Loading...
HomeMy WebLinkAbout2180 RUTHERFORD RD; ; FA080052; Permit11/10/2020 FA080052 Permit Data City of Carlsbad Fire. Alarm Permit Permit No: FA080052 2180 RUTHERFORD Job Address: Status: ISSUED RD Permit Type: FALARM Applied 8/13/2008 Parcel No: 2120702500 • Approved: 8/13/2008 Lot #: 0 Reference No.: Issued: 8/13/2008 PC #: • Inspector: Project Title: CALLAWAY GOLF TWO FIRE ALARM INBSPECTIONS c $65/EA Applicant: NOVA SECURITY SUITE 104 10744 ROCKVILL ST SANTEE, CA 619-448-3007 Owner: CALLAWAY GOLF CO C/O DUCHARME MCMILLEN & ASSOC INC 20830 N TATUM BLVD #240 PHOENIX AZ - Fees ($)• Add'I Fees ($) Total ($) Balance($) 130 0 130 0 1/1 FILL L i-e"'I f=Aogoo5l CALAWAY GOLF HQ BUILDING 2180 RUTFIERFORD ROAD, CARLSBAD,CA Z.Fire Alarm Submittal 07-28-08 wil vile ¼ %¼%" ç i' of •% it".% tit "'I", et tle of 11 1 i, ION, "IIA .tl•" C • wi"olef vic";cV. low If vot %S Submitted By; NVA SECURITY 10744 Rockvill St. Suite 104 Santee, CA. 92071 619-448-3007 Cont. Lic. C-10 # 802053 -lei 7- AP9D AS SUBMITTED FIREW?MNT E CALAWAY GOLF 00 HQ BUILDING Fire Alarm Submittal Equipment List Go Description Fire Alarm Panel Fire Alarm Annunciator Fire Alarm Power Supply Smoke Detector Manual Pull Station Addressable Input Module Addressable Relay Module Strobe Multi-cd cig mnt Horn/Strobe Multi-cd clg mnt Model Manufacture CSFM# 5820XL SILENT KNIGHT 7170-0559:135 5860 SILENT KNIGHT 7170-0559:135 5496 SILENT KNIGHT 7170-0559:135 SD505-APS SILENT KNIGHT 7272-0559:129 SD500-PS SILENT KNIGHT 7150-0559:136 SD500-AIM SILENT KNIGHT 7300-0559:132 SDSOO-ARM SILENT KNIGHT 7300-0559:132 RSS-24MCC W}IEELOCK 7125-0785:141 AS-24MCC W.HEELOCK 7125-0785:131 Lot Wire 18/2 Cond. (Initiation) Lot Wire 14/2 Cond. (Notification) Lot Wire 18/4 Cond. (Annunciator) Lot Wire 2 #14 THWN (Underground) 1 Improvements in SKSS software deliver five times faster uploads/downloads Two built-in Form C programmable relays rated at 2.5 amps at 27.4 VDC. Supports sounder bases 6 amp power supply and maximum charging capacity of 35 amp hours (An additional cabinet enclosure is required for batteries in excess of 18 amp hours) Programmable date setting for Daylight Saving Time Plex-1 door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing single button operation of the reset and silence functions Electrical Specifications Primary AC: 120 VRMS at 50/60 Hz, 2.5A or 240 VRMS at 50/60 Hz, 1.4A Total Accessory Load: 6A @ 27.4 VDC, power-limited Standby Current: 215 mA Alarm Current: 385 mA Flexput Circuits: Six programmable circuits which can be programmed individually as: Notification circuits: 3A @ 27.4 VDC per circuit, power-limited Auxiliary, power circuits: 3A © 27.4 VDC per circuit, power-limited Initiation Circuits: 100 mA © 27.4 VDC per circuit, power limited Mechanical Specifications Flush Mount Dimensions: 14.5"W x 24.75"H x 3.9"D (36.8 W 62.9 H 9.8 D cm Model 5820XL Overall Dimensions: 16.2W x 26.4H x 4.2'D (40.6 W x 67 H x 11.8 D cm) Weight: 28 Ibs: (12.8 kg) Color Red Battery Charging Capacity: 7:0-35 AH Battery Size: 18 AH max allowed in control panel cabinet. Larger capacity batteries can be housed in RBB accessory. cabinet. Telephone Requirements: FCC Part IS and Part 68 approved Type of Jack: RJ3IX (two required) STL.ENT KNIGHT byHnèywel1 S Intelli Knight® Model 5820XL Addressable Fire Alarm Control System The lntelliKnight System is the easy way to make the most of fire alarm technology. lntelliKnight 5820XL is the first fire alarm system to provide you with revolutionary value and performance in addressable sensing technology. The 5820XLFACP offers exclusive, built-in digital communication, distributed intelligent power, a modular design and an expanded, easyto use interface. Powerful features such as drift compensation and maintenance alert are, delivered in this poWerful FACP from Silent Knight. For more information about the 5820XL system; or to locate your nearest source, please call 1-806-446-6444, or in Minnesota, call 763-493-6435. Description 5820XL performs drift compensation and calibration checks on each of the sensors in the system. The basic 5820XL system can be expanded by adding modules such as 5860 remote annunciator, 5815XL signalling line circuit expander, 5824 serial/parallel printer interface module (for printing system reports), and 5895XL intelligent power module. 5820XL also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. L 0 Features Up to 508 addressable points Uses standard wire—no shielded or twisted pair required Built-in digital communicator Central station reporting by point or by zone Built-in synchronization for appliances from AMSECO®, Gentex®, Faraday, System Sensor, and Wheelock® Flexput" I/O circuits Supports Class B (Style 4) and Class A (Style 6) configuration for SLC, SBUS, and Flexput circuits Distributed, intelligent power Drift compensation 13 pre-programmed output cadences (including ANSI-3.41) and 4 programmable outputs Built-in annunciator with 80-character LCD display RS-485 bus provides communication to system accessories Built-in RS-232 aridUSB interface for programming via PC Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC IntelliKnight Model 5820XL S Addressable Fire Alarm Control Panel Indicator Lights General Alarm (Red): Flashes when in alarm; solid when alarm silenced Supervisory (Yellow): Flashes when a supervisory condition exists; solid when supervisory silenced System Troubles (Yellow): Flashes when a trouble condition exists; solid when trouble silenced System Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared System Power (Green): Flashes for AC failure; solid when power systems are normal System Application 5820XL has one built-in signalling line circuit (SLC) which supports 127 devices. Three additional loops can be added using the 5815XL SLC expanders to increase overall capacity to 508 devices. The 5820XL SLC loops support multiple device types, including: Addressable photoelectric smoke detector Addressable ionization smoke detector Addressable heat sensor Addressable duct smoke detector Contact module Relay output module Addressable notification module The following advanced sensor capabilities are available with 5820XL: Automatic drift compensation Maintenance alert Built-in sensor test to comply with NFPA 72 8alibration testing requirements 5820XL features a 6 amp power supply and maximum battery charging capacity of 35 amp hours.Aru additional cabinet enclosure (PN RBB) is required for batteries in excess of 18 amp hours. Flexput circuits on 5820XL control can be individually programmed to function as notification circuits, auxiliary power outputs, or initiation circuits that support both 2- and 4-wire smoke detectors. The 5820XL system operates on non- twisted, unshielded cable when wired in compliance with standard wiring practices as called out in the National Electric Code 760-51 specifications for power-limited fire protective signalling cables. No special wiring is required. 5820XL provides 13 preset notification cadence patterns (including ANSI 3.41) and four user programmable selections for fire alarm notification. Two programmable general purpose Form C relay outputs are provided on 5820XL. Additionally, the lntelliknight system features a built-in walk test and auto- programming. Its innovative, dead-front cabinet design allows for flush or surface mounting. System maintenance is easy to perform. User Interface The 5820XL built-in annunciator with 80 character LCD display and large easy-to-use tactile touchpad can be used for system operation, programming and maintenance. It has five LEDs for alarm, supervisory, system trouble, system silenced and system power. System operations include silencing alarms and troubles, resetting alarms and the display of' alarm troubles and memory. The system's non-volatile event history buffer stores 1000 events for viewing from the built-in or remote annunciator. System operation can be initiated with a mechanical firefighter's key or a valid 4- to 7-digit Operator's code. Programming' The lntelliKniht system offers several options to simplify and speed up programming. The JumpStartV feature minimizes programming required to start a new system. The built-in keypad and 5860 remote annunciator give on-site access to all programming. You can also program remotely using the 5660 Silent Knight Software Suite, which is Windows0- based software. Built-In Digital Communicator 5820XL features a built-in UL listed digital communicator for remote reporting of system activity and system programming. The communicator has the ability to seize two telephone lines to report alarms and troubles to a monitoring facility. The communicator supervises two phone lines and will activate a trouble signal if a line failure is sustained for more than 45 seconds. Other communication features include: retry if communication fails, two phone number capability, download phone number capability and Touch-Tone or rotary dialing. The communicator is compatible with SIA and Ademco Contact ID. The format is selectable by account number. Approvals NFPA 13, NFPA 15, NFPA 16, NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterfiow, sprinkler supervisory (DACT non-coded) signalling services. Other Approvals: UL Listed; CSFM 7170-0559: 135; MEA 429-92-E Vol. VI; FM Approved ~-1 teUXnht Model 5820XL Addressable Fire Alarm Control Panel 4 4 S : rL C> o> tC> CCC S SLC Detectors 5820XL devices feature-a low profile design and EEprom addressing. EEprom addressing prevents water intrusion problems via the back of the sensor and eliminates mechanical failures related to decade switches. S0505-APS Addressable photoelectric smoke detector. SD505-AIS Addressable ionization smoke detector. SD505-AHS Absolute temperature heat detector that goes into alarm immediately if the temperature exceeds the programmable trip point. Trip point range from 135°F-1 50°F(0°C-37°C). S0505-SAB Six inch base for use with detector heads SD505-APS, SD505-AIS, and SD505-AHS. SD505-4A8 Four inch base for use with detector heads S0505-APS. SD505-AIS, and SD505-AHS. SDSOS-6SB Six-inch sounder base for use with existing sensor and base. Operates in single and multi-station modes and/or as a system sounder. Requires 2 additional wires for power. S0505-61B Six-inch isolator base for use with existing base and the SD505-APS, SD505-AIS, and SD505-AHS sensors. Provides isolation for style 7 circuits. SD505-SRB Six-inch relay base for use with existing sensor and base. Provides one Form C contact. SDSOS-ADH Duct housing that detects smoke in HVAC ducts. 5D505-ADHR Duct detector base with relay. Provides Form C alarm contact. For use with SD505-APS and SD505-AIS sensors. Compatible with S0505-DTS remote test switch. SD500-PS/SD500-PSDA S0500-PS is a single action pull station and SD500-PSDA is a dual action pull station. SLC Modules SD 500-AIM Dry contact input module for use with normally open dry contacts. It features an indicator LED to show alarmstatus. SD500-MIM Mini dry contact input module is a small version of the SDSOO-AIM. For use with pull stations and other normally open dry contact inputs. SDSOO-ANM Addressable notification module providing a single Class A or Class B notification circuit on the SLC. SD500-ARM Addressable relay module. Features 2 Form C output relays. Provides .indicator LED to show output status. SD500-SDM Two-wire detector input module. Allows for the connection of conventional 2-wire detectors on the SLC loop. Requires two additional wires for power. SD500-LIM A short circuit isolator module for SLC devices. When a short occurs on the SLC loop, it is detected as a trouble, but all SLC devices protected by the isolator module continue to operate. SDSOO-LED An LED driver module capable of driving 80 LEDs. Use up to 40 modules per SLC loop and up to 100 SD500-LED modules per system. S-BUS Accessories 58601R Remote Fire Annunciator Features the same 80 character backlit LCD display keypad and firefighter's keyswitch as the 5820XL. 5860 is gray and 5860R is red. 581 SXL Signal Line Circuit Expander The SLC expander is used to add more addressable devices to the lntelliKnight system. 5820XL supports three 5815XLs. Each 581 5X can support 127 devices. 5895XL Intelligent Power Module Adds 6 amps of power, 6 Flexput 110 circuits and 2 Form C relay circuits to a 5820XL system. 5496 Intelligent Power Module A 6 amp notification power expander that provides four power-limited notifi- cation appliance circuit outputs. 5880 LED/I0 Module Features 40 LED outputs, 8 normally open dry contact and one piezo 5865-3 and 5865-4 Remote LED Annunciator Features 30 programmable LED (15 red and 15 yellow) outputs, and a piezo sounder. The 5865-4 adds a silence and reset switch to the package. 5883 Relay Board Features 10 general purpose Form C relays. Used with 5880 module. 5824 SeriallParallel Printer Interface Module Provides one parallel and one RS-232 serial port for connecting a printer to the 5820XL. Use to print a real-time log of system events, detector status reports, and event history. Interfaces with building control system. Miscellaneous Accessories 5660 Silent Knight Software Suite (SKSS) User-friendly Windows software for remote programming of 5820XLs using a PC. Upload and view panel account information, event history, and detector status. 5670 Silent Knight Software Suite (SKSS) Powerful end-user facility management software allows viewing of detector status and event history via modem or direct connection. Plex-1 Dead front cabinet door with clear window to limit access to the FACP. RBB Remote battery box accessory cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16"Wx10"Hx6D 406 mm W x 254 mm H x 152 mm D) 5D505-DTS Remote test switch. Used with SD505-ADHR. Provides remote key operated test function and annunciation of detector alarm. [1 D SILENT This document is not intended to be used for installation purposes. We try to MI keep our product information up-to-dale and accurate. We cannot cover all I LI I specific ppt;ca(ions or anticipate all requirements. All specifications are subject to change without notice. For more informaton, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, MN 55369-4927. Phone: (800) 328-0103. Fax: (763) 493-6475. lntelliKnight & JumpStart are Registered Trademarks of Silent Kn:ght Flexput is a Trademark of Silent Knight MADE IN AMERICA FORM# 350210 Rev E, 04106 Copyright P 2006 Silent Kngiit Before You Begin Installing 3.6.2 Current Draw Worksheet Use Table 3-1 to determine current requirements diring alarm/battery standby operation You can install up 99 devices per loop (1016 max per panel). Copy this section if additional space is required. Table 3-1: Current Draw Worksheet Device # of Devices Current per Device -7 Standby Current Alarm Current For each device use this tormula: 1 his column A I his column = Current per number ol devices. lntelliKnight 5820XL Fire Panel (Current draw from battery) [Standby: 215 mA 215 mA [im: 385 mA . 385 mA Addressable SLC Devices 80500-AIM (508 Max.), . Standby. Alarm: 0.55 mA . mA mA SDSOO-MIM mA mA SD500-PS S0500-ARM mA mA 50505-AIlS mA mA S0505-AIS mA mA 8D505-APS mA mA SDSOO-ANM (508 max.)1 Aux. Pwr Standby: 8 mA mA Alarm:60 mA mA SLC Standby Alarm: .55 mA mA m SD500-SDM (508 max.)1 SLC Standby Alarm: .55 mA A m m Aux. Pwr Standby: 20 mA mA Alarm: lOG mA mA 81)500-LED (100 Max.), Aux. Pwr Standby: 10 mA mA Alarm: 220 mA mA LED: 10 mA mA mA SLC Standby Alarm: 0.55 mA m A I SLC Accessory Bases . 80505-6RB (508 max.) Standby Alsam: .082 mA mA mA Sl)505-G.SB (508 Aux. Pwr ) Standby: I. mA mA Alarm: 32 mA mA SLC Standby Alarm: .082 mA m A ifl A SDSOS-ADHR (508 max.) Aux. Pwr Standby: 35 mA mA Alarm: 75 mA 2 mA SL Standby Alarm: .082 mA mn, mA 80505-DTS (508 max.) None, included with SL)505-AE)HR worst case. SD505-ADFl (508 max.) None, included with detector current. SLC Isolator Devices SDSOS-L[M (1024 max.) Standby Alarm 0.092 mA mA mA SD-O- --61B 08 Max.) Accessories Modules 5815XL SLC Expander 1 (3 ') I.Standby Alarm: 55 mA mA mA 0 151209 3-7 lntelliKnight 5820XL Installation Manual Device # of Devices Current per Device Standby Current Alarm Current 5860 Remote Fire Alarm Annunciator standby: 20 mA mA Alarm: 25 mA mA 5824 Serial Parallel Printer intcrLice Module ''max ' .' Standby Alarm: 45 mA mA mA 5895XL lntelliKnight Power Expander (8 max.) Standby Alarm: 10 mA mA mA 5496 Intelligent Power Module Standby Alarm: tO mA mA mA 5865-4 LEI) Annunciator (with reset and silence switches) (8 max.) Standby: 35 mA mA Alarm: 145 mA mA - 865-3 LED Annunciator Standby: 35 mA mA Alarm: 145 mA mA 58 tt0 LED I 0 Module Standby: 35 mA mA Alarm: 200 mA mA 5883 Relay Interface (32 max.) Standby: 0 mA mA Alarm: 220 mA (22 mA per relay) mA 'tidal System Current Auxiliary Devices3 - Refer to devices unnua1 for current rating. Alarm Standby: mA mA mA Alarm Standby: mA mA mA Alarm Standby: mA mA mA Alarm Standby: mA mA mA Auxiliaiv Devices current Alarm: mA mA Alarm: mA mA Alarm: mA mA Alarm: mA mA Notification Appliances Current mA Total current ratings of all devices in system (line A + line B + C) mA mA Total current ratings converted to amperes (line I) x.001). A A Number of standby hours (24 or 60 for NFPA 72, chapter 1. 1-5.2.5): H Multiply lines E and F. Total standby AH Ali Alarm sounding period in hours. (For example, 5 minutes =.0833 hours) H Multiply lines E and H. 'Jidal alarm All All 4 Total ampere hours Add lines ( and 1. required All I. Total does not include isolator devices or accessory bases. Ii using 24 VDC aux power only. No standby or alarm current for battery calculation if using 24 VAC. 120 VAC or 240 VAC. If using door holders, you do not need to consider door holder current for alarm battery standby, because power is removed during that time. However, during normal operation, door holders draw current and must be included in the 6.OA total current that can be drawn from the panel. Use next size battery with capacity greater than required. 3-8 151209 S A I) C E (3 H Before You Begin Installing 3.6.3 Maximum Battery Standby Load Table 3-2 shows the maximum battery standby load for the 5820XL based on 24 and GO hours of standby. The standby load calculations of line D in the Current Draw Calculation Worksheet (Table 3-1) must be less than the number shown in Table 3-2 for the battery size used and standby hours required. Table 3-2: Maximum Battery Standby Load Rechargeable Battery Size Max. Load for 24 hrs. Standby, 5 mins. Alarm Max. Load for 60 hrs. Standby, 5 mlns. Alarm 7AH 270 mA 105 mA 12 All 475 mA 190 mA 18 All 685 mA 270 mA 35 All 1.3A 540 mA * Required for NFP.4 72AuxiliaryProfectc'dFire .4larin systems for Fire .4/arm Service (City Box) and Remote Sicuzion Protected Fire A/ann systems (Polari), Reversal) and Digital .41armn Co,nmnuniccaor'frans,niiter D.4CT). Silent Knight does not support the use of batteries smaller than those listed in Table 3-2. If you use a batten' too small for the installation, the system could overload the batteni resulting in the installation having less than the required 24 hours standby power. Use Table 3-2 to calculate the correct battery amperes hour rating needed for your installation. 3.7 Installation Tasks Overview This section provides a chart listing tasks that need to be performed when installing the lntelliKnight 5820XL system. The chart is intended to be a handy way for you to make sure you have completed all necessary tasks. Unless noted, these tasks do not have to be performed in the order they are listed here. Important: Connect and address SLC devices before running JumpStart. Task See Sec. (for more info.) Main Panel Hardware Installation Mount the control panel cabinet. 4.1 Connect AC. 4.2 fl Connect phone lines. 4.11 Install 581 SXL SLC expander modules (if needed). Required if more than 127 SLC devices are used. 4.4 0 Install 5860 Remote Fire Alarm Annunciator modules if used. 4.5 J Install 5865 or LED Annunciator modules if used. 4.9 Install 5880 LED 10 module if customized LED annunciation will be used. 4.8 0 Install notification appliances. 4.13 Install auxiliary power devices (if used). . 4. 13.5 0 If using a printer, install the 5824 Serial Parallel Printer lnterthce Module. 4.7 0. Connect batteries (typically last step). 4.3 151209 3-9 S FIRE SYSTEM AcEs&'I 1 5496 Intelligent Power Module /t ' A dynamic combination of power and intelligence for your notification expansion needs. The Model 5496 Intelligent Power Module by Silent Knight is the most- powerful and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from Gentex®, System Sensor®, Faraday, AMSECO and Wheelock® - what you need to drive power-hungry components like ADA notification appliances. The 5496's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. For the most sophisticated and cost-effective notification power supply available, you need Model 5496. Call Silent Knight today for more information at 1-800-446-6444. Model 5496 3amps per output circuit Intelligent Power Module Ground fault detector, The model 5496 is a 6 amp notification Communicates to the FACP via 4- ORION power expander that provides its own wire SBUS (wire runs up to 6000 ft) 3 AC power connection, battery charging AC loss delay option shuts off power circuit and backup battery for use with to non essential high current r'4 ire and security controls such as the accessories like magnetic door lntelliXnight Model 5808 Fire Control holders rvj /Communicator. The 5496 is the cost Lightweight design adds to ease of effective solution for powering installation and reduces shipping notification appliances required by the costs tJt).cj2f Americans with Disabilities Act (ADA) UL 864,1481 & 1971 listed The 5496 has built-in ANSI cadence pattern which can upgrade older ANSI Cadence pattern output control panels that lack cadence capability built-in ) j capability. The Output circuits can be Specifications t b programmed as Notification Appliance AC Input 120 VAC at 27 A Circuits or as Auxiliary Power Output 24 VOC at 6 amps (configurable for, constant, resettable, or door holder power). . Current: Model 5496 Intelligent. Features Standby 40 mA Alarm 160 mA Power Module UL Listed for 6 amps of notification power Notification/Aux. Power supply's advanced switch Power circuits: 4 . Ambient Temp.: 3 to 120'F O to 49-G mode design reduces damaging Output heat and manages power up to 50% configuration: 2 Class A (Style Z) Dimensions: 12.25" W x 16" H x more efficiently than other systems 4 Class B (Style Y) . 3' 0 (30.89 cm W Built-in synchronization for . (I Class A& 2 Class B) x 40.64 cm H x 7.62 0 cm) appliances from AMSECO, Gentex°, Faraday, System Sensor'!, and Amps per Approvals: UL Wheelocka output circuit: 3.0 (6.0 amps total) CSFM 24 VDC filtered output voltage Notification MEA 429-92•E vol. XIV Four power-limited notification circuit output: 20.4 to 27.3 VOC outputs; 2 Class A or 4 Class B, or 1 @ 3.0 amps each. Class A and 2 Class B 4.7 k* EOL resistor required NACs are programmable as on each Class B SJLTNT Notification Appliance Circuits, or as circuit auxiliary power to be used as Battterr charging KNIGHT constant, resettable, or door holder capacity: 35.OAH power by Honevwtilf Firepower 5496 Distributed Power Module :4q Engineering Specifications The contractor shall supply a power module compatible with the Silent Knight FACP. The power module must have 6.0 amps of output power. The power module shall connect to the main FACP via an RS 485 system bus (SBUS). The Outputs shall be programmable as Notification Appliance Circuits, or as Auxiliary Power (configurable for, constant, resettable, or door holder power). The power module shall have four separate outputs. The power module AS 485 bus shall be optically isolated providing ground loop isolation and transient protection. .4 oLit$ pmqraffirnable as t4iftrttit Appli.nc Co-cuitsi or, as krxiliary Power output Oupa 2 Outur. 3 O.utrit 4 SBUS c'r1iuiic2tkn ip SiFi KPht FI&P Auxiliary paver can be prc9rnmmd to be. conslant rife, or door hakler Càmpatible FACPs lntelliKnight 5700 lrttelliKnight 5808 lntelliKnight 5820XL D SiLNT This document is not intended to be used for installation purposes. We try MADE IN AMERICA to keep our product information up-to-date and accurate. We cannot cover KNIGHT all specific applications or anticipate all requirements. All specifications are FORM# 350387 Rev C. 9107 subject to change without notice. For more information, contact Silent 0 2007 Honeywell International Inc. 4or.enNeH Knight 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Phone: (800) 328-0103, Fax: (763) 493-6475. 0 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIAlS LISTING PROGRAM LISTING SERVICE E LISTING No. 7170-0559:135 Page 1 of 2 CATEGORY: Control Unit (High-Rise) LISTEE: Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: Michael Mclsaac (763) 493-6400 FAX (763) 391-5464 DESIGN: Models 5820, *5820XL, IFP-1000 Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterflow, water releasing and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 5820, 5820XL, IFP-1000 4058200P 5815/5815XL 7628 lntelliknight 5820 5860/5860R/RA-1000 5496 5824 5895/5895XURPS-1 000 5865-3/5965-4 5880 5883 SD500-ANM SD500-LIM SD505-61B SD-500 SDM RA-100 3158 5220 *122365 *AB33 *5897 *5898 *058601 Control Units Motherboard Analog Loop Expander EOL Resistor Enclosure Annunciator Power Module Serial/Parallel Interface Power Expander/Supply LED Annunciator LED 10 Module Relay Interface Board Addressable Notification Module Line Isolation Module Isolation Base Smoke Detector Module Remote Reverse Polarity Module Direct Connect Module Enclosure Battery Cabinet Power Supplies User Interface RATING: INSTALLATION: MARKING 120 VAC Primary, 24 VDC Secondary In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Rev. 08-17-2008 jw 0 Listing No. 7170-0559:135 Page 2 of 2 S APPROVAL: Listed as control units for use in high-rise structures when used in conjunction with Model SKE-360 Voice-Tone Evacuation Unit (CSFM Listing No. 6912-0559:122); EVAX Audio Adjunct System Models EVAX-25 (CSFM Listing No. 06911-1446:100), EVAX-50 or EVAX- 50E (CSFM Listing No. 06911-1446:102); EVX-2ZA or EVX-4Z Zone Splitters (CSFM Listing No. 06912-1446:101); HMX-MP or HMX-DP Voice Evacuation System (CSFM Listing No. 06911-1446:103), two-way firefighter telephone and separately listed electrically and functionally compatible initiating and indicating devices. Also suitable for non-high-rise applications where the voice evacuation and two-way firefighter telephone are not required. Refer to listee's Installation Instruction Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 90' Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. S Rev. 08-17-2008 jw This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results• and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable infrmation sources. Date Issued: JUNE 6, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division INTELUKNIGI-4T ACCESSORY Addressable Photoelectric Type Smoke Detector Detect smoldering fires quickly and get help fast with lntelliKnight® photoelectric smoke detectors. lntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-APS photoelectric detector has a unique address, which is recognized by the lntelfiknight panel. No precious seconds are wasted in determining location of an alarm. The SD505-APS compensates automatically for contamination in the environment. And detector testing is simple—even from a remote site. Like other lntelliKnight detector models, the SD505-APS offers a low profile for pleasing aesthetics. The lntelliKnight family of detectors has been designed to use a common base, Model S0505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors—easy installation, stable operation, RF/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. S 0 Model SD505-APS Analog / Addressable Photoelectric Type Smoke Detector The SD505-APS is particularly suited to detecting dense smoke typical of fires involving materials such as soft furnishings, plastic, foam or other similar materials which tend to smolder and produce large visible particles. The detector features automatic compensation for contamination and a simple detector calibration test procedure that can be run from the panel or remotely (using the WindowsTm based downloading software). Operation The S0505-APS units made up of an LED light source and a silicon photo diode receiving element. In a normal standby condition, the receiving element receives no light from the pulsing light source. In the event or fire, smoke enters the detector and light is reflected from the smoke particles to the receiving element. The light received is converted into an electronic signal. Under normal conditions, the status LED blinks approximately every 15 seconds, indicating that the head is communicating with the loop. The LED lights continuously during the alarm period. Features Low profile, 2 inches, including base Simple and reliable addressing without mechanical switches Automatic compensation for sensor contamination Built-in fire test feature Simple detector calibration testing through the control panel or remotely through a WindowsTi based computer software. Vandal-resistance locking features Field cleanable UL listed, meets NFPA 72 Ch 7 requirements CSFM approved MEA approved FM Approved SD505-APS Smoke Detector Specifications Operating Voltage: 17-41 VOC Current Consumption: Standby: .55 mA Alarm: .55 mA Ambient Temperature: 32°F to 120°F (0°C to 49°C) Mounting: 4' Square. 4 OCT. Single gang mud ring Relative Humidity: 85% noncondensing Air Velocity: 0 . 300 FPM Compatible Bases: SD505-6AB (Sold Separately) (6 Base) S0505-4AB (4 Base) DSILENT KNIGHT by Honeywell IN ELLjKNIGHT ACCESSORY Model SD505-APS Addressable Photoelectric Type PF14 Smoke Detector S Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505-APS. The combination detector head, and twist-lock base, shall be UL6' listed compatible with Silent Knight's lntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight S0505-AIS Ionization Smoke Detector, or SD505- AHS Heat Detector. Base shall be the appropriate twist-lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505-APS shall automatically, perform a functional testof the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. Diameter - 3-15116" S., 0 / ... .4 / \•,. - / Height a 2 inches. including base Model 8D505-6AB Detector Base Model SD505-APS Detector Head (front view) (front view) 0 D SILENT This document is not intended to be used for Installation purposes. We try to KNIGH T keep our product information up-to-date and accurate. We cannot cover all %LI'.JIi & specific applications or anticipate all requirements. All specifications are subject to change without notice. For more Information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Phone: (800) 328-0103, Fax: (763) 493-6475. MADE IN AMERICA FORM# 350225 Rev C.. 05/05 Copyright © 2005 Silent Knight CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 10 LISTING No. 7272-0559:129 Page 1 of I CATEGORY: Photoelectric Smoke Detector LISTEE: Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: *Michael Mc Isaac (763) 493-6400 FAX (763) 391-5464. DESIGN: Model SD505-APS analog addressable photoelectric type smoke detectorwith model SD505- 4AB and SD505-6AB bases. Unit consists of resistors, capacitors, diodes, transistors, LED, photo diode, mounted on a printed wiring board inside an enclosure. Refer to listee's data sheet for additional detailed product, description and operational considerations. RATING: 39.5 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detector for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7272-0410:149 'Rev. 06-13-2006 This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 6, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division 0 Addressable Heat Detector lntelliKnight® addressable heat detectors combine accurate heat detection with pin-point location ID. An essential combination for any installation. lntelliKnight heat detectors are an essential component in virtually any InteIliKnight installation. The lntelliKnigh t panel recognizes each detector by its specific address, so precious seconds are not wasted in determini n g location of an alarm. Like other lntelliKnight detector models, the SD505-AHS offers a low profile for pleasing aesthetics. The lntelliKnight family of detectors has been designed to use a common base, Model S0505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight detectors—easy installation, stable operation, RF/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. Model SD505-AHS Addressable Heat Detector . The SD505-AHS is a heat detector suited to virtually any commercial setting. The SD505-AHS is an absolute temperature device. This means that it responds in alarm if the temperature goes above the trip point (programmed at the panel). If the temperature exceeds the trip point (programmed at the panel), an alarm occurs. The status LED lights continuously during the alarm period. Under normal conditions, the status LED blinks approximately every 15 seconds, indicating that the head is communicating with the loop. Features Low profile, 2 inches, including base Absolute temperature device Simple and reliable addressing Uses digital communication protocol The SD505-AHS is UL Listed and meets the requirements outlined in NFPA 72 Inspection Testing and Maintenance, Chapter 7. CFSM listed MEA listed FM approved DSILENT KNIGHT ® AHonIeNCompany SD505-AHS Heat Detector Specifications Operating Voltage: 17 to 41 VDC Current Consumption: Standby: .55 mA Alarm: .55 mA Detection Temperature Range: 135°F to 150CF (57°C TO 65CC) Ambient Temperature: 32°F to 100°F (0°C to 37°C) Mounting: 4" SOft 4" OCT Single gang mud ring Rated Spacing: 70' between sensors on srnoo:ri ceilings. Compatible Bases: S0505-6AB (Sold Separately) (6 Base) SD505-4AB (4' Base) The SD505-AHS provides accurate temperature measurement data to the fire alarm control panel. This heat detector is particularly suited to environments where smoke detectors cannot be used because of the presence of steam or cooking fumes, such as in a kitchen. Operation The SD505-AHS unit is made up of an externally mounted thermistor with a specially designed cover that protects the thermistor while allowing maximum air flow. The thermistor reads the temperature from the air it takes in. It then transmits a signal representing the temperature to the lntelliKnight panel. Model SD505-AHS Addressable Heat Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable heat detector Silent Knight SD505-AHS. The combination detector head, and twist-lock base, shall be UL® listed compatible with Silent Knight's lntelliKnight fire alarm control panels. The base shall permit direct interchange with Silent SD505-APS Photoelectric Smoke Detector, or SD505-AlS Ionization Smoke Detector. Base shall be the appropriate twist-lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset switch. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field removable when not required. Voltage and RF/transient suppression techniques shall be employed to minimize false alarm potential. 4 Diameter = 5-15/16 Diameter = 3-15/16" 14 S Height = 2 inches, including base DSILENT 1 'n -' Model SD505-6AB Detector Base (Front View) Model SD505-AHS Detector Head (Front View) D SILENT KNIGHT • A Hanepaiul Company 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 763-493-6435 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com MADE IN AMERICA FORM# 350229, Rev. 09.03 Copyright © 2003 Silent Kni;ni LISTING No. CATEGORY: LISTEE: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7270-0559:127 Page 1 of I Heat Detector Silent Knight Security, 7550 Meridian Circle, Maple Grove MN 55369-4927 Contact Michael Mc Isaac (763) 493-6400 FAX (763) 391-5464 S DESIGN: Model S0505-AHS electronic fixed temperature heat detector (analog) with Models SD505- 4AB and 5D505-6AB bases. Unit consists of resistors, capacitors, diodes, transistors, LED, thermistors, mounted on a printed wiring board inside an enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 39.5 VDC Temperature Range: 134°F - 149°F INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical/temperature rating and UL label. APPROVAL: Listed as heat detector for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7270-0410:147 'Rev. 06-12-2006 This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational. requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 6, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division .c. SD500-PS and SD500-PSDA Addressable Pull-Station lntelliKnight's addreSsable pull stations combine fast response with pin-point location ID. The SD500-PS and SD500-PSDA are a single action or dual action addressable manual fire alarm pull station for use with Silent KnighVs lntelliKnight fire control panel. Extremely easy to operate, the SD500-PS/PSDA provides a fast and practical means of manually Initiating a fire alarm signal. The lntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. The SD500-PS/PSDA mounts to a single gang box and features a rugged metal construction thatlasts and lasts. Combine all this with the features you've come to expect from Silent Knight - easy installation and stable operation and it adds up to a flexible solution for all your fire protection needs. Model SD500-PS& I • Extremely easy to Operate SD500-PSDA Addressable Pull- Station The SD500-PS is a single action addressable fire pull station, and the SD500--PSDA is a dual action addressable fire pull station. The SD500-PS/PSDA feature rugged metal construction A terminal strip on back of the pull station allows interconnection of the pull station to. the SLC of an lntelliKnight control panel. The SD500-PS/PSDA is designed for indoor use in non- explosive environments. The normally open initiating point contacts are gold-plated to avoid risk of corrosion. The SD500- PS/PSDA has been tested by UL for compliance to the requirements of the Americans with Disabilities ACT (ADA). Features UL Listed CSFM listed ADA compliant Key reset (Same key as Silent Knight enclosures) Surface mount back box available Terminals - accept up to 14 gauge wire Corrosion-resistant gold-plated contacts. Reflective label rakes it easier to locate in low light Operation The S0500-PS/PSDA single action pull stations are operated by a pull on the front pull cover of the station. A plunger switch, wired to a self contained addressable module, is released as the pull station opens to initiate the alarm. Once operated, the cover hangs down and can be seen up to 100 feet away. The pull station is reset by returning the front cover to the normal upright position and relocking the station with a reset key; The reset keys are the same keys used on Silent Knight enclosures. The SD500-PS/PSDA includes a status LED which blinks, indicating that the addressable module is communicating with the loop. The status LED lights continuously during an alarm. A dip switch on the addressable module is used to set the unique address. Specifications Operating Voltage: 2VDC Standby Current: .55mA Alarm Current: .55mA SD500-PS Ambient Temperature: 32F to 120F (OCto49C) Mounting: Single gang box-• Optional Red Surface Mount Box PS-SMBB 91U MIT KNIGHT , Gang Electrical Box Surface Mount Box SD500-PSDA I,+n;.i.s eranni w Wiring 2.1,? SD500-PS and SD500-PSDA Addressable Pull-Station S Engineering Specifications Manual pull station shall be addressable Module SD500-PS/SD500-PSDA. Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and be made of. a reflective material embossed text 318 inches tail. Operating instruction shall be clearly visible on the same label. Manual station Shall contain 'a key operated test and reset lock using a lock plate actuator, the key shall match the control panel. Manual station shall contain four terminal blocks with two connected to the addressable module and two connect to the SLC loop. Manual station shalt provide data to the control panel with an ID address programmed by dip switch settings. Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. gI.d,II D.magáti IlIUIIII Dimensions D, SILENT - KNIGHT A 7550 Meridian Clrcle,.Maple Grove,.MN. 55369r4927 . . MADE IN AMERICA 800446-6444 or in Minnesota 763493-6435 FORM# 350342, Rev. 09/03 FAX: 763-493-6475 World Wide Web: http://www.silentknlght.com COPfFIht © 2003 Silent Knight [11 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0559:136 Page 1 of I CATEGORY: Boxes/Pull Stations LISTEE: Silent Knight Security, 7550 Meridian Circle',Maple Grove, MN 55369 Contact: *Michael Mc Isaac (763) 493-6400 FAX (763) 391-5464 DESIGN: Model PS-SKSA and SD500-PS fire alarm pull boxes. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm pull station use with separately listed compatible fire alarm control units. For indoor use only. S. Rev. 06-13-2006 This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 6, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division 40 INTELLIKNIGHT ACCESSORY S SD500-AIM & SD-500-MIM Addressable Input Modules lntelliKnight's addressable contact monitor modules combine fast response with pinpoint location ID. A combination that saves lives and property. The SD500-AIM and SD500-MIM are addressable input modules for use with Silent Knight lntelllKnight fire alarm control panels (FACP). The SD500-AIM and SD500-MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500-AIM addressable input module mounts to a 4"-square box. The SD500-MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500-AIM and SD500-MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation—a flexible solution for all your fire protection needs. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800-446-6444, or In Minnesota, call 763-493-6435. S Description The SD500-AIM and SD500-MIM are addressable Input modules for use with the lntelliknight fire alarm control panels (FACPs). The SD500-AIM addressable Input module mounts to a 4"-square box. The SD500-MIM mini input module fits inside a single gang box. Both input modules are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. These modules are supervised, single input contact monitors. Using an EOL resistor, they monitor for alarm contact closures and for open circuit wiring fault conditions. If a fault occurs In the wiring, the module alerts the FACP. Each addressable input module is programmed with a unique signal line circuit (SLC) loop address. Features Single contact monitor Up to 2500 ft wiring distance from either input module to contact Use up to 14 gauge wire UL listed Electrical Specifications Standby Current: 0.55 mA Alarm Current: 23 mA max for one device; 46 mA max for two devices; 0.55 mA for each additional device Line Resistance: 50 max Mechanical Specifications SD500-AIM Physical Description Dimensions: 4.9"W x 4.9" H x 1', 0 (12.4Wx 12.4 H x 2.5 D cm) Weight: 3.6 02 (120.1 g) Color Ivory cover plate SD500-MIM Physical Description Dimensions: 1.5"Wx2.5Hx0.7"D (3.8 W x 6.4 H x 1.8 D cm) Weight: 1.6 oz (45.4 g) SD500-AIM SD500-MIM Approvals NFPA71 & NFPA72 UL 864 CSFM 7300-0559:132 MEA429-92-E Vol. IX FM Approved for use with the 5820XL Support for Class A (Style 6 & Style Environmental 7) or Class B (Style 4) wiring Operating Temperature: Attractive ivory cover plate with the 32°F - 120°F (0°C - 49°C) SD500-AIM Small and lightweight size allows for flexible mounting options with the Humidity: 10% - 93% non-condensing SD500-MIM DIP switch programmable for fast installation SILENT ( KNIGHT by Honeywell SD500-AIM & SD500-MIM Addressable Input Modules Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500-AIM or SD500-MIM. The modules shall be UL listed and compatible with Silent Knights lntelliKnight FACPs. The SD500-MIM shall fit inside a single gang electrical box. The SD500-AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4"-square or double gang electrical box. The SD500-AIM addressable input module must provide a monitor LED that is visible from outside the cover plate S S Compatibility Ordering Information lntelliKnight 5820 FACP S0500-AIM Input Module lntelliKnight 5808 FACP Addressable Input module with ivory lntelliKnight 5700 FACP cover plate. SD500-MIM Mini Input Module Addressable mini input module. D SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are FORM# 350231 Rev.C, 05/06 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 553694927. Copyiight© 2006 Silent Knight Phone: (800) 328-0103, Fax: (763) 493-6475. 0 Model SD500-ARM Addressable Relay Module Place relay applications anywhere on the lntelliknight loop with the SD500-ARM Addressable Relay Module. The SD500-ARM is an addressable device that adds great flexibility to the lntelliKnight system. Providing two Form C contacts rated at 2.0 amps © 30 VDC or .6 amp @ 120 VAC. The SD500-ARM allows you to control a wide variety of normally open and normally closed applications, including elevator recall, door closing, fan operation, and-auxiliary notification. And, because the relay-module is addressable, these applications can be located at any point in the signaling line circuit. Like other lntelliKnight SLC devices, the SD500-ARM is compact for adaptability and pleasing aesthetics. Combine this with the features you've come-to expect from Silent Knight fire protection devices—easy installation and stable operation—and it adds up to a flexible solution for all your fire protection needs. Model SD500-ARM Features Addressable Relay Module W • Two sets of Form C contacts. C The SD500-ARM provides two Form C contacts rated at 2A © 30 VDC or.6A© 120 VAC. These contacts can be used for virtually any normally open or normally closed application. Operation Each relay module is programmed with a unique SLC loop address. When an event that controls the relay module occurs, the relay is triggered by the lntelliKnight panel. Contacts are rated at 2A © 30 VDC or .6A@ 120 VAC. Up to 127 relays can be used on each SLC loop. Relay programming is completely flexible—can be mapped to zone conditions. Polling LED visible Ihrough cover plate. UL listed, complies with NFPA 72. CSFM approved MEA Approved, 429-92-E, Vol. 9 FM approved DSILENT KNIGHT Model SD500-ARM Spedfiflons Contact Rating: Form C 2A @30 VDC .6A@ 120 VAC Standby Current: 55 mA Alarm Current: .55 mA Ambient 32°F to 120°F Temperature (0°C to 49°C) Mounting 4-square electrical box Model SDSOO'.ARM Addressable Relay Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable relay modules, Silent Knight SD500-ARM. The modules shall be UL listed compatible with Silent Knight's lntelliknight FACPs. The relay module must. provide two. Form. C dry contacts rated at. 2.0 amps at 30 VDC or .6 amp at 120 VAC. The relay module must be suitable for mounting in a standard 4-square electrical box and must include a plastic cover plate. The relay module board must provide an LED that is visible from the outside of- the cover, plate. The relay must, be fully programmable. for such applications as. are required, b the installation. FRONT VIEW S CAUTION REMOVE POWER PRIOP TO SERV04G '4 4-7/8" 1" D Model 05004RM Addressable Relay Module Dimensions . SILENT KNIGHT e 7550 Meridian Circle, Maple Grove, MN 55369-4927 MADE IN AMERICA 800446-6444 or in Minnesota 763-493-6435 FORM# 350218, Rev. 11/01 FAX: 763-493-6475 0 World Wide Web: http:/Iwww.sdentknight.com Copyright © 2001 Silent Knight CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE is LISTING No. 7300-0559:132 Page 'l of I CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: Michael Mc Isaac (763) 493-6400 FAX (763) 391-5464 DESIGN: Models SD500-FRCM, SD500-FRCM-4 Monitor Modules and Model SD505-ARM Relay Module. Models SD500-ARM, SD500-AIM, SDSOO-MIM Addressable Input Modules. Models SD500-FRCM and SD500-FRCM-4 monitor modules provide inputs for a control unit communication circuit and one Style B (Class B) contact closure initiating device circuits. Models SD505-ARM and SD500-ARM provide inputs for a control unit communication circuit and have two sets of dry relay contacts. Models SD500-AIM and -MIM provide additional input circuits. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: SD500-FRCM, -FRCM-4, -ARM, -AIM, -MIM: 24 VDC SD505-ARM: 120 VAC, 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7300-0410:145 'Rev. 06-13-2006 This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 61 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering DWision 0 I - Model SD500-ARM "..,. .1. r Addressable Relay Module ( /4 ' Place relay applications anywhere on the -- lntelliknight loop with the SD500-ARM / ;• ' Addressable Relay Module. L.. The S0500-ARM is an addressable device that adds great flexibility to the lntelliKnight system. Providing two Form C.contacts rated at 2.0 amps @ 30 VDC or .6 amp @ 120 VAC. The SD500-ARM allows you to control a wide variety of normally open and normally closed applications, including elevator recall, door closing, fan operation, and auxiliary notification. And, because the relay module is addressable, these applications can be located at any point in the signaling line circuit. Like other lntelliKnight SLC devices, the SD500-ARM is compact for adaptability and pleasing aesthetics. Combine this with the features you've come to expect from Silent Knight fire protection devices—easy installation and stable operation—and it adds up to a flexible solution for all your fire protection needs. Model SD500-ARM Features Addressable Relay Module The SD500-ARM provides two Form C contacts rated at 2A 30 VDC or .6A @ 120 VAC. These contacts can be used for virtually any normally open or normally closed application. Operation Each relay module is programmed with a unique SLC loop address. When an event that controls the relay module occurs, the relay is triggered by the lntelliKnight panel. Two sets of Form C contacts. Contacts are rated at 2A © 30 VDC or.6A@ 120 VAC. Up to 127 relays can be used on each SLC loop. Relay programming is completely flexible—can be mapped to zone conditions. Polling LED visible through cover plate. UL listed, complies with NFPA 72. CSFM approved MEA Approved, 429-92-E, Vol. 9 FM approved Model SD500-ARM Spdftcaffo Contact Rating Form C 2A @ 30 VDC 6A@ 120 VAC Standby Current: .55 mA Alarm Current: .55 mA Amb:ent 32°F to 120°F Temperature (0°c to 49°C) SILENT Mounting 4-square electrical box KNIGHT INTELLIKNRHT ACCESSORY S S Model 0500-ARM Addressable Relay Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable relay modules, Silent Knight SD500-ARM. The modules shall be UL listed compatible with Silent Knight's lntelliknight FACPs. The relay module must provide two Form C dry contacts rated at 2.0 amps at 30 VDC or .6 amp at 120 VAC. The relay module must be suitable for mounting in a standard 4-square electrical box and must include a plastic cover plate. The relay module board must provide an LED that is visible from the outside of the cover plate. The relay must be fully programmable for such applications as are required by the installation. FRONT VIEW .00 0 SRENT IcI9rr 4-7/8" Model SDSOIJ-ARM Addressable Relay Module Dimensions DSILENT KNIGHT z 0 7550 Meridian Circle. Maple Grove. MN 55369-4927 800-446-6444 or in Minnesota 763-493-6435 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com MADE IN AMERICA FORM# 350218. Rev. 11/01 Copyrigt't © 2001 Silen Knight CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 7300-0559:132 Page 1 of I CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: Michael Mc Isaac (763) 493-6400 FAX (763) 391-5464 DESIGN: Models SD500-FRCM, SD500-FRCM-4 Monitor Modules and Model SD505-ARM Relay Module. Models SD500-ARM, SD500-AIM, SD500-MIM Addressable Input Modules. Models SD500-FRCM and SD500-FRCM-4 monitor modules provide inputs fora control unit communication circuit and one Style B (Class B) contact closure initiating device circuits. Models SD505-ARM and SD500-ARM provide inputs for a control unit communication circuit and have two sets of dry relay contacts. Models SD500-AIM and -MlM provide additional input circuits. Refer to Iistée's data sheet for additional detailed product description and operational considerations. RATING: SD500-FRCM, -FRCM-4, -ARM, -AIM, -MIM: 24 VDC SD505-ARM: 120 VAC, 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7300-0410:145 Rev. 06-13-2006 This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or 4* recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 6, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division SERIES AS COOPER Notification S Series AS Audible Strobe Appliances and Series AH Audibles SERIES AH Description The Wheelock patented 2-wire Series AS Audible Strobe Appliances and Series AH Audibles offer more features with low current draw. Strobe options for wall mount models include 1575cd or the Wheelock patented MCWmulti-candela wall strobes with field selectable candela settings of 15130175/110cd, or the high intensity MCWH strobe with field selectable 1351185cd. Ceiling mount models incorporate Wheelock's patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. S The audible provides a selectable choice of either a continuous horn or temporal pattern (Code 3) when constant voltage from a Fire Alarm Panel (FACP) Is applied. Each tone has 3 dBA settings to choose from. When used with the Wheelock Series SMDSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol, synchronization of the continuous horn tone provides the temporal (code 3) tone (mandated by NFPA 72) simultaneously for all audible appliances. This ensures a distinct temporal (code 3) pattern when 2 or more audibles are within hearing distance. If not synchronized the temporal sound could overlap and not be distinctive. At the same time the strobes will be synchronized. This provides the ability to comply with ADA guidelines concerning photosensitive epilepsy and the NFPA standards when installing 2 or more visual appliances within the field of view all of this plus the ability to silence the audible is achieved by using only 2 wire. Features Approvals include: UL Standard 1971 UL Standard 464 New York City (MEA), California State Fire Marshal (CSFM). Factory Mutual (FM), and Chicago (BFP). See approvals by model in Specifications and Ordering Information ADAINFPNUFC/ANSI Compliant Wall mount models are available with Field Selectable Candela Settings of 151301751110cd or 135/185cd (Multi- Candela models) or 1575cd (single ôandela model) Ceiling mount models are available with field selectable candela settings of 15/30/75/95cd or 11 5/1 77cd (multi-candela ceiling models) Selectable Continuous Horn or Temporal (Code 3). 3 Selectable dBA settings (99, 95 and 90 dBA) in both tones Patented 2-Wire Audible Strobe Appliance. Patented Universal Mounting Plate Weatherproof models are available for outdoor use Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VDC models with wide UL "Regulated Voltage Range" using filtered DC or unfiltered FWR input voltage Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol Fast installation with IN/OUT screw terminals using #12 to #I8AWG wires For Weatherproof Series AS, See Detasheet S9004 iEA APPROVU) W E5946 151.92-E 7125.0785:131 55391 NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING. SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND!OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: S Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range'. Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of I to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120F (0C to 49°C) and maximum humidity of 93% (± 2%). Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Ratings Per UL 1971 Model Number Input Voltage VDC Regulated Voltage Range VDCIFWR Strobe Candela (Cd) AS-24MCW 24 16.0-33.0 15/30/75/110 AS-24MCCH 24 16.0-33.0 115/177 AS-241575W 24 16.0-33.0 15 (75 on Axis) AS-121575W 12 8.0-17.5 15 (75 on Axis) AS-24MCC 24 16.0-33.0 15/30/75/95 AS-24MCWH 24 16.0-33.0 135/185 ASWP-2475W 24 16.0-33.0 75 @ -31°F Table 2: dBA Ratings for 12 VDC and 24 VDC Series AS/ AH 12 and 24 VDC Audible Reverberant Anechoic Description Volume dBA Per UL 464 dBA @10 ft. @10 ft. High 91 99 Continuous Medium 88 95 Horn Low 83 90 High 87 99 Code 3 Horn Medium 84 95 Low 79 90 Table 3: Average RMS Current 24 VDC Models Audible Wall Mount Audible Strobe Models Ceiling Mount Audible Strobe Models AH-24 AS-241675W AS-24MCW AS.24MCWH AS-24MCC AS-24MCCH 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 1l5cd 177cd High (99) 24 vdc 0.062 0.100 0.080 0.102 0.150 0.194 0.250 0.320 0.088 0.114 0.165 0.205 0.250 0.320 dBA UL max* 0.080 0.121 0.088 0.125 0.200 0.267 0.355 0.480 0.095 0.138 0.221 0.285 0.355 0.480 Mod (95) 24 vdc 0.033 0.080 0.060 0.084 0.132 0.173 0.230 0.305 0.066 0.092 0.145 0.186 0.230 0.305 dBA ULmax* 0.043 0.107 0.074 0.110 0.190 0.253 0.340 0.465 0.080 0.122 0.201 0.269 0.340 0.465 Low (90) 24 vdc 0.017 0.072 0.052 0.076 0.121 0.158 0.220 0.295 0.056 0.082 0.132 0.173 0.220 0.295 dBA UL max* 0.021 0.100 0.068 0.105 0.182 0.245 0.335 0.460 0.074 0.113 0.198 0.263 0.335 0.460 12 VDC Models Audible Wall Mount Audible Strobe AH-12 AS-121575W * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS currentwithin the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24vunits). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. 12 vdc 0.163 0.260 ru dBALmax' 0.192 0.320 Mod (95) 12 vdc 0.076 0.195 dBA UL max* 0.108 0.275 12 vdc 0.039 0.175 UL max* 0.058 0.265 dBA Table 4:Average Currenr (AMPS) For Series ASWP1 Voltage Setting Setting Setti High dBA Medium dBA Low dBA (99) dBA (95) dBA (90) dBA ng High (99) 24.0 VDC 0.128 0.105 0.098 UL Max 0.168 0.155 0.150 ASO OUTrUI53 EOLRD FO I I 1-40 4 -CL.ASSD AOl I 5.0 OIW CD I I oI I SERIES AS APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES ASO Sari.. SERIES AS APPLIANCES SYNCHRONIZED WITH DSM MODULE CLASS'A NAC CIRCUIT WITH NO AUDIBLE SILENCE FEATURE DSM Interconnecting wiring shown. Msxirnurn twenty (20)0 For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring informationon the power supplies refer to Installation Instructions P84662 for PS-24-81VIC. S Wring Diagrams C SERIES AS APPLIANCES NON-SYNCHRONIZED FROMO +0T0 NEXTO APPLIANCED O OR FACPD R EOLRO PRECEDINGIJ —PPLIANCEO SERIES AS & RSS APPLIANCES SYNCHRONIZED WITH PS-12124-8CP and PS-12/24-8MP FO +OSTRrEM -OSTROBED A StrubrO CiECULtc AS *djb eQ PD EOLRQ AudiblaD -db .0 NACO CircuitO SERIES AS APPLIANCES SYNCHRONIZED WITH SM MODULE SIN- GLE CLASS °B" NAC CIRCUIT WITH AUDIBLESIL.ENCE FEATURE Specifications and Ordering Information Model Number r Order Code Strobe Candela M 0fl Sync DSM or PS-24-81VIC Sync w ISM, 24 12 W II Mount Ceili Mount C ng e MountingOptions*** AgencyApprovals - UL - MEA - CFM - FM - JBFP IS-24MCW-FR 9024 15/30/75/110 X X X - X - A,8,D,EFG,H,J,N.0,R,X X X X X1 X S-24MCW-FW 9025 15/30/751110 X X X - X - A.B,D.E.F,G.H,J,N.O,R,X X )( X X X S-24MCWH-FR 3468 1 135/185 X X X - X - A,B,D,E,F,G,H,J,N.O,R,X X X X X S-24MCWH-FW 3469 135/185 X X X - X - A,B,D,E.F.G,H,J,N,O,R.X X X X X Jx AS-241575W-FR 7405115 (75 on Axis) X X X - X - A,B.D,E,F,G,H,J.N,O,R,X X X X X AS-121575W-FR 7410115 (75 on Axis) X X - X X - A,B,D,E.F,G.H,J.N.O,R.X X X X X X S-24MCC-FR 3161 15/30/75/95 X X X - - X A,B,D,E,F.G,H.J,N,O,R,X X X X X S-24MCC-FW 3162 15130/75/95 X X X - - X A,BD,E.F,GH,JN,OR,X X X X X S-24MCCH-FW 3467 1151177 X X X - - X AB,D,E.F,G,H,J,N,O.R,X X X X X SWP-2475W-FR 9012 75 @ -31 T X X X - X - I(see Data Sheet S9004) X X X X X H-24-R 7892 - X X X - X X A,B,D.E,F,G,H,J,N,O,R,X X X X X X tH-24-W 7893 - X X X - X X A.B,DE,FG,H,J,N,O,R,X X X X X X H-1 2-R 7891 - X X - X X X A,B,D.E,F,G,H,J,N,O,R.X X X, X X X H-1 2-W 7894 - X X - X X X A,B,D,E.F,G,H,J,N,O.R,X X X X X X H-24WP-R 7416 - X X X - X X K X X X X lH-12WP-R 7415 - X X - X X X K X X X X "For Weatherproof Series AS!AH specifications see data sheet S9004. TENDING "Refer to Data Sheet S7000 for Mounting Options. Note: Models are available in either Red or White. Contact Customer Service for Order Code and Delivery. is NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice In accordance with Wheelock Inc. standard terms and conditions. S8100 ASIAH 10107 Wheelock MEN—Cl Architects and Engineers Specifications The notification appliances shall be Wheelock Series AS Audible Strobe appliances and Series AH Audible appliances or approved equals. The SeriesAS Audible be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series AH Audible shall be UL Listed under Standard 464 (Fire Protective Signaling). Both shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). The audible portion of the appliance shall have a minimum of three (3) field selectable sethngs for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series AS shall be of low current design. Where Multi- Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30175/110 or 135/185 candela for wall mount and 15/30/75/95 or 115/177 candela for ceiling mount The selector switch for selecting the candela shall be temper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate. (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash-rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization. The Series AS Audible Strobe and Series AH Audible shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single-gang, double-gang, 4-inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM . LISTING SERVICE LISTING No. 7125-0785:131 Page 1 of 2 CATEGORY: Fire Alarm Devices for the Hearing-Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Deborah Piserchia (732) 433-6001 Fax (732) 222-5607 DESIGN: Models AS-1215, -2415, -1230, -2430, -121575, -241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -W are for wall mount only. Models AS-121575W and AS-241575W lens color may be white, red, blue, green, or amber. Models AS-2415C, -2430C, -2475C and -24100C audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-I2WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. Lens color may be white, red, blue, green, or amber. Models ASWP-2475W and ASWP-2475C audible/strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Lens color may be white, red, blue, green, and amber. Both models are suitable for outdoor use when mounted on the Model WPBB back box. Models AS-24MCWH, AS-24MCCH, eASWP24MCWH, and *ASWP..24MCCH audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. Units with suffix CH are for ceiling mount only. Units with suffix WH are for wall mount only. *Lens color may be white, red, blue, green, or amber. Refer to the listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 8-17.5/16-33 VDCNFWR Flash Rate: 60 flashes/minute Candela: 15:15cd, 1575:15/75cd, 30:30cd, 75:75cd, 95:95cd, 100:100cd, 110:110cd MCW: Selectable 15cd, 30cd, 75cd, 110cd MCC: Selectable 15cd, 30cd, 75cd, 95cd MCWH: Selectable 135cd, 185cd (65cd, 90cd at -40 C) MCCH: Selectable 115cd, 177cd (50cd, 75cd at -40 C) 0 S Listing No. 7125-0785:131 Page 2 of 2 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W, ASWP- 24MCWH, AS-24MCW and AS-24MCWH are for wall mount only. Models ASWP-2475C, ASWP-24MCCH, AS-24MCCH, AND AS-24MCC are for ceiling mount only. Models with suffix - W or WH are for wall mount only. Models with suffix —C or -CH are for ceiling mount only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-12WP, AH-24WP, AswP..2475w ASWP-2475C, ASWP-24MCWH, and ASWP-24MCCH audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12124, SMX-12124, DSM-12124 or DSMX-12/24 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's Installation Instruction Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Models AH-12, AH-24, -I2WP and -24WP audible devices are not suitable for the hearing impaired applications. Rev. 10-01-07 This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 26, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division COOPER Notification Series RSS and RSSP Strobes and Strobe Plates , 4 I E Series RSS Series RSS Series RSSWP RSS Round Description The Wheelock patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current draw while maintaining outstanding performance, reliability and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. Strobe options for wall mount models include 1575 or the Wheelock Patented MCW multi-candela strobe with field selectable candela settings of 15/30175/110cd or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models include the patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. All models may be synchronized using the Wheelock SM, OSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA 72. The Wheelock Series RSS Strobes employ a Patented Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, 100mm European backboxes or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification Appliance Tnmplate) may be used. It provides an additional .65" of trim for the Appliance. An attractive cover plate is provided for a clean, finished appearance on all models. The Series RSSP Multi-Candela Strobe Plates are a cost effective way to retrofit required wall strobe appliances to bells, horns, chimes, multitones or speakers and easily mounts to standard 4" backboxes or for surface mount use with the Wheelock SBL2 surface backbox. . iwiEA 1-1, APPROVED S5391 151-92-E 7125.0785:141 7300-0785:154 S Features Approvals include: UL Standard 1971, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP) See approvals by model in Specifications and Ordering Information ADA/NFPAIUFC/ANSI compliant. Meets OSHA 29 Part 1910.165 Wall mount Multi-Candela models are available with Field Selectable Candela Settings of 15/30/ 751110cd or 135/185cd. Single Candela models are available in 1575cd Ceiling mount Multi-Candela models are available with field selectable candela settings of 15/30/75/95cd or 115/177cd. (Round or Square) Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VDC models with wide UL "Regulated Voltage" us- ing filtered (DC) or unfiltered VRMS input voltage Synchronize using the Wheelock sync moduIeor panels with built-in Wheelock Patented Sync Protocol Fast installation with IN/OUT screw terminals using #12 to #18 AWG wire For Weafhe,pmof Series RSS See Datatsheel S9004 NOTE: All CAUTIONS and WARNINGS are identified by the symbol a. All warnings are printed in bold capital letters. WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND!OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU ANDIOR OTHERS. General Notes: .Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range'. Note that NFPA-72 specifies a flash rate of I to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32F to 120F (0°C to 49'C) and maximum humidity of 93% (± 2%). Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Average RMS Currenr RSSIRSSP -Wall Mount Ceiling Mount RSSIRSSP 241575W 24MCW 24MCWH 24MCC 24MCCH Models 1575cd 15cd I 30cd I 75cd I 11.0cd 135cd I 185cd 15cd I 30cd I 75cd 95cd 115cd I 177cd UL max* 0.090 0.060 10.092 10.166 10.220 10.300 10.420 10.065 10.105 10.189 10.249 1 0.300 1 0.420 RSSIRSSP SSIRSSP Wail Mount 24VDC ____________ * RMS current ratings are per UL average RMS method. UL max current Models 121575W rating isthe maximum RMS currentwithin the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum 12 vdc 0.152 listed voltage (1 6v for 24v units). For audibles the max current is usually at UL max* the maximum listed voltage (33v for 24v units). For unfiltered RNR ratings, 0.255 see installation instructions. =able2-dlbleslSpeakers for RSSP Strobe Plate Uct Series Multitone Appliances AMT, MT Horns AH NH, HS Motor Bells MB-G6/G10 Speakers ET-1010/1080, E70, ET70 Chimes CH70 Wiring Diagrams SERIES RSSIRSSP APPLIANCE FROM + + TO NEXT PRECEDING APPLIANCE - APPLIANCE, SYNC OR EOLR MODULE, POWER - SUPPLY OR FACP SERIES RSSIRSSP APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS "A" NAC CIRCUIT DSM STROBE • NAC SYNC CIRCUIT oui 0.oirrt . IN I RSS RSS RSS eu5I LL 0+.AUDIBLE [IROBE IeNUS2 IN 2 fJ 2 NAC CIRCUIT REtURN ft SERIES RSSIRSSP APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES DSM #1 sync Strobe NAC Cir. RSS RSS F OSM #2 A Strobe NAC Cir. Nflc J[yn Sy~ S% DSM #3 L p Strobe NAC Cir. SynC RSS RSS DSM Interconnecting wiring shown. Maximum of twenty (20) S TROBEIPLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE IN UNISON TO NEXT FROM ____ _____________ + APPLIANCE PRECEDING II II - OR EOLR APPLIANCE, SYNC MODULE, POWER SUPPLY OR FACP + STROBE AUDIBLE STROBEIPLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE INDEPENDENTLY ROId + + TO text M' RJNcEoa - APPLIANCE OREK + - +TONEXT I'RECWIIIO = STROBE OR StROBE. SYUC - - — —EOLR YODULL POWER 51pp1,o,Fscp II II STROBE APPLIANCE 'For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. Forwiring information on the power supplies refer PS-24-8MC. SERIES RSSIRSSP APPLIANCE SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT SM FTR0BE Strobe -fØ - STROBE A NACI 0 C Circuit I Audiblo lJEOLR SERIES RSS!RSSP APPLIANCES SYNCHRONIZED WITH PS-12124-8CP or PS-12/24-8MP Seres PS-12124-EMP OUTPUTS EOLR F 1-4 - 4-CLASS A OR AS RSS C 2-CLASS P II AS RSS Series PS-121244MP Specifications and Ordering Information Model Order Code Wall Mount Ceiling Mount Non- Sync Strobe Candela 24 VDC 12 VDC Color RED Color WHITE Mounting Options Square or Round Agency Approvals - UL MEA CSFM FM BFP RSS-24MCW-FR 940 X X 15/30/75/110 X - X - B,D,E,F,G.H,J,N,O.R.X Square X X X X X RSS-24MCW-FW 9401 X - X 15/30/75/110 X - - X B.D,E,F,G,H,J,N.O,R,X Square X X X X X RSS-241575W-FR 7471 X • X 15(750nAxis) X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-241575W-FW 7788 X - X 15(75onAxis) X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-121575W-FR 7476 X - X 15(75onAxis) - X X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-121575W-FW 7468 X - X 15(75onAxis) - X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-24MCC-FW 3158 - X X 15/30/75/95 X - - X B,D.E.F,G,H,J,N,O,R,X Square X X X X - RSS-24MCC-FR 3157 - X X 15/30/75/95 X I - X - B,D,E,F,G,H,J.N,O,R,X Square X X X X RSS-24MCCR-FW .3160 X X 15/30/75/95 X - - X B,D,E,F.G.H,J,N,O,R,X Round X X X X RSS-24MCCH-FW 3461 - X X 115/177 X - - X B.D,E,F,G,H.J.N.O,R,X Square X X I X X RSS-24MCCHR-FW 3463 - X X 115/177 X - - X B,D,E,F.G,H,J.N.O,R,X Round X X X X RSS-24MCWH-FR 3465 X X 135/185 X X B,D,E,F.G,H,J,N,O,R.X Square X X X X RSS-24MCWH-FW 3464 X X 135/185 X X B,D,E.F.G,H,J,N,O,R,X Square X X X X RSSWP-2475W.FR" 9013 X - X 180@ 77-F X X X - B,D.E.F.G.H.J.N.O.R,X Square X X X X RSSWP-2475W-FW" 3034 X - X 77-F X180@ X - X B,D,E,FG,H.J,N.O.R,X Square X X X X RSSP-121575W-FR 7798 X - X 15(75onAxis) - X X - D.E.Z Square X X X X X - RSSP-24MCW-FR 9402 X - X 15/30/75/110 X - X - D,E,Z Square X X X X X RSSP-241575W-FR 7793 X - X 15 (75onAxis) - - X - D,E,Z Square X X X X X *PENDING All models sync with Wheelock SM, DSM or PS-i 2/24-BCP or PS-i 2/24-aMP. . tModels are available in either Red or White. Call Customer Service for Order Code & Delivery. For Weatherproof Series RSS Strobe specifications see data sheet S9004. "Refer to data sheet S7000 for mounting options. S0410 RSSIRSSP 02108 Notification Wheelock' (MEDC) Architects and Enqineers Specifications The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. The Series RSS Strobe shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30(75/1Ood or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation: If the sync module or Power Supply fails to operate, (i.e. contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single- gang, double-gang, 4-inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The Series R SSP Multi-Candela or single candela Strobe Plate shall mountto either a standard 4 inch square backbox for flush mounting. or the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. NOTE Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock, Inc. standard terms and conditions. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:141 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Deborah Piserchia (732) 433-6001 Fax (732) 222-5607 DESIGN: Synchronized or non-synchronized Strobe Lights. Models are as follows: RSS-##W RSSP-##W RSS-##C RSSP-##C RSS-##CR RSSP4CR 2415 2415 2415 2415 2415 2415 2475 2475 2430 2430 2430 2430 241575 241575 2475 2475 2475 2475 2430 2430 *2495 2495 *2495 *2495 24110 24110 1215 1215 121575 121575 Also, Models RSS-24MCW and RSSP-24MCW, RSS-24MCC, RSS-24MCCR, RSSP- 24MCC, RSS-24MCWH, RSS-24MCWHR, RSSP-24MCWH, RSS-24MCCH, RSS- 24MCCHR, RSSP-24MCCH, ZRS-MCC, *ZRSMCW, *ZRSMCCH and *ZRS.MCWH Model numbers may be followed by any two alpha/numeric character indicating lens orientation, lettering and color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical 12= 8-17.5VDC/FWR OR 24 =16-33VDC/FWR Candela 155cd, 1575=15/75cd on axis, 30=30cd, 75=75cd, 110110cd (Wall) RSS-24MCW, RSSP-24MCW, *ZRS..MCW: Selectable 15cd, 30cd, 75cd orllOcd RSS-24MCC, RSS-24MCCR, RSSP-24MCC, *ZRS..MCC: Selectable S l5cd,30cd,75cd and 95cd RSS-24MCWH, RSS-24MCWHR, RSSP-24MCWH, *ZRS..MCWLd: Selectable 135cd, 185cd RSS-24MCCH, RSS-24MCCHR, RSSP-24MCCH, *ZRS..MCCH: Selectable 115cd, 177cd Flash rate 60 flashes/minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models with suffix -W, wall mount only. Models with suffix -C, ceiling mount only. All models are for indoor use only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL . Listed as strobe light suitable for the hearing impaired when used with separately listed electrically compatible fire alarm control units. For synchronization strobes, Models SM- 12/24, SMX-12124, DSM-12/24 or DSMX-12/24 Sync Control Module (CSFM Listing No. 7300-0785:132) must be used. Refer to listee's Installation Instruction Manual for details. Rev. 12-13-2006jw This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staffhas reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 30, 2008 Listing Expires June 30, 2009 Authorized 'By: BEN HO, Chief • Fire Engineering Division COOP Notification S Weatherproof Appliances - Series AH Audibles, AS Audible Strobes, MT Multitone Strobes, RSS Strobes and ET70 Speaker Strobes and Weatherproof Mounting Accessories Description: Designed for life safety, performance and reliability, Cooper All models may be synchronized using the Wheelock SM, DSM Wheelock's cost effective weatherpoof notification appliances Sync Modules, Wheelock Power Supplies or other manufacturers include: panels incorporating the Wheelock Patented Sync Protocol. The Weatherproof Appliances Series horn output of horn strobes can be independently controlled on 2-wire circuits using the Wheelock patented sync protocol. MTWP Strobes RSSWP horn strobe models are 4-wire appliances; the strobes can be Horn Strobes ASWP synchronized while the audible can be connected to a coded tire Horns AH24Wp, AH12WP alarm system or can be set to produce any of eight selectable Multitone Horn Strobes MTWP tones. Multitone Horns MT Speaker Strobes ET70WP Speakers ET-1010 Features: All strobe models are UL dual listed - meeting both UL1638 and UL1971 requirements. As dual listed appliances, these weatherproof strobes, horn strobes and speaker strobes are listed for outdoor applications under UL 1638 as well as under UL 1971, the Standard for Safety Signaling Devices for Hearing Impaired. With an extended temperature range of —31°F to 150°F (-40°C to 66°C), Wheelock weatherproof appliances meet or exceed UL outdoor test requirements for rain, humidity and corrosion resistance while providing multiple strobe intensity options, including the highest strobe ratings available for area coverage per NFPA 72 strobe spacing tables (up to 185 candela for wall mounting and 177 candela for ceiling mounting). To enable weatherproof mounting, Cooper-Wheelock provides the industry's widest choice of mounting options for surface or unique semi-flush installation. Models are available for surface mounting to Wheelock weatherproof backboxes on walls or ceilings. The optional WP-KIT allows the weatherproof backboxes (LOB, WPBB or WPSBB) to be mounted to a recessed electrical box for concealed conduit installation. For semi-flush installation, the WPA and WFPA kits allow a customer to mount the weatherproof appliances to a recessed electrical box without the need for an external weatherproof backbox. See the Backboxes, Plates and Gaskets Table on page three of this document for a summarization of these mounting options and the required accessories. MEA °'i APPROVED . s.syib isi.q- 7125-0785I31 ASWPI St,391 7125-0786.146 ,ET70WP1 S52 7125-0785 156 jM11NPp 7300-0785.154 1RSSWP1 S Approvals include: UL Standards 1971, 1638, 464 and 1480 California State Fire Marshal (CS FM) and New York City (MEA), Factory Mutual (FM) and Chicago (BFP). See agency approvals by model number on page two of this document Compliance with the following requirements: NFPA. UFC, ANSI 117. 1, OSHA Part 29, 1910.165, ADA Weatherproof with extended temperature range of —40°F to 150°F (-40°C to 66'C)° Dual Listed strobe models (UL 1638 and UL 1971) Industry's highest strobe candela options Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol Models with field selectable tone, dBA and candela settings Wall or ceiling mounting options Surface of semi-flush mounting INfOUT wiring termination accepting two #12-18 AWG wires at each terminal 'The series RSSWP, ASWP. MTWP and ET70WP have UL approval down to -40°F. The AH-24WP, MT-12124 and the ET-1010 have been ULC tested and approved to 40°F. but not submitted to UL. The AH-12WP has ULRJLC approval to -31F. ANMT ET-1010 CT-lab Audible Order Code AH-24WP-R Red 7416 AH-12WP-R Red 7415 Horn MT-12124-R Red 5023 Speaker ET-1010-R Red 3135 ET-1010-W White 3137 UL Max. Current AH 24 VDC 12VDC High(99)dBA 0.080 Med()_dBA . 0.043 _0.192 Low (90) dBA 0.021 _0.108 0.058 IUL Reverberant d8A @ 10 Feet attS11j1/4 1/2i2 4 8 T-1010 77 80 83 86 87 92 94 [ET70WP _78 _81 84 87 90 93 95] NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCtC.COM OR CONTACT COOPER WHEELOCIC FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their UL Listed Regulated Voltage Range. All candela ratings represent minimum effective Strobe intensity based on UL Standards 1971 and 1638 as indicated in candela ratings table. Wall Mount Ceiling Mount Wall or Ceiling Mount I r~t RSSWP MTWP RSSWP MTWP ASWP ET7OWP ASWP ET7OWP Strobe Order Code Strobe Order Code RSSWP-2475W-FR Red 9013 . RSSWP..2475C-FR Red 4338 RSSWP-2475W-FW White 3034 . RSSWP-2475C-FW White 4446 RSSWP-24MCWH-FR Red 5161 RSSWP-24MCCH-FR Red 5167 RSSWP-24MCWH-FW White 5165 RSS WP-24MCCH-FW White 5187 Audible Strobe Audible Strobe ASWP-2475W-FR Red 9012 ASWP-2475C-FR Red 4251 ASWP-24MCHH-FR Red 5137 ASWP-2475C-FW White 4502 ASWP-24MCWH-FW White 5140 ASWP-24MCCH-FR• Red 5149 Multi-tone Strobe . ASWP-24MCCH-FW White 5157 MTWP-2475W-FR Red 8420 Multi-tone Strobe MTWP-2475W-FW White 3112 MTWP-2475C-FR Red 4457 MTWP-24MCWH-FR Red 5132 MTWP-2475C-FW White 4478 MTWP-24MCWH-FW White 5134 MTWP-24MCCH-FR Red 5102 Speaker Strobe MTWP-24MCCH-FW White 5122 ET70WP-2475W-FR Red 9077 Speaker Strobe O 70WP-2475W-FW White 3179 ET70WP-2475C-FR Red 4452 70WP-24185W-FR Red 4885 ET70WP-2475C-FW White 4454 T -T7OWP-24185W-FW White 4891 ET70WP-24177C-FR Red 4845 ET70WP-24135W-FR Red 4872 ET70WP-24177C-FW White 4859 ET70WP-24135W-FW White 4875 ET70WP-2411 5C-FR Red 4550 _______________ ET70WP-24115C-FW White 4732 Candela Ratings Series UL 1971 UL 1636 UL 1638 RSS, ET70WP and MTWP UL Max Current ASWP High Med Low @ 77-F @ -40-F - LS.!!obe Only) 2475 30" 180 115 0.1.38. 0.168 0.155 0.150 - MCWH 135 185 135 185 56 77 --- 0.300 0.420 0.355 0.480 0.340 0.465 0.335 0.460 MCCH 177 115 ___115 115 .- 177 47 -- 73 0.300---. ------- 0.420 [ 0.355 0.340 0.335 0.480 0.465 0.460 24185 185 185 77 0.420 "Wall mount rating only 24177 1177 177 - 73 0.4201 JL Max. Current MTWP/MT MT AudibIo) iBA 24 VDC HI STD 12 VDC -- HI STO iiiiiT j0108 0044 0177 0034 Beli 0.053 0.024 0.095 0.020 March Time 0.104 0.038 0.142 0.034 ode 3Horn 0.091 0.035 0.142 0.034 Code 3 Tone 0075 0035 0i05 0.021 Slow Whoop 0.098 0.037 0.142 0.035 Siren 0.104 0.036 0.152 0.030 Lo O.O57D25l0M4 Model Number Strobe Agency Approvals JULIMEAM BFP RSSWP-2475 - X X X RSSWP-24MCWH X J * X RSSWP-24MCCH xj x * AudibleStrobe ASWP-2475 ASWP-MCWH X X X • X X X X ASWP-MCCH X * X * * Multilane Strobe IMTWP-2475 X X X X 'MTWP-MCWH MTWP-MCCH X X * X X * Horns/Audibles X X X - X X AH-24WP AH-12WP . MT-12/24 X X X X I X Speaker Strobe IjT70WP-2475 IET70WP115 pa X X L X . L Pending Mounting Accessories WFP WFPA lOB WPSBB WPBB WBB (,k.t Kit flrilnr C.nrtp WP-KIT 4486 MountingOptions: Backboxes, Plates, Gasket Kits Flush Plates WFPA-R Red 4698 I- ----- ---------.-- Surface Mount J Flush WFPAW White - - - Exposed Conduit Concealed Conduit Mount WFP-R Red 4696 - WFP-W White 4697 RSSWP Strobes .WPSBB WPSBB+WP-KIT WFP Backboxes ET70WP Speaker Strobes lOB lOB + WP-KIT WFP IOB-R IOBW Red White 5046 5047 ASWP Horn Strobes ---- WF`88 -_-__ WF`B8 + WP-KIT - WFPA WPSBB-R Red 9751 AHWP Horns WBB - WFP WPSBB-W White 3033 ET-1010 Speakers WBB - WFP WPBB-R Red 9014 ------------- - --- -- WPBB-W White 4692 MTWP Multilane Horn Strobes lOB lOB + WP-KIT WFP WBB-R Red 2959 Multilane Horn lOB lOB + WP-KIT WFP WBB-W White 2960 -.----.-----.----- ---------- r I F +E TO NEXTL CEDINGJ L:] I APPLIANCE. IANcE FACPU --OR EOLRI I A+U Z4-1 .,TP)8'1 '.JDIR:. ?L. SERIES RSSWP, ASWP, AHWP, MTWP AND MT-12/24 APPLIANCES FROM -1 TO NEXT PRECEDTNG _-l.7 ppLTANcEr APPLIANCE ORIJ OR EOLR 1 FACP I I SERIES MTWP APPLIANCES SYNCHRONIZED STROBE OPERATION WITH CODED FACP :.,rwp 0 0 0 Synjfi t.Lrtu1 MdUJ ./) NM: •I'I —I-(2J ,,.rt PorIi FACPJ Supply U.S.0 I ' Note; Strobe circuit requires constant voltage. SERIES RSSWP!ASWP APPLIANCES SYNCHRONIZED WI DSM MODULE SINGLE CLASS "A" NAC CIRCUIT D SMI sTPcaF.LJ MCI S?NC - CIRCUIT - I I OUTJ (7I±.4i? I _______ :- SPHE fl NAC CIRCUIT-1 RETURN- Wiring Diagrams SERIES MTWP AUDIBLE APPLIANCE AND STROBE OPERATE IN UNISON. RED AND BLACK SHUNT-WIRES ARE SUPPLIED. I Note: Models are available in Red or White. Contact Customer Service for Order Code and Delivery. #Refer to Data Sheet S7000 for Mounting Options NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelck Inc. standard terms and conditions. ARCHITECTS AND ENGINEERS SPECIFICATIONS General Weatherproof notification appliances shall be UL listed for outdoor use. Weatherproof Strobe appliances shall be listed under UL Standard 1638 (Standard for Visual Signaling Appliances) for Indoor/Outdoor use and UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired). The appliances shall be available for optional wall mounting or ceiling mounting to weatherproof backboxesusing either oxposod conduit or concealed conduit, or semi-flush mounting to a recessed electrical box in walls or ceilings using Wheelock mounting accessories. Weatherproof Strobes Weatherproof Strobe appliances shall produce a minimum flash rate of 60 flashes per minute over the UL Regulated Voltage Range of 16 to 33 VDC and shall incorporate a Xenon flashtube. The weatherproof strobes shall be available with UL 1971 candela ratings up to 185 cd for wall mounting and 177 cd for ceiling mounting. UL 1638 candela ratings up to 180 cd at 77°F shall be available. The strobes shall operate over an extended temperature range of —40°F to 150°F (-40°C to 66°C) and be listed for maximum humidity of 95% RH. Strobe inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). - Weatherproof Audibles and Audible/Strobe Combinations Weatherproof horns and multitone audibles shall be listed for Indoor/Outdoor use under UL Standard 464. The horns shall be able to produce a continuous output or a temporal code-3 output that can be synchronized. The horns shall have at least 3 sound level settings. Horn/Strobe combinations shall be able to be synchronized on a single NAC. Multitone audibles shall be able to produce 8 distinct tones selectable by dip switch and shall have at least 2 sound level settings. Multitone Audible/Strobe combinations shall have independent inputs for the audible and strobe. The strobes shall be able to be synchronized. The audibles shall be able to be coded when operated on a separate NAC. Weatherproof Speakers and Speaker/Strobes Weatherproof speakers and speaker/strobes shall be listed for Indoor/Outdoor use under UL Standard 1480. All speakers shall provide field selectable taps for 1/8W to 8W operation for either 25 VRMS or 70 VRMS audio systems and shall incorporate a sealed back construction for extra protection and improved audibility. Speakers without strobes shall be Wheelock Series ET-1010. They shall be listed to produce up to 94 dBA and shall incorporate a vandal resistant grille design. Speaker with strobes shall be Wheelock Series ET70WP. They shall be available for surface or semi-flush mounting to walls or ceilings and shall be listed to produce up to 93 dBA. Synchronization Modules When synchronization of strobes or temporal code-3 audibles is required, the appliances shall be compatible with the Wheelock Series SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes and audibles shall not drift out of synchronization at any time during operation. Series ASWP audibles and strobes shall be able to be synchronized on a 2-wire circuit with the ability to silence the audible if required. The strobes on Series MT multitone audible/strobe appliances shall be able to be synchronized and shall be able to be operated on a separate circuit from the audibles while the audible circuit is connected to a coded or continuous NAC. Weatherproof Mounting Accessories Weatherproof mounting options shall include surface mounting or semi-flush mounting to walls or ceilings. Surface mounted appliances hall mount to Wheelock 1013. WBB, WPBB or WPSBB weatherproof backboxes using either exposed conduit or concealed conduit. or concealed conduit the weatherproof backbox shall be mounted to a recessed electrical box with Wheelock's WP-KIT to provide a weatherproof seal for the electrical box. Semi-flush mounted appliances shall mount to a recessed electrical box using Wheelock WFP or WFPA flush plates to provide a weatherproof seal between the electrical box and the appliance. TErg4 U IiuII•L1 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY AAnda in I IRA S9004 WP fl5/OR SooPer Notification is Wheelock' (c) SAFEPATH COOPER Notification CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION GFFICF OF THF STATF FIRF MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0785:154 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Luy Nguyen (732) 433-6005 Fax (732) 222-5607 DESIGN: Models RSSWP-2475W synchronous or non-synchronous strobe light. Model may be followed by two alpha or numeric characters indicating lettering and color, followed by W for wall mount Refer to listee's data sheet for additional detailed product description and operational considerations. RATING:. Electrical: 16-33 VDC Flash rate: 60 flashes/mm. Candela: 75 Cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Model can be used outdoors when used with WPSBB back box only. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a strobe light for use With separately listed electrically compatible fire alarm control units. For indoor or outdoor use. Intended for wall mount only. For synchronized strobes, Models SM-12/24, SMX-12/24 Sync Modules, DSM-12124 or DSMX-12/24 Duel Sync Modules (CSFM Listing No. 7300-0785:1323) or power supply PS- 12/24-8 (CSFM Listing No. 7315-0785:149) must be used. NOTE: Not suitable for hearing impaired application. Rev. 06-13.06 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy. State Fire Marshal Program Manager