Loading...
HomeMy WebLinkAbout2550 EL CAMINO REAL; ; CBC2020-0361; PermitArAft c?, City of Carlsbad Building Permit Finaled Commercial Permit Print Date: 01/08/2021 Job Address: 2550 EL CAMINO REAL, CARLSBAD, CA 92008-1201 Permit Type: BLDG-Commercial Work Class: Tenant Improvement Permit No: CBC2020-0361 Status: Closed - Finaled Parcel #: 1670305000 Valuation: $45,000.00 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Applied: 09/22/2020 Issued: 10/13/2020 Finaled Close Out: Inspector: CRenf Final Inspection: 01/08/2021 Project Title: Description: BANK OF AMERICA: EXTERIOR LIGHTING IMPROVEMENTS Applicant: Property Owner: Contractor: ORANGE ELECTRICAL CONTRACTORS INC CARLSBAD PLAZA LIMITED ORANGE ELECTRICAL CONTRACTORS INC 448 $ MONTGOMERY WAY GEOFF REESLUND 4485 MONTGOMERY WAY ORANGE, CA 92868-4015 P0 BOX 8700 ORANGE, CA 92868-4015 (714) 771-2814 NEWPORT BEACH, CA 92658 (714) 771-2814 (949) 759-9531 x24 FEE AMOUNT BUILDING PERMIT FEE ($2000+) $374.00 BUILDING PLAN CHECK FEE (BLDG) $261.80 ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL $43.00 5B1473 GREEN BUILDING STATE STANDARDS FEE . $2.00 STRONG MOTION-COMMERCIAL $12.60 Total Fees: $693.40 Total Payments To Date: $693.40 Balance Due: $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-2700 1 760-602-8560 f I www.carlsbadca.gov (Cityof Carlsbad Job Address COMMERCIAL BUILDING PERMIT APPLICATION B-2 Plan Check iT4C2 03C / Est. Value PC Deposit Date ite: APN: 1(01 0301SjXDO Tenant Name: Ok CT/Project#: Occupancy:__________ Construction Type: Fire Sprinklers: C YES C NO BRIEF DESCRIPTION OF WORK: 04126M (h' . 1.o5I tt du- I Lot #: Air Conditioning: 0 YES 0 NO - hs Addition/New: New SF and Use, __New SF and Use, Deck SF, Patio Cover SF (not including flatwork) Tenant Improvement: SF, Existing Use Proposed Use SF, Existing Use Proposed Use D Pool/Spa SF Additional Gas or Electrical Features? E Solar: KW, _____ Modules, Mounted, Tilt: OYON, RMA:OYON, Panel Upgrade: CYON Plumbing/Mechanical/Electrical Only: Other: APPLICANT (PRIMARY CNTAT) Name: 01M Jr()(U CAikJ Name: Address: 'f'( g_.M -c _tIbuj tJJ5 Addres City: N&--Ac State: OA- Zip: qZI0t City: Phone: 7t9 '1[1 I_ Phone: Email: L_ok__QIEc1dCII4 C.OI... Email:( DESIGN PROFESSIONAL CONTRACTOR BUSINESS Name: Name: a0pwg_QAP (AdMS_tk)L Address: Address: -4_.t-L4J L4J City: State:Zip: City: State: Cfr_Zip: 'irt&( Phone: Phone: Email: Email: _CL- Architect State License: State License: %"S Bus. License:_______________ (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he/she is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-271Fax: 760-602-8558 Email: Buildingcarlsbadca.gov B-i Page 1 of 2 Rev. 03/20 PROPERTY OWNER (OPTION A ): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury one of the following declarations: Eli have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for. performance of the work for which this permit is issued. - "workers' compensation insurance carrier and policy number are: In5urncç Company Name: ..1- £k..) Policy No.V53 Sj 1014 Expiration Date: I I ;Lk L I,ertificate of Exemption: I certify that in the performance of the work for which this permit is issued, .1 shall not employ any person in any manner so as to be come subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. - CONTRACTOR SIGNATURE: DAGENT DATE: (OPTION B ): OWNER-BUILDER DECLARATION: I hereby affirm that lam exempt from Contractor's License Law for the following reason: F11, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such pPojects with contractor(s) licensed pursuant to the Contractor's License Law). Ellam exempt under Section Business and Professions Code for this reason: I personally plan to provide the major labor and materials for construction of the proposed property improvement. OYES 0 NO I (have / have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address/ phone / contractors' license number): I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work): OWNER SIGNATURE: 0 AGENT DATE- .___________ CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: Lender's Address: ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? I Yes / No Is the applicant or future building occupant required to obtain a permit from theair pollution control district or air quality management district? Yes / No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Yes/No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH.MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations over 5'O' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 360 days from the da e °1 such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commencedfor a period of 180 days 13). 11 APPLICANT SIGNATURE: . u-'' DATE: _____________ 1635 Faraday Ave Carlsbad, CA 92008 1 Ph: 760-602-2719 Fax: 760-602-8558 Email: BuiIding@JCarIsbadca.gov B-I Page 2 of 2 Rev. 03/20 Building Permit Inspection History Finaled (Ci ty o f Carlsbad Permit Type: BLDG-Commercial Application Date: 09122/ZUIU Owner: UAKILOotALi rLMf_M Lilvil u Work Class: Tenant Improvement Issue Date: 10/13/2020 Subdivision: Status: Closed - Finaled Expiration Date: 07/07/2021 Address: 2550 EL CAMINO REAL CARLSBAD, CA 92008-1201 IVR Number: 28835 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 1111812020 11I1812020 BLDG-81 Underground 143974-2020 Passed Chris Renfro Complete Combo(11,12,21,31) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-11 Foundation-Fig-Piers Yes (Rebar) BLDG-12 Steel-Bond Beam Yes BLDG-21 No Underground-Underfloor Plumbing BLDG-31 Yes Underground-Conduit Wiring 0110812021 01/0812021 BLDG-34 Rough 147780-2021 Passed Chris Renfro Complete Electrical Checklist Item COMMENTS Passed BLDG-Building Deficiency FaceTime inspection completed on Yes 1/8/2021 BLDG-Final Inspection 147781-2021 Passed Chris Renfro Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Plumbing Final No BLDG-Mechanical Final No BLDG-Structural Final Yes BLDG-Electrical Final Yes Friday, January 8, 2021 Page 1 of I EsGil A SAFEbui1t'Company DATE: 10-1-20 JURISDICTION: Carlsbad O APPLICANT 0 JURIS. PLAN CHECK #.: CBC2020-0361 PROJECT ADDRESS: 2550 El Camino Real SET: I PROJECT NAME: Bank of America LED Lighting Retrofit/Replacement The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. El The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. fl The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. LI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. LI The applicant's copy of the check list has been sent to: EsGil staff did not advise the applicant that the plan check has been completed. LI EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Mail Telephone Fax In Person LI REMARKS: By: Scott Humphrey Enclosures: EsGil 9-24-20 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 (DO NOT PAY— THIS IS NOT AN INVOICE) VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK #.: CBC2O20-0361 PREPARED BY: Scott Humnhrev DATE: 10-1-20 -- -------- BUILDING ADDRESS: 2550 El Camino Real BUILDING OCCUPANCY: -I BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code I I #N/A 11997 USC Building Permit Fee 11997 UBC Plan Check Fee _j Type of Review: E Complete Review IT Structural Only J Repebve Fee F Other FE Repeats ,- Hourly EsGil Fee r p. 1 Hrs.@* I $135.001 Comments: [In addition to the an additional fee of is due ( hour $ /hr.) for the CaiGreen reviev Sheet of E3 CPY Series TYPE BO CPY250-A-DM-F-20W-UL-WH-40K CPY250 LED Canopy/Soffit Luminaire Product Description DM Mount GC TO SEE NOTES BELOW The CPY250' LED Canopy/Soffit Luminaire has an extremely thin profile constructed of rugged cast aluminum. It can be surface mounted easily from below the canopy deck Direct imaging of the LEDs is 44 eliminated with a highly efficient patterned flat drop glass lens. Applications: Petroleum canopies, CNG fueling stations, low-medium bay general lighting, soffits Z. Performance Summary Flat Lens Made in the U.S.A. of U.S. and imported parts CR1: Minimum 70 CR1 I I CCT:Th(+/- 300KI5700K (+1- 500K) Standard 2FTJ Limited Warrantyt: 10 years on luminaire/lO years on Colorfast DeltaGuar& finish (50m11111) 1P66 Rated (Direct Mount only) Flat Glass Lens Gasket 10 Seal. 3/4' (19mm) NOT 'San ktwrbrsan.anntmunstsformaunnVtaimo up to 4.25' (108mm) Cdnduit Entry GC TO VERIFY THAT FIXTURES CAN BE MOUNTED Canopy Cutout PER PLAN AND ALL NECESSARY HARDWARE IS SPECIFIED FOR INSTALLATION PRIOR TO / • PURCHASING 150 Accessories (183mm)I ° Field-Installed I DiectMoxullLszmmnurtes canopy Upgrade Kim XA-BXCCMW - for use with Jet-Philips XA-BXCCNW - for use with Disco Franciscan XA-SXCCPW — for use with 1.51 Dakota or Masters XA-DXCCQW - for use wilh Whiteway Riviera or Rig-A-Lite XA-BXCCRW - for use with Disco Menit XA-BXCCsW— for use with ISI Richmond or Whiteway Civic Muat syrcity color Dhed Mount junction Dos/Stem 0 BXJ0OX - 60' (152mm) Hu3J4'(ltnvn) OPT Stem -Watertight - Rated for feed through 0(411,4 oaf #52 AWC candislors Deet Mount gezulqlpldar XA-BXICBPW - Plate Only XA-axccopalilw - Fists w/12'(305mm) Bsckor XA-BXCCOPBSGW - Pblsw!lr(400mm) Diekt Mounts with (4)f k— 0. Q,,If.C,llnn (279mm) Screws Weight 12.5 lbs (5.1kg) Ordering Information Example: BXCC9047& 0XCC9047& Product Vcrs.tn Mounting Optic Input Power Voltage Color Options -'- / 20W UL Wit CPYSSO A CM F Direct Flat Lens Univorsol While 120-277V c (,) us Rev. Date: Vii 2/21/2015 CREE .... US: www.cree.com/lighting T (800) 236-6800 F (262) 504-5415 Canada: www.cawe.com/canada 1 (800)473-1234 F (800) 890- 507 (3 20 I / Recommended CPY Series Lumen Maintenance Factors (LMF)' 25K Ii 50khr 75K hr if101Ch, Ambient Initial LMF Perectrd" Projected' Projected- Projected' LMF LMF LMF LMF 5C(41-F) 1.65 .04 1.09 0.93 0.93 0.92 0.87 0.81 10.0 (501:) 0.86 0.80 15C (59F) 1.02 0.97 0.91 0.84 0.79 19OT.(68F) 1.01 10.96 0.90 0.84 0.78 ;25-(17n 1.00 0.95 0.89 0.83 0.77 30C(86'F) 8.99 0.94 0.88 0.02 0.76 usmvpme vim aClTfl1mraituiatedpe?1M41 bud on U10dMn end hulltU Iundnnlretonlrngou sheet melnI 'Ifliusod,icdthlCStlA.iL51I.Il.PIC1octodYAM eprreontintepolitodeduib&oodouthOidUmIlOus that Ito %0deun (6X6uLsuto u.-80.6tauthesl for thedevlmwidnrtnudng ((JUi)I.e.thepucIcund LED cblp) nations Distribution 4000K Initial Delivered Lumens' BUG Ratings" Per TM-i 5-11 2.000 010901 lviiiuldelurend lumens aI25C(TTF) For more inlonn,Uoa ,n the 88009(8ictiabutiRlbr0Visit viwwjen.nroJP5FIErIs1aniTII-1541fln8R.IingSAddefldUm.Pdf ir4. CPY250" LED Canopy/Soffit Luminaire Product Specifications CONSTRUCTION & MATERIALS Slim, low profile design Easy mounting and servicing from below the deck Luminaire housing is constructed of rugged cast aluminum with integral heat sink specifically designed for LED Flat lens is 0.125" tempered Solite° glass Direct mount is suitable for use in single or double skin canopies with a minimum 4.0" (102mm) wide panels and a minimum 22 gauge, 0.030" (0.7mm) canopy thickness Direct mount lumina ire mounts directly to the canopy deck with the drilling of a single 2' to 4 (51 nun to 102mm) round hole, is secured in place with self-sealing screws that provides a weathertight seal and includes 3/4' (19mm) conduit entry for direct wire feed Exclusive white Colorfast DeltaGuard finish features an E-Coat epoxy primer with an ultra-durable powder topcoat, providing excellent resistance to corrosion, ultraviolet degradation and abrasion. Weight 12.5 lbs. (5.7kg) ELECTRICAL SYSTEM Input Voltage: 120-277V 50/60Hz, Class 1 drivers Power Factor: >0.9 at full load Total Harmonic Distortion: <20% at full load Integral 6kV surge suppression protection standard To address inrush current, slow blow fuse or type C/D breaker should be used l0VSource Current 0.15mA Operating Temperature Range: -40t - +45C (plywood), -40t - +50C (sheet metal! suspended) WARNING: Exceeding maximum operating temperature may result in thermal foldback REGULATORY & VOLUNTARY QUALIFICATIONS cULus Listed Suitable for wet locations when ordered with DM mount Enclosure rated 1P66 per lEC 60529 when ordered with DM mount - Consult factory for CE Certified products 6kV surge suppression protection tested in accordance with IEEE/ANSI C62.41.2 - Meets FCC Part 15 standards for conducted and radiated emissions Luminaire and finish endurance tested to withstand 5,000 hoursot.elevaledainbient salt fog conditions as defined in ASTM Standard B 117 - Meets Buy American requirements within ARRA Electrical Data* system Watts system Watts Total Current 34l-4BQVlEVl4bVJUTY OV 20 1 N/A 0.19 11 j 0.09 8.08 I N/A WA *0,ct,lcaIdatnst25CIMF) FLAT LENS RES rLTest ReportS: P10:1374001 CPy2EOA-"q-O.UL.40K lnhlalDulivea'el Lurneris4.dfi5 O(CC9047& Mounting Heightl& (4.6m) Initial Delivered Lumens: 2.000 Initial FC.st grade 52015 Cree, Inc. and/or one of Its subsidiaries. All tights reserved. For Informational purposes only. Content is subjectto change. CREE ....M - Patentwww.cree.com/patenta. Crean and Colorfast 0eltaGuard° are registered trademarks, and CPY250" andthe Cree logo are trademarks of Cree, Inc. The UL logo is a registered trademarlcofULLLC. US: wwwcree.com/Iighthg T (800) 236-6800 F (262) 504-5415 Canada: wwwcreeconeanada T (800) 473-1234 F (800) 890-7507 11.7" 1297mm1 47, (1212i rim) ZRI4C-40L40K-I0V-FD (LED 1x4) ZR-C Commercial Series TYPE EH ZR1 4TN 1, x 4' Commercial Series LEO Troffer with Matte Finish GC TO SEE NOTES BELOW Product Description The ZR-C Commercial Series is commercial spec-grade LEO troffer delivering superior energy efficiency of up to 125 lumens per watt for maximum energy savings. The ZR-C delivers a visually comforting aesthetic with better tight distribution enhanced with a soft matte finish housing. The ZR-C Commercial Series comes standard with 80+ CR1 color quality. 0-10V dimming down to 5% standard, and a new unique snap and lock room-side removable lens, making it the perfect combination of affordability and performance. Performance Summary Efficacy: Up to 125 LPW Initial Delivered Lumens: 4,000 turners Input Power: 32 watts CR1: 80+ CR1 CCT: 3000K, 3500K, 4000K. 5000K Input Voltage: 120-277 VAC Limited Warranty': 5 years on luminaire Limited Warranty Emergency Back Up (EBI Battery: 1 Year on Battery Back Up. Test regularly in accordance with local codes Controls: 0-10V dimming to 5% Mounting: Recessed Room-side accessible snap and lock removable lens See hltp:lAightieg.cree.cemlwarrarrly lurwarranly, terms Net intended far use with 9116 T.Bar grids unless used with a 9116 accessory clip like Armstmnge LFc- Fixture CUP7 which can he purchased through distribution, consult factory for non-standard grid applications. GC TO VERIFY THAT FIXTURES CAN BE MOUNTED PER PLAN AND ALL NECESSARY HARDWARE IS SPECIFIED FOR Accessories INSTALLATION PRIOR TO PURCHASING Field-Installed Drywatl Grid Adapter Wireless 0-10V Dimming/Switching Interface with Cree Smurtcasl° Technology 0GA14-WHT CIF-10V-CWC-SNSR Surface Mount Kit - For use with luminaires with 10V controls when integral SmartCasl isn't available SMK-ZR14 Cree smartcasta Technology Configuration Tool - Not for use with EB14 or CCT-CWC-1 SmartCast° Technology - One required per project when CIF-I0V is selected 6' Flexible Power Whip Chicago Plenum Field Kit PW-1816-064T-SS CPLZR For use in non-dimming - Fits all ZR types lobe installed in the field applications only GC TO VERIFY AND SPECIFY IF NOT STANDARD Ordering Information In, nd/inn rn ZR14C LOL 40K 10V FO Product Initial Delivered Lumens CCT Voltage Control CR1 Options 2R14C 40L 301< Stank by FO E814 Emergency Backup 32W. 4,000 lumens 30001< 120-277 Volt dimming to 5% 80. CR1 - 1.400 lumens 35K - Provides 90 minutes of emergency operation 35001< 401< 40001< 501< 50001< c 92, ®us .. f M41 1 10M 81 US: tighting.cree.com T (800) 236-6800 F (262) 504-5415 Rev. Date: V3 12/20/2017 Canada: www.croe.com/canada CREE T (800(473-1234 F (800) 890-7507 ZR1 4TM 1 x 4' Commercial Series LED Troffer with Matte Finish Electrical Data* Initial System Total Current IA) Delivered Watts Lumens 120-277V 120V 208V 240V 277V 40L 32 0.25 0.15 0.13 0.12 40Lw/EB14 34 0.30 0.18 0.16 - Option I 0.14 Electrical data at 25°C 17771. Actual wattage may differ by .1- 10% when operating between 120-27W+/- ZR-C Series Ambient Adjusted Lumen Maintenance' Ambient Initial LMF 25K hr Projected' LMF 50K hr Projected' LMF 75K hr Calculated' LMF lOOK hr Calculated" LMF 0'C I32°Fl 1.04 0.98 0.90 0.83 0.77 5'C 14171 1.03 0.97 0.89 0.82 0.76 10'CI5071 1.02 0.96 0.89 0.82 0.75 15'C 159F1 1.01 0.95 0.88 0.81 0.74 20°C (6871 1.01 0.95 0.88 0.81 0.74 25C I7771 1.00 0.94 0.87 0.80 0.74 30% (88°F) 0.99 0.93 0.86 0.79 0.73 35C 19571 0.99 0.93 0.86 0.79 0.73 Lumen maintenance values at 254C are calculated per tM.21 based on LM-80 data and in-vita luminaire testing. Luminaire ambient temperature factors ILATFt have been applied to all lumen maintenance factors In accordance with IESNA TM.21.11. Projected Values represent interpolated eaton based on time durations that ore within sin times 14)11 the IESNA LM-008 total test duration (in haurul for the device under touting JIDUTI La. the packaged LED chipt rio accordance with IESNA TM-21-11. Calculated Values represent time durations that exceed sin times 1601 the IESNA LM-80-0 total tout duration tin hoursi for the device under testing 1101111 i.e. the packaged LEO chipt Apptication Reference Open Space Spacing Lumens Wattage LPW wilt' Average fc 8x8 4.000 32 125 0.48 58 8x10 0.41 48 lOslO 0.32 38 10x12 0.26 30 f5• ceiling: 80/50/20 rettectancex 2.5workplane, open coon,. LU': 1.0 Initial Open Space: 50 n40 x Product Specifications CONSTRUCTION & MATERIALS Durable 22 ga.cold rolled steel housing provides strength and uniformity Ultra-thin 3.9" (99mm) luminaire height and lightweight design effectively target a broad range of plenum spaces and allow for easy installations Luminaire is pre-painted for enhanced smooth matte finish Includes I-bar clips and holes for mounting support wires (by others) Luminaire sides and ends are hemmed in for safe, easy handling Includes lens gasket to prevent ingress of insects Not for installation within 3 (76mm) of insulation Removable lens for easy maintenance and cleaning Magnetic lens to prevent dust and bug intrusion OPTICAL SYSTEM Unique luminaire design creates perfect balance of both horizontal and vertical illumination - Optimized -smooth acrylic lens eliminates pixelalion and delivers a low-glare, diffused light distribution ELECTRICAL SYSTEM Power Factor: = 0.9 nominal Input Power: Stays constant over Life Input Voltage: 120-277V, 60Hz Operating Temperature Range: 0°C - + 35°C (32°F - + 95°F) Total Harmonic Distortion: e20%; c 22% )E814) CONTROLS Continuous dimming to 5% with 0-10V DC control protocol 10V Source Current: 0,25mA For use with Class 2 dimming systems only Use only lighting controls with neutral Connection or controls intended for use with LED fixtures Reference www.creetink.com/exLink.asp?7098214OZ58R34126620963 for recommended dimming controls and wiring diagrams REGULATORY & VOLUNTARY QUALIFICATIONS cULus Listed Suitable for damp locations Designed for indoor use U1924 fEB option). Maximum mounting height: 15.0'(4.6m] RoHS compliant. Consult factory for additional details Meets FCC Part 15, Subpart B, Class A standards for conducted and radiated emissions DLC Premium qualified. Please refer to www.designlights.org/OPL for most current information -I CREE US: lighting.cree.com 1 (800) 236-6800 F (262) 504-5415 . Canada: www.cree.com/canada T (800)473-1234 F (800)890-7507 ZR14TM V x 4' Cbmmercial Series LED Troffer with Matte Finish Photometry ZR14C-40L-30K-10V-FD BASED ON CESTL REPORT TEST #: PL10453-O01A Luminaire photometry has been conducted by a NVLAP accredited testing laboratory in accordance with IESNA LM-79-08. IESNA LM-79-08 specifies the entire lumin a i r e as the source resulting in a Luminaire efficiency of 100%. Coefficients Of Utilization - Zonal Cavity Method RC %: 80 RW%: 70 ']50 - 30 10 119 1119 119 119 1 109 f 104 100 96 2 99 [91 84 78 3 90 180 71 65 4 83 [70 62 55 5 76 6 70 Al 7 65 8 ] 3522 9 57 43 10 53 Zonal Lumen Summary Zone Lumens % Lamp Luminaire 0-30 1,058 N/A 27.7% 0-40 1,725 N/A 45.2% 0-60 3,016 N/A 79.0% 0-98 3,818 N/A 100% 0-180 3.818 N/A 100% Average Luminance Table (cd/mtl Horizontal Angle 0. 45 90 !!!_. _ 810 -955 7,336 8,018 8,618 65 6417 7.661 8.329 75 51.57 7.020 6.627 85 3,535 4,433 3.365 90 70 50 Effective Floor Cavity Reflectance, 25% Relerence hltp,IILighting.crne.com!productslindoorltrolletshr.seties for detailed photometric data 182017 Cree. Inc. and/or one of its subsidiaries. All rights reserved. For informational purposes only. Content is subject to change. w Patent ww.cree.com/patenls. Cree6and SmartCast°' are registered trademarks, and the Cree logo and ZR147° are trademarks of Cree, Inc. The UL logo is registered trademark of UL I.I.C. Armstrong" is registered trademark of AWl Licensing LLC. The DLC 0131-Premium Logo is registered trademark of Northeast Energy Efficiency Partnerships. Inc. CREE 'W. US: tighting.cree.com T 18001236-6800 F 12621504-5415 Canada: www.creo.com/canada T 18001473-1234 F (8001890-7507 ZR24C-40L40K-I0V (LED 2x4) GCTO S EE- NOTES BELOW Product Description The ZR-C Commercial Series is a commercial spec-grade LED troffer delivering superior energy efficiency of up to 125 lumens per watt for maximum energy savings. The ZR-C delivers a visually comforting aesthetic with better light distribution enhanced with a soft matte finish housing. The ZR-C Commercial Series comes standard with 80+ CR1 color quality, 0- 10V dimming down to 5% standard, and a new unique snap and lock room-side removable lens, making it the perfect combination of affordability and performance. Performance Summary Efficacy: Up 10125 LPW Initial Delivered Lumens: 4,000 lumens Input Power: 32 watts 3.9" CR1: 80+ CR1 •-• (99 M) ZR-C Commercial. Series TYPE EM ZR24TM 2'x 4' Commercial Series LED Troffer with Matte Finish CCT: 3000K. 3500K, 4000K, 5000K Input Voltage: 120-277 VAC Limited Warranty*: 5 years on luminaire Limited Warranty Emergency Back Up (EBI Battery: 1 Year on Battery Back Up. Test regularly in accordance with local codes Controls: 0-10V dimming to 5% Mounting: Recessed Room-side accessible snap and lock removable lens See htlp.Jflighling.cree.com/warranty for warranty terms 'Not intended for use with 9/16T-6ar grids unless used with a 9/16 accessory clip like A1m51r0n9 LFc- Fixture Clip which can be purchased through distribution. Consult factory for ens-standard grid applications. GC TO VERIFY THAT FIXTURES CAN BE MOUNTED PER PLAN AND ALL NECESSARY HARDWARE IS SPECIFIED FOR Accessories INSTALLATION PRIOR TO PURCHASING Field-Installod Drywall Grid Adapter Wireless 0-10V Dimming/Switching Interlace with Cree Soiartcaste Technology 00A26-WHT CIF-10V-CWC-SNSR Surface Mount Kit - For use with luminaires with iSV controls when integral SmarlCast sot available SMK-ZR24 Cree SmartCaotm Technology Configuration Tool - Not for use with EB14 or CCT.CWC-1 SmurtCasl° Technology - One required per project when CIF-10V is selected 6' Flexible Power Whip Chicago Plenum Field Kit PW-1W4-06-9TS CPLZR - For use In non-dimming - Fits all ZR types to be installed in the field applications only GC TO VERIFY AND IF Ordering Information Foamole 2R24C-60L-35K-1OV-FD 11 r Tim) ZR24C 40L 40K 10V FO Product Initial Delivered Lumens CCT Voltage Control CR1 Options ZR26C 40L 30K Stank isV PD E616 EmergencyBackup 32W. 6.000 lumens 3000K 120-277 VoLt jV dimming 105% 80. CR1 - 1.400 lumens 35K - Provides 90 minutes of emergency operation 3500K 40K 4000K 50K 5000K c®uS • Rev. Date: V3 12/20/2017 CREE US: lighting.cree.com T 18001236-6800 F 12621504-5415 Canada: www.cree.com/canada T 18001473-1236 F 18001890-7507 ZR24TM 2'x4' Commercial Series LED Troffer with Matte Finish Electrical Data* Initial 1 System Total Current (Al I I I Delivered Watts Lumens 120-277V 120V 208V 240V ( 277V 40L 1 32 0.25 0.15 0.13 0.12 40LwlEB14 34 0.30 0.18 0.16 014 Option Electrical data at 25°C I77FI. Actual wattage may differ by .I- 10% when operating between 120-277V.!- 10% ZR-C Series Ambient Adjusted Lumen Maintenance' Ambient Initial LMF 25K hr Projected LMF 501(hr Projected' LMF 75K hr Calculated' LMF 100Khr Calculated' LMF 0C I32Fl 1,04 0.98 0.90 0.83 0.77 5Cl41FI 1.03 0.97 0.89 0.82 0.76 10C15071 1.02 0.96 0.89 0.82 0.75 15-C [5971 1.01 0.95 0.88 0.81 0.74 20°C I6871 1.01 0.95 0.88 0.01 0.74 25°C 177F1 1.00 0.94 0.87 0.80 0.74 30C 186°Fl 0.99 0.93 0.86 0.79 0.73 35C 195° Fl 0.99 0.93 0.86 0.79 0.72 'Lumen maintenance values at 25% are calculated per 11.1-21 based on 11.1-80 data and in silo tuminaire testing. Luminaire ambient temperature factors hAlF! Iran been applied to all lumen maintenance factors In accordance with IESNA 114-21-11, Projected Values represent interpolated value based on time durations that are within sin times 1601 the IESNA 11,4.80-00 total test duration lie hours! for the desire under testing IlDUTI i.e. the packaged LED chip! °In accordance with IESNA 11.1-21-11, Calculated Values represent time durations that exceed sin limes lox! the IESNA 014-00-0e total tent duration (in hoursi for the device under testing lOUT! i.e. the packaged LED chip] AppLication Reference Open Space Spacing Lumens Wattage LPW w/ft° Average fc 808 4,000 32 125 0.48 58 8010 0.41 47 10 10 0.32 38 lOx 12 0.26 30 tO' ceiling: 80/50120 telLectances: 2.5' workplane, open mom. LLF: 1.0 Initial. Open Space. 50' o40' o tO' Product Specifications CONSTRUCTION & MATERIALS Durable 22 ga. cold rolled steel housing provides strength and uniformity ULtra-thin 3.9" (99mm) luminaire height and lightweight design effectively target a broad range of plenum spaces and allow for easy installations Luminaire is pre-painted for enhanced smooth matte finish Includes t-bar clips and holes for mounting support wires (by others) Luminaire sides and ends are hemmed in for safe, easy handling Includes tens gasket to prevent ingress of insects Not for installation within 3" (76mm) of insulation Removable Lens for easy maintenance and cleaning Magnetic lens to prevent dust and bug intrusion OPTICAL SYSTEM Unique Luminaire design creates perfect balance of both horizontal and vertical illumination Optimized smooth acrylic lens eliminates pixelation and delivers a tow-glare, diffused light distribution ELECTRICAL SYSTEM Power Factor: = 0.9 nominal Input Power: Stays constant over life Input Voltage: 120-277V, 60Hz Operating Temperature Range: 0°C - + 35°C (32°F - + 95F) Total Harmonic Distortion: 20%; 22% (EB1/e1 CONTROLS ° Continuous dimming to 5% with 0-10V DC control protocol IOV Source Current: 0.25mA For use with Class 2 dimming systems only ° Use only lighting controls with neutral connection or controls intended for use with LED fixtures ° Reference www.creelink.com/exLink.asp770982140Z58R34I26620963 for recommended dimming controls and wiring diagrams REGULATORY & VOLUNTARY QUALIFICATIONS ° cULus Listed ° Suitable for damp locations Designed for indoor use ° UL924 (EB optionl. Maximum mounting height: 15.0' (4.6m) ° RoHS compliant. Consult factory for additional details Meets FCC Part 15, Subpart B. Class A standards for conducted and radiated emissions ° DLC Premium qualified. Please refer to www.designlights.org/QPL for most current information CREE...- US: lighting.cree.com T (8001236-6800 F 12621504-5415 Canada: www.cree.com/canada 1 (8001473-1234 F 1800) 890-7507 ZR24TM 2'x 4' Commercial Series LED Troffer with Matte Finish Photometry ZR24C-40L-30K-IOV-FD BASED ON CESTL REPORT TEST #: PL10456-001A Luminaire photometry has been conducted by a NVLAP accredited testing Laboratory in accordance with IESNA LM-79-08. IESNA LM-79-08 specifies the entire tuminaire as the source resulting in a tuminaire efficiency of 100%. Coefficients Of Utilization - Zonal Cavity Method RC %: 80 RW%: 70 50 30 10 RCR:0 119 119 119 119 1 108 103 98 94 2 98 89 82 76 3 89 78 70 63 4 81 69 60 53 5 75 62 53 46 6 69 56 46 60 7 64 50 41 35 8 60 46 1 37 1 31 9 56 42 34 28 10 52 39 31 26 Effective Floor Cavity Reflectance, 20% 2onaL Lumen Summary Zone Lumens %Lamp Luminaire 0-30 1,028 N/A 26.6% 0-40 1.676 N/A 43.6% 0-60 2.940 N/A 76.1% 0-90 3,864 N/A 100% 0-180 3,864 N/A 100% Average Luminance Table lcd/mtl Horizontal Angle 0' 45 90' 45' 7.658 8,232 8.658 55' 7,051 7,940 8.712 65' 6,324 7,911 9.175 75 5,218 8.331 10,039 3,574 1 9,654 9,878 90' 70 50' Reference http:/Itighting.cree.cem!pradactnjindoar/traffers/zr-series to, detailed photometric data © 2017 Cree, Inc. and/or one of its subsidiaries. All rights reserved. For informational purposes only. Content is subject to change. Patentwww.cree.com/patents. Cree5and SmartCasteare registered trademarks, and the Cree toga and ZR2&mare trademarks of Cree, CREE Inc. The ULlogo is registered trademark of UL I.I.C. Armstrong5 is a registered trademark of AWl Licensing I.I.C. The DLC OPL Premium logo is registered trademark of Northeast Energy Efficiency Partnerships, Inc. 'W. US: Lighttng.croe.com T 18001236-6800 F (2621504-5415 Canada: www.creo.com/canada T 18001473-1234 F 18001890-7507 18.3" (464mm) + _-j ri (1m) "A" LED Count lxi Of Dim. "A" ' Weight 02 99" I251mmI 20 tbs. I9.1kgl 04 119" 1303mm1 22 tbs. I10.okgl 06 13.9 I353mml 25 tbs. I11.3kg1 08 159" 1404mm1 27 tbs. (12.2kg! 10 17.9' I455mml 31 tbs. 114.1 kgl 12 199" (505mm1 32 tbs. (14.5kg) SEC-EDG-2S—WM-02—E—UL—XX-350-40K Cree Edge1M Series TYPE SA LED Security WaLL Pack Luminaire Product Description CONTRACTOR TO SEE NOTES BELOW The Cree EdgeTH watt mount luminaire has a slim, low profile design. The luminaire end caps are made from rugged die cast aluminum with integral, weathertight LEO driver compartments and high performance aluminum heat sinks specifically designed for LEO applications. Housing is rugged aluminum. Includes a lightweight mounting box for installation over standard and mud ring single gang i-Boxes. Secures to wall with four 3/16' (5mm) screws (by others). Conduit entry from top, bottom, sides and rear. Allows mounting for uptight or downhight. Designed and approved for easy through-wiring. Includes leaf/debris guard. Applications: General area and security lighting Performance Summary Patented Nano0ptic5 Product Technology Made in the U.S.A. of U.S. and imported parts CR1: Minimum 70 CR1 CCI: 4000K l+/- 300K), 57001< 1+1- 5001<) standard Limited Warranty': 10 years on luminaire/10 years on Colorfast DeltaGuardo finish 'See httplflighting.c ee.cemlwurranty for warranty terms CONTRACTOR TO VERIFY THAT FIXTURES CAN BE MOUNTED PER PLAN AND ALL NECESSARY HARDWARE IS SPECIFIED FOR INSTALLATION. PRIOR Accessories TO PURCHASING Field-Installed Bird Spikes Hand-Held Remote XA-SRDSPK XA-SENSREM - For successful implementation of the programmable multi-tenet oplion, a minimum of one hand-held remote is required CONTRACTOR TO VERIFY AND SPECIFY IF NOT UL Ordering Information - CONTRACTOR TO REFERENCE PLANS FOR COLOR DESIGNATION SEC-EDO 2S WM 02 1 E UL 1 XX 350 40K Product Optic Mounting LED Count Series Voltage Color Drive Current OptionsOptions lxlol SEC-EDO ZM WM 02 E UL BK 350 DIM 0-10VDimming Type II Medium Wall Mount 04 Universal 120-277V Black 350mA 525 - Control by others - Refer to Dimming spec sheet for details 2MB Type II Mediemw/BLS 06 08 uH BZ Bronze 525mA - Can't exceed specified drive current 25 10 Universal sv -Available with 20-80 LEOs F Fuse Type II Short 347-480V Silver 700 - Refer to ML spec sheet for availability with ML options 12 34 WH 700mA - Available with UL voltage only 25B Type II Short wJBLS 367V White -'Available with 20-60 LEDs - When code dictates fusing, use time delay fuse 3M ML Multi-Level - Refer to ML spec sheet for details Type Ill Medium - Intended for downlight applications of e tilt 3MB . P photocell Type Ill Medium w/BLS - Refer to ML spec sheet for availability with ML options - Must specify UL or 34 voltage Type IV Medium PML Programmable Multi-Level 4MB - Refer to PML spec sheet for details Type IV Medium w/OLS . - Intended for downlighl applications of Ot tilt 40K 4000K Color Temperature - Minimum 70 CR1 - Color temperature per luminaire c®us LIM l . Rev, Date: V2 07/20/2016 CREE US: lighting.croe.com/lightiflg T 18001236-6800 F (2621504-5415 Canada: www.cree.com/canada 1 18001473-1234 F (800) 890-7507 Cree EdgeTM LED Security Wall Pack Luminaire Electrical Data* LED Count (xl0) System Watts 120-480V Total Current 120V 208V 240V 277V 347V 480V 350mA 02 25 0.21 0.13 0.11 [0.10 0.08 0.07 04 46 0.36 0.23 0.21 [ 0.20 0.15 0.12 06 66 0.52 0.31 0.28 0.26 0.20 0.15 08 90 0.75 0.44 0.38 0.34 0.26 0.20 10 110 0.92 0.53 0.47 0.41 0.32 0.24 12 130 1.10 0.63 0.55 0.48 0.38 0.28 525mA 02 37 0.30 0.19 0.17 0.16 0.12 0.10 04 70 0.58 0.34 0.31 0.28 0.21 0.16 06 101 0.84 0.49 0.43 0.38 0.30 0.22 08 133 1.13 0.66 0.58 0.51 0.39 0.28 700mA 02 50 0.41 0.25 0.20 0.15 0.12 01. 93 0.78 0,46 0.40 0.36 0.27 0.20 06 134 1.14 0.65 0.57 0.50 0.39 0.29 Electrical data at 25C I7771 Recommended Cree EdgeTM Series Lumen Maintenance Factors (LMFI' Ambient Initial LMF 25K hr Projected' LMF 50K hr Projected' LMF 75K hr Calculated' LMF 100l(hr Calculated' LMF 5C 141Fl 1.04 0.99 0.97 0.95 0.93 10C I50'FI 1.03 0.98 0.96 0.94 0.92 15C 15971 1.02 0.97 . 0.95 0.93 0.91 20% f6871 1.01 0.96 0.94 0.92 0.90 25'C (77F1 1.00 0.95 0.93 0.91 0.89 Lumen maintenance values at 25'C are calculated per T14-21 based on LM-80 data and in-situ laminaire tenting In accordance with IESNATM.21-1I, Prajected Values represent Interpolated value based on time durations that are within sin times IÔXI the IESNA LM-50-08 total lest duration tin hoursi for the device under testing (IDUTI I.e. the packaged LED thipt 'In accarduncewith IESNATP4-21-I I, Calculated Values represent time durations that exceed sin limes 16Xl the 1E5NA LM-80.08 taut test duration tin hours) for the device under testing IIOUTI i.e. the packaged LEO chipi Product Specifications CONSTRUCTION & MATERIALS Slim, low profile design Luminaire sides are rugged die cast aluminum with integral. weathertight LED driver compartment and high performance aluminum heat sinks specifically designed for LED applications Housing is rugged aluminum Furnished with tow copper, light weight mounting box designed for installation over standard and mud ring single gang J-Boxes Luminaire can also be direct mounted to a wall and surface wired Secures to wall with four 3/16" 15mm) screws (by others) Conduit entry from top, bottom, sides, and rear Allows mounting for uptight or downlight Designed and approved for easy through-wiring Includes leaf/debris guard Exclusive Colorfast DeltaGuard° finish features an E-Coat epoxy primer with an ultradurable powder topcoat, providing excellent resistance to corrosion, ultraviolet degradation and abrasion. Black, bronze, silver and white are available Weight: See Dimensions and Weight Chart on page 1 ELECTRICAL SYSTEM Input Voltage: 120-277V or 347-480V, 50/60Hz, Class 1 drivers Power Factor: s 0.9 at full load Total Harmonic Distortion: c 20% at full load Integral weathertight J-Box with leads (wire nuts) for easy power hook up Integral 10kV surge suppression protection standard To address inrush current, slow blow fuse or type C/D breaker should be used Maximum 1OV Source Current: 20 LED )350mA): lOmA; 20LED (525 & 700 mA) and 60-120 LED: 0.15mA REGULATORY & VOLUNTARY QUALIFICATIONS cULus Listed Suitable for wet Locations a Meets FCC Part 15 standards for conducted and radiated emissions Enclosure rated IP66 per IEC 60529 when ordered without R PML or ML options 10kV surge suppression protection tested in accordance with IEEE/ANSI C62.41.2 Luminaire and finish endurance tested to withstand 5,000 hours of elevated ambient salt fog conditions as defined in ASTM Standard B 117 DLC qualified. Exceptions apply when ordered with full backlight control. Please refer to www.designlights.org/QPL for most current information Dark Sky Friendly, IDA Approved. Please refer to www.darksky.org/ for most current information Meets Buy American requirements within ARRA CREE US: tighting.cree.cons/tighting T (800) 236-6800 F (262) 504-5415 Canada: we.cree.com/canada T (800)473-1234 F (800) 890-7507 2S ITL Test Report 0:79175 SEC-EDG-2S-"-06-E-UL-700-401( Initial Delivered Lumens: 11,704 SEC-EDG-2S-"-08-E-UL-525-40K. Mounting Height: 10' I3.oml A.F.G. Initial Delivered Lumens: 12,604 Initial FC at grade CSA Tent Report 0:6454 ARE-EDD-258-"-06-E-UL-700-4014 Initial Delivered Lumens: 9,202 c. S ,ad44.tf. SEC-EOG-2SB-'-08-E-UL-525-401( Mounting Height: 1013.0m) A.F.G. Initial Delivered Lumens: 9,683 Initial FC at grade 2SB Cree EdgeiM LED Security Wall Pack Luminaire Photometry All published Luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project consult: hltp://tighting.cree.Com/produCts/outdOOr/WattmoUfll/creeedgeserieS5 US: lighting.cree.corn/tighting '110001 236-6800 F (2621504-5415 Type II Short Distribution LED Count IxiOl 40001< 57001< Initial ' Delivered Lumens' BUG Ratings" PerTM-15-11 Initial Delivered Lumens BUG Ratings" PerTM-15-11 350mA 02 2.277 B1 USD1 2,366 BI U061 06 6.553 81 UO 131 4.728 81 UO 01 06 6.752 82 US G2 7,012 B2 UO G2 08 - 9,003 82 US 02 9,369 B2 UO G2 10 11.226 83U063 11.658 B3U003 12 13.472 B3USG3 13,990 B3U003 525mA 02 3,187 81 UO 61 3.310 81 UO 01 04 6.375 B2 US 02 6.620 82 UO G2 06 9,653 82U002 9.816 B3UOG3 Be 12,604 83U063 13.088 B3UOD3 700mA 02 3,893 81 UO 61 4,043 81 UO GI 06 7.786 82 US 02 8,086 82 US 02 06 11,566 B3USD3 11.990 03U063 Inilint dntivnred lumens at 25i Ill-SI For more inlarmation an the IES BUG IBackLight-Uptighl'alarel Rating visit: wvel.ies.ors1Pop1ErrntustTM-15-llaaggatingsAddendam.pdl Type II Short Distribution w/BLS LEO Count (xlo) 40001< 57001< Initial Delivered Lumens' BUG Ratings' Per TM-i 5-11 Initial Delivered Lumens' BUG Ratings" Per TM-15-11 350mA 02 1,749 • BOUOG1 1,816 BOUOD1 04 3,498 81 UO G1 3,633 81 US D1 06 5,188 01 UO G1 5,387 81 UO G1 08 6,917 81 UO GI 7,183 , 01 UO Dl 10 8.625 B2UOD1 8,957 82U001 12 10,350 B2 UO 62 10,748 82 UO 62 525mA 02 2,449 51 USD1 2,543 B1 UOG1 04 4.898 81 US D1 5,086 81 UO GI 06 7,263 B1 USD1 7,542 51 UO GI 08 9,483 B2 UO 62 10,056 82 UO 62 700mA 02 2,991 81 UOG1 3,106 BI UO GI 06 5,982 81 UO GI 6,212 81 US D1 06 8.871 B2 UO G1 9,212 02 UO 62 'Initial delivered lemons at bc 11151 "For more information an the IES BUS lBacldighl-Uplight'GLarel Rating visit: m4v5.ies.orgIPDF/trralas/TM-15-118ugRalisgsAddeod wn.pdl Al l, Canada: www.cree.com/canada T 18001473-1234 F 18001890-7507 18.3" (464mm) 4.1 (1,m) - Lb-I "A" LED Count (00) Dim. "A" Weight 02 99" (251 mm) 20 tbs. (9.1kg) 04 11.9' (303mm) 22 tbs. (10.0kg) 06 13.9" (353mm) 25 tbs. (11.3kg) 08 15.9' (404mm) 27 tbs. (12.2kg) 10 17.9(455mm) 31 tbs. (14.1kg) 12 19.9" (505mm) 32 tbs. (14.5kg) SEC-EDG-2S-WM-02-E-UL-XX-525-40K Cree EdgeTM Series TYPE SB LED Security WaLL Pack Luminaire Product Description CONTRACTOR TO SEE NOTES BELOW The Cree Edgem wall mount Luminaire has a slim, Low profile design. The luminaire end caps are made from rugged die cast aluminum with integral, weathertight LED driver compartments and high performance aluminum heat sinks specifically designed for LED applications. Housing is rugged aluminum. Includes a lightweight mounting box for installation over standard and mud ring single gang J-Boxes. Secures to wall with four 3116" 15mm) screws (by others). Conduit entry from top, bottom, sides and rear. Allows mounting for uptight or downlight. Designed and approved for easy through-wiring. Includes leaf/debris guard. Applications: General area and security lighting Performance Summary Patented NanoOptice Product Technology Made in the U.S.A. of U.S. and imported parts CR1: Minimum 70 CR1 CCT: 4000K (+1- 300K), 5700K (+1- 500K) standard Limited Warranty': 10 years on luminaire/lO years on Colorfast DeltaGuard° finish 'See htlp'J/llghting.cre.comlwan'antylerwarrostyturms CONTRACTOR TO VERIFY THAT FIXTURES CAN BE MOUNTED PER PLAN AND ALL NECESSARY HARDWARE IS SPECIFIED FOR INSTALLATION PRIOR Accessories TO PURCHASING Field-Installed Bird Spikes Hand-Held Remote XA-BRDSPK XA-SENSREM - For successful implementation of the programmable multi-level option, a minimum of one hand-held remote is required CONTRACTOR TO CONTRACTOR TO VERIFY REFERENCE PLANS AND SPECIFY IF NOT UL FOR COLOR DESIGNATION Ordering Information [4:' rfln..rJ..WMnArtll ..cv,.'onn WIN! - 02 - E UL XX 525 40K 7SEC--EDC2 Mounting LED Count Series Voltage Color OptioIIS Drive current Options WM 02 E UL BK 350 DIM 0-IOVDimming edium Walt Mount 04 Universal Black 350mA - Control by others 2MB 06 120-277V BZ 525 - Refer to Dimming spec sheet for details Typo II Medium w/BLS 08 UH Bronze 525mA - Can't exceed specified drive current 10 Universal sv -Available with 20-80LEDs F Fuse Type II Short Sifeer 700 - Refer to ML spec sheet for availability with ML options 2SB 12 . 34 WH 700mA - Available with UL voltage only Type II Short w/BLS 347V White Available with 20-60 LEDs - When code dictates fusing, use time delay fuse 3M ML Multi-Level Type III Medium - Refer to ML spec sheet for details 3MB - Intended for downlight applications of 0 tilt Type III Medium w/BLS P Photocell - Refer to ML spec sheet for availability with ML options Type IV Medium - Must specify UL or 34 voltage 4MB PML Programmable Multi-Level Type IV Medium w/BLS - Refer to PML spec sheet for details - Intended for downlight applications of 00 tilt 40K 4000K Color Temperature - Minimum 70 CR1 - Color temperature per tuminaire us LIM '01% C@ J1030111 111~01 US: Ughting.cree.com/(ighting T 1800)236-6800 F (262) 504-5415 Rev. Date: V2 07/28/2016 Canada: www.creo.comlcanada CREE T (800) 473-1234 F (800) 890-7507 Cree Edge1M LED Security Wall. Pack Luminaire Electrical Data' LED Count lxi 01 System watts 120-400'! Total Current - 120'! 208'! 240'! 277'! 347'! 480'! 350mA 02 25 0.21 0.13 0ii 0.10 0.08 0.07 04 46 0.36 0.23 0.21 0.20 0.15 0.12 06 66 , 0.52 0.31 0.28 0.26 0.20 0.15 08 90 0.75 044 0.38 0.34 0.26 0.20 10 110 0.92 0.53 8.47 0.41 0.32 0.24 12 130 1.10 0.63 0.55 0.48 0.38 0.28 525mA 02 37 • 0.30 0.19 0.17 0.16 0.12 0.10 04 70 0.58 - 0.34 0.31 0.28 0.21 016 06 101 0.04 0.49 0.43 0.38 0.30 0.22 08 133 1.13 0.66 0.58 0.51 0.39 0.28 700mA 02 [50 0.41 0.25 0.22 0.20 0.15 0.12 04 ]93 0.78 0.46 0.40 0.36 0.27 0.20 06 M 1.14 0.65 0.57 0.50 0.39 0.29 Electrical data at 25C Ifl'FI Recommended Cree Edge's Series Lumen Maintenance Factors ILMFI' Ambient Initial LMF 25K hr Projected2 LMF 50K hr Pmjected2 LMF 75K hr Calculated3 LMF 1001(hr Calculated LMF S.0 I41'Fl 1.04 0.99 0.97 0.95 0.93 1DC15071 1.03 0.98 0.96 0.94 0.92 15'C15971 1.02 0.97 0.95 0.93 0.91 20'C (68F1 1.01 0.96 0.94 0.92 0.90 25C (77F1 1.00 0.95 0.93 0.91 0.89 Lames maintenance values at 25'C are calculated perlM-21 based on UI-SO data and In-situ iumlnaire testing In accordance with iE5NATt4-21-11, Projected \tetuts represent interpolated value based on time durations that are within six limes (61(1 the IEsNAU.l-at-08 total test duration tin hours) for the device under testing ((DLIII i.e. the packaged LED chip) In accordance wIth iESNATM-21-1 I, Calculated Values represent time durations that exceed sin times (61(1 the IESNA Lid-SO-Os total test duration (in hours) for the device under testing ((OUT) tn the packaged LED chip) Product Specifications CONSTRUCTION & MATERIALS Slim, low profile design Luminaire sides are rugged die cast aluminum with integral, weathertight LED driver compartment and high performance aluminum heat sinks specifically designed for LED applications Housing is rugged aluminum Furnished with low copper, light weight mounting box designed for installation over standard and mud ring single gang i-Boxes Luminaire can also be direct mounted to a wall and surface wired ° Secures to wall with four 3/16' (5mm) screws (by others) Conduit entry from top, bottom, sides, and rear Allows mounting for uptight or downlight Designed and approved for easy through-wiring Includes leaf/debris guard Exclusive Colorfast DeltaGuard° finish features an E-Coat epoxy primer with an ultradurable powder topcoat, providing excellent resistance to corrosion, ultraviolet degradation and abrasion. Black, bronze, silver and white are available Weight: See Dimensions and Weight Chart on page 1 ELECTRICAL SYSTEM Input Voltage: 120-277V or 347-480 V. 50/60Hz, Class 1 drivers Power Factor. s 0.9 at full load Total Harmonic Distortion: < 20% at full load Integral weathertight i-Box with leads (wire nuts) for easy power hook up Integral 10kV surge suppression protection standard To address inrush current, slow blow fuse or type C/U breaker should be used Maximum 'lIlY Source Current: 20 LED (350mA): lOmA; 20LED (525 & 700 mA) and 40-120 LED: 0.15mA REGULATORY & VOLUNTARY QUALIFICATIONS cULus Listed Suitable for wet locations Meets FCC Part 15 standards for conducted and radiated emissions Enclosure rated IP66 per IEC 60529 when ordered without P, PML or ML options 10kV surge suppression protection tested in accordance with IEEE/ANSI C62.41.2 Luminaire and finish endurance tested to withstand 5,000 hours of elevated ambient salt fog conditions as defined in ASTM Standard B 117 DLC qualified. Exceptions apply when ordered with full backlight control. Please refer to www.designlights.org/QPL for most current information Dark Sky Friendly, IDA Approved. Please refer to www.darksky.org/ for most current information Meets Buy American requirements within ARRA CREE US: lighting.cree.Com/tlghting T1800)236-6800 1'(2621504-54115 Canada: www.cree.com/cansda T (800) 473-1234 F 1800) 890-7507 258 CSA Test Report 8:6654 SEC-EDO-2sB--08-E-UL-525-40K ARE-006-2S81-06-E-UL-700-40K Mounting Height: 10' I3.0ml A.F.G. Initial Delivered Lumens: 9,202 Initial Delivered Lumens: 9,683 Initial FC 01 grade Cree EdgeTM LED Security WaLL Pack Luminaire Photometry ALL published Luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited Laboratory. To obtain an IES file specific to your project consult: http:/Ilighting.cree.com/products/outdoor/waU-mount/cree-edge-series-5 25 US: lighting.cree.com/Lighting T (800)236-6800 F[2621504-5415 Type II Short Distribution LED Count lxi 01 [000K 5700K Initial Delivered Lumens' BUG Ratings" Per TM-i 5-li Initial Delivered Lumens' BUG Ratings Per TM-i 5-li 350mA 02 2,277 Bi UO GI 2.364 01 UQ0i 04 4,553 Bi uo 01 4,728 81 UO 01 06 6.752 B2UOG2 7,012 82U002 08 9,003 82 uo 02 9,349 B2 UO 62 10 11,226 B3UDG3 11,658 B3UD03 12 13.472 B3U003 13,990 83 UO 03 525mA 02 3,187 81 UO 01 3,310 81 UO 01 04 6,375 82 UO 02 6.620 02 UO 02 06 9,453 B2 uo 02 - 9,816 B3 UO 83 08 12.604 B3U003 13.088 jB3UQG3 700mA 02 3,893 at UI! 61 4,043 B1 UI! 01 04 7,786 02 UO G2 8,086 B2 UI! 02 06 11,546 83U003 11.990 83U003 Initial delivered! menu at 25'C I7TFI "For mare information on the 18$ 8U6 IBadctighl-uplight-tlarol Rating visit: wrew.hs.orglPDFilirretas(TM-15-ll Bug Rath,gsAddendam.pdl Type II Short Distribution wfBLS LED Count IxID) 6000K j 5700K Initial Delivered I Lumens' 1BUG I Ratings" I PerTM-15-11 Initial Delivered Lumens' BUG Ratings PerTM-15-11 350mA 02 1.749 BOUOG1 1,816 00U001 04 3,698 81 U001 3,633 at UOG1 06 5,188 BlUODl 5.387 B1U0G1 08 6.917 BI UO G1 7,183 MUM 10 8,625 82 UI! 01 8,957 B2 UI! 01 12 10,350 B2UD02 10.748 B2UOG2 525mA 02 2,449 Bi UOG1 2,543 at U061 04 4.898 BI UI! 01 5,086 BI UO 01 06 7,263 81 UO 01 7,542 81 U0G1 08 9,683 82U002 10,056 B2U002 700mA - 02 2,991 81 UI! 01 3,106 81 UO 01 04 5.982 81 UO 01 6,212 BI UOO1 IlL Test Report f: 79 175 SEC-EDB-25-"-06-E-uL-700-40K Initial Delivered Lumens: 11,704 SEC-EDG-25-°°-08-E-UL-525-40K Mounting Height: tO' (3Dm) A.F.G. Initial Delivered Lumens: 12.604 Initial FC at grade 06 8,871 8 2UOG1 9,212 82U082 : . Initial delivered lumens at 25'c 17771 "For more information on the IES DUO (Backllght-Uptight-alarel Rating visit: wve.ies.org!P0FIErmtas/TM-15-l1BagRatinsMdendum.pdl + CREE Canada: www.cree.com/canada T (800) 473-1234 F (800) 890-7507 SEC-EDG-4M-WM-02-E-UL—XX-700-40K Cree Edge TM Series TYPE SJ LEO Security WaLL Pack Luminaire Product Description CONTRACTOR TO SEE NOTES BELOW The Cree EdgeTM watt mount tuminaire has a slim, tow profile design. The luminaire end caps are made from rugged die cast aluminum with integral, weathertight LED driver compartments and high performance aluminum heat sinks specifically designed for LED applications. Housing is rugged aluminum. Includes a lightweight mounting box for installation over standard and mud ring single gang J-Boxes. Secures to wall with four 3116" 15mm) screws (by others). Conduit entry from top, bottom, sides and rear. Allows mounting for uptight or downUght. Designed and approved for easy through-wiring. Includes leaf/debris guard. Applications: General area and security lighting Performance Summary Patented NanoOpticO Product Technology Made in the U.S.A. of U.S. and imported parts CR1 Minimum 70 CR1 CCT: 4000K (+1- 300K), 5700K (+1- 500K) standard Limited Warranty?: 10 years on (uminaire/lO years on Colorfast DeLtaGuar& finish 'See ht:pj/Iightirrg.cice.comAvarronty for warrorrty terms CONTRACTOR TO VERIFY THAT FIXTURES CAN BE MOUNTED PER PLAN AND ALL NECESSARY HARDWARE IS SPECIFIED FOR INSTALLATION PRIOR Accessories TO PURCHASING FIeld-InstaUod Bird Spikes Hand-Held Remote XA-BRDSPK XA-SENSREM - For successful implementation of the programmable multi-level option. a minimum of one hand-held remote is required 18.3" (464mm) ) 4.1 11nm) jr 1== T111:11~ LED Count lxi 01 Dim. "A" Weight 02 9.9" 1251mm) 20 tbs. 19.1kg) 04 11.9" 1303mm) 22 tbs. 110.0kg1 06 13.9)353mm) 25 tbs. (11.3kg) 08 1 159" (404mm) 27 tbs. (12.2kg) 10 17.9" (455mm) 31 tbs. (14.1kg) 12 19.91505mm) 32 tbs. 114.5kg) CONTRACTOR TO VERIFY AND SPECIFY IF NOT UL Ordering Information Fvsmnte, S-EflR-2M-WM-OA--UL-SV-700 CONTRACTOR TO REFERENCE PLANS FOR COLOR DESIGNATION 02 E UL XX 700 40K 71-SEC-EDO WM Mounting LED Count Series Voltage Options nt Options 1001 WM 02 E Ut. BK 350 DIM 0-loVDimming edium Wall Mount 04 Universal Black 350mA - Central by others 2MB 06 120.277V BZ 525 - Refer to Dimming spec shoot for details Type II Medium w/BLS 08 UH Bronze 525mA - Can't exceed specified drive current 25 to Universal sv -Available with 20-BOLEDs F Fuse Type II Short 12 347-480V Silver 700 - Refer to ML spec sheet for availability with ML options ISO 34 wH 700mA - AvaitabLewithULvoltageonly Type II Short w/BLS 367V White -Available with 20-60 LEDs - When coda dictates Fusing, use time delay fuse 3M ML Multi-Level Type III Medium - Refer to ML spec sheet for details 3MB - Intended for downlight applications of 0" tilt Type III Medium w/BLS P Photocell am - Refer to ML spec sheet For availability with ML options Type IV Medium - Must specify UL or 34 voltage 4MB PML Programmable Multi-Level Type IV Medium w/BLS - Refer to PML spec sheet for details - Intended for downlight applications of 0" tilt 60K 4000K Color Temperature - Minimum 70 CR1 Color temperature per Luminaire c®Us US: tighting.creo.com/(ighting T 1800) 236-6800 F (262) 504-5415 Rev. Date: V2 07/28/2016 Canada: www.creo.com/canada CREW I.— T (800)473-1234 F (800) 890-7507 Cree EdgeTM LED Security Watt Pack Luminaire Electrical Data* LED Count (xl0l System Watts 120-480V Total Current - 120V 208V 240V 277V 347V [480V 350mA 02 25 0.21 0.13 0.11 0.10 0.08 0.07 04 46 0.36 0.23 0.21 0.20 0.15 0.12 06 66 0.52 0.31 0.28 0.26 0.20 0.15 08 90 0.75 0.44 0.38 0.34 0.26 0.20 10 110 0.92 0.53 0.47 0.41 0.32 0.24 12 130 1.10 0.63 0.55 0.48 0.38 0.28 525mA - 02 37 0.30 0.19 0.17 0.16 0.12 0.10 04 70 0.58 0.34 0.31 0.28 0.21 0.16 06 101 0.86 0.49 0.43 0.38 0.30 0.22 08 133 1.13 0.66 0.58 0.51 0.39 0.28 700mA 02 50 041 0.25 0.22 • [0.5 0.12 06 93 0.78 0.46 0.40 0.36 0.27 0.20 06 136 1.14 0.65 0.57 0.50 0.39 0.29 Eleetical data at 25C (77F1 Recommended Cree EdgeN Series Lumen Maintenance Factors (LMF)' Ambient Initial LMF 25K hr Projected LMF 50K hr Projectedt LMF 75K hr Calculated: LMF 100K hr CaLculated LMF 5C I41FI 1.04 0.99 0.97 0.95 0.93 10C l5071 1.03 0.98 0.96 0.94 0.92 15C 1597) 1.02 0.97 0.95 0.93 0.91 20C 16871 1.01 0.96 0.94 0.92 0.90 25C I7771 1.00 0.96 0.93 0.91 0.89 'Lumen maletenasce nature at 25C ore calculated perflt-21 based as LM-00 data and in-situ tamleulre testing ,in accordance with tE5NATM-21-1I, Projected Values represent leterpotatedvatue based an time durations thatare within sin times 101 the tE5NA t_M-80-08 total test duration lie hourel for the device under testing I1DUflie. the packaged LED chip) 'In accordance with tE5NATM.21-1I, Calculated Values represent time durations that exceed six times lEXI the IESNA U4-80-08 total test duration (in hears) for the device under testing ((Dull La. the packaged LED chip) Product Specifications CONSTRUCTION & MATERIALS Slim, low profile design Luminaire sides are rugged die cast aluminum with integral, weathertight LED driver compartment and high performance aluminum heat sinks specifically designed for LED applications Housing is rugged aluminum Furnished with low copper, light weight mounting box designed for installation over standard and mud ring single gang i-Boxes Luminaire can also be direct mounted to a wall and surface wired Secures to wall with four 3/16- (5mm) screws (by others) Conduit entry from top, bottom, sides, and rear Allows mounting for uptight or downlight Designed and approved for easy through-wiring Includes leaf/debris guard Exclusive Colorfast OeltaGuard5 finish features an E-Coat epoxy primer with an ultradurable powder topcoat, providing excellent resistance to corrosion, ultraviolet degradation and abrasion. Black, bronze silver and white are available Weight: See Dimensions and Weight Chart on page 1 ELECTRICAL SYSTEM Input Voltage: 120-277V or 347-480V, 50/60Hz, Class 1 drivers Power Factor 0.9 at full load Total Harmonic Distortion: c 20% at full load Integral weathertight i-Box with leads (wire nuts) for easy power hook up Integral 10kV surge suppression protection standard To address inrush current, slow blow fuse or type CID breaker should be used Maximum IOV Source Current: 20 LED (350mA): lOmA; 20LED (525 & 700 mA) and 40-120 LED: 0.15mA REGULATORY & VOLUNTARY QUALIFICATIONS ° cULus Listed Suitable for wet locations Meets FCC Part 15 standards for conducted and radiated emissions Enclosure rated 1P66 per IEC 60529 when ordered without P, PML or ML Options 10kV surge suppression protection tested in accordance with IEEE/ANSI C62.41.2 a Luminaire and finish endurance tested to withstand 5,000 hours of elevated ambient salt fog conditions as defined in ASTM Standard B 117 DLC qualified. Exceptions apply when ordered with full backlight control. Please refer to www.designlights.org/QPL for most Current information Dark Sky Friendly, IDA Approved. Please refer to www.darksky.org/ for most current information Meets Buy American requirements within ARRA CREW - US: lighting.cree.com/tighting T (800) 236-6800 F (262) 504-5415 Canada: www.cree.com/canada T (800) 473-1234 F (800) 890-7507 4M ITI. Test Report 0:78793 SEC-EOG-4M-"-06-E-UL-700-401( Initial Delivered Lumens: 11.607 SEC-EDG-4M-"-0B-E-UL-525-401( Mounting Height: 10' 130m) A.F.G. Initial Delivered Lumens: 11,835 lrtitiatFC at grade 4MB CSA Test Report 0:6449 ARE-EoG-6Ma--12-E-uL.-525-60K Initial Delivered Lumens: 13,155 SEC-EOG-41,18-"-08-E-UL-525-401( Mounting Height: 10' I3.0ml A.F.O. Initial Delivered Lumens: 8.915 Initial FC at grade Cree EdgeTM LED Security Watt Pack Luminaire Photometry All published lumiriaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project consult: http://lighting.cree.com/pruducts/outdoor/wall-mount/cree-edge-series-5 Type IV Medium Distribution LED Count Cxl 0) 4000K 5700K Initial Delivered Lumens' BUG Ratings" Per TM-i 5-li Initial Delivered Lumens' BUG Ratings" Per TM-15-i 1 350mA 02 2,138 BI_U001 2,220 01 UOC1 04 4,276 BI UO 01 4,440 01 UO 131 06 6,360 _t82 uo 02 6,581. B2 UO 02 08 8,454 B2 UO 02 8,779 B2 UO 02 10 10,542 B2U002 10,947 83U003 12 12,650 83U003 13,137 113UOG3 525mA 02 2,993 BIUOG1 13.108 BI uO GI 04 5,986 B2 UO 02 f6,216 f2 U0 02 06 8,876 B2UOC2 19.218 B2U002 08 11,835 83 UD 03 112.290 83 UO 03 700mA 02 3.656 81 UD 01 3,796 B1 uo 01 06 7,311 B2 UO 02 7,593 182 UO 02 06 10,842 B3UOG3 11.259 J B3UOG3 ' Initlaldelivered lumens at 25'C 177'Fl For more Information on the 1E5 BUG I0acktlght_Upsuht-oiarnl Rating visit: nsve.les.erg/POF/tirretasiTM'lS-llBegRetingsAddeedum.pdf Type IV Medium Distribution w/BLS LED Count Ixia) 4000K 5700K Initial Delivered Lumens' BUG Ratings" PerTM-15-11 Initial Delivered Lumens' BUG Ratings" PerTM-15-11 350mA - - 02 1,610 [ BOUOG1 1,672 80 UO Cl 04 3,221 Bi UO Cl 3.345 81 UO 01 06 6,776 Bi UO Cl 4,959 01 UO G1 08 6,368 BI UO 02 6,613 01 UO 02 10 7,941 81 UO 02 8,246 BI UO G2 12 9,529 BI UO G2 9,895 01 UQG2 525mA 02 2,254 80 UO 01 2,341 BO UO 01 04 4,509 Bi UO Cl 4,682 BI UO Cl 06 6,686 Bi UO 02 6,943 BI UO 02 08 8,915 81 UO 02 9,258 Bi UO 02 700mA 02 2,754 00 UO Cl [ 2,860 J BO UO 01 04 5,507 B1UO01 101 UO G2 06 8.167 BI U002 [8.481 ]BI U002 'Initiol delivered lumens at 25'C 177* F) For more information an the IES Bus IBackllght'Upiight-Giarel Rating visit: svew.ien.emJPOF/ErrntanFrM-15-llBagRatinguAddendumpdl © 2016 Cree, Inc. and/orone of its subsidiaries. All rights reserved. For Informational purposes only. Content is subject tochange. Patentwww.cree.cornlpatents. Cress, NanoOptice, and Colorfast DeltaCusrd5 are registered trademarks, and the Cree logo and Cree EdgeTN are trademarks of Cree, Inc. The UL Logo is a registered trademark of UL LLC.The DLC OPL logo Is registered trademarks of Northeast Energy Efficiency Partnerships, Inc. CREE US: tighting,croe.comltighting T (800) 236-6800 F (2621504-5415 Canada: www.cree.com/canada T (Boo) 473-1234 F (800) 890-7507 Shown with optional decal striping DOE LIGHTING FACTS Department of Energy has verified representative product test data and results in accordance with its Lighting Facts Program. Visit www.lightingtacts.com for specific catalog strings. LIGHT OUTPUT - XGBM Lumens (Nominal) Type FTA .Jype! ..!YaELI Watts i(Nominal) LW 14080 13840 1 15020 1 16560 140 SS 20180 18040 20700 23030 187 HO 26750 25460 29070 31810 300 LW 11450 11290 12220 13470 136 SS 16390 15170 17230 18750 188 HO 22240 20550 23510 25410 288 LED Chips are trequenhly updated therefore values may increase. GC SEE NOTES BELOW XGBM-FT-LED-SS-NW-UE-BRZ U Ui-U U2 GC TO VERIFY ALL INFORMATION BELOW ED AREA LRil1TS - This product, or selected versions of this product, meet the standards listed below. Please consult factory for your specific requirements. ROM S RC ARRA c®uS COMPLIANT wet LISTED wet location IP67 (M Fixtures comply with ANSI C136.31-2010 American National Standard for Roadway Ugliting Equipment - Luminaire Vibration 35 requirements. US patent 0574994 & 7828,456 and MX patent 29631 and US & Intl. patents pending SMARTTECTM THERMAL CONTROL - LSI drivers feature integral sensor which reduces drive current when ambient temperatures exceed rated temperature. OCCUPANCY SENSING (IIVIS) - Optional integral passive infrared motion sensor activates switching of luminaire light levels. High level light is activated and increased to full bright in 1-2 seconds upon detection of motion. Low light level (30% maximum drive current) is activated when target zone is absent of motion activity for -2 minutes and ramps down (10-15 seconds) to low level to allow eyes time to adjust. Sensor is located on the front of optical assembly and rotates with the optic. Sensor optic has a detection cone of approximately 45. Examples of detection - occurs 30' out from a 30' mounting height pole; occurs 20' out from a 20' mounting height pole. ENERGY SAVING CONTROL OPTIONS - DIM - 0-10 volt dimming enabled with controls by others. BLS - Bi-level switching responds to external line voltage signal from separate 120-277V controller or sensor (by others), with low light level decreased to 30% maximum drive current. LEDS - Select high-brightness LEDs in Cool White (5000K) or Neutral White (4000K) color temperature, 70 CR1. DISTRIBUTION/PERFORMANCE - Types 3, 5, FT and FTA available - field rotatable reflectors. HOUSING - Square, die-formed aluminum. Fully enclosed weather-tight housing contains factory prewired drivers and field connections. TOP-ACCESS COVER - Gasketed, tethered top-access cover provides ease of installation and allows for easy driver access. Four captive stainless-steel fasteners secure the top- access cover to the housing. OPTICAL UNIT - Clear tempered optical grade flat glass lens sealed to aluminum housing creates an 1P67 rated, sealed optical unit (includes pressure stabilizing breather). Optical unit can be easily field rotated in 90o increments. Directional arrow on optics allows alignment without the unit being energized. MOUNTING - 2-1/2" x 5-3/8" x 12" extruded aluminum arm mounting bracket shipped standard. Use with 5" traditional drilling pattern. Round Pole Plate (RPP2) required for mounting to 3"— 5" round poles. (See Accessory Ordering Information chart.) ELECTRICAL - Two-stage surge protection (including separate surge protection built into electronic driver) meets IEEE C62.41.2-2002, Location Category C. Available with universal voltage power supply 120-277VAC (UE - 50/60Hz input), and 347-480VAC. DRIVERS - Available in Low Watt (LW), Super Saver (SS) and High Output (HO) drive currents (Drive currents are factory programmed). Components are fully encased in potting material for moisture resistance. Driver complies with FCC 47 CFR part 15 RFI/EMI standard. OPERATING TEMPERATURE - -40°C to +50°C (-40°F to +122°0. FINISH - Fixtures are finished with LSI's DuraGrip® polyester powder coat finishing process. The DuraGrip finish withstands extreme weather changes without cracking or peeling. DECAL STRIPING - LSI offers optional color-coordinated decals in 9 standard colors to accent the fixture. Decals are guaranteed for five years against peeling, cracking, or fading. WARRANTY - LSI LEO fixtures carry a limited 5-year warranty. PHOTOMETRICS - Please visit our web site at www.lsi-industries.com for detailed photometric data. SHIPPING WEIGHT (IN CARTON) -Fixture -44.5 lbs (20 kg) Arm-S lbs. (2kg) arm LISTING - UL listed to U.S. and Canadian safety standards. Suitable for wet locations. For a list of the specific products in this series that are DLC listed, please consult the LED Lighting section of our websfte or the Design Lights website at www.designlights.org. Project Name I Fixture Type ________________________ 10/16/17 @2017 Catalog # xGBMFTLEDssNWUE1Z I LSI INDUSTRIES INC. LED AREA LIGHTS - (XGBM LUMINAIRE ORDERING INFORMATION ITYPICAL ORDER EXAMPLE: XGBIVI 5 LED HO CW UE WHT PCM I Prefix Distribution Light Drive Color Input Voltage Finish Optional Controls Optional Sensor/Options Source Current Temperature XGBM'- FT - Forward Throw LED LW - Low Watt CW - Cool White UE - Universal BLK - Black Wireless Control System2'3 Sensor LED FTA -Forward Throw SS - Super Saver (50001<) Voltage BRZ - Bronze (blaiik)- None IMS - Integral MotiorSensor° Greenbriar Automotive HO - High Output NW- Neutral White (120-277) GPT - Graphite PCM- Platinum Control System PCl120 - 120V Button-Type Photocell 3-Type III (4000K) MSV - Metallic Silver PCMH -HostiSatellite Platinum Control PC1208 - 208V Button-Type Photocell 5-Type V 347-480 PLP - Platinum Plus System PC1240 - 240V Button-Type Photocell SVG - Satin Verde CCV -Gold Control System PC1277 - 277V Button-Type Photocell Green GCMH -HosllSatellite Gold Control System PC1347 - 347V Button-Type Photocell WIlT - White DIM -0-10 volt dimming Optional Color Decals (required for satellite fIxtures) AISC - AirLink Synapse Control System options 45—Light Gold ALSCH •AirtinkSynapseControlSyslem - 881< - 8 Bracket (S and D180 only) 20—Charcoal Metallic 55—Black HosllSatetile TB - Terminal Block 94— Blue Metallic 59— Dark Green Stand-Alone Control 51— Dark Red (blank) - None 21—Tomato Red DIM- 0-10 volt dimming4 50—White (from external signal) 700 —Aztec Silver BLS - Bi-level Switching5 Metallic (from external signal - required I20-277V controls system voltage) IUMINAIRE EPA CHART2 - XGBM 8' Bracket 12" Bracket Single 2.3 2.4 D180" 4.7 4.8 1390' 4.7 T90" 12 Bracket 7.2 jTN120" Required 7.3 ago" 8.8 Note: House Side Shield adds to fixture EPA. Consult Factory. DIMENSIONS ACCESSORY ORDERING INFORMATION2 (Accessories are field installed) Description Order Number Description Order Number XGBM-HSS House Side Shield (Black only) 482002 BLK7 DFK208, 240 Double Fusing (208V. 240V1 DFK208.240' RPP2 - Round Pole Plate 1629148L1< DFK480 Double Fusing (480V) DFK4802 BKS-BO-WM-"-CLR - Wall Mount Plate 123111CLR FK347 Single Fusing (347V1 FK347' BKA-BO-RA-8-CLR - Radius Arm 169010CLR PMOS12O - 120V Pole-Mount Occupancy Sensor 518030CLR° BKU-BO-S-19-CLR - lipsweep Bracket for round or square poles 144191 CLR PMOS208/240- 208, 240V Pole-Mount Occupancy Sensor 534239CLR° FK120 Single Fusing (120V) FK120' NOR 77 - 277V Pole-Mount Occupancy Sensor 518029CLR° FK277 Single Fusing (277V) P1<277° PMOS480 - 480V Pole-Mount Occupancy Sensor 534240CLR° FOOTNOTES: Use with 5 traditional drilling pattern. For wireless controls information and accessories, sue Controls section. Requires a SiteManager and override switch. Not compatible with BLS or IMS option. Not compatible with IMS or BLS option. Not compatible with wireless controls system, DIM or IMS option. Not compatible with wireless controls system, DIM or BLS option. House Side Shields add to fixture EPA. Consult factory. Fusing must be located in the hand hate of pale. To be used with any of the PCM/GCM wireless controls systems in the fixture. Consult factory. Photocell must be ordered separately. 7 pin standard. See Accessories. 24" sq. (610 mm) (229 mm) (305 an 2-1/4" (57 mm) (35 mml (229 mm) E:1~ OPTIONAL INS 5/0" (16 mm) LIII 315/16" F(339 (99 mm) 135/16" I mmrl House Side Shield (482002BLK) Project Name i Fixture Type ________________________ 10/16/17 XGBM-FT-LED-SS-NW-UE-BRZ 02017 fa Catalog # L.Sl INDUSTRIES INC. LED AREA LIGHTS - (XGBM) BUG LISTING XGBM - Type 3 XGBM - Type FT fl.i,, P--i f'nlrn'Tnmn I -one I FR RUG Retina Drive Current ColorTemo. Lumens Waits LER BUG Rating HO CW 26.754 300 89 83-UO-G3 CW-HSS 17,316 288 60 B2-UO-G2 NW 22,240 289 77 B3-UO-G2 NW-HSS 13,941 288 48 82-UO-G2 LW CW 14,082 140 100 82-UO-G2 CW-HSS 9205 137 67 B1-1.10-132 NW 11,451 137 84 B2-UO-G2 NW-HSS 7513 136 1 55 131-1.10-02 SS CW 20181 187 108 B3-11.10-132 CW-HSS 13,034 187 70 B2-UO-G2 NW 16,394 189 87 83-UO-G2 NW-HSS 10,384 189 ••• B2-UO-G2 XGBM - Type 5 fl.i,rn ',ni tnlnTn,n • I WiIti IER RUG Ratins HO CW 25,464 300 1 85 B4-UO-G2 NW 20,549 288 71 84-1.10-132 LW CW 13,842 140 99 B3-UO-G2 NW 11,291 136 83 B3-1.10-132 SS CW 18,044 186 97 84-UO-G2 NW 1 15,173 189 80 B4-UO-G2 XGBM - Type FTA I'..I.. T..... * I .rn.rn,* %AI*II* I FR RIIR Ritinn HO CW 31,808 301 1 106 B4-UO-G4 CW-HSS 20,838 288 72 83-tJO-G3 NW 25,407 289 88 83-UO-G3 NW-HSS 16,855 289 58 B3-UO-G3 LW CW 16,560 140 118 83-UO-G2 CW-HSS 11,440 137 84 B2-1.10-132 NW 13,473 136 99 B3-1.10-132 9277 136 68 B2-UO-02 SS CW 23,033 187 123 83-UO-G3 CW-HSS 15,213 187 11 B3-UO-G2 NW 18.752 189 ..99. 83-1.10-133 NW-HSS 12,516 189 66 132-1.10-133 HO CW 29,070 301 97 82-UO-G4 CW-HSS 20,964 288 73 B1-UO-G4 NW 23,512 289 81 B2-UO-G4 NW-HSS 17,191 289 60 B1-UO-G3 LW CW 15,019 141 IQL. B1-UO-G3 CW-HSS 11,519 137 84 B1-UO-G3 NW 12,217 136 90 B1-1.10-133 NW-HSS 9365 136 69 B1-UO-G3 SS CW 20,700 187 111 82-UO-G3 CW-HSS 15,273 187 r 81-UO-G3 NW 17,230 189 91 B1-UO-G3 NW-HSS 12,597 189 67 B1-UO-G3 * Color Temperature: NW-4000K, CW-5000K Project Name Catalog # XGBMFTLEDSSNWUEBRZ Fixture Type 10/16/17 @2017 LSI INDUSTRIES INC. AirLink" enabled by Synapse® Wireless Lighting Controller The AirLink integrated controller is a California Title 24 compliant lighting controller that provides real-time light monitoring and control with utility-grade power monitoring. It includes a 24V sensor input and power supply to connect up to two (2) sensors into the outdoor AirLink wireless lighting system. The wireless integrated controller and twist lock controller are compatible with this fixture. Features 2% Utility Grade Power Monitoring Up to 80% Savings through smart dimming True On/Off functionality via switched relay Seamlessly integrates into the outdoor AirLink wireless lighting control solution & Self-healing Mesh Networking Relay closes on power loss Supports a wide range of LED drivers and fixtures Class 1 / Class 2 0-10V Dimming Control Direct Connect up to two (2) to 24V Occupancy Sensors and Photocells (consult sales for compatible list) Secure, over-the-air upgrades to support future enhancements Excellent RF Range - 1,000ft LoS between controllers Available in a metal cased version with quick connect terminal blocks Lights default to on for safety Specifications Regulatory Approvals FCC, IC, CE certified cULus Listed California Title 24 compliant Power and Performance Operating environmental: -40°F to 131°F (-40°C to 55°C) Input power: 100-277 VAC +1- 10% (Max 305V)47/64 Hz Switched output: Default ON; Zero Cross Switching Load rating: 5A @ 100V to 277V (+1- 10%) Dimming: 0-10V control; Output: Class 1/2 - 20mA Source Max / 50mA Sink Max Power monitoring: Utility grade - 2% accuracy Sensors inputs: 0-10V (photocell sensors), 0-24V (all other sensors); Sensor power supply: 24VDC © 50mA Other Dimensions: 8.2" Lx 2.3" W x 1.3" H (209mm L x 59mm W x 33mm H) without antennas Radio: SNAP 2.4 GHz; 802.15.4; +20 dBm Transmit Power; -105 dBm Receive Sensitivity Warranty: 5 years Contact LSI Controls Sales Aft Q Support More information j ® controls.support@llsi-industries.com For more information on AirLink, visit our controls.sales@lsi-industries.com 1 (800) 436-7800 (support, option 8) vW websiteatwww.Isi-airlink.com/airlink LSI Industries Inc. 10000 Alliance Rd. Cincinnati OH 452112. wwwJsi-industrieacom . (513)372-3200. @L.Si Industries Inc. All Rights Reserved. 10/12/17 LED AREA LIGHTS - (XGBM) Shown with optional decal striping DOE LIGHTING FACTS Department of Energy has verified representative product test data and results in accordance with its Lighting Facts Program. Visit www.lightingtacts.com for specific catalog strings. LIGHT OUTPUT - XGBM Lumens (Nominal) ja Type j.. 1 JYafL I Type FIA Watts Nominal' LW 14080 13840 15020 16560 140 SS 20180 18040 20700 23030 187 HO 26750 25460 29070 31810 300 LW 11450 11290 12220 13470 136 SS 16390 15170 17230 18750 188 HO 22240 20550 23510 25410 288 LED Chips are frequently updated therefore values may Increase. GC SEE NOTES BELOW XGBM-5-LED-LW-NW-UE-BRZ GC TO VERIFY ALL INFORMATION BELOW UU3 US patent D574994 & 7,828456 and MX patent 29631 and US & Int'l, patents pending SMARTTECTM THERMAL CONTROL - LSI drivers feature integral sensor which reduces drive current when ambient temperatures exceed rated temperature. OCCUPANCY SENSING (IMS) - Optional integral passive infrared motion sensor activates switching of luminaire light levels. High level light is activated and increased to full bright in 1-2 seconds upon detection of motion. Low light level (30% maximum drive current) is activated when target zone is absent of motion activity for -2 minutes and ramps down (10-15 seconds) to low level to allow eyes time to adjust. Sensor is located on the front of optical assembly and rotates with the optic. Sensor optic has a detection cone of approximately 45. Examples of detection - occurs 30' out from a 30' mounting height pole; occurs 20' out from a 20' mounting height pole. ENERGY SAVING CONTROL OPTIONS - DIM - 0-10 volt dimming enabled with controls by others. BLS - Bi-level switching responds to external line voltage signal from separate 120-277V controller or sensor (by others), with low light level decreased to 30% maximum drive current. LEDS - Select high-brightness LEDs in Cool White (5000K) or Neutral White (4000K) color temperature, 70 CR1. DISTRIBUTION/PERFORMANCE - Types 3, 5, FT and FTA available - field rotatable reflectors. HOUSING - Square, die-formed aluminum. Fully enclosed weather-tight housing contains factory prewired drivers and field connections. TOP-ACCESS COVER - Gasketed, tethered top-access cover provides ease of installation and allows for easy driver access. Four captive stainless-steel fasteners secure the top- access cover to the housing. OPTICAL UNIT - Clear tempered optical grade flat glass lens sealed to aluminum housing creates an IP67 rated, sealed optical unit (includes pressure stabilizing breather). Optical unit can be easily field rotated in 900 increments. Directional arrow on optics allows alignment without the unit being energized. MOUNTING - 2-1/2" x 5-3/8" x 12" extruded aluminum arm mounting bracket shipped standard. Use with 5" traditional drilling pattern. Round Pole Plate (RPP2) required for mounting to 3"— 5" round poles. (See Accessory Ordering Information chart.) ELECTRICAL - Two-stage surge protection (including separate surge protection built into electronic driver) meets IEEE C62.41.2-2002, Location Category C. Available with universal voltage power supply 120-277VAC (LIE - 50/60Hz input), and 347-480VAC. DRIVERS - Available in Low Watt (LW), Super Saver (SS) and High Output (HO) drive currents (Drive currents are factory programmed). Components are fully encased in potting material for moisture resistance. Driver complies with FCC 47 CFR part 15 RFI/EMI standard. OPERATING TEMPERATURE - -40°C to +50°C (-40°F to +122°0. FINISH - Fixtures are finished with LSI's DuraGrip® polyester powder coat finishing process. The DuraGrip finish withstands extreme weather changes without cracking or peeling. This product, or selected versions of this product, meet the standards DECAL STRIPING - LSI offers optional color-coordinated decals in 9 standard colors to listed below. Please consult factory for your specific requirements. accent the fixture. Decals are guaranteed for five years against peeling, cracking, or fading. RHS FC AR R A WARRANTY - LSI LED fixtures carry a limited 5-year warranty. USTEII COMPUAtIT RaCumçait wet location IP67 PHOTOMETRICS - Please visit our web site at www.lsi-industries.com for detailed photometric data. Rnturea comply w%th Mist C136.31-2010 medcon National standard tar Roadway Lighting SHIPPING WEIGHT (IN CARTON) -Fixture -44.5 lbs (20 kg) Arm-S lbs. (2kg) arm Equipment -Luminaire Vibration 3O requirements. LISTING - UL listed to U.S. and Canadian safety standards. Suitable for wet locations. For a list of the specific products in this series that are DLC listed, please consult the LED Lighting section of our website or the Design Lights website at www.designlights.org. @ Project Name i Fixture Type ______________________ 10116/17 02017 Catalog # XGBM-5-LED-LW-NW-UE-BRZ LSI INDUSTRIES INC. LED AREA LIGHTS - (XGBM LUMINAIRE ORDERING INFORMATION ETYPICAL ORDER EXAMPLE- XGBM 5 LED HO CW UE WHT PCIVI Prefix Distribution Light Drive Color Input Voltage Finish Optional Controls Optional Sensor/Options Seorce Current Temnerature XGBM' - FT - forward Throw LED LW - Low Watt CW - Cool White UE- Universal BILK - Black Wireless Control System 2.3 Sensor LED FTA - Forward Throw SS - Super Saver (5000K) Voltage BRZ - Bronze (blank)- None IMS - Integral MofiorSensor° Greenbrier Automotive HO - High Output NW - Neutral White (120-277) GPT - Graphite PCM- Platinum Control System PC1120 - 120V Button-Type Photocell 3-Type III (4000K) MSV - Metallic Silver PCMH-HostlSatetite Flat num Control PC1208 - 208V Button-Type Photocell 5-Type V 347-480 PLP - Platinum Plus System PC1240 - 240V Button-Typo Photocell SVG - Satin Verde 0CM -Gold Control System PC1277 - 277V Button-Type Photocell Green GCMH - HusllSatellite Gold Control System PC1347 - 347V Button-Type Photocell WHT - White DIM -0-10 volt dimming Optional Color Decals (required for satellite fixtures) M.SC - MrthikSyoapseCmlrolSyslem 45-Light Gold ALSCH - AhtinkSynapseControlSyslem - .Options_ BBK -8' Bracket (S and D180 only) Charcoal Metallic 55-Black Hssstslle TB - Terminal Block 94- Blue Metallic 59- Dark Green Stand-Alone Control 5 - Dark Red (blank) - None Tomato Red DIM - 0-10 volt dimming 50-White (from external signal) 700 -Aztec Silver BLS - Bi-level Switching5 Metallic (from external signal- required 120-271V controls system voltage) I UJMINAIRE EPA CHARP -XGBM B" Bracket 12" Bracket Single 2.3 2.4 0180 4.7 4.8 _______ 4-7 igo" 12Bracke 7.2 Required 7.3 or*TN120 8.8 Note: House Side Shield adds to fixture EPA. Consult Factory. DIMENSIONS CCESSORY ORDERING INFORMATION2 (Accessories are field installed) Description Order Number Description Order Number XGBM-HSS House Side Shield (Black only) 482002 BLK' DFK208. 240 Double Fusing (208V, 240V) DFl<8.2408 RPP2- Round Pole Plate 162914BLl< DFI(480 Double Fusing 1480V) 0FK480' BKS-BO-WM-"-CLR -Wall Mount Plate 123111CLR FK347 Single Fusing (347V) FK3475 BKA-BO-RA-8-CLR - Radius Arm 1690I0CLR PMOS120 - 120V Pole-Mount Occupancy Sensor 518030CLR9 BKU-BO-S-19-CLR- Upsweep Bracket for round or square poles 144191 CLR PMOS2O&240 - 208,240V Pole-Mount Occupancy Sensor 534239CLR5 FK120 Smote Fusing (120V) FK120a PM05277 - 277V Pole-Mount Occupancy Sensor 518029CLR9 FK277 Single Fusing (277V) FK277' PMOS480 - 480V Pole-Mount Occupancy Sensor 534240CLRa FOOTNOTES: 1-Use with 5 traditional drilling pattern. For wireless controls information and accessories, see Controls section. Requires a SiteManager and override switch. Not compatible with BLS or IMS option. Not compatible with MS or BLS option. Not compatible with wireless controls system, DIM or IMS option. Not compatible with wireless controls system, DIM or BLS option. House Side Shields add to fixture EPA. Consult factory. Fusing must be located in the hand hole of pub. To be used with any of the PCM/GCM wireless controls systems In the fixture. Consult factory. Photocell must be ordered separately. 7 pin standard. See Accessories. 24" sq. (6lOmm) (229 mm) 315115" (99 mm) 135116'j I 339 mm) I 2_1/4u (57mm) —ø.- (229 mm) I 1-318' a5 mm) r OPTIONAL INS T 518" (16 mm) House Side Shield (482002BLK) mm) Project Name Catalog A XGBM-5-LED-LW-NW-UE-BRZ Fixture Type 10/16/17 © 2017 LSI INDUSTRIES INC. LED AREA LIGHTS - (XGBM) BUG LISTING XGBIVI - Type 3 XGBIVI - Type FT firiup Current CalnrTemn* Lumens Watts LR RUG Ratinu Drive Current CnlnrTemn. Lumens Watts LEA BUG Ratina HO CW 26,754 300 89 B3-UO-03 CW-HSS 17,316 288 60 B2-UO-G2 NW 22,240 289 77 B3-UO-G2 NW-HSS 13,941 288 48 132-1.10-132 LW CW 14,082 140 100 132-1.10-132 CW-HSS 9205 137 1 67 B1-UO-G2 NW 11,,451 137 iT B2-UO-G2 NW-HSS 7513 136 55 B1-UO-G2 SS CW 20181 187 108 B3-UO-G2 CW-HSS 13,034 187 70 B2-UO-G2 NW 16,394 189 87 B3-UO-G2 NW-HSS 10,384 189 - B2-UO-G2 HO CW 29,070 301 97 B2-UO-G4 CW-HSS 20,964 288 73 B1-UO-G4 NW 23,512 289 81 B2-UO-G4 NW-HSS 17,191 289 60 B1-1,10-133 LW CW 15.019 141 107. B1-UO-G3 CW-HSS 11,519 137 84 B1-UO-G3 NW 12,217 136 90 B1 -1.10-133 9365 136 69 B1-UO-G3 SS CW 20,700 187 111 82-UO-03 CW-HSS 15,273 187 82 B1-UO-G3 NW 17,230 189 91 B1-UO-G3 NW-HSS 12,597 189 17 B1-UO-G3 XGBIVI - Type 5 * Color Temperature: NW-4000K, CW-50001< flrk,p t'.u,ryent r.nlnr Temn • I urmenu Watt I ER RUG Retina HO _______ CW 25,464 300 851 B4-UO-G2 NW 20,549 288 7TJ 84-UO-G2 LW _______ CW 13,842 140 B3 -Gr NW 11,291 136 83 83-UO-G2 SS _______ CW 18,044 186 i'T B4-UO-G2 NW 15,173 189 1 80 B4-UO-G2 XGBIVI- Type FTA flpiu* t'.uurrent tnInr Temn • I nmenu Watts LER RUG Retina CW 31,808 301 106 134-UO-134. HO CW-HSS 20,838 288 72 B3-UO-G3 NW 25,407 289 88 B3-UO-G3 NW-HSS 16,855 289 58 B3-UO-G3 LW CW 16,560 140 iTh 133-UO-G2 CW-HSS 11,440 137 84 B2-UO-G2 NW 13,473 136 99 B3-UO-G2 NW-HSS 9277 136 68 132-UO-132 SS CW 23,033 187 123 B3-UO-G3 CW-HSS 15,213 187 IT B3-UO-G2 NW 18.752 189 99 83-IJO-G3 NW-HSS 12,516 1 189 66 B2-UO-G3 fa Project Name i Fixture Type I 10/16/17 02017 Catalog # XGBM-5-LED-LW-NW-UE-BRZ I LSI INDUSTRIES INC. AirLink" enabled by Synapse® Wireless Lighting Controller The AirLink integrated controller is a California Title 24 compliant lighting controller that provides real-time light monitoring and control with utility-grade power monitoring. It includes a 24V sensor input and power supply to connect up to two (2) sensors into the outdoor AirLink wireless lighting system. The wireless integrated controller and twist lock controller are compatible with this fixture. Features 2% Utility Grade Power Monitoring Up to 80% Savings through smart dimming True On/Off functionality via switched relay Seamlessly integrates into the outdoor AirLink wireless lighting control solution & Self-healing Mesh Networking Relay closes on power loss Supports a wide range of LED drivers and fixtures Class 1/Class 2 0-10V Dimming Control Direct Connect up to two (2) to 24V Occupancy Sensors and Photocells (consult sales for compatible list) Secure, over-the-air upgrades to support future enhancements Excellent RF Range - 1 ,000ft LOS between controllers Available in a metal cased version with quick connect terminal blocks Lights default to on for safety Specifications Regulatory Approvals FCC, IC, CE certified cULus Listed California Title 24 compliant Power and Performance Operating environmental: -40°F to 131°F (-40°C to 55°C) Input power: 100-277 VAC +/- 10% (Max 305V)47/64 Hz Switched output: Default ON; Zero Cross Switching Load rating: 5A © 100V to 277V (+1- 10%) Dimming: 0-10V control; Output: Class 1/2 - 20mA Source Max I 50mA Sink Max Power monitoring: Utility grade - 2% accuracy Sensors inputs: 0-10V (photocell sensors), 0-24V (all other sensors); Sensor power supply: 24V0C © 50mA Other Dimensions: 8.2" Lx 2.3" W x 1.3" H (209mm Lx 59mm W x 33mm H) without antennas Radio: SNAP 2.4 GHz; 802.15.4; +20 dBm Transmit Power; -105 dBm Receive Sensitivity Warranty: 5 years Contact LSI Controls Support More information ij Sales a controls.support@lsi-industries.com 0 For more information on AirLink, visit our controls T .sales@Isi-industries.com 1 (800) 436-7800 (support, option 8) websiteatwww.isi-airlink.com/airlink LSI Industries Inc. 10000 Alliance Rd. Cincinnott OH 45242• www.Isl-industriescom . (513)372-3200• ®LSI Industries Inc All Rights Reserved. 10/12/17 SAN DIEGO REGIONAL I OFFICE USE ONLY HAZARDOUS MATERIALS IPLAN I RECORD ID #______________________________________ CHECK # acce QUESTIONNAIRE BP DATE I I Bsines s N ame Businss qontact j'& WM Telephone # - % Ik it* Project Address c City J ø(1 Z* Code Z I APN# ailing ddas M A QJk'I liuk State M C- Zip Code Plan F ile# I ctCon rc t Applicant E-mail Telephone # -It J-SI-75M The following questions represent th&racility's activities, NOT the specific project description. Indicate by circling the item, whether your business will use, process, or store any any 01 tile items are nt must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Occupancy Rating: Facility's Square Footage (including proposed project): Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 13. Corrosives Compressed Gases 6. Oxidizers 10. Cryogenics 14. Other Health Hazards Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials 6 None of These. Flammable Solids 8. Unstable Reactives 12. Radioactives If the answer to any of the Diego, CA 92123. Call (858) 505-6700 prior to the issuance of a building permit FEES ARE REQUIRED Project Completion Date: Expected Date of Occupancy: YES NO (for new construction or remodeling projects) 0 ..-1'ls your business listed on the reverse side of this form? (check all that apply). 0 J' Will your business dispose of Hazardous Substances or Medical Waste in any amount? 0 )2" Will your business store or handle Hazardous Substances in quantities greater than or equal to 55 gallons, 500 pounds and/or 200 cubic feet? 0 Will your business store or handle carcinogens/reproductive toxins in any quantity? 0 .' Will your business use an existing or install an underground storage tank? 0 ' Will your business store or handle Regulated Substances (CalARP)? 0 Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? 0 J Will your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to or areater than 1.320 aallons? (California's Aboveround Petroleum Storage Act). 0 CalARP Exempt Date Initials o CalARP Required Date Initials El CalARP Complete Date Initials PART Ill: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT (APCD): Any YES* answer requires a stamp from APCD 10124 Old Grove Road, San Diego, CA 92131 apcdcompsdcounty.ca.gov (858) 586-2650). [*No stamp required if Qi Yes and Q3 Yes and 04-Q6 No]. The following questions are intended to identify the majority of air pollution issues at the planning stage. Projects may require additional measures not identified by these questions. For comprehensive requirements contact APCD. Residences are typically exempt, except - those with more than one building* on the property; single buildings with more than four dwelling units; townhomes; condos; mixed-commercial use; deliberate burns; residences forming part of a larger project. [Excludes garages & small outbuildings.] YES Np.. 0 .4J Will the project disturb 160 square feet or more of existing building materials? 0 - Will any load supporting structural members be removed? Notification may be required 10 working days prior to commencing demolition. 0 0 (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Has an asbestos survey been performed by a Certified Asbestos Consultant or Site Surveillance Technician? 0 0 (ANSWER ONLY IF QUESTION 3 IS YES) Based on the survey results, will the project disturb any asbestos containing material? Notification , may be required 10 working days prior to commencing asbestos removal. 0 ,.J Will the project or associated construction equipment emit air contaminants? See the reverse side of this form or APCD factsheet (www.sdaocd.org/info/facts/permits.odf) for typical equipment requiring an APCD permit. 0 0 (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located within 1,000 feet of a school Briefly describe business activities: I Briefly describe proposed project: (t)rvasri bAUkIA%II I 4ecre Linder penaltypT perjury that to the best of my knowledge and made herthfi are true and correct. / i / Name of Owner or Authorized Agent Signature of Owner or Authorized Agent Date FOR OFFICAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION:_______________________________________________________________________ BY: DATE: EXEMPT OR NO FURTHER INFORMATION REQUIRED FOR BUILDING PERMIT BUT NOT FOR occucv -_RELEASED RELEASED FOR occucv COUNTYHMD* APCD COUNTY-HMD APCD COUNTY-HMD APCD *A stamp in this box only exempts businesses from completing or updating a Hazardous Materials Business Plan. Other permitting requirements may still apply. HM-9171 (08/15) County of San Diego - DEH - Hazardous Materials Division ENCINA WASTEWATER AUTHORITY INDUSTRIAL WASTEWATER DISCHARGE PERMIT INCKI SCREENING SURVEY AUMMY 6200 Avenida Encinas, Carlsbad, CA 92011 Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinajpa.com it) The commercial enterprises listed below are a partial listing of businesses that are exempt from industrial wastewater discharge permitting under normal operating conditions. They are exempt because (a) they discharge no process wastewater (i.e., they only discharge sanitary wastewater with no pollutants exceeding any local limits), and (b) they have no potential to negatively impact the EWPCF or other wastewater treatment plants in the ESS. Any questions regarding exemptions should be referred to EWA Source Control staff. Automobile Detailers Barber/Beauty Shops Business/Sales Offices Cleaning Services Carpet/Upholstery Childcare Facilities Churches Community Centers Consulting Services Contractors Counseling Services Educational Services (no auto repair/film developing) Financial Institutions/Services Fitness Centers Gas Stations (no car wash/auto repair) Grocery Stores (no film developing) Residential based Businesses Hotels/Motels (no laundry) Laundromats Libraries Medical Offices (no x-ray developing) Mortuaries o Museums Nail Salons Nursing Homes Office Buildings (no process flow) Optical Services Pest Control Services (no pesticide repackaging for sale) Pet Boarding/Grooming Facilities Postal Services (no car wash/auto repair) Public Storage Facilities Restaurants/Bars Retail/Wholesale Stores (no auto repair/film developing) Theaters (Movie/Live) CERTIFICATION STATEMENT / certify that the information above is true and correct to the best of my knowledge. Signatur f%__1t —_ Print Name:LIAtY1AA P&k'!kt4 DATE:. 'f)o Facility ContactL JL¼ Title:S9 ENCINA WASTEWATER AUTHORITY 6200 AVENIDA ENCINAS, CARLSBAD, CA Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinaiDa.com Page 2 of 2 NJ J (City of Carlsbad CLIMATE ACTION PLAN CONSISTENCY CHECKLIST B-50 Development Services Building Division 1635 Faraday Avenue (760) 602-2719 www.carlsbadca.gov PURPOSE This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their projects. The completed checklist must be included in the building permit application. It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as specified by the ordinances. NOTE: The following type of permits are not required to fill out this form . Patio •• Decks •• PME (w/o panel upgrade) •:• Pool A If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, an explanation must be provided to the satisfaction of the Building Official. A Details on CAP ordinance requirements are available on the city's website. .4 A CAP Building Plan template (form B-55) shall be added to the title page all building plans. This template shall be completed to demonstrate project compliance with the CAP ordinances. Refer to the building application weboacie and download the latest form. Application Information Project Name/Building Permit No.: Property Address/APN: Applicant Name/Co.: Applicant Address: Contact Phone: ifflm 192 ffl.4- 11-M-501WIN 11 Contact information of person completing this checklist (if different than above): Name: Contact Phone: Company name/address: Contact Email: q,-1 Cimlt% Applicant Signature: Date: B-50 Page 1 of 6 Revised 08/19 Gity of Carlsbad Climate Action Plan Consistency Checklist Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project. For alterations and additions to existing buildings, attach Building Permit Valuation worksheet. Building Permit Valuation (BPV) from worksheet: $________________ Construction Type Complete Section(s) Notes: A high-rise residential building is 4 or more stories, including a Residential Low-rise High-rise mixed-use building in which at least 20% of its conditioned floor area is residential use New construction 2A, 3A, 4A 18, 2B, 38,4A 0 Additions and alterations: BPV < $60,000 N/A N/A All residential additions and alterations BPV 2t $60,000 IA 4A 4A 1-2 family dwellings and townhouses with attached garages Electrical service panel upgrade only only *Multi-family dwellings only where interior finishes are removed D BPV ~t $200,000 IA, 4A* 18, 4A* and significant site work and upgrades to structural and mechanical,electrical,and/orplumbingsystemsareproposed Nonresidential New construction Alterations: c? ) \EL BPV a $200,000 or additions ~! 1, square feet 0 BPV 2! $1,000,000 0 > 2,000 sq. ft. new roof addition 18,28, 3B, 48 and 5 5 18, 2B, 5 I Building alterations of 2! 75% existing gross floor area 2B, 5 I 1 B also applies if BPV ~t $200,000 CAP Ordinance Compliance Checklist Item Check the appropriate boxes, explain all not applicable and exception items, and provide supporting calculations and documentation as necessary. 1. Energy Efficiency Please refer to Carlsbad Municipal Code (CMC) sections 18.21.155 and 18.30.190, and the California Green Building Standards Code (CALGreen) for more information when completing this section. A 0 Residential addition or alteration ~ $60,000 building permit valuation. 0 N/A______________________________ See CMC section 18.30.190. 0 Exception: Home energy score 2: 7 (attach certification) Year Built Single-family Requirements Multi-family Requirements Before 1978 Select one: Duct sealing 0 Attic insulation 0 Cool roof 0 Attic insulation 1978 and later Select one: Lighting package 0 Water heating Package Between 1978 and 1991 Select one: Duct sealing 0 Attic insulation 0 Cool roof 1992 and later Select one: Lighting package 0 Water heating package B. 0 Nonresidential* new construction or alterations $200,000 building permit valuation, or additions? 1,000 square feet \J N/A______________________________ Updated 8/15/2019 2 City of Carlsbad Climate Action Plan Consistency Checklist See CMC 18.21 .155 and CALGreen Appendix A5, Division A5.2 — Energy Efficiency. A5.203.1.1 Choose one: 0.1 Outdoor lighting 0.2 Warehouse dock seal doors 0.3 Restaurant service water heating (comply with California Energy Code section 140.5, as amended) 0 N/A______________________________ 0.4 Daylight design PAFs 0.5 Exhaust air heat recovery A5.203.1.2.1 Choose one as applicable: 0.95 Energy budget 0.90 Energy budget 0 N/A____________________________ A5.211.1** On-site renewable energy 0 N/A______________________________ A5.211.3** Green power (if offered by local utility provider, 50% minimum renewable sources) 0 N/A____________________________ A5.212.1 Elevators and escalators 0 N/A___________________________ A5.213.1 D Steel framing 0 N/A________________________ * Includes hotels/motels and high-se residential buildings ** For alterations ~: $1000000 BPV and affecting >75% existing gross floor area, or alterations that add 2,000 square feet of new roof addition: comply with CMC 18.30.130 instead. 2. Photovoltaic Systems 0 Residential new construction (for low-rise residential building permit applications submitted after 1/1/20). Refer to 2019 California Energy Code section 150.1(c)14 for requirements. Notes: 1) High-rise residential buildings are subject to nonresidential photovoltaic requirement (213 below) instead. 2) If project includes installation of an electric heat pump water heater pursuant to CMC 18.30.150(B) (high-rise residential) or 18.30.170(B) (low-rise residential), increase system size by .3kWdc if PV offset option is selected. Floor Plan ID (use additional sheets if necessary) CFA #d.u. Calculated kWdc* Exception - Total System Size: kWdc kWdc = (CFAx.572) / 1,000 + (1.15 x #d.u.) *Formula calculation where CFA = conditional floor area, #du = number of dwellings per plan type If proposed system size is less than calculated size, please explain. 0 Nonresidential new construction or alterations 2$1,000,000 BPV and affecting 275% existing floor area, or addition that increases roof area by 22,000 square feet Please refer to CMC section 18.30.130 when completing this section. Note: This section also applies to high-rise residential and hotel/motel buildings. Choose one of the following methods: Gross Floor Area (GFA) Method GFA: Mm. System Size: kWdc If < 10,000s.f. Enter: 5 kWdc If ~! 10,000s.f. calculate: 15 kWdc x (GFN10,000) ** **Round building size factor to nearest tenth, and round system size to nearest whole number. 0 Time- Dependent Valuation Method Updated 8/15/2019 City of Carlsbad Climate Action Plan Consistency Checklist Annual TDV Energy use:*** x.80= Mm. system size: kWdc ***Attach calculation documentation using modeling software approved by the California Energy Commission. 3. Water Heating A E Residential and hotel/motel new construction Please refer to CMC sections 18.30.150 and 18.30.170 when completing this section. DFor systems serving individual dwelling units choose one: El Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise residential only) O Heat pump water heater AND PV system .3 kWdc larger than required in CIVIC section 18.30.130 (high rise residential hotel/motel) or CA Energy Code section 150.1(c) 14 (low-rise residential) E] Heat pump water heater meeting NEEA Advanced Water.Heating Specification Tier 3 or higher El Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors 0 Exception: 0 For systems serving multiple dwelling units, install a central water-heating system with all of the following: O Gas or propane water heating system O Recirculation system per CIVIC 18.30.150(B) (high-rise residential, hotel/motel) or CIVIC 18.30.170(B) (low- rise residential) M Solar water heating system that is either: 0.20 solar savings fraction 0.15 solar savings fraction, plus drain water heat recovery 0 Exception: B. Nonresidential new construction Please refer to Carlsbad Ordinance CIVIC section 18.30.150 when completing this section. o Water heating system derives at least 40% of its energy from one of the following (attach documentation): 0 Solar-thermal 0 Photovoltaics 0 Recovered energy []Water heating system is (choose one): 0 Heat pump water heater 0 Electric resistance water heater(s) DSolar water heating system with .40 solar savings fraction 0 Exception: Updated 8/15/2019 4 City of Carlsbad Climate Action Plan Consistency Checklist 4. Electric Vehicle Charging A El Residential New construction and major alterations* Please refer to Carlsbad Ordinance CIVIC section 18.21 .140 when completing this section. ElOne and two-family residential dwelling or townhouse with attached garage: [—]One EVSE Ready parking space required 0 Exception: fl Multi-family residential: 0 Exception: Total Parking Spaces Proposed EVSE Spaces Capable Ready Installed Total Calculations: Total EVSE spaces =10 x Total parking (rounded up to nearest whole number) EVSE Installed = Total EVSE Spaces x .50 (rounded up to nearest whole number) EVSE other= Total EVSE spaces - EVSE Installed (EVSE other may be Capable," Ready' or "Installed.") *Major alterations are: (1) for one and two-family dwellings and townhouses with attached garages, alterations have a building permit valuation ~ $60,000 or include an electrical service panel upgrade; (2) for mulfamiIy dwellings (three units or more without attached garages), alterations have a building permit valuation ~: $200,000, interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed. - B. [• Nonresidential new construction (includes hotels/motels) 0 Exception: Total Parking Spaces EVSE Sp ble Read Installed Total 10 Calculation: Refer to the table below: Total Number of Parking Spaces provided Number of required EV Spaces Number of required EVSE Installed Spaces 0.9 1 1 O 10-25 2 1 26-50 4 2 9 51.75 6 3 9 76-100 9 . 5 9 101-150 12 6 151-200 17 9 9 201 and over 10 percent of total 50 percent of Required EV Spaces Updated 8/15/20.19 City of Carlsbad Climate Action Plan Consistency Checklist 5. 0 Transportation Demand Management (TDM): Nonresidential ONLY An approved Transportation Demand Management (TOM) Plan is required for all nonresidential projects that meet a threshold of employee-generated ADT. City staff will use the table below based on your submitted plans to determine whether or nor your permit requires a TDM plan. If TDM is applicable to your permit, staff will contact the applicant to develop a site-specific TDM plan based on the permit details. Employee ADT Estimation for Various Commercial Uses Use first 1,000 s.f. 1000 s.f.1 Office (all)2 20 13 Restaurant II 11 Retail3 8 4.5 Industrial 4 3.5 Manufacturing 4 3 Warehousing 4 1 1 Unless otherwise noted, rates estimated from ITE Trip Generation Manual, lOthEdition 2 For all office uses, use. SANDAG rate of 20 ADT/1 ,000 sf to calculate employee ADT Retail uses include shopping center, variety store, supermarket, gyms, pharmacy, etc. Other commercial uses may be subject to special consideration Sample calculations: Office: 20,450 sf 1. 20,450 sf/ 1000 x 20 = 409 Employee ADT Retail: 9,334 sf First 1,000sf=8ADT 9,334 sf - 1,000 sf = 8,334 sf (8,334 sf/1,000 x 4.5) + 8 = 46 Employee ADT Acknowledgment: I acknowledge that the plans submitted may be subject to the City of Casbad's Transportation Demand Management Ordinance. I agree to be contacted should my permit require a 1DM plan and nMtand hat an approved 1DM plan is a condifion of permit issuance. Applicant Signature._( Date: ILi )._O1.) Person other than Applicant to be contacted for TDM compliance (if applicable): Name (Panted): Phone Number: Email Address: Updated 8/15/2019 6