Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2035 CALETA CT; ; AS150191; Permit
City of Carlsbad Sprinkler Permit F' Permit No: AS.150191 Job Address: 2035 CALETA CT Status: ISSUED Permit.Type: SPRINK Applied 6/26/2015 Parcel No: 2151107900 Approved: 6/30/2015 Lot #: 0 • • Reference No.: • Issued: 6/30/2015 PC #: • Inspector: Project Title: GILLEY RESIDENCE SFR Applicant: Owner: • SYMONS FIRE-PROTECTION WOLF EMANUEL L TRUST 01-16-02 SUITE • 1050 PIONEER WAY • 2035 CALETA CT EL CAJONI CA • • CARLSBAD CA 619-588-6364 Fees ($) Add'I Fees ($) Total ($) Balance ($) 210 0 • 210 •. • 0 SYMONS FIRE PROTECTION, INC. 1050 PIONEER WAY, SUITE R EL CAJON, CA 92020 LICENSE C16-682025 HYDRAULIC CALCULATIONS FOR GILLEY RESIDENCE REMOTE AREA 2 HEAD CALC TYCO LF II CONC/FLAT These plans have been reviewed 111- anparenl coutipliance Willi the current applicable cntk and standard iii force in the juridictiuun. The owner or contr;tcuor may uiilic hOn, review in support nI an application for a building perth with the express undi:rsuanding that this review In iii way rchv-.;:s I he owner or conl raclor or their iii I.sion;ui euueiuucer or aivhiteci for sole responihihiuv lw lull uuiuupl lance wi lb said codes and standards. uuuchuidinui the building code or for any repuunsihilcv For deficiencies. errors. omissions or negligence in these plans whether or not noted in this review. I )ate: ç Reviewer-A/ Lai KhC(MIMENl) APPROVAl. El l(EC()MMENI) APPROVAL. AS NOTED FILE NUMBER: 15-206 DATE: 5-31-15 -DESIGN DATA- OCCUPANCY CLASSIFICATION: R3 DENSITY: AREA OF APPLICATION: NUMBER OF SPRINKLERS CALCULATED: TOTAL SPRINKLER WATER FLOW REQUIRED: TOTAL WATER REQUIRED (including hose): FLOW AND PRESSURE (@ NODE 5 BOR): SPRINKLER K-FACTOR (ORIFICE SIZE): DESIGN/LAYOUT BY: AUTHORITY HAVING JURISDICTION: WATER FLOW AVAILABILITY DATA: STATIC: RESIDUAL: FLOW: WATER DEPARTMENT: .05 gpm/256 sq. ft. 512 sq. ft. 2 sprinklers 26.0 gpm 31.0 gpm (5 gpm Hose STREAM) 26.0 gpm @ 25.6 psi 4.9 CANDI CAUDILLO CARLSBAD FIRE DEPT. 99 psi (-10% 89PSI) 98 psi 500 gpm CARLSBAD WATER 5-21-15 CALCULATIONS BY HASS COMPUTER PROGRAM HRS SYSTEMS, INC. FLT ECOPY ATLANTA, GA AS 150191 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 6/1/2015 C:\PROGRAN FILES\HRS SYSTEMS\HASS83\15-206.SDF JOB TITLE: GILLEY RESIDENCE - 2 HEAD CALC. WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 89.0 88.0 500.0 89.0 31.0 50.0 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 31.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 0.0 SOURCE 50.0 31.0 2 3.0 - - - - 41.4 - - - 3 3.0 - - - - 37.4 4 5.0 - - - - 32.6 5 9.0 HOSE STREAM 25.6 5.0 6 15.0 ---- 21.6 7 15.0 - - - - 17.4 - - - 8 15.0 - - - - 14.7 - - - 9 18.0 - - - - 9.3 - - - 10 18.0 - - - - 12.7 11 18.0 K= 4.90 7.0 13.0 12 18.0 K= 4.90 7.0 13.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 6/1/2015 C:\PROGRAM FILES\HRS SYSTEMS\HASS83\15-206.SDF JOB TITLE: GILLEY RESIDENCE - 2 HEAD CALC. PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 31.0 0.995 PL 20.00 PF 7.3 1 0.0 SRCE 50.0 (N/A) 12.8 150 FTG TG PE -1.3 2 3.0 0.0 41.4 0.0 0.251 TL 29.00 PV Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 3.0 0.0 41.4 0.0 4.0 psi, 31.0 gpm 3 3.0 0.0 37.4 0.0 Pipe: 3 31.0 1.101 PL 25.00 PF 4.0 3 3.0 0.0 37.4 0.0 10.4 150 FTG 1.0 PE -0.9 4 5.0 0.0 32.6 0.0 0.153 TL 26.00 PV Pipe: 4 31.0 1.025 PL 5.00 PF 5.2 4 5.0 0.0 32.6 0.0 12.1 150 FTG 19.0 PE -1.7 5 9.0 H.S. 25.6 5.0 0.217 TL 24.00 PV Pipe: 5 . 26.0 1.101 FL 6.00 PF 1.4 5 9.0 H.S. 25.6 5.0 8.8 150 FTG 7.0 PE -2.6 6 15.0 0.0 21.6 0.0 0.111 TL 13.00 PV Pipe: 6 26.0 1.101 FL 15.00 PF 4.2 6 15.0 0.0 21.6 0.0 8.8 150 FTG 23.0 FE 0.0 7 15.0 0.0 17.4 0.0 0.111 TL 38.00 PV Pipe: 7 13.5 1.101 PL 57.00 PF 3.4 7 15.0 0.0 17.4 0.0 4.6 150 FTG 47.0 FE -1.3 10 18.0 0.0 12.7 0.0 0.033 TL 104.00 PV Pipe: 8 13.5 1.101 FL 90.00 PF 5.6 10 18.0 0.0 12.7 0.0 4.6 150 FTG 81.0 FE 0.0 11 18.0 4.9 7.0 13.0 0.033 TL 171.00 PV Pipe: 9 0.5 1.101 FL 23.00 PF 0.0 11 18.0 4.9 7.0 13.0 0.2 150 FTG 27.0 FE 0.0 12 18.0 4.9 7.0 13.0 0.000 TL 50.00 PV Pipe: 10 12.5 1.101 FL 63.00 PF 2.8 7 15.0 0.0 17.4 0.0 4.2 150 FTG 34.0 FE 0.0 8 15.0 0.0 14.7 0.0 0.028 TL 97.00 PV Pipe: 11 12.5 1.101 PL 97.00 PF 4.1 8 15.0 0.0 14.7 0.0 4.2 150 FTG 46.0 FE -1.3 9 18.0 0.0. 9.3 0.0 0.028 TL 143.00 PV Pipe: 12 12.5 1.101 PL 50.00 PF 2.2 9 18.0 0.0 9.3 0.0 4.2 150 FTG 29.0 FE 0.0 12 18.0 4.9 7.0 13.0 0.028 TL 79.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 6/1/2015 C:\PROGRAM FILES\HRS SYSTEMS\HASS83\15-206.SDF JOB TITLE: GILLEY RESIDENCE - 2 HEAD CALC. NOTES (HASS): Calculations were performed by the HASS 8.4 computer program under license no. 38071930 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.011 gpm and a maximum imbalance at any node of 0.116 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 12.8 ft/sec at pipe 1. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. Available pressure at source node 1 under full flow conditions is - 88.99 psi compared to the minimum required pressure of 20.00 psi. PIPE FITTINGS TABLE Pipe Table Name: FSS.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEii ChkVlv BfyVlv GatViv AlmChk DPVlv NPTee 1.101 2.53 6.33 2.53 6.33 7.59 1.27 12.66 12.66 6.33 PAGE: H MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T R K C L B L Eli Tee TEERUN COUPLG EL45 1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00 PAGE: I MATERIAL: CPPR-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C. B G A D Eli Tee 1.025 3.00 8.00 2.00 8.00 2.00 2.00 0.00 0.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 6/1/2015 C:\PROGRAM FILES\HRS SYSTEMS\HASS83\15-206.SDF JOB TITLE: GILLEY RESIDENCE - 2 HEAD CALC. PAGE: K MATERIAL: CPPR-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee L 0.995 2.00 6.00 1.50 0.00 0.00 3.00 0.00 0.00 1000 WATER SUPPLY ANALYSIS 100. 0 1 G 80.0 A U G E 60.0 R E S 2 S 40.0 p S i 20.0 -14. LLL(..; o.uu L'.ej.u; oo.uv pb.L r.Luw; JUV.V gpm LEGEND 1 Available pressure 88.99 psi @ 31.0 gpm 2 --- -Required pressure - - - 50.01 psi 8 31.0 gpm Source Supply Curve System Demand Curve 0U iOU 400 500 600 700 800 900 FLOW (GPM) (Note: Dashed Lines indicate extrapolated values from Test Results) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 6/1/2015 C:\PROGRAM FILES\HRS SYSTEMS\HASS83\15-206.SDF JOB TITLE: GILLEY RESIDENCE - 2 HEAD CALC. WATER SUPPLY CURVE 96+ 880 * <-88.0 psi @ 500 gpin I Flow Test Point 80+ 72+ P 64+ R I E! I S I 5 56+ R I E X 48+ ( I P I S I I 40+ ) I 32+ 24+ 16+ LEGEND I 'I I X = Required Water Supply I 50.01 psi @ 31.0 gpm 8+ I 0 = Available Water Supply " 88.99 psi @ 31.0 gpm 0++-+---+----+-----+------+--------+--------+---------+-----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) tqca Ffre Protection Products Worldwide w.ico-fire.com Contacts RAPID RESPONSE Series LFII Residential 49 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and Dry Pipe Systems General Description TYCO RAPID RESPONSE Series LFII Residential 4.9K Concealed Pendent Sprinklers (TY3596) are decorative, fast response, fusible solder sprinklers designed for use in residential occu- pancies such as homes, apartments, dormitories, and hotels. The cover plate assembly conceals the sprinkler operating components above the ceiling. The flat profile of the cover plate provides the optimum aes- thetically appealing sprinkler design. In addition, the concealed design of the Series LFII Residential Concealed Pendent Sprinklers (TY3596) provides 1/2 inch (12,7 mm) vertical adjustment. This adjustment provides a measure of flexibility when cutting fixed sprinkler drops. The Series LFII Residential Concealed Sprinklers are intended for use in the following scenarios: wet and dry pipe residential sprin- kler systems for one- and two-fam- ily dwellings and mobile homes per NFPA 13D wet and dry pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 The Series LFII Residential Concealed Pendent Sprinklers (TY3596) has been designed with heat sensitivity and water distribution characteristics proven to help in the control of residen- tial fires and to improve the chance for occupants to escape or be evacuated. The Series LFII Residential Con- cealed Pendent Sprinklers (TY3596) are shipped with a Disposable Pro- tective Cap. The Protective Cap is temporarily removed for installation, and then it can be replaced to help protect the sprinkler while the ceiling is being installed or finished. The tip of the Protective Cap can also be used to mark the center of the ceiling hole into plaster board, ceiling tiles, etc. by gently pushing the ceiling product against the Protective Cap. When the ceiling installation is complete the Pro- tective Cap is removed and the Cover Plate Assembly installed. Dry Pipe System Application The Series LFII Residential Concealed Pendent Sprinklers offers a laboratory approved option for designing dry pipe residential sprinkler systems, whereas, most residential sprinklers are labora- tory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Concealed Pendent Sprinklers (TY3596) need not be increased over the number of design sprinklers (hydraulic design area) as specified for wet pipe sprinkler systems, as is accustomed for density/ area sprinkler systems designed per NFPA 13. Consequently, the Series LFII Residen- tial Concealed Pendent Sprinklers offer the features of non-water filled pipe in addition to not having to increase the number of design sprinklers (hydraulic design area) for systems designed to NFPA 13,13D, or 13R. FEBRUARY 2015 NOTICE The Series LFII Residential Concealed Pendent Sprinklers (TY3596) described herein must be installed and main- tained in compliance with this docu- ment and with the applicable standards of the National Fire Protection Associa- tion (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the perfor- mance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY3596 TFP442 THREAD INTO SUPPORT CUP UNTIL MOUNTING SURFACE IS FLUSH WITH CEILING SOLDER TAB ASSEMBLY FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER (TY3596) DEFLECTOR IN TFP442 Page 2 of 6 WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 2 W-TYPE 18 SPRINKLER WRENCH BODY SEALING (1/2'NP1)-..__ _- ASSEMBLY r4ro- T q• SUPPORT COMPRESSION CUP WITH E]z SCREW ROLL FORMED THREADS LEVER GUIDE PIN SOLDER LINK ELEMENT GUIDE PIN HOUSING DEFLECTOR (OPERATED POSITION) OSITION) SPRINKLER/SUPPORT CUP ASSEMBLY 2-1/2 DIA. - (63,5 mm) 1/2' (12,7 mm) FACE OF THREADED SPRINKLER N ADJUSTMENT FITTING 1 1-7/8±1/4' F- (47,6 mm 1/8 GAP I ±6,4 mm) '(3,2 mm) I COVER- SPRINKLER- MOUNTING RETAINER SUPPORT CUP 3/16" SURFACE ASSEMBLY ASSEMBLY (4,8 mm) 3-3/16" DIA. RETAINER WITH THREAD .- DIMPLES EJECTION SPRING - COVER PLATE SPRINKLER- SUPPORT CUP / ASSEMBLY OPERATED SPRINKLER COVER PLATE .-._. - RETAINER -a L- I'm 7/8" (22,2 mm) \ 1-1/8(28,6mm) DISPOSABLE (81,0 mm) TIP PROTECTIVE CAP OPERATED POSITION FIGURE 3 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER (TY3596) INSTALLATION DIMENSIONS/PROTECTIVE CAP/ACTIVATED DEFLECTOR TFP442 Page 3 of 6 Technical Data Approvals UL and C-UL Listed NYC Approved under MEA 44-03-E-2NSF Certified to NSF/ANSI 61 The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers are only Listed with the Series LFII Con-cealed Cover Plates having a factory-ap- plied finish. Cover Plates can be ordered by following the instructions in the Ordering Procedure section. Maximum Working Pressure 175 psi (12,1 bar) Discharge C&fficient K=4.9 gpm/psi (70,6 (pm/bar112) Temperature Rating 160°F (71°C) Sprinkler with 139°F (59°C) Cover Plate Vertical Adjustment 1/2 inch (12,7 mm) Finishes Refer to Ordering Procedure section. Physical Characteristics Body.........................Brass Cap.........................Bronze Saddle .......................Brass Sealing Assembly.......Beryllium Nickel w/TEFLON Soldered Link Halves............Nickel Lever........................Bronze Compression Screw.............Brass Deflector...................Copper or Brass Guide Pin Housing.............Bronze Guide Pins .............Stainless Steel or Bronze ..............Steel ............Copper Retainer ...................... Stainless Steel Operation When exposed to heat from a fire, the Cover Plate, which is normally soldered to the Support Cup at three points, falls away to expose the sprinkler assembly. At this point the Deflector supported by the Arms drops down to its operated position. The fusible link of the sprin- kler assembly is comprised of two link halves that are soldered together with a thin layer of solder. When the rated temperature is reached, the solder melts and the two link halves separate allowing the sprinkler to activate and flow water. Design Criteria TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprin- klers (TY3596) are UL and C-UL Listed for installation in accordance with this section. Note: When conditions exist that are outside the scope of the provided cri- teria, refer to the Residential Sprinkler Design Guide TFP490 for the manu- facturer's recommendations that may be acceptable to the authority having jurisdiction. System Types Per the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet TFP485 about the use of residential sprinklers in residential dry pipe systems. Ceiling Types Smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13 as applicable. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum required sprinkler flow rates are given in Tables A and B as a function of tem- perature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. The number of "design sprinklers" specified in NFPA 13D and 13R for wet pipe systems is to be applied when designing dry pipe systems. Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: the flow rates given in Tables A and B as a function of temperature rat- ing and the maximum allowable cov- erage area a minimum discharge of 0.1 gpm/ft.2 over the design area comprised of the four (4) most hydraulically demanding sprinklers for actual coverage areas protected by the four (4) sprinklers The number of design sprinklers speci- fied in NFPA 13 for wet pipe systems is to be applied when designing dry pipe systems. Dry Pipe System Water Delivery When using the Series LFII Residen- tial Concealed Pendent Sprinklers (TY3596) in dry pipe sprinkler systems, the time for water delivery must not. exceed 15 seconds for the most remote operating sprinkler. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational Sensitivity The sprinklers are to be installed rela- tive to the ceiling mounting surface as shown in Figure 3. Sprinkler Spacing The minimum spacing between sprin- klers is 8 feet (2,4 m). The maximum spacing between sprinklers cannot exceed the length of the coverage area (Ref. Table A or B) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). The Series LFII must not be used in applications where the air pres- sure above the ceiling is greater than that below. Down drafts through the Support Cup could delay sprinkler operation in a fire situation. Support Cup Cover Plate Cover Plate Ejection Spring P.. TFP442 Page 4 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure 2.3 Maximum Maximum Coverage Area I Spacing Ordinary Temp. Rating 160°F (71°C) Minimum Ft x Ft Ft. (m) Deflector to Installation Spacing Flow Pressure (rn x m) Ceiling Type Ft. gpm psi (m) (1pm) (bar) 12x12 12 13 7.0 Smooth (3.7 X 3,7) (3,7) (49,2) (0.48) ceilings 7/8 to 1-1/8 14x14 14 .13 7.0 inches (4,3x4,3) (4,3) (49.2) (0,48) Beamed Ceilings per NFPA 13D or Concealed 13R, 8 (2,4) 16 x 16 (4,9x4,9) 16 (4,9) 13 (49,2) 7.0 (0,48) or 13. Installed in 18x18 18 17 12.0 beam (5,5x5,5) (5,5) (64,3) (0,83) 7/8to1-1/8 inches below bottom of 20 x 20 20 20 16.7 (6,1 x 6,1) (6,1) (75,7) (1,15) beam Notes: For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in gpm Opm) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm/ft.' over the design area or the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENT SPRINKLER (TY3596) NFPA 130, 13R, AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Minimum Flow and Residual Pressure 2.3 Maximum Coverage Maximum Spacing Ordinary Temp. Rating Minimum Area 1 160°F (71°C) Ft. x Ft. Ft. Deflector to Installation Spacing Flow Pressure (mxm) (m) Ceiling Type Ft. gpm psi (m) Opm) (bar) 12x12 12 13 7.0 Smooth (3,7 X 3,7) (3,7) (49.2) (0,48) Ceilings 7/8 to 1-1/8 14 x 14 14 14 8.2 inches (4,3x4,3) (4,3) (53.0) (0,57) Beamed Ceilings per NFPA 13D or Concealed 13R, 8 (2,4) 16 x 16 (4,9x4,9) 16 (4,9) 15 (56,8) 9.4 (0,65) or 13. Installed in 18x18 18 18 13.5 beam (5,5x5,5) (5,5) (68,1) (0.93) 7/8to1-1/8 inches below bottom of 20 x 20 20 21 18.4 (6,1 x 6,1) (6,1) (79.5) (1,27) beam Notes: For coverage area dimensions less than or between those Indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are slated. Requirement Is based on minimum flow in gpm Opm) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm/ft.° over the design area or the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM RAPID RESPONSE SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENT (TY3596) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA TFP442 Page 5 of 6 Installation TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprin- klers (TY3596) must be installed in accordance with this section. General Instructions Damage to the fusible Link Assembly during installation can be avoided by handling the sprinkler by the support cup only (i.e., do not apply pressure to the fusible Link Assembly). A 1/2 inch NPT sprinkler joint should be obtained with a minimum to maximum torque of 7 to 14 lbs.-ft. (9,5 to 19,0 Nm). Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Cover Plate / Retainer Assembly by under- or over-tightening the Sprinkler. Read- just the position of the sprinkler fitting to suit. Step 1. The sprinkler must only be installed in the pendent position and with the centerline of the sprinkler per- pendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant applied to the pipe threads, and using the W-Type 18 Wrench shown in Figure 2, install and tighten the Sprinkler / Support Cup Assembly into the fitting. The W-Type 18 Wrench will accept a 1/2 inch ratchet drive. Step 4. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. The Protec- tive Cap helps prevent damage to the Deflector and Guide Pins during ceiling installation and/or during application of the finish coating of the ceiling. It may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Cap. Note: As long as the protective Cap remains in place, the system is consid- ered to be "Out Of Service." Step S. After the ceiling has been completed with the 2-1/2 inch (63 mm) diameter clearance hole and in prep- aration for installing the Cover Plate Assembly, remove and discard the Pro- tective Cap, and verify that the Deflec- tor moves up and down freely. If the sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire sprinkler assembly. Do not attempt to modify or repair a damaged sprinkler. Step 6. Screw on the Cover Plate Assembly until its flange comes in contact with the ceiling. Do not continue to screw on the Cover Plate Assembly such that it lifts a ceiling panel out of its normal position. If the Cover Plate Assembly cannot be engaged with the Mounting Cup or the Cover Plate Assembly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. Care and Maintenance TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprin- klers (TY3596) must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of a Cover Plate may delay the sprinkler operation in a fire situation. When properly installed, there is a nominal 1/8 inch (3,2 mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 3. This air gap is necessary for proper opera- tion of the sprinkler by allowing heat flow from a fire to pass below and above the Cover Plate to help assure appropriate release of the Cover Plate in a fire situation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted units. Non-factory applied paint may adversely delay or prevent sprinkler operation in the event of a fire. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied or over heated sprinklers must be replaced. Care must be exercised to avoid damage before, during, and after instal- lation. Sprinklers damaged by drop- ping, striking, wrench twist/slippage, or the like, must be replaced. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. TFP442 Page 6 of 6 Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and part number (PIN). Sprinkler Assemblies Specify: Series LFll (TY3596) 4.91< Residential Concealed Pendent Sprin- kler without Cover Plate Assembly, P/N 51-112-1-160 Cover Plate Assemblies Specify: Cover Plate Assembly with (specify) finish for the Series LFII (TY3596) 4.91< Residential Concealed Pendent Sprinkler, P/N (specify): Ivory (RAL1015) ...........P/N 56-202-0-135 Beige (RAL1001) ........... P/N 56-202-2-135 Pure WhiteS (RAL9010) .....P/N 56-202-3-135 Signal White (RAL9003) ... P/N 56-202-4-135 Grey White (RAL9002) ......P/N 56-202-5-135 Brown (RAL8028) .......... P/N 56-202-6-135 Black (RAL9005) ..........P/N 56-202-7-135 Brushed Brass............P/N 56-202-8-135 Brushed Chrome ..........P/N 56-202-9-135 Custom Paint .............P/N 56-202-X-135 Eastern Hemisphere sales only Previously known as Bright White Note: All Custom Cover Plates are painted using Sherwin Williams Interior Latex Paint. Contact Tyco Customer Service with any questions related to custom orders. Sprinkler Wrench Specify: W-Type 18 Sprinkler Wrench, PIN 56-000-1-265 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Copyright @2015 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark of The DuPont Corporation. Fire Protection Products tq tection Products Worldwide www.tyco-fire.com Contacts RAPID RESPONSE Series LFII Residential 49 K-factor Pendent Sprinkler Wet Pipe and Dry Pipe Systems General Description TYCO RAPID RESPONSE Series LFII Residential 4.9K Pendent and Recessed Pendent Sprinklers (TY2234) are decorative, fast response, frangi- ble bulb sprinklers designed for use in residential occupancies such as homes, apartments, dormitories, and hotels. When aesthetics and optimized flow characteristics are the major con- sideration, the Series LFII Residential Sprinklers (TY2234) should be the first choice. The Series LFII Residential Sprinklers are intended for use in the following scenarios: wet and dry pipe residential sprin- kler systems for one- and two-fam- ily dwellings and mobile homes per NFPA 13D wet and dry pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 The recessed version of the Series LFII Residential Sprinklers is intended for use in areas with finished ceilings. It employs a two-piece Style 20 Recessed Escutcheon. The Recessed Escutcheon provides 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush ceiling position. The IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 adjustment provided by the Recessed Escutcheon reduces the accuracy to which the pipe drops to the sprinklers must be cut. The Series LFII Residential Sprinklers have been designed with heat sensi- tivity and water distribution charac- teristics proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application The Series LFII Residential Pendent and Recessed Pendent Sprinklers offers a laboratory approved option for designing dry pipe residential sprin- kler systems, whereas, most residential sprinklers are laboratory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) need not be increased over the number of design sprinklers (hydraulic design area) as specified for wet pipe sprinkler systems, as is accustomed for density/ area sprinkler systems designed per NFPA 13. Consequently, the Series LFII Resi- dential Sprinklers offer the features of non-water filled pipe in addition to not having to increase the number of design sprinklers (hydraulic design area) for systems designed to NFPA 13,13D, or 13R. NOTICE The Series LFII Residential Pendent and Recessed Pendent Sprinklers ('TV2234) described herein must be installed and maintained in compliance with this document and the applicable standards of the National Fire Protec- tion Association (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. MARCH 2015 Sprinkler Identification Number (SIN) TY2234 Technical Data Approvals UL Listed (for use with wet pipe and dry pipe sys- tems) C-UL Listed (for use only with wet pipe systems) Certified to all requirements of NSF/ANSI 61 (Refer to the Design Criteria section for de- tails on these approvals.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K=4.9 gpm/psi"2 (70,6 1pm/barl'2) Temperature Rating 155°F (68°C) or 175°F (79°C) Finishes Natural Brass, Pure White, Signal White, or Chrome Plated Physical Characteristics Frame ........................Brass Button ......................Copper Sealing Assembly ......Beryllium Nickel w/TEFLON Bulb (3 mm)...................Glass Compression Screw ............Bronze Deflector .....................Bronze TFP400 TFP400 Page 2 of 6 7/16° (11,1 mm) 1/2' ESCUTCHEON Components: NOMINAL NPT PLATE SEATING 2-7/8" DIA.________ 1 - Frame MAKE-IN SURFACE (73,0 mm) 2 - Button 4-Bulb 5 - Compression 2 2-1/4° Screw 3 - Sealing Assembly 1 ESCUTCHEON \1 1-5/8" 6- Deflector* ' \:::::/.:cdll (57,2 mm) 7FLATS STYLE 20 (41,3mm) I RECESSED WRENCH Temperature rating is 6* indicated on Deflector. CROSS SECTION PENDENT RECESSED PENDENT FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL 4.9K PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) Design Criteria The TYCO RAPID RESPONSE Series LFII Residential 4.9K Pendent and Recessed Pendent Sprinklers are UL and C-UL Listed for installation in accordance with this section. Residential Sprinkler Design Guide When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufactur- er's recommendations that may be acceptable to the local authority having jurisdiction. WRENCH RECESS / ND "A" USED FOR TY2234) FIGURE 3 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH System Types Per the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet TFP485 for the use of residential sprinklers in residential dry pipe systems. Ceiling Types Smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13, as applicable. 2-7/8" DIA. 7/16±1/8" (73,0 mm) I 1/2"(12.7 mm) (11,1±3,2 mm) 2-1/4" DIA. I 1/4"(6,4 mm) I FACE OF (57,2 mm) MOUNTING FITTING PLATE PLATE MOUNTING 7(31/8SURFACE/ ,9 mm) m) CLOSURE TY2234 1-1/8" (28,6 mm) FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE RAPID RESPONSE SERIES LFII RESIDENTIAL PENDENT SPRINKLER Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and flow water. TFP400 Page 3 of 6 Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum required sprinkler flow rates are given in Tables A and B as a function of tem- perature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. The number of "design sprinklers" specified in NFPA 130 and 13R for wet pipe systems is to be applied when designing dry pipe systems. Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: The flow rates given in Table A or B as a function of temperature rating and the maximum allowable coverage area. A minimum discharge of 0.1 gpm/ft2 over the "design area" comprised of the four most hydraulically demanding sprinklers for actual coverage areas protected by the four sprinklers. The number of design sprinklers speci- fied in NFPA 13 for wet pipe systems is to be applied when designing dry pipe systems. Dry Pipe System Water Delivery When using the Series LFII Residential Sprinklers (TY2234) in dry pipe sprin- kler systems, the time for water deliv- ery must not exceed 15 seconds for the most remote operating sprinkler. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational Sensitivity Sprinklers are to be installed with a deflector-to-ceiling distance of 1-1/4 to 4 inches. Sprinkler Spacing The minimum spacing between sprin- klers is 8 feet (2,4 m). The maximum spacing between sprinklers cannot exceed the length of the coverage area (Table A or B) being hydraulically cal- culated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). Installation TYCO RAPID RESPONSE Series LFII Residential 4.9K Pendent and Recessed Pendent Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm). A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum-to-maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutch- eon Plate by under- or over- tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series LFII Residential Pendent Sprinklers The Series LFII Residential Pendent Sprinklers must be installed in accor- dance with the following instructions: Step 1. Install pendent sprinklers in the pendent position with the deflector par- allel to the ceiling. Step 2. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 3). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Series LFIl Residential Recessed Pendent Sprinklers The Series LFII Residential Recessed Pendent Sprinklers must be installed in accordance with the following instructions: Step A. Install recessed pendent sprin- klers in the pendent position with the deflector parallel to the ceiling. Step B. After installing the Style 20 Mounting Plate over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 4). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step D. After the ceiling has been installed or the finish coat has been applied, slide on the Style 20 Closure over the Series LFII Residential Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFP400 Page 4 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure (2)(3) Maximum CoveraQe Ordinary Temperature Rating Intermediate Temperature Rating Minimum Area (J 155°F (68°C) 175°F (79°C) Deflector to Installation Spacing Flow Pressure Flow Pressure Ft. x Ft. Ceiling Type Ft. (m x m) gpm psi gpm psi (m) (I/mm) (bar) (I/mm) (bar) 12 x 12 13 7.0 13 7.0 Smooth (3,7 x 3,7) (49,2) (0,48) (49,2) (0.48) Ceilings 1-1/4 to 4inches Beamed Recessed using Style 20 14x14 (4.3 x 4,3) 13 (49,2) 7.0 (0,48) 13 (49,2) 7.0 (0,48) 16 x 16 13 7.0 13 7.0 Ceilings per Escutcheon or 8 (4,9 x 4,9) (49,2) (0,48) (49,2) (0,48) NFPA 13D or 13R 11/4t013/4 non-recessed per NFPA 130, 13R, or 13 (2.4) 18 x 18 17 12.0 17 12.0 (5,5x5,5) (64,3) (0,83) (64,3) (0,83) inches below bottom of 20 x 20 20 16.7 20 16.7 (6,1 x 6,1) (75,7) (1,15) (75,7) (1,15) beam. Notes: For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in gpm ppm) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpmlft.2 over the design area or the flow In accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9K PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) NFPA 130, 13R, AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Minimum Flow and Residual Pressure (2)(3) Maximum Coveraae Ordinary Temperature Rating Intermediate Temperature Rating Area (I 155°F (68°C) 175°F (79°C) Minimum Ft. x Ft. Deflector to Installation Spacing Flow Pressure Flow Pressure Ceiling Type Ft. (mxm) gpm psi gpm psi (m) (I/mm) (bar) (I/mm) (bar) 12x12 13 TO 13 7.0 Smooth (3,7 x 3,7) (49,2) (0,48) (49,2) (0.48) Ceilings 1-1/4 to 4 14 X 14 (4,3 x 4,3) 14 (53,0) 8.2 (0,57) 14 (53,0) 8.2 (0,57) inches Beamed Recessed using Style 20 16 x 16 15 9.4 15 94 Ceilings Escutcheon or 8 (4,9 x 4,9) (56,8) (0,65) (56,8) (0,65) per NFPA 13D 13R or non-recessed per NFPA 130, p (2,4) 18 x 18 (5,5 x 5,5) 18 (68,1) 13.5 (0,93) 18 (68,1) 13.5 (0,93) 1-1/4 to 1-3/4 13R, or 13 inches below bottom of 20 x 20 21 18.4 21 18.4 (6,1 x 6.1) (79,5) (1.27) (79,5) (1.27) beam. Notes: For coverage area dimensions less than or between those indicated, use the minimum required flow for the nest highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in gpm (lpmj from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpmlft.2 over the design area or the flow In accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9K PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA TFP400 Page 5 of 6 Care and Limited Maintenance Warranty TYCO RAPID RESPONSE Series For warranty terms and conditions, visit LFll Residential 4.9K Pendent and www.tyco-fire.com. Recessed Pendent Sprinklers must be maintained and serviced in accordance with this section: Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installa- tion section). The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any authorities having jurisdiction. Contact the installing con- tractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and part number (P/N). Sprinkler Assemblies Specify: Series LFlI 4.91K Residential Pendent Sprinkler (TY2234), (specify temperature rating), with (specify) finish, P/N (specify): 155°F (68°C) Natural Brass .............. P/N 51-201-1-155 Pure White (RAL 9010)° ......P/N 51-201-3-155 Signal White (RAL 9003) .....PIN 51-201-4-155 Chrome Plated ............. P/N 51-201-9-155 175°F (79°C) Natural Brass..............P/N 51-201-1-175 Pure White (RAL 9010). ...... P/N 51-201-3-175 Signal White (RAL 9003) .....PIN 51-201-4-175 Chrome Plated ............. P/N 51-201-9-175 Eastern Hemisphere sales only Recessed Escutcheon Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) Refer to Technical Data Sheet TFP770. Sprinkler Wrenches Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 TFP400 Page 6 of 6 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Copyright © 2015 Tyco Fire Products, LP. All rights reserved. t co TEFLON is trademark of the Dupont Corporation. 'Fire Protectic,, Products Page 1 of 6 MICROFAST® QUICK lWII[iUI7V RESPONSE PENDENT N111aI1G SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESCRIPTION The Viking Microfese Quick Response Pendent Sprinkler VK302 is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester, Polytetratluoroethelyne (PTFE), and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves ENT finish as corrosion resistant. FM Global has no approval classification for PTFE and Polyester coatings as corro- sion resistant.) LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class Series 2000 nVdS VdS Approved: Certificates G414009 and G414010 LPCB Approved CE CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. Viking Technical Data may be found on The Viking Corporation's Web site at Specifications: http:IIwww.vikinggroupinc.com. Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure The Web site may include a more recent Factory tested hydrostatically to 500 psi (34.5 bar) edition of this Technical Data Page. Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 "F (-55 "C) Overall Length: 2-1/4" (58 mm) cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051 000 or Copper UN S-Cl 9500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-Cll000 and Stainless Steel UNS-S30400 For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, Black PTFE = N, and ENT = JN Temperature Suffix: 135 "F (68 "C) = A, 155 "F (68 "C) = B, 175 °F (79 "C) = D, 200 °F (93 °C) = E, 286 °F (141 "C) = G For example, sprinkler VK302 with a Brass finish and a 155 °F (68 "C) temperature rating = Part No. 12979AB Form No. F_033314 Rev 15.1 (Added CCCF Approval) TECHNICAL DATA Protective Sprinkler - Clip . Flat ;prinkler Page 2 of 6 MICROFAST® QUICK N11a I:lI[u.7MA RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for Recessed Pendent Sprinklers: Part No. 16036W/B** (available since 2011) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) "A 1/2w ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5 . OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast9 Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Figure 1: Standard Sprinkler Wrench 10896W/B Form No. F_033314 Rev 15.1 Page 3 of 6 MICROFAST® QUICK l:llIiu.7aIfa RESPONSE PENDENT I%I II(IF1 SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES '' Classification - : . ' 'Fi •'•-.' .:-;.s•-'-c.-...-..Bulb.Color Tmperature Ratingi ,, CeiIing Temperaturej .- Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 ¶ (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, Black PTFE, and ENT Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 C) Footnotes I The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, PTFE, and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated Sprinkler wrench It for recessed pe sprinklers -- A 112" ratchet is (not available fron Carefully slide the wrench sideways around the protective cap, ensuring engagement wit the sprinkler wrench flats Figure 2: Wrench 16036W18 for Recessed Pendent Sprinklers Form No. F_033314 Rev 15.1 Page 4 of 6 MICROFAST® QUICK I:II[ui7M RESPONSE PENDENT SPRINKLER VK302 (K5.6) _N11KJi 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com - -TIe Viking Microfast" Quick Respon '1 11r0 KEY ,, Perident Sprinkler VK302 . ixe E lcin fppl J )i' Base - Spnnkier Thread Size Nominal Overall Listings and Approvals' Part SIN K-Factor Length (Refer also to Design Criteria.) Number' - Style NPT BSP U.S. metric2 inches mm cULus' VdS VK302 Pendent 1/2' 15mm 5.6 80.6 2-1/4 I LPCB =C IY -12979 58 A1Z, B1Y D2, C2X Al I A1Z, B1Y D3Z ___ 066626TVK302Pendant 112" 15mm 5.6 80.6 2-1/4 58 Pendent 1/2" 15mm AIZ, B1Y, D2, C2X 18021 5.6 80.6 2-1/4 58 AiX, BIY Al AiX, B1Y DIX, dY8 I DIX, dY' -- Approved Temperature Ratings Approved Finishes Approved Escutcheons A - 135 'F (57 'C), 155 'F (68 'C), 175 'F 1 - Brass, Chrome, White X - Standard surface-mounted escutcheon or the (79 °C), 200 'F (93 'C), 286°F (141 'C) Polyesters', Black Polyes- Viking Micromatic0 Model E-1 Recessed Escutcheon B - 135 'F (57 'C), 155 'F (68 'C), 175 'F ter56 Y - Standard surface-mounted escutcheon or the (79 'C), and 200 'F (93 'C) 2- ENT5 Viking Microfast'2 Model F-I Adjustable Escutcheon, or recessed with the Viking Micro- C - 155 'F (68 'C), 175 'F (79 'C), and 3-Chrome . matic" Model E-1 • E-2, or E-3 Recessed Escutcheon 200 'F (93 'C) Z - Standard surface-mounted escutcheon or the b - 155 'F (68 'C), 175 'F (79 'C), 200 'F Viking Microfaste Model F-i Adjustable Escutcheon (93 'C), 286 'F (141 'C) Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 'cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. - 'CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001. CE Certified, Standard EN 12259-1, EC-certificates of conformity 0832-CPD-2001 and 0832-CPD-2003. MED Certified, Standard EN 12259-1, EC-certificates of conformity 0832-MED-1 003 and 0832-MED-1 008. cULus Listing Requirements: The Viking Microfast5 Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 Rev 15.1 Page 5 of 6 MICROFAST® QUICK sJII(JI1G ZMM LSPRINKLERVK302(K5.6) ESPONSE PENDENT The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com ..-. r :..era " 49 . The Viking Microfast Quick RbpOnSc 4, - ri' PenddtSrinkleVK3U2 . -•. . . Mxu,iiun175PSE(12_Bar;.WWP . .. A!t' Base Part Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals3 Number' SIN Style (Refer also to Design Criteria.) NPT BSP U.S. metric- Inches mm 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 1 58 A1Z, B1Y, D2X, C2 'rayT _ - 06662B VK302 Pendent 1/2" 15mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 18021 VK302 Pendent 1/2" 15 mm 5.6 1 80.6 2-1/4 1 58 AIZ, B1Y Approved Escutcheons Approved Temperature Ratings X - Standard surface-mounted escutcheon or the 'A - 135°F (57 °C), 155°F (68 °C). 175°F (79 °C), 200°F Viking Micromatic5 Model E-1 Recessed (93 °C), 286 °F (141 "C) Approved Finishes Escutcheon B - 135 °F (57 °C), 155 °F (68 °C), 175 "F (79 °C), and 1 -Brass, Chrome, White Polyester°, Y - Standard surface-mounted escutcheon or the 200 °F (93 °C) and Black Polyester4 Viking Microfast Model F-I Adjustable Escutcheon. C - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 "C), 286 2 - ENT5 or recessed with the Viking Micromatic5 Model E-1 °F (141 °C) or E-2 Recessed Escutcheon D - 155°F (68 °C), 175 "F (79 °C), 200 °F (93 °C) Z - Standard surface-mounted escutcheon or the I Viking Microfast Model F-I Adjustable Escutcheon Footnotes 'Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing. Other approvals may be in process. Other colors are available on request with the same Approvals as the standard colors. FM approved as corrosion resistant. FM Aparoval Requirements: The Viking Microfasr Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage upright and pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page 011I-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 Rev 15.1 Page 6 of 6 MICROFAST® QUICK RESPONSE PENDENT N41KJ:NG SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Ceiling Opening Size: 2-5/16" (518.7 mm) minimum 1/2" (IS mm) • 14" 2-1/2" (63.S mm) maximum I riru Fe24I8"I fl/4" (54 mm) 4 F fl IfT 1-3/4" 2" i 1(38 mm) (57 mm) II (51 mm) L#' I Mm. I . (44.5• mm) Max. Installed with a standard Installed with a Microfast Note: At maximum, adapter is 1/8" surface-mounted Model F-I Adjustable exposed 112" (12.7 mm) from escutcheon Escutcheon face of ceiling Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon Ceiling Opening Size: 25'iurn I- 2-1/8" ......2-1/8".. 154 mm) r:3 '_'.' t.54mmi 'Ii (4 j(286 mm) (51mm) (28.6 mm) Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-I and E-2 Recessed Escutcheons Form No. F_033314 Rev 15.1 (Added CCCF Approval)