HomeMy WebLinkAbout1250 CARLSBAD VILLAGE DR; ; FS150020; Permit11/3/20201 FS150020 Permit Data .•' City of Carlsbad Fixed Systems Permit Permit No: FS150020 1250 CARLSBAD Job Address: Status: ISSUED VILLAGE DR Permit Type: FIXSYS Applied 11/17/2015 Parcel No: 1561804600 Approved: 11/23/2015 Lot #: 0 Reference No.: • . • Issued: 11/23/2015 PC #: : • Inspector: Project Title: GEORGINA COLE LIBRARY INSTALLATION OF A FULLY AUTOMATIC MX-200 (HFC-227EA) FIRE SUPPRESSION SYSTEM WITH BATTERY BACKUP IN: SECOND FLOOR STORAGE ROOM #210 . Applicant: . . Owner: BRADSHAW ENGINEERING CORP • CITY OF CARLSBAD 8645 ARGENT ST . . • . • SANTEE.CA . • . PUBLIC AGENCY 619-448-4300. •• . • . . Fees ($) Add'I Fees ($) Total ($) Balance ($) 0. • 0 0 . 0 1/1 I I Bradshaw Engineering Corp. I Fire Protection Engineers and Contractors 8654 Argent Street Santee, CA. 92071 I Phone (619) 448-4800, Fax (619) 448-0535 I Project Info: I City of Carlsbad Georgina Cole Library 1 1250 Carlsbad Village Dr. Carlsbad, CA. 92011 1 Scope of Work: Installation of a FM-200 Clean Agent Fire Suppression System in I Storage Room #210. The system will utilize a MX-2002, agent release control panel for the detection and control functions. Design By: Steve Wylie 619-448-4300 steve.wyliebradshaweng.com FS150020 I I I. I I Hydraulic Flow CaIcS* I for the FM-200 Fire Suppression System I . I I I I. I I I - - - - - - - - - - - - - - .- - - - - MX DesignManager- MX200 mv flcinnMnnir - MYflfl VI A I • FX !7dR - Tvne of Installation PylteM Ty e MX200 System Pressure 360 psi Discharge Time lOs - Height above Sea Level 75 ft uideUneIStandard NFPA 2001 Er9ject Info Error Messages from Calculation__-.- Calculation finished sucessfully, no errors found by calculation software I C:/Program Files (x86)/MXDesignManagerlprj/City of Carlsbad - Georgina Cole Library.mxdm Page 1 of 3 MX DesignManager- SystemMX200 Mx DesignManager - MX200 V.1.0! MX DesignManager 1.4.1 - . UL: EX 5248 - MX 1230/MX 200 FM: 3035914-MX 1230 / 3035931-MX 200 øtintitv CitruItinn Enclosure/Enclosure Part Length Width eight Vv ] VjTVr []_LJ1 I Ày Ab I Ar [11_L..Jft1 _rf]_Ji]_ Ca Tr(min) Storag_ Room _#210/ 31 11.17 7.5 2597.02 J_8 2519.03 L1325.09 0 [15.09 7 70 185.98 Total 2597.02 78 2519.03 1 1325.09 0 .j_1325.09 I 85.98 Cnnthinr N [ Volume Diameter Valv Am Pressure Filling QuantitffAdd. AgentrFilling Portion Filling Temp. Container Part jEft31 [in] L e _-ount _[psi] _____[Ib] Factor [lb/ft3] _____[°FJ Location Temp. 889098j_ 1.836 __10 _j_ljjj__I _60 psi 86 __1 _47.25 70 70 Pinp Svstm Starting Node a g o e n g Ending Node Nominal Diameter []______ Length ______[!] Elevation Change ______[!]______ Corn onent * p C Flow Rate 8.6 [I ]_____ Starting Pressure 362.57 End Pressure 220.04 1 . 2 1" 1 0 V 8.6 220.04 .208.27 3 4 . 1" . 1" 4.5 12.17 4 0 E E 8.6 8.6 208I7 199.19 19 - 181.48 .5 1" 1 -1 E 8.6 181.48 . 10T8 - .eap.nluu I tUIIIUI Icruna . .flJlutdIuUCl '.a, IV1011ulUlUIVl, rlpc-r. '.eUlltOluIl VOIVWV, Bull- ICCO I, OlUC IOI, I lUlU I - I I • C1L1UWC Selector Valve=ZV, Selector Valve Manifold OutletZMO, Selector Valve Manifold Thru=ZMT Nnls - arting Node Discharge Quantity NómI Disc. jiI Quantity I Description 1 Part. No. I Nominal Diameter 101 Spray Angle I Orifice [in] Quantity of Orifices - Pressure [psi] Actual Discharge Time Enclosure [0/..] I flP]_I Es]______________ _!art 5 100 I 86 I CD NPT10 3 I 889040 I i 180 I 0.327 I 3 180.18 I 9.8 gp_Room_ Prosquira Rcilif Vpnt. G id lin - u e e MX Max. Allowed Enclosure Over Pressure[psf 15 Max. Allowed Negativ Enclosure Pressure [psf 15 Rel. Humidity . [%]_____________ Enclosure Volume - 2519.03 40 Pressure Relief Vent Area Calc. Concentration. Known Pressure Relief Vent Area Calc. Enclosure Over Pressure Calc. Negative Enclosure [%]____________ [ml [psf Pressure 21 - - 7.01 6 12.07 24.5 c:/Program Files (x86)!MXDesignManager!pq!City of Carlsbad - Georgina Cole Library.mxdm Page 2 of 3 -s - - - - - -. - - - - - - - - - - - - - MX DesignManager- SystemMX200 Mx DesignManager - Quantity - . 86.00 Please Select MX200 V.1.0/ Unit lb MX DesignManager Part NoJ 887745 Bill of Material 1.4.1 UL: EX 5248- MX 1230/MX 200 FM: 3035914-MX 1230 / 3035931-MX 200 Description MX200(HFC227ea) -. .00 PCs. 826758 pcs. FormJcontact LPrder pressure gauge 1.001 pcs. 912075 Hose DN 40 MX200/MX 1230 90° NPT 1.001 PCs. 889098 jContainer 52 I, 360 psi, Valve B0482-A 0N33 1.00 1.00 pcs. pcs. 887628 JClamp Order Form Jrelease for 25/5o/80I exting4ishin e MX 200IMX 1230 ______ device MX 200/1230 electrical ..........181.67t. ft Order Form Pip Sch.40A-53B ERW1"x OrderFormjElbowi"NPTANSI f.00 3.001_._PCs. pcs 889040 jNozzle "brass3 CD 180° MX 200 NPT 1 bores C:/Program Files (x86)/MXDesignManager/piCity of Carlsbad - Georgina Cole Library.mxdm . Page 3 of 3 FM-200 Clean Agent Fire System Data Sheets MX-200 FIRE SUPPRESSION SYSTEM Page 1 I Caution Labels Two caution labels are available for indicating the presence of a Minimax MX-200 suppression system. Each caution label is made of aluminum. Label must be located in areas visible to the personnel located within or near the protected areas. I Technical Data Material.......Aluminum I Thickness... .0.039 in. ACAuTION Finish.........Red THIS AREA IS PROTECTED BY AN Weight........0.26 lb. MX-200 FIRE SUPPRESSION Dimensions 9 in. x 8 in. SYSTEM. I Listings/Approvals WHEN THEE FIRE RM EVENT OF A FIRE OR IN TH AND SYSTEM DISCHARGE, I UL Listed ......... EX-5248 EVACUATE HAZARD AREA ULC Listed ....... EX-5248 IMMEDIATELY AND DO NOT FM Approved File No 3035914 pp .... . REENTER UNTIL AREA IS THOROUGHLY VENTILATED. I Shipping Assembly Part No Description SYSTEM 11ANWACTU86,11 iiit,i MESA. AZ 85215 17493 CAUTION! Do NOT re-enter until area is thoroughly ventilated 17493-S Spanish Version 17494 CAUTION! This area is protected by a MX 200 Fire Suppression system 17494-S Spanish Version ACAUTION THIS AREA IS PROTECTED BY AN MX-200 FIRE SUPPRESSION SYSTEM. IN THE EVENT OF A FIRE AND SYSTEM DISCHARGE, CAUTION MUST BE TAKEN TO AVOID EXPOSURE TO PRODUCTS OF COMBUSTION. DO NOT ENTER WITHOUT AN APPROVED SELF-CONTAINED BREATHING APPARATUS OR UNTIL AREA IS THOROUGHLY VENTILATED. SYSTEM MANUFACTURES UTINIMAX USA U.0 liii I ii Iii • U3G S OUE%TON CR. SUITS 112 MESA. AX 55215 I Minimax USA LLC ... 4030 East Quenton Dr ... Suite 112 ... Mesa, AZ 85215 Ph: 480-553-5670.. .Fax: 480-553-5701 . . . http://www.minimaxfp.com MX-200 FIRE SUPPRESSION SYSTEM Page 2. Agent Tanks (Pressurized at 360 psi (25 bar)) The agent tank assemblies are manufactured in accordance with DOT 4BW500 and includes the finished tank, shipping cap, valve assembly, and siphon tube and Pressure Gauge/Low Pressure Switch. A nameplate is adhered to the finished tank displaying the agent weight and gross weight of the complete charged assembly. Tanks are superpressurized with dry nitrogen at 360 psi (25 bar) at 70 OF (21 °C). When ordering charged tank assemblies, the quantity of agent must be ordered with tank part number hyphen agent quantity in lbs. i.e. 88 9098 - 57, quantity is in 1 lb. increments. Nominal Volume Shipping Part No. "A" . "B" Dia. Mm.. Fill (Ib) Max. Fill (lb) Empty Weight (lb) 55 lb 914146 40.8 in. 23.2 in. 10 in. 25 lb 55 lb 88 lb 130 lb 889098 65.4 in. 47.8 in. 10 in. 57 lb 130 lb 108 lb 270 lb 889100 61.4 in. 140.9 in. 16 in. 116 lb 266 lb 190 lb 370 lb 889103 74.5 in. 54.0 in. 16 in. 162 lb 369 lb 229 lb 450 lb 910508 82.0 in. 61.5 in. 16 in. 199 lb 452 lb 313 lb With Liquid Level Indicator 270 lb 914148 61.4 in. 40.9 in. 16 in. 116 lb 266 lb 210 lb 370 lb 914149 74.5 in. 54.0 in. 16 in. 162 lb 369 lb 251 lb 450 lb 1914150 182.0 in. 161.5 in. 1 16 in. 1 199 lb 1452 lb 1286 lb Technical Data Tank Material......Steel Tank Finish.......Red Nameplate.......PVC foil self adhesive Valve.......Brass Listinps/ADprovals I UL Listed ......... EX-5248 ULC Listed ....... EX-5248 FM Approved... .File No. 3035914 I Shipping Assembly See chart above I I Minimax Fire Products ... 4030 East Quenton Dr. ..Suite 112 ... Mesa, AZ 85215 Ph: 480-553-5670... Fax: 480-553-5701 ... http://www.minimaxfp.com MX-200 FIRE SUPPRESSION SYSTEM Page 4 Mounting Bracket The mounting bracket is required to properly and safely secure the agent tank assemblies to a rigid vertical mounting surface. Brackets are available for 360 psi (25 bar) and 725 psi (50 bar) agent tanks. Each size tank requires only one bracket. Size Tank Used On Shipping Assembly Part No. Radius (R) "B" Weight 130 lb..........360 psi 887628 5.3 in. 4.72 in. 3.2 lb 270 lb..........360 psi 370 lb..........360 psi 887639 8.1 in. 7.87 in. 4.6 lb 200 lb..........725 psi 350 lb .......... 725 psi 450 lb ..........725 psi Technical Data Material.......Steel Finish .......... Matt-finish or powder-coated, graphite black Listinas/Aoorovals UL Listed .......... EX-5248 ULC Listed ....... EX-5248 FM Approved. ...File No. 3035914 Shipping Assembly See chart above I+H S 2.36" Minimax USA LLC ... 4030 East Quenton Dr ... Suite 112 ... Mesa, AZ 85215 Ph: 480-553-5670... Fax: 480-553-5701... hftp://www.minimaxfp.com 14.2 MX-200 FIRE SUPPRESSION SYSTEM Page 5 Nozzles The Minimax MX-200 Fire Suppression System offers several sizes of both 1800 and 3600 agent discharge nozzles. All nozzles are manufactured in brass and are available with NPT threads. A wide range of drilled orifice sizes are available to meet any discharge rate requirement. Nozzle bores are drilled per MX DesignManager calculations. 1800 Nozzle Size Shipping Assy Part No. Orifice Diameter Mm Max. "A" "B" 1/2 in. NPT 889036 0.118 in.......0.236 in. 2.2 in. 1.1 in. I in. NPT 889040 0.118 in.......0.433 in. 12.6 in. 1.6 in. 1%in.NPT 1889044 0.118in ....... 0.709in. 3.4in. 2.2in. 3600 Nozzle Size Shipping Assy Part No. Orifice Diameter Mm Max. "A" "B" 1/2 1n. NPT 88903.7 0.118in ...... 0.197in. 2.2in. 1.1in. I in. NPT 1889041 10.118 in......0.394 in; 12.6 in. 1 1.6 in. 1V2in.NPT 1889045 10.118in ...... 0.630in. 13.4in. 12.2in. Technical Data Material.......Brass Finish..........Brass Listings/ADDrovals B UL. Listed.........EX-5248 ULC Listed ....... EX-5248 FM Approved... .File No. 3035914 Shiirning Assembly I See chart above Ordering Information I I Order nozzle part no. - orifice code (i.e. 88 9045-0.118) I Minimax Fire Products ... 4030 East Quenton Dr ... Suite, 112 ... Mesa, AZ 85215 Ph: 480-553-5670... Fax: 480-553-5701... http://www.minimaxfp.com 2,55w 5.51" MX-200 FIRE SUPPRESSION SYSTEM I l.A Page 11 I Electric Release I The 24V electric release can be used to electrically actuate the agent tank valve. An electric signal is required from the detection panel. This signal operates an internal solenoid which actuates the release mechanism. The release mechanism then opens I tank valve. Only one electric release is required on multiple tank system. The remaining tank valves are opened by agent pressure through the pilot line. Technical Data Nominal Voltage..........24VDC Nominal Current.........0.5 A lP Code .................... P65 Max. Permitted Test Current. . .20 mA Electrical Inlet........1/2 in. NPT Weight...........5.5 lb Listinas/Aoorovals I UL Listed ......... EX-5248 ULC Listed ....... EX-5248 FM Approved.. ..File No. 3035914 I Shipping Assembly I Part No. Description 9323 Release without diode I 887645 Electric release screw reset tool Note: Polarity must be observed when wiring I the release to control panel. The release will not operate if installed with reverse polarity. I Note: To reset the electric release, the reset tool Must be threaded into the base of the release until it stops. Remove the reset tool and visually inspect I the pin inside the release. If the red marking on the pin is not visual, the release has been correctly reset. I Minimax USA LLC ... 4030 East Quenton Dr ... Suite 112 ... Mesa, AZ 85215 Ph: 480-553-5670... Fax: 480-553-5701 ... http://www.minimaxfp.com 14.2 MX-200 FIRE SUPPRESSION SYSTEM I iiIIiIIiiI:'Page 19-01 2013 I Swivel Adaptor (Tank to Pipe) I The swivel adaptor is used to connect the agent tank valve outlet with the NPT piping network. Two sizes are available, 1 1/2 in. and 2 in. outlet size. I Technical Data Material.......Galvanized Steel I Weight........1 1/2 in. size 2.2 lb 2 in. size 2.9 lb I UL Listed ......... EX-5248 I ULC Listed ....... EX-5248 FM Approved. ...File No. 3035914 I Shipping Assembly , Part No. Description I 7/8"-12 UN. Valve Connection (G2) to I h/2'J NPT Pipe Connection (Gi) A=3" 17563 2 "-12 UN. Valve Connection (G2) I to 2" NPT Pipe Connection (GI) A=3 1/2" ___A_0101 Minimax Fire Products ... 4030 East Quenton Dr ... Suite 112 ... Mesa, AZ 85215 Ph: 480-553-5670... Fax: 480-553-5701 ... http://www.minimaxfp.com 14.2 MX-200 FIRE SUPPRESSION SYSTEM Page 20 Pneumatic Limit/Pressure Switch The pneumatic operated limit/pressure switch can be mounted in the agent distribution piping. Upon system discharge, the agent pressure in the piping network will actuate the switch, causing the internal electrical contacts to either open or close. This action can be used to signal alarms, turn on warning lights, cause door closures to operate, etc. Technical Data Material.........Alloy Die-cast Metal IP Rating ....... lP65 Nominal Isolation Voltage... .500V Permanent Current .... 16A Nominal Operation Current... .6A, 400 VAC Weight..................3.3 lb. Listings/Approvals UL Listed ......... EX-5248 ULC Listed ....... EX-5248 FM Approved.... File No. 3035914 I Shipping Assembly Part No. Description 6758 Pneumatic Limit/Pressure Switch 724420 US 432y-M20-2352 Replacement Limit Switch (2 Contact) 224831 US 434y-M20-2352 Replacement Limit Switch (4 Contact) I I Minimax Fire Products ... 4030 East Quenton Dr ... Suite 112 ... Mesa, AZ 85215 Ph: 480-553-5670... Fax:480-553-5701 ... http://www.minimaxfp.com I Minimax, MX-2002 I AGENT RELEASE CONTROL PANEL DATA SHEETS I 11 MX-2002(E) Agent Release Control Panel General The MX-2002 is a six-zone FACP for single and dual hazard agent releasing applications. The MX-2002 provides reliable fire detection, signaling and protection for commercial, indus- trial and institutional buildings requiring agent-based releasing. The MX-2002 is compatible with System Sensor's i3 detectors which are conventional smoke detectors that can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory 'freeze' signal when the ambient temperature falls below the detector rating of approximately 45°F (7.220C). In addition, the control panel is compatible with conventional input devices such as two-wire smoke detectors, four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices. Refer to the Minimax Device Compatibility Document for a complete listing of compatible devices. Four outputs are programmable as NACs (Notification Appli- ance Circuits) or releasing circuits. Three programmable Form-C relays (factory programmed for Alarm, Trouble and Supervisory) and 24 VDC special application resettable and non-resettable power outputs are also included on the main circuit board. The MX-2002 supervises all wiring, AC voltage, battery charger and battery level. Activation of a compatible smoke detector or any normally- open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicator, display alarm infor- mation on the panel's LCD, sound the piezo sounder at the FACP, activate the FACP alarm relay and operate an optional module used to notify a remote station or initiate an auxiliary control function. The E offers the same features as the MX-2002 but allows connection to 220/240 VAC. Unless otherwise specified, the information in this data sheet applies to both the 110/120 VAC and 220/240 VAC versions of the panels. Features Listed to UL Standard 864, 9th edition. FM Approved. Designed for agent releasing standards NFPA 12, 12A, 12B, and 2001. Disable/Enable control per input zone and output zone. Extensive transient protection. Dual hazard operation. Adjustable pre-discharge, discharge and waterflow delay timers. Cross-zone (double-interlock) capability. Six programmable Style B (Class B) IDCs (Initiating Device Circuit). System Sensor i3 series detector compatible. Four programmable Style V (Class B) output circuits - (spe- cial application power). Strobe synchronization: - System Sensor - Wheelock - Gentex - Faraday MIN-60680:A1 .06/14/2011 —Page 1 of 4 MIN-60680:A1 - Amseco Three programmable Form-C relays. 7.0 amps total 24 VDC output current. Resettable and non-resettable output power. Built-in Programmer. ANN-BUS connector for communication with optional devices (up to 8 total of any of the following): - N-ANN-80 Remote LCD Annunciator - N-ANN-I/O LED Driver - N-ANN-S/PG Printer Module - N-ANN-RLY Relay Module - N-ANN-LED Annunciator Module 80-character LCD display (backlit). Real-time clock/calendar with daylight savings time control. History log with 256 event storage. Piezo sounder for alarm, trouble and supervisory. 24 volt operation. Low AC voltage sense. Outputs Programmable for: - Releasing Circuits or NACS NACs programmable for: - Silence Inhibit - Auto-Silence - Strobe Synchronization - Selective Silence (horn-strobe mute) - Temporal or Steady Signal - Silenceable or Non-silenceable - Release Stage Sounder Automatic battery charger with charger supervision. Optional Dress Panel DP-51050 (red). Optional Trim Ring TR-CE (red) for semi-flush mounting the cabinet. Optional N-CAC-5X Class A Converter Module for Outputs and IDCs. Optional 4XTM Municipal Box Transmitter Module. Optional Digital Alarm Communicators (411, 411 UD, 411UDAC). Optional ANN-SEC card for a secondary ANN-BUS. PROGRAMMING AND SOFTWARE: Custom English labels (per point) may be manually entered or selected from an internal library file. Programmable Abort operation. Three programmable Form-C relay outputs. Pre-programmed and custom application templates. Continuous fire protection during online programming at the front panel. Program Check automatically catches common errors not linked to any zone or input point. USER INTERFACE: Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings adjustments. ANN-Bus for connection to remote annunciators. Audible or silent walk test capabilities. Piezo sounder for alarm, trouble, and supervisory. Controls and Indicators LED INDICATORS FIRE ALARM (red). SUPERVISORY (yellow). TROUBLE (yellow). AC POWER (green). ALARM SILENCED (yellow). DISCHARGED (red). PRE-DISCHARGE (red indicator). ABORT (yellow indicator). CONTROL BUTTONS ACKNOWLEDGE. ALARM SILENCE. SYSTEM RESET (lamp test). DRILL. AC Power - TB1 MX-2002:120 VAC, 60 Hz, 3.66 amps. MX-2002E: 240 VAC, 50 Hz, 2.085 amps. Wire size: minimum #14 AWG (2.0 mm2) with 600V insula- tion. Supervised, nonpower-limited. Battery (sealed lead acid only) - J12: Maximum Charging Circuit - Normal Flat Charge: 27.6 VDC @ 1.4 amp. Supervised, nonpower-limited. Maximum Charger Capacity: 26 Amp Hour battery (two 18 Amp Hour batteries can be housed in the FACP cabinet. Larger batteries require separate battery box such as the BB-26 or NFS-LBBR). Minimum Battery Size: 7 Amp Hour. Initiating Device Circuits - TB4 and TB6 Zones 1 - 5 on TB4. Page 2 of 4— MIN-60680:A1 • 06/14/2011 Zone 6onTB6. Supervised and power-limited circuitry. Style B (Class B) wiring with Style D (Class A) option. Normal Operating Voltage: Nominal 20 VDC. Alarm Current: 15 mA minimum. Short Circuit Current: 40 mA max. Maximum Loop Resistance: 100 Ohms. End-of-Line Resistor: 4.7K Ohms, 1/2 watt (PN 71252). Standby Current: 4 mA. Refer to the Minimax Device Compatibility Document for listed compatible devices. Notification Appliance and Releasing Circuit(s) - TB5 and TB7 Four Output Circuits. Style Y (Class B) or Style Z (Class A) with optional con- verter module. Special Application power. Supervised and power-limited circuitry. Normal Operating Voltage: Nominal 24 VDC. Maximum Signaling Current: 7.0 amps (3.0 amps maximum per NAC). End-of-Line Resistor: 4.7K Ohms, 1/2 watt (PN 71252). Max. Wiring Voltage Drop: 2 VDC. Refer to the Minimax Device Compatibility Document for com- patible listed devices. Form-C Relays - Programmable - TB8 Relay 1 (factory default programmed as Alarm Relay) Relay 2 (factory default programmed as fail-safe Trouble Relay) Relay 3 (factory default programmed as Supervisory Relay) Relay Contact Ratings: —2 amps © 30 VDC (resistive) - 0.5 amps 0 30 VAC (resistive) Auxiliary Trouble Input - J6 The Auxiliary Trouble Input is an open collector circuit which can be used to monitor external devices for trouble conditions. It can be connected to the trouble bus of a peripheral, such as a power supply, which is compatible with open collector cir- cuits. Special Application Resettable Power - TB9 Operating Voltage: Nominal 24 VDC. Maximum Available Current: 500 mA - appropriate for powering 4-wire smoke detectors (see note). Power-limited Circuitry. Refer to the Minimax Device Compatibility Document for com- patible listed devices. NOTE: Total current for resettable power, nonresettable power and Output Circuits must not exceed 7.0 amps. Special Application Resettable or Nonresettable Power - TB9 Operating Voltage: Nominal 24 VDC. Maximum Available Current: 500. mA (see note 1). Power-limited Circuitry. Jumper selectable by JP31 for resettable or nonresettable power. Refer to the Minimax Device Compatibility Document for com- patible listed devices. Product Line Information I MX-2002: Six-zone, 24 volt Agent Release Control Panel (includes backbox, power supply, technical manual, and a frame & post operating instruction sheet) for single and dual hazard agent releasing applications. I MX-2002E: Same as above but allows connection to 220/240 VAC. N-CAC-5X: Class A Converter Module can be used to convert I .the Style B (Class B) Initiating Device Circuits to Style D (Class A) and Style V (Class B) Output Circuits to Style Z (Class A). NOTE: Two Class A Converter modules are required to convert all four Output Circuits and six Initiating Device Circuits. 4XTM: Transmitter Module provides a supervised output for local energy municipal box transmitter and alarm and trouble reverse polarity. It includes a disable switch and disable trouble LED. N-ANN-80(-W): LCD Annunciator is a remote LCD annuncia- tor that mimics the information displayed on the FACP LCD display. Recommended wire type is un-shielded. (Basic model is black; order -W version for white; N-ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble and Supervisory. Ships with N-ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. N-ANN-RLY (16911): Relay Module, which can be mounted inside the cabinet, provides 10 programmable Form-C relays. N-ANN-S/PG: Serial/Parallel Printer Gateway module pro- vides a connection for a serial or parallel printer. N-ANN-I/O: LED Driver Module provides connections to a user supplied graphic annunciator. ANN-SEC: Optional card for a secondary ANN-BUS. See 53944. DP-51050: Dress panel (red) is available as an option. The dress panel restricts access to the system wiring while allow- ing access to the membrane switch panel. TA-CE: Trim-ring (red) is available as an option. The trim-ring I allows semi-flushing mounting of the cabinet. BB-26: Battery box, holds up to two 26 Amp Hour batteries and CHG-75. NFS-LBBR: Battery box, houses two 55 Amp Hour batteries, I red. BAT Series Batteries: Refer to DN-6933. PRN-6: UL-listed compatible event printer. Dot-matrix, tractor- fed paper, 120 VAC. PRT-PK-CABLE: Programming cable. Used to update the FACP's flash firmware. (Also requires an R5485 to RS232 converter). I I MIN-60680:A1 • 06/14/2011 -Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity useful life of the systems standby batteries and the electronic components may be adversely affected by extreme tempera- Annunciators ......................................................................8 ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment Electrical Specifications with a normal room temperature of 15— 27°C/60 - 80°F . MX-2002 (FLPS-7 Power Supply): 120 VAC, 60 Hz, 3.66 amps NFPA Standards MX-2002E (FLPS-7 Power Supply): 240 VAC, 50 Hz, The MX-2002(E) complies with the following NFPA 72 Fire 2.085 amps Alarm Systems requirements: . Wire size: minimum 14 AWG (2.0 mm2) with 600 V insula- - NFPA 12 CO2 Extinguishing Systems tion, supervised, nonpower-limited - NFPA 12A Halon 1301 Extinguishing Systems - NFPA 12B Halon 1211 Extinguishing Systems Cabinet Specifications - NFPA 72 National Fire Alarm Code for Local Fire Alarm I Door: 19.26° (48.92 cm.) high x 16.82° (42.73 cm.) wide x Systems and Remote Station Fire Alarm Systems 0.72° (1.82 cm.) deep. Backbox: 19.00° (48.26 cm.) high x (requires an optional Remote Station Output Module) 16.65 (42.29 cm.) wide x 5.25° (13.34 cm.) deep. Trim Ring - NFPA 2001 Clean Agent Fire Extinguishing Systems - (TR- CE): 22.00° (55.88 cm.) high x 19.65° (49.91 cm.) wide. Shipping Specifications Dimensions: - Height 20.00° (50.80cm) —Width 22.50° (57.15cm) - Depth 8.50° (21.59cm) Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 490C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 30F). However, the Agency Listings and Approvals The listings and approvals below apply to the basic MX- 2002(E) control panels. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. FM approved NOTE: For ULC-Iisted mode!, see MIN-60681. ©2011 All rights reserved. Unauthorized use of this document is strictly prohibited. Iso 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. !fl I I _ We cannot cover all specific applications or anticipate all requirements. ____ C4EINEEBINt & MNUMC1UNE QUALITY SYSTEMS All specifications are subject to change without notice. . Made in the U.S. A. For more information, contact Minimax, 4030 East Quenton Drive, Suite 112, Mesa AZ 85215 Page 4of4—MIN-60680:A1 °06/14/2011 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM b LISTING SERVICE LISTING No. 7165-2078:0101 Page 1 of I CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Minimax USA, LLC2814 N Norwalk Bldg. 10-119, Mesa, AZ 85215 Contact: Bill Freeman (480) 553-5670 Fax (480) 553-5701 Email: bfreeman@minimaxfp.com DESIGN: Model MX-2002 conventional fire alarm control unit. Each unit employs six programmable input circuits, four programmable output circuits, and three relay contact outputs for alarm, trouble, and supervisory signals. These units do not contain an integral digital alarm communicator transmitter (DACT). Model is intended for agent release control. FLPS-7 Power Supply module 4XTMF Transmitter module CAC-5X Converter module ANN-80 LCD Annunciator ANN-I /0 LED Driver module ANN-LED Annunciator module ANN-RLY Relay module ANN-S I PG Serial/Parallel printer module DP-51050 Dress panel DP-5105OLED Dress panel INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction: MARKING: Listee's name, product designation, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit suitable for use as agent releasing panel. Unit also provides fire detection, signaling and protection features. Refer to manufacturer's Installation Manual for details.This control unit meets the requireme'nts of UL-864, 9th Edition Standards. XLF: 7165-0075:0216 10-04-2011 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct G operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 I Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Listing Expires June 30, 2016 .3 Series Photoelectric Smoke Detectors General System Sensor's j3TM Series photoelectric and photoelectric/ thermal smoke detectors represent a significant advancement in conventional detection, incorporating three key features: installation ease, intelligence, and instant inspection. Installation ease. The P Series redefines installation ease with its plug-in design. This allows an installer to pre-wire the bases included with the heads. The large wire-entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of backbox mounting methods, as well as direct mounting with drywall anchors. To complete the installation, j3 Series heads plug into the base with a simple Stop-Drop 'N LOCkTM action. Intelligence. j3 Series detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensa- tion and smoothing algorithms, to minimize nuisance alarms, are standard in the i3 Series. When connected to the 2W-MOD loop test/maintenance module, an SFP-2402/-2404 panel, SFP-5UD/10UD, or RP-2001/2002 two-wire j3 detectors are capable of generating a remote maintenance signal when they need cleaning. This signal is indicated by LEDs located at the module and at the panel. To read the sensitivity of j3 detectors, the SENS-ROR is a wireless device that displays sensitivity in terms of percent-per-foot obscuration; Instant inspection. The j3 Series provides wide-angle red and green LED indicators for instant inspection of detector condi- tion. The LEDs indicate: normal standby, out-of-sensitivity, alarm, or freeze trouble conditions. The "EZ Walk" loop test feature is available on two-wire i3 Series detectors when con- nected to the 2W-MOD loop test/maintenance module. The "EZ Walk" feature verifies the initiating loop wiring by providing LED status indication at each detector. Features Plug-in detector line - mounting base included. Large wire-entry port. In-line terminals with SEMS screws. Mounts to octagonal and single-gang backboxes, 4° (101.6 mm) square backboxes, or directly to ceiling. Stop-Drop 'N Lock attachment to base. Removable detector cover and chamber for easy cleaning. Built-in remote maintenance signaling. Drift compensation and smoothing algorithms. Simplified sensitivity measurement. Wide-angle, dual-color LED indication. Loop testing via "EZ Walk" feature. Built-in test switch. Specifications PHYSICAL SPECIFICATIONS Operating Temperature Range: For models 2W-B and 4W- B: 32°F to 120°F (0°C to 490C); for thermal models 2WT.B and 4WT-B: 32°F to 100°F (0°C to 37.80C). Operating Humidity Range: 0% - 95% RH, non-condens- ing. DN-6885:A2 • 1-80 NOTIFIER® by Honeywell Thermal Sensor: 135°F (57.2°C) fixed (models 2WT-B, 4WT-B). Freeze Trouble: 41°F (5°C) (models 2WT-B and 4WT-B). Sensitivity: 2.50/o/foot (0.7620/o/meter) nominal. Input Terminals: Utilize 14 to 22 AWG wire. Dimensions (including base): 5.3° (134.62 mm) diameter, 2.0° inches (50.8 mm) high. Weight: 6.3 oz. (178.6 grams). Mounting Options: 3.5" (88.9 mm) octagonal backbox; 4" (101.6 mm) octagonal backbox; single-gang backbox; 4" (101.6 mm) square backbox with a plaster ring; or direct mount to ceiling. ELECTRICAL SPECIFICATIONS Operating Voltage: 12/24 V non-polarized nominal; 8.5 V minimum; 35 V maximum. Maximum Alarm Current: For two-wire models: 130 mA lim- ited by control panel; For four-wire models: 20 mA 0 12 V, 23 mA 0 24 V. Alarm Contact Ratings: For four-wire models: 0.5 A © 30 VACNDC; not applicable for two-wire models. Architectural/Engineering Specifications Smoke detector shall be a System Sensor P Series model number ________, Listed to Underwriters Laboratories UL 268 Fire Protection Signaling Systems. The detector shall be a photoelectric type (models 2W-B, 4W-B) or a combination pho- toelectric/thermal (models 2WT-B, 4W1-B) with thermal sensor rated at 135°F (57.2°C). The detector shall include a mounting base for mounting to 3.5" (88.9 mm) and 4(101.6mm) octag- onal, single-gang, and 4° (101.6 mm) square backboxes with a plaster ring, or directly mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.51/6/foot (0.7620/o/meter) as measured in the UL smoke box. The detector shall be capable of auto- matically adjusting its sensitivity by means of drift compensa- tion and smoothing algorithms. The detector shall provide dual-color LED indication which blinks to indicate power-up, normal standby, out-of-sensitivity, alarm, and freeze trouble DN-6885:A2 • 11/17/09 - Page 1 of 2 (models 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD module, two-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel, and shall provide a loop testing capa- bility to verify the circuit without testing each detector individu- ally. AgencyListings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL/ULC Listed: S911 FM Approved CSFM: 7272-1653:152 MEA: 290-01-E Maryland State Fire Marshal: Permit # 2093 LED Modes Green LED Red LED Power Up Blink every 10 seconds Blink every 10 seconds Normal (Standby) Blink every 5 seconds OFF Out of Sensitivity OFF Blink every 5 seconds Freeze Trouble OFF Blink every 10 seconds Alarm OFF Solid ON Power Up Sequence for LED Indication Condition Duration Initial LED Status Indication 80 Seconds Product Line Information 2W-B: Two-wire photoelectric smoke detector. C2W-BA: Same as 2W-B, ULC listing. 2WT-B: Two-wire photoelectric smoke detector with 135°F (57.2°C) fixed thermal sensor. C2WT-BA: Same as 2WT-B, ULC listing. 4W-B: Four-wire photoelectric smoke detector. C4W-BA: Same as 4W-B, ULC listing. 4WT-B: Four-wire photoelectric smoke detector with 135°F (57.2°C) fixed thermal sensor. C4WT-BA: Same as 4WT-B, ULC listing. ACCESSORIES: 2W-MOD2: Two-wire loop test/maintenance module. SENS-RDR: Sensitivity reader. A77-AB2: Retrofit adapter bracket, 6.6" (167.7cm) diameter. j3TM and Stop-Drop 'N LockTM are trademarks of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Iso 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. - 1 .4:b I .1 We cannot cover all specific applications or anticipate all requirements. I EfJGlNfEHlNE S MSNUfAC11lRINS QUALITY SYSTEMS All specifications are subject to change without notice. Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com - Page 2 of 2— DN-6885:A2 • 11/17/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL P FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1653:0152 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Irish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.Iinhart©systemsensor.com DESIGN: Models 2W-B, 2W1-B, 4W-B and 4WT-B photoelectric type smoke detectors. Models 2W-B and 2WT-B are 2-wire and model 4W-B and 4VVT-B are 4-wire detectors. Models 2W1-B and 4wr-B employ a thermistor type heat sensor (135°F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5 -35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct eiv operational requirements or installation criteria. Refer to listee's data sheet; installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division I =1 R " U 111 Dual Action NBG-12LR SYSTEM SYSTEM NORMAL ACTIVATED o (#) 0 TO ABORT - HOLD IN A®N R EA S- UM :oiIr dn-6840:a NBG.1 2LR and NBG- 12LRA fNoTIFIER® Dual-Action Agent Release Stations by Honeywell General The NBG-12LR and NBG-12LRA are Agent Release Stations designed for use with NOTIFIER Fire Alarm Control Panels with releasing capabilities and RP Series Releasing Systems. I Features Non-coded, dual-action operation. Made with durable polycarbonate. I . Optional surface backbox. NBG-12LRA INCLUDES: Abort switch. I .. Power-on indication. Released indication. Manual release (dual-action). NBG-12LR INCLUDES: Dual-action release only. Applications I The NBG-12LRA and NBG-12LR are ideal for areas such as clean rooms and computer rooms where a chemical agent is used to extinguish a fire. I Product Line Information NBG-12LRA: Agent release station with abort switch, Release LED, Normal LED. NBG-12LR: Dual-action agent release station. SBA-1O: Surface backbox for NBG-12LRA, metal. Dimensions 4.5" (11.43 cm) W x 8.188" (20.8 cm) Lx 1.375" (3.49 cm) D. SB-10: Surface backbox for NBG-12LR, metal. Dimensions 4.125" (10.48 cm) W x 5.5" (13.97 cm) Lx 1.375" (3.49 cm) D. SB-I/O: Surface backbox for NBG-12LR, plastic. BG12TR: Optional trim ring for semi-flush mounting. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in progress. Consult fac- tory for latest listing status. UL/ULC Listed: S692 MEA Listed: 67-20-E FM Approved CSFM: 7150-0028:0199 U.S. Coast Guard: 161.002/23/3 (AFP-200: NBG-12LRA), 161.002/42/1 (NFS-640: NBG-12LRA), 161.002/27/3 (AFP1 010/AM2020). FDNY: #6058 (NFS2-3030), #6038 (NFS2-640) ANT Dual Action NBG-12LR (shown activated) dn-6840:a • 8/4/10 - Page 1 of 2 0 Wiring I - A N.C.: System 1 Normal 24 voc: I .o.: B LED System Release Relay Operated (Green) I LED (Red) lox 1/4W 1 10K C 1/4W I 4 N.O. Abort Switch D 0 To 0 Abort I0K,1/4W Circuit E Resistors (+) 2 To Manual Release Circuit 4 10K,1/4W Resistors Mount End-of-Line Resistor on the last unit. 1ount 4.7K ELR on the last unit when abort switch and manual release switch are connected to control panel circuits. Mount 471< resis or on last unit when abort switch and manual release switch are connected to monitor module or control module. Refer to control panel nanual for the listed ELR. Refer to the product installation documentation for connection to the control panel B C I A DI jE 0 cD A o A a2 o © NotifierR and FlashScan® are a registered trademark of Honeywell international Inc. Bayblend® is a registered trademark of Bayer Corp. 02010 by Honeywell International Inc. All rights reserved Unauthorized use NBG-I2LRA (Rear view) Agent Release Pull Station of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. MOM= We cannot cover all specific applications or anticipate all requirements. UClN((RlNC & MAN VIACIUIUNC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— dn-6840:a • 8/4/10 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0028:0199 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev©honeywell.com DESIGN: Models NBG-12, NBG-12S, NBG-I2LR, NBG-I2LRA, NBG-I2LAO, NBG-I2LAOB, NBG-12-LO, NBG-I2LOB, NBG-12W, NBG-I2LW, NBG-I2NC, NBG-I2WP, NBG-I2LWP, NBG-12L, NBG-I2LX,NBG-I2LA, NBG-I2PS, NBG-I2LSP, NBG-I2LPS, NBG-I2LPSP, NBG-12SP, NOT-BGI2LX, NBG-12LXSP, NBG-12LXBL and NBG-12LXP fire alarm pull boxes. All units except Model NBG-12S are dual action pull stations. Models NBG-I2LR and NBG-I2LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product decription and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-1 2WP, NBG-1 2LW, NBG-1 2W, NBG-1 2LWP, NBG-1 2LAO, NBG-1 2L0, NBG-12LAOB and NBG-12LOB are intended for outdoor use when installed with Models WBB, SB-I/O, or WP-10 back box. Refer to listee's Installation Instruction Manual for details. These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments which the controls and operating mechanisms required to be operable at no more than 51bs. force with one hand and shall not require tight grasping, pinching, or twisting of the wrist. *Corrected 10-08-12 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division KEMRRO.M REL.EIiSINO PANEL DWOHU364 Page 21 MX-1230 FIRE SUPPRESSION SYSTEM July 2011 Abort Switch The abort switch is designed to be wired to the abort terminals of a listed releasing panel. The switch consists of a stainless steel faceplate and a modular switch assembly. It is designed to mount on a standard double gang electrical enclosure. The switch is designed for indoor use only. Technical Data Material.........Stainless steel faceplate Dimensions.. ..4 % in. W x 4 1/2 in. H x 2 in. Deep Contact Rating... .One N.O. momentary contact rated at 2.5 amps @ 24 VDC (5 mA minimum) Listings/Approvals UL Listed ULC Listed FM Approved Shipping Assembly Part No. Description 17120 Abort Switch Assembly Minimax USA LLC ... 4030 East Quenton Dr ... Suite 112 ... Mesa, AZ 85215 Ph: 480-553-5670... Fax: 480-553-5701... hftp://www.minimaxfp.com - Operation 0 RED I - SLACK The green LED indicates the RCDS _______________________________ is in the normal condition and the now . release circuit is enabled. The amber \ BLT.! LED indicates that the release circuit \\ 3LAC is disabled. VVV- !Oi ASSY RAY I D ?.fl!ASNG SOL2OD MX-200 FIRE SUPPRESSION SYSTEM Page 22 Releasing Circuit Disable Switch (RCDS-1) The Release Circuit Disable Switch (RCDS-1) consists of a stainless steel faceplate, green LED, amber LED, and switch assembly. It is designed to mount on a standard single gang electrical enclosure. The switch is designed for indoor use only. The connection for the supervisory circuit has 4 wires: 2 yellow and 2 gray. The 2 yellow wires are for connection to the supervisory circuit. The 2 gray wires are for connection to additional supervisory devices or the EOLR for the supervisory zone. Technical Data Application Material.........Stainless steel faceplate The RCDS-1 complies with NFPA 72: Dimensions.. ..2 3h in. W x 4 % in. H x 2 in. Deep - Specifying a physical switch to disconnect Contact Rating... .1 AMP @ 40 VDC the release circuit in place of a software Power Requirements .... 24 VDC, 10 mA controlled disconnect. Temperature Range ...... 22 OF to 140 OF - Creating a supervisory condition on the (-30 °C to 60 °C) associated release panel. Listings/Approvals UL Listed ULC Listed Shipping Assembly Part No. Description 17121 Releasing Circuit Disable Switch Assy Installation Connect the red and black leads to the 24 VDC auxiliary power terminals on the panel. Be certain to observe polarity. Connect the yellow wires to the supervisory zone on the panel. 24 VDC S??XiSOPY ?.!L!ASNC ZONE C!?.Ct.!T I Minimax USA LLC ... 4030 East Quenton Dr. ..Suite 112 ... Mesa, AZ 85215 I Ph: 480-553-5670.. .Fax: 480-553-5701.. I SYSTEM SENSOR f F Indoor Selectable. Output Horns, I Strobes, and 'Q Horn Strobes for Wall Applications Spectrkerl@ Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. I . Electrically Compatible with legacy SpectrAlert devices Compatible with MDL sync module Listed for ceiling or wall mounting I I Agency Listings 1 SIDNAUNG 43>MEA LISTED APPROVED approved 715-1l88 (indoor strobes) 7125-1653:188 (horn strobes. S4011 (Chimes, horn strobes, horns) 3023572 MEA452.05-E chime strobes) S5512 (strobes) 7135-1653:189 (horns, chimes) I Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12-or 24-volt operation at 15 and 15/75 candela Field-selectable candela settings on wall units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for wall units Mounting plate shorting spring checks wiring continuity before device installation The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. I SpectrAlert Advance Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/B-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.Circuit'° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and shall be approved for fire protective service. I The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6% x 4.7W x 2.5D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6% x 4.7W x 1.3D (142 mm Lx 119 mm W x 33 mm D) Wall-Mount Back Box Skirt Dimensions (BBS-2, BBSW-2) 5.9% x 5.0W x 2.2D (151 mm Lx 128 mm W x 56 mm D) Wall-Mount Trim Ring Dimensions (sold as a 5 pack) (TR-HS,TRW- 5.7% x 4.8W x 0.35'D (145 mm L x 122 mm W x 9 m D) HS) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. P. S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDSOO8O UL Max. Strobe Current Draw (n 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Standard 15 123 128 66 71 Candela 15/75 142 148 77 81 Range 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela 150 NA NA 246 220 Range 177 NA NA 281 251 185 NA NA 286 258 8-17.5 Volts 16-33 Volts Sound Pattern dB DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-temporal High 57 56 69 75 Non-temporal Medium 42 50 60 69 Non-temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 LF] DC Input 8-17.5 Volts 15 15175 16-33 Volts 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 DC Input 16-33 Volts 135 150 177 185 FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Horn 11and IHorn 1IStrobe Output (jyj I 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR Temporal High 78 78 84 84 88 88 99 98 I l 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 I Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t I Coded Low 75 75 81 81 88 85 96 92 tSettings 7, I 8, and 9 are not available on 2-wire horn strobes. AVDSOC6O1 SpectrAlert Advance Dimensions Wall-mount horn strobes Wall back box skirt SpectrAlert Advance Ordering Information IModel TIM1[.1I Wall Horn Strobes P2R°t 2-Wire Horn Strobe, Standard cd, Red P2RH" 2-Wire Horn Strobe, High Cd, Red P2W* 2-Wire Horn Strobe, Standard Cd, White P2WH* 2-Wire Horn Strobe, High Cd, White P4R" 4-Wire Horn Strobe, Standard Cd, Red P4RH 4-Wire Horn Strobe, High Cd, Red P4W 4-Wire Horn Strobe, Standard Cd, White Wall Strobes Horns HR Horn, Red HW Horn, White Accessories BBS-2 Back Box Skirt, Wall, Red BBSW-2 Back Box Skirt, Wall, White .TR-HS Trim Ring, Wall, Red TRW-HS Trim Ring, Wall White SR*t Strobe, Standard' Cd, Red I SRH*t Strobe. High cd, Red 5W' Strobe, Standard Cd, White SWH Strobe, High Cd, White I Notes: - Add '-P" to model number for plain housing (no "FIRE" marking on cover), e.g., P28-P. I Add "-SF' to model number for "FUEGO' marking on cover, e.g., P2R-SP. I "Standard Cd" refers to strobes that include 15, 15/75,30,75,95, 110, and 115 candela settings. "High Cd' refers to strobes that include 135. 150. 177, and 185 candela settings. 02012 System Sensor. $" SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 °s$ SENSOR' Phone: 800-SENSOR2 • Fax: 630-377-6495 AVDS0060I • 12 I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION. OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0188 Page 1 of I CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.Iinhart©systemsensor.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix °K" indicating indoor or outdoor use, or may be followed by suffix 'P" for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SA..WBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8 - 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *hornlstrobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is Suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three- pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. *Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct etiv operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division r SYSTEM $ SENSOR I Audible Visible Accessories I System Sensor offers a wide range of Audible Visible (A V) accessories to enable you to meet a variety of application requirements. Features MP120K Mounting Plate Designed for both indoor and outdoor use Plug-in design eliminates ground faults Power supply that converts 120 VAC to nominal 24 V FWR Compatible with all two-wire SpectrAlert Advance® devices Color Lens Attachments Easily turns any device into a strobe for ECS, severe weather, sprinkler activation and more Outdoor rated from -35°F to 151°F Wall- or ceiling-mount lenses available UL 1638 listed WTP Weatherproof Plates Enables flush mounting of outdoor devices to brick, ceramic tile, concrete, and masonry brick Weatherproof per NEMA 3R For use in both indoor and outdoor applications For use with all K series (outdoor) products replacement -R models Universal mounting plate easily attaches to the weatherproof plate The MPI 20K Mounting Plate is designed to use 120 VAC to power SpectrAlert Advance horns, strobes, horn strobes, chimes, and chime strobes. Color Lens Attachments install easily on any indoor or outdoor SpectrAlert Advance strobe devices to provide distinctive visual signaling. WTP Series Weatherproof Plates enable installers to flush mount outdoor horns, strobes, horn strobes, speakers, and speaker strobes to a variety of wall surfaces, including brick, ceramic tile. concrete, and masonry brick. These NEMA 3R-rated plates come in red and white to suit aesthetic and functional requirements. They may be used indoors or outdoors (with outdoor devices), as required by conditions. They easily attach to the SpectrAlert Advance universal mounting plate. Trim Rings for speakers and speaker strobes allow for additional space within the backbox. Trim rings for horns, strobes, and horn strobes allow 4-wire devices to mount to a single-gang back box. SpectrAlert Advance Outdoor Back Boxes ensure a NEMA 4X watertight listing for AV devices. In locations where a SpectrAlert Advance device is surface mounted, Back Box Skirts are the best solution to mask the back box. Retrofit Plates cover paint outlines on the wall when replacing legacy SpectrAlert Advance products. SpectrAlert Advanàe DECALS are for use on our non-pad printed wall- and ceiling-mount devices. Each decal comes with AGENT, EVAC, ALERT, or FIRE label options. The Sync.Circuit Module synchronizes SpectrAlert Advance strobes at 1 Hz and horns and chimes at temporal 3 over a single pair of wires. Patented module technology also allows the silencing of horns or chimes on horn strobe and chime strobe models over a pair of wires. See Datasheet A05- 1007-005 for more information. I Agency Listings L) ( MEA I USTED C.i approved S4011 S3503 I 73-1653195 582.O8-E 73OO-1653204 I .Specifications IIaI,] 120 VAC mounting plate model MP120K shall be listed to UL 464 for fire protective signaling systems. The mounting plate shall power a I two-wire SpectrAlert® Advance horn, strobe, horn strobe, chime or chime strobe from a 120 VAC supply converted to nominal 24 V FWR. For indoor applications, the mounting plate shall be installed in a 4x4x2'/8 -inch junction box. For outdoor applications, the mounting plate shall be installed using the proper SpectrAlert Advance outdoor weatherproof back box and outdoor listed notification appliance. I MP1 20K may be used with any of the following products at all horn and strobe settings: P2R, P2RH, P2RK, P2RHK, P2W, P2WH, SR, SRH, SRK, SRHK, SW, SWH, PC2R, PC2RH, PC2RK, PC2RHK, PC2W, PC2WH, SCR, SCRH, SCRK, SCRHK, SCW, SCWH, HR, HRK, HW, SR-P, SW- P, SRH-P, SWH-P, P2R-P, P2W-P, P2RH-P, P2WH-P, SCR-P, SCW-P, SCRH-P, SCWH-P, PC2R-P, PC2W-P, PC2RH-P, PC2WH-P, SR-SP, SRH-SP, P2R-SP, P2RH-SP, SCW-SP, SCWH-SP, PC2W-SP, PC2WH-SP, CHR, CHW, CHSR, CHSW I Physical/Operating Specifications Standard Operating Temperature -40°F to 151°F (-40°C to 66°C) Humidity Range 10 to 93% non-condensing (indoor products) I Nominal Voltage Regulated 120 VAC Operating Voltage Range 96-132 VAC Current Draw From AC Line 150 mA max. I The SpectrAlert Advance weatherproof plate for horns, strobes, and horn strobes shall mount to 4x4x1 1/4-inch and 2x4x1 1/2-inch back boxes. The weatherproof plate for speakers and speaker strobes shall mount to 4x42118-inch back boxes. The weatherproof plate may be installed on brick, concrete, ceramic tile, and masonry brick and must be used with System Sensor "K" series outdoor replacement models (-R). Outdoor SpectrAlert Advance products shall operate between -40°F and 151°F. I Physical Specifications Speaker Strobe 7.25" Lx 6.26' W x 3.00" D (including speaker and lens) Speaker 7.25' Lx 6.26" W x 1.30" D (including speaker) I Horn Strobe 6.90' Lx 5.90" W x 2.80" D (including strobe lens) Horn 6.90" Lx 5.90" W x 1.60" D (including horn) Note: 'NIP and WTPW are compatible with 4x4x11/4-inch and 2x4xl1/2-inch back boxes. (Compatible with outdoor horns, horn strobes and strobes) I WTP-SP and WTP-SPW are compatible with 4x4x2 1/8-inch back boxes. (Compatible with outdoor speakers and speaker strobes) Models Available for Use with the Watertight Plates: WTPSWTPW HRK-R I WTPIWTPW . SRK-R. SRHK-R, SWK-R, SWHK-R WTPIWTPW P2RK-R, P2RHK-R, P4RK-R, P2WK-R, P2WHK-R WTP-SP SPRK-R, SPWK-R WTP-SPW SPSRK-R I Note: -R models ship without the outdoor back box. The weatherproof mounting plates are designed to be used only with -R replacement models. I I I I I AVDSOO4O1 I. Specifications The System Sensor SpectrAlert Advance color lens attachments shall be approved for fire protective service as listed in UL 1638. The lens attachments shall only be used with non-FIRE-printed System Sensor strobe devices. The lens shall mount to any wall- or ceiling-mount strobes and shall be rated from —35°F to 151°F. ITm11Ik Color lens attachments may be used with the following System Sensor plain (non-FIRE-printed) indoor or outdoor strobe models: SR-P. SRH-P, SW-P, SWH-P, P213-P, P2W-P, P2WH-P, P2RK-P, P2RHK-P, SCW-P, PC2R-P, PC2W-P, PC2WH-P, SPSW-P, SPSR-P, SPSWH-P, SPSRH-P SPSWV-P, SPSRV-P, SPSCW-P, SPSCWH-P, SPSCWV-P, SPSCVWH-P, SRK-P, SRHK-P, SWK-P, SWHK-P, P2WK-P P2WHK-P, SPSWK-P, SPSRK-P, SW-CLR-ALERT, SCW-CLR-ALERT, SPSCW-CLRALERT. Color Lens Installation Installation to Wall-Mount Strobe Installation to Ceiling-Mount Strobe Candela Rating for UL 1638 Light output of color lenses is measured per UL 1638, on axis, and is cI derated. Strobe Output (cd) Candela Switch Setting On-Axis Candela Rating (UL1638) —All Colors 15 15 15/75° NA 30 30 75 75 95 95 110 110 115 115 135 135 150 150 177 177 185 185 *15/75 Candela setting not to be used with color lenses AVDSOO4O1 Ordering Information Metal Weatherproof Backboxes MWBBW white, wall-mount, compatible with: SPWK-R, SPWK, SPSWK-R, SPSWK-P, SPSWK MWBB red, wall-mount, compatible with: SPRK-R, SPRK MWBBCW white, ceiling-mount, compatible with: SPCWK, SPSCWK,SPCWK-R, SPSCWK, SPSCWK-R, SPSCWHK, SPSCWHK-R SA-WBBW white, wall-mount, compatible with: P2WK, P2WHK, P2WHK-P, P2WK-P, SWK, SWK- P,P2WHK-R, P2WK-R, SWHK-R SA-WBB red wall-mount, compatible with: P2RK, P2RK-P, P2RK-R, SRK, SRK-P, SRK-R P2RHK, P4RK, P4RHK, SRHK, HRK, P2RHK-R, P2RK-R, HRK-R, P4RHK-R, P4RK-R, SRHK-R SA-WBBCW white, ceiling-mount compatible with: PC2WK, SCWK SA-WBBW white, wall-mount, compatible with: P2WK, P2WHK, P2WHK-P, P2WK-P, SWK, SWK- P,P2WHK-R, P2WK-R, SWHK-R Back Box Skirts BBS-2 red, wall-mount, compatible with: P2R, SR, KR, Cl-ISR, CHR, P2RH, P4R, P4RH, SRK, M-P, P2RH-P, P4R-P, P4RH-P, SR-P, SRH-P, SR-SP, SRH-SP, P2R-SP, P2RH-SP BBSC-2 red, ceiling-mount, compatible with: PC2R, SCR, PC2RH, PC4R, PC2RH-P, SCRH, PC2R-P, SCR-P, SCRH-P BBSW-2 white, wall-mount, compatible with: P2W, SW, HW, CHSw, cHw, P2WH, P4W, P4WH, SWH, SW-ALERT, SWH-ALERT, SW-CLR-ALERT, SW- P, SWH-P BBSCW-2 white, ceiling-mount, compatible with: PC2W, SCW, PC4W, PC4WI-I, SCWH, SCW-SP, SCWH- SP, PC2W-SP, PC2W1-l-SP, PC2W-P, PC2WH-P, SCWH-P, SCW-P, SCWH BBS-SP201W Surface-mount back-box skirt for the PF24V (ExitPointtM Directional Sounder with Voice Messaging) SPBBS red, wall-mount, compatible with: SPR, SPSR, SPRV,SPSR-P,SPSRH,SPSRH-P SPBBSC red, ceiling-mount, compatible with: SPCR, SPSCR SPBBSW white, wall-mount, compatible with: SPW, SPSW, SPWV, SPSW-CLR-ALERT, SPSW-ALERT, SPSWH, SPSWH-P, SPSWV SPSWV-P SPBBSCW white, ceiling-mount, compatible with: SPCW, SPSCW, SPCWV, SPSCW-CLR-ALERT, SPSCW-P, SPSCWH, SPSCWH-P, SPSCWV, SPSCVN-P, SPSCWVH, SPSCWVH-P Colored Lenses LENS-B Wall-mount, blue LENS-R Wall-mount, red LENS-G Wall-mount, green LENS-A Wall-mount, amber LENS-BC Ceiling-mount, blue LENS-RC Ceiling-mount, red LENS-GC Ceiling-mount, green LENS-AC Ceiling-mount, amber Decals DECAL-R red, used for non-pad-printed wall-mount devices. (10 total decals per box for 5 devices)* DECAL-RC red, used for non-pad-printed ceiling-mount devices. (15 total decals per box for 5 devices)" DECAL-W white, used for non-pad-printed wall-mount devices. (10 total decals per box) for 5 devices" DECAL-WC white, used for non-pad-printed ceiling-mount devices. (15 total decals per box for 5 devices)" "All Decals include Labels: "AGENT, EVAC, ALERT & FIRE" Retrofit Plates (For use with horn strobe & speaker strobe devices) RFPW 9.5'x 7" white RFP 9.5" x 7" red Mounting Plate MP120K 120 VAC Adapter Mounting Plate Sync Modules MDL3W white, 12/24 volt Sync-Circuit module. MDL3R red 12/24 volt Sync-Circuit module Trim Rings TR red, wall-mount for use with speaker devices TRC red, ceiling-mount for use with speaker devices TRC-HS red, ceiling-mount for use with horn strobe devices TRCW white, ceiling-mount for use with speaker devices TRCW-HS red, ceiling-mount for use with horn strobe devices TR-HS red, wall-mount for use with horn strobes devices TRW white, wall-mount for use with speaker devices TRW-HS white, wall-mount for use with horn strobe devices Watertight Plates WTPW white, for use with horn, strobes & horn strobe devices WTP red, for use with horn, strobes & horn strobe devices WTP-SPW white, for use with speaker devices WTP-SP red, for use with speaker devices I SYSTEM $ SENSOR I 02012 System Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Product specitications subject to charW witnout notice. visit r/stemsensoccom Phone: 800-SENSOR2 • Fax: 630-377-6495 for current product information. includin ft latest version of We data stieft AVOS0040I .3112 I . CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL r9r71 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM I .. LISTING SERVICE LISTING No. 7300-1653:0204 . Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNITACCESSORIES/MISC. DEVICES I LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave. St. Charles, IL 60174 Contact: Irish Linhart (630) 762-5025 Fax (630) 377-7245 I . Email: trish.Iinhart©systemsensor.com DESIGN: Models LENS-B, LENS-R, LENS-G, LENS-A, LENS-BC, LENS-RC, LENS-GC, and LENS-AC retrofit colored strobe lenses for non-fire applications with all System Sensor I .SpectrAlert Advance models having °-P" or "K-P" suffixes. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: LENS-B: blue rectangular lens I LENS-R: red rectangular lens LENS-G: green rectangular lens LENS-A: amber rectangular lens I LENS-BC: blue circular lens LENS-RC: red circular lens LENS-GC: green circular lens I LENS -AC: amber circular lens INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. I MARKING: Listee's name, model number, and UL label. APPROVAL: Listed as retrofit colored strobe lenses for use with listee's separately listed and compatible I strobe lights for non-fire applications. For indoor or outdoor use. Refer to listee's Installation Instruction Manual for details. NOTE: I Not approved for use as fire ..signaling devices for the hearing impaired. I 1O-17-O8bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed I the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria.'Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 I Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division