2180 RUTHERFORD RD; ; FA090035; Permit
11/10/2020 FA090035 Permit Data City of Carlsbad Fire Alarm- Permit Permit No: FA090035 2180 RUTHERFORD JobAddress: Status: ISSUED RD Permit Type: FALARM Applied 7/9/2009 Parcel No: 2120702500 Approved: 7/22/2009 Lot #: 0 Reference No.: Issued: 7/22/2009 PC #: Inspector: Project Title: CALLAWAY HQ PHASE 3 OT FIRE ALARM CHECK & TWO INSPECTIONS Applicant: Owner: CALLAWAY GOLF CO 2180 RUTHERFORD RD CARLSBAD. CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 300 0 300 0 1/1 FA oloo'35 CALLAWAY GOLF PHASE 3 2180 RUTHERFORD RD. CARLSBAD, CA 92008 Fire Alarm Submittal 07/08/09 i. (0, Submitted By; N VA SERITY 10744 Rockvill Street SUITE 104 Santee, CA. 92071 619-460-7414 Cont. Lic. C-10 # 802053 FILE Copy CALLAWAY GOLF PHASE 3 Fire Alarm Submittal Eguiiment List _Qty Description Model Manufacture CSFM# 1 Fire Alarm Panel (EXIST.) 5820XL SILENT KNIGHT 7170-0559:135 8 Fire Alarm input module SDSOO-AIM SILENT KNIGHT 7300-0559:132 4 Fire Alarm Power Supply95 5495 SILENT KNIGHT 7170-0559:123 41 Horn/Strobe Clg Mnt multi-cd AS-24MCC WHEELOCK 7125-0785:131 4 Horn/Strobe Wall Mnt multi-cd AS-24MCW WHEELOCK 7125-0785:131 Is. 38 Strobe Clg Mnt multi-cd RSS-24MCC WHEELOCK 7125-785:141 8 Connection to existing Duct Detectors Lot Wire 18/2Cond. (Initiation) Lot Wire 14/2 Cond. (Notification) Lot Wire 18/4Cond. (Annunciator) Lot Wire 2 #14 THWN (Underground) lntelliKnight® Model 5820XL Addressable Fire Alarm Control System The lntelliKnight System is the easy way to make the most of fire alarm technology. lntelliKnight 5820XL is the first fire alarm system to provide you with revolutionary value and performance in addressable sensing technology. The 5820XL FACP offers exclusive, built-in digital communication, distributed intelligent power, a modular design and an expanded, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the 5820XL system, or to locate your nearest source, please call 1-800-446-6444, or in Minnesota, call 763-493-6435. Description Improvements in SKSS software 5820XL performs drift compensation deliver five times faster uploads/downloads and calibration checks on each of the r sensors in the system. Two built-in Form C programmable i The basic 5820XL system can be relays rated at 2.5 amps at 27.4 VDC. t•. expanded by adding modules such as Supports sounder bases 5860 remote annunciator, 5815XL - 6 amp power supply and maximum i signalling line circuit expander, 5824 charging capacity of 35 amp hours f" -1• serial/parallel printer interface module (An additional cabinet enclosure is (for printing system reports) and required for batteries in excess of 18 , iI 5895XL intelligent power module amp hours) 5820XL also features a powerful built-in Programmable date setting for dual line fire communicator that allows Daylight Saving Time if. - for reporting of all system activity to a Plex-1 door option combines a dead remote monitQnng location front cabinet door with a clear window, limiting access to the panel c- • Featur while providing single button Up t 508 a ressable points operation of the reset and silence functions ..................: f Uses ta ard wire—no shielded or - twiste air required Electrical Specifications •c 1. Built-in digital communicator Primary AC: S Central station reporting by point or 120 VRMS at 50/60 Hz, 2.5A or by zone Built-in synchronization for appliances from AMSECO, Gentex®, Faraday, System Sensor, and Wheelock® Flexput 110 circuits Supports Class B (Style 4) and Class A (Style 6) configuration for SLC, SBUS, and Flexput circuits Distributed, intelligent power Drift compensation 13 pre-programmed output cadences (including ANSI-3.41) and 4 programmable outputs Built-in annunciator with 80-character LCD display RS-485 bus provides communication to system accessories Built-in RS-232 and USB interface for programming via PC Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC 240 VRMS at 50/60 Hz, 1.4A Total Accessory Load: 6A @ 27.4 VDC, power-limited Standby Current: 215 mA Alarm Current: 385 mA Flexput Circuits: Six programmable circuits which can be programmed individually as: Notification circuits: 3A @ 27.4 VDC per circuit, power-limited Auxiliary power circuits: 3A @ 27.4 VDC per circuit, power-limited Initiation Circuits: 100 mA @ 27A VDC per circuit, power limited Mechanical Specifications Flush Mount Dimensions: 14.5W x 24.75H x 3.9"D (36.8 W x 62.9 H x 9.8 D cm) model 552UAL Overall Dimensions: 16.2W x 26.4"H x 4.2"D (40.6W x 67 H x 11.8 D cm) Weight: 28 lbs. (12.8 kg) Color: Red Battery Charging Capacity: 7.0-35 AH Battery Size: 18 AH max allowed in control panel cabinet. Larger capacity batteries can be housed in RBB accessory cabinet. Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack; RJ3I X (two required) S1LNT JKNIGIfl WHO lntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Indicator Lights General Alarm (Red): Flashes when in alarm; solid when alarm silenced Supervisory (Yellow): Flashes when a supervisory condition exists; solid when supervisory silenced System Troubles (Yellow): Flashes when a trouble condition exists; solid when trouble silenced System Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared System Power (Green): Flashes for AC failure; solid when power systems are normal Addressable photoelectric smoke detector Addressable ionization smoke detector Addressable heat sensor Addressable duct smoke detector Contact module Relay output module Addressable notification module The following advanced sensor capabilities are available with 5820XL: Automatic drift compensation Maintenance alert Built-in sensor test to comply with NFPA72 calibration testing requirements 5820XL features a 6 amp power supply and maximum battery charging capacity of 35 amp hours. An additional Flexput circuits on 5820XL control can be individually programmed to function as notification circuits, auxiliary power outputs, or initiation circuits that support both 2- and 4-wire smoke detectors. The 5820XL system operates on non- twisted, unshielded cable when wired in compliance with standard wiring practices as called out in the National Electric Code 760-51. Specifications for power-limited fire protective signalling cables. No Special wiring is required. 5820XL provides 13 preset notification cadence patterns (including ANSI 3.41) and four user programmable selections for fire alarm notification. Two programmable general purpose Form C relay outputs are provided on 5820XL. Additionally, the lntelliKnight system features a built-in walk test and auto- programming. Its innovative, dead-front cabinet design allows for flush or surface mounting. System maintenance is easy to perform. User Interface The 5820XL built-in annunciator with 80 character LCD display and large easy-to-use tactile touchpad can be used for system operation, programming and maintenance. It has five LEDs for alarm, supervisory, system trouble, system silenced and system power. System operations include silencing alarms and troubles, resetting alarms and the display of alarm troubles and memory. The system's non-volatile event history buffer stores 1000 events for viewing from the built-in or remote annunciator. System operation can be initiated with a mechanical firefighter's key or a valid 4- to 7-digit operator's code. Programming The IntelliKnight system offers several options to simplify and speed up programming. The JumpStart® feature minimizes programming required to start a new system. The built-in keypad and 5860 remote annunciator give on-site access to all programming. You can also program remotely using the 5660 Silent Knight Software Suite, which is Windowsk based software. Built-In Digital Communicator 5820XL features a built-in UL listed digital communicator for remote reporting of system activity and system programming. The communicator has the ability to seize two telephone lines to report alarms and troubles to a monitoring facility. The communicator supervises two phone lines and will activate a trouble signal if a line failure is sustained for more than 45 seconds. Other communication features include: retry if communication fails, two phone number capability, download phone number capability and Touch-Tone or rotary dialing. The communicator is compatible with SIA and Ademco Contact ID. The format is selectable by account number. Approvals NFPA 13, NFPA 15, NFPA 16, NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; .& Water Deluge Releasing Service. Suitable for automatic, manual, waterfiow, sprinkler supervisory (DACT non-coded) signalling services. Other Approvals: UL Listed; CSFM 7170-0559:135; MEA 429-92-E Vol. VI; FM Approved System Application 5820XL has one built-in signalling line •circuit (SLC) which supports 127 devices. Three additional loops can be added using the 5815XL SLC e pan rtç increase overall capacity t"08 deviths. The 5820XL SLC loops support multiple device types, including: .cabinet enclosure (PN RBB) is required for batteries in excess of 18 amp hours. IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel ................. . . .. ( S2OXL L. 586 çL. 581511. 815XL OR . .. . k() ' c3up - > :) . . 1?A • ..__.;,; .- . f ].. 1 1• ., 1.. - - •• 'SO SOS.APS D505.AIS S0505.GSB SD5O5.AHS. S0500.SOt.1 -. . . .• - . : iq I L__ • . h tDr. (1. SD5l)TS '-c-- SD5flO-LC-D S)5OO;ANM SDSOS-6R13 8D505-61B SDSOS.GAB Sabo p M . i 1. .L... u. ., I I tLwl U 4 . I . 1 . 4 •- / -. I aii' :S-5O-ADHR USOO.PS SDSUS.AOH SUSDU41I r,0 SUGOO.A . so0-um. . •C1ott . •..: . . .. • uoC.tc. I' . . . •.,- . 58E5.4or5BG,-3 1 , •1 ;s Zcth•4 • . . iiieiiikfl1ght512OXL Addressa ble. Fire Atàrrn óntroIPanè1 and Compatihic Devicos INTELLIKNIGHT FIRE ALARM CONTROL PANEL SLC Detectors SCModu)e 5820XL devices feature a low profile SD500AlM design and EEprom addressing. Drç contact input odule for use with .EEprom addressing prevents water normally op ry contacts. It features intrusion problems via the back of the or LED to show alarm status. sensor and eliminates mechanical failures related to decade switches. SD505-APS Addressable photoelectric smoke detector. SD505-AlS Addressable ionization smoke detector. SD505-AHS Absolute temperature heat detector that goes into alarm immediately if the temperature exceeds the programmable trip point. Trip point range from 135°F-150°F(0°C--37°C). SD505-GAB Six inch base for use with detector heads SD505-APS, SD505-AIS, and SD505-AHS. S0505-4AB Four inch base for use with detector heads SD505-APS, SD505-AlS, and SD505-AHS. S0505-BSB Six-inch sounder base for use with existing sensor and base. Operates in single and multi-station modes and/or as a system sounder. Requires 2 additional wires for power. SD505-61B Six-inch isolator base for use with existing base and the SD505-APS, SD505-AlS, and SD505-AHS sensors. Provides isolation for style 7 circuits. SD505-SRB Six-inch relay base for use with existing sensor and base. Provides one Form C contact. SD505-ADH Duct housing that detects smoke in HVAC ducts. S0505-ADHR Duct detector base with relay. Provides Form C alarm contact. For use with SD505-APS and 5D505-AIS sensors. Compatible with SD505-DTS remote test switch. S0500-PSIS0500-PSDA SD500-PS is a single action pull station and SD500-PSDA is a dual action pull station. SD500-MIM Mini dry contact input module is a small version of the SD500-AIM. For use with pull stations and other normally open dry contact inputs. SD500-ANM Addressable notification module providing a single Class A or Class B notification circuit on the SLC. SD500-ARM Addressable relay module. Features 2 Form C output relays. Provides indicator LED to show output status. S0500-SDM Two-wire detector input module. Allows for the connection of conventional 2-wire detectors on the SLC loop. Requires two additional wires for power. SD500-LIM A short circuit isolator module for SLC devices. When a short occurs on the SLC loop, it is detected as a trouble, but all SLC devices protected by the isolator module continue to operate. SD500-LED An LED driver module capable of driving 80 LEDs. Use up to 40 modules per SLC loop and up to 100 SD500-LED modules per system. S-BUS Accessories 58601111 Remote Fire Annunciator Features the same 80 character backlit LCD display keypad and firefighter's keyswitch as the 5820XL. 5860 is gray and 586CR is red. 5815XL Signal Line Circuit Expander The SLC expander is used to add more addressable devices to the lntelliKnight sys . supports three 15XLs. Each 5 I5XL can support 27 devices. 5895XL Intelligent Power Module Adds 6 amps of power, 6 Flexput I/O circuits and 2 Form C relay circuits to a 5820XL system. 5496 Intelligent Power Module A 6 amp notification power expander that provides tour power-limited notIt- 5880 LEDIIO Module Features 40 LED outputs, 8 normally :en dry contact and iezo L 5865-3 and 5865-4 Remote LED Annunciator Features 30 programmable LED (15 red and 15 yellow) outputs, and a piezo sounder. The 58654 adds a silence and reset switch to the package. 5883 Relay Board Features 10 general purpose Form C relays. Used with 5880 module. 5824 Serial/Parallel Printer Interface Module Provides one parallel and one RS-232 serial port for connecting a printer to the 5820XL. Use to print a real-time log of system events, detector status reports, and event history. Interfaces with building control system. Miscellaneous Accessories 5660 Silent Knight Software Suite (SKSS) User-friendly Windows software for remote programming of 5820XLs using a PC. Upload and view panel account information, event history, and detector status. 5670 Silent Knight Software Suite (SKSS) Powerful end-user facility management software allows viewing of detector status and event history via modem or direct connection. Plex-1 Dead front cabinet door with clear Window to limit access to the FACP. RBB Remote battery box accessory cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16Wx10"Hx6"D (406 mm W x 254 mm H x 152 mm D) S0505-DTS Remote test switch. Used with SD505-ADHR. Provides remote key operated test function and annunciation of detector alarm. cation appliance circuit outputs. D SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350210 Rev E. 04/06 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, MN 553694927. Copyright © 2006 Silent Knight Phone: (800) 328-0103, Fax: (763) 493-6475. lntelliKnight & JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF TM STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISFING PROGRAM LISTING SERVICE OISTING No. 7170-0559:135 Page 1 of 2 CATEGORY: Control Unit (High-Rise) LISTEE: Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: Michael Mclsaac (763) 493-6400 FAX (763) 391-5464 DESIGN: Models 5820, *5820xL *lFp..1 000 Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterfiow, water releasing and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: C 5820, 5820XL, IFP-1000 *058200P 5815/5815XL 7628 lntelliknight 5820 5860/5860R/RA-1000 5496 5824 5895/5895XL/RPS-1 000 5865-3/5965-4 5880 5883 SDSOO-ANM SD500-LIM 5D505-61B SD-500 SDM RA-100 3158 5220 *122365 *AB33 *5897 *5898 *058601 Control Units Motherboard Analog Loop Expander EOL Resistor Enclosure Annunciator Power Module Serial/Parallel Interface Power Expander/Supply LED Annunciator LED 10 Module Relay Interface Board Addressable Notification Module Line Isolation Module Isolation Base Smoke Detector Module Remote Reverse Polarity Module Direct Connect Module Enclosure Battery Cabinet Power Supplies User Interface C.' RATING 120 VAC Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. 0 Rev. 08-17-2006 jw Listing No. 7170-0559:135 Page 2 of 2 APPROVAL: Listed as control units for.use in high-rise structures when used in conjunction with Model SKE-360 Voice-Tone Evacuation Unit (CSFM Listing No. 6912-0559:122); EVAX Audio Adjunct System Models EVAX-25 (CSFM Listing No. 06911-1446:100), EVAX-50 or EVAX- 50E (CSFM Listing No. 06911-1446:102); EVX-2ZA or EVX-4Z Zone Splitters (CSFM Listing No. 06912-1446:101); HMX-MP or HMX-DP Voice Evacuation System (CSFM Listing No. 06911-1446:103), two-way firefighter telephone and separately listed electrically and functionally compatible initiating and indicating devices. Also suitable for non-high-rise applications where the voice evacuation and two-way firefighter telephone are not required. Refer to listee's Installation Instruction Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. S Rev. 08-17-2006 jw A50 . 11 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. 0 Date Issued: Authorized By: FRANCIS MATEO, Program Coordinator Fire Enaineerina Division JUNE 181 2009 Listing Expires June 30, 2010 S13500-AIM Approvals NFPA7I&NFPA72 UL 864 CSFM 7300-0559:132 MEA 429-92-E Vol. IX FM Approved for use with the 5820XL TT1 'SILENT KNIGHT by Honeywell SDSOO-AIM & SD500-MIM Addressable Input Modules IntelIiKnight's addressable contact monitor modules combine fast response with pinpoint location ID. A combination that saves lives and property. The SD500-AIM and SD500-MIM are addressable input modules for use with Silent Knight lntelliKnight lire alarm control panels (FACP). The SD500-AIM and SD500-MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500-AIM addressable input module mounts to a 4°-square box. The SD500-MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500-AIM and SD500-MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation—a flexible solution for all your fire protection needs. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800-446-6444, or in Minnesota, call 763-493-6435. Description DIP switch programmable for fast The SD500-AIM and SD500-MIM are installation input modules for use with Up to 2500 ft wiring distance from .addressable the lntelliknight fire alarm control either input module to contact panels (FACPs). The SD500-AIM Use up to 14 gauge wire addressable input module mounts to a UL listed 4°-square box. The SD500-MIM mini input module fits inside a single gang Electrical Specifications box. Both input modules are designed Standby Current: 0.55 mA to be used with pull stations, water flow Alarm Current: 23 mA max for one switches, and other applications device; 46 mA max for two devices; requiring dry contact alarm initiation 0.55 mA for each additional device devices. These modules are supervised, single Line Resistance: 500 max input contact monitors. Using an EOL Mechanical Specifications resistor, they monitor for alarm contact SD500-AIM Physical Description closures and for open circuit wiring Dimensions: fault conditions. If a fault occurs in the 4.9" W x 4.9" H x 1" D wiring, the module alerts the FACP. (12.4 W x 12.4 H x 2.5 0 cm) Each addressable input module is Weight: 3.6 02 (120.1 g) programmed with a unique signal line Color: Ivory cover plate circuit (SLC) loop address. SD500-MIM Physical Description Features Dimensions: - Single contact monitor 1.5" W X 2.5" H X 0.7" D SDSOO-AIM supports Class A (Style (3.8Wx6.4Hx 1.8Dcm) D) or Class B (Style B) contact Weight: 1.6 02 (45.4 g) monitor wiring Environmental - SD500-MIM support for Class B (Style B) contact monitor wiring Operating Temperature: . • Attractive ivory cover plate with the. 32°F - 120°F (0°C - 49°C) SD500-AIM Humidity: - Small and lightweight size allows for 10% - 93% non-condensing flexible mounting options with the SD500-MIM SD500-AIM & SD500-MIM. Addressable Input Modules Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500-AIM or SD500-MIM. The modules shall be UL listed and compatible with Silent Knight's lntelliKnight FACPs. The SD500-MIM shall fit inside a single gang electncal box. The SD500-AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4"-square or double gang electrical box. The SD500-AIM addressable input module must provide a monitor LED that is visible from outside the cover plate Compatible FACPs 5820XL 5808 5700 Ordering Information SD500-AIM Input Module Addressable input module with ivory cover plate. SD500-MIM Input Module Addressable mini input module. 0z' StLENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are FORM# 350231 Rev D, subject to change without notice. For more information, contact Silent Knight © 2008 Honeywell International Inc y Honsywe 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Phone: (800) 328-0103 or 763-493-6400 Fax: (763) 493-6475. www.silentknight.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECIION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE OISTING No. 7300-0559:132 Page 1 of I 'CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: *Michael Mc Isaac (763) 493-6400 FAX (763) 391-5464 DESIGN: Models SD500-FRCM, 5D500-FRCM-4 Monitor Modules and Model SD505-ARM Relay Module. Models SD500-ARM, SD500-AIM, SD500-MIM Addressable Input Modules. Models SD500-FRCM and SD500-FRCM-4 monitor modules provide inputs for a control unit communication circuit and one Style B (Class B) contact closUre initiating device circuits. Models 5D505-ARM and SD500-ARM provide inputs for a control unit communication circuit and have two sets of dry relay contacts. Models 5D500-AIM and -MIM provide additional input circuits. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: SD500-FRCM, -FRCM-4, -ARM, -AIM, -MIM: 24 VDC S0505-ARM: 120 VAC, 30 VDC NSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XL: 7300-0410:145 *Rev. 06-13-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 189 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division Model 5495 Distributed Power Module In an emergency, you need maximum power. The 5495 Distributed Power Module by Silent Knight is the most powerful' and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sènsor@,Gentex®, AMSECO®, Wheelock and Faraday - what you need to drive power-hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. And, ADA retrofits are easier and 'less expensive -with the 5495 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost-effective notification power supply available, you need the 5495. Call Silent Knight today for more information at 1-800-446-6444. Model 5495 Distributed Power Module The 5495 is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with fire and security controls such as the Silent Knight Model 5208 Fire Control /Communicator. The 5495 is the cost- effective solution for powering notification appliances required by the Americans with Disabilities Act (ADA). The 5495 has built-in ANSI cadence pattern, which can upgrade older control panels that lack cadence capability. Features UL Listed for 6 amps of notification power Power supply's advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems Dip switches allow for easy reconfiguration 24 VDC filtered output voltage Four power-limited notification outputs; 2 Class A or 4 Class B, or I Class A and 2 Class B Additional continuous auxiliary output 3 amps per output circuit 2 inputs; 2 Class B or 2 Class A Ground fault detector/indicator Independent trouble relay AC loss delay option shuts off power to non-essential high-current accessories like magnetic door holders Built-in synchronization for appliances from System Sensore,Gentexe, AMSECO, Wheelock and Faraday Stand alone operation Lightweight design adds to ease of installation and reduces shipping costs Operates with most polarized, UL Listed notification devices UL 864 & 1481 listed CSFM approved ANSI Cadence pattern output capability built-in Connection to Local Fire Control The 5495 may be connected to a local fire control which utilizes Class A or Class B type notification circuits operating between 9 and-32 VDC. The control panel's notification circuit is connected to one of the inputs on the 5495. The control panel's notification circuit end-of-line resistor is also connected across two terminals on the 5495, which provides supervision between the 5495 and the fire control panel. Polarized audible andlor visual notification devices are then connected to the 5495 signal circuits using the X0 4 V. SI.. Model 5495 Distributed Power Module 4.7kQ end-of-line resistors provided. Since the 5495 draws very little power from the control, it is possible to connect one 5495 to each notification circuit on the control panel and still provide full supervision of the notification circuits all the way back to the control panel. DSILENT KNIGHT by Honeywell Model 5495 Distributed Power Module Supervision Current: Input The 5495 supervises a variety of Standby 75 mA voltage range: 9 - 32 VDC functions including: Alarm 175 mA Battery charging Low AC power Auxiliary capacity: 33.0AH Low battery condition power circuit: 1 Ambient temp.: 320 to 120° F Earth ground fault Notification 00 to 490 C Auxiliary output power limit circuits: 4 Mechanical condition Output Dimensions: 12.25" W x 16" H x EOL supervision trouble or configuration: 2 Class A (Style Z) 3" D (30.88 cm W power limited condition at an 4 Class B (Style Y) x 40.64 cm H x output (1 Class A& 7.62 D cm) When a trouble condition occurs, 2 Class B) Indicator Lights the 5495 creates a trouble Amps per AC power on: Green condition on the host control signal circuits to which it is connected. the output circuit: 3.0 (6.0 amps total) Battery trouble: Yellow 5495 still maintains the ability to be Notification Ground fault: Yellow activated by the host control. In circuit output: 20.4 to 27.3 VDC Aux trouble: Yellow addition, the 5495 provides a Form @ 3.0 amps each, C trouble relay output as an 4.7 42 EOL Output alternative to using the notification resistor required troubles (1-4): Yellow circuit trouble. on each Class B Approvals: Electrical Specification circuit UL: 864 & 1481 AC input: 120 VAC at 2 amps No. of inputs 2 72 NFPA: Output: 24 VDC at 6 amps Input 2 Class B or 2 CSFM configuration: Class A Módël 5495 BI Ck DigiTi; Signal CfrcuitÔutput Signal Circuit Output SInáI I Distrtbuted Power Module 5495: Signal 1 Signal 2 _______ Si9nàl Signal 2 -input (OptiOnal) 120 VAC Aux. Power trouble Output Local Fire ContrOl (AIter16tito'notificabn circuittrouble). -- SILEN'r. This document is not intended to be used for installation purposes. We try to MADE IN AMERICA • keep our product information up-to-date and accurate. We cannot cover all' 1KWiGiiT specific applications or anticipate all requirements. All specifications are FORM# 350395 Rev B, 12/05 subject to change without notice. For more information, contact Silent Knight by•Honeweil 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Copyright © 2005 Silent Knight Phone: (800) 328-0103, Fax: (763) 493-6475. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECtION OFFICE OF 'THE STATE FIRE MARSHAL -: FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM -. LISTING SERVICE IRISTING No. 7300-0559:123 Page 1 of I CATEGORY: LISTEE DESIGN RATING INSTALLATION: OARKING: Misc. Devices/Control Unit Accessories Silent Knight Security, 7550 Meridian Circle, Maple Grove MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 FAX (763) 391-5464 Models 5395 5495 a d *5499 Distributed Power Module (Indicating Circuit Expander). Unit is pow -limited a d consists of an enclosure, printed circuit board, terminal boards, end-of-un r sistors nd two I2VDC, 7Ah rechargeable batteries. The unit provides up to 4 indicati g nd I auxiliary output. Refer to listee's data sheet for additional detailed roduct description and operational considerations. Input: 120 VAC, 2A, 60 hz Output: 24 VDC In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Unit must be able to provide 24 hour battery back-up as required per code. Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as indicating circuit expanders for use with separately listed compatible indicating devices and polarized, 24 VDC, fire alarm control unit. Model 5495 and 5499 can generate a distinctive temporal pattern fire alarm signal as required per NFPA 72, 2002 Edition. If required, models 5395 must be use with fire alarm control unit or indicating signaling devices that can produce the temporal code pattern. Refer to listee's Installation Manual for details. Recert 08-17-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or •• recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. / Date Issued: JUNE 18, 2009 Listing Expires June 30, 2010 / S Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division Series AS Audible Strobe Appliances and Series AH Audibles SERIES AH Description The Wheelock patented 2-wire Series AS Audible Strobe Appliances and Series AH Audibles offer more features with low current draw. Strobe options for wall mount models include 1575cd or the Wheelock patented MCW multi-candela wall strobes with field selectable candela settings of 15/30/75/110cd, or the high intensity MCWH strobe with field selectable 135/185cd. I Ceiling mount models incorporate Wheelock's patented MCC multi-candela ceiling strobe with field selectable intensities of 15130/75195cd or the high intensity MCCH strobe with field selectable 115/177cd. The audible provides a selectable choice of either a continuous horn or temporal pattern (Code 3) when constant voltage from a Fire Alarm Panel (FACP) is applied. Each tone has 3 dBA settings to choose from. When used with the Wheelock Series SM,DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol, synchronization of the continuous horn tone provides the temporal (code 3) tone (mandated by NFPA 72) simultaneously for all audible appliances. This ensures a distinct temporal (code 3) pattern when 2 or more audibles are within hearing distance. If not synchronized the temporal sound could overlap and not be distinctive. At the same time the strobes will be synchronized. This provides the ability to comply with ADA guidelines concerning photosensitive epilepsy and the NFPA standards when installing 2 or more visual appliances within the field of view all of this plus the ability to silence the audible is achieved by using only 2 wire. Features Approvals include: UL Standard 1971, UL Standard 464 New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP). See approvals by model in Specifications and Ordering Information ADA/NFPA/UFC/ANSI Compliant Wall mount models are available with Field Selectable Candela Settings of 15130/75/110cd or 1351185cd (Multi- Candela models) or 1575cd (single candela model) Ceiling mount models are available with field selectable candela settings of 15130/75195cd or 115/177cd (multi-candela ceiling models) Selectable Continuous Horn or Temporal (Code 3). 3 Selectable dBA settings (99, 95 and 90 dBA) in both tones Patented 2-Wire Audible Strobe Appliance. Patented Universal Mounting Plate Weatherproof models are available for outdoor use Strobes produce I flash per second over the regulated voltage range 12 and 24 VDC models with wide UL "Regulated Voltage Range" using filtered DC or unfiltered FWR input voltage Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol Fast installation with IN/OUT screw terminals using #12 to #I8AWG wires For Weatherproof Series AS, See Datasheet S9004 0 Wall Mount Audible Audible 12 VDC Models Strobe AH-12 I AS-121575W vdc 0.163 0.260 max' 0.192 0.320 High (99)FI L2dBA Med (95) 12 vdc 0.076 0.195 UL max' 0.108 0.275 dBA (90) 12 vdc 0.039 0.175 _____ UL max' 0.058 0.265 NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION ANDIOR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. rat Notes: trobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range. Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of I to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%). Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). "Regulated Voltage Range" is the newest terminology used by UL to identity the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Ratings Per UL 1971 Model Number Input Voltage VDC Regulated Voltage Range VDCIFWR Strobe Candela (Cd) AS-24MCW 24 16.0-33.0 15/30/75/110 AS-24MCCH 24 16.0-33.0 1151177 AS-241575W 24 16.0-33.0 15 (75 on Axis) AS-121575W 12 8.0-17.5 15 (75 on Axis) AS-24MCC 24 16.0-33.0 15/30/75/95 AS-24MCW1-I 24 16.0-33.0 135/185 ASWP-2475W 24 16.0 -33.0 75 @ -31°F Table 2: dBA Ratings for 12 VDC and 24 VDC Series AS/ AH 12 and 24 VDC Audible Reverberant Description Volume dBA Per UL 464 dBA dBA @10 ft. @10 ft. High 91 99 Continuous Medium 88 95 Horn Low 83 90 High 87 99 Medium 84 95 Code 3 Horn Low 79 90 T 3: Average RMS Current 41 - Audible 11 Moun udible Strobe Models Ceiling Mount Audible Strobe Models 24 VDC Models AH-24 AS-241575W (AS-2rV.)'kk '3 AS-24MCWH MC AS-24MCCH 1575cd 15cd 30cd 75cd 135cd 185cd 1 5cd 30cd 75cd 95cd 115cd 1 77cd High (99) 24 vdc 0.062 0.100 0.080 0.102 0.1601 0j94. 0.320 oii: .0.114. ö"O2O5 0.250 0.320 dBA UL max 0.080 0.121 0.088 0.125 0.200 0.355 0.480 0.095 0.138 0.221 0.285 0.355 0.480 Med (95) 24 vdc 0.033 0.080 0.060 0.084 0.132 0.173 0.230 0.305 0.066 0.092 0.145 0.186 0.230 0.305 dBA UL max* 0.043 0.107 0.074 0.110 0.190 0.253 0.340 0.465 0.080 0.122 0.201 0.269 0.340 0.465 Low (90) 24 vdc 0.017 0.072 0.052 0.076 0.121 0.158 0.220 0.295 0.056 0.082 0.132 0.173 0.220 0.295 dBA UL max* 0.021 0.100 0.068 1 0.105 0.182 0.245 0.335 0.480 0.074 0.113 0.198 0.263 0.335 0.460 Table 4: Average Current' (AMPS) For Series ASWP# Voltage High dBA Setting (99) dBA Medium dBA Setting (95) dBA Low dBA Setting (90) dBA 24.0 VDC 0.128 0.105 0.098 UL Max 0.168 1 0.155 1 0.150 * RMS current ratings are per UL average RMS method. UL max current rating isthe maximum RMS currentwithin the listed voltage range (16-33v for24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Wring Diagrams"' SERIES AS APPLIANCES NON-SYNCHRONIZED FROM!] +T0 NEXTD PRECEDING!] APPLIP,NCED _PPLIANCED OR EOLRD OR FACPD SERIES AS & RSS APPLIANCES SYNCHRONIZED WITH PS-121244CP and PS-12/24-8MP ASO RSSD FO OUTPUrSO ED I i 1-40 I 4-CLASStI AD I I WLRD CD I I 2-CLASSD I -A- PD I I ASO SERIES AS APPLIANCES SYNCHRONIZED WITH DSM MODULE CLASS"A" NAC CIRCUIT WITh NO AUDIBLE SILENCE FEATURE SERIES AS APPLIANCES SYNCHRONIZED WITH SM MODULE SIN- GLE CLASS "B" NAC CIRCUIT WITH AUDIBLESILENCE FEATURE +OSTROB -osTRoaei [I:!: 0__],~ +5udjb eQ EOLRO -n NAcO Circuitfl SERIES AS APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES Audible NAC CSM #10 FD Strobe NAC c?Y % NDK~ OSM #20 AD :::: CD Audible NAC Strobe NAC I Specifications and Ordering Information DSM Interconnecting wiring shown. Maximum twenty (20)0 11 For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring informationon the power supplies refer to Installation Instructions P84662 for PS-24-81VIC. Model Number Order Code Strobe b Candela N Ofl Sync Sync wISM, DSM or PS-24-8MC 24 VDC 12 VDC W a II Mount ei C Mount ung T Mountin Agency Approvals UL MEA CSFM FM BFI S-24MCW-FR 9024 15/30/75/110 X X X - X - A,B,D,E,F,G,H,J,N,O,R,X X X X X X S-24MCW-FW 9025 15/30/75/110 X X X - - A,B,D,E,F,G,H,J,N,O,R,X X X X X X S-24MCWH-FR 3468 135/185 X X X - X - A,B,D,E,F,G,H,J,N,O,R,X X X X X * S-24MCWH-FW 3469 135/185 X X X - - A,B,D.E.F,G,H,J,N,O,R,X X X X X * AS-241575W-FR 7405 15 (75 on Axis) X X X - X - A,B4O,E,F,G,H,J,N,O,R,X X X X X X AS-121575W-FR 7410 15(75onAxis) X X - X X - A,B,D,E,F,G,H,J,N,O,R,X X X X X X DS-24MCC-FR 3161 15/30/75/95 X X X - - X A,B,D,E,F,G,H,J,N,O,R,X X X X X * S-24MCC-FW 3162 15/30175/95 X X X - - X A,B,D,E,F.GH,J,N,O,R,X X X I X X * S-24MCCH-FW 3467 115/177 X X X - - X A,B,D,E,F.G,H,J,N,O,R,X X X X X * SWP-2475W-FR 9012 75 @ -31°F X X X - X - I(see Data Sheet S9004) X X X X X \H-24-R 7892 - X X X - X X A,B,D,E,F,G,H,J,N,O,R,X X X X X X H-24-W 7893 - X I X X - X X A,B.D,E.F.G,H,J,N,O,R.X X X X X X H-12-R 17891 - X X - X X X A,B,D,E,F,G,H,J,N,O,R,X X X I X X X H-12-W 7894 - X X - X X X A,B,D,E,F,G,H,J,N,O,R,X X X X X X I k%H-24WP-R— 7416 - X X X - X X K X X X - X H-12WP-R 7415 - X X - X X X K X X X X *For Weatherproof Series AS/AH specifications see data sheet S9004. *PENDING *** Refer to Data Sheet S7000 for Mounting Options. Note: Models are available in either Red or White. Contact Customer Service for Order Code and Delivery. Architects and Engineers Specifications The notification appliances shall be Wheelock Series AS Audible Strobe appliances and Series AH Audible appliances or approved equals. The SenesAS Audible be listed for UL Standard 1971 (Emergency Devices forthe Hearing-Impaired) for Indoor Fire Protection Service. The Series AH Audible shall be UL Listed under Standard 464 (Fire Protective Signaling). Both shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). audible portion of the appliance shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice ontinuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series AS shall be of low current design. Where Multi- Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110 or 135/185 candela for wall mount and 15/30/75/95 or 115/177 candela for ceiling mount The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash-rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization. The Series AS Audible Strobe and Series AH Audible shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single-gang, double-gang, 4-inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. S WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA S8100 ASIAK 10107 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECIION OFFICE OF ThE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE ISTING No. 7125-0785:131 Page 1 of 2 CATEGORY: Fire Alarm Devices for the Hearing-Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Deborah Piserchia (732) 433-6001 Fax (732) 222-5607 DESIGN: Models AS-1215, -2415, -1230, -2430, -121575, -241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1 215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -Ware for wall mount only. *Models AS-121575W and AS-241575W lens color may be white, red, blue, green, or amber. Models AS-2415C, -2430C, -2475C and -241 OOC audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-I2WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. S Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. *Lens color may be white, red, blue, green, or amber. Models ASWP-2475W and ASWP-2475C audible/strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Lens color may be white, red, blue, green, and amber. Both models are suitable for outdoor use when mounted on the Model WPBB back box. Models AS-24MCWH, AS-24MCCH, *ASWP..24MC and *ASV24MCCH audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. Units with suffix CH are for ceiling mount only. Units with suffix WH are for wall mount only. *Lens color may be white, red, blue, green, or amber. Refer to the listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 8-17.5/16-33 VDCNFWR Flash Rate: 60 flashes/minute Candela: 15:15cd, 1575:15/75cd, 30:30cd, 75:75cd, 95:95cd, 100:100cd, I10:110cd MCW: Selectable I 5cd, 30cd, 75cd, 110cd MCC: Selectable 15cd, 30cd, 75cd, 95cd MCWH: Selectable I 35cd, 185cd (65cd, 90cd at -40 C) MCCH: Selectable 115cd, I77cd (50cd, 75cd at-40 C) Listing No. 7125-0785:131 Page 2 of 2 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W, ASWP- 24MCWH, AS-24MCW and AS-24MCWH are for wall mount only. Models ASWP-2475C, ASWP-24MCCH, AS-24MCCH, AND AS-24MCC are for ceiling mount only. Models with suffix - W or WH are for wall mount only. Models with suffix -c or -CH are for ceiling mount only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-I2WP, AH-24WP, *AsJD..2475w ASWP-2475C, ASWP-24MCWH, and ASWP-24MCCH audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12/24, DSM-12124 or DSMX-12/24 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's Installation Instruction Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. SOTE: Models AH-1 2, AH-24, -I2WP and -24WP audible devices are not suitable for the hearing impaired applications. *Rev. 10-01-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 189 2009 Listing Expires June 30, 2010 Authorized By FRANCIS MATEO, Program Coordinator Fire Engineering Division Series RSS and RSSP Strobes and Strobe Plates ffi Series RSS Series RSS Series RSSWP RSS Round Description The Wheelock patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current draw while maintaining outstanding performance, reliability and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. S Strobe options for wall mount models include 1575 or the Wheelock Patented MCW multi-candela strobe with field selectable candela settings of 15/30175/110cd or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models include the patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. All models may be synchronized using the Wheelock SM, - DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. Synchronized strobes can eliminate possible restrictions on the number of, strobes in the field of view. Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA72. The Wheelock Series RSS Strobes employ a Patented Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, 1 00m European backboxes or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification Appliance Trim plate) may be used. It provides an additional .65" of trim for the Appliance. An attractive cover plate is provided for a clean, finished appearance on all models. The Series RSSP Multi-Candela Strobe Plates are a cost effective way to retrofit required wall strobe appliances to bells, horns, chimes, multitones or speakers and easily mounts to standard 4" backboxes or for surface mount use with the Wheelock SBL2 surface backbox. nUl f1dS ~'Y I , < fi> Features Approvals include: UL Standard 1971, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP) See approvals by model in Specifications and Ordering Information ADNNFPNUFC/ANSI compliant. Meets OSHA 29 Part 1910.165 Wall mount Multi-Candela models are available with Field Selectable Candela Settings of 15/30/75/110cd or 135/185cd. Single Candela models are available in 1575cd Ceiling mount Multi-Candela models are available with field selectable candela settings of 15/30/75/95cd or 1151177cd. (Round or Square) Strobes produce I flash per second over the regulated voltage range 12 and 24 VDC models with wide UL "Regulated Voltage" us- ing filtered (DC) or unfiltered VRMS input voltage Synchronize using the Wheelock sync modules or panels with built-in Wheelock Patented Sync Protocol Fast installation with IN/OUT screw terminals using #12 to #18 AWG wire For Weatherpmof Senes RSS See Datatsheet S9004 NOTE: All CAUTIONS and WARNINGS are identified by the symbol A All warnings are printed in bold capital letters. WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION ANDIOR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. rat Notes: robes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range". Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%). Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Average RMS Current* RSSIRSSP - Wall Mount ei g Mount RSSIRSSP 241575W 24MCW 24MCWH 24MCC 24MCCH 24VDC j Models 1575cd 15cd I 30cd I 75cd I 110cd 135cd I 185cd 15cd 30cd 75cd I 95cd 115cd I 177cd I UL max* I 0.090 I 0.060 10.092 10.165 I 0.220 10.300 10.420 10.065 I 0.105 I 0.189 10.249 I 0.300 I 0.420 I RSSIRSSP RSSIRSSP Wall 24VDC Mount Models ___________ * RMS current ratings are per UL average RMS method. UL max current 121575W rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum 12 vdc 0.152 listed voltage (16v for 24v units). For audibles the max current is usually at UL max* 0.255 the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Now Table 2: AudibleslSpeakers for RSSP Strobe Plate Product Series Multitone Appliances AMT, MT Horns AH, NH, HS Motor Bells MB-G6/G10 Speakers ET-1010/1080, E70, ET70 Chimes CH70 Wiring Diagrams # ISERIES RSSIRSSP APPLIANCE FROM ___ _______ TO NEXT PRECEDING APPLIANCE APPLIANCE, SYNC OR EOLR MODULE, POWER SUPPLY OR FACP H SERIES RSSIRSSP APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS "A" NAC CIRCUIT DSM STROBE NAC SYNC 0 CIRCUIT OUT 1iI I I I I IFACP TROBE MINUS2 NAC CIRCUIT RETURN SERIES RSSIRSSP APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES DSM #1 Stiobe NAC Cir. RSS RSS F DSM #2 A Strobe NAC Cir. )eDSM #3 Strobe NAC Cir. Sync St RSS RSS DSM Interconnecting wiring shown. Maximum of twenty (20) TROBEIPLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE IN UNISON TO NEXT FROM ____ ______ ______ + APPLIANCE PRECEDING t II i II - OR EOLR APPLIANCE, SYNC MODULE, POWER ____ ____ SUPPLY OR FACP LL-I1+-I STROBE AUDIBLE STROBEIPLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE INDEPENDENTLY FROM -I. PRECEDING + TONEXr APPLIANCE OR - APPLIANCE - OR EOLR FACe FROM + TO NEXT PRECEDING STROBE OR STRODESYNC EOLR - MODULE. POWER SUPPLY OMFAcP STROBE APPLIANCE For detail using SM or DSM Sync Module refer to Data Sheet 53000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the power supplies refer PS-24-8MC. SERIES RSSIRSSP APPLIANCE SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT SM F STROBE Strobe A NAC Circuit STROBE :11~~ C t7.—....AudibIe P EOLR Q--AudibIe SERIES RSS!RSSP APPLIANCES SYNCHRONIZED WITH PS-12124-8CP or P5-12124-8MP Series PS-12124-8MP OUTPUTS AS RSS EOLR F - 4-CLASS A .B' :B)~M AS OR RSS C 2-cLASS P RSS Series PS-12124-SMP MI Specifications and Ordering Information Model Order Code Wall Mount Ceiling Mount Non- Sync Strobe Candela 24 VDC 12 VDC Color RED Color WHITE Mounting • °u'1 g p 1 Square Round Agency Approvals — UL MEA CSFM FM BFP RSS-24MCW-FR 940 X - X 15/30/75/110 X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-24MCW-FW 9401 X - X 15/30/75/110 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-241575W-FR 7471 X - X 15(75onAxis) X - X - B,DE,F,G,H,J,N,O,R,X Square I X X X X X RSS-241575W-FW 7788 X - X 15(75onAxis) X - - X B,D,E,F,G,H,J,N,O,R.X Square X X X X X RSS-121575W-FR 7476 X - X 15(75onAxis) - X X - B,D,E,F.G,H,J,N,O,R,X Square X X X X X RSS-121575W-FW 7468 X - X 15(75onAxis) - X - X B,D,E,F,G,H,J.N,O,R,X Square X X X X X RSS-24MCC-FW 3158 - X X 15/30/75/95 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X RSS-24MCC-FR 3157 - X X 15/30/75/95 X - X - B,D,E,F,G,H,JN,O.R,X Square X X X X * RSS-24MCCR-FW 3160 - X X 15/30/75/95 X - - X B,D,E,F,G.H,J,N,O,R,X Round X X X X * RSS-24MCCH-FW 3461 - X X 115/177 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSS-24MCCHR-FW 3463 - X X 115/177 X - - X B.D.E,F,G,H,J,N,O,R,X Round X X X X * RSS-24MCWH-FR 3465 X X 135/185 X X B,D,E.F.G,H,J,N,O,R,X Square X X X X * RSS-24MCWH-FW 3464 X X 135/185 X X B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSSWP2475WFR** 9013 X - X 180@ 77-F X X X - B.D.E,F,G,H,J,N,O,R,X Square X X X X * RSSWP-2475W-FW 3034 X - X 180CD 77-F X X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X RSSP-121575W-FR 7798 X - X 15(75onAxis) - X X - D,E,Z Square X X X X X RSSP-24MCW-FR 9402 X - X 1 15/30/75/110 X - X - D,E,Z Square X X X X X I I1575-F 7793 X - X 115 (75 on Axis) - - X - D,E,Z Square X X X X X PENDING All models sync with Wheelock SM, DSM or PS-1 2/24-BCP or PS-1 2124-8MP. # Models are available in either Red or White. Call Customer Service for Order Code & Delivery. rcnnecrs ana The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon fiashtube enclosed in a rugged Lexan® lens. .Adftnuts shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When We Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. The Series RSS Strobe shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/301751110cd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single- gang, double-gang, 4-inch square, 100mm European type backboxes, orthe SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The Series RSSP Multi-Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox for flush mounting, or the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock, Inc. standard terms and conditions. n WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA S0410 RSSIRSSP 02108 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECFION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LTSTENG PROGRAM -. LISTING SERVICE OISTING No. 7125-0785:141 Page 1 of I CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Deborah Piserchia (732) 433-6001 Fax (732) 222-5607 DESIGN: Synchronized or non-synchronized Strobe Lights. Models are as follows: RSS-W RSSP-W RSS-C RSSP-C RSS-CR RSSP-##CR 2415 2415 2415 2415 2415 2415 2475 2475 2430 2430 2430 2430 241575 241575 2475 2475 2475 2475 2430 2430 *2495 *2495 *2495 *2495 24110 24110 1215 1215 121575 121575 Also, Models RSS-24MCW and RSSP-24MCW, RSS-24MCC, RSS-24MCCR, RSSP- 24MCC, RSS-24MCWH, RSS-24MCWHR, RSSP-24MCWH, RSS-24MCCH, RSS- 24MCCHR, RSSP-24MCCH, *ZRS.MCC *ZRS..MCW *ZRS..MCCH and *ZRS..MC Model numbers may be followed by any two alpha/numeric character indicating lens orientation, lettering and color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical 12 = 8-17.5VDC/FWR OR 24 16-33VDC/FWR Candela 15=5cd, 1575=15/75cd on axis, 30=30cd, 75=75cd, 110=110cd (Wall) RSS-24MCW, RSSP-24MCW, *ZRS..MCW: Selectable 15cd, 30cd, 75cd • or ll0cd RSS-24MCC, RSS-24MCCR, RSSP-24MCC, *ZRS..MCC: Selectable 15cd, 30cd, 75cd and 95cd RSS-24MCWH, RSS-24MCWHR, RSSP-24MCWH, *ZRS..MCJLd: Selectable 135cd, 185cd RSS-24MCCH, RSS-24MCCHR, RSSP-24MCCH, *ZRS..MCCH: Selectable 115cd, 177cd Flash rate 60 flashes/minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models with suffix -W, wall mount only. Models with suffix -C, ceiling mount only. All models are for indoor use only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe light suitable for the hearing impaired when used with separately listed electrically compatible tire alarm control units. For synchronization strobes, Models SM- 12/24, SMX-12/24, DSM-12/24 or DSMX-12/24 Sync Control Module (CSFM Listing No. 7300-0785:132) must be used. Refer to listee's Installation Instruction Manual for details. Rev. 12-13-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. JUNE 18, 2009 Listing Expires June 30, 2010 FRANCIS MATEO, Program Coordinator Date Issued Authorized By: