Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2020 CASSIA RD; ; CB071296; Permit
City of Carlsbad * 1635 Faraday Av Carlsbad CA 92008 08-312007 , Retaining Wall Permit Permit No CB071296 Building Inspection Request Line (760) 602-2725 Job Address 2020 CASSIA RD CBAD Permit Type RETAIN Status ISSUED Parcel No 2150210200 Lot# 0 Applied 05/09/2007 Valuation $1341000 Construction Type NEW Entered By MDP Reference # Plan Approved 08/31/2007 Issued 08/31/2007 Project Title 0 DAY MEDICAL OFFICE BUILDING Plan Check# TEMPORARY SOIL NAIL RETAINING WALL 745 sf Inspect Area Applicant Owner CARROLL TIM FRANZ FAMILY REVOCABLE TRUST 06 26 96 STE 100 271OLOKERAVE WEST PO BOX 2711 CARLSBAD CA 92010 RANCHO SANTA FE CA 92067 760 931 7700 Building Permit $13049 Add I Building Permit Fee $0 00 Plan Check $84 82 Add I Plan Check Fee $0 00 Strong Motion Fee $1 34 Renewal Fee $0 00 Add I Renewal Fee $0 00 Other Building Fee $0 00 Additional Fees $0 00 TOTAL PERMIT FEES $21665 Total Fees $21665 Total Payments To Date $21665 Balance Due $000 BUDDING PLANS V~~ IN STORAGE ATTACHED FINALAPPROVM Inspector _ \ \<S Date \' (, ' " 0 Clearance NOTICE Please take NOTICE that approval of your project includes the Imposition of fees dedications reservations or other exactions hereafter collectively referred to as fees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them you must follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack review set aside void or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes nor planning zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which YOU have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired PERMIT APPLICATIONi CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave Carlsbad CA 92008 FOR OFFICE USE ONLY PLAN CHECK NO EST VAL Plan Ck Deposit. Validated By. Date Address (include Bldg/Suite #)Business Name (at this address) Legal Description j Us-- Lot No Subdivision Name/Number Unit No Phase No Total # of units Assessor's Parcel #Existmg Use Proposed Use Description of Work # of Stones # of Bedrooms s of Bathrooms U State/Zip Telephone # HUferMrS! irowz^^-ia^tassiSi Name r3 Address traSorJiSDlAgeriffo^^triSi Name Address State/Zip Telephone # (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct alter improve demolish or repair any structure prior to its issuance Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom and the basis for the alleged exemption Any violation of Section 7031 5>y any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]) Name State License # S^&3*3'?& Designer Name State License # Address License Class &, < f Address City ^—^5 fl *— tf L*f /S*— »s. / I—- / j >v f C_* s City State/Zip City Business License # State/Zip Telephone # Telephone # 6 H WORKER.SCOMPENSATIONfS3i&w arisen iBKe^llEeHei! =f 4*iieto £*£ til tt&f Jfii* ..._.__ . .. _Workers Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations Q I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code for the performance of the work for which this permit is issued JJT I have and1 will maintain worker's compensation as required by Section 3700 of the labor Code for the performance of the work for which this permit is issued My worker's compensation insurance carrier and policy number are Insurance Company ()C0 /JCtPtA/BC-fC, ff&V&2/)£ /*f£vo\Kn No A Id*) S&o^O Xw*j? Expiration Date 3/11 (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) ' D CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is Issued I shall not employ any person in any manner so as to become subject tome Workers Compensation Laws of California WARNING Failure to secure workers compensation coverage Is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars($100 000) In addition to the cost of compensation damages are provided for In Section 3706 of the Labor Code interest and attorney s fees SIGNATURE_j DATE_ OH I hereby affirm that I am exempt from the Contractor's License Law for the following reason D I as owner| of the property or my employees with wages as their sole compensation will d the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If however the building or improvement is sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale) ^ I as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) ! D I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement DYES D NO 2 I (have/have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work but I have hired the following person to coordinate supervise and provide the major work (include name / address / phone number / /ontractors license number) 5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) PROPERTY OWNER SIGNATURE DATE WHITE F|(§/YELLOW Applicant PINK Finance PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave Carlsbad CA 92008 Page 2 of 2 ^SSS/Jjj^^^j^SS^&^^^^SS^^^^^^^MS:^^^Is the applicant or,future building occupant required to submit a business plan acutely hazardous materials registration for or risk management and prevention program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act? D YES 8 NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? O YES p? NO Is the facility to be constructed within 1 000 feet of the outer boundary of a school site? D YES ft NO IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS1 OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I hereby affirm that there Is a construction lending agency for the performance of the work for which this permit Is Issued (Sec 3097(1) Civil Code) LENDERS NAME LENDER S ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGEMENTS COSTS AND OSHA An OSHA permit is required for excavations of 5 0 deep and demolition or construction of structures over 3 stories in height EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authonzed by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work Is commenced for a period of 180 days (Section 106 4 4 Uniform Building Code) APPLICANT S SIGNATURE.DATE WHITE File YELLOW Applicant PINK Finance Permit# CB071296 Type RETAIN O DAY MEDICAL OFFICE BUILDING TEMPORARY SOIL NAIL RETAINING WAL Date Inspection Item Inspector Act Comments 01/03/2008 63 Walls PC Fl 09/13/200763 Walls PY NS ? 09/12/2007 63 Walls PY WC Thursday January 03 2008 Page 1 of 1 City of Caj^bad Bllpg Inspection Request For 09/13/2007 Permit* CB071296 I ^ Inspector Assignment PY Title O DAY MEDICAL OFFICENBUILDji Description TEMPORARY SOIL NAIL RETAINING WALL 745 sf Type RETAIN Sub Type Phone 8585833429 Job Address 2020 CASSIA RD Suite Lot 0 Location Inspector APPLICANT CARROLL TIM Owner FRANZ FAMILY REVOCABLE TRUST 06 26 96 Remarks A M PLEASE SOIL NAIL WALL Total Time Requested By GARRY RAGER Entered By CHRISTINE CD Description Act Comments 63 Walls Comments/Notices/Holds Associated PCRs/CVs Original PC# Inspection History Date Description Act Insp Comments 09/12/2007 63 Walls WC PY EsGii Corporation In (Partnership with government for (Building Safety DATE 6/5/O7 JURISDICTION City of Carlsbad a PLANREVIEWER a FILE PLAN CHECK NO 071296 SET II PROJECT ADDRESS 2020 Cassia Road PROJECT NAME Soil Nail Wall XI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction s building codes The plans transmitted herewith will substantially comply with the jurisdiction s building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant s copy of the check list has been sent to XI Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted /) (by ) Fax # [_l($tyJLMail Telephone^x-"" Pax Tn-Person r\\ r- XI REMARKS 1 City to approve the special inspection program 2 Keystone wall is not part of this permit /SyPlease remove sheet 19 20 21 and 22 (these sheets contain information for Keystonp wall) from City II set (at building department) By David Yaov Enclosures Esgil Corporation D GA D MB D EJ Q PC 5/29 9320 Chesapeake Drive Suite 208 + San Diego California 92123 + (858)5601468 * Fax (858) 560 1576 EsGil Corporation In Partnership with government for Quitting Safety DATE 5/14/07 OAEEUCANT /^ifj JURISDICTION City of Carlsbad ^-Q-P a FILE PLAN CHECK NO 071296 SET I PROJECT ADDRESS 2020 Cassia Road PROJECT NAME Retaining Walls The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction s building codes The plans transmitted herewith will substantially comply with the jurisdiction s building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck XI The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person XI The applicant s copy of the check list has been sent to Tim Carroll 2710LokerAve West Carlsbad CA 92010 Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Tim Carroll Telephone # 760-931-7700 Datecontacted^VO^by^^) Fax # 760-931-8680 Mail Telephone ^/Fax ,v1n Person REMARKS By David Yao Enclosures Esgil Corporation D GA D MB D EJ D PC 5/10 9320 Chesapeake Dnve Suite 208 + San Diego California 92123 + (858)560 1468 + Fax (858) 560 1576 City of Carlsbad 071296 5/14/O7 GENERAL PLAN CORRECTION LIST JURISDICTION City of Carlsbad PROJECT ADDRESS 2020 Cassia Road DATE PLAN RECEIVED BY ESGIL CORPORATION 5/10 REVIEWED BY David Yao PLAN CHECK NO 071296 DATE REVIEW COMPLETED 5/14/07 FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Uniform Building Code Uniform Plumbing Code Uniform Mechanical Code National Electrical Code and state laws regulating energy conservation noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department Engineering Department or other departments The following items listed need clarification modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3 1997 Uniform Building Code the approval of the plans does not permit the violation of any state county or city law • Please make all corrections and submit two new complete sets of prints to ESGIL CORPORATION • To facilitate recheckmg, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? Yes a No City of Carlsbad 071296 SI 14/07 1 Show on the Title Sheet all buildings structures walls etc included under this application Any portion of the project shown on the site plan that is not included with the building permit application filed should be clearly identified as ' not included on the site plan or Title Sheet The plans provided include keystone retaining wall and soil nail wall The permit application shows soil nail wall only (No keystone wall calculation provided) Please clarify Sec 10633 2 UBC Section 107 2 requires the Building Official to determine the total value of all construction work proposed under this permit Please provide the designers or contractors construction cost estimate of all work proposed 3 Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2001 editions of the California Building which adopt the 1997 UBC 4 On the cover sheet of the plans specify any items requiring special inspection in a format similar to that shown below • REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections the following checked items will also require Special Inspection in accordance with Sec 1701 of the Uniform Building Code ITEM REQUIRED? REMARKS SOILS COMPLIANCE PRIOR TO FOUNDATION INSPECTION DESIGNER-SPECIFIED OTHER 5 When special inspection is required the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit Please review Section 106 3 5 Please complete the attached form 6 Provide a copy of the project soil report prepared by a California licensed architect or civil engineer The report shall include foundation design recommendations based on the engineers findings and shall comply with UBC Section 1804 (include the recommendation for the retaining wall) 7 Specify on the foundation plan or structural specifications sheet the soil classification the soils expansion index and the design bearing capacity of the foundation Section 106 3 3 8 Provide a letter from the soils engineer confirming that the foundation plan grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soil report are properly incorporated into the plans (when required by the soil report) 9 The soils engineer recommended that he/she review the foundation excavations Note on the foundation plan that "Prior to the contractor requesting a Building Department foundation inspection the soils engineer shall advise the building official in writing that City of Carlsbad O71296 5/14/07 a) The foundation excavations comply with the intent of the soils report 10 The calculation shows the soil nail shall be located 15° from the horizontal It shall be identified on the plan 11 To speed up the review process note on this list (or a copy) where each correction item has been addressed i e plan sheet note or detail number calculation page etc 12 Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Q Yes a No 13 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive Suite 208 San Diego California 92123 telephone number of 858/560-1468 to perform the plan review for your project If you have any questions regarding these plan review items please contact David Yao at Esgil Corporation Thank you City of Carlsbad O71296 5/14/O7 City of Carlsbad Building Department BUILDING DEPARTMENT NOTICE OF REQUIREMENT FOR SPECIAL INSPECTION Do Not Remove From Plans Plan Check No O71296 Job Address or Legal Description 2020 Cassia Road Owner Address You are hereby notified that in addition to the inspection of construction provided by the Building Department an approved Registered Special Inspector is required to provide continuous inspection dunng the performance of the phases of construction indicated on the reverse side of this sheet The Registered Special Inspector shall be approved by the City of Carlsbad Building Department prior to the issuance of the building permit Special Inspectors having a current certification from the City of San Diego Los Angeles or ICBO are approved as Special Inspectors for the type of construction for which they are certified The inspections by a Special Inspector do not change the requirements for inspections by personnel of the City of Carlsbad building department The inspections by a Special Inspector are in addition to the inspections normally required by the County Building Code The Special Inspector is not authorized to inspect and approve any work other than that for which he/she is specifically assigned to inspect The Special Inspector is not authorized to accept alternate materials structural changes or any requests for plan changes The Special Inspector is required to submit written reports to the City of Carlsbad building department of all work that he/she inspected and approved The final inspection approval will not be given until all Special Inspection reports have been received and approved by the City of Carlsbad building department Please submit the names of the inspectors who will perform the special inspections on each of the items indicated on the reverse side of this sheet (over) SPECIAL INSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION 2010 + 2020 Cassia Road PLAN CHECK NUMBER. /?- QWNER- PAT O'DAY-LYNN YUT I as the owner, or agent of the owner (contractors may not employ the special inspector), certify that I, or the architect/engineer of record, will be responsible for employing the special mspector(s) as required by the Uniform Building Code (UBC) Section 17011 for the construction project located at the site listed above UBC Section 10635 Signed I, as the architect/^ngineer of recbrd, certify that I inspection program as required by UBC Section located at the site __J^_ ?3 Architect9 / Engi^^P^Csfl^^^jre required have prepared the following special 106 3 5 for/the construction project Signed 1 List of work re D Sods Compliance Prior to F3t&filanon Inspection D Structural Concrete over 2500 PSI D Prestressed Concrete D Structural Masonry D Designer Specified D D D D Field Welding High Strength Bolting Expansion/Epoxy Anchors Sprayed On Fireproofing Others Soil Nail Shoring 2 Name(s) of indmdual(s) or firrn(s) responsible for the special inspection listed above A. By Owner •» <*Q>tXTH.&tA) B C 3 Duties of the special inspectors for the work listed above A. Placement & Testing of Shotcrete Placement of Rebar B Drilling holes + Illustration of Soil Nail Soil NaiTTesting C Verification that Soil/ Rock encountered is consistent w/ findings of the GeothectmcalInvestigation. Special Inspectors shall cheek in with the City and omen! the r credentials for approvalrp ]ol Ltp beginning work on the lob site City of Carlsbad O71296 5/14/07 VALUATION AND PLAN CHECK FEE JURISDICTION City of Carlsbad PLAN CHECK NO O71296 PREPARED BY David Yao DATE 5/14/07 BUILDING ADDRESS 2O2O Cassia Road BUILDING OCCUPANCY TYPE OF CONSTRUCTION BUILDING PORTION retaining walls Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) 745 cb RIHn Pprmif FPP hv Orrlmanrp ^ Valuation Multiplier 1774 By Ordinance Reg Mod VALUE ($) 13216 13,216 $13049 Plan Check Fee by Ordinance Type of Review f~l Repetitive FeeRepeats Complete Review D Other r—I Hourly Structural Only Hour* Esgil Plan Review Fee Comments $8482 $7307 Sheet 1 of 1macvalue doc City of Carlsbad O71296 5/14/O7 VALUATION AND PLAN CHECK FEE(Revised 6/5/07 dy) JURISDICTION City of Carlsbad PREPARED BY David Yao BUILDING ADDRESS 202O Cassia Road PLAN CHECK NO O71296 DATE 5/14/07 BUILDING OCCUPANCY TYPE OF CONSTRUCTION BUILDING PORTION retaining walls Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) 745 cb Valuation Multiplier 1774 By Ordinance Reg Mod VALUE ($) 13216 $72,222 13 216 $433 61 CM "an /ioip 1 OU 'I a Plan Check Fee by Ordinance Type of Review I I Repetitive FeeRepeats Complete Review D Other i—i Hourly Structural Only Hour Esgil Plan Review Fee CQ/I QOl|JU • \Jt— $242 82 $73 f)7\+/l\J \J I Comments This permit is for soil nail wall only The valuation for the soil nail wall is $72 222 per Pacific Building group Sheet 1 of 1 macvalue doc City of Carlsbad Public Works — Engineering BUILDING PLANCHECK CHECKLIST RETAINING WALL BUILDING PLANCHECK NUMBER CB BUILDING ADDRESS PROJECT DESCRIPTION Retaining Wall ASSESSOR S PARCEL NUMBER £fS ~ ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved The approval is based on plans information and/or specifications provided in your submittal therefore any changes to these items after this date including field modifications must be reviewed by this office to insure continued conformance with applicable codes Please review carefully all comments attached asfailure to comply with instructions in this report can in sustansrep of permit to, build DateBy' DENIAL Please see {he attached report of deficiencies marked with JK; Make necessary corrections to plans or /specifications for compliance with applicable codekand standards Submit corrected plans and/or specifications to this office for review Date 5/f/f)~ ATTACHMENTS Right of Way Permit Application ENGINEERING DEPT CONTACT PERSON NAME JOANNE JUCHNIEWICZ City of Carlsbad ADDRESS 1635 Faraday Avenue Carlsbad CA 92008 PHONE (760) 602 2775 H VWQRPVDOCSVf^HKI n Wall RiHlrllnn PlanrhoHt P.Hcl Fm 1635 Faraday Avenue • Carlsbad CA 92OO8 7314 • (760) 6O2 272O • FAX (76O) 602 8562 BUILDING PLANCHECK CHECKLIST RETAINING WALLS siv Q Q 3RD/ Q 1 Provide a fully dimensioned site plan drawn to scale Show A North Arrow B Existing & Proposed Structures (dimensioned from street) C Property Lines Show on site plan A Drainage Patterns B Existing & Proposed Slopes C Existing Topography 3 Include on title sheet /A Site Address B Assessor s Parcel Number C Legal Description D Grading Quantities Cut D Easements E Retaining Wall (location and height) do Fill Import/Export (Grading Permit and Haul Route Permit may be required) Project does not comply with the following Engineering Conditions of approval for Project No _ Conditions were complied with by Date MISCELLANEOUS PERMITS 5 A RIGHT OF WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way A separate Right-of Way issued by the Engineering Department is required for the following Please obtain an application for Right-of-Way permit from the Engineering Department Pagel \\LASPAI MAS\SYSU.IBRARY\ENG\WORD\DOCS\CHKLST\Raa Dfl W II Bulk) ng Planctieck Cktet Form JJ doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER 01 DATE ADDRESS RESIDENTIAL TENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR PLAZA CAMINO REAL (<$10,000.00) CARLSBAD COMPANY STORES POOL / SPA RETAINING WALL VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER DATE ENGINEER DATE J \D\070000 AAAA\070100-Cassia\Calcs\04-03-07\Cover-Sheet 4/3/2007 5 02 PM INC Structural Engineers 124 GREENFIELD AVENUE SAN ANSELMO CA 94960 Tel (415)259-0191 Fax (415)259-0194 www pbandainc com ENGINEERING CALCULATIONS TEMPORARY EARTH RETENTION SYSTEM O'DAY MEDICAL OFFICE BUIDLING 2020 CASSIA ROAD CARLSBAD, CA FOR . . CONDON - JOHNSON "; & ASSOCIATES lit _ COHTHACTORS AND EN3INEEHS JOB NO 070100 MARCH 03 2007 124 Greenfield Avenue CA 94960 TEL 415 259-0191 FAX 415 259-0194 e mail pba@pbandainc com PIROOZ BARAR 8, ASSOCIATES Index Page 1 4/3/2007 5 07 PM Pirooz Barar & Associates Structural Engineering JOB NO 70100 FOR Condon-Johnson Associates Inc DESCRIPTION TEMPORARY EARTH RETENTION SYSTEM LOCATION Carlsbad CA Date 3 Apr 07 Page i CONTENTS PAGE 0) INDEX i 1) Punch Shear Calculation 1 thru 3 II) Design of 17 ft High Wall w/ 4 rows of Soil Nails 4 thru 7 124greenfield Ave San Anselmo CA 94960 P (415)259-0191 F (415)259-0194 pba@pbandamc com PB&A INC Soil Nail Temporary Only mcd 1/3 4 49 PM 4/3/2007 ^. J= = FOR Structural EngineeringFOR Condon JohnSOn ASSOCiateS JOB Cassia Street JOB NO 070100 JLiprSocon! )"9'94 DESCRIPTION Punch Shear Calculation Pba®Pbandaino °°m REFERENCE CALTRANS TRENCHING AND SHORING MANUAL LOCATION Carlsbad CA DATE 04/03/07 Input Parameters Sh = 6 0 ft Sy = 6 0 ft fc = 4000 psi F = 65 ksi fy = 60 ksi h. = 4 in Tot = 25kip L =4 + — in VERIFICATION OF FACING CONNECTIONS (HORIZONTAL SPACING OF SOIL NAILS) (VERTICAL SPACING OF SOIL NAILS) (COMPRESSIVE STRENGTH OF SHOTCRETE) (YIELD STRESS OFWWF) CONDON JOHNSON CONTRACTORS AND ENGINEERS PAGE = 1 Units Conversion kip = 1000 Ibf psi = 1 Ibf in/VW1A ksi = 1000 psi psf = 1 Ibf ft-2 = 0 625 in (YIELD STRESS OF REINFORCING IN TEMPORARY FACING) (THICKNESS OF TEMPORARY FACING) (DESIGN OF NAIL HEAD TENSILE FORCE OF TEMPORARY FACING) (HEADED STUD LENGTH, 5/8"x6 9/16 STUD) (HEADED STUD HEAD THICKNESS, 5/8 x6 9/16' STUD) pcf = 1 Ibf ft NA =0 -3 A Facing Flexural Capacity Calculate required plate area Lbp=423m Choose Lbp = 8 in (BEARING PLATE LENGTH) Calculate required plate thickness lot P L 2Lbp f = 390 63 psi 1washer = 3 in Lbp ^washer Actual beanng pressure Diameter of beveled washer DISTANCE FROM EDGE OF WASHER TO EDGE OF PLATE (T)415 259 0191 (F)415 259 0194 124 Greenfield Ave San Ansel mo CA e mail pba@pbandainc com PB&A INC Soil Nail Temporary Only mcd 2/3 4 49 PM 4/3/2007 PAGE = 2 Required thickness tbp = 039m Choose tb =075 in (BEARING PLATE THICKNESS) USE 8 x8 x3/4 PLATE B Facing Flexural Capacity Temporary Facing CF = 2 Factor due to non uniform soil pressure USE 4x4xW29xW29 WWF WALER BARS = 2 0 31 in2 arb = (EFFECTIVE TOTAL CROSS SECTIONAL AREA OF WALER BARS ) (EFFECTIVE UNIT CROSS SECTIONAL AREA OF REBARS) = a^K + 0 087 — (UNIT CROSS SECTIONAL AREA OF WWF) 0 in2 fy ft FT, inarb avm ft awb ahm ahn = ahm awb shhtRFF1=38CF(avm+avn)—^ R Q -I .FF2=38CF(ahm+ahn)-^Fy RFF1 = 45 67 kip RFF2 = 4567kip RFF == min(RFF1 FSFF = 135 Rreq ~ FSFF Tot Safety factor against facing flexural failure 4^Q &• *&*$&>& «^ Rreq < RFF OK (T)415 259 0191 (F)415 259 0194 124 Greenfield Ave San Anselmo CA e mail pba@pbandamc com PB&A INC Soil Nail Temporary Only mcd 3/3 4 49 PM 4/3/2007 PAGE = 3 Pmt = pnt - 0 5 h 0 5 h p_t = 0 793mt pnt = 0 793nt Limit Reinforcement in Facing 024 psi mm ksi ksi 90 90 + — Pmax = ksij It can be noted that all the reinforcement density is within the limit Pnt =0793 C Punching Shear Capacity Temporary Facing Shs=Lbp-215in hc=Ls"th . = min(2 hc hc + S = 9 38m h =469m Temporary Density Headed stud spacing Effectve depth of conical surface Effective diameter of conical failure surface at the center ft'2 -yj psi r Spp — 1 35 Rreq = FSFP Tot OK Safety factor against facing punching shear (T)415 259 0191 (F)415 259 0194 124 Greenfield Ave San Ansel mo CA e mail pba@pbandamc com Pirooz Barar & Associates Structural Engineering Calculations [input and Output for Winslope Analysis Excavation Profile JOB NO FOR DESCRIPTION LOCATION 70100 CJA TEMPORARY Soil Nail CASSIA PROFESSIONAL OFFICES Date Page 3 Apr-07 t El TOSL =+303 5 X 00 00 120 130 1000 Y 00 170 290 300 300 El TOW =+2915 El BOW =+274 5 'U Temporary Soil Mail Static Analysis Wall Heights 17Oft Soil Strata Profile Soil Profile Silty Sand X 00 1000 Y 100 100 Phereatic Water Surface X N/A Y tel (415)259-0191 fax (415)259-0194 124 Greenfield Ave San Anselmo CA 94960 email pbarar@pbandamc com website www pbandamc com Pirooz Barar & Associates Structural Engineering JOB NO FOR DESCRIPTION LOCATION 70100 CJA Date Date Page 3 Apr 07 TEMPORARY Soil Nail CASSIA PROFESSIONAL OFFICES Soil Properties Soil Prop Silty Sand Weight of Soil 7 Unsat (PCF) 135 Sat (PCF) 135 Static I Dynamic C(PSF) 200 q> 35 M (PSF) 1500 C(PSF) 200 <P 35 U- (PSF) 1500 Surcharge qu (psf) 200 Sx, (ft) | 12 | Sx2 (ft) 100 (PSF) = Pullout Strength C = Cohesion q> = Friction Angle •SOIL LAYER BOUNDRY NAILS PHREATIC WATER SURFACE SOIL LAYER N2 [SOIL LAYER~2] / BOUNDRY WEDGE 2 JSOIL LAYER 5| tel (415)259-0191 fax (415)259-0194 124 Greenfield Ave San Anselmo CA 94960 email pbarar@pbandamc com website www pbandainc com Pirooz Barar & Associates Structural Engineering Nail Geometry & Properties JOB NO FOR DESCRIPTION LOCATION 70100 CJA TEMPORARY Soil Nail CASSIA PROFESSIONAL OFFICES Date Page 3 Apr 07 Row# 1 2 3 4 Y(ft) 20 65 110 155 L(ft) 150 150 200 250 d(m) 60 60 60 60 S(ft) 60 60 60 60 6(deg) 150 150 150 150 As(m2) 078 078 078 078 Fy(ksi) 750 750 750 750 Row# 1 2 3 4 Perm Pu (k.p) 25 25 25 25 Temp Pu (kip) 25 25 25 25 Prestr ing (kip) 0 0 0 0 M Multiplier 1 1 1 1 Pu = Punching Shear Fy = Yield Stress of Steel \fj. = Pull-out Strength S = Hole Spacing As= Area of Steel tel (415)259-0191 fax (415)259-0194 124 Greenfield Ave San Anselmo CA 94960 email pbarar@pbandamc com website www pbandamc com Pirooz Barar & Associates Structural Engineering JOB NO FOR DESCRIPTION LOCATION 70100 CJA TEMPORARY Soil Nail CASSIA PROFESSIONAL OFFICES Date Page 3 Apr 07 Results from Static Analysis Intermediate Data Wedge # 1 2 Sat Wt (Ib) 27540 15238 Bo Wt (Ib) 27540 15238 Dry Wt (Ib) 27540 l_ 15238 <P 450 563 Avg Soil Prop Under Wedge 1 Under Wedge 2 On Vert Plane C(PSF) 2000 1889 2000 H(PSF) 15000 14167 15000 fl> 350 335 350 Coordinate of Failure Plane A B C X 00 120 240 Y 00 120 300 Detailed forces in the nails Row# 1 2 3 4 Xmt 16 5 1 87 122 Ymt 16 51 87 122 Wedge mt 1 1 1 2 Fleft (Ib) 48847 6 57504 9 66162 1 74664 4 F right (Ib) 31495 3 22838 1 25961 8 29240 4 F yield (Ib) 58500 0 58500 0 58500 0 58500 0 F Crtl (kip) 315 228 260 292 Ctrl Factor Pullout Pullout Pullout Pullout FOS =1 35 (Temporary-Static) tel (415)259-0191 fax (415)259-0194 124 Greenfield Ave San Anselmo CA 94960 email pbarar@pbandamc com website www pbandainc com I I I < SOIL & TESTING INC San Diego Office Indio Office cc O 3 e O May 17 2007' PHONE(619) 280 4321 TOLL FREE(877) 215 4321 FAX (619) 280 4717 PO Box 600627 San Diego CA 92160 0627 6280 Riverdale Street San Diego CA 92120 www scst com PHONE (760) 775 5983 TOLL FREE (877) 215 4321 FAX ~* (760) 775 8362 83 740 Citrus Avenue Suite G Indio CA 92201 3438 www scst com SCS&TNo 0611114 61 •1 1 1 • 1 •1 1 •1 1^B 1 |w Mr Pat O Day O Day Consultants < 271 0 Loker Avenue West Suite 1 00 Carlsbad California 92010 \ Subject RESPONSE TO CITY OF CARLSBAD COMMENTS O DAY MEDICAL OFFICE BUILDING 2020 CASSIA ROAD CARLSBAD CALIFORNIA I Dear Mr ODay v This letter has been prepared to respond to the comments prepared by the • **fmr^r* » i w^* w f EsGil Corporation Plan Checker for the City of Carlsbad The city comments and responses are presented below Comment 6 Provide a copy of the project soil report prepared by a California licensed architect or civil engineer / The report shall include foundation design recommendations based on the shall comply with UBC Section 1804 (include the recommendation for the re Response 6 ' engineers findings and - taming wall) " / ^Copies of the project soil reports applicable to the subject project (References 3 and 4) are provided /_^. in Appendix I and II Comment 8 i Provide a letter from the soils engineer confirming that the foundation specifications have been reviewed and that it has been determined that the soil report are properly incorporated into the plans(when required by the soil Response 8 J (^)plan grading plan and recommendations in the report) The plans References 2 and 3 have been reviewed and were found to be in accordance with the recommendations provided in the referenced reports Additionally slope fj* "u med The site wil! have a fac*c> ot safety g cater than 1 5 in respect completion oHhe project ShotftdY^uha^anyauestions regarding this document please contact me /Respectfully submittecl \\ SO^ERN CALIFORNIA SOIL & TESTING, INC II cC \ *>^*P 9 ..gn onifjo^ / f~n n .-- ^s^ (~-^'G^^^^^JEowpfeTOfG.fc 2752 f ~ Seffio^^r^f^^;^ \ (6) Addressee Attn Tim Carroll GBF kv / Attachments N\ Appendix I f Appendix II / stability analyses were to global stabiLy a \ c \ at (61 9) 280 4321 1 f • ^^ .^*^^^ » ^^^ 1f 10 r\^7 i^~~) fji /F-^S / i / ; / ^7 > — ^ I I ( O Day Consu/fanfs May 17 2007 O Day Medical Office Building SCS& TNo 06111146 2020 Cassia Rd Carlsbad CA Page 2 I I I I I I I I I I I REFERENCES 1 ) Keystone Retaining Wall Plans For Cassia Professional Offices All Cats Hospital Keystone Retaining Wall Plans Sheets J to 5 prepared by Red One Engineering • dated December 21 '2006 2) Temporary Shoring Wall (Adjunct to Keystone RW) For Cassia Professional Offices Plans • Sheets 23 to 25 prepared by PB&A dated April 30 2007 3) Shoring Recommendations Cassia Professional Offices 2020 Cassia Road Carlsbad • California prepared by Southern California Soil and Testing dated February 26 2007 (SCS&T Job Number 0611114 5) 1 4) Preliminary Retaining Wall Design Recommendations All Cats Hospital Testing Services El Cammo Real and Cassia Road Carlsbad California prepared by Southern California Soil and Testing Inc dated September 8 2006 (SCS&T No 06111152) 5) City Comments prepared by EsGil Corporation Plan Check Number 071296 dated May 14 2007 APPENDIX I 4 SOU ft TCSTINQ INC Z O I I I I I I I I I I I I O Z O f H O N f (633) 280 43"1] I O L I f R L £ (877) 215 4.521 F A X (619) ?80 4/17 San Diego Office PO Box f0062/ San Diego CA 92160 062/ i 280 Ri/c rdil< Sttct I Sin Diepo CA 92120 www scst com H N f(7CO;77S 'OIL f P I I (8^ ?]5 3^ Septembers 2006 Ms Lynn Yut All Cats Hospital 7O40 Loker Avenue West Suite 100 Carlsbad California 92008 Indio Office 8-, 710 uitius \v( r Ul <=u ( C I du CA 2/01 -,4j8 8362 ^^w sc com SCS&TNo 0611115 Report No 2 Subject Reference Dear Ms Yut PRELIMINARY RETAINING WALL DESIGN RECOMMENDATIONS ALL CATS HOSPITAL TESTING SERVICES EL CAMINO REAL & CASSIA ROAD CARLSBAD CALIFORNIA Geotechnical Investigation Cassia Road Project* prepared by Geocon Incorporated dated December 16 2004 (Project No 07431 2201) In accordance with a request from Mr Tom Guinn Southern California Soil and Testing Inc has prepared this report to provide preliminary retaining wall design recommendations for the masonry retaining walls for the subject project FOUNDATIONS Conventional shallow foundations may be utilized for the support of the proposed retaining walls The footings should have a minimum depth of 18 inches below lowest adjacent finish pad grade and a minimum width of 12 inches A bearing capacity of 3000 pounds per square foot (psf) may be assumed for said footings The bearing capacity may be increased by 300 psf and 500 psf for each additional foot of foundation width and depth respectively up to a maximum of 5000 psf The bearing capacity may be increased by one third when considering wind and/or seismic forces Footings located adjacent or within slopes should be extended to a depth such that a minimum horizontal distance of 10 feet exists between the outer footing edge and the face of the slope EARTH RETAINING WALLS Passive Pressure The passive pressure for the prevailing soil conditions may be considered to be 300 psf per foot of depth This pressure may be increased by 1/3 for seismic loading The coefficient of friction between concrete and the underlying material may be assumed to be 0 30 When combining fnctional and passive resistance friction should be reduced by 1A The upper 12 inches of soil should not be considered when calculating passive pressures for exterior walls I I I I I I I I I I I I I I I I I I I Ms Lynn Yut September 8 2006 All Cat s Hospital SCS& TNo 06111152 El Camino Real and Cassia St Carlsbad, CA Page 2 Active Pressure The active soil pressure for the design of unrestrained earth retaining structures with level backfills may be assumed to be equivalent to the pressure of a fluid weighing 40 pounds per cubic foot (pcf) This pressure does not consider any surcharge loads If any are anticipated this office should be contacted for the necessary increase in soil pressure These values assume a granular and drained backfill condition Waterproofing specifications and details should be provided by the project architect A typical wall subdram detail is provided on Plate No 1 Waterproofing and Subdrain Observation The geotechnical engineer should be requested to verify that waterproofing has been applied and that the subdram has been properly installed However unless specifically asked to do so, we will not verify proper application of the waterproofing Backfill All backfill soils should be compacted to at least 90 percent relative compaction Expansive or clayey soils should not be used for backfill material The wall should not be backfilled until the grout has reached an adequate strength Should you have any questions regarding this document or if we may be of further service please contact our office at your convenience \/ery truly yours ^ JNIA SOIL & TESTING, INC DBAkv (2) Addressee (2) O'Day Consultants Inc (1) Geognd Retaining Wall Systems Inc Attn Forrest Armentrout (fax also) ATTACHMENT Plate No 1 5,0 §T Typical Retaining Wall Subdram Detail Not to Scale 18 miri CompactedFill Miradrain 6000 or equivalent 2 3 wall height (T) Floor Slab (5) Filter Fabric between rock and soil @ Backcut (7) Waterproof back of wall following architect s specifications (5) 4 minimum perforated pipe SDR35 or equivalent holes down 1 % fall to outlet top of pipe below top of slab encased in 3/4 crushed rock Provide 3 cubic feet per linear foot crushed rock minimum Crushed rock to be surrounded by filter fabric (Mirafi 140N or equivalent) with 6 minimum overlap Provide solid outlet pipe at suitable location %<L SOUTHERN CALIFORNIA 1 9"V SOIL & TESTING, INC ALL CATS HOSPITAL BY JOB NUMBER DBA 06111152 DATE PLATE NO 9/8/2006 1 APPENDIX II I I I I I I I I I I I I I I I I I I I J SOIL * TISTINO INC Z 3 ovt PHONE (619) 280 4321 TOLL F R r L (877)21r 4321 FAX (619)280 4717 San Diego Office PO Box 600627 San Dipgo CA 92160 0627 f ?HO Rivfidale btixet Sin Diego CA 92120 www scst com PHONE (/60) 775 ^983 TOLL PRLE (877)215 4321 FAX (760) 775 8362 Indio Office 83 740 Citrus Avenur Suite G Indio CA 92201 3438 www cst com February 26 2007 SCS&TNo 0611114 Report No 5 Mr Pat O Day O Day Consultants 2710 Loker Avenue West Carlsbad, California 92008 Subject SHORING RECOMMENDATIONS O'DAY MEDICAL OFFICE BUILDING 2020 CASSIA ROAD CARLSBAD CALIFORNIA Reference Keystone Retaining Wall Plans For Cassia Professional Offices All Cats Hospital Keystone Retaining Wall Plans Sheets 1 to 5" prepared by Southern California Soil and Testing Inc dated December 21 2006 Dear Mr O'Day In accordance with a request from Mr Erik Nelson of Pacific Building Group this letter has been prepared to provide shoring recommendations for the subject project We understand improvements will consist of a road widening supported by a Keystone wall and a curb inlet structure The site is underlain by undocumented fill and formational material commonly identified as the Santiago Formation To determine the extent of the fill along the planned wall alignment SCS&T drilled 3 borings at the locations indicated on Figure 1 The fill was determined to range from approximately 10 to 25 feet in depth thickening to the south and east The fill consists of soft clays and loose clayey sands The boring logs are presented in Appendix I Laboratory testing performed on the sample is presented in Appendix II Shoring along El Camino Real will be required to support excavations for the construction of the planned wall and curb inlet structure It is anticipated that soldier beams with tiebacks and lagging will be utilized ranging from about 15 to 27 feet in height starting at wall Station 2+80 and ending at Station 4+00 Areas north and south of the shored area can be cut temporarily at an inclination of 1(H) 1(V) with a 5 foot vertical at the toe of the slope Cross section A A', Figure 2, shows the anticipated top and bottom elevation of the shoring along El Camino Real Typical sections through the most critical areas are shown on Figures 3 and 4 The design parameters to calculate the earth pressures on shoring are presented in Table 1 1 1 •1 1 1 • 1^w 1 1 • 1•1 1 1 • 1 1 O Day Consultants February 26 2007 O Day Medical Office Building SCS&T No 06111145 2020 Cassia Rd Carlsbad CA Page 2 Table 1 Total Unit Weight intornai frMln Cohesion Value Material Pounds Per Cubic Angle- Phi Pounds per Square Fill 125 27 100 Formation 135 35 500 An active condition can be applied to shoring that is capable of rotating 0 002 radians An at rest condition should be applied to a shoring system that is unyielding and not able to rotate Construction surcharge loads should be evaluated on a case by case basis Soils should no be stockpiled at the top of slopes or at the top of the shoring Vertical and lateral movements of the temporary shoring are expected to be small assuming an adequate lateral support system If any other surcharge loads are anticipated SCS&T should be contacted for the necessary increase in soil pressure The passive pressure for the design of the proposed shoring system may be considered to be 350 psf per foot of depth up to a maximum of 5 000 psf The passive pressure may be assumed to act on an area equal to twice the soldier beam diameter This value may be increased by 1/3 for seismic loading The upper 1 foot of embedment should be neglected when calculating passive pressures Survey monuments should be installed at no more than 40 foot intervals along the perimeter of the excavation One row of monuments should be located just beyond the edge of the top of excavation A second row should be established 10 feet beyond the excavation, and a third row should be set 20 feet from the top of the excavation A reference point should be established well away from the block where the excavation will take place The horizontal and vertical location of each monument should be established with a survey instrument before excavation starts Readings should be made daily during the initial stages of excavation say for up to one week Results of the initial readings will be reviewed by SCS&T and modifications to the monitoring schedule may be made depending on these results Significant sloughing and erosion of the slopes should be anticipated In addition construction activities above or near the slopes could affect overall stability The slopes should be observed by a representative of SCS&T periodically to ascertain that no unforeseen adverse conditions are observed The temporary slopes should be inspected daily by the contractor s Competent Person before personnel are allowed to enter the excavation Zones of potential instability sloughing or raveling should be brought to the attention of the Engineer and corrective action si 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 O Day Consultants February 26 2007 O Day Medical Office Building SCS& TNo 06111145 2020 Cassia Rd Carlsbad CA Page 3 implemented before personnel begin working in the trench No surcharge loads should placed within a distance from the top of temporary cut slopes equal to half the slope height This opportunity to be of professional service is sincerely appreciated /""" -•- Respectfully submitted, // / SOUTHERN CALIFORNIA SOIL & TESTING, INC , / \ Daniel B t AdJ^I" $%teC$ J /Ga^Bi ,1= puntairv, GE 2752 Vice President / */J Senio^Engineel1 :/ DBAkv ^ J ^"^/ (4) Addressee (1) Pacific Building Group Attn Erik Nelson via email Erik ©pacificbuildmggroup com (1) Anderson Drilling Attn Mike Empizo via email - mempizo@andersondnlling com Attachments Figures 1234 Appendix I Appendix II be 5Mi5 CD i i i i i i i i i i i i i i i i ii i i i i i i i i i i i i i o>COm 10 -> O OI co m rn o» .j 01 01 « N)^1cn 00oI Nicocn CDOI NiCO COOO COOcn_L o oI I I I I II I I I I I cno CO cn01 1 1 1 1 1 1 1 - t ^M0 o 0611114-5•n (Qc ^ CD GF/DCDDfl) (D to fy) O O d -< mo o r~ CD F D G> *^M/f^ \f«fo ^ 7 SOUTHESOIL&TW P^r C/) ^ I-} P C ^"H3 oPJi— i M N3 N) NJ N3 CO CO^J 00 CO CD CO O Ocn o cn o cn o cn \) </) a> 1 0 £? £(B Q> 3- 5" rn Q (0(00] 0 O ~ O -n =1o o 1 1- oD APPENDIX I sr SUBSURFACE EXPLORATION LEGEND UNintDSOILC 1 ASSIHCAIIONUIARI SOIL m sc RU UON SYMBOL ' Yl 'iAy^Mfe^ 1 COAKSL C KAINK1) more than half of material \% larger than No OKAVtUs CtrANGRAVHS C W Mor 111 in half ol coarse Iraction is larger than No 4 ( P icve si/e but smaller lhan 3 ( RAVH S Will) HNrS < M ( Appreciable amount ol lines) ( C SANDS. CLEAN SANDS SW More than h lit ol cotrse fraction is smaller lhan No 4 SP icve size SANDS Wl III HNLS SM (Appreciable amount ot tines) SC 200 sieve size Well grided gravels gravel sand mixtures little or no lines P > irly graded gravels gravel sand mixtuies little or n > lines Silly gravels poorly graded gravel sand silt mixtures C laycy gravels poorly traded gravel sand clay mixtures W II gr ided ind gravelly imds little or no lines Poorly graded sands gravelly sands little or no fines Silty sands poorly grided sand and billy mixtures C laycy sands poorly traded sand ind clay mixtures II UNI- ( KAINPI) more than half of material Is smaller than No 200 sieve sl/e SILTS AND CLAYS ML In >r(_,anic silts and very line sands rock Hour sandy sill I iquid Lunil less than 50 r clayey sill sand mixtures with slight plasticity CL Inorganic clays ot low to medium plasticity gravelly clays sandy clays silty clays lean clays OL Organic silts and organic silty clays or low plasticity SILTS AND CLAYS MH I iquid Limit greater than SO CM OH III HIGHLY ORGANIC SOILS PT ^ Water level at time of excavation or as indii atcd US Undisturbed driven ring sample or tube sample SC Sand Cone CON Consolidation El Expansion Index MS Maximum Size of Particle MAX Maximum Density ST Shelby Tube SPT Standard Penetration Sample pH pH & Resistivity SF/CL Sullate & Chloride Inorganic silts micaceous or diatomaccous line sandy or silty soils elastic silts Inorganic clays of high plasticity fit clays Organic clays ot medium to hijji plasticity Peat and other highly organic soils C K Undisturbed chunk sample ffl Bulk Sample DS Direct Shear SA Sieve Analysis PI Plasticity Index RC Relative Compaction UC Unconfined Compression TX fnaxial Compression RS Ring Shear AL Atterberg Limits RV R Value Cl SOUTHERN CALIFORNIA ODAY MEDICAL OFFICE BUILDING ROAD WIDENING i IT? SOIL & TESTING, INC BY ^^\^ JOB NUMBER DBA DATE 2/26/2007 0611114 APPENDIX I 11 LOG OF EXPLORATORY BORING NUMBER B-1 Date Excavated 2/16/2007 Logged by MM Equipment CME 55 Project Manager GBF Surface Elevation (ft) 303 Depth to Water (ft) N/A g £ID Q - 2 - 6 - 8 - 10 - 12 - 14 -16 - 18 - 90 CO O COD SM CL SC CL SUMMARY OF SUBSURFACE CONDITIONS ASPHALT 6 Inches FILL(Qaf) Brown moist dense SILTYSAND ASPHALT 3 inches FILL(Qaf) Brown to gray moist soft SILTYCLAY FILL(Qaf) Light brown moist loose to medium dense CLAYEY SAND FILL(Qaf) Dark brown moist soft SANDY CLAY *SC. SOUTHERN CALIFORNIA I $10 SOIL & TESTING, INC Vw^N*. SAMPLES I UNDISTURBEDus us us n: 03 X IPENETRATION(blows/ ft ofdnve)j 19 15 MOISTURE (%)— I H Z 3 £Q LABORATORY TESTS-- ODAY MEDICAL OFFICE BUILDING ROAD WIDENING BY AP/GBF JOB NUMBER 0611114 DATE 2/26/2007 APPENDIX I I 2 LOG OF EXPLORATORY BORING NUMBER B-1 (continued) Date Excavated 2/17/2007 Equipment CME 55 Surface Elevation (ft) 303 g £UJa -22 -24 - 26 - 28 -30 - 32 - 34 - 36 - 38 - 40 coO CO Z3 SM SM \ Logged by MM Project Manager GBF Depth to Water (ft) N/A SUMMARY OF SUBSURFACE CONDITIONS FILL(Qaf) Ligth brown to tan moist dense SILTY SAND SANTIAGO FORMATION(Ts) SILTY SAND Light brown moist very dense PRACTICAL REFUSAL @ 26 FEET j£7^ SOUTHERN CALIFORNIA ( S*& S°IL & TESTING< INC SAMPLES UNDISTURBEDus x :D CO PENETRATION(blows/ ft ofdnve)53 MOISTURE (%)1 h- zD ocQ LABORATORY TESTS0 DAY MEDICAL OFFICE BUILDING ROAD WIDENING BY AP/GF JOB NUMBER 0611114 DATE 2/27/2007 APPENDIX I I 3 LOG OF EXPLORATORY BORING NUMBER B-2 Date Excavated 2/16/2007 Equipment CME 55 Surface Elevation (ft) 303 4±, X Q.UJ Q - 2 - 4 - 6 - 8 -10 , -12 - 14 -16 -18 COo CO SM CL ML SM Logged by MM Project Manager GBF Depth to Water (ft) N/A SUMMARY OF SUBSURFACE CONDITIONS ASPHALT 6 Inches FILL(Qaf) Brown moist dense SILTYSAND FILL(Qaf) Brown to gray moist soft CLAY FILL(Qaf) Light brown to tan moist stiff SANDY SILT SANTIAGO FORMATION(Ts) SILTY SAND Light brown moist very dense REFUSAL @ 17 FEET SAMPLE Q DISTURBSZ us us us EC -» "3"NETRATIOfvs/ft ofdnvUJ o °~ fi. 12 25 71 -r-ISTURE (°xO2 c-ua. Z £O COUJ (RATORYu -1 s^l SOUTHERN CALIFORNIA i STL? SOIL & TESTING, INCx^V. ODAY MEDICAL OFFICE BUILDING ROAD WIDENING BY AP/GBF JOB NUMBER 0611114 DATE 2/26/2007 APPENDIX I I-4 LOG OF EXPLORATORY BORING NUMBER B-3 Date Excavated 2/16/2007 Equipment CME 55 Surface Elevation (ft) 303 „-> £.DEPTH- 2 - 4 - 6 - 8 _ in~ IU - 12 - 14 L- 16 - 18 on O D SW CL SM Logged by MM Project Manager GBF Depth to Water (ft) N/A SUMMARY OF SUBSURFACE CONDITIONS ASPHALT 6 Inches FILL(Qaf) Brown moist dense WELL GRADED SAND FILL(Qaf) Brown to gray moist soft SILTYCLAY SANTIAGO FORMATION(Ts) - SILTY SAND Light brown moist very dense SIL REFUSAL® 15 FEET SC, SOUTHERN CALIFORNIA i § T^ SOIL & TESTING, INC SAMPLE Otu CO<£.ID CO Qzo a. yUSA us F- z ?0 c i!Muj §a e 17 73 i?ISTUREO2 c-uQ. , f-z Q (/> COLU >)RATORu CQ 3 ODAY MEDICAL OFFICE BUILDING ROAD WIDENING BY AP/GBF JOB NUMBER 0611114 DATE 2/26/2007 APPENDIX I I 5 APPENDIX II scit 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 s/ 50 45 40 3S C- 30 g 3 I " CO 20 1 5 10 05 00 0 Direct Shear Test Results • Shea inche r Strength s of Defoi ^ - at 02 mation i * i r * - ^ I • _ I 0 OS 10 15 20 25 30 35 40 Confining Pressure (ksf) i - 45 50 INTERNAL COHESION FRICTION INTERCEPT VMPLE DESCRIPTION ANGLE(DEG ) (PSF) B2@6-6 5 Shear Strength at Tan Clayey Sand 27 98 0 2 Inches of Deformation SO- SOUTHERN CALIFORNIA (jS^nS/ SOIL & TESTING O DAY MEDICAL OFFICE BY JJS/GBF JOB NUMBER 0611114 DATE 2/27/2007 APPENDIX II 1 I I I I I I I I I I I I I I I I I I I s/ 50 45 40 35 Cf 30 S 2s to 1 to 20 15 10 05 00 0 Direct Shear Test Results — — , ^ • Shea inche • „ * r Strength s of Defor t p ' at 02 mation : * * • * \ I r 0 05 10 15 20 25 30 35 40 Confining Pressure (ksf) | - 45 50 INTERNAL COHESION FRICTION INTERCEPT WPLE DESCRIPTION ANGLE(DEG ) (PSF) Shear Strength at Brown Clay 33 333 0 2 inches of Deformation S O,. SOUTHERN CALIFORNIA (. S*rJ SOIL & TESTING O DAY MEDICAL OFFICE BY JJS/GBF JOB NUMBER 0611114 DATE 2/27/2007 APPENDIX II 2 ua D D D 0 0 D ,0 D I I I I I I I I I I I I I I I I I I I 3 SOIL & TESTING INC Bo wz •»a O PHONE (619) 280 4321 TOLL FREE (877) 215 4321 FAX (619) 280 4717 San Diego Office PO Box 600627 San Diego CA 92160 0627 6280 Riverdale Street San Diego CA 92120 www scst com PHONE (760}"775 5983 TOLL FREE (877) 215 4321 FAX (760) 775 8362 Indio Office 83 740 Citrus Avenue Suite G Indio CA 92201 3438 www scst com SHORING RECOMMENDATIONS FOR O'DAY MEDICAL OFFICE BUILDING 2020 CASSIA ROAD CARLSBAD, CALIFORNIA PREPARED FOR MR PAT O'DAY O DAY CONSULTANTS 2710 LOKER AVENUE WEST CARLSBAD, CALIFORNIA 92008 PREPARED BY SOUTHERN CALIFORNIA SOIL & TESTING, INC 6280 RIVERDALE STREET SAN DIEGO, CALIFORNIA 92120 Providing Professional Engineering Services Since 1959 I I I I I I I I I I I I I I I I I I I <* SOIL & TESTING INCz BOIh ^<t OM PHONE (619) 280 4321 TOLL FREE (877) 215 4321 FAX (619) 280 4717 San Diego Office PO Box 600627 San Diego CA 92160 0627 6280 Riverdale Street San Diego CA 92,120 www scst com PHONE (760) 775 5983 TOLL FREE (877) 215 4321 FAX (760) 775 8362 Indio Office 83 740 Citrus Avenue Suite G Indio CA 92201 3438 www scst com February 26 2007 , SCS&TNo 0611114 Report No 5 Mr Pat O Day O Day Consultants 2710 Loker Avenue West Carlsbad California 92008 Subject SHORING RECOMMENDATIONS O DAY MEDICAL OFFICE BUILDING 2020 CASSIA ROAD CARLSBAD CALIFORNIA Reference Keystone Retaining Wall Plans For Cassia Professional Offices All Cats Hospital Keystone Retaining Wall Plans Sheets 1 to 5 prepared by Southern California Soil and Testing Inc dated December 21 2006 Dear Mr ODay i i In accordance with a request from Mr Erik Nelson of Pacific Building Group this letter has been prepared to provide shoring recommendations for the subject project We understand ( improvements will consist of a road widening supported by a Keystone wall and a curb inlet structure The site is underlain by undocumented fill and formational material commonly identified as the Santiago Formation To determine the extent of the fill along the planned wall alignment SCS&T drilled 3 borings at the locations indicated on Figure 1 The fill was determined to range from approximately 10 to 25 feet in depth thickening to the south and east The fill consists of soft clays and loose clayey sands The boring logs are presented in Appendix I Laboratory testing performed on the sample is presented in Appendix II Shoring along El Cammo Reial will be required to support excavations for the construction of the planned wall and curb inlet structure » It is anticipated that soldier beams with tiebacks and lagging will be utilized ranging from about 15 to 27 feet in height starting at wall Station 2+80 and ending at Station 4+00 Areas north and south of the shored area can be cut temporarily at an inclination of 1 (H) 1 (V) with a 5 foot vertical at fhe toe of the slope Cross section A A, Figure 2 shows the anticipated top and bottom elevation of the shoring along El Cammo Real Typical sections through the most critical areas are shown on Figures 3 and 4 / The design parameters to calculate the earth pressures on shoring are presented in Table 1 1 1 •1 1 1 • 1 1••P 1 1 • 1 • 1 1 • 1 1 O Day Consultants February 26 2007 O Day Medical Office Building SCS& TNo 06111145 2020 Cassia Rd Carlsbad CA , Page 2 Table 1 Total Unit Weight Cohesion Value Material Pounds Per Cubic AT-i^eS. Pounds per Square Foot Angle" Phl Foot Fill 125 27 100 Formation 135 35 500 An active condition can be applied to shoring that is capable of rotating 0 002 radians An at rest condition should be applied to a shoring system that is unyielding and not able to rotate Construction surcharge loads should be evaluated on a case by case basis Soils should no be stockpiled at the top of slopes or at the top of the shoring Vertical and lateral movements of the temporary shoring are expected to be small assuming an adequate lateral support systemi- If any other surcharge loads are anticipated SCS&T should be contacted for the necessary increase in soil pressure The passive pressure for the design of the proposed shormg system may be considered to be 350 psf per foot of depth up to a maximum of 5 000 psf The passive pressure may be assumed to act on an area equal to twice the soldier beam diameter This value may be increased by 1/3 for seismic loading The upper 1 foot of embedment should be neglected when 1calculating passive pressures Survey monuments should be installed at no more than 40 foot intervals along the perimeter of the excavation One row of monuments should be located just beyond the edge of the top of excavation A second row should be established 10 feet beyond the excavation and a third row should be set 20 feet from the top of the excavation A reference\ point should be established well away from the block where the excavation will take place The horizontal and vertical location of each monument should be established with a survey instrument before excavation starts Readings should be made daily during the initial stages of excavation say for up to one week Results of the initial readings will be reviewed by SCS&T and modifications to the monitoring schedule may be made depending on these results Significant sloughing and erosion of the slopes should be anticipated In addition construction activities above or near the slopes could affect overall stability The slopes should be observed by a representative of SCS&T periodically to ascertain that no unforeseen adverse conditions are observed The temporary slopes should be inspected daily by the contractor s Competent Person before personnel are allowed to enter the excavation Zones of potential instability sloughing or raveling should be brought to the attention of the Engineer and corrective action f~ flfk V ^ --S^w""\ O Day Consultants N 0 Day Medical Office Building 2020 Cassia Rd Carlsbad CA February 26 2007 SCS&TNo 06111145 Page3 implemented before personnel begin working in the trench No surcharge loads should be placed within a distance from the top of temporary cut slopes equal to half the slope height This opportunity to be of professional service is sincerely appreciated IA SOIL & TESTING, INC Respe; SO DBAkv (4) Addressee ( (1) Pacific Building Group Attn Erik Nelson via email Erik©pacificbuildmggroup com (1) Anderson Drilling Attn Mike Empizo via email - mempizo@andersondrilling com\ Attachments Figures 1234 Appendix I Appendix II L_to-J<J\10CD roCOOlI COOI roCOen coooI cooCn01 roo roen coo coen I I IM I I I I I I I I I I I I I I I I II I I I I I I I I I I I I I I I I O>c/>m « £ +,> -U -^F 01 _m H ~ -i 2 ° c/>n = w rn en D r? m w.jpi .A Ol 01 — {0) o zo o> T£ <In •n (Sc CO 03 0 6oo 0 (? M o 0d 5 m 0 o i- 01 F 02 o /M^\ H'O"" f 00 00 0 0 fv £3 Hj Ww s 00 ^3 nZ> PC L^ J J.J Z2n g > •^ H ^jO rnSO >o a» s Tl ^**1 1 r~ 'ro I" _|- CD o m > 5 5 0 m P ^1 1 1 1 1 1 - | W ^ro ro ro ro ro co co->J 00 00 CD CO O Oen o en o en o en ~~- 4 •o S? § "*" ^ I O CO > <D W 3.o 2. aQ S Qc5 of, ED 0 O ~ g* O1 = w | I 09o09 5 O §O 10->1cnI 1000OI 00Cn 10COO roCDcnI coOO coOcn O oI I I I I I I I I I I II I I I I I I I I I I I cncn O zo o>O Tl D O (QC 0)1^ 9 NJ od 5 mg o 03c g o CO CO 0 0i—i ,—ir s CO PCw SZ 0n 2 ro^icn ro 00o rooocn roCOo 10COcn COoo COocn O CO<D Q)Q J <e So off11o = CQ GO § r I I I I I I I APPENDIX I SUBSURFACE EXPLORATION LEGEND UNir ILD SOIL CLASSII ICA T ION CHAR P SOIL DLSCRIPI ION VYMRfir tYUCAL NAMES^ I COARSE ( RAINED more than half of material is larger than No G_RAV_ELS_ CLEAN GRAVELS GW More than half ol coaise fraction is larger than No 4 GP sieve si/e but smaller than 3 GRAVEI S WITH FINFS GM (Appreciable amount ol fines) CC SANDS CLEAN SANDS SW More than half of coarse traction is smaller than No 4 SP sieve size SANDS WITH HNtS SM (Appreciable amount of fines) SC 200 sieve size Well graded gravels gravel sand mixtures little or no fines Poorly graded gravels gravel sand mixtures little or no lines Silty yavels poorly graded gravel sand silt mixtures Clayey travels poorly graded travel sand clay mixtures Well graded sand gravelly sands little or no fines Poorly graded sands gravelly sands little or no fines Silty sands poorly graded sind and silty mixtures C layey sands pooilv grad d sand and clay mixtures II FINP TRAINED more than half of material is smaller than No 20(1 sieve si/e SILTS AND CLAYS ML Inorganic silts and very line sands rock flour sandy silt Liquid Limit less than SO or clayey silt sand mixtures with slight plasticity CL Inorganic clays ot low to medium plasticity grivclly elays bandy clays silty clays lean clays OL Organic silts and organic silty clays or low plasticity SILTS AND CLAYS MH Liquid Limit greater than 50 CH OH III HIGHLY ORGANIC SOILS PT ^ Water level at time of excavation or as indicated US Undisturbed driven ring sample or tube sample SC Sand Cone CON Consolidation El Expansion Index MS Maximum Size of Particle MAX Maximum Density ST Shelby Tube SPT Standard Penetration Sample pH pH & Resistivity SF/C L Sulfate & Chloride Inorganic silts micaceous or diatomaeeous line sandy or silty soils elastic silts Inorganic clays of high plasticity fit clays Organic elays ot medium to high plasticity Peat ind other highly organic soils C K. Undisturbed chunk sample E3 Bulk Sample DS Direct Shear SA Sieve Analysis PI Plasticity Index RC Relative Compaction UC Uneonfmed Compression TX Triaxial Compression RS Ring Shear AL Atterberg Limits RV R Value Ci SOUTHERN CALIFORNIA ODAY MEDICAL OFFICE BUILDING ROAD WIDENING (Gm SOIL & TESTING INC BY \»-^V- JOB NUMBER DBA DATE 2/26/2007 0611114 APPENDIX! 11 LOG OF EXPLORATORY BORING NUMBER B-1 Date Excavated 2/16/2007 Equipment CME 55 Surface Elevation (ft) 303 ^-, J^~^DEPTH- 2 A - b - 8 in - 12 - 14 - 1b - 18 on O)O o SM CL SC CL Logged by MM Project Manager GBF Depth to Water (ft) N/A SUMMARY OF SUBSURFACE CONDITIONS ASPHALT 6 Inches FILL(Qaf) Brown moist dense SILTYSAND ASPHALT 3 inches FILL(Qaf) Brown to gray moist soft SILTYCLAY FILL(Qaf) Light brown moist loose to medium dense CLAYEY SAND FILL(Qaf) Dark brown moist soft SANDY CLAY O. SOUTHERN CALIFORNIA 1 SV SOIL & TESTING, INC•^J^. SAMPLES 0LUCQOLID tt> Q D _i CO I y Y A usH z ?O c I? % *sy »iu §3 13w n US I | 19 I US 15 ??STUREO2 (_. Q. 1- 1-z a:Q W ' a>ai v RATOR'O CQ3 ODAY MEDICAL OFFICE BUILDING ROAD WIDENING BY AP/GBF JOB NUMBER 0611114 DATE 2/26/2007 APPENDIX I I 2 LOG OF EXPLORATORY BORING NUMBER B-1 (continued) Date Excavated 2/17/2007 Logged by MM Equipment CME 55 Project Manager GBF Surface Elevation (ft) 303 Depth to Water (ft) N/A 1ID Q -22 -24 - 26 - 28 -30 - 32 - 34 - 36 - 38 L 40 CO O CO SM SM \ SUMMARY OF SUBSURFACE CONDITIONS FILL(Qaf) Ligth brown to tan moist dense SILTY SAND SANTIAGO FORMATION(Ts) Light brown moist very dense SILTY SAND PRACTICAL REFUSAL @ 26 FEET SAMPLES UNDISTURBEDUS m PENETRATION(blows/ ft of drive)53 MOISTURE (%)•5 ^-z DC Q LABORATORY TESTS. .. Cl \tm,*s%^ SOUTHERN CALIFORNIA ° DAY MEDICAL OFFICE BUILDING ROAD WIDENING SOIL & TESTING, INC BY AP/GF JOB NUMBER 0611114 DATE 2/27/2007 APPENDIX I I 3 LOG OF EXPLORATORY BORING NUMBER B-2 Date Excavated 2/16/2007 Equipment CME 55 Surface Elevation (ft) 303 X Q.LUQ - 2 - 4 - 6 - 8 - 10 - 12 - 14 - 16 - 18 -20 COO CO SM CL ML SM Logged by MM Project Manager GBF Depth to Water (ft) N/A SUMMARY OF SUBSURFACE CONDITIONS ASPHALT 6 Inches FILL(Qaf) Brown moist dense SILTYSAND FILL(Qaf) Brown to gray moist soft CLAY FILL(Qaf) Light brown to tan moist stiff SANDY SILT SANTIAGO FORMATION(Ts) SILTY SAND Light brown moist very dense REFUSAL® 17 FEET CjL SOUTHERN CALIFORNIA (a V SOIL * TESTING. INC SAMPLES UNDISTURBEDUS us us CO PENETRATION[blows/ ft of drive)12 25 71 MOISTURE (%)S_Q. H 13 Q MORATORY TESTS_! ODAY MEDICAL OFFICE BUILDING ROAD WIDENING BY AP/GBF JOB NUMBER 0611114 DATE 2/26/2007 APPENDIX I I 4 LOG OF EXPLORATORY BORING NUMBER B-3 Date Excavated 2/16/2007 Equipment CME 55 Surface Elevation (ft) 303 ~ I 0.LU Q - 2 - A - 6 . - 8 10 - 12 - 14 - 16 - 18 _ 9n CO CO sw CL SM Logged by MM Project Manager GBF Depth to Water (ft) N/A SUMMARY OF SUBSURFACE CONDITIONS ASPHALT 6 Inches FILL(Qaf) Brown moist dense WELL GRADED SAND FILL(Qaf) Brown to gray moist soft SILTYCLAY SANTIAGO FORMATION(Ts) SILTY SAND Light brown moist very dense SIL REFUSAL® 15 FEET C Q^ SOUTHERN CALIFORNIA 1 S*d SOIL & TESTING, INCX*^V SAMPLES QLUCQ(E 3 CO Dz ID US US _i GO vA/\ z f H .?g;yj -s UJ § 3 17 73 ^111 QL -3 co O2 £-. Q. K Z3 Q CO COLU £OiO CD 5 ODAY MEDICAL OFFICE BUILDING ROAD WIDENING BY AP/GBF JOB NUMBER 0611114 DATE 2/26/2007 APPENDIX I I 5 APPENDIX II <t&kvv^x^ 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 s/ 50 45 40 35 f in £ 25 W b.(0 CO 20 15 10 05 00 0 Direct Shear Test Results • Shear Strength at 0 2 inches of Deformation • • + ' - i " ,m* ^ 0 05 10 15 20 25 30 35 40 Confining Pressure (ksf) 45 50 INTERNAL COHESION FRICTION INTERCEPT WIPLE DESCRIPTION ANGLE(DEG ) (PSF) B2@6 6 5 Shear Strength at Tan Clayey Sand 27 98 0 2 inches of Deformation 'S O. SOUTHERN CALIFORNIA f S^TT/ SOIL & TESTING%J^ .T-^w^^a^»f<***^ ' ^;»«.~ O DAY MEDICAL OFFICE BY JJS/GBF JOB NUMBER 0611114 DATE 2/27/2007 APPENDIX II 1 I I I I I I I I I I I I I I I I I I I sx 50 45 40 35 I" 8 £ 25co 1001 CO 20 15 10 05 00 0 Direct Shear Test Results • Shear Strength at 02 inches of Deformation <i »' *f 0 05 10 15 20 25 30 35 40 Confining Pressure (ksf) 45 50 INTERNAL COHESION FRICTION INTERCEPT \MPLE DESCRIPTION ANGLE(DEG ) (PSF) B1@11 11 5 Shear Strength at Brown Clay 33 333 0 2 inches of Deformation S C- SOUTHERN CALIFORNIA jM^nCf SOIL * TESTING 0 DAY MEDICAL OFFICE BY JJS/GBF JOB NUMBER 0611114 DATE 2/27/2007 APPENDIX II 2