Loading...
HomeMy WebLinkAbout2630 STATE ST; ; CB042480; PermitCity of Carlsbad . jyl 1635 Faraday Av Carlsbad, CA 92008 05-17-2005 \ Residential Permit Permit NO: CB042480 Building Inspection Request Line (760) 602-2725 Job Addresk 2630 STATE ST CBAD Permit Type: RESDNTL Sub Type: RAD Status: ISSUED Parcel No: Lot #: 0 Applied: 06/21/2004 Valuation: $22,449.00 Construction Type: NEW Entered By: KMT Occupancy Group: Reference #: Plan Approved: 05/17/2005 # Dwelling Units: 0 Structure Type: Issued: 05/17/2005 Bedrooms: 0 Bathrooms: 0 Inspect Area: Project Title: HUSTON RES-249 SF PORCH, 684 Orig PC#: SF REMODEL ON RESIDENCE! ADDITION Plan Check#: Applicant: Owner: MIKE FLINTNER 2802 STATE STREET,SUITE C 92008 760-434-8400 Building Permit $199.79 Meter Size Add'I Building Permit Fee $0.00 Add'I Red. Water Con. Fee $0.00 Plan Check $129.86 Meter Fee $0.00 Add'I Plan Check Fee $0.00 SDCWA Fee $0.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $2.24 PFF $0.00 Park in Lieu Fee $0.00 PFF (CFD Fund) $0.00 Park Fee $0.00 License Tax - $0.00 LFM Fee $0.00 License Tax (CFD Fund) $0.00 Bridge Fee $0.00 Traffic Impact Fee $0.00 Other Bridge Fee $0.00 Traffic Impact (CFD Fund) $0.00 BTD #2 Fee $0.00 Sidewalk Fee $0.00 BTD #3 Fee $0.00 PLUMBING TOTAL $83.00 Renewal Fee $0.00 ELECTRICAL TOTAL $20.00 Add'I Renewal Fee $0.00 MECHANICAL TOTAL $52.50 Other Building Fee $0.00 Housing Impact Fee $0.00 Pot. Water Con. Fee $0.00 Housing InLieu Fee $0.00 Meter Size Housing Credit Fee $0.00 Add'I Pot. Water Con. Fee $0.00 Master Drainage Fee $0.00 Red. Water Con. Fee $0.00 Sewer Fee $0.00 Additional Fees $0.00 TOTAL PERMIT FEES $487.39 r IV rrrn ;- ry g Total Fees: $487.39 Total Payments To Date: $129.86 Balance Due: $357.53 PEIT HAS EXPIRED IN ACCO!1AWCE Willi C.B.C. SC1104 10.4.4 AS AEJED 8YM91804.3f) DATE 144 SIATUQ1_. FINAL APPROVAL COP 59 357-53 Date: Clearance: NOTICE: Please take NOTICE that approval of your project includes the imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as lees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any PERMI PPLICATIOFfJ CITY O BthL'4 f; 1635 Faraday Ave., Carlsbad, CA 92008 I- FOR OFFICE USE ONLY 'LAN CHECK NoL1AO44(Q EST. VAL4' i'9 'Ian.Ck. Deposit IaIidated- By rJ%V1" - )ate (s (?I :ThrUJ'INPKMA,I: 2.Jt ,A 6'i'71 l ' L19 4979 06/22/04 000201 02 .A ress (include Bldg/Suite #) . ,. .J -Business Name (at this address) COP. 1229-86 Legal Description c4)_ Lot No. Subdivision Name/Number - I Uni . Phase-No Total # of n-4 units . '4c1e t' f I) Assessor's Parcel # . Existing Use oposedJase 'escription of Work. . . SQ. FT. #of Stories #of.Bedrooms #.of Bathrooms ebbr Address City State/Zip Telephone V Fax # ......•....._.. •.. Nae Address . - City State/Zip . Telephone # j0NTRACTORCOMPANYAME (Sec 7031.5 Business and Professions Code Any City or County which requires a permit to construct alter, improve demolish or repair any structure prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not moretn five hundred dollars ($5001). Cu PC) .9'1 i3 61f -~ A74 Name Address City State/Zip Telephone # State Licp,se # 4010 616 -7 License Class 3 City Business License # /2./ 99ollce Designer Name Address City State/Zip Telephone State License # ::: *___ Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self-insure for workers', compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. . I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the' performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: - - - - Insurance Company __ec.uta POlicy No./ O'f'~I9 - Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($1001 OR LESS) CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. - WARNING: F ure to secure workers' compensation cverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand do era ($ 00,000 addV n to the coilf qbmpensetion, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. SIGNATURE "{ DATE —/7 "O' —1;:'— P hereby affirm that I am exempt from the Contractor's License Law for the following reason: I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold wilhin one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). 0 I, as owner Of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner âf property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). . I am exempt under Section Business and Professions Code for this reason: I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ONO I (have / have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone 'number / contractors license number): I will piovide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number /type of work): PROPERTY OWNER SIGNATURE ' DATE ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES . 0 NO' Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES 0 NO - Is the facility to be constructed within 1,000 feet of the outer boundary of' a school site? 0 YES 0 NO ' IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 1.8;--.TCONSTRU.CTION.;LENDING~AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 309710 Civil Code). LENDER'S NAME '. ' LENDER'S ADDRESS_______________________________________________________ APPLICANT CERTWJCJIOI - _________ I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Cit, of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF-CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF. THE GRANTING OF THIS PERMIT. OSHA An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height EXPIRATION: Every permit issued by th uilding Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authonzed by such permit is not commenc d ithin 180 gays ,from the date of such permit or if the building or work authorized by such perm is suspended or abandoned at any time after the work is co encei r do days Section 106.4.4 Uniform Building Code) J, APPLICANT'S SIGNATURE DATE WHITE ile YELLOW Applicant PINK Finance .1 Inspection List Permit#: CB042480 Type: RESDNTL RAD HUSTON RES-249 SF PORCH, 684 SF REMODEL ON RESIDENCE! ADDITION Date Inspection Item Inspector Act Comments 10/02/2009 92 Compliance Investigation JM CO OK TO EXPIRE OUT PERMIT. BETTE HUSTON IS NOT GOING TO COMPLETE LANDSCAPE PART OF PROJECT AND THEREFORE UNABLE TO FINAL. 10102/2009 92 Compliance Investigation JM CO SEND TO CODE ENFORCEMENT 10/02/2009 92 Compliance Investigation - RI Status on job? 09/26/2008 31 Underground/Conduit-Wirin JM AP OUT DOOR LIGHTS 05/07/2008 19 Final Structural JM CO LIST ON CARD 04/22/2008 19 Final Structural JM CO 04/22/2008 29 Final Plumbing JM CO 04/22/2008 39 Final Electrical JM CO SEE RECORD CARD 04/22/2008 49 Final Mechanical JM AP 11/08/2006 19 Final Structural JM CO LIST ON SITE 11/08/2006 29 Final Plumbing JM AP 11/08/2006 39 Final Electrical JM AP 11/08/2006 49 Final Mechanical JM AP 09/15/2006 27 Shower Pan/Roman Tubs JM AP 09/15/2006 82 Drywall/Ext Lath/Gas Test JM AP SHOWER & D WALL 05/10/2006 17 Interior Lath/Drywall JM AP 05/09/2006 17 Interior Lath/Drywall JM CA STEM 04/14/2006 16 Insulation PC AP 04/07/2006 14 Frame/Steel/Bolting/Weldin JM AP OK TO INSULATE 04/07/2006 22 Sewer/Water Service JM WC 04/07/2006 24 Rough/Topout JM AP 04/07/2006 34 Rough Electric JM AP 04/07/2006 44 Rough/Ducts/Dampers JM AP VERIFY EXHAUST FAN 02/14/2006 15 Roof/Reroof JM AP OK TO COVER ROOF 02/10/2006 13 Shear Panels/HD's JM AP OK TO WRAP 02/10/2006 15 Roof/Reroof JM CO RENAIL PERIMETER FREEZE BLOCKS 12/29/2005 13 Shear Panels/HD's JM NR 12/22/2005 13 Shear Panels/HD's PY PA NORTH WALL 11/30/2005 11 Ftg/Foundation/Piers JM AP OK TO POUR UFER OK 11/29/2005 11 Ftg/Foundation/Piers JM CO NO APPROVED PLANS 11/28/2005 11 Ftg/Foundation/Piers JM CO NO APPROVED PLANS ON SITE 11/28/2005 44 Rough/Ducts/Dampers JM WC 11/17/2005 11 Ftg/Foundation/Piers JM CO AB SPACING/SHEARWALL LETTER/UFER BAR 11/17/2005 12 Steel/Bond Beam JM CO 11/14/2005 21 Underground/Under Floor JM AP 11/14/2005 24 Rough/Topout JM WC 11/10/2005 24 Rough/Topout JM CO RAIN 10/25/2005 33 Service Change/Upgrade JM AP RESIDENCE & R.V. STORAGE LOT METER REL. 10/25/2005 34 Rough Electric JM WC 10/12/2005 34 Rough Electric JM NR Monday, October 05, 2009 Page 1 of 2 09/28/005 21 Underground/Under Floor JIM WC 09/28/2005 31 Underground/Conduit-Wirin JM PA FEED TO PANEL 09/22/2005 21 Underground/Under Floor JM CO NO APPROVED PLANS ON SITE 06/10/2005 31 Underground/Conduit-Wirin JM PA NEW SERVICE AND R V PEDISTAL 06/10/2005 34 Rough Electric JM WC Monday, October 05, 2009 Page 2 of 2 I J City of Carlsbad Bldg Inspection Request For: 10/02/2009 Permit# CB042480 Inspector Assignment: JM Title: HUSTON RES-249 SF PORCH, 684 Description: SF REMODEL ON RESIDENCE! ADDITION Type: RESDNTL Sub Type: RAD Job Address: 2630 STATE ST Suite: Lot: 0 Location: APPLICANT MIKE FLINTNER Owner: Remarks: Status on job? Phone: Inspector: Total Time: CD Description 92 Compliance Investigation Requested By: CHRISTINE Entered By: CHRISTINE Act Co entsi 4m - oL Comments/Notices/Holds Associated PCRs/CVs Original PC# Inspection History Date Description 09/26/2008 31 Underground/Conduit-Wiring 05/0712008 19 Final Structural 04/22/2008 19 Final Structural 04/22/2008 29 Final Plumbing 04/22/2008 39 Final Electrical 04/22/2008 49 Final Mechanical 11/08/2006 19 Final Structural 11/08/2006 29 Final Plumbing 11/08/2006 39 Final Electrical 11/08/2006 49 Final Mechanical 09/15/2006 27 Shower Pan/Roman Tubs 09/15/2006 82 Drywall/Ext Lath/Gas Test 05/10/2006 17 Interior Lath/Drywall 05/09/2006 17 Interior Lath/Drywall 04/14/2006 16 Insulation 04/07/2006 14 Frame/Steel/Bolting/Welding 04/07/2006 22 Sewer/Water Service 04/07/2006 24 Rough/Topout 04/07/2006 34 Rough Electric Act Insp Comments AP JM OUT DOOR LIGHTS CO JM LIST ON CARD CO JM CO JM CO JM SEE RECORD CARD AP JM CO JM LIST ON SITE AP JM AP JM AP JM AP JM AP JM SHOWER & D WALL AP JM CA JM STEM AP PC AP JM OK TO INSULATE WC JM AP JM AP JM J City of Carishail L) J Final Building Inspection Dept: Building Engineering PlanningCMWD St Lite Fire Plan Check #: Date: 03/08/2007 Permit #: CB042480 Permit Type: RESDNTL Project Name: HUSTON RES-249 SF PORCH, 684 Sub Type: RAID SF REMODEL ON RESIDENCE/ ADDITION Address: 2630 STATE ST Lot: 0 Contact Person: Phone: Sewer Dist: Water Dist: Inspected Date By: Inspected: Approved: Disapproved: Inspected Date By: Inspected: Approved: Disapproved: Inspected Date By: Inspected: Approved: ______ Disapproved: Comments: EsGil Corporation In Partnersicip wit/i government for(Building Safety DATE: November 3, 2004 JURISDICTION: Carlsbad PLAN CHECK NO.: 04-2480 PROJECT ADDRESS: 2630 State St. SET: IV o—APPLteAN:[ JURIS. PLAN REVIEWER I FILE PROJECT NAME: SFD Add./Remodel for Bette Huston House The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has -been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: applicant Telephone #: in person Date contacted: (by: ) Fax #: Mail Telephone. Fax In Person REMARKS: City shall the plans. By: Sergio Azuela Enclosures: Esgil Corporation 0 GA 0 MB 0 EJ 0 Pc LOG trnsmtl.dot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In 'artnersllip wit/i government for Bui(dng Safety DATE: November 1, 2004 JURISDICTION: Carlsbad PLAN CHECK NO.: 04-2480 PROJECT ADDRESS: 2630 State St. SET: IV CANT U PLAN REVIEWER U FILE PROJECT NAME: SFD Add./Remodel for Huston .House E The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. Eli The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. EII The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. fl The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Mike Flintjer 2802 State St., Suite C, Carlsbad, CA 92008 lj Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Mike Flintjer Date contacted: it/i 4.j (by ;6) Mail / Telephone/ Fax j/ In Person LI REMARKS: Telephone #: (760) 434-8400 Fax #: (760) 434-8493 By: Sergio 'Azuela Enclosures: Esgil Corporation El GA El MB DEJ 0 Pc 10/25 trnsmtidot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax(858)560-1576 Carlsbad 04-2480 November 1, 2004 RECHECK PLAN CORRECTION LIST JURISDICTION: Carlsbad PROJECT ADDRESS: 2630 State St. DATE PLAN RECEIVED BY COMPLETED: ESGIL CORPORATION: 10/25 REVIEWED BY: Sergio Azuela FOREWORD (PLEASE READ): PLAN CHECK NO.: 04-2480 SET: IV DATE RECHECK November 1, 2004 This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? DYes DNo Carlsbad 04-2480 November 1, 2004 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 17. City shall place their "soils notice" stamp on the plans. 26. Provide truss details and truss calculations for this project. Specify truss identification numbers on the plans. Trusses calculations and details were not provided. Original correction is still applicable. The truss calculations provided were performed by the engineer of record (not by a certified pre-fabricating shop) therefore these trusses will be field-fabricated. Please provide; complete structural design calculations for all connections between the truss members. including ICBO approval # for any truss plates used. Additional corrections may follow. If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. Thank you. EsGil' Corporation In cPartners flip with government for(Building Safety DATE: October 4, 2004 JURISDICTION: Carlsbad PLAN CHECK NO.: 04-2480 PROJECT ADDRESS: 2630 State St. SET: III LICANT JURIS. o PLAN REVIEWER O FILE PROJECT NAME: SFD Add./Remodel for Bette Huston House LI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted, herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. F-1 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. 0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Mike Flintjer 2802 State St., Suite C, Carlsbad, CA 92008 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Mike FIintjer Telephone #: (760) 434-8400 Date contacted: (by: Fax #: (760) 434-8493 Mail--"Telephone FaxL-'in Person D. REMARKS: By: Sergio Azuela Enclosures: Esgil Corporation DGA [:1 MB DEJ 0 Pc 9/27 trnsmtLdot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 04-2480 October 4, 2004 RECHECK PLAN CORRECTION LIST JURISDICTION: Carlsbad PROJECT ADDRESS: 2630 State St. DATE PLAN RECEIVED BY ESGIL CORPORATION: 9/27 REVIEWED BY: Sergio Azuela PLAN CHECK NO.: 04-2480 SET: III DATE RECHECK COMPLETED: October 4, 2004 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, UnifOrm Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? UYes DNo Carlsbad 04-2480 October 4, 2004 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 17. City shall place their "soils notice" stamp on the plans. 19. Revise the plans to show the correct layout of the foundation at the Kitchen Bay Window. Please note that: since the architectural plans are showing this bay window to be cantilevered the foundation plan is showing a continuous foundation under the exterior walls. Additional corrections may follow. Plans are not consistent. See architectural elevations on sheet A-4 and the Foundation and Framing plans, for the Kitchen window as cantilever framing vs. the column foundations shown at the Foundation Plan. Original correction is still applicable. 26. Provide truss details and truss calculations for this project. Specify truss identification numbers on the plans. Trusses calculations and details were not provided. Original correction is still applicable. Please provide evidence that the engineer-of-record (or architect) has reviewed the truss calculation package prepared by others (i.e., a "review" stamp on the truss calculations or a letter). Section 106.3.4.1. The required evidence was not provided. Original correction is still applicable. Provide framing sections through Bay Window. Also clearly show supports for the roof rafters, in perpendicular direction to the trusses. Section 106.3.3. Plans are not consistent. See architectural elevations on sheet A-4 and the Foundation and Framing plans, for the Kitchen window as cantilever framing vs. the column foundations shown at the Foundation Plan. Original correction is still applicable. If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. Thank you. EsGil Corporation In (Partners flip with governmentfor BuiI4ing Safety DATE: September 21, 2004 JURISDICTION: Carlsbad PLAN CHECK NO.: 04-2480 PROJECT ADDRESS: 2630 State St. SET: II O AP QANT O JURIS O P N REVIEWER O FILE PROJECT NAME: SFD Add./Remodel for Bette Huston House El The plans transmitted herewith have been corrected where necessary and su b s t a n t i a l l y c o m p l y with the jurisdiction's building codes. El The plans transmitted herewith will substantially comply with the jurisdiction's bu i l d i n g c o d e s when minor deficiencies identified below are resolved and checked by buildin g d e p a r t m e n t s t a f f . El The plans transmitted herewith have significant deficiencies identified on the enclo s e d c h e c k l i s t and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being he l d a t E s g i l Corporation until corrected plans are submitted for recheck. El The applicant's copy of the check list is enclosed for the jurisdiction to forward to t h e a p p l i c a n t contact person. The applicant's copy of the check list has been sent to: Mike Flintjer 2802 State St., Suite C, Carlsbad, CA 92008 Esgil Corporation staff did not advise the applicant that the plan check has bee n c o m p l e t e d . Esgil Corporation staff did advise the applicant that the plan check has been c o m p l e t e d . Person contacted: Mike Flintjer Telephone* (760)434-8400 (JAJ itt..p.ii.) Date contacted: 1 109 (by: - ) Fax #: (760) 434-8493 Mai/Telephone Fax V In Person [] REMARKS: By: Sergio Azuela Enclosures: Esgil Corporation 0 GA 0 MB 0 EJ D PC 9/14 tmsmU.dot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 04-2480 September 21, 2004 RECHECK PLAN CORRECTION LIST JURISDICTION: Carlsbad PROJECT ADDRESS: 2630 State St. DATE PLAN RECEIVED BY ESGIL CORPORATION: 9/14 REVIEWED BY: Sergio Azuela FOREWORD (PLEASE READ): PLAN CHECK NO.: 04-2480 SET: II DATE RECHECK COMPLETED: September 21, 2004 This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? DYes DNo macvalue.doc Carlsbad 04-2480 September 21, 2004 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. APPLICANT DID PROVIDE ONLY ONE COPY OF SHEET E-1, AND NO CORRECTION RESPONSES. ALL PREVIOUS CORRECTIONS FROM THE CORRECTION LIST DATED JULY 7, 2004 ARE STILL APPLICABLE. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 3. Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2001 edition of the California Building Code (Title 24), which adopts the 1997 UBC, 2000 UMC, 2000 UPC and the 1999 NEC. 4. Provide a fully dimensioned site plan drawn to scale. Section 106.3.3. Include the following: Property lines/easements. Streets/alleys. Existing and proposed buildings and structures. I) Identify existing walls to remain and proposed new walls. 5. Clearly dimension building setbacks from property lines, street centerlines, and from all adjacent buildings and structures on the site plan. Section 106.3.3. 6. Provide a fully dimensioned floor plan showing the size and use of all rooms or areas within the space being improved or altered. Draw the plans to scale and indicate the scale on the plan. Also clearly identify existing walls to remain and proposed new walls. Section 106.3.3. 7. Exterior walls closer than 3 feet to property lines shall be one-hour rated construction and have no openings. Table 5-A. Cafisbad 04-2480 September 21, 2004 8. Exterior walls closer than 3 feet to a property line shall have 30 inch parapets when the floor area per floor exceeds 1,000 square feet. See Section 709.4 for possible exception. 9. Projections, including eaves, may not extend more than 12 inches into the 3 foot setback from the property line. Section 503.2.1. 10. Eaves over required windows shall be not less than 30 inches from the side and rear property lines. Section 1204. 11. Projections, including eaves, shall be one-hour fire-resistive construction, heavy timber or of noncombustible material if they project into the 3' setback area from the property line. Section 705. 12. Show locations of permanently wired smoke detectors with battery backup: Inside each bedroom. Centrally located in corridor or area giving access to sleeping rooms. NOTE: Detectors shall sound an alarm audible in all sleeping areas of the unit. Section 310.9.1. 13. Show that ceiling height for habitable rooms is a minimum of 7'-6". Section 310.6.1. 14. Show ceiling height for laundry rooms, hallways, corridors, and bathrooms is a minimum of 7'-0". Section 310.6.1. 15. Glazing in the following locations should be of safety glazing material in accordance with Section 2406.4 (see exceptions): a) Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface. Window G adjacent to door 3. 16. Specify roof slope. 17. City shall place their "soils notice" stamp on the plans. 18. Clearly identify on the Foundation Plan, the existing foundations and the new foundation with different symbols. Section 106.3.3. 19. Revise the plans to show the correct layout of the foundation at the Kitchen Bay Window. Please note that: since the architectural plans are showing this bay window to be cantilevered the foundation plan is showing a continuous foundation under the exterior walls. Additional corrections may follow. 20. Note on plans that wood shall be 6" minimum above finish grade. Section 1806.1. Carlsbad 04-2480 September 21, 2004 Note on plans that surface water will drain away from building and show drainage pattern. Section 1804.7. Show foundation bolt size and spacing. Foundation bolt size and spacing for shear walls must be clearly shown on the foundation plan. Section 1806.6. a) Normally the AB's size and spacing is included within the "Shear Wall Schedule". Please provide the Shear Wall Schedule" for this project. Specify size, I.C.B.O. number and manufacturer of power driven pins, expansion anchors or epoxy anchors. Show edge and end distances and spacing. Section 106.3.3. Show size, embedment and location of hold down anchors on foundation plan. Section 106.3.3. Note on plan that hold down anchors must be tied in place prior to foundation inspection. Section 108.5.2. Provide truss details and truss calculations for this project. Specify truss identification numbers on the plans. Please provide evidence that the engineer-of-record (or architect) has reviewed the truss calculation package prepared by others (i.e., a "review" stamp on the truss calculations or a letter). Section 106.3.4.1.. . Provide framing sections through Bay Window. Also clearly, show supports for the roof rafters, in perpendicular direction to the trusses. Section 106.3.3. Revise the structural calculations to show the roof material as Tile (10 PSF), instead of Shingle Roof (4 PSF). Please show in the calculations how the redundancy was determined, per Section 1630.1.1. Detail shear transfer connections, including roof and floor diaphragms, to shear walls. Section 2315. a) Provide cross-reference from details to plans for all shear walls. Specify nail size and spacing for all shear walls. Indicate required blocking. Sections 2315 and 2513. Show location of attic access with a minimum size of 22"x30", unless the maximum vertical headroom height in the attic is less than 30". Access must be provided to each separated attic area, shall be located in a hallway or other readily accessible location and 30" headroom clearance is required above the opening. Section 1505.1. Show the location, type and size (BTU's) of all heating and cooling appliances or systems. Carlsbad 04-2480 September 21, 2004 Show minimum 30" deep unobstructed working space in front of furnace. UMC Section 903. Show source of combustion air to furnace, per Chapter 7, UMC. Specify the location and sizes of both of the combustion air openings. Note on plan: Gas vents and noncombustible piping in walls, passing through three floors or less, shall be effectively draft stopped at each floor or ceiling. UBC, Section 711.3. See attached lists for electrical and energy corrections corrections. On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below. Section 106.3.2. REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec. 1701 of the Uniform Building Code. ITEM REQUIRED? REMARKS EXPANSION/EPDXY ANCHORS YES DETAIL 2ISDI.0 The designer shall complete the attached Special Inspection Notice. If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. Thank you. Show on the plan the amperage of the electrical service, the location of the service panel and the location of any sub-panels. If service is over 200 amps, submit single line diagram, panel schedule and load calculations. NEW SERVICE FEEDS DIFFERENT BUILDINGS. A SEPARATE BUILDING SUCH AS THE LAUNDRY BUILDING IS REQUIRED TO HAVE A GROUND ELECTRODE SYSTEM AND A BUILDING DISCONNECTING MEANS. NEC 230-70,250-32 Note on the plans that receptacle outlet locations will comply with NEC Art. 210-52(a). Show on the plans that countertop receptacle outlets comply with NEC Art. 210-52(c), which reads as follows: In kitchens and dining areas of dwelling units a receptacle outlet shall be installed at each counter space wider than 12 inches. Receptacles shall be installed so that no point along the wall line is more than 24 inches measured horizontally from a receptacle outlet in that space. Island and peninsular countertops 12 inches by 24" long (or greater) shall have at least one receptacle. Counter top spaces separated by range tops, refrigerators, or sinks shall be considered as separate counter top spaces. Carlsbad 04-2480 September 21, 2004 4. Per NEC Art. 210-11(c)3, note on the plans that bathroom circuiting shall be either: A 20 ampere circuit dedicated to each bathroom, or At least one 20 ampere circuit supplying only bathroom receptacle outlets. 5. All bedroom branch circuits now require arc fault protection. Note clearly on the plans that "Bedroom branch circuits will be arc fault circuit protected." NEC Art. 210-12(b). 6. Show on the plan that ground-fault circuit-interrupter protection complies with NEC Art. 210-8, which reads as follows: All 125-volt, single-phase, 15- and 20- ampere receptacles installed in bathrooms, outdoors and kitchen counters. 7. Provide plans, calculations and worksheets to show compliance with current energy standards. 8. The window schedule shall clearly describe the required U-factor and solar heat gain coefficient (SHGC) values and demonstrate compliance with the Title 24 energy calculations. 9. The regulations require a properly completed and properly signed Form CF-IR to be either imprinted on the plans, taped to the plans or "sticky backed" on the plans, to allow the building inspector to readily compare the actual construction with the requirements of the approved energy design. 10. All energy items shown on the plans must be in agreement with the information shown on the properly completed Form CF-R. 11. Specify on the building plans all of the mandatory energy conservation requirements as listed on the enclosure titled, "Mandatory Measures Checklist". 12. Show the make, model, type and efficiency of the space heating (or cooling) system. 13. Provide fluorescent general lighting (40 lumens per watt minimum) in kitchen(s) and bathrooms (containing a tub or shower). EsGil Corporation In (Partners flip with çovernmentfor.Bui(&ng Safety DATE: July 7, 2004 JURISDICTION: Carlsbad PLAN CHECK NO.: 04-2480 PROJECT ADDRESS: 2630 State St. SET:I U AP LICANT U JURIS. O PLAN REVIEWER U FILE PROJECT NAME: SFD Add./Remodel for Bette Huston House LI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. U The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. U The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. LII The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Mike Flintjer 2802 State St., Suite C, Carlsbad, CA 92008 LI Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Mike Flintjer Telephone #: (760) 434-8400 Date contacted: 14 Voi (by:c ) Fax #: (760) 434-8493 Mail Telephone Fax ," In Person LI REMARKS: By: Sergio Azuela Enclosures: Esgil Corporation UGA [1 MB EJEJ El PC 6/23 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 04-2480 July 7, 2004 GENERAL PLAN CORRECTION LIST JURISDICTION: Carlsbad PROJECT ADDRESS: 2630 State St. DATE PLAN RECEIVED BY ESGIL CORPORATION: 6/23 REVIEWED BY: Sergio Azuela FOREWORD (PLEASE READ): PLAN CHECK NO.: 04-2480 DATE REVIEW COMPLETED: July 7, 2004 This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any. state, county or city law. To facilitate rechecking, please identify, next to each item, the sheet of the.plans upon which each correction on this sheet has been made and return this sheet with the. revised plans. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? El Yes 0111111,11 p Carlsbad 04-2480 July 7, 2004 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 3. Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2001 edition of the California Building Code (Title 24), which adopts the 1997 UBC, 2000 UMC, 2000 UPC and the 1999 NEC. 4. Provide a fully dimensioned site plan drawn to scale. Section 106.3.3. Include the following: Property lines/easements. Streets/alleys. Existing and proposed buildings and structures. I) Identify existing walls to remain and proposed new walls. 5. Clearly dimension building setbacks from property lines, street centerlines, and from all adjacent buildings and structures on the site plan. Section 106.3.3. 6. Provide a fully dimensioned floor plan showing the size and use of all rooms or areas within the space being improved or altered. Draw the plans to scale and indicate the scale on the plan. Also clearly identify existing walls to remain and proposed new walls. Section 106.3.3. 7. Exterior walls closer than 3 feet to property lines shall be one-hour rated construction and have no openings. Table 5-A. 8. Exterior walls closer than 3 feet to a property line shall have 30 inch parapets when the floor area per floor exceeds 1,000 square feet. See Section 709.4 for possible exception. 9. Projections, including eaves, may not extend more than 12 inches into the 3 foot setback from the property line. Section 503.2.1. 'S Carlsbad 04-2480 July 7, 2004 10. Eaves over required windows shall be not less than 30 inches from the side and rear property lines. Section 1204. 11. Projections, including eaves, shall be one-hour fire-resistive construction, heavy timber or of noncombustible material if they project into the 3' setback area from the property line. Section 705. 12. Show locations of permanently wired smoke detectors with battery backup: Inside each bedroom. Centrally located in corridor or area giving access to sleeping rooms. NOTE: Detectors shall sound an alarm audible in all sleeping areas of the unit. Section 310.9.1. 13. Show that ceiling height for habitable rooms is a minimum of 7'-6". Section 310.6.1. 14. Show ceiling height for laundry rooms, hallways, corridors, and bathrooms is a minimum of 7'-0". Section 310.6.1. 15. Glazing in the following locations should be of safety glazing material in accordance with Section 2406.4 (see exceptions): a) Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface. . Window G adjacent to door 3. 16. Specify roof slope. 17. City shall place their "soils notice" stamp on the plans. 18. Clearly identify on the Foundation Plan, the existing foundations and the new foundation with different symbols. Section 106.3.3. 19. Revise the plans to show the correct layout of the foundation at the Kitchen Bay Window. Please note that: since the architectural plans are showing this bay window to be cantilevered the foundation plan is showing a continuous foundation under the exterior walls. Additional corrections may follow. • 20. Note on plans that wood shall be 6" minimum above finish grade. Section 1806.1. 21. Note on plans that surface water will drain away from building and show drainage pattern. Section 1804.7. 22. Show foundation bolt size and spacing. Foundation bolt size and spacing for shear walls must be clearly shown on the foundation plan. Section 1806.6. a) Normally the AB's size and spacing is included within the "Shear Wall Schedule". Please provide the "Shear Wall Schedule" for this project. Carlsbad 04-2480 July 7, 2004 Specify size, I.C.B.O. number and manufacturer of power driven pins, expansion anchors or epoxy anchors. Show edge and end distances and spacing. Section 106.3.3. Show size, embedment and location of hold down anchors on foundation plan. Section 106.3.3. Note on plan. that hold down anchors must betied in place prior to foundation inspection. Section 108.5.2. Provide truss details and truss calculations for this project. Specify truss identification numbers on the plans. Please provide evidence that the engineer-of-record (or architect) has reviewed the truss calculation package prepared by others (i.e., a "review" stamp on the truss calculations or letter). Section 106.3.4.1. Provide framing sections through Bay Window. Also clearly show supports for the roof rafters, in perpendicular direction to the trusses. Section 106.3.3. Revise the structural calculations to show the roof material as Tile (10 PSF), instead of Shingle Roof (4 PSF). Please show in the calculations how the redundancy was determined, per Section 1630.1.1. Detail shear transfer connections, including roof and floor diaphragms, tô:shear walls. Section 2315. a) Provide cross-reference from details to plans for all shear walls. Speôify nail size and spacing for all shear walls. Indicate required blocking. Sections 2315 and 2513. Show location of attic access with a minimum size of 22"x30", unless the maximum vertical headroom height in the attic is less than 30". Access must be provided to each separated attic area, shall be located in a hallway or other readily accessible location and 30" headroom clearance is required above the opening. . Section 1505.1, Show the location, type and size (BTU's) of all heating and cooling appliances or. systems. Show minimum 30" deep unobstructed working space in front of furnace. UMC Section 903. Show source of combustion air to furnace, per Chapter 7, UMC. Specify the location and sizes of both of the combustion air openings. Carlsbaà 04-2480 July 7, 2004 37. Note on plan: Gas vents and noncombustible piping in walls, passing through three floors or less, shall be effectively draft stopped at each floor or ceiling. UBC, Section 711.3. 38. Show on the plan the amperage of the electrical service, the location of the service panel and the location of any sub-panels. If service is over 200 amps, submit single line diagram, panel schedule and load calculations. 39. Note on the plans that receptacle outlet locations will comply with NEC Art. 210-52(a). 40. Show on the plans that countertop receptacle outlets comply with NEC Art. 210-52(c), which reads as follows: In kitchens and dining areas of dwelling units a receptacle outlet shall be installed at each counter space wider than 12 inches. Receptacles shall be installed so that no point along the wall line is more than 24 inches measured horizontally from a receptacle outlet in that space. Island and peninsular countertops 12 inches by 24" long (or greater) shall have at least one receptacle. Counter top spaces separated by range tops, refrigerators, or sinks shall be considered as separate counter top spaces. 41. Per NEC Art. 210-11 (c)3, note on the plans that bathroom circuiting shall be either: A 20 ampere circuit dedicated to each bathroom, or At least one 20 ampere circuit supplying only bathroom receptacle outlets. 42. All bedroom branch circuits now require arc fault protection. Note clearly on the plans that "Bedroom branch circuits will be arc fault circuit protected." NEC Art. 210-12(b). 43. Show on the plan that ground-fault circuit-interrupter protection complies with NEC Art. 210-8, which reads as follows: All 125-volt, single-phase, 15- and 20- ampere receptacles installed in bathrooms, outdoors and kitchen counters. 44. Provide plans, calculations and worksheets to show compliance with current energy standards. 45. The window schedule shall clearly describe the required U-factor and solar heat gain coefficient (SHGC) values and demonstrate compliance with the Title 24 energy calculations. 46. The regulations require a properly completed and properly signed Form CF-1 R to be either imprinted on the plans, taped to the plans or "sticky backed" on the plans, to allow the building inspector to readily compare the actual construction with the requirements of the approved energy design. 47. All energy items shown on the plans must be in agreement with the information shown on the properly completed Form CF-IR. 48. Specify on the building plans all of the mandatory energy conservation requirements as listed on the enclosure titled, "Mandatory Measures Checklist". Carlsbad 04-2480 July 7, 2004 Show the make, model, type and efficiency of the space heating (or cooling) system. Provide fluorescent general lighting (40 lumens per watt minimum) in kitchen(s) and bathrooms (containing a tub or shower). Note on the plans: "The manufactured windows shall have a label attached certified by the National Fenestration Rating Council (NFRC) and showing compliance with the energy calculations." On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below. Section 106.3.2. . REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec. 1701 of the Uniform Building Code. ITEM REQUIRED? REMARKS EXPANSION/EPDXY ANCHORS YES DETAIL 2/SDI.0 The designer shall complete the attached Special Inspection Notice. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. Thank you. Cailsbad 04-2480 July 7, 2004 City of Carlsbad •B uil di n g-D epart men t BUILDING DEPARTMENT NOTICE OF REQUIREMENT FOR SPECIAL INSPECTION Do Not Remove From Plans Plan Check No. 04-2480 Job Address or Legal Description 2630 State St. Owner Address You are hereby notified that in addition to the inspection of construction provided by the Building Department, an approved Registered Special Inspector is required to provide continuous inspection during the performance of the phases of construction indicated on the reverse Side of this sheet. The Registered Special Inspector shall be approved by the City of Carlsbad Building Department prior to the issuance of the building permit. Special Inspectors having a current certification from the City of San Diego, Los Angeles, or ICBO are approved as Special Inspectors for the type of construction for which they are certified. The inspections by a Special Inspector do not change the requirements for inspections by personnel of the City of Carlsbad building department. The inspections by a Special Inspector are in addition to the inspections normally required by the County Building Code. The Special Inspector is not authorized to inspect and approve any work other than that for which he/she is speèifically assigned to inspect. The Special Inspector is not authorized to accept alternate materials, structural changes, or any requests for plan changes. The Special Inspector is required to submit written reports to the City of Carlsbad building department of all work that he/she inspected and approved. The final inspection approval will not be given until all Special Inspection reports have been received and approved by the City of Carlsbad building department. Please submit the names of the inspectors who will perform the special inspections on each of the items indicated on the reverse side of this sheet. (over) V Carlsbad 04-2480 July 7, 2004 SPECIAL INSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION: PLAN CHECK NUMBER: OWNER'S NAME: I, as the owner, or agent of the owner (contractors may not employ the special inspector), certify that I, or the architect/engineer of record, will be responsible for employing the special inspector(s) as required by Uniform Building Code (UBC) Section 1701.1 for the construction project located at the site listed above. UBC Section 106.3.5. Signed I, as the engineer/architect of record, certify that I have prepared the following special inspection program as required by UBC Section 106.3.5 for the construction project located at the site listed above. Englnee,elArthItect's Seal & Signature Hero Signed 1. List of work requiring special inspection: • Soils Compliance Prior to Foundation Inspection U Field Welding U Structural Concrete Over 2500 PSI U High Strength Bolting U Prestressed Concrete U Expansion/Epoxy Anchors U Structural Masonry U Sprayed-On Fireproofing U Designer Specified U Other 2. Name(s) of individual(s) or firm(s) responsible for the special inspections listed above: 3. Duties of the special inspectors for the work listed above: Special inspectors shall check in with the City and present their credentials for approval prior to beginning work on the job site. Carlsbad 04-2480 July 7, 2004 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 04-2480 PREPARED BY: Sergio Azuela DATE: July 7, 2004 BUILDING ADDRESS: 2630 State St. SFD Add./Rem./Bette Huston's House BUILDING OCCUPANCY: R-3 TYPE OF CONSTRUCTION: V-N BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Dwelling Add. 684 98.00 67,032 Porch 249 10.75 2,677 Air Conditioning 684 3.00 2,052 Fire Sprinklers TOTAL VALUE 71,761 Jurisdiction Code Icb 113y Ordinance 1994 UBC Building Permit Fee 1994 UBC Plan Check Fee Type of Review: 1 Complete Review J Structural Only 0 Other 0 Repetitive Fee Repeats Hourly __ Hour * Esgil Plan Review Fee I $429.76! I $279.341 I $240.671 Comments: Sheet I of I macvalue.doc S C it y of Carlsbad S . I ui . I - 11.11 iL-i-I dl IK!I BUILDING PLANCHECK CHECKLIST DATE: 1--c.b-.OI . PLANCHECK NO.: CB 01 — BUILDING ADDRESS: c2(3O 5Je &. PROJECT DESCRIPTION: ASSESSOR'S PARCEL NUMBER: ,,26 3 In I EST. VALUE: 9, 'I'!'7 ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this. report can result in suspension of permit to build. DENIAL Please se—tte attached report of deficiencies marked wlth/ Make necessary corrections to plans or specifications for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. By: Date: 9 El A Right-of-Way permit is required prior to construction of the following improvements: By: Date: By: . Date: ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT: By: C1 Dedication Application o Dedication Checklist o Improvement Application El Improvement Checklist 0 Future Improvement Agreement 0 Grading Permit Application 0 Grading Submittal Checklist 1. IJ Right-of-Way Permit Application E] Right-of-Way Permit Submittal Checklist and Information Sheet 0 Sewer Fee Information Sheet Date: ENGINEERING DEPT. CONTACT PERSON Name: TAN IVA BARROWS___________ City of Carlsbad Address: 1635 Faraday Avenue, Carlsbad, CA 92008 Phone: (760) 602-2773 CFD INFORMATION Parcel Map No: Lots: Recordation: Carlsbad Tract: 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-2720 • FAX (760) 602-8562 F:BUILDING PLANCHECK 0(1.01 FORMA= 1 Rev. 7114100 BUILDING PLANCHECK CHECKLIST / SITE PLAN ND3RD 0 17' 0 1. Provide a fully dimensioned site plan drawn to scale. Show: 1• / f A. North Arrow / F. Right-of-Way Width & Adjacent Streets Existing & Proposed Structures G. Driveway widths \Existing Street Improvements H. jExisting or proposed sewer lateral \ \ D. \Property Lines I. JExisting or proposed water service E. asements J. /Existing or proposed irrigation service El El 2; Show on site plan: / A. Drainage Patterns 1. Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. ADD THE FOLLOWING. NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building." xisting & Proposed Slopes and Topography ize, type, location, alignment of existing or proposed sewer and water service (s) at serves the project. Each unit requires a separate service, however, second / welling units and apartment complexes are an exception. / D. Sewer and water laterals should not be located within proposed driveways, per standards. • . 0 3. Include on title sheet: . • 7 c? Site address • . • Assessor's Parcel Number • C. Legal Description For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION F:WUILDING PI.ANCIIEcX CKI.ST FORM.doC 2 Rev. 7114100 C4 BUILDING PLANCHECK CHECKLIST 1ST 2ND RD DISCRETIONARY APPROVAL COMPLIANCE O 0 4a. Project does not comply with the following Engineering Conditions of approval for Project No...____________________________________________ 0 0 0 4b. All conditions are in compliance. Date: R DEDICATION REQUIREMENTS . O 0 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ 15.000 , pursuant to Carlsbad Municipal Code Section 18.40.030. . . Dedication required as follows: Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 W x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner(s). prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completed by: Date: IMPROVEMENT REQUIREMENTS 0 0. El 6a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever . the value of the construction exceeds $ 75.000 , pursuant to Carlsbad. Municipal Code Section 18.40.040. Public improvements required as follows: Attached please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on the F:BUILDING PLANCHECI( CILST FORM.doc 3 • . • Rev. 7114100 4 BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD. checklist must be submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit. Improvement Plans signed by: . Date: E 6b. Construction of the public improvements may be deferred pursuant to Carlsbad : Municipal Code Section 18.40. Please submit a recent ptoperty title report or current grant deed on the property and processing fee of $310 so we may prepare the necessary Neighborhood Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit. Future public improvements required as follows: D 0 6c. Enclosed please find your Neighborhood Improvement Agreement. Please return agreement signed and notarized to the Engineering Department. Neighborhood Improvement Agreement completed by:' Date: 6d. No Public . Improvements required.. SPECIAL NOTE: Damaged or defective improvements found adiacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. • GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. 0 ED 7a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities (cut, fill import, export). 0. 0 0 • 7b. Grading Permit required. A separate grading plan prepared by a registered Ciyil Engineer must be submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by: Date: O • 0 0 7c. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) • F:BUlLOING PtANCHEOC CICLST FORM ADC 4 • Rev. 7114100 I U BUILDING PLANCHECK CHECKLIST 1ST ND RD' El El 7d .No Grading Permit required. 0 El El 7e. If grading is not required, write "No Grading" on plot plan. MISCELLANEOUS PERMITS El El 8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. Right-of-Way permit required for: El 0 9. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List. You may telephone (760) 4382722, extension 7153 for assistance. Industrial Waste permit accepted by: Date: El El 10. NPDES PERMIT Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit. The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas. Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first. El Z.E1 11. O Ire d fees are attached • No fees required WATER METER REVIEW • 0 ILb" El 12a. 'Domestic (potable) Use , Ensure that the meter proposed by the owner/developer is not oversized. Oversized. meters are inaccurate during low-flow conditions. If it is oversized, for the life of the meter, the City will not accurately bill the owner for the water used. . All single family dwelling units received "standard" 1" service with 5/8" service. F3UI WING PLANCIlEcK CKLST FORM doe Rev. 7114100 BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm). A typical fixture count and water demand worksheet is attached. Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit. . Maximum service and meter size is a 2" service with'a 2" meter. If a developer is proposing a meter greater than 2", suggest the installation of multiple 2" services as needed to provide the anticipated demand. (manifolds are considered on case by case basis to limit multiple trenching into the street). 0 12b. Irrigation Use (where recycled water is not available) All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval. The developer must provide these calculations. Please follow these guidelines: • If the project is a newer development (newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets. If so, at the water meter station, the demand in gpm may be listed there. Irrigation services are listed with a circled "I", and potable water is typically a circled "W". The irrigation service-should look like: STA 1+00 Install 2" service and S 1.5: meter (estimated 100 gpm) If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (w/ a right of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach). Typically, Larry Black has already reviewed this if landscape plans have been prepared, but the applicant must provide the calculations to you for your use. Once you have received a good example of irrigation calculations, keep a set for your reference. In general the calculations will include: Hydraulic grade line Elevation at point of connection (POC) Pressure at POC in pounds per square inch (PSI) Worse case zone (largest, farthest away from valve Total Sprinkler heads listed (with gpm use per head) . Include a 10% residual pressure at point of connection 3. In general, all major sloped areas of a. subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA). As long as the project is located within the City recycled water F:BUILOING PLANCHECK CKLST F0RM40c 6 Rev. 7114100 .-.. . BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD . . service boundary, the City intends on switching these irrigation services/meters to a new recycled water line in the future. El El 12c. Irrigation Use (where recycled water is available) • Recycled water meters are sized the same as the irrigation meter above.. If a project fronts a street with recycled water, then they should be connecting to this line, to irrigate slopes within the development. For subdivisions, this should have been identified, and implemented on the improvement plans. Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees. However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge. If within three years, the recycled water line 'is charged with recycled water by CMWD, then the applicant can apply for a refund to the • San Diego County Water Authority (SDCWA) for a refund.. However, let the applicant know that we cannot guarantee the refund, and they must deal with the SDCWA for this. El El 0 13. Additional Comments: F:8UlLDING PLANCHECI( CKLST FORM.doc 7 . . Rev. 711410,0 JULY 12, 2004 TO: BUILDING DEPARTMENT FROM: Planning Technician, Redevelopment Department REMODEL AND ADDITION TO EXISTING PATIO AT 2630 STATE STREET - PLAN CHECK NO. 042480 I have reviewed the building plans for the above referenced project. The project is exempt from the redevelopment permit process, because the proposed remodel consists of relocating internal floor space from the south to the north part of the unit. The proposed patio addition and remodel qualifies as an exterior improvement to an existing structure which does not result in the intensification of the existing use. Therefore, no land use permit is required. I do not have any objections to, the issuance of the building permit for this project. This information has been entered into Permits Plus. If you have any questions, please contact me at x2813. REBECA VAZ'QlJEZ