Loading...
HomeMy WebLinkAbout2730 BRESSI RANCH WAY; ; FA090006; PermitCity of Carlsbad Fire Alarm Permit / Permit No: FA090006 2730 BRESSI Job Address: Status: ISSUED RANCH WY Permit Type: FALARM Applied 1/28/2009 Parcel No: 2131910700 Approved: 1/28/2009 Lot #: 0 Reference No.: Issued: 1/28/2009 PC #: . inspector: Project Title: BOYS & GIRLS CLUB TWO FIRE ALARM INSPECTIONS @ $65/00 EA I Applicant: Owner: JJJ ENTERPRISES 533 S VINEWOOD ST ESCONDIDOCA 760-747-3050 Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 * FAo1oO livomplorlp FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS BOYS & GIRLS CLUBS OF CARLSBAD 2730 BRESSI RANCH WAY CARLSBAD, CALIFORNIA 92008 FIRE ALARM SYSTEM fAo°L 000(o BOYS & GIRLS CLUBS OF CARLSBAD 2730 BRESSI RANCH WAY CARLSBAD, CALIFORNIA 92008 BILL OF MATERIALS NOTIFIER NFW2-100 FIRE ALARM CONTROL PANEL CSFM# 7165-0028:235 NOTIFIER FDU-80 REMOTE ANNUNCIATOR CSFM# 7120-0028:209 NOTIFIER FCPS-24S6 REMOTE POWER SUPPLY CSFM# 7315-0028:225 NOTIFIER NP-100 ADDRESSABLE PHOTOELECTRIC SMOKE DETECTOR CSFM# 7272-0028:231 NOTIFIER NOT-BG12LX ADDRESSABLE MANUAL PULL STATION CSFM# 7150-0028:199 NOTIFIER NMM-100P ADDRESSABLE MONITOR MODULE CSFM# 7300-0028:230 NOTIFIER NC-100R RELAY MODULE CSFM# 7300-0028:230 NOTIFIER ND-100 DUCT SMOKE DETECTOR CSFM# 3240-0028:236 SYSTEM SENSOR RTS-451 REMOTE TEST STATION CSFM# 7300-1653:110 WHEELOCK ZNS HORN/STROBE SERIES CSFM# 7125-0785:142 WHEELOCK ZRS STROBE SERIES CSFM# 7125-0785:141 WHEELOCK ASWP-2475W WEATHERPROOF HORN/STROBE SERIES CSFM# 7125-0785:131 dn-60417:B1 FireWarden-100-2(E) Rev 2 NOTI Fl E R& Intelligent Addressable FACP (a with Built-In Communciator by Honeywell .. . General The Notifier FireWarden-100-2 Rev 2 (NFW2-100 Rev 2) with Version 4.0 firmware is a combination FACP (Fire Alarm Control Panel) and DACT (Digital Alarm Communicator/Trans- mitter) all on one circuit board. This compact intelligent addressable control panel has an extensive list of powerful features. The SLC (Signaling Line Circuit) of the FireWarden-100-2 Rev 2 operates using a Rapid Group Polling communication proto- col technology that polls multiple devices simultaneously for a quicker device response time.This patented technology allows a fully-loaded panel with up to 198 devices to report an inci- dent and activate the notification circuits in under 10 seconds. With this improved polling, devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet. (Consult the wire table on page 5 for specific installation instructions.) The FireWarden-100-2 Rev 2's quick-remove chassis protects the electronics during construction. The backbox can be installed allowing field wiring to be pulled. When construction is completed, the electronics can be quickly installed with just two bolts. Available accessories include ANN-BUS devices as well as ACS LED, graphic and LCD annunciators, and reverse polar- ity/city box transmitter. The integral DACT transmits system status (alarms, superviso- ries, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. It also allows remote and local programming of the control panel using the PS-Tools Upload/ Download utility. In addition, the control panel may be pro- grammed or interrogated off-site via the public switched tele- phone network. Any personal computer with Windows® XP or greater, a compatible modem, and PS-Tools, the Upload/ Download software kit, may serve as a Service Terminal. This allows download of the entire program or upload of the entire program, history file, walktest data, current status and system voltages. The panel can also be programmed through the FACP's keypad or via a standard PS-2 computer keyboard, which can be plugged directly into the printed circuit board. This permits easy typing of address labels and other program- ming information. Version 4.0 firmware supports the following: ANN-bus devices, USB port, NAC circuit diagnostics, a new report has been added to the walk-test that lists untested devices, new device types added: audio telephone type code for NFV-25/50ZST (release pending), Photo Supervisory and auto-resettable Drill (non-latching). The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet saving the monthly cost of two dedicated business telephone lines. Although not required, the secondary tele- phone line may be retained providing backup communication over the public switched telephone line. NOTE: Unless otherwise specified, the term "Fire Warden-lOO-2" is used in this document to refer to both the Fire Warden-100-2 and the Fire Warden- 100-2E FACPs (Fire Alarm Control Panels). Like- wise, "NFW2400" refers to NFW2- WOE as well. Features Listed to UL standard 864, 9th edition. On-board DACT. Remote site or local USB port upload/download, using PS- Tools. Four Style V (Class B) or two Class A (Style Z) NAC cir- cuits. (Up to 6.0 amps total NAC power when using optional XRM-24B.) Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices. Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules or FDU-80, N-ANN-80 or ACS Annunciators. ANN-BUS for connection to following optional modules (cannot be used if ACS annunciators are used): - N-ANN-80(-W) Remote LCD Annunciator - N-ANN-I/O LED Driver - N-ANN-S/PG Printer Module - N-ANN-RLV Relay Module - N-ANN-LED Annunciator Module - N-ANN-RLED Annunciator Module alarms only ACS & Terminal-mode Annunciators: - ACS Annunciators: Up to 32 ACM Series annunciators (ACM-16AT or ACM-32 series). Cannot be used if ANN- BUS devices are used. - Terminal-mode Annunciators: Up to 32 FDU-80 annuncia- tors. ElA-232 printer/PC interface (variable baud rate) on main circuit board, for use with optional UL-listed printer PRN-6. Integral 80-character LCD display with backlighting. dn-60417:131 • 11/11/08—Page lot 6 Real-time clock/calendar with automatic daylight savings control. Detector sensitivity test capability (NFPA 72 compliant). History file with 1,000-event capacity. Maintenance alert warns when smoke detector dust accu- mulation is excessive. Automatic device type-code verification. One person audible or silent walk test with walk-test log and printout. Point trouble identification. Waterf low (nonsilenceable) selection per monitor point. System alarm verification selection per detector point. PAS (Positive Alarm Sequence) and presignal delay per point (NFPA 72 compliant). NOTE: Only detectors may participate in PAS. SLC LOOP: SLC can be configured for NFPA Style 4, 6, or 7 operation. SLC supports up to 198 addressable devices per loop (99 detectors and 99 monitor, control, or relay modules). SLC loop maximum length 10,000 ft. (3,000 rn). See wire table on page 5. NOTIFICATION APPLIANCE CIRCUITS (NACS): Four onboard NACs with additional NAC capability using output control modules (NC-lao). The four Class B NACs can be converted to two Class A NACs with NACKEY (included). Silence Inhibit and Auto Silence timer options. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAC. 2.5 amps maximum per each NAC circuit. NOTE: Maximum 24V0C system power output is shared among all NAG circuits and 24VDC special-application auxiliary power outputs. Total available output is 3.0 amps. Using the optional XRM-24B transformer increases 24VDC output to 6.0 amps. PROGRAMMING AND SOFTWARE: Autoprogram (learn mode) reduces installation time. Custom English labels (per point) may be manually entered or selected from an internal library file. Three Form-C relay outputs (two programmable). 99 software zones. Continuous fire protection during online programming at the front panel. Program Check automatically catches common errors not linked to any zone or input point. OFFLINE PROGRAMMING: Create the entire program in your office using a Windows®-based software package (NFW2-100 requires PS-Tools Programming software, available on VFWARDEN-CD and www.magni-fire.com). Upload/download system programming locally to the Fire- Warden-100-2(E) Rev 2 in less than one minute. USB programming with standard Mate-A to Male-B cable. User interface LED INDICATORS AC Power (green) Fire Alarm (red) Supervisory (yellow) Alarm Silenced (yellow) System Trouble (yellow) Maintenance/Presignal (yellow) Disabled (yellow) Battery Fault (yellow) Ground Fault (yellow) KEYPAD CONTROLS Acknowledge/Step Alarm Silence Drill System Reset (lamp test) 16-key alpha-numeric pad (similar to telephone keypad) 4 cursor keys Enter Product Line Information NFW2-100: FireWarden-100-2 Rev 2 198-point addressable Fire Alarm Control Panel, one SLC loop. Includes 80-character LCD display, single printed circuit board mounted on chassis, and cabinet. 120 VAC operation. NFW2-100R: Same as FireWarden-100 Rev 2, except in a red backbox. NFW2-100E: Same as NFW2-100 Rev 2, except with 240 VAC operation. 4XTM Reverse Polarity Transmitter Module: Provides supervised output for local energy municipal box transmitter, alarm, and trouble. VFWARDEN-CD: Contains PS-Tools Programming software for Windows®-based PC computer (cable not included). DP-9692B: Optional dress panel for FireWarden-100-2 Rev 2. TA-CE-B: Trim Ring for semi-flush mounting. BB-26:. Battery backbox, holds up to two 26 AH batteries and CHG-75. NFS-LBB: Battery box, houses two 55 AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120: Remote battery charging system for lead-acid bat- teries with a rating of 55 to 120 AH. Requires additional NFS- LBB for mounting. NOTE: CHG-120 or CHG-75 required for batteries larger than I8AH. BAT Series: Batteries, see data sheet DN-6933. XRM-24B(E): Optional transformer. Increases system power output to 6.0 amps. Use XRM-24BE with FireWarden-100-2E Rev 2. PRT/PK-CABLE: Cable printer/personal computer interface cable; required for printer or for local upload/download pro- gramming. PRN-6: UL listed compatible event printer. Uses tractor-fed paper. IPDACT-2/2UD, IPDACT Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT tele- phone output ports for internet communications over customer provided ethernet internet connection. Requires compatible Teldat VIsorALARM Central Station Receiver. Can use DHCP or static IP. (See data sheet dn-60408 for more information.) lPBRKT: Mounting kit for IPDACT-2/2UD in common enclo- sure. lPSPLT: V-adaptor option allows connection of both panel dialer outputs to one IPDACT-2/2UD cable input. COMPATIBLE ANNUNCIATORS N-ANN-80(-W): LCD Annunciator is a remote LCD annuncia- tor that mimics the information displayed on the FACP LCD display. Recommended wire type is un-shielded. (Basic model is black; order -W version for white; see DN-71 14.) Page 2 of 6— dn-60417:BI • 11/11/08 N-ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble and Supervisory. Ships with red or black enclosure (see DN-60242). N-ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DN-60242). N-ANN-RLY: Relay Module, which can be mounted inside the cabinet, provides 10 programmable Form-C relays. (See ON- 7107.) N-ANN-S/PG: Serial/Parallel Printer Gateway module pro- vides a connection for a serial or parallel printer. (See ON- 7103.) N-ANN-I/O: LED Driver Module provides connections to a user supplied graphic annunciator. (See DN-7105.) ACM-8R: Relay module provides 8 Form-C 5.0 amp relays. ACM Annunciator Series: LED-type fire annunciators capa- ble of providing up to 99 software zones of annunciation. Avail- able in increments of 16 or 32 points to meet a variety of applications. LDM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. FDU-80 (Liquid Crystal Display) point annunciator: 80-character, backlit LCD-type fire annunciators capable of displaying English-language text. NOTE: For more information on Compatible Annunciators for use with the Fire Warden-100-2 Rev 2, see the following data sheets (document numbers) ACM-817 (DN-3558), ACS/ACM Series (DN- 0524), LDM Series (DN-0551), FDU-80 (DN-6820). COMPATIBLE ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. NI-100: Addressable low-profile ionization smoke detector. NP-i 00: Addressable low-profile photoelectric smoke detector. NP-i OOT: Addressable low-profile photoelectric smoke detector with thermal sensor. NH-100: Fast-response, low-profile heat detector. NH-100R: Fast-response, low-profile heat detector with rate- of-rise option. NH-100H: Fixed high-temperature detector that activates at 190F/88C. ND-100: Photoelectric low-flow duct smoke detector. ND-100R:. Photoelectric low-flow duct smoke detector with relay option. NMM-100: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of- line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. NDM-100: Dual Monitor Module. Same as NMM-100 except it provides two Style B (Class B) only lDCs. NMM-100P: Miniature version of NMM-100. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. NZM-100: Similar to NMM-100, but may monitor up to 20 con- ventional two-wire detectors. Requires resettable 24 VDC power. Consult factory for compatible smoke detectors. NC-100: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. NC-100R: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. NOT-BG12LX: Addressable manual pull station with interface module mounted inside. N100-ISO: Fault Isolator Module. This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 operation). SMB500: Used to mount all modules except the NMM-100P. NZM-100-6: Six-zone interface module. Mount one or two modules in a BB-XP cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-25. NOTE: For more information on Compatible Addressable Devices for use with the Fire Warden-100-2 Rev 2, see the following data sheets (document numbers): N100-ISO (DN-6994), NP-100 series (DN-6995). NI-100 (DN-6996), NH-100 series (DN-6997), ND-100 series (DN-7006), NMM- 100/NMM-100P/NDM- 100/NZM- 100 (DN- 6999), NC- 100/NC-bOA (DN-7000), NOT-BG I2LX (DN-7001), and NZM- 100-6 (DN-60150). dn-60417:81 .11/11/08—Page 3o1 6 ............................ _ I ANN-BUS or ANN-BUS DEVICES EIA -485 in ACS mode N-AN N-80, N-ANN-LED (two wires) N-ANN-S/PG. N-ANN-I/O Fire Warden-100-2 Rev 2 Fire Alarm Control! Communicator -0. SMOKE DETECTORS NP-100, NP-100T, Nl-100 24V0C 4........ ANNUNCIATORS ACS/ACM, LDM NOTE: System can use either ANN-BUS devices OR A CS-mode annunciators. They cannot be used simultaneously. EIA -485 INTERFACE (four wires) Optional REVERSE POLARITY! CITY BOX OUTPUT 11141111 8 FORM-C, 5-AMP RELAYS (optional, order ACM-8R) NACs (Notification Appliance Circuits) BELLS, SIGNALS, STROBES EIA -232 INTERFACE (PIM-24) built into the motherboard P, I Rgwe PRI NTER NOTE: System can use either the printer OR the FDU-80. They cannot be used simultaneously. 24 VDC ccIJ FDU-80 Up to 6,000 ft. (1825.8 m) between each FDU-80 in the ElA-485 loop, and between each FDU-80 and the FACP —+ L HEAT DETECTORS NH-100, NH-100R, NH-100H DUCT DETECTOR ND-100, ND-100R —* MONITOR! CONTROL NMM-100, NZM-100, NDM-100. N100-ISO, NC-100. NC-100R ''III ADDRESSABLE MULTI-MODULE NZM-1 00-6 MINI MONITOR N MM-i OOP PULL STATION NOT-BG1 2LX Page 4 of 6 — dn-60417:B 1 • 11/11/08 Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interference. Wire size should be no smaller than 18 AWG (0.78 mm2) and no larger than 12 AWG (3.1 mm2). The wire size depends on the length of the SLC circuit. Use the follow- ing table to determine the specific wiring requirements for the SLC. SLC Wire Distance in Feet Wire Size Wire Type Requirements (m) Non-Plenum (FPLR): Twisted-pair, unshielded 10,000feet (3.048 m) 12 AWG (3.31 mm2) Genesis 4315, Belden 5020UL Plenum (FPLP): Genesis 4515, Belden 6020UL Non-Plenum (FPLR): Twisted-pair, unshielded 8,000 feet (2,438 m) 14 AWG (2.08 mm2) Genesis 4313, Belden 5120UL Plenum (FPLP): Genesis 4513, Belden 6120UL Non-Plenum (FPLR): Twisted-pair, unshielded 4,875 feet (1,486 m) 16 AWG (1.31 mm2) Genesis 4311. Belden 5220UL Plenum (FPLP): Genesis 4511, Belden 6220UL Non-Plenum (FPLR): Twisted-pair, unshielded 3,225 feet (983 m) 18 AWG (0.821 mm2) Genesis 4306, Belden 5320UL Plenum (FPLP): Genesis 4506, Belden 6320UL FireWarden-100-2 Wire Requirements dn-60417:B1.11/11/08— Page 5of6 SYSTEM SPECIFICATIONS System Capacity Intelligent Signalling Line Circuits . 1 Addressable device capacity..........................................198 Programmable software zones.........................................99 ACS Annunciators ............................................................32 ANN-bus devices................................................................8 Electrical Specifications AC Power: FireWarden-100-2 Rev 2:120 VAC, 60 Hz. 3.0 amps. FireWarden-100-2 Rev 2(E): 240 VAC, 50 Hz, 1.5 amps. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Battery: Two 12 V 18AH lead-acid batteries. Battery charger capacity: 7-18 AH. FireWarden-100-2 Rev 2 cabinet holds maximum of two 18 AH batteries. Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Each terminal block pro- vides connections for two Style V (Class B) or one Style Z (Class A) for a total of four Style V (Class B) or two Style Z (Class A) NACs. Maximum signaling current per circuit: 2.5 amps. End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL listed) for Style V (Class B) NAC. Refer to panel documen- tation and Notifier Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0 amps © 30 VDC (resistive), 0.5 amps © 30 VAC (resistive). Form-C relays. Special Application Power (24 VDC Nominal): Jumper selectable (JP4) for conversion to resettable power output. Up to 0.3 amps total DC current available from each output. Power-limited. Four-Wire Resettable Special Application Smoke Detector Power (24 VDC nominal): Up to 0.3 amps for powering four- wire smoke detectors. Power-limited. Refer to the Notifier Device Compatibility Document for listed compatible devices. Remote Sync Output: Remote power supply synchronization output. Nominal special application power: 24 VDC. Maximum current: 40 mA. End-of-Line Resistor: 4.7K ohm. Output linked to NAC 1 control. Supervised and power-limited. Telephone Interface: Unless used with Teldat VISORALARM, requires dedicated business telephone number with a mini- mum of 5 volts DC (off-hook voltage). Obtain dedicated phone line directly from your local phone company. Do not use shared phone lines or PBX (digital) type phone line extensions. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.12" (.30 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.20 (13.34 cm.) deep. Trim Ring (TR-CE-B): 22.00 (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 490C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 30F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15- 27°C/60 - 80°F NFPA Standards The FireWarden-100-2 Rev 2 complies with the following NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTM). - REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be con- nected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTM is required.) - PROPRIETARY (Automatic, Manual, Waterflow and Sprinkler Supervisory). - CENTRAL STATION (Autoinatic, Manual, Waterflow and Sprinkler Supervisory). - OT, PSDN (Other Technologies, Packet-switched Data Network) Agency Listings and Approvals The listings and approvals below apply to the basic FireWar- den-100-2 Rev 2 control panel. In some cases, certain mod- ules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S635 FM approved CSFM: 7165-0028:235 MEA: 120-06-E, Volume 2 FireWarden® and Notifier® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. 02008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended lobe used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. E1111INEEKINS &MANUMC1IRINf All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 6ot6—dn-60417:B1 • 11/11/08 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL. FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0028:235 Page 1 of 1 CATEGORY: Control Unit (Non High-Rise) LISTEE: Notifier, One Fire-Lite Place, Northford, CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Models Fire Warden 100 and *Fire Warden 100-2 addressable control units. Local, auxiliary, remote station, central station and proprietary (protected premise). Refer to listee's data sheet for detailed product description, operational considerations and required/optional accessories. When required, accessories shall be CSFM listed. RATING: . 120 VAC, 60 Hz, 2.06 A Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes andordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as an addressable fire alarm control panel for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, gth Edition Standard. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. XLF: 7165-0075:208 Rev/Recert 06-27-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 12, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division DN-6820:A • D-123 0 NOTIFIER® -- - - - by Honeywell Annunclatom GENERAL FDU.80 80 Character Liquid Crystal Display The FDU-80 is a compact, cost-effective, 80 character, backlit LCD Fire Annunciator for use with the NOTIFIER FireWarden- 100-2, NFS-640, NFS2-640, and NFS-320 Fire Alarm Control Panels (FACPs). The FDU-80 mimics the display of the control panel and displays complete system point status information. Up to 32 FDU-80s may be connected onto the EIA-485 Terminal Mode port of each control panel. The FDU-80 requires no programming, which saves time during system commissioning. NOTES: The FDU-80 is compatible with the NOTIFIER NFS-640 Rev. 2.01 or higher. The FDU-80 can be used on the same data loop as the LCD-80/LCD-80TM annunciators revision 1.6 software or higher. FEATURES 80-character Liquid Crystal Display. Mimics all display information from the host panel. Control switches for System Acknowledge, Signal Silence, Drill and Reset with enable key. System status LEDs for Power, Alarm, Trouble, Supervi- sory, and Alarm Silenced. No programming necessary FDU-80 connects to the ter- minal mode port. Displays device type identifiers, individual point alarm, trou- ble or supervisory, zone and custom alpha labels. Time and date display field. Aesthetically pleasing design. May be powered by 24 VDC from the host FACP or by remote power supplies (requires 24 VDC). Up to 32 FDU-80 annunciators per FACP. Plug-in terminal blocks for ease of installation and service. Can be remotely located up to 6,000 feet (1828.8 m) from host control panel. Local piezo sounder with alarm and trouble resound. Semi-flush-mounts to 2.188I5.556 cm (minimum) deep, three-gang electrical box (NOTIFIER P/N 10103) or three- gangable electrical switchbox. Surface-mounts to NOTIFIER S1313-3 surface backbox. OPERATION The FDU-80 annunciator provides the FACP with point annun- ciation with full display text on an 80-character LCD display. The FDU-80 also provides an array of LEDs to indicate system status, and also includes control switches for remote control of critical system functions. The FDU-80 provides the FACP with up to 32 remote serially connected annunciators. All field-wiring terminations on the FDU-80 use removable, compression-type terminal blocks for ease of wiring and circuit testing. Communication between the FACP and the annunciators is accomplished over an ElA-485 serial interface, which greatly reduces wire and installation cost over traditional systems. Six wires total are required: four for the EIA-485 communications (two in and two return): and two for the 24 VDC regulated power. Dip switches control local functions such as: piezodis- able, control switches/key switch disable, transmit/receive mode. INSTALLATION The FDU-80 can be semi-flush mounted to a 2.188"/5.556 cm (minimum) deep, three-gang electrical box (NOTIFIER P/N 10103) or three-gangable electrical switchboxes. Alternately, an SBB-3 surface backbox is available for surface-mount appli- cations. AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL-Listed: 5635 ULC Listed: CS100 ' MEA Listed: 245-00-E CSFM: 7120-0028:209 FM Approved ORDERING INFORMATION FDU-80 80 character, backlit, LCD Fire Annunciator with control switches for remote control of system functions, and key-switch lock. 10103 Three-gang electrical box, minimum 2.188" (5.556 cm) deep, for semi-flush-mount applications. SBB-3 Three-gang surface backbox for surface-mount applications. ON-6820:A • 4/19107 - Page 1 of 2 FDU-80 TERMINAL MODE WIRING EXAMPLE Up to 6,000 ft. (1828.8 m) between EACH DEVICE in the EIA-485 loop-',.. Terminal Mode \ ---.- Ir FDU-80 FDU-8 EIA-485 (2-wires) g-", 24 VI it; 'I Up to 6,000 ft. (1828.8 m) Terminal Mode / back from last device ..!Pi!!Q.. to end of EIA-485 loop ElA-485 return ______ 4 NFS-320 NOTES: EIA-485: Maximum of 6,000 feet (1828.8 m) cable length from FACP to FDU-80 annunciators and back to,FACP (6,000 feet (1828.8 ml total). Circuit is power-limited. Up to 32 FDU-80 annunciators may be used on the EIA -4 85 circuit. When multiple FDU-80s are used, certain panels will require additional power supplies (refer to panel documentation). Between each FDU-80 annunciator are four wires: a twisted-shielded pair for data communications and a pair for 24 VDC power. The return circuit only requires two wires for data communication supervision, wired from the last FDU-80 annunciator on the loop. On the AFP-300/400, software revision 3.62 or higher is required. MOUNTING TO BACKBOX(ES) The FDU-80 annunciators can be semi-flush-mounted in a three-gang electrical box with a minimum depth of 2.188 (5.556 cm) (NOTIFIER P/N 10103). The FDU-80 annunciators can be mounted in three gangable electrical switch boxes connected together. NOTE: Alternately, FDU-80 annunciators can be mounted to the SBB-3 surface backbox for surface-mount applications. Mounting FDU-80 Flange Holes (4) 0 0 5.813" (14.764 cm) wide x 4" (10.16 cm) high x minimum 2.188" (5.556 cm) deep, three-gang electrical box (NOTIFIER PIN 10103, shown at right). ©2008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I so oo 1 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. INtINIERINC & MRNUJR1UNC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. www.nOtifier.com Page 2 of 2— DN-6820:A • 4/19/07 FIRE ALARM ANNUNCIATOR OEM F--- r-~ C:Ez •0 i•iias ii II' oo a ROIl 3120.00 rl CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-0028:209 Page 1 of 1 CATEGORY Annunciators LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 FAX (203) 484-7309 Models FDU-80 and *FDu..80G remote fire annunciators. Units are compact 80-character, backlit LCD fire annunciators. Refer to listee's data sheet for additional detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Listee's name, product number, electrical rating and UL label. Listed as annunciators for use separately listed compatible fire alarm control units. Refer to manufacturer's installation manual for details. Rev. 10-03-06 jw ' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 12, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division July 20, 2004 DN-6927 • E-30 (0 NOTIFIER® GENERAL The FCPS-24S6 (6-amp) and FCPS-24S8 (8-amp) are com- pact, cost-effective remote power supplies with battery charger. The FCPS-24S6/-2458 may be connected to any 12- or 24- volt Fire Alarm Control Panel (FACP) or may be used as a stand-alone supply. Primary applications include Notification Appliance (bell) Circuit (NAC) expansion (to support ADA re- quirements and NAC synchronization) or auxiliary power to support 24-volt system accessories. The FCPS-24S6/-24S8 provides regulated and filtered 24 VDC power to tour notifi- cation appliance circuits configured as either tour Class B (Style Y) or Class A (Style Z, with ZNAC-4 option module). Alter- nately, the Four outputs may be configured as all non-resettable, all resettable, or two non-resettable and two resettable. The FCPS-24S6/-2458 also contains a battery charger capable of charging up to 18 AH batteries. FEATURES UL-Listed NAC synchronization using System Sensor, Wheelock, or Gentex "Commander 2" appliances. Cascadable for up to ten power supplies (four forGentex) with strobe timing maintained. Operates as a "sync follower" or as a "sync generator" (de- fault). See note on page 2. Contains two fully-isolated input/control circuits - triggered from FACP NAC (NAC expander mode) or jumpered per- manently "ON" (stand-alone mode). Four Class B (Style Y) or tour Class A (Style Z, with ZNAC-4 module) NACs. 6-amp(FCPS-24S6) or 8-amp (FCPS-24S8) full load output, with 3 amps maximum/circuit, in NAC expander mode (UL 864). 4-amp (FCPS-24S6) or 6-amp (FCPS-2458) continuous out- put in stand-alone mode (UL 1481). Compatible with coded inputs; signals passed through. Optional power-supervision relay (A77-716B). In stand-alone mode, output power circuits may be config- ured as: resettable (reset line from FACP required), non- resettable, or a mix of two and two. Fully regulated and filtered power output - optimal for pow- ering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated/filtered power. Power-limiting technology meets UL power-limiting require- ments. Form-C normally-closed trouble relay. Fully supervised power supply, battery, and NACs. Selectable earth fault detection. AC trouble report selectable for immediate or 8-hour delay. Works with virtually any UL 864 fire alarm control which uti- lizes an industry-standard reverse-polarity notification cir- cuit (including unfiltered and unregulated bell power). Requires input trigger voltage of 9.0 - 32 VDC. Self-contained in compact, locking cabinet— 15" (38.1 cm) high x 14.5" (36.83 cm) wide x 2.75" (6.985 cm) deep. Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batteries. FCPS-2456 and FCPS-24S8 6-Amp and 8-Amp 24-Volt Remote Power Supplies Section: Power Supplies J California 7315-0028:225 LISTED APPROVED rj1 S635 MEA 299-02-E -. . . t.t' '. '..................- • ,.. Cl.',. • • • r'•"• ° Battery charger may be disabled via DIP switch for applica- tions requiring larger batteries. Fixed, clamp-type terminal, blocks accommodate up to 12 AWG (3.1 mm') wire. STANDARDS and CODES The FCPS-2456/-24S8 complies with the following standards: NFPA 72 National Fire Alarm Code. UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode). UL 1481 Power Supplies for Fire Alarm Systems (stand- alone mode). SPECIFICATIONS Primary (AC) power: FCPS-2456/-2458: 120 VAC, 60 Hz, 3.2 A maximum. Wire size: minimum #14 AWG (2.0 mm2) with 600 V insulation. Control input circuit: Trigger input voltage: 9 to 32 VDC. Trigger current: 2.0 mA (16-32 V). Per input: 1.0 mA (9- 16 V). Trouble contact rating: 5 amps at 24 VDC. NOTIFIER® is a Honeywell company. This document is not intended 10 be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications IS09001 or anticipate all requirements. All specifications are subject to change without notice. W-1:112131113M For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 ENGINEERING & MANUFACTURING NOTI Fl E R 12 Clintonville Road, Northford. Connecticut 06472 QUALITY SYSTEMS Auxiliary power output: specific application power 500 mA maximum. Output circuits: +24 VDC filtered, regulated. 3.0 amps maximum for any one circuit. Total continuous current for all outputs (stand-alone mode): for FCPS-24S6: 4.0 amps maximum; for FCPS-24S8: 6.0 amps maximum. Total short-term current for all outputs (NAC expander mode): for FCPS-24S6: 6.0 amps maximum; for FCPS-24S8: 8.0 amps maximum. Secondary power (battery) charging circuit: Supports lead-acid batteries only. Float-charge voltage: 27.6 VDC. Maximum-charge current: 1.5 amps Maximum battery capacity: 18 AH. APPLICATIONS Example 1: Expand notification appliance power an addi- tional 6.0 amps (FCPS-2456) or 8.0 amps (FCPS-24S8). Use up to four Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZNAC-4). For example, the FACP notification appliance circuits will activate the FCPS when reverse-polar- ity activation occurs. Trouble conditions on the FCPS are sensed by the FACP through the notification appliance circuit. Example 2: Use the FCPS to expand auxiliary regulated 24-volt system power up to 4.0 amps (FCPS-2456) or up to 6.0 amps (FCPS-2458). Both resettable and non-resettable power options are available. Resettable outputs are created by connecting the resettable output from the FACP to one or both of the FCPS inputs. Example 3: Use addressable control modules to activate the FCPS instead of activating it through the FACP notification appliance circuits. This typically allows for mounting the FCPS at greater distances* away from the FACP while expanding system architecture in various applications. For example, an addressable, control module is used to acti- vate the FCPS, and an addressable monitor module is used to sense FCPS trouble conditions. Local auxiliary power output from the FCPS provides power to the addressable control module. 'Addressable FACPs are capable of locating control and monitor Style Y NAG or modules at distances of up to Door Holder 10,000 feet (3048 meters). Power St AGENCY LISTINGS Output #4 Ou AND APPROVALS SYNC FOLLOWER/GENERATOR NOTE In some instaiiations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by the FACP. When installed at the end of a NAC wire run, the FCPS-2456/-24S8 can track (i.e., "follow") the strobe synchronization timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the additional strobes attached to the FCPS. When the FCPS-2456/-24S8 is configured (via DIP switch set- tings) as a "sync follower," the FCPS's NAC outputs track the strobe synchronization pulses present at the FCPS's sync in- put terminal. The pulses originate from an upstream FACP or other power supply. When the FCPS-24S6/-24S8 is configured (via DIP switch set- tings) as a "sync generator," the FCPS's sync input terminals are not used. Rather, the FCPS is the originator of the strobe synchronization pulses on the FCPS's NAC outputs. In 'sync generator" mode, the sync type (System Sensor, Wheelock, or Gentex) is selectable via DIP switch settings. PRODUCT LINE INFORMATION FCPS-24S6:6.0 amp, 120 VAC remote charger power sup- ply. Includes main printed circuit board, transformers, enclo- sure (15" [38.1 cm] high x 14.5" [36.83 cm] wide x 2.75" [6.985 cm] deep), and installation instructions. FCPS-24S8:8.0 amp, 120 VAC remote charger power sup- ply. Includes main printed circuit board, transformers, enclo- sure (15" [38.1 cm] high x 14.5" [36.83 cm] wide x 2.75" [6.985 cm] deep), and installation instructions. ZNAC-4: Class A (Style Z) NAC option module. A77-7168:12/24 VDC end-of-line relay for monitoring four- wire smoke detector power. BAT-1270: Battery, 12 volt, 7.0 AH (two required. see BAT Series data sheet DN-6933). PS-1270: Battery, 12 volt, 7.0 AH (two required, see PS Series data sheet DN-1 109). NOTE: All NAC outputs can be converted to Style Z with ZNAC-4 option module. FCPS Trouble le Y NAC Style V NAG Style V NAC Contact itput #3 Output #2 Output #1 Output See the first page of this data sheet for listing agencies and file numbers. These listings and ap- provals apply to the FCPS-24S6 and the FCPS-2458. In some cases, certain modules or appli- AC • cations may not be listed by cer- Power tam approval agencies, or listing may be in process. Consult fac- tory for latest listing status. INPUT/OUTPUT FUNCTIONS are programmable by SW1 DIP switch settings 24 VDC Specific Application Power NAC Control Input #2 (from FACP) NAC Control Input #1 (from FACP) FCPS Battery Charger Page 2 of 3 - DN-6927 . 07/20/04 Sync Input 8827blok.wn,I SIMPLIFIED BLOCK DIAGRAM 162: Power-Limited, NAC/Out 1 + Supervised in NAC Mode NAC/Out 1 - with Jumpers J5, JP6, NAC/Out 2 + TB1: Supervised JP7, & JPS in positions NAC/Out 2- - Earth shown below. NAC/Out 3 + I NAC/Out 3- - AC Neutral NAC/Out 4+ I I r— AC Hot NAC/Out 4-----, I I I 1J2 lot D I lol - L2J rii 0 0 Non-Power-Limited 101 J2:To Transformer #2 101 JI:lo Transformer #1 LJ 0 0 0 _ F1 0 Fl: 0 z Battery Fuse 15A. 30 V -4 _____ 0 -4 g jp4 liii 52 act) __ [_L - Battery LEDs (L to R): -D + Battery -AC Power (green) Ground Fault (yellow) m JP4: Supervised, - Battery Trouble (yellow) o Non-Power-Limited - NAC Trouble (yellow) 18 AH, 24 VDC - Charger Trouble/AC Loss (yellow) BOARD LAYOUT J P1 ""' hi tiraau.c, ' - J3: ZNAC-4 4-Tj Connector I Coded/Non-Coded JP2 & JP3: Input Selection 0 - - - Aux. Common - - + Aux. 24 VDC - - - Control Input 2 - - + Control Input 2 - - - Out Common - - I- Out/Trouble Contact - - - Control Input 1 - - i- Control Input 1 - - - Sync Input - - + Sync Input NOTE: Auxiliary Power - Output is power-limited but NOT supervised. Normally Open Normally Closed Common (shown energized) TB5: Trouble Relay 162 0 Form-C Fail-Safe mama 0 8 7 6 5 4 3 2 1 0 3 2 1 TB5 nn c JPI: Ground Fault fl U (JU Detection Auxiliary Output: 10 500 mA Specific- Application Power 06 2 Swi Ci - I&L[L4411 TB4 SW1: Programming DIP Switches CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE CAL FIRE LISTING No. 7315-0028:225 Page 1 of I CATEGORY: Power Units LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Models FCPS-24S6 and FCPS-24S8 are power limited power supply/battery chargers used for supervision and expanded power driving capability of up to four Notification Appliance Circuits (FACP Fire Circuits, Signaling Devices) or resettable/non resettable outputs. Model ZNAC-4 Class A converter. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: 120 VAC, 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction: MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a Power Supply/Battery Charger for use with separately listed compatible fire alarm control units. XLF: 7315-0075:206 1-24-2003KK This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 12, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division June 15, 2005 DN-6995 • A1-310 NOTUFflER by Honeywell GENERAL The NP-100 and NP-100T addressable, low-profile plug- in photoelectric detectors use a state-of-the-art photoelec- tric sensing chamber with communications to provide open area protection and.are used exclusively with NOTIFIER's FireWarden-100 Addressable Fire Alarm Con- trol Panel (FACP). The NP-100T adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C). Since these detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor, light to provide a local, visible sensor indication. Remote LED annunciator capability is available as an optional accessory (P/N RA400Z). FEATURES SL loop: Two-wire loop connection. Unit uses base for wiring. Addressing: Addressable by device. Direct Decade 01 - 99 (FireWarden-100) entry of ad- dress. V Architecture: Unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires. Sleek, low-profile design. Integral communications and built-in type identification. Built-in tamper-resistant feature. Removable cover and inect-resistant screen for simple field cleaning. Operation: Withstands air velocities up to 4,000 feet-per-minute (20 rn/sec.) without triggering a false alarm. Factory preset at 1.5% nominal sensitivity for panel alarm threshold level. Visible LED "blinks" when the unit is addressed (com- municating with the fire panel) and latches on in alarm. Mechanicals: Sealed against back pressure. Direct surface mounting or electrical box mounting. Mounts to: single-gang box, 3.5(8.89cm) or 4.0" (10.16 cm) octagonal box, or 4.0' (10.16 cm) square electrical box (using a plaster ring - included). V Other system features: Fully coated circuit boards and superior RF/transient NP-100 and NP-100T Addressable Photoelectric Detectors Section: Addressable 5iiJ Calif <9> ornia APPROVED LISTED = S1115 MARYLAND MEA State Fire Marshal 243-02-E Vol. II Permit # 2173 NP-100 with B71OLP base -••:. C NP-lOOT with B71OLP base 'Q 6935phol.1po protection. 94-VO plastic flammability rating. Low standby current. Options: Remote LED output connection (P/N RA400Z). SPECIFICATIONS Voltage range: 15 —32 VDC (peak). Standby current: 300 pA @ 24 VOC. V LED current: 6.5 mA © 24 VOC (latched "ON"). Air velocity: 4,000 ft./min. (20 rn/sec.) maximum. Diameter: 6.1' (15.5 cm) installed in B71OLP base. Height: 2.1" (5.33 cm) installed in B71OLP base. Weight: 3.6 oz. (102 g). Operating temperature range: for NP-100: 0°C to 49°C (32°F to 1200F); for NP-100T.- 0°C to 38°C (32°F to 100°F). Temperature: 0°C - 49°C (32°F - 1200F). Relative humidity: 10% - 93%, non-condensing. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. IS09001 For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 93303303= NOTI Fl E R INGINEEMNS & MANUFACTURING by Honeywell 12 Clintonville Road. Northlord, Connecticut 06472 QUALITY SYSTEMS APPLICATIONS Use photoelectric detectors in life-safety applications to provide a broad range of fire-sensing capability, espe- cially where smoldering fires are anticipated. Ionization detectors are often better than photoelectric detectors at sensing fast, flaming fires. CONSTRUCTION These detectors are constructed of off-white LEXAN®. NP-100(T) plug-in, low-profile smoke detectors are de- signed to commercial standards and offer an attractive appearance. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. INSTALLATION NP-100(T) plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base on box which is at least 1.5 inches (3.81 cm) deep. Suitable boxes include: 4.0 (10.16 cm) square box with plaster ring. 4.0 (10.16 cm) octagonal bx. 3.5" (8.89 cm) octagonal box. Single-gang box. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring '7- taps" or branches are permitted for Style 4 (Class B) wiring. OPERATION Each NP-100(T) uses one of 99 possible addresses on the FireWarden-100 Signaling Line Circuit (SLC). It re- sponds to regular polls from the system and reports its type and status. The NP-100(T) addressable photoelectric sensor's unique unipolar chamber responds quickly and uniformly to a broad range of smoke conditions and can withstand wind gusts up to 4,000 feet-per-minute (20 m/sec.) with- out sending an alarm level signal. Because of its unipo- lar chamber, the NP-100(1) is approximately two times more responsive than most photoelectric sensors. This makes it a more stable detector. DETECTOR SENSITIVITY TEST Each detector can have its sensitivity tested (required per NFPA 72, Chapter 7 on Inspection, Testing and Mainte- nance) when installed/connected to a FireWarden-100 addressable fire alarm control panel. The results of the sensitivity test can be printed off the FireWarden-100 for record keeping. PRODUCT LINE INFORMATION NP-11 00 Addressable photoelectric detector; B71OLP base included." NP-100T Same as NP-100 but with thermal element; B71OLP base included." RA400Z Remote LED. Mounts to a single-gang box. B71OLP Plug-in detector base. Dimensions: 6.1' (15.5 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, 3.5" (8.89 cm) octagonal box, or single-gang box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B224RB Plug-in System Sensor relay detector base. Diameter: 6.2' (15.75 cm). Mounting: 4.0" (10.16 cm) square box with or without plas- ter ring, 4.0" (10.16 cm) octagonal box, or 3.5" (8.89 am) octagonal box. All mounting boxes have a minimum depth of 1.5' (3.81 cm). B224B1 Plug-in System Sensor isolator detector base. Maximum 25 devices between isola- tor bases (see DN-6994). Diameter: 6.2" (15.75 cm). Mounting: 4.0' (10.16 cm) square box with or without plaster ring, 4.0' (10.16 cm) octagonal box, or 3.5" (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B501BH Plug-in System Sensor sounder detector base. Diameter: 6.0" (15.24 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring; Mounting box has a minimum depth of 1.5" (3.81 cm). "Prior to 03/28/05, the B71OLP base was sold separately. Page 2012 - DN-6995 • 06/15105 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0028:231. Page 1 of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: Notifier, One Fire-Lite Place, Northford, CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Models NP-100 and NP-100T photoelectric type smoke detectors. Model NP-100T has a 1350F supplement integral heat sensor which only assists in a fire situation. The purpose of this thermal circuitry is to increase the sensitivity of the detector. This thermal circuitry is NOT approved for use as a heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detector for use with separately listed compatible fire alarm control units. All units are suitable for installation inside air duct with a maximum air velocity of 4000 fpm. Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-0075:194 11-03-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 121 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division DN-7001 :A • Al -380 NOT.BGI 2LX Addressable Manual Pull Station by Honeywell ET ::::T;f'TT General The Notifier NOT-BG12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for FireWarden series intelligent control panels. Because the NOT-BG12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated.. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4" (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanicsms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable LEXAN® (or polycarbonate equivalent) with a textured finish. Specifications Normal operating voltage: 24 VOC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC loop current: pA. Ambient Temperature: 32°F to 120°F (0°C to 49°C) Relative Humidity: 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F) For use indoors in a dry location Installation The NOT-BG12LX will mount semi-flush into a single-gang, double-gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O sur- face backbox. If the NOT-BG12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). The NOT-BGI2LX Addressable Manual Pull Station Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle: clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. TwO rotary decimal switches allow address settings (1 —99 on FireWarden-100-2, 1 —50 for FireWarden-50). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored LEXAN (or polycarbonate equivalent) with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O: or semi-flush mounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. DN-7001:A • 02105/2008 - Page 1 of 2 Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information NOT-BG12LX: Dual-action addressable pull station. Includes key locking feature. SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. Back of station without door Terminal Connections: 1 SLC (-); 2 SLC (+) Cover open to show easy access to miniature monitor module, rotary switch, and UL label. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. BG12TR: Optional trim ring. 17021: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL Listed: S692 MEA: 67-02-E Vol. IV CSFM: 7150-0028:199 FM Approved 130)2 (2 2 3 ;;;:-'%3 '! 10 5 _L I ROTARY DECIMAL SWITCHES Do not remove tab. Detail ol BREAKAWAY TAB* a ,, ;._..•-.... 14I Notifier® is a registered trademark of Honeywell International Inc. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. 02008 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. isO 9001 U I We cannot cover all specific applications or anticipate all requirements. _d E111111901113 & MN011I1URING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the u.S.A. For more information, contact Notifier. Phone: (203) 484-7161. FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-7001 :A • 02105/2008 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE. FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0028:199 . Page 1 of 1 CATEGORY: Boxes/Pull Stations LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484*7161 FAX (203) 484-7309 DESIGN: Models NBG-12, NBG-12S, NBG-12LR, NBG-12LRA, NBG-12LAO, NBG-12LAOB, NBG- 12-LO, NBG-I2LOB, NBG-12W, NBG-12LW, NBG-12NC, NBG-12WP, NBG-12LWP, NBG- 12L, NBG-I2LX, NBG-I2LA, NBG-I2PS, NBG-I2LSP, NBG-12LPS, NBG-12LPSP, NBG- 12SP, NOT-BG12LX, and *NBG..12L)(sp fire alarm pull boxes. All units except Model NBG- 12S are dual action pull stations. Models NBG-12LR and NBG-12LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. - INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-I2WP, NBG-I2LW, NBG-12W, NBG-12LWP, NBG-12LAO, NBG-12L0, NBG- I2LAOB and NBG-I2LOB are intended for outdoor use when installed with Models WBB, SB- I/O, or WP-1 0 back box. Refer to listee's Installation Instruction Manual for details. Rev. 1-06-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 12, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division NMM-100 and NZM-100 dn-6999:a • Al -350 Monitor Modules NOTI Fl F. W NMM-1001 NMM-100P9 NZM-100, and NDM-100 for FireWarden Systems by Honeywell i General _____________ Four different monitor modules are available for Notifier's Fire- Warden-series intelligent control panels to suit a variety of applications. Monitor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detec- tors and pull stations, or monitor and power a circuit of two- wire smoke detectors (NZM-100). NMM-100 is a standard-sized module (typically mounts to a 4" (10.16 cm) square box) that supervises either a Class A (Style 0) or Class B (Style B) circuit of dry-contact input devices. NMM-100P is a miniature monitor module (a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D) used to supervise a Class B (Style B) circuit of dry-contact input devices. Its compact design allows the NMM-100P to often be mounted in a single-gang box behind the device it monitors. NZM-100 is a standard-sized module used to monitor, and supervise compatible two-wire, 24 volt, smoke detectors on a Class A (Style 0) or Class B (Style B) circuit. NDM-100 is a standard-sized dual monitor module used to monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. NMM-100 Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFl) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on NFW-100, 01 —99 on NFW-50. LED flashes during normal operation and latches on steady to indicate alarm. The NMM-100 Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (lDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. NMM-100 APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style 0 (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. r19 ° a detail of NDM-100 - note (8 1 "ones" addresses are 0, 2, ' 2 4,6,8only 3 4 oO9 NMM-100 OPERATION Each NMM-1 00 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). NMM-100 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum operating current: 375 .iA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49"C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5' (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. NMM-100P Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire FACP. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. dn-6999:a • 04/28/08 - Page 1 of 6 Direct-dial entry of address: 01 - 159 on NFW-100, 01 —99 on NFW-50. 1415 o 1 ADDRESS 0 12(3IT [ LOOP 98;6 9 8 76 TENS ONES - o lLU .1 Uj -..1 l7O ca The NMM-100P Mini Monitor Module can be installed in a sin- gle-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mount- ing. The NMM-100P is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiating device circuit for normally-open-contact fire alarm and security devices. NMM-100P NMM-100P APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterf low devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. NMM-100P OPERATION Each NMM-100P uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). NMM-100P SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum operating current: 375 pA. Maximum IDC wiring resistance: 1,500 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3° (3.302 cm) high x 2.75° (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. NZM.1 00 Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on NFW-100, 01 —99 on NFW-50. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The NZM-100 Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. NZM-100 APPLICATIONS Use the NZM-100 to monitor a zone of two-wire smoke detec- tors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resis- tance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. NZM-100 OPERATION Each NZM-100 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). NZM-100 SPECIFICATIONS Nominal operating voltage: 1510 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Maximum operating current: 270 pA (LED flashing). EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% 1093% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4° (10.16 cm) wide x 1.25° (3.175 cm) deep. Mounts to a 4' (10.16 cm) square x 2.125° (5.398 cm) deep box. NDM.1 00 Dual Monitor Module The NDM-100 Dual Monitor Module is intended for use in intel- ligent, two-wire systems. It provides two independent two-wire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or normally closed security devices. The module has a single panel-controlled LED. NOTE: The NDM- 100 provides two Class B (Style B) IDC circuits ONLY Class A (Style Q) IDC circuits are NOT supported in any application. NDM-100 SPECIFICATIONS Normal operating voltage range: 151032 VDC. Maximum current draw: 6.4 mA (LED on). Maximum operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. EOL resistance: 47K ohms. Temperature range: 320 to 120°F (00 1049°C). Page 2 of 6 - dn-6999:a ° 04/28/08 Ctj CAUTION DE-ENERGIZE UNIT PRIOR TO SERVICING - Face plate for NMM-100, NZM-100, and NDM-100 Mounting Diagrams for Standard-sized Modules ID Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125" (5.398 cm) deep. NDM-100 AUTOMATIC ADDRESSING The NDM-100 automatically assigns itself to two addressable points, starting with the original address. For example, if the NOM-100 is set to address "26", then it will automatically assign itself to addresses '26" and "27". NOTE: "Ones" addresses on the NDM- 100 are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation NMM-100, NZM-100, and NDM-100 modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 sur- face-mount box. Mounting hardware and installation instruc- tions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. The NMM-100P module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 FM Approved CSFM: 7300-0028:230 (NMM-100, NMM-100P, NZM-100); 7300-0028:237 (NDM-1 00) MEA: 72-01-E Vol. II (NMM-100, NMM-100P, NZM-100): 227-03-E Vol. III (NDM-100) Product Line Information NMM-100: Monitor module. NMM-100P: Monitor module, miniature. NZM-100: Monitor module, two-wire detectors NDM-100: Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. Architects/Engineers' Specifications Specifications of these and all FireWarden-compatible prod ucts are available from Notifier. dn-6999:a • 04/28/08 - Page 3 of 6 Wiring Diagrams The following wiring diagrams are included: NDM-100: Typical dual two-wire Style B initiating device circuit configuration. NMM-100P: Typical two-wire Style B initiating device circuit configuration. NMM-100: Typical two-wire initiating circuit configuration, NFPA Style B. N1v1M-100: Typical four-wire fault-tolerant initiating circuit configuration, NFPA Style D. NMM-100: Typical two-wire initiating circuit configuration for security systems (with alarm versus short capability). NZM-100: Interface two-wire conventional detectors, NFPA Style B. NZM-100: Interface two-wire conventional detectors, NFPA Style D. Applications with Conventional Detectors: Resetting Conventional Detectors Figure 1 NDM-100: Typical dual two-wire Style B initiating device circuit configuration. Two Initiating Device Circuits FROM Panel each power-limited 10 Device or Previous 230 UA max. © 12 VOC max. MONITOR I+ Device Communication MODULE R sistor 47K EOL Line 2 VDC maximum. ELR-47K e Twisted-pair is All shown wiring is supervised and power Resistor ' commended: ~EG 47K EOL limited. AOI1CSS Connect modules to listed compatible Nob. ELR-47K lire FireWarden control panels only. ANY NUMBER of UL Listed contact closure devices may be used. - DO NOT MIX fire alarm initialing. supervisory. or security devices on the same circuit. - Install contact closure devices per manufacturers installation instructions. 6822wi,I.wmi Figure 2 NMM-IOOP: Typical two-wire Style B initiating device circuit configuration r'----- TO - NEXT /j DEVICE BLACK UL LISTED H I_ RED J Miniature M0nitoiiii Compatible 6789 56789 Control Panel I 2 I 5 10 2)'13 I 101514 1 0 UIELLOW VIOLET h 47K EOL INCLUDED 5e720w1,1.wm1 0 Page 4 of 6 - dn-6999:a • 04/28108 NOTE: Wiring Diagrams this Page: NMM-100 Connect modules to listed compatible Notifire FireWarden • Any number of UL-listed contact closure devices may be control panels only. used. All wiring shown is supervised and power limited. • DO NOT MIX fire alarm initiating, supervisory, and secu- Install contact closure devices per manufacturers' installa- rity devices on the same circuit. tion instructions. Figure 3 NMM-100: Typical two-wire initiating circuit configuration, NFPA Style B. TO Next FROM Panel Device or Previous MONITOR Device Initiating Device Circuit (IDC) MODULE NFPA Style B. power limited: "Communication Line Twisled.pair is recommended. 47KE0L ii 1+1 1+1 riiIJ Resistor ELR-47K 5 ---- Communication Loss (optional connection for panels which support this feature) IF ESJ FUTURE FEATURE e720wa2.wm1 Figure 4 NMM-100: Typical four-wire fault-tolerant initiating circuit configuration, NFPA Style D. TO Next — FROM Pane! Device or Previous MONITOR Device MODULE Communication Line 32 voc maximum. Twisted-pair is recommended. EOL Resistor wm 20 is internal at terminals 8 & 9 Communication Loss (optional connection for panels which support this feature) FUTURE FEATURE e720wi,3.wuuu1 Figure 5 NMM-100: Typical two-wire initiating circuit configuration for security systems (with alarm versus short capability). TO Next Device t—) FROM Panel Initiating Device Circuit (IOC) 1+) or Previous NFPA Style B. power limited: MONITOR Device 230 pA max. @ 12 voc max. MODULE Communication Line 14K Series Resistor Ok 32 voc maximum. Twisted-pair is recommended. 47KEOL Resistor Communication Loss ELR-47K exunrss (optional connection for panels 0 which support this feature) FUTURE FEATURE 5720w1r4.wn,I dn-6999:a • 04/28/08 — Page 5 of 6 NOTE: Wiring Diagrams this Page: NZM-100 and NC-100R Connect modules to listed compatible control panels only. Detectors must be UL listed compatible with module. Terminal wiring must be power limited. Install detectors per manufacturers installation instructions. DO NOT MIX fire alarm initiating, supervisory, and secu- Power to the interface module must be externally rity devices on the same circuit. switched to reset the detectors. An relay control module DO NOT LOOP wire under terminals. Break wire run to can be used to switch power from a standard power sup- provide supervision of connections. ply; see Figure 8 below. Figure 6 NZM-100: Interface two-wire conventional detectors, NFPA Style B. TO Next Device + FROM Panel (4 or Previous INTERFACE MODULE Device Communication Line 32 VDC maximum. Twisted-pair is recommended. 3.9K EOL Backup + switched witched (included) LflCW 4 AOORCSS power supply. A2143.10 o 9 Optional Branch Circuit TO Next Interface Module Module supervises supply voltage and detector loop. 6720w1's.wvt Figure 7 NZM-100: Interface two-wire conventional detectors, NFPA Style D. - FROM Panel TO Next + (+) or Previous Device Device INTERFACE Communication Line MODULE 32 voc maximum. Twisted-pair is !ll recommended. + Listed BatteryBackup + switched DC power supply. Optional Branch Circuit ext Interface Module Next Module supervises supply voltage and detector loop. 6720w,6.wm1 Figure 8 Applications with Conventional Detectors: Resetting detectors NOTE: To reset conventional detectors, externally switch off power to the interface module they are connected to. This example shows NC- IOOR (see separate data sheet). TO Next FROM Panel Device or Previous RELAY Device CONTROL DC POWER MODULE SUPPLY Listed for Fire Comm unication Line 01 : Protection with - Twisted-pair is Battery ' recommended. 6720w1r7.wm1 Notifier® and FireWarden® are registered trademarks of Honeywell International Inc. 02008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. -----.----------- This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. 93=11=1 ________ ______ I lGlNHBlNC & KNIIEKTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 6 of 6 - dn-6999:a • 04/28/08 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:230 Page 1 of I CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Notifier, 12 Clintonville Rd, Northford CT 06472 Contact: Lawrence Flood (203) 484-1200 Fax (203) 484-7309 DESIGN: Models NMM-100P, NMM-100, and NZM-100 monitor modules; Models NC-100R and NC-1 00 control modules. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units: Refer to listee's Installation Instruction Manual for details. XLF: 7300-0075:185 CAL 10-20-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or . recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 12, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division ON-60383:A NC-IOOR NOTI Fl E R' Relay Module for FireWarden Series Panels by Honeywell 11 1 General The NC-100R Addressable Relay Module provides NOTI- FIER's FireWarden Series intelligent control panels with two isolated sets of Form-C dry-contact outputs for activating a variety of auxiliary devices, such as fans, dampers, door hold- ers, control equipment, etc. Addressability allows the dry con- tact to be activated, either manually or through panel programming, on a select basis. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady when activated. High noise immunity (EMF/RFl). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct Decade entry of address: 01 - 99 with the FireWar- den-100-2 and 01 —50 with the FireWarden-50. Applications The NC-100R may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address setting. The NC-1 OOR provides two Form-C dry contacts that switch together. Operation Each NC-100R uses one of the addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status. The LED blinks with each poll received. On command, it activates its internal relay. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel. NC-100R Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED). Average operating current: 230 liA direct poll (CLIP mode), 255 IA group poll with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125 (5.398 mm) deep box. Relay Contact Ratings Load Description Application Maximum Current Voltage Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (L/R=5ms) Coded 30 VDC 0.5 A Inductive (UR=2ms) Coded 30 VDC 1.0 A Inductive (PF=0.35) I Non-Coded 125 VAC I 0.5A DN-60383:A ° 11/25/08 - Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL Listed: S635. CSFM approved: file 7300-0028:230. FM approved. MEA approved: file 72-01-E, Vol. II. Product Line Information NC-100R: Intelligent addressable relay module. SMB500: Optional surface-mount backbox. NOTE: For installation instructions, see document 156-2593-001 and refer to the SLC Wiring Manual, document 52304. NOTIFIER® is a registered trademark of Honeywell International Inc. 02008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. I SO 9001 - d We cannot cover all specific applications or anticipate all requirements. EIIIIIINEERIND & KMOFACTUMNI All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 - ON-60383:A • 11/25/08 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL. FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE DESIGN: RATING INSTALLATION: MARKING: APPROVAL XLF 7300-0028:230 Page 1 of 1 Misc. Devices/Control Unit Accessories Notifier, 12 Clintonville Rd, Northford CT 06472 Contact: Lawrence Flood (203)484-1200 Fax (203) 484-7309 Models NMM-1000, NMM-100, and NZM-100 monitor modules; Models NC-100R and NC-100 control modules. Refer to listee's data sheet for additional detailed product description and operational considerations. 15-32 VDC In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 7300-0075:185 10-20-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims: This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 12, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division NOTIFIER® by Honeywell May 9, 2005 DN-7006 • A1-340 ND-100 and ND-100R Low-Flow Photoelectric Duct Smoke Detectors for FireWarden-100 Section: Addressable GENERAL ND-100 and ND100R photoelectric duct smoke detectors are used exclusively with the NOTIFIER FireWarden-100 (NFW- 100) addressable control panel. They provide low-flow tech- nology that enables duct smoke detection throughout a broad range of airflow environments in HVAC applications. The low- flow technology can detect smoke at air speed velocities of 100 feet per minute (0.5 m/sec) or greater, while continuing the same reliable performance to 4,000 feet per minute (20.32 m/sec). The intelligent low-flow duct detectors sample air cur- rents passing through a duct and gives dependable perfor- mance for shutdown of fans, blowers, and air conditioning systems, preventing the spread of toxic smoke an fire gases through the protected area. ND-100 and ND-100R provide a remote alarm output for use with auxiliary devices, such as the RA400 remote LED annun- ciator, as well as remote test capability with the RTS451 or RTS451 KEY Remote Test Stations. The ND-100R features a Form-C relay. APPLICATIONS Duct smoke detectors have specific limitations, they are: NOT substitute for open area smoke detectors. NOT substitute for early warning detection. NOT a replacement for a building's regular fire detection system. Please call NOTIFIER for a copy of System Sensor's applica- tion guide, Proper Use of Smoke Detectors in Duct Applica- tions, (A05-1004-00). FEATURES Air velocity rating from 100 to 4,000 feet per minute (0.5 to 20.32 m/sec). Patented telescopic sampling tube. Easily accessible code wheels for addressing detector. Outside mounting tabs. Mounts to round or rectangular ducts from 1' to 12' (0.3 to 3.7 meters) wide. Transparent cover for convenient visual inspection. Powered outputs for remote LED, and remote test and sounder. Two Form-C auxiliary contacts (ND-100R). Patented cover-tamper trouble signal. ND-100R requires both com line power and one of the following: 24 VAC/VDC or 120/220 VAC for operation. INSTALLATION Refer to installation manuals for control panel and duct detector for detailed information or to install equipment. Wiring: For signal wiring (the wiring between detectors or from detectors to auxiliary devices), it is recommended that single conductor wire be no smaller than 18 AWG (0.78 mm2). 1.I California State Fire UL M EA Marshal 320-02-E Vol. Il 3240-0028:232 LISTED 3240-0028:236 S635 MARYLAND (ND-100) State Fire Marshal Permit # 2173 (NO-100R) ND-100 AID-100i The duct smoke detector terminals accommodate wire sizes up to 12 AWG (3.1 mm2). Flexible conduit is recommended for the last foot (30.48 cm) of conduit; solid conduit connections may be used if desired. Smoke detectors and alarm system control panels have speci- fications for Signaling Line Circuit (SLC) wiring. Consult the control panel specifications for wiring requirements before wiring the detector loop. The ND-100 and ND-100R detectors are designed for ease of wiring; their housing provides a ter- minal strip with clamping plates. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. IS09001 For more information. contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 NOTI Fl E R ENGINEERING & MANUFAC1URING by Honeywell 12 Clintonville Road, Northford, Connecticut 06472 QUALITY SYSTEMS DN-7006 • 05/09105— Page 1 01 4 SPECIFICATIONS ND-100 Operating voltage range: 15 to 30 VDC. Standby current: 300 pA © 24 VDC (one communication every 5 seconds with LED blink enabled). Operating temperature range: 32° to 13 1°F (0° to 550C). Operating humidity range: 10% to 93% relative humidity (non- condensing). Storage temperature range: —22°F to +158°F (-30°C to +70°C). Duct air velocity: 100 to 4000 feet/mm (0.5 to 20.32 mIs). Shipping weight: 3.35 lbs. (1.5 kg). Dimensions: 14.75° (37 cm) length x 5.50 (14 cm) width x 2.75" (7 cm) deep. ND-100 accessory current loads @ 24 VDC PA400: refer to PA400 data sheet DN-2405. RA400Z: 0 mA standby, 10 mA maximum in alarm. RTS451 and RTS451 KEY: 0 mA standby, 7.5 mA maximum in alarm. ND-100111 Operating voltage range: 20 to 30 VDC, 24 VACNDC, 120/ 240 VAC auxiliary power (requires a separate auxiliary source). Standby current: 300 pA 0 24 VDC (one communication every 5 seconds with LED blink enabled). Operating temperature range: 320 to 131°F (00 to 550C). Operating humidity range: 10% to 93% relative humidity (non- condensing). Storage temperature range: —22°F to +158°F (-30°C to +70°C). Duct air velocity: 100 to 4,000 feet/mm (0.5 to 20.32 mIs). Shipping weight: 3.90 lbs. (1.8 kg). Dimensions: 14.75° (37 cm) length x 5.50° (14 cm) width x 2.75" (7 cm) deep. RA400Z RTS451 RTS451KEY ND-100R contact ratings Alarm auxiliary contacts* (DPDT): 10A@30VDC. 10 A 0 277 VAC (0.75 power factor). 240 VA © 249 VAC (0.4 power factor). 1/8HP@12OVAC. 1I4HP@24OVAC. Supervisory contact (SPST): 2.0 A © 30 VDC (resistive). Minimum switching current for auxiliary contact must be 100 mA DC minimum 0 5 VDC. ND-100R accessory current loads @24 VDC PA400: refer to PA400 data sheet DN-2405. RA400Z: 0 mA standby, 12 mA maximum in alarm. RTS451 and RTS451 KEY: 0 mA standby, 10 mA maximum in alarm. See table below for ND- 100R current requirements. PRODUCT LINE INFORMATION ND-100 Addressable low-flow duct detector housing with photoelectric smoke detector. ND-100R Addressable low-flow duct detector housing with photoelectric smoke detector with DPDT relay. A5053FL Replacement photoelectric sensor board. A5067 Replacement power board (without relay). A5060 Replacement power board (with relay). ST-1.5 Metal sampling tube, duct widths 1' to 2' (sec table on page 3 for metric lengths). ST-3 Metal sampling tube, duct widths 2' to 4'. ST-5 Metal sampling tube, duct widths 4' to 8'. ST-1 0 Metal sampling tube, duct widths 8' to 12'. RA400Z Remote annunciator alarm LED. RTS451 Remote test station. Mounts in single-gang box. Includes red alarm LED and magnet test switch. RTS451 KEY Key-activated remote test station. F36-09-11 Replacement filters. M02-04-00 Replacement test magnet. S08-39-01 Replacement photo insect screen. P48-61 -00 Replacement end cap for plastic sampling tube. P48-21-00 Replacement end cap for metal sampling tube. T80-71 -00 Replacement sampling tube. ND-IOOR current requirements (using no accessories) Power supply voltage 20-30 VDC 24 VAC, Hz 120 VAC, 50/60 Hz 220/240 VAC, 50/60 50/60 Hz Max. standby current 26 mA 65 mA RMS 44 mA RMS 25 mA RMS Max. alarm current 87 mA 182 mA RMS 52 mA RMS 30 mA RMS Alarm response time 3 to 10 sec. 3 to 10 sec. 3 to 10 sec. 3 to 10 sec. Power-up time 2 sec. 2 sec. 2 sec. 2 sec. Page 2 of 4 - DN.7006 ° 05109/05 ND-100 Detector Terminals >- LU w<-00.0 WIRING DIAGRAMS for ND-100 + I + I COMMUNICATION 00 00 LINE 0 C..) E 10 UL Listed Control Panel 1st Detector / \ in Loop / On to other Detectors on the Loop 2nd Detector in Loop ND-100 Duct Smoke Detector using a UL-Listed control panel S ND-100 0 Detector .- - - - -.-. Terminals I ND-100 Duct Smoke Detector with optional RA400Z COMMON TEST A ND-100 Duct Smoke Detector with RTS451/ Field-Installed RTS451 KEY JUMPER , t.) ç2) NOTE: For RTS451, Terminal 3 is not used. RTS451 does not have a Terminal 6. LED 1 RESET For RTS451KEY, Terminals 3 p and 6 are not used. RTS451/RTS45I KEY INLET TUBE SELECTION Outside Duct Width Inlet Tube* Up to 2 feet (0.6096 m) ST-1.5 2 to 4 feet (0.6096 to 1.2192 m) ST-3 4 to 8 feet (1.2192 to 2.4384 m) ST-5 8 to 12 feet (2.4384 to 3.6576 m) ST-b NOTE: Inlet tube is required and must be purchased separately. Order one inlet tube for each duct smoke detector ordered. DN-7006 • 05/09/05 - Page 3 of 4 WIRING DIAGRAMS for ND-100R ND-100R Duct Smoke Detector using a UL-Listed control panel: ' V — - \OO/ \OO \oo/ \OL) - 00 0 H 00 oLH_V D---'--- 0 fl UL-LISTED ___________________C'— CONTROL PANEL Ji JUMPER 1ST DETECTOR Ji JUMPER -' 2ND DETECTOR IN LOOP IN LOOP NOTES: 1) Jumper Ji shunt must be installed for 2-W applications. Ji shunt must be removed for power PCB supervision.. Note that removal of shunt without adding external power will prevent communications to the panel over the SLC. 2) External power of 24 V AC/DC or 120/220 VAC must be connected in order to power all remote horn or strobe accessories. COMMUNICATION LINE RA400Z DO NOT BREAK TAB ON RA400Z PA400 18 ND-I OOR Duct Smoke Detector with optional RA400Z: E Li II1 -00 5 = Alarm Signal 7 = Aux. Power (-) NO-100R Duct Smoke Detector with optional PA400: °°o[j I F E fl O 0--1 ND-I OOR Duct Smoke Detector with RTS45I/RTS45I KEY: • RTS451/ RTS451 KEY -' Ii..-.. I ALARM SIGNAL 3C) NOT USED ALARM SIGNAL NOT USED 2,-.. CIRCUIT AUX. POWER (_) REFERENCE 4 TESTT - k TEST 5 .._( SWITCH TEST - (—" FOR RTS451, TERMINAL 3 IS NOT USED. (RTS451 DOES NOT HAVE A TERMINAL 6.) FOR RTS451KEY TERMINALS 3 AND 6 ARE NOT USED. 7OO6w4.wrnI 5 = Alarm Signal 7 = Aux. Power (-) Page 4 of 4 - DN-7006 • 05/09/05 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION RATING: MARKING: APPROVAL: XLF: 3240-0028:236 Page 1 of 1 Duct Smoke Detector Housing/Base Notifier, 12 Clintonville Rd, Northford, CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 FAX (203) 484-7309 Model ND-100 Duct smoke detector. Unit consists of a housing, relay, electrical components, sampling and exhaust tubes and a listed detector head. Refer to listee's data sheet for additional detailed product description and operational considerations. In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Air velocity varies between 100 and 4000 fpm Listee's name, model number, air velocity rating, and UL label. Listed as a duct detector unit when used with listee's separately listed compatible fire alarm control units. Suitable for use in ducts where air velocity varies between 100 and 4000 fpm. Refer to listee's Installation Instruction Manual for details. 3240-1209:155 ' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. - Date Issued: JUNE 121 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division SYS TEnI1 SENsoi' Duct Smoke Detector Accessories Expand the versatility of the lnnovairR line of duct smoke detectors with System Sensor notification and test accessories. Available Accessories APA1 51 Piezo Annunciator MHR Mini-Horn, Red MHW Mini-Horn, White PS24LO Mini-Alert Add-on Strobe (red) PS24LOW Mini-Alert Add-on Strobe (white) PSI 2/24SLENSW Wall-Mount "SMOKE Lens RA400Z Remote Annunciator RTS451 Remote Test Station RTS451 KEY Remote Test Station with Key 55K45 1 Multi-Signaling Accessory Agency Listings LISTED v APPROVED \ I s 3 These products add functionality to the duct detection system by allowing quick, convenient inspections at eye level and effective audible and visible notification options. All System Sensor duct detectors and accessories are UL listed. The APA151 piezo annunciator, which replaces the APA451 with a new, improved look, provides an audible alarm signal, a red LED to indicate alarm status, and a green LED to indicate power status. It is intended for use with System Sensor 4-wire conventional duct smoke detector applications without a system control panel, to comply with NFPA 90A. The MHR and MHW SpectrAlert Advance mini-horns feature temporal or continuous tones at high and low volume settings. These horns are ideal for applications, where a small notification device is desired. Their small footprint allows mounting to single gang back boxes for aesthetically sensitive applications. The P524L0 and PS24LOW mini alert add-on strobes can be attached to the 55K451 multi-signaling accessory for visual alarm signaling. The PS12/24SLENSW"SMOKE lens is available to meet special code requirements in certain jurisdictions. The RA400Z remote annunciator is designed for both conventional and intelligent applications. The red LED provides visual indication of an alarm condition. The RT5451 and RTS451 KEY remote test stations are automatic fire detector accessories designed to test duct detectors from a more convenient location. For 4-wire detectors, the RTS45 I KEY test station features a multi-colored LED that alternates between steady green and red. For 2-wire detectors, the LED illuminates red for alarm. The 55K451 multi-signaling accessory is designed to work with System Sensor 4-wire conventional duct smoke detectors. It combines a horn feature with the key-activated test and reset functions. Green, amber, and red LEDs indicate power, trouble, and alarm conditions, respectively. 'les Specifications, Duct Smoke Detector Accessor . -'5-. t•; Voltage Regulated 24 VDC Operating Voltage 16 to 33 VDC Maximum Alarm Current 30 mA Temperature Range 0°C to 49°C (321- to 120°F) Relative Humidity 10 to 93% non-condensing Wire Gauge 12t0 18AWG Dimensions 4.6 in lix 2.9 in W xiS in D 75 77,77. .] Voltage Regulated 12 DC or FWR (Full Wave Rectified) or Regulated 74V0C or FWR Operating Voltage 8 to 33 VDC (9 to 33 VDC with Sync-Circuit' Module) Sounder Current Draw 22 mA RMS max at 8 to 17.5 Volts DC 17 mA RMS max at 8 to 17.5 Volts FWR 29 mA RMS max at 16 to 33 Volts DC 25 mA RMS max at 16 to 33 Volts FWR Temperature Range 0°C to 49°C (32°F to 1 20'E) Humidity Range 10 to 93% non-condensing Nominal Sounder Frequency 3 kHz Wire Gauge 12to18AWG Dimensions 1.6 in lix 2.9 in W x 0.15 in D Voltage 24 VDC Temperature Range 0°C to 49°C (37°F to 170°F) Wire Gauge 12to18AWG Dimensions 3.8 in H x 1.6 in W x 1.6 in D Th.s.i1iii°ii7 77 - . I Voltage Range Conventional System: 3.1 to 32 VDC Intelligent System: 18 to 32 VDC Mdxilrlurr: Ala::,: Curicitt 10 mA Dimensions 4.6 in I-I x 2.81::W x 1.3 in D 1 Power Requirements Alarm LED: 2.8 to 32 VDC, 7.5 mA max. Total Current: 105 mA max. Test Switch 10VA @32 VDC Reset Switch 10VA@32V1X — Alarm Response Time 40 seconds max. Temperature Range -.10°C 1060°C (I 4"F to 14(°F) Relative Humidity 95% non-condensing Wire Gauge 14 to 18AWG Dimensions 4.610 H x 2.75 in W 1.8 in 0 Power Requirements Power I Fl) (Green): 14 to 35 VOl. 17 mA rna Alarm LED (Red): 2.8 to 37 VDC, 7.5 mA max. Total Current: 103 mA maximum Alarm Response Time 40 seconds maximum Temperature Range —10°C to 60°C (14°F to 40°F) Relative Humidity 95% non-condensing Wire Gauge 14to18AWG Dimensions 4.6111 H x 2.15 iii W x 1.8111 L) 1 Voltage 21 VDC Power Requirements Standby: 8 mA Trouble: 16 mA Alarm without strobe: 40 mA Alarm with sriohe. 65 mA Sounder 87 d8A at ten feet - Temperature Range —10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14 to 22 AWG Dimensions 4.8 in H x 4.7 in W x 1.5 in 0 I ur Ure veiy latest pioduct specilicatiuris aiici listing iniluiiiiatiuii, pldsi. Visit the System Sensor web site at www.systemsensor.com -- ( fl•0Iee - RTS451 UL 54011 RTS4S1 KEY ULS2S22 APA1S1 UL 54011 55K451 UL S2522 J . _•°_•__'___1 w t,i i -- r •°•'• — I •.*' I I tr L1J 4 IS — RA400Z UL 52522 MHW UL 54011 MHR UL 54011 5SK451 with PS24LOW strobe and P51 2/24 LENSW in '___'••'°'\ 3825 Ohio Avenue. St. Charles, IL 60174 Phone: 800-SLNSOR2. Fax: 630-311-6495 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION MARKING: APPROVAL: NOTE: 7300-1653:110 Page 1 of I Misc. Devices/Control Unit Accessories System Sensor, Unincorporated Div of Honeywell Int'l Inc., 3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 377-6580 ext. 1185 FAX (630) 377-7245 Models RTS451 and RTS451 KEY remote test switches, and Model RTC remote test station kit. Refer to listee's data sheet for additional detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number and UL label. Listed as accessory devices for.use with separately listed compatible duct smoke detectors. Formerly 7300-0087:129; 7300-1209:129 06-17-05 . This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or ;•. recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division pp- 00 COOPER Notification Series ZRS Strobes, ZNS Horn Strobes and Series ZNH Horns SNAP~/-V- Series ZNS Description: The Wheelock Series Z notification appliances feature an easy snap on base that is designed to simplify the installation and testing of horns, strobes, and horn/strobes. The separate Series Z snap on base can be pre-wired so circuit wiring can be fully tested before the appliance is installed and before the walls are covered. Once all surrounding work is complete, the appliance can be simply installed by snaping it on the base. Shorting contacts in the base, which provide continuity for circuit testing, are permanently opened when the appliance is installed so any subsequent removal of the appliance will indicate a trouble condition on that circuit at the control panel when circuit supervision is enabled. The same base is used for all Series Z horns, strobes and horn/strobes to provide consistent installation and easy replacement of appliances if required. A locking screw is also included for the appliance to provide extra secure installation. The Wheelock Series Z appliances incorporate the same dependable circuitry and high efficiency optics that are used in Wheelock RSS strobes, NS horn/strobes and NH horns and have the same high performance ratings. The Series Z appliances are compatible with all UL listed 'Regulated" panels and all panels that are compatibility listed with Wheelock RSS, NS and NH appliances. ZNS, ZNH and ZRS appliances go onto the base plate in a SNAP. (UG L , MEA APPROVED Series ZNH Series ZRS Series ZRS Features: Approvals include: UL Standard 1971, UL Standard 464, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM) and Chicago (BFP). See approvals by model number in Specifications and Ordering Information ADNNFPNUFCIANSI and OSHA 29, Part 1910, 165 compliant EZ Mount SNAP design, with separate base plate, provides ability to pre-wire the base and test the circuit wiring before the walls are covered The base plate is protected by a disposable cover and the appliances can quickly snap onto the base after the walls are painted. Patented EZ Mount Universal Mounting Plate (ZBASE) - uses single plate for ceiling and wall mount installations Wall Mount models feature field selectable candela settings of 15/30/75/110cd and 135/185cd Ceiling Mount models feature field selectable candela settings of 15/30/75/95cd and 115/177cd Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol 12 and 24 VDC models with UL "Regulated Voltage" using filtered DC or unfiltered VRMS input voltage Strobes produce I flash per second over the "Regulated Voltage" range (ZNS, ZRS models) Selectable Continuous Horn or Temporal (Code-3) Tones with selectable 90 or 95 dBA setting (ZNH, ZNS models) Selectable 12 or 24VDC in 1 appliance (ZNH model) NOTE: All CAUTIONS and WARNINGS are identified by the symbol a. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range". All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. Series ZNS Strobe products are listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%). Series ZNH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Series ZNS Ratings Per UL Standard 1971 Input Regulated Model Voltage Voltage Strobe Candela VDC Range (CD) VDC/FWR ZNS-MCW 24 16.0-33.0 15/30/75/110 ZNS-MCWH 24 16.0-33.0 135/185 ZNS-MCC 24 16.0-33.0 15/30/75/95 ZNS-MCCH 24 16.0-33.0 115/177 lIable 3: Series ZNS UL Max. Current* Table 2: Series ZNSIZNH Horn dBA Ratings Reverberant dBA Anechoic dBA @10ftperUL464 @l0ft Description Volume 12 24 12 24 VDC . VDC VDC VDC Continuous High 83 87 89 95 Low 76 81 84 90 Horn Code 3 High 79 82 89 95 Low 72 76 84 90 Horn Audible Wall Mount Strobe Models Ceiling Mount Strobe Models Series ZNSIZNH ZNS-MCW ZNS-MCWH ZNS-MCC ZNS-MCCH 24 VDC ZNH-12124 115cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd High (95) dBA 16-33 0.044 0.074 0.107 0.184 0.244 0.350 0.477 0.082 0.124 0.209 0.275 0.350 0.477 (90) dBA 0.018 0.066 0.101 0.177 0.232 0.306 0.429 0.071 0.114 0.201 0.261 0.306 0.429 VDC r Low Audible Series ZNS!ZNH ZNH-12/24 I2VDC High (89) dBA 8-17.5 I 0.021 ILow (84) dBA I VDC 0.012 Table 4: Series ZRS UL Max. Current* ZRS 24VDC Models ZRS -Wall Mount ZRS - Ceiling Mount MCW MCWH MCC MCCH 15cd 30cd 75cd llOcd 135cd 185cd l5cd 30cd 75cd 95cd 115cd 177cd 16-33vdc 0.060 0.092 0.165 0.220 0.300 0.420 0.065 0.105 0.189 0.249 1 0.300 0.420 * IlL max current rating is the maximum RMS current within the listed Voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed Voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Wiring Diagrams"' ZNS/ZNH APPLIANCE FROM + + TO NEXT PRECEDING APPLIANCE - OR EOLR PS-12/24-8MP, - APPLIANCE, SM/DSM, PS-12/24-8CP OR FACP ! SIGNAL ZNS AND ZNH APPLIANCES SYNCHRONIZED WITH SM MOD- ULE SINGLE CLASS "B" NAC CIRCUIT WITH AUDIBLE SILEN :FEATURE SM T1- STROBE 1 r STROBI Affø Strobe Circuil Audib P EOLR -An,ih Audible NAC NOTE: ZNS/ZNH must be set on Code-3 horn tone to achieve synchronized temporal (Code-3) tone. Refer to installation instruction (1283983, P83600 respectively). 11 For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the power supplies refer to Installation Instructions P84662 for PS-24-8MC. PP(IPI(ATIflN L QRflFRIN INFORMATION Model Number Order Code Strobe Candela Sync WI SM DSM or PS-24-81VIC 24 VDC 12 VDC Mounting Options# Agency Approvals UL MEA CSFM - FM - BFP ZNS-MCW-FR 0304 .15/30/75/110 X X - B. D, E. F X * X * * ZNS-MCW-FW 0305 15/30/75/110 X X - B, D, E. F X * X * ZNS-MCWH-FR 0306 135/185 X X - B. D, E. F X * X ZNS-MCWH-FW 0307 135/185 X X - B. D. E. F X * X * * ZNH-R 0300 - X X X B. D, E, F X • X * * ZNH-W 0301 - X X X B. D. E, F X • X * ZNS-MCC-FR 0310 15/30/75/95 X X - B. D. E, F X * X ZNS-MCC-FW 0311 15/30175/95 X X - B, D. E, F X * X * * ZNS-MCCH-FR 0312 115/177 X X - B, D, E. F X * X * * ZNS-MCCH-FW 0313 115/177 X X - B, D, E. F X * X * ZRS-MCW-FR 4085 15/30/75/110 X X - B, D, E. F X * X * * ZRS-MCW-FW 0302 15/30/75/110 X X - B, D, E. F X • X * * ZRS-MCWH-FR 5242 135/185 X X - B, D. E. F X * X * * ZRS-MCWH-FW 0303 1351185 X X - B, D. E, F X * X * ZRS-MCC-FW 0309 15/30/75/95 X X - B, D. E, F X * X * * ZRS-MCC-FR 0308 15/30/75/95 X X - B, D. E, F X * X * * ZRS-MCCH-FR 5240 115/177 X X - B. 0, E, F X * X ZRS-MCCH-FW 0314 115/177 X X - B, D, E, F X * X * ZBASE 5268 Accessory - Includes base, dust cover, mounting screws and installation - - sheet ZBB-R 6036 Backbox for indoor suface mounting of all SNAP models ZBB-W 6045 Backbox for indoor suface mounting of all SNAP models reiiuuri #The ZRS. ZNS and ZNH will mount to single-gang, double-gang, 4" octal, 4" square and 3-1/2" octal back boxes. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. Notification Cooper Notification is Wheelock* (MEDCJ SAFEPATH WAV ARCHITECTS AND ENGINEERS SPECIFICATIONS General Audible/visual notification appliances shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. These appliances shall be listed under UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired) and UL Standard 464 (Fire Protective Signaling). The appliances shall use a Patented Universal EZMount backplate that shall allow mounting to a single- gang, double-gang, 4-inch square, 4' octal, or a 3-1/2" octal backbox. Two wire appliance wiring shall be capable of directly connecting to the mounting back plate. Continuity checking of the entire NAC circuit prior to attaching any audible/visual notification appliances shall be allowed. A dust cover shall fit and protect the mounting plate. The dust cover shall be easily removed when the appliance is installed over the backplate. Removal of an appliance shall result in an alarm condition by the Fire Alarm Control Panel (FACP). Strobes Strobe appliances shall produce a minimum flash rate of 60 flashes per minute (1 flash per second) over the Regulated Voltage Range of 16 to 33 VDC and shall incorporate a Xenon flashtube enclosed in a rugged Lexan lens. The strobes shall be available with two or four field selectable settings in one unit and shall be rated, per UL 1971, for up to 185 cd for-wall mounting and 177 cd for ceiling mounting. The strobes shall operate over an extended temperature range of 32°F to 120°F (0°C to 49°C) and be listed for maximum humidity of 95% RH. Strobe inputs shall. be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). Audibles and Audible/Strobe Combinations Horns and horn/strobes shall be listed for Indoor use under UL Standard 464. The horns shall be able to produce a continuous output or a temporal code-3 output that can be synchronized. The horns shall have at least 2 sound level settings of 90 and 95 dBA. Synchronization Modules When synchronization of strobes or temporal Code-3 audibles is required, the appliances shall be compatible with the Wheelock Series SM, DSM Sync Modules Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. Audibles and strobes shall be able to be synchronized on a 2-wire circuit with the capability to silence the audible if required. If the sync module or power supply fails to operate (i.e., contacts remain closed), the strobes shall revert to a non-synchronized flashrate WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY ZI000 ZNS!ZNH ZRS 12107 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:142 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Deborah Piserchia (732) 433-6001 Fax (732) 222-5607 deborah.piserchia@cooperwheelock.com DESIGN: Models NH-12124, NH-12124R, and ZNH horns and Models NS-1215W, NS-121575W, NS-2415W, NS-241575W, NS-2430W, NS-2475W and NS-241 lOW; NS4-1 215W, NS4- 121575W, NS4-2415W, NS4-241575W, NS4-2430W, NS4-2475W and NS4-241 low, NS-24MCw, NS4-24MCW, NS-24MCC, NS-24MCCH, ZNS-MCW, ZNS-MCC, ZNS- MCWH and ZNS-MCCH horn strobes. Model number may be followed by any two- alpha/numeric characters indicating lens, lettering and color. Units are synchronized or non-synchronized strobes. Models NH-12/24R, NS-24MCC, NS-24MCCH, ZNS-MCC and ZNS-MCCH are ceiling mount only. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical-Strobe Horn: 8-17.5 VDC/FWR and 16-33 VDC/FWR Horn: 8-17.5 VDC/FWR and 16-33 VDC/FWR Candela: 15=15cd, 1575=15/75cd on axis, 3030cd, 7575cd, 110=110cd (Wall) NS-24MCW, NS4-24MCW, ZNS-MCW: Selectable 15cd, 30cd, 75cd, llOcd NS-24MCC, ZNS-MCC: Selectable 15cd, 30cd, 75cd, 95cd NS-24MCCH, ZNS-MCCH: Selectable 115cd, 177cd ZNS-MCWH: Selectable 1 35cd, 1 85cd Flash rate: 60-Flashes/minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinanôes and in a manner acceptable to the authority having jurisdiction. All units are for wall mount except for *Models NH-12/24R, NS-24MCC, NS-24MCCH, ZNS-MCC and ZNS-MCCH are for ceiling mount only. MARKING: Listee's name, model number, electrical/candela rating and UL label. APPROVAL: Listed as audible and audible/visual signaling devices for use with separately listed • electrically compatible fire alarm control units. Models with strobe lights are suitable for the hearing impaired. For indoor use only except for model NH-12/24 horn. All synchronization strobes shall be used with Models SM-12/24, SMX-12/24, DSM-12/24 or DSMX-12/24 Sync Control Module (CSFM Listing No. 7300-0785:132). Refer to manufacturer's installation manual for details. NOTE: These appliances can produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. corrected 07-25-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or 4 recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JULY 25, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:141 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Deborah Piserchia (732) 433-6001 Fax (732) 222-5607 DESIGN: Synchronized or non-synchronized Strobe Lights. Models are as follows: RSS-##W RSSP-##W RSS-##C RSSP-##C RSS-##CR RSSP-##CR 2415 2415 2415 2415 2415 2415 2475 2475 2430 2430 2430 2430 241575 241575 2475 2475 2475 2475 2430 2430 *2495 *2495 *2495 *2495 24110 24110 1215 1215 121575 121575 Also, Models RSS-24MCW and RSSP-24MCW, RSS-24MCC, RSS-24MCCR, RSSP- 24MCC, RSS-24MCWH, RSS-24MCWHR, RSSP-24MCWH, RSS-24MCCH, RSS- 24MCCHR, RSSP-24MCCH, *ZRS..MCC *ZRS..MCW *ZRSMCCH and *ZRSMCWH. Model numbers may be followed by any two alpha/numeric character indicating lens orientation, lettering and color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical 12 = 8-17.5VDC/FWR OR 24 = 16-33VDC/FWR Candela 15=5cd, 1575=15/75cd on axis, 30=30cd, 75=75cd, 110=110cd (Wall) RSS-24MCW, RSSP-24MCW, *ZRS MCW: Selectable 1 5cd, 30cd, 75cd orll0cd . RSS-24MCC, RSS-24MCCR, RSSP-24MCC, *ZRS.MCC: Selectable 15cd, 30cd, 75cd and 95cd RSS-24MCWH, RSS-24MCWHR, RSSP-24MCWH, *ZRS..MCwH: Selectable 135cd, 185cd RSS-24MCCH, RSS-24MCCHR, RSSP-24MCCH, *zRS..MCCH: Selectable 115cd, 177cd Flash rate 60 flashes/minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models with suffix -W, wall mount only. Models with suffix -C, ceiling mount only. All models are for indoor use only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe light suitable for the hearing impaired when used with separately listed electrically compatible fire alarm control units. For synchronization strobes, Models SM- 12/24, SMX-12/24, DSM-12/24 or DSMX-12/24 Sync Control Module (CSFM Listing No. 7300-0785:132) must be used. Refer to listee's Installation Instruction Manual for details. Rev. 12-13-20061w This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or '4 recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 30, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division UUUPI( NotlTlcatlon Weatherproof Appliances - Series AH Audibles, AS Audible Strobes, MT Multitone Strobes, RSS Strobes and ET70 Speaker Strobes and Weatherproof Mounting Accessories Description: Designed for life safety, performance and reliability, Cooper Wheelock's cost effective weatherpoof notification appliances include: Weatherproof Appliances Series Strobes RSSWP Horn Strobes ASWP Horns AH-24WP, AH-12WP Multitone Horn Strobes MTWP Multitone Horns MT Speaker Strobes ET70WP Speakers ET-1010 All strobe models are UL dual listed - meeting both UL1638 and UL1971 requirements. As dual listed appliances, these weatherproof strobes, horn strobes and speaker strobes are listed for outdoor applications under UL 1638 as well as under UL 1971, the Standard for Safety Signaling Devices for Hearing Impaired. With an extended temperature range of —31°F to 150°F (-40°C to 660C), Wheelock weatherproof appliances meet or exceed UL outdoor test requirements for rain, humidity and corrosion resistance while providing multiple strobe intensity options, including the highest strobe ratings available for area coverage per NFPA 72 strobe spacing tables (up to 185 candela for wall mounting and 177 candela for ceiling mounting). To enable weatherproof mounting, Cooper-Wheelock provides the industry's widest choice of mounting options for surface or unique semi-flush installation. Models are available for surface mounting to Wheelock weatherproof backboxes on walls or ceilings. The optional WP-KIT allows the weatherproof backboxes (lOB, WPBB or WPSBB) to be mounted to a recessed electrical box for concealed conduit installation. For semi-flush installation, the WPA and WFPA kits allow a customer to mount the weatherproof appliances to a recessed electrical box without the need for an external weatherproof backbox. See the Backboxes, Plates and Gaskets Table on page three of this document for a summarization of these mounting options and the required accessories. M. EA " APPROVED 05946 151-92-E 7125-0785:131 (ASWP) S5391 7125-0785:146 (ET70WP) S2652 7125-0785:156 (MTWP) 7300-0785:154 (RSSWP) All models may be synchronized using the Wheelock SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. The horn output of horn strobes can be independently controlled on 2-wire circuits using the Wheelock patented sync protocol. MTWP horn strobe models are 4-wire appliances; the strobes can be synchronized while the audible can be connected to a coded fire alarm system or can be set to produce any of eight selectable tones. Features: Approvals include: UL Standards 1971, 1638, 464 and 1480 California State Fire Marshal (CSFM) and New York City (MEA), Factory Mutual (FM) and Chicago (BFP). See agency approvals by model number on page two of this document Compliance with the following requirements: NFPA, UFC, ANSI 117. 1, OSHA Part 29, 1910.165, ADA Weatherproof with extended temperature range of —40°F to 150°F (-40°C to 660C)* Dual Listed strobe models (UL 1638 and UL 1971) Industry's highest strobe candela options Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol Models with field selectable tone, dBA and candela settings Wall or ceiling mounting options Surface of semi-flush mounting IN/OUT wiring termination accepting two #12-18 AWG wires at each terminal The series RSSWP, ASWP, MTWP and ET70WP have UL approval down to -40F. The AH-24WP, MT-12/24 and the ET-1010 have been ULC tested and approved to -40F, but not submitted to UL. The AH-1 2VVP has UUULC approval to -31°F. NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their UL Listed Regulated Voltage Range. All candela ratings represent minimum effective Strobe intensity based on UL Standards 1971 and 1638 as indicated in candela ratings table. Wall Mount Ceiling Mount Wall or Ceiling Mount RSSWP MTWP RSSWP MTWP MT AH ASWP ET7OWP ASWP ET10WP ET-1010 Strobe Order Code Strobe Order Code RSSWP-2475W-FR Red 9013 RSSWP-2475C-FR Red 4338 Audible Order Code RSSWP-2475W-FW White 3034 RSSWP-2475C-FW White 4446 AH-24WP-R Red 7416 RSSWP-24MCWK-FR Red 5161 RSSWP-24MCCH-FR Red 5167 AH-12WP-R Red 7415 RSSWP-24MCWH-FW White 5165 RSSWP-24MCCH-FW White 5187 Horn Audible Strobe Audible Strobe MT-12/24-R Red 5023 ASWP-2475W-FR Red 9012 ASWP-2475C-FR Red 4251 ASWP-24MCHH-FR Red 5137 ASWP-2475C-FW White 4502 Speaker ASWP-24MCWH-FW White 5140 ASWP-24MCCH-FR Red 5149 ET-1010-R Red 3135 Multi-tone Strobe ASWP-24MCCH-FW White 5157 ET-1010-W White 3137 MTWP-2475W-FR Red 8420 Multi-tone Strobe MTWP-2475W-FW White 3112 MTWP-2475C-FR Red 4457 UL Max. currentT AH MTWP-24MCWH-FW White 5134 MTWP-24MCCH-FR Red 5102 High (99) dBA 24 vDcTi2 bE MTWP-24MCWH-FR Red 5132 MTWP-2475C-FW White 4478 _____________________________ 0.080 0.192 Speaker Strobe MTWP-24MCCH-FW White 5122 Med (95) dBA I 0.043-t- 0.108 1 ET70WP-2475W-FR Red 9077 Speaker Strobe Low (90) dBA 0.0211 0.058 ET70WP-2475W-FW White 3179 ET70WP-2475C-FR Red 4452 ET70WP-24185W-FR Red 4885 ET70WP-2475C-FW White 4454 UL Reverberant dBA © 10 Feet ET70WP-24185W-FW White 4891 ET70WP-24177C-FR Red 4845 watts [1/8 1114 1/2 I 1 2 4 8 ET70WP-24135W-FW White 4875 ET70WP-24115C-FR Red 4550 ET1010 177 i 8f '9"2'' I ET7OWP-24135W-FR Red 4872 ET7OWP-24177C-FW White 4859 ET70WP-24115C-FW White 4732 ET70WP [1L_8!. 84 871 90i 3i.5i Candela Ratings Series - UL 1971 UL 1638 © 77°F UL 1638 @ -40°F RSS. ET70WP and MTWP UL Max Current (Strobe Only) _____ High I 1 ASWP ______ Med - Low 2475 . 30° 180 115 0.138 0.168 0.155 0.150 MCWH -r135 185 135 56 0.300 0.355 0.340 0.335 185 77 0.420 0.480 0.465 0.460 L 115 115 47 0.300 0.355 0.340 0.335 MCCH 177 177 73 0.420 0.480 0.465 1 0.460 24185 185 185 77 0.420 **Wall mount rating only 24177 177 177 73 0.420 IL Max. Current Audible) BA lorn tell MTWP/MT 24 VOC HI STD 0.108 0:044 0.053 0.024 MT 12 VDC HI 0.177 STD 0.034 0.095 0.020 arch Time 0.104 0.091 0.075 0.0981 0.104 0.038 0.142 0.034 ode 3 Horn 0.035 0.142 0.034 ode 3 Tone 1 0.035 1 0.105 0.021 Slow Whoop Siren 0.037 10.142 0.035 0.036 0.152 0.030 Hi/Lo J.0.057 1 0.025 1 0.114 0.026 Model Number Agency Approvals - Strobe UL MEA CSFM FM BFPi RSSWP-2475 X X j X X. RSSWP-24MCWH X • X * RSSWP-24MCCH X * X * Audible Strobe -- ASWP-2475 X X X . X X ASWP-MCWH X * X X * ASWP-MCCH X * Multitone Strobe MTWP-2475 X I X * X X X * * MTWP-MCWH X MTWP-MCCH X I X * HornslAudibles AH-24WP X X X - X AH-12WP T-12/24 X X X X X -Ix X X J_ Speaker Strobe T70WP-2475 X X X T70WP-185 X X . * T70WP-177 X X * T70WP-115 X ° X T70WP-135 X X Pending Mounting Accessories WFP WFPA lOB WPSBB WPBB WBB Gasket Kit WP-KIT Order Code 4486 Mounting Options: Backboxes, Plates, Gasket Kits Flush Plates WFPA-R Red 4698 Surface Mount Flush I WFPA-W White 4701 Exposed Conduit Concealed Conduit MOUflt WFP-R Red 4696 WPSBB WPSBB + WP-KIT WFP WFP-W White 4697 RSSWP Strobes Backboxes ET70WP Speaker Strobes lOB : lOB + WP-KIT WFP IOB-R Red 5046 ASWP Horn Strobes WPBB WPBB + WP-KIT WFPA 1013-W White 5047 .. .. WPSBB-R Red 9751 AHWP Horns WBB - WFP WPSBB-W White 3033 ET-161O Speakers WBB - WFP WPBB-R Red 9014 WPBB-W White 4692 MTWP Multitone Horn Strobes lOB lOB + WP-KIT WFP WBB-R Red 2959 Multitone Hrn . ...........................______________ lOB - lOB +WP-KIT WFP WBB-W White 2960 - - a Wiring Diagrams SERIES MTWP AUDIBLE APPLIANCE AND STROBE OPERATE IN UNISON. RED AND BLACK SHUNT-WIRES ARE SUPPLIED. C narJ + + TO NEXT PRECEDING -. ________ APPLIANCE PPLIANCE BLPCK -. OR EOLR DR FACP +H.0 ...........IiLC. SERIES RSSWP, ASWP, AHWP, MTWP AND MT-1 2124 APPLIANCES FROM _____________ _____ ____________ TO NEXT PRECEDING OR EOLR —fl _L11.A APPLIANCE OR FACP SERIES MTWP APPLIANCES SYNCHRONIZED STROBE OPERATION WITH CODED FACP FACP- Note: Strobe circuit requires constant voltage. SERIES RSSWP/ASWP APPLIANCES SYNCHRONIZED WI DSM MODULE SINGLE CLASS "A" NAC CIRCUIT DSMfl .;.k yi: - T Note: Models are available in Red or White. Contact Customer Service for Order Code and Delivery. #Refer to Data Sheet S7000 for Mounting Options NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. Cooper Notification is Wheelock° WIEDCJ ARCHITECTS AND ENGINEERS SPECIFICATIONS General Weatherproof notification appliances shall be UL listed for outdoor use. Weatherproof Strobe appliances shall be listed under UL Standard 1638 (Standard for Visual Signaling Appliances) for Indoor/Outdoor use and UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired). The appliances shall be available for optional wall mounting or ceiling mounting to weatherproof backboxes using either exposed conduit or concealed conduit, or semi-flush mounting to a recessed electrical box in walls or ceilings using Wheelock mounting accessories. Weatherproof Strobes Weatherproof Strobe appliances shall produce a minimum flash rate of 60 flashes per minute over the UL Regulated Voltage Range of 16 to 33 VDC and shall incorporate a Xenon flashtube. The weatherproof strobes shall be available with UL 1971 candela ratings up to 185 cd for wall mounting and 177 cd for ceiling mounting. UL 1638 candela ratings up to 180 cd at 77°F shall be available. The strobes shall operate over an extended temperature range of —40°F to 150°F (-40°C to 66°C) and be listed for maximum humidity of 95% RH. Strobe inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). Weatherproof Audibles and Audible/Strobe Combinations Weatherproof horns and multitone audibles shall be listed for Indoor/Outdoor use under UL Standard 464. The horns shall be able to produce a continuous output or a temporal code-3 output that can be synchronized. The horns shall have at least 3 sound level settings. Horn/Strobe combinations shall be able to be synchronized on a single NAC. Multitone audibles shall be able to produce 8 distinct tones selectable by dip switch and shall have at least 2 sound level settings. Multitone Audible/Strobe combinations shall have independent inputs for the audible and strobe. The strobes shall be able to be synchronized. The audibles shall be able to be coded when operated on a separate NAC. Weatherproof Speakers and Speaker/Strobes Weatherproof speakers and speaker/strobes shall be listed for Indoor/Outdoor use under UL Standard 1480. All speakers shall provide field selectable taps for 1/8W to 8W operation for either 25 VRMS or 70 VRMS audio systems and shall incorporate a sealed back construction for extra protection and improved audibility. Speakers without strobes shall be Wheelock Series ET-1010. They shall be listed to produce up to 94 dBA and shall incorporate a vandal resistant grille design. Speaker with strobes shall be Wheelock Series ET70WP. They shall be available for surface or semi-flush mounting to walls or ceilings and shall be listed to produce up to 93 dBA. Synchronization Modules When synchronization of strobes or temporal code-3 audibles is required, the appliances shall be compatible with the Wheelock Series SM, DSM Sync Modules, Wheelock Power Supplies or other. manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes and audibles shall not drift out of synchronization at any time during operation. Series ASWP audibles and strobes shall be able to be synchronized on a 2-wire circuit with the ability to silence the audible if required. The strobes on Series MT multitone audible/strobe appliances shall be able to be synchronized and shall be able to be operated on a separate circuit from the audibles while the audible circuit is connected to a coded or continuous NAC. Weatherproof Mounting Accessories Weatherproof mounting options shall include surface mounting or semi-flush mounting to walls or ceilings. Surface mounted appliances shall mount to Wheelock lOB, WBB, WPBB or WPSBB weatherproof backboxes using either exposed conduit or concealed conduit. For concealed conduit the weatherproof backbox shall be mounted to a recessed electrical box with Wheelock's WP-KIT to provide a weatherproof seal for the electrical box. Semi-flush mounted appliances shall mount to a recessed electrical box using Wheelock WFP or WFPA flush plates to provide a weatherproof seal between the electrical box and the appliance. TEtI,t# WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA S9004 WP 05/08 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:131 Page 1 of 2 CATEGORY: Fire Alarm Devices for the Hearing-Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Deborah Piserchia (732) 433-6001 Fax (732) 222-5607 DESIGN: Models AS-1215, -2415, -1230, -2430, -121575, -241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric, characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -W are for wall mount only. *Models AS-121575W and AS-241575W lens color may be white, red, blue, green, or amber. Models AS-2415C, -2430C, -2475C and -24100C audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-12WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. *Lens color may be white, red, blue, green, or amber. Models ASWP-2475W and *Aswp..2475c audible/strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Lens color may be white, red, blue, green and amber. Both models are suitable for outdoor use when mounted on the Model WPBB back box. Models AS-24MCWH, AS-24MCCH, *ASWP..24MCWH and *ASWP.24MCCH audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. Units with suffix CH are for ceiling mount only. Units with suffix WH are for wall mount only. *Lens color may be white, red, blue, green, or amber. Refer to the listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 8-17.5/16-33 VDCNFWR Flash Rate: 60 flashes/minute Candela: 15:15cd, 1575:15/75cd, 30:30cd, 75:75cd, 95:95cd, 100:100cd, 110:110cd MCW: Selectable 15cd, 30cd, 75cd, 110cd MCC: Selectable 15cd, 30cd, 75cd, 95cd MCWH: Selectable 135cd, 185cd (65cd, 90cd at -40 C) MCCH: Selectable 115cd, 177cd (50cd, 75cd at -40 C) Listing No. 7125-0785:131 Page 2 of 2 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W, ASWP- 24MCWH, AS-24MCW and AS-24MCWH are for wall mount only. Models ASWP-2475C, ASWP-24MCCH, AS-24MCCH, AND AS-24MCC are for ceiling mount only. Models with suffix - W or WH are for wall mount only. Models with suffix -c or -CH are for ceiling mount only. MARKING: Listee's name, model number, electrical/candela rating; and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-12WP, AH-24WP, *Aswp..2475w ASWP-2475C, ASWP-24MCWH, and ASWP-24MCCH audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-i 2/24, SMX-i 2/24, DSM-1 2/24 or DSMX-i 2/24 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's Installation Instruction Manual for details: These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Models AH-12, AH-24, -12WP and -24WP audible devices are not suitable for the hearing impaired applications. Rev. 10-01-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or 4• recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 26, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division FILE COPY ALARM FIRE ALARM SYSTEM RECORD OF COMPLETION Name of protected- property: - REVS & Girls Club of Carlsbad 'Ad dress: ' ' ' 2730 Bressi Ranch Way Carlsbad CA 92008 Representative of protected property (name/phone): Authority having jurisdiction: Carlsbad Fire Department Address/telephone number: 760-6024660 Organization name/phone Representative name/phone Installer iii Enterprises Supplier Notifier Service organization JJJ Enterprises Location of record (as-built) drawings: Owner Location of operation and maintenance manuals: Owner Location of test reports: Owner A contract for test and inspection in accordance with NFPA standard(s) Contract No(s): N/A Effective date: Expiration date: System Software Operating system (executive) software revision level(s): 3.01 Site-specific software revision date: Revision completed by: name (arm) 1. Type(s) of System or Service NFPA 72, Chapter 6— Local - If alarm is transmitted to location(s) off premises, list where received: - San Diego Alarm Account #0712 0 NFPA 72, Chapter 8— Remote Station Telephone numbers of the organization receiving alarm: Alarm: Supervisory: Trouble: If alarms are retransmitted to public fire service communications centers or others, indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: 0 NFPA 72, Chapter 8— Proprietary Telephone numbers of the organization receiving alarm: Alarm: Supervisory: Trouble: If alarms are retransmitted to public fire service communications centers or others, indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: 0 - NFPA 72, Chapter 8— Central Station Prime contractor: - Central station location: (NFPA 72, 1 of 4) FIGURE 4.5.2.1 Record of Completion. 2002 Edition a r. - 72-32 NATIONAL FIRE ALARM CODE Means of transmission of signals from the protected premises to the central station: 0 McCulloh 0 Multiplex 0 One-way radio o Digital alarm communicator 0 Two-way radio 0 Others Means of transmission of alarms to the public fire service communications center: System location: 0 NFPA 72, Chapter 9—AuxilIary Indicate type of connection: 0 Local energy 0 Shunt 0 Parallel telephone Location of telephone number for receipt of signals: Record of System Installation (Fill out after installation is complete and wiring is checked for opens, shorts, ground faults, and improper branching, but prior to conducting operational acceptance tests.) This system has been installed in accordance with the NFPA standards as shown below, was inspected by JJJ Enterprises on 4/8/2011 , includes the devices shown in 5 and 6, and has been in service since 4/8/2011 Z NFPA 72, Chapters I 2 3 4 5 6 7 8 9 10 11 (circle all that apply) Z NFPA 70, National Electrical Code, Article 760 Manufacturer's instructions DOther (specifr): I .4 Signed: Date: 12/29/2009 Organization: JA Enterprises 3. Record of System Operation Documentation in accordance with Inspection Testing Form, Figure 1116.2.3, is attached All operational features and functions of this system were tested by date and found to be operating properly in accordance with the requirements of: NFPA 72, Chapters 1 2 3 4 5 6 7 8 9 NFPA 70, National Electrical Code, Article 760 Manufacturer's instructions 0 Other (specify): j Signed: Organization: iii Enterprises 10 11 (circle all that apply) Date: 4/8/2011 Signaling Line Circuits Quantity and class of signaling line circuits connected to system (see NFPA 72, Table 6.6.1): Quantity: I Style: 4 Class: b (NFPA 72, 2 of 4) FIGURE 4.5.2.1 Continued 2002Edition FUNDAMENTALS OF FIRE ALARM SYSTEMS 72-33 5. Alarm-Initiating Devices and Circuits Quantity and class of initiating device circuits (see NFPA 72, Table 6.5): Quantity: 0 Style: Class: MANUAL Manual stations Noncoded I Transmitters Combination manual fire alarm and guard's tour coded stations AUTOMATIC Coverage: Complete Selective x.. -. __________ Coded __________ Addressable 7 Partial - Nonrequired Smoke detectors 3 Ion Photo 3 Addressable 3 Duct detectors 4 Ion Photo 4 Addressable 4 (C) Heat detectors 0 FT RR FT/RR RC Addressable Sprinkler waterfiow indicators: Transmitters I -. Noncoded Coded - Addressable I The alarm verification feature is disabled or enabled from seconds to seconds. (t) Other (list): 6. Supervisory Signal-Initiating Devices and Circuits (use blanks to indicate quantity of devices) GUARD'S TOUR 0 Coded stations 0 Noncoded stations 0 Compulsory guard's tour system comprised of transmitter stations and intermediate stations Note: Combination devices are recorded under 5(b), Manual, and 6(a), Guard's Tour. SPRINKLER SYSTEM Check if provided 0 Valve supervisory switches =Building temperature points 0 Site water temperature points 0 Site water supply level points Electric fire pump: ,,,Fire pump power (t) ,O,.,Fire pump running D Phase reversal Engine-driven fire pump: Selector in auto position 0 Engine or control panel trouble 0 Fire pump running ENGINE-DRIVEN GENERATOR: 0 Selector in auto position 0 Control panel trouble =Transfer switches (d)'Engine running Other supervisory function(s) (specify): (NFPA 72, 3 of 4) FIGURE 4.5.2.1 Continued 2002EdItion I V- 72-34 NATIONAL FIRE ALARM CODE Annunciator(s) Number: I Type: Serial Location: Main entrance Alarm Notification Appliances and Circuits NFPA 72, Chapter 6— Emergency Voice/Alarm Service Quantity of voice/alarm channels: 0 Single: Multiple: Quantity of speakers installed: 0 Quantity of speaker zones: Quantity of telephones or telephone jacks included in system: O - - Quantity and the class of notification appliance circuits connected to system (see NFPA 72, Table 6.7): Quantity: 5 Style: Y Class: B Types and quantities of notification appliances installed: Bells 0 With Visible Speakers 0 With Visible Horns 28 With Visible Chimes 0 With Visible Other: 0 With Visible Visible appliances without audible: 9 0 0 28 0 0 9. System Power Supplies Fire Alarm Control Panel: Nominal voltage: I20VAC Current rating: 3.0 Amps Overcurrent protection: Type: Circuit Breaker Current rating: 20 Amps Location: Electric Room Secondary (standby): Storage battery: 2 12v Amp-hour rating: 12 Calculated capacity to drive system, in hours: 24 Engine-driven generator dedicated to fire alarm system: n/a Location of fuel storage: nh Emergency system used as backup to primary power supply: n/a Emergency system described in NFPA 70, Article 700: n/a 10. Comments Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA standard(s): N/A System deviations from the referenced NFPA standard(s) are: None (signed) for service company (title) (date) (signed) for central station (title) (date) completion of the system(s) satisfactory test(s) witnessed (if required by the authority having jurisdiction): is I — I I — i'7 L I ..L.-..c- I/A n,J,l 4/1/2011 (NFPA 72, 4 of 4) FIGURE 4.5.2.1 Continued 2002Edition .. ' CARLSBAD FIRE DEPARTMENT FIRE ALARM ACCEPTANCE TESTING FRI COM_____ Business Name: CAfU5$AL &'f Ô & Address: 2736 3tZ654 _1Z4$Jt VJ'j Suite: - Zip: L// Installer Name/Company Name 41 O-T 5 Phone: 76d7't7166 Monitoring Company: 4t?J6.C.L As" m1eiUgU,_Phone: U'%'11,7i/fe? Account#_______________________________ Panel Brand/Model _A.)Pk)Z_1 W Class A (4 wire) qfj2 wire) system (circle one) System addressable N BEFORE STARTING Is" Stamped original plans and permit on site B' Non-oil based canned smoke on site 131' Ladder, volt-meter, decibel meter and all needed tools for testing on site. B'On-site test notification done (10.2.3.1) l"Call Dispatch, ask to be contacted when monitoring company notifies them of an alarm and not to tap out Fire response. Pull a pull station. IB"Place system in test mode and notify monitoring company. IB"panel secured: Key to panel in knox-box or door to FACP locked with key in knox-box. built drawings, operation & maintenance manuals provided Jo the building owner. (10.6.1.1) Adequate qualified staffing/communications provided by the installer for test (10.2.2.5) FJRE ALARM PANEL Im Visible AC power on indicator (11.6.3) Fire Alarm Panel marked listed (i.e. UL), model #, date of mfr, /lights identified.(11.11) B J-boxes for fire alarm system to be labeled "public fire alarm ,circuiV' and painted red (9.7.1.6.4.1) All FA conductors to be protected to a height of 7 feet. (NFPA 70 -760.52) "Disconnect primary dedicated line for DACT or DART. Trouble within 90 seconds? Notification to monitoring company within 4 minutes? *reconnect* (10.4.2.2) 'Disconnect secondary line for DACT or DART. Trouble within 90 seconds, Notification to monitoring company within 4 _minutes *reconnect* (10.4.2.2) Disconnect secondary power = audible or visible trouble. *reconnect* (11.6.4) 'Disconnect primary power = audible or visible trouble. *leave 1disconnected for the remainder of the test. ' Primary power is from dedicated circuit (4-7.2.5.4) "Circuit breaker labeled "FIRE ALARM CIRCUIT CONTROL" and has red lock-out or red paint? (4.4.1.4.2.2) '"FACP" signage on door to fire alarm control panel (CFC ,510.1) ' Fire Alarm Control Circuit on door of electrical panel WRemote panel (if supervised) disconnect secondary power = supervisory signal to main panel? (10.4.2.2) IT Zone/device description not just a device I.D. number (4.4.6.1) -D,Zone maps at FACP and in knox-box (4.4.6.1) l' Battery sizes match plans, adequate room for batteries, batteries dated month/year of manufacture. (4.4.1.8.1) INJTIATING DEVICES (ALL SMOKES AND PULLS TESTED) (10.4.2.2) yull stations within 5' of each exit? (5.12.7) Pull station not more than 200' travel to station? (CFC907.4.1) 11DulI station handle 3.5' to 45'above floor? (5.12.4) 'Pull station contrasts background? (A.5.12.5) "'Non-monitored system - pull station signage "LOCAL ALARM .DNLY - CALL 911" B' Pull station activation = alarm within 10 sec? (6.8.1.1) B' Pull station trouble = trouble signal? (10.4.2.2) 20TroubIe signal and restoration each within 200 seconds (4.4.3.5.1) B'Smoke detector activation = alarm within 10 sec? (6.8.1.1) OVI moke detector trouble = trouble signal? (10.4.2.2) Wct detector activation = supervisory signal? (6.15.5.3) Duct detector trouble = trouble signal? (10.4.2.2) B'Heat detector activation (simulated Ok on non-restorable only) = alarm within 10 sec? (6.8.1.1) 'Heat detector trouble = trouble signal? (10.4.2.2) ' Beam detector activation = alarm within 10 sec? (6.8.1.1) 'VESDA air sampling detectors = alarm within 120 seconds? (NFPA 76 B.3.5) ''VESDA trouble = trouble signal? (10.4.2.2) fieam detector trouble = trouble signal? (10.4.2.2) I9)Nater flow, if sprinklered = alarm within 90 sec? (5.10.2) ar Sprinkler riser tampers trouble = supervisory?(10.4.2.2) SYSTEM RESPONSE DEVICES Iff Dampers closed on activation and re-open when system ,jestored? (5.14) El HVAC shuts down on system activation? (6.15.5) eDoor unlocking devices function on activation and doors close completely (6.15.7) Er Remote annunciator panels function per design (10.4.2.2) Note: elevator function will likely be tested by the State inspector. (Documentation will suffice) tl"Elevator shunt on simulated heat actuation in elevator machine room (6.15.4) -8-Elevator recall - lobby, machine room & hoist way smoke detector activation only -61 key disabled on elevator machine room/hoist way detector activation N031F1CA110N DEVICES - Er All horn strobes function and synchronized by floor or zone J6.8.6.4.3) ' Horns at 15 db over ambient but less than 120 db; ANSI SI.4a sound meter set to 'last' response and measured at remote locations (10.4.2.2) 0 Horn strobe trouble = trouble signal to panel (10.4.2.2) &-Exterior bell or horn strobe has sign "FIRE ALARM--CALL 911" (NFPA 13 A.8.16.1) or When not electronically supervised, a sign shall be posted - "FIRE ALARM--CALL 911" adjacent to exterior notification device. tT1 &1he building address shall be clearly visible from the street, minimum 4" in height with a contrasting background for emergency response. (CFC 505.1) BEFORE ENDING Gr Full system activation for 5 minutes (15 minutes for voice 01p) on standby power. (10.4.2.2) l'nd of line resistor to be checked under full load on battery power. Voltage shall not drop more than 15% of battery rated voltage. (4.4.4) Bliotify monitoring company and occupants that test is 6 complete (10.2.3.2) Installer shall provide a report from the monitoring company ,showing the signals and times. (10.6.3) Installer shall provide the NFPA record of completion to the City inspector and to the building owner (4.5.2.1) e'Panel operating manual to be provided to building owner (CFC ,907.19) B Key to panel returned to knox-box, if applicable -0-Correction notices to include code references BORE FINALING THE PERMIT Er Confirm receipt of NFPA 72 record of completion and that it is completely filled out. ft'onfirm all noted corrections are completed. Conflrrn Monitoring Company results match test sequence MISCELLANEOUS B'Silencing instructions are not to be posted at or on the panel. (11.7.5.4) 'Audible trouble signals to be where it is likely to be heard (4.4.3.5.5) s-built drawings may be required if inspector notes significant deviations from approved plans. Approved drawings shall be provided to the owner and shall be kept with the system (10.6.1.1) 113-An audible trouble signal may be silenced but an audible ,supervisory signal may not be silenced B Remote Central Stations to be Certificated (UL Certificate, or other approved listing) (3.3.26) O1Ttest is larger than the City can handle the City inspector can require 3rd party verifier. (4.5.2.4) IThe number of supervisory devices connected to a single initiating device circuit shall not exceed 20 (6.8.5.7.2) "emote panels not mandated to monitor trouble but require 60 hours of standby power. If monitored for trouble then only ,24 hours standby power is required. (NFPA 72 annex) End of line resistor to be labeled "EOL" on device if not at the panel