HomeMy WebLinkAbout2832 STATE ST; ; CB150727; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 07-08-2015 Commercial/Industrial Permit Permit No: C8150727 Building Inspection Request Line (760) 602-2725 Job Address: 2832 STATE ST CBAD Permit Type: TI Sub Type: COMM Status: ISSUED Parcel No: 2031811300 Lot #: 0 Applied: 03/09/2015 Valuation: $86,336.00 Construction Type: 5B Entered By: JMA Occupancy Group: Reference # Plan Approved: 07/08/2015 • Issued: 07/08/2015 Inspect Area Plan Check #: Project Title: SOMEWHERE IN TIME: 1,993 SF TI RETAIL TO SAME Applicant: Owner: MASTER TOUCH CONSTRUCTION, INC WARD FAMILY TRUST 01-20-89 982 EL PAJ000 PL 9455 ORANGE GROVE BLVD #0 VISTA CA 92084-7036 PASADENA CA 91105 619-843-9090 Building Permit $568.73 Meter Size Add'l Building Permit Fee $0.00 Add'l Red. Water Con. Fee $0.00 Plan Check $398.11 Meter Fee $0.00 Add'I Building Permit Fee $0.00 SDCWA Fee $0.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $24.17 PFF (3105540) $0.00 Park Fee $0.00 PFF (4305540) $0.00 LFM Fee $000 License Tax (3104193) $0.00 Bridge Fee $0.00 License Tax (4304193) $0.00 BTD #2 Fee $0.00 Traffic Impact Fee (3105541) $0.00 BTD #3 Fee $0.00 Traffic Impact Fee (4305541) $0.00 Renewal Fee $0.00 PLUMBING TOTAL $0.00 Add'l Renewal Fee $0.00 ELECTRICAL TOTAL $62.00 Other Building Fee $0.00 MECHANICAL TOTAL $0.00 Pot. Water Con. Fee $0.00 Master Drainage Fee $0.00 Meter Size Sewer Fee $0.00 Add'l Pot. Water Con. Fee $0.00 Redev Parking Fee $0.00 Red. Water Con. Fee $0.00 Additional Fees $0.00 Green Bldg Stands (5B1473) Fee $4.00 HMP Fee ?? Fire Expedidted Plan Review . $0.00 Green Bldg Standards Plan Chk ?? TOTAL PERMIT FEES $1,057.01 Total Fees: $1,057.01 TotaIyments To Date: $1,057.01 Balance Due: $0.00 Insoector: FINAL APPROVAL I _ Date: 9/i' 7/ 2/i 1& Clearance: I NOTICE: Please take NOTIVE ffaapprovaI of your project includes the "Imposition" 'of fees, dedications, reservations, or other exactions hereafter collectively referred to as fees/exactions." Yof have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required informaUon with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any ITHE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: DPLANNING DENGINEERING [--]BUILDING DFIRE DHEALTH EJHAZMATIAPCD I Building Permit Application Plan Check No. CM (01 Est. Value 3 m City of kL 1635 Faraday Ave., Carlsbad, CA 92008 Cd1sbad Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. Deposit sc,, !$' email: building©carlsbadca.gov Date 3/ 1 / 2-a I '5' Iswppp I www.carlsbadca.gov JOB ADDRESS ISUITE#,ISPACEC/UNITC IAPN. - - - CT/PROJECT # LOT# -S PHASE# #OFUNITI # BEDROOMS #8ATHROOMS TENANT BUSINESS NAME CONSTR. TYPE 0CC. GROUP DESCRIPTION OF WORK: include Square Feet of Affected A,ea(s) Yb —& EXISTING USE - PROPOSED USE GARAGE (SF) PATIOS (SF) DECKS(SF) FIREPLACE l AIR CONDITIONING I I SI:I . N0111 YESIN0I IFIRESPRINKLERS YES[-] NO[—] APPLICANT NAME Primary Contact /(A k,Q rth& PROPERTY OWNER NAME P.-1 Cu 1ef ADDRESS ADDRESS _________________________ CITY STATE ZIP C CITY STATE ZIP PH0N -oo PHONE FAX EMAIL4J EMAIL Stt DESIGN PROFESSIONAL CONTRACTOR BUS. NAME ou c I., 4 ^4fgckon 'T.,,ç ADDRESS - ADDRESS CITY • STATE ZIP CITY ZIP it c4-, STATE , PHONE FAX PHONE FAX I C(o)t EMAIL EMAIL STATE LIC. # STATE LIc.# 4 5 CLASS CITY BUS. LIC.# (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, altei, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for Such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law a? ter 9, commanding with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). 6@ii8° 9Wo Compensation Declaration: I hereby affijrn under penalty of pe4ury one of the following declarations: ave and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance canter and policy number are: Insurance Co. Policy No. Expiration Date This section need not be completed tithe permit is for one hundred dollars ($100) or less. []Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of Califomia. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, damages as provided for In Section 3706 of the Labor code, Interest and attorney's fees. £CONTRACTORSIGNATURE ,*IQ DAGENT DATES' ®L?o®w I hereby affirm that lam exempt from Contractor's License Law for the following season: [] I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). [J I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. Dyes [—]NO 2.l(have I have not) signed an application for a building permit for the proposed work. 3.1 have contracted with the following person (firm) to provide the proposed construction (include name address! phone !contractors' license number): 4. I plan to provide portions of the work, bull have hired the following person to coordinate, supervise and provide the major work (include name! address / phone contractors' license number): 5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name! address/phone !type of work): .gPROPERTY OWNER SIGNATURE - []AGENT DATE 1®[J f!) f 1J DX Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Yes No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Yes No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Yes No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. !. I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address tm . :•;• Icei1ifythatIhavereadtheappIlcationandstatethattheaboveinthrmaIion isconectandthattheinformationontheplansisaxurate.IagreetocomptywIthaII City ordinances and Stutulaws Matting tobuildlngconstnictlon. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA An OSHA permit is required for excavations over 50 deep and demotion or construction of structures over 3stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit isnot commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 1 06A Unibrni Building Code). £APPLICANT'S SIGNATURE /V. () Ole DATE "IS) /c / 7 STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. CER TIFICATE OF OCCUPANCY (Co m mercial SIJ Fax (760) 602-8560, Email bUiIdina(äcarIsbadCa.gOv or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. CO#: (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE ZIP Carlsbad CA PHONE FAX EMAIL OCCUPANTS BUS. LIC. No. DELIVERY OPTIONS PICK UP: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On P. 1) MAIL TO: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg. MAIL/ FAX TO OTHER: ASSOCIATED CB# NO CHANGE IN USE / NO CONSTRUCTION CHANGE OF USE / NO CONSTRUCTION ..gAPPLICANT'S SIGNATURE DATE Inspection List Permit#: CB150727 Type: TI COMM SOMEWHERE IN TIME: 1,993 SF TI RETAIL TO SAME Date Inspection Item Inspector Act 09/16/2015 89 Final Combo - RI 09/16/2015 89 Final Combo PY AP 09/14/2015 89 Final Combo - RI 09/14/2015 89 Final Combo - RI 09/14/2015 89 Final Combo PY NS 09/11/2015 89 Final Combo - RI 09/11/2015 89 Final Combo PY NR 08/28/2015 17 Interior Lath/Drywall PY AP 08/24/2015 84 Rough Combo PY AP 07/27/2015 21 Underground/Under Floor PY AP Comments COF EMAILING CARD/AM PLEASE U Thursday, September 17, 2015 Page 1 of 1 ' C8150727 2832 STATE ST CITY 0; 4 SOMEWHERE IN TIME: 1,993 SF TI CARLSBAD INSPECTION RECORD RETAIL TOSAME Building Division TI COMM RI INSPECTION RECORD CARD WITH APPROVED Lot#: MASTER TOUCH CONSTRUCTION, INC PLANS MUST BE KEPT ON THE JOB tJ CALL BEFORE 3:30 pm FOR NEXT WORK DAY INSPECTION JZ FOR BUILDIN INSPECTION CALL: 760-602-2725' RECORD COPY OR GO TO: www.Carlsbadca.gov/Building AND CLICK ON Request Inspection DATE: 7IP1I IF' YES 1$ CHECkED BELOW THAT DIVISION IF YOU HAVE ANY QUESTIONSPLEASE CALL S APPROVAL THE APPLICABLE IS REQUIRED PRIOR TO REQUESTING A FINAL BUILDING INSPECTION DIVISIONS AT THE PHONE NUMBERS PROVIDED BELOW. AFTER ALL REQUIRED APPROVALS ARE SIGNED OFF— FAX TO 760-602-8560, EMAIL TO BLDGINSPECTIONS@CARLSBADCA.GOV OR BRING IN A COPY OF THIS CARD TO: 1635 FARADAY AVE., CARLSBAD, CA 92008. BUILDING INSPECTORS CAN-BE REACHED AT 760-602-2700 BETWEEN 7:30 AM - 8:00 AM THE DAY OF YOUR INSPECTION. Allow 48 hours 760-944-8463 Required Requesting ate Inspector Planning/Landscape MA CM&I (Engineering Inspcctionsl 760-438-3891 before 2 Fire Prevention 760-602-4660 T Allow L:: hours • Tvoe of Inspection Type or Inspection coom it ij:1U1ts]II. [ Date #11 FOUNDATION I Inspectorcooe st ELECTRICAL #31 0 ELECTRIC UNDERGROUND 0 UFER Inspector #12 REINFORCED STEEL #34 ROUGH ELECTRIC #66 MASONRY PRE GROUT 1 #33 0 ELECTRIC SERVICE 0 TEMPORARY 0 GROUT O WALL DRAINS #35 PHOTOVOLTAIC #10 TILT PANELS . #39 FINAL #11 POUR STRIPS #41 UNDERGROUND & PIPING #11 COLUMN FOOTINGS #14 SUBFRAME 0 FLOOR 0 CEILING #44 DDUCT&PLENUM DREF.PIPING #15 ROOF SHEATHING #43 HEAT-AIR COND. SYSTEMS #13 EXT. SHEAR PANELS #49 FINAL #16 INSULATION #18 EXTERIOR LATH #81 UNDERGROUND (11,12,21,31) #17 INTERIOR LATH & DRYWALL 'f3f/4. .,&tj #82 DRYWALLIE.XT LATH, GAS TES (1718.23) #51 POOLEXCA/STEEL/BOND/FENCE . #83 ROOF SHEATING, EXT SHEAR (13,15) , , _____________ #55 PREPLASTER/FINAL #84 FRAME ROUGH COMBO (14,24,34,44) ________ #19 FINAL #85 T.Bar(14,24,34,44) 11115-T-7-7-W-11111--il ELI JI:II[_ #22 O SEWER &BL/CO OPL/CO Date Inspector #89 FINAL OCCUPANCY (19,29,39,49) Date Inspector I:1 #21 UNDERGROUND OWASTE OWTR 1J-7/2ets #24 TOPOUT OWASTE OWTR A/S UNDERGROUND VISUAL #27 TUB & SHOWER PAN A/S UNDERGROUND HYDRO #23 OGASTEST OGASPIPING . A/S UNDERGROUND FLUSH . '1 #25 WATER HEATER A/S OVERHEAD VISUAL .•.. _____________ #28 SOLAR WATER A/S OVERHEAD HYDROSTATIC #29 FINAL , A/S FINAL F/A ROUGH-IN #600 PRE-CONSTRUCTION MEETING F/A FINAL #603 FOLLOW UP INSPECTION FIXED EXTINGUISHING SYSTEM ROUGH-IN - #605 NOTICE TO CLEAN FIXED EXTING SYSTEM HYDROSTATIC TEST - #607 WRITTEN WARNING FIXED EXTINGUISHING SYSTEM FINAL #609 NOTICE OF VIOLATION MEDICAL GAS PRESSURE TEST #610 VERBALWARNING MEDICAL GAS FINAL REV 1012012 SEE BACK FOR SPECIAl. NOTES EsGil Corporation In Partnersfiip wit/i government for Bui(iing Safety DATE: 6/16/15 0 APPLICANT JURISDICTION: City of Carlsbad U PLAN REVIEWER U FILE PLAN CHECK NO.: 15-0727 SET: IV PROJECT ADDRESS: 2832 State Street PROJECT NAME: Somewhere inTime - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. E The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. E The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: EsGil Corporation staff did not advise the applicant that the plan check has been completed. E EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: A# Date contacted: (by: ) Email: iP' i)jt Mail TeIe, I V hone Fax In Person / Oc t REMARLO-3 4' Will Foss, the disabled access te requints will be determined by City staff and'dd notes in red on sheet TI-I. By: Doug Moody Enclosures: EsGil Corporation 0 GA 0 EJ IJ MB 0 PC 6/9/15 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 ) EsGil Corporation In (Partnership with government for(Building Safety DATE: 4/15/15 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 15-0727 SET: III U APPLICANT 4u RIS. 1/u PLAN REVIEWER U FILE PROJECT ADDRESS: 2832 State Street PROJECT NAME: Somewhere in Time - TI fl The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Mike Freda Telephone #: 619-843-9090 Date contacted: (by: ) Email: mfreda760@cox.net ,L.Mait.f Telephone Fax In Person LI REMARKS: By: Doug Moody Enclosures: EsGil Corporation 0 GA 0 EJ 0 MB 0 PC 4/8/15 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad 15-0727 4/15/15 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. These corrections are in response to items not fully addressed or as the result of information provided, the text in bold underlined print indicates the unresolved issue. 11. Provide a section view of the new soffits. Show: Method of attaching top to the structure and lateral bracing. No information provided. The details on sheet TI-3 indicate "truss clip" what are these? How are they connected? Are they rated to support the soffit? Show height of the soffit from floor, soffit to roof framing or floor framing 12. Provide a section view of all new interior partitions. Show: a) Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing. No information provided. See comment above. 13. It appears the lighting system is to be altered, please provide complete plans. Please provide the required energy compliance forms. The LTI forms shall be signed and imprinted on the plans. The forms are not complete and not consistent with the plans. Please correct. All of the required forms must be imprinted on the plans and they must be signed by both the author and designer. 18. Please provide panel schedules, indicate new and existing loads. Please indicate on the plans the location of the electrical panel and detail the required working clearance. Nothing is shown on the plans. Please correct. I was unable to find the electrical panel or a panel schedule anywhere on the plans? City of Carlsbad 15-0727 4/15/15 Show on the site plan the complying disabled accessible path of travel from the disabled accessible parking spaces to the primary entrance of the tenant space. Please provide detailed plans of the path of travel, indicate slope and width, any pedestrian ramps, curb ramps, walks, handrails, provide dimensioned parking stall details etc. No response. Provide a complete site plans it appears the site has 10 parking stall in the rear of which at least one must be accessible. Sales and service counters shall have a portion of the counter which is at least 36" in length with a maximum height of 34 inches. Section 11 B-904.4. 1. No response. No accessible counter is shown? 29. Show that the water closet is located in a space which provides: A clear space at the water closet in compliance with Section 11 B-604.3.2 (this prohibits any fixtures from encroaching into the clear space at the rear wall). The restroom is non-compliant, please correct. i) Please notice that the 28" clearance required in the previous code (between the water closet and the lavatory) has been changed to a 60" clearance as shown in the figure. A clear space in front of the water closet measuring 60" wide by 48" in front. Section 11 B-604.3. 1. See the following figures. The restroom is non- compliant, please correct. The door swinging into the restroom must have 60" in the direction of the door swing this can not be obstructed by the lavatory. 30. Show that accessible lavatories comply with the following, per Section 11 B-606: No response. ~30" x 48" clear space is provided in front for forward approach. The clear space may include knee and toe space beneath the fixture. When lavatories are adjacent to a side wall or partition, there shall be a minimum of 18" to the center line of the fixture to the wall. The counter top is :534" maximum above the floor. 'a29" high, reducing to 27" at a point located 8" back from the front edge. A" high x 30" wide and 17" deep at the bottom. Hot water pipes and drain lines are insulated. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. City of Carlsbad 15-0727 4/15/15 Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes L) No El The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. EsGil Corporation In (Partners flip wit/i government for Building Safety DATE: 4/1/15 U,%LICANT ,zl JURIS. JURISDICTION: City of Carlsbad / U PLAN REVIEWER U FILE PLAN CHECK NO.: 15-0727 SET: II PROJECT ADDRESS: 2832 State Street PROJECT NAME: Somewhere in Time - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. LII The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person.. The applicant's copy of the check list has been sent to: EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Mike Freda Telephone #: 619-843-9090 Date contacted: &(-( (by:%~ Email: mfreda760@cox.net Q,MaiI 'j Telephone4 Fax In Person [II REMARKS: By: Doug Moody Enclosures: EsGil Corporation El GA 0 EJ 0 MB El Pc 3/26/15 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad 15-0727 4/1/15 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. These corrections are in response to items not fully addressed or as the result of information provided, the text in bold print indicates the unresolved issue. Corridors shall have fire partition walls of one-hour construction when required by Table 1018.1. Show the locations of the rated corridors on the plans or clearly show compliance with an applicable exception from Section 1018.1.Clearly identify on the plans the 1 hour rated corridor and reference the correct construction detail. Corridors shall have interior door openings protected by tight-fitting smoke and draft control assemblies rated 20 minutes. Table 716.5. Doors shall be maintained self-closing or be automatic closing by action of a smoke detector per Section 909.5.2. Doors shall be gasketed to provide a smoke and draft seal where the door meets the stop on sides and top. Section 716.5.3.1. Please revise the plans to show all doors and openings to the rated corridor to be protected by tight-fitting smoke and draft control assemblies rated 20 minutes doors. 11. Provide a section view of the new soffits. Show: Method of attaching top to the structure and lateral bracing. No information provided. Show height of the soffit from floor, soffit to roof framing or floor framing 12. Provide a section view of all new interior partitions. Show: a) Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing. No information provided. 13. It appears the lighting system is to be altered, please provide complete plans. Please provide the required energy compliance forms. The LTI forms shall be City of Carlsbad 15-0727 4/1/15 signed and imprinted on the plans. The forms are not complete and not consistent with the plans. Please correct. Multilevel lighting controls are required in areas exceeding 100 square feet in area and have a connected lighting load exceeding .5 watts per square foot (Classrooms are .7 watts). Review ES Table 130.1-A for design requirements. Include control placement and design on the floor plans. (AB switching no longer complies for most fixture types.). Nothing is shown on the plans or in the LTI forms. Please correct. Shut-Off Controls: Each floor, each space (not exceeding 5,000 square feet), and each type (general, display, and ornamental) of lighting shall be individually capable of being automatically shut-off when the building is unoccupied. Include the control design. (A percentage of egress lighting is now included in the shut- off requirement). ES 130.1(c). Nothing is shown on the plans or in the LTI forms. Please correct. Automatic daylighting is required in rooms that have 120 watts or more of lighting in the primarily sidelit daylit zone (PSDZ) or rooms having glazing area of 24 square feet or more. On the electrical floor plans, include the daylit locations and control design. Note: Daylite dedicated multilevel control is required if lighting power exceeds .3 watts/square foot. Include the daylighting zones on the floor plans, complete with control design. ES 130.1(d) Note: PSDZ is defined as the area directly adjacent to each vertical glazing, one window head height deep extending into the room with an overall width of the window plus .5 of the window head height on each side. Nothing is shown on the plans or in the LTI forms. Please correct. Occupancy controls are required to shut off all lighting in: Offices 250 square feet or smaller, multipurpose rooms of less than 1,000 square feet, conference rooms, and classrooms of any size. ES 130.1(c)5. Please provide the manufacturer's name and model number of the mandatory automatic controls. Please provide panel schedules, indicate new and existing loads. Please indicate on the plans the location of the electrical panel and detail the required working clearance. Nothing is shown on the plans. Please correct. Provide mechanical plans, showing existing and proposed HVAC equipment, ducts and access to equipment. Please provide mechanical plans showing the location of the ducts and register to ensure there are not any unprotected openings to the rated corridor. 21. When new rooms or spaces are constructed and the existing mechanical system is not to be altered other than relocation of existing duct work; please note or show mechanical ventilation will be provided capable of supplying the minimum rate of outside air required per minute per occupant as shown in Table 402.1 of the CIVIC. Nothing is shown on the plans. Please correct. City of Carlsbad 15-0727 4/1/15 Advisory Note: When alterations, structural repairs or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the following requirements, per Section 11 B-202.4: The area of specific alteration, repair or addition must comply as "new" construction. A primary entrance to the building and the primary path of travel to the altered area, must be shown to comply with all accessibility features. The path of travel shall include the existing parking. Existing toilet and bathing facilities that serve the remodeled area must be shown to comply with all accessibility features. Please address the following comments that are the result of the alterations. Show on the site plan the complying disabled accessible path of travel from the disabled accessible parking spaces to the primary entrance of the tenant space. Please provide detailed plans of the path of travel, indicate slope and width, any pedestrian ramps, curb ramps, walks, handrails, provide dimensioned parking stall details etc. No response. Sales and service counters shall have a portion of the counter which is at least 36" in length with a maximum height of 34 inches. Section 11 B-904.4. 1. No response. 25. Where toilet rooms are provided, each toilet room shall comply with Section 11 B- 213. Where bathing facilities are provided, each bathing room shall comply with Section 11 B-603. Section 11 B-213.2. No response. 29. Show that the water closet is located in a space which provides: A clear space at the water closet in compliance with Section 11 B-604.3.2 (this prohibits any fixtures from encroaching into the clear space at the rear wall). The restroom is non-compliant, please correct. I) Please notice that the 28" clearance required in the previous code (between the water closet and the lavatory) has been changed to a 60" clearance as shown in the figure. A clear space in front of the water closet measuring 60" wide by 48" in front. Section 11 B-604.3. 1. See the following figures. The restroom is non- compliant, please correct. City of Carlsbad 15-0727 4/1/15 __- CENTERLINE CENTERLINE OF OF FIXTURE FIXTURE 18 MIN. }II FLUSH I I Tcn I ACTIVATOR F7%eSET iJ I ON WIDE SIDE V01 c co I II MIN. 30. Show that accessible lavatories comply with the following, per Section 11 B-606: No response. ~30" x 48" clear space is provided in front for forward approach. The clear space may include knee and toe space beneath the fixture. When lavatories are adjacent to a side wall or partition, there shall be a minimum of 18" to the center line of the fixture to the wall. The counter top is :534" maximum above the floor. ~29" high, reducing to 27" at a point located 8" back from the front edge. A high x 30" wide and 17" deep at the bottom. Hot water pipes and drain lines are insulated. 31. Show that grab bars comply with the following, per Sections 11 B-604.5 and 1113- 609: No response. a) Grab bars shall be located on each side or one side and the back of the water closet stall or compartment. b) They shall be securely attached 33" - 36" above the floor, and parallel. c) Grab bars at the side shall be located: Be ~42" long with the front end positioned 24" in front of the stool. Total length of bars at the back shall be ~!36". d) The diameter, or width, of the grab bar gripping surface is ~1 %" but 52", or the shape shall provide an equivalent gripping surface. e) If mounted adjacent to a wall, the space between the wall and the grab bar shall be 11/2'. City of Carlsbad 15-0727 4/1/15 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes Ll No L3 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. U I P EsGil Corporation In PartnersIiip wit/i government for Bui(iing Safety DATE: 3/17/15 YAPPLICANT JURIS. JURISDICTION: City of Carlsbad U PLAN REVIEWER U FILE PLAN CHECK NO.: 15-0727 SET: I PROJECT ADDRESS: 2832 State Street PROJECT NAME: Somewhere in Time - TI LI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdictions codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Mike Freda Telephone #: 619-843-9090 Date contacted :3/(—(by- -qt4-A-1 Email: mfreda760@cox.net EMail t41eph0ne Fax In Person LI REMARKS: By: Doug Moody Enclosures: EsGil Corporation 0 GA 0 EJ 0 MB 0 Pc 3/10/15 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad 15-0727 3/17/15 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 15-0727 OCCUPANCY: M TYPE OF CONSTRUCTION: VB ALLOWABLE FLOOR AREA: SPRINKLERS?: Unknown DATE PLANS RECEIVED BY JURISDICTION: 3/9/15 DATE INITIAL PLAN REVIEW COMPLETED: 3/17/15 JURISDICTION: City of Carlsbad USE: Retail ACTUAL AREA: 1993sf STORIES: 1 HEIGHT: OCCUPANT LOAD: 59 DATE PLANS RECEIVED BY ESGIL CORPORATION: 3/10/15 PLAN REVIEWER: Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2013 CBC, which adopts the 2012 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2012 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. City of Carlsbad 15-0727 3/17/15 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. 2. Provide the names, addresses and telephone numbers of the owner and the responsible design professionals on the Title Sheet. Sec. 107.2. Please clarify the Building Code Data Legend on the Title Sheet. Include the following code information for each building proposed: Occupancy Classification(s) For Mixed Occupancy Buildings, state whether the "no nseparated" or "separated" option was chosen from Sections 508.3/508.4. Description of Use Type of Construction Sprinklers: Yes or No Stories Height Floor Area Occupant Load Please provide an exit analysis plan (may be 8 1/2" x 11" or any convenient size). Show in this analysis the occupant load of each area, the general exit flow patterns (by using arrows), accumulated occupant loads and required exit widths. Section 107.2.3. Egress from a room through an adjoining room (Section 1014.2): a) Egress shall not pass through kitchens, store rooms, closets or spaces used for similar purposes. City of Carlsbad 15-0727 3/17/15 6. Corridors shall have fire partition walls of one-hour construction when required by Table 1018.1. Show the locations of the rated corridors on the plans or clearly show compliance with an applicable exception from Section 1018.1. 7. Corridors shall have interior door openings protected by tight-fitting smoke and draft control assemblies rated 20 minutes. Table 716.5. Doors shall be maintained self-closing or be automatic closing by action of a smoke detector per Section 909.5.2. Doors shall be gasketed to provide a smoke and draft seal where the door meets the stop on sides and top. Section 716.5.3.1. 8. Provide a complete architectural section of the corridor, showing all fire-resistive materials and details of construction for the fire partition walls and roof/ceilings and all penetrations. Section 107.2. 9. Exit signs are required whenever two exits are required. Show all required exit sign locations. Section 1011.1. 10. Please provide notes on the plans to show the suspended ceilings in Seismic Design Categories 0, E & F comply with ASCE 7-05 Section 13.5.6.2.1 as follows: All ceilings shall use a Heavy Duty T-bar grid system. The width of the perimeter supporting closure angle shall be not less than 2 inches. In each orthogonal horizontal direction, one end of the ceiling grid shall be attached to the closure angle. The other end in each horizontal direction shall have a W" clearance from the wall and shall rest upon and be free to slide on a closure angle or a listed assembly. Ceiling areas over 1,000 ft.' must have horizontal restraint wires (typically restraint would consist of four 12 gauge wires splayed 900 to each other and sloped 450 to the horizontal, spaced 12" o.c.). Ceilings without rigid bracing must have 2" oversize trim rings for sprinklers and other ceiling penetrations. 11. Provide a section view of the new soffits. Show: Type, size and spacing of studs. Indicate gauge for metal studs. Specify manufacturer and approval number or indicate "to be ICC approved". Method of attaching top to the structure and lateral bracing. Show height of the soffit from floor, soffit to roof framing or floor framing 12. Provide a section view of all new interior partitions. Show: a) Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing. 13. It appears the lighting system is to be altered, please provide complete plans. Please provide the required energy compliance forms. The LTI forms shall be signed and imprinted on the plans. City of Carlsbad 15-0727 3/17/15 Multilevel lighting controls are required in areas exceeding 100 square feet in area and have a connected lighting load exceeding .5 watts per square foot (Classrooms are .7 watts). Review ES Table 130.1-A for design requirements. Include control placement and design on the floor plans. (AB switching no longer complies for most fixture types.) Shut-Off Controls: Each floor, each space (not exceeding 5,000 square feet), and each type (general, display, and ornamental) of lighting shall be individually capable of being automatically shut-off when the building is unoccupied. Include the control design. (A percentage of egress lighting is now included in the shut- off requirement). ES 130.1(c) Automatic daylighting is required in rooms that have 120 watts or more of lighting in the primarily sidelit daylit zone (PSDZ) or rooms having glazing area of 24 square feet or more. On the electrical floor plans, include the daylit locations and control design. Note: Daylite dedicated multilevel control is required if lighting power exceeds .3 watts/square foot. Include the daylighting zones on the floor plans, complete with control design. ES 130.1(d) Note: PSDZ is defined as the area directly adjacent to each vertical glazing, one window head height deep extending into the room with an overall width of the window plus .5 of the window head height on each side. Occupancy controls are required to shut off all lighting in: Offices 250 square feet or smaller, multipurpose rooms of less than 1,000 square feet, conference rooms, and classrooms of any size. ES 130.1(c)5 Please provide panel schedules, indicate new and existing loads. Please indicate on the plans the location of the electrical panel and detail the required working clearance. Provide mechanical plans, showing existing and proposed HVAC equipment, ducts and access to equipment. Please indicate if the mechanical system will be altered. If so please provide complete plans. Please provide the required MECH forms to show energy compliance. The MECH forms shall be signed and imprinted to the plans. When new rooms or spaces are constructed and the existing mechanical system is not to be altered other than relocation of existing duct work; please note or show mechanical ventilation will be provided capable of supplying the minimum rate of outside air required per minute per occupant as shown in Table 402.1 of the CIVIC. Advisory Note : When alterations, structural repairs or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the following requirements, per Section 11 B-202.4: City of Carlsbad 15-0727 3/17/15 The area of specific alteration, repair or addition must comply as "new" construction. A primary entrance to the building and the primary path of travel to the altered area, must be shown to comply with all accessibility features. The path of travel shall include the existing parking. Existing toilet and bathing facilities that serve the remodeled area must be. shown to comply with all accessibility features. Please address the following comments that are the result of the alterations. 22. Show on the site plan the complying disabled accessible path of travel from the disabled accessible parking spaces to the primary entrance of the tenant space. Please provide detailed plans of the path of travel, indicate slope and width, any pedestrian ramps, curb ramps, walks, handrails, provide dimensioned parking stall details etc. 23. Sales and service counters shall have a portion of the counter which is at least 36" in length with a maximum height of 34 inches. Section 11 B-904.4. 1. 24. Show that the minimum strike edge distances are provided at the level area on the side to which a door (or a gate) swings, per Section 11 B-404.2.4: a) ~:18" at interior conditions. 25. Where toilet rooms are provided, each toilet room shall comply with Section 1113- 213. Where bathing facilities are provided, each bathing room shall comply with Section 11 B-603. Section 11 B-213.2. 26. Show that passageways leading to sanitary facilities have required clear access widths. Show that all doorways have: a) ~32" clear opening. b) A clear area: ~:60" in the direction of the door swing. ~:44" away from the direction of door swing. c) All strike edge clearance dimensions are required to be met (i.e. 18" strike edge distance). 27. Note that the doorways leading to sanitary facilities shall be identified, per Section 11 B-703.7.2.6, as follows: An equilateral triangle 1/4I thick with edges 12" long and a vortex pointing upward at men's rest rooms. A circle 1/4 thick, 12" in diameter at women's rest rooms. City of Carlsbad 15-0727 3/17/15 C) A 12" diameter circle with a triangle superimposed on the circle and within the 12" diameter at unisex rest rooms. The required symbols shall be centered on the door at a height of 58" - 60". Braille signage shall also be located on the wall adjacent to the latch outside of the doorways leading to the sanitary facilities. 28. Show a sufficient space in the toilet room for a wheelchair to enter the room and close the door, per Section 11 B-603.2. The space is required to be: ~!60" diameter. A T-shaped space as shown in Figure 11 B-304.3.2. Doors are not permitted to encroach into this space by more than 12 inches. 29. Show that the water closet is located in a space which provides: A clear space at the water closet in compliance with Section 11 B-604.3.2 (this prohibits any fixtures from encroaching into the clear space at the rear wall). i) Please notice that the 28" clearance required in the previous code (between the water closet and the lavatory) has been changed to a 60" clearance as shown in the figure. A clear space in front of the water closet measuring .60!' wide by 48" in front. Section 11 B-604.3. 1. See the following figures. CENTERLINE CENTERLI OF OF FIXTURE FIXTURE 'IT-18"I I 18 z FLUSH ACTIVAT ON WIDE SIDE - /LJ UI VJATLR CICOCCT co Uj 18 MIN. 30 Show that accessible lavatories comply with the following, per Section 11 B-606: d) ~30" x 48" clear space is provided in front for forward approach. The clear space may include knee and toe space beneath the fixture. City of Carlsbad 15-0727 3/17/15 e) When lavatories are adjacent to a side wall or partition, there shall be a minimum of 18" to the center line of the fixture to the wall. f) The counter top is :534" maximum above the floor. g) ~!29" high, reducing to 27" at a point located 8" back from the front edge. h) ~9" high x 30" wide and 17" deep at the bottom. i) Hot water pipes and drain lines are insulated. 31. Show that grab bars comply with the following, per Sections 11 B-604.5 and 11 B- 609: a) Grab bars shall be located on each side or one side and the back of the water closet stall or compartment. b) They shall be securely attached 33" - 36" above the floor, and parallel. c) Grab bars at the side shall be located: Be ~!42" long with the front end positioned 24" in front of the stool. Total length of bars at the back shall be ~36". d) The diameter, or width, of the grab bar gripping surface is 21%" but :52", or the shape shall provide an equivalent gripping surface. e) If mounted adjacent to a wall, the space between the wall and the grab bar shall be 1W'. 32. Show that at least one water closet fixture shall provide the following, per Section 11 B-604: j) One side of the water closet shall provide 17" - 18" from the centerline of the water closet to the adjacent wall. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of City of Carlsbad 15-0727 3/17/15 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. 4. C City of Carlsbad 15-0727 3/17/15 (DO NOT PAY- THIS IS NOTAN INVOICE) VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: 15-0727 PREPARED BY: Doug Moody DATE: 3/17/15 BUILDING ADDRESS: 2832 State Street BUILDING OCCUPANCY: M BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) TI 1993 City Valuation 51,984 Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code 1cb IBY Ordinance Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance V Type of Review. Comølete Review JRepetiuve Fee E Other qW Repeats Hourly EsGil Fee Structural Only I $409.961 I $266.471 I $229.581 Comments: Sheet I of I macvalue.doc + <4., CITY OF CARLSDD13 A PLAN CHECK REVIEW TRANSMITTAL Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www.carlsbadca.gov DATE:03-12-2015 PROJECT NAME: 'SOMEWHERE IN TIME' T.I. PROJECT ID: CB15-0727 PLAN CHECK NO: 1 SET#: 1 ADDRESS: 2832 STATE ST. APN: 203-181-13-00 VALUATION: $51,984 This plan check review is complete and has been APPROVED by the ENGINEERING Division. By: CG 3-12-15 A Final Inspection by the Division is required Yes / No This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: MFREDA760@COX.NET You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from. all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING . ENGINEERING FIRE PREVENTION 760-602-4610 . 760-602-2750 760-602-4665 Chris Sexton . / Chris Glassen Greg Ryan 760-602-4624 760-602-2784 . 760-602-4663 Chris.Sexton@carlsbadca.gov ChristoDher.GIassen@carIsbadca.gov Gregory.Ryan@carlsbadca.gov Gina Ruiz Linda Ontiveros Cindy Wong - 760-602-4675 760-602-2773 - 760-602-4662 Gina.Ruiz@carlsbadca.gov Linda.Ontiveros@carIsbadca.gov Cynthia.Wonp@carIsbadca.gov Dominic Fier! -- 760-602-4664 Dominic.Fieri@carIsbadca.gov Remarks: Development Services BUILDING PLANCHECK Land Development Engineering CITY OF CHECKLIST 1635 Faraday Avenue 760-602-2750 CARLSD/-%DA QUICK-CHECK/APPROVAL ENGINEERING Plan Check for CBI 5-0727- I Date:03-12-2015 Project Address: 2832 STATE ST. APN: 2031811300 Project Description: T.I. Valuation: $51,984 ENGINEERING Contact: CHRIS GLASSEN Phone: 760-602-2784 El RESIDENTIAL INTERIOR El RESIDENTIAL ADDITION MINOR (420,000.00) El CARLSBAD PREMIER OUTLETS Email: Christopher.Glassen@carlsbadca.gov Fax: 760-602-1052 [j TENANT IMPROVEMENT El PLAZA CAMINO REAL El COMPLETE OFFICE BUILDING [JOTHER: GYM OFFICIAL USE ONLY 1 - ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT BY: CG 3112/15 DATE:03-12-2015 REMARKS: NO ADDITIONAL ENGINEERING FEE Notification of Engineering APPROVAL has been sent to MFREDA760@COX.NET I via EMAIL on 03-12-2015 I E-36 Page 1 of 1 REV 4/30/11 4 ^Ak 041h> CITY OF CARLSBAD PLANNING DIVISION Development Services BUILDING PLAN CHECK Planning Division APPROVAL 1635 Faraday Avenue (760) 602-4610 P29 www.carlsb2dca.20v DATE: 3/11/15 PROJECT NAME: T.I. PROJECT ID: PLAN CHECK NO: CB150727 SET#: ADDRESS: 2832 STATE ST APN: This plan check review is complete and has been APPROVED by the PLANNING Division. By: GINA RUIZ A Final Inspection by the PLANNING Division is required D Yes Z No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: MFREDA760@COX.NET For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING ENGINEERING FIRE PREVENTION 760-602-4610 760-602-2750 760.602-4665 Chris Sexton Chris Glassen Greg Ryan 760-602-4624 Chris.Sexton@carIsbadca.gov 760-602-2784 Christopher.Glassen@carlsbadca.gOv 760-602-4663 Gregory.Rvan@carlsbadca.Eov Gina Ruiz ValRay Marshall Cindy Wong 760-602-4675 Gina.Ruiz@carlsbadca.gov 760-602-2741 VaIRay.MarshaII@carIsbadca.gov 760-602-4662 Cynthia.Wong@carIsbadca.Ov Linda Ontiveros Dominic Fieri 760-602-2773 Linda.Ontiveros@carlsbadca.gov 760-602-4664 Dominic.Fieri@carIsbadca.gov Remarks: / PLAN CHECK UILD nomic D Ui De. Department CITY OF " v' v 1635 Faraday Avenue CARLSDP%D DA TRANSMITTAL Carlsbad CA 92008 0 www.carIsbadca.gov DATE: 03/24/2015 PROJECT NAME: SOMEWHERE IN TIME PROJECT ID: CB150727 PLAN CHECK NO: I SET#: I ADDRESS: 2832 STATE ST This plan check review is complete and has been APPROVED by the FIRE Division. 3y:GR A Final Inspection by the FIRE Division is required 10 Yes No Thu plan chedk review is NOT COMPLETE. Iteiuls missing or incorrect are Ilstdon the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to, mfreda760@cox net You may also have corrections from one or more of the divisions listed below Approval from thesedlvisiOns may be. required prior to the issuance of a building permit. Resubrnitted..plans..shoutd.include corre.ctlons.frorn all divIsions..: : Ior qüestions'or clarificatiOns bnthe attached checklistpleese contact the foflo*ihg reviewer-66 Im. rked: PLANNING . ENGINEERING FIRE PREVENTION 760-602-4610 760-602-2750 760-602-4665 ChrisSexton . Kathleen Lawrence Greg Ryan 760-602-4624 760-602-2741 . 760-602-4663 Chris.Sexton@carlsbadca.gov Kathleen.Lawrence@carlsbadca.gov Greory.Rvan@carIsbadca.ov Gina Ruiz Linda Ontiveros fl Cindy Wong 760-602-4675 760-602-2773 . 760-602-4662 Glna.Rulz@carlsbadca.gov Linda.Ontiveros@carlsbadca.gov Cyntha.Wong@carIsbadcaoy E 0 0• 0 V0 LI DornlnlcFlerl 76O6024864 Dominic.Fieri@carlsbadca4ov Carlsbad Fire Department BUILDING DEPT. COPY Plan Review Requirements Category: TI , COMM Date or Report 0352015 Reviewed by: MASTER TOUCH CONSTRUCTION, INC Address: 982 EL PAJODO PL VISTA CA 92O847O36 Permit # CB15Q727 Job Name: SOMEWHERE IN TIME: 1,993 SF TI Job Add 2832 STATE ST CBAD Please review careftully all comments attached. Conditions: CITY OF CARLSBAD FIRE DEPARTMENT - APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW. Entry: 03/25/2015 By: OR Action: AP Carlsbad Fire Department BLDG DEPT COPY Nan Review Requirements Category: TI , COMM Date of Report: 04-07-2015 Reviewed by: Name: MASTER TOUCH CONSTRUCTION, INC Address: 982 EL PAJODO PL VISTA CA 92084-7036 Permit #: CB 150727 Job Name: SOMEWHERE IN TIME: 1,993 SF TI Job Address: 2832 STATE ST CBAD INCOMPLETE The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval. Conditions: Cond:C0N0008129 [MET] CITY OF CARLSBAD FIRE DEPARTMENT - APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW. Entry: 03/25/2015 By: GR Action: AP 404 h> CITY OF CARLSD/-%D13 PLUMBING, ELECTRICAL, MECHANICAL WORKSHEET B-18 Develooment Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov Building@carlsbadca.gov Project Address: Permit No.: Information provided below refers to work being done on the above mentioned permit only. This form must be completed and returned to the Building Division before the permit can be issued. - Building Dept. Fax: (760) 602-8558 Number of new or relocated fixtures, traps, or floor drains ....................................................... New building sewer line? .........................................................................................Yes No Number of new roof drains? ............................................................................................................... Install/alter water line? ......................................................................................................................... 7. Numberof new water heaters? ......................................................................................................... Number of new, relocated or replaced gas outlets? .................................................................... Numberof new hose bibs? .................................................................................................................. Residential Permits: New/expanded service: Number of new amps: Minor Remodel only: Yes No Commercial/Industrial: Tenant Improvement: Number of existing amps involved/n this project: Number of new amps involved/n this project: New Construction: Amps per Panel: Single Phase ...............................................................Number of new amperes Three Phase.................................................................Number of new amperes Three Phase 480........................................................Number of new amperes________________ Number of new furnaces, A/C, or heat pumps? ............................................................................ _____ New or relocated duct work ..........................................................................Yes No Numberof new fireplaces? ................................................................................................................. Numberof new exhaust fans? ............................................................................................................ Relocate/install vent ............................................................................................................................ Numberof new exhaust hoods? ........................................................................................................ Number of new boilers or compressors? ........................................................... Number of HP f' B-18 Page 1 of 1 Rev. 03/09 cNON.% INDUSTRIAL WASTEWATER DISCHARGE PERMIT WASMAM Date'/'?(' ) SCREENING SURVEY Business Name $0"—e- L Le.- 4.. - 1_( . Street Address 2 57 %4r-,4f_ S Email Address 1-'' €1', i-too @ - ,'-t- PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT: (ON REVERSE SIDE CHECK TYPE OF BUSINESS) Check all below that are present at your facility: Acid Cleaning Ink Manufacturing Nutritional Supplement! Assembly Laboratory Vitamin Manufacturing Automotive Repair Machining I Milling Painting I Finishing Battery Manufacturing Manufacturing Paint Manufacturing Biofuel Manufacturing Membrane Manufacturing Personal Care Products Biotech Laboratory (i.e. water filter membranes) Manufacturing Bulk Chemical Storage Metal Casting I Forming Pesticide Manufacturing I Car Wash Metal Fabrication Packaging Chemical Manufacturing Metal Finishing Pharmaceutical Manufacturing Chemical Purification Electroplating (including precursors) Dry Cleaning Electroless plating Porcelain Enameling Electrical Component Anodizing Power Generation Manufacturing Coating (i.e. phosphating) Print Shop Fertilizer Manufacturing Chemical Etching I Milling Research and Development Film/ X-ray Processing Printed Circuit Board Rubber Manufacturing Food Processing Manufacturing Semiconductor Manufacturing Glass Manufacturing Metal Powders Forming Soap / Detergent Manufacturing Industrial Laundry Waste Treatment.! Storage SIC Code(s) (if known): Brief description of business activities (Production/ Manufacturing Operations):______________ Description of operations generating wastewater (discharged to sewer, hauled or evaporated): Estimated volume of industrial wastewater to be discharged (gal/ day): List hazardous wastes generated (type/ volume): Date operation began/or will begin at this location: Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authority? Yes No If yes, when: Site Contact I't &t 1roL Title CL 0IJ r__11_ do, Z / Signature Phone No. (Ce ENCINA WASTEWATE AUTHORITY, 6200 Avenida Encinas Carlsbad, CA 92011 (760) 438-3941 FAX: (760) 476-9852 10 V 1%VE IS p SAN DIEGO REGIONAL I'M," HAZARDOUS MATERIALS QUESTIONNAIRE OFFICE USE ONLY UPFP# HV#__________________ BP DATE I I Business Name j..j,k/1bu'A Business Contact C-°,f -r-.. tk. vtd' Telephone # ( tl)4o Project Address city SJrt..SrtJ StateZip Code I APN#I 7Jt Mailing Address City tsLn~ State CA Zip Code l2Jot) I I Plan File# Project Contact Telephone # 4 The following questions represent the facility's activities, NOT the specific project description. PART I: FIRE DEPARTMENT - HAZARDOUSMATERIALSDIVISION:OCCUPANCY CLASSIFICATION: Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Facility's Square Footage (including proposed project): Occupancy Rating: 1. Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 13. Corrosives 2. Compressed Gases 6. Oxidizers 10. Cryogenics 14. Other Health Hazards 3. Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials 15. None of These. 4. Flammable Solids 8. Unstable Reactives 12. Radioactives a answer to any CA 92123. (858) 505-6700 prior to the issuance of a building permit. FEES ARE REQUIRED. Project Completion Date: Expected Date of Occupancy: _/.............j 0 CalARP Exempt YES N9( (for new construction or remodeling projects) / 1. 0 ii:, Is your business listed on the reverse side of this form? (check all that apply). Date Initials 0 0 Will your business dispose of Hazardous Substances or Medical Waste in any amount? 21 Will business handle Hazardous Substances in 0 CaIARP Required your store or quantities equal to or greater than 55 gallons, 500 pounds 200 cubic feet, or carcinogens/reproductive toxins in any quantity? Date Initials 0 4' Will your business use an existing or install an underground storage tank? 0 Will your business store or handle Regulated Substances (CalARP)? 0 CaIARP Complete 0 142 Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? 0 'J Will your business store petroleum in tanks or containers at your facility with a total storage capacity equal to Date Initials or greater than 1,320 gallons? (California's Aboveground Petroleum Storage Act). PARTIII:SANDIEGOCOUNTYAIRPOLLUTIONCONTROLDISTRICT: If the answer to any of the questions below is yes, applicant must contact the Air Pollution Control District (APCD), 10124 Old Grove Road, San Diego, CA 92131-1649, telephone (858) 586-2600 prior to the issuance of a building or demolition permit. Note: if the answer to questions 4 or 5 is yes, applicant must also submit an asbestos notification form to the APCD at least 10 working days prior to commencing demolition or renovation, except demolitionorrenovation of residential structures of four units or less. Contact the APCD for more information. YES ZNO 1. 0 Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant? (See the 1APCD factsheet at http://www.sdaocd.oro/infolfacts/permits.pdf, and the list of typical equipment requiring an APCD permit on the reverse side J of this from. Contact APCD if you have any questions). 0 I ,(ANSWER ONLY IF QUESTION 1 I YES) Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)? / (Search the California School Directory at htto:/Iwww.cde.ca.pov/re/sdl for public and private schools or contact the appropriate school district). 0 / Has a survey been performed to determine the presence of Asbestos Containing Materials? 0 /ill there be renovation that involves handling of any friable asbestos materials, or disturbing any material that contains non-friable asbestos? 0 V Will there be demolition involving the removal of a load supporting structural member? Briefly describe business activities: Briefly describe proposed project: I declare under penalty of perjury that to the best of my knowledge and belief the responses made herein are true and correct. Name of Owner or Authorized Agent Signature of Owner or Authorized Agent Date FOR OFFICIAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION:_____________________________________________________________________ BY: DATE: EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTYHMD* APCD COUNTY-HMO APCD COUNTY-HMD APCD A stamp in mis box oniv exempts businesses Trom completing or updating a hazardous materials business Pl. Otner permitting requirements may still apply. HM-9171 (02/11) County of San Diego - DEH - Hazardous Materials Division C8150727 2832 STATE ST SOMEWHERE IN TIME: 1,993 SF TI RETAIL TO SAME Final Inspection required by. Plan Q CM&I SW OISSUEC Approved In BUILDING IV 3jI 116 ENGINEERING 3Ii1)s PLANNING FIRE Expedite? /i DIGifALFILES Required? Y N: HasMat APCD - Health - - Forms/Fees Sent Encina Fire - IL HazHeaIthAPCD PE&M School - - Sewer amagalt Stormwater 6/itlis r-i- /'6 Special Inspection \ CR): Y N LandUse: Qensity. ImpArea 1 ' PFF: Y / N Comments Date Building A11711ci LJ Planning I Engineering I Fire 47