HomeMy WebLinkAbout1905 CALLE BARCELONA; 120; AS110039; Permit10/21/2020 AS110039 Permit Data • City of Carlsbad 'Sprinkler Permit Permit No: AS 110039 1905 CALLE JobAddress: Status: ISSUED BARCELONA Permit Type: SPRINk Applied 3/10/2011 Parcel No: 2550120400 Approved: 3/10/2011 Lot #: 0 Reference No.: Issued: 3/10/2011 PC #: Inspector: Project Title: URBAN OUTFITTERS FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: A & D FIRE SPRINKLERS, INC. 2ND FLOOR • 11465 WOODSIDE AVE SANTEE, CA 92071 619-448-1962 Owner: • 1 FOURTH QUARTER PROPERTIES XXX L L C C/O THOMAS TROPEA 45 ANSLEY DR • NEWNANGA Fees ($) • Add'l Fees ($) Total ($) Balance ($) 130 0 • 130 0 1/1 FIRE SP;PINKL.ES INC. URBAN OUTFITTERS THE FORUM AT CARLSBAD 1905 CALLE BARCELONA, BLDG 1, STE 120 CARLSBAD, CA 92009 FIRE SPRINKLER SUBMITTALS MANUFACTURER DATA SHEETS Materials of equal design, utility, and performance may be substituted for submitted materials so as to avoid delays in the construction schedule and shall be deemed accepted by the Purchaser. IdFIUd1U prdy; uprigru, renuent dflO Kecessea renoent MODELS/S.I.N. V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N. V2704 AND V2708 QUICK RESPONSE These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pattern for standard commercial applications. They are available with either standard or quick response bulbs. The design incorporates state-of-the-art, heat responsive, frangible glass bulb design (standard or quick response) for prompt, precise operation. The die cast frame is more streamlined and attractive than traditional sand cast frames. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see chart on page 2) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides up to 3/47/19 mm of adjustments. UPRIGHT PENDENT RECESSED (V2703 AND (V2707 AND PENDENT V2704) V2708) (V2707 AND V2708) SPRINKLER OPERATION The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire, the ambient temperature rises causing the liquid in the bulb to expand. When the ambient tem- perature reaches the rated temperature of the sprinkler, the bulb shatters. As a result, the waterway is cleared of all sealing parts and water is discharged towards the deflector. The deflector is designed to distribute the water in a pattern that is most effective in controlling the fire. COVERAGE For coverage area and sprinkler placement, refer to NFPA 13 standards. S TECHNICAL SPECIFICATIONS Models/S.l.N.: V2703, V2704, V2707, V2708 Style: Pendent, Upright or Recessed Pendent ACCESSORIES ç Nominal Orifice Size: W/13 mm K-Factor: 5.6 Imp./8.1 S.l.A Installation Wrench: Nominal Thread Size: W NPT/15mm • Open End: V27 Max. Working Pressure: • Recessed: V27-2 175psi/1200kPa FM Global Finishes: • 250psi/1725kPa UL Plain brass • Factory Hydrostatic Test: Chrome plated 100% @ 500psi/3450kPa • White painted Mm. Operating Pressure: 7p5i/48kPa : Black painted** Temperature Rating: See charts on page 2 & 3 Custom painted** MATERIAL SPECIFICATIONS Proprietary nickel Teflon* coating** For cabinets and other accessories refer to Upright Deflector: Bronze per UNS C22000 separate sheet. Pendent Deflector: Bronze per UNS C51000 NOTE: Weather resistant recessed escutcheons ' Bulb: Glass with glycerin solution. Bulb Nominal Diameter: available upon request. Standard: 5.0mm Ft For K-Factor when pressure is measured in L • Quick Response: 3.0 mm Bar, multiply S.I. units by 10.0. Load Screw: Bronze per UNS C65100 * Teflon is a registered trademark of Dupont Co. Pip Cap: Bronze per UNS C65100 **UL Listed for corrosion resistance in all Spring: Beryllium nickel configurations. Exaggerated for clarity Seal: Teflon* tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 JOBIOWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect_ Para_________ Location Date Approved Date_________________________ wwW.victaulic.com 4tauIic VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. ______________ REV_H 40.10_1 FIRE PROTECTION PRODUCTS - AUTOMATIC SPRINKLERS 40.10 V27, K5.6 Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N. V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N. V2704 AND V2708 QUICK RESPONSE ½' ½' ½'Orifice Size (inches) ½' ½' 7"l ½' 13 YP. 13 3 13 13 13 Nominal IC Factor Imperial 5.6 5.6 5.6 5.6 5.6 5.6 Nominal K Factor S.I. 8.1 8.1 8.1 8.1 8.1 8.1 Standard Standard Standard ......Quick Qukk Qck d Recessed Deflector Type Upright Pendent UPendentpright Pendent Pendent Adjustment - - - up to w up to W" I. Ternperatme Ratings F'/C' by Agen 135'17/57'C 135'F/57'C ' ' ' 'F 1551/1681C oF/68C 1551168-C UL . I ilE I 360'F1182'C 360F/182'C 286 Ff141 C 286 F/141 C 286 Ff141 C - 135'F/57'C 135'F/57'C 135' -C 135'F/57'C 135'F/57'C 155:F,6rC 155'F168'C 155'F168'C 155'F/68'C 135F/57'C ULC 2 2:61/14 2 286'F/M 286'F/141'C 200 Ff93 C 360'F/182'C 360F/182'C 135'F/57'C 135'F/57'C 135'F 7' 13 'Fl 7' 135'F157'C 15 ::F F'5 ,C 1 5 C FM a 175'F/79'C 175'F/79'C 155'F/68'C 17 1 155'F168'C 200'F/93'C 200'F193'C 175'F/79'C , , , 175'F179'C 286'F1141'C 286°F1141'C 200'F/93'C 286'F1141'C 286F/141'C 200'F/93 1 C 360'F1182C 360'F/182'C 135'F/57'C 135'F/57'C 135'F/57'C 135'Ff57*C 135'Fl 7'C 155:F168:C 155F/68'C 155'F168'C 155'F/68'C 155'F/68'C 135F/57'C NYCIMEA I 62-99-E 175'F179'C 175'F179'C 175'F/79'C 286'F/141'C 286F/141'C '9C 200°F/93'C 2O0'F/93C 200'F/93'C 360'Ff182'C 360F/182'C C 286'F/141 -C 135'F/57°C 135'F/57'C 35'F/57'C 'F ' ' ' 155:F/68:C 155:F/68:C 155'F/68'C 135:F/57C CSFM I 7690-0531:112 175 Ff79 C 175 F/79C 175'F/79'C 175'Ff79'C 175'F179C • 155 Ff68 C 200 20/93 200'F/93'C 200'F/93'C I 200'F/93'C 175 Ff79 C 286 Ff141 C 286 4 286'F/141'C 286Ff141'C 286'F/141'C 200 Ff93 C _369'F/182C 360'F/182'C 135:F/57:C 135'Ff57'C 155 F/68C 135'F/57'C 155'F/68'C 135'F/57'C - LPCB . 175 Ff79 C 175'F/79'C 175'F/79'C 175'F/79'C None None I 'F 41'C 200'F/93'C 200'F/93'C 2006F/93'C 360'Ff182'C 286F/141'C 135'F/57'C 135'F/57'C 155'F/68'C . 1551/68'C 135'F/57'C 135 Ff57, C 135 Ff57 C 135'F157'C VNlIPO . 175'F/79'C 175'F/79'C 155'F/68'C 175'F/79'C i7c'F/r 155'F/68'C 200'F/93'C 200'F/93'C 175'F/79'C , , , 175'F179C 286'F/141'C 286F/141'C 200'F/93'C 'F , , I 200'F/93'C 360'F/ 182'C 286 /141 C 286 F/141 C ZSTZ ZSTX K-ZSTZ K-ZSTX ccc - 155'F/68'C 155'F/68'C None 155'F/68'C 155'F/68'C No 200'F193'C 200'F/93'C 200'F/93'C 200'F/93'C None 8 Listings and Approvals as of printing. All are approved open, except for areas designated 'No For K Factor when pressure is measured in Bar, multiply Si. units by 10.0 a FM Approved with 1/2' adjustment escutcheon only - quick response www.victaulic.com Al—c—tauliv VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 40.10_2 REV_H FIRE PROTECTION PRODUCTS - AUTOMATIC SPRINKLERS 40.10 V27, K5.6 Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N. V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N. V2704 AND V2708 QUICK RESPONSE RATINGS All glass bulbs are rated for temperatures from -67°F/-55°C to those shown in table below. dinary Identification Or 38 Part A 153/5 Orange 100 155 Ordinary C 68 38 1 Red 175 150 Intermediate E 79 Yellow 200 150 Intermediate F 93 65 Green High 1 286 27 Blue 141 10 Extra High * 360 K 300 149 Purple -$ i M I Open — No Bulb * Standard response only. All are approved open, except for areas designated No' - 150/65 if wax coated. ORDERING INFORMATION Please specify the following when ordering: S Sprinkler Model Number Style Temperature Rating K-Factor Thread Size Quantity Sprinkler Finish Escutcheon Finish Wrench Model Number S www.victaulic.com VlCTAULlC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_H t.4tauiacr 40.1O_3 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS V27, K5.6 Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N. V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N. V2704 AND V2708 QUICK RESPONSE 40.10 WARNING A Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. - Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that sup- plied by Victaulic) is not allowed. O s Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association document NFPA 25 that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that O must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: 001-610-559-3300. DIMENSIONS Standard Pendent - V2707, V2708 I 19 I 2W1 60 mm 25 mm Standard Upright - V2703, V2704 32W I 374Ih 612MW 612Mm S ½" Adjustment Recessed - V2707, V2708 (drawing not to scale) 75 MM MAXIMUM EXIENSION www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTALILIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 40.I0_4 A-0--taulia REV_H Sprinkler Type MA Recessed .V27 Open End V2707,V27O8Pendeni yes yes V2707, V2708 Recessed Pendent yes - V2703, V2704 Upright yes yes Models/S.I.N. V2707, V2708 K5.6 standard pendent and recessed pendent distribution patterns - trajectory 10.1 3.0m 4. 1.2m IT 2.4m 0 lbt - *1b, _ - - FIE c. 1'.N FIRE PROTECTION PRODUCTS - AUTOMATIC SPRINKLERS 40.10 V27, K5.6 Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N. V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N. V2704 AND V2708 QUICK RESPONSE DIMENSIONS 3/4" Adjustment Recessed - V2707, V2708 (drawing not to scale) 75 mm MAXIMUM EXTENSION AVAILABLE WRENCHES . DISTRIBUTION PATTERNS 0.6m 1.2m 1psl 48 cPa See notes on next page. 5 10 12 14 iBm 2.4m 3Am 3.7m 4.3m IS psi 30 psi 103kPa 207 kPa www.victaulic.com \Anc-tau-licr VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. @2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_H 40.I0_5 MODELS/S.I.N. V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N. V2704 AND V2708 QUICK RESPONSE DISTRIBUTION PATTERNS Models/S.I.N. V2703, V2704 K5.6 standard upright distribution patterns - trajectory 4q4 10' 12' 14' 16' 0.6m 1.2m 1.8m 2.4m 3am 3.7m 4.3m 49m ?pi •" 15 psi 30 psi 48kPa 103kPa 207kPa NOTES 1 Data shown is approximate and can vary due to differences in installation. 2 These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock automatic sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the authority having jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the perfor- mance of the sprinkler and will void all Listings, Approvals and Warranties. 3 All patterns are symmetrical to the centerline of the waterway. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 40.10 2544 REV H UPDATED 0712010 ictaulic VICTAuUC IS A REGISTERED TRADEMARK OF VICTAuLIC COMPANY. © 2010 VICTAuLIC COMPANY. ALL RIGHTS RESERVED. ______________ 40.10 117 3.0.1 8' 2.4m 6' 18m 4' 1.2m 2- 0.6m 0