Loading...
HomeMy WebLinkAbout1950 SILVERLEAF CR; ; AS080102; Permit11/10/2020 AS080102 Permit Data • City of Carlsbad Sprinkler Permit Permit No: AS080102 • 1950 SILVERLEAF Job Address: Status: ISSUED CR Permit Type: SPRINK • Applied 6/26/2008. Parcel No: 2550121600 • Approved: 7/2/2008 Lot #: 0 Reference No.: • • Issued: 7/2/2008 PC #: • Inspector: Project Title: LA COSTA GLEN - RECREATION BLG TI FIRE SPRINKLER PLAN CHECK & INSPECTIONS • • Applicant: Owner: AAA FIRE SPRINKLERS • • CONTIN.UINGLIFE COMMUNITIES LLC C/O RICHARD ASCHENBRENNER 20942 JAPATUL RD 800 MORNINGSIDE DR ALPINE CA FULLERTONCA 619-445-9898 • • Fees ($) Add'I Fees ($) Total ($) Balance ($) 130. 0 130 0 1/1 tqC0 /Fire & Building I Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Series 7V-FRB —2.8,42,5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Tyco® Series TV-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pen- dent Sprinklers described in this data sheet are quick response - standard coverage, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels. shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20(1/2 inch NPT) or Style 30(3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- IMPORTANT Always refer to Technical Data Sheet TFPTOO for the 'INSTALLER WARNING that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. tamed when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TYII3I - Upright 2.8K,, II2MNPT 1Y1231- Pendent 2.8K, 1I2"NPT TY2131 - Upright 4.2K, II2NPT TY2231 - Pendent 4.2K, II2NNPT 1Y3131 - Upright 5.6K, 112NPT TY3231 - Pendent 5.6K, II2NPT 1Y4131 - Upright 8.0K, 314"NPT 1Y4231 - Pendent 8.0K, 314NPT TY4831- Upright 8.0K, 112"NPT TY4931- Pendent 8.0K, 1I2"NPT Page 1 of 10 AUGUST, 2007 TFPI7I 2-3/16" (55,6 mm) I TFPI 71 ii SSP DEFLECTOR * I-'"-- 2-7/8" (73.0 mm) DIA. - PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TYII3I) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT ESCUTCHEON PLATE SEATING SURFACE 7/16"(11,1 mm) STYLE 10 or 20 1/2" NOMINAL RECESSED ssu NPT MAKE-IN ESCUTCHEON DEFLECTOR Page 2 of 10 ESCUTCHEON PLATE SEATING 1/2" SURFACE NPT 2-1/4" (57.2 mm) I (LI 7/16" (11.1 mm) STYLE 10 or 20 NOMINAL RECESSED ssu MAKE-IN ESCUTCHEON DEFLECTOR 7/16" 1 (111,11 mm) I NOMINAL j WRENCH I 2-3/16 (55,6 mm) - FLATS lIi" MDT SSP DEFLECTOR * PENDENT 6* 7/16" (11,1 mm) NOMINAL MAKE-IN 2-3 16" W WRENCH (55,6 FLATS - 2-7/8" (73.0 mm) DIA. 1/2" NPT - " '. ,I RECESSED PENDENT.. UPRIGHT CROSS SECTION -Frame 3-Sealing 4 - Bulb 6 . Deflector * Temperature Tating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 112 INCH NPT TFPI7I Page 3 of 10 STYLE 10or20 RECESSED ESCUTCHEON CROSS SECTION - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE -3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 7116" (11.1 mm) PLATE SEATING NOMINAL SURFACE 1/2" NPT MAKE-IN T_ 2-3/16" (55,6 mm) f (} 1-1/2" (38.1 mm) 1 12 WL SSP DEFLECTOR * 2-7/8"(73,0 mm) DIA. DEFLECTOR I (N( " mm) I NAL -IN 2-3/16" WRENCH (55,6 mm) FLATS 12" NPT PENDENT RECESSED PENDENT UPRIGHT 6* 5 4 2 3 ESCUTCHEON 1/2" (12,7 mm) STYLE 30 or 40 PLATE SEATING ,, NOMINAL RECESSED SURFACE NPT MAKE-IN ESCUTCHEON LATS WRENCH SSP DEFLECTOR * 2-7/8" (73,0 mm) DIA. PENDENT RECESSED PENDENT SSU * DEFLECTOR 6*1 I 1/2" I (12,7 mm) I : 4 NOMINAL MAKE-IN i 2-114" (57,2 mm) I 3 3/4" NPT UPRIGHT CROSS SECTION 1 - Frame 3- Sealing 4- Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression ' orifice seat on frame. Screw FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 314 INCH NPT Page 4 of 10 TFPI7I 7/16"(11.1 mm) NOMINAL SSU MAKE-IN DEFLECTOR 1/2" NPT 2-1/4" (57,2 mm) 1-9/16" WRENCH (39,7 mm) FLATS = "'- SSP* DEFLECTOR PENDENT 1 - Frame 3 - Sealing 4-Bulb 6 - Deflector 2 - Button Assembly 5 - Compression Screw CROSS UPRIGHT SECTION * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (7Y4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB. and NYC Approved. (Refer to Table A and B for complete approval information including corro- sion resistant status.) Maximum Working Pressure Refer to Table C. Discharge Coefficient K = 2.8 GPM/p5i1"2 (40,3 LPM/bar"2) K = 4.2 GPM/psi"2 (60,5 LPM/barl'2) K = 5.6 GPM/psi'/2 (80,6 LPM/barl'2) K = 8.0 GPM/psi112 (115,2 LPM/bar112) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ...............Glass Compression Screw .....Bronze' Deflector .......Copper/Bronze Bushing (K=2.8) .......Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized' by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Appibval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. E I .4- Page 5 of 10 TFPI7I SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB LIQUID NATURAL BRASS CHROME PLATED I WHITEtm JPOLYESTER 2.8 1/2' PENDENT (TY1231) and UPRIGHT (TYII3I) 135F/57C Orange 1, 2, 3, 5 155°F/68°C Red 175F179°C Yellow 200°F193°C Green 286°F/141°C Blue NPT 135FI57°C Orange 1, 2, 5 RECESSED PENDENT (TY1231)* Figure 6 155°F168°C Red 175°F179°C Yellow 200°F/93"C Green 135F/57°C Orange RECESSED PENDENT (TY1231) Figure 7 155°F/68°C Red 175F179°C Yellow 200F/93"C Green 4.2 1/2" NPT PENDENT (TY2231) and UPRIGHT (1Y2131) 135°F/57C Orange 1,2 155°FI68C Red 175°F/79°C Yellow 200FI93°C Green 286°F/141"C Blue 135°F/57°C Orange RECESSED PENDENT (TY2231) Figure 8 155°F168"C Red 175°F179C Yellow 200"F/93C Green 135°F/57°C Orange RECESSED PENDENT (TY223I) Figure 9 155F/68"C Red 175FI79C Yellow 200"F/93°C Green NOTES: Listed by Underwriters Laboratories. Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Re- sponse Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354-01-E. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprin- klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Installed with Style 10 (112" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 112" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2K-FACTOR SPRINKLERS Page 6 of 10 TFPI7I SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED I WHITE JPOLYESTER LEAD COATED - 5.6 1/2" PENDENT (TY3231) and UPRIGHT (TY3131) 135°F/57°C Orange 1,2, 3.4.5.6,7 1,2,3,5 155"F/68"C Red 175"F/79"C Yellow 200"F/93°C Green 286"F/141"C Blue NPT 135°F/57"C Orange 1,2,4,5 N/A RECESSED PENDENT (TY3231) Figure 10 155"F/68"C Red 175°F/79°C Yellow 200"F/93"C Green 135"F/57"C Orange 1,2,3.4.5 N/A RECESSED PENDENT (TY3231)" Figure 11 155"F/68°C Red 175°F/79°C Yellow 200°F/93"C Green - 8.0 3/4- PENDENT (TY4231) and UPRIGHT (TY4131) 135"F/57"C I Orange 1,2,3,4.5.6.7 1, 2, 5 155"F/68"C Red 175"F/79"C Yellow 200"F/93°C Green 286"F/141"C Blue NPT 135"F/57C Green 1,2,4,5 N/A RECESSED PENDENT (1Y4231)" Figure 12 155°F/68°C Orange 175°F/79"C Red 200"F/93"C Yellow RECESSED PENDENT (TY4231)" Figure 13 135"F/57"C Orange 1,2, 3,4, 5 N/A 155"F/68C Red 175"F/79"C Yellow 200F/93C Green - 8.0 1/2" NPT PENDENT (1Y4931) and UPRIGHT (TY4831) 135"F/57"C Orange 1, 2,4, 5, 6 1, 2, 5 155"F/68C Red 175F179"C Yellow 20017/93"C Green 286"F/141"C Blue NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use In Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k!04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2" NPT) or Style 30 (3/4 NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available - TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS TFPI7I Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD BRASS I PLATED-' POLYESTER COATED PENDENT (TY3231) and 2.8 UPRIGHT (TY3131) . . 175 PSI (12.1 BAR) N/A 1/2" RECESSED PENDENT NPT (TY323) PENDENT (TY4231) and 4.2 UPRIGHT (TY4131) 175 PSI (12,1 BAR) N/A RECESSED PENDENT NPT (TY4231) PENDENT (TY3231) and 250 PSI (17.2 BAR) 175 PSI (12.1 BAR) 5.6 UPRIGHT (TY3131) OR 1/2" 175 PSI (12.1 BAR) RECESSED PENDENT NPT (TY3231) (SEE NOTE 1) N/A PENDENT TY4231) and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 8.0 UPRIGHT (1V4131) RECESSED PENDENT NPT (TY4231) - .. N/A 80 PENDENT (TV4931) 1/2" and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) NPT UPRIGHT (1Y4831) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and , the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE Installation The Series TY-FRB Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135"F/57°C to 3/32 inch (2,4 mm) for the 286°F/14 1"C temperature ratings. A leak tight 1/2 inch NPTsprinklerjoint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 14). With reference to Figures 1, 2, 3, 4, and 5, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. - Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 15). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed Page 8 of 10 - 2-718"DIA. 5/8±114" (73.0 mm) -3/4" (19.1 mm) (15.9±6.4 mm) 2-1/4" DIA. I 1/4" (6.4 mm) I FACE OF MOUNTING I PLATE FITTING I 1/8" I SPRINKLER I (3,12 mm) MOUNTING __ SURFACE/ CLOSURE SERIES 1-5116"(33,3 mm) TY-FRB 13/16" (20,6 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL-ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. 5/80/4" (73,0 mm) 3/4"(19,1 mm) (15,9±6,4 mm) - 2-1/4" DIA. I 1/4"(6,4 mm) FACE OF MOUNTING SPRINKLER PLATE I FITTING 1/8" I (3,2 mm) .2mm) I MOUNTING t SURFACE CLOSURE SERIES 1-1/4"(31,8 mm)T TVFRB 3/4'(19,1 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT TFPI7I - 2-7/8" DIA. - 1/2±1/8" I (73,0 mm) 1/2"(12,7 mm) r (12.7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) I SPRINKLER PLATE I FACE OF 57,2 mm) MOUNTING I I FITTING 1/8" I (3,2 mm) SURFACE/ 6" (33.3 mm) t " t MOUNTING / I CLOSURE SERIES TY-FRB 1-1/16"(27.0 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. - (73,0 mm) 1/2±1/8" I 1/2"(12.7 mm) r (12,7±3,2 mm) - 2-1/4" DIA. I 1/4" (6,4 mm) I I FACE OF (57.2 mm) '" MOUNTING /A; 1/8" I I SPRINKLER PLATE I I FITTING / (32mm) I T_ \ MOUNTING f I SURFACE SERIES 1-1/4"(31.8 mm) ] CLOSURE TYFRB 1" (25,4 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non-operation in the event of a fire or inadvertent opera- tion may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been corn- S TFPI7I Page 9 of 10 2-7/8"OIA. - (73.0 mm) 3/4" (19,1 mm) 2-1/4" DIA. 1/4"(6,4 mm) I (57,2 mm) MOUNTING 1/8" (3.2 mm) MOUNTING SURFACE CLOSURE SERIES 1.1/4"(31.8 mm) 3/4"(19,1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. 5/8±1/4- (73.0 mm) .3/4"(19,1 mm) (15,96,4 mm) 2-1/4" DIA. 1/4"(6.4 mm) I FACE OF SPRINKLER - (57.2 mm) MOUNTING I PLATE FITTING ______________ (3.2 mm) MOUNTING J~ SURFACE/7 CLOSURE SERIES 1-5116'(33,3 mm)! TY-FRB 13/16"(20.6 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT 2-7/8"DIA. - 1/2±1/8" I (73,0 mm) 1/2"(12,7 mm) r (12,7±3.2 mm) 2-1/4" DIA. I 1/4'(6.4 mm) I SPRINKLEqR I PLATE I FACE OF mm) MOUNTING I I FITTING / 1/8' __ I \ MOUNTIN SURFACESERIES 1-1/4" (31,8 mm) CLOSURE TYFRB V (25,4 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2.7/8" DIA. (73,0 mm) 1/2'(12.7 mm) 2-1/4"DIA. 1/4" (6.4 mm) I (57.2 mm) MOUNTING ; rLnu C I 1/8 I (3.2 mm) 1-5/16"(33,3 mm)t 1.1/16' (27.0 mm) FIGURE 13 SERIES TY'FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING 1/2±1/8" (12.7±3.2 mm) FACE OF SPRINKLER FITTING T__\_ MOUNTING SURFACE CLOSURE SERIES rY-FRB plated, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END B' USED FOR 3/4'S NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH Inspection Service in accordance with local requirements and/or national codes.