Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2426 TOWN GARDEN RD; ; CBC2018-0543; Permit
PERMIT REPORT rc ity of Qarlsbad- Print Date: 10/15/2020 Permit No CBC2018-0543 Tenant Improvement Job Address: 2426 TOWN GARDEN RD, CARLSBAD, CA 92009 Permit Type: BLDG-Commercial Work Class Parcel #: 2132601000 Track #: Valuation: $ 105,000.00 Lot U: Occupancy Group: Project U: #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Plan Check U: Status: Applied: Issued: Finaled Close Out: Inspector: Final Inspection: Closed - Expired 09/26/2018 12/11/2018 Project Title: Description: VIASAT: (BLDG 14) INSTALL HIGH DENSITY MOBILE AND FIXED SHELVING SYSTEMS Property Owner: CoApplicant: LEVINE INVESTMENTS LP INTERRA FURNISHINGS INC 2801 E CAMELBACK RD, U 450 1550S COAST HWY, U STE 202 PHOENIX, AZ 85016 LAGUNA BEACH, CA 92651-0000 (602) 248-8181 (949) 497-0277 FEE AMOUNT BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-COMMERCIAL $643.75 $450.62 $89.00 .$55.00 $5.00 $29.40 Total Fees: $ 1,272.77 Total Payments To Date: $ 1,272.77 Balance Due: $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-2700 1760-602-;8560 f I www.carlsbadca.gov ITHE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: []PLANNING DENGINEERING DBUILDING EIFIRE DHEALTH DHAZMATIAPCD I Building Permit Application Plan Check No. Est. Value ' /Iç ôc22 4rCity f 1635 Faraday Ave., Carlsbad, CA 92008 CdrIsbad Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. Deposit email: building@carlsbadca.gov Date JOB www.carlsbadca.gov ADDRESS ADDRESS 22.tTcu)_ (lard.oj\ Carlsbad CA 92009 I SUITEC/SPACE#/UNITU I Building 141 IAPN 19A - 55 - 19A - 54 .T/PROJECT U I LOT U I PHASE U U OF UNITS U BEDROOMS I U BATHROOMS TENANT BUSINESS NAME CONSTR. TYPE 00C. GROUP 20180019 I I I 4 I N/A N/A I N/A VIA SAT I New I DESCRIPTION OF WORK: include Square Feet of Affected Area(s) High density mobile and fixed storage shelving systems. Square Feet: 5727 P, /o'S,aoo EXISTING USE I PROPOSED USE RAGE (SF) PATIOS(SF) lAIRCONDFIONING IFIRESPRINKLERS N/A Storage 7 N/A IDECKS(SF) NIA N/A I FIREPLACE sD# NO YES NO YESNOE APPLICANT NAME- Primary Contact Interra Furnishings PROPERTY OWNER NAME Levine Investment! Via Sat ADDRESS 1550 5 Coast Hwy, Suite 202 ADDRESS 2501 Gateway Rd, Carlsbad CITY STATE ZIP CITY STATE ZIP Laguna Beach CA 92651 Carlsbad CA 92009 PHONE lF( PHONE 9492281803 I 4802399586 EMAIL EMAIL viqqo(interradesiqns.com c_ryan.hatch(viasat.com DESIGN PROFESSIONAL CONTRACTOR BUS. NAME Interra Furnishings ADDRESS ADDRESS 1550 5 Coast Hwy, Suite 202 CITY STATE ZIP CITY STATE ZIP Laquna Beach CA 92651 PHONE FAX PHONE FAX 8582010674 EMAIL EMAIL viggo(interradesigns.com STATELIC.0 I CLASS CITY BUS. LIC.# jSTATELIC.0 1002343 I C61-D34 I 4t(..a-I . 4(01N I (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). 00101303 (0O90019 Workers' Compensation Declaration: I hereby affirm under penalty of pe4ury one of the following declarations: / I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. / I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co. Security National Insurance CO Policy No. SWC1183077 expiration Date 0210512019 i section need not be completed If the permit is one hundred dollars ($100) or less. / Certificate of Exemption: I certify that in onnance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of Califomia. WARNING: Failure to secure r rite compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, darry es a ro d f0r action 3706 of the Labor code, Interest and attorney's fees. £ CONTRACTOR SIGNATURE ' . DAGENT DATE 15/OZ!// ®&0(Q ®0( I hereby affirm that I am exempt from Contractor's Ucense Law for the foiowirig reason: [J I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not Intended or offered for sale. If, however, the building or Improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). [1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). [J I am exempt under Section _____________Business and Professions Code for this reason: 1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement. DYes [:]No 2.l(have / have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name address! phone/contractors' license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/address / phone/contractors' license number): I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name! address! phone! type of work): .PROPERTY OWNER SIGNATURE . []AGENT DATE C®P((!?Q 90006 CO®) l®ff )®O®&tO OO)@ (POOMOV6 ®(S? Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? DYes 0 No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? DYes 0 No Is the facility to be constructed within 1000 feet of the outer boundary of a school site? DYes 0 No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. (®(??O®ti ()1DO1J® €cj I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address OJiY O011D®J IcertifythatI have read the application and state0vitthe above information is con ctandthatthe Information on the plans is accurate.Iagreeto complywfth all Ctyo thnanoes and State Im relatingto bLdIthngconstruon. I hereby authorize representaliveof the Cityof Carte to nterupon the above mentioned propeilyfor inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL UABILITIES, JUDGMENTS, COST XPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavationfftpp deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Buildi nd provisions ofthis Code shall expire by limitation and become null and void I the building or ark authorized by such permit is not commenced Wthin 180days from the date0fsuth permit orifthebu ing a such is suspended or abandoned at any time afterthe ark is commenced for a period ofl8o days (Section 106.4.4 Uniform Building Code). APPLICANT'S SIGNATURE DATE 01 102olly Permit Type: BLDG-Commercial Application Date: 09/26/2018 Owner: LEVINE INVESTMENTS LP Work Class: Tenant Improvement Issue Date: 12/11/2018 Subdivision: Status: Closed - Expired Expiration Date: 06/17/2019 Address: 2426 Town Garden Rd Carlsbad, CA 92009 IVR Number: 14205 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete 1211712018 1211712018 BLDG-14 078919-2018 Failed Paul Burnette ReinspectiOn Complete Frame/Steel/Bolting/ Welding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 12118/2018 1211812018 BLDG-11 079208-2018 Passed Andy Krogh Complete FoundationlFtg!Pier s (Rebar) - October 15, 2020 Page 1 of I April 16, 2019 city of Carlsbad LEVINE INVESTMENTS LP 2201 E CAMELBACK RD, 650 PHOENIX, AZ 85016 RE: BUILDING PERMIT EXPIRATION PERMIT TYPE: BLDG-Commercial, Tenant Improvement PERMIT NUMBER: CBC2018-0543 ISSUE DATE: 12/11/2018 ADDRESS: 2426 Town Garden Rd Carlsbad, Ca 92009 Our records indicate that your building permit will expire by limitation of time on 06/17/2019. 18.04.030 Section 105.5 amended - Expiration: Every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 calendar days from the date of such permit, or if the building or work authorized by such permit is stopped at any time after the work is commenced for a period of 180 calendar days, or if the building or work authorized by such permit exceeds three calendar years from the issuance date of the permit. Work shall be presumed to have commenced if the permittee has obtained a required inspection approval of work authorized by the permit by the Building Official within 180 calendar days of the date of permit issuance. Work shall be presumed to be stopped if the permittee has not obtained a required inspection approval of work by the Building Official within each 180 day period upon the initial commencement of work authorized by such permit. Before such work can be recommenced, a new permit shall be obtained to do so, and the fee therefore shall be one half the amount required for a new permit for such work, and provided that no changes have been made or will be made in the original plans and specifications for such work, and provided further that such suspension or abandonment has not exceeded one year. In order to renew action on a permit after expiration, the permittee shall pay a new permit fee. Any permittee holding an unexpired permit may apply for an extension of time within which work may commence under that permitwhen the permittee is unable to commence work within the time period required by this section for good and satisfactory reasons. Please check below indicating your intentions and return this letter to us. 0 Project abandoned. A new permit will be obtained prior to commencing work. 0 Permit 180 day extension request, with written explanation including phone number and email address. Request will not be considered without explanation 0 Renewalpermit requested. If the project has been completed and only a final inspection is needed, please call the inspection request line at (760) 602-2725. If you have any questions, please contact the Building Inspection Division at 760-602-2700. Community & Economic Development Building Division 1 1635 Faraday Avenue, Carlsbad, CA 92008-7314 1 760-602-2700 1 760-602-8560 I' I www.carlsbadca.gov EsCd A SAFEbuilttompany DATE: 11/29/2018 UAJPLICANT JURIS. JURISDICTION: ,City-ofCarlsbacL PLAN CHECK #.: CBC2018-0543 SET: II PROJECT ADDRESS: 2426 Town Garden PROJECT NAME: Storage Racks for Viasat Bressi Ranch-Bldg. 14 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. E11 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. E The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: EsGil staff did not advise the applicant that the plan check has been completed. LI EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: '-iq Email: Mail Telephone Fax In Person REMARKS: 1. Only one complete set of the plan was submitted to Esgil Corp. 2. City to filed verify that the path of travel from the handicapped parking space to the rack area and the bathroom serving the rack area comply with all the current disabled access requirements. By: David Yao Enclosures: EsGil 11/16/18 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax(858)560-1576 EsGil A sAFEbuilCCompany DATE: 10/8/2018 13 APPLICANT U JURIS. JURISDICTION: City of Carlsbad PLAN CHECK #.: CBC2018-0543 SET: I PROJECT ADDRESS: 2501 Gateway Rd. PROJECT NAME: Storage Racks for Viasat Bressi Ranch-Bldg. 14 LII The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. LI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Interra Furnishings EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: s Telephone #: 949-228-1803 Date cont a jDT171(by.4 ) Email: viggointerradesigns.com Mail elephone Fax In Person LI REMARKS: By: David Yao Enclosures: EsGil 10/1/18 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad CBC2018-0543 10/8/2018 GENERAL PLAN CORRECTION LIST JURISDICTION: City of Carlsbad PLAN CHECK #.: CBC2018-0543 PROJECT ADDRESS: 2501 Gateway Rd. DATE PLAN RECEIVED BY DATE REVIEW COMPLETED: ESGIL: 10/1/18 10/8/2018 REVIEWED BY: David Yao FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. The approval of the plans does not permit the violation of any state, county or city law. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? L3 Yes UNo City of Carlsbad CBC2018-0543 10/8/2018 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. Sheet 001 and 002 of the plan shows the rack A, B, C, K .... etc. Provide complete construction details for all racks(i.e. upright size, beam size, bracing size, and all connecitons... etc) 2. All sheets of the plans and the first sheet of the calculations are required to be signed by the licensed architect or engineer responsible for the plan preparation. Provide a statement on the Title Sheet of the plans, stating that this project shall comply with the 2016 California Building Code which adopts the 2015 IBC. The calculation provided shows 48" depth and 74" width rack. Does this most critical condition? The plan (001 and 002) shows all different racks. Provide a note on the plans indicating if any hazardous materials will be stored and/or used within the building which exceed the quantities listed in IBC Tables 307.7(1) and 307.7(2). The following design loads shall be clearly indicated on the construction documents. (Section 1603.1) Seismic design data. The following information should be provided. (Section 1603.1.5) Seismic importance factor, IE and occupancy category Mapped spectral response accelerations Ss and Si Site class Spectral response coefficients Sos and SDi Seismic design category Basic seismic-force-resisting system(s) City of Carlsbad CBC2018-0543 10/8/2018 Design base shear Seismic response coefficient(s), Cs Response modification factor(s), R Analysis procedure used. Indicate the clearance from the new racks to the existing building walls and building columns. Note on the plans that the rack design loads will be posted per Section 1.4.2 of RMI. 9. Dimension all diagonal and horizontal brace locations on the plans. Check the slab stress for the maximum transverse overturning axial load. Show the slab thickness on the plans per the calculations. Special inspection for seismic resistance shall be noted on the olans for the following conditions in accordance with Section 1707.6 City to filed verify that the path of travel from the handicapped parking space to the rack area and the bathroom serving the rack area comply with all the current disabled access requirements . Title 24, Part 2. Obtain Fire Department approval. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact David Yao at Esgil. Thank you. City of Carlsbad CBC2018-0543 10/8/2018 (DO NOT PAY - THIS IS NOT AN INVOICE) VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK #.: CBC2018-0543 PREPARED BY: David Yao DATE: 10/8/2018 BUILDING ADDRESS: 2501 Gateway Rd. BUILDING OCCUPANCY: BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) storage racks per city 105,000 Air Conditioning Fire Sprinklers TOTAL VALUE 105,000 Jurisdiction Code 1cb IBY Ordinance Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance rj Type of Review: El Complete Review D Structural Only fl Repetitive Fee Repeats El Other El Hourly d Hr. @ * EsGil Fee I $392.721 Comments: Sheet of GROSSMAN & SPEER ASSOCIATES INC. 529 HAHN AVENUE, SUITE 200, GLENDALE, CALIFORNIA 91203 —AMAJ A h~ A (1A A. - ~~/ 1/'~' qV1f'qjp yvv 8,?o ViaSat Carlsbad 'IVG p-S SUBJECT: Shelving Unit Anchorage Calculations Structural Calculations STRUCTURAL ENGINEERS (818) 507-1020 • FAX (818) 507-1556 e-mail: engineers@grossmanspeer.com PROJECT NUMBER: 18024 - FOR: PAGE: Interra I - BY: DATE: CL 5/21/2018 DESCRIPTION PAGE # Seismic Coefficient 2 Loads 3 Movable Shelving Units Anchorage Calculations Stationary Units Anchorage Calculations 5 S Hilti Kwik HUS-EZ Allowable Tension and Shear 6 Plan and Details 7-8 —vi-p NO. 6228 Exp.3-31--20 A California registered structural engineer other than Grossman & Speer shall review the existing slab on grade or floor framing for the new shelving loads. GROSSMAN & SPEER ASSOCIATES, INC. STRUCTURAL ENGINEERS 529 HAHN AVENUE, SUITE 200, GLENDALE, CALIFORNIA 91203 (818) 507-1020 • FAX (818) 507-1556 .1 1 1 e-mail: engineers@grossmanspeer.com 18024 ViaSat Carlsbad lnterra 1 2 SUBJECT: BY: DATE: Seismic Coefficient I CL 1 5/21/2018 Seismic Loading on shelving shall be based on ASCE 7-10 Chapter 13 Seismic Design Requirements For Nonstructural Components. d on USGS website and ASCE 7-10 Sds = 0.756 (Address: 2501 Gateway Road, Carlsbad, CA 92009) ap = I (ASCE 7-10 Table 13.5-1) Rp = 2.5 (ASCE 7-10 Table 13.5-1, Anchors seismically qualified with ACI 355.2) Ip = I (ASCE 7-10 Section 13.1.3) Z = 0 (Floor height where shelving is located) h = 33 (Building height) 10" Slab on grade, normal weight concrete, ft = 4500 psi Ticient (ASCE 7-10 Section 13.3.1) Fp = 0.4*ap*Scls*Wp*(1+2*(z/h))/(Rp/lp) = 0.121 Wp Fpmax = 1.6*Sds*lp*Wp = 1.210 Wp Fpmin = 0.3*Sds*Ip*Wp = 0.227 Wp Governs Fp = 0.227 Wp Fpvert = 0.2*Sds*Wp = 0.151 Wp Per ASCE 7-10 Supplement #1, Overstrength Factor C) = 2.5 For Concrete Anchorage Controlling Combination: (0.9 - Fpvert)D + QE/1 .4 Fp = 0.227/1.4 = 0.162 Wp Fpvert= 0.151 /1.4 = 0.108 Wp GROSSMAN & SPEER ASSOCIATES, INC. STRUCTURAL ENGINEERS 529 HAHN AVENUE, SUITE 200, GLENDALE, CALIFORNIA 91203 (818) 507-1020 • FAX (818) 507-1556 e-mail: engineersgrossmanspeer.com 18024 ViaSat Carlsbad Interra 3 SUBJECT: BY: DATE: Loads and Lateral Distribution I CL 5/21/2018 Material: Paper Media Weight of material is based on.CBC 2016 Table 1607.1 Footnote n Loads shall be based on whichever is less between volume (Case 1) and length (Case 2). Shelf Depth 48" Shelf Width 74" Case 1: Wt (vol) = 33 pcf Wt/Lvl = 2510 lbs/level Case 2: Wt (length)= 132 plf Wt/Lvl = 814 lbs/level Case 2 Governs: Weight of Paper Media 814 lbs/level Est. Weight of Shelf 15 lbs/level Total Load 829 lbs/level 37 124 37 35 115 74 Shelf Clear Heights Elevation Level h (inches) WI (lb) Fp (lb) Mot (in-lb) 3 87 829 134 11684 2 50 829 134 6715 1 15 829 134 2014 LEi1p Z41:51 4U5 ZU41 Total Weight, Wp = 2487 lbs Total Overturning Moment, Mot = 20413 in-lb Fp= 0.162Wp = 403 lb Fpvert = 0.108Wp = 269 lb Trib. Factor = (Number of units)/(Number of Rails) = (9 shelf units)/(10 rails) = 0.9 GROSSMAN & SPEER ASSOCIATES, INC. STRUCTURAL ENGINEERS 529 HAHN AVENUE, SUITE 200, GLENDALE, CALIFORNIA 91203 (818) 507-1020• FAX (818) 507-1556 - I I . e-mail: engineers@grossmanspeer.com 18024 ViaSat Carlsbad Interra 4 SUBJECT: BY: DATE: Movable Shelving Units Calculations CL 5/21/2018 Forces (Sin-gle Shelf Unit, I Shelf) PJAMB = (2.5)*(1 Shelf)*(Mot) / d = 1309 lbs PDL = 0.9*0 Shelf)*W/2 = 1119 lbs PVERT = (1 Shelf)*FpvERT/2 = 134 lbs W 1 PUPLIFT = PJAMB - PDL + PVERT = 324 lbs T = PUPLIFT * Trib. Factor = 291 lbs V= (2.5)(1 Shelf)*Fp*Trib. Factor = 907 lbs Fp Using (2) 3/8" x 3-1/4" Emb. Hilti Kwik HUS-EZ @ 12" o.c. (ICC ESR #3027) 2 bolts in tension 4 bolts in shear Tallow = 2*( ICC Value)= 3139 lbs OK Vallow = 4*( ICC Value)= 5776 lbs OK (2) 3/8" Dia. x 3-1/4" Emb. Hilti Kwik HUS-EZ at 12" o.c. (ICC ESR #3027). Anchors to be installed per ICC report. Special Inspection Required JAMB PJAB h = 42 d = h - 3" = 39 I Section A-A Fp - .,nuvud 24" GROSSMAN & SPEER ASSOCIATES, INC. STRUCTURAL ENGINEERS 529 HAHN AVENUE, SUITE 200, GLENDALE, CALIFORNIA 91203 (818) 507-1020 • FAX (818) 507-1556 e-mail: engineersgrossmanspeer.conr -1 Aml A4. "h h h " A IPROJECT NUMBER: I 18024 ViaSat Carlsbad lnterra 1 5 SUBJECT: BY: DATE: Stationary Units Anchorage Calculations I CL 1 5/21/2018 O=2.5 PJAMS = (2.5)*(1 Shelf)*(Mot) I d = 2320 lbs PDL = 0.9*0 Shelf)*W/2 = - 1119 lbs PVERT — (1 Shelf) FpRT/2 - 134 lbs PUPLIFT = PJAMB - PDL + PVERT = 1335 lbs T = PUPLIFT = 1335 lbs = (2.5)*(1 Shelf)*(Fp) = 1007 lbs 3/8" Hilti Kwik HUS-EZ x 3-1/4" Emb. @ Each Post (ICC ESR #3027) 1.11 in tension 2.22 in shear Tallow = 1*( ICC Value)= 1744 lbs OK Vallow = 2*( ICC Value)= 3209 lbs OK ICC ESR #3027 Section 4.2.2 (T / Tallow) + (V/Vallow) = 1.079<1.2 OK 3/8" Dia. x 3-1/4" Emb. Hilti Kwik HUS-EZ @ Each Post (ICC ESR #3027). Anchors to be installed per ICC report. Special Inspection Required J• d = 22 GROSSMAN & SPEER ASSOCIATES, INC. STRUCTURAL ENGINEERS 529 HAHN AVENUE, SUITE 200, GLENDALE, CALIFORNIA 91203 (818) 507-1020 • FAX (818) 507-1556 e-mail: engineersgrossmanspeer.con V'v PROJECT NUMBER: 18024 PROJECT: FOR: PAGE: ViaSat Carlsbad Interra 6 SUBJECT: BY: DATE: 3/8" Diameter Hilti Kwik HUS-EZ with 3-1/4" Embedment, Allowable Tension and Shear CL 5/21/2018 For Tension: Check if concrete breakout strength in tension will govern For 3/8" diameter bolts: hef = 2.5 (Table 3, ICC ESR 3027) kcr = 17 (Table 3, ICC ESR 3027) ft = 4500 psi A = 1.00 (Normal weight concrete, ICC ESR 3027 Section 4.1.12) Nb = (k)*(A)*sqrt(fc)*(hefA1 .5) (ACI 318 Section 17.4.2.2) Nb= 4508 lbs Ncb = (Anc/Anco)*LPed,n*4.Pc,n*9)cp,n*Nb (ACI 318 Section 17.4.2.1) Due to anchors not close to the edge of slab, the Anc/Anco term will be = 1.00 4'ed,n = I (c> I .5hef, since anchor is not close to edge of slab) 9c,n = I (post installed anchors) 9'cp,n = 1 Ncb = 4508 lbs 0.75*Ncb = 3381 lbs (ACI 318 Section 17.2.3.4.4) For 3/8" Diameter bolts with 3-1/4" Embedment Pullout Strength of concrete will not govern design (Table 3 ICC ESR 3027, footnote 4) Table 3 of ICC ESR 3027 0 = 0.65 (Strength Reduction Factor for Tension, Concrete Failure Mode) Tallow = 0Nb/a a = 1.4 (ICC ESR 3027 Section 4.2.1, Seismic loading) Tallow = 1570 lbs For Shear: Check if concrete breakout strength of anchor in shear will govern Since the anchors will not be close to the edge of the slab, it won't govern Check if concrete pryout strength of anchor in shear will govern ACI 318 Section 17.5.3 Vcp = kcpNcb kcp = 2.0 (hef >= 2.5) Ncb is calculated above Vcp= 9016 lbs Check if steel strength in shear (seismic) governs (Table 4 of ICC ESR 3027): Vseis = 3110 lbs Governs 0 = 0.65 (Strength Reduction Factor for Shear, Steel Failure Mode) Vallow = 0Vcp/a a = 1.4 (ICC ESR 3027 Section 4.2.1, Seismic loading) Vallow= 1444 lbs Industrial Storage Solutions W, OWE - __ __ -P. MY 11H_ I R H I Q E"INNSM ON 11 ME-Ar W _N__G SRI MS Ila I 4 IJI . T&Jtm5C . jl~ oil _ _ I 4 - :iu 94 MONTEC Intelligent Use of Space II I, I' 11M I WWI m . ) ; o : : . 4i. •: S S ' I SNERAI3zPPOWERWMOBItRACKlNGSYS1EH HdrrBase, OkaloosaCountyll 2 TABLE OF CONTENTS SAFERAK® PRODUCTIVITY & TECHNOLOGY HEAVY-DUTY MOBILE RACKING SYSTEMS PAGE 4 EPULSE' REMOTE MONITORING SOFTWARE PAGE 18 WHY SAFERAK? PAGE 5 PROGRAMMABLE AISLE AUTOMATED FEATURES PAGE 20 STORAGE SYSTEMS COMPARISON (HART PAGE 6 CASE STUDIES THE CONCEPT PAGE 7 RETURN ON INVESTMENT PAGE 8 SOME OF OUR CLIENTS PAGE 23 MOBILE STORAGE SYSTEM BENEFITS PAGE 11 AIRBUS PAGE 24 IMMUNOTEC PAGE 26 APPLICATIONS USARMY PAGE28 INDUSTRIES PAGE 12 WHY CHOOSE MONTEL COLD STORAGE PAGE 14 INDUSTRIAL MOBILE SERIES PAGE 15 CUSTOM-BUILT FOR YOUR INDUSTRY PAGE 30 WHY CHOOSE MONTEL? PAGE 31 SAFETIES OUR MISSION PAGE 31 POWERED MOBILE STORAGE SYSTEMS SAFERAK 32P, SAFERAK 60P PAGE 16 INTERNATIONAL PRESENCE PAGE 31 AISLE LED GUARF ADVANCED SAFETY SAFERAK 32P, SAFERAK 60P PAGE 17 3 SAIERAK 31P Hydro-Oudbec, Central 1G2,OC SMIRAK 60P Strong MDI Inc. Cinema and Specialty Screens - -. MU V 0 UDJ SAFER'&K," 5wn-f EIV[ 1 CREATE MORE ROOM. NO NEED TO EXPAND. NO NEED TO RELOCATE. NO NEED TO LEASE ADDITIONAL SPACE. Discover new floor space by simply adding your existing industrial racking on top of the heavy duty industrial mobile carriages and rails. -- . I •_4P I SAFRAK Mobile Base ILFQRItUJEJ MUBILTEYMEMS_L stau iles and use the to al potenda of ypur veaIorlzo1 Pace. ave uptoO '- — —ofbvPpsP arçO% STATIONARY ONVEIfOTA(NG 4 MILITARY STORAGE SOLUTIONS - - -- SAFERAK 32P Hudburt Field Air Force Base, Okaloosa County, Fl. SAFERAK 60P MOBILE PALLET RACKING SYSTEM The SAFERAK! heavy-duty high-density storage systems generate a rapid return on your investment. In addition to making better use of your existing space, you can lower your production costs by improving the organization of your materials, either raw, work-in-process, or finished products. my 0E SPACE. BE GREEN. STREAM LINE YOUR WORNFLOW. LOWER YOUR PRODUCTION COSTS. INCREASE YOUR PROFITS. We live in a four-dimensional world of length, depth, height, and time. The space we occupy is moving and alive.., in constant flux. All space, however small, has incomparable value. Any space can be organized. SAFERAK' by organizing your space, you can increase your storage capacity in the same footprint, or make available as much as 65% of your current storage space for more profitable activities, improve your productivity while lowering your production costs, and consequently increase your bottom-line profits. At Montel, we help you make Intelligent Use of Space. qv SAFERA11117. ©$L DC1 BUILT FOR DECADES THE 11051 USER-FRIENDLY HIGH-DENSITY MOBILE RACKING SYSTEM. A HIGHLY SECURE MOBILE STORAGE SYSTEM. INCREASE PRODUCTIVITY BY SAVING TIME AND COSTS. THE ONLY GOOD SOLUTION IS A CONFIGURABLE AND RECOIIFIGURABLE SOLUTION. THANKS TO PULSE REMOTE MONITORING. RATED MACHINE SAFETY STANDARDS MOUNT YOUR EXISTING RACKING OR INDUSTRIAL SHELVING ONTO MOBILIZED INDUSTRIAL CARRIAGES. GROW FROM THE INSIDE 5 PAUH RACEN SORAGE SEEKS CHARV FOR 59000 muns SAFERk PALLET RACKING _________ STATIONARY RACKING NARROW AISLE DRIVE-IN RACKING DRIVE-IN RACKING PUSH BACK RACKING STORAGE SYSTEMS RACKING FLOOR SPACE REQUIRED IN SQUARE FEET 22K MINIMAL FLOOR 41K 32K 31K 37K 32K SPACE REQUIRED VOLUME REQUIRED IN CUBIC FEET 795K MOST INIELLIGENT 1.483M 1.139M 1.082M 1.395M 1.196M USE OF VOLUME ® INVESTMENT BEST ROI $ $ $ $ $$$$$$$ FLOW TYPE FIFO FIFO FIFO FILO FILO FILO/FIFO & ACCESSIBILITY FULL ACCESS FULL ACCESS FULL ACCESS LIMITED ACCESS LIMITED ACCESS FULL ACCESS INVENTORY ROTATION .- ADAPTABILITY ADAPTABLE ADAPTABLE ADAPTABLE ADAPTABLE NOT ADAPTABLE NOT ADAPTABLE Q PALLET HANDLING & STOCK PROTECTION LEASTDAMAGES *zi frr*irir TO SUPPLIES N_1EA1.. - INS MONTEL HIGH DENSITY STORAGE SYSTEMS MAXIMIZE THE USE OF AVAILABLE SPACE, WHETHER TO INCREASE STORAGE CAPACITY, FREE UP ROOM FOR PRODUCTION OR OTHER USES, OR GET RID OF SPACE YOU DO NOT NEED TO PAY FOR. ELIMINATE THE NEED FOR MULTIPLE SPACE-WASTING STATIC AISLES. PUSH A BUTTON ON THE POWERED SYSTEM CONTROL TO OPEN THE DESIRED AISLE. Static units are mounted on mobile carriages. Mobile carriages travel on tracks. Push a button on the powered system control to open the desired aisle. fsi $I$I$I WASTED SPACE CONVENTIONAL FIXED RACKING LAYOUT. Conventional storage systems require space-wasting fixed aisles. MODES OF OPERATION Powered mobile storage systems control. Powered mobile storage systems control with PIN for restricted access. FREED Up SPACE A d WH SPACE SAVED & INCREASED PROFITS MOBILE STORAGE LAYOUT. Montel's high-density storage systems save up to 50% of your floor space inmost cases, and accommodate growth for other uses while increasing revenue. LCD touchscreen tablet control with or without PIN. Limitless customized displays. NOW 100% GREATER STORAGE CAPACITY .r.it1Il DOUBLED STORAGE CAPACITY. MAXIMIZED SPACE & INCREASED PROFITS MOBILE LAYOUT. 100% greater storage capacity within the original floor space, eliminating the need for a costly expansion or the construction of a new facility. 1' 11 1 6S F A ST NO SHREWD INVESTOR DROPS THEIR HARD-EARNED MONEY ON BREAKTHROUGH TECHNOLOGY WITHOUT CONSIDERING ITS VIABILITY. WILL SPENDING ON AN INNOVATION LIKE HIGH DENSITY MOBILE RACKING TODAY BE A LUCRATIVE BUSINESS VENTURE TOMORROW? - - _', 3 150%H FREED UP SPACE 11 lip Businesses know space can be a valuable commodity, regardless of industry. For retailers and manufacturers, a diverse product line requires places for all the additional SKUs they're charged with managing. For warehouses, extra room means extra opportunities to bring in new business and reap the benefits of demand-based vacancy rates. <<High density mobile racking systems imbue businesses with a greater sense of spatial economics)). High density mobile shelving and industrial racking technology reclaims space otherwise occupied by aisles that more often than not go unused. That means as much as 50 percent of an industrial storage area equipped with static shelving is literally squandered on space that's hardly used. Mobile racking installations can either shrink the overall storage footprint to allow for greater on-site operational freedom or effectively double a company's storage capacity without physically expanding. In either case, high density mobile racking systems imbue businesses with a greater sense of spatial economics that provides financial benefits year over year. Can mobile racking systems really keep pace with the speed of modern business? Competitive markets call for 7 investments that accelerate operations, streamline processes and eliminate waste. Outfitting an industrial facility with high density mobile racking installations not only improves logistical throughput but can push companies BUSINESSES to make more intelligent, data-minded decisions about how they conduct business. Mobile shelving coupled with optional e-Pulse remote monitoring technology works with logistics teams STAY QUICK to isolate increased traffic areas and restructure their legacy organizational strategies around adopting more 10ITH HIGH comprehensive zoning and picking methods supported by the mobile racking technology. With ePulse software, managers and supervisors can track facility movement, examine which products receive the most attention DENSITY and make small adjustments accordingly. MOBILE WHAT CAN YOUR BUSINESS DO WITH THE NEW FREED UP SPACE? R A( K 10 G Building on more room to a facility may improve gross production capabilities, but when one takes into account increases to energy footprint, construction costs and labor mandates - not to mention property rental costs, 0 insurance, taxes and maintenance - who knows when that addition will actually return real value to the company? INNOVATIRG When a warehouse or other storage facility has seemingly run out of space, expansion seems like the only solution. Thanks to mobile storage, it isn't even a contender. INSTEADQIF On the other hand, research conducted by Montel distributor revealed mobile storage modules installed throughout NAfATfl II 18,000 square feet of reclaimed warehouse space would pay for itself in under two years and return more than lJ U\i 1 L1 VII U\J $1.1 million in avoided costs alter a decade of use. Instead of increasing their size or spending money on fleeting managerial fads, businesses should simply strive to utilize the space they have more efficiently. To that end, investment in high density mobile racking systems is an investment in how well a company operates and keeps costs to a minimum. G. 6 0 COST OF M OTEL MOBILE STORAGE SYSTEM VS. ANNUAL COST OF WAREHOUSE RENT ESTIMATED WAREHOUSE LEASE - ILLINOIS PRODUCT: SAFERAK® 32P MOBILE RACKING MONTEL SAFERAK®32P MOBILE RACKING ANNUAL WAREHOUSE RENT Lease per sq ft $1.00 HVAC Cost per sq ft $1.50 Warehouse Taxes & Maintenance $0.75 Total Annual Lease Per sq ft $9.25/sq ft ROI IN 22 MONTHS Montel Mobile Storage System Investment* $240,000 Recovered Warehouse Space 14,000 sq ft Yearly Rent on Freed Up Space (14,000 sq ft x $7.00 annual rent per sq ft) $98,000 HVAC & Utilities (14,000 x $1.50 annual cost per sq ft) $21,000 Insurance, Maintenance, Taxes (14,000 sq ft x $0.75 annual cost per sq ft) $10,500 Total Savings in Leasing per Year $129,500 ROI 22 Months ROI AFTER 10 YEAR = ($129,500 x 10 Years) - $2409000 $1,295,000 Warehouse costs were too expensive compared to a Montel mobilized racking solution. * Pricing includes mobile system and installation cost. 10 YOUR CURRENT WAREHOUSE FEES ARE TOO EXPENSIVE WHEN COMPARED TO A MOBILIZED RACKING SOLUTION. HIGH-DENSITY MOBILE STORAGE SYSTEM BENEFITS Freed up valuable floor space for receiving area without increasing stockroom footprint Improved circulation paths for personnel and material handling equipment Added stockroom organization, security and cleanliness of working environment Enhanced overall efficiency and productivity as materials are more organized - easier for brand inventory control Eliminated the need for costly outside storage containers 12 .j I. '•• tUIU-U ILl IUN IiTNY ENGINEERED HIGH-DENSITY STORAGE SYSTEMS We have developed a comprehensive line-up of best-in-class high-density storage solutions that are precision-engineered to deliver lasting high-capacity storage. Their versatility makes them the movable and powered storage of choice for any industry: aerospace, automotive, defense, distribution centers, food, beverages, manufacturing and pharmaceutical plants, third-party logistics, etc. The perfect recipe for your food plant: Mantel's industrial storage systems. S Make storage a dependable link in the supply chain for your third-party logistics provider with Montel's durable, high-density industrial racking and shelving systems. LcI3 Get more space with Montel's industrial storage shelving and storage systems specially designed for the aerospace industry. Security! The only ward that will come to mind with Montel's industrial storage systems intended for the defense and military sectors. t 1J CO. 1 So that your stocks management of alcohol, liquors and beverages flows abundantly, Mantel industrial storage proposes a series of solutions adapted to your storage demands. Montel's industrial storage products which are customized for the automotive industry will allow you to maximize your space while increasing your storage capacity. Establish a customized storage so!ution in your production plant with Mantel's industrial storage solutions. An efficient distribution center! That is what Mantel industrial storage proposes with its space saving solutions adapted for your industry. 13 Maximize storage capacity with minimal wattage 01 power use. It is all about your grams per watt. Cultivate and optimize your agriculture's racking & shelving storage needs with Montel's multi-functional, high-density shelving solutions. Prescribe Mantel's industrial storage solutions to meet your pharmaceutical products plant's requirements in terms of storage. MOBILE STORAGE SYSTEM SAFERAW RP, 60P Node of Operation Powered Optional Rail Shock Resistant Powder Paint (Standard) or Stainless Steel (Optional) Temperature Criteria Above 32°F(O°C) Yes Below 32°F (0°C) to 1410000 Yes Below 14°F (-100Q to -4°F (-20°C) No SAFERA1(32P Powered Mobile Racking for Cold Storage. nil 0 D 8 -a - &9 . flCEL(® BEAT THE HEAT WITH MOBILE RACKING SOLUTIONS FOR COLD STORAGE Cold storage is nothing to shake a popsicle at. Keeping an entire inventory at a consistent temperature is an energy - and resource - intensive endeavor, but businesses that can successfully manage or even overcome these obstacles avoid financial freezer burn. There's always room to grow, even in the smallest storage facilities. Powered mobile racking for industrial cold storage environments takes into consideration every aspect that gOes into effective temperature controlled settings, preventing operations - as well as stored materials - from thawing out. &WWI D W AV DD~2 E-&-= ]V[ D SAFERA® 32P Load Capacity: 32,000 lb (14,514 kg) Capacity Per Double Rack Sections Operation: Powered Mobile Carriage Maximum Length: 100 Feet (30,5 m) SAFERA® 60P Load Capacity: 60,000 lb (21,215 kg) Capacity Per Double Rack Sections Operation: Powered Mobile Carriage Maximum Length: 120 Feet (36,6 m) 15 SAFETIES PONSFRED MOBILE STORAGE SYSTEMS SA® 32P I SAlFE1A® 60P RATED MACHINE SAFETY STANDARDS I RATED MACHINE IN ORDER TO BE COMPLIANT WITH "RATED MACHINE SAFETY STANDARDS", MONTEL HIRED AN OUTSIDE SAFETY STANDARDS FIRM SPECIALIZED IN ANALYZING SAFETY IN INDUSTRIAL ENVIRONMENTS. FOLLOWING THIS ANALYSIS, MONTEL DECIDED TO COMPLY BY OFFERING NUMEROUS STANDARD SAFETIES. SYSTEM ENTRY INFRARED INFRARED FLOOR-LEVEL SAFETY BEAMS READILY ACCESSIBLE BEAM CURTAIN BOTH SIDES OF EACH MOBILE CARRIAGE EMERGENCY STOP BUTTON 410 Carriage movement instantly stop when the system detects any beam disruption in front of the storage system. SAFEGUARDS FOR ALL MECHANICAL MOVING PARTS Photoelectric beams projecting on both sides of each aisle are mounted low on the carriage side members. MECHANICAL RATCHET BACKUP OVERRIDE Face panels emergency stop buttons are arguably the most identifiable element on SAFERAK'. All mechanical moving components are The mechanical ratchet ensures complete concealed and protected by a steel safety accessibility even in the event of a power guard to prevent inadvertent access. failure (no operational downtime). STROBE LIGHT AND BUZZER A safety alert buzzer, a visual signal and flashing notifications are provided prior to and during carriage movement. 16 OPTIONAL SAFETIES IN-AISLE EMERGENCY STOPS ALTERNATING AND OFFSET ON EACH SIDE OF AN AISLE. EN95 4-1 CATEGORY 1 COMPLIANT INDUSTRIAL PLC ON EVERY MOBILE LADDER SECURITY KEYSWITCH SECURITY PERIMETER ISO 13851 COMPLIANT Aisle Led Guard" used in Montel products cannot be deactivated, overwritten or bypassed. No sequence of button mashing or reconfiguration will shut it down. Aisle Led Guard'" places mobile shelving installations in a constant state of vigilance. IMPROVE PRODUCTIVITY Operators can easily reset SAFERAK' remotely with the rugged industrial Wi-Fi remote control. Users won't have to step out of their forklifts to reset the system. AISLE LED GUARDTM ADVANCED OPTIONAL SAFETY STI E*Tl E V 61 ADVANCED OPTIONAL SAFETY AISLE LED GUARD" COMPLETE AISLE-DETECTION PASSIVE SAFETY NOTE: RECOMMENDED FOR PUBLIC ACCESS OR HIGH TRAFFIC AREAS. AUI(DGUARU6PAIFN1Ea (USPATRII U 64OOOI(AKADAIIIffl 92,560) MONTEL REVOLUTIONIZES MOBILE STORAGE WITH AISLE LED GUARD" FOR SAFERAK 32P AND SAFERAK 60P Montel's powered mobile systems supplied with the advanced optional safety Aisle Led Guard" passive safety adds a new dimension by continuously detecting the whole floor surface footprint of an aisle. The world of high-density storage will never be the same Aisle Led Guard" represents a major watershed moment in employee safety and shrinkage prevention for industrial storage used in day-to-day operations. With nearly a century of mobile storage experience under its belt, Montel developed Aisle Led Guard' to keep industries everywhere perpetually productive, cost-effective and employee-friendly. So, how does Montel's patented Aisle Led Guard'" work and why do those features mailer to modern businesses? AISLE LED GUARDTM IN A NUTSHELL Mobile shelving and racking reduces storage footprints thanks to its collapsible architecture. However, in industries like manufacturing and logistics where processes move at lightning speed, thoughtlessly closing a mobile storage unit could pose a risk to both goods and workers. LED sensors detect people and objects in open aisles. While aisles are in use or occupied, racking modules are locked in place, thereby protecting users from injury and stored materials from damage. Regardless of what you and your organizations stores Aisle Led Guard" ensures no avoidable harm comes to any of it should it fall from your racking. SEEMS PRETTY STRAIGHTFORWARD, RIGHT? LET'S DIG A BIT DEEPER INTO AISLE LED GUARD" TO FULLY UNDERSTAND HOW NONTEL DESIGNED THE PERFECT SAFETY PRECAUTION: COMPLETELY PASSIVE Aisle Led Guard'" is 100% passive. Users do not have to remember to locate and activate any safety devices when interacting with the mobile shelving or racking system. Even with fully loaded racking, Aisle Led Guard" will protect users and objects left in the aisle without human intervention. FULL COVERAGE Where users stand in an open aisle will not impact the effectiveness of Aisle Led Guard". When Montel customers invest in powered mobile shelving or racking systems supported by Aisle Led Guard", they're putting their money into complete aisle coverage for consummate protection. No mailer where a user is located in the aisle, no matter where in the aisle a product falls, no matter if a pallet is left in the aisle, the units will not close without complete clearance. With full coverage from LED sensors, Aisle Led Guard'" protects users and objects every step of the way. FOOLPROOF DESIGN INCREASE PRODUCTIVITY WIRELESSLY Created to provide additional certainty and safety monitoring once Montel's high-density powered mobile storage systems are installed, Montel now offers i = ePulse . This remote monitoring & configuration software has the functionality and capability to manage settings remotely and monitor your high-density I powered mobile system's performance and operations with assurance. = If remote network connectivity access to Montel is granted certified technicians could monitor and configure your system remotely from their own location. ••.• •. ...i... For maximum reliability and peace of mind ePulse proactively identifies any potential issues with your system, provides quick diagnostic of the system to maximize your uptime, sends automatic email notifications of system errors. You could even decide to monitor and configure your own Montel powered mobile system 24 hours a day, every day of the year. To increase productivity & efficiency, ePuIseTM allows to collect aisle entry data for any preset period of time from your Montel powered mobile system. Once this data is analyzed for each aisle, ePulsew permits to reconfigure your powered mobile system to your preferred settings and parameters including: a - - Priority Aisle - Auto-Closing/Security Park - Auto-Spacing/Ventilation Park -Auto-Cycling - Programmable Speeds (start-up/cruising/braking) - Sequential Move, Block Move For additional security, with the collected & analyzed aisle entry data from your powered mobile system, ePulse'TM allows to reconfigure the security settings of your system at anytime. Whether it would be adjusting the programmable speeds, or remotely configuring your system to close all aisles and lock at a specific time after business hours, or open and unlock before business hours, ePulse'TM offers security with peace of mind. Montel powered systems can be operated remotely from the fingertips to your computer with the ePulseTM. The TCP/IP protocol facilitates the network connectivity from a computer to the Montel powered system. This provides reliable high-speed communication, and allows remote reconfiguring of your system using the ePulse'TM remote monitoring & configuration software. Montefs ePulseT remote monitoring & configuration software is available with SmartSpace 2P, SaleAisle RACK&ROLL 16R SAFERAK32P SAFERAK6OP LR Pulse TM Remote Monitoring Software 19 PRODUCTIVITY & TECHNOLOGY D D 0 D V 8 D ]VU D V& nn v uu IV[ &,I- DD MORE EFFICIENT THAN A MECHANICAL OR MANUAL MOBILE STORAGE SYSTEM, SAFERA(® IS A TIME-SAVER AS WELL AS A COST-SAVER. WORKSMITH 'AEERAK" 22 AFERA 60 20 fL' - I I I L t PRIORITIZING AISLES Users can increase their efficiency by configuring a specific priority aisle(s). While accessing an infrequently used aisle, SmartSpace 2P SaleAisle', RACK&ROft16P SAFERAK' 32P and SAFERAK' 60P mobile racking automatically repositions the system to your desired predetermined aisle(s). The most frequently utilized aisle(s) will be preset to reopen automatically for the next user. You can eventually reconfigure your SmartSpace 2P SafeAisle', RACK&ROLI 16P SAFERAK' 32P and SAFERAK' 60P powered mobile racking mobile system by programming aisles according to picking rates or pulls. This ensures quick access to your commonly stored materials. Program the Priority Aisle automatic feature with the PIN-Code Control or the optional ePuIse" Remote Monitoring Software. CLOSING ALL AISLES Program your system to automatically close all aisles and lock once a user exits an aisle, or after a preconfigured period of inactivity. Configure your system to close all aisles and lock at a specific time after business hours, or open and unlock before business hours. OPERATE THE MOBILE STORAGE SYSTEM REMOTELY WITH AN INDUSTRIAL RUGGED WI-Fl REMOTE CONTROL Forklift operators can operate the mobile storage system remotely with a commercial or industrial rugged remote control mini tablet. The mobile storage system can also be operated remotely from your computer with the optional ePulseTM remote monitoring software. ePuIseTM REMOTE MONITORING SOFTWARE ePulse'TM provides many avenues to monitor potential issues with your system, provides quick diagnostics of the system to maximize your uptime, sends automatic email notifications of system errors, and ensures constant monitoring 24 hours a day, every day of the year. The Tcp/Ip protocol facilitates the network connectivity from a computer to the Montel powered mobile storage system. OPERATING AISLES REMOTELY Forklift operators can operate SmartSpace 2R SafeAisle', RACK&ROLL 16R SAFERAK 32P and SAFERAK," 60P powered mobile racking using a Wi-Fi remote control mini tablet. SmartSpace 2P, SafeAisle', RACK&ROLL 16P, SAFERAK' 32P and SAFERAK 60P mobile racking can also be operated from your computer with the optional ePuIse Remote Monitoring Software. ePuIseTM Remote Monitoring and Configuration Software allows onsite, and offsite monitoring if remote network connectivity access is granted, of any installed mobile storage system providing peace of mind to our customers. If authorized to access remotely the client's network, Montel certified technicians could be notified instantly by email in the unlikely event there is an issue with a powered storage system, and could provide statistics of the ins and outs of each aisle thereby providing data such as which SKUs are moving faster or slower, allowing to program automated priority aisles, adjustable speed settings (soft start, cruising speed, slow stop), adjustable aisle clearance between the mobile storage system, PIN codes management, etc. At anytime, the ePuIseTM allows you to reconfigure your powered mobile racking to your preferred settings and parameters, and ensures performance and operations with insurance. ePulsetm allows numerous configurable operations to improve productivity and security remotely. 21 i L.3 0 i . Ltd. Ll" 22 uJ n PIONEER OF HIGH-DENSITY MOBILE SHELVING STORAGE SYSTEM SOLUTIONS IN NORTH AMERICA, MONTEL HAS INSTALLED THOUSANDS SYSTEMS IN OVER 68 COUNTRIES AROUND THE WORLD. MONTEL IS REPRESENTED BY A WORLDWIDE NETWORK OF DISTRIBUTORS. WHETHER LARGE OR SMALL INSTALLATIONS, MONTEL DELIVERS MORE THAN A STANDARDIZED PRODUCT. BUILT FOR DECADES Leverage engineered storage solutions that are built to last and optimize your operations with Montel's Industrial mobile storage systems. Power. Performance. Strength. Durability. Whatever industrial applications you are involved in, those are words to live by. You need powerful, high-performance production and assembly systems and equipment that have the strength and durability to handle big loads and high volumes in pressure-packed environments. At Montel, we believe industrial storage systems should meet the same rigorous, tough standards for handling supplies, tools, fixtures, service parts, packaging, samples and beyond. WE BUILD SATISFACTION We have developed a comprehensive line-up of best-in-class mobile high-density racking and shelving solutions that are precision-engineered to deliver lasting high-capacity storage. Their versatility makes them the movable and powered storage of choice for any industry: aerospace, automotive, defense, distribution centers, food, manufacturing and pharmaceutical plants, third-party logistics, etc. Harley Davidson uses Montel's SAFERAK' 32P powered mobile storage units to properly store maintenance parts. This allowed Harley Davidson to provide faster and better customer service. 9 Menomonee Fans. WI SAFERAK' 32P saved Airbus nearly 60,000 sq. It of storage space by consolidating two warehouses into one. That meant significant vacancy reclamation, as well as dedicating what was once storage to other needs, all without major construction or renovation. 9 ASHBURN, VIRGINIA, USA :"""1ill United States Army was experiencing an outage of its storage space and wanted to optimize its warehouse storage space instead of building a new facility. Unites States Army grew from the inside so they did not need to expand. 9 UNITED STATES ARMY, USA Immunotec's continual upward growth required additional inventory space and storagre. The objectives were to increase storage capacity by 60% and enhance productivity by relocating fast moving SKU's to another section of the warehouse thus reducing pick routes. t t Tç LL 'LLI Zenith Aviation almost triples storage in the same footprint. Zenith traded its four static industrial racks for 10 SAFERAK' 32P powered mobile racking units. Zenith saved 12,000-plus cubic feet of space in its warehouse while more than doubling its rack availability. 9 Fredericksbirg,VA Canadair-Bombardier doubled its storage capacity, increased its workflow and witnessed a boost of productivity in the factory once SAFERAK' 60P mobile storage system was installed. SAFERAK' eliminated downtime risks by installing powered mobile solutions that work even during a blackout. Each unit contains a surge protector that guards the system from voltage spikes and can be moved easily by hand with a ratchet tool provided with the system. site inventory storage was inconvenient in terms of transit, control, costs, security, accessibility and storage conditions. IBM saved on heating, cooling and ventilation costs with less warehouse space using SAFERAK' 60P i 23 CASE STUDIES GETULES1TUS HTE AIRBUS FINALLY SAW ITS STORAGE GOALS REALIZED ONCE MONTEL BROUGHT SAFERAK 32P POWERED MOBILE RACKING INSTALLATIONS TO ITS MATERIALS CENTER IN ASHBURN, VIRGINIA. Industrial-sized storage problems require industrial storage solutions. Who would know better than a company like Airbus, a world leader in aerospace innovation? Airbus had expectations for storage that his legacy system just wasn't reaching. He saw plenty of opportunities but knew he couldn't achieve any of them without a smarter, more efficient way to store his stock of oversized, 1,000-pound parts. However, once Montel brought SAFERAK 32P powered mobile racking installations to their materials center in Ashburn, Airbus saw their storage goals realized. What were those goals, and how did SAFERAK soar above Airbus's expectations? 24 S*FWSU POW(REDMOIL(PACKINGCANIMPROV(PROOUC1M1YBYCONSRVINGSPA(EFORWARHIOIJSEV,RKERS %AIRBUS 9 ASHBURN, VIRGINIA, USA SAFERAK 32P INDUSTRIAL POWERED MOBILE RACKING AEROSPACE INDUSTRY SAFERAK® saved Airbus 60,000 square feet of storage space. MAXIMIZE STORAGE CAPACITY When Mantel arrived on the scene, Airbus's Ashburn warehouse teams needed approximately 104,000 square feet of storage to do their jobs. Or so they thought. After redesigning the layout of this materials facility with SAFERAK industrial mobile racking systems, Montel showed Airbus it could do more with far, far less. SAFERAK's collapsable, accordion-like architecture saved Airbus nearly 60,000 square feet of storage space. That meant significant and immediate vacancy reclamation, as well as the capability to dedicate what was once storage to other needs, all without major construction or renovation. Airbus sacrificed nothing to achieve those gains. In fact, the company's new powered racking system gave them a total of 300,000 cubic feet of storage and the capacity to hold up to 3 million pounds!. MEET ENVIRONMENTAL OBJECTIVES In one instance, Montel and SAFERAVI storage systems did more than just free up space. They helped Airbus consolidate two 30,000 square foot warehouses into one. In doing so, Airbus was able to meet its environmental objectives regarding land use. Sustainability eludes many in the industrial sector, but intelligent racking solutions gave Airbus the freedom to go green while saving money and maintaining its core processes. LOWER OPERATIONAL COSTS So we know Airbus optimized its storage space across the entire Ashburn facility thanks to Montel's SAFERAK 32P powered mobile storage units. But how did this massive change to its warehouses affect productivity? For starters, SAFERAK eliminated downtime risks by installing powered mobile solutions that work even during a blackout. Each unit contains a surge protector that guards the system from voltage spikes and can be moved easily by hand with a ratchet tool provided with the system. Imagine that: In the event of an outage, a 33-foot mobile rack loaded with tons of materials can be moved manually by a single warehouse worker. In the long run, a smaller storage footprint will allow warehouse workers to better organize their tasks andreduce order completion times. Better still, Airbus has the potential to save considerably on heating, cooling and ventilation costs with less warehouse space to worry about. But perhaps best of all, Mantel was able to install SAFERAK at Airbus's Virginia materials center without any interruption to its operations. 25 KV NV u a ii GUUL1E qnT _1Th ORO '1? EI NINE M ME M2 ON-SM U1©1? Emualv cosu3 mumU3 assmur 2m ona 26 Immunotect SAFERAK® 32P INDUSTRIAL POWERED MOBILE RACKING PHARMACEUTICAL INDUSTRY " The Montel SAFERAK® 32P mobile racking has significantly increased our storage capacity, stimulated the reorganization and rezoning of our warehouse, reduced our picking routes thus increased our overall effectiveness. The system instantly helped our employees become more efficient. 55 CHALLENGES Immunotec's continual upward growth required additional inventory space Additional SKUs introduced to the marketplace required additional storage OBJECTIVES Increase storage capacity by 60% Increase productivity by relocating fast moving SKUs to another section of the warehouse thus reducing picking routes SOLUTIONS Montel SAFERAV 32P industrial powered mobile storage systems mounted on pallet rack for heavy-duty storage. Length: 58' mobile carriages Aisle width: 8.75' System height: 20' Load capacity: 30,000 lb per section With the assistance of its local Authorized Montel Distributor, Prisma Storage Solutions, Montel provided the following mobile racking systems: PRODUCT FEATURES Impact-resistant (against lift-trucks) infrared floor-level safety sweep on both sides of the aisles protecting users and materials. PIN-controlled access for added security Infrared adjustable proximity sensor to adjust the distance between each carriage. Impact-resistant zinc housing face panel controls Sealed membrane controls preventing dust infiltration, minimizing future maintenance. BENEFITS Significant short-term and long-term saving. 60% space saving. Provided room more inventory due to a significant sales growth. Condensed inventory storage. Storage space for more skus introduced to the marketplace. Overall improved efficiency and productivity (materials are more organized, less handling, easy to inventory control, accessibility, etc.). Added security. 27 KV cz rn DE$ t,iITh 1 SiG1FICit1 VOLUViE INCREASE FOR ITS STRATEGIC AND CRITICI!. NATERIAL STORED TO CIP1CIiV, UITD STATES 11Y UJAS ERPERIMICING AN OUTAGE OF IlS STORAGE SPACE. 28 9 UNITED STATES ARMY, CA, USA SAFERAK@ 32P INDUSTRIAL POWERED MOBILE RACKING MILITARY & DEFENSE INDUSTRY ' We grew from the inside thereby no need to expand. ,, CHALLENGES PRODUCT FEATURES Rather than proceeding with the building of a new warehouse facility, With the assistance of its local Authorized Montel Distributor, United States Army wanted to minimize construction costs while BMH Equipment Inc., Montel provided the following custom optimizing its warehouse storage space. designed military storage solution: SOLUTIONS ' Powered SAFERAV 32P compact storage system with pallet racks on motorized carriages. A state-of-the-art high-density storage system was proposed to United Mobile storage racks designed for a load capacity performance States Army with 25-foot carriages for a maximized space utilization of 30,000 pounds within its warehouse. Integrated built-in control panels to operate the system and display its status. Proximity detectors controlled electronically. 2 foot-level infrared safeties for each aisle. Flashing light and horn safety features that provide visual and audible warnings. 29 Established in 1924, Montel pioneered high density mobile storage systems providing cost-efficient storage solutions using less space. CUSTOM-BUILT FOR YOUR INDUSTRY WE'VE MANUFACTURED AND INSTALLED THOUSANDS OF PROJECTS AROUND THE WORLD. .1 PetsFoodTX SMARISHELI 4-POST Honda Dealerships, NorlhAmerka SDFEAISLE POWERED Pittsburgh Penguins, Pittsburgh, PA HYBRID SHELVING SYSTEM MOBILE SHELVING SYSTEM - r I . 1 0 I I I ( J ) I.' SARIAISLI POWERED Hospital Central Sterile Supply Department HOBILEX MEOTATECAL-ASSISI Williams Selyem WInery, Healdsbnrg, CA SAFERAK 31P POWERED (old Storage. Swiftwater, PA MOBILE SHELVING SYSTEM MOBILE SHELVING SYSTEM MOBILE RACKING SYSTEM FOR COLD STORAGE WHAT ELSE DO WE DO? STORAGE SOLUTIONS THAT HELP YOU TO GROW FROM THE INSIDE, OPTIMIZE AND GET RESULTS. kR~ HOBILESIORAGE SHELVING SYSTEMS IllDUS1RIALMOBUIARDRAWERS CABINETS WORKBENCHES HATIGING STORAGE SYSTEMS SCREENS B PANELS 30 HOBBIX MECHANICAL-ASSISII WIIH4D WIDE SPAN RACKING Ni\ M.fr' L 47 SAN DIEGO REGIONAL I OFFICE USE ONLY HAZARDOUS MATERIALS IPLAN CHECK # IRECORDlD#_______________________________ OC QUESTIONNAIRE I BPDATE I I Businesq Name Business Contact &47t/>g11t '1 Telephone # - 06 oig Project Address City State 6,123?V111-f 9Z2 Zip Code 7,21.4 I APN# I Mailing Address City State Zip Code I Plan File# rt Contact 2 , -mail ,-ma Telephone U me following questions represent me facility's activities, NOT the Specific project description. PART I: FIRE DEPARTMENT -HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: (not required for projects within the City of San Diego): Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Occupancy Rating: Facility's Square Footage (including proposed project): Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives Compressed Gases 6. Oxidizers 10. Cryogenics Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials Flammable Solids 8. Unstable Reactives 12. Radioactives Call (858) 505-6700 prior to the issuance of a building permit. Corrosives Other Health Hazards None of These. me answer to any Diego, CA 92123. FEES ARE REQUIRED Project Completion Date: Expected Date of Occupancy: YES NO (for new construction or remodeling projects) 0 LJ', Is your business listed on the reverse side of this form? (check all that apply). 0 LM Will your business dispose of Hazardous Substances or Medical Waste in any amount? 0 I' Will your business store or handle Hazardous Substances in quantities greater than or equal to 55 gallons, 500 pounds and/or 200 cubic feet? 0 ElY' Will your business store or handle carcinogens/reproductive toxins in any quantity? 0 ijY Will your business use an existing or install an underground storage tank? 0 F WWI Will your business store or handle Regulated Substances (CalARP)? 0 ll your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? 0 ll your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to or greater than 1,320 gallons? (California's Aboveground Petroleum Storage Act). CalARP Exempt Data Initials CalARP Required Date Initials CalARP Complete Date Initials PART III: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT (APCD): Any YES* answer requires a stamp from APCD 10124 Old Grove Road, San Diego, CA 92131 aocdcomo&sdcounty.ca.pov (858) 586-2650). [*No stamp required if Q1 Yes and Q3 Yes and Q4-Q6 No]. The following questions are intended to identify the majority of air pollution issues at the planning stage. Projects may require additional measures not identified by these questions. For comprehensive requirements contact APCD. Residences are typically exempt, except - those with more than one building on the property; single buildings with more than four dwelling units; townhomes; condos; mixed-commercial use; deliberate bums; residences forming part of a larger project. rExcludes garages & small outbuildings.] YES NO 0 Will the project disturb 160 square feet or more of existing building materials? 0 Will any load supporting structural members be removed? Notification may be required 10 working days prior to commencing demolition. 0 IJ (ANSWER ONLY IF QUESTION I or 2 IS YES) Has an asbestos survey been performed by a Certified Asbestos Consultant or Site Surveillance , Technician? 0 II?J (ANSWER ONLY IF QUESTION 3 IS YES) Based on the survey results, will the project disturb any asbestos containing material? Notification ,- may be required 10 working days prior to commencing asbestos removal. 0 L!J W(ANSWER W111 the projector associated construction equipment emit air contaminants? Seethe reverse side of this form or APCD factsheet (www.sdapcd.org/info/facts/oermits.pdf) for typical equipment requiring an APCD permit. 0 ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located within 1,000 feet of a school Briefly describe business activities: Briefly describe proposed project: I declare under penalty of perjury that to the best of my knowledge and belief ttie responses made herein are true and correct. Name of Owner or Authorized Agent Signature of Owner or Authorized Agent Date FOR OFFICAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION:____________________________________________________________________ BY: DATE: I / EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTYHMD* APCD COUNTY-HMD APCD COUNTY-HMD APCD A stamp in mis box oniv exempts businesses from completing or updating a Hazardous Materials Business Plan. Other permitting requirements may still apply. HM-9171 (08/15) County of San Diego - DEH - Hazardous Materials Division UXIM INDUSTRIAL WASTEWATER DISCHARGE PERMIT WAREWAUR SCREENING SURVEY Date Business Name 'W? Street Address J I t2V /CZS z2r Email Address PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT: (ON REVERSE SIDE CHECK TYPE OF BUSINESS) Check all below that are present at your facility: Acid Cleaning Ink Manufacturing Nutritional Supplement! Assembly Laboratory Vitamin Manufacturing Automotive Repair Machining I Milling Painting I Finishing Battery Manufacturing Manufacturing Paint Manufacturing Biofuel Manufacturing Membrane Manufacturing Personal Care Products Biotech Laboratory (i.e. water filter membranes) Manufacturing Bulk Chemical Storage Metal Casting / Forming Pesticide Manufacturing / Car Wash Metal Fabrication Packaging Chemical Manufacturing Metal Finishing Pharmaceutical Manufacturing Chemical Purification Electroplating (including precursors) Dry Cleaning Electroless plating Porcelain Enameling Electrical Component Anodizing Power Generation Manufacturing Coating (i.e. phosphating) Print Shop Fertilizer Manufacturing Chemical Etching / Milling Research and Development Film /X-ray Processing Printed Circuit Board Rubber Manufacturing Food Processing Manufacturing Semiconductor Manufacturing Glass Manufacturing Metal Powders Forming Soap! Detergent Manufacturing Industrial Laundry Waste Treatment! Storage SIC Code(s) (if known): Brief description of business activities (Production! Manufacturing Operations):______________ Description of operations generating wastewater (discharged to sewer, hauled or evaporated): Estimated volume of industrial wastewater to be discharged (gal /day): List hazardous wastes generated (type! volume): Date operation began/or will begin at this location: Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authority? Yes No If yes, when: Site Contact Title_______________________________ Signature Phone No.____________________________ ENCINA WASTEWATER AUTHORITY, 6200 Avenida Encinas Carlsbad, CA 92011 (760) 438-3941 FAX: (760) 476-9852