Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2122 SUBIDA TER; ; CBR2017-0604; Permit
(,C* of Carlsbad Residential Permit Print Date: 05/22/2018 Permit No: CBR2017-0604 Job Address: 2122 Subida Ter Permit Type: BLDG-Residential Work Class: Alteration Status: Closed - Finaled Parcel No: 2164811300 Lot #: Applied: 03/27/2017 Valuation: $84,845.19 Reference #: Issued: 05/17/2017 Occupancy Group: Construction Type: Permit Finaled: #1 Dwelling Units: Bathrooms: Inspector: AKrog Bedrooms: Orig. Plan Check #: Final Plan Check #: Inspection: 5/22/2018 9:49:07AM Project Title: Description: HUYNH: 1ST FLOOR REMODEL OF 588 SF //2ND FLOOR REMODEL OF 731 SF 11115SF 2ND STORY ADDITION (ENCLOSING DECK AREA)// NEW 200 SF BALCONY Applicant: Owner: JUAN QUEMADO COOWNER GENE LEE & KATHERINE HUYNH BUILDING PERMIT FEE $2000+ $561.05 BUILDING PLAN CHECK FEE (BLDG) $383.43 MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL $52.00 PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL $80.00 5B1473 BUILDING STANDARDS FEE $4.00 STRONG MOTION-RESIDENTIAL $11.03 SWPPP INSPECTION FEE TIER 1 - Medium BLDG $232.00 SWPPP PLAN REVIEW FEE TIER 1- MEDIUM $55.00 Total Fees: $1,378.51 Total Payments To Date: $1,378.51 Balance Due: $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. 1635 Faraday Avenue, Carlsbad, CA 92008-7314 1 760-602-2700 1 760-602-8560 f I www.carlsbadca.gov ITHE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: I2LANNING 0 ENGINEERING 1t'UILDING 0 FIRE 0 HEALTH IJ HAZMATIAPCD 4rC1Y of Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 Plan Check No. C RdO 1 Est. Value 4f., a i . (or, r, n %i Ph: 760-602-2719 Fax: 760-602-8558 email: buildingcarlsbadca.gov Ccrfrlsbad Plan Ck. Deposit 3t3 i43 Date ? /t7 /1 7 ISWPP ___________ P www.carlsbadca.gov JOB ADDRESS 2122 SUBIDA TERRACE, CARLSBAD, CA 92009 I SUITE#/SPACE#/UNIT# I I AP I - Z/ti - / CT/PROJECT# LOT# E C C OF UNITS C BEDROOMS I # BAThROOMS CONSTR. TYPE CON OCC. GROUP I 1PHAS I 4 I 1TENANTBUSINESSNAME RES I DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) 1. 1ST FLOOR - Leveling floor by removing two stair steps, removal of wall separating kitchen and dinning room, add new stronger load bearing beam, no grading 2. 2ND FLOOR - Adding one bathroom, new windows, and redesigning the locations of master bedroom and two other rooms. Extending living space ;f by eliminating 2o patio k PDI1"KN 115 1 4 p- Czat si' LEXISTINGUSE sidential I PROPOSED USE Residential I GARAGE (SF) I - PATIOS (SF) 0 I DECKS (SF) I I 200 I'ESL FIREPLACE 111 NoE lAIRCONDITIONING I YES[ ]NO[—]: I FIRE SPRINKLERS YESENOE APPLICANT NAME GENE LEE & KATHERINE YNH Prinary Contact HU PROPERTY OWNER NAME SAME ADDRESS 2122 SUBIDA TERRACE ADDRESS CITY STATE ZIP CARLSBAD CA 92009 CITY STATE ZIP PHONE 858-774-7330 FAX I PHONE ____________________________________________________ FAX EMAIL gene5Iee(yahoo.com; khuynh_98(yahoo.com EMAIL DESIGN PROFESSIONAL JUAN QUEMADO CONTRACTOR BUS. NAME OWNER/BUILDER ADDRESS 875 BOWSPRIT ROAD ADDRESS CITY STATE ZIP CHULA VISTA CA 91914 CITY STATE ZIP PHONE 619-921-4433 I FAX PHONE IFAX I EMAIL juanquemadocyahoo.com EMAIL ________________________ STATE LIC. C STATE LiCe BUS. LIC.# www.a-e-studio.com I 1CLASS 1CITY (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair anystructure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law fChapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a ,,i,,il nnnaitv of not morn than fiva hundred dollars 1550011 Workers' Compensation Declaration: I hereby offinn under penalty of perjury one of the following declarations: RI have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co._____________________________________________________________ Policy No. Expiration Date This section need not be completed if the permit is for one hundred dollars ($100) or less. EZICertificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), In addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. Af CONTRACTOR SIGNATURE 0 AGENT DATE 000130000011001) Q9i1O®() I hereby affirm that lam exempt from Contractor's License Law for the following reason: IZI I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). [J I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). [] I am exempt under Section _____________Business and Professions Code for this reason: 1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement DYes DNo 2.1 (have! have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name address! phone! contractors' license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name! address! phone! contractors' license number): 5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name! address! phone ltype of work): ii I,IJ I A []AGENT DATE PROPERTY OWNER SIGNATURE j4t'f)L" (®(!@?@ iCO00 O®() 900 Q(!JO®Oi)® (POTGANVO 0131117 1 Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 Yes 0 No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? DYes 0 No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 13 Yes Cl No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. c®!)o®ai (@()®O)@a@9139(99 I hereby affirm that there is construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lenders Name Lender's Address O? OO(17O®() IcertifythatI have read the application and statethatthe above information isconectand thatthe information on the plans isaosurate. IagreetocempIywithall Cityordlnancesand State laws reIatingtebuiIdingconstructIon. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST All. LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 50' deep and demolition or construction of structures over 3 stories in height EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced fora period of 180 days (Section 106.4.4 UnifOrm Building Code). ..'APPLICANT'S SIGNATURE DATE 3-5'7 -/ '1 LOU PE Permit Type: BLDG-Residential Application Date: 03/27/2017 Owner: COOWNER GENE LEE & KATHERINE HUYNH Work Class: Alteration Issue Date: 05/17/2017 Subdivision: CARLSBAD TCT#75-07 Status: Closed - Finaled Expiration Date: 06/27/2018 Address: 2122 Subida Ter Carlsbad, CA 92009-7926 IVR Number: 2762 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary inspector Reinspection Complete Checklist Item COMMENTS Passed BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes May 22, 2018 Page 7of7 Permit Type: BLDG-Residential Application Date: 03/27/2017 Owner: COOWNER GENE LEE & KATHERINE HUYNH Work Class: Alteration Issue Date: 05/17/2017 Subdivision: CARLSBAD TCT#75-07 Status: Closed - Finaled Expiration Date: 06/27/2018 Address: 2122 Subida Ter Carlsbad, CA 92009-7926 lVR Number: 2762 Scheduled Actual inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date Checklist Item COMMENTS Passed BLDG-Building Deficiency Prefinal list left with contractor No BLDG-Plumbing Final No BLDG-Mechanical Final No BLDG-Structural Final No BLDG-Electrical Final No 0411612018 0411612018 BLDG-Final 055115.2018 Cancelled Andy Krogh Reinspection Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Prefinal list left with contractor No BLDG-Plumbing Final No BLDG-Mechanical Final No BLDG-Structural Final No BLDG-Electrical Final No 0411812018 0411812018 BLDG-Final 055348-2018 Failed Chris Renfro Reinspection Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Check inspection card for corrections No BLDG-Plumbing Final - No BLDG-Mechanical Final No BLDG-Structural Final No BLDG-Electrical Final No 0511712018 0511712018 BLDG-Final 058353-2018 Cancelled Andy Krogh Reinspection Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Check inspection card for corrections No BLDG-Plumbing Final No BLDG-Mechanical Final No BLDG-Structural Final No BLDG-Electrical Final No 0512112018 0512112018 BLDG-Final 058597-2018 Cancelled Andy Krogh Reinspection Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Check inspection card for corrections No BLDG-Plumbing Final No BLDG-Mechanical Final No BLDG-Structural Final No BLDG-Electrical Final No 0512212018 0512212018 BLDG-Final 058736.2018 Passed Andy Krogh Complete Inspection May 22,2018 1 Page 6of7 Permit Type: BLDG-Residential Application Date: 03/27/2017 Owner: COOWNER GENE LEE & KATHERINE HUYNN Work Class: Alteration Issue Date: 05/17/2017 Subdivision: CARLSBAD TCT#75-07 Status: Closed - Finaled Expiration Date: 06/27/2018 Address: 2122 Subida Ter Carlsbad, CA 92009-7926 IVR Number: 2762 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete 1012412017 1012412017 BLDG-17 Interior 038463.2017 Failed Andy Krogh Reinspection Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Incomplete No 1012612017 1012612017 BLDG-17 Interior 038609.2017 Partial Pass Andy Krogh Reinspection Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Incomplete No Checklist Item COMMENTS Passed BLDG-Building Deficiency Partial as noted on card No 10/31/2017 10/3112017 BLDG-17 Interior 039125.2017 Passed Andy Krogh Lath/Drywall 11/09/2017 11109/2011 BLDG-27 Shower 040068.2011 Passed Andy Krogh Pan/Tubs 11/1412017 11/14/2017 BLDG-17 Interior 040404.2017 Cancelled Andy Krogh Reinspection Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Partial as noted on card No 11116/2011 11/16/2011 BLDG-17 Interior 040723-2017 Passed Andy Krogh Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Shower lath Yes 12/2812017 12128/2011 BLDG-11 044557.2017 Failed Andy Krogh Reinspection Foundation/Ftg/Pier 5 (Reber) Incomplete Complete Complete Complete Complete Complete Checklist Item COMMENTS - Passed BLDG-Building Deficiency Correct rebar size and clearance No 12/29/2011 12/29/2011 BLDG-I1 044676.2017 Passed Andy Krogh Complete Foundation/Ftg/Pler S (Rebar) ChecklistItem COMMENTS Passed BLDG-Building Deficiency One pic new footing for new steel column Yes with special inspection report 03/16/2018 03/16/2018 BLDG-Final 051988.2018 Failed Andy Krogh Reinspection Complete Inspection May 22, 2018 Page 50f7 Permit Type: BLDG-Residential Application Date: 03/27/2017 Owner: COOWNER GENE LEE & KATHERINE HUYNH Work Class: Alteration Issue Date: 05/17/2017 Subdivision: CARLSBAD TCT#75-07 Status: Closed - Finaled Expiration Date: 06/27/2018 Address: 2122 Subida Ter Carlsbad, CA 92009-7926 IVR Number: 2762 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete 09/1412017 0911412017 BLDG-84 Rough 034664-2017 Partial Pass Andy Krogh Reinspection Incomplete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Questions about electrical and new panel Yes BLDG-Building Deficiency Engineers fix received, Ok to patch stucco Yes at windows south wall BLDG-14 Requires structural engineer to look at No Frame-Steel-Bolting-Welding sagging floor in second story overhanging, (Decks) staging about 2+" in corner, Add additional walls and connectors per plans BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers 09/19/2017 09/19/2017 BLDG-18 Exterior 035147-2017 Passed Andy Krogh Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Rear windows -_- Yes 09/26/2017 09/26/2017 BLDG-33 Service 035837-2017 Passed Andy Krogh Change/Upgrade 09/27/2017 09/27/2017 BLDG-84 Rough 035959-2017 Failed Andy Krogh Reinspection Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-14 Add straps at overbore conditions No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Add outlets kitchen and second floor alcove No at stairway BLDG44 Run ducting for master bathroom exhaust No Rough-Ducts-Dampers fans 09/28/2017 09/28/2017 BLDG-84 Rough 036172-2017 Passed Andy Krogh Combo(14,24,34,44) Checklist Item COMMENTS Passed Complete Complete Complete BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers 10/10/2017 10/10/2017 BLDG-16 Insulation 037130-2017 Passed Andy Krogh Yes Yes Yes Yes Yes Complete May 22, 2018 Page 4of7 Permit Type: BLDG-Residential Application Date: 03/27/2017 Owner: COOWNER GENE LEE & KATHERINE HUYNH Work Class: Alteration Issue Date: 05/17/2017 Subdivision: CARLSBAD TCT#75-07 Status: Closed - Finaled Expiration Date: 06/27/2018 Address: 2122 Subida Ter Carlsbad, CA 92009-7926 IVR Number: 2762 Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date 0810812017 0810812017 BLDG-14 030882.2017 Partial Pass Andy Krogh Reinspection Incomplete Frame/Steel/Bolting/ Welding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Exterior sheeting on street walls Yes BLDG-24 030881.2017 Failed Andy Krogh Reinspection Complete RoughlTopout Checklist Item COMMENTS Passed -\ BLDG-Building Deficiency Not filled No 0811512017 0811512017 BLDG-24 031724-2017 Passed Andy Krogh Complete RoughlTopout 0812112017 0812112017 BLDG-34 Rough 032314.2017 Failed Andy Krogh Reinspection Complete Electrical Checklist Item COMMENTS Passed BLDG-Building Deficiency All trades to be complete for a combo No inspection 0812512017 08125/2017 BLDG-18 Exterior 032886.2017 Partial Pass Andy Krogh Reinspection Incomplete lathlprywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Front of house addition and rear sliding Yes door BLDG-84 Rough 032832.2017 Failed Andy Krogh Reinspection Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers 09/01/2017 09/01/2017 BLDG-12 Steel/Bond 033611.2017 Beam Checklist Item Not ready for combo 8/25/2017 No Engineers fix received. Ok to patch stucco Yes at windows south wall Requires structural engineer to look at No sagging floor in second story overhanging, staging about 2+" in corner, Add additional walls and connectors per plans No No No Passed Paul Burnette COMMENTS Passed Complete BLDG-Building Deficiency - Yes May 22,2018 Page 3of7 Permit Type: BLDG-Residential Application Date: 03/27/2017 Owner: COOWNER GENE LEE & KATHERINE HUYNH Work Class: Alteration Issue Date: 05/17/2017 Subdivision: CARLSBAD TCT#75-07 Status: Closed - Finaled Expiration Date: 06/27/2018 Address: 2122 Subida Ter Carlsbad, CA 92009-7926 IVR Number: 2762 Scheduled Actual Date Start Date Inspection Type Inspection No. - -- Inspection Status Primary Inspector Reinspection Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready for combo No BLDG-14 Requires structural engineer to look at No Frame-Steel-Bolting-Welding sagging floor in second story overhanging, (Decks) staging about 2+" in corner, Add additional walls and connectors per plans BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers 0711412017 07/14/2017 BLDG-84 Rough 028848.2017 Failed Andy Krogh Reinspection Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Engineers fix received, Ok to patch stucco Yes at windows south wall BLDG-Building Deficiency Not ready for combo No BLDG-14 Requires structural engineer to look at No Frame-Steel-Bolting-Welding sagging floor in second story overhanging, (Decks) staging about 2+" in corner, Add additional walls and connectors per plans BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers 07/27/2017 07/27/2017 BLDG-21 029933.2017 Failed Chris Renfro Reinspection Complete Underground/Underf loor Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready. Call for re-inspection of rough No plumbing 08/04/2017 08/04/2017 BLDG-84 Rough 030752.2017 Cancelled Paul Burnette Reinspection Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready for combo No BLDG-Building Deficiency Engineers fix received, Ok to patch stucco Yes at windows south wall BLDG-14 Requires structural engineer to look at No Frame-Steel-Bolting-Welding sagging floor in second story overhanging, (Decks) staging about 2+" in corner, Add additional walls and connectors per plans BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers May 22, 2018 Page 2 of Permit Type: BLDG-Residential Application Date: 03/27/2017 Owner: COOWNER GENE LEE & KATHERINE HUYNH Work Class: Alteration Issue Date: Q5/1712017 Subdivision: CARLSBAD TCT#75-07 Status: Closed - Finaled Expiration Date: 06/27/2018 Address: 2122 Subida Ter Carlsbad, CA 92009-7926 IVR Number: 2762 Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date 05/1712017 0511712017 BLDG-SW-Pre-Con 023751-2017 Passed Andy Krogh Complete 05/18/2017 05/18/2017 BLDG-23 023756-2017 Passed Andy Krogh Complete Gas/Test/Repairs 0512212017 05/2212017 BLDG-31 024097-2017 Passed Andy Krogh Complete Underground/Condu It - Wiring 05/2412017 05/24/2017 BLDG-11 024252-2017 Partial Pass Andy Krogh Reinspection Incomplete Foundation/Ftg/Pier S (Reber) Checklist Item COMMENTS Passed BLDG-Building Deficiency New slab only, no column footings at this Yes time 06/0212017 06102/2017 BLDG-84 Rough 025152-2017 Failed Andy Krogh Reinspection Complete Combo(14,24,34.44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready for combo No BLDG-14 'Requires structural engineer to look at No Frame-steel-Bolting-Welding sagging floor in second story overhanging, (Decks) staging about 2+" in corner, Add additional walls and connectors per plans BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers 06105/2017 06/05/2017 BLDG-11 025427-2017 Passed Andy Krogh Complete Foundation/FtglPier S (Reber) Checklist Item COMMENTS Passed BLDG-Building Deficiency 06/06/2017 06/06/2017 BLDG-15 025442-2017 Roof/ReRoof (Patio) 07/06/2017 07/06/2017 BLDG-84 Rough 028027-2017 Combo(I4,24,34,44) 4pc column footings, 2 interior, 2 exterior Passed Andy Krogh Failed Andy Krogh Yes Complete Reinspection Complete May 22, 2018 Page lot 7 Special Inspection Agency! Construction Materials Testing Laboratory Final Report City of Carlsbad, Inspection Services Division Planning & Development Review 1635 Faraday Avenue. Carlsbad, CA 92008 I *1w i ul, IpM DATE: 12/28/2017 TO Building Official, City of Carlsbad Inspection Services, Planning and Development Review ,.. 1635 Faraday Avenue Carlsbad, CA 92008 SUBJECT: Satisfactory completion of work requiring Special Inspection 'PERMIT NUMBER: C82017-0604, PROJ ECT ADDRESS: 2122 Subida Terrace, CarIsbad,Ca.''—...... <-'•x ,5:" '- -:-' L 0 SPECIAL INSPECTION INSPECTION AGENCY: Ghotrideilnc. ADDRESS: POB 2009 El x..1"i9 SPECIAL INSPECTOR'S NAME: R. Motsinger.''v (Each special inspector'is ecuiredio'mplete and submit this Final Report SPECIAL INSPECTOR'S tERTIFICATION NUMBER: San Diego # 7281 EXPIRATIOND TE: 12/2019 CONSTRUCTION MATERALSESTING WAS PERFORMED BY:,7. j •.', TESTING LABORAT,ORY/AGENCY.-N/A... V -\4, ,V -- ADDRESS N/A/ :4( 'I RESPONSIBLE MANAGINGCIVIL ENGINEER OF-THE JESTING LABORATORY: .N/A'-- -. I I •fl (' .' '.". • .. i STATE OF CALIFORNIA REGISTRATION NUMBER N/A EXPIRATION DATE 1N/A, ;c COMMENTS: Comoleted Soecial Insoection of Shon Weldina of Col mn on oro,ect. .....- J I declare under penalty of perjury,that, to the best of my knoñledg€o'r as noted ãbbve, all the work requiring .. 'J -' E&AJ, \Li '1 special inspection and/or mteriaIsampling ah&testingfor the strictüre or structués constructed under the subject permit is in\sLbstantial nformnce wi thAe pproved plans and construction documentc, the approved inspection and testihg'program'nd the appIicableworkmàhstiip pr'ovisions of -the California'Building Code as amended by City of Carlsbad, Signature: 1he.?__ •,...:':Y'/" (Special Inspector) Executed on: 12/28/2017, NA - J t•.) (Responsible Marging civil Engineer) F E xécutedon: N/A SS T SPECIAL INSPECTION SERVICES WERE P This is not a government form. The State, County and City seals only signifies, the Inspections are conducted under Federal, State. County and City Codes (2007 C.B.CJ. This document Is not used for advertising, marketing or promotions. This document is used to convey compliance with the Code. -'•--p :- NPDES NSPECTION REF;ORT Building Division Pursuant to CMC 15.12.100 Date 5/ /oi7 I Address:Inspector Timeice Time Permit#: CB#:Rj2DIj4'h1 SW#: Inspection Type a 0 Follow Up Rainfall 0 Rain Expected at _% chance I High Priority I 0 YES Pre-Event 0 Complaint 0 Rainfall since last inspection = Focus Area I..t4o BMP IMPLEMENTATION AND COMPLIANCE BMP COMPLIANCE ACTIVITY U, CORRECTIVE ACTI REQUIRED ON ..' Are inactive slopes properly stabilized? M 0 Properly stabilize slopes and unprotected areas. 1611 Are areas flatter than 3:1 covered or protected? 's .0 Provide additional erosion contrbl. ]615 Are gravel bags, waddles, silt fences, and other erosion - control BMPs in place and functioning properly? - Repair/replace erosion control BMPs 611 Are landscaped and natural areas protected from erosion? - - % Replace broken rock/sand 611 Do basins appear to be maintained as required? 's 0 Desiltation/retention basin(s) requires maintenance. 611 Are perimeter control BMPs maintained? - 4' Provide, repair, or replace perimeter controls. 611 Is the entrance stabilized to prevent tracking? - - 2l' Prevent sediment tracking onto street. 615 Are storm drain inlets protected and BMPs maintained? \ - ' Provide additional protection at storm drain inlets. - 612 ' Clean in and around storm drains. 611 Has sediment accumulated on impervious surfaces? - jl' Impervious surfaces need to be swt. 606 Are dumpsters and trash receptacles covered? Remove trash and debris from projet site. 616 - jj/ Provide cover for dumpster and trash receptacles. 617 618 Has trash and debris accumulated throughout the site? s Are stockpiles and spoils protected from runoff? 7 Protect/Cover materials stored outdoors. 606 Are all material and equipment handling, \ 0 Discard unusable equipment and ma(erials. 611 storage and repair areas clean and maintained? - - - 0 Provide spill kit(s) in equipment storag areas. 614 Are spill kits provided onsite? - - 0 Immediately clean up spills and leaks. 618 Are washout areas maintained and protected? 0 Maintenance required for washout areas. 606 Were any discharges observed during the inspection? = 0 Immediately discontinue washing or hosing. 606 Is the SWPPP wall map up to date and accurate? \ 0 Update the SWPPP and/or wall map. 611 Was the SWPPP or Erosion Control Plan - - - 0 Provide additional SWPPP documentation. 613 615 reviewed during this inspection? - - \ 0 Train staff on pollution prevention. Are portable restrooms located away from the storm drain and on level ground? 0 Relocate portable restrooms away from storm drains. 616 Do portable restrooms have secondary containment? - - 0 Provide secondary containment for portable restrooms. 617 Are BMPs stockpiled for emergency deployment? - 4' Provide additional emergency BMPs. 611 Other: Change Priority 0 High 0 Med 0 Low Change Status 0 QSP Present Yes No Inactive 0 Completed I During Inspection I I I ,Commelft +-b A0 gel VIOLATIONS WERE NOTED DURING THE INSPECTIO14 I/ 0 15.12.050 Prohibited Discharge (606) . O .15.12.060 Discharge in Violation of Permit (606) 15.16.130(A) Responsibilities of Permittee (611-618) 15.16.170(B) Unlawful Acts (615) . 15.12.080(E) Reduction of Pollutants - Construction (611) 6.08.030 Receptacles Generally (616) ) 15.12.090 Storm Water Conveyance System Protection (612) 6.08.045 Cleanliness of Solid Waste Receptacles (617) O 15.12.110 Failure to Implement Corrective Actions (613) 1 9 6.08.050 Solid Waste Receptacles to be Kept Covered (618) 0 15.12.120 Containment, cleanup, and notification of spills (614) 0 6.08.090 Unlawful Placement of Solid Waste (619) 15.16.120(7) Storm Damage Precautions (611-618) 0 Other Nt __________________________________ THIS SERVES AS A WARNING NOTICE. Implement corrective actions by 7/2OI7 . A City inspector will return on or after this date to verify that corrective action BMPs were implemented as(requifed. If you have any questions or comments, please contact your inspector. Inspecter Si nature* Received By - Please Print I I Re aived y - Signature 0 Mailed 7 Date / White: Building -. . Yellow: Job Site - Ki ng Inspection Services ICC - AC DesrnoiidrnkIng@gt111 corn 9480 Rockcrest Lane, Lakeside,CA,92040 .' . . . . (619)261-9022 . . DLLYOSERVATION REPORT Job Address . 2fl122 Jt47\ Cl4 VCntul No. 2 U'? 0psuud by. an File No. P am lrJt?A C' Architect; Mitriai licscnptton . /I4 :j iugineer Obsetvcrs Name % LiAa 4-' / .. Contractor JZ61tbt) Samples x .:._ Quantity . . but)ftirac1Or .. . . / . DESCRIPTION OF WORK OBSERVED . . DATE (DAY) ,Y 40 . ... .. S/}iJ $-r4' L*k(:k 4r fr RECJVEO MAY 24201? CtTY O ,RLSbAD jDlDlVSON . .._.. ATTORNEY-S FEES- If any action at law or inequity is brouhuo enforce or interpret the temis of this contract; the prevailing patty shall be enthIecItoreasonableaunmeys fees, cgs( und n ccray disburcrnctns in adclitiuii to any other relief to which such pjty moy bu cntitIc, .. . . . . TIMEN T1MFOtTl MIN.EE DAOXIEE O.T. D.T. HItS. 0201 .. . AU obscrnti ms based on antiuimwn fee for up to 4 hours ora daily fee for4 toll hours. Any obs avations eucndii1past noon will be based on a daily lee. Over S how' and Saturday th is an and a half. Mir I'luitus and Sunday Is double time. Appmcd (7 C)n-Site Reprcscntatim, . 'Ihereby certify, that it the time olthis report. I have ohs cd nil of the abo'.c reported woit, unless âtheiwisenotcd. To the best of my kauwledgc and bc11e1 Ihavc found this.worIt to, comply with the approved plans, spectF.cadons and applicable set-don(s) of the building code as applies to thinjuosdiclama Where the project is located. This report cannot he construedli, bra mnrncr.daxicnr of work-. of any rmatire. tobeperfonned. ftc Owner. or a succea!or in interest, sballhold hrsnzkss. King Special inspections fiw any ws4 all legal proceedings of any nature whalsoeva. that, are :eiatedo tlw.oh Ott senices • Signarure of Observer 1i (cc " Specialty RcrinwredNo. Agency CITY OF. CARLSBAD CBR2017-0604 APR 49 2017 \J CITY OF CARLSBAD SPECIAL INSPECTION AGREEMENT B-45 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.cärlsbadca.gov In accordance with Chapter 17 of the California Building Code the following must be completed when work being performed requires special inspection, structural observation and construction material testing 'roject/Permit: - O(O' Project Address:_ TH)d SECTION MUST BE COMPLETED BY THE PROPERTY OWNERIAUTHORIZED AGENT. Please check if you are Owner-Builder ' (If you checked as owner builder you must also complete Section B of this agreement) Name: (Please printl Y.A. 1L4 t41 V. Mailing Address: '. C.A °*W09 Email3 ( ___ Phone:________________ I am: Øroperty Owner OProperty Owner's Agent of Record DArchitect of Record DEngineer of Record State of California Registration Number Expiration Date:___________________ AGREEMENT: I, the undersigned declare under penally Of perjury under the laws of the State of California, that I have read, understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections structural observations, construction materials testing and off site fabrication of building components, as prescribed in the statement of special inspections noted on the approved plans and, as required by the California Building Code. Signature: . . . Date:.____________________________ CONTRACTOR'S STATEMENT OF RESPONSIBILITY (07CBC, Ch 17, Section 1706). This section must be completed by the contractor I builder! owner-builder. Contiactor's Company Name: Please check if you are Owner-Builder cr" -er Name: (Please prin __________________________________________________ 1 Mailing Address: ZI' eoA. 1t&4CA. c-. 41 -M049 Email:_ i a 01 A_e _ Phone:_________________ State of California Contractor's License Number: Expiration Date: I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on the approved plans; I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the building official; I will have in place procedures for exercising control within our (the contractors) organization, for the method and frequency of reporting and the distribution of the reports; and I certify that I will have a qualified person within our (the contractors) organization to exercise such control c11 Wi 7 8-45 Page 1 of 1 Rev. 08/11 EsGil Corporation In Partners flip wit/i government for(Building Safety DATE: May 11, 2017 U tICANT URIS. JURISDICTION: c?Y0FCARLSBAU) ,/'U PLAN REVIEWER U FILE PLAN CHECK NO.: CBR2017-0604 SET: III PROJECT ADDRESS: 2122 SUBINA TERR. PROJECT NAME: ADDITION, REMODEL, AND NEW PATIO COVER FOR HUYNH-LEE RESIDENCE The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: #: - 0 Date contacted: - (by ) Email: Mail Telephone Fax In Person IZI REMARKS jtyio place soil—stamp By: Rich Moreno Enclosures: EsGil Corporation D GA LI EJ LI MB LI PC May 5, 2017 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 d#• EsGil Corporation In (Partners/lip wit/i government for (Building Safety DATE: May 1, 2017 JURISDICTION: CITY OF CARLSBAD PLAN CHECK NO.: CBR2017-0604 SET: II PROJECT ADDRESS: 2122 SUBINA TERR. O APPLICANT %JURIS. O PLAN REVIEWER U FILE PROJECT NAME: ADDITION, REMODEL, AND NEW PATIO COVER FOR HUYNH-LEE LI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. LI The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being, held at EsGil Corporation until corrected plans are submitted for recheck. LI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: GENE LEE OR KATHERINE HUYNH EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: GENE LEE OR KATHERINE HUYNH Telephone #: 858-774-7330 Date contacted:' It (by:y-.j,,. Email: khuvnh 98yahoo.com, gene5leevahoo.com i6mail Telephone Fax In Person LI REMARKS: By: Rich Moreno Enclosures: EsGil Corporation 0 GA 0 EJ E] MB 0 PC Apr25, 2017 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 CITY OF CARLSBAD CBR2017-0604 May 1, 2017 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font are current. PLANS Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602- 2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. All sheets of plans to once again be signed by the person responsible for their preparation on re-submittal. (California Business and Professions Code). To be reverified. 15. 15-ft beam to show that 60psf LL was included in calculations. Also show the location of point load from ridge beam above. Beam B-04 needs additional foundation. Best case scenario 12"x18" continuous foundation is not enough for 6.7 or 8.4Kips point loads. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes L3 No U The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Rich Moreno at EsGil Corporation. Thank you. EsGil Corporation In (Partners flip with government for (Building Safety DATE: APR 4v 2017 XUPULAN LICANT S. JURISDICTION: CITY OF CARLSBAD REVIEWER U FILE PLAN CHECK NO.: CBR2017-0604 SET: I PROJECT ADDRESS: 2122 SUBINA TERR. PROJECT NAME: ADDITION, REMODEL, AND NEW PATIO COVER FOR HUYNH-LEE LI The plans transmitted herewith have been corrected where necessary and substantially .comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: GENE LEE OR KATHERINE HUYNH EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: GENE LEE 91 KATHERINE HUYNH Telephone #: 858-774-7330 Date contacted: . - 4\ (b") Email: khuynh 98cyahoo.com, qene5lee(vahoo.com 0.-Mail '( Telephone)( Fax In Person LII REMARKS: By: RICH MORENO Enclosures: EsGil Corporation 0 GA 0 EJ El MB 0 PC MAR 28, 2017 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 CITY OF CARLSBAD CBR2017-0604 APR 4, 2017 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: CBR2017-0604 JURISDICTION: CITY OF CARLSBAD PROJECT ADDRESS: 2122 SUBINA TERR. FLOOR AREA: Patio Cover: 200 sq-ft STORIES: 2 Addition: 115 sq-ft Remodel: 588 sq-ft HEIGHT: 22-ft DATE PLANS RECEIVED BY JURISDICTION: Mar27, 2017 DATE INITIAL PLAN REVIEW COMPLETED: APR 4, 2017 FOREWORD (PLEASE READ): DATE PLANS RECEIVED BY ESGIL CORPORATION: MAR 28, 2017 PLAN REVIEWER: RICH MORENO This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2016 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC, 2015 UPC, 2015 UMC and 2014 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. CITY OF CARLSBAD CBR2017-0604 APR 4, 2017 . PLANS Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. All sheets of plans to once again be signed by the person responsible for their preparation on re-submittal. (California Business and Professions Code). Please show smoke and carbon monoxide alarms outside the Master bedroom. . GENERAL RESIDENTIAL REQUIREMENTS Landings at exterior doors. There shall be a landing or floor on each side of each exterior door. The width of each landing shall not be less than the door served and have a minimum or 36-inches measured in the direction of travel. Exterior landings shall be permitted to have a slope not to exceed 14-inch per foot. Landings or finished floors shall not be more than 1.5 inches lower than the top of the threshold for outward swinging exterior doors or 7.75" for doors that do not swing outwards. R311.3. Please reference section call outs on sheet A2. . ROOFS/DECKS/BALCONIES Balconies and decks shall be designed for 150% of the live load required by Table 1607.1. CBC Table 1607.1, as amended by emergency building standards. Wood balconies and decks that support moisture-permeable floors shall be provided with an impervious moisture barrier system under the moisture- CITY OF CARLSBAD CBR2017-0604 APR 4, 2017 permeable floor, with positive drainage. CBC Section 2304.12.2.5, as amended by emergency building standards. 8. Specify on the plans the following information for the deck/balcony surfacing materials, per Section R106.1.1: Manufacturer's name and product name/number. ICC approval number, or equal. 9. Specify on the plans the following information for the skylights, per Section R106.1.1: Manufacturer's name and product name/number. ICC approval number, or equal. . STRUCTURAL & FOUNDATION 10. Please clarify how dead loads were developed for structural calculations. 11. Show on plans that wood shall be 6" minimum above finish grade. Section R404.1.6. 12. Provide structural calculations for 4x12 supporting ridge beam point load. Also, please note post size supporting ridge beam at Ri. a) Could not see any framing supporting 2-2.55K from mid-span ridge beam at first floor framing. 13. Please verify that two wall portions being removed from Nook area are not load bearing/Shear walls. Structural engineer to provide lateral analysis to verify sufficient lateral bracing mid-residence. 14. Please identify all beams on framing plans. 15. 15-ft beam to show that 60psf LL was included in calculations. Also show the location of point load from ridge beam above. 16. Provide structural calculations for 4x4 at kitchen to support new and existing loads. 17. Note proposed floor joist for Bedroom #2 on framing plans. 18. The plans shall indicate that special inspection will be provided for the following work. (CBC Chapter 17 and Section 107.2) a) Expansion/Epoxy anchors. Periodic special inspection should be provided for anchors installed in hardened concrete. Section 1705.3. 9 ELECTRICAL CITY OF CARLSBAD CBR2017-0604 APR 4, 2017 19. Show on the plans a wall receptacle within 36" of each lavatory in the bathroom. CEC 210.52(D). See master bathroom. 20. Include on the plans the following specifications for electrical devices installed in dwellings: CEC Article 210 & 406 Weather resistant type for receptacles installed in damp or wet locations (outside). Arc-fault protection for all outlets (not just receptacles) located in rooms described in NEC 210.12(A): Kitchens, laundry areas, family, living, bedrooms, dining, halls, etc. . RESIDENTIAL GREEN BUILDING STANDARDS The California Building Standards Commission has adopted the Green Building Standards Code and must be enforced by the local building official. The following mandatory requirements for residential construction must be included on your plans. CGC Section 101.3. The Standards apply to newly constructed residential buildings, along with additions/alterations that increase the building's conditioned area, volume or size. CGC Section 301.1.1. Provide a sheet on the plans labeled "Green Building Code Requirements" and include the following notes as applicable. 21. Indoor water use. Show compliance with the following table, per CGC Section 4.303.1. FIXTURE FLOW RATES FIXTURE TYPE MAXIMUM FLOW RATE Water closets 1.28 gallons/flush Showerheads 2 gpm @ 80 psi Lavatory faucets 1.2 gpm @ 60 psi' 1 Lavatory faucets shall not have a flow rate less than 0.8 gpm at 20 psi. Recycling. Note on the plans that a minimum of 65% of construction waste is to be recycled. CGC Section 4.408.1. Recycling. Note on the plans that the contractor shall submit a Construction Waste Management Plan, per CGC Section 4.408.2. Pollutant control. Note on the plans that during construction, ends of duct openings are to be sealed, and mechanical equipment is to be covered. CGC Section 4.504.1. Pollutant control. Note on the plans that VOC's must comply with the limitations listed in Section 4.504.3 and Tables 4.504.1, 4.504.2, 4.504.3 and 4.504.5 for: Adhesives, Paints and Coatings, Carpet and Composition Wood Products. CGC Section 4.504.2. CITY OF CARLSBAD CBR2017-0604 APR 4, 2017 Interior moisture control. Note on the plans that concrete slabs will be provided with a capillary break. CGC Section 4.505.2.1. Interior moisture control. Note on the plans that the moisture content of wood shall not exceed 19% before it is enclosed in construction. The moisture content needs to be certified by one of 3 methods specified. Building materials with visible signs of water damage should not be used in construction. The moisture content must be determined by the contractor by one of the methods listed in CGC Section 4.505.3. Indoor air quality. Note on the plans that bathroom fans shall be Energy Star rated, vented directly to the outside and controlled by a humidistat. CGC 4.506.1. Note on the plans that prior to final inspection the licensed contractor, architect or engineer in responsible charge of the overall construction must provide to the building department official written verification that all applicable provisions from the Green Building Standards Code have been implemented as part of the construction. CGC 102.3. . ENERGY CONSERVATION Residential Enemy Lighting Requirements: ES 150.0(k) All installed luminaires shall be high-efficacy in accordance with ES TABLE 150.0-A. Light sources that are not marked "JA8-2016-E" shall not be installed in enclosed luminaires. ES 150.0(k) In bathrooms, garages, laundry rooms, and utility rooms at least one luminaire shall be controlled by a vacancy sensor. Dimmers or vacancy sensors shall control all LED style luminaires. Two exceptions: Fixtures installed in hallways or (closets under 70 square feet). Recessed can light fixtures shall be IC listed, air-tight labeled, and not be equipped with a standard medium base screw shell lamp holder. ES 150.0(k) Residential ventilation requirements: ES 150.0(o)/ASHRAE 62.2 Kitchens require exhaust fans with a minimum 100 cfm ducted to the exterior. Detail compliance by including a complying exhaust fan or a ducted range hood to the exterior. Bathrooms require exhaust fans (minimum 50 cfm) to be ducted to the exterior. A bathroom is defined "as a room with a bathtub, shower, or spa or some similar source of moisture" CITY OF CARLSBAD CBR2017-0604 APR 4, 2017 Residential bathroom exhaust fans shall be energy star rated and shall be control by a humidistat capable of an adjustment between 50 and 80% humidity. CalGreen 4.506.1. Exception: Control by a humidistat is not required if the bathroom exhaust fan is also the dwelling whole house ventilation. a) All fans installed to meet all of the preceding ventilation requirements must be specified at a noise rating of a maximum I "Sone" (continuous use) or 3 "Sone" (intermittent). Alternations When replacing or modifying the mechanical system: If more than 40' of new ductwork is installed in unconditioned space, HERS inspection is required for both existing and new duct sealing. Replacement of mechanical equipment (air handler, condensing unit of an air conditioner or heat pump, cooling or heating coil, or the furnace heat exchanger) requires HERS inspection. Note: The CFI R-ALT-HVAC form may be submitted at the final inspection, it is not required at initial plan submittal. . MISCELLANEOUS If special inspection is required, the designer shall complete the city's "Special Inspection Agreement" attached at end of this list. For plans requiring waste management, designer to complete city's waste management form attached at end of list. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes L3 No 42. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any CITY OF CARLSBAD CBR2017-0604 APR 4, 2017 questions regarding these plan review items, please contact RICH MORENO at EsGil Corporation. Thank you. CITY OF CARLSBAD CBR2017-0604 APR 49 2017 (DO NOT PAY— THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: CITY OF CARLSBAD PLAN CHECK NO.: CBR2017-0604 PREPARED BY: RICH MORENO DATE: APR 41, 2017 BUILDING ADDRESS: 2122 SUBINA TERR. BUILDING OCCUPANCY: R-3/U BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Patio Cover 200 city est 81,655 Addition 115 Remodel 1319 Air Conditioning Fire Sprinklers TOTAL VALUE 81,655 Jurisdiction Code Icb IBY Ordinance I Bldg. Permit Fee by Ordinance V Plan Check Fee by Ordinance —F v] Type of Review: El Complete Review Structural Only El Repetitive Fee Other I Repeats Hourly EsGil Fee Hr. © * I $304.00 I Comments: In addition to the above fee, an additional fee 3i due (1/2hour $83/hr)for the CalGreen review. Sheet I of I macvalue.doc +