HomeMy WebLinkAbout2380 SPRUCE ST; ; 87-388; PermitI hereby affirm that I am licensed under
provision. of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business
and Professions Code, and my license is in
full force and effect.
I hereby affirm that I am exempt from the Contrac-
tor's License Law for the following reason (Sec 7031.5 Business and Professions Code: Any city or county whict. re' I
quires a permit to construct, alter, improve, demolish, or i repair any Structure, prior toils issuance also requires the ap- plicant for such permit to tile a signed statement that he is I
licensed pursuant to the provisions 01 the lontraclors
License Law (Chapter 9 commencing with Section 7000 of
Division 301 the Business and Professions Code) or that is en- I
empt therefrom and the basis for the alleged exemption Any
violation of Section 7031,5 by an applicant for a permit sob'
teds the applicant to a civil penalty 01001 more than tive hun' I
dred dollars ($500).
I, as owner of the properly, or my employees with wages
as their Sole compensation, will do the work, and the struc'
tore is not intended or offered for sale (Sec. 7044, Business
and Professions Code: The Contractor's License Law dons not apply to an owner of property who builds or improves
thereon and who does such work himself or through his own employees, provided that such improvements are not intend-
ed or offered br sale. II. however, the building or improve-
ment is sold within one year 01 completion, the owner-builder
will have the burden of proving that he did not build or im-
prove for the purpose 01 sale).
I, as owner 01 the property, am exclusively Contracting with licensed contractors In construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply In an owner 01 properly who builds or im' proves thereon. and who contracts for each projects with a I contractor(s) license pursuant to the Contractor's License Law).
I As a homeowner lam improving my home, and the follow- ing Conditions exist: I
I. The work is being performed prior to sale
I have lived in my home for twelve months prior to completion of this work.
I have not claimed this exemption during the last three years.
0 Iam exempt under Sec. . B&P.C. for this reason
I hereby affirm that I have a Certificate of consent to sell-insure, or a certificate of Workers Compensation In-
surance. ore certified copy thereof ISec. 3800. Labor Code) I
POLICY NO. I
COMPANY
Copy is filed with the city
. Certified copy is hereby furnished
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE I
IThis section need not be completed if the permit i in br one hundred dollars ($100) or less)
certily that in the performance of the work for Which
INS permit is issued. I shall not employ any person in any
manner so solo become subject to the Workers' Compen' I
nation Laws of California.
NOTICE TO APPLICANT: If, after making this Certificate I
of Enemption, you should become subject to the Workers
Compensation provisions of the Labor Code, you must
forthwith comply with such provisions or this permit shall I
be deemed revoked,
1 hereby affirm that there in a construction lending I
agency for the performance of the work for which this per. I
mit is issued (Sec. 3097. Civil Cede)
Lender's Nome..,.,,,._________
Lender's Address
T
a
USE BALL POINT PEN ONLY & PRESS HARD APPLICANT TO FILL IN INFORMATION WITHIN SHADED AREA AND DECLARATIONS.
CARLSBAD BUILDING DEPARTMENT APPLICATION & PERMIT 2075 Las Palmas Dr., Carlsbad, CA 92009-1915 (619) 438-1161
.308 ADDRESS AV. STAb, THOMAS BROS NO DATE OF APPLICATION I BUSINESS LICENSE d VALUATION PERMIT NUMBER
2380-Spruce Street 0 i 94,518
CONTRACTORS PHONE a ZONE LOT BLOCK SUBDIVISION-.. ASSESSOR PARCEL NO. CONTRACTOR
. J ,.4-2I€_' OWNE 'S NAME
_ 87-388
OWNERS PHONE
CONTRACTOR'S ADDRESS 49I '''" I STATE LICENSE NO. BUILDING SO. FOOTAGE 72 9 127 2_ 0016 09/02 010. O2B1dp(flt 545.7 OWNER'S MAILING ADDRESS 31-1-1514S_
3 . 57' DESIGNER
______________________________________
DESIGNER'S PHONE
DESCRIPTION' WORK
DESIGNER'S ADDRESS STATE LICENSE NO.
5 ( ' '. F/P FLRELEV.I I NO OCCGP EDU I STORIES
YO
I
NO
CENSUS TRACT PARKING SPACE RES UNITS GRADING PERMIT ISSUED I REDEVELOPMENT I I TYPE 0CC LOAD I FIRE SPR I AREA I I CONST
0 N 0 J YO NO I I - I vjJ NO Not Valid Unless Machine Certified
OTY. PLUMBING PERMIT - ISSUE 7-iQ- OTY. MECHANICAL PERMIT - ISSUE SUMMARY/ACCOUNT NUMBER
EACH FIXTURE TRAP , INSTALL FURN. DUCTS UP TO 100,000 BTU - BUILDING PERMIT 001'810'00'00'8220
EACH BUILDING SEWER . OVER 100.000 BTU SIGN PERMIT 001'810'00'00'8221
- EACH WATER HEATER ANDDR VENT . BOILER/COMPRESSOR UP TO 3 HP PLAN CHECK 001-810-00-00-8891
- EACH GAS SYSTEM 1 104 OUTLETS . - SOIIERICOMPRESSOR 3I5 HP . TOTAL PLUMBING 001'810'00'00-8222 ?
EACH GAS SYSTEM b OR MORE , METAL FIREPLACE ' ELECTRICAL 001-810-00-00-8223
EACH INSTAL., ALTER. REPAIR WATER PIPE z: VENT FAN SINGLE DUCT / .5 MECHANICAL 001'810'00'00-8224
I EACH VACUUM BREAKER ,
c MECH EXHAUST HOOD/DUCTS . MOBILEHOME O01'810'O0'0O'8225
WATER SOFTNER . - RELOCATION OF EA FURNACEIHEATER . SOLAR 001'810'00'00'8226
- EACH ROOF DRAIN (INSIDE) ' , DRYER VENT - STRONG MOTION 880'519'92'33
- - TOTAL MECHANICAL FIRE SPRINKLERS 001-810-00-00-8227
TOIAL PLUMBING I _3 .ô PUBLIC FACILITIES FEE 320'810'00'00-8740
BRIDGE FEE 360-810-00'00'8740
OTY. ELECTRICAL PERMIT - ISSUE OTY. MOBILE HOME SETUP PARK-IN-LIEU (AREA
/ NEW CONST CA AMP SW1 BKR 0 O 0 CAR PORT . TIF 312-810-00-00-8835
I PH 3 PH , AWNING , LA COSTA TIF 311-810-00-00-8835
EXIST BLDG EAAMPISWT'BKR GARAGE FMF
1 PH 3 PH . - . LICENSE TAX 001'810-00'00'8162
REMODEL ALTER PER CIRCUIT . MFF 880-519-92-57
TEMPPOIE 200A MPS
- OVER 200AMPS
TEMP OCCUPANCY 130 DAYS) .
CREDIT DEPOSIT <
- TOTAL ELECTRICAL
I
0r) - TOTAL TOTAL FEES PAYABLE
provisions of this * AN OSHA PERMIT IS REQUIRED FOQ&Avn-.A I HAVE CAREFULLY EXAMINED THE COMPLETED 'APPLlCATtON AND PERMIT" AND DO HEREBY I Expiration. Every permit issued by the Buitdirl.g Official under the
I Code shall expire by limitation and become null and void If the building or work CERTIFY UNDER PENALTY OF PERJURY THAT ALL INFORMATION HEREON INCLUDING THE 50" I authorized by such permit is not commenced within 180 days from the dale of such DEEP AND DEMOLITION OR CONSTRUCTION OF
DECLARATIONS ARE TRUE AND CORRECT AND I FURTHER CERTIFY AND AGREE IF A PERMIT (S permit, or if the building or work authorized by such permit is suspended or STRUCTURES OVER 3 STORIES IN HEIGHT
ISSUED: TO COMPLY WITH ALL CITY. COUNTY AND STATE LAWS GOVERNING BUILDING CON. I abandoned at aaZJi9HLAfter the work is commenced for a period 01180 days STRUCTION. WHETHER SECIFIEO HEREIN OR NOT. I ALSO AGREE TO SAVE INDEMNIFY AND
KEEP HARMLESS THE-CITY OF CARLSBAD AGAINST ALL LIABILITIES. JUDGMENTS. COSTS AND 0
EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE ______ BY P4ONE (1
CONTRACT
APPROV
e
DATE
GRANTING OF THIS PERMIT. i
St
'S - S t •.5 'N - . - .. . INSPECTOR
FIELD INSPECTION RECORD
REQUIRED SPECIAL INSPECTIONS
REQ. IF INSPECTORS INSPECTION CHECKED APPROVAL DATE
___ OILS COMPLIANCE
PRIOR TO
FOUNDATION INSP
STRUCTURAL CONCRETE
OVER 2000 PSI
PRESTRESSED
CONCRETE
POST TENSIONED
CONCRETE
FIELD WELDING
HIGH STRENGTH
BOL'f S
_____ . ) ____
SPECIAL MASONRY
__
- PILES CAISSONS
BUILDING
, TYPE DATE
FOUNDATION
REINFORCED STEEL
MASONRY
GUNITE OR GROUT
SUB FRAME 0 FLOOR 0 CEILING
_
SHEATHING 0 ROOF 0 SHEAR
FRAME ' i'4
EXTERIOR LATH
INSULATION
INTERIOR LATH & DRYWALL
PLUMBING
0 SEWER AND BL/CO 0 PJCO
UNDERGROUND DWASTE DiWATER
TOP OUT !111ASTE E1ATER 0
TUB AND SHOWER PAN i
GAS TEST I
INSPECTORS NOT
WATER HEATER 0 SOLAR WATER
ELECTRICAL
ELECTRIC UNDERGROUND 0 UFFER A -
ROUGH ELECTRIC 1 I . -
ELECTRIC SERVICE 0 TEMPORARY
O BONDING 0 POOL
MECHANICAL
DUCT & PLEM., 0 REF. PIPING
HEAT - AIR COND. SYSTEMS :
VENTILATING SYSTEMS I
I •
CALL FOR FINAL INSPECTION WHEN ALL APPROPRIATE
ITEMS ABOVE HAVE BEEN APPROVED .'. -
FINAL
PLUMBING : - -. •55
ELECTRICAL I
MECHANICAL -
GAS
B
SPECIAL CONDITIONS
UILDING
______ ______ - 5- ---- ... - _5•• 5 - - .5
- 5. . S. •-..-...
DEVELOPMENT PROCESSING SERVICES DIVISION
2075 LAS PALMAS DRIVE
CARLSBAD, CA 92009-4859
(619)438-1161
MISCELLANEOUS FEE RECEIPT
Applicant Please Print And Fill In Shaded Area Only
JOB
ADDRESS PLAN ID NO.
ASSESSOR'S
PARCEL NO.
OWNER
OWNER'S
MAILING ' e23,9j / ADDRESS j — 0017 07/21 0101 05llisc. 258.00
CITY ZIP 92.er ./TEL.?— ?' VALIDATION AREA
CONTRACTOR Ze - 2' /7 0 ESTMATED VALUATION
PLAN CHECK FEE 001-810-00-00-8821
CONTRACTOR'S
MAILING 12 44//e 9 51 ADDRESS .... IF THE APPLICANT TAKES NO ACTION
WITHIN 180 DAYS, PLAN CHECK FEES
WILL BE FORFEITED. CITY 39,%&4' ZIP9?2,001 TEL.g3p_/2o3
STATE BUSINESS
LICENSE NO3 -5 LICENSE NO.
SUBDIVISION LOT(S)
LEGAL DESCRIPTION CHECK IF SUBMITTED:
0 2 ENERGY CALCS
0 21987 ENERGY CALCS
FOR _NON _RESIDENTIAL _BLDGS
DESCRIPTION OF WORK i2i.f 0 2 STRUCTURAL CALCS
4' 0 . 2 SOILS REPORTS
0 2 SELF ADDRESSED ENVELOPES
DATE GIVEN! DATE SENT TO APPLICANT
CONTACT PERSON /fryl /F///74#)( (1,,gj. LA COSTA LETTER
ADDRESS Oj4 A.,,_r, '/ SCHOOL FEE FORM
Ir
AO—A 71 6P7/05 TEL./P CITY, & E CORRECTIONS LIST
CERTIFICATE OF OCCUPANCY
APr3tG)VAT0RE -
/ VATE, '
White - File Yellow - Applicant Pink - Finance Gold - Assessor
FINAL BUILDING INSPECTION
,
PLAN CHECK NUMBER:
87-388
DATE: ___
4-14-88
PROJECT NAME:
2380 Spruce St ' ADDRESS: -
PROJECT NO.: . UNIT NUMBER: . 'PHASE NO.;
tires , '• , TYPE OF UNIT: _____________________________ NUMBER OF UNITS:
,CONTACT PERSON: Joe Moore
CONTACT TELEPHONE 4341203
bldgEengin,pkrn;flre,h20 -
INSPECTE9// DATE
INSPECTED: 2 ~PP APPROVED ,_____ DISAPPROVED
' - DATE •'
BY: . . INSPECTED: ___________ APPROVED' ______ DISAPPROVED
INSPECTED ' DATE -
BY: ______________________ INSPECTED: ___________ APPROVED ______ DISAPPROVED
COMMENTS: '
I
. • • /
- . . .
• • •
Rev. 1186 WHITE Suspense BLUE Water Distrl N Engineering CANARY Utilities PINK Planning GOLD Fire
- -
FINAL BUILDING INSPECTION
7-388 PLAN CHECK NUMBER:
PROJECT NAME:
r . 2380 Spruce St. ADDRESS:
PROJECT NO.: f NIIT NUMBER:
TYPE OF UNIT:
DATE: 4-14-08
NUMBER OF UNITS:
PHASE NO.:
Joe Moore CONTACT PERSON:
434-1203
CONTACT TELEPHONE:
/ bIdg.engln, plan, fire, h2o
BY: - -All DATE
____________ APPROVED ______ DISAPPROVED
INSPECTED DATE
- BY: ________________________ INSPECTED: ____________ APPROVED ______ DISAPPROVED
INSPECTED DATE
BY: _______________________ INSPECTED: APPROVED ______ DISAPPROVED
- COMMENTS:
S.,.-
I.,
r7............•. -
-":
.5;. ••.
-.•• f •S.•5 •••'•
Rev. 1186 WHITE: Suspense BLUE: Water District GREEN: Engineering CAN)ARY: Utilities PINK: Plan ing GOLD: Fire
. 5-
I S..
I
FINAL BUILDING INSPECTION
• 87-388 PLAN CHECK NUMBER: DATE:
PROJECT NAME:
- 2380 Spruce St. ADDRESS
PROJECT NO.. UNIT NUMBER ______________ PHASE NO
tires, ' TYPE OF UNIT: NUMBER OF UNITS:
Joe Moore CONTACT PERSON
434-1203 CONTACT TELEPHONE
- bldg,erigin,plan,flre,h2o
. •.t -. .
INSPECTED,. DATE
BY: ________________________ INSPECTED: ____________ APPROVED ______ DISAPPROVED
INSPECTED :• DATE
BY INSPECTED ____________ APPROVED ______ DISAPPROVED
INSPECTED 1' DATE
BY: INSPECTED: ___________ APPROVED - DISAPPROVED
COMMENTS:
•
Engineering IFIUT. rim. I
Rev. 1186 WHITE REEN Engineering CANARY Utilities PINK Planning GOLD Fire
FINAL BUILDING INSPECTION
07-388 4-14-88 PLAN CHECK NUMBER: _______________________________________ DATE:
PROJECT NAME:
H 380 Spruce St. ADDRESS:
0.
PROJECT NO.: _________________ UNIT NUMBER: _________________ PHASE NO.:
ti res
H TYPE OF UNIT: ___________ NUMBER OF UNITS:
Joe Moore CONTACT PERSON:_____________________________________________________________________
434-1203 CONTACT TELEPHONE_____________________________________________________________________
b1dg,enn,p1an,firh2o
INSPECTED TECTED APPROVED DISAPPROVED
INSPECTED DATE
BY: : INSPECTED: ___________ APPROVED ______ DISAPPROVED
INSPECTED DATE
BY: ______________________ INSPECTED: ___________ APPROVED ______ DISAPPROVED
COMMENTS:
Rev. 1186 WHITE: SUspense BLUE: Water District GREEN:.Englneering CANARY: U:Il Kianning GOLD: Fire
PiflE TREE LUMBER CO.
LI
liv
.00
:ear Sirs,
The 6 x 12 timber supplied by Pine Tree Lumber for Joe Moore
a: 2380 Spruce Street in Carlsbad carries a minimum grade of
i and better.
If there are any questions please feel free to call me at
-5-0411.
1h4ril Yop,
Villiarn Evans
enera1 Sales Manager
'. .NcEASEN OR. ill WEST VISTA WAY 215 E. IVY ST.
92025 VISTA CA. 92083 FALLSROOK CA. 92028
819-724-2153 612-728-6151
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619) 560-1468
DATE: Atjac1- 3/;, I77
JURISDICTION: _____________________________ PLAN CHECKER
FIL
DES IGR
corrected where
the .jurisdicton's r\
AP
PLAN CHECK NO: 7-
PROJECT ADDRESS:
PROJECT NAME: Aid
E] The plans transmitted herewith have bee
necessary and substantially comply with
building codes.
The plans transmitted herewith will substantially comply
with the jurisdiction's building codes when minor deficien-
cies identified are resolved and
checked by building department staff.
D The plans transmitted herewith have significant deficiencies
identified on the .enclosed check list and should be correcte
and resubmitted for a complete recheck. I
E) The check list transmitted herewith is for your informati'n.
The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
EJ The applicant's copy of the check list is enclosed fo/ the
jurisdiction to return to the applicant contact persn.
The applicant's copy of the check list has been se /t to:
Esgil staff did not advise the applicant contIct person that
plan check has been completed.
Esgil staff did advise applicant that the plan check has
been completed. Person contacted:
71)
Date contacted: Telephone #,ytfl,ii I ØFt i
REMARKS 7L /' ------------------ __7__-__--.- ,-,------
7 crocc -ci4,i
By: Enclosures:_____________________ ESGIL CORPORATION
/y
-
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619) 560-1468
DATE: flLu!,Li.,r ,ô. ,'9,'7
JURISDICTION: CITY 69 c7 AR156141)
PLAN CHECK NO: R'7 - £'
PROJECT ADDRESS: ,-9i Pcuc .Si
PROJECT NAME: t)t),r1O0
TIPLAN CHECKER
OFILE COPY o UPS
ODES IGNER
D The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
fl The plans transmitted herewith will substantially comply
with the jurisdiction's building codes when minor deficien-
cies identified are resolved and
checked by building department staff.
D The plans transmitted herewith have' significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
pj The check list transmitted herewith is for your information.
The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
DAM) mni,v Pft (2 OY ci
DJ'6i) (1) 9,q //)l
J Esgil staff didnot advise the applicant contact person that
plan check has been completed.
Esgil staff did advise applicant that the plan chek. has,
been completed. Person contacted: Joc_mrn, _(1t(Lfr,'1J
Date contacted: Telephone
REMARKS:
By: Wdi—kti Enclosures: WO.1L Aierr?.,V
ESGIL CORPORATIO9,
Citp of CarIbab
th
JURISDICTION: Date -.?/)-.'7
PROJECT ADDRESS: ,?2,')_SPRfteg_i
TO: flj I y'f)p. ol d '/
P,. (UV 1
Sfln/4o. C-A ?/O'
PLAN CORRECTIONSHEET
Plane Check No. 7-3RRfl
Date plans received by the jurisdiction
Date plans received by plan checker 2-1 -?2
SEOUO
Date imib&ea plan check completed 0-P7'
By E/LPI) LAJPL?(p
FOREWORD: PLEASE READ
Plan check is limited to technical requirements
contained in the Uniform Building Cede, Uniform
Plumbing Code, Uniform Mechanical Code, National
Electrical Code and state laws regulating energy
conservation, noise attenuation and access for
the handicapped. The plan check is based on
regulations enforced by the Building Inspection
Department. You may have other corrections
based on laws and ordinances enforced by the
Planning Department, Engineering Department or
other departments.
The items circled below need clarification,
modification or change. All circled items have
to be satisfied before the plans will be in
conformance with the cited codes and regulations.
Per Sec. 303 (c), of the Uniform Building Code,
the approval of the plans does not permit the
violation or any state, county or city law.
A. PLANS
Please make all corrections on the original
tracings and submit two new sets of prints,
and any original plan sets that may have
been returned to you by the jurisdiction,
to:Ecc1./ 'ir ' ;..:?( P/90&
To facilitate rechecking, please identify,
next to each circled item, the sheet of
the plans upon which each correction on
this sheet has been made and return this
check sheet with the revised plans.
3: •
________ )f.I (' FS
T? A15 '1!)TPlPLL)
1-r\ , ,. r . :, •. i.-- • i I
? i 'c': ;j)'i•,;.
e. PRO)ii7( Y(.'?. )7 LiJ Ti)
I -r, ('/,JSel iipA1-mrs)-r U)
AfiH.
,Q.f Aki- r) PLq*) iHir cPc,)PH
A. A)Or s) P, , .c, n i /4.•IT(
P
____
j7V 4i11
c9D A.-rg 1H)'1 .HpbJ&1U1,
E),/a'pRc A ..sFeT9 62rn
iw PP 'J u , f <i7'. /Jo re 1 h(rT
rugKf4PF1_4ip/),
Ain-r O) P' T4.4T
jp1q j, flp 1) PP I L _____
LFç TMAP
sd)l jPJitY)c/LpcI('. JIJ<'1)FQU)ó L/j/P
cCPtL) A)FLC. '.s1 e40'5
A-r irPPML
.3S crn?. (rl'#.)c — pp
.4
U. IPaular HE/hill .
J.de,T 04 VTh4',JP_V
PVIJ, OP (!i41(c1 JOAT''IIii
-7H.r_WP1 e,_Ui'_flD _-
THP_/_/P_fIin,r_-
______
)p'.).
HOh' !••J.•i•P. PPorcrir,,J mi
i_Pf",r!J(Lth_p_.inIr.
911.1 SE 0-&reie ECT//AJ #35.
7'i. I pp-nu :of duPJiYT SOILS RrP1Pr
)EiFYI*)( A, I t 1A t- Y 0 gi 0rIlJ7.S.
32. ..SiJppj"Ifr OP w1At LS tUgr rt
Uflt IT?JT) ()Ae&JT PPoPfRTY
CLLA1.1 NO Lift PF+TH r(ç7p'r7
1o~ cMon. -r,.,p P!#11! £iJ/m)%''•Al
JfJ4 /)1)1.f' /JA!' i,)1. J'!J. 4m234' '1 ',-)/1-#;$;,i'
ilL Iorr Pi-ro e,'m OA) P!
.. L-Upil ol
W.
OI72Ot)?7
J&L Y)P(k' ir yr . trnn - FRivv"'3 Pi ti c1 ALL) s vi I 'f-OC RX "
PI-E.3E CMR..iPy. 4L-O oor- PR_#?rYJu)6 .sows OEk
P'i(1 EL F _DthRiD, LSa iT aPHJ. IF $&PPR7 P
1PRS IF AiYT 1J I) RE wc Root ,',viM PLJ.
Jur,p?,A)& HPPI/)PE. '12t! nnr, /,° ,jig)rô.J 41
r)f) -,srFiF. _iuit: i;• jir,p;,s_oe
- rwP rpF)rH OOoR tJ/.c,nF LJ1f _ '-• -''
I APIJ67 kriAt Fiom THF 12 PP'i L'(I( Ac LJ-'.. ,4 h4WF&. f)i -;...
-
PPe,P 1i)O,Jt ' _ L)1fl ./A'. /)t4 d_)<A?LE 1JJL.L. LlAJc
-
- LOtJi. LUEL1 PL#911S £ftOi) c)1 OF 3.L4J W/tIcH _J/ _ftE..Lü/L_
- rYPe 9600i 1--0k- (/- KFII/',e ('/tec. .1 Pu5. e) 6//en4e. LW
- 1T PLbo1. Pyws ci.#•,J i.' c!ALC, RE1'L'e ,q OFhEfrJ. IiJiL(.
- , a44LCs. Co JioT ADOIZe-16 AQ f&tLtt)' OP 1168- bPLA)FIUC,S
l)k)LW fPRS IL)E4 OPAPfl Ci.tiTL0 /) EPPecr/U(
-
J3 S/mw cn) P4'6 eYrFMr) " I'UE (-OE OL) ,LL P1EE.1
- DR. PR'uir c?,EA)E. jUOr#
J3L. AlQTr 1)ti PL$) cyrgeiip. Ar)e P ,ioôO m t3e U -o A-T Fe-iD
- Cc
J 3/#oc SuPPoP-r
.J31. SiiôJ 512E OP EY/ST/iC)(7 FAu, 1-0 .J'Lsf/f' J-/&#T1iOf,. I /riA)C fl.lis
- ftJL&) i4I2S.
morr a,J Pt_)ql) Se PouWe'O
/1/ Roar pp-r/o#is e )-1rn1Th0 rô llo% Dc PLOOeE ij'J tAlJIJr.
1-14/c APP/ Per c o,ur i, 7W e i4T2Vif'OJ. T1tE AOz)iiiJ 1.5 /399 0 Y
PL°sic SM.ok) a7q4l &U3 rHe tAziMfi-? Atôii Poos Z
F1J1 R)fl' 4- IjJlI)(/I: R Y}1STE. i4DP.l7' REUILCf (rL.Pi1i2)& n/a P24niinr
eAln-121,Y Fi-LCcI ALSO mwer ,).J ,DiUJ 7WE
T/-!E 1A1LAzk MiJ.
fg04- 7/. IP FAJeEc-c' a14?rs. PP_ow r.q. nnrE ALL CAI,-e,.OAJ PLAit)'
I93.- fviiPiQiit)r y'1AAJppr!)rY e
J14 i.4)JPFQ'h itJ ft?.M/Y'. jiJ.c-. t't thJOT i DUcT1p rPe.
). r,, ?e'yn' (E/!)gfl p np,c ti'E SOi ±P€7• r,
if Th'e ,4Re ,qa. UE1IIJS &IL EiIFJ WU'E'
AT 5)-,ve
-rtM/J YILf.
E FOLLOWING NOTE SPECIFYING MANDATORY RWUIRITS 33OULD BE n[CORPORAXED ON PLAN SMM, OR
CONTAINID Wiiuiz .703 SPECIFICATION DOQIS.
MANDATORY ENG1 CONSERVATION K J1J2!&'ITS OF THE STAIX OF CALI7ORNIA
(1) All heating, ventilating, air conditioning, and water heating equipment shall meet all of the
requirements of the Appliance Efficiency Standards and shall be certified by the California Energy
Commission.
(2) A two stage thermostat, which controls the supplementary heat on its second stage, shall be
provided for heat pumps.
(3) Thermostats shall be equipped with an automatic setback, which the building occupant can program to
automatically set back the thermostat twice in hi hours..
(4) Equipment which requires preventive maintenance to maintain efficient operation shall be furnished
with complete necessary maintenance information.
(5) All gas-fired fan type central furnaces, gas-fired fan type wall furnaces, and cooking appliances
shall be equipped with an intermittent ignition device.
(6) All fan systems exhausting air to the outside shall be provided with backdraft dampers.
(7) All transverse duct, plenum, and fitting joints shall be sealed with pressure sensitive tape or
mastic to prevent air loss and shall be insulated to conform to the provisions of Section 1005 of
the UMC, 1982 Edition.
(8) A vapor barrier is required in climate zone 1, 14, and 16.
(9) All manufactured windows and sliding glass doors shall meet the 1972 ANSI air infiltration
standards and'shall be certified and labeled.
(10) All swinging doors and windows leading to unconditioned areas shall be fully weather-stripped.
(U) Storage type water heaters and storage and backup tanks for solar systems shall be externally
wrapped with R-12 insulation or greater.
The five feet of pipe closest to the water heater, if outside conditioned space, shall be insulated
with a minimum of R-3. Steam and steam condensation return piping and recirculating hot water
piping outside the building envelope shall be insulated in accordance with 120-1406(d).
Lamps used in luminaries for general lighting in kitchens and bathrooms shall, have an efficiency of
not less than 25 lumens per watt.
Showerheads and faucets shall be equipped with flow restrictors as outlined in the appliance
efficiency standards and shall be certified to the Energy Commission.
Masonry and factory-built fireplaces on exterior walls, shall be equipped with tight-fitting
closeable metal or glass doors covering the entire opening of the firebox; a combustion air intake
equipped with a readily accessible, operable, and tight fitting damper to draw air from the outside
of the building; and a tight fitting flue damper with a readily accessible control.
Insulation used shall comply with California Quality Standards.
(11) The insulation, installer shall post. a signed certificate. . .Section. 276:. Insulation Certificate
(All Occupancies). After installing insulation, the installer shall post in a conspicuous location
in the building a certificate signed by the installer and the builder stating that the installation
conforms the requirements of Title 24, Part 2, Chapter 2-53, and that the materials installed
conform with the requirements of Title 20, Chapter 2, Subchapter I., Article 3. The certificate
shall state the manufacturer's name and material identification, the installed "R" value, and (in
applications of loose fill insulation) the minimum installed weight per square foot consistent with
the manufacturer's labeled density for the desired "R" value.
(18) For infiltration control all openings and penetrations must be caulked and sealed, such as around
windows, at sole plates, and openings for utility pipes and wires.
Form ECH 3/5/86
-4;
ESGIL CORPORATION
. 9320 CHESAPEAKE DR.. SUITE 208
SAN DIEGO, CA 92123
(619)560.1468
DATE: a. l97 DAPPLIc
URISDI
JURISDICTION: CITY OF CARLSBAD DPLAN CHEC
0 FILE COPY
PLAN CHECK NO: 7- 3 : 0 UPS
M DESIGNER
PROJECT ADDRESS:
PROJECT NAME: /frj nor' .
The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
D with the jurisdiction's building codes when. minor deficien-
cies identified are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies
0 identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is the jurisdiction's
copy for your information. The plans are being held at
Esgil Corp. until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
MA/ n'I,MJAJli( Pc. 13&' 3i1c.7! S&N bs. PLHC,AhI'? 923
Esgil staff did not advise the applicant contact person that
plan check has been completed.
Esgil staff did advise applicant that the plan check has
been completed. Person c,ontacted: CBj rcrj
Date- Telephone #_44'- 1Z03
REMARKS:
BY: Af ENCL:_______________
ESGIL TIN
7//r7
PLAN CHECK NO. -
JUISDIICII: CM OF CARLSBAD
TO: V/7& iVIi/./iV
$4iJ b&co C/11,D3
TPBONE NO.
PLAN Q)RR1ON r
SIN.E FkXfl.Y AND DUPLEX 1IELLIWS
Date plans received by jurisdiction:
Date plans received by Esgil Corporation:
Date initial plan check completed:
I - ) By: 64,ecl tJef
Applicant contact person:
\'& Telephone: 4d/2o
Plan check is limited to technical requirements
contained in the Uniform Building Code, Uniform
Plumbing Code, Uniform Mechanical Code,
National Electrical Code and state laws
regulating energy conservation, noise
attenuation and access for the handicapped.
The plan check is based on regulations enforced
by the Building Inspection Department. You may
have other corrections based on laws and
ordinances enforced by the Planning Department,
Engineering Department or other departments.
1982 USC (off. 7/1/85)
1985 UPC (eff. 11/12/86)
1984 NEC (eff. 10/1/85)
1985 UMC (eff. 11/12/86)
The above regulations apply to residential
construction.
The circled items need clarification,
modification or change. All items have to be
satisfied before the plans will be in
conformance with the cited codes and
regulations. Per Sec. 303 (c), 1982 Uniform
Building Code, the approval of the plans does
not permit the violation of any state, county
or city law.
To sneed um the recheck process • note on this
list (or a copy) where each correction item has
been addressed i.e.. plan sheet, specification.
etc. Be sure to enclose the marked up list
when you submit the revised plans.
NDIE: PAGE NMMZRS ARE NOT DI SEQUEOCK AS PAGES RAVDI NO 1G 1DIG (SBEl(IONS WERE DELZMD.
Carlsbad List 10, Single Family Dwelling and Duplex With All. Supplements
1
3/25/86
A. PLANS
1. Please make all corrections on the original
acings and submit two new sets of prints, and
any original plan sets that may have been
returned to you by the jurisdiction, to:
Esgil Corporation, 9320 Chesapeake Drive,
Suite #208, San Diego, California 92123,
(619) 560-1468.
,2'. Please make all corrections on the original
tracings and submit two new sets of prints, and
any original plan sets that may have been
returned to you by the jurisdiction, to:
1.
The jurisdiction's building department.
,X(' Indicate on the Title Sheet of the plans,
the name of the legal owner and name of person
responsible for the preparation of the plans.
Section 302 (a) 7.
4e Plans, specifications and calculations shall
signed by a California state licensed
engineer or architect. (California Business and
Professions Code).
() Specify on the Title Sheet of the plans the
gross floor area of each element of this project
including dwelling, garage, carport, patio, deck
and balcony. Section 302 (c).
QQ6. Provide a statement on the Title Sheet of
6 plans that this project shall comply with
Title 24 and 1982 UBC, UMC, and UPC and 1984
NEC.
I.
Submit fully dimensioned plot plan drawn to
scale showing location, size, and use of all
existing and proposed structures on the lot.
Identify propeity lines and show lot dimensions
and all easements. Show location of all cut or
fill slopes and approximate finish floor
elevations for all structures and show
elevations at all lot corners.
Section 302 (c).
2
3/25/86
Indicate distance from center line of street
or alley to property line and distance from
property lines to proposed building.
Section 302 (c).
B. FIRE PIyizLON.
Walls closer than 3 feet to property lines
'shall be one-hour rated construction, have no
openings, and shall have 30 inch parapets when
the building floor area exceeds 1,000 square
feet on any floor.
(Table 5. A. Section 1709 (a)).
10. Projections, including eaves, may not
extend morn than 12 inches into the 3 foot
setback from the property line. Eaves over
required windows shall be not less than 30
inches from the side and rear property lines.
Section 1710 and Section 504 (a) and (b). e.4bvj oitSiJ ot) Si1E 'L4tJ
t- Plastic skylights shall not be installed
thin 8' of an exterior wall located where
openings in such exterior wall are prohibited or
required. to be protected.
Section 5207 (a) 7.
Q--oehour
Projections, including eaves, shall be
fire-resistive construction, heavy
timber or of noncombustible material if they
project into the 3' setback area from the
property line. Section 1710.
13 Show location of permanently wired smoke
ete
.
ctor, centrally located in corridor leading
to sleeping rooms or above stair if sleeping
rooms are on upper level. Section 1210.
t
A smoke detector shall be installed in the
ement of dwelling units having a stairway
which opens from the basement into the dwelling.
Such detector shall be connected to a sounding
device or other detector to provide an alarm
which will be audible in the sleeping area.
Section 1210.
C. FJM SIZ, LI. V1UATIOII AND (.AZING
Co- 'Habitable rooms, other than kitchens, shall
!contain at least 70 square feet of floor area.
Section 1207 (b).
I Window area must be at least 1/10 of the
oor area and a minimum of 10 square feet per
Section 1205 (a). Appears to be deficient in
3ñ. Openable window area in habitable rooms
must be 1/20 of the floor area and a minimum of
5 square feet. In bathrooms, laundry rooms and
similar rooms 1/20 of area is required and
minimum is 1.5 sq. ft. (Section 1205(a)).
l,. At least 1/2 of the common wall must be
open and have an opening not less than 25 sq.
ft. if light and ventilation is being supplied
from an adjacent room. Section 1205 (a).
. Required windows shall not open into a
roofed porch unless the ceiling is at least 7
feet and the longer side is at least 65% open.
Section 1205 (a).
() Provide mechanical ventilation capable of
providing five air changes per hour in
bathrooms, water closet compartments, laundry
rooms and similar rooms if required openable
windows are not provided. Section 1205 (a).
311. No habitable room, other than a kitchen,
shall be less than 710" in any dimension.
Section 1207 (c).
2. Show that ceiling height for habitable
rooms is a minimum of 716". Section 1207 (a).
Dimension on the plans, the 30" clear width
.for water closet compartments and 24" clearance
in front of water closet.
Section 511 (a).
Qzar
Specify safety glazing for glazing in
dous locations such as glass doors, glazing,
adjacent to such doors and glazing adjacent to
walking surfaces. Section 5406.
26. Glazing, in the sane wall plane as a door,
t be safety glazing if within 12" of the door
and less than 60" above the walking surface,
unless the glazing is leaded on faceted glass.
Section 5406 (d) 7.
0
27.27. Glazing in shower and tub enclosures shall
tempered, laminated or approved plastic
(including windows within 5 feet of tub or
shower floor). Section 5406 (d) 5.
8. Sleeping rooms shall have a window, or
exterior door for emergency exit. . Sill height
shall not exceed 44" above the floor. The
window must have an openable area of at least
5.7 square feet with the minimum openable width
20" and the minimum openable height 24".
Section 1204.
2,y
. A mezzanine is an intermediate floor and
not have a floor area exceeding 33 1/3.
percent of the total floor area in the room
below. The mezzanine floor must have a clear
height of 7 feet, above and below, and must have
the long side open to the room below except for
posts and protective walls or railings not
exceeding 42" in height. Section 1716.
0. The loft you show does not comply as a
mezzanine floor and is, by Uniform Building Code
definition, a story. Section 1716.
3. Show ceiling height for laundry rooms,
hallways, corridors, and bathrooms is a minimum
of 71 0". Section 1207 (a).
cAJrgnt.. - 'thi Si; !r/b or W!NDW CW&)Q Po- Z-
3
3/25/86
D. XKUS. SrAIRWAYS. AND RAUMIGS
3)L. Floors above the second story shall.have
hot less than 2 exits. Section 3303 (a).
4. Required exit doorways shall be not less
'than 36" in width and not less than 61811 in
height, and shall be capable of opening at least
90 degrees. Section 3304 (e).
Provide 36" high protective railing for
rches, balconies., and open sides of stair
landings. Openings between railings shall be
less than 6". Section 1711.5lh
Show how guardrail connection details are
equate to support 20 pounds per lineal foot at
a right angle to the top rail. Table 23-B.
Q)tion
Provide stairway and landing details.
3306 (b) & (c).
Maximum rise 8" and minimum run is
9".
Minimum headroom is 61 6".
Minimum width is 30".
D36. fl handrails per Section 3306 (j), shall
isfy the following:
t. Provide handrail for stairways with 4
or more risers.
() Handrail shall be 30" to 34" above the
nosing of treads.
() The handgrip portion of handrail shall
be not less than 1 1/4" nor more than
2" in cross-sectional dimension.
(See-attached)
4
3/25/86
4. Every stairway landing shall have a
dimension, measured in the direction of travel,
at least equal to the stairway width.
Section 3306 (g)
A door may open over a stairway landing
provided.the door, in any position, does not
reduce the clear area of the landing in the
direction of stairway travel, to less than
one-half the required width of the stairway.
Section 3306 (g).
9. A door may open inward at the top step of a
stairway provided the top step is not more than
7 1/2" lower than the floor level.
Section 3304 (h).
4,4. Provide details of winding stairway
éomplying with Section 3306 (d):
Minimum tread is .6 inches at any point
and minimum 9 inches at a point 12
inches from where the treads are
narrowest.
Maximum rise is 8 inches.
C. Minimum width is 30 inches.
4. Provide spiral stairway details, per
ection 3306 (f):
Minimum run is 7 1/2 inches measured
at a point 12 inches from where the
treads are the narrowest.
Maximum rise is 9 1/2 inches.
C. Minimum headroom is 6 feet 6 inches.
12. Spiral stairways may not be used for
squired exits when the area served is greater A
thai 400 sq. ft. Section 3306 (f).
Spiral stairways must have a clear walking
space of 26 inches between the column and
handrail, show dimension. Section 3306 (f).
Provide I.C.-B.O. Research Report and Number
tor metal stairway, or submit plans and
calculations and approved fabricator registered
with the building department or note that the
stairway fabrication shall be done under special
inspection per the approved fabrication plans.
Section 306 (a) 4B and Section 306 (f).
4- In buildings over 2 stories in height,
provide 3/4 hour fire-rated assemblies for all
openings in the exterior wail below or within 10
feet horizontally of an exterior stairway. An
exit balcony with 2 separated stairways is
exempt. Section 3306 (1).
t6
,
_ Exterior stairways shall not project into
3 foot setback from the property lines.
Section 3306 (n).
The walls and soffits of the enclosed
t*s-able space under interior stairs shall be
protected on the enclosed side as required for
one-hour fire-resistive construction.
Section 3306 (m).
E. RODONG
4. Specify roof slope.
t Roof slope is not adequate for roof type
ecified. Table 32-B; Section 3203 (h).
-P
Specify roof material and application.
Pter 32. -
11. Specify I.C.B.0. or U.L. approval number
for roof materials not covered in U.B.C., e.g.,
title, etc., Section 107.
5
3/25/86
The maximum slope for a fire retardant
built-up roof, with rock or gravel surfacing, is
3 inches in 12 inches, Section 3203 (e) 2.
5/i. The minimum slope for a fire retardant
built-up roof, with cap sheet surfacing, is 1/2
inch in 12 inches. Section 3203 (e) 3.
Specify minimum 1/4 inch per foot roof •
slope for drainage or design to support
accumulated water. Section 3207 (a), Section
2305 (f) and Section 2511 (d) 6.
t
t
Show roof drains and overflows.
ec-tion 3207.
Provide skylight details to show compliance
th Sections 3401 and 5207 or provide I.C.B.0.
approval number.
L
Plastic skylight must be separated from
other by at least 4 feet.
Section 5201 (a) 6.
5 Show attic ventilation. Minimum vent area
1/150 of attic area or 1/300 of attic area if
at least 50% of the required vent is at least 3
feet above eave vents or cornice vents. Show
required area and area provided.
Section 3205 (c).
F. MASONRY
tot. Provide fireplace construction details or
e construction to be per attached fireplace
standard drawing. Chapter 37.
reismic
Show veneer support and connections in
Zones 3 and 4, comply with Section 3002,
Li, 5, 6, and Section 2515 (a) regarding ties and
#9 wire in horizontal joints or show
construction to be per attached sheets
30-1 or 30-2.
61. Show height and construction details of all
onry walls. Chapter 24. it, f'(t(1 FI.cO& LocY.)
Note that cleanOut openings shall be
,rovided at the bottom of all cells to be grout
filled over 4' in a single pour. Cleanout shall
be sealed before grouting, after inspection.
Section 2414 (a) S.
Show floor and roof connections to masonry
halls. Connection shall resist 200 pounds per
lineal foot or the actual design load; whichever
is greater. Cross grain tension or bending in
wood ledgers is not permitted.
Section 2312 -(j) 3. A.
Provide details for damp proofing the
foundation walls, below finish grade, where
useable space exists on the interior side of the
walls. Section 1707 (d).
Show a minimum 2" air space and flashing
fr
etween planter and building walls.
Section 2516 (c) 7.
G. GARAGE AND CARPORTS ee
Garage requires one-hour fire protection on
garage side of walls and ceiling common to
the. dwelling. Table 5. B. Section 503 (d)..jiij&. E416-AW.
ece
All elements Supporting floor above garage,
luding walls supporting floor joists, to have
one-hour fire-resistive protection on the garage
side. Section 503 (a).
t Show 1 3/8" solid core self-closing door
or-,openings between garage and dwelling.
Section 503 (d).
. Garages are not permitted to open into a
room used for sleeping purposes. Section 1104.
71. Openings between carport and residence
t'equire self-closing doors and stationary
windows. Section 1214.
71. Show garage framing section, size of header
er garage opening, lateral cross bracing at
plate line, method of bracing garage front, and
holddowns if required. Chapter 23. 11Ytu( L.
CaAIZIYA
NOTE: Maximum shear panel ratio of height to
width is 3-1/2 to 1. Table 25-I.
Doors may open into the garage only if the
floor or landing in the garage is not more than
1/2" lower than the door threshold.
Section 3304 (h).
Provide an 18" raised platform for any PAU,
?ater heater, or other device in the garage,
which may generate a flame or spark, IJMC Section
508, UPC Section 1310 (a).
H. PJNDA1I0N xiixai1
Q. Per soils report, note on the plan the
s us classification, whether or not the soil is
expansive, and note the allowable bearing value.
Section 2905 (c).Jç -m ie-i bP L''r - 6Wbi SiE Of: ALL Tthflt(0
7,. The foundation plan does not comply with
the soil report recommendation for this project.
Please review the report and modify design,
notes and details as required to show
compliance.
7. Provide notes on the foundation plan
1isting the soils report recommendations for
foundations, slab and building pad preparation.
6
3/25/86
7/. The soils report recommends excavations be
1 reviewed by soils engineer. Note on the
foundation plan that "Prior to the Contractor
requesting a Building Department Foundation
Inspection, the soils engineer shall advise the
building official in writing that:
the building pad was prepared in
accordance with the soils report;
the utility trenches have been
properly backfilled .and compacted,
and;.
the foundation excavations, formings
and reinforcements comply with the
soils report and approved plan".
78. Show height of all foundation walls.
pter 23.
Qbw
Show height of retained earth on all
ndation walls. Chapter 23. 5 jS
0. If cut or fill slopes exist, show distance
of foundation to edge of cut or fill slopes and
show steepness and heights of cuts and fills.
Chapter 29.
lL. Note on plans that wood shall be 6"
iinimum above finish grade.
Section 2516 (c) 7.
82.. Note on plans that surface water will drain
ay from building and show drainage pattern and
key elevations.. Section 2905 (f).
() Dimension foundation per U.B.C. Table 29A:
Floors
Supported* Stemwall Width Depth
1 6" 12" 12"
2 8" 15" 18"
3 1011 '18" 24"
*Foundations may support a roof in addition to
the floors. Where only a roof is supported, use
foundation for one floor.
)t VThh)1%VItJ Vf UNLE PcQLD) 611 SOILS EQT
7
3/25/86
41.. Show foundation sills to be pressure
k.reated, or equal. Section 2516 (c) 3.
'5. Show foundation bolt size and spacing.
ection 2907 (e).
8fr. Specify size, I.C.B.0. number and
manufacturer of power driven pins. Show edge
and end distance and spacing.
Section 306 (f).
8/1. If required by structural calculations,
show size, imbedment and location of hold down
anchors on foundation plan. Section 2312 (f).
I. If hold downs are required.by calculations,
note on plan that hold down anchors must be tied
in place prior to foundation inspection.
Section 305 (e) 2.
() Show adequate footings under all bearing
walls and shear walls. Section 2907 (b).
Show on the elevations, stepped footings
or slopes steeper than 1:10.
Section 2907 (c).
t Show minimum 18" clearance from grade to
ot-tom of floor joists and minimum 12"
clearance to bottom of girders.
Section 2516 (c).
() Show pier size, spacing and depth into
undisturbed soil. Table 29-A. AQ 'D3t rr&,S !.
Qoi? 6t4tu 5IiES .o
3. Show minimum underfloor access of 18" x
24". Section 2516 (c).
9. Show minimum underfloor ventilation equal
to 1 sq. ft. for each 150 sq. ft. of underfloor
area. Openings shall be as close to corners as
practicable and shall provide cross ventilation
on at least two approximately opposite sides.
Section 2516 (c).
Specify that posts embedded in concrete
shall be pressure treated per UBC Std. No. 25-
12. Section 2516 (c).
I. FRAPG
96. Show wall bracing. Every exterior wood
stud wall and main cross partition shall be
braced at each end at least every 25 feet of
length with 1 x4 diagonal let-in braces or
equivalent. Section 2517 (g) 3.
4. Note cross bridging or blocking. Floor
joists and rafters 12" or more in depth shall be
supported laterally by bridging at intervals not
exceeding 8 feet, unless both edges are held in
line. Sec. 2506 (g).
Show blocking at ends and at supports of
'floor joists, and for rafters at exterior walls.
Section 2517 (d) 3.
9,4. Show solid blocking at ridge line and at
exterior walls on trussed roofs.
Section 2506 (g), Section 2517 (h).
00. Show double joists. Floor joists shall be
doubled under bearing partitions running
parallel with the.joists. Section 2517 (d) 5.
11. Bearing partitions, perpendicular to
j.bists, shall not be offset from supporting
girders, beams, walls or partitions, more than
the depth of the joist. Section 2517 (d) 5.
l)h. Show rafter ties. Rafter ties shall be
spaced not more than 4 feet on center and be
just above the ceiling joists, where rafters and
ceiling joists are not parallel.
Section 2517 (h) 4.
I,63. Show rafter purlin braàes to be not less
than 45 degrees to the horizontal.
Section 2517 (h) 5.
8
3/25/86
1/4. Show 1/2" minimum clearance between top
plate of interior partitions and bottom chord of
trusses. (To ensure loading will be as
designed).
105 Show double top plate with minimum 48"
p splice. Section 2517 (g) 2.
106 Show nailing will be in compliance with
le 25-Q.
l?%. Show or note fire stops at the following
locations per Section 2516 (f):
in concealed spaces of stud walls and
partitions, including furred spaces,
at the ceiling and floor levels and at
10 foot intervals along the length of
the wall.
at all interconnections between
concealed vertical and horizontal
spaces such as occur at soffits, drop
ceilings and cove ceilings;
in concealed spaces between stair
stringers at the top and bottom of the
run and between studs along and in
line with the run of stairs if the
walls under the stairs are unfinished;
and
d. in openings around vents, pipes,
ducts, chimneys, fireplaces and
similar openings which afford a
passage for fire at ceiling and floor
levels, with noncombustible
materials.
5ob
Show stud size and spacing. Maximum
wable stud heights; Bearing wall: 2 x 4 and
2 x 6 max. 101; Non-bearing: 2 x 4 max. 141, 2
x 6 max. 201. Table-25-R-3.
lJ'9. Studs supporting two floors, a roof and
ceiling must be 3 x 4 or 2 x 6 at 16" o.c.
Table 25-R-3.
1. Note an A.I.T.C. Certificate of Compliance
for glued laminated wood members shall be given
to the building inspector prior to erection.
Section 306 M.
Oting
Detail all post to beam and post to
connections and reference the detail to
the plan. Section 2516 (m).
1. Detail shear transfer connections,
including roof and floor diaphragms, to shear
walls. Section 2513.
US=
Specify nail size and spacing for all
walls, floor and roof diaphragms.
Indicate required blocking. Maintain maximum
diaphragm dimension ratios. (Tables 25 I, 3, K)
and Section 4713 (d).ALcvJb'oiJTh WPu....
1,44. Show 3" x 4" or 2" x 6" studs in first
story of three story building. Table 25-R-3.
1/5. Provide truss details and truss
calculations for this project.
121 Show on the plans all structural
uirements developed in the structural
calculations. 5EC It 170
eonr
Columns and posts located on concrete or
y floors or decks exposed to the, weather
or to water splash or in basements and which
support permanent structures shall be supported
by concrete piers or metal pedestals projecting
above floors unless approved wood of natural'
resistance to decay or treated wood-is used.
Section 2516 (c) 4. .
Roject
Individual concrete or masonry piers shall
at least 8 inches above exposed ground
unless the columns or posts which they support
are of approved wood of natural resistance to
decay or treated .wood is used.
Section 2516 (c) 4.
414. Show location of attic access with minimum
size 22" x 30". Section 3205.
15. Show draft separation for attic areas
between units in a duplex... Section 2516 (f).
116 Provide roof framing plan and floor
aming plan. Section 302 (a) 7. -
M Wpener tti. $Wia (kL,o ivaJ€. IJIOtr 1H Em. 1. Provide framing sections through
6. Wood stud bearing walls, .with studs at 24"
o.c., require 3 en.. 2 x 4 or 2 ea. 2 x 6 or 2
ea.• 3 x 4 top plates if supporting either floor
members or roof trusses that are spaced more
than 16" o.c. and do not bear within 5" of the
supporting stud. Section 2517 (g) 2.
Section 320 (a) 7.
4 R
118 Specify all header sizes for opening over
. Section 2517 (a) 5. e ivui ,.cw
DI\h1JL /L.IJl&3b %<I)4Y
19. Provide 'calculations for main vertical and
Worizontal framing members and post footings.
Section 302 (a) 7.
P120 29 Provide calculations for lateral loads,
shear panels, shear transfer. and related.
Section 302 (9) 7. & 5cuTtA %uP.LL -z"O ccc. -
cL&
9
3/25/86
1/7. Specify plywood grade and panel
identification index. Table 25-N.
18. When roof pitch is less than 3:12, design
ridge as a beam. Section 2517 (h).
12fr. If foundation cripple wall studs are less
than 14" framing shall be solid blocking.
Section 2517 (g) 4.
i,Io. Cripple wall studs exceeding 4 feet in
height shall be 3 inch by 4 inch or 2 inches by
6 inches when supporting 2 stories.
Section 2517 (g) 4.
20ther
Show plywood sheathing over exposed eaves,
weather exposed areas, is exterior
grade. Section 2516 (g) 3.
1/2. Show a weep screed at the foundation plate
,uin e on all exterior and stud walls to be
stuccoed. Section 4706 (e).
1il3. Show corridor width to be minimum 36".
Section 3305 (b).
Specify truss layout for 30" x 30" attic
access.
at-one
Ridges, hips, and valleys shall be at
size larger than supported rafters.
Section 2517 (h)
1/6. In open beam construction, provide strap
ties across the beams at the ridge, support.
Section 2501 (b).
J. MANICAL
.Ail heating, ventilating, and cooling systems
and appliances shall comply with the Uniform
Mechanical Code.
5ti
Show the _size, location and type of all
ng and cooling appliances or systems.
1. Show source of combustion air to furnace,
per Chapter 6, UMC.
(i) Every dwelling unit shall be provided with
heating facilities capable of maintaining a room
temperature of 70 degrees F. at 3 feet above the
floor in all habitable rooms. Show basis for
,conpliance. UBC, Section 1211.AOQg -,
10
3/25/86
"Yo. Show minimum 30" deep unobstructed working
space in front of furnace. Section 505,-UMC.
4 Note on plans, clearances to be per
ufacturerls*listinj. Section 504, UMC.
Furnace shall not be installed, under any
sfairway. Section 704, UMC.
173. Furnace shall'not be installed in any
bedroom, bathroom or in a closet or confined
space with access only through such room, unless
specified as direct vent appliance, enclosed
furnace or electric heating appliance.
Section 704, UMC.
194. Show I.C.B.0. approval number for prefab
fireplace.
15. Show access to the attic or underfloor
f'urnace to be minimum 30 inches by 30 inches.
Section 708 & 709 UMC.
!46. Note that passageway to the' attic furnace
shall be unobstructed. and have continuous solid
flooring not less than 24 inches wide.
Section 708, UMC.
]47. Show permanent electrical outlet and
fighting fixture controlled by a switch for the
attic furnace. Section 708, UMC.
]18. Show details to comply with Section 709 7r furnace under the floor, or Section 710 for'
roof or outside furnace.
Note on plan: Gas vents and
noncombustible piping passing through three
floors or less shall be effectively draft
stopped at each floor or ceiling.
UBC, Section 1706 (a) 6.
K. WTRTCAL (N&TICN&L =CAL K)
All wiring shall comply with the National
Electrical Code.
E150 Show on the plan the amperage of the
e ectrical service, the location of the service
panel and the location of any subipanels.
31. Show-location-of all electrical
receptacles.
152 Electrical receptacle locations and/or
spacing is not adequate in FAWJ i I (4 Peryr., -
SIU O/ IMJ iA (a' fPØM tti. C(& _tjJI'4
/Wso 17-' flJJ€E"3 £)LTrt t -r LwALL
153 Show at least one convenience outlet other
outlets for laundry, etc., outdoors, in
garages and basements. NEC, Art. 210-52. F Ir
154 Note convenience outlets in bathrooms,
.o , and in garages and basements (other
than for laundry and similar equipment) shall be
GYI protected, NEC, Art. 210-8. ev
Note electrical system ground to be
ided per NEC, Art. 250-81.
L. PLTh1BIM (uiuiae( PITh!BThG• OK)
1516. Show water heater size, type and location
oi{ plans. UPC, Section 1310.
IL 4. Show source for providing combustion air
t6 fuel burning water heater. If wall opening
in an enclosure are used, at least one-half of
the required opening area, shall extend into the
upper twelve inches of the enclosure and
one-half within the lower twelve inches.
UPC, Section 1307.
11
3/25/86
15. Fuel combustion water heater shall not be
installed in bath or bedroom or in a closet
opening into bath or bedroom.
UPC, Section 1309.
19. Provide adequate barrier to protect water
heater from vehicle damage. UPC, Section 1310.
I!60. Show 2 and P Valve on water heater and
how route of discharge line to exterior.
UPC, Section 1007 (e).
161. Provide dryer vent to outside.
UMC, Section 1903.
Note on the plan that hose bibbs and lawn
prinkler systems shall have approved backf low
prevention devices. UPC, Section 1003.
11.3. Shower stall shall accommodate a 30"
4ircle and have a minimum floor area of
1,024 sq. in. UPC, 909 (d).
N. NOISE INJLA.TI(M1 (IXJPLCSE)
f . Show details of duplex common (party)
alls and floor/ceiling assemblies to achieve a
Sound Transmission Class (STC) rating in walls
of 50 decibles and on Impact Insulation Class
(IIC) rating on floor/ceiling of 50 decibles.
Title 25.
l. Show how penetrations of assemblies for.
pping, electrical devices, recessed cabinets,
bathtubs, soffits, or heating ventilating, or
exhaust ducts shall be sealed, lined, or
insulated to maintain required sound
transmission rating. Title 25.
14. Provide insulation in walls.and ceiling to
chieve STC of 50 between garage and living area
if garage use is not controlled by resident.
Title 25.
12
3/25/86
eda
Specify on the building clans all of the
tory energy conservation requirements as
listed on the enclosure titled, "Mandatory
Enermy Conservation Requirements".
Qati
Show the size,type, make, model and
on of the space heating (or cooling)
system and provide heat loss calculations if the
output BTU/Hr. exceeds 45,000. Loc Jiui
0. CARLSBAD S.F.D. & DUPLEXSUPPLtI'r
17. Energy conservation design should be for
Zone 7 . See attached energy packages.
17,. Floor drains must have auto-prime
(city policy).
Qty
Note exhaust fans cannot be ductless type'
policy).
17. New residential units must be pre-piumbed
for future solar water heating. Note "two roof
jacks must be installed" where the water heater
is in the one story garage and directly below
the most south facing roof
(City Ordinance No. 8093).
1-
Note "two 3/4" copper pipes must be
stalled to the most convenient future solar
panel location when the water heater is not in a
one story garage and is not directly below the
most south facing roof.
(City Ordinance No. 8093).
10. All piping for presOnt or future slar
water heating must be insulated wherf in areas
that are not heated or cooled by mechanical
means (city policy).
Incorporate the waterproofing details, on
t)e attached Policy 80-8, where interior living
space occurs below grade at the masonry
wall(s).
:Fps*--! :' ejKii.i .Id(&
State regulations (California Admin. Code)
require that the design satisy one of the
attached alternative energy packages or submit
calculations. The law also requires that many
mandatory conservation items be satisfied.
167 Show on the Title Sheet of the plans, the
required elements of the alternative energy
package that was selected, and next to each
element shàw how you are complying with each
element. If calculations were used, provide
similar data on the plans.5uJ nmuwt 10.
kOOTI0I1 61L4 Li- 1cJL1j) OIL Oi% LAtL4(CXZ UCAPL4 ATh 'RC(t'4E6 A-(P)
2ements
8. The plan sheet showing the required
of the selected energy package, and
listing the design elements showing compliance
with that selected package, must be signed by
either the owner or a licensed professional
i.e., architect, engineer or contractor. A
design professional must note his/her state
license number. Section 1403 of Title 20.
1/9. Show on the plans the "R" value for the
walls, floors, ceiling and related areas.
170 Show double glazing as per Energy Design,
o Glazing Schedule. W PLE'&'O W.4 MeVA&E Cie
171 Show on the plan how shading requirements
e satisfied. I i - Flu& I m VA FALV q&L
1/2. The plans are not in compliance with the
energy conservation compliance package selected
or design calculations provided. Show on plans
conformance as follbws:
l2. Show on the Title Sheet on the plans, the
iformation required by the attached
Developmental Services Sheet 102683.
183 All now residential buildings, including
ditions, require a soils report. Please
submit two copies.
1.. Heavy timber framing, minimum 6" x 10"
beams and minimum 8" x 8" post, for the
structural bean and column supporting the fire
separation between the garage and living area
above, is acceptable if shown on the plans.
(city policy).
i/s.. Please see additional corrections, or
remarks, on the following page.
The City of Carlsbad has contracted with Esgil
Corporation located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123;
telephone number of 619/560-1468, to perform the
plan check for your project. If you have any
questions regarding these plan check items,
please contact
at Esgil Corporation. If you have any questions
regarding City Building permit prccdures,
please contact Carter Darnell at the City of
Carlsbad, 2075 Las Palmas Dr.,
Telephone (619)438-1161
Thank you.
Enclosures:
3.
33
10/6/86
UBC Adopting Ordinance 8792 requires
Fire Retardant roof on all structures
(Sec. 18.04.230). Show compliance
with UBC Section 3203(e).
187 city Ordinance 9792 requires two park-
ing spaces/unit with clear area of
20'x20' i.e. no washing mac Ines, etc..
Show compliance.
Datez 1-3,-i CITY OF CARLSBAD
Prepared byt c Bldg. Dept.
VALUATION AND PLAN CHECK FEE 0 Esgil
PLAN CHECK NO.
BUILDING ADDRESS 5Puc yr
APPLICANT/CONTACT PHONE NO.________________
BUILDING OCCUPANCY - DESIGNER PHONE____________
TYPE OF CONSTRUCTION J—d CONTRACTOR PHONE___________
BUILDING PORTION BUILDING AREA VALUATION
MULTIPLIER
VALUE
-LS-6 dh '1.50 Z11 9
Air Conditionine
Commercial
Residential
Res. or Comm.
Fire Sprinklers
Total Value
Fee Adjusted To Reflect 0 Energy Regulations (Fee x 1.1)
0 Handicapped Regulations (Fee x 1.065)
Building Permit Fee $ 41. OC
Plan Check Fee S $ Z7!70
COMMENTS
8/4/82
ENGINEERING CHECKLIST
Date: 7/2 //I7
Plan Check No.
Project Address: I 1-
Project Nämé:
Field Check Date:
By:
LEGEND
Item Complete
G) Item Incomplete - Needs
Your Action
1,2,3 Number in circle,
indicates plancheck
number that deficiency
was identified
LEGAL REQUIREMENTS
Site Plan
Provide a fully dimensioned site plan drawn to scale. Show: North
zf. u o arrow, property lines, easements, existing and proposed
structures, streets, existing street improvements, right-of-way
width and dimensioned setbacks.
Show on Site Plan: Finish floor elevations, elevations of finish
,
0 0
grade adjacent to building, existing topographical lines,
and proposed slopes, driveway and percent (%) grade and
existing,
drainage
patterns. -
El 0 0 Provide legal description of property.
121" 0 0 Provide assessor's parcel number.
PERMITS REQUIRED
Grading
0 0 Grading permit required. (Separate submittal to Engineering
Department required for Grading Permit).
S. Grading plans in plan check PE___________
J" fl J 7. Need the following completed prior to building permit issuance:
2 0 fl Grading plans signed.
ET El El Grading permit issued.
Grading completed.
Certification letter and compaction reports submitted.
El' El 0 Grading inspected and permit signed off by City Inspector.
EEl 0 0 8. Right-of-Way Permit required• for work in public right-of-way-
(e.g., driveway approach, sidewalk, connection to water main,
etc)..
EEr' 0 0 9. Industrial Waste Permit application required. To be filled out
completely and returned to Development Processing.
FEES REQUIRED
Park-in-Lieu fees required.
Quadrant:, Fee Per Unit: , Total Fee :________
Traffic impact fee required.
Fee Per Unit: , Total Fee:
Bridge and Thoroughfare fee required))47
Fee Per Unit: , Total Fee:
Public facilities fee required. -
Facilities management fee required. Fee:fvI)f#)4tt1 4
li15. Additional EDU's required: )p -e.-.
Sewer connection fee: Sewer permit no.
16. Sewer lateral required:
REMARKS:
0. K. to
•
issue: Date: 7/s?
If you have any* questions about any of the above items identified on this plan
check, please call the Development Processing Department at 438-1161.
W - Q) - W -
m
D 00
PLANNING CHECKLIST
C) W
> > >
Plan Check No. 87-368 Address 2306A)cE 5-r
Type of Project and Use 6F0 4r'orno
0.. 000 0. o.. r) I Zone Use Allowed? YES , NO
Setback: Front OK Side Oi< Rear OK
School District: San Dieguito Encinitas
Carlsbad San Marcos
O LI 0 a Discretionary Action Required YES NO V Type
O 0 fl Environmental Required YES NO X
O 0 0 Landscape Plan Required YES NO
Comments
O 0 0 Coastal Permit Required YES NO
0 Q 0 Additional Comments
OK TO ISSU DATE 7-7
CERTIFICATION OF COMPLIANCE
CITY OF CARLSBAD Plan Check No.
DEVELOPMENT PROCESSING SERVICES DIVISION
2075 LAS PALMAS CARLSBAD, CA 92009
(619) 438-1161
This form shall be used to determine the amount of school fees for a project and to verify
that the project applicant has complied with the school fee requirements. No building
permits for the projects shall be issued until the certification is signed by the
appropriate school district and returned to the City of Carlsbad Building Department.
SCHOOL3STRICT:
ZCarlsbad Unified San Marcos Unified
801 Pine Avenue 270 West San Marcos Blvd.
Carlsbad, CA 92008 (457-4985) San Marcos, CA 92069 (744-4776)
Encinitas Union Elementary
189 Union Street
Encinitas, CA 92024 (944-4306)
Project Applicant:
Project Address: a.
San Dieguito Union High School
625 North Vulcan
Encinitas, CA 92024 (753-6491)
APN: - -
RESIDENTIAL: SQ. FT. (_ of liiig area 3ó Number of dwelling units
- N"
SQ. FT. of covered area SQ. FT. of garage area
COMMERCIAL! INDUSTRIAL: SQ. FT. AREA
Prepared By Date
FEE CERTIFICATION
(To be completed by the School District)
Applicant has complied with fee requirement under Government Code 53080
_____ Project is subject to an existing fee agreement
Project is exempt from Government Code 53080
Final Map approval and construction started before September 1, 1986.
(other school fees paid)
Other
Residential Fee Levied: $ 14 based on L3 a () sq. ft.@ S
Comm/Indust Fee Levied: $____________ based on sq. ft.@
1-.4 lk I k~lj A.
Di'ct Official Title Date
AB 2926 and SB 201 fees are capped at $1.50 per square foot for residential.
AB 2926 is capped at $.25 per square foot for commercial/industrial.