie • Anchor Designer™ Software Version 2.6.6703.3 Bau Plata Thlckna11 Required base plate thickness: 1.096 Inch Company: Onalls Engineenng Enolneer: Jacob Farabauah Prolect: Annv Navv Brid2e Address: Phone: E-mail: Warning: input base plate thickness does not meet required base plate thickness. 12, Wamlna, I Date: 110/14/2020 I 20199 -Minimum spacing and edge distance requirement of 6da per ACI 318 Sections 17. 7 .1 and 17. 7 .2 for torqued cast-in-place anchor is waived per designer option. -Designer must exercise own judgement to determine if this design Is suitable. Input data and results must be checked for agreement with the existing clrcumstancea, the standards and guidellnes must be checked for plausibility. S,mpson Stronii-fie Company Inc 5956 W. Laa Positas Boulevard Pleasanton, CA 94588 f>hone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com 17 Qualls Engineering 4403 Manchester Ave, Suite 203 Encinitas, CA 92024 t: (760) 652-9257 General Footing ···•··. DESCRIPTION: Col Footing Code References Calculations per ACI 318-11 , IBC 2012, CBC 2013, ASCE 7-10 Load Combinations Used : ASCE 7-16 General Information Material Properties fc : Concrete 28 day strength ~ : Rebar Yield c : Concrete Elastic Modulus Concrete Density cp Values Flexure Shear Analysis Setting~ Min Steel % Bending Reinf. Min Allow % Temp Reinf. Min. Overturning Safety Factor Min. Sliding Safety Factor Add Ftg Wt for Soll Pressure Use ftg wt for stability, moments & shears Add Pedestal Wt for Soil Pressure Use Pedestal wt for stability, mom & shear Dimensions Width parallel to X-X Axis = Length parallel to Z-Z Axis = Footing Thickness = Load location offset from footing center ... ez : Prll to Z-Z Axis = Pedestal dimensions ... px : parallel to X-X Axis pz : parallel to Z-Z Axis Height = = = Rebar Centertine to Edge of Concrete ... at Bottom of footing = Reinforcin Bars parallel to X-X Axis Number of Bars Reinforcing Bar Size Bars parallel to Z-Z Axis = = Number of Bars = Reinforcing Bar Size = = = = = = = Bandwidth Distribution Check (ACI 15.4.4.2) Direction Requiring Closer Separation # Bars required within zone # Bars required on each side of zone A lied Loads P : Column Load = OB : Overburden = M-xx = M-zz = V-x = V-z = # # D 2.0 ksi 60.0 ksi 3,122.0 ksi 145.0 pct 0.90 0.750 = = 0.00180 = = 5.0 ft 5.0 ft 18.0 in 18 in in In in In 3.0 in 7.0 5 7.0 5 n/a n/a n/a 1.0 : 1 1.0 : 1 Yes Yes No No . . Lr 2.70 Project Title: Army Navy Bridge Engineer: Jacob Farabaugh Project ID: 20199 ProJect Descr: 1i Soil Design Values 2.0 ksf Allowable Soil Bearin~ = Increase Bearing By coting Weight = No Soil Passive Resistance (for Sliding) = 200.0 pct Soil/Concrete Friction Coeff. = 0.350 Increase, based on footing Depth Footing base depth below soil surface = 1.50 ft Allow press. increase per foot of depth = 0.10 ksf when footing base Is below = 1.0 ft Increase, based on footing plan dimension Allowable pressure increase per foot of depth = 0.10 ksf when max. length or width is greater than 2.0 ft = .. ···•-~ __ _..±i__J L s w E H 14.30 k ksf 9.351 k-ft 9.351 k-ft k 1.040 k Qualls Engineering 4403 Manchester Ave, Suite 203 Encinitas, CA 92024 Project Tltle: Army Navy Bridge Engineer: Jacob Farabaugh Project ID: 20199 Proiect Descr: I q t (760) 652-9257 Printed· 16 OCT 2020 12·03PM General Footing Sollwn y r,y . ENERCAI.C, INC. 11183-2020, 6"1~:12.2().3.25 ,11• • • DESCRIPTION: Col Footing ==-'-'--------------------------...J-•1¥1•1■8•) --DESIGN SUMMARY Mln.Rltlo PASS 0.9413 PASS 1.916 PASS 1.665 PASS n/a PASS 3.893 PASS nla PASS 0.1164 PASS 0.1164 PASS 0.04993 PASS 0.05469 PASS 0.1082 PASS 0.1082 PASS n/a PASS 0.04458 PASS 0.2028 Detailed Results Soil Bearin Rotation Axil & Load Combination ... X-X. +D+H X-X. +D+L+H X-X. +D+0.70E+0.60H Item Soil Bearing Overturning -X-X Overturning -Z-Z Sliding • X-X Sliding· Z-Z Uplift Z Flexure (+X) Z Flexure (-X) X Flexure (+Z) X Flexure (-Z) 1-way Shear (+X) 1-way Shear (-X) 1-way Shear ( +Z) 1-way Shear (-Z) 2-way Punching Groll Allowable X-X. +D+0.750L +0.750S+0.5250E+H X-X. +0.80D+0.70E+H 2.350 2.350 2.350 2.350 2.350 2.350 2.350 2.350 2.350 2.350 Z-Z. +D+H Z-Z. +D+L+H Z-Z. +D+0.70E+0.60H Z-Z. +D+0.750L+0.750S+0.5250E+H Z-Z. +0.80D+0.70E+H Overturning Stability Rotation Axl1 & Load Combination ... X-X. +D+H X-X. +D+L+H X-X. +D+0.70E+0.60H X-X. +D+0.750L +0.750S+0.5250E+H X-X. +0.80D+0.70E+H Z-Z. +D+H z.z, +D+L+H Z-Z. +D+0.70E+0.60H Z-Z. +D+0.750L +0.750S+0.5250E+H Z-Z. +0.60D+0.70E+H Sliding Stability Force Application Axl1 Load Combination ... X-X. +D+H X-X. +D+L+H X-X. +D+0.70E+0.80H X-X. +D+0.750L +0.750S+0.5250E+H X-X. +0.60D+0.70E+H Z-Z. +D+H Z-Z. +D+L+H Z-Z. +D+0.70E+0.60H Z-Z. +D+0.750L+0.750S+0.5250E+H Z-Z. +0.60D+0.70E+H Appllld 2.212 ksf 7.638 k-ft 6.546 k-ft 0.0 k 0.7260 k 0.0 k 3.265 k-ft/ft 3.265 k-ft/ft 1.401 k-ft/ft 1.534 k-ft/ft 7.256 psi 7.256 psi 0.0 psi 2.991 psi 27.208 psi Xecc n/a nla n/a n/a n/a 0.0 0.0 9.653 3.123 16.088 Zecc (in) 5.972 13.638 17.235 16.455 24.744 n/a n/a n/a n/a n/a Overturning Moment None None 7.638 k-ft 5.728 k-ft 7.638 k-ft None None 6.546 k-ft 4.909 k-ft 6.546 k-ft Sliding Fore■ 0.0 k 0.0 k 0.0 k 0.0 k 0.0 k 0.0 k 0.0 k 0.7280 k 0.5460 k 0.7280 k Capacity 2.350 ksf 14.636 k-ft 12.206 k-ft 0.0 k 2.834 k 0.0 k 28.049 k-ft/ft 28.049 k-ft/11 28.049 k-ft/11 28.049 k-ft/11 67.082 psi 67.082 psi 67.082 psi 67.082 psi 134.164 psi Govom1nv Load Combination +D+0.750L +0.750S+0.5250E+H about X +0.60D+0.70E+H +0.60D+0.70E+H No Sliding +0.60D+0.70E+H No Uplift +1.20D+0.50Lr+1.60L +1.60H +1.20D+0.50Lr+1.80L +1.60H +1.20D+0.50Lr+1.60L +1.60H +0.90D+E+0.90H +1.20D+0.50Lr+1.60L +1.60H +1.20D+0.50Lr+1.60L +1.60H n/a +0.90D+E+0.90H +1.20D+0.50Lr+1.60L +1.60H Actual Soll Bearing Simi f Location Actual / Allow Bottom, -Z Top, +Z Le , -X Right, +X Ratio 0.1330 0.5180 n/a nla 0.220 0.0 2.181 n/a n/a 0 928 0.0 1.012 n/a n/a 0.431 0.0 2.212 n/a n/a 0.941 0.0 1.458 n/a n/a 0 620 n/a n/a 0.3255 0.3255 0 139 n/a n/a 0.8975 0.8975 0 382 n/a n/a 0.01445 0.6366 0.271 n/a n/a 0.5212 0.9878 0 420 n/a n/a 0.0 0.5575 0.237 Resisting Moment Stsblllty Ratio Ststu1 24.394 k-ft lnfinltv OK 81.594 k-ft lnfinltv OK 24.394 k-ft 3.194 OK 67.294 k-ft 11.746 OK 14.636 k-ft 1.916 OK 0.0 k-ft lnfinltv OK 0.0 k-ft infinltv OK 20.344 k-ft 3.108 OK 47.156 k-ft 9.608 OK 12.206 k-ft 1.865 OK All units k ReallUng Force Stability Ratio Ststus 3.973 k No Slldlna OK 8.978 k No Siidlna OK 3.973 k No Slidlna OK 7.727 k No Slldina OK 2.834 k No Slidina OK 3.973 k No Slidina OK 8.978 k No Slldina OK 3.973 k 5.458 OK 7.727 k 14.152 OK 2.834 k 3.893 OK Qualls Engineering 4403 Manchester Ave, Suite 203 Encinitas, CA 92024 t (760) 652-9257 General Footing 1.11· • DESCRIPTION: Col Footing Footing Flexure Fltxurt Axlt & load Comblnlllon X-X. •1.400+1.60H X-X. •1.40D+1.60H X-X. +1.20D+0.50Lr+1.60L +1.60H X-X. +1.20D+0.50Lr+1.60L +1.60H X-X. +1.20D+1.60L +0.50S+1.60H X-X. +1.200+1.60L +0.50S+1.60H X-X. +1.20D+L +0.20S+E+1.60H X-X. +1.20D+L +0.20S+E+1.60H X-X. +0.90D+E+0.90H X-X. +0.90D•E+0.90H Z-Z. +1.40D+1.60H Z-Z. +1.40D+1.60H Z-Z. +1.20D+0.50Lr+1.60L +1.60H Z-Z. +1.20D+0.50Lrt1 .60L +1.60H Z-Z. +1.200+1.60L +0.50S+1.60H Z-Z. +1.20D+1.60L +0.50S+1.60H Z-Z. +1.20D+L +0.20S+E+1.60H Z-Z. +1.20D+L +0.20S+E+1.60H Z-Z. +0.90D+E+0.90H Z-Z. +0.90D+E+0.90H One Way Shear Load Combination ... +1.400+1.60H +1.20D+0.50Lr+1.60L+1.60H +1.20D+1.60L +0.50S+1.60H +1.20D+L +0.20S+E+1.60H +0.90D+E+0.90H Two-Way "Punching" Shear Load Combination ... +1.40D+1.60H +1.20D+0.50Lr+1.60L +1.60H +1.20D+1.60L+0.50S+1.60H +1.20D+L +0.20S+E+1.60H +0.90D+E+0.90H Project TIiie: Army Navy Bridge Engineer: Jacob Farabaugh Project ID: 20199 ProJect Descr: Printed 16 OCT 2020. 12.03PM _,, copyright ENERCALC, INC. 1983-2020, Build: 12.20.3.25 •• Side TtMlon Al Rlq'd Gvm.AI Ac:tualAI PhrMn Statut k-ft Surface ln"2 ln"2 in"2 k-ft 0.1935 +Z Bottom 0.3888 Min Temp% 0.4340 28.049 OK 0.1936 .z Bottom 0.3888 Min Temp% 0.4340 28.049 OK 1.401 +Z Bottom 0.3888 Min Temp% 0.4340 28.049 OK 1.401 .z Bottom 0.3888 Min Temp% 0.4340 28.049 OK 1.401 +Z Bottom 0.3888 MlnTemo% 0.4340 28.049 OK 1.401 .z Bottom 0.3888 MinTemo% 0.4340 28.049 OK 1.356 +Z Bottom 0.3888 MlnTemo% 0.4340 28.049 OK 0.8256 .z Too 0.3888 MlnTemo% 0.4340 28.049 OK 0.8480 +Z Bottom 0.3888 MinTemo% 0.4340 28.049 OK 1.534 .z Too 0.3888 Min Temp% 0.4340 28.049 OK 0.4725 -X Bottom 0.3888 Min Temo% 0.4340 28.049 OK 0.4725 +X Bottom 0.3888 MlnTemo% 0.4340 28.049 OK 3.265 -X Bottom 0.3888 MlnTemo % 0.4340 28.049 OK 3.265 +X Bottom 0.3888 MinTemo % 0.4340 28.049 OK 3.285 -X Bottom 0.3888 MinTemo% 0.4340 28.049 OK 3.265 +X Bottom 0.3888 MlnTemo% 0.4340 28.049 OK 1.257 -X Bottom 0.3888 Min Temo % 0.4340 28.049 OK 3.128 +X Bottom 0.3888 MlnTemo% 0.4340 28.049 OK 0.5537 -X Too 0.3888 Min Temp% 0.4340 28.049 OK 1.316 +X Bottom 0.3888 MinTemo% 0.4340 28.049 OK Vu@•X Vu@+X Vu@.Z Vu@+Z Vu:Max PhlVn Vu/Phl'Vn Statu1 1.05osi 1.05psl 0.44 PSI 0.00 psi 1.05osi 67.08 osi 0.02 OK 7.26osi 7.26osl 2.50 osi 0.00 osi 7.26osi 67.08 osl 0.11 OK 7.26DSi 7.26osi 2.50 DSI 0.00 osi 7.26osi 67.08 osi 0.11 OK 2.53DSi 7.21 osi 2.77 osl 0.00 osi 7.21 osi 67.08 osi 0.11 OK 1.36DSi 3.24osi 2.99 osi 0.00 osl 3.24osi 67.08 psi 0.05 OK All units k Vu Phl'Vn Vu/ Phl'Vn Stalul 3.94 osi 134.16osi 0.02935 OK 27.21 osi 134.16osi 0.2028 OK 27.21 osi 134.16osi 0.2028 OK 17.81 osi 134.16osi 0.1328 OK 2.04 osi 134.16osi 0.01521 OK □ □ □ □ □ □ □ □ □ □ ENCINA WASTEWATER AUTHORITY INDUSTRIAL WASTEWATER DISCHARGE PERMIT SCREENING SURVEY 6200 Avenida Encinas, Carlsbad, CA 92011 Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinajpa.com Date: 11/06/2020 Business Name: __ A_r_m_y_a_n_d_N_a_v_y_A_c_a_d_e_m_Y _________ _ Street Address: 2605 Carlsbad Blvd., Carlsbad CA 92008 Email Address: JPullen@armyandnavyacademy.org PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT: (ON REVERSE SIDE CHECK TYPE OF BUSINESS) I ■I Check all below that are present at your facility: Acid Cleaning D Food Processing D Metal Powders Forming Assembly D Glass Manufacturing D Nutritional Supplement/Vitamin Automotive Repair 0 Industrial Laundry D Manufacturing Battery Manufacturing D Ink Manufacturing D Painting/Finishing Biofuel Manufacturing O Laboratory D Paint Manufacturing Biotech Laboratory 0 Machining/Milling D Personal Care Products Bulk Chemical Storage D Membrane manufacturing D Manufacturing Car Wash D (i.e. waterfilter membranes) D Pesticide Manufacturing/ Packaging Chemical Manufacturing O Metal Casting/Forming D Pharmaceutical Manufacturing Chemical Purification D Metal Fabrication D (including precursors) D Dental Offices D Metal Finishing D Porcelain Enameling D Dental Schools D Electroplating D Power Generation D Dental Clinics D Electroless Plating 0 Print Shop 0 Dry Cleaning D Anodizing D Research and Development D Electrical Component 0 Coating (i.e. phosphating) D Rubber Manufacturing □ Manufacturing D Chemical Etching/Milling D Semiconductor Manufacturing □ Fertilizer Manufacturing D Printed Circuit Board D Soap/Detergent Manufacturing □ Film/ X-ra y Processing D Manufacturing D Waste TreatmenVStorage New Business? YesONoil SIC Code(s) if known: ______ Date operation began/will begin: ______ _ Tenant Improvement? Yes ONo■ If yes, briefly describe improvement: __________________ _ Description of operations generating wastewater (discharged to sewer, hauled or evaporated): __________ _ Preparation and installation of structural concrete for foundations. Preparation and installation of exterior stucco finish systems for building cladding. Estimated volume of industrial wastewater to be discharged (gal/ day) : _____________________ _ List hazardous wastes generated (type/volume): _____________________________ _ Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authority? YesOoate: ______ .No□ Page 1 of 2 ENCINA WASTEWATER AUTHORITY INDUSTRIAL WASTEWATER DISCHARGE PERMIT SCREENING SURVEY 6200 Avenida Encinas, Carlsbad, CA 92011 Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinajpa.com The commercial enterprises listed below are a partial listing of businesses that are exempt from industrial wastewater discharge permitting under normal operating conditions. They are exempt because (a) they discharge no process wastewater (i. e., they only discharge sanitary wastewater with no pollutants exceeding any local limits ), and (b) they have no potential to negatively impact the EWPCF or other wastewater treatment plants in the ESS. Any questions regarding exemptions should be referred to EWA Source Control staff. □ Automobile Detailer s □ Hotels/ Motels (no laundry) □ Barber/Beauty Shops □ Laundromats □ Business/Sales Offices □ Libraries □ Cleaning Services □ Medical Offices (no x-ray developing) □ Carpet/Upholstery □ Mortuaries □ Childcare Facilities □ Museums □ Churches □ Nail Salons □ Community Centers □ Nursing Homes □ Consulting Services □ Office Buildings (no process flow) □ Contractors □ Optical Services □ Counseling Services □ Pest Control Services (no pesticide repackaging for sale) 1-1 Educational Services (no auto repair/film developing) □ Pet Boarding/Grooming Facilities □ Financial Institutions/Services □ Postal Services (no car wash/auto repair) □ Fitness Centers □ Public Storage Facilities □ Gas Stations (no car wash/auto repair) □ Restaurants/Bars □ Grocery Stores (no film developing) □ Retail/Wholesale Stores (no auto repair/film □ Residential based Businesses developing) □ Theaters (Movie/Live) CERTIFICATION STATEMENT I certifv that the information above is true and correct to the best o.fmy knowledge. --0#~,c../~~-~ Signature: _____________ _ Print Name: Douglas Paterson Architect Date: 11/06/2020 Facility Contact:_J_a_n_e_t_P_u_l_le_n _____ _ Title: Vice President, Finance and Operations ENCINA WASTEWATER AUTHORITY 6200AVENIDA ENCINAS, CARLSBAD, CA Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinajpa.com Page 2 of2 ( City of Carlsbad PURPOSE CLIMATE ACTION PLAN CONSISTENCY CHECKLIST 8-50 Development Services Building Division 1635 Faraday Avenue (760) 602-2719 www.carlsbadca.gov This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their projects. The completed checklist must be included in the building permit application. It may be necessary to supplement the completed checklist with supporting materials, calcu lations or certifications, to demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach to comply with energ y-related measures will need to attach to this checklist separate calculations and documentation as specified by the ordinances. NOTE: The following type of permits are not required to fill out this form ❖ Patio I ❖ Decks I ❖ PME (w/o panel upgrade) I ❖ Pool ...1111 If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, an explanation must be provided to the satisfaction of the Building Official. ...1111 Details on CAP ordinance requirements are available on the city's website . ...1111 A CAP Building Plan template (form B-55) shall be added to the title page all building plans. This template shall be completed to demonstrate project compliance with the CAP ordinances. Refer to the building application webpage and download the latest form. Project Name/Building Permit No.: Property Address/APN: Applicant Name/Co.: Applicant Address: Contact Phone: Army and Navy Academy /' Q( ..-, D __ Br_id--=gc....e_R_e_co_n_s_tru_c_ti_on_Pr_o~je_ct _______ BP No.: (_ J) 20 t-O-QL{l(_-, 2605 Carlsbad Blvd., Carlsbad CA 92008 APN 203-041-01 Douglas Paterson Architect 4653 Carmel Mountain Rd. Suite 308/305 San Diego CA 92008 858-200-6864 Contact Email: dwrpaterson@gmail.com Contact information of person completing this checklist (if different than above): Name: Company name/address: Douglas Paterson Architect 4653 Carmel Mountain Rd . Suite 308/305 San Diego CA 92008 Contact Phone: 858-200-6864 Contact Email: dwrpaterson@gmail.com ., .... ..-),//~-,,,:....L.._ __ --,. 11 /6/2020 Applicant Signature: __ ,,.,_......,...,_,,v_il_ M,v_v __________ Date: __ o _____ _ 8-50 Page 1 of 6 Revised 06/18 City of Carlsbad Climate Action Plan Consistency Checklist Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project. For alterations and additions to existing buildings, attach Build ing Permit Valuation worksheet. Building Permit Valuation (BPV) from worksheet: $ 5l?: S:S-S-- I Construction Type I Complete Sectlon(s) I Notes: I A high-rise residential building is 4 or more stories, including a Ii] Residential □ New construction ■ Additions and alterations: □ BPV < $60,000 □ BPV ~ $60,000 □ Electrical service panel upgrade only ~ BPV ~ $200,000 ~nresidential □ New construction ~ Alterations: □ BPV ~ $200,000 or additions ~ 1,000 square feet □ BPV ~ $1 ,000,000 □ ~ 2,000 sq. ft. new roof addition 1. Energy Efficiency Low-rise High-rise mixed-use building in which at least 20% of its conditioned floor area is residential use 2A, 3A, 18, 28, 4A 38, 4A N/A N/A All residential additions and alterations 1A, 4A 4A 1-2 family dwellings and townhouses with attached garages only *Multi-family dwellings only where interior finishes are removed 1A, 4A* 1B,4A* and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed 1 B, 28, 38, 48 and 5 lv!At Li=kl _or)K n 18, 5 18,28,5 Building alterations of~ 75% existing gross floor area 28,5 18 also applies if BPV ~ $200,000 Please refer to Carlsbad Municipal Code (CMC) sections 18.21.155 and 18.30.190, and the California Green Building Standards Code (CALGreen) for more information when completing this section. A Iii Residential addition or alteration l!: $60,000 building permit valuation. □ N/A ________ _ See CMC section 18.30.190. D Exception: Home energy score~ 7 (attach certification) Year Built Single.family Requirements Multi.family Requirements □ Before 1978 Select one: [] Duct sealinq □ Attic insulation C Cool roof □ Attic insulation □ 1978 and later Select one: [] Lighting package Cl Water heating Package □ Between 1978 and 1991 Select one: □ Duct sealinq □Attic insulation t::ICool roof • 1992 and later Select one: □Lighting package □Water heating package B. D Nonresidential* new construction or alterations l!: $200,000 building permit valuation, or additions l!: 1,000 square feel 0 NIA Updated 8/15/2019 ' 2 City of Carlsbad Climate Action Plan Consistency Checklist See CMC 18.21.155 and CALGreen Appendix AS, Division AS.2-Energy Efficiency. A5.203.1.1 Choose one: a .1 Outdoor lighting □ .2 Warehouse dock seal doors a .3 Restaurant service water heating (comply with California Energy Code section 140.5, as amended) □ N/A ________ _ [] .4 Daylight design PAFs □ .5 Exhaust air heat recovery A5.203.1.2.1 Choose one as applicable: t).95 Energy budget 0,90 Energy budget □NIA A5.211.1** □ On-site renewable energy □ N/A A5.211.3 .. □ Green power (if offered by local utility provider, 50% minimum renewable sources) □ N/A A5.212.1 D Elevators and escalators □ N/A A5.213.1 D Steel framing □ N/A • Includes hotels/motels and high-rise residential buildings •• For alterations~ $1 ,000,000 BPV and affecting > 75% existing gross floor area, or alterations that add 2,000 square feet of new roof addition: comply with CMC 18.30.130 instead. 2. Photovoltaic Systems A. D Residential new construction (for low-rise residential building permit applications submitted after 1/1/20). Refer to 2019 California Energy Code section 150.1(c)14 for requirements. Notes: 1) High-rise residential buildings are subject to nonresidential photovoltaic requirement (28 below) instead. 2) If project includes installation of an electric heat pump water heater pursuant to CMC 18.30.150(8) (high-rise residential) or 18.30.170(8) (low-rise residential), increase system size by .3kWdc if PV offset option is selected. Floor Plan ID (use additional CFA #d.u. Calculated kWdc* sheets if necessary) Total System Size: kWdc = (CFAx.572) / 1,000 + (1. 15 x #d.u.) *Formula calculation where CFA = conditional floor area, #du= number of dwellings per plan type If proposed system size is less than calculated size, please explain. Exception D D D D kWdc 8. D Nonresidential new construction or alterations ~$1,000,000 8PVand affecting ~75% existing floor area, or addition that increases roof area by ~,000 square feet Please refer to CMC section 18.30.130 when completing this section. Note: This section also applies to high-rise residential and hotel/motel buildings. Choose one of the following methods: □ Gross Floor Area (GFA) Method GFA: Olf < 10,000s.f. Enter: 5 kWdc Min. System Size: □If ~ 10,000s.f. calculate: 15 kWdc x (GFN10,000) •• kWdc **Round building size factor to nearest tenth, and round system size to nearest whole number. □ Time-Dependent Valuation Method Updated 8/15/2019 3 City of Carlsbad Climate Action Plan Consistency Checklist Annual TDV Energy use:••• ______ x .80= Min. system size: _____ kWdc ••• Attach calculation documentation using modeling software approved by the California Energy Commission. 3. Water Heating A O Residential and hotel/motel new construction Please refer to CMC sections 18.30.150 and 18.30.170 when completing this section. D For systems serving individual dwelling units choose one: D Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise residential only) D Heat pu mp water heater AND PV system .3 kWdc larger than required in CMC section 18.30.130 (high rise residential hotel/motel) or CA Energy Code section 150.1 (c) 14 (low-rise residential) D Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher D Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors D Exception: D For systems serving multiple dwelling units, install a central water-heating system with all of the following: D Gas or propane water heating system D Recirculation system per CMC 18.30.150(8) (high-rise residential, hotel/motel) or CMC 18.30.170(8) (low- rise residential) D Solar water heating system that is either: D .20 solar savings fraction D .15 solar savings fraction, plus drain water heat recovery D Exception: B. 0 Nonresidential new construction Please refer to Carlsbad Ordinance CMC section 18.30.150 when completing this section. D Water heating system derives at least 40% of its energy from one of the following (attach documentation): □ Solar-thermal D Photovoltaics D Recovered energy □Water heating system is (choose one): □ Heat pump water heater □ Electric resistance water heater(s) □Solar water heating system with .40 solar savings fraction □Exception: Updated 8/15/2019 4 City of Carlsbad Climate Action Plan Consistency Checklist 4. Electric Vehicle Charging A D Residential New construction and major alterations* Please refer to Carlsbad Ordinance CMC section 18.21.140 when com One and two-family residential dwelling or townhouse with attached garage: D One EVSE Ready parking space required D Exception : l!!!IIMulti-family residential· D Exception · Total Parking Spaces EVSE Spaces Proposed Caoable I Ready I I I Calculations: Total EVSE spaces= .10 x Total parking (rounded up to nearest whole number) EVSE Installed = Total EVSE Spaces x .50 (rounded up to nearest whole number) EVSE other= Total EVSE spaces -EVSE Installed (EVSE other may be "Capable," "Ready" or "Installed.") Installed I Total I *Major alterations are: (1) for one and two-family dwellings and townhouses with attached garages, alterations have a building permit valuation;;: $60,000 or indude an electrical service panel upgrade; (2) for multifamily dwellings (three units or more without attached garages), alterations have a building permit valuation ;;: $200,000, interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed. B D Nonresidential new construction (includes hotels/motels) D Exception · Total Parking Spaces EVSE Soaces Proposed Caoable I Ready I Installed 1 Total I I I Calculation· Refer to the table below· Total Number of ParkinQ Spaces provided Number of reQuired EV Spaces Number of reQuired EVSE Installed Spaces □ 0-9 1 1 D 10-25 2 1 D 26-50 4 2 D 51-75 6 3 □ 76-100 9 5 D 101-150 12 6 D 151-200 17 9 r1 201 and over 10 percent of total 50 oercent of Reauired EV Spaces Updated 8/15/2019 5 City of Carlsbad Climate Action Plan Consistency Checklist 5. D Transportation Demand Management (TDM): Nonresidential ONLY An approved Transportation Demand Management (TOM) Plan is required for all nonresidential projects that meet a threshold of employee-generated ADT. City staff will use the table below based on your submitted plans to determine whether or nor your permit requires a TOM plan. If TOM is applicable to your permit, staff will contact the applicant to develop a site-specific TOM plan based on the permit details. Office (all)2 20 Restaurant 11 Retaib 8 Industrial 4 Manufacturing 4 Warehousin 4 1 Unless otherwise noted, rates estimated from /TE Trip Generation Manual, 10th Edition 13 11 4.5 3.5 3 1 2 For all office uses, use SAN DAG rate of 20 ADT/1,000 sf to calculate employee ADT 3 Retail uses include shopping center, variety store, supermarket, gyms, pharmacy, etc. Acknowledgment: Other commercial uses may be subject to special consideration Sample calculations: Office: 20,450 sf 1. 20,450 sf / 1000 x 20 = 409 Employee ADT Retail: 9,334 sf 1. First 1,000 sf = 8 ADT 2. 9,334 sf -1,000 sf = 8,334 sf 3. 8,334 sf / 1,000 x 4.5 + 8 = 46 Em lo ee ADT I acknowledge that the plans submitted may be subject to the City of Cartsbad's Transportation Demand Management Ordinance. I agree to be contacted should my permit require a TOM plan and understand that an approved TOM plan is a condition of permit issuance. ,,f.?/#r-Jh.,..:,.L._._-----,. Applicant Signature: __________________ _ Date: 11/06/2020 Person other than Applicant to be contacted for TOM compliance (if applicable): Name (Printed): __ J_a_n_e_t_P_u_ll_e_n ,_A_r_m....:y'-an_d_N_a_v:....y_A_c_a_d_em---=-y ___ _ Phone Number: 760-54 7-5269 Email Address: JPullen@armyandnavyacademy.org Updated 8/1 5/2019 6