Loading...
HomeMy WebLinkAbout2330 SPRUCE ST; ; CB071655; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 10-10-2007 Residential Permit Permit No: CB071655 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 2330 SPRUCE ST CBAD RESDNTL Sub Type: RAD 1560510100 Lot #: 0. $134,403.00 Construction Type: NEW Reference #: 0 Structure Type: 0 Bathrooms: 0 CONBOY: 1026SF NEW (FAM. RM 2 BDRM, 1 BATH)150 SF KIT.REMODEL Status: ISSUED Applied: 06/18/2007 Entered By: JMA Plan Approved: 10/10/2007 Issued: 10/10/2007 Inspect Area: Orig PC#: Plan Check#: Applicant: Owner: CONBOY STEPHEN&CHERYL CONBOY STEPHEN&CHERYL 2330 SPRUCE ST 2330 SPRUCE ST CARLSBAD CA 92008 CARLSBAD CA 92008 Building Permit $654.36 Meter Size Add'l Building Permit Fee $0.00 Add'l Red. Water Con. Fee $0.00 Plan Check $425.33 Meter Fee . $0.00 Add'l Plan Check Fee $0.00 SDCWA Fee $0.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $13.44 PFF (3105540) $0.00 Park in Lieu Fee $0.00 PFF (4305540) $0.00 Park Fee $0.00 License Tax (3104193) $0.00 LFM Fee $0.00 License Tax (4304193) $0.00 Bridge Fee $0.00 Traffic Impact Fee (3105541) $0.00 Other Bridge Fee $0.00 Traffic Impact Fee (4305541) $0.00 BTD #2 Fee $0.00 Sidewalk Fee $0.00 BID #3 Fee $0.00 PLUMBING TOTAL $83.00 Renewal Fee $0.00 ELECTRICAL TOTAL $45.00 Add'l Renewal Fee $0.00 MECHANICAL TOTAL $70.00 Other Building Fee . $0.00 Housing Impact Fee $0.00 HMP Fee . $0.00 Housing lnLieu Fee $0.00 Pot. Water Con. Fee $0.00 Housing Credit Fee $0.00 Meter Size . Master Drainage Fee $0.00 Add'l Pot. Water Con. Fee $0.00 Sewer Fee $0.00 Red. Water Con. Fee $0.00 Additional Fees $0.00 TOTAL PERMIT FEES $1,291.13 Total Fees: $1,291.13 Total Payments To Date:EXPIRFr" C_R iff so.00 G PERMIT HAS EXPIRED IN ACCORDANCE WITH C.B.C. BU It SECTION 106.4.4 AS A!ENOED BY .M.C.16.04.03 DATt SITULD .w''- FINAL APPROVAL Inspector: XX Date: Clearance: NOTICE: Please take NOTICE that approval of your project includes the'Imposition* of fees, dedications, reservations, or other exactions hereafter collectively referred to as fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any City of Carlsbad '•,. 1635 Faraday Ave., Carlsbad, CA 92008 ,.T.... - 760-602-2717/2718/2719 Fax: 760-602-8558 W. Building Permit Application - eck Value Plan Ck. Deposit Date.. JOB ADDRESS _rStnTE#/SPACEU/UNiT#. APH •. - — . — CT/PROJECT 0 LOT U J PHASE U U OF UNITS U BEDROOMS U BATHROOMS . TENANT BUSINESS NAME TYPE OF cONST. 0CC. GROUP . DESCRIPTION OF WORK: (Please describe present use and proposed use) . .. . . . . - a / ,AL____ BUILDING AREA (SF) ADDITION AREA (SF) GARAGE (SF) PATIOS(SF) DECKS (SF) FIREP CE . AIR CONDIJJONING / FIRE SPRINKLERS YES D #_ NOD. YES NOD . YES 0 NOD DOMINION CONTACT NAME (If Different F Applies t) APPLICANT NAME ADDRESS ADDRESS . . :. 33°. CITY U STAJ4 ZIP CITY . STATE . . ZIP PHONE . . . . FAX . 7,0 .-73o_3si PHONE EMAIL S(!w1L,01, SC6/i >J: . EMAIL PROPERTY OWNER NAME. ..' . . . . C CONTRACTOR BUS. NAME . ..,'.' . . . Di c&ji e;cA. ADDRESS .. . . f . . . . .. . ADDRESS Sj7/V c'ce CITY ,. . . STATE . . ZIP . CITY .. . .:' STATE . . ZIP PHONE . FAX . 7_73_3',s/ PHONE' . .. FAX EMAIL EMAIL ' ARCH/DESIGNER NAME & ADDRESS - . STATELIC. U STATE L1C# CLASS CITY BUS. LiC.# Lwc. Iul., ouniness ann rroieanioos 'one: uny usy or bounty worco requires a permit o costruce. alter improve emoiisn or ropair,auy structure prior to la issuance. a159 requires the applicant for 10th permit to bile a signed statement that e is kconsed puraoant, to the provisions of' the Contractor's License aw {Oiapte 9, commending with Section 1000' of Divuioo .3 of the Business and Profesnioiia (ode) or that he is exempt there in. and the basis for the alleged exemption. Any violation of Section 1031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). Workers' Compensation Declaration:! hereby aftImn under penalty of perjury one of the following declarations: . . . . . . . . I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co. . . -. Policy No. . Expiration Dale This section need not be completed if the permit is for one hundred ddllars ($100) or less: .. . . . . . 0 Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal pinalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. . CONTRACTOR SIGNATURE . . . . . . DATE . . : .1 hçby affirm that lam exempt from Contractor's License Law for the following reason: . as owner of the property or my employees with wages as their sole compensalion, will do the work and the structure is not intended or offered for sate (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sate. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the bUrden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project(Sec. 7044, Business and Professions Code: The Contractor's License law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). - I am exempt under Section . Business and Professions Code for this reason: i:i perèonally plan to provide the major labor and materials for construction of the proposed properly improvement. C3 Yes 0 No . I (have! have not) signed an application for a building permit for the proposed work. . . . I have contracted with the following person (firm) to provide the proposed construction (include name address! phone/contractors' license number):. 4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/address! phone contractors' license number): 5.1 will provide some of the work, bull have ~ired)ng personsto provide the w'rk indicaled (include name/address/phone!type ofwork): ..'PROPERTY OWNER SIGNATURE .' ' DATE MD c)17 4I Is the applicant or future building occupant required to submit a business plan, acutely hdous materialsregistration form or risk management and prevention program,under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 Yes 0 No Is the applicant or future building occupant required to obtain a permit from the air pollulion control district or air quality management district? 0 Yes 0 No Is the facility lobe constructed within 1,000 feet of the outer boundary of a school site? DYes 0 No . . IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE 0 FFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there IS a construction lending agency for the performance of the work this permit is issued (Sec 3097 (I) Civil Code) Lender's Name ' . . Lender's Address I certify that I have read the application and state that the above information is correct and that the information onihe plans is accurate.' lagree to comply with all City ordinances and State laws relating to building construction.' I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF-THE GRANTING OF THIS PERMIT. OSHA:-An OSHA permit is required for excavations over 50' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work aulhorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the wOrk is commenced fora period of 180 days (Section 106.4:4 Uniform Building Code): 'APPLICANT'S SIGNATURE . . .. - . , DATE . . . . . O+T. 4L City of Carlsbad :rni r i. .I.. .0 February 23, 2009 Permit Number: CB07 1655 Issue Date: 10/10/2007 CONBOY STEPHEN&CI-IERYL • 2330 SPRUCE ST CARLSBAD CA 92008 RE: BUILDING PERMIT EXPIRATION ADDRESS: 2330 SPRUCE ST PLEASE CALL FOR AN INSPECTION IF WORK IS COMPLETE Our records indicate that your building permit will expire by limitation of time on 03/25/2009. The provisions of UBC, Section 106.4.4 as amended by the Carlsbad Municipal Code state: "EXPIRATION. Every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is stopped at any time after the work is commenced for a period of 180 days or if the building or work authorized by such permit exceeds three calendar years from the issuance date of permit. Work shall be presumed to have commenced if the permittee has obtained a required inspection approval of work authorized by the permit by the Building Official within 180 days of the date of permit issuance. Work shall be presumed to be stopped if the permittee has not obtained a required inspection approval of work by the Building Official within each 180 day period upon the initial commencement of work authorized by such permit. Before such work can be recommenced, a new permit shall be obtained to do so, and the fee, therefore, shall be one-half the amount required for a new permit for such work, and provided that no changes have been made or will be made in the original plans and specifications for such Work, and provided further that such suspension or abandonment has not exceeded one year. In order to renew action on a permit after expiration, the permittee shall pay a new permit fee. Any person holding an unexpired permit may apply for an extension of the time within which work may commence under that permit when the permittee is unable to commence work within the time period required by this section for good and satisfactory reasons. The Building Official may extend the time for action by the permittee for a period not exceeding 180 days on written request by the permittee showing that circumstances beyond the control of the permittee have prevented action from being taken. No permit shall be extended more than once. Please check below indicating your intentions and return this letter to us. Project abandoned. A new permit will be obtained prior to commencing work. No fee extension requested for 180 days. (attach a letter of explanation) Renewal permit requested. If the project has been completed and only a final inspection is needed, please call the inspection request line at (760) 602-2725. If you have any questions, please contact the Building Inspection Department at (760) 602-2700. Christine Wauschek Office Specialist 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-2700 • FAX (760) 602-8560 CitV of Crlsbad I:Buiud!g Depart nt May 29, 2008 Permit Number: CB07 1655 Issue Date: 10/10/2007 STEPHEN & CHERYL CONBOY 2330 SPRUCE ST CARLSBAD CA 92008 RE: BUILDING PERMIT EXPIRATION ADDRESS: 2330 SPRUCE ST PERMIT TYPE: RESDNTL PLEASE CALL FOR AN INSPECTION IF WORK IS COMPLETE Our records indicate that your building permit will expire by limitation of time on 06/08/2008. The provisions of UBC, Section 106.4.4 as amended by the Carlsbad Municipal Code state: "EXPIRATION. Every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit (unless issued prior to 7/1/99 which is one year from date of permit), or if the building or work authorized by such permit is stopped at any time after the work is commenced for a period of 180 days or if the building or work authorized by such permit exceeds three calendar years from the issuance date of permit. Work shall be presumed to have commenced if the permittee has obtained a required inspection approval of work authorized by the permit by the Building Official within 180 days of the date of permit issuance. Work shall be presumed to be stopped if the permittee has not obtained a required inspection approval of work by the Building Official within each 180 day period upon the initial commencement of work authorized by such permit. Before such work can be recommenced, a new permit shall be obtained to do so, and the fee, therefore, shall be one-half the amount required for a new permit for such work, and provided that no changes have been made or will be made in the original plans and specifications for such work, and provided further that such.suspension or abandonment has not exceeded one year. In order to renew action on a permit after expiration, the permittee shall pay a new permit fee. Any person holding an unexpired permit may apply for an extension of the time within which work may commence under that permit when the permittee is unable to commence work within the time period required by this section for good and satisfactory reasons. The Building Official may extend the time for action by the permittee for a period not exceeding 180 days on written request by the permittee showing that circumstances beyond the control of the permittee have prevented action from being taken. No permit shall be extended more than once. Please check below indicating your intentions and return this letter to us. Project abandoned. A new permit will be obtained prior to commencing work. No fee extension requested for 180 days. (attach a letter of explanation) Renewal permit requested. If the project has been completed and only a final inspection is needed, please call the inspection request line at (760) 602-2725. If you have any questions, please contact the Building Inspection Department at (760) 602-2700. Christine Wauschek Office Specialist kX 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-2700 9 FAX (760) 602-8560® ,71A City of Carlsbad Bldg Inspection Request 4wu For: 06/22/2009 Permit# CB071655 Title: CONBOY: 1026SF NEW (FAM. RM, Description: 2 BDRM, I 1BATH)150 SF KIT.REMODEL Type: RESDNTL Sub Type: RAD Job Address: 2330 SPRUCE ST Suite: Lot 0 Location: APPLICANT CONBOY STEPHEN&CHERYL Owner: CONBOY STEPHEN&CHERYL Remarks: permit status check Total Time: Inspector Assignment: PY Phone: Inspector: Requested By: CHRISTINE Entered By: CHRISTINE CD Description 92 Compliance Investigation Act Comments CC4& Jo WtJ Comments/Notices/Holds J Notice RELATES TO CODE ENFORCEMENT CASE CV070178- DO NOT EXTEND PERMIT Associated PCRs/CVs Original PC# CV061200 CLOSED H- ALLEGED ILL CONST; CV070178 CLOSED H- ALLEGED ILL CONST; PCR071I3 WITHDRAW CONBOY: CHANGE TO ROOF W/l FT.; WALL POP-OUT IN MASTER Inspection History Act lnsp Comments CO PC SEE CARD BACK FOR CORR. CO PC TOP. OUT OK NAIL PLATES REQD AP PC AP P.9 PARRY 1ST FLOOR @ REAR AND ENTRY OK TO INSULATE Date Description 09/26/2008 14 Frame/Steel/Bolting/Welding 09/26/2008 24 Rough/Topout 09/26/2008 34 Rough Electric 09/26/2008 44 Rough/Ducts/Dampers —12/11/2007 14 Frame/Steel/Bolting/Welding 12/11/2007 34 Rough Electric 11/15/2007 83 Roof Sheathing/Ext Shear 11/14/2007 13 Shear Panels/HD's 11/14/2007 15 Roof/Reroof 10/30/2007 15 Roof/Reroof 10/30/2007 15 Roof/Reroof 10/30/2007 18 Exterior Lath/Drywall 10/23/2007 14 Frame/Steel/Bolting/Welding 10/23/2007 15 Roof/Reroof 10/18/2007 14 Frame/Steel/Bolting/Welding 10/15/2007. 11 Ftg/Foundation/Piers 10/11/2007 11 Ftg/Foundation/Piers PA PY AP PY NS PY OUT OFTIME NS PY CO PY revise roof plan CO PY PA PY FIREPLACE PA PY DECK JOIST NR PY PA PY SUB FLOOR @ FRONT NEED UNDER FLOOR VENT AND ACCESS PA PY FTG & SLAB © BACK OF GARAGE AND FTG AT EAST SIDE PA PY EsGil Corporation 1 In (Partners Flip with çovernment for Bui(iing Safety DATE: October 8, 2007 O A PLICANT / JURISDICTION: City of Carlsbad OPCA REVIEWER. U FILE PLAN CHECK NO.: 07-1655 . SET: VIII PROJECT ADDRESS: 2330 Spruce St. PROJECT NAME: Conboy Residence/SFD Addition and Remodel LII The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified in the attached list are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. LI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. fl The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. I Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: . Mail Telephone Fax In Person REMARKS: By: Sergio Azuela Enclosures: Esgil Corporation 0 GA 0 MB 0 EJ 0 PC 10/01 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax(858)560-1576 Ôityof Carlsbad 07-1655 &ctober 8, 2007 Show on plans that openings between railings shall be less than 4". The triangular openings formed by the riser, tread and bottom element of a guardrail at a stair shall be less than 6". Show a self-closing door, EITHER 1-3/8" SOLID CORE OR A LISTED 20 MINUTE ASSEMBLY, for the door between the Garage and breezeway. Show on plans that the floor or landing in the garage is not more than one inch lower than the door threshold for the door between the Garage and breezeway on the North Side of the Garage. . All sheets of plans must be signed by the person responsible for their preparation. ESGII Corporation In Partners flip witfi government for Bui(iing Safety DATE: October 1, 2007 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 07-1655 SET: VII PROJECT ADDRESS: 2330 Spruce St. APPLICANT U PLAN REVIEWER U FILE PROJECT NAME: Conboy Residence/SFD Addition and Remodel II The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. LI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. LII The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. - LII The applicant's copy of the-check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Steve Conboy 2330 Spruce St., Carlsbad, CA 92008 LI Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Pteve Conboy Date contacte'?/1f0 '7 (by1I4 Mail /Telephone Fax /in Person Telephone #: (760) 730-3951 Fax #: (760) 720-9886 REMARKS: APPLICANT DID NOT PROVIDE PLANS FOR THIS RECHECK. ONLY SOME RESPONSES TO THE REMAINING CORRECTIONS WERE PROVIDED. ( By: Sergio Azuela Enclosures: Esgil Corporation [3, GA D MB 0 EJ 0 Pc 09/24 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad 07-1655 October 1, 2007 RECHECK PLAN CORRECTION LIST JURISDICTION: City of Carlsbad PROJECT ADDRESS: 2330 Spruce St. DATE PLAN RECEIVED BY ESGIL CORPORATION: 09/24 REVIEWED BY: Sergio Azuela FOREWORD (PLEASE READ): PLAN CHECK NO.: 07-1655 SET: VII DATE RECHECK COMPLETED: October 1, 2007 This plan review is limited to.the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? ]Yes UNo City* of Carlsbad 07-1655 October 1, 2007 1. Please make all corrections, as requested in the correction list. Submit three new complete sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. APPLICANT DID NOT PROVIDE PLANS FOR THIS RECHECK. 17. Guardrails (Section 509.1): d) Openings between railings shall be less than 4". The triangular openings formed by the riser, tread and bottom element of a guardrail at a stair shall be less than 6". THE STRUCTURAL ENGINEER RESPONDED FOR ITEM C, OF THIS CORRECTION. ITEM C OF THIS CORRECTION WAS RESOLVED. HOWEVER THE SPACING FOR RAILINGS HAS NOT BEEN SHOWN ON PLANS. THEREFORE ITEM d OF THIS CORRECTION IS STILL APPLICABLE. PROVIDE THE COMPLETE GUARDRAIL DETAILS AND CROSS-REFERENCE FROM DETAILS TO ALL APPLICABLE LOCATIONS ON THE FLOOR PLANS. ADDITIONAL CORRECTIONS MAY FOLLOW. Show a self-closing door, EITHER 1-318" SOLID CORE OR A LISTED 20 MINUTE ASSEMBLY, for openings between garage and dwelling. Section 302.4. a) Please show it on plans for the door between the Garage and breezeway on the North Side of the Garage. THE REQUIRED INFORMATION (EITHER 1-3/8" SOLID CORE OR A LISTED 20 MINUTE ASSEMBLY) IS MISSING AT THE DOOR BETWEEN THE GARAGE AND THE BREEZEWAY. ORIGINAL CORRECTION IS STILL APPLICABLE. PLEASE SEE THE ATTACHED SHEET. Doors may open into the garage only if the floor or landing in the garage is not more than one inch lower than the door threshold. Section 1003.3.1.6. a) Please show it on plans for the door between the Garage and breezeway on the North Side of the Garage. THE REQUIRED INFORMATION IS MISSING AT THE DOOR BETWEEN THE GARAGE AND THE BREEZEWAY. ORIGINAL CORRECTION IS STILL APPLICABLE. PLEASE SEE THE ATTACHED SHEET. City of Carlsbad 07-1655 October 1, 2007 FROM THE ADDITIONAL SCOPE OF WORK (PCR07-113) THE FOLLOWING CORRECTIONS ARE STILL APPLICABLE: Verify that the final sets of plans and any new calculations will be stamped and signed by engineer of record also. The plans need to address only scope of work and all other portions to be noted as existing or removed form plans. For example provide a foundation plan which does appear to be applicable to this scope of work and do not see how sheet SI-2 as no floor/deck framing shown . No written response was provided for this correction. Original correction is still applicable. Do not see where floor/deck framing addressed pop out with weight of new walls and roof framing. Is this setting between the deck joists, on double up joist, blocking below window wall etc. No written response was provided for this correction. Original correction is still applicable. If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. Thank you. + 42 CC W/ 2x4 L r vpp C#71, 14U UPdNUIiUL.) tir& 1JIJ 1iU¼JVL ULML!J. 17g" (N)3 F CLOSING c__._/ (E)2668 SELF - (E)5/80 TYPE X DRYWALL LANDING 1" BELOW 7 (SECTION 302.4.) (E) boo RAGE GRADE CONCRETE STEPS TO if SECTION 1003.3.1.6. ?-E ISTING GARAGE 3'-ll" V E)2668 C 20 MIN. ASSEMBLY 1-3/8 SOLID CORE STORAGE (E)24 CLEARANCE SECTION 2904 !bôc' cc/ 17 c Ctl€V w-Z To 5 (N) POST (N)SHORT WALL 36 HIGH N)EN TRY a,-or Ct.G. EsGil Corporation In PartnersIiip witfi government for Buifding Safety DATE: September 21, 2007 0 APPLICANT JURISDICTION: City of Carlsbad 0 PLAN REVIEWER 0 FILE PLAN CHECK NO.: 07-1655 SET: VI PROJECT ADDRESS: 2330 Spruce St. PROJECT NAME: Conboy Residence/SFD Addition and Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. LI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Steve Conboy 2330 Spruce St., Carlsbad, CA 92008 EIIJ Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: SSeve Conboy Date contacted: 1/~ 1/O1 (by4) Mail /'Telephone Fax /In Person Telephone #: (760) 730-3951 Fax #: (760) 720-9886 REMARKS: APPLICANT DID NOT PROVIDE PLANS FOR THIS RECHECK. ONLY SOME RESPONSES TO THE REMAINING CORRECTIONS WERE PROVIDED. By: Sergio Azuela Enclosures: Esgil Corporation 0 GA 0 MB 0 EJ 0 Pc 09/14 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad 07-1655 September 21, 2007 RECHECK PLAN CORRECTION LIST JURISDICTION: City of Carlsbad PROJECT ADDRESS: 2330 Spruce St. DATE PLAN RECEIVED BY ESGIL CORPORATION: 09/14 REVIEWED BY: Sergio Azuela FOREWORD (PLEASE READ): PLAN CHECK NO.: 07-1655 SET: VI DATE RECHECK COMPLETED: September 21, 2007 This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? DYes ONo City of Carlsbad 07-1655 September 21, 2007 1. Please make all corrections, as requested in the correction list. Submit three new complete sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. . APPLICANT DID NOT PROVIDE PLANS FOR THIS RECHECK. 17. Guardrails (Section 509.1): a) Shall be installed at open sides of landings. PLEASE SHOW IT AT THE SPIRAL STAIRWAY LANDING. This information is required, please include the required dimensions on the plans. d) Openings between railings shall be less than 4". The triangular openings formed by the riser, tread and bottom element of a guardrail at a stair shall be less than 6". THE STRUCTURAL ENGINEER RESPONDED FOR ITEM C, OF THIS CORRECTION. ITEM C OF THIS CORRECTION WAS RESOLVED. HOWEVER THE SPACING FOR RAILINGS HAS NOT BEEN SHOWN ON PLANS. THEREFORE ITEM d OF THIS CORRECTION IS STILL APPLICABLE. PROVIDE THE COMPLETE GUARDRAIL DETAILS AND CROSS-REFERENCE FROM DETAILS TO ALL APPLICABLE LOCATIONS ON THE FLOOR PLANS. ADDITIONAL CORRECTIONS MAY FOLLOW. Handrails (Section 1003.3.3.6): a) Handrails and extensions shall be 34" to 38" above nosing of treads and be continuous. PLEASE REVISE THE PLANS TO INCLUDE THE SPECIFICATION THAT READS "HANDRAILS ARE 36" ABOVE THE TREADS NOSING" Provide spiral stairway details, per Section 1003.3.3.8.3: a) Minimum run is 7-1/2 inches MEASURED AT A POINT 12 INCHES FROM WHERE THE TREADS ARE THE NARROWEST. NOT SHOWN ON PLANS. c) Minimum headroom is 6 feet 6 inches. NOT SHOWN ON PLANS FOR THE SPIRAL STAIRWAY. 0 SEE NEXT PAGE FOR ADDITIONAL REMAINING CORRECTIONS. City of Carlsbad 07-1655 September 21, 2007 21. Provide I.C.B.O. Research Report and number for metal stairway, or submit plans and calculations AND APPROVED FABRICATOR REGISTERED WITH THE BUILDING DEPARTMENT or note that the stairway fabrication plans shall be submitted to and approved by the building official prior to installation. PLEASE SHOW ON PLANS ALL ELEMENTS INCLUDED IN THE CALCULATIONS AS: TYPICAL RAIL POST. AB's @BASE PLATE, STAIR TREADS (MCI2XI0.6), ETC. PLEASE CALL THE PLANS EXAMINER TO CLARIFY THIS CORRECTION. Show a self-closing door, EITHER 1-3/8" SOLID CORE OR A LISTED 20 MINUTE ASSEMBLY, for openings between garage and dwelling. Section 302.4. a) Please show it on plans for the door between the Garage and breezeway on the North Side of the Garage. THE REQUIRED INFORMATION (EITHER 1-3/8" SOLID CORE OR A LISTED 20 MINUTE ASSEMBLY) IS MISSING AT THE DOOR BETWEEN THE GARAGE AND THE BREEZEWAY. ORIGINAL • CORRECTION IS STILL APPLICABLE. Doors may open into the garage only if the floor or landing in the garage is not more than one inch lower than the door threshold. Section 1003.3.1.6. a) Please show it on plans for the door between the Garage and breezeway on the North Side of the Garage. THE REQUIRED INFORMATION IS MISSING AT THE DOOR BETWEEN THE GARAGE AND THE BREEZEWAY. ORIGINAL CORRECTION IS STILL APPLICABLE. FROM THE SOILS REPORT PROVIDED THE FOLLOWING CORRECTIONS ARE APPLICABLE: Specify the slab on grade, including the reinforcement and the underlayment. Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (required by the soil report - page 16). Include the "Soils Compliance Prior to Foundation Inspection" item in the "Special Inspection Program' form provided on sheet SCS. FROM THE ADDITIONAL SCOPE OF WORK (PCR07-113) THE FOLLOWING CORRECTIONS ARE STILL APPLICABLE: Verify that the final sets of plans and any new calculations will be stamped and signed by engineer of record also. The plans need to address only scope of work and all other portions to be noted as existing or removed form plans. For example provide a foundation plan which does appear to be applicable to this scope of work and do not see how sheet SI-2 as no floor/deck framing shown . No written response was provided for this correction. Original correction is still applicable. City Qf Carlsbad 07-1655 September 21, 2007 . SEE NEXT PAGE FOR ADDITIONAL REMAINING CORRECTIONS. 2. Do not see where floor/deck framing addressed pop out with weight of new walls and roof framing. Is this setting between the deck joists, on double up joist, blocking below window wall etc. No written response was provided for this correction. Original correction is still applicable. If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. Thank you. EsGil Corporation In tFartnersUp with goveniment for Bui(€fing Safety DATE: September 14, 2007 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 07-1655 SET:V PROJECT ADDRESS: 2330 Spruce St. L3 AeeLVANT JURIS. O PLAN REVIEWER 0 FILE PROJECT NAME: Conboy Residence/SFD Addition and Remodel LI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. El The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. El The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. El The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Steve Conboy 2330 Spruce St., Carlsbad, CA 92008 El Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Steve Conboy Telephone #: (760) 730-3951 Date contacted:/,do7 (by: 1 )c) Fax #: (760) 720-9886 Mail— Telephone Fax— In Person REMARKS: APPLICANT DID NOT PROVIDE COMPLETE SETS OF PLANS FOR THIS RECHECK. By: Sergio Azuela Enclosures: Esgil Corporation 0 GA 0 MB 0 EJ 0 PC 09/11 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad 07-1655 September 14, 2007 RECHECK PLAN CORRECTION LIST JURISDICTION: City of Carlsbad PROJECT ADDRESS: 2330 Spruce St. DATE PLAN RECEIVED BY ESGIL CORPORATION: 09/11 REVIEWED BY: Sergio Azuela PLAN CHECK NO.: 07-1655 SET: V DATE RECHECK COMPLETED: September 14, 2007 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? DYes DNa City of Carlsbad 07.1655 September 14, 2007 1. Please make all corrections, as requested in the correction list. Submit three new complete sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. APPLICANT DID NOT PROVIDE COMPLETE SETS OF PLANS FOR THIS RECHECK. 17. Guardrails (Section 509.1): a) Shall be installed at open sides of landings. PLEASE SHOW IT AT THE SPIRAL STAIRWAY LANDING. d) Openings. between railings shall be less than 4". The triangular openings formed by the riser, tread and bottom element of a guardrail at a stair shall be less than 6". THE STRUCTURAL ENGINEER RESPONDED FOR ITEM C, OF THIS CORRECTION. ITEM C OF THIS CORRECTION WAS RESOLVED. HOWEVER THE SPACING FOR RAILINGS HAS NOT BEEN SHOWN ON PLANS. THEREFORE ITEM d OF THIS CORRECTION IS STILL APPLICABLE. PROVIDE THE COMPLETE GUARDRAIL DETAILS AND CROSS-REFERENCE FROM DETAILS TO ALL APPLICABLE LOCATIONS ON THE FLOOR PLANS. ADDITIONAL CORRECTIONS MAY FOLLOW. Handrails (Section 1003.3.3.6): a) Handrails and extensions shall be 34" to 38" above nosing of treads and be continuous. PLEASE REVISE THE PLANS TO INCLUDE THE SPECIFICATION THAT READS "HANDRAILS ARE 36" ABOVE THE TREADS NOSING" Provide spiral stairway details, per Section 1003.3.3.8.3: a) Minimum run is 7-1/2 inches measured at a point 12 inches from where the treads are the narrowest. NOT SHOWN ON PLANS. c) Minimum headroom is 6 feet 6 inches. NOT SHOWN ON PLANS. 0 0 SEE NEXT PAGE FOR ADDITIONAL REMAINING CORRECTIONS. City of Carlsbad 07-1655 September 14, 2007 21. Provide I.C.B.O. Research Report and number for metal stairway, or submit plans and calculations AND APPROVED FABRICATOR REGISTERED WITH THE BUILDING DEPARTMENT or note that the stairway fabrication plans shall be submitted to and approved by the building official prior to installation. PLEASE SHOW ON PLANS ALL ELEMENTS INCLUDED IN THE *CALCULATIONS AS: TYPICAL RAIL POST. AB's @BASE PLATE, STAIR TREADS (MCI 2XIO.6), ETC. Show a self-closing door, EITHER 1-3/8" SOLID CORE OR A LISTED 20 MINUTE ASSEMBLY, for openings between garage and dwelling. Section 302.4. a) Please show it on plans for the door between the Garage and breezeway on the North Side of the Garage. THE REQUIRED INFORMATION WAS NOT PROVIDED. ORIGINAL CORRECTION IS STILL APPLICABLE. Doors may open into the garage only if the floor or landing in the garage is not more than one inch lower than the door threshold. Section 1003.3.1.6. a) Please show it on plans for the door between the Garage and breezeway on the North Side of the Garage. THE REQUIRED INFORMATION WAS NOT PROVIDED. ORIGINAL CORRECTION IS STILL APPLICABLE. FROM THE SOILS REPORT PROVIDED THE FOLLOWING CORRECTIONS ARE APPLICABLE: Specify the slab on grade, including the reinforcement and the underlayment. Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (required by the soil report - page 16). Include the "Soils Compliance Prior to Foundation Inspection" item in the "Special Inspection Program" form provided on sheet SCS. FROM THE ADDITIONAL SCOPE OF WORK (PCR07-113) THE FOLLOWING CORRECTIONS ARE STILL APPLICABLE: Verify that the final sets of plans and any new calculations will be stamped and signed by engineer of record also. The plans need to address only scope of work and all other portions to be noted as existing or removed form plans. For example provide a foundation plan which does appear to be applicable to this scope of work and do not see how sheet SI-2 as no floor/deck framing shown . No written response was provided for this correction. Original correction is still applicable. 0 SEE NEXT PAGE FOR ADDITIONAL REMAINING CORRECTIONS. i ". City of Carlsbad 07-1655 September 14, 2007 2. Do not see where floor/deck framing addressed pop out with weight of new walls and roof framing. Is this setting between the deck joists, on double up joist, blocking below window wall etc. No written response was provided for this correction. Original correction is still applicable. If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. Thank you. EsGil Corporation In (Partners Up with government for qiui(iing Safety DATE: August 29, 2007 U APPLICANT L3 i JURISDICTION: City of Carlsbad U PLAN REVIEWER U FILE PLAN CHECK NO.: 07-1655 SET: IV PROJECT ADDRESS: 2330 Spruce St. PROJECT NAME: Conboy Residence/SFD Addition and Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. Lii The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Steve Conboy 2330 Spruce St., Carlsbad, CA 92008 LI Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Stejie Conboy Date contacted: O'7(byi/.rlj) Mail /Telephone Fax Vin Person LII REMARKS: By: Sergio Azuela Esgil Corporation EGA LIMB DEJ [:1 PC Telephone #: (760) 730-3951 Fax #: (760) 720-9886 Enclosures: 08/23 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad 07-1655 August 29, 2007 RECHECK PLAN CORRECTION LIST JURISDICTION: City of Carlsbad PROJECT ADDRESS: 2330 Spruce St. DATE PLAN RECEIVED BY ESGIL CORPORATION: 08/23 REVIEWED BY: Sergio Azuela FOREWORD (PLEASE READ): PLAN CHECK NO.: 07-1655 SET: IV DATE RECHECK COMPLETED: August 29, 2007 This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? UYes UNo city df Carlsbad 07-1655 August 29, 2007 Please make all corrections, as requested in the correction list. Submit three new complete sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 9. Glazing in the following locations should be of safety glazing material in accordance with Section 2406.4 (see exceptions): a) Fixed and sliding panels of sliding door assemblies and panels in swinging doors other than wardrobe doors. PLEASE SHOW IT ON PLANS FOR ALL (N) FRENCH DOORS AND ALSO FOR THE (N) 16'X7'-0" SLIDERS, (N) 12'-0" X 6'-8" SLIDERS AND (N) 9068 SL @ FAMILY R. b) Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface. PLEASE SHOW IT ON PLANS FOR THE FOLLOWING WINDOWS: (N) 3040 ADJACENT TO THE (N) FRENCH DOOR (ADJACENT TO THE (N) FIREPLACE)AT THE FRONT OF THE (E) LIVING. 10. Sleeping rooms shall have a window or exterior door for emergency escape. Sill height shall not exceed 44" above the floor. Windows mu,st have an openable area of at least 5.7 square feet with the minimum openable width 20" and the minimum openable height 24". The emergency door or window shall be openable from the inside to provide a full, clear opening without the use of separate tools. Section 310.4. a) Clearly show on plans the type of all windows (casement, single hung, fixed, slider, etc.), and also show if they are (E) existing or (N) new. Additional corrections may follow. THE SH (SINGLE HUNG) WINDOWS WHICH ARE LESS THAN 5' HEIGHT WILL NOT COMPLY WITH THE MINIMUM OPENABLE HEIGHT OF 24" REQUIRED. AT BEDROOMS 3 AND 4. ORIGINAL CORRECTION IS STILL APPLICABLE. City of Carlsbad 07-1655 August 29, 2007 17. Guardrails (Section 509.1): Shall be installed at open sides of landings. Shall have a height of 36". d) Openings between railings shall be less than 4". The triangular openings formed by the riser, tread and bottom element of a guardrail at a stair shall be less than 6". PROVIDE THE COMPLETE GUARDRAIL DETAILS AND CROSS-REFERENCE FROM DETAILS TO ALL APPLICABLE LOCATIONS ON THE FLOOR PLANS. ADDITIONAL CORRECTIONS MAY FOLLOW. 19. Handrails (Section 1003.3.3.6): a) Handrails and extensions shall be 34" to 38" above nosing of treads and be continuous. PLEASE SHOW IT ON PLANS FOR ALL NEW STAIRS. 20. Provide spiral stairway details, per Section 1003.3.3.8.3: a) Minimum run is 7-1/2 inches measured at a point 12 inches from where the treads are the narrowest. NOT SHOWN ON PLANS. Minimum headroom is 6 feet 6 inches. NOT SHOWN ON PLANS. The tread must provide a clear walking area measuring at least 26 inches from the outer edge of the supporting column to the inner edge of the handrail. NOT SHOWN ON PLANS. 21. Provide I.C.B.O. Research Report and number for metal stairway, or submit plans and calculations AND APPROVED FABRICATOR REGISTERED WITH THE BUILDING DEPARTMENT or note that the stairway fabrication plans shall be submitted to and approved by the building official prior to installation. PLEASE SHOW ON PLANS ALL ELEMENTS INCLUDED IN THE CALCULATIONS AS: TYPICAL RAIL POST. AB's @BASE PLATE, STAIR TREADS (MCI 2XIO.6), ETC. Show a self-closing door, EITHER 1-3/8" SOLID CORE OR A LISTED 20 MINUTE ASSEMBLY, for openings between garage and dwelling. Section 302.4. a) Please show it on plans for the door between the Garage and breezeway on the North Side of the Garage. THE REQUIRED INFORMATION WAS NOT PROVIDED. ORIGINAL CORRECTION IS STILL APPLICABLE. Doors may open into the garage only if the floor or landing in the garage is not more than one inch lower than the door threshold. Section 1003.3.1.6. a) Please show it on plans for the door between the Garage and breezeway on the North Side of the Garage. THE REQUIRED INFORMATION WAS NOT PROVIDED. ORIGINAL CORRECTION IS STILL APPLICABLE. City of Carlsbad 07-1655 August 29, 2007 34. Provide a copy of the project soil report prepared by a California licensed architect or civil engineer. The report shall include foundation design recommendations based on the engineer's findings and shall comply with UBC Section 1804. a) According to the CARLSBAD SPECIAL CODE REQUIREMENTS: all new residential buildings, including additions, require a soils report. THE REQUIRED SOILS REPORT WAS NOT PROVIDED. ORIGINAL CORRECTION IS STILL APPLICABLE. FROM THE ADDITIONAL SCOPE OF WORK (PCR07-113) THE FOLLOWING CORRECTIONS ARE STILL APPLICABLE: Verify that the final sets of plans and any new calculations will be stamped and signed by engineer of record also. The plahs need to address only scope of work and all other portions to be noted as existing or removed form plans. For example provide a foundation plan which does appear to be applicable to this scope of work and do not see how sheet SI-2 as no floor/deck framing shown Do not see where floor/deck framing addressed pop out with weight of new walls and roof framing. Is this setting between the deck joists, on double up joist, blocking below window wall etc. No insulation provided i.e. R-19 at under floor, 13 in walls and R-30 in ceiling. The plans appear to be reduced in size. What is the area of Additional sq footage adding? If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. Thank you. ___ • EsGil Corporation In cPartnersliip with government for Bui(iing Safety DATE: August 13, 2007 132UCNT -UR1) JURISDICTION: Cit d 'D1'tiThEVIEWER FILE PLAN CHEC .: 07-1655 SET: III PROJECT AD S: 2330 Spruce St. 7'21 (a 7 PROJECT NAME: Conboy Residence/SFD Addition and Remodel The plans transmitted herewith have been corrected where necessary and substantially comply ng codes Iut'eQEomWQtt(codes when minor d ciencies identified below are resolved and checked by bUilding department staff. LI The r transmitted herewith have significant deficiencies identified on the enclosed check list cte d su or z r t I d n. The I being held at Esgil n un corrected D ans are su mitted for recheck. ie applicant's c'py of the check list is enclosed for the jurisdiction to forward to the applicant rsa4ce cia to: Steve Con boy 2330 Spruce St., Carlsbad, CA 92008 EN wom OcIroporatflon : Person contacted: StJ: atd. onboy Date contacted: (by24 Mail v4lephone Fax ,/In Person anchec b3nmpleted.* ciha b ted. #: (760) 730-3951 Fax #: (760) 720-9886 LII REMARKS: 3[o Azuela Enclosures: Esgil Corporation DGA 0MB 0 El PC [sI;IYk,I!] 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In Partnership witfi covernment for 73ui(ding Safety DATE: August 13, 2007 yAP.UCNT UR1. JURISDICTION: City of Carlsbad C:9 AN REVIEWER 0 FILE PLAN CHECK NO.: 07-1655 SET: III PROJECT ADDRESS: 2330 Spruce St. PROJECT NAME: Conboy Residence/SFD Addition and Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. LI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. LI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Steve Conboy 2330 Spruce St., Carlsbad, CA 92008 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Steve Conboy Date contacted: (by.I Mail V1Iephone Faxy/in Person LI REMARKS: By: Sergio Azuela Esgil Corporation [:1 GA 0MB OEJ DPC Telephone #: (760) 730-3951 Fax #: (760) 720-9886 Enclosures: 08/09 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax(858)560-1576 City of Carlsbad 07-1655 August 13, 2007 RECHECK PLAN CORRECTION LIST JURISDICTION: City of Carlsbad PROJECT ADDRESS: 2330 Spruce St. DATE PLAN RECEIVED BY ESGIL CORPORATION: 08/09 REVIEWED BY: SerEio Azuela PLAN CHECK NO.: 07-1655 SET: III DATE RECHECK COMPLETED: August 13, 2007 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please.briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? DYes UNo City of Carlsbad 07-1655 August 13, 2007 Please make all corrections, as requested in the correction list. Submit three new complete sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 9. Glazing in the following locations should be of safety glazing material in accordance with Section 2406.4 (see exceptions): a) Fixed and sliding panels of sliding door assemblies and panels in swinging doors other than wardrobe doors. Please show it on plans for all (N) French Doors and also for the (N) 16'X7'-O" sliders. b) Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface. Please show it on plans for the following windows: (N) 3040 adjacent to the (N) French Door (adjacent to the (N) Fireplace)at the Front of the (E) Living. (N) 2030 at toilet compartment of (N) Master Bathroom. (N) 3050 at (N) Master Bathroom. For the window adjacent to Door and also for the windows adjacent to Bath-Tub. (N)2650 adjacent to (N) French Door at (E) M> Bedroom. 10. Sleeping rooms shall have a window or exterior door for emergency escape. Sill height shall not exceed 44" above the floor. Windows must have an openable area of at least 5.7 square feet with the minimum openable width 20" and the minimum openable height 24". The emergency door or window shall be openable from the inside to provide a full, clear opening without the use of separate tools. Section 310.4. a) Clearly show on plans the tve of all windows (casement, single hung, fixed, slider, etc.), and also show if they are (E) existing or (N) new. Additional corrections may follow. Please show on the plans at their location the type of window that will be installed. Also please note that the SH (single hung) windows which are less than 5' height will not comply with the minimum openable height of 24" required. Original correction is still applicable. City of Carlsbad 07-1655 August 13, 2007 12. Openable window area in habitable rooms must be 1/20 of the floor area and a minimum of 5 square feet. In bathrooms and water closet compartments, 1/20 of area is required and minimum is 1.5 sq. ft. Section 1203.3. a) Clearly show on plans the type of all windows (casement, single hung, fixed, slider, etc.), and also show if they are (E) existing or (N) new. Additional corrections may follow. The type of the (N) windows is not shown on the floor plans at their location, for example there is not shown at (N) Bedroom #4 and #4, etc. Original correction is still applicable. 14. Provide mechanical ventilation capable of providing five air changes per hour in bathrooms and water closet compartments if required openable windows are not provided. Section 1203.3. The type of the (N) windows is not shown on the floor plans at their location. Original correction is still applicable. Dimension on the plans 30" clear width for water closet compartments and 24" clearance in front of water closet. Section 2904. Please clearly show the dimensions in front of the water closets as for example at the toilet compartment of the (N) Master Bathroom, etc. Original correction is still applicable. Guardrails (Section 509.1): Shall be installed at open sides of landings. Shall have a height of 36". Shall be detailed showing adequacy of connections to resist the horizontal force prescribed in Table 16-13. Openings between railings shall be less than 4". The triangular openings formed by the riser, tread and bottom element of a guardrail at a stair shall be less than 6". A general note will not be adequate to resolve this correction. Provide the complete guardrail details and cross-reference from details to all applicable locations on the floor plans. Additional corrections may follow. 16. Provide stairway and landing details. Sections 1003.3.3. a) Maximum rise is 7" and minimum run is 11". When the stairs serves less than 10 occupants, or serves an unoccupied roof, rise may be 8" maximum and run 9" minimum. Cross-reference the general note on sheet 008 to the floor plans at all applicable new stairs. Every stairway landing shall have a dimension, measured in the direction of travel, at least equal to the stairway width. If a door occurs at the landing, such dimension need not exceed 36 inches. Sections 1003.3.3.5 and 1003.3.1.7. An interior door may open at a landing that is not more than 8" lower than the floor level, provided the door does not swing over the landing. Section 1003.3.1.6. The (N) French Door between the (N) Hall and the (E) Deck shall not be opening over the steps. b) Minimum width is 36". Please show the applicable inside dimension on plans for all new stairways. City of Carlsbad 07-1655 August 13, 2007 19. Handrails (Section 1003.3.3.6): a) Handrails and extensions shall be 34" to 38" above nosing of treads and be continuous. Please show it on plans for all new stairs. 20. Provide spiral stairway details, per Section 1003.3.3.8.3: Minimum run is 7-1/2 inches measured at a point 12 inches from where the treads are the narrowest. Maximum rise is 9-1/2 inches. Maximum clear opening between risers is 4 inches. Minimum headroom is 6 feet 6 inches. The tread must provide a clear walking area measuring at least 26 inches from the outer edge of the supporting column to the inner edge of the handrail. The information provided is not adequate to resolve this correction. All applicable construction details and calculations are missing for the "Spiral Stairway. Original correction is still applicable. The required information shall be included in the plans. 21. Provide I.C.B.O. Research Report and number for metal stairway, or submit plans and calculations and approved fabricator registered with the building department or note that the stairway fabrication plans shall be submitted to and approved by the building official prior to installation. The required ICBO approval number was not provided. Original correction is still applicable. 27. Please show on the floor plans the location of the New Deck shown on sheet 008a. Additional corrections may follow. Section 106.3.3. The required information was not provided. Original correction is still applicable. Show a self-closing door, either 1-3/8" solid core or a listed 20 minute assembly, for openings between garage and dwelling. Section 302.4. a) Please show it on plans for the door between the Garage and breezeway on the North Side of the Garage. The required information was not provided. Original correction is still applicable. Doors may open into the garage only if the floor or landing in the garage is not more than one inch lower than the door threshold. Section 1003.3.1.6. a) Please show it on plans for the door between the Garage and breezeway on the North Side of the Garage. The required information was not provided. Original correction is still applicable. Provide a copy of the project soil report prepared by a California licensed architect or civil engineer. The report shall include foundation design recommendations based on the engineer's findings and shall comply with UBC Section 1804. a) According to the CARLSBAD SPECIAL CODE REQUIREMENTS: all new residential buildings, including additions, require a soils report. The required soils report was not provided. Original correction is still applicable. City of Carlsbad 07-1655 August 13, 2007 37. The "SPECIAL INSPECTION PROGRAM", included on sheet SCS, show that "Prestressed/Postension Concrete", as one of the items. Please clearly show on plans where the "Prestressed/Postension Concrete" is. Additional corrections may follow. No written response was provided for this correction. Original correction is still applicable. 38. Show anchored veneer support and connections attached to wood in Seismic Zones 3 and 4, comply with Section 1403. Show ties, #9 wire in horizontal joints, etc. Plans are still showing "CORONADO STONE VENEER". Original correction is still applicable. 39. From the structural design calculations provided the following corrections are applicable: Please clarify why? The concentrated load from the second floor shear wall hold-down and post, was not included in the design of the Flush Beam #6. 40. From the structural design calculations provided the following corrections are applicable: Please show on plans all grid lines identified using the same identification number used in the structural design calculations. Please clearly show why? The roof areas at the Master Bedroom were not included within the lateral analysis. Please show how? The Front area of the New Deck will be supported for lateral loads. (only one line of resistance "13" was provided for this area). CARLSBAD SPECIAL CODE REQUIREMENTS 47. Nails for shear transfer connection (using A35's, etc.) may not be driven parallel to the flanges of TJI's (i.e., along the sides), per city policy, unless specific written approval from Trus-Joist Macmillan is first obtained. Details or notes on the plans should make this clear. Nails may be driven perpendicular to TJI flanges. No written response was provided for this correction. Original correction is still applicable. If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. Thank you. EsGil Corporation In cPartnership with government for Bui(iing Safety DATE: July 26, 2007 C3 —AgRLIQANT 0 JURIS. JURISDICTION: City of Carlsbad 0 PLAN REVIEWER 0 FILE PLAN CHECK NO.: 071655 SET: II PROJECT ADDRESS: 2330 Spruce St. PROJECT NAME: Conboy Residence/SFD Addition and Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. LII The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. LII The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. F-1 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. Lnj The applicant's copy of the check list has been sent to: Steve Conboy 2330 Spruce St., Carlsbad, CA 92008 LI Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Ste e Conboy Date contactedPh/01(by: 44 MaiK/4eIephone Fax ,/1n Person Eli REMARKS: By: Sergio Azuela Esgil Corporation [I GA E] MB DEJ [I PC Telephone #: (760) 730-3951 Fax #: (760) 720-9886 Enclosures: 07/19 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad 07-1655 July 26, 2007 RECHECK PLAN CORRECTION LIST JURISDICTION: City of Carlsbad PROJECT ADDRESS: 2330 Spruce St. DATE PLAN RECEIVED BY ESGIL CORPORATION: 07/19 REVIEWED BY: Sergio Azuela FOREWORD (PLEASE READ): PLAN CHECK NO.: 07-1655 SET: II DATE RECHECK COMPLETED: July 26, 2007 This plan review is limited to the technical, requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations; Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? DYes ONo City of Carlsbad 07-1655 July 26, 2007 Please make all corrections, as requested in the correction list. Submit three new complete sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department ford routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). When special inspection is required, the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit. Please review Section 106.3.5. Please complete the attached form. a) If special inspection is required, the designer shall complete the attached Special Inspection Notice. On the cover sheet of the plans, specify any items that will have a deferred submittal (trusses, etc.). Identify existing walls to be removed, existing walls to remain and proposed new walls. Section 106.3.3. Clearly show it on plans for the new walls, also please identify all the symbols at the first and second floor plans. Show locations of permanently wired smoke detectors with battery backup: a) Inside each bedroom. Missing at Bedroom #1 on the first floor and at (E) Master Bedroom on the 2nd floor. b) Centrally located in corridor or area giving access to sleeping rooms. Missing at area giving access to Bedroom #1 on the first floor. c) On each story. Missing at Sitting Room on the 2' floor. f) In rooms adjacent to hallways serving bedrooms, when such rooms have a ceiling height 24 inches or more above the ceiling height in the hallway. City of Carlsbad 07-1655 July 26, 2007 9. Glazing in the following locations should be of safety glazing material in accordance with Section 2406.4 (see exceptions): Fixed and sliding panels of sliding door assemblies and panels in swinging doors other than wardrobe doors. Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface. Individual fixed or operable panels, other than those locations described above, that meet all of the following conditions: Exposed area of an individual pane is greater than 9 square feet, and: Exposed bottom edge is less than 18 inches above the floor, and: Exposed top edge is greater than 36 inches above the floor, and: One or more walking surfaces are within 36 inches horizontally of the plane of the glazing. Please show it on plans for each specific applicable door and window. The windows and doors information provided on plans is not readable. Additional corrections may follow. 10. Sleeping rooms shall have a window or exterior door for emergency escape. Sill height shall not exceed 44" above the floor. Windows must have an openable area of at least 5.7 square feet with the minimum openable width 20" and the minimum openable height 24". The emergency door or window shall be openable from the inside to provide a full, clear opening without the use of separate tools. Section 310.4. a) Clearly show on plans the type of all windows (casement, single hung, fixed, slider, etc.), and also show if they are (E) existing or (N) new. Additional corrections may follow. The windows and doors information provided on plans is not readable. Additional corrections may follow. 11. Window area must be at least 1/10 of the floor area and a minimum of 10 square feet per Section 1203.3. a) Please show it on plans at Bedroom #3. The windows and doors information provided on plans is not readable. Additional corrections may follow. 12. Openable window area in habitable rooms must be 1/20 of the floor area and a minimum of 5 square feet. In bathrooms and water closet compartments, 1/20 of area is required and minimum is 1.5 sq. ft. Section 1203.3. a) Clearly show on plans the type of all windows (casement, single hung, fixed, slider, etc.), and also show if they are (E) existing or (N) new. Additional corrections may follow. The windows and doors information provided on plans is not readable. Additional corrections may follow. 14. Provide mechanical ventilation capable of providing five air changes per hour in bathrooms and water closet compartments if required openable windows are not provided. Section 1203.3. City of Carlsbad 07-1655 July 26, 2007 Note that the discharge point for exhaust air will be at least 3 feet from any opening which allows air entry into occupied portions of the building. Section 1203.3. No written response was provided for this correction. Original correction is still applicable. Dimension on the plans 30" clear width for water closet compartments and 24" clearance in front of water closet. Section 2904. No written response was provided for this correction. Original correction is still applicable. Guardrails (Section 509.1): Shall be installed at open sides of landings. Shall have a height of 36". Shall be detailed showing adequacy of connections to resist the horizontal force prescribed in Table 16-13. Openings between railings shall be less than 4". The triangular openings formed by the riser, tread and bottom element of a guardrail at a stair shall be less than 6". Provide the complete guardrail details and cross-reference from details to all applicable locations on the floor plans. Additional corrections may follow. 16. Provide stairway and landing details. Sections 1003.3.3. Maximum rise is 7" and minimum run is 11". When the stairs serves less than 10 occupants, or serves an unoccupied roof, rise may be 8" maximum and run 9" minimum. Cross-reference the general note on sheet 008 to the floor plans at all applicable new stairs. Minimum width is 36". Please show the applicable inside dimension on plans for all new stairways. 19. Handrails (Section 1003.3.3.6): a) Handrails and extensions shall be 34" to 38" above nosing of treads and be continuous. Please show it on plans for all new stairs. 20. Provide spiral stairway details, per Section 1003.3.3.8.3: Minimum run is 7-1/2 inches measured at a point 12 inches from where the treads are the narrowest. Maximum rise is 9-1/2 inches. Maximum clear opening between risers is 4 inches. Minimum headroom is 6 feet 6 inches. The tread must provide a clear walking area measuring at least 26 inches from the outer edge of the supporting column to the inner edge of the handrail. No written response was provided for this correction. Original correction is still applicable. The required information shall be included in the plans. 21. Provide I.C.B.O. Research Report and number for metal stairway, or submit plans and calculations and approved fabricator registered with the building department or note that the stairway fabrication plans shall be submitted to and approved by the building official prior to installation. No written response was provided for this correction. Original correction is still applicable. City of Carlsbad 07-1655 July 26, 2007 Specify roof slope. The information provided on plans is not readable. Please revise the plans and provide readable information. Please show on the floor plans the location of the New Deck shown on sheet 008a. Additional corrections may follow. Section 106.3.3. No written response was provided for this correction. Original correction is still applicable. 28. Show the required ventilation for attics (or enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters). The minimum vent area is 1/150 of attic area (or 1/300 of attic area if at least 50% of the required vent is at least 3 feet above eave vents or cornice vents). Show area required and area provided. Section 1505.3. No written response was provided for this correction. Original correction is still applicable. 29. Where eave vents are installed, insulation shall not block the free flow of air. A minimum of 1" of air space shall be provided between the insulation and the roof sheathing. To accommodate the thickness of insulation plus the required 1" clearance, member sizes may have to be increased for rafter-ceiling joists. Section 1505.3. No written response was provided for this correction. Original correction is still applicable. 30. Note on the plans: "Attic ventilation openings shall be covered with corrosion-resistant metal mesh with mesh openings of 1/4-inch in dimension." Section 1505.3. No written response was provided for this correction. Original correction is still applicable. Garage requires one-hour fire protection (i.e., 5/8" Type X drywall) on the garage side of walls and ceiling common to the dwelling. Table-,3-B, Section 302.4. a) Please show it on plans for the walls between the Garage and the New Family Room, as well as, between the Garage and the breezeway on the North Side of the Garage. The information provided on plans is not readable. Please revise the plans and provide readable information. Show a self-closing door, either 1-3/8" solid core or a listed 20 minute assembly, for openings between garage and dwelling. Section 302.4. a) Please show it on plans for the door between the Garage and breezeway on the North Side of the Garage. The information provided on plans is not readable. Please revise the plans and provide readable information. Doors may open into the garage only if the floor or landing in the garage is not more than one inch lower than the door threshold. Section 1003.3.1.6. a) Please show it on plans for the door between the Garage and breezeway on the North Side of the Garage. The required information was not provided. Original correction is still applicable. City of Carlsbad 07-1655 July 26, 2007 Provide a copy of the project soil report prepared by a California licensed architect or civil engineer. The report shall include foundation design recommendations based on the engineer's findings and shall comply with UBC Section 1804. a) According to the CARLSBAD SPECIAL CODE REQUIREMENTS: all new residential buildings, including additions, require a soils report. The required soils report was not provided. Original correction is still applicable. Note on plans that surface water will drain away from building and show drainage pattern. Section 1804.7. The required information was not provided. Original correction is still applicable. Show distance from foundation to edge of cut or fill slopes ("distance-to-daylight") and show slope and heights of cuts and fills. Chapter 18. The required information was not provided. Original correction is still applicable. The "SPECIAL INSPECTION PROGRAM", included on sheet SCS, show that "Prestressed/Postension Concrete", as one of the items. Please clearly show on plans where is the "Prestressed/Postension Concrete". Additional corrections may follow. No written response was provided for this correction. Original correction is still applicable. 38. Show anchored veneer support and connections attached to wood in Seismic Zones 3 and 4, comply with Section 1403. Show ties, #9 wire in horizontal joints, etc. No written response was provided for this correction. Original correction is still applicable. Provide calculations for main vertical and horizontal framing members and footings. Section 106.3.3. The required calculations were not provided. Original correction is still applicable. Provide calculations for lateral loads, shear panels, shear transfer and related. Section 106.3.3. The required calculations were not provided. Original correction is still applicable. Specify nail size and spacing for floor and roof diaphragms. Indicate required blocking. Maintain maximum diaphragm dimension ratios. Sections 2315 and 2513. No written response was provided for this correction. Original correction is still applicable. 42. The regulations require a properly completed and properly signed Form CF-1 R (4 pages) to be either imprinted on the plans, taped to the plans or "sticky backed" on the plans, to allow the building inspector to readily compare the actual construction with the requirements of the approved energy design. Owner/Designer signature is missing. No written. response was provided for this correction. Original correction is still applicable. City of Carlsbad 07-1655 July 26, 2007 43. Show on the plans compliance with the residential energy lighting requirements (Mandatory requirement): In the kitchen at least one-half of the wattage rating of the fixtures must be high efficacy with non-high efficacy fixtures switched separately. Note: Approximately 3/4 of the fixtures will be required to be of the high efficacy variety. In bathrooms, garages, laundry rooms, and utility rooms all fixtures must be high efficacy style or be controlled by a manually-on occupancy sensor. All other rooms require any installed fixtures to be high efficacy or be controlled by a manually-on occupancy sensor or dimmer. (Closets under 70 square feet are exempt). Outdoor lighting fixtures are required to be high efficacy or controlled by a combination photocontrol/motion sensor. Note: Generally a high efficacy style of fixture is fluorescent complete with electronic ballasts. Regular incandescent, quartz halogen and halogen MR lamps do not comply. No written response was provided for this correction. Original correction is still applicable. 44. Specify on the plans the following information for the fireplace(s), per Section 106.3.3: Model name/number. Please show it on plans ICBO approval number, or equal. Please show it on plans Show height of chimney above roof per I.C.B.O. approval or UBC Table 31-B. Please show it on plans Note on the plans that approved spark arrestors shall be installed on all chimneys. UBC, Section 3102.3.8. Please show it on plans No written response was provided for this correction. Original correction is still applicable. CARLSBAD SPECIAL CODE REQUIREMENTS 46. If special inspection is required, the designer shall complete the attached Special Inspection Notice. No written response was provided for this correction. Original correction is still applicable. 47. Nails for shear transfer connection (using A35's, etc.) may not be driven parallel to the flanges of TJl's (i.e., along the sides), per city policy, unless specific written approval from Trus-Joist Macmillan is first obtained. Details or notes on the plans should make this clear. Nails may be driven perpendicular to TJI flanges. No written response was provided for this correction. Original correction is still applicable. If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. Thank you. EsGil Corporation In cPartnersliip with çovernment for tBuilding safety DATE: June 26, 2007 0 APPLICANT JURISDICTION: City of Carlsbad REVIEWER 0 FILE- PLAN CHECK NO.: 07-1655 SET: I PROJECT ADDRESS: 2330 Spruce St. PROJECT NAME: Conboy Residence/SFD Addition and Remodel i1 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. LI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. LII The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. LII The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Steve Conboy 2330 Spruce St., Carlsbad, CA 92008 LI Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Steve Conboy Telephone #: (760) 730-3951 Date 7Telephone tacted/2P'/o1(bi4 Fax #: (760) 720-9886 Mail /Fax ,/In Person LI REMARKS: (VA ) By: Sergio Azuela Enclosures: Esgil Corporation 0 GA 0 MB 0 EJ 0 PC 06/19 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad 07-1655 June 26, 2007 GENERAL PLAN CORRECTION LIST JURISDICTION: City of Carlsbad PLAN CHECK NO.: 07-1655 PROJECT ADDRESS: 2330 Spruce St. DATE PLAN RECEIVED BY DATE REVIEW COMPLETED: ESGIL CORPORATION: 06/19 June 26, 2007 REVIEWED BY: Serio Azuela FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? El Yes DNo City of Carlsbad 07-1655 June 26, 2007 Please make all corrections, as requested in the correction list. Submit three new complete sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). When special inspection is required, the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit. Please review Section 106.3.5. Please complete the attached form. a) If special inspection is required, the designer shall complete the attached Special Inspection Notice. On the cover sheet of the plans, specify any items that will have a deferred submittal (trusses, etc.). Additionally, provide the following note on the plans, per Sec. 106.3.4.2: "Submittal documents for deferred submittal items shall be submitted to the architect or engineer of record, who shall review them and forward them to the building official with a notation indicating that the deferred submittal documents have been reviewed and that they have been found to be in general conformance with the design of the building. The deferred submittal items shall NOT be installed until their design and submittal documents have been approved by the building official." Identify existing walls to be removed, existing walls to remain and proposed new walls. Section 106.3.3. Show locations of permanently wired smoke detectors with battery backup: Inside each bedroom. Centrally located in corridor or area giving access to sleeping rooms. On each story. In the basement, if part of the dwelling unit. When sleeping rooms are upstairs, at the upper level in close proximity to the stair. In rooms adjacent to hallways serving bedrooms, when such rooms have a ceiling height 24 inches or more above the ceiling height in the hallway. NOTE: Detectors shall sound an alarm audible in all sleeping areas of the unit. Section 310.9.1. City of Carlsbad 07-1655 June 26, 2007 7. When the valuation of a room addition or repair exceeds $1,000, or when sleeping rooms are created, smoke detectors shall be provided per the above, except that smoke detectors added at existing construction need only be battery powered. Section 310.9.1.2. 8. Please include the in the first floor plan the rooms on the North Side, which are under the Sitting Room and Bathroom shown on the North Side of the second floor plan. Section 106.3.3. 9. Glazing in the following locations should be of safety glazing material in accordance with Section 2406.4 (see exceptions): Fixed and sliding panels of sliding door assemblies and panels in swinging doors other than wardrobe doors. Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface. Individual fixed or operable panels, other than those locations described above, that meet all of the following conditions: Exposed area of an individual pane is greater than 9 square feet, and: Exposed bottom edge is less than 18 inches above the floor, and: Exposed top edge is greater than 36 inches above the floor, and: One or more walking surfaces are within 36 inches horizontally of the plane of the glazing. 10. Sleeping rooms shall have a window or exterior door for emergency escape. Sill height shall not exceed 44" above the floor. Windows must have an openable area of at least 5.7 square feet with the minimum openable width 20" and the minimum openable height 24". The emergency door or window shall be openable from the inside to provide a full, clear opening without the use of separate tools. Section 310.4. a) Clearly show on plans the type of all windows (casement, single hung, fixed, slider, etc.), and also show if they are (E) existing or (N) new. Additional corrections may follow. 11. Window area must be at least 1/10 of the floor area and a minimum of 10 square feet per Section 1203.3. a) Please show it on plans at Bedroom # 3. 12. Openable window area in habitable rooms must be 1/20 of the floor area and a minimum of 5 square feet. In bathrooms and water closet compartments, 1/20 of area is required and minimum is 1.5 sq. ft. Section 1203.3. a) Clearly show on plans the type of all windows (casement, single hung, fixed, slider, etc.), and also show if they are (E) existing or (N) new. Additional corrections may follow. 13. At least 1/2 of the common wall must be open and have an opening not less than 25 sq. ft., nor one tenth of the floor area of the interior room, if light and ventilation is being supplied from an adjacent room. Section 1203.1. a) Show it at the (E) Kitchen. 'City of Carlsbad 07-1655 June 26, 2007 14. Provide mechanical ventilation capable of providing five air changes per hour in bathrooms and water closet compartments if required openable windows are not provided. Section 1203.3. 15. Note that the discharge point for exhaust air will be at least 3 feet from any opening which allows air entry into occupied portions of the building. Section 1203.3. 16. Dimension on the plans 30" clear width for water closet compartments and 24" clearance in front of water closet. Section 2904. 17. Guardrails (Section 509.1): Shall be installed at open sides of landings. Shall have a height of 36". Shall be detailed showing adequacy of connections to resist the horizontal force prescribed in Table 16-13. Openings between railings shall be less than 4". The triangular openings formed by the riser, tread and bottom element of a guardrail at a stair shall be less than 6". 18. Provide stairway and landing details. Sections 1003.3.3. Maximum rise is 7" and minimum run is 11". When the stairs serves less than 10 occupants, or serves an unoccupied roof, rise may be 8" maximum and run 9" minimum. Cross-reference the general note on sheet 008 to the floor plans at all applicable new stairs. Minimum width is 36". Please show the applicable inside dimension on plans for all new stairways. 19. Handrails (Section 1003.3.3.6): a) Handrails and extensions shall be 34" to 38" above nosing of treads and be continuous. Please show it on plans for all new stairs. 20. Provide spiral stairway details, per Section 1003.3.3.8.3: Minimum run is 7-1/2 inches measured at a point 12 inches from where the treads are the narrowest. Maximum rise is 9-1/2 inches. Maximum clear opening between risers is 4 inches. Minimum headroom is 6 feet 6 inches. The tread must provide a clear walking area measuring at least 26 inches from the outer edge of the supporting column to the inner edge of the handrail. 21. Provide I.C.B.O. Research Report and number for metal stairway, or submit plans and calculations and approved fabricator registered with the building department or note that the stairway fabrication plans shall be submitted to and approved by the building official prior to installation. 22. The walls and soffits of the enclosed usable space under interior stairs shall be protected on the enclosed side as required for one hour fire-resistive construction. Section 1003.3.3.9. 23. Specify roof material and application. Chapter 15. City of Carlsbad 07-1655 June 26, 2007 24. Specify on the plans the following information for the roof materials, per Section 106.3.3: Manufacturers name. Product name/number. ICBO approval number, or equal. 25. Per local ordinance, a Class "A" roof is required. 26. Specify roof slope. 27. Please show on the floor plans the location of the New Deck shown on sheet 008a. Additional corrections may follow. Section 106.3.3. 28. Show the required ventilation for attics (or enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters). The minimum vent area is 1/150 of attic area (or 1/300 of attic area if at least 50% of the required vent is at least 3 feet above eave vents or cornice vents). Show area required and area provided. Section 1505.3. 29. Where eave vents are installed, insulation shall not block the free flow of air. A minimum of 1" of air space shall be provided between the insulation and the roof sheathing. To accommodate the thickness of insulation plus the required 1" clearance, member sizes may have to be increased for rafter-ceiling joists. Section 1505.3. 30. Note on the plans: "Attic ventilation openings shall be covered with corrosion-resistant. metal mesh with mesh openings of 1/4-inch in dimension." Section 1505.3. 31. Garage requires one-hour fire protection (i.e., 5/8" Type X drywall) on the garage side of walls and ceiling common to the dwelling. Table 3-13, Section 302.4. a) Please show it on plans for the walls between the Garage and the New Family Room, as well as, between the Garage and the breezeway on the North Side of the Garage. 32. Show a self-closing door, either 1-3/8" solid core or a listed 20 minute assembly, for openings between garage and dwelling. Section 302.4. a) Please show it on plans for the door between the Garage and breezeway on the North Side of the Garage. 33. Doors may open into the garage only if the floor or landing in the garage is not more than one inch lower than the door threshold. Section 1003.3.1.6. a) Please show it on plans.for the door between the Garage and breezeway on the North Side of the Garage. 34. Provide a copy of the project soil report prepared by a California licensed architect or civil engineer. The report shall include foundation design recommendations based on the engineer's findings and shall comply with UBC Section 1804. a) According to the CARLSBAD SPECIAL CODE REQUIREMENTS: all new residential buildings, including additions, require a soils report. City of Carlsbad 07-1655 June 26, 2007 Note on plans that surface water will drain away from building and show drainage pattern. Section 1804.7. Show distance from foundation to edge of cut or fill slopes ("distance-to-daylight") and show slope and heights of cuts and fills. Chapter 18. The "SPECIAL INSPECTION PROGRAM", included on sheet SCS, show that "Prestressed/Postension Concrete", as one of the items. Please clearly show on plans where is the "Prestressed/Postension Concrete". Additional corrections may follow. Show anchored veneer support and connections attached to wood in Seismic Zones 3 and 4, comply with Section 1403. Show ties, #9 wire in horizontal joints, etc. Provide calculations for main vertical and horizontal framing members and footings. Section 106.3.3. Provide calculations for lateral loads, shear panels, shear transfer and related. Section 106.3.3. Specify nail size and spacing for floor and roof diaphragms. Indicate required blocking. Maintain maximum diaphragm dimension ratios. Sections 2315 and 2513. The regulations require a properly completed and properly signed Form CF-1 R (4 pages) to be either imprinted on the plans, taped to the plans or "sticky backed" on the plans, to allow the building inspector to readily compare the actual construction with the requirements of the approved energy design. Owner/Designer signature is missing. Show on the plans compliance with the residential energy lighting requirements (Mandatory requirement): In the kitchen at least one-half of the wattage rating of the fixtures must be high efficacy with non-high efficacy fixtures switched separately. Note: Approximately 3/4 of the fixtures will be required to be of the high efficacy variety. In bathrooms, garages, laundry rooms, and utility rooms all fixtures must be high efficacy style or be controlled by a manually-on occupancy sensor. All other rooms require any installed fixtures to be high efficacy or be controlled by a manually-on occupancy sensor or dimmer. (Closets under 70 square feet are exempt). Outdoor lighting fixtures are required to be high efficacy or controlled by a combination photocontrol/motion sensor. Note: Generally a high efficacy style of fixture is fluorescent complete with electronic ballasts. Regular incandescent, quartz halogen and halogen MR lamps do not comply. City of Carlsbad 07-1655 June 26, 2007 44. Specify on the plans the following information for the fireplace(s), per Section 106.3.3: Manufacturer's name. Model name/number. ICBO approval number, or equal. Show height of chimney above roof per I.C.B.O. approval or UBC Table 31-13. Note on the plans that approved spark arrestors shall be installed on all chimneys. UBC, Section 3102.3.8. This correction is applicable to the Metal Fireplace shown on plans at the Existing Living Room, only if the Fireplace is new. 45. Please provide the electrical plans for the second floor. Section 106.3.3. CARLSBAD SPECIAL CODE REQUIREMENTS 46. If special inspection is required, the designer shall complete the attached Special Inspection Notice. 47. Nails for shear transfer connection (using A35's, etc.) may not be driven parallel to the flanges of TJl's (i.e., along the sides), per city policy, unless specific written approval from Trus-Joist Macmillan is first obtained. Details or notes on the plans should make this clear. Nails may be driven perpendicular to TJI flanges. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. Thank you. City of Carlsbad 07-1655 June 26, 2007 City of Carlsbad ml r li.. - .-i iii BUILDING DEPARTMENT NOTICE OF REQUIREMENT FOR SPECIAL INSPECTION Do Not Remove From Plans Plan Check No. 07-1655 Job Address or Legal Description 2330 Spruce St. Owner Address You are hereby notified that in addition to the inspection of construction provided by the Building Department, an approved Registered Special Inspector is required to provide continuous inspection during the performance of the phases of construction indicated on the reverse side of this sheet. The Registered Special Inspector shall be approved by the City of Carlsbad Building Department prior to the issuance of the building permit. Special Inspectors having a current certification from the City of San Diego, Los Angeles, or ICBO are approved as Special Inspectors for the type of construction for which they are certified. The inspections by a Special Inspector do not change the requirements for inspections by personnel of the City of Carlsbad building department. The inspections by a Special Inspector are in addition to the inspections normally required by the County Building Code. The Special Inspector is not* authorized to inspect and approve any work other than that for which he/she is specifically assigned to inspect. The Special Inspector is not authorized to accept alternate materials, structural changes, or any requests for plan changes. The Special Inspector is required to submit written reports to the City of Carlsbad building department of all work that he/she inspected and approved. The final inspection approval will not be given until all Special Inspection reports have been received and approved by the City of Carlsbad building department. Please submit the names of the inspectors who will perform the special inspections on each of the items indicated on the reverse side of this sheet. (over) City of Carlsbad 07-1655 June 26, 2007 SPECIAL INSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION: PLAN CHECK NUMBER: OWNER'S NAME: I, as the owner, or agent of the owner (contractors may not employ the special inspector), certify that I, or the architect/engineer of record, will be responsible for employing the special inspector(s) as required by Uniform Building Code (U BC) Section 1701.1 for the construction project located at the site listed above. UBC Section 106.3.5. Signed I, as the engineer/architect of record, certify that I have prepared the following special inspection program as required by UBC Section 106.3.5 for the construction project located at the site listed above. EnglneersIArchitect's Seal & Signature Here Signed 1. List of work requiring special inspection: 0 Soils Compliance Prior to Foundation Inspection LI Field Welding E Structural Concrete Over 2500 PSI LI High Strength Bolting 0 Prestressed Concrete U Expansion/Epoxy Anchors O Structural Masonry U Sprayed-On Fireproofing U Designer Specified U Other 2. Name(s) of individual(s) or firm(s) responsible for the special inspections listed above: 3. Duties of the special inspectors for the work listed above: Special inspectors shall check in with the City and present their credentials for approval prior to beginning work on the job site. City of Carlsbad 07-1655 June 26, 2007 VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: 07-1655 PREPARED BY: Sergio Azuela BUILDING ADDRESS: 2330 SpruceSt. BUILDING OCCUPANCY: R-3 & U-i DATE: June 26, 2007 Conboy Residence/SFD Add./Rem. TYPE OF CONSTRUCTION: V-N BUILDING 1PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Dwelling Add. 1026 121.94 125,110 Dwelling Rem. 150 34.37 5,156 Air Conditioning 1026 3.88 3,981 Fire Sprinklers _ TOTAL VALUE 134,247 Jurisdiction Code 1cb 113y Ordinance Bldg. Permit Fee by Ordinance I I $654.36 I Plan Check Fee by Ordinance v I $425.331 Type of Review: El Complete Review 11 Structural Only 0 Other 0 Repetitive Fee Repeats Hourly I Hour * $366.44 I I Plan Review Fee vi Esgi Comments: Sheet I of I macvalue.doc City of Carlsbad Iiri .i i - Engi neeri ng BUILDING PLANCHECK CHECKLIST DATE: T7/OZ/D PLANCHECK NO.: CBO7 (4 BUILDING AbDRES: 0_ IUC6 cQ PROJECT DESCRIPTION: JS:,/-1L, ASSESSOR'S PARCEL NUMBER: G5-1 ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. A Right-of-Way permit is required prior to construction of the following improvements: DENIAL Please s th attached report of deficiencies marked wik 0.)lake necessary corrections to plans or specifichires for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. By: Date: FOR OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMV 5o24-47 S Bw1aA, Date: ATTACHMENTS Dedication Application Dedication Checklist 0 Improvement Application 0 Improvement Checklist 0 Future Improvement Agreement 0 Grading Permit Application 0 Grading Submittal Checklist 0 Right-of-Way Permit Application Right-of-Way Permit Submittal Checklist and Information Sheet 0 Sewer Fee Information Sheet ENGINEERING DEPT. CONTACT PERSON Name: Linda Ontiveros City of Carlsbad Address: 1635 Faraday Avenue, Carlsbad, CA 92008 Phone: (760) 602-2773 CFD INFORMATION Pallo: Lots: Recordation: Recordation: Carlsbad Tract: E-Pk3 1635 Faraday Faraday Avenue Carlsbad, CA 92008-7314 • (760) 602-2720 • FAX (760) 602-8562 BUILDING PLANCHECK CHECKLIST SITE PLAN 3R0 .. El 1. Provide a fully dimensiQned sit a J526- ATfA-CKE-J 5J (VTt NAL wpe 1'pCirth Arrow ght-of-Way Width & Adjacent Streets Bxisting & Proposed Structures cj4Oiveway widths (Eisting Street Improvements -xisting or proposed sewer lateral operty Lines -4 IO!1 E1sting or proposed water service . - ements xisting or proposed irrigation service on site plan: rainage Patterns - Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive d inage of 2% to swale 5' away from building." isting & Proposed Slopes and Topography ize, type, location, alignment of existing or proposed sewer and water service (s) at serves the project. Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception. D. Sewer and water laterals should not be located within proposed driveways, per standards. O 0 • 3. Include on title sheet: J,ç('Site address - 1[2j' Assessor's Parcel Number egal Description, ;. For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION C:Save stuff he,eBUILDING PLANCHECI( CKLST FORM= 2 Rev. 7114100 BUILDING PLANCHECK CHECKLIST 1ST 2ND RD DISCRETIONARY APPROVAL COMPLIANCE 4a. Project does not comply with the following Engineering Conditions of approval for Project No. E 4b. All conditions are in compliance. Date: DEDICATION REQUIREMENTS fl 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required-for all new buildings and for remodels with a value at or exceeding $_15.000 , pursuant to Carlsbad Municipal Code Section 18.40.030. Dedication required as follows: Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 1,41' x 11" plat map and submit with a titlereport. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication processa Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completed by: Date: IMPROVEMENT REQUIREMENTS 0 0 6a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $_75.000 , pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required as follows: Attached please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on the CSsve stuff heretBUut.DING PLANCHECK CKLST FORMA= Rev. 7114100 BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD checklist must be submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit. Improvement Plans signed by: Date: U U 6b. Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 18.40: Please submit a recent property title report or current grant deed on the property and processing fee of $310 so we may prepare the necessary Neighborhood Improvement Agreement. This agreement must be signed, notarized and. approved by the City prior, to issuance of a Building permit. Future public improvements required as follows: 0 0 6c. Enclosed please find your Neighborhood Improvement Agreement. Please return agreement signed and notarized to the Engineering Department. Neighborhood Improvement Agreement completed by: Date: U 6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adiacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. 0 0 7a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities (cut, fill import, export). 0 0 7b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by: Date: O 0 7c. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) C:Save stuff hereBUILDING PLANCHECK CKLST FORMA= 4 Rev. 7114100 BUILDING PLANCHECK CHECKLIST j2 ND 3R0 0 7d .No Grading Permit required.. 0 7e. If grading is not required, write "NQ Grading" on plot plan: MISCELLANEOUS PERMITS O 8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. Right-of-Way permit required for: 0 0 9. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can provide forms and assistance, and will check to.see if your business enterprise is on the EWA Exempt List. You may telephone (760) 438-2722, extension 7153, for assistance. Industrial Waste permit accepted by: Date: 0 0 10. NPDES PERMIT Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit. The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas. Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first. 0 0 0 11. Q Required fees are attached U No fees required WATER METER REVIEW Hi4.. 0 0 12a. Domestic (potable) Use Ensure that the meter, proposed by the owner/developer is not oversized. Oversized meters are inaccurate during low-flow conditions. If it is oversized, for the life of the meter, the City will not accurately bill the owner for the water used. All single family dwelling units received "standard" 1" service with 5/8" service. C:Save stuff bere8UIf.DlNG PLANCHECK CKLST FORM= 5 Rev. 7114100 BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm). A typical fixture count and water demand worksheet is attached. Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit. Maximum service and meter size is a 2" service with a 2" meter. If a developer is proposing a meter greater than 2", suggest the installation of multiple 2" services as needed to provide the anticipated demand. (manifolds are considered on case by case basis to limit multiple trenching into the street). 0 0 0 12b. Irrigation Use (where recycled cwater is not available) All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval. The developer must provide these calculations. Please follow these guidelines: If the project is a newer development (newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets. If so, at the water meter station, the demand in gpm may be listed there. Irrigation services are listed with a circled "I", and potable water is typically a circled "W". The irrigation service should look like: O STA 1+00 Install 2" service and 1.5: meter (estimated 100 gpm) If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (w/ a right of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach). Typically, Larry Black has already reviewed this if landscape plans have been prepared, but the applicant must provide the calculations to you for your use. Once you have received a good example of irrigation calculations, keep a set for your reference. In general the calculations will include: Hydraulic grade line Elevation at point of connection (POC) Pressure at POC in pounds per square inch (PSI) Worse case zone (largest, farthest away from valve Total Sprinkler heads listed (with gpm use per head) Include a 10% residual pressure at point of connection 3. In general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SF0 with no HOA). As long as the project is located within the City recycled water C:Sove stuff heqefBUILDfNG PLANCHECK CKLST FORMA= 6 Rev. 7114100 IF - - BUILDING PLANCHECK CHECKLIST 1ST 2ND RD service boundary, the City intends on switching these irrigation services/meters to a new recycled water line in the future. 0 [2 [2 12c. Irrigation Use (where recycled water is available) Recycled water meters are sized the same as the irrigation meter above. If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development. For subdivisions, this should have been identified, and implemented on the improvement plans. Installing recycled water meters is .a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees. However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge. If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund. HOwever, let the applicant know that we cannot guarantee the refund, and they must deal with the SDCWA for this. 0 [2 [2 13. Additional Comments: C:Save stuff herefBUILDING PLANCHECK CKLST FORMA= 7 Rev. 7114100 PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST (ljr,er Plan Check No. cB07 -1 40S5 Address 33D t c 2i1 riih I Planner Chris Sexton Phone (760) 602-4624 ¶1 APN: IS • OS L' P-S .M Type of Project & Use:4.4..L*(.$Y%)i Net Project Density: DU/AC Zoning Q" General Plan: IQL.J'rt Facilities Management Zone: I (f' CFD (In/out) #_Date of participation: Remaining net dev acres:______ (For non-residential development: Type of land used created by this Circle One permit:__________________________________________________ Legend: Item Complete I mincomplete - Needs your action Envlroflmentl'Revlew Required: . YES NO of-TYPE 4 , . DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which req u i r e a c t i o n . Conditions of Approval: eo 0 Discretionary Action Required: YES NO TYPE APPROVAL/RESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require a c t i o n . Conditions of Approval: O EJ15 Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES lo-NQ CA Coastal Commission Authority? YES____ NO If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402; (6 19) 767-2370 Determine status (Coastal Permit Required or Exempt): ______ 'J 0 HabltatManagementPlan .•. DataEntry Completed? YES . NO . If property has Habitat 'Type identified in Table 11 of HMP, complete HMP P e r m i t a p p l i c a t i o n a n d assess fees in Permits Plus (NP/Os, Activity Ma1tenänce, enterCB#, toolbar; Screens HMP Fees,, Enter Acres o f H a b i t a t T y p e .impacted/taken, UPDATE!) . . ., •' • 1 . 0 lncluslonary Housing Fee required: • 'YES (Effective date of lnclusionary Housing p'rdinance - May 21, 1993.) Data Entry Completed? YES NO '____ (NP/Os, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees , C o n s t r u c t H o u s i n g Y / N , Enter Fee, UPDATE!) H:ADMINCOUNTERBidgPInchkRevChkIst Rev 3/06 Site Plan: EIYO 0 Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width,. dimensional setbacks and existing topographical lines (including all side and rear yard slopes). Provide legal description of property and assessor's parcel number. Policy 44— Neighborhood Architectural Design Guidelines E'D 0 1. ApplicaIiiity: YES NO I" 0 0 0 2. Project complies YES NO Zoning: 1. Setbacks: PS Front: Required anl Shown j _'.1 Interior Side: Required ), Shown I _(O" Street Side: Required f Shown I Rear: Required 14' Shown &4' Top of slope: Required Shown O 0 0 2. Accessory structure setbacks: Front: Required Shown Interior Side: Required Shown Street Side: Required Shown Rear: Required Shown Structure separation: Required Shown O 0 ' 3. Lot Coverage: Required 4 0 7o Shown'O Height: Required 3Q1 Shown <_30 Parking: Spaces Required Q Shown (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown & 0 NP ' W A 20 OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE_________ H:ADMINC0UNTER9IdgPInchkRevChkIst Rev 3106 -- lEa irith Stra ta, un c. Geotechnlcal, Environmental and Materials Testing Consultants L BETTER PEOPLE.BETTER SERVICE .BETTER RESULTS September 20, 2007 Project No. 07205-20A Mr. Steve Conboy 2330 Spruce Street Carlsbad, California 92008 Subject: Geotechnical Review Foundation Plans for the Proposed Residence Remodel, 2330 Spruce Street, City of Carlsbad, San Diego County, California References: Earth-Strata, Inc., 2007, Geotechnical Interpretive Report, Proposed Conboy Residence Remodel, Located at 2330 Spruce Street, City of Carlsbad, San Diego County, California dated August 31. Pursuant to your request, Earth-Strata, Inc. has reviewed the Foundation Plans prepared by Performan Plus Engineering, Inc., Sheet Nos. SD-1 and SI-i dated September, 2007. The purpose of our review Wa, to evaluate the plans with regard to the geotechnical recommendations outlined in the referenced report. Our review indicates that the geotechnical recommendations outlined in the referenced report has been* incorporated into the aforementioned plans. %) Earth-Strata appreciates the opportunity to offer our consultation and advice on this project. In the event that you have any questions, please do not hesitate to contact the undersigned at your earliest convenience. Respectfully Submitted, ]EA]PLTH.STRATA, ][inc. Stlen M. Poole, PE, I Principal Engineer SMP/CW/bb Distribution: (4) Addressee EARTH -STRATA, INC. - 26047 JEFFERSON AVENUE, SUITE C, MURRIETA, CA 92562• OFFICE (951) -40 X fR fM BETTER PEOPLE • BETTER SERVICE T U TS OCT-09-2007 TUE 01:46 P11 CITY OF CARSLBAD FAX NO. 760 602 8568 P. 05 4. _ City of Carlsbad Building Department CERTIFICATE OF COMPLIANCE PAYMENT OF SCHOOL FEES OR OTHER MITIGATION This form must be completed by the City, the applicant, and the appropriate school districts and returned to the City prior to issuing a building permit. The City will not issue any building permit without a completed school fee form. Project Name: CONBOY RESIDENCE Building Permit Plan Check Number: C8071655 Project Address: 2330 SPRUCE STREET A.P.N.: 156-051.01.00 Project Applicant (Owner Name): CONBOY RESIDENCE 5n1t CO,11301 Project Description: RESIDENTIAL ADDITION Building Type: Y-N Residential: New Dwelling Units Square Feet of Living Area in New Dwelling Second Dwelling Unit: Square Feet of Living Area in SDU Residential Additions: 1026 Net Square Feet New Area Commercial/Industrial: Sgagire Feet Floor Area City Certification of Applicant Information: Date: 7_ CrLbad Unified School GZ5 F.1 Carnino Real Carlsbad CA 92009 (33 1: Vista Unified School District 1234 Arcadia Drive Vista CA 92053 (726-2170) San Marcos Unified School Dltrict 215 Meta. Way San Marcos, CA 92069(290-2649) Contact; Nancy Dolce (By Aunt. OnI Encinitas Union School District 101 South Rancho Santa Fe Rd Encinita4 CA 92024 (9444300 ext 166) San Dkguito Union High School District 710 Encinitas Blvd. Encinitas, CA 92024 (73-649I) Certification of Applicant(Owners. The person executing this declaration ("Owner) certifies under penalty of perjury that (1) the information provided above is correct and true to the best of the Owners knowledge, and that the Owner will file an amended certification of payment and pay the additional fee if Owner requests an increase in the number of dwelling units or square footage after the building permit Is Issued or if the initial determination of unite or square footage is found to be incorrect, and that (2) the Owner is the owner/developer of the above described project(s), or that the person executing this declaration is authorized to sign on behalf of the Owner. Signature: Dote: ,.-O/a e7 I. MAMAAZ OCT-09-2007 TUE 01:46 P11 CITY OF CARSLBAD FAX NO. 760 602 8558 SCHOOL DISTRICT SCHOOL FEE CERTIFICATION (To be completed by the school district(s)) THIS FORM INDICATES THAT THE SCHOOL DISTRICT REQUIREMENTS FOR THE PROJECT HAVE BEEN OR WILL BE SATISFIED. SCHOOL DISTRICT: The undersigned, being duly authorized by the applicable School District, certifies that the developer, builder, or owner has satisfied the obligation for school facilities. This is to certify that the applicant listed on page 1 has paid all amounts or completed other applicable school mitigation determined by the School District. The City may issue building permits for this project. SIGNATURE OF AUTHORIZED SCHOOL DISTRICT OFFICIAL (,iJ 0jjj IIi TITLE NAME OF SCHOOL DISTRICT DATE PHONE NUMBER WALTER FREEMAN ASSISTANT SUPERINTENDENT CARLSBAD UNIFIED SCHOOL DISTRICT 6225 EL CAMINO REAL CABLSBAD,c 92009 /O(OO7 CARLSBAD UNIFIED SCHOOL DISTRICT JEFFERSON ELEMENTARY AVIARA OAKS ELEMENTARY CARLSBAD HIGH SCHOOL MAGNOLIA ELEMENTARY AWARA OAKS MIDDLE SCHOOL Receipt No. CARLSBAD VILLAGE ACADEMY El CALA VERA HILLS SCHOOL 1-1 PACIFIC RIM 25255 VALLEY MIDDLE SCHOOL KELLEY SCHOOL CA LA VERA HILLS MIDDLE SCHOOL LIJ BUENA VISTA SCHOOL HOPE SCHOOL OTHER RECEIVED FROM: 5k Ve (?m 6 DATE: i,°- to -O f7 (If Applicable) PARENT OF ii 6,51- 01-00 PAYMENT FOR: ACCOUNT NUMBER AMOUNT 6" Ifs 10 @ 9-164 $ RECEIVED BY: __________________CASH ____ CHECK# ______ TOTAL STEVE CONBOY 484 CHERYL CONBOY 2330 SPRUCE ST. DATE _/o-/o. -0,7 CARLSBAD, CA • 92008 P ORDER AY TO OF THE I 091 PACIFIC WESTERN BANK 2 CARLSBAD, CA 92008 602 ELCAMINO REAL - CB071655 2330 SPRUCE ST - -- CONBOY: 1026SF NEW (FAM. RM, 2 BDRM, I BATH)I5OSFKIT.REMOOEL RESDNTL RAD Lot#: CONBOY STEPHEN8CHERYL w/ r' V-0-7-69j i--i- '7/( 8-) 07 pç PO-r%Q* ftthT JL'f Ogg, 008 a, ooq ckj C. i( g-zjjQp/ i 7 & y42/v7 1J Sç(L 1,Io.-1 eAc1r 3 -oi Fi ¶pdl CL!7 sl 2-1 6 77- / . 5c pry Lo -b ?CQ7-1,, 7 BUILDING t) PLANNING MpiOgUr—ENGINEERING FIREAPPRJFOR __HEALTH DEPT __HAZMAT/AIRQUAL, OTHER SEWER DISTR TO FROM & M WORKSHEET C INSP—. N cORR ea ii C4 - St#22 '/1&' Q/'7/0--7 ,'16ge op c,coi TI iTt 'P -n# IS i CO1Ap t9#C Ue.Co e.i- si o Ii5L 91WLr ¼5 14rS uo---~- V&i) 1L&O wr U4UJt I — 401 LS t'VLd 6 J-eq, - - . 7 / 07 APP LL16m' ire c cerp 1 3 e J 7 r C54 W tli9l'7107 4 7-Z) /EJa -,fooZ A2 T& 6-7 ,Wr cJC4* 4 4o 4 fL,L 10) Cca4 t r;rz.a.i jL, . '-y'.'-'c.., -, . . .• . . . . . . IS .