Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DWG 429-3L; PDP 00-01G; EWPCF-OP'S & MAINT FACILITIES; 01-11
I ; t N t N - I I I I I I RIVERSIDE COUNTY -""""" ......... -- VAJJ.Sf CINflllt DIEGO ... -MEXICO LOCATION MAP NO SCALE ENCINA WATER POLLUTION CONTROL FACILITY SOUTH VICINITY MAP NO SCALE " I ! ' ! ' I I I I I I : . .. . . ·- ' . • . . RECYCLED WATER SYSTEM (P'RIVATE) < OPERATIONS & MAINTENANCE FACILITIES ,.,....., -- ·-Wl!LL COUNTY MOUNT ~ I I I I ! ~ % :::> 0 Q ~ 0: l,J Q. :::E - RECYCLED WATER NOTES 1. ALL 'MlRK SHALL BE DONE IN ACCORDANCE WITH THE CARLSBAD MUNICIPAL WATER DISTRICT'S "CARLSBAD RECLAIMATION RULES & REGULATIONS FORCONSTRUCTION OF RECYCLED WATER MAINS" DATED OCTOBER, 1993, 2. DRINKING FOUNTAINS SHALL BE PROTECTED FROM SPRAY OF RECYCLED WATER BEST MANAGEMENT PRACTICES SHALL BE USED TO MINIMIZE RECYCLED WATER ENCROACHMENT ON PUBLIC FACILITIES SUCH AS PICNIC TABLES, BBO'S, PLAYGROUNDS, SAND LOTS, ETC. 3. BEST MANAGEMENT PRACTICES SHALL BE USED TO ELIMINATE OR CONTROL TO THE BEST EXTENT POSSIBLE, PONDING. RUN-OFF, OVER SPRAY AND MISTING. 4. HOSE BIBS ARE STRICTI. Y PROHIBITED. 5. ON-SITE CROSS-CONNECTIONS BETWEEN RECYCLED WATER LINES AND POTABLE WATER LINES IS STRICTLY PROHIBITED. 6. NO SUBST1TUTION OF PIPE MATERIALS WILL BE ALLOWED WITHOUT PRIOR APPROVAL OF THE CITY OF CARLSBAD MUNICIPAL WATER DISTRICT. 7. ALL ON SITE PIPES SHALL HAVE WARNING TAPE PER CARI.SBAD MUNICIPAL WATER DISTRICT'S RULES AND REGULATIONS. 8." THE IRRIGATION SYSTEMS SHALL RUN BETWEEN THE HOURS OF 10:00 P.M.AND 6:00 A.M. THE FOLLOWING MORNING (SPOT IRRIGATION COULD BE DON EAT A DIFFERENT TIME WITH QUALIFIED SUPERVISORY PERSONNEL). 9. PROVIDE A MINIMUM OF AT LEAST 18 INCHES OF COVER OVER ALL 'MRING AND PIPING. 10. NON-OESIGNATED USE AREAS SHALL BE PROTECTED FROM CONTACT FROM RECYCLED WATER. WHETHER BY 'MNDBLOWN SPRAY OR BY DIRECT APPLICATION THROUGH IRRIGATION OR OTHER USE. LACK OF PROTECTION, WHETHER BY DESIGN, CONSTRUCTION PRACTICE OR SYSTEM OPERATION, IS STRICTLY PROHIBITED. 11. IRRIGATION HEADS SHALL BE RELOCATED OR ADJUSTED TO PREVENT OVER-SPRAYING ON SIDEWALKS, STREETS AND NON-DESIGNATED USE AREAS. 12. RECYCLED WATER QUICK COUPLING VALVES SHALL l!E OF A TYPE DESIGNED FOR USE ON RECYCLED WATER DISTRIBUTION SYSTEMS (SPIKES NOT INTERCHANGABLE WITH POTABLE WATER QUICK COUPLER SPIKES) PER CARLSBAD MUNICIPAL WATER DISTRICT'S RULES AND REGULATIONS. 13. METERS SHALL BE SIZED BV THE CITY OF CARLSBAD MUNICl'AL WATER DISTRICT. 14. ALL IRRIGATION PIPE !IHA1.L BE STENCILED WITH THE WARNING, "NON-POTABLE OR RECYCLED WATER", COLOR.CODED (PURPLE) ANO LAID WITH WARNING TAPE AND STENCILING ORIENTED TOWARD THE TOP OF THE TRENCH PER THE CARLSBAD MUNICIPAL WATER DISTRICT'S RULES AND REClULATIONS. 15. ALL POTABLE WATER AND RECYCLED WATER PIPING SHALL BE INSTALLED WITH THE STENCILING ORIENTED TOWARD THE TOP OF THE TRENCH. 16. WHEN POTABLE WATER LINE AND RECYCLED WATER LINE CROSS, THE RECYCLED LINE SHALL BE INSTALLED WITHIN A PROTECTIVE SLEEVE. THE SLEEVE SHALL EXTEND 10 FEET FROM EACH SIDE, FROM THE CENTER LINE OF POTABLE LINE, FOR A TOTAL OF 20 FEET. 17. A 10 FOOT HORIZONTAL SEPARATION BETWEEN POTABLE WATER ANO RECYCLED WATER MAINS MUST BE MAINTAINED AT ALL TIMES. THE POTABLE LINE MUST BE INSTALLED ABOVE THE RECYCLED IJl,E. 18. A MINtMUM OF 12 INCHES OF VERTICAL SEPARATION BETWEEN uTILmES MUST BE MAINTAINED AT ALL TIMES. ' 19.' THE REQUIRED CROSS-CONNECTION SHUTDOWN TEST SHALL BE DONE BY THE CARLSBAD MUNICIPAL WATER DISTRICT AND THE SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEAL TH. QUICK COUPLING VALVES USED IN RECYCLED WATER SYSTEMS SHALL CONFORM TO THE FOLLOWING: 20. RECYCLED WATER: QUICK COUPLING VALVES USED IN RECYCLED WATER SYSTEMS SHALi.HAVE ACME TYPE THREADS AND PURPLE COLORED LOCKING COVERS PERMANENTLY ATTACHED TO THE VAL VE. QUICK COUPLING VALVES SHALL BE NELSON NO. 7645, HUNTER NO. HV100MIL•NP OR APPROVED EQUAL. (SPIKES NOT INTERCHANGABLE WITH POT ABLE WATER QUICK COUPLER SPIKES) 21. THE REQUIRED CROSS-CONNECTION INSPECTION SHALL BE DONE BY EITHER THE CARLSBAD MUNICIPAL WATER DISTRICT ANO/OR SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEAL TH. COPIES OF INSPECTION REPORTS 'MLL BE FORWARDED TO THE NON~NSPECTING PARTY. 22. • DEVELOPER SHALL SHOW 1lE LOCATIONS OF R.C. SIGNS "00 NOT DRINK" ON THESE PLANS. 23.' AN ON-SITE USER/SUPERVISOR SHALL BE DESIGNATED IN WRITING. THIS INOMOUAL SHALL BE FAMILIAR WITH PLUMBING SYSTEM WITHIN THE PROPERTY, WITH THE BASIC CONCEPTS OF BACKFLOW/CROSS CONNECTION PROTECTION ANO THE SPECIFIC REQUIREMENTS OF A RECYCLED WATER SYSTEM. COPIES OF THE DESIGNATION WITH CONTACT PHONE NUMBERS SHALL BE PROVIDED TO THE SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL 24. 25. 2e. • • HEAL TH ANO THE CARLSBAD MUNICIPAL WATER DISTRICT. IN CASE OF EMERGENCY CONTACT JOHN JARDIN AT (760) 438-31141 AFTER HOURS CONTACT JOHN JARDIN AT (7811) 438-3941 SHOW ALL PUBLIC AND PRIVATE POTABLE WATER MAINS ON IMPROVEMENT PLANS. ON RECYCLED WATER SYSTEMS, ALL APPURTENANCES (SPRINKLER HEADS, VAL VE BOXES, ETC.) SHALL BE COLOR CODED PURPLE PER AWWA GUIDalNES AND SECTION 116815 OF THE CALIFORNIA HEAL TH AND SAFTEY CODE. THERE SHALL BE A PHYSICAL SEPARATION BETWEEN AOJACENT AREAS IRRIGA TEO WITH RECYCLED WATER ANO POTABLE WATER. SEPARATION SHALL BE PROVIDED BY CONCRETE MOW STRIPS, CHAIN LINK FENCES, OR OTHER MEANS AS APPROVED BY THE WATER DISTRICT AND D.E.H. ITEMS 8,19 & 23 SHALL BE REQUIRED JUST PRIOR TO THE ACTUAL USE OF RECYCLED WATER. ITEM 22 THE SIGNAGE PLAN SHALL BE A PART OF THIS LP. BUT THE ACTUAL SIGNS AND TAGS WR.L BE INSTALLED JUST PRIOR TO ACTUAL USE OF RECYCLED WATER. I ' INSPECTION PROCEDURES , . 2. 3. CITY CONSTRUCTION INSPECTION SHALL INCLUDE: A. LOCATION OF PIPE LINES 8. TRENCH DEPTHS C. REQUIRED SEPARATION (HORIZONTALLY AND VERTICALLY) D. PIPE IDENTIFICATION E. POINTS-OF-CONNECTION (POC'S) F. LOCATION AND IDENTIFICATION OF SPRINKLER HEADS G. WARNING SIGNS AT THE SITE AND ON THE TRUCKS HAULING RECYCLED WATER (IF RECYCLED WATER IS USED FOR CONSTRUCTION). AN APPROVEO LETTER REGARDING THE INSPECTION OF THE PROJECT SHALL BE OBTAINED FROM THE CITY AND THE DISTRICT, AND BE FORWARDED TO THE SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH PRIOR TO FINAL INSPECTION APPROVAL. DISTRICT FINAL INSPECTION SHALL INCLUDE: A. COVERAGE TESTS, AFTER COMPLETION OF THE SPRINKLER SYSTEM, TO DETERMINE THE ADEQUACY OF COVERAGE ON THE APPROVED USE AREA ANO PROTECTION OF AREAS NOT APPROVED FOR RECEIVING RECYCLED WATER. B. WARNING SIGNS AND LABELS. C. QUICK COUPI.ING VALVES. D. ALL ASPECTS OF THE IRRIGATION CONDITIONS INCLUDING WINDBLOWN SPRAY, RUNOFF ANO PONDING. E. REQUIRED PROTECTION OF ALL RESIDENTIAL AREAS. F. REQUIRED PltOTECTION OF WELLS, STREAMS, RESERVOIRS, ETC. G. CROSS.CONNECTION. ANNUAL INSPECTION SHALL INCLUDE: A COMPLETE INSPECTION WHICH SHOULD COVER PARTS "A", "II" AND "G' OF THE DISTRICT FINAL INSPECTION. \ ~ KEYMAP SCALE: 1 "=200' 100 200 liiiiiiiiiiil GRAPHIC SCALE IN FEET: 1 "=200'-0" CARLSBAD MUNICIPAL WATER DISTRICT 9-,3~Q5 LLIA E. PLUMBE R. .E. 28i.76 DATE DEPUTY CITY ENGINEER EXP. COUNTY OF SAN DIEGO DEPARTMENT OF ENVIRONMENTAL HEALTH ~ -Z<:::.------~5 DATE I I I I SIGNAGE NOTES THE FOLLOWING GUIDELINES FOR THE USE OF RECLAIMEO WATE!t ARE TO BE P'ERMANENTL Y POSTED INSIDE THE COOR OF EACH CONTROLLER Wl-ERE THEY ARE EASILY VISIBLE. PLACE ON A 8-1/2" X 11• SIZED SIGN. COLOR: WHITE BACKGROUND WITH PURPLE LmlNG. I. GUIDELINES FOR RECYCLED WATER USE 1. IRRIGATE BETWEEN THE HOURS OF 10:00 PM ANO 8:00 AM ONLY. WATERING OUTSIDE THE TIME FRAME MUST BE CONE MANUALLY WITH QUALIFIED SUPERVISORY PERSONNa ON-SITE. NO SYSTEM SHALL AT ANY TIME BE LEFT UNATTENDED DURING USE OUTSIDE THE NORMAL SCHEDULE. 2. IRRIGATE IN A MANNER THAT WILL MINIM~ RUN-Ol'F, POOLING, ANO PONDING. THE APPLICATION RATE SHALL NOT EXCEED THE INFILTRA T10N RATE OF THE SOIL. TIMERS MUST BE ADJUSTED SO AS TO BE COMPAT1BLE WITH THE LOWEST SOil INFILTRATION RATE PRESENT. THIS PROCEDURE MAY BE FACILITATED BY THE EFFICIENT SCHEDULING OF THE AUTOMATIC CONTROL CLOCKS, ~.E. EMPLOYING THE REPEAT FUNCTION TO BREAK UP THE TOTAL IRRIGATION TIME INTO CYCLES THAT Will PROMOTE MAXIMUM SOIL ABSORBTION. 3. ADJUST SPRAY HEADS TO alMINATE OVERSPRAY ONTO AREAS NOT UNDER 1lE CONTROL OF THE CUSTOMER. FOR EXAMPLE, POOL DECKS, PRIVATE PATIOS AND LOTS, AND STREETS AND SIDEWALKS. 4. MONITOR AND MAINTAIN THE SYSTEM TO MtNtMIZE EQUIPMl!NT AND MATERIAL FAILURE. BROKEN SPRINKLER HEADS, LEAKS, UNRalABLE VALVES, ETC. SHOUl.D BE REPAIRED AS SOON AS THEY BECOME APPARENT. 5. EDUCATE ALL MAINTENANCE PERSONNEL ON A CONTINUOUS l!A!IIS OF THE PRESENCE OF RECYCLED WATER. PERSONNEL MUST BE INFORMED THAT RECYCLED WATER IS MEANT FOR IRRIGATION PURPOSES ONLY, ANO IS NOT APPROVED FOR DRINKING PURPOSES, HAND WASHING, CLEANING OF TOOLS, ETC. GIVEN THE HIGH TURNOVER RATE OF EMPLOYEES IN THE LANDSCAPE INDUSTRY, IT IS IMPORTANT THIS INFORMATION BE DISSEMINATED ON AN ALMOST DAILY BASIS. IT IS YOU, THE LANDSCAPE CONTRACTOR WHO IS RESPONSIBLE FOR EDUCATING EACH AND EVERY ONE OF YOUR EMPLOYEES. 6. OBTAIN PRIOR APPROVAL OF ALL PROPOSED CHANGES AND MODIFICATIONS TO Ntf PRIVATE ON-SITE FACllmES. SUCH CHANGES MUST BE SUBMITTED TO, AND APPROVED BY, THE DISTRICT ENGINEERING OFFICE AND DESIGNED IN ACCORDANCE WITH DISTRICT STANDARDS. 7. ALL RECYCLED WATER SPRINKER CONTROL VALVES SHALL BE TAGOED WITH IDENTIFICATION TAGS. A. TAGS SHALL BE WEATHERPROOF PLASTIC 3" X 4" PURPLE IN COLOR WITH THE WORDS 'WARNING RECLAIMED WATER-DO NOT DRINK" IMPRINTED ON ONE SIDE ANO "NO TOME EL AGUA" ON THE OTHER SIDE. IMPRINTING SHALL BE PERMANENT AND BLACK IN COLOR, use TAG /i8 MANUFACTURED BY T. CHRISTY ENTERPRISES OR APPROVED EQUAL B. ONE TAG SHALL BE ATTACHED TO EACH VALVE AS FOLLOWS: 1. ATTACH TO VALVE STEM DIRECTLY OR 'MTH PLASTIC TIE-WRAP OR 2. ATTACH TO SOLENOID WIRE DIRECTLY OR 'MTH PLASTIC TIE-WRAP OR 3. ATTACH TO VALVE COVER WITH EXISTING VALVE COVER BOLT. 8. ALL SPRINKLER HEADS SHALL BE IDENTIFIED AS RECYCLED WATER SPRINKLER HEADS. 11. EACH AUTOMATIC CONTROLLER AND ITS ASSOCIATED EQUIPMENT SHALL BE IDENTIFIED WITH A SIGN BEARING THE WORDS "RECYCLED WATER USED FOR IRRIGATION" IN ENGLISH AND SPANISH, WITH BLACK LETTERS 1" HIGH ON A PURPLE BACKGROUND. THE SIGN SHALL SE PLACED SO THAT IT CAN BE READILY SEEN BY Ntf OPERATIONS PERSONNEL UTILIZING THE EQUIPMENT. SHEET INDEX SHEET TITLE TITLE SHEET IRRIGATION PLANS IRRIGATION NOTES & LEGEND IRRIGATION DETAILS PLANTING PLANS PLANTING DETAILS AND LEGEN'.l LEGENO SHEET NO. 1 2-4 5 6-7 8-10 11 TYPICAL SIGNS rBLACKLOOO /lPIJfllfU 'llilCICGl'IOIN' 36" ~ t• lllACK LETTl!!RS 1 ECLAIMED WATER - 12" X36" SIZE .016 ALUM!~ .OIIO PLASTIC OR S 11CK-ON VINYL SIGNS. • 1' lllACK LETTERS 'Z' lllACK LETTl!!RS 19" X 11' 9IZe .016 ALUMINUl_,t.._.~ ABS P'I.A$T1C OR STICK-ON VlNTL SIGNS. DECLARATION OF RESPONSIBLE CHARGE I HIEREBY DECLARE THAT I AM THE LICl!:NSED DESIGNl!R OF WORK FOR THIS PROJECT, 'ftiAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT Ml DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONAL CODE, AND THAT THE DESIGN IS CON!llfflNT WITH CURRENT STANDARDS. I UNDERSTAND THAT THIE OHl!CI( 0/F PM>Jll!CT OAA\Mt N N/1#:J SPECIFICATIONS BY THE CITY OF CHULA VISTA, THE <YrAY WATER DISTRICT, AND THE COUNTY OF SAN DIEGO DEPARTMENT OF ENVIRONMENTAL HEAL TH IS CONl'INED TO REVIEW ONLY AND DOES NOT RELIEVE ME, M THE LICENSED DESIGNER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. THESE PLANS HAVE BEEN PREPARED IN l9l.lNITANT1Al CONFORMANCE WITH THE APPROVED LANDSCAPE C0NCll"f PLAN, WATER CONSERVATION PLAN, FIRE PROTECTION Pl.AN, AND CONDITIONS OF APPROVAL REL.ATED TO LANDSCAPING. ~~~c;..,,,c~yDATF·R·Z-M IS OTSUJI, R. 1557 ONA, INC. 9275 SKY PARK CT., #1 SAN DIEGO, CA 92123 Landloape .lro'.lllteetve • "'"•'•• \\11'•-Sk_y Park Pl-" •I'll llky Perk Court, lhalte 'DO .. . len lllep, CJ. •ma-48111 .. . 158.UI.IIOllO • ru 1118.2911JIOIT -PW-POTABLE WATER LINE -RW-PROPOSED RECYCLED WATER LINE -RW-EXISTING RECYCLED WATER LINE CW] EXISTING POTABLE WATER METER ll!WI EXISTING RECYCLED WATER METER & RECYCLED WATER SIGN (- f>I ,0 IWl'.5" APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. HAS BUIL TH TITLE-------- REVIEIJED BY• DATE ENGINEERING PLANCHECKER DATE INSPECTOR DATE -~Re,,EVl"-'S'-ION'--""'S'-'-'M!!!US:,,;Tc...,Be_eE'-=A"'-P""PR,.,_O-"'VE"-"D"-B-""Y""-P'-'-'U""BU.!..C.l:!.!.>HE""A"'-LTH='-'-'C.CN"-"GIN"-'-E--'R-"'-1----4---+---+----l:::I S=HlEE=T=-l~;=I~;=~:=~t:=~!~::::...::I SH(=lE1TS:::::I ,_bSST. PLANNING DIRECTOR AND DISTRICT NGINEER PRIOR TO IMPLEMENTATION IN FIELD. PLANNING DEPARTMENT DATE INl'llAL DA TE INll'IAL DA TE INITIAL ENGINEER OF WORK REVISION DESCRIPTION OTHER APl'RDVAL CITY APPROVAL I I I I I . EWPCF • OPERATIONS & MAINTENANCE FACILITIES SAN DIEGO COUNTY, CAUF'ORNIA ASSISTANT PLANNING DIRECTOR BY: PROJECT NO. DRAWING NO. ~~~D 8J~. JN PDP 0001 G 429-3L i . ! • I I• :::::: 911 l t-1,6,J 1-1\..11-1 e I \~~I 1,'' . • 1• I I ' \0 I -------:;,,;,',, -:-, '--""'"-f ... ---~ ~I-IL.II-I~ 2. ,. ij ~"C,Ul28-.:>r it • ,,. e Y I NC:! t..af M>-1i-.lL.11-lf: 2.~' \ fiZOt-\ ('.J;~ 1\-.\ \ 'f';! l'lo"lt 1e:, L-OT ~ SJ ri' -._ 2.o,A, : I 1..--....--9 14. 0 HGL m,. Et.EVA'l'lqN AT '1":1).c •. 32 Ft, lil'ATIC P@!!SSl,!M !Ill PSI . MIN. Gl'M 22.\ MAt)Gll'M ~-4 -- I I" I 11 --0-------------_ __,, ___________ _ ---- DATE!: 3/9105 JOB NUMBER: 03-004 JOB TITLE: ENC/NA WASTEWATER PLANT HGL: HYDRAULIC CALCULATION ADJUSTED STATIC PRESSURE METER NO. SYSTEM: , GPM: STATIC PRESSURE: 141 ~~ 1.30 BACKFLOW PREVENTER: 2' 8.90 REMOTE CONTROL VALVE: 1-112· 3.50 IRRIGATION SPRINKLER HEAD OPERATING PRESSURE: 30.00 2' 1.40 !SOLA TION BALL VALVE: 1-1/2' 1.00 'CHECK VALVE IN SPRINKLER HEAD: 3.00 BALL VALVE: 2' 1.00 5.00 ENCE: ELEV. OIFF. X.433 0.00 PSIL S 1.42 30' 0.55 1-1/4' 30' 0.33 1-112' 5' 0.11 2' 2-112" 2.41 2.41 1-112' 2' 875 33.8 7.88 2-112' 3• 4• SUB TOTAL 7.88 TOTAL PRESSURE LOSS: AVAILABLE PRESSURE PSI : AVAILABLE RESIDUAL PRESSURE: ADEQUATE ,, 14 -·-- ~1 2&>.0 -.------------. --- -. . I I I --- I I lfu~;;. Nl\;-ta:µ. ' \ 1 M>-lt-.lWl-lJ; I' C"-.!~CLJ'2E . ilJ \ L---,--,----·----- t-1!.l~ ,.::ie I' 2' I , , 22. l I I'? IL " lz. B3.B IIA KEYMAP :z:.r N.T.S. ~r~m~-· t . I ------- • A Vi;NIDA ENCINAS ------------- -,-...-;1--w~-~1o~A~. \:....J. I 11 21.-::, --.,..._ o· 20' 40' 60' 80' NOTE: MAINTAIN A MINIMUM 4' SEPARATION BETWEEN RECYCLED MAIN AND POTABLE MAIN. Landscape Architecture •Planning Sky Park Plaza SCALE: 1 "=20' -0" 9275 Skr, Park Court, Suite 150 Son D ego. CA 92123-4303 B58.292.2020 • Fax 858.292.2027 EQUIRED ON PAGE 1 ONLY I~~~=--~ APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLAN TING AREAS. DATE REVI E\J:D BY, n.J~ 1 4: · ~u o'tr INSPECTOR I SH2EET I CITY OF CARLSBAD I SHEETS I 1----11----+----------------1----t---t----1---1 PLANNING DEPARTMENT 11 1----11----+----------------1----t---t----1----1 DA TE INITIAL DA TE INITIAL DA TE INITIAL ENGINEER Of WORK REVISION DESCRIP TION OTHER APPROVAL CITY APPROVAL IRRIGATION PLAN FOR: EWPCF-OPERATIONS & MAINTENANCE FACILITIES SAN DIEGO COUNTY, CALIFORNIA t>I ri las-- ASSISTANT PLANNING DIRECTOR DATE DWN BY: AM PROJECT NO. ~~~D s;~, JN PDP 0001 G DRAWING NO. 429-3L -. -- ....... .._ {1 4" 3 WHP LINE (EXISTING) 2" GATE VALVE AT P.O.C. (EXISTING) - 2" -WYE STPIAINf.PI AT P.O.C.(EXISTING) EXISTING PUMP MAXIMUM FLOW @ 83 PSI MIN. Gf'M '19 MAX. GPM !ob.$ PUMP PFll!SSUPIE: 113 1'$1 • I .. ·• \" IB4 I --' -----22.1 0 ---~-- 7 I~-.31.2. I,, l/~ ,. . . . Of;:-~~~l~~ ---1--:$:J::. 2/o.(o 0 D -.4 / \ \ I_ o· C I. .. • 1. ' ' , 20' ' I I I I I q I I I I I I I I I I I I I I I I I I I I I I I 40' 60' ~ I-w w I Cl) w w Cl) I w z -....J 80' r··-!--i r.v:;;;;;;;;;.~i---~14a I I ··-··-··-··-··-··-··-··-··:-\ . . I \ I .. ---.. ' ----' L :r--- KEYMAP fll!li!' I N Ml\, Ii; IIY: - \;P·HOPERTY OWNER . Aft "A" '::!!l_STATION CONTJIIIOLLl!PI {l!l(ISIING: Rf;LOCAI!P) eie Qw+JM$-Pll1§"9N, • MODEL HUNTER "/CC" WALL ~UN'l'Ell. TO !IE 1111!:LOCATl!D. Pl'!OVH:)IE A~ INSTALL "F!.,\INGUAIQ" AUTO -IIIAIN SHUT CPI' Clil!VICIE - PIER MANUFACTUM Ftl!eOMM•i.tl'lATION -SI!! l'll!l'AH.. , STA1'!0N USED OPEN STATION 1•· .22.\ 111 \ti 4 I l:ATHRU IIA 8ATHRU-48A NOTE: ---------------- cz:::.r N.T.S. MAINTAIN A MINIMUM 4' SEPARATION BETWEEN RECYCLED MAIN AND POTABLE MAIN. Landacape Architecture • Planning Sky Por1< Plaza 9275 Sky Park Court, SUlte 150 San Diego. CA 92123--4303 858.292.2020 • fax 858.292.2027 SCALE: 1 "=20' -0" ENGl;;?;;;;;,:,1 EQUIRill ON PAGE t ONLY AP 4\ II lt.()ClV ENGINEE ING PLANCHECKER DATE APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. T II 4.21.0~ DATE I SH3EET I CITY OF CARLSBAD I SHEETS 1 · 1---+----t--------------t---t------t---t-----l PLANNING DEPARTMENT 11 t----+----t--------------+----+-----t----t--------1 'IRRIGATION PLAN FOR: EWPCF-OPERATl8NS & MAINTENANCE FACILITIES SAN DIEGO COUNTY, CALIFORNIA Ar~ 1:f'C2t1> • l---l----+------'------t---t--t---t-----1 ~~~ ............... "------A ASSISTANT PLANNING DIRECTOR DA 1E INITIAL ENGINEER Of WORK REVISION DESCRIP TION DA lE INITIAL DA TE INITIAL □THER IIPPR□V Al CITY APPROVAL DWN BY: AM CHKD BY: JN RV\JD BY, PROJECT NO. PDP 0001G DRAWING NO. 429-3L • -...... 0 ------I -- 0 \ D \ \ ~ ~ ~ -....., IRRIGA ION MA Al .IIY: . . PROPERTY OWNER VERIFY P.0.C. W/ OWNER ( :TING) • A .O.C. (EXIST! ER P.O.C.(EXIS PSI MIN. GP Je,_.o MAX. GPM '!>'1.,7 0 -- . "C" ---I<~ 6TAT19N OONTRObbER -~--+-________________ _ -0 ' MOOEL HUNTER "ICC" WALL MOUNTED. TO REMAIN. PROVIDE AND INSTALL . "RAJNGUARO" AUTO • PIAIN SHUT OFF DEVICE PEil MANUFACTUl'IE RECOMM,ENDATJON ·SEE . DETAIL ' USED STATION TO REMAIN IC THAU SC REPLACE STATION 9C THRU.,IIC OPEN STATION :2'4-C THAU 48C t,,1,!,1 iJ\..I NE: 2 1 e,,CV OF° C/J~ lfJC I 1, 2 - 19 C tac ·_ \" ,Zl.B - \ ti :2.1.4 -- ---'lr-M>4 IN~ \1 ~ O.,'-!.e, -I __ 4 ir..o' -- - 0 -T " -~ I ------L - ' 7 ~ ~-'f,7. ,;; ~ if' ls:.._ -= ---= M,6.1 N Lil-le-, 1 fi2ol-'1. W,t,..Ul I ' L. ' • ------~-. --'------------__ J ----- ' L _________ _ KEYMAP NOTE: .. -··-··~---··-··-··-··-··:\ '·-• ,, \ --__:_· .. \ :z:.;r N.T.S. ------ PROTECT EXISTING PLANTING AND REPAIR ANY/ALL CONSTRUCTION DAMAGE AS DIRECTED BY CITY INSPECTOR. AVf:NJDA ------ C:NclNAs -- o' 20· 40' 60' SCALE: 1 "=20' -0" EQUIRED ON PAGE 1 ONLY ,~~-~ 80' NOTE: MAINTAIN A MINIMUM 4' SEPARATION BETWEEN RECYCLED MAIN AND POTABLE MAIN. •· Landscape Architecture ePlannlng 'Sky Pork Plaza 9275 Sky Pari< Court, Sulte 150 San Diego, CA 92123-43()3 858.292.2020 • Fax 858.292.2027 APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. )3.Ull T" REVIEWED I BY• /1.J.. 6r:~ elL.oi\- lNSPECT□R 'f,il .c~ DATE I SH4EET I CITY OF CARLSBAD I SHEETS I t-----t----t--------------+---l-----4---1------1 PLANNING DEPARTMENT 11 t----+---t--------------+---l-----4---1------1 DA TE INITIAL DA TE INITIAL DA TE INITIAL ENGINEER OF WORK REVISION DESCRIPTION □THER APPROVAL CllY APPROVAL IRRIGATION PLAN FOR: EWPCF -OPERATIONS & MAINTENANCE FACILITIES SAN DIEGO COUNTY, CALIFORNIA ASSISTANT PLANNING DIRECTOR tJi/u lia DATE OWN BY: AM PROJECT NO. DRAWING NO. CHKD BY: JN RV'w'D BY, PDP 0001G 429-3L • J:_ ~ --0 • uJ r-- I ' IRRIGATION LEGEND (POTABLE) IRRIGATION LEGEND (RECYCLED) Dl!SC)UPTIONIMANUFACTURE!M.«>Dl!L I SYMBOL DESCRIPTION/MANUFACTURER/MODEL I ·a. ' NAhrul •"'· J. PMIATl'l ®~us.·· }i.,. ''" ' 'il'o' SYMBOL TVPe RADIUS PSI !'A.IRATE NOZZLE GPM DET.NO. TYPE PSI . ~ll!f, '' • RAINBIRD 1804 SAM-PRS. LAWN SPRAY FULL 12' 30 2.01 12F 2.$ A 0 RAINBIRQ 1804-SAM..PRS • LAWN SPRAY HALF 12' 30 2.01 12H 1.3 A 0 RAINBIRD 1804 SAM-PRS-LAWN SPRAY HALP 12' 30 2;01 12H 1,3 A ~ RAINBIAD! 1804-SAM-PRS • LAWN SPAA Y QUARTER 12' 30 2.01 120 0.65 A RAINBIRD 1804 SAM-PRS -LAWN SPRAY QUARTER 12' 30 2.01 120 0.55 A .. ~ RAIN81RDl 1804-SAM-PRS •LAWN STRIP SPRAY NOZZLE SIDE STRIP STRIP 4'x301 30 -15SST ,.2, A .. RAINBIRD 1806 SAM-PAS • STREAM BUBBLER QUARTER 5' 30 -50•1!1 0.5 A AAINBIRO! 1804-SAM-PRS -LAWN STRIP SPRAY NOZZLE END STRIP STRIP 41x151 30 -15EST 0.61 A H RAINBIAD 1806 SAM·PAS • SHRUB SPRAY FULL 7' 15 2.63 10F 1.18 A • AAINBIAD 1806 SAM•PAS • SHAUB SPRAY HALF 1' 15 2.83 10H 0.58 A ' AAJNl!IIA011805-SAM-PRS • SHAUB SPRAY HALF 12' 30 2.01 12H 1.3 A • AAINBIRD 1806 SAM•PRS-SHRUB SPRAY QUARTER 1' 15 2.63 100 0.29 A ' , RAINBIRD'1806-SAM-PRS -SHRUB SPRAY QUARTER 12' 30 2.01 120 0.55 A I">< I AAINBIAD 1806 SAM-PAS -SHAUB SPRAY FULL · 12' 30 2.01 12F 2.8 A ~ AAINl!IIAD1 1806-SAM-PRS • SIDE Sll'IIP STRIP 4'X30' 30 -15SST 1.21 A V RAINBIRD 1806 SAM·PRS -SHRUB SPRAY HALF 12' 30 2.01 12H 1.3 A RAINBIRD 1806-PAS-PAS -END Sll'IIP STRIP 4'X15' 30 . 15EST 0.55 A r7 RAINBIRD 1806 SAM-PRS-SHAUB SPRAY QUARTER 111' 30 2.01 120 0.85 A ,.r RAINl!IIRD 33DLAC QUICK COUPLER WI SHO-HOSE SWVIVEL (POTABLE WATER\ 150' o.c, D )! RAINBIRD 1806 SAM-PRS-SHRUl!I SPRAY SIDE STRIP STRIP 4'X30' 30 -15SST 1.21 A n AAINBIAD 1806 SAM-PAS-SHAUB SPRAY END STRIP STRIP 4'X15' 30 -15EST 0.61 A :., 1 RAINBIRD PEB-PAS-D AUTO CONTROL VALVE E&F 9 HUNTER PGP •3AV -XX SHAUB STREAM ROTOR WI FACTORY CHECK VALVE FULL 38' 30 0.3 9 4.2 • 7 l HUNTER PGP •ARV -XX SHRUB STREAM ROTOR W/ FACTORY CHECK VALVE HALF 38' 30 0.3 7 2.1 • ,c: HUNTER ICC CONTROLLIER (EXISTING) 41 STATION EXPANOABLE TO 48 STATION PROVIDE & INSTALL NEW "RAINGUAAD" K 4 HUNTER PGP -ARV -XX SHRUB STREAM ROTOR W/ FACTORY CHECK VALVE QUARTER 32' 30 0.3 4 1.2 II .\!lJi EXISTING !!EDUCED PRESSURE BACKFLOW PREVENTER rn HUNTER PGH ·ARV •XX SHRUB STREAM FIOTOR W/ FACTORY CHECK VALVE HALF 311' 30 0.3 7 2.1 C v'-J BALL VALVE "KING l!IAOS." LO TORO. MODEL G m HUNTER PGH -ARV •XX SHRUB STREAM i!IOTOR W/ FACTOIIY CHECK VALVE ' . .· QUARTI!R 32' 30 0.3 4 1,2 C CLASS 200 PVC LATEIIAL NON· PRESSURE (MIN.,!:OVERAGE 12" COVER\ I ... NOTE: ALL SPRINKLER HEADS LISTED Al!l,OVE SHALL HAVE A MANUFACTURER'S PURPLE CAP OR NOZZLES INDICATING RECYCLl!!D WATER -P---P-• SCHEDULE 40 PVC MAINLINE IMIN. 1'8" COVER I. FOii 1-1/2" AND SMALLER AND CLASS 315 PVC FOR 2" AND LARGE!! l&J NELSON 7645 QUICK COUPLER & 7841 QUICK COUPLING .KEY '150• O.C • !", . --' ---PVC SLEEVll 12 TIMES DIAMETER OF THE PIPE l!NCLOSl!Dl . AAINBIAD PESB•PRS-0 AUTO-CONTROL VALVE Sl!E PLAN FOR SIZE _,\.,, ___ L l!ld' UNDER VEHICLE PAVING -130 INCHES] FOR PRESSURE MAINLINE. WIRE & LATERALS IN SEPARATE PVC SCH. ao SLl!EVEI UNDER PEDESTRIAN PAVING -!18 INCHES) FOR MAINLINE & WIRE IN SEPARATE PVC SCH.40 SLEEVES !Cl HUNTER ICC CONTROLLER IEXISTINGJ 48 STATION EXPANDABLE TO 48 STATION PROVIDE & INSTALL NEW "AAINQUARD" K UNDER PEDESTRIAN PAVING• (12 INCHES) FOR LATERALS & WIRE IN SEPARAT~PVC SCH.40 SLEEVES ~ BALL VALVE "KING BROS." LO TORO. MODEL 1'1" AND SMALLER l . G STATION NO. -i ' M BALL VALVE• KING BROS.' BALL VALVE W/ UNION 12-1/2" AND LARGER! H di • GPM ... NOTE: ALL VALVE BOXES LISTED ABOVl! SHALL HA VI! A "PURPLI!" LID INDICATING Rl!CLAIMl!!D WATER -vALVE SIZE . CLASS 200 PVC LATERAL NON· PRESSURE (MIN. COVERAGE 12" COVEii\ "WATER WARN". 011 "ALERnlNE" PURPLE PIPE I ' ---SCHEDULE 40 PVC MAINLINE IMIN. 18" ·24" COVl!II l. FOR 1·1/2" AND SMALLER AND CLASS 315 PVC FOIi i" ANO LARGER I I J "WATER WARN" OR,'ALEATLINE" PURPLE PIPE ISEE SPECIFICATION! . lftfflGATIQN NQIU ---------PVC SLEl!VES 12 TIMES DIAMETER OF THE PIPE ENCLOll!!D) L 1. IRRIGATION SYSTEM IS DIAGRAMMATIC AND SHOULD BE VERIFIED IN THE FIELD 5, CONTRACTOR SHALL BE RESPONSIBLE FOR MAKING HIMSELF FAMILIAR WITH ALL UNDER VEHICLE PAVING -130 INCHES) FOR PRESSURE MAINLINE. WIRE & LATERALS IN Sl!PARATI! PVC SCH. 80 SLl!l!Vl!!S BY THE CONTRACTOR. IF CHANGES ARE NOTED IN THE FIELD THE CONTRACTOR UNDERGROUND UTILITIES, PIPES, AND STRUCTURES. CONTRACTOR SHALL TAKE UNDER PEDESTRIAN PAVING· 18 INCHl!Sl FOR MAINLINE & WIRE IN SEPARATE PVC SCH.40 SLEEVES SHALL NOTIFY ARCHITECT AND OWNERS REPRESENTATIVE PRIOR TO SOLE RESPONSIBILITIES FOR COST INCURRED DUE TO DAMAGE AND UNDER PEDESTRIAN PAVING • (12 INCHES) FOR LATERALS & WIRE IN SEPARATE PVC ICH.40 SLEEVES INSTALLATION OF IRRIGATION EQUIPMENT, CHANGES MADE IN THE FIELD MUST REPLACEMENT OF SAID UTILITIES, HAVE WRITTEN APPROVAL FROM THE OWNER FOR ADDITIONAL CHARGES TO THE JOB. 6. THE IRRIGATION CONTRACTOR SHALL FLUSH AND ADJUST ALL SPRINKLERS FOR " STATION NO. \ 2. CONTRACTOtll SHALL INSTALL THE FOLLOWING UNLESS OTHERWISE NOTED ON OPTIMUM PERFORMANCE AND TO PREVENT OVER SPRAY ONTO WALKS ROADWAY AND /OR BUILDING AS MUCH AS POSSIBLE. ' THE PLANS: GPM 7. CONTRACTOR SHALL INSTALL "AAINGUARD" AUTOMATIC SHUTOFF FOR ~~ A. ALL LATERAL END RUNS ARIE TO Bl! 3/4" IRRIGATION CONTROLLER; MANUFACTURED BY WATER CONSERVATION B. ALL LATERAL (NON-PRESSU'RE LINES CONNECTED DIRECTLY SYSTEMS INC. INSTALL PER MANUFACTURERS RECOMMENDATION, VALVE SIZE DOWNSTREAM OF THE REMOTE CONTROL VALVE) SHALL BE ONE SIZE LARGER THAN THE REMOTE CONTROL VALVE. 8, IN CASE OF WIRE FAILURE THE CONTRACTOR SHALL INSTALL TWO SPARE C. MAINLINE END RUNS ARE TO BE 1-1/2" CONTROL WIRES FROM THE CONTROLLER TO THE FARTHEST VALVE ON EACH 2. CONTRACTOFII SHALL INST ALL I!" POP-UP HEADS ALONG flUTUFIE WALKS AND LEG OF THE MAINLINE. THESE WIRES SHALL PASS THROUGH ALL VALVE BOXES ALONG THE MAINLINE ROUTE. THESE WIRES SHALL BE A DIFFERENT COLOR CURBS TYPICALLY. NO SHRUB HEADS ON RISER WILL BE ACCEPTED ADJACENT FROM THE OTHER CONTROL WIRES AND BE LABELED AS SPARE AT CONTROLLER TO FUTURE WALKS AND CURBS -SEE PLAN . POP-UP HEADS SHALL BE USED CABINET, IN THE VALVE BOX OF THE FARTHEST VALVE AND OTHER VALVE BOX, WITHIN 10' OF ANY PEDESTRIAN USE. 3. CONTRACTOR SHALL VERIFY LOCATION OF WATER AND ELECTRICAL POINT OF CONNECTION WITH OWNER. CONTRACTOR SHALL PULL NECESSARY PERMIT FOR WATER, ELECTRICAL, ANO TELEPHONE -VERIFY WITH OWNER, EXISTING CONTROLLER LOCATION ARE SHOWN DIAGRAMMATICALLY, FINAL LOCATION OF RELOCATED CONTROLLER TO BE APPROVED BY THE OWNERS REPRESENTATIVE. ◄. ALL PIPE AND WIR!E RUNS INSTALLED UNDER PAVING SHALL BE SLEEVED. SLEEVES SHALL se PER LEGEND ABOVE, ALL SLEEVES SHALL BE TWO TIMES TH£ DIAMETER OF THE PIPE OR WIRE ~ ... iYt1 -BUNDLE BE SLEEVED (2' MINIMUM) OR SIZED NOTED ON DRAWINGS, ~ ~ . "" CONTRACTOR SHALL COORDINATE LAYING OF PIPE, SLEEVES, AND WIRES TO ~ ENSURE THAT HE HAS ADEQUATE MEANS OF CONNECTION -SEE PLAN. ,A Landllcap• Arctiltec1111n1 •l'klnnlng -.. Ski, Par1< IPlan 1278 •r. ark Co<lll't, Sullit 190 ~OF c•~\ " Son D ~ CA &12123-43103 .. \ lfflll.292. 20 • Fax lfflll.292.2027 -- APPROVED FOR PLANTING 0 AS BUIL TN AND IRRIGATION ONLY, INCLUDING PRECISE TITL[ DATE ENGINEER S SIGNA 1\JRE REQUIRED ON PAGE 1 ONLY LOCATION OF PLANTING REVIEIJED ItY, APPROVED AREAS. ENGINEERING PLANCHECKER 0ATF INSP[CTOR DATE I S5ET I CITY ClF CARLSBAD LUJ PLANNING DEPARTMENT 1 IRRIGATION LEGEND & NO, F'OR: EWPCF • OPERATIQN,S & MAINTEN.ANCE FACILITIES SAN DIEGO COUNTY, CALIF'ORNIA A~ ~~ q, '" ~!?1..-ASSISTANT PLANNING DIRECT~ DAE: DWN tlY: PROJECT NO. DRAWING N'O. DATE INITIAL DATE INITIAL DATE INITIM. REVISION DESCRIPTION CHKD BY: JN PDP 0001G 429-3L ENGINEER Of' WORK DTIO ~l'PRDVIII. CITY AP1"ROVAI. RV\./D BY, ' ' ~~rfjl<t.EA ~AOS-WfniOUT FACTORY INSTALLED ANTI-DRAIN VALVE SHALL INCORPORATE AN EXTERNAL FLOW 1-.,SHUT-OFF VALVE AS A PART OF THE 1:' SPRINl<LER ASSEMBLY. ,,. .. . . r1 : _- J y--4• OR 6" POP-UP ' I I .---FINiSH GRADE · · 2" MIN:-..._ I I - 810EWALK OR CUR----. . • 1 I -. fi_/ I '! LUl-----4• OR El' POP-UP ' SCHEDULE 80 PVc.~---- NIF'PLE LENGTH AS REQ. SC~DULE .80_ PVC 1 -NIPPLE LENGTH AS RE!Q. •-, SPRAY HEAD W/ . FACTORY INSTALLED' CHECK VALVE J -NOTE: INStALL PVC -. , ELLS SO THEY TIGHTEN W/ -_ DOWNWARD THAU.Sf OF RISE_R · tf"t:~1• . T .; .._ ___ • I ----~..,, MARLEX 90° STREET · ELLS (3 TOTAL) __ ..,..: LATERAL PIPE . . . . . 4" & 6" POP-UP SPRINKLER HEAD ! l"VCUNION I SCM. 80 '~ ,• 1 ···-·. •• · SCHEDULE 80 PVC '. THAEADED ~PPL!: flll!!CT ANGULAl'I ffl!!FIMOf'LASTIC ,' VALVE !!OX (1) CINI: VALVE PER BOXTYP. - . SCHEDULE 40 PVC ·e:Ll!OW I AUTO CONTROL Wll'IE I . . : ~:HEDULE 40 MMNUNE--- i AUTO • CONIROL VALVE f NO SCALE- I i, I GEAR DRIVEN ROTARY HEAD STAINLESS STEEL V.I.T. -~ SPRINKLER TIE W/ PROTECTIVE VINYL TUBING (2 EA. REQ.) CHECK VALVE OR COUPLER-~ USE FACTORY INSTALLED CHECK VALVE IN HEAD IF AVAILABLE. 3/4" SCHEDULE 80 PVC RISER. ' J' 'l · WALK/CURB.--.__ /5 BOTTOM OF SLOPE. 'l 1/2" DIAMETE~E;-BAR STAKE. ----rwo MARLEXo• SCHEDUI.E '40 PVC TEE OFI ELL· . STREET ELLS V.I.T. PRODUCT$ 2083 WINIEF11DGE PL.AC~ ESCONDIDO CA 92029 . 800) 729-13.14 FAX (BBB 310-3948 'GEAR DRIVEN ROTARY HEAD • ~-:1'--.ct,OLDER WIRES PRIOR TO --, FILLING W/ SOLVENT_ iwe.;;e.,,-.oue;;;st:;;G;;;N;rr:;:;;,, ' . . . . !• ALLOWS t=:ASY tNSl:l=iifON OF WIRE : EXPANOS TO APPROPRIATE WIRE SIZE, '.. 1 AND SEALS ANY UNUSED HOLES TO PREVENT SOLVENT RUN OUT. '. WIRE CONNE:CTOR SIDl::WALK 01'1 CUR LATERAL PIPE ------ SCHEDIJLE 40 PVC TEE MARLEX90° STREET ELL SCHEDULE 80 PVC NIPPLE (LENGTH SIZE AS REQUIRED) . a: o:c-1Lti: I OW, ' zo w_. ' C!l~, ,W ' ..I ' w ttl_ 4'.1- , Cl) c.J --FINISH GRADE \ ,....__12" POP-UP SPRAY OR GEAR DRIVEN SPRINKLER . -HEAD W/ FACTORY INSTALLED ANTI-DRAIN VALVE CUCK CCII.ft.ER VALVES SHALL lll!OF A TVPIE APPAOVl!D l'OR FIECYCLED WATER USE · ROUND THERMOPLASTIC VALVE BOX QUICK COUPLER : : VINYL COVERED . C 2'SHRUBBED. 1/2" LAWN ..-~~~~-I!--. e.-=~---....... o.,jl!,, ___ ..... % t■.'!'■."!""'!""!'l'"!""!'!~---• j. -~-- . 3/4" SIZE GRAVEL ____ , 1 CU.FT. 1 CU. FT. '.""'. -----.J CONCRETE 1 EA. BRASS::'::;:::=a RISER'ANP NIPPLE R?,- 4X8 BRIC!( TYPICAL - (-4 · REQUIRED) ·- NATIVE OR COMPACTED SO1 ; PVC MAINLINE, i . . . -. SCHEDULE <4(1 PVC 'ADAPTER . f• 8E A8SEMl!LEO WITH TEFLOf,/ ATEDT P 12" POP-UP SHRUB SPRAY & GEAR DRIVEN SPRINKLER HEAD ·0u1cK COUPLER VALVE i IN VALVE BOX - . EDGE OF FIXED IMPROVEMENTS !, 12" MIN. i 18" MAX .. • SCHEDULE 80 PVC.---.... ; NIPPLE ! PVC MAINLINE • !•" (D . ' SCHEDULE 40 PVC COUPLER!j~~~ro~~ o • 4X8 BRICK TYPICAL-.__.~ , (4 REQUIRED) · COMPACTED OR · -. _.,,.,..,.-;' -UNDISTURBED SUB-GRAD~ . flOUND THERMOPLASTIC , .. 'VALVE SOX•: ·:,:, . ! LO-TOAQ. PLASTIC BALL VALVE ' ALL THREA E J SHALL . BE ASSEMBLED WITH TEFLON COATEDTAP TYPICA ............ Afd,ltectun, ......... Sky Park Plaa -· LO-TORQ PLASTIC BALL VALVE• 1275 Skr. P«tc Court, SUlh 1eo SGn D ego, CA 112123-4303 858.292.2020 • f'ax 8!111.292.2027 ENGINEER S SIGNA TIJRE REQUIRED ON PAGE 1 ONLY APPROVED ENGINEERING PLANCHECKER DATE APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. "AS BUILT" TITLE ______ _ DAT£ REVIEIJED BY• INSPECTOR I SH6EET I CIT OF CA .,.,.._,BAD ~ l--+--1---------------t----+--t--+---1 ~;;;:;:~;::;;;,~P,;L;=AN~N~IN::::G::::::DE:::P:::AR::T::i'l:::tN::T===:::..::LJ1_J=1::1:::::, 1----+---+-------------+---+--t---i----; I IGA ON OETAILS F'OR: EWPCF • OPERATl9N•S & MAINTENANCE FAC:l·LITtl!S SAN DIEGO COUNTY, LIFORNIA I ~~ re Ca,,A ti1u '"'cl t===~t===t============:=::::::::::::~::::;.:::~====~==~ ASSISTANT PLANNINCi l)IRE:CTOR DA ¥f 1----'---1---------------+-c-=-+=--+-:,-cc,:--r==:"'.".""'1 DWN Y: PROJECT NO. DRAWING NO. DATE INtllAL 1-DA_TE__.~INl_ll_AL-t-_DA_TE__._IN_lll_AL-t CHKD BY: JN PDP 0001 G 429-3L ENGINEER Of' WORK REVISION DESCRIPTION CTHEll APl'IIOVM. CITY APPROVAL RVIJD llY• I ' E.OG! OFFIXEDIMPAOVEMENT 12" MIN .. ·· 18" MAX,. l!~ .SHRl.le:BEO. 1/2" IN LAWN . --ilrtil!i'!!!!"IP!!lt ... ·"' i. I . . ~....;...-----~i;.--· .PVC PIPE ... EX!ENSION SIZE A$ .R&:OlJI.RED. · TYl>iCAL · · . -r--,- . I~,, / / / .. · ·. // / /,.....__.......__,.,, BALL YALI/E WO.INION . . . . 4XB BRIC!< TYPICAL ,.P.RES$.Uf\E MAINLINE; PIPE . . • . r . SCHED. 80 p~ NIPPLE ---·scR~D.80 PVC NIPPLE 1" 1·1/4" 1·1/2 2" 1-1/2" 3". · ~ ·0AA'ltf!I.! . .· &,1!).?Q!,J, FT- :e~:J_L ,·VA~ ve:·:yyl:TH .·UNION ' .. . . . . -. ' ., .,. .. . . . 2-1/2" 3" . 3" 4" .4•• 8" •• •• . NOTE: ·SLEEVE CHAIIT IS FOR THI! CONVENIENCE TO THI! CONTRACTOII. CONTl'IACTOA 8HALL PROVIDE! ADEQUATE PIPE SLEEVE SIZE TO ACCOMMODATE THI!! INSTALLATION OPTHI! lflPIIOATION PIPE AND RE8 . SLEEVE CHART FOR IRRIGATION . . . I PIPE AND WIRES·• I I I I I . . , .. ,.. . . L-.A--coMPACTED BACKFILL . SEE SPECIFICATION /:._.,?_k---COMPACTED CLEAN FILL SOIL • SEE SPECIFICATION L +-1~~~-~r.-'~lt:°--PVC LATERAL· SEE . • • ._ ' .• >,• LEGEND FOR TYPE · . , .. . . .. . •· . . .... ' • _... . . • • '§:!. . .: :/ -_::::::::,--RECYCLED WATER • •fat;. _ _j WARNING TAPE ---PVC MAINLINE .>J-7 SEE LEGEND FOR TYPE .. .... ~~t'-1-. --~·-r.ii.'PE AN·o BUNDLE .. -·.. . . CONTROLLER WIRES EVERY 10' TYPICAL .. MAINLINI! -PVC CLASS 315 • 2 INCHES OR LARGER, SCHEDULE 40 • 1·1/12" OR SMALLER· MIN. 18 INCHES (PRIVATE), 21 INCHES (PUBLIC) BELOW GRADE, MIN. 24 INCHES . BELOW PAVING. . . LATERAL LINE· PYQ QI ASS 200 (PUBLIC PROJECTS SCHEDULE 40) MIN.121NCHES (PRIVATE), 15 INCHES (PUBLIC) BELOW GRADE, MIN.18 INCH.ES BELOW PAVING. · · ' -IRRIGATION TRENCH DETAIL r STREET SURFACE ~-· -POTABLE MAINLINE ... ~ , .... 9·0• Bwid• Sin A ·B !:fii !)" e" . rt" e" ,o .. e" 12.'' 12" 10". 16" 14° I 12 N • 2011 16" r " J ~ ~ (SEE IMPROVEMENT DRAWINGS) 12"-MINiMU~i REQlJIREb VERTICAL SEP1t.-i'iA'tiofJ..., :· ~rcCAIM!:D ·wAfER iRRTGATIOffMAINLINE-· -- : ·Nore: ' ·· ··· · · · · -----· --· · ·· ·•· ······-·· ··· ······ . All RECALIMED WATER IRRIGATION AND SLEEVES SHALL BE PURPLE ANO LABELLED AS SPECIFIED IN: . ' STANDARD SPECI.FICATIONS FOR PRIVATE IRRIGATION SYSTEMS' CARLSBAD RECLAIM:,\TION RULES AND REGU;LATIONS FOR . CONSTUCTION OF RECLAIMED. WATEFt MAIN'S, OCTOBER 1993 ~-..... NO SCALE .. . IYPIOAL MOUNIJNG UstNG INSTALLATION KIT Tl"IIIINAL tOIP 2 3 0 0. 0. : E.AVE MOUNT , . .. 1 BEND BRACKET TO I KEEP RAINGUARD LEVEL. . . ' WATERPAOOF iWIRENUT ' ' ' . ' IFLATROOFMOUNT • jKEl':P RAINGUARO LEVEL ' 1:Z~1J~:;;oo, ' ' ATTACH WIRE TO WALL WITH APPROPRIAJE WA. L~ CLAMP. WIRE SHALL Bl; THE SAME GAUGE AS usaD PER IRRIGATION INSTALLATION. · . • MMITEA (.) . 0 2-4V, • VALVE M ,owll'I 0 0 0 a • " A&D YELLOW ·1 !IIIIIIITO■.R■Al■N ■GU■A■A0 .... --~,111!!:::;:--'-_j I .: ' IXIITING VALVE --,. COMMON WIRl(I) . --' 4~•Btnd1 22:,,eenci Ttll · Capa: Croiau • ~~~ACTOR $HALL VERIFY CONNECTION WITH MANUFACTURER PRIOR TO CONNECTION OF CONTROLLER-VARIOUS OTHER : A 4• 611. B" • 10" · 12" B A B A ·B C D A B· 6" 2.• 6n, 6" g• e" 14" .6" 6" a,,:,e,•··. 3-~-.••ell .. B~-8.~~ ··10" 20" e" ·8"· 10"· '••5~ 9" 9" ·12° 12" ZT" 9• io" ·12" ·6•· 1.0 I 1° .14·· . 14" 34• . 11° 12· 14'''· . e• I I",. . 14°' 16" 16 41" 14" 14" ..... ' .... 0 . : THRUST QI,. .OK$. ·,o· Mifli1MiJM to POTABLE . --,_ --.. ----. -' MAINCINE TN STREET NOTE: 12• MII\IIMlJtvf CONTROLLERS HAVE DIFFERENT CONNECTION. CONTACT: WATER CONSEAVA110N SYSTEMS, INC. 840 WEST NINIIJl,.STREET SUITE D UPLAND, CALIF'O'RNIA 91786 TEL: 714 920-3131 "RAIN GUARD" lNSTALLATION ON1 . . . \BUILDJNG Q ,._ ___ R,..O"E,.:CL'.AIMED '\"ATER W/SLEEVE VERTICAL CLEARANCE OF 12" MINIMUM IS MANDATORY WHEN CROSSING PATH OF A POTABLE WATER LINE. INSTALLATION OF RECLAIMED WATER IRRIGATION · MAINLINE 24'' FROM FACE OF SIDEWALK WILL PROVIDE THE NECESSARY 10' HORIZONTAL CLEARANCE Fl'!OM POTABLE MAINLINE IN THE STREET .. ..-,-.... ., ....... , ., .. , .................. ·····•-··--··'·"'·•··'·· .... ·.,.,_,_ . . .. ····.·. ' ... , .. -~· .. . . POTABLE SERVICE LINE CROSSING, . .......... , .... _,_._ .. ,., .... , .... , ....... . ENGINEERS SIGNATURE REQUIRED ON PAGE 1 ONLY APPROVED ENGINEERING P ANCHECKER OAT[ IAft"-pe Anlllltecture .......... Sky Park PICD.111 12711 Sk5arl< Court, ~ t!IO San CA 92123-4303 111111.292. 0 • Fax 1118.292.2.027 APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. HAS BUil T# TITLE ______ _ REVIEw'ED BY• INSPECTOR DAT[ DATE t----;----1--------------+---+--+--+---ILLJ ITY OF CAR PLANNING DEPARTMENT ~ LllJ DA TE INITIAL. DA TE INITIAL DA TE INITIAL ENGINEER Of WORK REVISION DESCRIPTION ano Al't'll!IVIII. CITY APPROV~L I IGATION DETAILS FOR: EWPCF -OPERATl10NS & MAINTENANCE F~Cl:l.1ll1ES SAN DIEGO COUNTY, CAUFORN'IA -~-JL_""',."""'"'...,,, .... r...e.__"' .... ~c;..;;...:ao'------1r uar AJ?J'~:-"\-,._, I ~ ASSISTANT PLANNING DIRECTOR DA PROJECT NO. DRAWING NO. JN PDP 0001G 429-3L I -1 0 I # BRA. EDU. 22 ~ 10'B.T.H.~ # ----..___ RHA. IND. 'B.' 283 --------~--------------------------+--l~------"-.:5:.:GA=L~. ---------1- ' ~-~-~--~~ • MAG. GRA. 'L.G.' 12 15 GAL. EUR. PEC. 40 @ 5GAL. o PHO. T N. 'C.' EX. TREE TO EMAIN • -- 3 PIN. TO 24" BOX 12" O.C. GAZ. 'S.Y.' & 'S.' FLATS •• • 1 MET. EXC . 36" BOX - 12" O.C. AGA. AFR. 1 GAL. 0 CYC.REV. 6 N/A OPH. JAP. .........___ I I • I ~ I •I ' I I •ii~::}::it;};:(:i):l::.r\ .. -...... 4 HA. OVA. 189 (l) 5GAL. HEM. ---------------------------------o· 20· 40' 60' SCALE: 1 "=20' -0" REVIEv.£0 BY: ENGINEERING PLANCHECKER DATE ··-··-··-··-··-··-··-··-··:'\ 0 ---......_j_ KEYMAP CLY. CAL. 2 A \ [ I lw z - R.O.W. 5GAL. - --~ 80' Landacape .Architecture • Planntna Sky Park Plua 9275 Sky Park Court, Suite 150 San Dle1_0, C.l 921234303 858.282.2020 • ru: 858.282.2021 APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING REVIEWED BY, AREAS. INSPECTOR I i T" ' DATE DATE REVISIONS MUST BE APPROVIED BY PUBLIC HEALTH ENGINEER I SHBEET I CITY OF CARLSBAD LUJ ASST. PLANNING DIRECTOR AND DISTRICT ENGINEER PRIOR TO l'-IM=P=L~EM~E~N~T~A TJ~O=N~IN=Fl=EL~D~. ~~~~~==~~~~-+---+----+---t----f PLANNING DEPARTMENT t'-=-"='-=r'-'-'-'-"=.;--"-'-'--'="-------------t----+----11----+----I DA TE INITIAL DA TE INITIAL DA TE INITIAL ENGINEER Of WORK REVISION DESCRIPTION OTHER APPROVAL QTY APPROVAL PLANTING PLAN FOR: EWPCF -OPERATIONS & MAINTENANCE FACILITIES SAN DIEGO COUNlY, CALIFORNIA A_._(}-"~'--"VIE'"""~=-...,.,W.......,.~"'-""-'-~----9-/ (--0-1 ASSISTANT PLANNING DIRECTOR DATE DWN BY: AM PROJECT NO. DRAWING NO. 2~~0 B;~, JN PDP 0001 G 429-3L -· i : I I I I I I I I \:QJ I ------0----------------J 1 I I I I :□ I I I I I qJ D • AG. GRA. 'LG.' · 13 GEL PAR. 5 15 GAL. PHO. TEN. 'C.' 38 5GAL. 9 10' B.T.H. 11 I I I I I I I I I I I I ! I I I I I i I I I I I I I I I I I I ! I I I I I I I I . ---l------·--.. -· ·--- ' • I I I KEYMAP L _________________ -----j--- «li: N.T.S. I I I I I I EUR. ~EC. 42 @ • • • Q--...ll::l:El~~" \ '-......! __ _ I --t ---f -- .,._ __ - • EX.TOR~E ~ MAIN HA.OVA. 95 ~ 5 GAL. oCI -PIN. TOR. 24" 12" O.C. GAZ.. 'S.Y.' & 'S.' FLATS -- / I 5GAL. 0 . ' '. ___ / NAN. DOM. 'C.' r-, ,___J 37 5.GAL. O RHA. IND. 'B.' 61. 5GAL. -- FSITE, TYP --....____ ·-.. --..;; .. ~ .. :----. ,__ . ..._ - =--~--=~-:--,---.. --© 5 :AL LAN. 'S.S.' . ··r-:.;/ -- ~~-J_HEM. HVB. 'B.' 4"POTS . ~ (SOUTH~lVEJ -~ --6' O.C. LAN. MON. -- 1 GAL. --- ---...., __ -- R.O.W. LtmdHe.pe 4Nlllteetve • Dlq,tq 1111:y Park Plue. ---lll'l'II 1111:y Puk Court, lhlle IN Sea Dlea,, C4 9111111-4801 1118.8118.II02a • Pu: 8158.atl.lCll'r SCALE: 1 "=20' -0" REVIEWED BY: APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. HAS BUil T-" TITLE ______ _ REVIEIJED BY• INSPECTOR DATE D,t,TE ~ L.l1J 1------+--+-----------+---+---l~-+---I ,:1-,,~~~~;A..:~~f}L,-,Q~k,b~=~--!l ltOf}TEfll' 1-----+---1---------------+---+---f--+---I ,t,SSISTANT PLANNING DIRECT t Y: PROJECT NO. DRAWING NO. 2~~o 8lv, JN PDP 0001G 429-3L DATE INl"IIAL ENGINEER OF WORK REVISION DESCRIPTION DATE INITIAL DATE INITIAL DTIO N'PffN/4.. CITY A-OVAL I I ; I -0 l"'---t"') _, - . I I I I I I I 0 \ □ \ \ ~ ~ 0 0 I I --------------------------------------------------------------------------I _;---. -... -... -------' --I ~--.... L______________ __J ----- I I l I -......: __ , I \ ij ~1 ~I---/ ~I LiLJ I i W' W' en I - ------- I I ---J -- I I -- - I I --1 .... __ ---- I I I ----- D DcO BRA. EDU. MOWCURB TYP. ------- HYB. "B.' -------------------------------- -- ------- KEYMAP N.T.S. GEi. PAR. 15 15 GAL. RHA. OVA. 620 5GAL. 12" O.C. GAZ. 'S.Y.' ==~FLATS 48 5GAL. LAN. "S.S.' 125 + 5GAL. LAN. MON. 6' O.C. 1 GAL. EXISTING PLANTING TO REMAIN . . R.O.W. ----------------_--:::-..._ -~--~.c.. ----------------- O' 20' 40' 60' BO' ---L•...,.,. .troldhet•n • Pleaatac ~--, lb Park Pl... •• -------911'1'II lb Park Com-t, bite 190 San Diep C.t 1111111-4308 1118.2111.2020 • rax &111.112.1111'1' SCALE: 1 "=20' -0" REVIEWED BY: ENGINEERING PLANCHECK R DA TE APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. NAS BUILT' TITLE ______ _ REVIEIJED BY• INSPECTOR ING PlAN FOR: DATE DATE EWPCF • OPERATl'CilNS & MAINTENANCE FMCllll"f,fES SAN DIEGO COUNTY, CALIFORNIA l---+-+----------l---li..---1--1.------1 Am~~ fJ:,Cock e[o LPL l----i---+--------------4---1----l---f..---1 ASSISTANT PANNING DIRECTOR 0-'iTE DAYE INITIAL ENGINEER OF WORK I REVISION DESCRIPTION DA 1E INITIAL DA lE INITIAL OTHER APl'RIIVIII. CITY APPROVAL JN PROJECT NO. DRAWING NO. PDP 0001 G 429-3L I ' ' l ' ' ' -o ...... -...., C) I , TWO AT TOP OF STAKES OTHERS WHERE NEEDED TO SUPPORT TREE TREE ST OUTSIDE 4" PERF. DRAIN PIPE TD BO OM ROOTBALL W/ 4" PVC DRAIN CAP/GRATE (BLACK) .HQR; (2) lREE BUBBLERS AAE POSITIONSD IIO' TD PERF. DRAIN PIPES S-MIN.BAl!IN FINISH GRADE @ TREE PLANTING & STAKING NOSCN.E 311191 Ol!1"TliOF IIOOTI!IALL 2X ROOTSAU. SPREADONW ORWIRE lll.011£ 1"/FT. 3" MIN BASIN FINISH GRADE !LIZER TABL T CROWN @ VINE PLANTING D """""N .. o""'SCAL.,,_..,.E ___________ ~-=e- DEPTH OF AOOTBALL I I I l'o 11 f !5 !5 es 1~ Pl\LMTREE 4" PEAF. PVC DRAIN PIPE W/4" PVC DRAIN CAP/GRATE (BLACK) 6" MIN. BASIN FINISH GRADE -·-- 111 - PLASTER SAND -PUDDLE & SETTLE PRIOR TO SETTING TREE SCARIFY SIDES & BOTTOM SLOPE 1"/FT. 4" PERF. PVC DRAIN PIPE W/4" PVC DRAIN CAP/GRATE (BLACK) 12" ~2Xc,..:R.::::00=.TBc:Ac=LL=--..i."'--~--=3/4::.;:"..:.PEA.:;a,:.:G:::;RA::.:.V:.::E::;.;L S::.,:Uc:,:MP,___ ®-N~~~...;.;c~~M.....;.T.....;.R.....;.E;.....E;.....P_LA_N __ Tl;.;..;N;..;;;.G ___ _ PLANTING DISTANCE SCHEDULE l'EET ON ,CENTER ROW DISTANCE SETBACK 'A' -8" 1'--0" 1'-3" 1'-6· 2'-0" 3'--0" 8'--0" 8'--0" 10'-0" 12'--0" 20'-0" 'B' -'C' r 7" 10 1/2" 11" 11" 1·-0· 1•-t• 1'-0" 1'-9" 1'-6" 2'-8" 2'-6" 5'-2" 5'-6" 6'-11" 7'-6" 8'-8" 9'-6'" 10'-6" 11'-6" 17-4" 19'-6" PLANTING ORIO •••••••• •--;t . . . . . . . -~ • • • • • • • • • -• ...... -~ . . . . . . . . ~ • • • • • • • • ........ •-~ t.) DEPTH OF ROOTBALL 2X ROOTBALL SHRUB SLOPE 1 "/FT. 3" MIN BASIN FINISH GRADE - ARED BACKFILL MIX FERTILIZER TABLETS ROOTSALL-SET CR 1" ABOVE FINISH GRADE ... • C -----© SHRUB PLANTING NO SCALE 318196 CONCRETE MOW CURB SCORE JOINT SEE NOTE#2 --1" IN LAWN AREAS 2" IN SHRUB AREAS ~-PLANTING AREA {SEE PIJ\N) PLANT LEGEND TREES SYMBOL ABBR. BOTANICAL NAME BRA. EDU. BRAHEA EDULIS CYA. REV. CYCADA REVOLUTA GEi. PAR. GEIJERA PARVIFLORA COMMON NAME GUADALUPE PALM SAGO PALM AUSTRALIAN WILLOW SIZE/SPACING REMARKS DETAIL 10' B.T.H. 24"1!1OX 15 GAL. I SUPPLIED BY OWNER B A MET.EXC . METROSIDEROS EXCELSUS NEW ZEALAND CHRISTMAS TREE 36" BOX MULTI-TRUNK STD. TREE FORM A A A SYMBOL @ (£) 0 C EB 0 MAG. GRA. 'L.G.' PIN. TOR. SHRUBS ABBR. EUR. PEC. 'V.' LAN. 'S.S.' NAN. DOM. 'C.' PHO. TEN. 'C.' RHA. IND. 'B.' RHA.OVA. VINES MAGNOLIA GRANDIFLORA 'LITTLE GEM' PINUS TORREYANA BOTANICAL NAME EURYOPS PECTINATUS 'VIRIDIS' LANTANA 'SPREADING SUNSET' NANDINA DOMESTICA 'COMPACTA' PHORMIUM TENAX 'CAROUSEL' RHAPHIOLEPIS INDICA 'BALLERINA' RHAPHIOLEPIS OVATA MAGNOLIA TORREY PINE COMMON NAME EURYOPS LANTANA HEAVENLY BAMBOO NEW ZEALAND FLAX INDIA HAWTHORN HAWTHORN SYMBOL ABBR. BOTANICAL NAME COMMON NAME CLY. CAL. CL YTOSTOMA CALLISTEGIODES VIOL.ET TRUMPET VINE GROUND COVER SYMBOL ABBR. BOTANICAL NAME COMMON NAME AGA. AFR. AGAPANTHUS AFRICANUS Lil Y-OF-THE-NILE HEMEROCALLIS HYBRIDS 'BITSY' HEM. HYB. 'B.' (LIMONIUM PEREZll 30% WHERE INDICATED) DAYLILY GAZ.. 'S.Y.' & 'S.' GAZANIA 'SUNRISE YELLOW & 'SUNBURST' GAZ.I.NIA LAN.MON. OPH.JAP. LANTANA MONTEVIDENSIS LANTANA UNDERPLANT GAZANIA 'SUNRISE YELLOW & 'SUNBURST' GAZANIA OPHIOPOOON JAPONICUS MONOOGRASS NOTE: 15 GAL. 24"BOX SIZE/SPACING 5GAL. 5GAL. SGAL. 5GAL. 5GAL. 5GAL. REMARKS SIZE/SPACING REMARKS DETAIL C C C C C C DETAIL 5 GAL. ATTACH TO WALL D SIZE/SPACING REMARKS 1 GAL. 0 12" o.c. 1 GAL. @ 12' O.C. FLATS@ 12" O.C. DETAIL E E E 1 GAL. C 6' 9.c. 3' SETBACK FR. WALK e FLATS@ 12 O.C. FLATS@8" O.C. E ALL PLANTING AREAS TO HAVE 3" MULCH COVER. SUBMIT SAMPLE TO CITY INSPECTOR FOR APPROVAL PRIOR TO BULK DELIVERY TO SITE . LIia-ape .lrollllltHlllft • Plaaatai Slry Park P1en ® GROUNDCOVER PLANTING E i--------- lfftS ft]' Park Court, 111th 1111 San l>Laao CJ. 1111119•'809 1118.218.2020 • J'u: 8111.111,IOl'I' HAS BUIL TN NOSCAI.E NOTES: 1. REBAR SHALL l!E CONTINUOUS W/12" OVERLAP. 2. PROVIDE 1/2" EXPANSION JOINTS@ 30' O.C. & 1/11" X 1-3/-4" SCORE JOINTS@ 10' O.C. ® CONCRETE MOW CURB F ----------SCALE: 11/2"=1'-0" ' I I ENGINEER'S SIGNA lURE REQUIRED ON PAGE 1 ONLY REVIEWED ENGIN ERING P ANCHECKER DA APPROVED FOR PLANTING AND IRRIGATION ONLY, INCLUDING PRECISE LOCATION OF PLANTING AREAS. TITLE ______ _ DATE REVIEYED BY• INSPECTOR DATE ~ CITY OF CARLS AD ~11 t===jt===t==========================1====t=:=1====t==~ UlJ PLANNING DEPARTMENT UlJ LANTING LEGENO & DETAILS R: EWPCF • OPERAT<ICDNS & MAINTENANCE FAC:1,1..••1,ea SAN DIEGO COUNTY, CALIFORNIA Ayf?'VED 1\(. A ~ 1----1---+-------------+---+--+--+----11,..'... •~~~-.1..{.""'' 4CJ...._1.,!.L~.11:'it1..l.i.i...,~--------s o· 1----1---+-------------+---1---+--+----1 A SISTANT PLANNING DIRE TOR " DA TE INITIAL ENGINEER Of WORK DATE INITIAL DATE INITIAL OTHER N'PRIIVIIL CITY APPl'!OI/AL REVISION DESCRIPTION Y: CHKD BY: JN RV'wD BY• PROJECT NO. . DRAWING NO. PDP 0001 G 429-3L I ,