Loading...
HomeMy WebLinkAbout1969 PALOMAR OAKS WAY; ; FS060012; PermitCity of Carlsbad Fixed Systems Permit Permit No: FS 060012 1969 PALOMAR OAKS Job Address: WY Permit Type: FIXSYS Parcel No: 2130922000 Lot #: 0 Reference No.: Status: ISSUED Applied 7114/2006 Approved: 7/17/2006 . Issued: 7/17/2006 PC #: Inspector: Project Title: SCHUMACHER 13 SPECIAL CHEMICAL AGENT SUPPRESSION SYSTEMS Applicant: SCHMIDT FIRE PROTECTION CO INC 4760 MURPHY CANYON RD SAN DIEGO, CA 92123 858-279-6122 Owner: AIR PRQDUCTS&CHEMICALS INC C/O J C SCHUMACHER CO 1969 PALOMAR OAKS WAY CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 1,560 0 1,560 0 A FS OG co (2- tSchmidt Fire ProtEEtilan Co., Inc. 4760 MURPHY CANYON RD • SAN DIEGO, CA 92123 • (858) 279-6122 • FAx (858) 279-3583 AIR PRODUCTS 1969 PALOMAR OAKS WAY CARLSBAD, CA 92009 (13) DRY CHEMICAL FIRE SUPPRESSION SYSTEMS . LAB HOODS APPROVED4SJSUBMITTED CARLSBA"IftfID-E .e4a etnofnllabon • cewd of cae 4irihle2 co/tn2o Kidde XVTM Control System f. fKidde Fire Systems Effective: March 2005 87-120099-001 87-027 - FEATURES Esthetically Pleasing Chrome Plating • Actuates Up to 20 Cylinders Rugged, Die-Cast Aluminum Body • Up to Four Micros witches Cylinder or Wall Mount • 24V Electrical Actuation Assembly Two Discreet Detection Lines . Tamper or Lock Port Between Cover and Backbox Up to 400 Feet Mechanical Detection Cable • Low Maintenance DESCRIPTION' The Kidde XVIM Control System is designed to enhance the quality and performance of Kidde pre-engineered sys- tems for commercial kitchen and industrial applications. De- veloped with the installer in mind, the XV offers several options, allowing field decisions to reduce the "installed cosr of a system. As a component of Kidde's inçiustrial dry chemi- cal and commercial kitchen systems offering, the XV pro- vides exceptional value, extreme versatility and excellent visibility. The XV ships ready to install. Included are three EMT con- nectors, a system valve actuator, two microswitches and two cartridges. It is ready to go with a basic installation pack- age. The Kidde XVControl System is UL Listed with WHDR Sys-' tem for commercial kitchen applications and UL Listed, FM approved for industrial applications. APPLICATIONS Applications for the XV Control Head System are multiple and varied, but typical functions would include: Commercial kitchens Automotive paint booths Industrial open-face spray booths Hazardous material storage facilities Liquid flammable storage areas Marine galleys Processes involving flammable liquids, such as dip tanks, containment areas, etc. TECHNICAL DATA VEHICLE SPRAY BOOTH ACTUATION Table 1. Mechanical Cable Parameters Table 4. Vehicle Spray Booth System Pressure Actuation Maximum Maximum Maximum Maximum Cable Line Cable Corner Detectors Tee Length Pulleys Pulleys Detection and 200 ft Manual Release- (61 in). 50 40 - to-trip Line 1 Detection and 200 ft. Manual Release- (61 m) 50 40 - to-hip Line 2 Pull-to-trip Remote 100 ft 30 Manual Release (30 m) Mechanical Gas 100 ft 30 - 1 Valve Release (30 rn) 'Tee pulley counts as hw corner pulleys. Maximum is from Control System, through tee pulley, to each device. WHDR SYSTEM PRESSURE ACTUATION Table 2. WHDR System Pressure Actuation Max. Total Max. # of Mm Max. 4 of Length of 114" Pressure Operating Extinguishing o.d. x .031" Switches (PIN Minimum Temperature System Wall High 486536) In Tubing Cylinders Pressure Actuation ILne Tubing, 0°F 12 106 ft. 2 (-17.8°C) (32 m) (1.5m) 0°F 20 91 ft 2 58. (.17.8°C) (28 m) (1.5 m) IND SYSTEM PRESSURE ACTUATION Table 3. IND System Pressure Actuation Max. Total Max. # of Mm. Max. # of Length of 114" Pressure Operating Extinguishing ed. x .031" Switches (PIN Minimum Temperature System Wall High 486536) in Tubing Cylinders Pressure Actuation iLne Tubing, -40°F 14 1668. 2 5 ft (-40°C) (51m) (1.5m) -40°F 20 121 2 5 ft (37 m) (1.5m) Max. # of Max. Total Length of 114" Max iof Min. Operating Extinguishing o.d. x .031" Pressure Swim (PIN Minimum Temperature System Wall High 486538) In 'Tubing Cylinders Pressure Actuation ILne Tubing, 0°F 20 140 ft. 2 (-17.8°C) (43 m) (1.5 m) 0°F ' 15 1608. 2 (-17.8°C) . (49 m) (1.5 m) 0°F 8 2008. 2 (-17.8°C) (61 m) (1.5 m) ORDERING INFORMATION Part Number Description Weight 87-120099-001 XV Control System includes: 16 lb. 1 ea. 87-120042-001 System Val* Actuator 1 ea. 87-120043-001 Syste'm Cartridge 1 éa. 87-120044-001 Test Cartridge 1 ea. 87-120058-001 EMT Connector Kit 2 ea. 87-120039-001 Microswitch Kit• 87-120042-001 System Valve Actuator '2 lb. 87-120043-001 System Cartridge 1 lb. 87-120045-001 High Pressure Hose for Cylinder Mount 1 lb 87-120044-001 Test Cartridge 1 lb. 87-120058-001 EMT Corrector Kit 1 lb., 87-120039-001 Microswitch Kit (SPD1) 1 lb. 83-100034-001 Electric Actuator Kit 2 lb. 87-120046-001 Valve Rebuild Kit 1 lb. 87-120047-001 Microswitch kit, SPDT 0.1 lb. 83-100035-001 Actuation Delay 4 lb. WHDR Systems designed and installed according to manual P/N 87-122000001. IND Systems designed and installed according to manual P/N 220423. Vehicle Spray Booth Systems designed and installed ac- cording to manual P/N 83-100036-001. Kidde XV is a trademark of Kidde-Fenwal, Inc. . This literature Is provided for Informational purposes only. KIDDE-FENWAL.INC. assumes no responsibility for the products suitability for a particular application. The product must be prop - arty applied to work correctly. If you need more Information on this product, or It you have a particular problem or question. contact KIDDE-FENWAL INC., Ashland, MA 01721. Telephone: (508) 881-2000 87-027 03/05 Kidde-Fenwal Inc. Printed in USA fKidde Fire Systems 400 Main Street Ashland, MA 01721 USA Tel: (508) 881-2000 Fax: (508) 881-8920 http:llwww.kiddefiresystems.com Industrial Dry Chemical fKiddeFire Systems S Cylinder and Valve Assembly . . Effective: April 2002 K-83-OO1 DESCRIPTION thecy1inder and valve assembly is equipped with a plated forged brass valve, pressure gauge, fusible plug relief de- vice, and a steel alloy cylinder shell. The cylinder conforms to DOT Specification 4BW-360. The assembly is pressur- . ized with Nitrogen to 360 PSIG (24.8 bar gauge) at 70°F (21.19C). The cylinder valve mates with a discharge adapter designed for use with Kidde® Pre-Engineered Fire Suppres- sion Systems. The cylinder valve is also designed to .a- •• •. cept any of the Pre-Engineered System control heads. yllndérNilve Model Part Number . Type of Powder Charge or Fill Weight of Powder (lb:) Nominal Diameter Overall Assembly Height Wall Mounting Bracket Part Number . A B In. In. 110-21 . 486573 ABC 21 9 17.6 486487 l'ID-25 486570 BC 25 . 9 17.6 486487 ' .I'ID-45 486574 ABC 45 . 9 30.8 445 I'ID-50 486571 BC 50 . 9 30.8 486488 ND-70 83-100018-00.1 ABC 68 12.3 30.2 87-100009-001 t'ID-75 83-100019.001 BC 75 12.3 30.2 87-100009-001 This literature is provided for informational purposes only. KlDDE-FENWAL.INC. assumes no responsibility for the product'ssuitability for a particular application. The product must be prop erly applied to workcorrectly. If you need more information on this product, or if you have a particular problem or question. contact KIDDE-FENWAL INC.. Ashland. MA 01721. Telephone: (508) 881.2000 K-83-001 04/02 . 02002 Kidde-Fenwal Inc. Printed in USA Kidde Fire Systems 400 Main Street Ashland, MA 01721 USA Tel: (508) 881-2000 Fax: (508) 881-8920 http://www.kiddefiresystems.com . ._..: Industrial Dry Chemical : fKiddeFireSrstems Mounting Bracket Kits . - . . . . . . Effective: April 2002 K.83-002 DESCRIPTION. . .• . . .. . A mounting bracket kit is used for mounting all cylinder and 1 . .. . valve assemblies. The kit consists of a steel bracket with a •. : "c" "D" •.. . shelf to hold .the cylinder bottom. A cylinder strap is used to I -L I secure the cylinder to the bracket. Prior to installation, en-, . •0• sure that the wall or other mounting surface will support the 0• • . recommended load specified in the table. Mount the bracket . . 3/8" FASTENING to the surface using three (3) 3/8-in. bolts or screws. HARDWARE (170 (3) WTC HOLES . FLEXIBLE V , 0 • 0YP .STRAP*\\ Mounting Bracket Part Number CylinderNalve Model Dimension A Dimension B . Dimension C Dimension D •• . Recommended Wall-Support Load in. in. 0 in. in. • lb. r 486487 IND-21 13.12 11.50 9.75 8.12 .65 ( IND-25 486488 IND-45 19.62 18.00 0 9.75 8.12 .. 130 1ND50 87-100009-001 lND-70 21.00 0 . 18.80 13.25 . 12.50 0 •.• 225 IND-75 S This literature is provided for informational purposes only. KIDDE.FENWAL,INC. assumes Kidde Fire Systems responsibility for the product's suitability for a particular application. The product must be prop- I 400 Main Street . any applied to work correctly. I Ashland, MA 01721 USA If you need more information on this product, or if you have a particular problem or question. I contact KIDDE-FENWAL INC., Ashland, MA01121. Telephone: (508) 881-2000 Tel:.(508) 881-2000 0 Fax (508) 881-8920 K-83-002 04/02 @2002 Kidde-Fenwal Inc. Printed in USA 0 http://www.kiddefiresystems.com Industrial Dry Chemical fKiddeFire Systems Discharge Adapter Kit Effective: April2002 - -------------- PIN 844908 DESCRIPTION The discharge adapter provides a means to connect 3/4" V NPT V. V .discharge pipe (or 1" pipe with a concentric reducer or re- ducing bushing) to any Industrial Dry Chemical cylinder and . .t . V. : valve assmebly.. The. discharge-adapter kit consists of a male, 3/4" NPT, brass discharge-valve-outlet adapter and a steel flange -plate for securing the discharge adapter to the valve outlet. FLANGE PTE ADAPTER . S This literature is provided for Informational purposes only. KIDDE-FENWALINC. assumes no Kidde Fire Systems I responsibility for the products suitability for a particular application. The product must be prop-I . 400 Main Street lerly applied to work correctly.'I Ashland, MA 01721 USA I If you need more information on this product, or if you have a particular problem or question. Icontact KIDDE-FENWAL INC.. Ashland, MA 01721. Telephone: (508) 881-2000 Tel: (508) 881-2000 Fax: (508) 881-8920 K-83-003 04/02 @2002 Kidde-Fenwal Inc. Printed in USA http:llwww.kiddefiresystems.com NOZZLE BODY ORFICE TIP NOZZLE BLOW-OFF CAP 06-250099-067 2.72 REF. .0 / Industrial Dry Chemical KiddeFire Systems Total-Flooding Nozzle Effective: April 2002 K312 P/N: 83-10000501 : :• x. DEScRIPTION. .. The Total-Flooding (TF) Nozzle is designed to uniformly dis- charge dry chemical throughout an enclosed volume. This . .. . . ... nozzle is to be mounted at ceiling level (unless otherwise . . .• listed) with the orifice tip pointed vertically down. The TF, Nozzle is also used to protect the work area volume for .. : open face spray booth applications and in automotive ye- . . . . hide spray booth applications. . . . . . Each TF Nozzle is factory-equipped with a blow-off cap to . . . . . . . .. . protect the nozzle orifices and prevent moisture buildup in . . . . . ... the discharge piping.. . . ~ 0 This literature is provided for Informational purposes only. KIDDE.FENWALINC. assumes no responsibility for the product's suitability for a particular application. The product must be prop- city applied to work correctly. If you need more Information on this product, or If you have a particular problem or question. contact KIDDE.FENWAL INC., Ashland. MA 01721. Telephone: (508) 881-2000 K-83-012 04/02 02002 Kidde-Fenwal Inc. Printed in USA Kidde Fire Systems 400 Main Street Ashland, MA 01721 USA TeI:.(508) 881-2000 Fax (508) 881-8920 http:/Iwww.kiddefiresystemscom Industrial Dry Chemical : fKiddeFire Systems . Fusible Link Housing Kit with FUsible Link .' Effective: April. 2002 K-83.014. ---- PIN: 804548 DESCRIPTION UL Listed and FM Approved Fusible Links are used in cor- .junction with the Fusible Link Housing Kit. The Fusible Links are held together with a low melting alloy, which melts at a predetermined temperature, allowing the two halves of the . . linktoseparate. .5 Fusible Links are available in various temperature ratings as shown in table. There are two temperature designations which apply to both fusible links and quartizoid bulb links. One temperature is called the rating temperature, and the other is called the maximum exposure temperature. CONNECTOR 1 3 Mi KNUT )% . . . (Not i ______ - A/16oABLETO CRIMP TYPE MLLINK ACTUATING DEVICE CABLE CONNECTOR 1!2 EMT LOCKNUT CONNECTOR \ . (Not Supplied). UqJLJu 1!16 CABLE TO ". ANOTHER DETECTORN CRIMP TYPE OR REMOTE MANUAL CABLE CONNECTOR CONTROL Fusible Link Rating Maximum Exposure Temperature Part Number Load Rating (lb.) OF OC OF OC Mm. Max. r 165 74 100 38 ( 282661 7 10 40 212 100 150. 65 282662 10 40 360 182 300 149 282664 10 40 500 260 440 .226 282666 10 40 I S This literature is provided for Informational purposes only. KiDDE-FENWAL.INC. assumes n Kidde Fire Systems o responsibility for the product's suitability for a particular application. The product must be prop- 400 Main Street lerly applied to Work correctly: I Ashland, MA 01721 USA I if you need more information on this product, or If you have a particular problem or question, I contact KIDDE.FENWAL INC., Ashland, MA 01721. Telephone: (508) 881.2000 Tel: (508) 881-2000 Fax: (508) 881-8920 K-83-014 04/02 02002 Kidde-Fenwal Inc. Printed in USA http://www.kiddefiresystems.com .0 1 . .. •. Industrial Dry Chemical Ar,iddeFire Systems Mechanical, Remote Manual Release . . .. . Effective: April 2002 K4321 - .. . ...., .. PIft 875572 . . . . . . :. . DESCRIPTIONS . .. . ...•• . . The Mechanical, Remote Manual Release is provided as a . . .. . . . . . . . . means of manually actuating the system from a remote : : . • location. The Mechanical, Remote Manual Release is attached to the primary control head with 1/16B cable. To, . S . . . . .. . ••. actuate the system through the Mechanical, Remote Manual . .. . : Release, pull out the ring pin and pull hard on the handle. . . . . .• . Each manual release is supplied with a separate name- . . . . . • .. .. . plate. This nameplate must be attached to the mounting . . . .. • .. .. . . surface 1" above or below the pull station. . . 0 • . .• . . . . An additional Mechanical, Remote Manual Release may be .. .. . • ••. installed with a Kidde® Tee Pulley (PIN 843791). : . •• . .. : ' This literature is provided for Informational purposes only. KIODE.FENWAL.lNC. assumes no responsibility for the products suitability for a particular application. The product must be prop- erty applied to work correctly. If you need more information on this product, or if you have a particular problem or question. contact KIDDE.FENWAI. INC.. Ashland. MA 01721. Telephone: (508) 881-2000 K-83-021 04/02 02002 Kidde-Fenwal Inc. Printed in USA Kidde Fire Systems 400 Main Street Ashland, MA 01721 USA TeI:(508) 881-2000 Fax: (508) 881-8920 http:llwww.kIddefiresystemscom Industrial Dry Chemical fKiddeFire Systems • Corner Pulley .' Effective: April 2002 K4325. PIN: 844648 DESCRIPTIONS The Corner Pulley is used to change the direction of the system cable runs. The cable's protective conduit (112 EMT) is attached to the corner pulley with the provided coupling • nuts. The ComerPulley is equipped with a ball-bearing pul- ley for minimum resitance to the cable travel COVER SCREW (16mm) VIA • ' •• ••• KkLth fl __ COUPLING : NUTS I 2- T E.M.T. CONNECTIONS COMPRESSION TYPE - 2.75 (70mm) APPROX. S Kidde Fire Systems I This literature Is provided for infoimationel purposes only. KIDDE-FENWAL.iNC. assumes no I responsibility for the product's suitability for a particular application. The product must be prop. 400 Main Street lc larty applied toworcorrecuy. I Ashland, MA 01721 USA • lit you need more Information on this product, or if you have a particular problem or question. I Tel: (508) 881-2000 • 1contact XIDDE.FENWAL INC.. Ashland, MA 01121. Telephone: (508) 881-2000 Fax: (508) 881-8920 • K-83-025 04/02 ©2002 Kidde-Fenwal Inc. Printed in USA http://www.kiddefiresystems.com MEA kADA 'q Helping People Take Actions' SERIES MT AND MT STROBE MULTITONE ELECTRONIC APPLIANCES S Description: Wheelock's Series MT and MT Strobe Multitone electronic appliances offer a choice of eight (8) nationally and internationally recognized alerting sounds: Horn, Bell, March Time Horn, Code-3 Tone, Code-3 Horn, Slow Whoop, Siren or Hi/La Tone. The Code-3 Horn and tone patterns are engineered to comply with NFPA/ANSI Temporal Pattern specifications without requiring additional equipment. With MT and MT Strobe appliances, one alarm appliance meets most of your signaling needs. The MT strobes can be synchronized using the Wheelock SM, DSM Sync Modules or the PS-1 2/24-8MP and PS-1 2/24-8CP Power Supplies with Wheelock's patented Sync Protocol. The MT Strobes are designed for ADA applications while meeting or exceeding the latest requirements of NFPA 72, ANSI 117.1, UFC and UL Standard 1971 as well as meeting ADA requirements concerning photosensitive epilepsy. Each MT and MT Strobe appliance has two installer selective sound output levels: STANDARD dBA and HIGH dBA. Non-strobe versions provide selectable voltage capability in one unit, I 2VDC or 24VDC. Strobe versions are specific for either I 2VDC or 24VDC and all models may be used with filtered or unfiltered (full-wave-rectified) input voltages. Separate input terminals are available, shunt wires are provided to enable both tone and strobe to operate simultaneously from a single input. The Series MT Multitone Strobe appliances are UL Listed for indoor wall mount applications under Standard 1971 for Signaling Devices for the Hearing Impaired and under Standard 464 for Audible Signaling Appliances. MT4-115-WH SERIES MT w/o STROBE For Weatherproof MTWP See Data Sheet S9004 Copyright 2005 Wheelock, Inc. All rights reserved. SERIES MT STROBE Features: Approvals include: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), New York City (MEA), Factory Mutual (FM) and Chicago (BFP) See approvals by model in Specifications and Ordering Information Designed to meet or exceed ADAJNFPNUFC/ANSI Standards and Accessibility Guidelines Complies with OSHA 29, Part 1910.165 Series MT appliances have IN and OUT wiring terminations that accept two #12 to #18 American Wire Gauge (AWG) wires at each terminal. Inputs are polarized for compatibility with standard reverse polarity type supervision One alarm appliance with (8) eight selective signals to provide superior sound penetration for various ambient and wall conditions with two field selectable sound output levels Code-3 Horn and Tone meetANSl/NFPA temporal pattern for standard emergency evacuation signaling Audible and strobe can operate from a single NAC circuit or from separate NAC circuits with any of the (8) eight audible sounds MT Strobe models are available with Wheelock's patented MCW Multi-Candela strobes with field selectable candela settings at 15/30/75/11 Ocd or with single candela 1575cd strobes. The strobes can be synchronized using Wheelock's sync modules or power supplies with built in Sync Protocol Selectable input voltage on non-strobe versions. Strobe versions are factory set for either 12 or 24VDC, with wide-Listed voltage range, filtered (DC) and FWR Mounts to either 4" square or double gang boxes (important for retrofit installations). Attractive flush or surface mounting No additional trimplate required for flush mounting 4 NOTE: All CAUTIONS and WARNINGS are identified by the symbol . All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPERAPPLICATION, INSTALLATION ANDIOR OPERATION OF THESE ,MJRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR ATH TO YOU AND/OR OTHERS. eneral Notes: Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range" (16-33v for 24VDC units and 8-17.5v for I2VDC units). Regulated Voltage Range is the newest terminology used by UL to identify the listed voltage range. All candela ratings represent minimum effective Multilane Strobe intensity based on UL Standard 1971. MT Strobe models are UL Standard 1971 Listed for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% ±2%. The MT-12/24, MTWP and MT4 models and listed for outdoor use at -31°F to 150°F (-35°C to 66°C) and maximum humidity of 95% (See Data Sheet S9004 or Installation Instruction Sheet P84150 for more detail on MTWP). MTWP and MT4 strobes are listed under UL 1638. MT Audible is UL Standard 464 Listed. Alarm Tones TONE ALARM TONES PATTERN DESCRIPTION HORN BROADBAND HORN (Continuous) BELL 1560 Hz MODULATED (0.07 sec. ON/Repeat) MARCH TIME HORN HORN (0.25 sec. ON!0.25 sec. OFF/Repeat CODE-3 HORN HORN (ANSI S3.41 Temporal Pattern) CODE-3 TONE 500 Hz (ANSI S3.41 Temporal Pattern) SLOW WHOOP 500-1200 Hz SWEEP (4.0 sec. ON/0.5 sec. OFF/Repeat) SIREN 600-1200 Hz SWEEP (1.0 sec. ON/Repeat) HLILO 1000/800 Hz (0.25 sec. ON/Alternate) P Table 1: dBA and Current Ratings for Multitone AudIble Portion RMS Current (amps) dBA © lOft (UL Reverberant) dBA © lOft (anechoic) dBA © lOft (UL Reverberant) 24 VDC 12 VDC 120 VAC 24 VDC 12 VDC 12 and 24 VDC 120 VAC HI Output STD Output HI Output SM output HI OtWt* SID Output HI 0utut Sf0 Output HI Output STD Output HI Output Sf0 Output HI Output STD Output @24 voc UL mae @24 voc UL max" @24 VDC UL max @24 voc UL max" UL max" UL max" Horn 0.074 0.108 0.033 0.044 0.145 0.176 0.023 0.034 0.060 0.042 92 87 1 90 77 99 93 88 82 BeD 0.040 0.053 0.018 0.024 0.077 0.095 10.014 0.020 0.041 1 0.039 86 80 85 69 92 87 82 1 75 March Time Horn 0.067 0.104 0.033 0.038 0.109 0.142 0.023 0.034 0.050 0.040 89 84 89 14 99 93 85 79 Code-3 Horn 0.069 0.091 0.026 0.035 0.100 0.142 0.023 0.034 0.050 0.042 88 83 88 73 99 93 85 75 Code-3 Tone 0.061 0.075 0.026 0.035 0.088 0.105 0.015 0.021 0.042 0.040 85 80 84 70 95 90 79 75 Slow Whoop 0.069 0.098 0.028 0.037 0.100 0.142 0.025 0.035 0.050 0.042 90 89 89 75 99 94 88 82 Siren 0.080 0.104 0.027 0.036 0.122 0.152 0.021 0.030 0.045 1 0.041 89 84 1 89 75 98 93 85 82 HIILO 0.044 0.057 1 0.020 0.026 1 0.089 1 0.114 0.018 0.026 0.042 1 0.039 1 86 1 81 1 86 1 71 93 88 1 82 79 Table 2: Strobe Current Ratings RMS Current (amps) Model MT-121575 MT.241575 MTWP-2475 ffl.24MCW Candela 1575cd 1575cd 180cd 15cd 30cd 75cd llocd @24VDC 0.152 0.060 0.094 0.041 0.063 0.109 0.140 UL max" 0.255 0.090 0.138 0.060 1 0.092 0.165 0.220 fl Note: If the strobe and audible operate on the same circuit, add the strobe current from Table 2 to the audible current from Table 1. * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (I6-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (I6v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. S Wiring Diagrams (for all models) MT SIGNAL AUDIBLE SIGNAL AND STROBE AUDIBLE SIGNAL AND STROBE OPERATE INDEPENDENTLY OPERATE IN UNISON. RED AND _______________ BLACK SHUNT-WIRES ARE FROM Fu + _______________ Nona SUPPLIED. PRECEDING + + TONGCY PUECRE APPUM4CE.EOLM PS.1224'. FN= PRECOM + TO NEXT StAWK EOLR _ FROM PS-12G41# ___________ AWII. ___________________ PRECEDING IMR + APPLLN4CE OR RI0 - T - POWER ______________________ IT APPLIANCE SUPPLIES ___ SIGNAL - - - OR FACP I1.t9. APPLIANCE FACP POWRIES __ - OR EOLR STROBE AUDIBLE ,,00u u0ae Specifications and Ordering information Model Number Order Code Input Voltage Rated Candela Mounting Options' Agency Approvals UL MEA CFM FM BFP MT-12124-R 5023 12/24 - D,E.F,L.M.O,P.R X X X X X MT-12/24-W 5024 12/24 - D,E.F,L.M,O.P,R X X X X X MT-241575W-FR 8422 24 15 (75 on AXIS) D,E,F,L,M,O,P,R X X X X * MT-24MCW-FR 3301 24 15/30175/110 D,E,F.L,M,O,P,R X MT-24MCW-FW 3303 24 15/30175/110 D.E,F,L,M.O,P,R X * X * * MT-121575W-FR' 8421 12 15 (75 on AXIS) D.E.F,L,M,O,P.R X X X x MT-121575W-NW 9747 12 15 (75 on AXIS) D.E.F,L.M.O.P.R X X X X * MTWP-2475W-FR°° 8420 24 180 @ 77°F (25°C) M X X X X * MTWP-2475W-NW** 9744 24 180 @ 77°F (25°C) M X X X X ° MT4-115-R 6223 120 VAC - D. E, J, K. N. 0, R X X X X X MT4-115-S 6142 120 VAC - D, E, J, K. N. 0, R X X X X X MT4115WHVFRN 6224 120 VAC 15 D. E. J, K. N, 0, R X X X X X MT4-12/24-R 5308 12/24 - D. E. J, K, N, 0, R X * * * MT4-12/24-S 7997 12/24 - D, E, J, K, N, 0, R X * *Pending NOTE: °°M1WP-2475W is Weatherproof and rated for 180 Cd @ 77°F (25°C). See Data Sheet S9004 or Installation Instruction P84150. °°°For additional information on mounting please refer to Data Sheet S7000. # 1575 strobes are UL Listed for 15cd with 75cd on AXIS. ## Series WH Strobe is listed for UL Standard 1638 only. See Instruction Sheet P83160. AkWARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" P82467 MT-12/24, P84155 MT wl Strobe P84150 MTWP WEATHERPROOF "GENERAL INFORMATION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS DO UNDERGO PERIODIC CHANGES, IT IS IMPORTANT ThATYOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: TOTAL CURRENT REQUIRED BYALLAPPUANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR RATED INPUT VOLTAGE RANGE. INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. USE STROBES ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBE ON CODED OR INTERRUPTED CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBE MAY NOT FLASH. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, S maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). Architects and Engineers Specifications The notification appliance shall be a Wheelock Series MT audible/visual appliance or equivalent. Notification appliance shall be electronic and use solid state components. Electromechanical alternatives are not approved. Each electronic appliance shall provide eight (8) field selectable alarm tones. The tones shall consist of: HORN, BELL, MARCH TIME HORN, CODE-3 HORN, CODE-3 TONE, SLOW WHOOP, SIREN and HI/LO. Tone selection shall be by durable dip switch assembly and not clips or jumpers. The Multitone Audible appliance shall be UL Listed under Standard 464 for Audible Signal Appliances. The audible and the strobe shall be able to operate from a single NAC circuit while producing any of these tones. The appliance shall provide two output sound levels: STANDARD and HIGH dBA. The HIGH dBA setting shall provide a minimum 5 dBA increase in sound output at nominal voltage. The HIGH anechoic dBA measurement at 10 feet at the alarm HORN SETTING shall be 99 dBA minimum. Operating voltages shall be either 12 VDC or 24 VDC using filtered power or unfiltered power supply (full-wave-rectified). All models shall have provisions for standard reverse polarity type supervision and IN/OUT field wiring using terminals that accept #12 to #18 AWG wiring. Combination audible/visual appliances shall incorporate a Xenon flashtube enclosed in a rugged Lexan lens or equivalent with solid state circuitry. Strobe shall produce a flash rate of one (1) flash per second minimum over the voltage range. The MT strobe intensity shall be rated per UL and Listed under Standard 1971 for Signaling Devices for the Hearing Impaired for 1575cd multi-candela with field selectable 15/30/75/110 candela settings. The 1575 candela strobe shall be specified when 15 candela or with 75 candela intensity on-axis is required. Strobe Models shall incorporate circuitry for synchronized strobe flash and shall be designed for compatibility with Wheelock SM and/or DSM Sync Modules or Wheelock's Power Supplies with Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the module fails to operate (i.e., contacts remain closed), the strobes shall revert to a non-synchronized default flash rate. Strobe activation shall be via independent input or from the same input circuit as the audible. The combination audible/visual appliances shall be installed indoors and may be surface or flush mounted. They shall mount to standard electrical hardware requiring no additional trimplate or adapter. The aesthetic appearance shall not have any mounting holes or screw heads visible when the installation is completed. The appliance shall be finished in a textured red color. The Series MT-12/24, MTWP and MT4 appliances may be installed indoor or outdoor with the proper back box. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. WE SUPPORT AND ENCOURAGE NICET CERTIFICATION ASSEMBLED IN THE USA 3 YEAR WARRANTY National Sales Office 800-631-2148 Canada 800-397-5777 E-Mail: lnfo@wheelockinc.com http://www.wheelockinc.com Distributed By: 273 BRANCHPORT AVENUE • LONG BRANCH, NJ 07740 • TEL: 732-222-6880 • FAX: 732-222-2588 S200002/05 Industrial Dry Chemical introduction Chapter 1. Introduction 1-1 INTRODUCTION The Kidde Industrial Fire-Protection System is a pre-engi- neered, dry-chemical fire-suppression system. The system pro- vides fire protection using dry-chemical agents in accordance with NFPA Standard 17, "Standard for Dry Chemical Systems, and, except where noted, all of the variations specified in this Manual are listed by Underwriters' Laboratories and approved by Factory Mutual System Research Corp. - 1-2 MANUFACTURER'S WARRANTY Seller warrants that this product will, under normal use and ser- vice, be free from defects in material and workmanship for a period of one (1) year from the date of original sale. Seller agrees, upon written notice from end user, given no later than thirty (30) days after the defect is discovered, to repair or replace, at the Sellers option, any part which after examination by Seller is dis- closed to have been defective, provided that such product is re- turned to Seller, transportation charges prepaid, during the warranty period. This warranty does not apply to any damage resulting from accident, improper installation, alteration, misuse or abuse. The full extent of Seller's warranty obligations are to repair or replace any defective part. THERE ARE NO OTHER WARRANTY OBLIGATIONS OF SELLER, INCLUDING ANY WARRANTY OF MERCHANTABIL- ITY OR FITNESS FOR A PARTICULAR PURPOSE, EITHER EXPRESSED OR IMPLIED. The warranty for items not manu- factured by Seller is limited to the warranty obligations of Seller's suppliers and shall be subject to performance of such warranty obligations by the suppliers. SELLER IS NOT LIABLE FOR ANY OTHER COSTS, LABOR CHARGES, DELAYS OR CLAIMS NOR FOR ANY CONSE- QUENTIAL, CONTINGENT OR INCIDENTAL DAMAGES WITH RESPECT TO THE PRODUCT OR ITS USE. Seller neither assumes or authorizes any person to assume for it any other obligation or liability in connection with this product. Before proceeding with any Kidde system design, installation, or maintenance procedure, the requirements of this manual must be fully understood. Components not described in this manual are not recognized by Kidde Fire Systems as system compo- nents and must NOT be used in the Industrial Dry Chemical Sys- tem. The Kidde Industrial Dry Chemical Fire-Suppression system is to be installed, inspected and maintained by a Kidde Fire Systems Authorized distributor, and in accordance with NFPA 17, Standard for Dry Chemical Extinguishing Systems, NFPA 33, Standard for Spray Applications Using Flammable Com- bustible Materials, and this manual. 1-3 KIDDE INDUSTRIAL.. FIRE-SUPPRESSION SYSTEMS The Kidde Industrial Fire-Suppression System is a fixed dry- chemical system consisting of a supply of dry chemical stored in one or more cylinder-and-valve assemblies. Each cylinder is equipped with an actuation device, which may be mechanically, electrically, or pneumatically activated. Automatic actuation is usually initiated by heat detectors that. are located in the hazard area. Upon activation, the dry chemical is discharged through fixed piping and nozzles positioned through- out the protected area. 1-3.1 System Types Fixed dry-chemical systems are of tiVo types: total-flooding and local-application. In total-flooding, a predetermined amount of dry chemical is die- charged through fixed piping and nozzleC Into an encloSed spack. or enclosure around the hazard. Total-flooding is applicable only when the hazard is totally enclosed or when all openings sur- rounding a hazard can be closed automaticallywhenthe system is discharged. Total-flooding can be used only where no re-igni- tion is anticipated because the extinguishing action is transient. Local application differs from total-flooding in that the nozzles are arranged to discharge directly into the fire. Local application is practical in those situations where the hazard can be isolated from other hazards so that fire will not spread beyond the area protected, and where the entire hazard can be protected. The principal use of local application systems is to protect open tanks of flammable liquids. As with total-flooding systems, local appli- cation is ineffective unless extinguishment can be immediate and there are no re-ignition sources. 1.4 DRY-CHEMICAL FIRE SUPPRESSION Dry chemical is a mixture of powders that is used as a fire- extinguishing agent. The Kidde industrial system uses sodium- bicarbonate-base dry chemical (termed "regular dry chemical") for Class-13 (flammable liquid) and Class-C (electrical equip- ment) fires and monoammonium-phosphate base (termed "multi-purpose dry chemical") for Class-A (ordinary combus- tibles), Class-B, and Class-C fires. The dry chemicals used in the Kidde industrial system are stable at both low and high temperatures. Various additives are mixed with the base mate- rials to improve their storage, flow, and water-repellency char- acteristics. The upper storage temperature limit for the system is 120 degrees F (49 degrees Q. The lower temperature limit is -40 degrees F (40 degrees Q. UL EX-2153 . 1-3 November 1998 Introduction Industrial Dry Chemical The mixtures of powders used in dry-chemical extinguishing agents are non-toxic. However, the discharge of large amounts .of dry chemical may cause temporary breathing difficulty during and immediately after discharge and may cause serious visibil- ity problems. 0 After discharge, the dry chemical should be removed from any valu- able equipment to prevent a possible reaction between materials in the presence of moisture. Personnel in contact with the agent should remove the dry chemical from their skin with tap water. 1-5 EXTINGUISHING PROPERTIES Regular (BC) dry chemical is highly efficient in extinguishing tires in flammable liquids. It can also be used on fires involving some types of electrical equipment, such as turbine generators, oil- filled circuit breakers, and transformers. Multi-purpose (ABC) dry chemical can be used on fires involving flammable liquids, ener- gized-electrical-equipment fires, and on fires in ordinary combus- tible materials. When multi-purpose (ABC) dry chemical is discharged onto burn- ing ordinary combustibles, the decomposed monoammonium phosphate leaves a sticky residue on the burning material. This residue seals oxygen from the glowing material, thus extinguish- ing the fire and preventing re-ignition. Multi-purpose (ABC) dry chemical seldom needs the help of wa- ter to completely extinguish fires in Class-Arnatenals. However, multi-purpose dry. chemical is not effective on Class-A deep seated or burrowing fires. When introduced into the combustion zone, dry chemical causes almost immediate flame extinguishment. Smothering, cooling, and radiation shielding contribute to the extinguishing efficiency of dry chemical, but the principal mechanism for the flame extin- guishment is the chemical chain-breaking properties of the dry chemicals. The chain-reaction theory of combustion assumes that free radi- cals are present in the combustion zone and that the reactions of these species with each other are required for continued burn- ing. The discharge of dry chemical into the flame prevents reac- tive particles from interacting and continuing the combustion chain reaction, and thus extinguishes the flame. Dry-chemical systems are used in situations where fast ektin- guishment is desired and where re-ignition sources are not present For example both regular and multipurpose dry-chemi, cal systems are used primarily for flammable liquid fire hazards such as dip tanks, flammable liquid storage rooms, and areas where flammable liquid spills may occur. Since dry chemical is electrically non-conductive, extinguishing systems using this agent can be used on electrical equipment that is subject to flammable liquid fires such as oil-filled circuit breakers. Dry-chemical system protection is not recommended, however, for delicate electrical equipment, such as telephone switchboards and electronic computers. Such equipment is sub- ject to damage by dry chemical deposit and, because of the in- sulating properties of the dry chemical, may require excessive cleaning to restore operation. 1-6.1 Fixed Systems Fixed systems containing multi-purpose (ABC) dry chemical are suitable for the prptection of ordinary combustibles, provided that , the dry chemical can reach all the burning surfaces. Dry-chemi- cal systems should not be used for applications involving corn-. bustible metals such as sodium, potassium, and magnesium or for chemicals which contain their own oxygen supply. Systems should also not be designed for Class-A applications in which there is the possibility that deep-seated fires will result, prevent- ing dry-chemical access to all burning surfaces. :1-7 SYSTEM TESTING Fire and operational tests were run by discharging dry chemical through all of the nozzles listed in this manual. The discharge from each nozzle was collected and weighed to determine uni- formity of nozzle discharge. Fire extinguishing tests were run at minimum (40 degrees FI40 degrees C), normal, and maximum (120 degrees F149 degrees C) storage temperatures of the sys- tem, together with minimum and maximum pipe lengths and pipe equivalent lengths. These tests determined the effectiveness of the system. Cycle tests were run on all components to deter- mine their operational reliability and safety. 1-6 USES AND LIMITATIONS OF DRY-CHEMICAL SYSTEMS Regular (BC) dry chemical is primarily used to extinguish flam- mable-liquid surface fires. Because it is electrically non-conduc- tive, it can be used on flammable-liquid fires involving live electrical equipment. Due to the rapidity with which it extinguishes flame, multi-purpose (ABC) dry chemical is used on surface fires involv- ing Class-A (ordinary combustible) materials. It is important to recognize that dry chemical is considered to be a transient extinguishant and does not produce a lasting inert atmosphere above the surface of a flammable liquid, nor does it maintain a total-flooding concentration in an enclosed space. Con- sequently, its use will not result in a permanent extinguishment if re-ignition sources, such as hot metal surfaces or persistent elec- trical arcing, are present. UL EX-2153 14 November 1998 S Industrial Dry Chemical Component Descnptlons S Chapter 2 Component Descriptions Contents Paragraph. Title. Page: 2-1 .... Cylinders and Mounting Hardware...................................................................................................................2-3 2-1.1 Cylinder-and-Valve Assemblies ................................................................ .............................................................. 2-3 2-1.2 Mounting Bracket Kits ..........................................................................................................................................2.4 2-1.3 Discharge-Adapter Kit, P/N 844908 .................................... . ........................................ .................. .............. . ......... 2-4 2-2 •. Control Heads ...............................................................................................................2-5 2-2.1 Mechanical Control Head(s), P/Ns 486607, 899063, and 899176 .................................................. .................... 2-5 2-2.2 Electric Control Head, PIN 899175 ......................................................................... ............................................... 2-5 2-2.3 Pneumatic Control Head, P/Ns 899083 and 899088 ........ ..................................................... . ............................. 2-5 2-2.4 Pneumatic Control Head, P/N 899087 ................................................................................................................... 2-6 2-2.5 Tandem Control Head, P/N 899082 .............................................................................................. . ........................ 2-6 2-3 Discharge Nozzles ............................................................................................................ ...... .................................. 2-7 2-3.1 . Local-Application Nozzles .......................................................................................... . ................ . ......................... 2-7 2-3.2 . . Total-Flooding Nozzle, PIN 83-100005-001 .........................................................................................................2-7 2-3.3 . Duct/Plenum (DP) Nozzle, PIN 83-100006-001 ...................................................................................................2-8 2-4 Automatic Detectors and Accessories .................................................................................... ........... . ................. 2-8 2-4.1 Fusible-Link Housing Kit, P/N 804548 .... ......................................................................................................... ... 2-8' 2-4.2 Fusible Links (Model ML), P/Ns 282661, 282662, 282664, and 282666 ........ ....................................................... 2-8. 2-4.3 Quartzoid-Bulb Link, P/N 260527 ................................................................................................ . .......................... 2-8 2-4.4 Fusible-Link Housing Kit .......................................................................................................................................2-9 2-4.5 Thermo-Bulb Fusible Links ..................................................................................................................................2-9 2-5 Thermostats ................................................................................................................. ... ....................................... 2-9 2-5.1 Thermostats .................................................................................................................................... . ........................ 2-9 2-5.2 . Pneumatic Heat Detector (HAD), P/N 840845 ................................................................................... . ..... ............. 2-10' 2-5.3 Mercury Check, P/N 871346....... ................................................................................................................... . ...... 2-10 2-5.4 Heat Collector, P/N 31272 ................................................... ................................................................................ 2-10• 2-6 Manual Release Stations .......................................................... . .................. ........................ ...............................2-11 2-6.1 Mechanical, Remote Manual Release, P/N 875572 ...... .... .......................................... ............. ............................ 2-11 2-6.2 . Pressure Operated Release, P/N 874290 .... . ....................................... . ......................... . .................................... 2-11 2-7 Main/Reserve System .. Components ................................................................................. ................ ................... 2-11 2-7.1 Two-Way Check Tee, P/N 896516 ......................................................................... . ............................................ 2-11 2-7.2 Main-to-Reserve Transfer Switch, P/N 802398 ..................................................................................................2-11'. 2-7.3 Pneumatic Main-to-Reserve Transfer Valve, PIN 871364 ............................................ ....................................... 2-12 2-8 Auxiliary Components .............................................................................................. ............ .............. . ....................... 2-12. 2-8.1 Corner Pulley, P/N 844648 .................................................................................................................................... 2-12 2-8.2 Tee Pulley, PIN 843791 ............................................... . .................................................................. . ............. ........ 2-13 2-8.3 1/16" Cable, P/N 219649 ............................................................................................................. . .......................... 2-13.' 2-8.4 Crimping Tool, P/N 253538 ............................................... . .................................. . ......... . ... .................................2-13 2-8.5 ' System Recharge ................................................................................................................................................2-13 UL EX-2153 ' 2-1 '. November 1998 0 ULEX-2153 2-2 November 1998 .4. P.4 W . Figure 2-1. Cylinder-and-Valve Assembly Industrial Dry Chemical Component Descriptions -. Chapter 2 Component Descriptions• : 2.1 CYLINDERS AND MOUNTING HARDWARE : 2-1.1 Cylinder-and-Valve Assemblies Table 2-1 outlines the specific information for each cylinder-and- valve assembly model. Each cylinder-and-valve assembly must be installed in an upright position using the mounting bracket specified in Table 2-2. Each cylinder-and-valve assembly will also • utilize a discharge adapte P/N 844908. The cylinder-and-valve assembly is equipped with a forged brass valve, pressure gauge, fusible plug relief device, and a steel-alloy cylinder shell. The cylinder conforms to DOT Specification .48W- 360. The assembly is pressurized with Nitrogen to 360 psig (24.8 bars) at 70 degrees F (21.1 degrees Q. The cylinder valve mates with a discharge adapter designed for use with Kidde pre-engi- neered fire-suppression systems. The cylinder valve is also de- signed to accept any of the pre-engineered system control heads. WARNING PROTECTIVE EYEWARE MUST ALWAYS BE WORN WHEN WORKING WITH PRESURIZED CYLINDERS. NEVER SERVICE THIS CYLINDER-AND-VALVE AS- SEMBLY UNLESS THE ANTI-RECOIL PLATE-(PIN 255096) AND SHIPPING CAP (PIN 255096) ARE IN. STALLED. Table 2-1. Cylinder-and-Valve Assemblies Cylinder! Valve Model Part Number (PIN) Type of Powder Charge or Fill Weight of Powder (lbs.) Nominal Diameter (in.) Overall Assembly Height Wall- Mounting Bracket . PIN lND-21 486573 ABC 21 9 17.6 486487 lND-25 486570 BC 25 9 17.6 486487 7 IND-45 486574 ABC 45 9 30.8 486488 IND-50 486571 BC 50 9 30.8 486488 IND-70 83-100018-001 ABC 68 12.3 30.2 8-100009-001 lND-75 83-100019-001 BC 75 12.3 30.2; 87-100009-001 UL EX-2153 2-3 November 1998 Is NPT PLATE Figure 2-3. Discharge Adapter Kit, P/N 844908 Component Descriptions 24.2 Mounting Bracket Kits . A mounting bracket kit is used for mounting all cylinder-and-valve assemblies The kit consists of a steel bracket with a shelf to hold the cylinder bottom. A cylinder strap is used to secure the cylinder to the bracket. Prior to installation, ensure that the wall or other mounting surface will support the recommended load specified in Table 2-2. Mount the bracket to the surface using three (3)3/8-in, bolts or screws. NOTE: For floor mounting of lND-70 or IND-75 cylinders, an accessory floor-mounting kit (P/N 87-100010-061) may be used. This is attached to the vertical mounting bracket. Industrial Dry Chemical 2-1.3 Discharge-Adapter Kit, PIN 844908 The discharge adapter provides a means to connect 3/4" dis- charge pipe (or 1" pipe with a concentric reducer or reducing bushing) to any IND cylinder-and-valve assembly. The discharge-adapter kit consists of a male, 3/4" NPT, brass, ,discharge-valve-outlet adapter and a steel flange plate for se- curing the discharge adapter to the valve outlet. NOTE: Nuts and bolts usedto secure the anti-recoil plate to the discharge valve should be retained and used for• mounting the discharge adapter to the valve outlet. NOTE: -The discharge adapter can also be used as a recharge adapter to pressurize the cylinder with nitrogen after H4 with dry chemical. 3/8 FASTENING .406 DIk TRU - HARDWARE (TO (3) wc HOLES FLEXIBLE \ WALL) STRAP \ I __ Figure 22. Mounting Bracket Kit Table 2-2. Mounting Bracket Kits Mounting.• For Dimension Dimension Dimension Dimension Recommended Bracket CylinderNalve A B • C D Wall-Support PIN • Model (in.) (in.) (in.) (in.) Load (lbs.) k. 486487 • 13.12 11.50 9.75 8.12 • 65 486488 19.62 18.00 9.75 8.12 130 87-100009-001 . 21.09 18.80 13.25 12.50 225 UL EX-2153 2-4 November 1998 Industrial Dry Chemical Component- Descriptions o 2-2 CONTROL HEADS 2-2.1 Mechanical Control Head(s), P/Ns 486607, 899063, and 899176 The mechanical control head is used in systems equipped with fusible-link detectors. When a fusible-link detector operates, the release of tension in the fusible-link cable allows the control head to actuate. A spring-loaded plunger depresses the check stem in the cylinder valve, discharging the contents of the cylinder. The èontrol head also releases tension in a cable to an optional tan- dem control head, causing operation of this device. The control head is equipped with a local manual-release handle integral with the control-head cover plate. To manually operate the sys- tem locally, pull the ring pin out and rotate the handle clockwise. A mechanical, remote manual release may also be used with the mechanical control head. PIN 486607 does not have a microswitch. P/N 899063 is equipped with one Form-C microswitch. P/N 899176 is equipped with two Form-C microswitches. The microswitch contacts in both control heads transfer when the control head operates. See Chapter 5 for microswitch contact ratings. CAUTION THE CONNECTION TO FUSIBLE-LINKS, REMOTE MANUAL PULL, AND THE TANDEM CONTROL HEAD SHALL ONLY BE MADE THROUGH THE CONTROL HEAD PORTS SHOWN IN FIGURE 241. CONNECTION TO OTHER-TYPE DEVICES IS NOT AUTHORIZED. RELEASE -BACK PLATE OPENING ALTERNATE (LOW PROFILE) TO FUSIBLE TO TAN TO REMOTE HEAD OR FUEL MANUAL PULL DEM CONTROL ONLY LINKS ONLY SHUTOFF VALVE ONLY ACTUATOR LEVER ACTUATING CAM OWN IN SET POSITION Figure 2-4. Mechanical Control Head, P/N 486607 (No microswitch - Shown with cover removed) 2-2.2 Electric Control Head, PIN 899175 The electric control head is used in systems that use thermo- stats. The control head is rated at 120 VAC, 10 amps nominal, or 24 VDC, 2 amps nominal. When electric power is applied to the control head, a solenoid releases a spring-loaded plunger which depresses the check stem in the cylinder valve, discharging the contents of the cylinder. The control head also releases tension in a cable to an optional tandem control head, causing operation of this device. The con- trol head is equipped with a local manual-release handle integral with the control-head cover plate. To manually operate the sys- tem locally, pull the ring pin out and rotate the handle clockwise. A mechanical, remote manual release may also be used with the electric control head. P/N 899175 is equipped with two Form-C microswitches. The microswitch contacts in the control head transfer when the con- trol head operates. One set of contacts, which is normally dosed when the control head is in the set position, must be wired in series with the control-head solenoid coil to disconnect the power from the coil upon actuation. Refer to Chapter 5 for microswitch contact ratings. CAUTION -ALL SYSTEMS WITH ELECTRIC ACTUATION MUST BE PROVIDED WITH A CONTINUOUS, SUPERVISED BACKUP POWER SOURCE CAPABLE OF OPERAT- ING THE SYSTEM FOR AT LEAST 24 HOURS, UN- LESS THIS REQUIREMENT IS EXPLICITLY WAIVED BY THE AUTHORITY HAVING JURISDICTION. TO FUSIBLE R8EASEUNKACE BACK PLATE UNK ONLY . p..(TO SET ROTATE SLENOIOAPEMTURE SWDRIV 11U OPENING IN BAOC. PLATE AND DEPRESS SOWlO10APEA1uRE ACTUATOR LEVER Figure 2-5. Electric Control Head, P/N 899175 (Shown with cover removed) CAUTION THE CONNECTION TO REMOTE MANUAL PULL AND TANDEM CONTROL HEAD SHALL ONLY BE MADE THROUGH THE CONTROL HEAD PORTS SHOWN IN FIGURE 2-12. CONNECTION TO OTHER. TYPE DEVICES IS NOT AUTHORIZED. 2-2.3 Pneumatic Control Head, P/Ns 899083 and 899088 The pneumatic control head is used in systems that use up to four pneumatic, rate-of-rise, heat-actuated devices (HADs). In the rate-of-temperature rise principle, it is a rapid increase in temperature, resulting in a rapid pressure increase in a detec- tion-system network consisting of HADs, the pneumatic control head, and tubing, that causes the system to actuate. The HADs are connected to the control head by 1/8-inch copper tubing. When air within an HAD is heated by a fire in the pro- tected space, it expands and increases the pressure within the detector. This pressure increase is transmitted through the cop- per tubing to the pneumatic control head. When sufficient pres- sure has rapidly been built up in the entire detection-system network (HAD's, pneumatic control head, and tubing) a pressure- sensitive diaphragm in the control head's sensing chamber trips the control head's release linkage. This, in turn, releases a spring- loaded plunger which depresses the check stem in the cylinder valve and discharges the contents of the cylinder. The pneumatic control head is fitted with a vent so that small changes in pressure in the detection-system network, resulting from normal changes in temperature in the protected space, can be vented to atmosphere. However, if pressure builds up faster than it can be relieved by the vent, the pneumatic control head will actuate. This is the principle of rate-of-rise operation. UL EX-2153 2-5 November 1998 Component Descriptions The sensitivity of the pneumatic control head is given in terms of .the pressure differential required to trip the control-head release linkage, and this pressure differential is measured in inches of water. Pneumatic control heads used for industrial applications are set to activate at a pressure differential of 4 inches of water. The vent size is measured in terms Of seconds, and the number of seconds indicate the time required for a 3-inch (water column, w.c.) pressure differential in the control head's sensing chamber to drop 2 inches (i.e., from 3 inches w.c. to 1 inch w.c.). The larger the vent size in seconds, the faster the control head will respond to temperature changes. Pneumatic control heads for industrial systems that are connected directly to HAD's use a vent size of 5 seconds. Upon actuation, the pneumatic control head also releases ten- sion in a cable to an optional tandem control head, causing op- eration of this device. The control head is equipped with a local manual-release handle integral with the control-head cover plate. To manually operate the system locally, pull the ring pin out and rotate the handle clockwise. A mechanical, remote manual re- lease may also be used with the pneumatic control head. VENT PLUG CHAMBER DIAPHRAGM CONNECTER FOR PNEUMATIC TUBING FROM REMOTE 1I 1$l TO MANuAL. w.—r1l I Li 4.V-lIIb- TANDEM CONTROL HEAD ONLY S . ACTUATOR Figure 2-6. Pneumatic Control Head, P/N 899083 (Shown with cover removed) CAUTION THE CONNECTION TO REMOTE MANUAL PULL OR TANDEM CONTROL HEAD SHALL ONLY BE MADE THROUGH THE CONTROL HEAD PORTS SHOWN IN FIGURE 2-13. CONNECTION TO OTHER-TYPE DE- VICES IS NOT AUTHORIZED. 2-2.4 Pneumatic Control Head, PIN 899087 The pneumatic control head, PIN 899087, is used in systems that have between 5 and 12 pneumatic, rate-of-rise, heat-actuated devices (HAD's). These systems use a mercury check, P/N 871346, to isolate the pneumatic tubing branch lines from each other in order to maintain the proper detection system response characteristics. The mercury check is also the interface between the pneumatic detection system (tubing and HAD's) and the pneumatic control head. The HAD's are connected to the mercury check by 1/8-inch cop- per tubing. When air within an HAD is heated by a fire in the protected space, it expands and increases the pressure in the detector. This pressure increase is transmitted through the cop- per tubing to the mercury check, and from the mercury check to the pneumatic control head. When sufficient pressure has been S rapidly built up in one detection system branch (HAD's, tubing line, mercury check, and pneumatic control head), a pressure- sensitive diaphragm in the control head's sensing chamber trips Industrial Dry Chemical the control head's release linkage. This, in turn, releases a spnng- loaded plunger, which depresses the check stem in the cylinder valve and discharges the contents of the cylinder. Thepneumaticcontrd head, P/N 899087, is set to activate ata pies- sure differential of 4 inches of water; and has a vent size of 40 sec- onds. Upon actuation, the pneumatic control head also releases tension in a cable to an optional tandem control head, causing op- eration of thià device. The control head is equipped with a local manual release handle integral with the control-head cover plate. To manu- ally operate the system locally, pull the ring pin out and rotate the handle dockwise. A. mechanical, remote manual release may also be used with the pneumatic control head. P/N 899.087 is equipped with one Form-C microswitch. The microswitch contacts transfer when the control head operates. See Chapter 4 (Installation) for the microswitch contact ratings. SENSING VENT PLUG CHAMBER . DIAPHRAGM CONNECTOR FOR b PNEUMATLC1UBB1G' FROM REMOTE TANDEM CONTROl. MANUAL PULL. NEAP ONLY STATION ACTUATOR CAM Figure 2-7. Pneumatic Control Head, P/N 899087 (Shown with cover removed.) Use with mercury check, P/N 871346. CAUTION THE CONNECTION TO REMOTE MANUAL PULL OR TANDEM CONTROL HEAD SHALL ONLY BE MADE THROUGH THE CONTROL HEAD PORTS SHOWN IN FIGURE 2-14. CONNECTION TO OTHER-TYPE DE- VICES IS NOT AUTHORIZED. 2-2.5 Tandem Control Head, PIN 899082 The tandem control head is used on multiple-cylinder installa- tions. A primary control head, which may be mechanical, electric, or.pneumatic, is attached to one cylinder valve. Each additional cylinder is equipped with a tandem control head. Release of cable tension from the primary control head actuates the tandem con- trol head(s), operating all cylinder valves simultaneously. The tandem control head is not equipped with an integral manual- release handle or microswitch contacts. There is no limit to the number of tandem control heads that may be used. However, there is a maximum of 30 corner pulleys and 100 It. (30.4 m) of cable between the primary and last tandem control head. NOTE: An alternative method may be used to actuate multiple cylinders in large applications. This alternative method uses the KRS-100 or KRS-700S releasing systems. Refer to Kidde Fire Systems manual P/N KRS100-001 for specific details regarding the KRS-00 actuation system, or to manual P/N 415830 for details of the KRS- 700S actuation system. UL EX-2153 2-6 November 1998 4 •2.00lN. . Industrial Dry Chemical Component Descriptions.-,•. AcuAToRLRtf , ,4.RATcIET5PCOL O i r I. ELECmCAL CR tw WAD! OW SINTIMMIM It l'& LK (!Is AXIIA"M CRIuIuEvoumolq Figure 2-8. Tandem Control Head, PIN 899082 (Shown with cover removed) CAUTION THE CONNECTION TO MECHANICAL, ELECTRICAL, PNEUMATIC, OR TANDEM CONTROL HEADS SHALL ONLY BE MADE THROUGH THE CONTROL PORTS SHOWN IN FIGURE 2.8. CONNECTION TO OTHER-TYPE DEVICES IS NOT AUTHORIZED. 2-3 DISCHARGE NOZZLES 2-3.1 Local-Application Nozzles There are two types of nozzles used for local-application sys- tems; overhead and tankside. Overhead nozzles are designed to discharge a solid cone of dry chemical down onto a protected area from a fixed location above the protected area. There are two different overhead nozzles; lowoverhead and high-overhead. The low-overhead nozzle, shown in Figure 2-9, uses a screen at the nozzle outlet to reduce the velocity of the dry-chemical dis- charge. This allows the nozzle to be positioned closer to the sur- face of a flammable liquid. WNPT I,, 3.16' "I Figure 2-9. Low-Overhead Nozzle, P/N 844258 The high-overhead nozzle, shown in Figure 2-10, is identical in design to the low-overhead nozzle, with the exception that it does not use a screen. This nozzle can be used at greater heights above the surface of the flammable liquid. Figure 2-10. High-Overhead (or Screening) Nozzle, PIN 259270 The tankside nozzle, shown in Figure 2-1,1,. is designed to dis- charge a flat, semicircular blanket of dry chemical over the sur- face of a flammable liquid. . Figure 2-11. Tankside Nozzle, P/N 259072 . -3.2 Total-Flooding Nozzle-*. PIN 83-100005-001 ......... . . . The total flooding nozzle shown in Figure 2-12 is designd to uniformly discharge dry chemical throughout an enclosed vol- ume. This nozzle is to be mounted at calling level, with the orifice tip pointed vertically down: The total flooding (IF) nozzle is also used to protect the work area volume for open face. spray booth applications. . . . . . . . Each total-flooding nozzle is factoryequipped with a blow-off cap to protect the nozzle orifices and prevent moisture buildup in the discharge piping. . WNPT NOZZLE PODY flT MALE REF. _ORFICE TIP NOZZLE BLOW-OFF CAP PIN 06-250099-067 Figure 2-12. Total-Flooding Nozzle, PIN 83-100005-001 UL EX-2153 2-7 . November 11998 fl Component Descriptions Industrial Dry Chemical S S 2-3.3 DuctlPlenum (DP) Nozzle, PIN 83-100006-001 The duct/plenum (DP) nozzle, shown in Figure 2-13, is designed to uniformly discharge dry chemical throughout an exhaust duct or plenum area specifically for open-face spray-booth applica- tions, or vehicle paint spray-booth applications. Each duct/plenum (DP) nozzle is factory-equipped with a blow- off cap to protect the nozzle orifices and prevent moisture buildup in the discharge piping. COVER BODY 4NPT (REF) Figure 2-13. Duct/Plenum (DP) Nozzle, P/N 83-100006-001 2-4 AUTOMATIC DETECTORS AND ACCESSORIES. 2-4.1 Fusible-Link Housing Kit, P/N 804548 The fusible-link housing kit consists of a fusible-link housing, two 1/2" EMT connectors, a supply of cable crimp sleeves and an S- hook to attach the fusible link to the 1/16" cable leading to the control head. Ur EMT irr LIlT CONNECTOR LOCIORIT LOCKNUT CONNECTOR Z/"...CABLETO 77_ IIIlTCABLE TO CABLE CONNECTOR ER. URIC' ANOTHER DETECTOR ACTUATINGOLIIICE CRAP TYPE i CRIAPTYPE OR REMOTE WMJAC. CABLE CONNECTOR CONTROl. Figure 2-14. Fusible Link Housing Kit, P/N 804548, with Fusible Link 2-4.2 Fusible Links (Model ML), P/Ns 282661, 282662, 282664, and 282666 UL-Listed and FM-Approved fusible links are used in conjunction with the fusible-link housing kit. The fusible links are held to- gether with a low melting alloy, which melts at a predetermined temperature, allowing the two halves of the link to separate. Figure 2-15. Fusible Link Fusible links are available in various temperature ratings as shown below. Table 2-3. Fusible Link Temperature Ratings Fusible Link Maximum Exposure Part . MlnlMax Rating Temperature Number Load Rating 165 deg F 74 deg C 100 deg F 38 deg C 282661 .10 lb/40 lb 212 dog F loo dog C 150 dog F . 65 deg C 282662 10 lb/40 lb 360 dog F . 300 dog F 282664 10 lb/40 lb 182 dog C 149 dog C 500 dog F 440 dog F 282666 10 lb/40 lb 26o dog C 226 dog C There are two temperature designations which apply to both fus- ible links and qua,tzoid bulb links (see above). One temperature is called the rating temperature, and the other is called the maxi- mum exposure temperature. The rating temperature, which is stamped on the fusible link, is the temperature at which the link will separate when new. How- ever, continual exposure to cycling ambient temperatures may cause a degradation of the link overtime. Therefore, the fusible links must be replaced at least annually with ,a new link having the prqperternperature rating. The maximum exposure temperature is the maximum ambient air temperature in which a fusible link may be installed. The maxi- mum air temperature at the point of link installation must not ex- ceed the maximum exposure temperature shown in the table. 2-4.3 Quartzoid-Bulb Link, PIN 260527 The quartzoid-bulb link is used in conjunction with the fusible link housing kit. The quartzoid-bulb link consists of a glass bulb, filled with liquid and a small air bubble, and a metal housing. Tempera- ture rise expands the liquid in the bulb and compresses the air bubble. When a predetermined temperature is reached, the ex- panding liquid breaks the glass bulb and allows the housing pieces to separate. Quartzoid-bulb links are available with a 500 de- grees F (260 degrees C) temperature rating. The maximum ex- posure temperature for the quartzoid-bulb link is 475 degrees F (246 degrees Q. Quartzoid bulbs to be used on industrial systems are UL listed and designated Issue B. The loop marked "A" should be installed toward the control head. Ouartzoid bulb links have an unlimited life expectancy before operation, and need not be changed on an annual basis. However, the local authority having jurisdiction may rule otherwise. On periodic inspection, the quartzoid bulb link must be wiped clean of grease and dirt with a clean dry cloth. UL EX-2153 2-8 November 1998 Industrial Dry Chemical CoinpoàeñtDescrlptiâns..• B A Thermo-Bulb links are available in various temperature ratings as shown in Table 24 Table 24. Thermo-Bulb Fusible Link Temperature Ratings Figure 216. Quartzoid Bulb 24.4 Fusible-Link Housing Kit The fusible-link housing kit consistr of a fusible-link housing. two 10 EMT connectors a supply of cable crimp sleeves and an S-hook to attach the Kidde KGR or KGS links to the, 1116 cable leading to the control head. II U4II 14 inrcLTQ I jarj nrcmu.i '\ qpiwu CAMCONNOCM LI L 1WE WtUWIljU EI C PIN , TYPE .. TEMP. COLOR 87-120090-165 STANDARD 16F RED . 87-120095-165 OUCK RESPONSE 165F RED 87-120090-212 STANDARD - 212F GREEN 87-120095-212 QUCK RESPONSE 212F GREEN• 87-120090-286. STANDARD 28SF BLUE. 87-120095-286 OUCK RESPONSE 286F BLUE, 87-120090-360 STANDARD 360F MAUVE 87-120095-360 QUICK RESPONSE 360F MAINE 87-120090-450 STANDARD' 450F BLACK 87-120095450 QPJCK RESPONSE' 450F BLACK 87-120090-500 STANDARD- 500F BLACK 87-120095-500 OUCK RESPONSE 500! BLACK' o Figure 2-17. Fusible Link Housing Kit with KGR Link 2-4.5 Thermo-Bulb Fusible Links UL-Listed and FM-Approved KGR or KGS links are used in con- junction with fusible-link housing kits. Thermo-Bulb Links are used in conjunction with the Kidde 804548 or 87-120061-001 fusible Link housing kits. The Kidde links are held together with a glass tube, which fails at a predetermined temperature, allowing the two halves of the link to separate. 1=)MMOMEW Figure 2-18. Fusible Link, Thermo-Bulb 2-5 THERMOSTATS 2.1 Thermostats .. . •. Thermostats are electric heat detectors. Therniostats-are. equipped with resettable, normally-open. contacts which close when a predetermined temperature is reached. .Thermoitats are.. constructed to compensate fOr rate 'Of temperature rise. If the' temperature rise is great enough, the detector contacts will dose at a temperature somewhat below the set point; LOW EXPANSION CONTACT . BRAZE-SEALED. STRUTS POINTS ' H SEALED— ELECTRICAL EAD END A0S SCREWS - EXPANDING 4ELECTRICAL GLASS BEADS.' OUTER SHELL INSULATION.. • HERMETIC SEAl. Figure 2-19. !h&nostat . Thermostats are available with' sot points as shown in 'Table 2-5. UL EX-2153 2-9 ' . '' November 1998 Part Maxbinim Number Point Exposure Temperature 12-E271210000- 140 dog 0 80 deg F 02 60 dog C 27 deg C 12-E27121.0000- 190 dog F loo dog F 04 88 deg C 38 dog C 12-E27121-0000--.225 dog F 125 deg F 05 107 deg C 52 dog C 12.F27121.0000- 325 dog 225 dog IF 07 183 deg C 107 deg C 12.G27121.0000- 450 dog IF 350 dog 07 232 dog C lll dog C 2-F271210000- 800 deg F 500 deg F 08 _16 dog C 260 deg C Component Descriptions Industrial Dry Chemical Table 2.5. Thermostat Set Points, 2-5.3 Mercury Check, Dill O71 AC III UI UUU The mercury check is used for pneumatic systems having more than four heat-actuated detectors (HAD's). The mercury check allows up to 4 HAD's to be grouped onto a ____________ ____________ ____________ • separate tubing branch line, and isolates each branch line from ,the others in order to maintain system sensitivity and. response time. The mercury check can accept a detection signal frqm up to 3 tubing branch lines. ,. . 3 KNOCKOUTS FOR CONDUIT I+__175 8r —+1' 2 NIPPLES FOR ATTACHMENT ENTRY ON THIS SURFACE "a cc COVER l!8x3l11 1UBING UNION . 4MOUNTING HOLES, 31W END READY FOR CONNECTION 3.1l6' TUBING UNIONS . LOCATION OF VENT • (238mm) ENCLOSURE I 2 MOUNTING SCREWS CHECK BOCY • 0 FOR CHECK BODY 2-5.2 Pneumatic Heat Detector (HAD), : , COVER OFF . . 'PIN 840.845 . . Figure 2-21. Mercury Check, PIN 871346 . ':. The pneumatic head detector, P/N 840845, consists of a hollow . brass chamber having no moving parts, and is connected to the 25.4 Heat Collector, pneumatic control head by copper tubing. The unit is installed in ' ' PIN 31272 . the heat collector, P/N 31272. Upon a rapid rate of temperature rise in the fire area, the pressure in the detector increases, and The heat collector, shown in Figure 2-22 is a 16-inch square the 'pressure increase is transmitted to the control head, tripping baffle plate used to capture rising heated air and combustion it to discharge the system. The pneumatic heat detector, tubing products generated by a fire. The heat collector is used when and pneumatic control head system are vented to prevent nor- the automatic heat detectors cannot be mounted at ceiling level, mal increases in temperature from tripping the system. , and is constructed of 18-gauge galvanized sheet steel. , , (Im 0.25' SLT-FOR ? 5nm) MOUNTING SCREW , 0nm) Ii _/' 4 MOUNTING SURFACE FOR PNEUMATIC /ZHEAT (M OUNT CENTER) EMT CONNECTOR ., \. (TYP) (406mm) \ . EMT(TYP) UPPER CAGE ., . j TUBING I ' 2.8r •_-' ' Figure 2-22. Heat Collector, P/N 31272 (73mm) . TUBING UNION (SUPPLIED WITH DETECTOR) CHAMBER / (135mm) LOWER CAGE Figure 2-20. Pneumatic Detector, P/N 840845 UL. EX-2153 . 2-10 November 1998 S Industrial Dry Chemical Compo,entDescrlptlóns. GUARD .. BRAOCET WITh 375(1I8in)DlA. 24 MANUAL RELEASE STATIONS -. MOUNT1WIIIOLE 241 Mechanical, Remote Manual Release, STEM PIN 875572, REIG The mechanical, remote manual release is provided as a means ' of manually actuating the system from a remote location. The mechanical, remote manual release isattached to the primary Pam , . control head with 1/16" cable. To actuate the system at the me- qhanical, remote manual release, pull out the ring pin and pull SPRING hard on the handle. , , I , Each manual release is supplied with a separate nameplate. This (Shun) nameplate must be attached to the mounting surface 1" above or . below the pull station. ' 1.37W (351un11) •, BODY HEX o. Figure 2-23. Manual Pull Station, P/N 875572 2-6.2 Pressure Operated Release, PIN .874290 Pressure releases are used to close off the hazard space upon system discharge. The release, operated by system pressure, is designed to release self-closing units for doors, windows and dampers. The maximum load to be attached to a pressure re lease is 100 lbs. (This is based on a minimum pressure of 75 psig at the pressure release) The pressure-operated release must be installed no more than 10 feet from the dry chemical cylinder. —FNPT PRESSURE INLET Figure 2-24. Pressure Operated Release, PIN 874290 2-7 MAINIRESERVE SYSTEM COMPONENTS 2-7.1 Two-Way Check Tee, PIN 896516 The two-way check tee, shown in Figure 2-25, is used for main....... and reserve cylinders that share a common piping system. The. check tee prevents loss of dry chemical upon discharge when one of the cylinders is removed for refilling, maintenance, or re- pair. . . . . (hlnvr.) 1PT RTS) Figure 2-25. Two-Way Check Tee, P/N 896516 2-7.2 Main-to-Reserve Transfer Switch, P/N 802398 . The main-to-reserve transfer switch installed on 'electrically activated systems having main and reserve cylinders. The switch is normally placed in the main" position, but, in the event of a main extinguishing system discharge, the switch is placed in the 'reserve' position to provide uninterrupted fire protection. while the main system is being recharged. CAUTION NEVER PLACE THE MAIN-TO-RESERVE TRANS- FER SWITCH IN THE "RESERVE" POSITION FOL- LOWING A MAIN-EXTINGUISHING-SYSTEM UL EX-2153 2-11 . November 1998 Component Descriptions. ' . . . .. Industrial Dry Chemical ACTUATION UNLESS THEACTUAT1NG DETECTOR OR, . - 6J3 MANUALSTA11ON HAS RESETOR BEEN RESETAND -r— (162mm) '. THE SYSTEM CONTROL UNIT (IF USED) HAS BEEN CLEARED OFALLALARMCONDITIONS. . .• :— I pwEla(AllcsaEclvRv&vE f 2'COGRSWS . .TO I / NMPIATE WGH LOGO . . 7 IS NAMEPLATE TOGGLE SIMMOOLMILE Ll SWITCH POLEDOLSLE THM I'COVER ENCLOSURE ,, j 42r GUAM EN COVER TOGGLE TERMUMS NT . ______ . , NOTE: COMNE. . ____ ENCLOSURE IS 4.12'(105mm)DEEP. ' — -I ' on I Lir . • MATERLAU CONO ---- uLEfBOX. slEawml _____________ RED E)4*EL TOGGLE SWTCHLEV BAImUTE . -. :: MRINGDLGRAM Figure 2-26. Main-to-Reserve Transfer Switch, P/N 802398 2-7.3 Pneumatic Main-to-Reserve Transfer Valve, PIN 871364 The main-to-reserve transfer valve is installed on pneumatically actuated systems having main and reserve cylinders. The switch . is normally placed in the "main" position, but in the event of a . ' main extinguishing system discharge, the switch is placed in the 'reserve" position to provide uninterrupted fire protection while the main system is being recharged. . ' CAUTION NEVER PLACE THE MAIN-TO-RESERVE TRANS- . FER VALVE TO THE "RESERVE" POSITION FOL- LOWING •A MAIN-EXTINGUISHING-SYSTEM ' ACTUATION. UNLESS THE . ACTIVATING DETECTOR(S) HAS/HAVE COOLED DOWN. 2- .f EMJ. CONNECTIONS COMPRESSION TYPE (70mm) APPROX. Figure 2-28, Corner Pulley, P/N 844648 S UL EX-2153 2-12 November 1998 TOGG. E LEVER - MAI 1 10 N RESER1E ,•r•9j.I0I, •u — 0 /0 0 6MOUN11NG HOLES COVER OPEN Figure 2-27. Main-to-Reserve Transfer Valve, ,P/N'871364 2.8 AUXILIARY COMPONENTS 2-8.1 Corner Pulley, " PIN 844648 The c9mer pulley is used to change the direction of the system cable runs The cable's protective conduit (1/2" EMT) is attached 'to the corner pulleys with the coupling nuts provided. The corner pulley is equipped with a ball-bearing pulley for minimum resis- tance to the cable travel. COVER SCREW 0.62' , I I (16mm) I:.'. Industrial Dry Chemical Component Descriptions.: 2-8.2 Tee Pulley, •. PIN 843791 : (. The tee pulley is required when more than one mechanical, re- mote manual release is used in the same system. . - .- f To Control Head Cable Clamp to. be • : Installed as Close to Single Outlet Single Outlet End as Possible _____ End 0 0 I Cable Clamp o. o To Remote Pull. To Remote Pull •• 000 _/ (Cover Removed) Figure 2-29. Tee Pulley, PIN 843791 2-8.3 1116" Cable, PIN 219649 : The control cable used in the system is stainless-steel, 1/16" O.D. stranded cable. The cable is run.from the various system devices, through 1/2" EMT conduit, to the system control head(s). Corner pulleys are always used to change the direction of the •• , cable. Tee pulleys are used for a two-way branch point in a cable • run. P/N 219649 is a 500-foot length of cable. 2-8.4 Crimping Tool, , •. •. : •. PIN 253538 The crimping tool is used in conjunction with cable-crimp sleeves, PIN 214951. Wherever the system 1/16" control cable must be looped or terminated, these cable-crimp sleeves and crimping : tool must be used. NOTE: SPLICING OF CONTROL CABLE IS NOT PERMITTED. NOTE: OTHER CRIMPING TOOLS ARE NOT . AUTHORIZED. • Figure 2-30. Crimping Tool, P/N 253538 2-8.5 System Recharge For recharge purposes, both regular BC dry-chemical powder • (sodium bicarbonate base) and multi-purpose ABC dry-chemical • powder (monoammonium phosphate base) are available in 50- pound pails. Use PIN 804904for regular BC dry chemical, and P/N 806411 for multi-purpose ABC dry chemical. • UL EX-2153 • 2-13 • • • November 1998 Industrial Dry Chemical . . . . Design . Chapter 3 •. . Design . ..Contents . . Paragraph. Title . . Page • . 1. Introduction To Design .................................................... .......................................................................................................3-5. 3-1 . Introduction ...........................................................................................................................................................3-5 . 3-1.1 . Purpose and Design ..........................................................................•..................................................................... DesigflLimitations ..................................................................................................................................................... 3-2• Application Types .............................................................. . .................................................................................... 3-5 3-2.1 Total-Flooding Systems ......................................................... . ................................................................... ........... 3-5 3-2.2 Spray-Booth Systems ...........................................................................................................................................3.5 3-2.2.1 Vehicular Spray-Booth Systems ............................................................................................................................... 3-5 - . 3-2.2.2 Open-Face/Industrial Spray Booth Systems ...... . ................ . ...................................... . .................................... . ...... 3-6 3-2.4 Local-Application Systems (For Indoor Use Only) ................................................................................................3-6 34.5 . Hybrid Systems ...................................................... .. ....... . ........... .................................. ......................................... 3-6 • 3-3 Analysis and Design as a Process ................................................................ 3-4 The Analysis and Design Process..................................................................................................................... . . 3-41 Hazard Analysis .................................................................................................................................................... 3-6 3-4.2 Suppression-System Selection .............................................................................................................................3-6 3-4.3 Nozzle Selection and Location ...................... . ............................. . ............................................................................ 3-6 3.4.4 • . .Tankage Determination.......................................................................................................................................... . , . 3.4.5 Detector Selection ............................................. ................ . .............. . ........................ .............................................3-7 . . . . •3-4.6 . Actuator Selection ........... ................................., ............................................................................ ....................3-7 3-4.7 Piping Layout ....................................................................... ............. ....................................................... . ............... 3-7 . . 3.4.8 Auxiliary Requirements ............................................ ........................................................ ..................................... 3-7 3-5 Applying the Method ............................................................................................................................................. 3-7 II. 'Detection Systems .................................................................................................................................................................34 . 3-6 • Introduction ...........................................................................................................................................................3-8 .• .' • .3-7 Fusible-Link Systems............................................................................................................................................3-8 3-7.1 . Fusible Link Selection...........................................................................................................................................3-8 3-7.2 . Fusible Link Spacing................................................................................................3-8 • 3-7.3 Cabling Limitations................................................................................................................................................ .. 3-7.3.1 Remote.Pull-Station Design Limitations...........................,:.................................................................................... . 1.8 Thermostat Systems .......................... ........................................................................... . ........................................ 3-9 • : 3-8.1 . Thermostat Selection ................................. ............................... . ................................................................. . .......... 3-10 3-8.2: ''Thermostat Spacing ............................................................................................................................................ .3-10 • 3-8.3 Cabling Limitations ..... . ..................................... .......................... .................................. . ....... ................................ 3-10 3-9 Pneumatic Systems .............................................................................................................................................3-10 3-9.1 HAD Seléction ......... ....................................................... ............................................... ....................................... 3-10 3-9.2 • HAD Spacing .......................................................................................................................................................3-10 3-9.3 , Tubing Limitations ...... . ................... . ......................................... . .... . ...................................................................... ... 3-11 3-9.4 Cabling Limitations .................................................................................................................................................. 3-11 3-10 OtherDetection Systems ........ . ............................................................................................................................ 3-11 S UL EX-2153 . 3-1 • November 1998 Industrial Dry Chemical Deàlgn. Chapter 3. ó Design o I. introduction To Design 3-1 INTRODUCTION This chapter introduces the designer, installer, or user to the pro- cess whereby dry-chemical fire-suppression systems are de- signed. It outlines the process, introduces the limitations imposed on design by system hardware, as well as those mandated by performance considerations. It also gives a brief introduction to the basic types of Industrial dry-chemical fire-suppression appli-' cations. As the designer familiarizes himself with this material, he should remember that analysis and design is a careful, step-by-step process. All steps must be followed, none can be omitted, and all unique aspects of a given application must be taken into ac- count if the resulting fire-suppression system is to deliver the desired protection. 3-1.1 Purpose and Design Dry-chemical systems are primarily used to extinguish flammable liquid fires. They are used in situations where fast extinguish- ment is required and where re-ignition sources are not present. Proper system design requires careful analysis to determine and define the nature of the hazard and the type of fire protection applicable to the hazard. The design sequence is described be- low. 3-1.2 Design Limitations In addition to performing the analysis and design process, and having a general knowledge of dry-chemical systems, the sys- tem designer must also have a working knowledge of all system and sub-system limitations; this knowledge is necessary to en- sure the effectiveness of the installed fire-suppression system. Each design must allow for the limitations of each part of the system: detector(s), actuator(s), nozzles, piping, tankage, and auxiliary control requirements. For example, some detectors are unsuitable for some types of fire hazard; the several nozzles available will distribute extinguish- ing agent in different patterns; some systems will require one kind of actuator rather than another, or may require a combina- tion of actuators; and finally, piping must be designed so that the agent is distributed effectively. The design limitations of industrial dry-chemical systems and their components are discussed in detail in this manual, and the designer should familiarize himself with them before beginning the design process. 3-2 APPLICATION TYPES There are relatively few generic types of dry-chemical fire suppression system applications. They vary from each other in terms of the nature, NFPA Class designation, and physical layout of the hazard, the flam- mable materials involved, whether or not the area to be protected is enclosed, whether there are assodateddects, plenums, andlor forced ventilation systems, whether them is awdliaiy equipment which must be controlled as part of any fire-suppression action, and in other ways. The main application types are: • 3-2.1 Total-Flooding Systems Total-flooding systems are used when there is :an enclosure around the protected equipment or material. Total-flooding sys- tems are designed to fill the enclosure with a concentration of dry-chemical sufficient to extinguish a fire in the combustibles involved. Discharge of the dry-chemical is through fixed, ceiling mounted nozzles connected to one or more cylinders. See Sec- tions I and II of Chapter 4 for complete design limitations. 3-2.2 Spray-Booth Systems Usually, a spray booth is an enclosure in which parts and equip- ment are spray painted or coated. When in operation, the booth is continually force-ventilated to remove flammable vapors, gen- erated during operations. A typical spray booth is usually divided into two sections by a bank of filters that extends from floor to ceiling. The two sections of the paint spray booth are the work area and the plenum. The work area is the larger of the two sections, and is the place where the parts and equipment are sprayed. The plenum is the space into which the exhaust gases flow after passage through the filter bank. The most common types of paint spray boOths are 1) vehicular (or automotive) spray booths and 2) industrial spray booths:. 3.2.2.1 VEHICULAR SPRAY-BOOTH SYSTEMS The vehicle spray booths are used for painting automobiles, vans, trucks, and other mobile equipment. There are two types of ve- hicular spray booths, 1) solid back and 2) drive through. The solid-back spray booth uses a basic spray-booth arrange- ment with a filter bank separating the booth into a work area and plenum, with forced ventilation exhausting the flammable vapors through the plenum and associated duct work. The work area will have a large door through which the vehicle is brought into the booth. This door is to remain dosed during spraying opera- tions. A drive-through spray booth will have doors at either end for vehicle entrance and exit from the booth. These doors are to remain closed during spraying operations. See Sectiàn Ill of Chapter 4for complete design limitations. - UL EX-2153 3-3 November 1998 Design . . ' . Industrial Dry Chemical 3-2.2.2 OPEN-FACE/INDUSTRIAL SPRAY BOOTH SYSTEMS. 3.4 THE ANALYSIS AND DESIGN PROCESS Most industrial spray booths have an open front face. The spray painting operation may bémanually-controlled or fully-automated. A fully-automated booth uses a conveyor belt to move parts into and out of the spray booth and has uncloseable openings on both sides to allow for parts conveyance. See Sections IV and V of Chapter 4 for complete design limitations. 3-2.4 Local-Application Systems (For Indoor Use Only) Local application systems are used when there is no enclosure around the equipment or process being protected. In a local- application system, the dry chemical is discharged directly on an unendosed hazard through fixed nozzles connected to one or more cylinders. Local-application protection is designed to cover a fixed piece of equipment such as a dip tank or a process in an open area that is wind-protected or sheltered. The dry-chemical can be locally applied either overhead with nozzles located over the hazard area, or in a tankside manner with nozzles located along the sides of a flammable or combustible liquid tank. Care must be taken to include splash areas during hazard analysis of local-application systems. See Section VI of Chapter 4 for com- plete design limitations. .3-2.5 Hybrid Systems Some applications combine features of total-flooding and local application. For example, an oil-quenching system with an asso- ciated conveyor belt might require both forms of coverage in or- der to control combustion at the surface of the quenching bath (local application), and along the length of the conveyor system (total-flooding). In the case of spray booths which vary widely in design, attention must be paid both to the requirements of the booth itself, as well as to associated ductwork or plenums. Some- times-the requirements of the booth may differ from the needs of the associated duct/plenum(s), and the analysis-design process must take this into account. Note that each segment of the hybrid system uses separate sys- tem cylinders and distribution piping. 3-3 ANALYSIS AND DESIGN AS A PROCESS Analysis and design should be approached as a methodical pro- cess, and performed step by step. Only when all the steps are followed is the resulting system likely to perform as desired. If any step is omitted, it is probable that the system will not function as well as it should. The steps in the analysis and design pro- cess are: Hazard analysis Suppression-system selection Nozzle selection, number and location Tankage, number, size, and location Detector selection Actuator selection Piping layout 0 • Auxiliary requirements Analysis and design proceeds through the following steps: 3-41 Hazard Analysis Determining the NFPA Class and severity of the hazard. Analysis also includes determining the physical layout of the hazard, the manner and speed with which the fire might propagate, and the likelihood of its spreading into adjacent areas. The classification of flammable liquids can be fotnd in NFPA 30: 'Flammable and Combustible Liquid Code? Flammable liquid characteristics can be obtained from sources of reference such as safety data sheets and NFPA 325M: "Fire Hazard Properties of Flammable Liquids, Gases, and Volatile Solids? The severity of the fire hazard gen- erally relates to the possibility of explosive conditions by created by flammable materials within the confines of the protected area. This danger can usually be mitigated by safeguards such as ad- equate ventilation; explosion-proof wiring and fixtures, and prod- uct containerization. . CAUTION IT IS IMPORTANT TO REMEMBER THAT, WITH DRY CHEMICALS, THERE IS NO INERTING OF THE PROTECTED SPACE FOLLOWING FIRE EX- TINGUISHMENT. IN APPLICATIONS WHERE IN- ERTING FOLLOWING FIRE EXTINGUISHMENT IS NECESSARY AND/OR DESIRABLE, CONSIDER- ATION SHOULD BE GIVEN TO GASEOUS EXTIN- GUISHING AGENTS SUCH AS FM-200, FE-13, OR CARBON DIOXIDE. 3-4.2 Suppression-System Selection Determining whether total-flooding, local application, or a combi- nation 'of the two approaches is best. Total-flooding systems are used if there is an enclosure around the hazard. Local-applica- tion techniques are used in situations where the hazard is unen- closed, but isolated from other hazards and can be protected by a dry-chemical discharge directed at it. 3-4.3 Nozzle Selection and Location Selecting the number and type(s) of nozzle(s) needed and locat- ing them so that the entire hazard is covered. Use the coverage/ distribution specifications for each nozzle type (ceiling mounted nozzles for total flooding applications, high or low overhead, or tankside nozzles, for local application, or duct/plenum nozzles for use in the exhaust ducts of spray booths) to determine the number of discharge nozzles required to deliver the necessary quantity of dry chemical given nozzle placement appropriate to the hazard. 3-4.4 Tankage Determination This step involves finding the quantityof dry-chemical agent re- quired, determining whether additional agent may be needed, and selecting the tankage which will supply the needed amounts dry chemical. After determining the amount of dry chemical needed to control the hazard itself, determine whether any special con- ditions necessitate additional dry-chemical quantities. For ex- ample, it may be necessary to increase the dry-chemical discharge rate in order to offset the effects of ventilation, or it may be nec- essary to screen openings in an enclosure to prevent dry-chemi- UL EX-2153 3-4 November 1998 : Industrial Dry Chemical - Design.'- cal leakage through those openings Also depending upon the 3-48 Auxiliary Requirements .criticality of the application and/or the potential for re-ignition it may be necessary to provide a connected reserve supply of dry For example adding controls to turn off forced-draft ventilation chemical . systems, fuel (or combustible-liquid) pumps, conveyers, etc.. .. - Such controls (usually automatic, and triggered by the system's 3-4.5 Detector Selection detection apparatus) are often necessary to-limit the severity or. spread of a fire. Detector selection will depend on the response speed required, the probable heat level and rate of spread of the fire. The detec- tors used for indutrial dry-chemical fire-suppression systems de- tect the heat energy released by the combustion of a fuel and dxygen. Upon detection of a fire, the detection system sends a signal tothe system control head(s) which initiates the dry-chemi- cal discharge. The most commonly used detectors are the: Fixed-temperature fusible link Rate-compensated thermostat Pneumatic, rate-of-rise, heat-actuated detector (HAD) The following section details selection of the appropriate.detec- tor and also disáusses actuator systems. 3-4.6 Actuator Selection Depending on the hazard analysis, and the speed of response required, actuation may be manual, automatic (driven by the detector(s) used), or a combination of the two. See the section which follows for additional information. 3-4.7 Piping Layout Careful piping. layout assures that that the agent reaches the distribution nozzles evenly and appropriately, and that piping limi- tations are addressed. These limitations involve pipe lengths, the number of elbows, and other factors such as the symmetry of piping between tankage and nozzles, and the allowable distances from agent storage tanks. These limitations are discussed in de- tail in the design examples contained in the sections on applica- tion types. 3-5 APPLYING THE METHOD i... . . . . ... ,. - Using tie information gained in the previous steps, create the final design of the fire-extinguishing system: . . . Decide the type(s) and number of discharge nozzles to be used and determine their locations. . . . . . . Determine the number, size, and location(é) of the dry-chemi- cal. cylinders. Lay out the piping system(s). Design the automatic and/or manual 8re4etection system(s): Select the type of automatic detector(s) to be usd and de- termine detector location(s). . - . ... Select the type of manual releale(s) for the system and de- termine mounting location(s). Select the control system to interface between the fire-de. tection system and the fire extinguishing system. Determine the auxiliary equipment-required such.as pres- sure releases or alarm bells, fan or pump controllers. ;-- - This process is illustrated in the sections of this manual dealing with applications, analysis, .and design examples. UL EX-2153 3-5 November 1998 Design Industrial Dry Chemical 46- II.. Detection Systems ' 0 34 INTRODUCTION The detectors used for industrial dry-chemical fire-suppression systems are designed to detect the heat energy released by the combustion of a fuel and oxygen. Upon detection of a fire, the detection system sends a signal to the system control head(s) which initiates the dry-chemical discharge. Three commonly used detectors are the fixed-temperature fusible link, the rate-com- pensated thermostat, and the pneumatic, rate-of-rise, heat-ac- tuated detector (HAD). 3-7 FUSIBLE-LINK SYSTEMS Fusible link detectors are used for mechanical systems and are attached with a 1/16-inch steel cable to a mechanical control head. The fusible link is made of an alloy designed to melt at a certain temperature. When the fusible link melts, the tension in the cable connecting it to the control head is released, which actuates the spring-loaded plunger in the control head. This, in turn, actuates the cylinder valve, releasing the dry chemical into the distribution system. In addition to releasing the dry chemical to suppress the fire, the mechanical control head can be supplied with one or two op- tional microswitches for equipment-interlock purposes. The me- chanical control head is equipped with a local manual release lever and can also incorporate a remote manual release station. 3-7.1 Fusible Link Selection For automatic actuation to occur during a fire, the fusible links must be heated sufficiently to melt and cause actuation. Experi- ence has shown that it may take several minutes for fusible links to actuate, and actuation is dependent upon: Fire intensity Fusible link temperature rating Fusible-link spacing and location In order to minimize delays in link response time, it is necessary to conduct a temperature survey at all locations where detector links will be installed. The survey must be conducted under maxi- mum operating conditions (i.e., at the highest operating tempera- tures and airflows) to determine the optimum exhaust airflow locations and record the peak temperatures that are expected to occur. Once the survey is completed: Select the lowest temperature-rated link that can be used. Make sure that the maximum exposure temperature of the link exceeds the maximum temperature obtained from the survey. Make sure that the links are located in the exhaust airflow, not in dead air spaces. This will provide the fastest response. WARNING TEMPERATURES RECORDED. SEETABLE 2-3 FORUNK MAXIMUM EXPOSURE TEMPERATURES. '3-7.2 Fusible Link Spacing The fusible-link housing kit, shown in Figure 3-1, provides the flexibility required to install fusible links in a wide variety of in- dustrial applications. Depending upon the size of the area being protected, the number of fusible links used can range from a minimum of I up to a maximum of 25. When multiple fusible links are used, they are connected to each other in series using 1/16-inch stainless steel cable to form a continuous chain. The 1/16-inch cable leads to the mechanical control head from the link nearest to the.control head. Kidde Rapid-Response Thermo-Bulb links (KGR) can.be spaced every 20 feet for smooth ceilings up to 12 feet high. Consult NFPA 72E for reductions in spacing far ceiling heights in excess of 12 feet, and for spacing guidelines when different ceiling ar- rangements are encountered. Pàtential fire hazards and/or fire development scenanàs may re- quire closer fusible link spacings. Consult the' authority having jurisdiction in these situations. EMT EMT ADAPTER ADAPTER BRACKET WENT CABLE TO MECHANICAL CONTROLNEAD OTHER 1-W DETECTORS Zo.KIFUSIBLELINK CRIMPSLEEVE LAST DETECTOR f IN SERIES EMTADAPTER BRACKET % ;- EMT 10 MECHANICAL CONTROL HEAD OR OTHER DETECTORS S7dNLESS t CRIMP SLEEVE STEELCABLE FUSIBLE LINK SHOOK Figure 3-1. Fusible-Link Detector Installation WARNING ALL FUSIBLE LINKS MUST BE CONNECTED IN SE- RIES IN ORDER FOR THE SYSTEM TO PROPERLY OPERATE. ONLY ONE (1) DEAD-ENDED LINK IS PERMITTED. 3-7.3 Cabling Limitations Figure 3-1 shows the first (or a typical intermediate) fusible-link detector in a multi-detector string, and.also shows the last detec- tor in the string. The detectors are attached to the mechanical control head with 1/16-inch steel cable. Note that the cable must be run in electrical metal tubing (EMT) for protection. Table 3-1 gives the maximum cable length, maximum number of corner pulleys and maximum number of fusible links for one con- trol-head installation. TO AVOID ACCIDENTAL SYSTEM DISCHARGE, LINKS S MUST HAVE AN EXPOSURE TEMPERATURE RATING - GREATER THAN THE MAXIMUM PEAK SURVEY UL EX-2153 3.6 November 1998 * Two Corner Pulleys = One Tee Pulley Cable runs to mechanically-operated components must be hon. zontal or vertical only. Corner pulleys or tee pulleys must be in- stalled for a 90-degree change in direction. Figure 3-2 shows an unacceptable cable configuration. WARNING ALL CHANGES IN DIRECTION OF CABLE RUNS MUST BE MADE USING KIDDE CORNER PULLEYS OR TEE PULLEYS. NO CONDUIT PIPE BENDS ARE PERMITTED. FAILURE TO FOLLOW THESE IN- STRUCTIONS WILL PREVENT THE SYSTEM FROM OPERATING. Figure 3-2. Unacceptable Cable Configuration 3-7.3.1 REMOTE-PULL-STATION DESIGN LIMITATIONS Mechanical, remote manual release stations supplement auto- matic detection. Figure 3-3 shows single and dual-mechanical, remote pull stations. Use a tee pulley for dual pull stations. Table 3-1 gives the maximum cable length and number of corner pul- leys permitted for this sort of installation. Note that the cable line to the remote pull station(s) is run in EMT for protection. Remote manual pull stations shall be located in a path of exit or egress and shall be clearly identified. o S., -- Industrial Dry Chemical Table 3-1. Installation Maximums for Cable Runs - - Primary Primary From: Primaly Head Head Head To: Fusable-Link Mechanical TandemControl Detector(s) Pull Station(s) Head 1/16-inch 100 100 100 Cable (Feet) Corner Pulleys, 30 30 • 30 P/N 844648. Tee Pulleys, 0 1 0 P/N 843791 Fusible 25' - - Links Mechanical - 2 - Pull Stations (PM esaw" ea com r PUS stow (PM 875m) Figure 3-3. Remote Pull Stations 3-8 THERMOSTAT SYSTEMS . . - Thermostats are used with electric control heads and are elec- trically wired directly to the óontrol head or:to, an intervening control unit. CAUTION ALL SYSTEMS WiTH ELECTRIC ACTUATION MUST BE PROVIDED WITH A CONTINUOUS, SUPERVISED BACKUP POWER SOURCE CAPABLE OF OPERAT- ING THE SYSTEM FOR AT LEAST- 24 HOURS, UN- LESS THIS REQUIREMENT IS EXPLICITLY WAIVED BY THE AUTHORITY HAVING JURISDICTION. The actuating cam in an electric control head is held in place by a solenoid. The thermostats contacts are normally in the open position. When a fire raises the temperature at the thermostat, the thermostat's contacts close, sending a signal directly to the control-head solenoid or to an intervening control unit (which sends a signal to the control-head solenoid). This releases the actuating cam, which causes the plunger to drop and actuates the cylinder valve. The dry chemical is then discharged through the distribution system. In addition to releasing the dry chemical to suppress the fire, the electric control head is equipped with microswitches for equip- ment-interlock purposes. Electric control heads are equipped with a local manual release lever, and can incorporate a remote - manual release. UL EX-2153 3-7 November 1998 I. Design ' 'Industrial Dry Chemical IN S CAUTION 34.1 Thermostat Selection The thermostat must be heated to its setpoint temperature for automatic actuation to occur during afire. Automatic actuation is dependent upon: Fire intensity Thermostat setpoint Thermostat spacing and location In order to minimize delays in thermostat response it is impera tive that a temperature survey be conducted at all locations where thermostats will be installed. The survey must be conducted un- der maximum operating conditions (i.e., at the highest operating temperatures and airflows) to determine the optimum exhaust airflow locations and record the peak temperatures that are ex- pected to occur. Once the survey is completed: Select the thermostat with the lowest usable setpoint. Make sure that there is approximately a 75 degree F to 100 degree F buffer between the thermostat setpoint and the maximum temperature obtained from the survey. Make sure that the thermostats are located in the exhaust airflow, not in dead-air spaces. This will provide the fastest detector response. 3-8.2 Thermostat Spacing The number of thermostats required for a particular industrial application is a function of the size of the area being protected. Since the thermostat is an unpowered electrical component, there is no upper limit established for the maximum number of detec- tors that can be used for a given system. In practice, issues such as voltage drops caused by wiring resistance impose certain limitations on the lengths of wiring that can be used. For applica- tions that require control units, consult the appropriate control- unit installation manual for wiring limitations. When multiple thermostats are used, they are electrically connected in parallel. Thermostats are spaced every 20 feet for smooth ceilings up to 12-feet high. Consult NFPA 72E for reductions in spacing for ceiling heights in excess of 12 feet, and for spacing guidelines when different ceiling arrangements are encountered. 3-8.3 Cabling Limitations Electrical systems using thermostats may use remote mechani- cal release stations and tandem control heads. Consult Table 3- 1 for installation limits of mechanical cable lines. 3.9 PNEUMATIC SYSTEMS Pneumatic, heat-actuated detectors (HADs) are used for pneu matic systems and are connected via 1/8-inch outside-diameter (OD) copper tubing either directly to a pneumatic control head or to an intervening mercury check. The heat-actuated detector consists of a hollow brass chamber having no moving parts and with appropriate connectors fOr at- tachment to 1/8-inch CD copper tubing. Upon a rapid rate of tem- perature rise due to a lire in the protected area, the pressure in the HAD increases,'and'this pressure increase is transmitted via the copper tubing directly to the pneumatic control heàd.or to an.inter- vening mercury check (which sends a signal to the pneumatiô con- trol head). This, releases the actuating cam, which causes the plunger to drop and actuates the cylinder valve. The, dry chemical is then discharged through the distribution system. The HAD's, tubing, and pneumatic control head are vented to prevent normal temperature increases from actuating the system. In addition to releasing the dry chemical to suppress the, fire', the pneu- matic control head can be supplied with one or tWo optional micioswitches for equipment.interlodc purposes. The pneumatic con.- troll head is equipped with a local manual release lever and can also incorperate a remote, mechanical, manual release station. 3-9.1 HAD Selection The HAD must be rapidly heated for automatic actuation to oc- cur during a fire. Automatic actuation is dependent upon: Fire intensity' . HAD spacing and location In order to minimize delays in HAD response, and to account for transiept temperature fluctuations in the protected area, it is im- perative that a temperature survey be conducted at all locations where HADs will be installed. The survey must be conducted under maximum operating conditions (i.e., at the highest operat- ing temperatures and airflows) to determine the optimum exhaust airflow locations and record the peak temperatures that ire ex- pected to occur. Once the survey is completed: Ensure that no HAD is mounted at a location where normal process conditions can cause temperature increases to oc- cur at rates faster than 20 degrees ,F per minute. Make sure that the HADs are located in the exhaust airflow, not in dead-air spaces. This will provide the fastest detector response. 3-9.2 HAD Spacing The pneumatic, heat-actuated detector (HAD), shown in Figure 34, is attached to a mounting bracket for ease of installation in industrial applications. Depending upon the size of the area be- ing protected, the number of HADs used can range from a mini- mum of 1 up to a maximum of 12. When up to 4 HADs are required, they are parallel branched by means of tee connec- tions from a common tubing line, and the tubing is connected directly to the control head. When more than 4 HADs are re- quired, they are evenly distributed on separate tubing lines and the individual tubing lines are connected to a mercury check, P/N 871346. The mercury check is then connected to the pneumatic control head. o IT IS LIKELY THAT INDUSTRIAL APPLICATIONS IN- VOLVING FLAMMABLE OR COMBUSTIBLE LIQUIDS WILL BE ENCLOSED WITHIN OR SURROUNDED BY AREAS THAT WILL BE,CLASSIFIED AS CLASS I OR CLASS II, DIVISION I OR DIVISION 2 LOCATIONS. DRY-CHEMICAL SYSTEM ELECTRICAL COMPO- NENTS, SUCH AS THERMOSTATS, LOCATED WITHIN THESE AREAS SHALL BE RATED FOR USE IN CLASSIFIED AREAS, AND ALL WIRING TO THESE COMPONENTS SHALL CONFORM TO THE PROVI- SIONS OF NFPA 70, NATIONAL ELECTRICAL CODE, FOR CLASS I OR CLASS II, DIVISION 1, OR DIVI- SION 2 LOCATIONS. ANY INDUSTRIAL SYSTEM CONTROL HEAD WITH A MICROSWITCH IS NOT SUITABLE FOR USE IN A CLASSIFIED AREA. - UL EX-2153 3-8 November 1998 Industrial Dry Chemical Design f WCOWECM NOTE: The final leg of the copper system connects 'to MoLlaw f EMTITYP) the pneumatic control head by means of 3/16-jnch, OD tubing. There is no way to encloSe this leg in electrical, ' _____ metal tubing (EMT) for protection; therefore, thicker' walled tubing is required. Refer to Figufé3-5. +—'-. FmmHD'. , • -,-- I flOGUlCN IfsIWTdft ' I LEOWHOETETI , WC4CKkVSBt ' I 53$ /iIs • Figure 3-4. Heat-Actuated Detector, P/N 840845 If Tocood —. HADs are spaced every 20 feet for smooth ceilings up to 12 feet 'high. Consult .NFPA 72E for reduction in spacing for ceiling heights .802538 in excess of 12 feet, and for spacing guidelines when different : Juncum '.' ceiling arrangements are encountered. I , • :. ' ' NOTE: HADs are spaced every 15'-10" for applications, Figure 3-5. Junction of 1/84nch and 3/16-inch tubing requiring Factory Mutual System Approval. 3-9.4 Cabling Limitatlonè 'Tubing Limitations ' Pneumatic systems may use remote mechanical release .sta- The response time of a pneumatic detection system is depen- tions and tandem control heads. Refer to Table 3-1 for installa- ru . dent upon a number of factors, such as: tion limits of mechanical cable lines.: a. Fire intensity , ' ' ' '. •: HAD spacing and location Control-head setting and vent size 3-10 OTHER DETECTION SYSTEMS " Volume of copper tubing ' Although it is most common to use heat detectors for industrial fire It is important to remember that the system will actuate when the protection systems, there may be some applications where. an- entire sensing volume (HADs, copper tubing, and pneumatic- other mode of detection, such as flame or radiation detection, is o control-head sensing chamber) is pressurized to a level equal to more appropriate. Any UL-listed and/or Factory-Mutual-System- the control-head setting (For example, 4 inches of water). To approved detector may be used to actuate the extinguishing sys-' • . ensure a fast response to rapidly progressing or intense fires, tem provided that the ,detector is appropriate to 'the typeof, the tubing System must be limited to a total length of 200 feet or combustibles involved and is connected to a listed and compatible less of 1/8-inch OD copper tubing for a single-line system, or a control unit. The control unit shall bé'UL-listed and/or Factory Mu- total length of 200 feet or less of 1/8-inch OD copper tubing for tual System approved for releasing device service and compatible • each line of a 'multi-branch system. with the dry chemical extinguishing system equipment.. • , There are two types of industrial fire-suppression systems; local application and total flooding. , • UL EX-2153 • 3-9 '" ' November 1998 H UL EX-2153 3-10 November 1998 71 System Design DIP NOZZLE A DUCTIPLENUM(DIP)NOZZLE NIGH-OVERHEAD (S) NOZZLE TOTAL-FLOOD (T9 NOZZLE 314 In •• - - - CYLINDER - - [Figure 3-11. Maximum Piping Parameters (for Dedicated Duct Protection of Open-Face Spray Booths), )ND-25, Single D/P Nozzle . . . . .. ..• . Table 38. Maximum Pinina Parameters IND-25, Sincile D/P Nozzle.,,-- - - Parameters . Cylinder to DP Nozzle •• • Required Pipe Size . 3/4 in. Maximum Linear Pipe 52 ft. 6 in. (16 m) . Maximum 900 Elbows . 0-7 Delta H 38 ft. 6 in. (12 m) Maximum Equivalent Length .66 ft. 6 in. (20 m) • . . . -. ~ 0 P/N 220423 . • 3-19 - . .. . June 2005 Industrial Dry Chemical Applications and Examples Chapter Applications and Examples contents Paragraph Title Page I. Total-Flooding Systems .............................................................................................................................................................4.3 4-1 Total-Flooding Systems ................................... . ..................... ..................... .... .... ......... .................................................4-3 4-2 Uncloseable Openings .................................................................................................................................................4..3 4-2.1 Multiple-Cylinder Applications ......................................................................................................................................4.4 4-3 Use of Total Flooding Systems .......................................................... . ......................................................................... -4 4-3.1 Coverage ........................................................................................................................................... . .......................... 44 4-3.2 Undoseable Openings ................................................................................................................................... ...........4-4 4-3.3 Equivalent Length ............................................... . .............. . .......................................................... ....................... ...... .. -4 4-3.4 Flow Division ................................................................................. . .............................................. ......... . .............. ... ...... 45 4-3.5 Material for Pipe and Fittings ......................................................................................................................................4-5 II. Total-Flooding System Design Examples ...........................................................................................................................4.7 4-4 Solvent Storage Room Example ........................................................................ . ...................................... . ......... ........... 4-7 4-4.1 Hazard Analysis ...........................................................................................................................................................4-7 4-4.2 Nozzles ........................................................................................................................................................................4-8 4-4.3 Cylinders .....................................................................................................................................................................4-8 4-4.4 Detection System .........................................................................................................................................................4-8 Ill. Vehicle Paint-Spray Booths ...................................................................................................................................................4.9 4-5 Vehicle Paint-Spray Booths .... .......................................................... . ..................................................... .....................4-9 • .4-5.1 Work Areas and Plenums ............................................................................................................................................49 4-5.1.1 Plenums and Ducts .....................................................................................................................................................4-9 4-5.1.2 Combinations of Work Areas and Plenums .................................................................................................................4-9 4-5.1:3 Under-Floor Plenums .................................................................................................................................................4-9 4-5.2 Vehicle Paint Spray Booth Protection ................... . ............................... . ........................................................................ -9 . 4-5.2.1 Work Area-Protection ..................................................................................................................................................4-9 • 4-5.2.2 Work Area Modularization ...........................................................................................................................................4-9 • 4-5.3 Plenum Protection .................................................... ......, .4-10 4-5.3.1 Raised-Floor (Basement) Plenum Protection ...... . ........... . ......... . ................................................................................. 4-10 4-5.3.2 Pit-Type Plenum Protection ........................................................................................................................................4-10 4-5.3.3 Cross Flow (solid and Drive-through (U"-shape) Draft Plenum Protection ...............................................................4-10 4-5.3.4 Exhaust Duct Protection .............................................................................................................................................4-10 4-5.4 Ventilation Shutdown ..................................................................................................................................................4-11 4-6 Care of Installation ............................................... .............................. ..... ... ... .... .......................................................... 4-11 . Open Face Spray Booths ......................................................................................................................................................4-19 4-7 Introduction .................................................................................................................................................................4-19 4-7.1 General Description .......................................... ........................................................................................................... 4-19 4-7.2 Spray Booth Protection .............................................................................................................................................4.19 4-7.3 Work Area ........................................................................ ............................................................................................ -19 4-7.4 Plenum .......................................................................................................................................................................419 4-7.5 Exhaust Ducts (BC Only) .................................................................................................... ......................................... 4-20 4-7.5.1 Ventilation-System Shutdown for BC Dry-Chemical Applications ........................ . ...................................................... 4-20 4-7.6 Detection System .......................................................................................................................................................4-20 4-7.7 Care of Installation ..... ................................................................. . ............................................................................... 4-20 4-7.8 Piping for Open-Face Spray Booths...........................................................................................................................4-22 Open-Face Booth Design Examples. ................................. . ................................................................................................. 4.25 4-8 Introduction .................................................................................................................. ...............................................4-25 4-9 .. Example One ............................................................................................................................................................4-25 4-9.1 Hazard Analysis ..........................................................................................................................................................4-25 4-9.2 Extinguishing System .................................................................................................................................................4-25 4-9.3 Detection System .......................................................................................................................................................4-26 4-10 Example Two ..............................................................................................................................................................4-27 4-10.1 4-10.2 . 4-10.3 Hazard Analysis ..... ........................................................................................................................... ....... ......... ..... .. ... Extinguishing System .................................................................................................................................................4-27 .................................... 4-27 Detection System ...................................................................................................................4-28 UL EX-2153 4-1 November 1998 Applications and Examples Industrial Dry Chemical Contents (Cont.) Title Page • Paragraph VI. Local-Application Systems ..................................................................................................................................................4-30 : 4-11 Local-Application Systems .............................................................. .. ............................. ................................ .........:.. 4-30 4-12 Designing Local-Application Systems .................... ............................................................................... ......................... 430 4-12.1 Overhead Nozzle Coverage, PIN 844258 and 259270 ............................................................• .........4-30 . 4-12.1.1 Overhead-System' Piping Limitations ......................................... ........... ................................. ......... ..........................4-30 . 4-12.2 Tankside Nozzle Coverage .......................................................................................................................................4-32 4-12.2.1 Tankside-System Piping Limitations .............................................................................. ................... . ....................... :4-32 4-13 Oil-Quenching Operation .........................................................................................................................................434 4-13.1, Hazard Analysis ...................................................................................................................................... ..................4-34 . .. 4-13.2 Nozzles................................................................................................................................................................ 4-13.3 . Cylinders* ...................................... . .......................................................................................... . .......................... .... ..... 4-35 4-13.4 Detection System.....................................................................................................................................4-35 .. UL EX-2153 4.2 . November 1998 Industrial Dry Chemical Applications and Examples Chapter 4 Applications and Examples I. Total-Flooding Systems 4.1 TOTAL-FLOODING SYSTEMS Total-flooding systems are used when there is an enclosure around the protected equipment or material. Total-flooding sys tems are designed to fill the enclosure with a concentration of dry-chemical sufficient to extinguish a fire in the combustibles involved. Discharge of the dry-chemical is through fixed, mounted nozzles connected to one or more cylinders. Regular, BC (sodium-bicarbonate base) dry-chemical is used.to protect flammable or combustible liquid total-flooding hazards. Multi-purpose, ABC (monoammonium-phosphate base) dry chemical is used for total-flooding applications involving ordiflary combustibles (Class A) and flammable or combustible liquids. NOTE: For a total-flooding system to be effective, it is important that all ventilation be shut off no later than the start of dry-chemical discharge, and wherit possible, that all openings be closed. When ventilation is NOT shut down, supplementary dry chemical must be added at the point of air entry. Refer to NFPA 17, Section 4- 2.2.6.1 and the example calculation below. EXAMPLE: Additional Hazard Volume to be Protected 6 ft. x 10 ft. air-input opening 100 ft./min. velocity (V) measured at opening 10 lb./10 sec. or I lb/sec discharge rate 1350 cu. ft. maximum coverage per nozzle Calculate the following: Area (A) = (6 ft)(10 ft.) = 60 sq. ft. Air Flow (Q) = VA = (100 ftimin.)(1 min./60 sec.)(60 sq.ft.) = 100 cu. ft/sec. Volume of air removal during 10 second discharge:. =.(100 cu. ftlsec.)(losec.) = 1000 cu. ft. Additional nozzle coverage: = (1000 cu. ft.)I(1350 Cu. ft.) . = 0.74 nozzle(s) Rounding up 0.74 to next whole number = one additional nozzle at point of air entry. 4-2 UNCLOSEABLE OPENINGS The concept of an uncloseable opening applies only to total flooding syslems. An uncloseable opening is a permanent open- ing in the enclosure envelope that cannot be closed or shut prior to or at the start of dry-chemical discharge. Hazards with an uncloseable opening area equal to 5% or less of the total enclosure surface area do not require any additional dry chemical. The Kidde ft-chemical extinguishing system units have not been evaluated by Underwriters laboratories Inc. with respect to the total flood protection of hazards incorporating unclosable openings exceeding 5% of the total hazard surface area. Table 4-1. Total Flooding Nozzle Coverage Maximum Coverage Per Nozzle Total Coverage Two Nozzle. IND.21125 Four Nozzle. iND.45150 Hazard Height (Feet) Longest Side (Feet) Area (Square Feet) Volume (Cubic Feel) Area (Square Feet) Volume (Cubic Feet) Area (Square Feet) Volume (Cubic Feet) 12 or less 15 112.5 1350 225 2700 450 5400 13 15 104.0 1350 208 2700 416 • 5400 14 15 96.5 1350 193 - 2700 386 5400 15 15 90.0 1350 180 2700 360 5400 16 15 84.5 1350 169 2700 338 5400 17 15 79.5 1350 159 2700 318 5400 18 15 75.0 1350 150 2700 300 5400 19 15 71.0 1350 142 2700 284 5400 20 15 67.5 1350 135 2700 270 5400 UL EX-2153 • 4-3 November 1998 Applications and Examples Industrial Dry Chemical 4-2.1 Multiple-Cylinder Applications Multiple-cylnder systems are used to protect large applications that exceed the coverage obtainable with a single cylinder. In these cases, two or more cylinders are applied to a single hazard installation. Multiple-cylinder systems can be used for large hazards provid- ing that: • I There is a common fire-detection system. Each cylinder is protecting an area or volume that does not exceed the listed coverage for a single cylinder. Each cylinder has its own distribution piping and all piping conforms to established limitations for pipe sizes and pipe lengths. All cylinders are actuated simultaneously. NOTE: For total-flooding systems, different size cylinders (e.g., IND-25 and IND-50) can be combined to protect the same hazard. 4-3 USE OF TOTAL FLOODING SYSTEMS Total flooding systems are used when there is an enclosure around the protected equipment or material. All ventilation must be shut-down at the time of agent discharge and, if possible, all openings must be closed. 4-3.1 Coverage The protected space is divided into volume segments for cover- age purposes. For applications with ceiling heights up to and including 12 feet, the maximum surface area coverage for each nozzle is 112.5 square feet, subject to a longest side, for rectan- gular areas, not to exceed 15 feet. The maximum distance from the ceiling to the nozzle tip is 4.5 inches. One IND-21 or IND-25 must use two total-flooding discharge nozzles (P/N 83-100005-001. See Chapter 2 for description), pro- viding a total area and volume coverage of 225 square feet and 2,700 cubic feet, respectively. One IND-45 or lND-50 must use four total flooding discharge nozzles, providing a total area and volume coverage of 450 square feet and 5,400 cubic feet, re- spectively. The maximum area and volume coverages are in Table 4-1. Each nozzle should be centered in its protected volume segment. For ceiling heights up to 20 feet, the volume coverage per nozzle is retained, but the area coverage is reduced as listed in Table 4- 1. Figures 4-1, 4-2, and 4-3 show maximum area coverages for total flooding applications. 4-3.2 Uncloseable Openings Hazards with an uncloseable-opening area equal to 5% or less of the total enclosure surface area do not require any additional dry chemical. The Kidde dry chemical extinguishing system units have not been evaluated by Underwriters Laboratories Inc. with respect to the total flood protection of hazards incorporating unclosable S openings exceeding 5% of the total hazard surface area. 4-3.3 Equivalent Length When a fluid flowing in a pipeline changes direction, such as at an elbow or at a tee, the ensuing disruption of the flow always results in a loss of fluid pressure. For the purposes of pressure drop calculations, it is convenient to replace a fitting with a sec- tion of straight pipeline. The length of the substituted piece of pipe is chosen so that the pressure drop across it equals the pressure loss through the fitting it replaced. In this sense, each type of fitting is equivalent to a certain lendth of straight pipeline, and each fitting is assigned an 'equivalent length.' Substitutions of this type allow each point in the distribution system to be de scribed by two numbers - one number being the actual linear length of pipe to that point, and the second number being the total equivalent length of pipe to that point, taking fittings into account. Fittings, for equivalent-length purposes, are defined as side- flow (bull) tees and 90-degree elbows. Straight connectors and uniàns may be used anywhere in the distribution system, since there is no change in direction at these fittings to contribute to the equivalent length. Refer to Table 4-2 lbr equivalent-length data. The main supply line, the sub-supply lines (four.-nozzle cylin- ders), and the nozzle branch lines are each rated for a maxi- mum pipe length and a maximum equivalent pipe length. There is no minimum pipe length or fitting requirement. Any number of 90-degree elbows can be used on the.supply line, subject to the equivalent length limitations. Additional 90-degree elbows can be used on the sub-supply lines and the nozzle branch lines, subject to equivalent length and balancing constraints. The change in direction at the cylinder's valve outlet is not counted as a 90-degree elbow. Table 4-2. Equivalent Length of Pipe Fittings Fitting Type Pip. 51a 314 Inch 1 Inch 90 degree Elbow 2.0 2.0 Tee 4.0 5.0 ceo cHEOUCAL CYLINDER I50FT -T DRY CHEMICAL_, - CYLINDER FOOT .- 300 FT Figure 4-1. Total Flooding Coverage, IND-25/IND-21 UL EX-2153 4A November 1998 Industrial DiyChemiçal ' . . . . . . Applications and Examples Oft WNW& R • .• y __-* 4 1I, s_ __, I ' gn ,f20 PIPE DIAMETERS a.MINIMUM REQUIRED '20 PIPE DIAMETERS MINIMUM LENGTHS ,- MINIMUM LENGTH 0 PIPE DIAMETERS. . • REQUIRED. PIPE SIZE MIN4GTWOD 15, Figure 44. Distribution Systems Requiring Minimum Pipe Lengths . 0 Figure 4-2. Total Flooding Coverage, IND-50/IND-45 Figure 4-3. Total Flooding Coverage, lND-50/1ND-45 44.4 Flow Division When the flow of a two-phase fluid changes in direction, such as at an elbow, the flow change can cause a separation of the nitrogen gas and the thy-chemical powder. In order to ensure the proper flow division of dry chemical at each tee, certain minimum pipe lengths must be observed when approaching a tee following a change in flow direction. These minimum pipe lengths are shown in Figure 44. NOTE: These minimum pipe lengths also apply to local- application systems. . Figure 4-5. Distribution Systems Requiring No Minimum Pipe Length 43.5 . Material for Pipe and Fittings All piping must be Schedule 40, hot-dipped-galvanized steel pipe, and all fittings must be, at a minimum, standard weight (1&)-lb. class). Eicamples of acceptable titling materials include hot-dipped-' galvanized malleable iron, ductile iron, or steel. Couplins and unions may be. used where necessary, and reducing bushings or reducing tees can be used for changes in pipe diameter. NOTE: Black steel pipe and fittings can be used in relatively noncorrosive atmospheres. UL EX-2153 4-5 November 1998 44 SOLVENT STORAGE ROOM EXAMPLE•• Asolvent storage room 14 feet long by 10 feet wide by 10 feet high is known to contain the following materials and maximum storage quantities. Flash Maximum Material (Degrees Ouanttty (Gallons) Acetone 3 60 Methyl Ethyl 16 60 Ketone. Toluene 40 60 The room has no uncloseable openings, and all the flammable liquids are stored in one-gallon metal containers. No dispensing of liquids is allowed in the room. The owner wants to protect this area with a dry-chemical system. 4-4.1 Hazard Analysis The objective of the fire suppression system is to detect and extinguish a flammable-liquid fire involving any of the materials stored in the room. Since the flammable liquids are stored in a room with no uncloseable openings, a total-flooding dry chemi- cal system will be designed for this application. The design analysis should start with a dear statement of the haz... II 10.O 'I II 5.4r- aids involved in the application. In general, the flammability, dassifi cation for a liquid is determined by its flash point NFPA 30, Flam- mable and Combustible Uquids Code, defines a combustible liquid as a liquid having a flash point at or above 100 degrees F (37.8 degrees C), and defines a flammable liquid as a matérial having a flash.point below 100 degrees F. Based on the data above, all of the materials stared in the room are flammable liquids. Following the hazard identification (i.e., flammable liquids), the next step would be to determine the applicability of dry chemical to fires in-the flammable materials being stored. This can only be ascertained from material safety data sheets supplied by the manu- fecturers of the flammables. These safety data sheets must be care- fully reviewed by the designer pnorto starting the system design. In our application, a review of the appropriate safety data sheets reveals that regular dry chemical (BC powder) will extinguish fires ir all o44 mate- rials being stared in the room. The severity of the hazard can be assessed in the following man- net. While it is obvious that the fuel loading is quite heavy in the storage room, the owner has taken all of the necessary steps to comply with the flammable liquid code (NFPA3O). The room is ventilated, and all wiring and equipment located in the room is suit- able for Class 1, Division 2 locations. The flammables are stored in small containers, and no dispensing is allowed in the room. Under these conditions, the most likely fire scenario would involve a fuel spill of up to one gallon (i.e., one container). Given these param- eters, it is unlikely that a flammable vapor and air mixture will de- velop in the room. Therefore, a dry chemical extinguishing system is appropriate for this application. LEGEND 50-LB CYLINDER WITH CONTROL CI HEAD. MOUNTING BRACKET, AND DISCHARGE ADAPTER —p DISCHARGE NOZZLE -0- DISCHARGE NOZZLE E) THERMOSTAT OR H.A.D. REMOTE MANUAL RELEASE Industrial Dry-Chemical Applications and Examples '.. II. Total-Flooding System Design Example 14 S UL EX-2153 W DIA TYP FOR ALL BRANCHES 1 DIA. PIPING A ISOMETRIC 25 CYLINDER Fri Figure 4-8. Solvent-Storage Room 4-7 November 1998 Applications and Examples Industrial Dry Chemical S 4-4.2 Nozzles Since the ceiling height (10 feet) i less than 12 feet, each total flooding nozzle can covera maximum surface area of 112.5 square feet (10.6 ft. by 10.6 ft.), ivith a longest side of 15 feet. The num- ber of nozzles is determined by successively dividing the length and width dimensions by the nozzle linear spacing (15 feet), rounding up the calculated quantities to the nearest whole num- bers, and then multiplying the calculated quantities. NOTE: The nozzle linear spacing for square areas is 15 feet. For rectangular areas, the nozzle has two linear spacings (e.g., 7.5 .feet and 15 feet). For estimation purposes in our example, it is more practical to use the square area linear spacing of 10.6 ft., even though the storage room has a rectangular cross-sectional area. Divide the length of the storage room by the nozzle's linear spac- ing and round up. Length = 1411. At 10.6 ft/nozzle = 1.0 or (rounding up) two nozzles (length- wise). Divide the width of the storage room by the nozzle's linear spac- ing and round up. Width = lOft. At 10.6 ft/nozzle = 1.06 or (rounding up) two nozzles (widthwise). Multiply the lengthwise and widthwise nozzle quantities to de- termine the number of nozzles required. No. of nozzles = I x 2=2 There are no special conditions such as excessive ventilation rates or uncloseable openings that necessitate additional quan- tities of dry chemical for fire-extinguishing purposes. Also, fire incident data suggests that the probability of fire in this applica- tion is low (although, should a fire occur and not be suppressed, the consequences would be catastrophic). Therefore, we will not use a reserve dry chemical extinguishing system. 4-4.3 Cylinders Each lND-25 cylinder can supply two total-flooding nozzles, and each lND-50 cylinder can supply four nozzles. Thus, one 25-lb. cylinder or one 50-lb. cylinder can be used to protect the solvent- storage room. We will use one 25-lb. cylinder because it is more cost-efficient to do so. In general, the number of cylinders fora total flooding application is determined by dividing the number of required nozzles by 4 (for nozzle quantities greater than 2). This determines the number of 504b. cylinders (or 45-lb. cylinders, where applicable). Any leftover or remainder nozzles in quantities of 2 can be supplied by a 25-lb. (or 21-lb., where applicable) cylinder. Thus, for our application, the number of 25-lb. cylinders can be calculated as follows: For 2 Nozzles At 2 Nozzles/25-lb. cylinder = One 50-lb. cylinder 4-4.4 Detection System The flammable liquids contained in the so1v8nt storage room are highly volatile and, in the event of a spill and subsequent ignition, the resulting fire would progress very rapidly and wixildl release a large quantity of heat. Thermostats, HADs, or Kidde KGR Rapid Response Fusible Links 'should be used for early d(jo rn order to reduce the size and duration of the fire, and also to rr*ilrvüe the subsequent vaporization of fuel as a result of the fire. WARNING ELECTRICAL WIRING AND EQUIPMENT LOCATED IN- SIDE ROOMS USED FOR FLAMMABLE-UQUIDSTOR- AGE SHALL BE SUITABLE FOR CLASS-I, DIVISION-2 LOCATIONS. THERMOSTATS SHALL BE RATED FOR USE IN CLASSIFIED AREAS, AND ALL WIRING TO ThESE COMPONENTS SHALLCONFORMTO ThE PRO- ViSIONS OF NFPA70, NATIONAL ELECTRICAL CODE, FOR CLASS-I, DlV1SlON-2LOCAflONS.ANYSYSTEM CONTROL HEAD WITH AMICROSWITCH IS NOT SUIT- ABLE FOR USE INACLASSIF1ED AREA. The number of detectors is determined by successively divid- ing the enclosure's length and width by the detector's linear spacing (20 feet; 15'-l(" for an FM application with HADs), round- ing up the calculated quantities to the nearest whole numbers, and then multiplying the calculated quantities. Assuming that there is no FM approval required, divide the length of the storage room by the detector's linear spacing and round up. Length= 1511. At 20 11./detector = 0.8 or (rounding up) I detector (lengthwise). Divide the width of the storage room by the deteor's linear spac- ing and round up. Width =, 10 ft. At 20 ft/detector = 0.5 or (rounding up) I detector (widthwise). Multiply the lengthwise and widthwise detector quantities to de- termine the number of detectors required. No. of detectors = I x 1 = I The type of control head (either electric or pneumatic) for the cylinder will be dictated by the choice of either an electric (ther- mostatic) or a pneumatic (HAD) detector. CAUTION ALL SYSTEMS WITH ELECTRIC ACTUATION MUST BE PROVIDED WITH A CONTINUOUS, SUPERVISED BACKUP POWER SOURCE CAPABLE OF OPERAT- ING THE SYSTEM FOR AT LEAST 24 HOURS, UN- LESS THIS REQUIREMENT IS EXPLICITLY WAIVED BY THE AUTHORITY HAVING JURISDICTION. The layout of the dry-chemical system is shown in Figure. 4-8. The piping to the nozzles must fall within the parameters shown in Figure 4-7. To complete the system design, the designer must determine what is required to stop the ventilation upon dry-chemi- cal discharge, and would also need to review any other job re- quirements, such as alarm notification. S_ The number of nozzles required for theextinguishing system is deter- mined by dividing the solvent storage room into volume segments. We will use the total-flooding nozzle, PIN 83-100005.001. A nozzle will be ceiling mounted and centered in each of the protected volume seg- merits. The number of nozzles required is as follows. UL EX-2153 4-8 November 1998