HomeMy WebLinkAbout2180 RUTHERFORD RD; ; FA120006; Permit11/10/2020 FA1 20006 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FA120006 E;IIJIUHhtrIi1IIi Job Address: Status: PENDING RD Permit Type: FALARM Applied 1/20/2012 Parcel No: 2120702500 Approved: Lot #:0 Reference No.: Issued: PC #: Inspector: Project Title: CALLAWAY GOLF HEADQUARTERS T.I. Applicant: NOVA SECURITY SUITE 103 8779 COTTONWOOD AV SANTEE, CA 619-448-3007 Owner: • CALLAWAY GOLF CO 2180 RUTHERFORD RD CARLSBAD CA Fees ($) Add'I Fees ($) : Total : Balance ($) 233 0. . 233 0 1/1 SILENT KNIGHT lntelliKnight® Model 5820XL Addressable Fire Alarm Control System by Honeywell The lntelliknight System is the easy way to make the most of fire alarm technology. lntelliKnight 5820XL is the first fire alarm system to provide you with revolutionary value and performance in addressable sensing technology. The 5820XL FACP offers exclusive, built-in digital communication, distributed intelligent power, a modular design and an expanded, easy to use interlace. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the 5820XL system, or to locate your nearest source, please call 800-328-0103. Description 5820XL is an intelligent addressable fire alarm control panel (FACP). The F basic 5820XL system can be expanded by adding modules such as 5860 remote annunciator, 5815XL signalling line circuit expander, 5824 serial/parallel printer interface module (for printing system reports), and Isom 5895XL intelligent power module. 5820XL supports Hochiki or SK devices. 5820XL also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features Built in support for 99 SK detectors and 99 SK modules, expandable to 396 SK detectors and 396 SK modules using System Sensor protocol Built in support for 127 Hochiki devices, expandable to 508 Hochiki devices using Hochiki protocol. Uses standard wire—no shielded or twisted pair required Built-in digital communicator Central station reporting by point or by zone Built-in synchronization for appliances from AMSECO®, Gentex®, Faraday, System Sensor, and Wheelock® FlexputTM I/O circuits Supports Class B (Style 4) and Class A (Style 6) configuration for SLC, SBUS, and Flexput circuits Distributed, intelligent power Drift compensation 13 pre-programmed output cadences (including ANSI-3.41) and 4 programmable outputs Built-in annunciator with 80-character LCD display RS-485 bus provides communication to system accessories Built-in RS-232 and USB interlace for programming via PC Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC Improvements in SKSS software deliver five times faster uploads/downloads Two built-in Form C programmable relays rated at 2.5 amps at 27.4 vDC Supports sounder bases 6 amp power supply and maximum charging capacity of 35 amp hours (An additional cabinet enclosure is required for batteries in excess of 18 amp hours) Programmable date setting for Daylight Saving Time Plex-1 door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing single button operation of the reset and silence functions 16) Model 5820XL Installation The 5820XL can be surface or flush mounted Compatibility The 5820XL SLC supports multiple device types of the same protocol: 5K (System Sensor) Hochiki You cannot mix Hochiki and SK devices on a FACP. rf A DJQD(DfO lntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Indicator Lights General Alarm (Red): Flashes when in alarm; solid when alarm silenced Supervisory (Yellow): Flashes when a supervisory condition exists; solid when supervisory silenced System Troubles (Yellow): Flashes when a trouble condition exists; solid when trouble silenced System Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared System Power (Green): Flashes for AC failure; solid when power systems are normal System Application 5820XL has one built-in signalling line circuit (SLC) which supports multiple devices dependent on protocol being used. Three additional loops can be added using the 5815XL SLC expanders to increase overall capacity. The 5820XL SLC loops support multiple device types, including: Addressable photoelectric smoke detector Addressable ionization smoke detector Addressable heat sensor Addressable duct smoke detector Contact module Relay output module Addressable notification module Addressable beam detector (SK protocol only) Addressable multi-criteria smoke detector (5K protocol only) Addressable multi modules (SK protocol only) The following advanced sensor capabilities are available with 5820XL: Automatic drift compensation Maintenance alert Built-in sensor test to comply with NFPA 72 calibration testing requirements 5820XL features a 6 amp power supply and maximum battery charging capacity of 35 amp hours. An additional cabinet enclosure (PN RBB) is required for batteries in excess of 18 amp hours. Flexput circuits on 5820XL control can be individually programmed to function as notification circuits, auxiliary power outputs, or initiation circuits that support both 2- and 4-wire smoke detectors. The 5820XL system operates on non- twisted, unshielded cable when wired in compliance with standard wiring practices as called out in the National Electric Code 760-51 specifications for power-limited fire protective signalling cables. No special wiring is required. 5820XL provides 13 preset notification cadence patterns (including ANSI 3.41) and four user programmable selections for fire alarm notification. Two programmable general purpose Form C relay outputs are provided on 5820XL. Additionally, the lntelliKnight system features a built-in walk test and auto- programming. Its innovative, dead-front cabinet design allows for flush or surface mounting. System maintenance is easy to perform. User Interface The 5820XL built-in annunciator with 80 character LCD display and large easy-to-use tactile touchpad can be used for system operation, programming and maintenance. It has five LEDs for alarm, supervisory, system trouble, system silenced and system power. System operations include silencing alarms and troubles, resetting alarms and the display of alarm troubles and memory. The system's non-volatile event history buffer stores 1000 events for viewing from the built-in or remote annunciator. System operation can be initiated with a mechanical firefighters key or a valid 4- to 7-digit operators code. Programming The InteIliKnight system offers several options to simplify and speed up programming. The JumpStart® feature minimizes programming required to start a new system. The built-in keypad and 5860 remote annunciator give on-site access to all programming. You can also program remotely using the 5660 Silent Knight Software Suite, which is Windows®- based software. Built-In Digital Communicator 5820XL features a built-in UL listed digital communicator for remote reporting of system activity and system programming. The communicator has the ability to seize two telephone lines to report alarms and troubles to a monitoring facility. The communicator supervises two phone lines and will activate a trouble signal if a line failure is sustained for more than 45 seconds. Other communication features include: retry if communication fails, two phone number capability, download phone number capability and Touch-Tone or rotary dialing. The communicator is compatible with SIA and Ademco Contact ID. The format is selectable by account number. Approvals NFPA 13, NFPA 15, NFPA 16, NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterfiow, sprinkler supervisory (DACT non-coded) signalling services. Other Approvals: UL Listed; CSFM 717G-0559:135; MEA 429-92-E Vol. VI; FM Approved bT Receiver -'-- h4 *.iUMEflSt4Wtlt Intcrnct ;!_J sIc-auO Connection VbarAla7ln IP njnciIc S8SSXL IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel InteIIiKnight 5820XL DOW Addressable Fire Alarm System SK (System Sensor) Protocol Devices U1iMC3c 5258 5224 R.mvin,4y flIVSG&ntfl* 110 Circtilo can ca htaut Cu oulpLjtt. U r nF o F?oapu1 110 C.—can be input C. oviput S$-Ien SIcMofliCOr SPC.PhoIo SKCoiilrol B200SR SK-Heat SK.Zon4 MCISS8II Mrtewlft. AO*,natla 041cft€!a3 &ijfttf, aaüflre daCu !CWOdCCu FtWoVam CbeMCu.e om e.e ICu SK.Pliulo-T SK.Contre?.0 8K.Heal.ROR 0224R8 822481 02IOLJ hl4tetntte ft-, hr. .IJeIuUe R,I Casey Den:, .asu Unvaslca, Ise.rase an# a.. ene SKaam 5IC.Men.10 SIç44ea.HT SII.PuII0A SK.,ct SPC.Bcnn..t Miea*Cbe Ala.nelC. autC. y.CCab, ea,,ue MybesC. Car.en IM !iDabe, eDen,, inC DNtD. 9,uldrrec, r ' SK.Minlnion SK-Relay-6 SICuo Denesue Vinia MsLIe bD#. Use the 5880to central UpIo4 .._ 5883 Relay Interface Modu'ea 5283 i!q'nk&fliittós 586540, 5865.3 :4. 5360 lntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Specifications Electrical Primary AC: 120 VRMS at 50/60 Hz, 2.5A or 240 VRMS at 50/60 Hz, 1.4A Total Accessory Load: 6A @ 27.4 VDC, power-limited Standby Current: 215 mA Alarm Current: 385 mA Flexput Circuits: Six programmable circuits which can be programmed individually as: Notification circuits: 3A @ 27.4 VDC per circuit, power-limited Auxiliary power circuits: 3A @ 27.4VDC per circuit, power-limited Initiation Circuits: 100 mA @ 27.4VDC per circuit, power limited Physical Flush Mount Dimensions: 14.5W x 24.75"H x 3.9"D (36.8 W x 62.9 H x 9.8 D cm) Overall Dimensions: 16.2"W x 26.4"H x 4.2"D (40.6W x 67 H x 11.8 D cm) Weight: 28 lbs. (12.8 kg) Color Red Battery Charging Capacity: 7.0-35 AH Battery Size: 18 AH max allowed in control panel cabinet. Larger capacity batteries can be housed in RBB accessory cabinet. Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ31X (two required) S-BUS Accessories 58601R Remote Fire Annunciator Features the same 80 character backlit LCD display keypad and firefighter's keyswitch as the 5820XL. 5860 is gray and 5860R is red. 5815XL Signal Line Circuit Expander The SLC expander is used to add more addressable devices to the InteIIiKnight system. 5820XL supports three 5815XL's. Each 5815XL can support 127 devices. 5895XL Intelligent Power Module Adds 6 amps of power, 6 Flexput I/O circuits and 2 Form C relay circuits to a 5820XL system. 5496 Intelligent Power Module A 6 amp notification power expander that provides four power-limited notifi- cation appliance circuit outputs. 5880 LEDIIO Module Features 40 LED outputs, 8 normally open dry contact inputs, and one piezo output. 5865-3 and 5865-4 Remote LED Annunciator Features 30 programmable LED (15 red and 15 yellow) outputs, and a piezo sounder. The 58654 adds a silence and reset switch to the package. 5833 Relay Board Features 10 general purpose Form C relays. Used with 5880 module. 5824 SeriallParallel Printer Interface Module Provides one parallel and one RS-232 serial port for connecting a printer to the 5820XL. Use to print a real-time log of system events, detector status reports, and event history. Interfaces With building control system. Miscellaneous Accessories 5660 Silent Knight Software Suite (SKSS) User-friendly Windows software for remote programming of 5820XLs using a PC. Upload and view panel account information, event history, and detector status. 5670 Silent Knight Software Suite (SKSS) Powerful end-user facility management software allows viewing of detector status and event history via modem or direct connection. Plex-1 Dead front cabinet door with clear window to limit access to the FACP. RBB Remote battery box accessory cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16"Wx10°Hx6D (406 mm W x 254 mm H x 152 mm D) 5D505-DTS-K Remote test switch. Used with SD505-DUCTR. Provides remote key operated test function and annunciation of detector alarm. Hochiki and SK Devices See the specification sheets listed below for a complete listing of the Hochiki and 5K devices. 53624 Hochiki Devices Data Sheet 53623 SK Device Protocol Devices Specification Sheet D SILENT This document is not intended to be used for installation purposes. We try to keep our product Made In America KNIGHT information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472 Phone: (203) 484-7161, PN 350210 Rev C by Honeywell Fax: (203)484-7118. www.silentknight.com. © 2010 Honeywell International Inc. lntelliKnight & JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING. BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:0135 Page 1 of 2 CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models 5820, 5820XL, IFP-1000 Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterflow, water releasing and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 5820, 5820XL, IFP-1 000: Control Units 058200P: Motherboard 5815/5815XL: Analog Loop Expander 7628: EOL Resistor Intelliknight 5820: Enclosure 5860/5860R/RA-1000: Annunciator 5496: Power Module 5824: Serial/Parallel Interface 5895/5895XL/RPS-1000: Power Expander/Supply 5865-3/5965-4: LED Annunciator 5880: LED 10 Module 5883: Relay Interface Board SD500-ANM : Addressable Notification Module SD500-LIM: Line Isolation Module SD505-61B: Isolation Base SD-600 SDM : Smoke Detector Module RA-1 00: Remote Annunciator 3158: Reverse Polarity Module 5220: Direct Connect Module 122365: Enclosure *RBB : Battery Cabinet 5897, 5898: Power Supplies 058601: User Interlace RATING: 120 VAC Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. Rev. 04-26-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30,2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division Listing No. 7165-0559:0135 Page 2 of 2 APPROVAL: Listed as fire alarm control units for use separately listed compatible initiating and indicating devices. Also suitable for high-rise applications when used in conjunction with Model SKE-360 Voice-Tone Evacuation Unit (CSFM Listing No. 6912-0559:122); EVAX Audio Adjunct System Models EVAX-25 (CSFM Listing No. 06911-1446:100), EVAX-50 or EVAX-50E (CSFM Listing No. 06911-1446:102); EVX-2ZAor EVX-4Z Zone Splitters (CSFM Listing No. 06912-1446:101), HMX-MP or HMX-DP Voice Evacuation System (CSFM Listing No. 06911-1446:103), two-way firefighter telephone and separately listed electrically and functionally compatible initiating and indicating devices. Refer to listees Installation Instruction Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Fomerly 7170-0559:0135 Rev. 04-26-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division ___ Model 5495 SILENT Distributed Power Module ___ KNIGHT 0 In an emergency, by Honeywell you need maximum power The 5495 Distributed Power Module by Silent Knight is the most powerful and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor®,Gentex®, AMSECO®, Wheelock and Faraday - what you need to drive power- hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. And, ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost-effective notification power supply available, you need the 5495. Call Silent Knight today for more information at 1-800-328-0103. Model 5495 Distributed Power Module The 5495 is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with fire and security controls such as the Silent Knight Model 5208 Fire Control /Communicator. The 5495 is the cost- effective solution for powering notification appliances required by the Americans with Disabilities Act (ADA). The 5495 has built-in ANSI cadence pattern, which can upgrade older control panels that lack cadence capability. Features UL Listed for 6 amps of notification power Power supply's advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems Dip switches allow for easy reconfiguration 24 VDC filtered output voltage Four power-limited notification outputs; 2 Class A or 4 Class B, or I Class A and 2 Class B Additional continuous auxiliary output 3 amps per output circuit 2 inputs; 2 Class B or 2 Class A Ground fault detector/indicator Independent trouble relay AC loss delay option shuts off power to non-essential high-current accessories like magnetic door holders Built-in synchronization for appliances from System Sensor®,Gentex®, AMSECO®, Wheelock and Faraday Stand alone operation Lightweight design adds to ease of installation and reduces shipping costs Operates with most polarized, UL Listed notification devices ANSI Cadence pattern output capability built-in Connection to Local Fire Control The 5495 may be connected to a local fire control which utilizes Class A or Class B type notification circuits operating between 9 and 32 VOC. The control panel's notification circuit is connected to one of the inputs on the 5495. The control panel's notification circuit end-of-line resistor is also connected across two terminals on the 5495, which provides supervision between the 5495 and the fire control panel. Polarized audible and/or visual notification devices are then connected to the 5495 signal circuits using the 4.7k end-of-line resistors provided. Since the 5495 draws very little power from the control, it is possible to connect one 5495 to each notification circuit on the control panel and still provide full supervision of the notification circuits all the way back to the control panel. Model 5495 Distributed Power Module Approvals UL Listed MEA 429-92-E Vol XII CSFM 7300-0559:123 NFPA 72 Input voltage range: 9 - 32 VDC Battery charging capacity: 35.0 AH Ambient temp.: 320 to 120° F (0° to 49° C) Mechanical Dimensions: 12.25" W x 16° H x 3" D (30.88 cm W x 40.64 cm H x 7.62 D cm) Indicator Lights AC power on: Green Battery trouble: Yellow Ground fault: Yellow Aux trouble: Yellow Output troubles (1-4): Yellow Ordering Information 5495 Distributed Power Module Model 5495 Distributed Power Module Model 5495 Block Diagram Signal Circuit Output Signal I Signal I Input Distributed Signal 2 Signal Circuit Output Signal 2 Power ________ Signal 3 Input (Optional) Module 5495 Signal 4 Aux. Power Trouble Output Local Fire Control (Alternative to notification circuit trouble.) Supervision Current: The 5495 supervises a variety of Standby 75 mA functions including: Alarm 205 mA Low AC power Auxiliary Low battery condition power circuit: I Earth ground fault Notification Auxiliary output power limit circuits: 4 condition Output EOL supervision trouble or configuration: 2 Class A (Style Z) power limited condition at an 4 Class B (Style Y) output (1 Class A& When a trouble condition occurs, 2 Class B) the 5495 creates a trouble Amps per condition on the host control signal circuits to which it is connected. the output circuit: 3.0 (6.0 amps total) 5495 still maintains the ability to be Notification activated by the host control. In circuit output: 20.4 to 27.3 VDC addition, the 5495 provides a Form @ 3.0 amps each, C trouble relay output as an 4.7 kQ EOL alternative to using the notification resistor required circuit trouble, on each Class B Electrical Specification circuit AC input: 120 VAC at 2 amps No. of inputs 2 Output: 24 VDC at 6 amps Input configuration: 2 Class B or 2 Class A SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are FORM# 350395 Rev D subject to change without notice. For more information, contact Silent Knight © 2010 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northlbrd, CT 06472-7161 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I; FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:0123 Page 1 of 1 CATEGORY: 7300— FIRE ALARM CONTROL UNITACCESSORIESIMISC. DEVICES LISTEE: SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models 5395, *5495 and *5499 Distributed Power Module (Indicating Circuit Expander). Unit is power-limited and consists of an enclosure, printed circuit board, terminal boards, end-of-line resistors and two I2VDC, 7Ah rechargeable batteries. The unit provides up to 4 indicating zones and 1 auxiliary output. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Input: 120 VAC, 2A, 60 hz Output 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Unit must be able to provide 24 hour battery back-up as required per code. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as indicating circuit expanders for use with separately listed compatible indicating devices and polarized, 24 VDC, fire alarm control unit. Model 5495 and 5499 can generate a distinctive temporal pattern fire alarm signal as required per NFPA 72, 2002 Edition. If required, models 5395 must be use with fire alarm control unit or indicating signaling devices that can produce the temporal code pattern. Refer to listee's Installation Manual for details. NOTE: *Rece f 08-17-2006 jw F1 4-1 This listin g is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS M4TEO, Program Coordinator Fire Engineering Division - Save up to 48% in current draw* - Up to 9 models now in 1 appliance - Save up to 14% cost of installation Sleek Modern Aesthetics Finger Slide Switches Voltage Test Points Multiple Voltages 3 Audible Settings 90, 95, 99 dB - g 8 Candela Settings Wall - 15/1575/30!75/95/110/135/185 Ceiling - 15/30/60175/95/115/150/177 I Universal Mounting Base Ceiling and Wall Mounts to 5 Backbox Types COOPER Notification Strobe, Horn Strobe, and Horn Notification Appliances FIRF Ceiling Wall Description: The W,ee1ock5 Exceder Series of notification appliances feature a sleek modem design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock5 ExcederTm Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock® Excedefrm Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from felling during installation. Environmentally Friendly Low Current Draw Compatibility and Requirements - Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol - Compatible with UL *Regulated Voltage" using filtered VOC or unfiltered VRMS input voltage - Strobes produce 1 flash per second over the "Regulated Voltage" range "Compared to competitive models Patented Compared to previous models NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONVCT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION ANDIOR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU ANDIOR OTHERS. General Notes: General Notes: Strobes are designed to flash at I flash per second minimum over their Regulated Voltage Range". All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%) UL 464(85% UL 1971). Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Low Strobe Ratings per UL Standard 1971 Current Draw Fewer Power Supplies 24 VDC /24FWR 12VDC Model Regulated Voltage RangeVDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 ST 8.0-33.0 0.057 0.070 0.085 0.135 0.163 0.182 0.205 .. 0.253 0.110 0.140 STC 8.0-33.0 0.061 0.085 0.103 0.135 0.163 0.182 0.205 0.253 0.110 Horn Strobe Ratings per UL 1971 & Anechoic at 24VDC ____ UL Max Currenr at I=dBA 24VDC 12VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.082 0.095 0.102 . 0.148 0.176 0.197 .. 0.242 . . 0.282 0.125 0.159 HSC . 8.0-33.0 0.082 0.102 0.141 0.148 0.176 -- UL Max Current' .. . .....0.197 0.242 0.282 ... ., 95 dBA aAnechoic 0.125 24VDC 12VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.073 0.083 0.087 0.139 0.163 0.186 :• . 0.230 0.272 0.122 0.153 HSC 8.0-33.0 0.073 0.087 0.128 0.139 0.163 0.186 .... 0.230 0.272 ..- UL Max Current- at Anechoic S dBA 0.122 24VDC 12VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 ..U. 15 15/75 Range VDC HS 8.0-33.0 0.065 0.075 0.084 . 0.136 0.157 0.184 0.226 .. .. 0.267 0.120 0.148 HSC 80-33 0 0.065 0.084 0.120 0.136 0.157 0184 0226 0267 0120 Horn Ratings per UL Anechoic - - - Model Regulated Voltage Range VDC 99dB 9SdB 90 dB HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 HNC 8.0-17.5 0.047 0.026 0.017 * UL max current rating is the maximum RMS current within the listed voltage range (16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. Specification & Ordering Information Sync WI Strobe OSM or Mounting Model 12124 VDC* Candela Wheelock Power Options Supplies HSR 1511575130175I95I1101135I185 X X UMB HSW 15/1575I3Ol75I95I11OI135I185 X X UMB HSRC 15I3OI6O!7519511151150I177 X X UMB— HSWC 15I3O/6OJ75I95I115J15OI177 X X UMB** STIR 15I1575I30ff51951110I135I185 X X UMB STW 15/1575/30/75/95/110/135/185 X X UMB** STRC 15/30160175I95/115/150/177 X X UMB STV 15130160/75195/1151150I177 X X UMB X HNR X UMB** HNW X X UMB HNRC X X UMB HNWC X - X UMB** NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard terms and conditions. Architects and Engineers Specifications The notification appliances shall be Wheelock Excederl Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15175 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 1 00m European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24"H x 4.58" Wx 2.19"D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68"x 2.63"D. Series HNC ceiling shall have a diameter of 6.68"x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock's DSM Sync Modules, Wheelock Power Supplies or other manufacturer's panels with built-in WheelocV Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization protocol. Wall Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM Ceiling Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM RHMA WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder - Spec Sheet 6111 Cooper Notification is Wheelock (CJ SAFEPATH wAv) COOPER Notification CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0168 Page 1 of 1 CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc.273 Branchport Ave, Long Branch, NJ 07740 Contact: Frank Hartzog (732) 962-7839 Fax (732) 962-7856 Email: frank.hertzog@cooperindustries.com DESIGN: Exceder Series: Models ST strobe, HS horn strobe and HN horn. Model ST is a synchronous and non-synchronous strobe light Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or W (while). Additionally, a may be added for ceiling models and/or a - NR' may be added for non-resettable models. For non -NR models and optional 'S' for silver fascia may be added *• Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDCI24VDCIFWR Candela (wall)*: 15, 15/75, 30, 75, 95, 110, 135 & 185 Candela (ceiling)*: 15, 30,60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to Iistee's Installation Instructions Manual for details. Rev. 9-24-09 fm * This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not / an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2011 Listing Expires June 30, 2012 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division