Loading...
HomeMy WebLinkAbout1289 CARLSBAD VILLAGE DR; ; FA100030; Permit11/3/2020 FAI 00030 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FAI 00030 1.289 CARLSBAD Job Address: . Status: ISSUED VILLAGE DR Permit Type: FALARM . . Applied 6/8/2010 Parcel No: 1561907006 . . Approved: 6/8/2010 Lot #: 0 Reference No.: . Issued: 6/8/2010 PC #: Inspector: Project Title: CARLSBAD ORAL. SURGERY T.I. FIRA ALRM PLAN CHECK & INSPECTIONS . Applicant' JJJ ENTERPRISES 5335 VINEWOOD ST ESCONDIDOCA 760-747-3050- ---------- Owner: TRACY DAVID J 1207 CARLSBAD VILLAGE DR #A CARLSBAD CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 125. 0 125. 0 1/1 clop 1~1 Ll FIRE ALARM • - SECURITY • LOW VOLTAGE SYSTEMS • J • • • • • •. CARLSBAD ORAL SURGERY 1289. CARLSBAD VILLAGE DRIVE CARLSBAD, CA 92008 • SPRINKLER MONITORING SYSTEM 3'ocQ ®Underwriters Laboratories Inc® Northbrook. IL San Jose. CA Melville, NY Applicant ID No: 892912-001 Service Center No I Expires: 31-MAR-2011 A not-for.profit organization dedicated to public safety and committed to quality service CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters Laboratories Inc. (UL) in Its Product Directories as eligible to use the UL Listing Mark In connection with Certificated Alarm Systems. The only evidence of compliance with ULs requirements is the Issuance of a UL Certificate for the Alarm System and the Certificate Is current under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. Listed Service From: HUNTINGTON BEACH, CA (HUNTINGTON BEACH) Alarm Service Company: (892912-001) Service Center: (892912.001) GENERAL MONITORING SERVICES INC GENERAL MONITORING SERVICES INC 17951 LYONS CIR 17951 LYONS CIR HUNTINGTON BEACH CA 92647 HUNTINGTON BEACH CA 92647 The Alarm Service Company Is Listed In the following Certificate Service Categories: File - Vol No. CCN Listina Cateaory $7894-I UUFX [Signal and Fire Alarm Equipment and Services) (Protective Signaling Services) Central Station ***THIS CERTIFICATE EXPIRES ON 31-MAR-2011 "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" (D 2008 UL Form CS-CC 22-FEB-2010 CARLSBAD ORAL SURGERY 1289 CARLSBAD VILLAGE DR. CARLSBAD, CA 92008 BILL OF MATERIALS DMP XR5FC FIRE ALARM CONTROL PANEL CSFM# 7165-1157.104 DMP 692F REMOTE FIRE COMMAND KEYPAD CSFM# 7165-1157:104 DMP 521 BIBXT SMOKE DETECTOR CSFM# 7272-0028:106 DMP 850S PULL STATION CSFM# 7165-1157:104 SYSTEM SENSOR P2R TWO WIRE H/S WALL MOUNTED RED CSFM# 7125-1653:138 PIBV2 SUPERVISORY SWITCH CSFM# 7770-1653:118 performance for smë.l commerciat applications b----_ SIGNAUNG LISTED NYC MEA Economical, refliafe XR5 commercial fire and slave communicators from DMP are perfect for small commercial installations that require reliable, cost-effective monitoring. Built-in 2-Line dialer 500mA auxiliary power One Class A (Style D) zone for sprinkler supervision Four Class B (Style A) smoke-detector zones Four Class B (Style A) expansion zones Rely on DMP to increase the value of your next fire alarm installation. High-quality DMP panels and network monitoring technologies have led the industry for decades and significantly reduce the cost of monitoring communications. XR5 —9 ZONE COMMER.C1AL FIRE PANEL - - SYSTEM FEATURES One Class A (Style D) waterfiow zone DMP Serial 1 or Contact ID communication formats Four Class B (Style A) 2-wire smoke detector zones Compatible with the iCOMsi for network/ Internet reporting Four Class B (Style A) expansion zones using 714 or 715 . Programmable reporting to one or two central stations lOOmA 12 VDC switched 4-wire smoke power (XR5FC) Remote upload/download with Remote Link Two Form C relay outputs optional Built-in plain English programming from any keypad Four open collector outputs for annunciation Individual zone programming for fire, fire verification, Built-in dual phone line module with line monitoring retard delay, cross-zoning, and fire supervisory Built-in bell circuit trouble monitor, connects to Model 865 Compatible with 630F and 692F keypads or 866 Notification Circuit Modules Fire Drill feature for practice evacuations 600mA alarm bell output (XR5FC) Swinger bypass option on all zones 500mA auxiliary output Inherent power limited circuits Operates on 16 VAC power Automatic recall test reporting 4-wire keypad and annunciator circuit One-man Walk Test 16 event history can be viewed from 630F keypad Automatic standby battery test - -- * t - - cL I j:- :'( T1_. j!']L.L .ifi[.I.r •JF ..fTLH. FIRE COMMAND KEYPADS 630F Remote Fire Command 32-character LCD 635-R Keypad Conduit Backbox 692F Fire Command Keypad AUXILIARY MODULES 377 Trouble Annunciator Module (included with XR5SL) 860 Relay Module 865 Style WIX Notification Circuit Module 866 Style W Notification Circuit Module iCOMSL Network Alarm Communicator EXPANSION MODULES 714 4-zone Class-B Expansion 715 4-zone 2-wire smoke Expansion POWER SUPPLIES 504-24 Provides 4 Amps @ 24 VDC 504-24LX Provides 4 Amps @ 24 VDC 505-12 Provides 5 Amps® 12 VDC 505-12L Provides 5 Amps @ 12 VDC 505-12LX Provides 5 Amps @ 12 VDC COMPUTER SOFTWARE Remote Link Upload/Download Programming Software System Link End-User Management Software Advanced Reporting Module Alarm Monitoring Module Command Center Module Link Server Application DETECTORS SLR-835B Photoelectric Smoke 521 B/BXT Addressable Smoke, CleanMe1M ACCESSORIES 300 Plug-in Harness 305 Plug-in Relay Output 306 Harness Connection 318 Dual Battery Harness 320 40 VA Wire-in Transformer 367 12 VDC 7.7Ah battery 370RJ Lightning Suppressor with Two Ri Jacks SPECIFICATIONS LISTINGS AND APPROVALS Primary Power 16.5 VAC 40VA transformer (Model .320) Refer to the XR5 Installation Guide (LT-0229), XR5 Programming Guide Secondary Power 12 VDC 7.7Ah battery (Model 367) (LT-0312) and specific compliance listings for installation and Outputs programming requirements necessary to meet a particular Auxiliary 500mA@ 12 VDC approval. Annunciator 50mA each (switched ground) California State Fire Marshal (CS FM) XR5FC Outputs FCC Part 15 Alarm 600mA@ 12 VDC FCC Part 68 Smoke lOOmA @ 12 VDC New York City (MEA) Enclosure Red (Models 340FC or 3405L) Underwriters Laboratories (UL) Listed Dimensions 12.5" x 9.5" x 3.75" ANSI/UL 864 Control Units for Fire-Protective Signaling Systems Material 20-gauge cold-rolled steel For additional information, access www. . dmp.com and select Compliance. I.I*1Ifl:P INTRUSION - FIRE - ACCESS - NETWORKS 500 North Partnership Boulevard Olgitni Monitoring Products Springfield, Missouri 65803-8877 ,-. ..:• - COMMUNICATION Each XR5 panel contains a built-in dual phone Line module with line supervision that can communicate to one or two remote receivers using DMP Serial 1 digital dialer or Contact ID (CID) formats. You can also selectively enable alarm, supervisory/trouble, backup, and recall test reporting to either of the two receivers. NETWORK MONITORINGTm An iCOMsL Network Alarm Communicator connects to the XR5 to provide Internet/ LAN/WAN communications to the panel. When used in this manner or as a slave or stand-alone network communicator, the iCOMsi. reduces or eliminates costly telephone lines and communicates to the central station via high-speed network connections. ONE-MAN WALK TEST Conduct one-man tests of the system and all connected devices using the Walk Test feature. Simply enter an access code into the keypad and XR5 panels automatically enter test mode. Each time a zone trips during the test, the bell rings for two seconds and a Sensor Reset is automatically performed to reset latched detectors. When the test is completed, the results display at the keypad and can be sent to the central station. 714 ZONE EXPANDER The 714 provides four inputs and is suitable for use with normally open and normally closed fire devices. 714 inputs are supervised and can be programmed for any zone type. The 714 connects to the keypad bus. 715 ZONE EXPANDER The 715 expander provides four Class B powered inputs and is suitable for use with the 2-wire conventional smoke detectors. 715 inputs are supervised and can be programmed for any zone type. The 715 connects to the keypad bus. POWERFUL FALSE ALARM REDUCTION FEATURES The built-in false alarm reduction features include cross zoning, fire verification, fire retard, and CLeanMeiM reporting. Cross zoning allows multiple zones to be cross zoned and reports alarms only when two or more zones fault within a programmable time of 4 to 250 seconds. Should just one zone trip, only a zone fault report is sent to the central station. Fire verification provides a 120-second window during which a smoke detector can trip, be automatically reset, and then must trip a second time before an alarm is indicated. A single trip on the zone sends only a zone fault report to the central station. Fire retard allows a programmable time of up to 250 seconds for waterflow detection. This eliminates the need for additional mechanical delays at the tlowswitch. ANNUNCIATOR OUTPUTS Four open collector outputs can be used for a variety of remote control and annunciation applications. Each output is rated for 50mA maximum. Add the Model 860 Relay Output module to provide four form C relay contacts. Each Model 305 relay is rated at 42mA and the module easily mounts inside the XR5 enclosure. TROUBLE ANNUNCIATOR MODULE For slave communicator applications, the XR5SL provides an enclosure door- mounted Model 377 Trouble Annunciator Module. The Model 377 offers Trouble and System OK LEDs with audible alert and a Silence button for acknowledging trouble conditions. BUILT-IN PROGRAMMER An internal English text Programmer enables technicians to easily program and test the panel from any keypad. A Lockout code restricts access to only authorized persons. REMOTE PROGRAMMING Remotely program XR5 panels using Remote Link programming software from DMP. You can upload panel programming, make the necessary programming changes, and then download the revised programming into the panel. Expand Remote Link/System Link functionality with Advanced Reporting, Alarm Monitoring, Command Center, or Link Server packages. 630F FIRE COMMAND CENTER KEYPAD OPERATION For system annunciation, include the DMP 630F Fire Command keypad in your installation. This 20-key, 32-character LCD annunciator provides full-text displays of system events and menu prompts. It can be used for system operation, annunciation, and programming. The 630F is protected by either a keyswitch or code. The keyswitch enables the four function buttons: Silence, Reset, Test, and Fire Drill. Install the 630F using the included backbox and trim frame for flush-mount applications and the 635-R backbox for surface mount applications. The 630F has the ability to annunciate all on-board and expansion zones on the XR5. 692F FIRE COMMAND LED KEYPAD The 692F Fire Command LED Keypad offers 5 sets of highly visible LED annunciation of alarm and trouble conditions. It provides individual zone alarm and trouble LEDs for zones one to five only. Also, system LEDs, an internal sounder, 2-button Fire alarm initiation, and only Silence, Reset, and Fire Drill functions are provided. The 692F is used in applications where only the panels five on-board zones are used. ®LII]LI]® Telephone Direct avower to unswochod 120 VAC 60 Hz Yodel 320 I wiro.In Inhistelme, 16.5 VAC 4OVA Secondary Pourer Supply i~af I2VDC 1.2 Amps Max. thurakig monet. Cold Water Pipe GROUND Earth Ground tly to 500M awr01a1y current at I2VDC Ira,, terminal Keypad Model 630F 63mA at 8.5 10 14 VOC 19 a • I - ED CD a ED Model 377 Trouble Sitence/Rneet Panel Annunciator Module Silence/Reset 00 Silence/Reset 0 Bell II Monitor Relay Sodrats for Optional Form C Outputs on 315 ZlA+ZM-B+Z1 Z2+ Z2- 20+ Z4+ Z 20+ Z I rtr' Output Header J12 WII 3.31€ Ohm Few Open Collector Outputs. 2 Zo,105 Resistor SernA at 30 VDC resistive output I Oulpul 2 Model 309 (Joe 11050€ 300 Harness ZoO I Output Header All M p p TwoFormC(SPO1)Oatpuls. Zexlo2 Zeee3 Zone 3.31101,m 1311 Ohm 3.3k 0h. Supervised CircuS - Keypad Model 692F - 30mAal8lo16VDC. cm c m mm 5 Zone LED Keypads XR5FC System Configuration Diagram cc Digital Monitoring Products CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -:BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE CA 7-7 LISTING No. 7165-1157:104 Page 1 of 1 CATEGORY: Fire Alarm Control Unit (Commercial) LISTEE: Digital Monitoring Products, 2500 N. Partnership Blvd., Springfield, MO Contact: Terry Shelton (417) 831-9362 Fax (417) 831-1325 fshelton@dmp.com DESIGN: Model XR5FC and XR5SL fire alarm control units. Automatic, manual, noncoded, local, remote station, central station, waterfiow and sprinkler supervisory service. Model XR5SL does not employ a bell output circuit or 4-wire detector power, it is used for slave applications deriving its power from the host (master) control unit. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: XR5FC, XR5SL Control Panels 630F*, 692F . Keypad 865,866 Bell Module 320 . Power Transformer 377 . . Trouble Indicator Module *714*715 . Zone Expanders INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed electrically and functionally. compatible initiating and indicating devices. The control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to listee's Installation Instructions Manual for details. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: For Alarm Verification Feature, the maximum Retard/Reset/Restart (including smokedetectOr reset time) shall not exceed 30 seconds. *Rev. 02-19-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test rsults and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or ;'• recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. . I Date Issued: JUNE 24, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division LISTED DMP Fire Command Keypads provide a variety of fire annunciation solutions for residential and conriemal fire applications. Using the 692F Fire Command Keypad, alarm and trouble conditions on XR5FC and XR5SL Commercial Fire Panetsdisptayon the hiy v(e LED annunciator. Simple one-button operation to silence alarms, reset sensors, test the system, and perform a fire drill make the 630F easy to Operate. The 630F, 690F, and 790F Fire Command keypads from DMP 32-character full text LCD readoutdqlays system events and rreru prompts that make the keypads efficient and easy-toe. 692F9 63 OF, 59OF, AND YVOF FIRE COMMAND CENTER FEATURES 630F FEATURES Simple hamess connection to4-wirekeypad bus 32-character LCD display At-a-glance system status Flush or Surface mount Powered from panel or auxiliary power supply Keyswitch enables single button operation Optional backboxes for conduit or wall mount applications Full operation with authorized code Attractive non-obtrusive designs Built-in diagnostics 2-button Panic keys AC Power, Trouble, Alarm LED . Compatible with XR2400F, X11200, orXR200-485 92F FEATURES Three status LEDs: Silenced, Trouble, and Power . System events in plain English 10 zone LEDs: 5 Trouble LEDs and 5 Alarm LEDs 690F1790F FEATURES No addressing required - use as many as you need e 32-character LCD display Zone monitoring feature for all zones Compatible with all DMP panels Four short tones indicate an unsuccessful keypad operation 790F keypads provide four Class B zones Audible tone on each key press Displays system events/user activity Quick key on keypad for changing user code o AC power LED 2 ZOotLEt1rpI, ¶ouble Bypassed and Alarm cochttons .. RETROFIT EXISTING DMP SYSTEMS Designed to allow easy retrofitting, the Fire Command" keypads are compatible with all tviPpanels. DYIP recommends using the 692F with the XR5 panel. Adding a keypad does not require new wiring, special modules, or panel upgrades. You can provide anew look and greater functionality to an existing system at just a fraction of the cost for all new equipment. 2-BUTTON PANIC KEYS The Fire Command Keypads allow the top row of keys to be used as 2-button Panic keys. This feature lets the user press and hold two of the keys simultaneously to send a Panic, non-medical Emergency (options not available on 692F), or Fire Alarm report to the central station. An adhesive label is provided with the keypads to identify the Panic keys to the user. KEYBOARD BACKLIGHTING The Fire Command keypads also illuminate the keyboard in green whenever a key is pressed or the internal buzzer sounds. This allows users to enter their code or perform a command function in very low light conditions. This option is not available on the 630F Keypad. RED ALARM BACKLIGHTING The keypads offer one of the most unique features found on any keypad. During an alarm condition on the system, the keyboard backlighting turns a bright red. This change in color from the normal green backlighting helps people on-site to instantly recognize an alarm condition. This option is not available on the 630F Keypad. BUILT-IN DIAGNOSTICS An internal diagnostics program lets installers and service technicians test the operation of the keypad at any time without disabling the system. The diagnostics program tests the keypad's prewarn tone, LCD segments and backlighting, each of the keyboard's 16 keys, and the 790F keypad's four protection zones. This option is not available on the 692F Keypad. SUPERVISED AND UNSUPERVISED OPERATION You can program the keypads for supervised or unsupervised operation on the keypad data bus. When supervised, the keypad occupies its own address. Unsupervised operation allows you to install multiple keypads on the bus with the same address. This feature greatly increases the overall number of keypads you can install to provide maximum flexibility in operating the system. The 692F is always unsupervised. 692F FIRE COMMAND KEYPAD The 692F Fire Command Keypad offers highly visible LED annunciation of alarm and trouble conditions on DMP XR5FC and XR5SL Commercial Fire Panels. The 692F provides individual zone alarm and trouble LEDs, status LEDs, an internal buzzer, 2-button functions. The 692F also includes an easy-to-read backlit keyboard with large alphanumeric characters. The 692F is cased in a stylishly designed, durable red plastic housing with removable base for easy installation. STATUS LEDS The green Power LED lights when primaryAC or DC power to the panel is at an acceptable level and flashes when its battery is low or missing. Ayellow Trouble LED turns on when either the panel has failed to communicate with the central station receiver or when phone line 1 or 2 is in a bad condition. The 692F also uses a yellow Silenced LED to indcatewhen the paneI Bel[ Output has been silenced. ZONE LEDS Ten zone LEDs indicate the status of the zones. Each zone has a trouble and alarm LED to indicate at-a-glance zone status. KEYPAD FUNCTION KEYS There are four clearly labeled function keys on the 692F keypad. The SILENCE, RESET, TEST, and CODE function keys allow the user to press one key to initiate operations. As an added security measure, the user must enter a valid security code after pressing one of the function keys. . -•'-- ';:-4 ;• I 630F REMOTE ANNUNCIATOR The 630F Fire Command Center from DMP offers high quality, cost effective fire system control with an easy-to-use keyboard interface. The 32-character full text LCD readout displays system events and menu prompts making the 63CF keyboard efficient and easy-to-use. SINGLE-BUTTON OPERATION The 63CF Fire Command Center Keyboard has a factory installed keyswitch that enables the four function buttons—Alarm Silence, System Reset, System Test, and Fire Drill. The user can also access these functions through the User Menu by entering a valid user code at the Keyboard. USER MENU Users can access all of the functions necessary to operate and maintain their system right from the keyboard User Menu. These function include Alarm Silence, Reset Sensors, and Display Evants. MOUNTING The 630F comes with its own backbox and trim frame, providing an attractive installation. The keypad can either be flush- mounted orsurface-mounted. 690F1790F FIRE COMMAND KEYPADS Both 690F and 790F Fire Command keypads provide a 32-character LCD display, a large backlit alphanumeric keyboard, and an internal multi-tone speaker Userscan perform all system functions mmtheypadsinduthngarrmng, disarming, bypassing zones, and silencing alarms as welt as choosing any of the User Menu options. The 790F Security Command Keypad also provides four Class B protection zones for use in a variety of fire applications. FOUR PROTECTION ZONES To save the expense and potential service problems inherent in "home-running" your security devices to the panel, the 790F Fire Command Keypad provides four fully programmable Class B protection zones you can use for a variety of burglary and fire applications. Multiple Fire Command keypads can also be installed on the same wire run to increase the cost savings of each installation. USER SELECTABLE OPTIONS Each keypad provides a simple User Options menu through which users can change the display and speaker characteristics of the keypad. Simply holding the COMMAND and Back Arrow keys down for two seconds causes the keypad to display SET BRIGHTNESS. Once in the menu, the user can adjust the several options to customize the keypad for personal. preferences. DISTINCT SOUND PATTERNS The 690F and 79OF Fire Command Keypads also provide distinct sound pattemsorburLary alerts, fire alerts, door monitors, and prewam that can help users identify an event occurring on their system. USER MENU Users can access all of the functions necessary to operate and maintain their system right from the keyboard UserMenu. These function include Alarm Silence, Reset Sensors, and Display Events. The User Menu is restricted so that a valid usercode is required before access is granted to any of the functions. This protection allows you to install the keyboard in even high traffic public areas without danger of unauthorized access. KEYPAD REFERENCE CHART Keypad Zones Display Panic Compatible Keyboard User Operating Operating Type Keys Panels Red in Alarm Brightness Voltage Current 630F Fire Command None LCD Yes XR200, XR2400F, and xR200-485 No Yes 12 VDC lOOmA; lOOmA 690F Fire Command None LCD Yes All Yes Yes 12 VDC lOOmA; lOOmA 692F Fire Command None LED Yes XR5FC/SL No Yes 12 VDC 30mA; 7OmA lOOmA + 1.6mA 790F Fire Command Four LCD Yes All Yes Yes 12 VDC per acbve zone; lOOmA + 2mA per zone in alarm 692F SPECIFICATIONS Operating Voltage 8.5 to 15 VDC Current Draw 30rrt4gandby, 7GMmaxinwi Dimensions 6.8"Wx5.0"I1x1.1"D Panel Compatibility XR5FC and XR5SL 630F SPECIFICATIONS Operating Voltage 8.5 to I5VDC Current Draw lOOrM Trim Frame Dimensions 10.4"W0.0"H0.7"D BackboxDimensions 8.75"Wx6375"Hx2.5"D Panel Compatibility XR200, XR2400F and XR200-485 690F1790F SPECIFICATIONS Operating Voltage 8.0 to 16 VDC. 690F Current Draw WrAstandbyandalarm 790F Current Draw Stan* ICOmA + 1.6m4perz0ne Alarm: lOOmA +2mAperactivezone Dimensions 6.8"Wx5.0"Hx1.1"D Panel Compatibility All DMP Command Iocessor PdnelS KEYPAD ACCESSORIES 695 1.5" Keypad Conduit Backbox 696 1/2 Keypad Backbox 699 Keypad Deskstand WR-0004 4-wire Replacement Harness WR0012 12-wire Replacement Harness WR-0512 5-foot 12-wire Replacement Harness LCD Keypad Housing LED Keypad Housing Note: Backboxes not compatible with 630E APPROVALS UL 864 Control Units for Fire Protective Signaling UL 985 Household Fire UL294Access Control UL 985 Household Fire Warning UL 1076 Proprietary Burglar ULlo23 Household Burglar UL 1610 Central Station CSFM 2500 North Partnership Boulevard Springfield, Missouri 65803-8877 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1157:124 Page 1 of 2 CATEGORY: LISTEE: DESIGN: Control Unit (Non High-Rise) Digital Monitoring Products, 2500 N. Partnership Blvd., Springfield MO 65803 Contact: Terry Shelton (417) 831-9362 Fax (417) 831-1325 tsheItondmp.com Model XR2500F combination fire and burglary alarm control unit. Local, remote station, proprietary, and centralstation services. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: XR500 322, *323, *327 725 716 717 630, *630F 690, 693, 790 791, 790F, 793 7060, 7060A, 7160, 7063, 7063A, 7163, 7070, 7070A 7170, 7073, 7073A, 7173 866 893A 71 OF 481, 462N, 462P *461 714, 714-8, 714-16, 715, 711 715-8, 715-16, 725 860 865, 867, 869 893A 733,734 303 710 Iloox 1101, 1102,1103 Main Board Transformer Adaptor Zone Expander Output Expander Annunciator Module Supervised LCD Keypad Supervised LCD Keypad *LCD Keypads *LCD Keypads *LCD Keypads Indicating Module Dual Phone Line Module Bus Splitter *Interface Card Interface Adaptor *Zone Expanders *Zone Expanders *Relay Module *Indicating Module *Dual Phone Line Module *wlegand Interface *Resel/Silence Switch *Bus Splitter *RF (Wireless) Receiver *Wreless Transmitters RATING 16 VAC 56VA INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. Listing No. 7165-1157:124 Page 2 of 2 APPROVAL: Listed as a fire alarm control unit for use with separately listed electrically and functionally compatible initiating and indicating devices. Intended for use with separately listed Models 521LX and 52ILXT (CSFM Listing No. 7272-1157:106) 2-wire photoelectric type smoke detectors or Model SLRLX (CSFM Listing No. 7300-1157:122)2-wire smoke detector base. Refer to listee's Installation Instruction Manual for details. This control unit does not generate a temporal pattern signal. if the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation signal (for total evacuation) in accordance with NFPA 72, 2002 Edition is required the control unit must be used with appliances that can generate the temporal pattern signal. This control unit meets the requirements of UL-864, 8' Edition Standard. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Rev. 04-24-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 24, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division ?=EL PRODUCT INFORMATION BULLETIN CleanMe® remote maintenance reporting reduces false alarms Smart dual fixed/rate of rise heat works with photo chamber to catch fires faster Built-in drift compensation reduces false alarms Field replaceable optical chamber makes servicing a snap Small, low profile design blends in with any environment ((IeanMe' COMPATIBLE 521 SERIES Low Profile, Self-Diagnostic, Two. Wire, Photoelectric Smoke Detector with CleanMe® UL Model numbers: 521B, 521 BXT, 52ICRXT ULC Model numbers: 52813, 528BXT (U- -; ~ g California State Fire Marshal Approved LISTED The ESL 521 Series self-diagnostic, two-wire smoke detectors are the industry's first conventional direct-wire smoke detectors with analog features such as remote maintenance/trouble reporting (CleanMe®), drift compensation, and multi-criteria detection. The 521 Series continually monitor their own sensi- tivity and operational status, and provide a visual and remote trouble condition if they drift out of the sensitiv- ity range or fail internal diagnostics. This meets NFPA 72 field sensitivity testing requirements without the need for external meters. The 521 has a unique feature enabling it to send a signal (CleanMe) to the ESL 505 module (sold separately) when it has drifted outside of its UL Listed sensitivity range or has failed its internal diagnostics test. The 505 is an interface module that will signal a 24V panel via relays when the 521 is dirty. Several 12V and 24V control panels have the CleanMe software built in, eliminating the need for the 505 module. When CleanMe is not desired, simply leave the switch on the 521 off and it will work as a normal two wire detector. CleanMe allows the installer time to schedule a service call and avoid a false alarm. Time between cleaning detectors is dramatically increased because of the 521's built-in drift compensa- tion. This feature, usually only available in analog systems, allows the detector to automatically adjust its sensitivity over time as it becomes dirty, increasing the life of the detector. And when the 521 has told you that cleaning is necessary, it's literally a snap with ESL's patented field replaceable optical chamber. continued 521 Series ESL Photoelectric Smoke Detectors The multi-criteria model 521 BXT/CRXT photoelectric smoke detector/fixed rate of rise heat detector includes fast response algorithms for a quick response to both flaming and smoldering fires. Fast response algorithms allow the heat detectors to work intelligently together with the photo- electric smoke detector. As soon as the heat sensor detects a rapid rise in temperature, the sensitivity of the photoelec- tric sensor increases allowing it to detect smaller particles of combustion faster. Architectural and Engineering Specifications The ESL 521 Series photoelectric smoke detector is a low- profile, self-diagnostic , two-wire detector that monitors its own sensitivity and operational status. This detector meets NFPA 72 field sensitivity requirements without the need for external meters. Built-in drift compensation automatically adjusts the sensitivity as the detector gets dirty. Normal sensing occurs every 9 seconds. This rate doubles when a signal exceeding the alarm threshold value is sensed. Two additional successive signals above the threshold level will initiate an alarm. See installation instructions for information about correct installation and maintenance. The proprietary optical sensing chamber is field replaceable, allowing quick and easy cleaning and maintenance. Dimensions: 2"(5cm)1 (12CL) Specifications: Product Data Voltage: Dip switch 1 "on ..................... 6.5-33VDC, polarity sensitive Dip switch 1 "off ................... 8.5- 33VDC, polarity sensitive Maximum ripple (pk to pk) .....................................10% (V ) Typical average standby current (24V) ..........................7f5,A Typical alarm current (24V) ..........................up to 60mA max (if not limited by control panel) Alarm Contacts ............................500mA@36VDC (resistive) Aux. Relay contacts ........................................... IA@ 30VDC Sensitivity (photoelectric) ........................3.1% + 0.50-1.00% Operating temperature ................32°F to 100°F (0° to 37°C). Operating humidity range .............0 to 95% Non-condensing I RFI Immunity ...........................20V/m minimum; 0-1000MHz' Field wiring size ...................................................12-24 AWG Heat detector specifications: Rate of rise .... 150F/mm and >105°F (8.30C/mm, > 40.6°C) Fixed ...............................................................135°F (57°C) UL two-wire compatibility identifier: Dip switch 1 "on " .......................................................... SO9A Dip switch l "off ............................................... S1 OA, S11A Drift compensation adjustment...........................1.0%/ft. max Reset time.................................................I second minimum Detector head dimensions: Diameter ...............................................................5" (12cm) Height.....................................................................2" (5cm) Mounting dimensions: Diameter ......................................................4.75" (12.5cm) Height..............................................................0.3" (0.8cm) Color ...................................................White head and base Detector packaging............................10 detectors per carton Listings .......................................................... UL, ULC, CSFM Model No. Description 521 B 2-wire, photoelectric, 6-24VDC with CleanMee, UL listed 521B-1OPK 10 pack of 521B (not individually boxed) 521 BXT 2-wire, photoelectric, 6-24VDC with CleanMe, multi-criteria algorithms, fixed/rate of rise smart dual heat, UL listed 521BXT-10PK 10 pack of 521BXT (not individually boxed) 521 CRXT 2-wire, photoelectric, 12-24VDC with CleanMe, auxiliary relay, multi-criteria algorithms, fixed/rate of rise smart dual heat, UL listed 528B 2-wire, photoelectric, 6-24VDC, ULC listed 528BXT 2-wire, photoelectric, 6-24VDC with CleanMe, multi-criteria algorithms, fixed/rate of rise smart dual heat, ULC listed Accessories 505 Module that interprets the 521's CleanMe signal for the panel and can convert 2-wire 521 Series to 4-wire inputs on panel 401 Test magnet in plastic shell for pole mounting SM-200 Smoke! in a Cane (canned smoke) for functional testing of smoke detectors 211 Replacement optical chambers (set of 10) PH 503.692.4052 interlog• USA &Canada: 800.541.2556 Technical Service: 800.648.1424 Faigacic: 800.483.2495 www.sernzol.com www.intertogixsecurity.com E-4224 Rev B-1 101 02001 h0e,k,gi,.Ir keedagic. Cedd,. (IL In lad SceT,alav Old. ,wtse4 Irledagiale. I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE :0FC'0RJE= LISTING No. 7272-1657:277 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: GE Security Inc. 8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 FAX (941) 308-8123 Rhonda.micocherocpe.com DESIGN: Models 521B, 511C*, 511 AFT*. 521BXT, 52ICRXT (2-wire) and 541C, 541CXT, 54IAXT (4-wire) photoelectric type smoke detectors. Model 521BXT, 521CRXT, 541CXT, 511 AFT*, and 541AXT smoke detectors employ a supplemental heat sensor to assist the smoke detector in fire situation. This heat sensor is not a heat detector and is not intended for use in lieu of the required heat detectors. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: 6.5-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric type smoke detectors for use with separately listed electrically compatible fire alarm control units. FORMERLY: 7300-0447:140 Rev. 06-05-2000 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or - .,' recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other suitable information sources. Date Issued: OCTOBER 19, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO Program Coordinator Fire Engineering Division LISTED Simple operation provides instant alarm The 850 Series Fire Alarm Pull stations offer quick and simple operation thats economical and reliable. Available in single or dual-action manual pulls SPST contacts and terminal strip connections a Gold-plated contacts to avoid the risk of corrosion MRS ALARMLL $VA 850S M 850D_____ FEATURES Approvals: UL and CSFM a Mounts on standard single-gang box Americans with Disabilities Act (ADA) compliant • Optional surface and weatherproof backboxes available Die-cast metal construction • High-gloss red enamel finish Reset key • Scored acrylic breakrod - .• ,-. S VE Wt 3Q 2-: 3A 2 DESCRIPTION MOUNTING OPTIONS 850D OPERATION The DMP 850 Series Fire Alarm Pull A variety of mounting options are On the Model 850D Dual Action Pull Station is a high quality, die-cast available for the 850 series. It can be Station, the push bar rotates inward metal manual pull station available flush mounted to a standard single gang allowing the PULL handle to be grasped in either single-action or dual-action switch box or surface mounted in two in a one handed motion. configurations with SPST contacts and optional configurations. The Model terminal strip connections. The normally 850-SB Interior Surface Backbox or the ADDRESSABLE ZONE open contact, which closes when the putt Model 850-WP Weatherproof Backbox To create an addressable reporting zone station is activated, is rated for 1 Amp® both allow conduit connection to the for the 850 Series, install a Model 71:1 30 VDC. The contacts are gold-plated to 850 Series Pull Stations. Zone Expansion module. avoid corrosion risks. Scored acrylic breakrods are used with the 850 series. COMPLIANCE The 850 series has been tested by UL for compliance to the latest requirements of the ADA. 850S OPERATION The Model 850S Single Action Pull Station is operated by pulling the handle on the front of the station as far down as it goes. When the handle locks into place it is easily visible from up to 50 feet. Reset the handle by opening the station with the supplied key, placing the handle in the normal upright position and re-locking the station. PULL Screw Terminals To next To Fire Alarm EOL resistor device or Control Panel Model 850 Wiring Diagram ORDERING INFORMATION 8505 Single-action pull station 850D Dual-action pull station 850-SB Interior surface sheetmetal backbox 850-WP Weatherproof surface die-cast backbox 850-AR Scored acrylic breakrods.(1 dozen) 850S/711 Single-action pull station w/addressable module 850D/711 Dual-action pull station w/addressable module Note: All models are supplied with one scored acrylic breakrod and one key. 2500 North Partnership Boulevard Springfield, Missouri 65803-8877 SPECIFICATIONS Switch Rating 1 Amp @ 30 VDC Dimensions 4.75" H x 3.25" W x 2.25" D Color Red w/raised white letters, white PULL handle w/raised red letters COMPATIBILITY The 850 Series Fire Pull Station is compatible with all DMP Command Processors. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1157:104 Page 1 of 1 CATEGORY: Fire Alarm Control Unit (Commercial) LISTEE: Digital Monitoring Products, 2500 N. Partnership Blvd., Springfield, MO Contact: Terry Shelton (417) 831-9362 Fax (417) 831-1325 tshelton@dmp.com DESIGN: Model.XR5FC and XR5SL fire alarm control units. Automatic, manual, noncoded, local, remote station, central station, waterflow and sprinkler supervisory service. Model XR5SL does not employ a bell output circuit or 4-wire detector power, it is used for slave applications deriving its power from the host (master) control unit. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: XR5FC, XR5SL Control Panels 630F*, 692F Keypad 865,866 Bell Module 320 Power Transformer 377 Trouble Indicator Module *714*715 Zone Expanders INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed electrically and functionally compatible initiating and indicating devices. The control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm• Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to listee's Installation Instructions Manual for details. This control unit meets the requirements of UL Standard 864, *gth Edition. NOTE: For Alarm Verification Feature, the maximum Retard/Reset/Restart (including smoke detector reset time) shall not exceed 30 seconds. *Rev. 02-19-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the testreults and/or other data but does not make an independent verification of any claims. This listing, is not an endorsement or ''' recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 24, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division —" SYSTEM $ SENSOR Selectable-Output Horns, Strobes, and Horn Strobes SpectrAlert Advance selectable-output horns, strobes, and horn strobes are rich with features guaranteed to cut installation times and maximize profits. SPECTRAlert Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12-or 24-volt operation at 15 and 15/75 candela Field-selectable candela settings on wall and ceiling units: 15,15/75, 30,75, 95, 1 IQ 115, 135, 15Q 177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for wall and ceiling units Mounting plate shorting spring checks wiring continuity before device installation Electrically compatible with existing SpectrAlert products Compatible with MDL sync module Agency Listings SIGNAUNG <S> USTED S4Ol I .I'ob,.. lIAR) ¶5512 (1I,obe,) APPROVED MI5?2 approved MEA52.05. ch,n,e flrthe) 7135-IVS3155 ,hInI.) The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, which make installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. Furthermore, a universal mounting plate with an onboard shorting spring tests wiring continuity before the device is installed, protecting devices from damage. In addition, field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. SpectrAlert Advance Specifications . I General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 X4 x 1½-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount 10 a single-gang 2 x 4 x 1'/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Syric.Circui( Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 175 volts; 24-volt-rated notification appliance Circuit outputs shall operate between 17 and 33 volts, Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75,95,110,115,135,150,177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobes entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4Il/6 x 4/6 x 21/a-inch back box.The module shall also control two Style V (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control The module shall not operate on a coded power supply. Standard Operating Temperature 32F to 120"F (0"C to 49CC) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Range2 8 to 17.5 V 02 V nominal) or 16 to 33V (24 V nominal) Input Terminal Wire Gauge 12to18AWG Ceiling-Mount Dimensions (including lens) ' 6.8diameter x 2.5 high (173 mm diameter x 64mm high) Wall-Mount Dimensions (including lens) 5.6L x 4.7W x 2.5 D (142 mm Lx 119 mm W x 64mm D) Horn Dimensions 5.6Lx4.7Wx1.3D(142 mm Lx 119mrnWx 33 mm D) Wall-Mount Back Box Skirt Dimensions (BBS-2, BBSW-2) 5.9"L x 5.0W x 2.2 0(151 mm Lx 128 mm W x 56 mm 0) Ceiling-Mount Back Box Skirt Dimensions (BBSC-2, BBSCW-2) 7.1 diameter x 2.1 high (180 mm diameter x 57 mm high) Wall-Mount Trim Ring Dimensions (sold as a 5 pack) (TR-HS, TRW-HS) Sr Lx 4.8W x 0.35"D (145 mm Lx 122 mm W x 9 m 0) Ceiling-Mount Trim Ring Dimensions (sold as a pack) (TRC-HS, TRCW-HS) 6.9- diameter x 035 high (175 mm diameter x 9 mm high) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. P.5, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AO5O35.O7 UL Current Draw Data v1U Strobe 1T Current hDraw Imy1pIj 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Standard 15 123 128 66 71 Candela Range 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 28 8-17.5 Volts 16-33 Volts Sound Pattern d8 8-17.5 Volts DC FWR 16-33 Volts DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-temporal High 57 56 69 75 Non-temporal Medium 42 50 60 69 Non-temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 DC 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low UL Max. Current Draw (ritA 132 RMS), 2-Wire Horn 154 Strobe, H16h 80 Candela 90 Range 105 (1357185 cd) 161 184 202 211 DC Input 16-33 Volts 135 150 .177 185 FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 753 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobe. AGO35W7 Strobes SCR Strobe, Standard cd, Red SCRH Strobe, High cd, Red SCW Strobe, Standard cd, White SCWH Strobe. High cd, White Horns HR Horn, Red HW Horn, White Accessories BBS-2 Back Box Skirt, Wall, Red BBSW-2 Back Box Skirt, Wall, White BBSC-2 Back Box Skirt, Ceiling, Red BBSCW-2 Back Box Skirt, Ceiling, White TR-HS Trim Ring, Wall, Red TRW-HS Trim Ring, Wall White TRC-HS Trim Ring, Ceiling, Red TRCW-HS Trim Rinn. Ceilino. White Advance Dimensions - -ice 5. Wall-mount horn strobes Ceiling-mount horn strobes FEW Wall back box skirt Ceiling back box skirt SpectrAlert Advance Ordering Information Model 'ijri. Wall Horn Strobes P2Rt 2-Wiie Horn Strobe, Standard cdt, Red P2RH 2-Wire Horn Strobe, High cd, Red P2W 2-Wire Horn Strobe, Standard cd, White P2WI-1 2-Wire Horn Strobe, High cd. White P4R 4-Wire Horn Strobe, Standard cd, Red P4RH 4-Wire Horn Strobe, High cd, Red P4W 4-Wire Horn Strobe, Standard cd, White Wall Strobes SR Strobe, Standard cd, Red SRH Strobe, High cd, Red 5W.Strobe, Standard cd, White SWH Strobe, High cd, White Ceiling Horn Strobes PC2R* 2-Wire Horn Strobe, Standard cd, Red PC2RH 2-Wire Horn Strobe, High Cd, Red POW' 2-Wire Horn Strobe, Standard cd, White PC2WH 2-Wire Horn Strobe, High cd, White PC4R 4-Wire Horn Strobe, Standard cd, Red PC4RH 4-Wire Horn Strobe, High cd, Red PC4W 4-Wire Horn Strobe, Standard cd, White Notes: Add -P to model number for plain housing (no 'FIRE' marking on cover), e.g., P211-R I Add -SP'to model number (or FUEGO marking on cover, e.g.. P2R-SP. 'Standard cd'rcfers to strobes that include IS, 15/75.3Q 75,95, It O. and 115 candela senings.'IIigh crrefcrs to strobes that include 135, ISO, 177, and 185 candeb settings, t"\ 5)'S7EII1 . Ssvent,ao 3825 Ohio Avenue. St. Charles, IL 60174 SENSOR-) Phone: 800-SENSOR2 Fax: 630-377-6495 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:188 Page 1 of I CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: System Sensor, Unincorporated Div. of Honeywell Int'l Inc., 3825 Ohio Avenue, St. Charles IL '4 Contact: Trish Linhart (630) 377-6580 ext. 1185 Fax (630) 377-7245 Trish.Linhart@systemsensor.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, 134W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P" for plain housing with no lettering. "K" suffice models are suitable for outdoor applications at temperatures from -40 Degrees F to +151 Degrees F (-40 Degrees C to +66 Degrees C) and are rated NEMA 4X* when used with the System Sensor weather proof back boxes models SA-W!313 (Wall), *SA..WBBW (Wall), SA-WBBC (Ceiling) and *SA.WBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8 - 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as strobe lights suitable for hearing impaired applications when used with separately listed compatible fire alarm control units. Suitable for indoor or outdoor use, ceiling or wall mount. The audible units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to 'listee's Installation Instruction Manual for details. "Rev. 12-01-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 30, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division SYSTEM SENSORS PIBV2 Supervisory Switch System Sensor's P/B V2 supervisory switch monitors the open position ofpost indicator and butterfly control valves. Easy single side conduit entry Adjustable length actuator with breakaway feature Built to accommodate up to 12 AWG wire Two sets of SPDT contacts enclosed in a durable terminal block 100 percent synchronization activates alarm panel and local bell simultaneously Operating temperature range -40°F to 120°F (-40°C to 49°C) Tamper resistant cover screws Agency Listings MEA LISTED APPROVED approved 5739 C6169 7770-1653118 OWaABM 167 9 Robust Construction: The P1BV2's rugged housing is intended for indoor and outdoor use. When installed with the actuator in the vertical position, the PIBV2 is NEMA 313 rated per UL. Application Flexibility: The PIBV2 features a flexible design, whici accommodates post indicator, butterfly, and many other types of wall post, recessed wall post and pressure reducing valves. The PlBV2's unique bi-directional actuator allows the unit to be installed in either rising or falling flag installations. Simplified Installation: Installation is made easier with the PIBV2's single side conduit entrance. By providing a direct conduit pathway to the electrical source, right angle fittings are not required. Installation is further simplified by the PlBV2s adjustable length actuator with a convenient breakaway feature for installation on shorter valves, This eliminates the need for cutting the shaft. Reliable Performance: The PIBV2 has 100 percent synchronization which activates the alarm panel and local bell simultaneously. In addition, the switch is designed to operate in temperatures ranging from -40°F to 120°F (-40°C to 49°C). The PIBV2 is equipped with tamper resistant cover screws to prevent unauthorized entry. Inside, two sets of SPOT (Form C) synchronized switches are enclosed in a durable terminal block to assure reliable performance. Features NEMA 311 rated enclosure Bi-directional actuator PIBV2 Specifications 1igIIflX!LL•Iflfl .41.Jfl.tIILW I! tJI Model shall be model number PIBV2 Post Indicator Butterfly Valve supervisory switch as manufactured by System Sensor. P18V2 shall be installed on each valve as designated on the drawings and/or as specified herein. Switches shall be mounted so as not to interfere with the normal operation of the valve and shall be adjusted to operate within two revolutions of the valve control or when the valve flag has moved no more than one-fifth of the distance from its normal position. The mechanism shall be contained in a weatherproof die cast metal housing, which shall provide a side entrance for W conduit and incorporate a ½ NPT nipple for attachment to the valve body. A grounding provision is provided. The switch assembly shall include two switches each with a rated capacity of 10 Amp @ 125/250V AC and 2.5 Amp @ 24V DC.The cover shall contain tamper-resistant screws for which a security wrench will be provided with each switch. PI8V2 shall be Underwriters Laboratories listed for indoor or outdoor use. The PIBV2 shall be Factory Mutual, CSFM, and MEA approved. Physical Specifications O"rating Specifications Overall Switch 4WH x 3½W x 31A1) Contact Ratings Two sets of SPDT (Form C) Dimensions (10.8cm x 8.9cm x 8.2cm) 10.0 A @ 125/250V AC; 25 @6/1 2/24V DC Shipping Weight 2 lbs. (0.9 kg) Enclosure Rating UL indoor/outdoor NEMA 311 when mounted with the actuator vertical Operating Temperature -40°F to 120°F (-40°C to 49°C) Cover Tamper Switch Standard with ULC model Range Optional for UL model, part no. 546-7000 Maximum Stem Extension 3s/32'(8.0 cm) Service Use Automatic Sprinkler: NFPA 13 One orTwo Family Dwelling: NFPA 13D Residential Occupancies up to 4 stories: NFPA 13R National Fire Alarm code: NFPA 72 Mounting ½ NPT nipple . Warranty 3 years, Conduit Entrances One single side open for W conduit U.S. Patent No. 5,213,205 Electrical Connections for PIBV2 PIBV2 Mounting Top View The following are examples of Switch I . acceptable mounting positions: . I CONTACT RATINGS Switch 2 Jh'...rt..iJ" I l25l25OVACi IOAMPS I tF Strip oau ge I 24 VDC I 2.5 AMPS I Sup. Switch Sup. Switch Actuator Vertical (Down) Actuator Horizontal to nonslionceablo IMM-M end.ot-iine resistor The following mounting position is not acceptable: zone of listed FACP IMM _________________ __________ P-1 HHl __________ cam Go cam Cam Typical FACP Connection 1P o Actuator Vertical to power source boil Break wIre as shown for supervIsion compatible (Pointing Up) IHH_P-q____________ with bell coo of connection. DO NOT allow stripped wire leads to extend beyond switch Actuating Arm Breakaway Feature: housing. DO NOT loop wires. Typical Local Boil Connection Ordering Information No. Description PIBV2 Post Indicator/Butterfly valve supervisory switch PI8V2A Post Indicator/Butterfly valve supervisory switch (ULC model) Accessories . A3010-00 Replacement hardware kit (wrenches, screw pack) WFDW Replacement tamper proof wrench for cover 546-7000 Cover tamper switch kit HEXW Replacement hex wrench 507-66-XX Tamper screws for cover "\ 5}5TE7 3825OhioAvenue.St.Charles,1L60174 RoductTpn¼aT IrrschangewiIheuTneTicswI sWetn3emwanfz, SENSOR" Phone: 800-SENSOR2 . Fax: 630-377-6495 A05.0197O09. 11106. 1676 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION MARKING: - APPROVAL: NOTE: 7770-1653:118 Page 1 of 1 Valves/Switches System Sensor, Unincorporated Div of Honeywell Int'l Inc., 3825 Ohio Ave, St. Charles, IL 601 Contact: Trish Linhart (630) 377-6580 ext 1185 FAX (630) 377-7245 Models PIBV2 and OSY2 valve supervisory switches. Suitable for outdoor use. Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model designation, electrical rating and UL label. Listed as valve supervisory switches for use in fire sprinkler systems. Suitable for outdoor use. Formerly 7770-1209:149 06-17-05 - . This listing is based upon technical data submitted by the applióant. CSFM Fire Engineering staff has reviewed the test and/or other data but does not make an independent verification of any claims. This listing is not an endorsem' recommendation of the item listed. This listing should not be used to verify correct operational requirements or insta criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNt SU, ZUUV Listing Expires June 30, 2010. -- Authorized By: FRANCIS MATEO, Program Coordinator. Fire Engineering Division or