Loading...
HomeMy WebLinkAboutDWG 367-1L; PD 490; Carlsbad Research Center Lot 65; 01-09RECLAIMED WATER NOTES I. ALL WOf<I< &I-IALL ElE DONE IN ACCORDANCE WIT!-1 Tl-IE CARL&6AD MUNICIPAL WATER DISTRICT'& 'CARL56AD RECLAMATION !ii!.ILE5 AND REOOLATION& FOR GONST!ii!.ICTION OF RECLAIMED WATER MAIN&' DATED OCTOBER, l~'il3. 2. DRINKING FOUNTAINS SJ.,!ALL SE PROTECTED FROM SPRAY OF RECLAIMED WATER SE&T MANAGEMENT PRACTICES 5!-IALL BE USED TO MINIMIZE RECLAIMED WATER ENCROACI-IMENT ON f'UEILIC FACILITIES &UC!-1 A& PICNIC TABLE&, S6Q'S, PLAYGROUND&, &AND TOT LOT&, ETC. 3. BE&T MANAGEMENT PRACTICES &I-IALL BE USED TO ELIMINATE OR CONTROL To Tl-IE BEST EXTENT PO&&ISLE, PONDING, RUN-OFF, OYER SPRAY AND MISTING. 4. 1-105E Ell65 ARE STRICTLY PROI-IISITED. !:>. ON SITE CR055-CONNECTION& ElETWEEN RECLAll'"'EP WATER LNE:5 AND POTAl'JLE WATER LINES ARE 5TRICTL Y PROI-IIEllTED. 6. NO 6U6$TITUTION OF PIPE MATERIALS WILL ElE ALLOWED WITI-IOUT PRIOR AFF!<OYAL OF Tl-IE CARLSBAD MUNICIPAL WATER DISTRICT. 7. ALL ON 61TE MAINLINE PIPE5 &i-lALL J.,!AYE WAl<NING TAPE PER CARL5BAD MUNICIPAL WATER Dl5T!<ICT'5 !ii!.ILES AND REOOLATION5. ,I: 8. TI-IE IRRIGATION SYSTEMS 51-iALL ElE RliN ElETWEEN Tl-IE I-IOUf<& OF 10,00 PM AND 6,00 AM. Tl-IE FOLLOWING MOl<NING /SPOT IRRIGATION COJLD SE DONE AT A Dli=!=ERENT TIME! WIT!-1 QUALIFIED SUPERVISION PERSONNEL ON SITE. 'a. PROVIDE A MINIMUM OF AT LEAST Ill INCI-IE6 OF COVER OYER ALL WIRING AND PIPING. 10. NON-DESIGNATED USE AREAS &I-IALL ElE i"l'!OTECTED !=RCM CG,IT ACT WITf-1 RECLAIMED WATER. i!.14ETI-IER BY WINDBLOWN &PRAY OR SY DIRECT APPLICATION Tf-lROIJGI-I IRRGATION OR OTI-IER USE. LACK OF PROTECTION, IU-IETI-IER ElY DESIGN OR 5Y5TEM OPERATION, 15 5TRICTL Y PROI-IIBITED. 11. IRRK:iATION I-IEAD& &I-IALL ElE RELOCATED OR ADJUSTED TO Fl'<EvENT OVEf<&PRAYING ON 51DEWALK&, STREETS AND NON-DESIGNATED USE AREA&_ i,, RECLAIMED WATER QUICK COJFLING VALVES &I-IALL ElE OF TYPE DESIGNED FOR Tl-IE U5E ON RECLAIMED WATER DISTRIBUTION SYSTEMS /&FIKES NOT INTERCI-IANGEABLE WITf-1 PORTABLE WATER QUICK COUPLER 6PIKE6J PER CARL5BAD MUNICIPAL WATER DIST!<ICT Fii!JLE5 AND REGULATION&. 13. METER 51-!ALL BE SIZED SY Tel£ CARL56AD i"tJNICIPAL WATER DISTRICT. 14. ALL IRRIGATION PIPES 61-lALL BE STENCILED WIT!-1 Tl-IE WAl<NING 'NON POTABLE WATER' OR 'RECLAIMED WATER', COLOR COOED /PURPLE! AND LAID WIT!-1 WARNING TAPE PER CARL56AD MUNICIPAL WATER DISTRICT'& RULES AND REGULATIONS. I!:>. ALL POTABLE AND RECLAIMED WATER PIPES 5!-IALL eE INSTALLED Wlrn Tf-!E 5TENCLING ORIENTED TOWARDS Tl-IE TOP OF Tl-IE TRENCI-I. 16. WI-IEN A POTAElLE WATER LINE AND RECLAIMED WATER LINE CROSS, Tl-IE RECLAIMED LINE 5!-IALL SE INSTALLED WITI-IIN A PROTECTIVE SLEEVE. 1l-lE SLEEVE &I-IALL EXTEND 10 FEET FROM EACf-1 SIDE, FROM Tl-IE ClcNTER LINE OF POTABLE LINE, FOR A TOTAL OF 20 FEET. 17. A 10 FOoT i-lORIZONTAL SEPARATION BETWEEN POTASLE WATER AND RE'CLAIMED WATER MAINS MUST ElE MAINTAINED AT ALL TIMES. Tl-IE POTABLE LINE MUST 6!: INSTALLED ABOVE Tl-IE RECLAIMED LINE. 18. A MINIMJM OF 12 INCI-IES OF VERTICAL SEFARATION BETWEEN UTILITIES MUST 6!: MAINTAINED AT ALL TIMES. ,I: I~ DEVELOPER/CONTRACTORS &I-IALL CONDUCT A CROSS CONNECTION TEST AND COYER.AGE TEST AS DIR!:CT!:D ElY CARL&eAD MUNICIPAL WATER DISTRICT ENGINEER OR Tl-IE SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL I-IEALTI-I PRIOR TO ANY USE OF RECLAIMED WATER 20. QUICK COUPLIN6 VAL VE5 USED IN RECLAIMED WATER SYSTEMS &f-lALL CONFOl\!1 TO Tl-IE FOLLOWING. RECLAIMED WATER -QUICK COUFLING VALVES USED IN RECLAIMED WATER &I-IALL I-IAVE ACME TYPE TI-IRE'AD5 AND PURPLE COLOR!:P LOCKING COVERS PEisl"IANENTLY ATTACI-IEP TO Tl-IE VALVE. QUICK COJFLING VALVES 51-lALL 6E NELSON NO. 164&, I-IUNTER NO. I-IVIOOA-RL-NF OR APPROVED EQUAL. 21. AN ANNUAL CROSS CONNECTION INSPECTION &I-IALL BE DONE BY EITI-IER CARL56AD MUNICIPAL WATER DISTRICT OR SAN DIEGO COUNTY DEPARTMENT OF i:NVIRONM!:NTAL I-IEAL Tl-I. COPIES OF INSPECITON REFORTS WILL ElE FORWARDED TO Tl-IE NON-INSPECTING PARTY. * 22. PROVIDE RECLAIMED WATER 'DO NOT DRINK' 51GN5 AT LOCATIONS &I-IOWN ON FLANS ,I< 23. AN ON SITE USER/5UPEl'<VISOR &I-IALL ElE DESIGNAT!:D IN WRITING. Tf-1I5 INDIVIDUAL 5!-IALL ElE FAMILIAR WIT!-1 FLUMSING SYSTEMS WITI-IIN Tl-IE PROPERTY, WITH THE BASIC CONCEPTS OF BACKFLOW/CROSS CONNECTION PROTECTION. Tl-IE i<!=CLAIMED PURvEYOR'5 RULE5 AND REGULATIONS, AND Tl-IE 5PECIFIC REQUIREMENTS OF A RECLAIMED WATER SYSTEM, GOPIE& OF Tl-IE DESIGNATION, WIT!-1 CONT ACT PI-IONE NUMBERS 5!-IALL ElE PROVIDED TO CARLSBAD MUNICIPAL WATER DISTRICT AND SAN DIEOO COUNTY DEFARTMENT OF i:NvlRONMENT AL i--lEAL Ti-I. IN CA&E OF EMER6ENCY CONTACT __ Jlc_TT_~~--AT NAME OR AFTER f-lOUR5 CONT ACT JicTT AT NAME o, l'lJ&b .'1620 ~ 6l'l.1&6.'l620 ~ ,I: ITEMS N0.5 a, 19, ' 23 51-lALL 6E REQUIRED JUST PRIOR TO Tl-IE ACTUAL US!: OF RE'CLAIMED WATER ITEM NO. 22, Tel£ Slc;NAGE FLAN, 5!-IALL ElE A FART OF Ti-115 I.F. BUT Tl-IE ACTUAL SIGNS AND TAGS WILL 6E INSTALL!:D JUST PRIOR TO ACTUAL USE OF RE'CLAIMED WATER 24. 5!-IOW ALL FUeLIC AND PRIVATE POTABLE WATER MAINS ON TI-IE PLANS. 2S. ON RECLAIMED WATER SYSTEMS, ALL APPURTENANCES !SFRINKLER I-IEAD5, VALVE BOXES, ETCJ 51-lALL ElE COLOR CODED PURPLE PER AWWA GUIDUINE5 AND SECTION 404~!>4 OF Tl-IE CAL 1FORN IA I-IEAL Tl-I AND SAFETY CODE. TYPICAL SIGNS 6LACKLOOO ~-AJRPLE BACKGROUND I' BLACK LETTERS 36' /NT&J RE /SIZE:! 12' x 36' !M,rl) Ae& PLASTIC OR STICK ON VINAL &IGNS ALSO .eil6 ALUMINUM LAIMED WATER I' 6LACK LETTEf<& 2' SLACK L.ETTEFlS 12' /NTSJ LANDSCAPE EROSION CONTROL PLANS RECLAIMED WATER SYSTEM (PRIVATE) LOT 65 CARLSBAD RESEARCH CENTER CARLSBAD, CALIFORNIA SIGNAGE NOTES Tf-lE FOLLOUJINc:. GUIDELINES FOR Ti-IE USE OF RECLAIMED WATER ARE TO ElE PEl<HAN!:NTL Y POSTED INSIDE: Tl-IE DOOR OF EACH CCl',/TROLLER Wf-lERE TI-IEY ARE EA&IL Y Vl&leLE. PLACE ON 6-1!1 'xii' SIZED SIGN. COLOR, PURPLE BACKG.ROUNO WITI-I BLACK LETTERIN6. I. GUIDELINE& FOR RECLAIM!:D WATER USE I. IRRIGATE SETWEEN Tel£ f-lOUR5 OF lel,00 A"1 AND 6,00 AM ONLY, WATERING OUTSIDE Ti-115 TIME FRAME MUST BE DONE MANUALLY WIT!-1 QUALIFIED 5UPERYl50RY FEl'<5CNNEL ON SITE. NO 5Y5TEM &f-lALL AT ANY TIME BE LEFT UNATTENDED DURING USE OUTSIDE Tl-IE NORMAL 5CI-IEDUL!:. 2. IRl';IGATE IN A MANNER TI-IAT WILL MINIMIZE RliN OFF, FOOLING, ANO PONDING. Tl-IE APPLICATION RATE &I-IALL NOT EXCEED Tl-IE INFILTRATION RATE OF Tl-IE SOIL. Tn-1ER5 MUST ElE ADJUSTED 50 A& TO ElE COMPATl6LE WITI-I Tl-IE LOWEST SOIL INFILTRATION RATE FRE5!:NT. Ti-115 FROC!:!:DURE' MAY ElE FACILITATED ElY Tl-Ii" EFFICIENT SCI-IEDULING OF Tl-IE ALITOMATIC CONTROL CLOCKS, / I.E. EMFLOYING Tl-IE REPEAT FUNCTION TO BREAK UP Tl-IE TOT AL IRRIGATION TIME INTO CYCLES TI-IAT WILL PROMOTE MAXIMLN SOIL A650RFTION!. 3. ADJUST 5FRAY f-lEAOS TO ELIMINATE OVER5ffiAY ONTO AREA& NOT UNDER Tl-IE CONTROL OF Tl-IE CUSTC11ER i'OR EXAMPLE. POOL DECKS, PRIVATE PATIOS AND LOTS, AND STI\!Ei:TS AND SIDEWALK&. 4. MONITOR AND MAINTAIN Tl-IE 5Y5TEM TO MINIMIZE EQUIPMENT AND MATERIAL FAILURE. eROKEN SPRINKLER I-IEAD5, LEAKS, UNRELIABLE VALVE5, ETC. 5!-IOULD ElE REPAIRED A& SOON A5 TI-IEY BECOME APPARENT. S. !:DUCA TE ALL MAINT!:NANC!: PER&ONN!:L ON A CONTINUOUS BA5IS OR Tl-IE PRE5ENCE OF RECLAIMED WATER PER5CNNEL MU5T ElE INFORMED THAT RC WATER 15 MEANT FOR IRRI. PURPOSES ONLY, AND 15 NOT AF'f'ROVED i'OR DRINKING RJRPOSES, I-IAND, TOOL, WA&f-llNG, ETC. GIVEN Tel£ HIGH TUl<NOVER RATE OF EMFLOTEES IN Tl-IE LAND5CAFING INDUSTRY, IT 15 IMFORT ANT TI-IIS INFOR- MATION ElE DISSEMINATED ON AN ALM05T DAILY 6A5I5. IT 15 YOU, Tl-IE LANDSCAPE CONTRACTOR, WI-IO 15 RE6PON51BLE FOR EDUCATING EAC!j AND EVERY ONE OF YOUR EMPLOYEES. 6. oeTAIN PRIOR APPROVAL OF ALL FRCF05ED Ci-lANGE5 AND MODIFICATIONS TO ANY PRIVATE ON SITE FACILITIE5, SUC!-1 CI-IANGE5 MUST ElE 5U6MITTED TO AND APPROVED er Tl-IE Dl5TRICT EN5INE!:RING OFFICE: AND DE5IGN!:D IN ACCORDANCE WITf-1 DISTRICT 5TANDARD5. 7 ALL RECLAIMED WATER SPRINKLER CONTROL VALVE& 5!-IALL SE TAGG!:D WITI-I IDENTIFICATION TAGS. A. TAG& &f-lALL 6E u.!:ATf-lERFROOF FLA&TIC 3'x4' AJRFLE IN COLOR WITH Tf-lE U.ORD5 'WARNING RECLAIMED WATER- PO NOT DRINK' IMPRINTED ON ONE SIPE, AND 'Avl&O- AGUA IMFURA-NO TOMAR' ON Tl-IE OTI-IER SIPE. IMPRINTING 5!-IALL ElE PERMANENT AND BLACK IN COLOR USE TAGS AS MANUFACTURED ElY T. CI-IRl5TY i:NTERPRl5ES OR APPROVED EQUAL e. ON!: T A6 SI-IALL Eli: A TT ACI-IED TO EAC!-1 VAL VE A5 FOLLOU.l5, I. ATTACf-1 TO VALVE 5TEM OIR!:CTLY OR WITI-I PLA5TIC TIE WRAP OR 2. ATT AC!-1 TO SOL!:NOID WIRE DIRECTLY OR WIT!-1 PLASTIC TIE WRAF OR 3. ATT Aef-1 TO v AL YE COYER WIT!-1 EX16TING v AL VE COYER BOLT. ll. ALL SPRINKLER I-IEAD5 &I-IALL eE IND!:NTR"IED AS RECLAIMED WATER !lPRINKLER I-IEAD!l. II. EACf-1 AUTOMATIC CONTOLLER AND ITS ASSOCIATED EQUIPEMENT Sf-lALL BE IDENTIFIED WIT!-1 A SIGN BEARING Tl-IE WORD& 'i<l=CLAIMED WATER USED FOR IRRIGATION' IN ENGLIS!-1 AND 5PANISI-I, UJIT!-1 ElLACK LETTE"5 I' HIGJ.,l ON A PURPLE ElACl<:GROUND. Tl-IE SIGN &f-lALL ElE PLACED 50 THAT IT CAN BE READILY 6EEN BY ANY OPERATIONS PERSONNEL USING Tl-IE EQUIFEMENT. ,-1-• ___ 1_e·_rN_T_&1 __ ~1 W~ FECLAlvED WATER 00 !',OT [l'N( AVBJ -/>GJA MPURA "° TOAAR (5IZE! 16' x 16' 18' /NT5) APPFOVill cpl._' 8'dliiEERNG Pl.MK:HECKER INSPECTION PROCEDURES I CITY CONSTRUCTION INSPECTION Si-lALL INCLUDE, A. LOCATION OF FIF'i: LIN!:S S. TRENC!-1 PEl"Ti-1 C. REQUIRED SEPARATION !I-IORTIZONALL Y AND VERTICALLY! D. PIPE IDENTIFICATION. /F.O.G'S) POINT OF CONNECTION& !:. LOCATION AND IDENTR"ICATION OP SPRINKLER I-IEADS F. WARNING SIGN& AT Tl-IE SITE ANO ON Tel£ TRUCKS HAULING R!:CLAIMED WATER /IF RECLAIMED WATER IS USED FOR CONSTRUCTION! AN AFF!<OYAL LETTER REGARDING Tl-IE IN6PECTION OF Tl-IE FROJ!:CT 5!-IALL ElE OSTAIN!:D FROM Tl-IE CITY AND DISTRICT, AND eE FORWARDED TO Tl-IE COUNTY DEPAR'Tl1ENT OF ENVIRONMENTAL I-IEAL rn PRIOR TO FINAL IN!lPECTION AFPROvAL. II. Pl5TRICT FINAL IN6PECTION &I-IALL INCLUDE, A COVERAGE TEST, AFTER COMPLETION OF Tl-IE 5PRINKLEfit 5YSTEM, TO DETERMINE Tl-IE ADEQUACY OF COVERAGE ON Tl-IE APPROVED USE AREA AND PROTECTION OF AREA& NOT APPROVED FOR RECIEVING RECLAIMED WATER. S. WARNli-.:i SIGN5 AND LASELS. C. QUICK COUPLli-.:i VALVE&. D. ALL ASPECTS OF Tl-IE IRRIGATION, CONDITIONS INCLUDING WIND6LOWN SPRAY RUNOFF, AND FONDING. E. REQUIRED PROTECTION OF ALL RESIDENTIAL AREAS. F. REQUIRED PROTECTION OF IIELL&, STREAM&, RESERVOIR&, ETC, G. CROSS CON'-IECTION. Ill. ANNUAL INSPECTION 5!-IALL INCLIJPE, A COMFL!:TE INSPECTION IU-IIC!-1 5!-IOULD COVER FART A, FART 6 AND PART G OF Tl-IE 0I5TRICT'5 FINAL INSPECTION. KEY MAP LEC:.IEND, AF<EA OF FfWFOSEp f<ECLAIMED WATER USE Af<EA OF EXIST!~ RECLAIMED WATER USE SITE FARA□Av AVE;. 12 NO!ml r.ECUIMED WATERMAIII )ITS I POTAlll.E UIA'IER M!liN • l:EVEl.O"ER'S NAME-----=RO,=,--cY=-A"'=L~Y~l=LL=cAc:iEcc=~LL_C ______ _ FO E3OX 9b 72 AOCffSS:---~~-----------=------RANCl-lO SANT A FE CA 92@61 ™E Xk/j' · :p;ib · 1bW £116 ALUMINlN, .060 ABS PLASTIC OR !lTICK-ON VINAL SIGN!! REVISCNS MUJT BE M1"FOVED BY FI..IBLC HEAL ll-1 BIGNEEP, ASST, Pl.ANNING Dl£GTCA & DlsrnCT EI\Qr-EER PRffi TO IMPLEMETNA mN N RElD, DATE PLAN PREPARED 28 MAR 98 BY: SM. Af-!LE5 CAR...SBAD MUNICIPAL WATER OSTRCT DISTRICT APPR:JVED CHANGES BENCH MARK ,,.w_A, . 7', 1?4-, ••. h.- Vv1LUAM c PLUNTv!ER DATE NO. 08:CRF'TO'I APPFOVED DATE CEOCAIF'TO'I DISTRCT EI\GINEER RC£ 28176 SAN OEGO COJNlY DEPARTMENT OF LOCAmN __ ENVl~ENTAL HEAL TH (R.{.#IILJ.,,....,. 4 re. - Am'OliBJSY, DATE FECCffi FFOM _______________ _ El.EVAmN ________ DA1UM ______ _ DRAWING INDEX SHEET • I 2 3 4 5 b 1 8 ':l CONTENTS TITLE SHEET, PROJECT INFORMATION PLANTING PLAN PLANTING PLAN, LEGEND PLANTING PLAN, NOTES IRRIGATION PLAN IRRIGATION PLAN, LEGEND IRRIGATION PLAN, NOTES PLANTING DETAILS AND SPECIFICATIONS IRRIGATION DETAILS AND SPECIFICATIONo DECLARATION OF RESPONSIBLE CHARGE I I-IEREBY DECLARE H4AT I AM LAND5CAPE ARCI-IITECT OF Tl-IE U.OisK FOR Ti-1I5 PROJECT, THAT I I-IAvE EXERCISED RE5FON51ElLE CI-IAR::,E OYER Tl-IE DESIGN OF Ti-1I5 PROJECT AS DEFINED IN SECTION 6703 OF Tl-IE ElUSINE55 PR.Of'E5510N5 COPE AND Tl-IE DESIGN 15 CONSISTENT WIT!-1 CURRENT STANDARDS. I UNDERSTAND TI-IAT Tl-IE Ci-lECK OF PROJ!:CT DRAWINGS AND SPECIFICATIONS SY Tl-IE CITY OF CARL56AD AND Tl-IE SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL f-lEAL Tl-I 15 cONFINED TO A REVIEW ONLY AND DOES NOT RELIEVE Mi:, AS LANDSCAPE ARCI-IITECT OF WORK OF MY RE&PON61SILITIE6 FOR PROJECT Di:SIGN. THESE PLANS I-IAVE BEEN Fl'<EPARED IN &U65TAINTIAL CONFORMANCE WITI-I Tl-IE APPROVED LANDSCAPE CONCEPT FLAN, WATER CON5E1'VATION PLAN. FIRE !IUFFRESSION PLAN, AND ALL CONDITIONS OF APPROVAL RELATED TO LANDSCAPING. STE VEN M. AHLE&, LAND5CAPE ARCI-IITECT Fli.!'1 5 TE VEN M. AHLE& LANDSCAPE ARCI-IITECT P.O. eox 662, CARDIFf, CA ~007 URE LICENSE NO. 2SMAR98 DATE 16elb321'2U Pf.lONE SHE.ET 4.7 -jof--------- ,~.;c.« .. Mrr"m .,..,. ' Cc) C") (( ) c ) I c I I . . I ' Steven M Ahles LANDSCAPE ARCl-llTECT P.O. Box 682 Cardiff, California 92007 CM2.S38 ,......., Cl) z <( _J Q_ I-z w ~ w > 0 a: Q_ ~ w Q_ <( 0 Cl) 0 z <( _J SET ISSUED ™1.632.0288 fllxldlla 7606l1WM rr: w I-z w 0 <( I-oz rr: rr: <t:o Wu_ C/) _J w<t: rr:O L.000 CD-<-< a] a] (/) Cl) I--_J _J 0 rr: a: <{ <{ _JO 0 10 MAY 98 SHEET REVISIONS DATE PLAN CHECK 15 JUI. 98 PLAN CHECK 2 12 AUG 98 -,-1 ,_ DRAWN BY sma raJJ ·---......... ~ , ,' APPROVED FOR PLANTING AND IRRIGA TIQ'\J ONLY, INCLUDING PFECISE LOCATkJN OF PLANTING AREAS. TTTLE REVIEWED BY: INSPECToR CHECKED BY; PROJECT NO: 5812 SHEET TITLE: SCALE SHC:ET NO: L-1 OF "AS BUILr DATE DATE 1----+-----+----------+-----+-~---------lf----------, I S,EIET: 11 CITY OF CARLSBAD 11 S,E~ I . PLANNING DEP AAlMENT . " ~------------~ I---+---+------·-"" ""·-----------+---+------1-----t----< LANDSCAPE TITLE Sl-lEET LOT 65 C~56AD RESEAA0-1 CENTER CM.IUD. J06 NO. 98-216 I I I I I 1- I I I I I I I I I I I I I I I I I I I I 0 <Cf 0 ff'. z 0 1- (j) '{ INTERSECTION SIGHT LINE KEY MAP la ~ TRAIN VINES ro GROW ON WA ~-EUCALYPTUS TO BE REMOVED ,,,--PROVIDE RWD HEADER AT PLANTER- TURF EDGE, TYPICAL T ,·,:, :,, ----,-....I..,.~· EXISTI~ PAr.KWAY LANDSCAPE HAINT AIN, REPLACE ANY DISTURBED PLANT HAIN+ENANCE BY ASSOCIATION T PROVIDE RWD HEADER AT PLANTER-_ ______, RH TURF EDGE, TYPICAL , , \ •.. ~,··/ .... ··i~ / .. ..--r--& .. COLLEGE BL VD PLANTING PLAN NORTI--I 20 40 Fl 1 rlllllll\111\111\11111 1 l 11111111111111111111111111111111!1111111111111111111111111111111111 SCALE SEE SHEET 3 FOR PLANTING LEGEND PAVED ACCE55 DRIVE \ [l ' IHI ,......,.. "' .. ,.,. OPEN CELLS NEAR TOP OF WALL PLANT PER LEGEND, SHEE"• L-3 , @. ·. 1\ ~@ ~ , 'I @m@!)i .. ,~ ~· ,,· \ '·, \; ~1 ~'l!'m . APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS, :,--------,,-' .............,. I I I BUI I w- 31 I-"st- ' _j ~I ,- l-U ill :r <S) ill ~- l-U <S) I ' - REVIEWED BY; INSPECTOR Steven M Ahles LANDSCAPE ARCHITECT P.O. Box 682 Cardiff, Califomia 92007 CA. 25'l8 760,632.0288 w, 441 tax/data. 760..632.0289 CJ) z <( er: _J w Q_ f- f-z z w w () <( ~ ::r::-w uz > er: er: 0 <(o er: WLL Q_ (f) _J ~ w<( er: 0 w LOO 0 o_ <( c.o <( <( 0 mm CJ) r-~ ~ 0 z 0 0: 0: <( <( <( _J _JOO SI I ISSUED SHEET REVISONS PLAN CHf:·s PLAN CHH.0 • DAIE , ,UI JS /\LI:, -JH WALL, S PFRIM I -~-?OCT rn : ·1 NCV 91', DRAWN BY CHECKED BY PR'.JJECT 1\0 '3812 81--EET TITLE S/IITNO.: L-2 UI "AS BUILr OATE r---,----,--------__l_----,---,--r-~----r;====::;-;=====;:====;:::::;=======-·-· . .. ___ , ___ ___, l---l-----1-------------+------t----t-----t------i I S,2EET I CITY OF CARLSBAD. I l~E:ra I DATE • u,aM••-••••"'" •---+ -------- I---+---+---.. ,,_, ,. , DA TE !NITTAL LAND.ARCH. RIEVISION DESCRIPTION DATE INITTAL DATE lf\lllAL CITY APPROVAL OTHER APPAOVAL PLANNING DEPARTMENT . _j _ PLANTING PLAN FOR: LOT fi& CARLSBAD F£&EA~ CENTER OWN BY, __ PROJECT No., CHKD BY, FIELD BK, PD 4 9'21 CJ"IJIJD. JOB NO. 98-21fi " i""'" I I I I EXISTING PARKWAY TURF AND STREET TREES MAINTAIN, REPLACE ANY DISTURBED AREA OR PLANT MAINTENANCE BY ASSOCIATION ~------- ~ --.c EXISTING TREES IN AREA OF GRADING -----=-~c--1 SHALL BE TRANSPLANTED TO NEW GRADE AT EXISTING LOCATION H KEY MAP ~ ~~ ~ RH l !/ // 1/ 1/ 1/ PROVIDE RWD HEADER AT PLANTER· _ __j"" TURF EDGE, TYPICAL BUILDING: ill 2'3,336 SF rUTUR~ FF 278.2 / .•· / ---..,_I ·, \ j ..____, ~ H I I I I ~-,-.;~.~_.k.l-- , ,, ,•· ,) ·' ,,/ ! ' ~-, _;'i,?,), ··/•.j .. ·/C . \2< ,;r ---..,_ I ---{.... $ \ /1 \..~ .. ··I .A/4 ~~ J . ' ' ' ·" ,,' .. '<,~ I,.·· ;/>J .z... ,j PLANTING PLAN NORT!-l 20 40 Fl ~ 1'11111111111111111111111 j 11111111111111111111111 .... _111111111111111mm11l111111111111111111111m SCALE i I I I ' I I I I I I I SEE SHEET 3 FOR PLANTING LEGEND I PLANT LEGEND SrMBO/. tJOT 4NIC:AL NAME GCJ1MCNNAME SIZE =r1rr Steven M Ahles LANDSCAPE ARCHITECT ...---....TREES P.O. Box 682 Cardiff, California 92007 SEE SHEET L 4 MATC E EXISTJN5 TREES ULHU5 PARVIFOLI A PINU5 CANARIEN515 PLAT ANUS ACEJ.l=OLIA EVERGREEN FEAR CANARY ISLAND FINE PLANE TREE AffROX!MATE L!XATI/Jf/S SilO//N, TREES TO REMAIN /MESS Lc,;;ATEV IN NE//! ORIJ,f f'ROFOSE[) TREES F<ECA5T~H FaiANIZOfflUH ,___......._ ACARANDRA ACUTIFOLIA F OSFORMUH UNDULA TUM 15TANIA Cor-FERTA TRl5TANIA Cor-FERTA QUEEN PALM JACARANDRA VICTORIAN BOX BRISBANE BOX BRISBANE BOX B BTi-1 42 24' BOX 29 IS GALLON 29 24' BOX I~ l!:i C.ALLON 12 ABELIA 'ED GOUCHER' ABELIA 5 GALLON 5Hl<1JB5 © le) LINE o AGAFAN,HU5 AFRICANU5 LIL r OF NILE ! GALLON BEGONIA RIC!jMONDEN515 BEGONIA I GALLON 81/) 222 ~ 32 33 34 6 32 31 43 31& 226 IIZ'3 63 0Y0 0 ® @ © 0 CD G) 0 VINES Cl5TU5 PURPUREU5 ROCKROSE i GALLON COLEQ\IEMA PULCl-llsl.lM PINK BREATH Cf HEAVEN 5 GALLON COTONEASTER LACTEU5 CLUSTER ElERRY 5 C.ALLON E5CALLONIA fR5PE511 E5CALLONIA !:i GALLON HAI-IONIA LOMARI IFOLIA C.RAFE I-IOLL r 5 GALLON NERIUM 'LITTLE RED' DWAf.f OLEANDER 5 GALLON FHORIMUM 'AUTROFURFUREUM' NEW ZEALAND FLAX 5 GALLON FITTo&FOtst1Llt' 'VARiGATUH' VARIGATED HOCKORANGE 5 C.ALLON RHAPHIOLEP15 L 'ENCHANTRESS' INDIAN HAWTHOF:N 5 GALLON TRACHELO5FEJ.d1UH JA5MINIODIE5 STAR JASMINE 5 GALLON LIGl.15 TRU'1 JAPONICA FRlvEL 5 GALLON ~ FICU5 REFEN5 CREEPING FIG !:i GALLON D □ ' . FE5CUE 50D i EX15TING FELARGONIUM PELT A TUM IVY GERANIUM ;:LATS 12' O.C. HEDERA HELIX ENGLISI-I IVY FLATS 12' 0.C. OPEN CELL RETANING WALL PLANTING, D D FICUS REPENS CREEPING FIG FLA T5 2 FER PLANTING CELL APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. TrTI.E REVIEWED BY: INSPECTOR CAfma _ .. , (/) z :5 Q_ 1-z w '.2 w > 0 a: Q_ ~ w Q_ <( 0 (J) 0 z <( ___J S::T ISSULD 760.6320288 fuldata. 760.632.0289 a: w 1-z w o<C ::r::-oZ a: a: <Co WLL (J) _J w<C er: 0 LOoo CO <(<( mm (J) (J) I--___J ___J 0 0: a: <( <( _JO 0 10 VAY 98 S-IEET REVISIONS: DATE ------·---·· PLAN CHECK 15 JUL 98 PLAN CHECK 2 12 AUG 98 WALL, S PERM. 8 OCT 98 WALL, S PERM. 30 I\JOV 98 DPAWN BY: smc CHECKED BY: PROJf'CT NO SI lcFT TITLE SCAL:: SH::ET NO L-3 OF "AS BUILT" DATE --.-,.,•~•,m DATE ':1812 ===:==-=-~----_··_·······_-··_· ·_·· -------+---+-----+==~~~-= I S73EETc I ~-C-ITY __ o_F_C_A_R_L_S_B_A_D~ I ~E~ I , PLANNING DEPARTME'NT " DATE l'llmAL LAND. ARCH. REVISION DESCRIPTION DATE INITlAL DATE INmAL CITY APl'ROl'AL 01HER APPROVAL PLANTING PLAN FOR, LOT 65 CAFa.5ElAD RESEA~ CENTER CMJUD. J06 NO. 98-216 SHEET ; I I I I 7-----r,~ / . i • ,· , 1<'.:>::/'" o,,, • .,,.., BUILDING II 33,5'33 SF I I I KEY MAP la NORTH NT$ .,.........,... ~ -. -. ..,..........,. '\ :'"" /~~----" ',: · ->-". ': ·,' >,) : ,:_;;-_:: ·::_:0::1.:-:;:;,J.' ,:v:· ':)t::·',:/ :,: } ,'•:,:: ,'.///."•'':,) , ,·~ OPEN CELL RETAINING WALL SEE LEGEND, 5!-lEET L-3, FOR PLANTING H I t 1/ j I , 1/ I 1/ I 1/ ! 1/ 1/ if . . I I BUILD ING III 2'3,330 SF FUTURE i i I ! --1, . I (! I CITY SLOPE PLANTING NOTES 5LOPE5 OVERS FT. IN VERTICAL I-IEIC.I-IT SI-IALL MEET: A) 5T ANDARP "I -COYER CROP/JUTE MESH (1@12'% COvERAGEJ BJ STANDARD "2 -GROUND COVER, MINl1"1UM FLATTED SIZE (I@@% COVERAGE! C) STANDARD #3 -LOW SPREADING SHRUBS FROM MINIMUM 2-3/4 IN. LINES rll2l% COVERAGE! DJ STANDARD •4 --F<EES ANP 51-!RUBS FROM MINIMUM I GALLON (1/200 5.R.! PLANTING PLAN NORTf-i 20 40 Fl I f 11111111111111111111111 j 1111111mmm11111m""'-1111111111111111111111111l11111111111111111111111 SCALE I j I I ' i I ' I I I I I ' ' I ' I I I ' ! I I JAi I I I X~·· X ,' ,' ,/ , · ... x~/# . i ,' , .. ·····< '#' \~ ··" I • • · u, MATCH LINE -,."""'f-'<f<......' · ..... , --• SEE 5!-lEET L-3 SLOPES BETWEEN 4 AND 8 FT. IN VERTICAL I-IEIGI-IT 51-!ALL I-IAVE STANDARD "I, "2, #3 A60VE SEE SHEET 6 FOR IRRIGATION LEGEND t----+----+--------··-··"•"""" 5LOPE5 3 FT. OR LESS IN VERTICAL I-IEIGI-IT AND ADJACENT TO PUBLIC WALKS OR STREETS !-!AVE STANDARD "I. PLANTING NOTES I. Ti..E PLANTING PLAN 15 PIAC:iRAMMANTIC ANP Si..ALL BE USEP AS A GUIDE FOR SETTING OUT PLANTS. PRIOR TO PLANTING, Ti..E LANDSCAPE ARCI-IITECT SI-IALL BE CONTACTED TO APPROVE ALL PLANT LOCATIONS AND DIRECT ADJUSTMENTS. 2. PLANT MATERIALS Si..ALL CONFO~ TO NUR5ER'r'MAN'5 STANDARDS FOR SIZE ANP !-!EAL Tl-I ALL PLANTS ARE SUBJECT TO REJECTION BY Tl-IE LANDSCAPE ARCI-IITECT IF SUB5TANDARD IN 5IZE, QUALITY OR !-!EAL TH 3 PLANT COUNT5 ARE FOR Tl-IE CONVENIENCE OF CONTRACTOR ONLY. CONTRACTOR 15 RE5FON51BLE FOR ALL PLANTS 51-!0WN ON FLAN. 4. IRRIGATION 5Y5TEM 51-!ALL BE FULLY OPERATIONAL AND ALL PLANTING AREAS TI-IOROUGI-IL Y SOAKED PRIOR TO PLANTING. S. LANDSCAPE CONTRACTOR S!-lALL MAINTAIN A MINIMUM OF 2% DRAINAC:IE AUJAY FROM ALL BUILDINGS ANP FINIS+-! GRAPES SMOOTI-IED TO ELIMINATE PUDDLING OR STANDING UJATER CONTRACTOR SI-IALL COORDINATE UJITI-I OTI-IER TRADES ANP MAINTAIN DRAiNAC:iE PURING CONSTRUCT ON. 6. REMOVE ALL EXISTING VEGETATION /EXCEPT INDIVIDUAL PLANTS TO REMAIN P::R PLAN AND AS IDENTIFIED BY LANDSCAPE ARCI-IITECT.) TRAS!-l, CLIPPINGS AND OTHER DEBRIS IN PLANTING AREAS. ERADICATE BERMlJDA GRASS AND NOXIOlJS WEEDS AS FOLLOWS, A. UPON INSTALLATION OF IRRIGATION SYSTEM, CUT WEEDS ANP APPLY AN ALL PlJRPOSE FERTILIZER, SUCI-I AS 2!;,/Zl LBS/AC OF 16-6-8 AND IRRIGATE FOR TWO TO FOUR WEEKS. B. Wl-lEN WEED5 AND GRASSES ARE APPROXIMATELY ONE TO TUJO INCl-lE5 IN HEIGHT, 5~Y WITH A NON SELECTIVE HER6ICIDE. C. PLANT AS SPECIFIED. l. PROVIDE A SO:L TEST OF CI-IEMICAL AND AGRICULTURAL ANALYSIS PRIOR TO APPL YING SOIL AMENDMENTS. ADJUST AMENDMENT SPECIFICATIONS TI-IEREAFTER PER LA.'S DIRECTION AND CITY REVIEW AND APPROVAL FOR BIDDING PURPOSES, ASSUME Tl-IE APPLICATION OF Tl-IE FOLLOWING AMENDMENTS AND FINIS!-! GRADING, IS/Zl LB5J!/Zl01Zl SF AGRICULTURAL GYPSUM 25 L65Jl000 SF 12 -12-12 FERTILIZER IS0 LBSJl001Zl SF 'GROWPOWER PLUS W/ SULFER" FOR AREAS OF 3,1 SLOPE GRADIENT OR STEEPERc RAKE INTO TOP ONE INCi-i OF Tl-IE SOIL. FOR PLANTING AREAS LESS TI-IAN 3, I IN SLOPE, 3 CU. YDSJI@@@ SF NITROLIZED TOPSOIL MIX ROTOTILL IN Tl-IE TOP 6' OF SOIL THEREAFTER FOR ALL AREAS: RAKE AND FINE GRADE ALL PLANTING AREAS. MAINTAIN A MINIMUM 2% DRAINAGE AWAY FROM ALL 6UILDING5 AND STRUCTURES, AND 5% WITI-IIN FIVE FEET OF 6ULIDNG OR STRUCTURE. SMOOTH FINIS!-! GRADES TO ELIMINA-E PUDDLING AND STANDING WATER COORDINATE WIT!-! OTI-IER TRADES AND MAINTAIN DRAINAGE DURING CONSTRUCTION. APPLY SOIL LEACl-1ING AT LA'S DIRECTION AND CITY INSPECTOR APPROVAL S. VERIFY TREE PIT DRAINAGE WIT!-! 24 !-!OUR WATER FILL TEST PRIOR TO PLANTING. ALL BOXED TREES NOT DRAINING ARE TO 1-!AvE A 4' DIAMETER AUGER HOLE DRILLED THROUGH ANY I-IARDPAN OR COMPACTED EARTI-I AS REQUIRED TO PROVIDE DRAINAGE. '3. PLANTING PITS SHAL;_ BE TWICE Tl-IE CONTAINER WIDTI-I AND OF EQUAL PEPTI-I. I@. PLANTING FITS AND PLAN7ER5 SI-IALL 6E 6ACKFILLED PER SOIL TEST i'<ECOMMENDATIONS. FOR BIDDING, ASSUME SITE SOIL AND 1/3 (BY VOLUMEJ NITRFIED $OIL CONDITIONER MIX. II. TREES, SI-IRUB5 AND GROUNDCOVERS SI-IALL BE FERTILIZED AT TIME OF PLANTING! WITJ-l AC:iRIFO~ TABLET<S) PER SPECIFICATIONS TµE "OLLOWINGi RA TES, FLAT MATERIAL -I (5 GRAMJ TABLET LINERS -2 (5 GRAMJ TABLETS I GAL SIZE -I TABLET 15 GAL -6 TABLETS S GAL SIZE -3 TABLE~s 24' BOX -8 TABLETS 36' BOX SIZE -10 TA6LETS 48' BOX -12 TABLETS 12. DOUBLE ST AKE 15 GALLON AND 24' BOX TREES. CONTRACTOR SI-IALL BE RESPONSBLE FOR TREE 5TA6ILITY FOR Tl-IE LENGTI-I OF Tl-IE GUARANTEE 13. LOCATE STREET TREES 3 FEET b INCI-IES OUTSIDE RIC.I-IT OF WAY, EQUALLY SPACED AND IN ALIGNMENT WIT!-! TREE ON OPPOSITE SIDE OF STREET 14. CONTAINER PLANTS 51-!ALL NOT BE PLACED WITHIN 24" OF SPRINKLER !-!EADS. IS. POST PLANTING FERTILIZATION 51-!ALL BE PERFORMED BY CONTRACTOR AT 3@, AND '3@ DAY5 AFTER PLANTING. lb. SI-IRL!BS 4 TREES 51-!ALL BE UNDER PLANTED WIT!-! GROUNDCOVER OR I-IYPR05EED AS 51-!0WN BY ADJACENT 5'r'MBOL. 11. PROVIDE TI-IREE O') IN. DEPTI-I 'WALK ON BA~' MULCI-I IN ALL NON-TURF PLANTING AREA5 LESS TI-IAN 3:1 IN SLOPE. SUBMIT SAMPLE TO CITY INSPECTO FOR APPROVAL PRIOR TO BULK DELIVERY TO 5ITE. 18. MAINTAIN ALL PLANTINGS FOR NINETY ('312') DAYS AFTER COMPLETION. KEEF AL .. AREAS CLEAN, WATERED AND WEED-FREE. ALL DEAD OR DYING PLANTS SHALL BE REPLACED DURING THE MAINTENANCE PERIOD. 19. CONTRACTOR Sl-lALL. GUARANTEE PLANT LONGEVITY FOR ONE YEAR. APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. TITLE REVIEWED BY: Steven M Ahles LANDSCAPE ARCf.llTECT P.O. Box 682 Cardiff, California 92007 CMZ538 N\1# .. 1 Cl) z :5 0.. 1-z w ~ w > 0 a: 0.. ~ LLJ n_ <( 0 Cl) 0 z ::s SET ISSUED: 760.632.0288 fax/data 760.6320289 a: w 1-z w o<C ::r::-oZ a: 0: <Co WLL Cl) _J w<C a:O LOOO ,,-. <( <( ....-mm I-Cl) Cl) _J _J 0 0: 0: <( <( _JOO '0 MAY 98 SHEET REVISIONS DATE PLAN CHECK 15 JUL 98 PLAN CHECK 2 12 AUG 98 WALLS. ~ERM 8 OCT 98 WAIi .. S ~E:RIM 30 NOV 98 DRAWN BY ,ma CHECKED BY ~812 SHEET T'TLE: SriEET NC L-4 OF "AS BUILT" DATE --------··-- ....... ,. ', ...... ,,, __ , ______ , __ -----+---1-----+---l----l INSPECTOR PLANTING PLAN FOR: CHKDBY• LOT bS CAAL56AD RE5EAfia".l.l CENTER DATE SHEET DATE NTIAL RIE'VISKJN DESCRIPTION DATE NTlAL DATE NTIAL DWN BY1 --I PROJECT NO.: 11 DRAWING NO, RELD Bl(: -·-c..__P_D_4_9_0 _ ___, 36 7-IL LAND. ARCH. crrr APPROVAL OTHER APPROVAL CM.W.D. JOB NO. ~-216 I I I I I I I I I I I I I I .-\1--------1 I 1-1/4 I I I I I I POT ABLE LINE CRO55ING I 5LEEvE FER 5PEC ' \1 + I 11 31411 I n I I I I I!>' I I 11 I INTERSECTION 5IGf-lT LINE I KEY MAP E NOR™ ' I 1 ; a FRE56URI: LOS!i CALCULATIONS 5Y5TEl1 NO, SY5TEl1 c.FM, STATIC ffi:551.M:, METE!s ELEVATION, LATERAL 5Y6TEl15 FIFE FIF:: 'C' 6Ec;TION FACTO!s l 3 4 !i b , 8 ~ 'l'-l',£1-;<I ~'Gw ~ l!i0 l!i0 150 l!i0 l!i0 l!i0 ISl!I l!il!I l!il!I l!il!I IS0 8 32.~ 14b (!i!;l'J fJG!.! ll1 ~1FE TYPE CL 3l!i CL 315 CL 315 CL 200 CL lOO CL lOO CL lOO CL lOO CL loo CL lOO CL 200 FIFE 51ZE Ill Ill Ill 3/4 3/4 I I I 1-114 I-V4 2 NO. I OF I FIFE Aco.JM. PSI LENSrn GPH LOSS 15 12 1!1.11 15 3h l!).4 15 !i.4 1!)81 l!i 11 f>.41 15 ~.0 li>h5 15 l!i>B 11>21 15 ~1, 11>38 l!i 14.4 f>.41 15 IE,1 f>.l!i Iii> 180 li>.12 31!1 32.~ 11>211> -------·-------------- A. TOTAL LATEAAI. 5Y5TEl1 L0551:S FLe>ttJ I IE'FER GEE LE6END ~ I POINT OF CONNECTION I I IN. RECLAIMED WATER METER RE55URE, 125 P51 (550 f-lGL) RH .b_EVA~ON = I5B ~-~~. ~:__~ ......... . ..... . Ml!lCRLANEl"lJ5 L055E5 WATER METER I' 122 BAO<fLOUI f'lii:EVENTER I-In' S.0 MAINLINE FIFE TYF!' FIFE 51ZE PIF'E LENCMT GPH L055 ==============-===== CL 315 l' 1!il!I 32.4 t>.15 FITTll-r.;& GATE VALE Iii>% OF LATERALS !i>b c:om;vL VALVE I-In' i<EAD LOSS TO HICME&T i<EAD 4b FT• .433 NEIJ!.li.lBLE lb IS.S ----------------- 8. TOTAL Ml!lC. LOSSES C. TOTAL 5Y51EH L055E5 D. DESIGN OF'ElsATING FRE56U!sE ----------------E. ffi:56U!sE lsEQl.lllsED AT FDL. EXCESS !DEFICIT! msm - !ll3~ 11>3.& (SET ffi:551.llsE l<EOOLATER • ~Ii> f'SI! CONTROLLER-SEE LEGEND--) EXTERIOR WALL MOUNT CONNECT TO II0v POWER AT ADJACENT 'J' BOX * --ll-x--F- -------- • . • \ E Ill I I j I I I I ~--~-~~:::::~ I' 1-1/4 ,ti '·t>' .._, • 1n ·112~ \ I . -----~--+--------=--=------v-1! ,4-2.',c," ---~---'---~-~-=--=------.:..::__::___ -•r .,,,, t :jt' ) "-\·..,~ .,,, ------o------- 0..tf~\,,W5f- ~vcA"i'l"t7 ~1 I I I 1 I I ,: ,. : BUI( I 4!'3 ~ L:-l-w- 31 I-r- ' .....I ~I t- Ill Ill ::r: <I) I.U ~-ill I ' - l I i ,.s:, ' -.....I ... · I .. i I rp Steven M. Ahles LANDSCAPE ARC!-!ITECT P.O. Box 682 Cardiff, California 92007 CAt ll18 7606320288 NV• 441 fu/data 1f,Q6l201J19 Cf) z <( ....J a.. 1---z w '.2: w > 0 a: a.. ~ w a.. <( () Cf) 0 z <( ....J SET ISSUED: a: w 1---z w () <( I- ()z a: a: <(o wLL (J) ....J w<C a:U LOo o ,r. <( <( '--l,../ (0 (0 I-~~ 0 0: a: <( <( __J 00 10 MAY 98 SHEET REVISIONS: DATE PLAN CHECK 15 JUL 98 PLAN CHECK 2 12 AUG 98 WALL. S. PERIM 8 OCT 98 WALL. S. PEl,IM 30 NOV 98 DRAWN BV sma CHECKED BY: PFDECT NO, ':l812 SHE:FT TITLE: SCALE: COLLEGE BL VD EXISTING PAl-l<UJAY IRRIGATION SYSTi:;:EM;;--=:~~~~----~--~---.__--------------------....._ REPAIR AND REPLACE TO ORIGINAL CONDITION ~--------------~-- MAINTAIN A55OCIATION CONTROL IRRIGATION PLAN NORT~ 20 40 Fl I f 11111111m11111!11111I I rnm111111111111111111 "'"'"-~1111111111111111111111l11111111111111111m SCALE SEE SHEET 6 FOR IRRIGATION LEGEND - APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PFECISE LOCATION OF PLANTING AREAS. OF TfTLE REVIEWED BY, 1Ni~44<t-=----,--)O~ ,_-+----+------------=--=--=--=-===--+------I I SH~ET, I CITY OF CARLSBAD I SHEQETS I ;:; PLANNNG DEPARTMENT • ,----~--_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_----' ___ ~ ' DAlE INmAL LAND.ARCH REVISION DESCRIPTION DATE INITIAL INmAL CITY Af'PltOVAL DTI<ER APPROVAL IRRIGATION FLAN FOR, LOT b5 CARLSBAD RESEARCH CENTER PROJECT NO, PD 49~ CMJUD. J06 NO. 98-21'1 SHEET I I r'1f). -/4 //'' ,,.,[ '~ ··<·, " . r -~-.::....,;: ~ t I I i i I .... 1,, I ;, f 1-114 1-1/l ---- I EXI TING PARKWAY IRRIGATION SYSTEM W REPA~ AND REPLACE TO ORIGINAL CONDITION ~ i ~ ~=~~:~~:: _/ ffi-~ ~ I I I ... i ~ I <C -m ~ ~~ KEY MAP la NORTH NTS -- . . . .. I"- .. ' , r I ' -------.: --- - I " ~ .. :1/ i/ 1/ 1/ 1/ I I I I / BUILDING Ill 2'3,336 SF FUTURE FF 218.2 ' I ' I l / ' : ______ ,l _,___.-" ··' / _,_,., / i Ill _!/''...; I IRRIGATION PLAN I ~~--., ...... I = 1./ / I Q / --., ! I / I I I I I I / SEE Sl-li;:ET L-1 I --/1 '(2 I I § I I I I 21 \11 I 21.2 ~ _ _.,,,;:' (~ 20 40 FT. NORTl-l I r11111111111111111111111I ~ rn1111111111111111111JIWll-111111111111111111111111l,11111111111111111111 SCALE IRRIGATION LEGEND IF?RIG.ATION I-IEADS 5YMOOL HAKE HODE. NOZZLE F5I GFH R ARC DETAIL DESCRIPTION D, RAINBIRD I8I2-SAM li!lV AN-FC5-!!'2i!l 3i!l i!l2 7 ±4S F/L-9 FOF-LIF SFRAY RAINBIRD li!lQ • PC5 • i!l3i!l 3i!l i!lJ 7 9i!l FOF-LIF RAINBIRD li!ll-l-PC5-i!l4i!l 3i!l '1>.4 7 18'1> POP-LIF RANBIRD I'1>TQ -PC5-'1>6 '1> 3i!l '1>b 7 24'1> POP-UP ... RANBIRD I'1>F-PC5-'1>S'1> 3€! '1>.S 7 36'1> FOP-UP □ RAINBIRD I'1>VAN-PC5-'1>3'1> 3i!l '1)3 1'1> X FOF-LIF ' El RAINBIRD I'1>Q-PC5-'1>4'1> 3€! '1).4 1'1> 9'1) FOF-LIF / / I] RAINBIRD I'1>\-I-PC5-i!l6rli 3i!l !lib lrli I8rli FOF·UP 'I f -A /I I ~I \t ) / ["jJ RAINBIRD I0TQ-PC5-rli9i!l 3i!l i!l.S li!l 240 FOP-UP • RAINBIRD I'1>F-PC5-I25 3€! 12!; li!l 361!) FOF-UF 0 RAINBIRD I5VAN-PC5-06'1> 3€! '1>b 15 ±4c, POP-UP e RAINBIRD I5Q-PC5-i!l'="' 3€! i!l9 12 9i!l POP-UP ~ RAINBIRD l:'>H-FCS-11:'> 3i!l l.lS IS 181!) POP-LIF ~ RAINBIRD l:'>T-FC5-I2S 3€1 115 15 I2i!l FOF-UF 0 RAINBIRD I5TI-PC5-26i!l 3€1 2b IS 24i!l FOF-LIF • RAINBIRD l:f-PC5-37rli Yl! 3.7 IS 36i!l POP-UP ®l RAINBIRD l8i!l6-5AH 5Q-B Yl! rli5 5 9rli BUBB~ER ~ RAINBIRD 1 Sl-1-B Yl! Li!l 5 IW BUBBLER Ii) RAINBIRD SF-B 3€! 2ff) 5 36i!l BUBBLER 0 RAINBIRD 50-B-PC5-i!l3i!l 3i!l 1!)2 3(,'1) BUBBLER <D RAINBIRD I555T-PC5-i!l6rli 4 X 24 IBl!l FOP UP 3i!l i!lh © l-lUNTER FGH-i!li!l-3RV 2ff) lffJ 2i!l' 36'1) GIL-9 RISER 0 HUNTER FGH-I2-ARV lffJ lffJ 2i!l' ADJ. FIL-9 FOF-UF ® RAINBIRD 1600 l555T-PC5-i!J(,rli 3i!l '1>b 4 X 24 IBl!l GIL-9 RISER 0 HUNTER FGH-i!li!l·ARV lffJ lffJ 2i!l' ADJ. C,/L-9 RISER @ RAINBIRD I8I2-SAH 8Q-FC5-i!l2i!l 3i!l i!l2 5' 9i!l F/L-9 FOF-UF G) RAINBIRD I8I2-SAH 81-1-PC5-,N0 31!) i!l.4 5' 181!) l SPRAY CD RAINBIRD I8I2-SAM BTPCS-030 30 03 5' 120 SPRAY IF?RIGATION I-IEAD NOTES (D USE RA INBlf<P PC5 SCREEN i!l30 @ USE RAINBlf<P PCS SCREEN~ OTI-IEfi! EGIUIFMENT =S Y='1=B"=O=L=====M=,A=K="E=====M=O="'D="'E""'._.. 51 ZE DESCRIPTION PET AIL/5µEET IRRITROL MC PLUS ~ST A. W/RAINBIRD RAINCµECK FEBCO B25Y 1-1/2' WILKENS 510'1' 1-1/2' RAINEllRP FEB-PRS PER KEY I CONTROLLER ~-'A' Xl)<\ WALL MOUNT CONTROLLER AUTOMATIC RAIN sµur OFF BACKFLOW PREVENTER PRE5URE REGULATER CONTROL VALVE A/L-'3 B/L-S C/L·S X) 5 TA TION NUMBER VALVE SIZE VALVE GPM 'I I, 11 VALVE KEY ( F; CALSENSE FM·2 @ NELSON "lb45 2' I' FLOW METER QUICK COUPLER VAL VE II-ii KBI BTU SERIES LINE SIZE 'TRUE UNION' BALL VALVE --/PURPLE) CL 3IB 2·1/2' PVC PRESSURE MAINLINE __ /PURPLE) CL 200 scµ 40 SC!-l 80 PER PLAN PVC LATERAL 1/2 "ONLY PVC LATERAL 2X LINE PVC SLEEVE 2" PVC ELECTRICAL SLEEVE NOTE, 5LEEEVE DEPTl-lS PER SPECIFICATION NOTE, EXTEND ALL SLEEVES 12' BEYOND EDGE OF PAVING * RECLAIMED WATER SIGN SEE KEY MAP (Sl-!EET :..-1) SEE IRRIGATION NOTES AND DETAILS RECLAIMED WATER NOTES ALL IMPROVEMENTS PROVIDED WILL BE CONSTRUCTED FOR FUTURE RECLAIMED D/L-'3 E/L-'3 I 4J/L-S µ;L-S 1 WATER USE, AND SHALL COMPLY WITH ALL CITY OF CARLSBAD AND SAN DIEGO COUNTY DEPARTMEI\T OF ENVIRONMENTAL 1-lEALTl-l REGULATIONS. R!:CLAIMED WATER NOTES ON SHEET I AND DETAILS BELOW SUPPLIMENT Tl-!ESE PLANS AND SPECIFICATIONS. ~~ Steven M Ahles LANDSCAPE ARCHITECT P.O. Box 682 Cardiff, California 92007 0.11 2538 n;nf,32.0288 NVt 441 luldata 76ll632.0289 (f) z <( _J a.. 1--z w ~ w > 0 a: Q_ ~ w a.. <( 0 (f) 0 z :5 SET ISSUEC a: w 1---z w o<t: I-Oz a: a: <t:o WU.. (f) _J w<t: a:O LOoo ,,.... <( <( ..... mm 1-(J)(J) _J _J 0 a: a: <( <( _JOO ID MAY 98 SHEET REVISIONS: DATE PLAN CHECK 15 JUL 98 PLAN CHECK 2 12 AUG 9H WAIL.SPERM 8 OCT 98 WALL, S. PERM 30 NOV 98 □PAWN BY sma CH~CKED BY: PfDJECT NO: ':l812 SHEET TITI_E: SCALE SHFET NO, L-6 OF "AS BUILT" APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PREQSE LOCATION OF PLANTING AREAS. ~i? Af-c1-f 11W:[ ITTLE ·-- 1----+-----t-------.. -· ......................... . I---+----+-------------···· .. ··· ..... -··--·-·---+--+----+----+--~~ I----+----+-------------,·,~,·"''"'•'••· ··"-""'----~ .... ,~~--,,·-···4-----+-----< 1----+----+--------------····-,-····· ..... REVIEWED BY: ~.f;?/ac~~ INSPECTOR IRRIGATION PLAN FOR: LOT bS CARl.56AD RESEARC!-1 CENTER [" CM.UJ.D. J06 NO. 98·216 SHEET 1( I 1,::;::,..r ' ......, ,,_... I I BUILDING II 33,S'33 SF I w I z _J .n ' I -' t--o w ~ I ~ «) <( w w ~ «) I ~® \4_}.3 -~ -Ill I _-lj_4 . ... _ ......... _ Ill r -----;...__ ...... , .... ,; ... ,_,_:: ~ i ·--= I KEY MAP ~ I I HORT~ NT5 I ; i1: J r :( Ezj,, .. ,.v: .. _ Gti--f~--,,,=_iffilH~--,-D :§ ___ .i ::;'~-_-,.,.._;=-fJ--__,Jpi4f-- • - \ . I I :/ I I ' 1/ 1/ 1/ 1/ ' I 1/ 1/ I . -<,7 I , I /I I ! ---------,_ I I I I ,31, ! ' l' i IRRIGATION NOTES I. ALL IRRIGATION 1-lEAD&, VALVE&, ETC. ARE DRAWN DIAGRAMMATICALLY± l"(RIGATON CONTRACTOR 51-lALL ADJUST TO PROVIDE ADEQUATE COVERAGE AS REQUIRED DUE TO MINOR SITE DRAWING DISCREPANCIES. 2 IRRIGATION PLAN 15 DIAGRAMMATIC± LOCATE ALL IRRIGATION LINES, EQUIPMENT AND APPURTENANCES WITl--llN PROPERTY LINES AND OUTSIDE OF PUBLIC RIGl--lT OF WAY. 3. CONTRACTOR SHALL GUARANTEE Tl-IE ENTIRE SYSTEM TO BE FREE OF DEFECTS IN WORKMAN5!-IIP AND MATERIALS FOR A PERIOD OF ONE YEAR FROM FINAL ACCEPTANCE. 4. CONTRACTOR 5--IALL VERIFY WATER PRESSURE AT P.O.C PRIOR TO BEC,iNNING WORK± NOTIFY LANDSCAPE ARCI-IITECT IMMEDIATELY OF ANY Dl5CREPANCIES. 5. CONTRACTOR'S POINT OF CONNECTION 51-!ALL BE DOWNSTREAM OF WATER METER PIPE BETWEEN METER AND BACKFLOW PREVENTER 51--lALL BE SCl--lEDULE K HARD COPPER b. ELECTRICAL P.OC 51-lALL 5E SPLICE TO 110 V POWER PROVIDED BY Ol1NER ADJACENT TO CONTROLLER LOCATION. 1. PRESSURE MAINLINES SHALL 6E INSTALLED EIGil-lTEEN (18'! INC!-IES DEEP AND LATERALS TWELVE (12'! INC!-IES DEEP. 8. CONTRACTOR 51-!ALL INSTALL TI-IRUST 6LOCKS (I CU61C FOOT OF CONCRETE! AT EACl--1 Cl-lANGiE IN DIRECTION OF PRESSURE MAINLINE. 9. PRESSURE TEST MAINLINE FOR 24 1--lOURS AT 125 P.5.1.. 1-IAVE INSPECTED AND APPROVED BY LAND. ARCH 4 CITY INSPECTOR P"slOR TO BACKFILL. 112) AUTOMATIC VALVES ARE TO BE IN PLASTIC VALVE BOXES WITl-l ONE CUBIC FOOT OF PEA GRAVEL UNDER EACI--VALVE. II. CONTRACTOR 51-lALL PROVIDE EXTRA Wl"sf TO FURTI-IEST VALVE IN EACH VALVE CLUSTER 12. CONTRACTOR SHALL PROVIDE BALL VALVE IN PLASTIC BOX TO SEPARATE VALVE CLUSTER FROM MAINLINE. 13. LOCATE VALVE BOXES, ETC. IN Sl--lRLIB PLANTING AREAS WI-JERE POSSIBLE 14. PLACE QUICK CCUPLERS/1--lOSEBIBS NEAR VALVES AND SEPARATE FROM MAINLINE WITH BALL VALVE. IS CONTRACTOR Sl--lALL PROVIDE LINE SIZE Cl--lECK VALVE PER PLAN AND AS REQUIRED TO PREVENT LOW HEAD DRAINAGE. lb. LOCATE HEADS 3' MIN. FROM CURB5 AND WALKS AND b' MIN. FROM BUILDING!& AND lJALLS. 11. FLUSH A-L P'PE PRIOR TO IN5TALLING 1-lEADS. 18. CONTRACTOR 51-IALL ADJU5T 1-IEAD5 TO PROVIDE EVEN COVERAGE AND AVOID TI-IROWING WATER ON BUILDING&. WALL5 AND PAVEMENT. 19. OBTAIN AN IRRIGATION COVERAGE APPROVAL FROM LANDSCAPE ARCI-IITECT PRIOR TO PLANTING. CONT ACT LAND5CAPE ARG--llTECT AND CITY INSPECTER AT LEA5T 24 l--lOUR5 IN ADVANCE OF IN5PECITON. 20. R15ER5 TO BE GREY &Cl-I. B0 P.V.C., NO WI-IITE PVC± SHRUB RISERS TO BE 18' ABOVE FINISl--1 GRADE. 6U66LER5 b' 21. AT 30 AND AGAIN AT 90 DA'f5 AFTER COMPLETION OF PLANTING. CON""RACTOR SHALL ADJUST CONTROLLER PROGRAMS TO WAcR AT A MORE CONSERVATIVE RATE. 22. OltlNER 51-IALL AGAIN ADJUST WATERING RATE DOltlN ONE YEAR FROM COMPLETION DATE. 23. IRRIGATION CONTRACTOR S!-IALL MAINTAIN T,-!E SYSTEM FOR A PERIOD OF NINETY (90! DAY& OR UNTIL FINAL PLANTING ACCEPTANCE (Wl-llC,-!EVER 15 GREATER) AND WATER AS REQUIRED. Steven M Ahles LANDSCAPE ARCI-IITECT P.O. Box 682 Cardiff, California 92007 Cl) z <( _J 0.... 1-z w ~ w > 0 a: 0.... ~ w Q_ <( (.) Cf) 0 z ::5 760.632.0288 fax/data 7Ml.632.0289 a: w 1-z w o<( I-OZ a: a: <(o wlL Cf) _J w<( a:O -L.!) 0 0 c.o <( <( en en I-Cf) Cf) _J _J 0 a: er: <( <( __J 00 ; I' ' \ SET IssuIn 10 MAY 98 BUiLDING: ill 2'3,336 SF FUTURE ( I \ IRRIGATION PLAN 20 I 40 Fl NORT!-l 1 rllllllllllllllllllllll 1 J 11111111111111111111111.,.,._111m1111111111111ml1111111111111111111111 SCALE I i I - i ! /41 l l I l l I ' [ / I ' l ' ' I ' ····, ! I ' ' I ' ' i SEE SHEET 6 FOR IRRIGATION LEGEND ' I • l'j.2 ! ! ~~ SHEET REVISIONS rJATI PLAN CHECK 15 JUI. 98 PLAN CHECK 2 12 AUG 91: WALL, S PERM 8 OCT 9!l WALL, S. PERM 30 NOV 98 ½' I DRAWN BY sma / CH[CKED BY; PROJFCI NO: p' ! 5812 } S1-EET -Ill.I , .d)MAT INE SCA.E: \ & SI -:FFT NO.: SEE 51-1EET -b /I" L-7 /' APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. "AS BUILT' ~A lC0 TITLE REVIEWED BY: rNkrif£i::rc ,L OF ~ ~U\..-. 'tl. DAlE --+-----+--+-------<l~~Hl~_c_1TY_o_F_c_AR_L_s_BA_o~~ PLANNING DEPARTMENT ~j 1-----+----+-----------------l-'' --·-·-···--+---+--+-----l 1-----+----+-------, .. ---~ .. ··-··----------+-----lf-----+-----l----1 IRRIGATION PLAN FOR: APPROVIDc LOT 6S CAAl..56AD Fi!ESEA~ CENTER SHEET ~====:::'A::':'=:=:"::=:':,~=====::::;-;::======-=-=-=-=-~ ~~As!lTE[11l~IN~rnA=LlC~~~fil~~'M~J~~~r=======tD=A=TE==tN=rnA==L=~~DAdTE::~tl]NmfALZ:J I g:DBY~, 11 PROJECT NO.' 11 DRA3~1-ILNO., REVISION DESCRIPTION ' FIELD BK, --FD 4S" _ _ ., LAND. ARCH. CITY APPROVAL OTI-IER APPROVAL CMJU.D. J06 NO. '38-216 &OIL f'l'il:FA~Tla. AND FINISH Gri<APll-l'.l PART I -6ENE1s,11_ I.I DE5CRIPTla. A IIXJfsK INCLUDED, f'r<EPAAATla. OF $!'ACE STRATA OF &OIL FDR FLANTING INCUIDIN:., 6lIT NOT Nl:Cl:~Al<IL Y LIMITED TD, t TOPSOIL FLACEMENT, 2. SOILS TESTING, :l. FLACEt'fNT ANO INC(WORA Ta-I OF &OIL AMENDMENTS, 4. FNl51-l CiRADING, !>. ANY n-lCIDENTIAL ~ NOT 5HO.iN DR SPECIFIED U!-IICH CAN Isl:~ Y BE n-lFER<l:D AS FART Cf iOCJf<K. El. "1:LATED ~ FtANTll-l'.l n;EES, 5HIUlS AND ~GOYER l.l ol.lllMITT ALS TEST Rlc!lULTS DELIVERY STATEMENTS 1.3 QUALITY AS!iURANC!: A lll?fiiK 51-JALL ElE F'E~D FER ElEST STANDAWS OF PRACTICE RELATING TO VARIOUS TRADES l.l,JDER Ga.TINJOIJS !iUF'ERl'ISla. OF cct1F'ETENT FOREMAN, CAPAEILE OF INTERFRlcTIN:. DRAWINGS AND SF'ECIFICATIM. B H=RBICIDE APPLICATOR SHALL BE LICENSED 13'!" &TATE Of CALR>f;l,IIA 1.4 DELIYERY, STC>li!AllE AND HANDLIN:. A CQIITAINER5 5HALL SE LNOPENED AT DELl\ll'RY AND "1:SF'ECTl\11' LA6EL5 SHALL !lHDilJ CCNTENTS. 13. &To.£ ca.T AINl:RS OFF THE c.1'0tND AND PROTECT FROM THE IIEAMR. 15 PROJECT SITE CONDITIM A 11!-iEN EXISTIN:. /STOCKPILED/ SOIL 15 AVAILABLE Ga.TRACTOR SHALL YERFT THE GlUANTITY, LOCATla. AND 11!-iEN SOIL CAN ElE MOVED NTD THE FLANTING AREA STOO<FILED SOIL 15 TO MEET CONDITION& Dl5CRll3ED N 5ECTla. a. MATEl<IAL STANDAl<DS. 13. NO 501L 5HALL ElE MOVED n-lTO Ai<EAS ~ EITHER THE &OIL DR EXISTIN:. GRADE 15 TOO IIET DR DRY, DR 11!-iEN DELETERIOUS MA TEl<IALS Ai<E PRESENT. PART 2 -PRODUCTS 2.1 TOPSOIL A. SOURCE, ffi'-SITE ElORROJI TAKEN FRCM 5CU~ ACCEPTAElLE TD LANDiiCAFE AR::HITECT. 13. ACID-ALKALINE l<i'J'l'.lf, pj Hi 10 1£> C. Fl<EE OF FESTS, FEST LARVAE AND MATTER TOXIC TO FLANTS. D. FE~ OF ~ANIC MATTEl'o l% MINl1UM. E. MAXNJM ;:,; ElY VOLl.l1E St.Au, CINDE1'5, STa.ES DR DTI-lER EXTRANEOUS MATERIAL DYER 112' DIAMETER F. FREE c:f NOXIOUS lll=D SEED, PAT~C VllilJSES, HEfif!ICIDES, DR CIEMICALS TflAT n-lH161T GROU/114. G_ TESTS AND 5,,l/'1FLlt-l:, c:f TOF50IL I. FROVIDE SOIL SAMPLING FRCM 1lffl LOCATla.5 AND !iU6HIT TO CERTIFIED l>6Ra-lCMIC SOIL TESTING l.A'90l<ATDRY. OOEIMIT LAOORATORT TO FRDYIDE TESTING 10 CITT FDR AFFRDYAL PRIOR TD TESTlt-1:,. 2. TESTf>. ~IC MATTEls, NUTl<IENT ANAL '!"515, TEXTIJRAL ANAL Y515 AND SALINTY TEST PROVIDE TEST "1:SULTS AND AMENDl"l:NT f<!:W11ENDATIOO BY TE5TN6 LAB TD LANDSCAFE ARCl-llTECT AND CITT ~IOR TO AMENDMENT DELIVERY. CITT SHALL AFFR0\11' TESTn-t; LAB. AND l<Eca-te!DATIOO PRIOR TO AMENDMENT DEU\ll'RY 2.l SOIL CONDITla-lE1'5 A PEATc CANADIAN FEAT MOSS B. HEREllCIDES, AS REGlUIRED Ufa. LAND SCAFE ARCJHTITECT'S AFFROY AL. C. FERTILllER I. f'l'il:PLANTING FERTILIZER 5HALL ElE Lc:l'IG LASTING, COO!<OLLED "1:LEASE, UN~, FREE flCWI~ !iUITAElLE FDR APPLICATla. WITH ~D EGlUIFMENT AND SHALL Ga.TAIN Mc FOLLCWING Mln-ln-lUM AVAILABLE ~TU& El'!" ~IG,1-ll OF PLANT FOOD, FDR LAUN AREAS, N-F-K RATIO AS REGlUIRED FRa1 SOIL l<EFORT FDR 5HM AREAf>. N-P-K RATIO AS "'1:GlUIRED FRCM &OIL REFORT. l. F'OST PLANTING FERTILIZER SHALL BE Cl<6ANIC BASE, MOO ElUl,NING, &LCW "1:LEASE Fm FLCWING, SUIT ABLE FOR AFFLICATla. WITH AFFl<O\ll'D EGlUIFEMENT WITH THE FOLLatlll-l'.l Mn-llMlM AVAIABLE PERCENTAGE5 OF 11.El(illl c:f FLANT FOOD WITJ.l 11sACE MINE~S OF 3'-!Ra-I AND 3it. SULR& FDR LAUN AND 5Hl<IJ6 Alsl:AS, N"F-K RA TIO c:f 14-1-3 3. Fl.ANTING TAEILET& SHALL ElE T~ Y CCT'ffESSED CHIF TYPE COMMEl<ICAL FLANT TABLETS WITH THE FOLLOIJIING AVAILABLE FEl<CENTAGE5 OF 11.Elr.\f!T Cf PLANT FOOD, FDR 21 GRAM TABLETS, N-F-K ~TIO Cf 2e>-le>-!i FDR!'> DR 1 GRAM T Al3LET5, N-F'-K RATIO Of: ~-6-6. D. ~ANIC SOIL AMENDMENTS, DERIYED F!Ut l<EDILOOD DR FIR 13AFIK WITH 5E\II'~ c;RADIENT DE!\REE5 Of 6"1:AKDa.lN, NON 1a.1c UETTING AGENT, STABLIZED WITH NITRa;EN (1!15'! AS FOLl.OUJ5, I. SALNITT, SATURATION EXTl<ACT Ga.Dl.t';TlvlTY ieCE! NOT TO EXCEED 1.15 AT 2!i DEGRff& CENTIGR4DE. l. Dt,tjANIC eolTENT, MINIMll"I 90\ BY 11.Elr.\fll 3. pH, 55 10 &l>. 4 Ga.TIN!~ NO SLllXiE OR A\1"'1AL MAN.JI<!:. E. MINERAL&, I. SOIL !lULRJR rs! SHALL ElE ELEMENTAL SULRJR /~t,/ MNNJM. 2. FERl<CW SULFATE SHALL 13E FELLETED DR 1\RANULAR FOO Ga.TINING NOT LE66 THAN lat. METALLIC lr.a,I. MATERIAL SHALL ~ TO THE AGRICULTU~ CODE OF Mc STATE OF CALR'OlsNIA. 3. AGRICUL ~ G'T"F!ill1 rcaS04-lHlD/ SHALL BE GG1'it'IEF-GIALL Y PROCE55ED WITH MINIMJN 00'£ GRADE crnTANING 14% MINru-1 cctl61NED SULFUR 4. LME !GaC03! SHALL SE CALCIUM CA~TES LIME F SOIL FENETRANT, '&ARVCN' BRAND. Ci ILIA TER L SCURCI:· IRRIGATla. 5'1"5TEM POC. 2. G:IJALITT, FOTAl3LE (RJTURE Fl:CLAMED! FART 3 -EXECUTla. 3.1 INSf'!:GTla. A EXAMINE CiRADE TO RECEIVE SOIL FREFARATIO. TD A5SURE ll.tJliK OF OTHER TRADES HAS ElEEN c.a1FLETED. 13. \ll'RIFY 6RADE WITH LANDSCAFE ARCl11TECT PRIOR TO BEGINNING SOIL F'REFARTATICN. C. NO SOIL F'REFARATla. SHALL 6E FEsfoi;riED UNTIL ALL 5~5 AND WALLS AND CMTl<UCTla. ITEMS /INCLUDIN:. MAINS AND DRAl'i66!: LINES/ HA,{ 13EEN INSTALLED. D. Tl4E SITE SHALL ElE Fm OF IIEEDS, TRASH AND DELETERIOUS MATERIALS PRIOR TO SOIL Ff<!:PARATICI< E. YERFY THAT FLANTS TD REMAIN HAVE 13EEN lNDlofflJBED. F. DO NOT PROCEED WITH SOIL FREFARATla. UNTIL il'JSATlal=ACTDRY Ga.DITla.5 Al<!: CORRECTED 31 SOIL& TEST f<!:!iUL T5 ffiOVIDE TEST RESULTS TD LANDSCAPE Al<CHITECT AND GITT LANDSCAPE N5f£CTOR CO\Fli;!-1 SOIL AMENDMENTS PRIOR TO APPLICATION AND ElACKFILL. /SEE FLANTll-l'.l NOTES~ l ~. SHEET V l3 f£RFORMANCE A SU6501L, I. ~FY 5Ufl501L IN ALL AREAS /EXCEPT SLDFES 3,1 OR GRlcATERJ TO e€ FLA'ITED TD DEPTH OF 1, INCHES f'RIDR TO PLACEMENT OF AMENDMENTS AND TOFSOIL M SOIL $!'ACE SHALL ElE MADE LOOSE AND FRIABLE. 2 REMO\/!' ROCKS AND OTHER oeJECTS OVER 2 n-lCl<ES n-1 DIAMETER El. TDP601L, iNCT AFFLICABLEl> C. IN~Tra. ct-SOIL AMENDMENT&. I. PLACE ADDITl\11'5 UNIFOOLY n-1 ACCORDANCE WITH SF'ECIFICATa. AND SOIL TEST l<!:SULTS, INCORFORTATE TO DEPTH c:f & n-lCHE5 BY ROTOTILLING DR OM!< AFFRO\ll'D MET~ l RAKE, DRA'i, ROLL AND SMOOTH THE 5UlifACE UNTIL FREE c:f HOLLO\ll', AND RIJX,E& AND IT ro.FORM5 TO EST Al3LISHED GRADE FLUS OR Mn-111\JM I INCH IN le> FEET. 3. APPL r ~-EME!ir,ENT HEfif!ICIDE N ACCORDANCE WITH MAJIILFACTU"1:'& AND P6ENCT Fl:GlUIRMENTS. D. Fn-llSH GRADE, I. UPON c.a1FLETla. OF ROTOTILLlt-1:, AND TOPSOIL FLACMENT, ALL AREAS SHALL ElE ILIATEl<ED TO 5EffiE SOIL. 2. lll<EN Ti-£ SOIL ~AS DRIED SifFICIENTL Y TO ElE "1:ADIL Y ll.tJliKED, ALL LAUN AND FLANTING AREAS 5HALL BE GRADED TD FREVl'1JSL Y ESTABLISHED i>RADE5. 3. 6RADE5 NOT OTHERll!l5E INDICATED SHALL ElE l.NlfOl;!1L Y LEVEL DR SLOPING BE111JEEN GIVEN ELEVATIClll5. FNISH GRADE 5HALL ElE SMOOTH, EVEN, UNIFOO Fl.ANES WITHOJT ABRUPT CHAN::;E OF ELEVA TICN. 4. SOIL A!<!:AS ADJACENT TO BUILDNS5 !il4ALL SLOPE ,l!UA'f FRCM BIJILDNS TO ALLOJ/ FOR A NATUm !,!,IN OFF OF IIIATER. AND Si.lfifACE ILIATER SHALL BE DIRECTED AS INDICATED ON THE DRAWINGS 6'l' REMODELING $!'ACES TO FACILITATE NA1UM i;a.N OFF OF 111A TER !o. Lall 5POT5 AND POCKETS SHALL SE GRADED TO D~IN F'ROf'ERL Y, MANTAIN 2% MNIMUM 5LOFI:. &. FINISH GRADE ct-ALL FLA'ITING AREAS SHALL ElE ElRlml-lT FLUSH WITH cu.65 AND FAYING TD ASSURE FC51TIVE DRAINA6E OVER THE $!'ACE. 1. MAKE MNDR ADJUSTMENTS TD Fn-llSH GRADE AS DIRECTED er THE LANDSCAPE ARCl11TECT. 3.4 CLEA\IUF A. IMMEDIATEL '1" CLEAN IJF SPILLS, SOIL, CONDITIONERS a. PA\ll'D AND Fn-ll&HED SUl,fACE Alsl:AS. 6. REMOVE DE6R15 AND EXCESS MATERIALS FRa1 FRDJECT SITE. END OF 5ECTla. FLANTlt,t, Tisl:ES, SHlsl!lS AND ~R PART I -GENERAL I.I DEilCRIFTION A. ll.tJliK n-lCLl.PED, PROVIDE ALL LABOR, MATERIALS AND EGlUIFMENT Fl:GlUll<ED TD COMFLETE ~ a. DRAIIIIN::;5, COMFLETE IN PLACE AND AFF'RCYED, INCLUDING 6'1" NOT Nl:CESSARIL Y LIMITED TO, I. FIRCHASE OF FLANTS l. AL-FLANTING, n-lCLUDING GRCUNDCO\IER 3. INSFECTION AND CERTIFICATra. 11 GlUALITY A55URANCE f'Ef;FOf,,11 n-1 ACCORD~ WITH ElEST STANDARD$ OF PRACTICE RicLATll-6 TO VARlaJS TRADES ~ CONTNJOUS !iUFERVISia. OF CQ'lf'ETENT FOREMAN, CAPAElLE OF n-1 I El<J"Eli:I NG DRAWINGS AND 5FECIFICATION5. 13 EXISTlt-1:, SITE Ga.DITIONS A. PRIOR TO EXCAVATION OR FLACll-l'.l Of STAKES, LOCATE ALL ELECTRC CABLES, CONDUITS, SFRN::LER VALVES, l!TILITY LINES 50 THAT FRECAUTIM MAY 8E TAKEN NOT TD DAM/161: SUCH IMF'RO\IB"ENTS. IN EVENT OF CDFLICT ElETIIEEN 5UCI-I LNE5 AND PLANT LOCATlc:tJe, NOTFY LANDOCAPE ARCHITECT. FAILURE TD FOLLOW THIS PROCEDURE FLACES UPON Ga.n.ACTOR THE "1:5Fa.5161LITY FOR MAKll:i AN'!" AND ALI.L REFAIRS fOR DAMA'l-E "1:SUL TING FRa1 ~ HE1'SINDER. El. VERIFICATla. c:f Dl1EN51a.f>. ALL OCALED Dl1EN51DN!i ARE AF1'ROXIMATE. BEFDR1: l"ROCEEDNS, CARERJLL r CHECK AND \ll'RIFY ALL Dl1EN51M AND GlUA\ITrTIES AND 111EDIATEL '1" INFOla1 LANDiiCAFE ARCHITECT OF A'IY DISCis!:PANC"f 8ET11.EEN DRAWINGS, SPECIFICATION AND ACTIJAL Ga.DITIONS. PEl'fOlsM NO~ IN A'IY Al<EA lll-lERE THERE 15 SUCH A DISCREPANCY UNTIL AFFRDYAL FOR SAME HAS 13EEN C.1\/EN 13'!" LANDSCAFE ARCHITECT IA 5Ci-4EDULING I SECl.&JC!-.:i, A. A'1El< SOIL HAS BEEN FREFARl"D P!:R OOIL F"1:FARATla. 5FEC, IRRIGATla. SYSTEM 15 I-ISTALLED AND CONDITIOO AFI: FA~LE TD PLANT, "1:QJEST AF1'ROVAL TD FLA'IT. 13. IRRK:.ATla. AND FLANTlt,t, MAY BY Da.E Ga.CUl'i:RENTL Y, HCtilE'IER. FLANTIN:. ll.tJliK MAY NOT START IN ANY SECTION PRIOR TD INSFECTla. AND Af'f'ROY AL c:f IRRIGATION IDs!<. IE, !liJ6511TUTION5 NO 5ll65TITUTIOO FRCM SFECIFIED FLANT MATERIALS WILL ElE F'E"'11TTED UNI.ESS 5UBSTITJJTE MATERIALS Alsl: AFFRO\IED n-1 ADVANCE 6'!" UNDSCAFE ARCHITECT AND THE CITY, AND 5Ll651TUTIM ARI" MADE AT NO ADDITla.AL CHAJ;l;E TO OIINER IF ACCEPTED iiUl35TITUTE5 ARE OF LESS VAL\/!' THAN Ti-l05E INDICATED DR SPECIFIED, CCNTRACT FRICE WILL BE ADJUSTED n-1 AecoRDA\ICE WITH FRDYl51DN5 ct-~T. lb SIJElMITTAL5 A. 9J""ISH SOURCE OF MATERIALS IF "1:GI.JESTED El'!" OJN:R OR LANDSCAPE ARCl11TECT 13 IN ADDITICN TO ANY OTHER CERTIFICATES SF'EC!'IED, RJ""ISH A CERTIFICATE wrrn EACH DELIVERY OF BULK MATERIAL STATING SOURCE, GJUANTITY, TYPE OF MATERIAL, AND Tl-lAT MATERIAL ca-1FOFH> TO SFECl'k:ATICN. SUElMIT CERTIFICATES PRIOR TO START OF MANTENANCE P!:RIOD. 1.1 Ci!JARANTEE AND REPLACEMENT ALL FLA\ITS SHALc BE GUARANTEED FDR PERIOD SF'ECIRED N FLANTl-.:i, wrE:5. All'!" FLANT NOT GROWN:; FRDFERl. Y DURING THIS FERIOD SHALL SE l<EFLACED WITHn-1 SEVEN /1/ DAYS OF WRITTEN NOTICE. GUARANTEE MA'!' l3E EXTENDED IN CASES IF PLANTS ARE SLOW TO E5TABLl514. IF Ga.Tl<ACTDR FAIL& TD MJ,Q;: f<EFLACEMENT5 WIT\4n-l TIME LIMIT, OIINER MAY REPLACE THEM AT CONTRACTOR'S Exi=ENSE. FART 2 -PRODUCTS l.l PLANT GlUANTITIES AND t!'FES R»llSH FLA\IT MATERIALS n-1 GlUANTITIES AND SPACING ~ DR ~D FOR EACH LOCATION, Cf SA::CIES, KIND, SIZE, ETC. AS 5"11-IElOLIZED AND DESCRIBED IN PLANT LECiEND. l.l PLANT MATERIAL 5TA\IDARD5 A ~TIJRE, PLANT NAMES LISTED n-1 FLA\IT LEGEND COlf'Ol;f1 TD 'STANDAl<D FLANT NAMES' ESTA13LISHED 6'1" AMERICAN COMMITTEE a. HDRTICU.. TURAL Net1ENCLAME, FDR NAME& NOT COYEisfO Tfi:REIN FDLLOJ/ LOCAL NURSERY CUSTG11. CALIFOl<NIA NATIVE PLANT Sf'ECIES FER 'JEP&a. MAN.JAL'. El. Ga.DITION, SYMMETRICAL, TYPICAL FDR VARIETY AND 5FECIE5, SCllND. HEAL THY, VIClOROUS, FREE OF DISEASE, INSECT f£5T5 DR EOOS. HAVIN:. HEAL THY, NOl<M<\L ROOT 5Y5TEMS, IIELL FITTl>l'.l CONTAINERS 6li1 NOT TO FOINT OF !3EING ROOT !30JIID. DO NOT fflJNE PRIOR TO DELIEYERY. IN ND CASE SHALL Tl<EE& ElE TOPFED ElEl'DRE DELIVERY. C. DIMENSIOO, MEASURE HEl~T AND Sf'r<EAD c:f PLANT MATERIAL WIT~ BRANCHE& n-1 NC!a1AL FCSITICN. MEASUl,f Tlsl:E CALIF'ER 2'-tl' ABO\/!' IJRADE. PROVIDE ALL FLANTS AT Mn-lMJM Dl1EN51a.5 NDICATED a. FLANS, UJ.Elsf CALIPER DR OTHER DNENSIDNS OF ANY PLANT MATE~ALS Alsf CMITTED FRa1 PLANT LEGEND, IT SHALL !3E AVERAGE &Toa:: FDR TYPE LISTED D. n-15FECTla.5, ALL PLA'IT MATERIALS Al¢ SU8JECT TO INSF'ECTICN AND AF'Fl<OYAL ElEfOl,E F'LA'IT"'-5. ALL Fl.ANTS !iUPFLIES TO ~JECT /IU-1ETHER Fl.ANTED DR NOT! Al¢ !iU3JECT TO REJECTICN. E PLANT Ll5t AS INDICATED CN PLA'ITING FLAN F. SIZES c:f FLA'IT5t FER PLANT LEGEND. Ga.TAINER &TOCIC /1, ,, MV 15 GAi.LOO ~ HAYE &EN GFlOlN IN crnTAN:1'5 FOR TIME SUFflCIENT TO DEVELOP ROOT GROil/TH SUFflCEIENT TD HOLD SOIL BALL TOOETHER TO SIDE AND ElOTTo:1 OF Ga.TAINER IN UIHIC~ IT WAS DELIVE!sED. Ci FLANTS NOT APFRO\IED, REMO\/!' FRCM SITE IMEADIATELY AND REPLACE WITH SUITABLE FLANTS. LANP5CAFE ARCHITECT MAY "1:..ECT ENTII<!: LDT Of: FLA'IT5 REPRESENTED ElY DEFECTIVE SAMPLES. l.3 SOIL CONDITIM -SEE SECTla.5 W GRADlt,t,, DRAIN.A'.iE AND SOIL F'REFARATla. STANDARDS. FART 3 -EXECUTION 3.1 PLANTI~ -GENERAL A. RELATIVE P051TIW OF ALL TREES AND Fl.ANTS 15 !iiJ6JECT TO AA'ROYAL El'!" LANDSCAPE ARCHITECT AND SHALL, IF NECESSARY, BE RELOCA1ED AS DIRECTED AS FART ct-W,.TRACT. 6. PLANT FIT5 SHALL ElE MINIMUM WIDT~ lX LAR,ER T~A\I RCOT ML. II' II/ATER WILL NOT DRAIN FRC!1 HOLE 0\/l'R Nl~T. TAKE CAIJtlON NOT TO 0\/l'R WATER FLANT5. C. 5.ET 50 THAT, 11,1.EN 5.ETTLED, Fl.ANTS ARE I IN. HIGHER THAii FINISH GRADE THAN THE'!" 60RE TO CCNTAINER. PLANT IN CENTER OF PIT, 6AOOILL UIIT~ MIX PER PLANT~ N01E&. NO $OIL IN MUDD'!" COOITION SHALL !3E USED ON ElACKl'ILLn-lG. NO FILLn-«:. WILL ElE FERMITTED ARCIJND TRLQIIK& OR STEMS ALL 6RC1<EN DR FRAYED ROOTS SHALL BE F'ROf'Ul Y CUT. D. DO NOT ALLCW FLANT5 TO DRY 6EFORE OR ILHILE PLANTING. KEEP EXPOSED RT& MOl&T ElY 11:ANo OF WET SAlllDUST, FEAT MOSS, DR 6Ul<ILAP AT ALL TIMES DURI~ PLANTING. DO NOT EXPO&E TO AIR 111-llLE BE~ PLACED N GROJND. WILTED PLANTS, IN PLACE OR NOT, WILL NOT BE ACCEPTED AND SHALL ElE REPLACED AT CONTRACTOR'S EXFENSE. E. LANDSCAPE ARCHITECT 514.ALL MAJC:E PERIODIC INSFECTla-1& DURING FLANTlti. PLANTS NOT PROP!:Rl. 'l' HANDLED, !lPOTTED OR PLAN1ED SHALL ElE 5UElJECT TO Fl:MOVAL AND Fl:FLACE11ENT. F. n-1 THE EVENT T~AT UNDE~ CON&Tl<IJCtla. Uk?RK DR OElSTlsUCTla-1& Alsf ENCOJNTERED ALTERNATIVE LOCAITCNS WILL ElE SELECTED ElY LANDSCAPE ARCl11TECT. LOCATla. OPERATION WILL 6E DCNE AT NO EXTRA COST TO O\INER 32 FLANTI~ OF TREES A. SPECIMEN TREES SHALL BE AFA<O\ll'D ar LAND5CAFE Af<OllTECT WITHIN 3,z, DA'1"5 OF THE AWARD OF CONTRACT OR 48 HOURS ElEFDRE DELIYEER'f, lll-llCIHEYER W"IE& FIRST. SFECIMEN TREES DELIEYERED THAT AR DAMAGED OR CHANGE!) FRa1 THE URITTEN AA"l<OVAL Al(!: SillJECT TO REJECTION. 6. NO TREES IS GALLONS AND OVER SHALL ElE FLA'ITED IN A HOLE THAT WILL NOT NATURALL '1" DRAN IN 24 HOlJR5 A<TER ElEn-lG FILLED WITH WATER. CCNDUCT TEST TO MAKE THIS DETEr-r!INATION, AND NOTIFY LANDSCAPE ARCHITECT OF Fl:5LILT PRIOR TO PLANTING. C. FLA\IT ALL 5ffCIMtN5 =1R~ IN 50DDED OR GROUND GOYER AREAS ElEFORE FINAL AifPARTIGN OF THO&E AREAS. D. STAKE AND GUr A..L TREES INDICATED ON FLANS AND AS REGlUll<l:D TO PROVIDE OPTIMJM STABILITY. 3.3 PLA'ITING !\14!;1J65 AND GROUND COVER A. REMOVE ALL VINES FRa1 ST AKES, IJ,ITIE, AND SEGUREL r FASTEN IN All APFRO\IED MAN-ER TO IIIALL, FENCE, OR OTHER 5Lllil'ACE NEAR 10 Ul-llCH THEY ARE FLA\ITED El SET N CENTER OF PIT, IN VERTICAL POSITION, 50 THAT AFTER ALL0\!111-6 FOR ILIATERING AND SETTLING, CROJN OF ,;,ooT13ALL 15 I IN. A13C\II' SiJRROUNDI~ FINISH r.RA0E TO Fff\lENT IIIATER ACCltlJLATICN. 3.4 I-ISTALLATla. OF GROJND COVER A FLANT GROJND COVER n-1 AREAS DESIGNATED a-I PLANS. El. KEEP c.ROUND COVER STORED a. THE SITE MOIST AND FREE OF INSECTS AND IIEEDS. C. 00 NOT PLA\IT ~ GOYER UNTIL INSF'ECTED EIY LANDSCAf£ ARCHITECT. D. PLANT FLATTED r,R{)'J;lJ COVER WITH FLAT &OIL NTACT WITl-l ROOTS. :lb FERTIL IZEI< INSTALL CHIP TYPE FERTILIZER TA6LET5 FER THE FLA\IT~ NOTES. 3b WATER EIASINS FffFA!sE ~ISED WATEI< EIASn-1 AS WIDE AS FLANT ML AT EACH FLANT. IIIATER ~LY, 6ACKFILLING ANY VOIDS WIT~ ADDITIONAL FREFAis!:D FLA\ITlt,t, MIX DD NOT EIASN FLAT SIZED FLANTS. REMOYE ALL 13A5N5 PRIOR TO PLANTING OF LAllN AND GROJNDCO\ll'R. 37 WATERIN:. A. AFFLY IIIATER, IMMEDIATELY AFTER FLANTING, TO EACH 1"1:E, ~-VINE AN) GRaJNDCOVER Alsl:A B'r HOSE. APPL T ILIATER n-1 A MODERATE SMAM n-1 FLANTlt,t, HOLES UNTIL Mc MATERIAL AOOUT THE ROOTS 15 MOIST FROM OOTTCM OF HO..E TO TOP OF THE c.RaJNIJ. El. FDLLOWl)t'; THE PLANTING c:f GRO!MlCO\ll'R PLA'ITS, IMMEDIATEL '1" AND THORO.GHL Y IIIATER EACH PLANT. C. WATER FLA\ITS NOT EFFICIENTL r WATERED WITH EXIST~ l~C.ATla. SYSTEM WITH HOSE. D. APPLY WATER n-1 SUFflECIENT G!JANTITIE5, AS OFTEN AS SEASONAL CONDITla.5 "'1:GlUIRE TO KEEF THE t\RO..ND !1015" AT ALL TIMES TO THE DEPTH Cf THE ,;,ooT S'!"STEM OF c.RA55 AND Fl.ANTS. 3.8 FROTECTla. CA"1:FULL '1" AND Ga.Tl>IUOU5L Y PROTECT AJ,EAS NCLUDED IN Ga.TRACT, l<CLLP~ FLA'IT MATERIALS, FENCE SIJFFORTS, ETG_ UNTIL FINAL ACCEPTANCE. 3.~ CLEA\! UP UFOI c.a1FLETION OF~ "1:MOVE lilJl3!31SH, TRASH, AND DEElRIS "1:SULTING fR()'1 Clf'ERATICN. "1:MOVE EGlUIFMEIII AND "'1FLEMENTS OF SERVICE AND LEA\/!' ENTlf<E AREA NVOLVED IN A NEAT, ACCEPTABLE CONDITla-1 SllCH AS TO MEET AF1'ROV AL c:f LANDSCAf£ ARCHITECT. 110 MANTENANC!: A MAINTAN ALL FLA'ITING AREAS IN YOOROJS, T~RIVING CONDITla. El'!" WATERING. CULTIVATING. i'iFRAYlt,t,, WASHll-6 OFF IIIALK!l, AND A\IY DTI-ER NECESSARY OPERATla.5 DUl<lt,t, THE ENTll<E F!:1<100 c:f tlSTALLATla. AND ESTAElLl&-l"IENT MANTENANCE UNTIL FINAL ACCEFT ANCE. El. CALENDER MANTENANCE FEl<IOD SHALL BE CALCULATED FROM NITIAL ACCEPTA\ICE B'f LANDSCAf£ ARCHITECT. G. IMFROFER MAINTENANCE Ul-llCH MAY CAUSE M FOOR CONDITIC),j OF PLANTED MATERIAL AT TER'11NATla. c:f SCHEDULED ca.TRACT FERIOD UILL CAUSE FOS"Wa<EMENT OF Fn-lAL ACCEPT ANCl' OF 11m. crnTINUE MAINTENANCE OF 5UC1-1 AREAS AT NO ADDITla.AL COST TO OIJ,l,IER lNTIL IIXJfsK 15 ACCEPTED. D. KEEP ALL AREAS fREE OF DEBRIS, IIEEDED AND CULTIVATED AT NTERYAL5 OF NOT GREATER THAii TEN (Ii)) DAYS AFTER INITIAL ACCEPTANCE Cf All'!" AREA E. MAn-lTAn-1 ADEGlUATE PROTECTla. OF ALL Al<EAS. DAM/161:D AFl:AS SHALL ElE "1:FAIRED IMEADIATEL '1". f. POST FERTILIZE ALL AREAS AFTER T~IRTY /3<!)) DA'1"5 AND EACH SIXTY (&1!1/ DAYS THERlcAFTER OF MAINTENANCE WITH TU.ENT'!" (2e>! FaJNDS FER i,,z,e,e> SGlUAl<E FEET c:f POST FLANTNG FERTILIZER. c;. REMOVE ALL IIEEDS er HAND, AF1ER IIIATERING, AT THIRTY (3<!)) DAYS ,IFTER n-llTIAL ACCEFT.IJ'n. AFFLICATla. a OF DYMID OR TREFLAN DR AFFROVED ~ EMEf;l'.,ENCE lll=D CONOOL SHALL BE MADE 11!-iEN, n-1 LANDSCAPE ARCHITECT'S OPNla., PROJECT 15 INFESTED WITH 111'ED SEED At-P RJRTHER illDING ·w1LL !3Ea:11E A'l l.NNECE55ARY 13URDEN TO aJNER. 14. CALL FDR INSFECTla. AFTER EACH THIRTY /31!1J DA'r5 OF MAINTENANCE. I. MANTENANCE SHALL Ga.TINUE FOR PERIOD SFECIFIED n-1 PLANTit.:; NOTES. END OF SECTla. [Bl <----STI'<Al<Sf-lT HEADER-2x4" -,-.T-AKE-.-.-.-ACl-l-J_O_I ------!!iAKE 4' OJ::. wm-1 2 • l=.ACI-I JOINT ,---51.IGI-ITL Y CURVED H!cADicR• IV lx-4' 5T,t\G;ER JOINTS 4' MIN.., STAKE 3' O.C AND • EACH JOINT 8 REDWOOD HEADER ,--S~L 'r CURY'ED-(41 3/Ebt4' NAIL 12' oc.. Mli'l. ST AKE ~-OC. .. .<IND • 4' OC.. L.AMINATICN O'F6ET FIN l,RADI= NTS ,---SH"1:DDED Nln.ot.lZED BAl'iK l'IJLCH, 1-1/2 TO 2' DEEP, MOISTEN lfTER FLACEMENT ,---3' IIIATERll-l'.l 6ASIN =-lllll=c::IIIII • ,t--m~mr~FERTILIZER TABLET FER NOTES 11111 11111,~~~~~ ll3DEFTHOFHOLE --11111 .. 11.111 , --11 ~--AMENDED SOIL ElACKFILL =II 1=1111 ~--ROOTl3ALL ~----FLANTIN:. HO..E-SIZE FER &FECIFICA Tia. © (X}JT,Al'ER fvWOO s ~--GROJNDCOVER TO SE PLANTED FRCM FLATS, GUTTn-t:;&, LINE1'5 OR a.E GALLa. CCNT AINEJ,5 FER FLAIi ~--Fl<EF'Ai<ED SOIL-SEE PLANTING NOTES '1111: I 1111 11111 11111 l<EFER TD Fl.ANTING NOTES FDR ADDITla.AL SF'ECll'ICATM 1111 1111 ;';;-, &QFT_ PLANTS WILL COVER ")~. ••• ~ .. 4' 1 ••• &' I& • • • 8' 28 • • • • ••• le>' 4!'> 1._ ••• <.O .. . " 11' &4 -• .. . ~ l!o' 100 l__jSi_ J" L 18' 144 24' 2% 5GlUAAE 5PACING TRIAN::;Ut_AR !lf'ACN'i @ GROUND COVER PLANTING NOTE-ALL l!o c.AL I 24' BOX 11<EES SHALL ElE 51 AKED f-,; (_ \., PREVAILING WIND z:-c •~~~~~~ o---2' DIA FINE LODGE FOLE &TAKE I: .1 Cn-lCH TIE UIIGAL V. NAIL (Ely VITJ ~ -.I).-24' FOR IS c;ALt 32' FOR 24' BOX 1 4 FER TREE ,--2' Nlm?LIZED ElARK MULCH • ~--tt-4' IIIATERll-l'.l BASIN -=~]li=~r:::=:i..:.!s:::::JIHIITTii~-F=NISHc;RADE IPt-ts11111-FERTILIZER TABLET FER NOTES 1/3 DEPTH OF HOLE ! 1111 ·==· ---ORIGINAL ROOT 13ALL l --11 ,,......_ PLANT PIT-lx WIDTH. EGIDEPTH =tBALL : @ OOUBLE STAKED TREE I II SQ. FT l!o 44 le> 100 l!i& 22!:o 400 f O<"',' <. l NOTE, INSTALL ROOT 6ARRIER FER MAJIILFACTURER'S SPECIFICATIONS AND APPLICAElLE l"IJNICIPAL CODES. ~ -::-.c,>---0___ INST ALL Tlsl:E FER FLANTlt-1:, NOTES AND DETAILS, INCLUDING [I.JYING DR &TAKl-.:i,, BACKFILL, MULCH, FERTILIZER ETC. LJ•;Ji~~-----LOCATE BAf<l<IER AT FER"'1ETER CLllil35, ~I WALKS, IIIALLS DR 5Tl<UCTU"1:5 FDR GROUP INSTALLATIONS ,. M ---'4" 6RA\ll'L FNISHGRADE "===---LOCATE BARRIER AT FER"'1ETER OF FLA\IT FIT FDR INDIVIDUAL MES ., ,: . Llt!l-:,4IJ~~lj'.'.-,,Jdll-----ROOT BARRIER FER PLANTN', FLAN AND NOTES ;! -... ,,. ----Mn-llMlM PIT DEPTH EGlUAL TO BARRIER DEFTH FOR n.E~5 f<EGlUIRIN:. ROOT BA~ER COMPACT ElAOOILL ElELa!I @ TREE F(X)T BARRIER APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. TTTI.E REVIEWED BY: INSPECTOR Steven M Ahles LANDSCAPE ARCHITECT P.O. Box 682 Cardiff, California 92007 CJ) z <( __J CL 1-z w ~ LU > 0 a:: n... ~ w n... <( 0 CJ) 0 z <( __J 76Cl632.0288 fu/data 7M6320'fflll a: w 1-z w o<C :r:-oZ a: a:: <Co LU LL CJ) __J LU <( a:O LOO 0 ,,.., <( <( ~ CD CD I-CJ) CJ) __J __J O a: a: <( <( _JOO SET ISSUED SHEE~ RO:VISONS 10 MAY 98 DATE PLAN CHE:::;K 15 JUL 98 PLAN CHF.:::;K 2 12 AUG 98 DRAWN BY: sma CHECKED BY PROJECT r-0. 9812 SHl'~T TITLE SHEE.1 NO. L-8 OF "AS BUILT" DATE DATE , --+--+-----------+--·--:;_-_-_---r-+-,--_,I SHE8ET, I. _c_11Y_o_F_cA_R_L_s_BA_□~1~~I r-_ PLANNING DEPARTMENT FLANrlN6 DETAILS 4 SPEC5: APf'ffOVE(): LOT 6!; C~56AD RESEARCH CENTER SHEET i---D-ATE-=-+-1--111TIA----L-+---R-EVISI--ON--D-E-SC-RI-PTION---------+-c:-0Ac--:TE=-+cc1N:::mcc-ALc--+-coccAcc:TE;;c-J-;NTIAL=:-;--1 I 5:~BY:, ---11 ~ oo, 11 ~~ oo., LAND. ARCH. CITY N'PROVAI. O'Tl-EA APPROVAi. l..'::''='='~~--====--~-----~ C.M.IUD. J06 NO. ~-216 .. .. DO C -,, ll<RIGATICN S'ffiTEM PARTI-C:!EIERAL U DEOCR!f'TICN A IOClrl< lfQIJllEIJ, l!IR~TICN SYSTEM &l4a!N CN Dli!AWI~ AND &FECFIED ~N Cc:11'LE1E N PLACE. 1E51ED, AF'fl'<OVED, NCLIJDll't; art NOT NECE~L T LIMllED To, l CaMCTICN Cf SYSTEM TO EX15Tll't; WAlER 5IJPFl. Y 2. REYIEW Cf UTILITY Pl.MS ~~ OTl-tR ~ UTILITIES 1 TREN~I~ AND BACKFILL 4. ~p AND !lfl<AY l!IRIGATICN 5'r5TEM ,. AUTG1'1ATIC CCNT!ilOLcER Al>O F:13'10TE CCNTFl?L YAL 111:5 •. INCIDENTAL um NOT m?IJN OR 5FECIFIED 1114101 C,IJ\I REASCNA6L Y 6E NFERRED A5 PART OR AND NECESSAR!" TO PROVIDE A CCMPl.ElE AND OPERABLE 5T5113'1. 6RELA1ED lll'Ji;I( DOC1.MENTS AffECT~ IOClla< Cf TMl5 &ECTICN ICWJE, 6UT ARE NOT NECE55ARIL T LIMllED TO GENERAL CCNDfTICNS AND OT!i:R 51:CTICNS Cf TI-IE&E &FECIFICATICN5. ll F'Ei'!11T5, FEES AND CODES A OOTAN ALL Fl:i<l"IITS AND FAT 1'EaJl'1ED FEES TO ANY r.iOYEl<H'1ENTAL A$ICT ~~ JIJRl5DICTICN a-I CG1'1R.ETICN Cf ~ Fli:E5ENT SATISFACTORY EYIDENCE TO LiWSCAA: .IRC!lfTECT 111<11 lltlf<K 15 IN AecoRDANCE WITH ORDINANCE AND CODE REGlJll<El-eNTS. Al<R<\la FOR "5PECTICNS f<l:GlJll<ID 6T LOCAL ORDINANCE DUlsl1'11 CCN&mx;TICN. 13. ~ Wlnl AFFLICA6LE CODES, 5TAND~5. LAW5 AND '1EGILATICNS. NO'rrll~ N DRAW~ OR 5F!'CFICATll'.Ni r.JALL 8E cCNSOOlED TO FE,-l-:IT Nt1, CIN'OO~ lltJf<K. r.JaJL!l cCNSmx;rlCN DOCIMNT5 OR IN&TI.!JCTICNS Y/JRr A<l'.1'I AFOl<fMENTI01ED i<U..ES AND Rfilll.ATICNS, NOTFT LAND. Ai'l'.14ITECT, AWAIT N5TR11CTICNS 6EFORE F'RD::EEDI-I::; 111TH AffEClED ll.Ol,K. 13 Si\ffTY OOER5 MAINTAIN WA~IGN SIGNS, BA~ERS. SWRI-I::; '1EC2Jll<!cD 6T LOCAL ORDINANCE OR OTHER AW-U. l4 OOAI..ITY A55URANCE A USE ADEG!JATE NUMElE1s Cf 51':JLLED UXJF!Q'1EN, T~ T TRANED. EXPERIENCED N NECE55Af<l' CR,!FlS AND CtnLE1EL T FAMILIAR Wlnl &FECflC f<l:GlJlml!:NT5 AND METHODS NEEDED FOR Fi<OFEls ~Cf~ a ALL HA1ERAl.5 SflALL BE 1'EUI AND N NEAR FUfECT cCNDITICNS DECISICN Cf L/WSCAPE ~11ECT 15 FNAL IN DETEr.MNATICN Cf G!JALITY Cf MATERIALS, EC2JIA1ENT, umMANSMIP lb EXl5TI-I::; 511E CCNDITICNS A ACGlJINT SELF Wlnl ALL 511E CCNDITICN5. 5HOO..D UTILfTIES NOT 5IOJN CN PlANS Ill' FCIJO DURl-6 EXCAVATICNS, l"l1Q1f'Tl-T NOT~ LANDSCAFE ARCHITECT FOR N5TR11CTICNS FOR RJRnlER ACTICN. FAIJJJRE TO DO 5C WILL MAl:I CCNlRACTOf< LIAaLE FOR ANY AND ALL DAMAGE TMEf<ETO ARIS~ FRIJ'I OPERATICNS, ~T TO Dl5COI/ERY Cf 5IJCM UTILfTIE5 NOT 5IOJN CN DRPJJll-65. a MM MINOR ADJ.151!1ENTS TO~ 5T5TEM LAYOUT AS MAT l'lE f;EG!JIRED, AND ul'.)f;I( AllaMl EXl5Tli'l'J CONllTl<IJCTICN AT NO INCREAeE N COST TO OWNER lb DELlvERY, 5TORAC£ AND MANDLI-I'., f'ROTECT um AND HAlERIALS INDER rnrs SECTION FRIJ'I DAMAGE DJ!sl-l::; CCNSlJ,!JCTICN AND STORN;E PO.. T YIN'rL 01LORIDE (P\IC! FIFE AND ATTl-65 SMALL BE E&FECIALL T Fl'I.OTEClED FR01 ::>IRECT 51.N!.IGIJT. 1.1 5U66TITUTIGl'IS NC DEVIATIONS FRIJ'l 5f1:CFW E12JIA1ENT OR IN&TALLATION PROCEDURES SMALL EE ALLCll.ED Wl"tllO.JT WRITTEN AFmlYAL Cf LANDSCAPE ARClllTECT AND CITY N5F!'CTOR I.& 51B11TTALS A RECORD DRAWl-65, F!iiEPAl<!c CN 6LUELINE PRINT SMQWI-I'., DEYIATICNS FR01 1:110 DOC1.MENTS MADE D~ CCN5TR11CTION AffECT11'11 !'IAN LINE PIPE, CCNOOLLER LOCATICNS, YALYE5 AND SffimER MEADS f<Ecrn:> DRAWi~ SMALL BE DELIVERED TO LANDSCAPE Ai'l'.14l1ECT BEFORE FNAL ACCEFTANCE. B. SIJllMIT FOR l<fYIBII A LIST Cl' ALL l~Tlt1, EG!JlftlENT TO BE UoED. MA'IIFACT\IRER'5 BROOU<ES, MANlENANCE MANIJALS, WARRA'lTEES, AND OPERATICN IN&TJaJCTICNS PRIOR TO START C1' ~ l~ OOARANlEE A r.JARAN1EE ALL um FOR OE 'TEAR FR01 ACCEPTANCE DAlE AGAIN5T DEFECTS IN MAlERIAL EQJIFfMENT AND umMANSMIP. GUARANTEE ~ COYER DAMAGE REPAIR TO ANT PART 11' f'REHl!iES 1¢51JL 111'11 FROM LE.IKS OR DEFECTS IN HAlERIAL, El2llfl'IENT, umMANSMIP TO SATISFACTION Cf LAND5CAPE ~TECT. l:l. A<Cn'TL T MAl:I f<EPAll<S UFCN NOTFICATICN BT LANDSCAPE AR011TECT AND AT NO COST ·o 011NER. PARTl-ffi:lDIJCTS 2J FIFE A A.A5TIC PIPE I. USE PO.. T YINAL 01LORIDE (P'IC! TYPE 112f!-l22f! FIFE OO.E56 OTHERWISE INDICAlED ON Pl.ANS. MAINLNE SMALL Ill' ~ 40 PYC FOR SIZES I-Ill' AND 5'1ALLER CLA55 3e; FOR SIZES l' AND LAFnF<, LAlERAL LNE5 CLASS 31", PYC FOR rn· SIZES, CLASS 200 FOR LAFnl< SIZES, SL~ ~ 40 eENEAnl PEDESTRIAN PA~. SCH. W BENEAT~ YE~IO.UR PAYl-6. 2, FITTl-65, SClfDULE 40 P\IC flTTl-65 3. 5C\.lll:l\'T CEMENT, AS l<ICltlMENDED BY FIFE MWAC!lRR AND Cf Fi<OFEls CCNSISTENCY. HANLNIE CEMENT SMALL l'lE A TWO 51EP (PRIMER! Pl<OGE55 6. l<!cCLAl'tD WAlER 5TSl31Sc FIFE SflALl BE flffl.E COLOR BT ALEr<ILNE OR PACFIC CAL PIPE. 11 RISER A POP UP MEAD&. U5E 501EDULE W P\IC NIPPLES WITh 500 ELL SW~ JONTS PER DETAl5. a RISER ltAPS1 USE GREY 5CMEDULE W P\IC Nlff'\.ES WITH SW~ XlNTS 6ELOIII GRADE PER PET AILS. MEA5URE RISER HEIGHT FROM FINISfl GRADE TO ToP Cf RISER RISER DIAMElER SMALL EE In', EXCEf'T IHRE MEAD INLET 15 LAl<tfR N lll-lK:H CASE RISEfi! WILL MATCH INLEET 51ZE. lNLE55 OfHEJ;WISE NOlED 11, DRAWl-65. C. 5LOFE ltAD&. STM RISERS Cf IMPACT AND GEAR Di<IYEN MEADS 11, 5LOFE5 WIT~ NO , STEEL l<!clNFOfiCI-I::; 6Af<. 51:CIJ!it WITH ADJ115T AaLE 5TAINLE55 51EEL GEARED CL,IJ'lf'. D ~p EMITTER RISERS, USE GREY 5CMEDULE W PVC NIPPlES PER PET AILS. 23 !lFRIN<LER lfADS A PROVIDE 5FRtt+:i.ER MEADS ~ ON l!!RIGATICN LE®V. B. l<ICLANED lll<llER STSTEMS, lt:AD5 5MAll BE Sf'ECIAGAU T MADE FOR RECLAD"IED lll<ITEI< AFFLICATICN WITH flllif'LE COLOR COD~ AND NTa;RAL CMEOC VALVE. 2.4 VAL\/1:S A BALL VAL.YES• F!iOVIDE ~5 PSI RATED VAL\/1:5 !LINE SIZE! FER LEGEND AND DETAILS CN Dli!AWl-65. 6. G!JIOC COJPLER YALYES PROVIDE Fl:R DRAWle AND DELIEYER 10 OJI-ER lll4EN AFFLICA5LE, I. TWO KET5 FOR LOCKED CAP 2. TWO COJ'I..ERS 3. TWO ~ SWIYELS C. AUTG1'1ATIC AND MANiJAL COIOOL YAL YESc F'RDYIDE FER i.E",!'ND AND PET AILS CN DRAWl-65. D. l<ICLAl'IED WAlER ST5TEM5, YAL YE SMALL BE &m;flCALL T MADE FOR RECLAl'IED IIIAlER AFFLICATICN. WIHT lsEVERSED rnREADt6 G:!JIO:: COIJIOI.Ei<S, flllif'LE COLOR COD~ AND DIRT"T" WA lER ' 50<IJBBER' crnTfin Y AL YES. 25 DRIP IRR!r;ATION A TI.Bl-6, I!)_~;• Ill. PO.. TPROF!'LENE ';lf'A'J!IETTI' 1\J6"6. El. EMITTEl<5, FER IRRluATICN LEGl:ND CN DRAWl-65. C. 5TM5' 4' PO.. TFROFELENE EMITTER 5TM5. lb BAOOLOW ~ RE61.11.A TOR A Pl<OYIDE 13AOOLOIII fffYENTER &l4a!N CN LEf:fND Al() NSTALL FER DETAIL Gl'I DRAWl-65. 6. ~lE F!iiE55URE f;EGI.Jl.ATOR AND ALTER DEVICE N A55EMBl. T FER DETAILS AND DRAWl-65. l.7 .IIJTG1'1ATIC CCNTRtlillR A Pl<OYIDE COOROU.ER SM0JN ~ LEGEND CN DRAWW. Pl<OYIDE ALL MO.NT11'11 EGlJIA1ENT AND ~RDWARE i<IGlJli;ED FOR f'EDE&TAL OR WALL MO.NTll't; A5 NDICAlED. a CCNTFl?L WIF&. 24 YOL T 5CLID Ill. AFmJYED FOR DIRECT BURIAL N ~-EILAOC ~ DIRECT LEAD AND 111411E '12 II' ro11Gll @1ND, l.NLES5 OTlffllJl&E NOTED CN DRAWl-65. l.& ornER HA1ERIAL5 A flAC<!=ILL, LOCAL 5CIL, CLEAN, Fi;EE 11' f!JeelSM AND ,ilJCKS OYER 2 1-JCMES DIAMElER a FLA5TIC vALYE 60)(!'~ PLASTIC VAL YE BQ)cf5 WITH LIDS FOR BALL YAL\/1:5 (t,ru.lO! AND AUTG1'1ATIC COIITl<OL VALVES 12 PER BOX MAXM!. FL.ACE b' DEPnl PEA FEA GRAVEL AT BASE Cf OOXE5. FOR 1<!:CLAlt'ED WATER APPI..ICATICN. LIDS SMALL BE F\lliifl.E COLOR C. CMEO:: YAL\/1:Sc F!iOVIDE Sffili>I'.; IN-LINE CHECK VAL 111:5 /LNE SIZE! FER !>.AN AND AS l<!cGlJIRED TO F!iiEYEN: LOW flEAD DRANAGE. D. RECLAIMED IIIAlER 5T51EM5, FroVIDE 5l1E AND W<TROLLER 5IGNAGE AS NDICATED ON DRAW~. E. PROVIDE OTHEf< MATERIALS NOT Sf'EC~ICALL Y DE!CRl!3ED !llJT REG!JIRED FOR A CCtll'I.ETE NSTALLATION AS SELECTED BT CCNNACTOf< 5WJl;CT TO Aff'ROVAL Cf LIWSCAf'E ,Wl!ITECT • PART 3 · EXECUTICN 3.1 S!JffACE cCNDITICNS A YERlfT F~ISM GRADES Al() 51ffACE DRANA!iE WITM LANDSCAFE ARClllTECT AslOf< TO CCl'IMENCEMENT Cf lltJ,,l( El. EXAMINE AREA5 AND CCNDITICNS :.NDER 1114ICH um WILL 6E PE~-CORf;ECT CCNDITl~S DETERIMENTAL TO TIMEL T, FROFER Cl!'IR.ETICN Cf~ DO NOT mxEED LMIL 11,SATISFACTORY CCNDITIONS Ai<!c CORRECTED 31 FIELD MEA5UREMENTS MA-:I NECESSARY MEA5Ul<!:MENTS IN FIELD. EN9JRE PRECISE AT Cf' ITEMS IN ACCORDANCE wm, DESIC,N. 33 LAToJT A LATOUT ~ A5 ACOJRA1EL T A5 FC661ll.E TO DRPJ!lm5 DRPJJI~. ~ CAl<EFJLI. r DRAllN. ARE (£1,ERALL r DIACiRAMMATIC TO EXTENT nlAT SWt,t; XlMS, cmET5 AND ALL FITT!m ARE NOT 5flOJN olTE CCNDITICN5 WILL Nor ALIIIATS PElsMIT LOCATl-6 P!'l1'11, VAL I/ES AND MEADS ~l<f ~ rnlo SITUATICN SflAl.l 6E flROIB!' TO R'MEDIATE ATTENTION Cf LANDSCAFE Al<O+ITECT AND RELOCATION DETEl<l"INED IN JONT ~E-cCN11<ACTOR 15 f<E5f'CN51!lLE fOR f<ELOCAT~ A'IT 11EMS INSTALLED WITHOUT FIR.ST OBTAINl-6 LANDSCAFE ARJ'.:HTEC"'5 AFmJVALAND SMALL F:13'10YE AND RELOCAlE 5IJCM llEMS AT CIIN EXf'EN5E F 5C Dli<IClED er LANDSCAFE Al'lCHllECT. 6. WMEi;E FIPll't; 15 &l4a!N ON DRAWl-65 TO BE ll'OER PAYED Al<IAS BUT .imll'l'J PARALLEL AND ADJACENT TO PlANTl-6 Ai;EAS, TME l~la! 15 TO INSTALL PIPI-I'., N Pl.ANTED Af<EA C MINOR CMA1'11ES IN EC2JIF1'1ENT LCCATIIJ,/ FRIJ'I TMAT 5IOJN Gl'I DRAWi~ SMALL ElE MADE A5 DIRECTED El'f LANDSCAFE .IRC!llTECT AT NO ADDITIONAL COST TO C111ER. PROVIDl!lt', 5IJCM CH/oJll'al: IS ORDERED llEFORE CCffiENCEMENT Cf~ OR Ul:)f<K DIRECTL r ~lED, AND NO ADDITIONAi. HA1Ef<IAL5 ARE f<EGtlRED. H TRENQ.lilt', AND BAOCFILL A Fm'Ol<!'1 ALL EXCAYATICNS AS i<fQJIRED FOR IN!',T AI..LATION Of< 1LOR< ICWJED WER THIS SECTION, m.l.lDl.:.i SMORl.:.i Cf EARTH 6;1N<".S 10 PREYEN1 CAIi!: NS. RE5TORE ALL SU!ifACES, EXl5Tli'l'J INDE~ NSTALLATICNS. ETC. DAM,li;;ED OR OJT AS A f<ESULT Cf EXCAVATICNS TO QRi;INAL CCNDITk:$ ~ HANNER AFml\/1:D BT LANDSCAPE AliOlllECT AT NO ADDITIONAL C05T TO OWNER 13. TRENCME& SflALL l'lE MADE WIDE ENO,.t;J-1 TO MOO A MINM Cf 4 IN BETJ.EEN PARALLEL PIPE LINES AND r.JALL 6E 5UflCIENT DEPTHS TO PROVIDE TME M"11M COYER FRIJ'I FNISH GRADE A5 FOLLO.US, l le IN. MINIMUM COYER 0111:R MANLINE5 TO F!l3'10TE CCNTFl?L VAL\/1:S, 2. ~ IN. MNIMIJ1 COYER 0\/1:R LATERAL LITIE5 TO MEADS, 3. Jo N MINIMI.M COYER INDER YED110JLAR DRIVES, PAl<l<l-6 AREA5, Of< ROADS C. EXCAVAlE FOR IRRluATIGl'l 5T51EM5 BT TRENCHl-6, Wlnl SIDES NEARL T VERTICAL A5 FOSSIBLE. ACCURA lEL T GRADE THE 60TTG1'1 TO PROVIDE ~IF0,!1 BEAR!t6 FOR LINE D. 5flORT SECTIONS Cf TRENCH MAT BE TIMIELED f, IN LAI06CAFE ARCl4l1ECT'S oPNIIJ,/, LINES CAN EE INSTALLED 6AFEL r AND 6AOO'ILL CAN l'lE CG1'1PAC1ED F'RDFER!. T, E. F:13'10\IE OOULDER5 AND OTHER IN1Er;fE~ OBJECTS, BAOCFILL VOIDS F:13'1A"1l1'11 AFlER F:13'10Y AL Cf OBJECTS F. f'ROlECTION Cf PERSc)ILli AND 1-'ROffRI Y, l 6ARRICADE AND OFERAlE ~Ki Lk;!4TS FRIJ'I DUSK TO DAIIN AT OPEN I-IOLE6, TRENOES AND DEm551CNS DCO.JRl-6 A5 PART Cf OOlil< CN Pl<Of'ERIT ADJACENT TO OR WITHIN F'U8LIC ACcES5. l. F'RDTECT 51ro:;TUP-E5, UTILITIES. SIDEWALK PA\/1:MENT AND OTf£R FACILITIES FRG1'1 DAMAGE CAIJ5ED er SETTLEMENT, LATERAL M0\/1:MOO, WASflOIIT, OTHER fWARD5 CREAlED i:\Y ~ 3. DO NOT TREN01 UNDE1' DRIP LNES Cf EXISTl-6 005. G. DO WT 6ACl<FIU 'i;ENCMES llNTIL REl2lli;ED PRESSURE AND LEAl<A(,E TESTS ~YE BEEN PREf{JJ,l'1£j), AND UNTIL SYSTEMS A5 NSTALLED rof()i;N TO SPECIFICATk:$. M. AslOR TO BACKFILLKi, F!l3'10YE ALL 5MEETI-I::; Of< SMORl-6 I. BAOO'ILL !'OR ALL lRENCMES AND EXCAVATIONS SMALL 6E ca1PACTED TO 'll!)\ DENSITY. J, BACKFILL TO LEVEL Cf APJACNET ELEvATICNS, ALLOIIII~ FOR eETT\.Ki AND CG1'1PACTICN. 35 NSTALLATICN Cf PIPlf-6 A PIFli'l'J DEFrn, INSTALL PIPli'l'J UJT~ AT LEAST THE FOLLOWl.:.i DEPTH Cf COYER- P\IC MAINLINE-IS INCHES f'YC LATERAL· U INCHES FOL TPROPELENE 7J6li'l'J-3 INO-ES !l. P!'IJ,i, i.NDER PAYEMENT, SLEEVE "'IPN'.i UNDER PAYED Af<EAS AS INDICATED CN DRAW!-65. EXTEND SLEEV~ n• l'lETCW EIX£ Cf PA~. CUR!l5, WALL5 ETC. C. INSFECTICN Cf MATERIAL& CAFiE!'JLL T N5F!'CT FIFE~ FITTW,S BEFORE l5TALLATICN. F!i3'10YKi ALL DIRT, SCALE AND 61»1.5, i<!cAMti'.; AS .EGlJIRED. !Ne! ALL FIFE Wlnl MARKli'l'J5 IIF FOR vl$JAL IN5F!'CTICN. D. PLA5T'C (f'\IC) PIFE I. EXE!il::l5E CAi<E ~ MANDLltG, LOADll'l'J, illOAD~ ~ 5TCl<lr<, PLA5TIC PIPE AND FITTlK,!I. AJ 6TORE INDER COYER FRG1'1 Dll<ICT 5LNl.lc,I/I UNTIL l<IADT TO NSTALL BJ TRAN5f'ORT CNL r CN YE~IQ.E WiTI-' E£D L01'11 EN0.6H TO ALLOW PIPE TO LAT KAT, TO AVOID iNDUE !'lElDll't; AND CCNCENTRATED EXlE~ LOAD. 2. REPAIR DENTED AND D;IJ"IAGED PIPE BT CUTT~ OUL r AND Dl5CA1,Pllt; DENTED OR D;1MAC£D &ECTICNS, i<EJOININ'..i WITH A CG\IFl.lilt',_ 3. IN JOINI-I::;, USE CNL r 5PECFIED fO..YENT MA-:I JOINTS IN ACCORDANCE WITH MIWJFACMER RECG1'1MENDATIONS. Pff AND FITT~ SMALL 6E T~ T CLEAIIED Cf DIRT, DJST. MOl5Tul<f BEFORE APR. rl-6 5CL 111:1\'T. CLEAN af EXCE55 5CL 111:1\'T. ALLOW 5CL 111:1\'T ~DS AT _EA5T ~ MNU1E5 SET IIF TIME 111:FORE MOYll'l'J OR HANDLl-6 AND 24 fWlw Dli'l'J TIME BEFORE FILLl-6 Wlnl IIAlER 4 fJ-IAl<E LINES A<l'.1'I SIDE TO i>DE IN TRENCH TO ALLOIII FOR EXFANSICN AND cCNlT<ACTICN. S. FOR PLASTIC TO METAL CCNJ.ECTICNS± AJ um METAL ~TICNS =iRST. BJ USE NCN HARDENli'l'J Pff DOF'E 11, ThREADED A.ASTie iO METAL Cru-lECTICNS. CJ USE CNL Y A Lk;\4T ll.lsENQJ PRE55URE. DJ USE JONT ~ CN GALVANIZED IRON FITTl-65. E. Plll'., Of< CAP ALL OPENNGS UPCN LfNE IN!',TALLATICN TO F!iiEYENT ENTRANCE Cf MA1ERAL5 rnAT M~T 0651f<IJCT PIPE. LEAVE N PLACE LMIL REMOVAL 15 NECESSARY !'OR CCMF\.ETICN Clf-INSTALLATICN. F. T~ T FLIISM ALL LfNES, ~ flTD~TATIC lESTl-6 PE1' PAi.AsRAPM 6ELOIII. 3.& NSTALLATICN Cf EGlJIF'EMENT A POP llP oA<A'f MEADS I. INSTALL lll4E'<!' INDICAlED CN DRAWW IN ACCORDANCE WITH DETAILS AND MANU'ACTIJRER l<!ccct1t'ENDATION A5 AFmJYED B" LANDSCAPE Al'lCHllECT. l. LOCATE POP llP 3' FRG1'1 PEDE5TRIA'I PA~. r• FROM AUTG1'100ILE TRA'flC WITHOUT CllRB&, h' FRG1'1 AUTO. TRA'flC WIT• CURll5 AND 6' FR01 ALL BUILDl'6 AND WALL FOOTl-65 lNLE55 N01ED ornERWl&E. 51:1 MEADS fLUSM 10 ADJACENT PAYli'l'J Of< IJR4DE faEYATICN. 3. UPCN LNE 1E5TI~ Cl1'11'l.ETICN. mlPLElE A75EMBL T, AD.AIST 51'ROOER MEADS FOR Fi<OFEls Dl5TRl6JTICN. 13. RISER flEADS l !NeTALL IN Pl.ANT~ Al<!:A5 WMEl<f INDICATED ON Dli!AWl-65. l. LOCATE RISER MEADS NOT IIITHIN 11!1 FEET Cf PEDESTRiAN PAYR,i',, AND ~• FR01 IIIUTG1'1061LE TRAlflC Wl"tllO.JT CURll5. 6' FRIJ'I AUTO. TR/,;!'IC UJTM aJR65 AND r,• FROM ALL 61.Jll.Dll't; AND WALL FOOTli'l'.iS IM.E55 NOlED OTl-tRWISE. SET 5l-1l'!l6 MEADS Ekll-filEN (le'! INCHES A60YE FNISM GRADE lllES5 NOTED OTlffllJl&E !SEE PET AILS!. 3. UPCN LINE TEST~ W1FL8ICN, CG1'1R.E1E A55EM6L T, ADJ115T 5PRN<LER MEADS FOR FROFER Dl5TRIWTICN. C. VALYESc INSTALL BALL YAL\/1:5 AND GlJIO:: CM.ER VAL\/1:S FER DRAlll1'115. f'RO\IIDE l:'lALl. VAL\/1:5 TO SEFARATE GlJIOC COJ'I..ERS AND CCNTOL VAL Ill: CLll5TER5 FRG1'1 MAINLINE. D CCNTROL VAL\/1:&. NSTALL WMEl<!c 5fJoUN CN DRPJJI~. LOCATl-6 N CLll51El<5 N f'I..ANII-I::; AREAS lll4ERE PRACTICAL PLACE NO CLOSER TM.!N ~• AND PARALLEL TO lllALK EDGES, 6UllDm5 AND WALL5. MruiE ll VALVE 80lcf5 WITH TOPS SET FLU&H TO GRADE. SEPARATE Q.1151ER5 FRCt' MAINLNE Wlnl 6ALL YALYE. 5TREET 5URFACE --- ~),#'~/"Jfd/"J'l"t'7J" POTAEILE SERYICE LINE --~ 3.5 FEET (SEE IMFROYIEMENT DRAW~! ll' MINll1JM l<IG!JIRED YIERTICAL SEFARATICN . J RECLAIMED IIIATER 11,RIC.ATION MAINLNE W/ SLEEVE NOTE, ALL 1'!:CLAIMED IIIATER IRRlr.ATION PIFE AN[) SUEEYES &MALL 6E l"Ui<F!..E AND LA6LED A5 l',ffCFIED IN, '&TANDARD l',ffCflCATIONS FOR PRIVATE IRRlr.ATION 5'f5TEM5' 'CARL5BAD RECLAMATION iaJLE5 AND REGULA Tlal5 FOR CON&Tl<UCTICN 11' i<ICLAIMED WATER MAIN&' OCTOl'lER l'ffl CD POT ABLE MAINLINE CROSSING &IDEUIALK ----, CURB--~ APFROX.8' ~-METER BOX UII METER 24' POT ABLE SERVICE L"1E ll' M1111JM • ~ ........ w ''""' "'"" """ • ~ RECLAIMED WATER IRRl6ATION MAINLINE WI 5LEE\IE NOTE, VERTICAL CLEARMICE OF 12' MIIIIMUM 15 MANDATORY 11.1-1EN CR05&IN6 FATH OF A POTABLE WATER LINE. IN5TALLATION OF RECLAIMED IIJATER IRRl6ATIO< MAIIILINE 24' FROM FACE OF SIDEWALK WILL PROVIDE THE NECESSAR'f IIZ!' 1--IORTIZONT.AL CLEARANCE FR0'1 POTABLE MAINLINE IN 5Tisl:ET. Q) POT ABLE SERVICE LINE CROSSING F 6AC.'(11_QW F!iiEYENlER IN&TALL lllEf<E WICAlED CN Df<AWl-65 AND IN AafflJANCE WITH ALL FERIENANT CODES, f<EGIJLATICNS, AND Ml!FACT\IRER'ii REOO'T'ENDATICNS A5 AFFROYED 6T TME LANDSCAPE AR01l1ECT ~ CAR!.5BAD i"WICIPAL WAlER Dlol!IJCT. G. AUTG1'1A TIC CCNmOLLER I. NSTALL A5 ~ CN DRPJJll-65, OO.E55 OTl-tRWISE DIRECTED BT LANDSCAPE ARCllllECT, l Ca-lNECT !¢MOTE crnTfin VALVES TO a:NTROLLER IN &EGIIJENCE GORRE5PCNDl1'1110 THAT NDICATED 11, DRPJJll-65. lll4ERE TWO OR MOf<E YALYES MAYE SAME Nltl6ER. WIRE TCX£TMER AT CCNTFl?illR DO NOT GROlf' DRIP AND oA,AT MEAD& ON &AME STATICN. 3. ELECTRICAi. 5IIPPL r TO PONT Cf ca-NECTION SMALL BE er OTME"5. ffiJYIDE '~ii:[) Wll<!c' oFLICE INTO EX15T~ J~CT1t1, 60X NEAR W<IROLLER LOCATICN. µ_ AUTCMATIC t.CW1RGc WIR!t6, L NST ALL CONTROL WIRES, l~GATICN MANS AND LAJE1'AL5 N CO'l'ION TRENCHES 1114ENEYER P055l!3LE. l. NSTALL CCNIROLWIRE5 AT LEA5T 18' ElELOlllflNISfl GRADE AND LAT TO SIDE Cft16.INLINE WHERE FC6611ll.E. WIRES SMALL l'lE A MINl!ffl I' FR01 ANT PIPE OR FITTl!lt', EXCEPT AT lE,-l-:INAL FONTS. Pl<OYIDE LOOPED SLACK AT vAL '1!'5 AND eNAKE WIRE& N TRENCH TO ALLOW FOR COORACTICN Cf WIRE. TIE Wll<f IN 61.NDLES AT IIZ!' INlERYALS Wlnl PLA5TIC ELECTRICAL TAPE 3. WIRE 5PIXE5 WILL 6E ALLOIIIED CNL T CN ~ MORE nlAN !;00 !!'ET. CRIMP IIIRES TCX£TMER wrrn APFR.OYED WII<!: ro+IECTOf< AND 5EAL CCH,JECTION PLACE N A60YE GRADE Pili OOX PER 5.6N DIEW REC!IONAL ST ANDA~ DRAWll'l'J I-IE,, 4. F'RDYIDE 51:PARAlE SLEEv~ FR01 IRRluATlt1, LNES FOR COOl<OL Wli<I$ BENEAnl PAVl-6. IIIALLS, ETC. 5. WIRE5 SflALL 6E PLACE IN GRE"f SCI-EDULE !li!I P\IC ELECTRICAL 5LEEYE FRIJ'l l!I' 6ELOW GRADE TO ::or,m;QLER AT W<TROLLER LOCATICN. 6. Pl<OYIDE IN EXTRA WIRE FFn1 CCNTFl?LLER TO RJRTMEST VALYE IN EACH DIRECTION A<l'.1'I EACH CCN1<0LLER. 31 lESTl-6 AND INSPECTICN A DO NOT ALLOIII OR CAU5E ANT um Cf TMIS SECTICN TO 6E COVERED OR ENCLOSED lNTIL fl MAS 6EEN HST ALLED. TESTED. AFmJYED BT LANDSCAFE ARCllllECT AND CITY N&FECTOR. REGU:ST INSFECTICNS AT LEAST FORTT-Ek>HT (48! f!oJl<S N POVANCE HOUl<5 ~ ADYANCE Cf lESTI-I,_ 6. flllSH PIPE 8EFORE 6AOCFILL~ MAINLINE, Wlrn coorm VAL 111:5 A.ACED BUT BEFORE LATERAL LN:S Alac CCH,JEC1ED, CCMPLE1EL T R.l5H AND TEST MANLNE. L !¢PAIR LEA1(!l. 2. FLU5H oJT EACH e!:CTICN 11' LATERAL PIPE 8EFORE 5PRINKLER MEAD& ARE ATTA01ED. C. 1ESTl6 I. MM NECE55ART f'ROVISIGW TO T~ r lll.EED LNE Cf All< AND DE6RIS. l. A'1ER YALYE6 AA\/1: EIEEN IN&TALLED. ~ ~DED PlASTIC JOINTS ~Ill: CURED !'OR 24 llCIIRi, lEST MA"1 WATER LNES l'OR LEAKS AT F!iiE5eUf.l' Cf ll!:> PSI FOR PEROD Cf 24 llCIIRi 111TH COIJIOI.~ E){f05EJ) AND PIPE SECTIONS CENlERLOAPED WIT~ 5UflCIENT ElACKFILL TO PREYENT ARQ,1-6 OR 5LIPPKi UNDER "RE551ft. LAlERAL LINES SflALL EE 1E51ED, Wlnl ~5Ei<S GAFFED, FOR TWO fWl<S UNDER NOf;HAL STATIC PRE55URE. 3. F'RDYIDE REG:!JIRED 1E5Tli'l'J EG!JIF!'IENT AND FE~L 4 REPAIR LEAKS, RETEST lNTIL ACCEPT ANGE BY LANDSCAPE ~ITECT AND CITY NSPECTOR. D. ANAL NSPECTION, CLEAN, AP.1151, BALANCE ALL STS'IE'1&. 111:R~, I. ~ADS Af<l: Fm'l:R!. T ADJ.15TED FOR RADIJ5 AND ARC Cf C0\/1:R,!l,E 2. !NeTALLED SYSTEM 15 utll<l<ABLE, CLEAN, EfflCIENT. E. i;ECLAD"IED IIIAlER ST51EMS, 9<1JYIDE CROSS Cl»IECTION, COYERAl',E, DrnER TESTN'.i l<IG!Jll<ID B'f MEALnl DEPARTMENT OR IIIATER DllTRICT (SEE f<ECl.AIMED NOTES, &MEET L-11 3B RECLAlt'ED WAlER St;N.!,6E IN&TALL A5 5flCIIN Gl'I DRAWn-r.e OR f;EGIJIRED BT 1-iEAL TH DEPARTMENT Of< WAlER DISTRICT. 3.9 NSTlilJCTICNS A ATTACI< TYF'EIL!<ITTEN LEGEND NSIDE EACM CCNTOLLER DOOR, STATl)I'.; AREA5 COYEf<ED BT EACH VALVE. f'RO\IIDE REDUCED. LAMNAlED. COLOR CODED t1'.P Cf AREA l!IR~lED er CCNTOLLER. a AFTER 5T5TEM MS BEEM CCMPLElED, 1ES1ED, INSPECTED AND A"'AsOYED, N5TR11CT CIINER OR MANlENA'tt FEl<!',CNNEL N Ol'ERATlt1, ~ MAINlENANCE Cf 5TS1EM 3l'/ MAINlEl¼NCE MAMAIN SYSTEM FOR PERIOD NDICAlED N l!!Rlr;ATICN NOTES, OR LE1'11nl Cf PlANTl-6 MAl1'11ENANCE PERIOD, 11141Ci-lEYER lo 6'£A1ER END Cf 51:CTICN &' R01W Fl.ASTie YAL\/1' OOX Wt PURFLE CCM:i< . ~ flNISM CiRADE - 11111 1111 BALL VAL VE IIATH LNIONS (&<&! ,,: 1111111111 YAL YE BOX EXTENSlo,15 I: is, 11111-11 LENG rn A5 Rl:G!JIRED 11111 PYC MAINL"1E 11111 0 ° $a 0 i;;;;;; i;;;;;; 314' DIA c,RA\IEL. MIN. 12' DEEP lllll 1°111'0 olct)III =,,,,, 11111 11111 -1-I~.---11111 BALL VALVE ,-------PAYE!'ENT, WALL, FENCE OR al1'iB ,---SEE &fEC5, FOR DrnER Olf5ET l<fl2JIREMENT5 3' ~-Hl&4 POP IIF !lfl<AT MEAD, FLU&H W/ c;f<AIJE FNISMGRADE -+---E= ...---1-+~lflt--In' -STREET ELL CMIPTlCFIPT! 1-1.....,_....,..;L,----a~-12 , In' f'YC SCH al!! NIPPLE ,.----In' -STREET ELL (MIPTlCFIPTJ ~-1n• -STREET ELL (l'!IPf,FIPT! FVCLATERAL ~--6CH al!! FVC &<&<T TEE OR ELL NOlE, ALL 511ll>I'.; JOINT CCMPONEN!o SHALL EG!JAL MEAD INLET SIZE NOTE, USE OOTTt.l'I INLET a-I MEADS WITH MEl,!',RAL GMEOC VAL YE N'TS • (E) POP-UP SHRUB SPRAY NTS ,.-------I!) FT. MIN. DISTPIIICJ: REG!JIRED FRa"I PEDESTRIA'-1 USE A1'!:A (, • (~ SEE 5F'ECIFICATION5 ~ Sflfill6 MEAD OR BUOOLER rrl'--------t----,+,' PAVl>r,, WALL, Fan OR CURB ~v--STAINLE55 STEEL SCREW CLAMP ,,--50< 81!1 FVC RISER. SIZE FER ~AD INLET Ht---'3 REBAR. 30' LOO ·~==ffl"'~ .,,,, ------=I== i1111 1111 ~II II IIIII ---STREET ELL (M x Fl r---STREET ELL (1'! x F J ,.----50< 41!1 FVC TEE OR ELL /5 x 5 x F J JI---PYC LATERAL LINE • @SHRUB RISER "' ' 1'-6' WARNING REc2AMED WATER 00 NOT ORNK '4' RADIUS 16' X 18' X '4' EXT. A-C FIR PL TIUOOD Jill& ALlMINUM, Af! AB5 F\.ASTIC OR STICK-ON VN'fL 511',NS PRIME AND PAINT wrrn 2 COATS F\1"1'1-E EXT. PAINT. DETAIL 1111 Ill.ACK LETTER5. !'RITZ GlUADRATA' FCNT ,~--In' BOF<DER. BLACK ,----tt----~ DRILL FIFE I 511',N, SEQJRI: WITH ~YET OR 1 A"1FER PROCf OOL T ,--2' (;;lj_y_ STE~L PO&T. INSTALL PO&T FLUSM WITM "OP Cf SIGN. TOP OF SIGN 10 6E 4' AOOYE f~ISM GRADE. FQOTl>r,, Dli; ~• X 8' DIA MCLE AND SECURE 18' Cf POST N CCNCRETE. NOTE CON1'1ACTOR TO PROVIDE 51GN5 A5 INDICATED al KET MAP, LOCATE IN FIELD WITM LANDSCAPE ARCHITECT RECLAIMED WATER SIGN NT5 NOTE· ALL Wlfi!~ SHALL !lE f'Efi! LOCAL CODE A"lD N.E.C. -ca;NECT IIIRIN6 WITH 'ffN TIT£' WO.IERf'lsed-t.Oi'NECTOR5 ,------CONTI-l?LLER PER LE®'ID. Mo.M TO ENCLOOJRE WALL PER MANUFACT\J1'£R'5 SFECIFICATla! -...---i"'.=r=-=_:f~"""ll ,.-----Jl.NCTlal 60XE5 ..,. "' QI!) V. Fo.il:R A"lD uRCIJND 10 ~f) Y. POJ.l'R sum T PVC CONDUIT BASE PER OOX l"1A'llf ACT\Mi< FINISH (;RADE CONCl'ETE 61..AB, 4' DEPTH DIRECT BURIAL WIRE TO VAL\/1:5 2' DIA FVC W 6CH W 511.EEF Ell @ BOX MOUNTED CONTROLLER NOTE-INSTALL F'Ef< CMlllJ S1P. Dil.6. 'IIJ.21!) ~-----6RA55 ELLS I NIPPLES, TTPICAL ~--BAOOLOJJ PREVENTER PER LE®'ID ,...._...,,_ElRA&S ELLS C NIPPLES ¢ot+---BRAS5 UNION NT& FINISH GRADE ~-CCffiR 5UPPL T LINE FRa"I METER 12' X C' X ll' CONCRElE NOTE-NO CLOSE NIPPLES &MALL EE ALLOl!fD @ BACKFLOW PREVENTER NTS ,-------FINl&I< GIAADE ~--FVC LATERAL TO HEADS ~--5Ci-l 44!1 FVC MALE ADAFTEI< ~-14'xl~' PlASTIC VALl't BOX WITH RJRPLE COVER REMOTE CONOOL VAL VE ,~=t9~"f:.:::~ill![~~IIIATER FROCf Wl!iE CONNECTIONS ~ 111110 In' WIRE EXPANSION COIL5 ~---,..-==1---6CH 81!1 FVC LNIO>J ~----11-tt1tcc"""""6CH !li!I f'\IC NIPPLE Lff~ 6CH 4e FVC WP ELL 314' GIRAYEL. MIN 12' DEPl'H H±i~t--5Ci-l 81!1 f'\IC NIPPLE CCffia-1 UJRE ,~TT:-:-n:r'-::'tri~~ir:::'.....CONTROL WIRE h'--"""iiii'---FVC MAINLINE -~--~ 41!1 FVC TEE OR ELL(5><5><FIPT! @ AUTOMATIC CONTROL VALVE NOTE, ii'fCLAIMED QJIOC COIJPLER SMALL 6E DIFFERENT AND 51-IALL NOT BE ~LE WITH POT ABLE WATER FITTl-l::;5. NTS ,-----6 IN. DIPl'IETER PLASTIC VALVE 60X C RlRFI.E COVER ~--------lxlxl4' ROW STAKE ,..--------QUICK COUPLER YAl\/1: r---FNISl-i GIRADE ™;;;ij---t---I' 5Ci-l 40 PYC Wd ELL /FIPT><flFTJ q..f,!~-i-------I' Wd STREET ELL (MIPTxFIFT! Q)=--FVC MAINLINE 6CH 41!1 FVC TEE /5x5x I' 5! '----1~--I' &CM W FVC NIPPLES APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. lTTl£ REVIEWED BY: INSPECTOR N Steven M Ahles LANDSCAPE ARCl--!ITECT P.O. Box 682 Cardiff, California 92007 CAt 25J8 NW441 Cl) z <( _J n.. f--z w ~ w > 0 a: n.. '.2 w n.. <( 0 Cl) 0 z <( _J ""'-632.0288 --76IW2.0289 a: w f--z w o<C I-OZ a: a: <Co WLL CIJ _J w<C a:O -LOO □ CO <( <( mm I-~~ 0 a: a: <( <( _JOO SET ISSUED SHE~T R~VISIONS 10 MAY 98 DATE "I. AN CHECK 15 JUL. 98 "LAN CHECK 2 12 AUG 98 DRAWN BY: srra CHECKED BY: l'ROJE C • NO: SHicf-1 TIii~: SCALE SHEET NO. L-9 OF "AS BUILT" DATE DATE -------------t-~--_-_---:._-_-_-~~~---+--~l~~ff l~I _c_1~_N_~-~-£-~-~-L_s_~_A_D~ll~E:ral DATE NITlAL LAND. ARCH. ------------------+----+--__, __ --+-_ ____, REVISION DESCRIPTION DATE NITlAL DATE INITlAL arf APPAOVAL cmER APPAOVAL IRRIGATION DETAILS 4 5PEC5: LOT 65 CAAl.56AD ~Am-! CENTEFi1 C.M.IUD. J06 NO. '38-216 SHEET -D