Loading...
HomeMy WebLinkAbout6860 AVENIDA ENCINAS; ; FA120046; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA120046 6860 AVENIDA Job Address:. Status: PENDING ENCINAS Permit Type: FALARM Applied 11!1512012 Parcel No: 2144501900 • • Approved: Lot #: 0 • • Reference No: • • Issued: • PC #: • • • Inspector: Project Title: 'KAISER MAMMOGRAPHY T.I. T.I. Applicant: • Owner: POWER COMMUNICATION SYSTEMS KAISER FOUNDATION HEALTH PLAN INC 4643-A MISSION GORGE PL • • SAN DIEGO, CA • • 393 E WALNUT ST PASADENA CA 619-583-7400 .• Fees ($) Add'I Fees ($) Total ($) Balance ($) 286 0 • 286 • • 0 • I .NEC POWER COMMUNICATION SYSTEMS, INC. flSR I- BUILDING CON NEC TI oar SALES - SERVICE - ENGINEERING Public Address • Paging • Intercom • Fire Alarm • Nurse Call • CCTV I I I SUBMITTAL FIRE ALARM SYSTEM KAISER PERMANENTE - CARLSBAD MAMMOGRAPHY & BREAK ROOMS 6860 AVEN IDA ENCINAS CARLSBAD, CA 92008 cV OWNER: KAISER PERMANENTE ELECTRIC CONTRACTOR: NEAL ELECTRIC FIRE ALARM CONTRACTOR: POWER COMMUNICATION SYSTEMS, INC. P.O. Box 600066, San Diego, CA 92160-0066 • 4627-A Mission Gorge Place, San Diego, CA 92120-4133 (619) 583-7400 • Fax: (619) 583-0647 License No. 636431-C7/C10 I I TABLE OF CONTENTS I LIST OF MATERIAL . . I UL CERTIFICATE . . . NICET CERTIFICATE . . . LICENSE . . . . I BUSINESS CUT SHEETS I 2584 ZH-MC-CR, ZR-MC-CR. 2585 MOUNTING APPLIANCES I C.S.F.M. LISTINGS I 7125-0067:0248 ZH-MC-CR . 7125-0067:0252 ZR-MC-CR . I WARRANTY . . I I I I I I I I I I • • • • 1 • • • • 2 • • • • 3 • • • • 4 • • • • 5 • • • • 6 • • • • 7 • • • • 8 • • • • 9 I I I LIST OF MATERIAL MODEL NO. MANUFACTURER DESCRIPTION QTY I ZH-MC-'CR SIEMENS FIRE SAFETY Z HORN MULTI-CANDELA CEILING RED 1 ZR-MC-CR It Z STROBE MULTI-CANDELA CEILING RED 3 I I Li Li I I I I I Li I I 1 P I Applicant ID No: 967165-001 Service Center No 0 U L Expires: 31-MAR-2013 I CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters I Laboratories Inc (UL) in its Product Directories as eligible to use the UL Listing Markin connection with Certificated Alarm Systems The only evidence of complianc Certi e with UL's requirements is the issuance of a UL Certificate for the Alarm System and the ficate IS current under UL's Certificate Verification Service I This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of ,a UL listed or Classified Alarm Transport Company is specified on the Certificate I H I Listed Service From SAN DIEGO, CA Alarm Service Company (967165-001) Service Center (967165-001) POWER COMMUNICATION SYSTEMS INC POWER COMMUNICATION SYSTEMS INC SUITE A SUITE A I 4627 MISSION GORGE PL 4627 MISSION GORGE PL SAN DIEGO 6A'92120 SAN DIEGO CA 92120 ' The Alarm Service Company is Listed in the following Certificate Service Categories File - Vol No CCN Listing Category I S3669 -1 UUJS [Signal and.Fire Alarm Equipment and Services] (Protective Signaling Services) Loçl, Auxiliary, Remote Station and (LOP lel~r~ ***THIS CERTIFICATE EXPIRE 0N314AR-2013 * "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" 4\ NATIONAL INSTITUTE FOR CERTIFICATION ENGINEERING TECHNOLOGIES ® /NUCET'\® Providing Certification Programs Since 1961 BE IT KNOWN THAT Ernest Power, III IS HEREBY AWARDED CERTIFICATION AT LEVEL IV IN FIRE PROTECTION ENGINEERING TECHNOLOGY FIRE ALARM SYSTEMS BASED UPON SUCCESSFUL DEMONSTRATION OF REQUISITE KNOWLEDGE, EXPERIENCE, AND. WORK PERFORMANCE AS SET FORTH BY THIS INSTITUTE. Certification Valid through September .01, 2014 CERTIFICATION NUMBER 77846 CHAIRMAN OF THE NICET BOARDOF GOVERNORS 0 A DI\IISIONQF THE NATIONAL SOCIETY OF PROFESSIONAL ENGINEERS — — — — — — — — — — — — — — — — — — — IECI POWER COMMUNICATION SYSTEMS, INC. nSE:R U................. SALES - SERVICE - ENGINEERING Public Address • Paging • Intercom • Fire Alarm • Nurse Call • CCTV I I I . State Of California %~-.2ONTRACTORS STATE LICENSE BOARD/'''\ Consumer ACTIVE LICENSE Affairs .Licen63643i E-w CORP POWER COMMUNICATION SYSTEMS I . INC I C-7 C1 0 I FoOrefian 01/31/2014 www.cslb.ca.gov I I P.O. Box 600066, San Diego, CA 92160-0066 • 4627-A Mission Gorge Place, San Diego, CA 92120-4133 (619) 583-7400 • Fax: (619) 583-0647 License No. 636431-C7/C10 SIEMENS Catalog Sheet Fire Safety & Security Products '08 Series Notification Appliances ZH & ZR - Strobes, Horns, & Horn I Strobes FApprication:III Indoor (ZR 8 ZH Series ZR Series Product Overview - Strobes can be synchronized using the Siemens DSC sync modules, FS-250 panel, XLS panel, or PAD-3 power supply with built-in sync protocol - Selectable Continuous Horn or Temporal (Code-3) Tones with 90 or 95 dBA selectable setting (ZH) - Ceiling-mount models feature field-selectable Candela settings of 1513017519 5cd and 11 51177c - Wall-mount models feature field-selectable Candela settings of 15!30!75/110cd and 1351185cd - Base plate is protected by a disposable cover, and the appliances can quickly snap onto the base after the walls are painted - Strobes produce 1 flash per second - "Special Applications" listed with Siemens panels - EZ Mount Universal Mounting Plate (ZBB) - uses single plate for ceiling and wall mount installations - EZ Mount design - with separate base plate - provides ability to pre-wire the base and test the circuit wiring before the walls are covered - ®UL Listed & @ULC Listed; FM, CSFM & NYMEA Approved - ADA! NFPA compliant Specifications General - Audible/Visual notification appliances shall be listed for indoor use only - Appliances shall be listed under ®UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired) and ®UL Standard 464 (Fire Protective Signaling) - Appliances shall use a universal back plate, which shall allow mounting to a single-gang, double-gang, 4-inch-square, 4"-octal, or a 3-112"-octal backbox - Two-wire appliance wiring shall be capable of directly connecting to the mounting back plate - Continuity check shall occur for entire NAC circuit prior to attaching any audible / visual-notification appliances - Dust cover shall fit and protect the mounting plate - Dust cover shall be easily removed when the appliance is installed over the back plate - Removal of an appliance shall result in a trouble condition by the Fire Alarm Control Panel (FACP) 108 Series Notification Appliances 2584 SIEMENS Industry, Inc. Building Technologies Division I I I E I I Mountu Specifications - (continued) Strobes - Strobe appliances shall produce a minimum flash rate of 60 flashes per minute (1 flash per second) over the Regulated Input Voltage Range, and shall incorporate a Xenon flashtube enclosed in a rugged Lexarl® lens - Strobes shall be available with two or four field-selectable settings in one unit, and shall be rated - per ®UL 1971 - for up to: 15130175111 0cd for wall mounted 135/185cd for wall mounted 1 5!30!75195cd for ceiling mounted 11 511 77cd for ceiling mounted - Strobes shall operate over an extended temperature range of 32°F to 120°F (0°C to 490C), and be listed for maximum humidity of 95% RH - Strobe inputs shall be polarized for compatibility with standard reverse-polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) Audibles and Audible I Strobe Combinations - Horns and horn I strobes shall be listed for Indoor use under ®UL Standard 464 - Horns shall be able to produce continuous synchronized output or a temporal code-3 synchronized output - Horns shall have at least 2 sound-level settings of 90 and 95 dBA Synchronization Modules - The strobe portion, when synchronization is required, shall be compatible with DSC sync modules, FS-250 panel, XLS panel, or PAD-3 power supply with built-in sync protocol - The strobes shall not drift out of synchronization at any time during operation - Audibles and strobes shall be able to synchronize on a 2-wire circuit with the capability to silence the audible, if required - Strobes shall revert to a non-synchronized flash-rate, if the sync module or Power Supply should fail to operate (i.e. - contacts remain closed) - All notification appliances shall be listed for Special Applications: Strobes are designed to flash at 1-flash-per-second minimum over their "Regulated Input Voltage Range" > NFPA-72 specifies a flash rate of 1-to-2 flashes per second, and ADA Guidelines specify a flash rate of 1-to-3 flashes per second All candela ratings represent minimum-effective Strobe intensity, based on ®UL Standard 1971 Series ZH Strobe products are listed under ®UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%) Series ZH horns are listed under ®UL Standard 464 for audible signal appliances (Indoor use only) SIEMENS Industry, Inc. Building Technologies Division Mounting Diagram (Shown In Inches) Mounting Options OPTIOINAL SECURING SCREWS SIDE OPENIXG FM FIAT SCREWDRIVER Fioxe 3: wt.c'Aon Finn 4: ?eoteI (See vc€o B be'ow) 1. Instal mount,cg pae as sBtonn in flgure Ito a single-gang, Important Device cny has one ricwtting orientafcn. ?.latth the double-gang. 4 square. 4 octagon. OT a 3W otagcn bbcx lop of the base to the top of the device. with the provided pars head screw!. To remove dust cover. If it is desired lo fijr.her secure the device to the base, then two place thumb and index finger on cop edges of cover and pull off optional screws are provided. re install these screws punch otti cover. the screw holes located at the top and bottom of the derrce. Connect field wiring per figures 2 and 3. S. To remove the appliance, push a small f.at-blaced screwdriver Address vires ba into backbox. into the side opening. The screvidiver must clear the snap 4. Place dust cover over mounting ;Pate to protect the terminas release opening by/.' to disengage the snap. Do not pry off while performing wiring ccniinuicydceck. housing with the screw driver. Apply pressure with screwdriver. 5.. Remove dust cover before snapping or installing the appliance inserted in either side opening, as shown in Fig 4 to re—'ease the onto the mounting We per fig 3. housing. Technical Data I Continuous II High I Horn II Low I Code 3 Horn or II High I March lime' Low 'Available in ZH Horn Current Draw In Horn 16-33 Volts (Amps) Setting I DC High' 0.044 I Low' 1 0.018 I FWR High' 1 0.075 r LOW' 1 0.045 'arent Draw is the same for the Continuous Item. Code 3 Hem and March Time Settings. ZH and ZH-MC Horn Reverberant dBA per ()UL464 [ZH-MC and ZH at 24V] 16.OV 24V I 33.0V 83 87 I 90 77 81 I 83 79 82 I 86 72 1 76 I 79 sync mode only SIEMENS Industry, Inc. Building Technologies Division Technical Data - (continued) Models ®UL Listed Models and Ratings Operating Voltage (Special Appilcabon) [Per ®ULI 971] (VDCNRMS) Voltage Range ULC L S6 (VDCNRMS) Horn - Mounhng strobe Candela ________ ZRMC 16.0-33.0 20.0-31.0 - Wall 15130/751110 ZR-HMC 16.0-33.0 20.0-31.0 - Wall 135/185 ZR-MC-C 16.0-33.0 20.0-31.0 - Ceiling 15/30/75/95 ZR-I-IMc-C:16.0-33.0 20.0-31.0 - Ceiling 115/177 ZH-MC 16.0-33.0 20.0-31.0 X Wall 15/30175/110 ZI4HMC 16.0-33.0 20.0-31.0 X Wall 135/185 ZH-M" 16.0-33.0 20.0-31.0 X Ceiling 15/30/75/95 ZH-HM" 1 16.0-33.0 20.0-31.0 X Ceiling 115/177 ZH 1 16.0-330 20.0-31.0 X WallorCeiling - - AvaJIabre In recand white DC 16-33VDC FWR 16-33VRMS '@UL current Ratings (ZRS o be Only) Maximum RMS Current (AMPS) MC HMC MC-C HMC-C 15cd I 30cd I 75cd 1110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd 0.064 0.098 0.175 0.233 0.318 0.445 0.069 0.111 0.200 0.264 0.318 0A45 0.108 0.164 0.268 0.368 0.482 0.684 0.117 0.180 0.297 0.398 0.482 0.684 Horn Setting ®ULCurrentRatings ZH Horn/Strobe.J Maximum :RMS Current (AMPS) MC HMc_J MC-C HMC-C l5cd 30cd 75cd llOcd 135cd 185ed1I15cd 30cd 75cd 95cd ll5cd 177cd DC 1 16-33VDC High' 0.078 0.113 0.195 0.259 0.371 0.087 0.131 0222 0.292 0.371 0.506 Low 0.070 0.107 0i88 0246 0.324 0.075 0.121 0.213 0.277 0.324 0.455 IFWR 16-33VRM., High' 0.141 0.200 0302 0406 0.521 0.216 0.331 0.436 0.521 0.722 Low * 0.123 0.179 0.290 0.391 0.497 0.699 i]_0.149 0.131 0.195 0.319 0.421 0.497 0.699 Code 3 Horn and March Time Settings Details for Ordering -. (Including Mounting Options & Agency Approvals) Aaencv Aoorovals Model Number Part Number Description . Mounting Options' UL UIC FM CSFM ZH-R 500-636159 Z Horn: Red B.D,E.F X X X X ZH-W 500-636160 Z Horn: White B.D,E,F X X X X ZH-MC-R 500-636161 Z Horn: Multi Candela (Wall), Red B,D,E.F X X X X ZH-MC-W 1 500.636162 Z Horn: Multi Candela (Wall), White B.D,E,F I X X X X ZH-HMC-R 500.636163 ZHorn: Hi Multi Candela (Wail),Red B,D,E,F X X X X ZH-HMC-W 500-636164 ZHorn: Hi Multi Candela (Wall), White B,D,E,F X X X X ZH-MC-CR 500-636165 Z Horn: Multi Candela (Ceiling), Red B,D,E,F X X X X ZH-MC-CW 500-636166 Z Horn: Multi Candela (Ceiling), White B,D.E,F X X X X ZH-HMC-CR 500-636167 Z Horn: Hi Multi Candela (Ceiling). Red B,D.E.F X X X X ZH-HMC-CW 500-636168 Z Horn: Hi Multi Candela (Ceiling), White B,D,E,F X X X X ZR-MC-R 500-636169 Z Strobe: Multi Candela (Wall),Red . B,D,E,F X X X X ZR-MC-W 500-636170 Z Strobe: Multi Candela (Wall). White B,D.E,F X X X X ZR-HMC-R 500-636171 Z Strobe: Hi Multi-Candela (Wall), Red B.D,E,F X X X X ZR-HMC-W 500-636172 Z Strobe: Hi Multi-Candela (Wall), White B.D.E.F X X X X ZR-MC-CR 500-636173 Z Strobe: Multi Candela (Ceiling), Red B,D,E.F X X X X ZR-MC-CW 500-636174 Z Strobe: Multi Candela (Ceiling), White B,D,E,F X X X X ZR-HMC-CR 500-636175 Z Strobe: Hi Multi Candela (Ceiling). Red B,D,E,F X X X X ZRS-HMC-CW 500-636176 Z Strobe: Hi Multi Candela (Ceiling). White B.D,E.F X X X X ZBB-R 500-636193 Accessory -(includes base, dust cover, mounting screws and installation sheet) ZBB-W 500-636194 Accessory- (Includes base, dust cover, mounting screws and installation sheet) X = listed I approved * = Refer to catalog sheet #: 2585 for detailed mounting options Notice: This marketing catalog sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Femwood Road 2 Kenview Boulevard cIrRIrftIc lrirl.ictrsi Iror Florham Park NJ 07932 Rr,mntr.n flnt,nn Building Technologies Division Tel: (973)36 (Sill L615E4!Canada December 2009 FAX: (908) 547-6877 Printed in U.S.A. Tel: (905) 799-9937 Supersedes sheet dated 7107 URL: www.SBT.Siemens.comIFlS FAX: (905) 799-9858 Catalog Sheet SIEMENS Fire Safety & Security Products '08 Series Notification Appliances Mounting Options Mounting Diagrams I Mounting Matrixes I Mounting Notes ARCHITECT AND ENGINEER SPECIFICATIONS (A) UNIVERSAL MOUNTING PLATE 4" SQUARE, DEEP, FLUSH (BO) (I) WPBBS ORDER CODE— RED: 500-636137 0 0 0 () Plascbackbox for surface mcvnEng AS series weatherproof. outdoor products. c0 j s 0 24 lop 0 91 AS Mounthg 4rrin:we'&EiA8 w1lescol:ee) Used w1h Series Used with Sefes AN, AS Used ',rh Sezies AS, 56.B10,HS, MBDCMH115, Mitt AS (iteatherproof) (B) SINGLE-GANG, FLUSH (50) (C) SINGLE-GANG, SURFACE (80) (J) BBS BACKBOX NH, NS.SETSF, SETULC. ST. ZH.ZR ORDER CODE— RED: 500-636110 Standard steel beckbox wIh knockouts DOUBLE-GANG, FLUSH (80) for interior surface mounting, oonceaed condtñt rnountg orsemi-1ush app N8 3 V-411 0 HOLES 33m, Deep PRDEDWiTtl tJTa FOR Used with Seces Used with Serces Used with Seres Used with Series 10 AH, AS.86, 5 ' AN, AS, MKNH, NS, SE 2H,ZR MH AN, AS. HS. MTh, NH,ST, ZN, ZR MH 15,MTN-15-115. NH, ST (D) 4' SQUARE, FLUSH (50) DOUBLE-GANG SURFACE (80) (K) WBBS WEATHER RESISTANT BACKBOX ORDER CODES— RED: 500-636129 WHITE: 500-636131 Sturdy die cast housing, threaded conduit hole and () • and knockout for outdoor applications. I cLp L 15 Z!tt:441 DU)T _______ 4:-t' -S 0. GIANG Used wth Series I 34 MI, AS. B&B1O,HS,MBDCji1H1 15, MTI4 Used with Series Used with Series NH, NS.SETSF. SET-ULC.ST,2H,ZR AN, AS, NH, NS, ST AN,B6,B10,MSDC.M1115,MTH-15-115 SETSF '08 Series Notification Appliances 2585:. SIEMENS Industry, Inc. Building Technologies Division (1) ISPS2 SURFACE ADAPTER (P) SBBS BACKBOX (T) WPSBBS ORDER CODES-WHITE: 500.636195 ORDER CODES— RED: 600-636119. ORDER CODES— RED: 600-636139, RED: 500-636196 WHITE: 500636120 WHITE: 500-636140 .44 For surface mounting speakers, chimes, and electronic applications. II II - r -511' -1 II-. { 0 j:T41L 12p— l4!4T 4.5i32 KNCCtCuT3 - •- 1 3F16 4 52 NOOUT3 (EACU EIE) (EACI 5}DE) Used with Series Used w9h Series Used with Series HS PITh SET 66.810. CH. SEF. SEI. SETFL ST-WP HS, MBDC. MTh, NH, NS, ST (M) MT-SUR-BOX BACKBOX (Q) 4" SQUARE DEEP WI EXTENSION (U) 5" SQUARE BACKBOX WI ORDER CODES- RED: 500-693168 RING, FLUSH (BO) EXTENSION RING, FLUSH (BO) WHITE: 500-636118 I cP OEM- V,o-E ILI_1. Used with Series CH,SE,SEF.SETFL.SET 0 (R) SFPS SEMI-FLUSH PLATE 1-I 0 Used with Series HS. SET ORDER CODES— RED: 500-636124, Used with Series (NTH. MTWP: For surface mounting on MT products.) WHITE: 500-636125 CH.SE,SEF. SET Stamped alumluan surface wal plate, which mounts behind the basic untt, (N) DBBS BACKBOX (V) SSB-4 CEILING SUPPORT BRIDGE ORDER CODE - RED: 500-636111 and servss to: cover recessed backboxes n applications. _ - Standard steel backbox provided vAh knockouts for interior surface mounting, concealed conduit mounting or 5em14!ush applications. _ 4 3:: .0 N$-32_/[O 3-3W' ,, 0 ID 00 HOLES 0 () 0 0 Used vtth Series _IAP _____ I 214' I Ml. SET, SE, NH, NS ST Provisions for (4) J-nuts #8-32 lb 3-51e' ?ROVED wlT K1OOKOJT.3—' Square Material: Steel (S) APS ADAPTER PLATE Used with Series Used with Serics ORDERCODE - RED: 500-636109 s AH.AS.BO. 810, HS, MBDC. MH115.MTh.NH,SETSF. ST Stamped alumswm adapter pla:e designed for (X) SHBBS applications where serni-flush installations cannot be used. The plate can be. mounted to standard ORDER or round backboxes single or double gang SQUARE SURFACE BACKBOX CODES - RED: 500-636126, (0) RETROFIT PLATE octagon ORDER CODES -[PENDING] boxes or pteser rings. The backbox and basic wilt WHITE 500-636121 are then fastened to the plate. This type of mounting ,. . I32•• is referred to as'ccncealed conduit instiilation. fw1s_[ J alto —1 - Ire, TAP 49 HOLES 000 148 0 Ll 4 L — Used with Senes Used with Series Used with Series 86. B10,MBOC,MTH,NH,SE as. 810, MBDC AH, AS. NH. ST SIEMENS Industry, Inc. Building Technologies Division (Y) SERS SQUARE SEMI-FLUSH (BB) SPSSB (EE) SPEXT EXTENSION RING EXTENSION RING ORDER CODES- RED: 500-636114, ORDER CODES - RED: 500-636116, ORDER CODES- RED 500-636122, WHITE: 500-636123 WHITE: 500-636115 1UP WHITE: 500-636117 [ I' TOP I f III II I 7.325• 13 DS-_.jj4A I - - - Seriesth Used Used with Series (wall mount speakertstrobe)Used th Series SM-C (Ceiling Mount Strobe) ZJ SBUS BACKBOX (CC) SBLW 8" CEILING SUPPORT BRIDGE (FF) ZBB ORDER CODE- RED: 500-636121 ORDER CODE - WHITE: 500-634882 fr1U16 . I.DlE'k. F'-;: - _______ 23J50 _uYP_ ORDER CODES - RED: 500-636193, WHITE: 500-636194 I —1 ta-ls,t . TYP M_'c' 0 FCt E&AD DLL-_JrL]Q. Used with Series ST Used with Series S 8' Ceiling Speakers Used with Series z____________________ (AA) SPSB (DD) SEA r- J.1JG SPUR (GG) WFPS PLATE (HH) WFPAS PLATE ORDER CODES- RED: 500-636112, WHITE: 500-636113 - r —'"--i ORDER CODES - RED: 500-636135. ORDER CODES - RED: 500-363133, Sol" h--' - WHITE: 500-636136 WHITE: 500-656134 r®ril I2-tltt' I 1jinr 111-4 Used with Series ____ Used with Series Used with Series MTH-WP, STWP Used with Series AS-WP SE -(Speakers) S 8' Ceiling Speakers I SIEMENS Industry, Inc. Building Technologies Division Mounting Matrix 1buS ' Series) 0 0 Ui 0 U, I CU)Cfl(flU) I Ca U)U)U)20U)U)U)u2ZI<zN 000000)00000000000)00 000000000000000000)00 50 W CO - C 'U te Ca Cal I Z < I I- a. I U)(l) I Universal Mounting Plate (included with AS series devices) X 1 -GANG x3-1!2" Deep - Flush (BO) X X X X X 1-GANG x 1-314" Deep - Surface (BO) X 4" x 4" x 1.5" Deep - Flush (BO) X X X X X X X X 4"x 4"x 2.125 Deep - Flush (BO) X X X X X X X X X X X X 2-Gang x 3.5" Deep - Flush (BO) X X X X X X 2-Gang xl .75" Deep - Surface (BO) X X X (I) WPBBS-R Weatherproof Back box for AS-WP 2 (J) BBS Surface (SP) Note 9 X X X X X (K) WBBS Weatherproof (SP) X X X X X 3 (M) MT-SUR-BOX Surface & Weatherproof (SP) X X X 4 (N) DBB5 Surface (SP) X X X X X X X X (0) Retrofit Plate X SBBS Surface (SP) X X X X X X X X X X X 4"x 4" x 2.125" Box wl 1.5" Extension Ring- Flush (BO) X X - X X X X SPT Semi-Flush Plate (SP) - X X - X X X X X X X X X APS Adapter Plate (SP) X X X X (1) WPSBBS-R Weatherproof Back box for ST-WP 1 (U) 5" Square Back box wl Extension Ring. Flush (BO) X X X X 4.6875" x 4.6785" x 2.125" Deep Surface (BO) SHBBS (SP) Shallow Surface X X X X X SERS Semi-Flush Extension Ring (Retrofit Appl.) X X X SBLS-2 Surface (SP) - X X X X X X X - (AA) SPSB Back box for SE Speaker X - (BB) SPSSB Back box for SE & S-HQ Speaker! Strobes X X (CC) SP (EE) SPEXT Extension Ring X (FF) ZBB - - - x (GG) WFPS Plate X -- - - X - - - - - (HH) WFPAS Plate I IX - - SIEMENS Industry, Inc. Building Technologies Division Mounting Notes dCaution: The mounting options figures show the maximum number of field wires (conductors) that can enter the back box used with each mounting option. If these limits are exceeded, there may be insufficient space in the back box to accommodate the field wires and stresses from the wires could damage the product. Although the limits shown for each mounting option comply with the National Electrical code (NEC), Siemens recommends use of the largest back box option and the use of approved field wires whenever possible to provide additional wiring room for easy installation and minimum stress on the product from wiring. £Caution: Check that the installed product will have sufficient clearance and wiring room prior to installing back-boxes and conduit, especially if sheathed multi- conductor cable or 3/4" conduit fittings are used. Mounting hardware for each mounting option is supplied. Conduit entrances to the back box should be selected to provide sufficient wiring clearance for the installed product. When extension rings are required, conduit should enter through the back box, not the extension ring. Use Steel City #53151(1-112" deep) or #53171 (2-1/8" deep) extension rings (as noted in the mounting options) or equal with the same cut- out area. When terminating field wires, do not use more lead length than required. Excess lead length could result in insufficient wiring space for the appliance. SIEMENS Industry, Inc. Building Technologies Division Use care and proper techniques to position the field wires in the back box so that they use minimum space and produce minimum stress on the product. This is especially important for stiff, heavy gauge wires and wires with thick insulation or sheathing. Do not pass additional wires (used for other than the appliance) through the back box "unless the back box is of a sufficient size to permit additional wiring as described in NEC 314.16 (B)". Such additional wires could result in insufficient wiring space for the appliance. Note: Due to continuous development of our products, specifications and offerings are subject to change without notice, in accordance with Siemens Industry, Inc. standard terms and conditions. Back Box Mounting Siemens Wall-Mounted, Horizontal Strobe Appliances NFPA-72 (2007) 7.5.4.1 * —Wall-mounted appliances shall be mounted such that the entire lens is not less than 2030 mm (80 in.) and not greater than 2440 mm (96 in.) above the finished floor or at the mounting height specified using the performance-based alternative 7.5.4.5 7.5.4.2 - Where low ceiling heights do not permit mounting at a minimum of 2030 mm (80 in.), visible appliances shall be mounted within 150 mm (6 in.) of the ceiling. The room size covered by a strobe of a given value shall be reduced by twice the difference between the minimum mounting height of 2030 mm (80 in.) and the actual, lower mounting height. Back box Mounting Options* Series ASIAH Audible Strobe cries ST-MC-RETRO (Flush and Surface Retrofit Plate) Horn Series NS - Strobe Series Z and ST Strobe Series MTH Multi-tone - - 80 IN. GIN. ____ 80 IN. ____ GIN. _____ 80 IN. GIN. 80 IN. _____ GIN. 80 IN. GIN. (B) 1-Gang x 2" Deep - Flush (BO) 77111 8111 78 3/a" 7 51a" 79 'Ia° 6 W (D) 4" x 4" x 1.5" Deep - Flush (BO) 77" 9" 8315116" 77 71a 'is' 78 Ia" 7 Ia" 79 15/" 6 Ilie 6 1i (E) 4"x 4"x 2.125" Deep - Flush (BO) 77" 9" 83'/,a° 77 VIa" 8 'is" 78 sle 7 31a" 79 1S/" 6 ", 6 1i (F) 2-Gang x 3.5" Deep - Flush (BO) 77111 81!1 78 I8" 7 51a" 79 1!a 6 VIa" 80 91le 5 7,s 1 5 (G)2-Gangx 1.75" Deep - Surface (BO) 77'!? 8112" 78 31a" 7 5!a" 79 'Is" 6 !a" 8091,a' 5 ",( 5 ",& (M) MT-SUR-BOX Surface & Weatherproof (SP) - 79 31a" 6 51a" 6 51a" (P) SOBS Surface (SP) 79 1/4" 6 34" 6 34" (U) 5" Square Back box WI Extension Ring. Flush (80) 691/? 81W 83 71,6" 7 7 31s" 7 51a" 78 'Ia" 6 7Ia" 79 I,a" 5 91( 5 gs- (X) SHBBS (SP) Shallow Surface 76'W 9112' 7 7 31a" 8 sle 78 'Ia" 7 71a" (Z) SBL2S Surface (SP) - - 78" (FF) ZBB - - 78 'is" 7 71a" More Back box Series CH Series SET-V Series SEF-C Series SET-C Chime Strobe Speaker Strobe Speaker Strobe Speaker Strobe Mounting Options- 80 IN-76 IN. 80 IN. GIN. 80 IN. GIN. 80 IN. GIN. SBB Surface (SP) 77-314° 8-1/4" 79-3116" 6-13116" 77-3/4" 8-114" 77-314" 8-114° 4" x 4" x 2.125" Box W/ 1.5° 77-112" 7-1/2" 80 6" 78-112" 7-1/2" 78-1/2" 7-112" Extension Flush _Ring _-_ _(BO) (U)5" Square Back box with 78" 7" 79-112" 5-112° 78" 7" 78" 7" Extension Flush (BO) _Ring _- SHBB (SP) Shallow Surface ____ _ (X) __ (Y)4°x4°xl.5°Boxw/1.5" 12" E 7-1I2° 80" 6"Extension-RingPlate - Flush(BO) ____ _ * Measured from Bottom of Back box Notes: (BO) = By Others (SP) = Siemens Product Notice: This marketing catalog sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard SIEMENS Industry, Inc. Florham Park, NJ 07932 Brampton, Ontario Building Technologies Division Tel: (973) 593-2600 (Sill LIST 5E4 I Canada December 2009 FAX: (908) 547-6877 Printed in U.S.A. Tel: (905) 799-9937 sheet dated 7107 URL: www.SBT.Siemens.comlFlS FAX: (905) 799-9858 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0067:0248 Page 1 of I CATEGORY: 7125— FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Siemens Industry, Inc. Building Technologies Division8 Fernwood Road, Florham Park, NJ 07932 Contact: Peter Pawchak (973) 593-2662 Fax (973) 593-6652 Email: Peter.pawchak@siemens.com DESIGN: Models NH-R, NH-W, NH-CR, NH-CW, ZH-R, and ZH-W horns and models NS-MC-R, NS-MC-W, ZH-MC-R, ZH-MC-W, ZH-HMC-R, AND ZH-HMC-W Horns I Strobes. Models NS-MC-CR, NS-MC-CW, NS-HMC-CR, NS-HMC-CW, ZH-MC-CR, ZH-MC-CW, ZH-HMC-CR, ZH-HMC-CW are horn / strobes for ceiling mount only. Suffix CR or CW are for ceiling and color. Units are synchronized or non-synchronized strobes. Refer to Listee's data sheet for additional detailed product description and operational RATING: Electrical 16-33VDC/FWR Candela: NS-MC-C, ZH-MC-C = 15/30/75/95 candela NS-HMC-C, ZH-HMC-C = 115/177 Cd NS-MC, ZH-MC = 15/30/75/110 cd ZH-HMC, = 135 / 185 Cd Flash Rate: 60 flashes / minute INSTALLATION: In accordance with Listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical / candela rating and UL label. APPROVAL: Listed as audible and audible //visual signaling devices for use with separately listed electrically compatible fire control units. Models with strobe lights are suitable for the hearing impaired. For indoor use only. All synchronization strobes shall be used with model DSC sync control module (CSFM listing No. 7300-0067:212). Refer to manufacturer's installation manual for details Note: These appliances can produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: 09-07-2007 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0067:0252 Page 1 of I CATEGORY: 7125— FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Siemens Industry, Inc. Building Technologies Division8 Fernwood Road, Florham Park, NJ 07932 Contact: Peter Pawchak (973) 593-2662 Fax (973) 593-6652 Email: Peter. pawchak©siemens.com DESIGN: Models ST-MC-RETRO-R, ZR-MC-W, ZR-MC-R, ZR-HMC-R, ZR-HMC-W intended for indoor use on walls. Models ST-MC-CW, ST-HMC-CW, ZR-MC-CRZR-MC-CW, ZR-HMC-CR. and ZR-HMC-CW multi candela intended for indoor use mounted on the ceiling only. Z -series strobes are intended for use with models ZB-R or ZB-W back boxes. ST - series strobes are intended for use with models SHBBS surface back boxes. Model numbers may be followed by alpha characters indicating lens orientation, lettering, and color. Refer to listee's data sheet for additional detailed product description and operating,considerations. RATING: Electrical 16-33VDC/FWR Candela: ST-MC-RETRO-R 15cd, 30cd, 75cd, 110cd ZR-MC-W, ZR-MC-R 15cd, 30cd, 75cd, 110cd ZR-MC-CR, ZR-MC-CW 15cd, 30cd, 75cd, 95cd ST-MC-CW lscd, 30cd, 75cd, 95cd ZR-HMC-R, ZR-HMC-W 135/185cd ZR-HMC-CR, ZR-HMC-CW 115/177cd Flash Rate: 60 flashes I minute INSTALLATION: In accordance with Listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Models with suffix -Ware wall mount only. Models with suffix -C are ceiling mount only. All models are for indoor use only. MARKING: Listee's name, model number, electrical I candela rating and UL label. APPROVAL: Listed as strobe light suitable for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's installation instruction manual for details. NOTE: I I I This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct 61 V operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other I Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division I IEC POWER COMMUNICATION SYSTEMS, INC. SALES - SERVICE - ENGINEERING I Public Address • Paging • Intercom Fire Alarm • Nurse Call • CCTV I U WARRANTY PowerCommunication Systems, Inc. warrants its work and/or material supplied to- be in substantial I compliance with plans and specifications set forth. Material purchased from, and installed by PowerCOmmunication Systems, Inc., is wárraAted to be free from defects in material or workmanship for a period of one year from date of acceptance, or first I beneficial usage, whichever occurs first. - The undersigned does hereby agree to repair or replace at their own expense, during normal working I I hours, any equipment or workmanship provided and installed by them found to be defective. I They also agree to repair or replace at their discretion any materials sold by them and installed by others for a period of one year from date of sale. This is an over-the-counter warranty and is limited to materials returned to them with proof of purchase. This warranty shall not apply to any material sold or installed by Power Communication Systems, Inc. which has been subject to abuse, misuse, neglect, accident, or use contrary to instructions furnished. All requests for warranty service must be accompanied by a valid Purchase Order and "Bill To" address. When applicable, invoices for warranty work will indicate "No Charge". In the event the undersigned fails to comply with the above within a 30 day period after official written notification of failure or defect, the owner shall have the right to repair it at their discretion at Power Communication Systems expense. POWER COMMUNICATION SYSTEMS, INC. - 1 Ernest Power Ill Date P.O. Box 600066, San Diego, CA 92160-0066 4627-A Mission Gorge Place, San Diego, CA 92120-4133 (619) 583-7400 • Fax: (619) 583-0647 License No. 636431-C7/C10