HomeMy WebLinkAbout2020 CASSIA RD; ; CB072242; Permit09-13-2007 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Retaining Wall Permit Permit No CB072242 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Valuation Reference # Project Title 2020 CASSIA RD CBAD RETAIN 2150210200 Lot# $94,14000 Construction Type 0 NEW CASSIA OFFICES-5230 SF GEOGRID KEYSTONE WALL Status Applied Entered By Plan Approved Issued Plan Check# Inspect Area ISSUED 08/29/2007 RMA 09/13/2007 09/13/2007 Applicant O'DAY CONSULTANTS 760931-7700 Owner FRANZ FAMILY REVOCABLE TRUST 06-26-96 PO BOX 2711 RANCHO SANTA FE CA 92067 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Strong Motion Fee Renewal Fee Add'l Renewal Fee Other Building Fee Additional Fees $527 31 $000 $342 75 $000 $941 $000 $000 $000 $000 TOTAL PERMIT FEES $879 47 Total Fees $879 47 Total Payments To Date $879 47 Balance Due $000 BUILDING PLANS _jL IN STORAGE ATTACHED K8" SEC HOM 108 4 A Ao f ix '•*•"'•' DA-5EJ Inspector FINAL APPROVAL Date Clearance NOTICE Please lake NOTICE that approval of your project includes the Imposition' of fees dedications reservations, or other exactions hereafter collectively referred to as fees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them you must follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review set aside, void or annul their imposition You arc hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes nor planning zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any lees'uxactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired 0 PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635FaradayAve,Carlsbad CA 92008 FOR OFFICE USE ON]_Y PLAN CHECK NO L^T ^/j [) ^/ fT^ol Plan Ck Depos Validated By Date ii^^^'5!^lH^^ii;'^-^-i^j.fc * «•.&*:<£ rs.^'-^..-^ Address (include Bids/Suite #)Business Name (at this address) Legal Description .2/5-- Lot No Subdivision Name/Number Assessor's Parcel 0 Exlstlnq,.Use Unit No ' \ AS Phase No Total * of units Proposed Use Description of Wo rt(n of Bedrooms K of Bathrooms _ Namemm Address City State/Zip Fax* Name Address State/Zip Telephone # Name Address City State/Zip Telephone # (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, Improve, demolish or repair any structure, prior to its Issuance, Section 7000 of Division 3 of the Business and Professions Code] or that he Is exempt therefrom, and the basis for the alleged exemption Any violation of Section 7031 5 applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]) C.T, Name State License # Address License Class ff. C.- City State/Zip City Business License #. Telephone # Designer Name State License # Address City State/Zip Telephone # K^fW^^ stZX."^ •"- X-.^ -'• ^..-». . . ..... ^&£t^'A^tii,yZ.&&*4?.**t-* Lil.^l:^l.«. i ?1^ fevi?" K&&«>1 It. Avtf. **&&*••-*.. ^ Jvlf >'&4. 'JJ !f-lv"^:J^O/~ '--. ,1T^J -<*, .A!., i^k/^ :.t i -.. -,-'.,. e; U Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations Q I have and will maintain a certificate of consent to self-Insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit Is Issued ff I have and will maintain worker's compensation, as required by Section 3700 of the labor Code, for the performance of the work for which this permit Is Issued My worker's compensation Insurance carrier and policy number are Insurance Company ()L0 /ZGPC&./C. ff&V&Z/fc //^Tpoiicv No A/C.U3f#yO'?®3 Expiration Date 3/1/2.O&!? _ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) ' D CERTIFICATE OF EXEMPTION I certify that In the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California WARNING Failure to »ecur« workers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand , l x^ollnredl 00,000), In addition to the cost of compensation, damages are provided for In Section 3706 of the Labor Code, Interest and attorney's fees SIGNATURE DATE _ I hereby affirm that I am exempt from the Contractor's License Law for the following reason Q I as owner of the property or my employees with wages as their sole compensation, will d the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees provided that such Improvements are not Intended or offered for sale If, however the building or improvement Is sold within one year of completion the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) ^ I as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) D I am exempt under Section _ Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement DYES D NO 2 I (have/have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / /ontractors license number) _ _^ _ 5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) PROPERTY OWNER SIGNATURE DATE WHITE F((gXYELLOW Applicant PINK Finance PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave, Carlsbad CA 92008 i Page 2 of 2 Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration for or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? DYES 8 NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES pi NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES ft NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I hereby affirm that there Is a construction lending agency for the performance of the work for which this permit is Issued (Sec 3097(1) Civil Code) LENDER'S NAME ^ffCOUGTZ <*? g/HUK LENDER'S ADDRESS &?f V'A V<£>*<4 &2U-Z . I certify that I have read the application and state that the above information Is correct and that the Information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGEMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit Is required for excavations of 5'OT deep and demolition or construction of structures over 3 stories In height. EXPIRATION Every permit Issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work Is commenced for a period of 180 days (Section 106 4 4 Uniform Building Code) I APPLICANT'S SIGNATURE . DATE.C///7 WHITE File YELLOW Applicant PINK Finance City of Carlsbad August 27, 2008 PACIFIC BUILDING GROUP 9752 ASPEN CREEK CT #150 SAN DIEGO CA 92126 RE: BUILDING PERMIT EXPIRATION PERMIT TYPE: RETAIN Building Department Permit Number CB072242 Issue Date 09/13/2007 ADDRESS: 2020 CASSIA RD PLEASE CALL FOR AN INSPECTION IF WORK IS COMPLETE Our records indicate that your building permit will expire by limitation of time on 09/11/2008 The provisions of UBC, Section 106 4 4 as amended by the Carlsbad Municipal Code state "EXPIRATION Every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is stopped at any time after the work is commenced for a period of 180 days or if the building or work authorized by such permit exceeds three calendar years from the issuance date of permit Work shall be presumed to have commenced if the permittee has obtained a required inspection approval of work authorized by the permit by the Building Official within 180 days of the date of permit issuance Work shall be presumed to be stopped if the permittee has not obtained a required inspection approval of work by the Building Official within each 180 day period upon the initial commencement of work authorized by such permit Before such work can be recommenced, a new permit shall be obtained to do so, and the fee, therefore, shall be one-half the amount required for a new permit for such work, and provided that no changes have been made or will be made in the original plans and specifications for such work, and provided further that such suspension or abandonment has not exceeded one year In order to renew action on a permit after expiration, the permittee shall pay a new permit fee Any person holding an unexpired permit may apply for an extension of the time within which work may commence under that permit when the permittee is unable to commence work within the time period required by this section for good and satisfactory reasons The Building Official may extend the time for action by the permittee for a period not exceeding 180 days on written request by the permittee showing that circumstances beyond the control of the permittee have prevented action from being taken No permit shall be extended more than once Please check below indicating your intentions and return this letter to us Project abandoned A new permit will be obtained prior to commencing work No fee extension requested for 180 days (attach a letter of explanation) Renewal permit requested If the project has been completed and only a final inspection is needed, please call the inspection request line at (760) 602-2725 If you have any questions, please contact the Building Inspection Department at (760) 602-2700 Christine Wauschek Office Specialist 1635 Faraday Avenue • Carlsbad, CA 92008 • (760) 602-4660 • FAX (760) 602-8561 City of Carlsbad February 28, 2008 PACIFIC BUILDING GROUP 9752 ASPEN CREEK CT #150 SAN DIEGO CA 92126 RE- BUILDING PERMIT EXPIRATION PERMIT TYPE- RETAIN Building Department Permit Number CB072242 Issue Date 09/13/2007 ADDRESS: 2020 CASSIA RD PLEASE CALL FOR AN INSPECTION IF WORK IS COMPLETE Our records indicate that your building permit will expire by limitation of time on 03/11/2008 The provisions of UBC, Section 106 4 4 as amended by the Carlsbad Municipal Code state "EXPIRATION Every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit (unless issued prior to 7/1/99 which is one year from date of permit), or if the building or work authorized by such permit is stopped at any time after the work is commenced for a period of 180 days or if the building or work authorized by such permit exceeds three calendar years from the issuance date of permit Work shall be presumed to have commenced if the permittee has obtained a required inspection approval of work authorized by the permit by the Building Official within 180 days of the date of permit issuance Work shall be presumed to be stopped if the permittee has not obtained a required inspection approval of work by the Building Official within each 180 day period upon the initial commencement of work authorized by such permit Before such work can be recommenced, a new permit shall be obtained to do so, and the fee, therefore, shall be one-half the amount required for a new permit for such work, and provided that no changes have been made or will be made in the original plans and specifications for such work, and provided further that such suspension or abandonment has not exceeded one year In order to renew action on a permit after expiration, the permittee shall pay a new permit fee Any person holding an unexpired permit may apply for an extension of the time within which work may commence under that permit when the permittee is unable to commence work within the time period required by this section for good and satisfactory reasons The Building Official may extend the time for action by the permittee for a period not exceeding 180 days on written request by the permittee showing that circumstances beyond the control of the permittee have prevented action from being taken No permit shall be extended more than once Please check below indicating your intentions and return this letter to us Project abandoned A new permit will be obtained prior to commencing work No fee extension requested for 180 days (attach a letter of explanation) Renewal permit requested If the project has been completed and only a final inspection is needed, please call the inspection request line at (760) 602-2725 If you have any questions, please contact the Building Inspection Department at (760) 602-2700 Christine Wauschek Office Specialist 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-2700 • FAX (760) 602-8560 City of Carlsbad February 28, 2008 Building Department Permit Number CB072242 Issue Date 09/13/2007 TIM CARROLL 2710LOKERAVE WEST CARLSBADCA 92010 RE: BUILDING PERMIT EXPIRATION PERMIT TYPE: RETAIN ADDRESS: 2020 CASSIA RD PLEASE CALL FOR AN INSPECTION IF WORK IS COMPLETE Our records indicate that your building permit will expire by limitation of time on 03/11/2008 The provisions of UBC, Section 106 4 4 as amended by the Carlsbad Municipal Code state "EXPIRATION Every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit (unless issued prior to 7/1/99 which is one year from date of permit), or if the building or work authorized by such permit is stopped at any time after the work is commenced for a period of 180 days or if the building or work authorized by such permit exceeds three calendar years from the issuance date of permit Work shall be presumed to have commenced if the permittee has obtained a required inspection approval of work authorized by the permit by the Building Official within 180 days of the date of permit issuance Work shall be presumed to be stopped if the permittee has not obtained a required inspection approval of work by the Building Official within each 180 day period upon the initial commencement of work authorized by such permit Before such work can be recommenced, a new permit shall be obtained to do so, and the fee, therefore, shall be one-half the amount required for a new permit for such work, and provided that no changes have been made or will be made in the original plans and specifications for such work, and provided further that such suspension or abandonment has not exceeded one year In order to renew action on a permit after expiration, the permittee shall pay a new permit fee Any person holding an unexpired permit may apply for an extension of the time within which work may commence under that permit when the permittee is unable to commence work within the time period required by this section for good and satisfactory reasons The Building Official may extend the time for action by the permittee for a period not exceeding 180 days on written request by-the permittee showing that circumstances beyond the control of the permittee have prevented action from being taken No permit shall be extended more than once Please check below indicating your intentions and return this letter to us Project abandoned A new permit will be obtained prior to commencing work No fee extension requested for 180 days (attach a letter of explanation) Renewal permit requested If the project has been completed and only a final inspection is needed, please call the inspection request line at (760) 602-2725 If you have any questions, please contact the Building Inspection Department at (760) 602-2700 Christine Wauschek Office Specialist 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-2700 • FAX (760) 602-8560 00)T_(fl(7 _i£So"°£-^o> <ro oO 3o c00 CDCO oo0)M .?>' CLASS EsGil Corporation In (Partnership -with government for <BuiCding Safety DATE 9/10/07 JURISDICTION City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 072242 SET I PROJECT ADDRESS 2O20 Cassia Road PROJECT NAME Keystone Retaining Wall #1 XI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to XI Esgil Corporation staff did not advise the applicant that the plan check has been completed I Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Fax # Mail Telephone Fax In Person XI REMARKS City to approve the special inspection program By David Yao Enclosures Esgil Corporation D GA D MB D EJ D PC 9/4 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 City of Carlsbad O72242 9/10/O7 VALUATION AND PLAN CHECK FEE JURISDICTION City of Carlsbad PLAN CHECK NO O72242 PREPARED BY David Yao DATE 9/10/07 BUILDING ADDRESS 202O Cassia Road BUILDING OCCUPANCY TYPE OF CONSTRUCTION BUILDING PORTION retaining wall Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) 5230 cb Valuation Multiplier 1774 By Ordinance Reg Mod VALUE ($) 92,780 92,780 Bldg Permit Fee by Ordinance j Plan Check Fee by Ordinance i' Type of Review I I Repetitive Fee Repeats Complete Review D Other i—I Hourly Structural Only Hour* Esgil Plan Review Fee Comments $566 85 $368 45 $31744 Sheet 1 of 1 macvalue doc :#^" City of Carlsbad 06274O 10/6/06 City of Carlsbad BuiIding Department BUILDING DEPARTMENT NOTICE OF REQUIREMENT FOR SPECIAL INSPECTION Do Not Remove From Plans Plan Check No. 062740 Job Address or Legal Description 2O1O Cassia Address 2-7 lo LQkEfr Av£. tS&Sr f Suc^ Joe> CAM I AJO, U-C. You are hereby notified that in addition to the inspection of construction provided by the Building Department, an approved Registered Special Inspector is required to provide continuous inspection during the performance of the phases of construction indicated on the reverse side of this sheet The Registered Special Inspector shall be approved by the City of Carlsbad Building Department prior to the issuance of the building permit Special Inspectors having a current certification from the City of San Diego, Los Angeles, or ICBO are approved as Special Inspectors for the type of construction for which they are certified The inspections by a Special Inspector do not change the requirements for inspections by personnel of the City of Carlsbad building department The inspections by a Special Inspector are m addition to the inspections normally required by the County Building Code The Special Inspector is not authorized to inspect and approve any work other than that for which he/she is specifically assigned to inspect The Special Inspector is not authorized to accept alternate materials, structural changes, or any requests for plan changes The Special Inspector is required to submit written reports to the City of Carlsbad building department of all work that he/she inspected and approved The final inspection approval will not be given until all Special Inspection reports have been received and approved by the City of Carlsbad building department. Please submit the names of the inspectors who will perform the special inspections on each of the items indicated on the reverse side of this sheet. (over) LOO/ 900'd ZSJfi* SZ LI OOCZ City of Carlsbad O6274O 10/6/06 SPECIAL INSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION: ^ Op>£> CA ^») fl PLAN CHECK NUMBER: O WNER'S NAME:/ A/O, I, as the owner, or agent of the owner (contractors may not employ the special inspector) certify that I, or the architect/engineer of record, will be responsible for employing the special inspectors) as required by Uniform Building Code (UBC) Section 1701 1 for the construction project located at the site listed above. UBC Section 106 3 5. Signed I, as the engmeeffarchitect of recolrd, certify that I have prepared the following special inspection program as required by UBC Section 106 3 5 for the construction project located at the site listed above. Signed 1. List of work requiring special inspection: Q Soils Compliance Prior to Foundation Inspection D Field Welding D Structural Concrete Over 2500 PSI G High Strength Bolting dl Prestressed Concrete CD Expansion/Epoxy Anchors f~l Structural Masonry Q Sprayed-On Fireproofing CU Designer Specified M, Other 2. Name(s) of individual(s) or firm(s) responsible for the special inspections listed above: A. 3. Duties of the special inspectors for the work listed above: A. seC-7 /d AJ Special inspectors shall check m with the City and present their credentials for approval pnpr to beginning work on the job site LOO/ LOO d Z9 52 LI 0002 52 335 PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB DATE 7 ADDRESS RESIDENTIAL TENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR « $10,000.00) PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER UJAU Ctt f-Q b &~ c*»< r » o b&Ai. PLANNER DATE ENGI DATE Docs/Mlsforms/Planning Engineering Approvals e engineering me Keystone Retaining Wall Structural Calculations for All Cats Hospital (Cassia Professional Offices) City of Carlsbad, California May 2, 2007 WO #272-020 Prepared by Matthew M Merntt, P E Red One Engineering, Inc 1295 Distribution Way Vista, Ca 92081 Prepared for Geognd Retaining Wall Systems, !nc 1295 Distribution Way Vista, Ca 92081 * \) redone engineering me May 2, 2007 W O #272-020 Geognd Retaining Walls Inc 1295 Distribution Way Vista, CA 92081 Attention Mr Forrest Armentrout Subject Keystone Retaining Wall Structural Calculations All Cats Hospital (Cassia Professional Offices) City of Carlsbad, California Please find enclosed the structural wall calculations for the All Cats Hospital (Cassia Professional Offices) Keystone retaining walls The walls were designed using the KeyDraw design software, version 102 based on Rankme (modified) methodology, developed by Keystone Retaining Wall Systems, Inc The Keystone retaining wall has been designed for internal and external wall stability only The Geotechnical Engineer of Record shall confirm site global stability The General contractor/developer shall coordinate the installation of all subterranean construction within the reinforced zone Red One Engineering, Inc shall be consulted prior to any excavation within the reinforced zone All efforts shall be made too coordinate the installation of subterranean features during wall construction to limit future disturbance of the geognd reinforcement Keystone Retaining Wall Systems are active systems and may exhibit slight movement or creep over time as the geognd reinforcement elongate to develop full tensile resistance The owner should be aware that structures and pavement placed within the reinforced or retained zones of the wall may undergo movement that can lead to surface cracking It is recommended that the compacted soil in the reinforced and retained zones be allowed to consolidate for a time up to 45 days to allow for the elongation of the geognd reinforcement This will allow for any slight movement or creep to occur before placement of structures or pavement on top of the fill and further mitigate the possibility of surface cracking It is also recommended a maintenance program be implemented by the property owner to monitor and repair any cracking in the finished surface above the Keystone retaining wall to prevent water infiltration and hydrostatic pressures Soil design parameters are based on the Geotechnical Investigation by Geocon, Inc dated December 16, 2004 Request for Soils Parameters by Southern California Soil & Testing, Inc dated September 22, 2006 has been included with this submittal The current Geotechnical Engineer of Record, Southern California 1295 distribution way, vista, California 92081 phone 760 410 1665 facsimile 760 509 0078 matt@red1 engineering com Soil & Testing, Inc , shall be observing the wall installation to satisfy the special inspection requirements as noted on the Title Sheet and Notes of the Keystone Retaining Wall Plans Please contact the undersigned with any questions regarding the Keystone Retaining Wall Structural Calculations or the Keystone Retaining Wall Plans Sincerely, Red One Engineering, Inc lattheWM Merritt RCE #68429 1295 distribution way, vista, California 92081 phone 760 410 1665 facsimile 760 509 0078 matt@red1 engineering com ABBREVIATIONS: f = soil internal friction angle c = soil cohesion value g = soil unit weight in pounds per cubic foot TU|t = ultimate tensile strength RFcr = creep reduction factor RFd = durability reduction factor RFld = installation damage reduction factor LTDS = long term design strength FS = factor of safety Ta! = allowable tension TC| = peak connection tension Tsc = serviceability connection tension C, = pullout soil interaction coefficient Cds = direct shear soil interaction coefficient NOTE: Please reference calculation case number located in bold print on the middle right hand side of the KeyCAD output page with corresponding case number located on the Keystone retaining wall profiles. MM AU- #1 STONE RETAINING WALL SYSTEMS RETAINING WALL DESIGN Version Version 1 0 2 Build 126 SEISMIC DESIGN Project ALL CATS HOSPITAL Project No 272-020 Case WALL#1 Design Method' Rankme-w/Batter (modified soil interface) Design Parameters Soil Parameters Reinforced Fill Retained Zone Foundation So/I Reinforced Fill Type Unit Fill f c a pcf 31 0 126 31 0 126 34 0 113 Silts & sands Crushed Stone, 1 inch minus Peak Acceleration = 0 15 g Vertical Acceleration = OOOg Factors of Safety (seismic are 75% of static) sliding 150/1 13 pullout 150/1 13 uncertainties overturning 2 00/150 shear 150 connection bearing 2 00/150 bending 150 1 50/1 13 1 50/1 13 Reinforcing Parameters Mirafi XTc Geognds Tult RFcr RFd RFid LTDS FS Taf 3XTc 3150 160 110 105 1705 150 1136 QL 080 Cds 080 Analysis' Unit Type Leveling Pad Wall Ht BackSlope Surcharge Compact! Crushed Stone 472ft 26 60 cleg slope, LL 250 psf uniform surcharge Load Width 10000ft Case Case 8 Wall Batter OOOdeg embedment 100ft 1000 ft long DL 0 psf uniform surcharge Load Width 10000ft Results. Sliding Factors of Safety 1 69/1 29 Calculated Bearing Pressure 962/1482 psf Eccentricity at base 0 34 ft/0 84 ft Reinforcing (ft & Ibs/ft) Calc Length Tension 40 159/220 40 227/343 40 241/372 Overturning 3 10/2 13 Bearing 11 49/588 Shear 779/768 Bending 329/1 40 Height 333 1 33 067 Remf Type 3X7c 3XTc 3XTc Allow Ten 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok Pk Conn Tel 576/767 ok 772/1029 ok 837/1 116 ok Serv Conn Tsc N/A N/A N/A Pullout FS 2 21/1 28 ok 5 17/2 74 ok 6 46/3 34 ok Reinforcing Quantities (no waste included) 3XTc 1 33 sy/ft STONE RETAINING WALL SYSTEMS RETAINING WALL DESIGN Version Version 1 0 2 Build 126 SEISMIC DESIGN Project ALL CATS HOSPITAL Project No 272-020 Case WALL#1 Design Method Rankine-w/Batter (modified soil interface) Design Parameters Soil Parameters Reinforced Fill Retained Zone Foundation Soil Reinforced Fill Type Unit Fill f c & pcf 31 0 126 31 0 126 34 0 113 Silts & sands Crushed Stone, 1 inch minus Peak Acceleration = 0 15 g Vertical Acceleration = 0 00 g Factors of Safety (seismic are 75% of static) sliding 1 50/1 13 pullout 150/1 13 uncertainties overturning 2 00/150 shear 150 connection bearing 2 00/150 bending 150 1 50/1 13 1 50/1 13 Reinforcing Parameters' Mirafi XTc Geognds Tult RFcr RFd RFid LTDS FS Tal Ci 3XTc 3150 160 110 105 1705 150 1136 080 Cds 080 Analysis Unit Type Leveling Pad Wall Ht BackSlope Surcharge Compacll Crushed Stone 589ft 2660deg slope, LL 250 psf uniform surcharge Load Width 10000ft Case. Case 9 Wall Batter 0 00 deg embedment 1 00 ft 1000 ft long DL 0 psf uniform surcharge Load Width 10000ft Results Sliding Overturning Factors of Safety 1 59/1 48 ' 2 76/2 57 Calculated Bearing Pressure 1270/1538 psf Eccentricity at base 0 61 ft/0 92 ft Reinforcing (ft & Ibs/ft) Calc Length Tension 50 141/227 50 366/510 50 490/698 Bearing 9 53/6 92 Shear 484/480 Bending 303/230 Height 467 267 067 Remf Type 3XTc 3XTc 3XTc Allow Ten lal 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok Pk Conn Tel 560/746 ok 756/1008 ok 952/1269 ok Serv Conn Tsc N/A N/A N/A Pullout Ei 3 37/1 67 ok 3 79/2 18 ok 5 65/3 18 ok Reinforcing Quantities (no waste included) 3XTc 167sy/ft STONE RETAINING WALL SYSTEMS RETAINING WALL DESIGN Version Version 1 0 2 Build 126 SEISMIC DESIGN Project ALL CATS HOSPITAL Project No 272-020 Case. WALL #1 Design Method Rankme-w/Batter (modified soil interface) Date OS/37/; Design Design Parameters Soil Parameters. Reinforced Fill Retained Zone Foundation Soil Reinforced Fill Type Unit Fill f c g pcf 31 0 126 31 0 126 34 0 113 Silts & sands Crushed Stone, 1 inch minus Peak Acceleration - 0 15 g Vertical Acceleration = 0 00 g Factors of Safety (seismic are 75% of static) sliding 150/1 13 pullout 150/1 13 uncertainties overturning 2 00/150 shear 150 connection bearing 2 00/150 bending 150 1 50/1 13 1 50/1 13 Reinforcing Parameters Mirafi XTc Geogrids Tuft RFcr RFd RFid LTDS FS Tal Ci Cds 3XTc 3150 160 110 105 1705 150 1136 080 080 Analysis Unit Type Compacll -Leveling Pad Crushed Stone WallHt 706ft BackSlope 2660deg slope, Surcharge LL 250 psf uniform surcharge Load Width 10000ft Case Case 10 Wall Batter 0 00 deg embedment 1 00 ft 1000 ft long DL 0 psf uniform surcharge Load Width 10000ft Results Sliding Overturning Factors of Safety 1 54/1 45 2 54/2 42 Calculated Bearing Pressure 1599/1977 psf Eccentricity at base 0 91 ft/1 30 ft Reinforcing (ft & Ibs/ft) Calc Tension 766/263 309/43? 483/653 497/700 Reinforcing Quantities (no waste included) 3XTc 267sy/n Bearing 8 14/5 68 Shear 4 9114 86 Bending 209/1 29 Remf Type 3XTc 3XTc 3XTc 3XTc Allow Ten Tal 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok Pk Conn Tel 609/872 ok 740/987 ok 936/1248 ok 1067/1423 ok Serv Conn Tsc N/A N/A N/A N/A Pullout FS 5 40/2 72 ok 5 23/3 00 ok 6 40/3 79 ok 8 72/4 95 ok STONE RETAINING WALL SYSTEMS RETAINING WALL DESIGN Version Version 1 0 2 Build 126 SEISMIC DESIGN Project ALL CATS HOSPITAL Project No 272-020 Case WALL#1 Design Method* Rankme-w/Batter (modified soil interface) Date. 08/3, Desi Design Parameters Soil Parameters Reinforced Fill Retained Zone Foundation Soil Reinforced Fill Type Unit Fill f c g pcf 31 0 126 31 0 126 34 0 113 Silts & sands Crushed Stone, 1 inch minus Peak Acceleration = 015g Vertical Acceleration = 000g Factors of Safety (seismic are 75% of static) sliding 150/1 13 pullout 150/1 13 uncertainties overturning 2 00/150 shear 150 connection bearing 2 00/150 bending 150 1 50/1 13 1 50/1 13 Reinforcing Parameters Mirafi XTc Geogrids Tult RFcr RFd RFid LTDS FS Tal Ci Cds 3XTc 3150 160 110 105 1705 150 1136 080 080 Analysis Unit Type Compacll Leveling Pad Crushed Stone Wall Ht 8 23 ft BackSlope 2660deg slope, Surcharge LL 250 psf uniform surcharge Load Width 10000ft Case Case 11 Wall Batter OOOdeg embedment 100ft 1000 ft long DL 0 psf uniform surcharge Load Width 10000ft Results Sliding Overturning Factors of Safety 1 52/1 44 2 42/2 33 Calculated Bearing Pressure 1929/2425 psf Eccentricity at base 1 20 ft/1 66 ft Reinforcing (ft & Ibs/ft) Calc Tension 146/240 295/411 586/735 515/710 448/664 Reinforcing Quantities (no waste included) 3XTc 389sy/ft Bearing 7 25/4 88 Shear 360/357 Bending 2 51 /1 57 Reinf Type 3XTc 3XTc 3XTc 3XTc 3XTc Allow Ten Tal 11 36/1 939 ok 11 36/1 939 ok 1136/1939 ok 11 36/1 939 ok 11 36/1939 ok Pk Conn 593/791 ok 724/966 ok 920/1 227 ok 11 17/1 489 ok 11 82/1 576 ok Serv Conn Tsc N/A N/A N/A N/A N/A Pullout FS 7 42/3 61 ok 6 32/3 62 ok 5 85/3 73 ok >10/6 15 ok >10/7 52 ok STONE RETAINING WALL SYSTEMS RETAINING WALL DESIGN Version Version 1 0 2 Build 126 SEISMIC DESIGN Project ALL CATS HOSPITAL Project No 272-020 Case WALL#1 Design Method Rankme-w/Batter (modified soil interface) Design Parameters Soil Parameters Reinforced Fill Retained Zone Foundation Soil Reinforced Fill Type Unit Fill f c g pcf 31 0 126 31 0 126 34 0 113 Silts & sands Crushed Stone, 1 inch minus Peak Acceleration = 0 15 g Vertical Acceleration = OOOg Factors of Safety (seismic are 75% of static) sliding 150/1 13 pullout 150/1 13 uncertainties overturning 2 00/150 shear 150 connection bearing 2 00/150 bending 150 1 50/1 13 1 50/1 13 Reinforcing Parameters Mirafi XTc Geogrids 3XTc Tult 3150 RFcr 1 60 RFd 1 10 RFid 1 05 LTDS 1705 FS 1 50 Tal 1136 Ci 080 Cds 080 Analysis Unit Type Compacll Leveling Pad Crushed Stone WallHt 1005ft BackSlope 2660deg slope, Surcharge LL 250 psf uniform surcharge Load Width 10000ft Case: Case 12 Wall Batter 0 00 deg embedment 100ft 1000 ft long DL 0 psf uniform surcharge Load Width 10000ft Results Sliding Overturning Factors of Safety 1 51/1 62 2 62/2 73 Calculated Bearing Pressure 2275/2679 psf Eccentricity at base 1 59 ft/2 07 ft Reinforcing (ft & Ibs/ft) Calc. Tension Bearing 7 90/5 89 Shear 294/292 Bending 286/1 98 Layer 6 5 4 3 2 1 Height 867 733 533 333 733 067 Length 95 95 95 95 95 95 125/247 286/433 572/736 799/982 650/879 547/797 Reinforcing Quantities (no waste included) 3XTc 633sy/ft Reinf Type 3X7c 3XTc 3XTc 3XTc 3XTc 3XTc Allow Ten Tal 11 36/1939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok Pk Conn Tel 576/768 ok 707/942 ok 903/1204 ok 1099/1466 ok 1260/1680 ok 1266/1 687 ok Serv Conn Tsc N/A N/A N/A N/A N/A N/A Pullout Ei >10/6 69 ok >10/5 73 ok 8 83/5 49 ok 9 35/6 09 ok >10/9 43 ok >10/>10ok STONE RETAINING WALL SYSTEMS RETAINING WALL DESIGN Version Version 1 0 2 Build 126 SEISMIC DESIGN Project ALL CATS HOSPITAL Project No 272-020 Case WALL#1 Design Method: Rankme-w/Batter (modified soil interface) Design Parameters Soil Parameters Reinforced Fill Retained Zone Foundation Soil Reinforced Fill Type Unit Fill f c g pcf 31 0 126 31 0 126 34 0 113 Silts & sands Crushed Stone, 1 inch minus Peak Acceleration = 015g Vertical Acceleration = 000g Factors of Safety (seismic are 75% of static) sliding 150/1 13 pullout 150/1 13 uncertainties overturning 2 00/150 shear 150 connection bearing 2 00/150 bending 150 Reinforcing Parameters Mirafi XTc Geogrids 1 50/1 13 1 50/1 13 3XTc Analysis Tult RFcr RFd RFid LTDS FS 3150 1 60 1 10 1 05 1705 1 50 Unit Type Leveling Pad WallHt BackSlope Surcharge Compacll Crushed Stone 921ft 2660deg slope, LL 250 psf uniform surcharge Load Width 10000ft Tal Ci Cds 1136 080 080 Case Case 16 Wall Batter OOOdeg embedment 100ft 1000 ft long DL 0 psf uniform surcharge Load Width 10000ft Results Sliding Overturning Factors of Safety 1 52/1 55 2 58/2 60 Calculated Bearing Pressure 2092/2516 psf Eccentricity at base 1 41 ft/1 88 ft Reinforcing (ft & Ibs/ft) Calc Tension 144/264 374/524 625/806 688/908 656/909 Reinforcing Quantities (no waste included) 3XTc 4 72 sy/ft Bearing 7 90/5 69 Shear 345/342 Bending 287/248 Remf Type 3XTc 3XTc 3XTc 3XTc 3XTc Allow Ten Tal 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok Pk Conn Tcj 559/745 ok 755/1007 ok 951/1268 ok 1147/1 530 ok 1259/1679 ok Serv Conn Tsc N/A N/A N/A N/A N/A Pullout FS >10/4 61 ok 7 90/4 51 ok 7 77/4 82 ok >10/637ok >10/7 99 ok STONE RETAINING WAIL SYSTEMS RETAINING WALL DESIGN Version Version 1 0 2 Build 126 SEISMIC DESIGN Project ALL CATS HOSPITAL Project No 272-020 Case- WALL #1 Design Method Ranktne-w/Batter (modified soil interface) Date 08/31/908 / / Design Parameters Soil Parameters Reinforced Fill Retained Zone Foundation Soil Reinforced Fill Type Unit Fill- f c g pcf 31 0 126 31 0 126 34 0 113 Silts & sands Crushed Stone, 1 inch minus Peak Acceleration = 0 15 g Vertical Acceleration = 0 00 g Factors of Safety (seismic are 75% of static) sliding 150/1 13 pullout 150/1 13 uncertainties overturning 2 00/150 shear 150 connection bearing 2 00/150 bending 150 1 50/1 13 1 50/1 13 Reinforcing Parameters MirafiXTc Geogrids Tult RFcr RJFd RFid LTDS FS Ta[ Q 3XTc 3150 160 110 105 1705 150 1136 080 Cds 080 Analysis Unit Type Compacll Leveling Pad Crushed Stone Wall Hi 841ft BackSlope 2660deg slope, Surcharge LL 250 psf uniform surcharge Load Width 10000ft Case Case 18 Wall Batter OOOdeg embedment 100ft 1000 ft long DL 0 psf uniform surcharge Load Width 10000ft Results:Sliding Overturning Factors of Safety 1 55/1 50 2 54/2 50 Calculated Bearing Pressure 1920/2344 psf Eccentricity at base 1 23 ft/1 67 ft Reinforcing (ft & Ibs/ft) Calc Tension Bearing 7 83/5 53 Shear 329/327 Bending 202/1 30 Layer 4 3 2 1 Height 667 467 267 067 Length 75 75 75 75 227/357 444/623 677/888 736/1007 Reinforcing Quantities (no waste included) 3XTc 333sy/ft Remf Type 3XTc 3XTc 3XTc 3XTc Allow Ten Tal 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok Pk Conn Tel 61 1/81 5 ok 807/1076 ok 1003/1 338 ok 11 99/1 599 ok Serv Conn Tsc N/A N/A N/A N/A Pullout FJ» 6 46/3 20 ok 6 35/3 62 ok 6 92/4 22 ok 9 54/5 58 ok STONE RETAINING WALL SYSTEMS RETAINING WALL DESIGN Version Version 1 0 2 Build 126 SEISMIC DESIGN Project- ALL CATS HOSPITAL Project No. 272-020 Case WALL#1 Design Method Rankine-w/Batter (modified soil interface) Date. 08/i Design Parameters Soil Parameters Reinforced Fill Retained Zone Foundation Soil Reinforced Fill Type Unit Fill f c g pcf 31 0 126 31 0 126 34 0 113 Silts & sands Crushed Stone, 1 inch minus Peak Acceleration = 0 15 g Vertical Acceleration ~ OOOg Factors of Safety (seismic are 75% of static) sliding 150/1 13 pullout 150/1 13 uncertainties overturning 2 00/150 shear 150 connection bearing 2 00/150 bending 150 Reinforcing Parameters' Mirafi XTc Geogrids Tult RFcr RFd 7XTc 5700 1 60 1 10 3XTc 3150 1 60 1 10 1 50/1 13 1 50/1 13 RFid 1 05 1 05 LTDS 3084 1705 FS 1 50 1 50 Tal 2056 1136 Ci 080 080 Cds 080 080 Analysis Unit Type Compacll Leveling Pad Crushed Stone Wall Ht 1092ft BackSlope 2660deg slope, Surcharge LL 250 psf uniform surcharge Load Width 10000ft Case. Case 21 Wall Batter 0 00 deg embedment 100ft 1000 ft long DL 0 psf uniform surcharge Load Width 10000ft Results Sliding Overturning Factors of Safety 1 52/1 63 2 71/2 74 Calculated Bearing Pressure 2417/2845 psf Eccentricity at base 1 66 ft/2 20 ft Reinforcing (ft & Ibs/ft) Calc Tension 799/342 419/578 670/855 900/1117 715/979 591/872 Reinforcing Quantities (no waste included) 7XTc 2 33 sy/ft 3XTc 4 67 sy/ft Bearing 8 28/6 15 Shear 272/270 Bending 2 41 /1 59 Layer 6 5 4 3 2 1 Height 933 733 533 333 733 067 Remf Type 3XTc 3XTc 3XTc 3XTc 7XTc 7XTc Allow Ten Tal 11 36/1939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 2056/3509 ok 2056/3509 ok Pk Conn Tel 595/794 ok 791/1 055 ok 988/1 317 ok 11 84/1 578 ok 1320/1 760 ok 1362/1816 ok Sen/ Conn Tsc N/A N/A N/A N/A N/A N/A Pullout FS >1 0/6 79 ok >10/6 65 ok >10/6 71 ok >10/716ok >10/>10ok >10/>10ok STONE RETAINING WALL SYSTEMS RETAINING WALL DESIGN Version Version 1 0 2 Build 126 SEISMIC DESIGN Project- ALL CATS HOSPITAL Project No 272-020 Case WALL#1 Design Method Rankme-w/Batter (modified soil interface) Date Design Parameters Soil Parameters' Reinforced Fill Retained Zone Foundation Soil Reinforced Fill Type Unit Fill- f c q pcf 31 0 126 31 0 126 34 0 113 Silts & sands Crushed Stone, 1 inch minus Peak Acceleration = 0 15 g Vertical Acceleration = 0 00 g Factors of Safety (seismic are 75% of static) sliding 150/1 13 pullout 150/1 13 uncertainties overturning 2 00/150 shear 150 connection bearing 2 00/150 bending 150 1 50/1 13 1 50/1 13 Reinforcing Parameters Mirafi XTc Geognds Tult RFcr RFd RFid LTDS FS 7XTc 5700 1 60 1 10 1 05 3084 1 50 3XTc 3150 160 110 105 1705 150 IM 2056 1136 £l 080 080 Cds 080 080 Analysis Unit Type Leveling Pad Wall Ht BackSlope Surcharge Compacll Crushed Stone 13 58 ft 2660deg slope, LL 250 psf uniform surcharge Load Width 10000ft Case: Case 23 Wall Batter 0 00 deg embedment 100ft 1000 ft long DL 0 psf uniform surcharge Load Width 10000ft Results.Sliding Overturning Factors of Safety 1 53/1 61 2 77/2 54 Calculated Bearing Pressure 2933/3571 psf Eccentricity at base 1 78 ft/2 54 ft Reinforcing (ft & Ibs/ft) Calc Tension 207/369 421/672 677/899 972/7773 7720/7475 7083/7428 959/7337 Reinforcing Quantities (no waste included) 7XTc 4 00 sy/ft 3XTc 5 33 sy/ft Bearing 7 80/5 43 Shear 237/235 Bending 238/1 64 Layer 7 6 5 4 3 2 1 Height 7200 7000 800 600 400 200 067 Reinf Type 3XTc 3XTc 3XTc 3XTc 7XTc 7XTc 7XTc Allow Ten Tal 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok Pk Conn Is! 595/794 ok 791/1 055 ok 988/1 31 7 ok 11 84/1 578 ok 1320/1 760 ok 1447/1929 ok 1531/2041 ok Serv Conn Tsc N/A N/A N/A N/A N/A N/A N/A Pullout FS >70/6 84 ok >10/6 74 ok >10/6 78 ok >10/7 20 ok >10/7 89 ok >10/1000ok >10/>10ok STONE RETAINING WALL SYSTEMS RETAINING WALL DESIGN Version Version 1 0 2 Build 126 SEISMIC DESIGN Project ALL CATS HOSPITAL Project No 272-020 Case WALL#1 Design Method Rankme-w/Batter (modified soil interface) Design Parameters Soil Parameters Reinforced Fill Retained Zone Foundation Soil Reinforced Fill Type Unit Fill f c g pcf 31 0 126 31 0 126 34 0 113 Silts & sands Crushed Stone, 1 inch minus Date: 08/31/2006 Designer MMM --£A» 10 9 8 7 6 0 4 Peak Acceleration = 0 15 g Vertical Acceleration = 0 00 g Factors of Safety (seismic are 75% of static) sliding 150/1 13 pullout 150/1 13 uncertainties overturning 2 00/150 shear 150 connection bearing 2 00/150 bending 150 1 50/1 13 1 50/1 13 Reinforcing Parameters. MirafiXTc Geogrids Tult RFcr RFd RFjd 7XTc 5700 1 60 1 10 105 3XTc 3150 160 1 10 1 05 LTDS 3084 1705 FS 1 50 1 50 Tal 2056 1136 Ci 080 080 Cds 080 080 Analysis Unit Type Compacll Leveling Pad Crushed Stone Wall Ht 20 25 ft BackSlope 2660deg slope, Surcharge LL 250 psf uniform surcharge Load Width 10000ft Case Case 25 Watt Batter OOOdeg embedment 1 00 ft 1000 ft long DL 0 psf uniform surcharge Load Width 10000ft Results Sliding Overturning Factors of Safety 1 50/1 51 2 61/2 08 Calculated Bearing Pressure 4461/5998 psf Eccentricity at base 2 45 ft/3 75 ft Reinforcing (ft & Ibs/ft) Bearing 6 00/3 46 Shear 208/207 Bending 235/1 71 Layer Height 12 1867 11 1667 10 14 67 9 1267 8 1067 7 867 6 667 5 533 4 400 3 267 2 1 33 1 067 Length 150 150 150 150 150 150 150 150 150 150 150 150 Reinforcing Quantities (no 7XTc 1333sy/ft 3XTc 667sy/ft Calc Tension Reinf Type 204/336 425 / 578 686/868 927/1147 1142/1394 1344/1633 1262/1595 1106/1480 1185/1584 1263/1687 997/1462 1043/1524 waste included) 3XTc 3XTc 3XTc 3XTc 7XTc 7XTc 7XTc 7XTc 7XTc TXTc 7XTc 7XTc Allow Ten Tal 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok Pk Conn Is! 595/794 ok 791/1055 ok 988/1 31 7 ok 11 84/1 578 ok 1320/1 760 ok 1447/1929 ok 1573/2097 ok 1657/2209 ok 1741/2322 ok 1826/2434 ok 1910/2546 ok 1952/2603 ok Serv Conn Tsc N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Pullout Ei >10/6 38 ok >10/647ok >10/6 63 ok >10/7 12 ok > 10/7 86 ok >10/8 64 ok >10/>10ok >10/>10ok >10/>10ok >10/>10ok >10/>10ok >10/>10ok STONE RETAINING WALL SYSTEMS RETAINING WALL DESIGN Version Version 1 0 2 Build 126 SEISMIC DESIGN Project ALL CATS HOSPITAL Project No 272-020 Case WALL#1 Design Method Ranktne-w/Batter (modified soil interface) Date- 08/31/2006 Designer; Design Parameters Soil Parameters Reinforced Fill Retained Zone Foundation Soil Reinforced Fill Type Unit Fill f c g pcf 31 0 126 31 0 126 34 0 113 Silts & sands Crushed Stone, 1 inch minus Peak Acceleration = 0 15 g Vertical Acceleration = 0 00 g Factors of Safety (seismic are 75% of static) sliding 150/1 13 pullout 150/1 13 uncertainties overturning 2 00/150 shear 150 connection bearing 2 00/1 50 bending 150 Reinforcing Parameters MirafiXTc Geognds Tult RFcr RFd 7XTc 5700 1 60 1 10 3XTc 3150 1 60 1 10 1 50/1 13 1 50/1 13 Analysis Unit Type Leveling Pad Wall Ht BackSlope Surcharge Co Cn 22 26 LL RFid 1 05 1 05 LTDS 3084 1705 FS 1 50 1 50 Tal 2056 1136 Ci 080 080 Cds 080 080 Compacll Crushed Stone 22 92 ft 2660deg slope, LL 250 psf uniform surcharge Load Width 10000ft Case Case 26 Wall Batter 0 00 deg embedment 1 00 ft 1000 ft long DL 0 psf uniform surcharge Load Width 10000ft Results-Sliding Overturning Factors of Safety 1 52/1 52 2 65/2 06 Calculated Bearing Pressure 4993/6749 psf Eccentricity at base 2 68 ft/4 13 ft Reinforcing (ft & Ibs/ft) Calc Tension 205/334 426/574 688/865 931/1144 1147/1391 1351 / 763? 1269/1592 1112/1475 1192/1579 1270/1682 Bearing 5 85/3 33 Shear 207/206 Bending 234/1 73 Layer Height 2733 7933 7733 7533 7333 7733 933 800 667 14 13 12 11 10 9 8 7 6 K 4 400 165 1351/1793 3 267 165 1428/1895 2 133 165 1121/1629 1 067 165 1163/1684 Reinf Type 3XTc 3XTc 3XTc 3XTc 7XTc 7XTc 7XTc 7XTc 7XTc 7XTc 7XTc 7XTc 7XTc 7XTc Allow Ten Tal 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok Pk Conn Tel 595/794 ok 791/1055 ok 988/1 317 ok 11 84/1 578 ok 1320/1 760 ok 1447/1929 ok 1573/2097 ok 1657/2209 ok 1741/2322 ok 1826/2434 ok 1910/2546 ok 1994/2659 ok 2031/2708 ok 2031/2708 ok Serv Conn Tsc N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Pullout FS >1 '0/6 42 ok > 10/6 50 ok >10/6 66 ok >10/719ok >1 0/7 97 ok >1 0/8 79 ok. >10/>10ok >10/>10ok >10/>10ok >iO/>wok >10/>10ok >10/>10ok >10/>10ok >10/>10ok STONE RETAINING WAU SYSTEMS RETAINING WALL DESIGN Version Version 1 0 2 Build 126 SEISMIC DESIGN Project ALL CATS HOSPITAL Project No 272-020 Case. WALL #1 Design Method: Rankme-w/Batter (modified soil interface) Date 08/31/2006 /fA/f Design Parameters Soil Parameters' Reinforced Fill Retained Zone Foundation Soil Reinforced Fill Type Unit Fill f c g pcf 31 0 126 31 0 126 34 0 113 Silts & sands Crushed Stone, 1 inch minus Peak Acceleration = 0 15 g Vertical Acceleration = 000g Factors of Safety (seismic are 75% of static) sliding 150/1 13 pullout 150/1 13 uncertainties overturning 2 00/150 shear 150 connection bearing 2 00/150 bending 150 1 50/1 13 1 50/1 13 Reinforcing Parameters Mirafi XTc Geognds Tult RFcr RFd RFid 7XTc 5700 1 60 1 10 1 05 3XTc 3150 160 1 10 105 LTDS 3084 1705 FS 1 50 1 50 2056 1136 080 080 Cds 080 080 Analysis Unit Type Leveling Pad Wall Ht BackSlope Surcharge Compacll Crushed Stone 2558ft 2660deg slope, LL 250 psf uniform surcharge Load Width 10000ft Case: Case 27 Wall Batter 0 00 deg embedment 388ft 1000 ft long DL 0 psf uniform surcharge Load Width 10000ft Results.Sliding Overturning Factors of Safety 1 54/1 52 2 68/2 04 Calculated Bearing Pressure 5528/7509 psf Eccentricity at base 2 91 ft/4 52 ft Reinforcing (ft & Ibs/ft) Calc Bearing 7 44/4 49 Layer 16 15 14 13 12 11 10 9 8 1 6 5 4 3 2 1 Height 2400 2200 2000 1800 1600 1400 1200 1067 933 800 667 533 400 267 1 33 067 Length 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 Tension 205/332 427/572 701/885 934/1142 1151/1390 1357/1630 1274/1589 1117/1472 1198/1576 1276/1670 1358/1790 1435/1892 1512/1994 1587/2094 1239/1789 1281 / 1843 Reinf Type 3XTc 3XTc 3XTc 3XTc 7XTc 7XTc 7XTc 7XTc 7XTc 7XTc 7XTc 7XTc 7XTc 7XTc 7XTc 7XTc Allow Ten !§! 1136/1939 ok 1136/1939 ok 1136/1939 ok 1136/1939 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok Shear 207/206 Pk Conn Tel 595/794 ok 791/1055 ok 988/1317 ok 1184/1578 ok 1320/1760 ok 1447/1929 ok 1573/2097 ok 1657/2209 ok 1741/2322 ok 1826/2434 ok 1910/2546 ok 1994/2659 ok 2031/2708 ok 2031/2708 ok 2031/2708 ok 2031/2708 ok Bending 233/1 75 Serv Conn Tsc N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Pullout El >10/6 44 ok >10/6 51 ok > 10/6 50 ok >10/719ok >10/8 00 ok >10/8 86 ok >10/>10ok >10/>10ok >10/>10ok >10/>10ok >10/>10ok >10/>10ok >10/>10ok >10/>10ok >10/>10ok >10/>10ok STONE RETAINING WALL SYSTEMS RETAINING WALL DESIGN Version Version 1 0 2 Build 126 SEISMIC DESIGN Project ALL CATS HOSPITAL Project No- 272-020 Case WALL#1 Design Method Rankine-w/Batter (modified soil interface) Design Parameters Soil Parameters. Reinforced Fill Retained Zone Foundation Soil Reinforced Fill Type Unit Fill f c g_pcf 31 0 126 31 0 126 34 0 113 Silts & sands Crushed Stone, 1 inch minus Peak Acceleration = 015g Vertical Acceleration = 000g Factors of Safety (seismic are 75% of static) sliding 150/1 13 pullout 150/1 13 uncertainties overturning 2 00/150 shear 150 connection bearing 2 00/150 bending 150 1 50/1 13 1 50/1 13 Reinforcing Parameters Mirafi XTc Geogrtds Tult RFcr RFd RFid LTDS 7XTc 5700 1 60 1 10 1 05 3084 3XTc 3150 160 1 10 105 1705 FS 1 50 1 50 2056 1136 Cj Cds 080 080 080 080 Analysis Unit Type Compacll Leveling Pad Crushed Stone Wall Ht 23 58 ft BackSlope 2660deg slope, Surcharge LL 250 psf uniform surcharge Load Width 10000ft Case- Case 29 Wall Batter OOOdeg embedment 4 69 ft 1000 ft long DL 0 psf uniform surcharge Load Width 10000ft Results-Sliding Overturning Factors of Safety 1 54/1 53 2 70/2 09 Calculated Bearing Pressure 5088/6828 psf Eccentricity at base 2 71 ft/4 18 ft Reinforcing (ft & Ibs/ft) Calc Bearing 8 35/5 22 Layer 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Height 2200 2000 1800 1600 1400 1200 1000 867 733 600 467 333 200 067 Length 170 170 170 170 170 170 170 170 170 170 170 170 170 170 Tension 205/343 426/585 688/878 932/1159 1148/1408 1353/1649 1270/1612 1114/1496 1194/1602 1272/1705 1353/1817 1430/1921 1506/2023 1581/2126 Remf Type 3X7c 3X7c 3XTc 3XTc 7XTc 7XTc 7XTc 7XTc 7XTc 7XTc 7XTc 7XTc 7XTc 7XTc Allow Ten la] 1136/1'939 ok 1136/1939 ok 1136/1939 ok 1136/1939 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok Shear 207/206 Pk Conn Jcl 595/794 ok 791/1055 ok 988/1317 ok 1184/1578 ok 1320/1760 ok 1447/1929 ok 1573/2097 ok 1657/2209 ok 1741/2322 ok / 826/2434 ok 1910/2546 ok 1994/2659 ok 2031/2708 ok 2031/2708 ok Bending 234/1 74 Serv Conn Tsc N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Pullout El >10/6 46 ok >10/6 54 ok >10/6 70 ok >10/7 22 ok >10/8 01 ok >10/8 83 ok >10/>10ok >10/>10ok >10/>10ok >10/>10ok >10/>10ok >10/>10ok >10/>10ok >10/>10ok STONE RETAINING WALL SYSTEMS RETAINING WALL DESIGN Version Version 1 0 2 Build 126 SEISMIC DESIGN Project ALL CATS HOSPITAL Date 08/31/2006 Project No- 272-020 Desjj Case WALL#1 ^^ Design Method L Rankine-w/Batter (modified soil interface) B ,, Design Parameters Soil Parameters f c q pcf '•- / D^ui-iV^-iflj-tj-u-j Ci// o-* n -f o/i .. -. J t -r\eintoiceci rill Jl u 120 j/ Retained Zone -<1 V 126 * Fnvnciation S^il %4 <'> 11$ '/' ~ Reinforced Fill Type Hilts & sands ; / Unit Fill Crushed Stone, 1 inch minus Peak Acceleration = 0 15 g Vertical Acceleration = 0 00 g Factors of Safety (seismic are 75% of static) sliding 1 50/1 13 pullout 1 50/1 13 uncertainties 1 50/1 13 overturning 2 00/1 50 shear 1 50 connection 1 50/1 13 bearing 2 00/1 50 bending 1 50 Reinforcing Parameters Mirafi XTc Geogrids Tult RFcr RFd RFid LTDS FS Tal Ci Cds 7XTc 5700 1 60 1 10 1 05 3084 1 50 2056 080 080 3XTc 3150 160 110 105 1705 150 1136 080 080 \i kttl tyf/vjfvf "7/1 ^/ n }?{/ 11// jo / o 8 7 f, Analysis Case. Case 30 Unit Type Compacll Wall Batter 0 00 deg Leveling Pad Crushed Stone Wall Ht 21 58 ft embedment 5 26 ft BackSlope 26 60 deg slope, 1000 ft long Surcharge LL 250 psf uniform surcharge DL 0 psf uniform surcharge Load Width 10000ft Load Width 10000ft Results Sliding Overturning Bearing Shear Bending Factors of Safety 1 54/1 54 2 72/2 14 9 25/5 97 2 08 12 07 2 34 /1 72 Calculated Bearing Pressure 4649/6159 psf Eccentricity at base 2 50 ft/3 85 ft Reinforcing (ft & Ibs/ft) Calc Allow Ten Pk Conn Serv Conn Put Layer Height Length Tension Remf Type Tal Tel Tsc F 13 2000 160 205/341 3XTc 11 36/1 939 ok 595/794 ok 12 1800 160 426/581 3XTc 11 36/1 939 ok 791/1 055 ok 11 1600 160 687/870 3XTc 1136/1939 ok 988/1317 ok 10 1400 160 929/1148 3XTc 11 36/1 939 ok 11 84/1 578 ok 9 1200 160 1144/1394 7XTc 2056/3509 ok 1320/1 760 ok 8 1000 160 1348/1632 7XTc 2056/3509 ok 1447/1929 ok 7 800 160 1266/1593 7XTc 2056/3509 ok 1573/2097 ok 6 667 160 1109/1476 7XTc 2056/3509 ok 1657/2209 ok 5 533 160 1189/1579 7XTc 2056/3509 ok 1741/2322 ok 4 400 160 1267/1681 7XTc 2056/3509 ok 132b/2434ok 3 267 160 1347/1791 7XTc 2056/3509 ok 1910/2546 ok 2 1 33 160 1061 / 1544 7XTc 2056/3509 ok 1994/2659 ok 1 067 160 1104/1600 7XTc 2056/3509 ok 2031/2708 ok N/A >10/6 N/A >10/6 N/A >10/6 N/A >10/7 N/A >10/6 N/A >10/8 N/A >10/ N/A >10/ N/A >10/ N/A >10/ N/A >10/ N/A >10/ N/A >10/ Reinforcing Quantities (no waste included) 7XTc 1600sy/ft 3XTc 711sy/ft STONE RETAINING WALL SYSTEMS RETAINING WALL DESIGN Version Version 1 0 2 Build 126 SEISMIC DESIGN Project. ALL CATS HOSPITAL Project No 272-020 Case- WALL #1 Design Method Rankme-w/Batter (modified soil interface) Date- 08/31/2006 Designer. MWM- Design Parameters Soil Parameters Reinforced Fill Retained Zone Foundation Soil Reinforced Fill Type: Unit Fill f 31 31 34 Silts & sands Crushed Stone, 1 inch minus c 0 0 0 9 pcf 126 126 •M 9/ /O • r^fii = A 10 // 0 // p : ff I : // : //• // q • /' * = / ^ Peak Acceleration = 0 15 g Vertical Acceleration = 0 00 g Factors of Safety (seismic are 75% of sfaficj sliding 150/1 13 pullout 1 50/1 13 uncertainties overturning 2 00/150 shear 1 50 connection bearing 2 00/150 bending 1 50 Reinforcing Parameters- Mirafi XTc Geognds Tult RFcr RFd 7XTc 5700 1 60 1 10 3XTc 3150 1 60 1 10 1 50/1 13 1 50/1 13 RFid 1 05 105 LTDS 3084 1705 FS 1 50 1 50 Tal 2056 1136 Ci 080 080 Cds 080 080 Analysis Unit Type Compacll Leveling Pad Crushed Stone Wall Ht 1894 ft BackSlope 26 60 deg slope, Surcharge LL 250 psf uniform surcharge Load Width 10000ft Case Case 32 Wall Batter 0 00 deg embedment 5 57 ft 1000 ft long DL 0 psf uniform surcharge Load Width 10000ft Results-Sliding Factors of Safety 1 52/1 53 Calculated Bearing Pressure 4125/5432 psf Eccentricity at base 2 29 ft/3 48 ft Reinforcing (ft & Ibs/ft) Calc Tension 207/348 427/587 687/877 928/1154 1141/1400 1342/1637 1260/1599 1104/1483 1183/1587 938/1381 980/1437 Reinforcing Quantities (no waste included) 7XTc 11 28sy/ft 3XTc 644sy/ft Height 7733 7533 7333 7733 933 733 533 400 267 733 067 Overturning Bearing 267/217 psf Remf Type 3XTc 3XTc 3XTc 3XTc 7XTc 7XTc 7XTc 7XTc 7XTc 7XTc 7XTc 10 08/6 63 Allow Ten Tal 11 36/1 939 ok 11 36/1 939 ok 11 36/1939 ok 11 36/1 939 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok Shear 209/208 Pk Conn J_cl 598/797 ok 794/1058 ok 990/1320 ok 1186/1581 ok 1322/1 762 ok 1448/1931 ok 1574/2099 ok 1659/2211 ok 7743/2324 ok 1827/24Jb ok 1869/2492 ok Bending 229/1 66 Serv Conn Tsc N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Pullout £S >70/6 65 ok >10/6 73 ok >10/6 84 ok >10/7 29 ok >10/801 ok >10/8 78 ok >10/>10ok >10/>10ok >10/>IQok >10/>10ok STONE RETAINING WALL SYSTEMS RETAINING WALL DESIGN Version Version 102 Build 126 SEISMIC DESIGN Project ALL CATS HOSPITAL Project No 272-020 Case WALL#1 Design Method Rankme-w/Batter (modified soil interface) Date 08/31/2006^ Desic Design Parameters Soil Parameters Reinforced Fill Retained Zone Foundation Soil Reinforced Fill Type Unit Fill f c g pcf 31 0 126 31 0 126 34 0 113 Silts & sands Crushed Stone, 1 inch minus 8 1 6 5 4 3 2 Peak Acceleration = 0 15 g Vertical Acceleration = 0 00 g Factors of Safety (seismic are 75% of static) sliding 150/1 13 pullout 150/1 13 uncertainties overturning 2 00/150 shear 150 connection bearing 2 00/1 50 bending 150 1 50/1 13 1 50/1 13 Reinforcing Parameters Mirafi XTc Geognds Tult RFcr RFd RFid 7XTc 5700 1 60 1 10 1 05 3XTc 3150 1 60 1 10 1 05 LTDS 3084 1705 FS 1 50 1 50 2056 1136 Qi 080 080 Cds 080 080 Analysis. Unit Type Compacll Leveling Pad Crushed Stone WallHt 1725ft BackSlope 2660deg slope, Surcharge LL 250 psf uniform surcharge Load Width 10000ft Case: Case 33 Wall Batter 0 00 deg embedment 500ft 7000 ft long DL 0 psf uniform surcharge Load Width 10000ft Results Sliding Factors of Safety 1 56/1 58 Calculated Bearing Pressure 3664/4652 psf Eccentricity at base 2 04 ft/3 10 ft Reinforcing (ft & Ibs/ft) Length 140 140 140 140 140 140 140 140 140 140 Reinforcing Quantities (no waste included) 7XTc 778sy/ft 3XTc 778sy/ft Overturning 2 82/2 35 Bearing 10 82/7 47 Shear 207/206 Bending 278/254 Layer 10 9 8 7 6 5 4 3 2 1 Height 7600 7533 7333 7733 933 733 533 333 200 067 Calc Tension 76/228 182/349 478/671 731 / 955 956/1208 1166/1452 1365/1688 1277/1645 1116/1526 1195/1629 Remf Type 3XTc 3XTc 3XTc 3XTc 3XTc 7XTc 7XTc 7XTc 7XTc 7XTc Allow Ten Tal 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok Pk Conn Tel 562/750 ok 628/837 ok 824/1098 ok 1020/1360 ok 1216/1622 ok 1341/1 788 ok 1467/1 956 ok 1594/2125 ok 1678/2237 ok 1762/2350 ok Serv Conn Tsc N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Pullout E§ >10/>10ok >10/8 12 ok >10/6 85 ok >10/7 05 ok >1 0/7 65 ok >10/8 36 ok >10/9 12 ok >10/>10ok >10/>10ok >10/>1UCK STONE RETAINING WALL SYSTEMS RETAINING WALL DESIGN Version Version 102 Build 126 SEISMIC DESIGN Project ALL CATS HOSPITAL Project No 272-020 Case WALL#1 Design Method Rankme-w/Batter (modified soil interface) Date. Desi Design Parameters Soil Parameters. Reinforced Fill Retained Zone Foundation Soil Reinforced Fill Type Unit Fill ! c g pcf 31 0 126 31 0 126 34 0 113 Silts & sands Crushed Stone, 1 inch minus Peak Acceleration = 0 15 g Vertical Acceleration = 000g Factors of Safety (seismic are 75% of static) sliding 150/1 13 pullout 150/1 13 uncertainties overturning 2 00/150 shear 150 connection bearing 2 00/150 bending 1 50 Reinforcing Parameters Mirafi XTc Geogrids Tult RFcr RFd RFid LTDS FS 7XTc 5700 1 60 1 10 105 3084 1 50 3XTc 3150 1 60 1 10 105 1705 1 50 1 50/1 13 1 50/1 13 Tal 2056 1136 Ci 080 080 Cds 080 080 Analysis Unit Type Leveling Pad Wall Ht BackSlope Surcharge Compacll Crushed Stone 1343ft 2660deg slope, LL 250 psf uniform surcharge Load Width 10000ft Case Case 36 Wall Batter 0 00 deg embedment 418ft 1000 ft long DL 0 psf uniform surcharge Load Width 10000ft Results:Sliding Overturning Factors of Safety 1 54/1 62 2 81/2 59 Calculated Bearing Pressure 2884/3485 psf Eccentricity at base 1 75 ft/2 48 ft Reinforcing (ft & Ibs/ft) Calc Tension 94/247 795/355 497/675 745/950 964/7194 7769/7429 888/7204 779/7055 Reinforcing Quantities (no waste included) 7XTc 400sy/ft 3XTc 667sy/ft Bearing 11 66/867 Shear 229/227 Bending 2 81 /1 94 Layer 8 7 6 5 4 3 2 1 Height 7200 7733 933 733 533 333 733 067 Reinf Type 3XTc 3XTc 3XTc 3XTc 3XTc 7XTc 7XTc 7XTc Allow Ten Tal 7 7 36/7 939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok Pk Conn Tel 587/774 ok 646/861 ok 842/1 123 ok 1038/1385 ok 1235/1 646 ok 1353/1804 ok 1479/1972 ok 1521/2028 ok Serv Conn Tsc N/A N/A N/A N/A N/A N/A N/A N/A Pullout ES >10/>10ok > 10/8 30 ok >10/6 90 ok >10/709ok >10/7 70 ok >10/8 42 ok >10/>10ok >10/>10ok STONE RETAINING IWU. SYSTEMS RETAINING WALL DESIGN Version Version 1 0 2 Build 126 SEISMIC DESIGN Project ALL CATS HOSPITAL Project No- 272-020 Case- WALL #1 Design Method' Rankme-w/Batter (modified soil interface) Date 08/3 Desi Design Parameters Soil Parameters: Reinforced Fill Retained Zone Foundation Soil Reinforced Fill Type Unit Fill f c g pcf 31 0 126 31 0 126 34 0 113 Silts & sands Crushed Stone, 1 inch minus Peak Acceleration = 0 15 g Vertical Acceleration = 000g Factors of Safety (seismic are 75% of static) sliding 150/1 13 pullout 150/1 13 uncertainties overturning 2 00/150 shear 150 connection bearing 2 00/150 bending 150 1 50/1 13 1 50/1 13 Reinforcing Parameters Mirafi XTc Geognds Tult RJFcr RFd RFid 7XTc 5700 160 1 10 1 05 3XTc 3150 1 60 1 10 105 LTDS 3084 1705 FS 1 50 1 50 Tal 2056 1136 080 080 Cds 080 080 Analysis Unit Type Compacll Leveling Pad Crushed Stone WallHt 1145ft BackSlope 2660deg slope, Surcharge LL 250 psf uniform surcharge Load Width 10000ft Case- Case 37 Wall Batter OOOdeg embedment 3 74 ft 1000 ft long DL 0 psf uniform surcharge Load Width 10000ft Results Sliding Overturning Factors of Safety 1 54/1 65 2 80/2 79 Calculated Bearing Pressure 2482/2908 psf Eccentricity at base 1 63 ft/2 20 ft Reinforcing (ft & Ibs/ft) Calc Tension 95/232 195/344 496/659 741/928 957/1165 751 /1007 618/889 Reinforcing Quantities (no waste included) 7XTc 244sy/ft 3XTc 611 sy/ft Bearing 1225/955 Shear 2 61/2 59 Bending 284/1 87 Layer 7 6 5 4 3 2 1 Height 1000 933 733 533 333 1 33 067 Reinf Type 3XTc 3XTc 3XTc 3XTc 3XTc 7XTc 7XTc Allow Ten Tal 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 2056/3509 ok 2056/3509 ok Pk Conn Tel 582/776 ok 648/863 ok 844/1 125 ok 1040/1 387 ok 1236/1648 ok 1354/1805 ok 1396/1861 ok Serv Conn Tsc N/A N/A N/A N/A N/A N/A N/A Pullout FS >10/>10ok >10/8 38 ok >10/6 91 ok >10/712ok >10/7 75 ok >10/>10ok >10/>10ok TONE RETAINING WALL SYSTEMS RETAINING WALL DESIGN Version Version 1 0 2 Build 126 SEISMIC DESIGN Project ALL CATS HOSPITAL Project No 272-020 Case WALL#1 Design Method, Rankine-w/Batter (modified soil interface) Design Parameters Soil Parameters' Reinforced Fill Retained Zone Foundation Soil Reinforced Fill Type Unit Fill f £ 31 0 31 0 34 0 Silts & sands Crushed Stone, 1 inch minus OOOg g pcf 126 126 113 Peak Acceleration = 0 15 g Vertical Acceleration Factors of Safety (seismic are 75% of static) sliding 150/1 13 pullout 150/1 13 uncertainties overturning 2 00/150 shear 150 connection bearing 2 00/150 bending 150 1 50/1 13 1 50/1 13 Reinforcing Parameters Mirafi XTc Geogrids Tult RFcr RFd RFid LTDS FS Tal Ci 3XTc 3150 160 110 105 1705 150 1136 080 Cds 080 Analysis Unit Type Compacll Leveling Pad Crushed Stone Wall Ht 10 14 ft BackSlope 2660deg slope, Surcharge LL 250 psf unifot m surcharge Load Width 10000ft Case- Case 38 Wall Batter 0 00 deg embedment 2 97 ft 1000 ft long DL 0 psf uniform surcharge Load Width 10000ft Results-Sliding Overturning Factors of Safety 1 50/1 61 2 59/2 69 Calculated Bearing Pressure 2306/2729 psf Eccentricity at base 1 61 ft/2 10 ft Reinforcing (ft & Ibs/ft) Calc. Tension 97/226 796/338 496/657 738/929 779/7006 725/983 Reinforcing Quantities (no waste included) 3XTc 633sy/ft Bearing 10 60/8 14 Shear 309/307 Bending 279/1 79 Layer 6 5 4 3 2 1 Height 867 800 600 400 200 067 Reinf Type 3XTc 3XTc 3XTc 3XTc 3XTc 3XTc Allow Ten Tal 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1939 ok 11 36/1 939 ok Pk Conn Tel 585/779 ok 650/867 ok 846/1 128 ok 1042/1390 ok 1238/1651 ok 1266/1 688 ok Serv Conn Tsc N/A N/A N/A N/A N/A N/A Pullout >7 0/7 45 ok >10/6 15 ok 8 87/5 36 ok 9 04/5 75 ok >1 0/7 49 ok >10/937ok STONE RETAINING WALL SYSTEMS RETAINING WALL DESIGN Version Version 1 0 2 Build 126 SEISMIC DESIGN Project- ALL CATS HOSPITAL Project No 272-020 Case- WALL #1 Design Method Rankine-w/Batter (modified soil interface) Date 08/3, Desi Design Parameters Soil Parameters Reinforced Fill Retained Zone Foundation Soil Reinforced Fill Type Unit Fill f c g pcf 31 0 126 31 0 126 34 0 113 Silts & sands Crushed Stone, 1 inch minus Peak Acceleration = 0 15 g Vertical Acceleration = 000g Factors of Safety (seismic are 75% of static) sliding 150/1 13 pullout 150/1 13 uncertainties overturning 2 00/150 shear 150 connection bearing 2 00/150 bending 150 1 50/1 13 1 50/1 13 Reinforcing Parameters Mirafi XTc Geogrids Tult RFcr RJFd RFid LTDS FS 3XTc 3150 1 60 1 10 1 05 1705 1 50 Analysis. Unit Type Leveling Pad Wall Ht BackSlope Surcharge Compacll Crushed Stone 888ft 26 60 deg slope, LL 250 psf uniform surcharge Load Width 10000ff 1st 1136 Ql 080 Cds 080 Case- Case 40 Wall Batter 0 00 deg embedment 378ft 1000 ft long DL 0 psf uniform surcharge Load Width 10000ft Results. Sliding Overturning Factors of Safety 1 53/1 52 2 54/2 51 Calculated Bearing Pressure 2034/2474 psf Eccentricity at base 1 33 ft/1 80 ft Reinforcing (ft & Ibs/ft) Calc Tension 704/227 200/339 502/666 740/943 778/7025 Reinforcing Quantities (no waste included) 3XTc 444sy/ft Bearing 12 26/9 20 Shear 310/308 Bending 255/1 61 Reinf Type 3XTc 3XTc 3XTc 3XTc 3XTc Allow Ten Tal 11 36/1 939 ok 11 36/1 939 ok 1 136/1 939 ok 11 36/1 939 ok 11 36/1 939 ok Pk Conn Tel 592/789 ok 657/876 ok 853/11 38 ok 1050/1399 ok 1246/1661 ok Serv Conn Tsc N/A N/A N/A N/A N/A Pullout FS > 10/5 28 ok 9 60/4 53 ok 6 98/4 20 ok 7 50/4 71 ok >10/6 30 ok STONE RETAINING WALL SYSTEMS RETAINING WALL DESIGN Version Version 1 0 2 Build 126 SEISMIC DESIGN Project ALL CATS HOSPITAL Project No- 272-020 Case. WALL #1 Design Method: Rankine-w/Batter (modified soil interface) Date Design Parameters Soil Parameters Reinforced Fill Retained Zone Foundation Soil Reinforced Fill Type Unit Fill f c g pcf 31 0 126 31 0 126 34 0 113 Silts & sands Crushed Stone, 1 inch minus Peak Acceleration * 0 15 g Vertical Acceleration = 0 00 g Factors of Safety (seismic are 75% of static) sliding 150/1 13 pullout 150/1 13 uncertainties overturning 2 00/150 shear 150 connection bearing 2 00/150 bending 150 Reinforcing Parameters1 Mirafi XTc Geognds 3XTc 1 50/1 13 1 50/1 13 Analysis- Tult 3150 Unit Type Leveling Pad WallHt BackSlope Surcharge RFct RFd RFid LTDS FS 1 60 1 10 1 05 1705 1 50 Compacll Crushed Stone 1024ft 2660deg slope, LL 250 psf uniform surcharge Load Width 10000ft Tal Ci Cds 1136 080 080 Case Case 41 Wall Batter 0 00 deg embedment 6 13 ft 1000 ft long DL 0 psf uniform surcharge Load Width 10000ft Results Sliding Overturning Factors of Safety 1 54/1 65 2 72/2 81 Calculated Bearing Pressure 2276/2670 psf Eccentricity at base 1 62 ft/2 12 ft Reinforcing (ft & Ibs/ft) Calc Tension 109/246 204/355 509/673 750/942 788/1014 732/988 Reinforcing Quantities (no waste included) 3XTc 6 67 sy/ft Bearing 15 85/12 64 Shear 306/304 Bending 243/1 59 Layer 6 5 4 3 2 1 Height 867 800 600 400 200 067 Remf. Type 3XTc 3XTc 3XTc 3XTc 3XTc 3XTc Allow Ten Taj 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok Pk Conn TcJ 595/793 ok 660/880 ok 856/1 142 ok 1053/1403 ok 1249/1665 ok 1267/1 690 ok Serv Conn Tsc N/A N/A N/A N/A N/A N/A Pullout FS >10/8 16 ok >10/6 88 ok 9 81/5 93 ok 9 86/6 28 ok >10/811 ok >10/>10ok STONE RETAINING WALL SYSTEMS RETAINING WALL DESIGN Version Version 1 0 2 Build 126 SEISMIC DESIGN Project ALL CATS HOSPITAL Project No 272-020 Case: WALL #1 Design Method Rankme-w/Batter (modified soil interface) Date 08/i Design Parameters Soil Parameters Reinforced Fill Retained Zone Foundation Soil Reinforced Fill Type Unit Fill f c g pcf 31 0 126 31 0 126 34 0 113 Silts & sands Crushed Stone, 1 inch minus Peak Acceleration = 0 15 g Vertical Acceleration = 0 00 g Factors of Safety (seismic are 75% of static) sliding 150/1 13 pullout 150/1 13 uncertainties overturning 2 00/150 shear 150 connection bearing 2 00/150 bending 150 1 50/1 13 1 50/1 13 Reinforcing Parameters. Mirafi XTc Geogrids 7XTc 3XTc Tult 5700 3150 RFcr 1 60 1 60 RFd 1 10 1 10 RFid 1 05 1 05 LTDS 3084 1705 FS 1 50 1 50 Tal 2056 1136 Ci 080 080 Cds 080 080 Analysis. Unit Type Compacll Leveling Pad Crushed Stone Wall Ht 12 27 ft BackSlope 2660deg slope, Surcharge LL 250 psf uniform surcharge Load Width 10000ft Case Case 42 Wall Batter OOOdeg embedment 5 18 ft 1000 ft long DL 0 psf uniform surcharge Load Width 10000ft Results Bearing 13 82/10 76 Sliding Overturning Factors of Safety 1 55/1 65 2 86/2 75 Calculated Bearing Pressure 2625/3101 psf Eccentricity at base 1 65 ft/2 27 ft Reinforcing (ft & Ibs/ft) Calc Allow Ten Tension Reinf. Type Tal 113/268 3XTc 1136/1939 ok 208/377 3XTc 1136/1939 ok 515/699 3XTc 1136/1939 ok 760/973 3XTc 1136/1939 ok 976 /1214 3XTc 1136/1939 ok 969/1248 7XTc 2056/3509 ok 873 /1186 7XTc 2056/3509 ok Reinforcing Quantities (no waste included) 7XTc 256sy/ft 3XTc GSQsy'/ft Layer 7 6 5 4 3 2 1 Height 1067 1000 800 600 400 200 067 Length 11 5 11 5 11 5 11 5 11 5 11 5 11 5 Shear 257/256 Pk Conn Tel 597/796 ok 663/884 ok 859/1145 ok 1055/1407 ok 1251/1668 ok 1364/1818 ok 1448/1930 ok Bending 233/1 58 Serv Conn Tsc N/A N/A N/A N/A N/A N/A N/A Pullout E§ >10/9 71 ok >10/8 21 ok >10/6 91 ok >10/7 14 ok >10/777ok >10/9 84 ok >10/>10ok STONE RETAINING WALL SYSTEMS RETAINING WALL DESIGN Version Version 1 0 2 Build 126 SEISMIC DESIGN Project. ALL CATS HOSPITAL Project No 272-020 Case: WALL #1 Design Method Rankme-w/Batter (modified soil interface) Date Design Parameters Soil Parameters Reinforced Fill Retained Zone Foundation Soil Reinforced Fill Type Unit Fill f c g pcf 31 0 126 31 0 126 34 0 113 Silts & sands Crushed Stone, 1 inch minus Peak Acceleration = 0 15 g Vertical Acceleration = 0 00 g Factors of Safety (seismic are 75% of static) sliding 150/1 13 pullout 150/1 13 uncertainties overturning 2 00/150 shear 150 connection bearing 2 00/1 50 bending 150 1 50/1 13 1 50/1 13 Reinforcing Parameters Mirafi XTc 7XTc 3XTc Tult 5700 3150 RFcr 1 60 1 60 Geognds RFd 1 10 1 10 RFid 1 05 1 05 LTDS 3084 1705 FS 1 50 1 50 Tal 2056 1136 Ci 080 080 Cds 080 080 Analysis Unit Type Compacll Leveling Pad Crushed Stone Wall Ht 1429 ft BackSlope 2660deg slope, Surcharge LL 250 psf uniform surcharge Load Width 10000ft Case Case 43 Wall Batter 0 00 deg embedment 4 15ft 1000 ft long DL 0 psf uniform surcharge Load Width 10000ft Results.Sliding Overturning Factors of Safety 1 55/1 62 2 84/2 55 Calculated Bearing Pressure 3046/3716 psf Eccentricity at base 1 79 ft/2 60 ft Reinforcing (ft & Ibs/ft) Calc Tension 776/282 272/397 527 / 778 768/998 986/7246 7797/7485 7742/7485 7004/7387 Bearing 11 32/828 Layer 8 7 6 5 4 3 2 7 Height 7267 1200 1000 800 600 400 200 067 Length 725 725 725 725 725 725 725 725 Remf Type 3XTc 3XTc 3XTc 3XTc 3XTc 7XTc 7XTc 7XTc Allow Ten lal 1136/1939 ok 1136/1939 ok 1136/1939 ok 1136/1939 ok 1136/1939 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok Shear 226/224 Pk Conn l£t 600/800 ok 665/887 ok 861/1148 ok 1057/1410 ok 1254/1672 ok 1365/1820 ok 1491/1989 ok 1576/2101 ok Bending 225/1 57 Serv Conn Tsc N/A N/A N/A N/A N/A N/A N/A N/A Pullout F_S >70/9 43 ok >10/8 08 ok >10/687ok > 10/7 09 ok >10/7 71 ok >70/8 <*2 ok >10/>10ok >10/>10ok Reinforcing Quantities (no waste included) 7XTc 417sy/ft 3XTc 694sy/ft STONE RETAINING WALL SYSTEMS RETAINING WALL DESIGN Version Version 1 0 2 Build 126 SEISMIC DESIGN Project. ALL CATS HOSPITAL Project No- 272-020 Case- WALL #1 Design Method Rankme-w/Batter (modified soil interface) Date. Design Parameters Soil Parameters. Reinforced Fill Retained Zone Foundation Soil Reinforced Fill Type Unit Fill f c a pcf 31 0 126 31 0 126 34 0 113 Silts & sands Crushed Stone, 1 inch minus Peak Acceleration = 015g Vertical Acceleration = 000g Factors of Safety (seismic are 75% of static) sliding 150/1 13 pullout 150/1 13 uncertainties overturning 2 00/150 shear 150 connection bearing 2 00/150 bending 150 1 50/1 13 1 50/1 13 Reinforcing 7XTc 3XTc Parameters Mirafi XTc Geognds Tult 5700 3150 RFcr 1 60 1 60 RFd 1 10 1 10 RFid 1 05 1 05 LTDS 3084 1705 FS 1 50 1 50 Tal 2056 1136 Ci 080 080 Cds 080 080 Analysis Unit Type Compacll Leveling Pad Crushed Stone WallHt 1365ft BackSlope 26 60 deg slope, Surcharge LL 250 psf uniform surcharge Load Width 10000ft Case. Case 44 Wall Batter 000 deg embedment 2 53 ft 1000 ft long DL 0 psf uniform surcharge Load Width 10000ft Results.Sliding Overturning Factors of Safety 1 53/1 60 2 75/2 52 Calculated Bearing Pressure 2957/3612 psf Eccentricity at base 1 80 ft/2 56 ft Reinforcing (ft & Ibs/ft) Calc Tension 119/270 213/378 523/702 770/979 986/1223 1191/1459 903/1228 730/1076 Reinforcing Quantities (no waste included) 7XTc 4 00 sy/ft 3XTc 6 67 sy/ft Bearing 9 43/6 74 Shear 226/225 Bending 218/1 52 Remf Type 3XTc 3XTc 3XTc 3XTc 3XTc 7XTc 7XTc 7XTc Allow Ten Tal 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 2056/3509 ok 2056/3509 ok 2056/3509 ok Pk Conn Tel 602/803 ok 668/890 ok 864/1 152 ok 1060/1413 ok 1256/1675 ok 1367/1822 ok 1493/1991 ok 1535/2047 ok Serv Conn Tsc N/A N/A N/A N/A N/A N/A N/A N/A Pullout FS >10/9 46 ok >10/8 06 ok >10/6 81 ok >1 0/7 03 ok >10/7 66 ok >1 0/8 38 ok >10/>10ok >10/>10ok STONE RETAINING WALL SYSTEMS RETAINING WALL DESIGN Version Version 102 Build 126 SEISMIC DESIGN Project ALL CATS HOSPITAL Project No. 272-020 Case- WALL #1 Design Method Rankine-w/Batter (modified soil interface) Design Parameters Soil Parameters' Reinforced Fill Retained Zone Foundation Soil Reinforced Fill Type Unit Fill f c g pcf 31 0 126 31 0 126 34 0 113 Silts & sands Crushed Stone, 1 inch minus p, — j--r -n * ^ = //; //= //= //i/ i 5 4 3 2 I Peak Acceleration = 0 15 g Vertical Acceleration = 0 00 g Factors of Safety (seismic are 75% of static) sliding 150/1 13 pullout 150/1 13 uncertainties overturning 2 00/1 50 shear 150 connection bearing 2 00/150 bending 150 1 50/1 13 1 50/1 13 Reinforcing Parameters Mirafi XTc Geogrids Tult RFcr RFd RFid LTDS FS 7XTc 5700 1 60 1 10 1 05 3084 1 50 3XTc 3150 1 60 1 10 1 05 1705 1 50 Analysis. Unit Type Leveling Pad WallHt BackSlope Surcharge Compacll Crushed Stone 12 35 ft 2660deg slope, LL 250 psf uniform surcharge Load Width 10000ft Tal Ci Cds 2056 080 080 1136 080 080 Case Case 46 Wall Batter 0 00 deg embedment 262ft 1000 ft long DL 0 psf uniform surcharge Load Width 10000ft Results: Sliding Overturning Factors of Safety 1 55/1 64 2 84/2 72 Calculated Bearing Pressure 2650/3140 psf Eccentricity at base 1 66 ft/2 30 ft Reinforcing (ft & Ibs/ft) Calc Tension 122/279 214/385 524 / 708 769/983 984/1224 975/1258 878/1195 Reinforcing Quantities (no waste included) 7XTc 256sy/ft 3X.Tc 639sy/ft Bearing 10 45/7 87 Shear 256/254 Bending 212/1 46 Layer 7 6 5 4 3 2 1 Height 7067 1000 800 600 400 200 067 Remf Type 3XTc 3XTc 3XTc 3XTc 3XTc 7XTc 7XTc Allow Ten Tal 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 2056/3509 ok 2056/3509 ok Pk Conn Tel 605/806 ok 670/894 ok 866/1 155 ok 1063/1 41 7 ok 1257/1676 ok 1368/1 825 ok 1453/1 937 ok Serv Conn Tsc N/A N/A N/A N/A N/A N/A N/A Pullout FS >10/9 45 ok >10/8 13 ok >10/6 88 ok >1 0/7 11 ok >1 0/7 75 ok > 10/9 82 ok >10/>10ok STONE RETAINING WALL SYSTEMS RETAINING WALL DESIGN Version Version 1 0 2 Build 126 SEISMIC DESIGN Project ALL CATS HOSPITAL Project No. 272-020 Case- WALL #1 Design Method Rankme-w/Batter (modified soil interface) Date Desig 08/31. Design Parameters Soil Parameters. Reinforced Fill Retained Zone Foundation Soil Reinforced Fill Type Unit Fill f c g pcf 31 0 126 31 0 126 34 0 113 Silts & sands Crushed Stone, 1 inch minus Peak Acceleration = 0 15 g Vertical Acceleration -OOOg Factors of Safety (seismic are 75% of static) sliding 150/1 13 pullout 150/1 13 uncertainties overturning 2 00/150 shear 150 connection bearing 2 00/150 bending 150 1 50/1 13 1 50/1 13 Reinforcing Parameters. Mirafi XTc Geognds Tult RFcr RFd RFjd 7XTc 5700 1 60 1 10 1 05 3XTc 3150 1 60 1 10 1 05 2056 1136 080 080 Cds 080 080 Analysis Unit Type Leveling Pad Wall Ht BackSlope Surcharge Compacll Crushed Stone 11 04ft 2660deg slope, LL 250 psf uniform surcharge Load Width 10000ft Case- Case 47 Wall Batter OOOdeg embedment 2 71 ft 1000 ft long DL 0 psf uniform surcharge Load Width 10000ft Results Sliding Overturning Factors of Safety 1 51/1 62 2 68/2 70 Calculated Bearing Pressure 2459/2913 psf Eccentricity at base 1 69 ft/2 24 ft Reinforcing (ft & Ibs/ft) Calc Tension 724/282 215/387 524/772 767/987 980/7229 970/7264 Bearing 10 40/7 89 Shear 257/256 Bending 207/1 40 Layer 6 5 4 3 2 1 Height 933 867 667 467 267 067 Length 705 105 705 705 705 105 Remf Type 3XTc 3XTc 3XTc 3XTc 3XTc 7XTc Allow Ten Tal 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 1136/1 939 ok 2056/3509 ok Pk Conn Tel 607/870 ok 673/897 ok 869/1 159 ok 1065/1420 ok 1258/1677 ok 1370/1 827 ok Serv Conn Tsc N/A N/A N/A N/A N/A N/A Pullout FS >70/8 42 ok > 10/7 34 ok >10/6 32 ok >10/6 62 ok >10/7 27 ok >W/9 28 ok Reinforcing Quantities (no waste included) 7XTc 1 17sy/ft 3XTc 583sy/ft STONE RETAINING WALL SYSTEMS RETAINING WALL DESIGN Version Version 1 0 2 Build 126 SEISMIC DESIGN Project ALL CATS HOSPITAL Project No 272-020 Case WALL#1 Design Method. Rankme-w/Batter (modified soil interface) Date. 08/31/2M6 Desigrj0r**Mfy/IM / / A Design Parameters Soil Parameters Reinforced Fill Retained Zone Foundation Soil Reinforced Fill Type Unit Fill f c g pcf 31 0 126 31 0 126 34 0 113 Silts & sands Crushed Stone, 1 inch minus Peak Acceleration = 0 15 g Vertical Acceleration = 0 00 g Factors of Safety (seismic are 75% of static) sliding 150/1 13 pullout 150/1 13 uncertainties overturning 2 00/150 shear 150 connection bearing 2 00/1 50 bending 150 1 50/1 13 1 50/1 13 Reinforcing Parameters Mirafi XTc Geogrids Tult RFcr RFd RFid LTDS FS Ta/ 3XTc 3150 160 110 105 1705 150 1136 Q. 080 Cds 080 Analysis Unit Type Leveling Pad Wall Ht BackSlope Surcharge Compacll Crushed Stone 9 73 ft 2660deg slope, LL 250 psf uniform surcharge Load Width 10000ft Case Case 48 Wall Batter OOOdeg embedment 239ft 1000 ft long DL 0 psf uniform surcharge Load Width 10000ft Results.Sliding Overturning Factors of Safety 1 51/1 60 2 57/2 69 Calculated Bearing Pressure 2218/2600 psf Eccentricity at base 1 52 ft/1 96 ft Reinforcing (ft & Ibs/ft) Calc Tension 726/245 275/348 524/668 763/937 627/846 530/768 Reinforcing Quantities (no waste included) 3XTc 600sy/ft Bearing 9 81/7 59 Shear 303/301 Bending 204/1 35 Layer 6 5 4 3 2 1 Height 800 733 533 333 1 33 067 Remf Type 3XTc 3XTc 3XTc 3XTc 3XTc 3XTc Allow Ten !§! 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1 939 ok 11 36/1939 ok Pk Conn Is! 609/812 ok 675/900 ok 871/1161 ok 1067/1423 ok 1258/1 677 ok 1263/1 684 ok Serv Conn Tsc N/A N/A N/A N/A N/A N/A Pullout FS >1 0/6 68 ok >10/5 83 ok 8 24/5 17 ok 8 61/5 61 ok >1 0/8 79 ok >10/>10ok STONE RETAINING WALL SYSTEMS RETAINING WALL DESIGN Version Version 1 0 2 Build 126 SEISMIC DESIGN Project ALL CATS HOSPITAL Project No 272-020 Case- WALL #1 Design Method Rankme-w/Batter (modified soil interface) Design Parameters Soil Parameters Reinforced Fill Retained Zone Foundation Soil Reinforced Fill Type Unit Fill f c q pcf 31 0 126 31 0 126 34 0 113 Silts & sands Crushed Stone, 1 inch minus Peak Acceleration = 0 15 g Vertical Acceleration = 000g Factors of Safety (seismic are 75% of static) sliding 1 50/1 13 pullout 150/1 13 uncertainties overturning 2 00/150 shear 150 connection bearing 2 00/150 bending 150 1 50/1 13 1 50/1 13 Reinforcing Parameters- MirafiXTc Geogrids 3XTc Analysis Tult 3150 Unit Type Leveling Pad WallHt BackSlope Surcharge RFcr RFd RFid LTDS 1 60 1 10 1 05 1705 Compacil Crushed Stone 841 ft 26 60 deg slope, LL 250 psf uniform surcharge Load Width 10000ft FS 1 50 1136 Qi 080 Cds 080 Case- Case 49 Wall Batter 0 00 deg embedment 206ft 1000 ft long DL 0 psf uniform surchat ge Load Width 10000ft Results Sliding Overturning Factors of Safety 1 55/1 50 2 54/2 50 Calculated Bearing Pressure 1922/2346 psf Eccentricity at base 1 23 ft/1 68 ft Reinforcing (ft & Ibs/ft) Calc. Layer Height Length Tension 727/239 215/342 522/669 617/808 600/822 Bearing 9 66/7 02 Shear 382/379 Bending 2 01 /1 29 5 4 3 2 1 667 600 400 200 067 Remf Type 3XTc 3XTc 3XTc 3XTc 3XTc Allow Ten Tal 11 36/1 939 ok 11 36/1 939 ok 11 36/1939 ok 11 36/1 939 ok 11 36/1 939 ok Pk Conn Tel 61 1/81 5 ok 677/902 ok 873/1 164 ok 1069/1425 ok 1200/1600 ok Serv Conn Tsc N/A N/A N/A N/A N/A Pullout >10/4 78 ok 8 56/4 30 ok 6 50/4 06 ok 8 77/5 36 ok >10/6 83 ok Reinforcing Quantities (no waste included) 3XTc 417sy/ft STONE RETAINING WALL SYSTEMS RETAINING WALL DESIGN Version Version 1 0 2 Build 126 SEISMIC DESIGN Project ALL CATS HOSPITAL Project No 272-020 Case: WALL #1 Design Method. Rankme-w/Batter (modified soil interface) Date- 08/31/2 Desigr Design Parameters Soil Parameters: Reinforced Fill Retained Zone Foundation Soil Reinforced Fill Type Unit Fill. f c g_..pcf 31 0 126 31 0 126 34 0 113 Silts & sands Crushed Stone, 1 inch minus fl /J4 Peak Acceleration = 015g Vertical Acceleration = 000g Factors of Safety (seismic are 75% of static) sliding 150/1 13 pullout 150/1 13 uncertainties overturning 2 00/150 shear 150 connection bearing 2 00/150 bending 150 1 50/1 13 1 50/1 13 Reinforcing Parameters Mirafi XTc Geogrids Tuff RFcr RFd RFid 3XTc 3150 1 60 1 10 1 05 LTDS 1705 fS 750 1136 Ql 080 Cds 080 Analysis- Unit Type Leveling Pad Wall Ht BackSlope Surcharge Compacll Crushed Stone 721ft 2660deg slope, LL 250 psf uniform surcharge Load Width 10000ft Case- Case 50 Wall Batter OOOdeg embedment 1 25 ft 1000 ft long DL 0 psf uniform surcharge Load Width 10000ft Results- Sliding Factors of Safety 1 52/1 43 Calculated Bearing Pressure 7666/2098 psf Eccentricity at base 0 96 ft/1 37 ft Reinforcing (ft & tbs/ft) Layer Height Length 4 600 60 3 467 60 2 267 60 1 067 60 Reinforcing Quantities (no waste included) 3XTc 2 67 sy/ft Overturning 2 46/2 32 Bearing 817/559 Shear 380/377 Bending 292/239 Calc Tension 103/192 263/394 532/697 621/850 Remf Type 3XTc 3XTc 3XTc 3XTc Allow Ten !§! 11 36/1 939 ok 11 36/1 939 Ok 11 36/1 939 ok 11 36/1 939 ok Pk Conn Tel 559/745 ok 690/920 ok 886/1181 ok 1082/1443 ok Serv Conn Tse N/A N/A N/A N/A Pullout El 6 28/2 68 ok 4 85/2 59 ok 4 91/3 00 ok 7 11/4 16 ok Geotechnical Design Parameters accounting 080911 am 09 22 2006 2/4 Request for Soil Parameters Date: Project: Prepared by: Client: 9-22-06 Job No.:0611115 AH Cats Hospital Testing Services Southern California Soil & Testing, Inc. Lynn Yut C/O AH Cats Hospital We have been contracted to design-build a Keystone/geogrid reinforced soil retaining wall for the above referenced project. Please see that attached cross section indicating the reinforced, retained and foundation areas and provide the following soil parameters: Reinforced 31 450 Retained 31 450 Foundation 38 350 126 126 113 Water should be prevented from infiltrating into the reinforced zone behind the wall. Our standard design includes a 4" burrito drain at base of wall. Any other drainage requirements (e.g. drain board, rock column, etc)? Gravel zone behind wall should be wrapped in filter fabric Embedment requirements (distance to daylight)?7' to daylight* Seismic design considerations?Per latest CBC Global design considerations?No Other design considerations?Wall to be compacted fill on compacted formations! soils* Temporary baciccul constraints?1:1 (horizontal to vertical) *due to steepness of slope adjacent to wall in some areas, buried wall depth may be significant Seal of Registered Engineer Company: Southern Caljfo Engineer: Date: Testing. Inc. u •j (] Ll < SOIL & TESTING, INC. Z o fit OVI PHONE (619) 280-4321 TOLL FREE (877) 215-4321 May 17, 2007 FAX(619) 280-4717 San Diego Office PO Box 600627 San Diego, CA 92160-0627 6280 Riverdale Street San Diego, CA 92120 www scst com Indio Office PHONE (760) 775-5983 TOLL FREE(877) 215-4321 FAX(760) 775-8362 83-740 Citrus Avenue Suite G Indio, CA 92201-3438 www scst com SCS&T No. 0611114 Report No. 6 Mr PatO'Day O'Day Consultants 2710 Loker Avenue West Suite 100 Carlsbad, California 92010 Subject RESPONSE TO CITY OF CARLSBAD COMMENTS O'DAY MEDICAL OFFICE BUILDING 2020 CASSIA ROAD CARLSBAD, CALIFORNIA Dear Mr O'Day This letter has been prepared to respond to the comments prepared by the EsGil Corporation, Plan Checker, for the City of Carlsbad The city comments and responses are presented below Comment 6: Provide a copy of the project soil report prepared by a California licensed architect or civil engineer The report shall include foundation design recommendations based on the engineer's findings and shall comply with UBC Section 1804 (include the recommendation for the retaining wall) Responses: , Copies of the project soil reports applicable to the subject project (References 3 and 4) are provided in Appendix I and II Comment 8: Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soil report are properly incorporated into the plans(when required by the soil report) Response 8: The plans, .References 2 and 3, have been reviewed and were found to be in accordance with the recommendations provided in the referenced reports Additionally, slope stability analyses were performed Th«i i.tc ,~,ill have a factor-of-safety gseater than 1 5 in respect to global stability at ii;e completion of the project 3jh_a%ar^y questions regarding this document, please contact me at (619)-280-4321 IA SOIL & TESTING, INC. (6) Addressee, Attn Tim Carroll GBFkv Attachments Appendix I Appendix II - IW Ll O'Day Consultants May 17, 2007 O'Day Medical Office Building SCS&TNo 0611114-6 2020 Cassia Rd, Carlsbad, CA Page 2 REFERENCES / 1 ) "Keystone Retaining Wall Plans For Cassia Professional Offices, All Cats Hospital Keystone Retaining Wall Plans, Sheets 1 to 5", prepared by Red One Engineering, dated December 21, 2006 2 ) 'Temporary Shoring Wall (Adjunct to Keystone RW) For Cassia Professional Offices Plans, Sheets 23 to 25," prepared by PB&A, dated April 30, 2007 3) "Shoring Recommendations, Cassia Professional Offices, 2020 Cassia Road, Carlsbad, California",, prepared by Southern California Soil and Testing, dated February 26, 2007, (SCS&T Job Number 0611114-5) 4 ) "Preliminary Retaining Wall Design Recommendations, All Cats Hospital Testing Services, El Cammo Real and Cassia Road, Carlsbad, California", prepared by Southern California Soil and Testing, Inc , dated September 8, 2006 (SCS&T No 0611115-2) 5 ) "City Comments prepared.-by EsGil Corporation, .Plan Check Number 071296", dated May 14,2007 L.J I I I t; I APPENDIX I i I.I "j 4i I lii "aiU I Ii I I « son * TSSTINO, INC c,ar] Diego Office Indio Office i IJ I <J I I o ST p H o N F-- (619)280-4371 (877) 2.15-4.321 F A X (619) 280-4/17 PO Box 600627 F'HON f. San Diego, CA 92160-0627 (7CO) 775-5983 I O I I F R I 16280 RiverdalP Street (8771 235-^ San Dieqo, CA 92120 www scst com (760) 775-8362 ^ A 8J 710 Citrus AvtTiue Suitf G IndlO, CA 92201 J436 SC com September 8, 2006 SCS&T No. 0611115 Report No. 2 Ms Lynn Yut All Cats Hospital 7O40 Loker Avenue West, Suite 100 Carlsbad, California 92008 Subject- PRELIMINARY RETAINING WALL DESIGN RECOMMENDATIONS ALL CATS HOSPITAL TESTING SERVICES EL CAMINO REAL & CASSIA ROAD CARLSBAD, CALIFORNIA Reference "Geotechnical Investigation, Cassia Road Project'1, prepared by Geocon Incorporated; dated December 16, 2004, (Project No 07431-22-01) Dear Ms Yut In accordance with a request from Mr. Tom Gumn, Southern California Soil and Testing, Inc has prepared this report to provide preliminary retaining wall design recommendations for the masonry retaining walls for the subject project I FOUNDATIONS ( j Conventional shallow foundations may be utilized for the support of the proposed retaining walls The footings should have a minimum depth of 1 8 inches below lowest adjacent finish pad • i grade and a minimum width of 12 inches A bearing capacity of 3000 pounds per square foot LI (psf) may be assumed for said footings. The bearing capacity may be increased by 300 psf and 1 500 psf for each additional foot of foundation width and depth, respectively, up to a maximum of 5000 psf The bearing capacity may be increased by one-third when considering wind and/or seismic forces Footings located adjacent or within slopes should be extended to a depth such •"[ that a minimum horizontal distance of 10 feet exists between the outer footing edge and the Li face of the slope. I | EARTH RETAINING WALLS u Passive Pressure The passive pressure for the prevailing soil conditions may be considered to be 300 psf per foot of depth This pressure may be increased by 1/3 for seismic loading. The coefficient of friction • between concrete and the underlying material may be assumed to be 0 30 When combining " j fnctional and passive resistance, friction should be reduced by 1/s The upper 12 inches of soil should not be considered when calculating passive pressures for exterior walls Ms Lynn Yut September 8. 2006 All Cat's Hospital SCS&TNo 0611115-2 El Cam/no Real and Cassia St, Carlsbad, CA Page 2 Active Pressure The active soil pressure for the design of unrestrained earth retaining structures with level backfills may be assumed to be equivalent to the pressure of a fluid weighing 40 pounds per cubic foot (pcf) This pressure does not consider any surcharge loads. If any are anticipated, this office should be contacted for the necessary increase in soil pressure These values assume a granular and drained backfill condition Waterproofing specifications and details should be provided by the project architect A typical wall subdram detail is provided on Plate No 1 Waterproofing and Subdrain Observation The geotechnical engineer should be requested to verify that waterproofing has been applied and that the subdram has been properly installed However, unless specifically asked to do so, we will not verify proper application of the waterproofing Backfill All backfill soils should be compacted to at least 90 percent relative compaction Expansive or clayey soils should not be used for backfill material The wall should not be backfilled until the grout has reached an adequate strength [Should you have any questions regarding this document or if we may be of further service, r] please contact our office at your convenience , \?ery truly yours, 5%fcv , SOIL & TESTING, INC. I I L. I V. IJ DBAkv _ (2) Addressee 1, I (2) O'Day Consultants, Inc ( J (1) Geogrid Retaining Wall Systems, Inc Attn Forrest Armentrout (fax also) ATTACHMENT Plate No. 1 .€ •ij I.-'1 I L.J I I L.J I I I I •<._ I 18" mto. CompactedFiU crushed " rock,'.2/3 wallheight Typical Retaining Wall Subdrain Detail Not to Scale Miradrain 6000 or equivalent,2/3 wall height <T) Floor Slab (?) Filter Fabric between rock and soil @ Backcut (4) Waterproof back of wall following architect's specifications (5) 4* minimum perforated pipe, SDR35 or equivalent, holes down. 1% fall to outlet, top of pipe below top of slab, encased in 3/4* crushed rock Provide 3 cubic feet per linear foot crushed rock minimum. Crushed rock to be surrounded by filter fabric (Mirafi 140N or equivalent), with 6° mmimum overlap Provide solid outlet pipe at suitable location SC SOUTHERN CALIFORNIA $ SW SOIL & TESTING, INC. ALL CAT'S HOSPITAL BY JOB NUMBER DBA 0611115-2 DATE PLATE NO 9/8/2006 1 APPENDIX II t! ...j < SOU. * TISTINQ, INCi o v X t- o P II O N E (619) 2HO-4321 I" O L L f R F L (877) 21S-4321 FAX (619) 280-4717 San Diego Office PO Box 600627 ban Dieqo, CA '32160-0627 fi^HO PivPirlale Stiect S.in Diego, CA 92120 www scst com p H o N e (760) 775-5983 r O L L I • H L h (H77) 215-4321 TAX (760) 775-8362 Indio Office 83-740 Citrus Avenuf Suite G Indio, CA 92201-34:i8 www scst < om I •. ,. JI *..-I]I 1I uI] February 26,2007 SCS&T No. 0611114 Report No. 5 Mr PatO'Day O'Day Consultants 2710 Loker Avenue West Carlsbad, California 92008 Subject: SHORING RECOMMENDATIONS O'DAY MEDICAL OFFICE BUILDING 2020 CASSIA ROAD CARLSBAD, CALIFORNIA Reference- "Keystone Retaining Wall Plans For Cassia Professional Offices, All Cats Hospital Keystone Retaining Wall Plans, Sheets 1 to 5", prepared by Southern California Soil and Testing, Inc, dated December 21, 2006 Dear Mr. O'Day In accordance with a request from Mr Erik Nelson, of Pacific Building Group this letter has been prepared to provide shoring recommendations for the subject project. We understand improvements will consist of a road widening supported by a Keystone wall and a curb inlet structure. The site is underlain by undocumented fill and formational material commonly identified as the Santiago Formation To determine the extent of the fill along the planned wall alignment SCS&T drilled 3 borings at the locations indicated on Figure 1 The fill was determined to range from approximately 10 to 25 feet in depth thickening to the south and east. The fill consists of soft clays and loose clayey sands. The boring logs are presented in Appendix I. Laboratory testing performed on the sample is presented in Appendix II Shoring along El Cammo Real will be required to support excavations for the construction of the planned wall and curb inlet structure. It is anticipated that soldier beams with tiebacks and lagging will be utilized ranging from about 15 to 27 feet in height starting at wall Station 2+80 and ending at Station 4+00. Areas north and south of the shored area can be cut temporarily at an inclination of 1(H): 1(V) with a 5-foot vertical at the toe of the slope. Cross section A-A', Figure 2, shows the anticipated top and bottom elevation of the shoring along El Camino Real. Typical sections through the most critical areas are shown on Figures 3 and 4 The design parameters to calculate the earth pressures on shoring are presented in Table 1 O'Day Consultants O'Day Medical Office Building 2020 Cassia Rd, Carisbad. CA February 26. 2007 SCS&TNo 0611114-5 Page 2 Table 1 Material Fill Formation Total Unit Weight Pounds Per Cubic Foot 125 135 Internal Friction Angle- Phi 27 35 Cohesion Value Pounds per Square Foot 100 500 IS I iii...)ii An active condition can be applied to shoring that is capable of rotating 0 002 radians. An at- rest condition should be applied to a shoring system that is unyielding and not able to rotate. Construction surcharge loads should be evaluated on a case-by-case basis. Soils should no be stockpiled at the top of slopes or at the top of the shoring. Vertical and lateral movements of the temporary shoring are expected to be small assuming an adequate lateral support system If any other surcharge loads are anticipated, SCS&T should be contacted for the necessary increase in soil pressure The passive pressure for the design of the proposed shoring system may be considered to be 350 psf per foot of depth up to a maximum of 5,000 psf The passive pressure may be assumed to act on an area equal to twice the soldier beam diameter. This value may be increased by % for seismic loading The upper 1 foot of embedment should be neglected when calculating passive pressures. Survey monuments should be installed at no more than 40-foot intervals along the perimeter of the excavation One row of monuments should be located just beyond the edge of the top of excavation. A second row should be established 10 feet beyond the excavation, and a third row should be set 20 feet from the top of the excavation A reference point should be established well away from the block where the excavation will take place. The horizontal and vertical location of each monument should be established with a survey instrument before excavation starts. Readings should be made daily during the initial stages of excavation, say for up to one week Results of the initial readings will be reviewed by SCS&T and modifications to the monitoring schedule may be made, depending on these results. Significant sloughing and erosion of the slopes should be anticipated. In addition, construction activities above or near the slopes could affect overall stability The slopes should be observed by a representative of SCS&T periodically to ascertain that no unforeseen adverse conditions are observed The temporary slopes should be inspected daily by the contractor's Competent Person before personnel are allowed to enter the excavation. Zones of potential instability, sloughing or raveling should be brought to the attention of the Engineer and corrective action O'Day Consultants O'Day Medical Office Building 2020 Cassia Rd, Carlsbad, CA February 26, 2007 SCS&TNo 0611114-5 Page 3 implemented before personnel begin working in the trench No surcharge loads should be placed within a distance from the top of temporary cut slopes equal to half the slope height This opportunity to be of professional service is sincerely appreciated. /' Respectfully submitted, /;V SOUTHEBN CALIFORNIA SOIL & TESTING, INC. , " *v,/JoFpuntain, GE 2752 ' ' DBAkv (4) Addressee (1) Pacific Building Group, Attn Erik Nelson via-email Enk@pacificbuildinggroup.com (1) Anderson Drilling, Attn Mike Empizo via email - mempizo@andersondrilling com Attachments Figures 1,2,3,4 Appendix I Appendix II liIjli I]I 1CSnf APPENDIX I 1 I. I \ i 0 b U m I I I I I I I I I I I I I I I i II I I I I I I I I I I I I I I I N3->4 01 N300 O | N300 Ol | ro CDo I NiCOOl I cooo 1 co0Ol 1 O I I I I I I I I I i I I i i i i i I I I I I I I I I I I I I I I I I I O>V)m K>cn%•10CD o = o 10o•o o cc/) r • CO Iic c.o O" zo <J>%.•^h £ cn •n (5*c 4t 07 • • O"n O OO o SFt • N) ro 0 O O mo o i- coc o ^5 G) f '^ -,\ jyJTL jf'i iij*1l|i * f GO GO 0 0 B C r ^R? ffi H Ww g IsPC h-Hgo P 5 H-4 Ol 1 1 1 1 1 1 1 N) N) ro N> M CO CO •^J OO 00 CO CD O OOl O Ol O Ol O Ol q •\) co ap 1 O CO >ill o 5 Q (Q (Q ffl 0 O ~ 0 O = 1 1~ 6 SUBSURFACE EXPLORATION LEGEND UNII llDSOILfl ASSII ICA I1ON CIIAKI SOIL DISC HUM ION (iROLIP SYMBOL (Yl'ltALNAMtS ( OAHSE f .RAINED, more than half of material it InrRcr fhan No 200 <ilcve size. Morc lluin halt ol coarse fraction is larger Ihun No 4 sieve si/e hut smaller than J" tl KANORAVUS (.RAVHS WIIIIHNhS (Appreciable amount ol lines) CiW Well jjr.uled gravels gravel-sand mixtures, little or no lines dP Poorly graded gravels gravel sand mixtures little or no lines CiM Silty gravels poorly graded gtavcl-sand-silt mixtures CiL t laycy gravels pm>rly graded gravel-sand, cluy mixtures SANDS. More lluin hull ol coirse Iraction is smnller than No 4 sieve size CLEAN SANDS SANDS Wild I INLS I Appreciable amount ot fines) SW Well graded sand, gravelly stinds, little or no fines SP Poorly graded sands, gravelly sands, little or no lines SM Silty saiuls poorly gnided sand and silly mixtures SC C layey sands, pool ly graded sand and elay mixtures II MNK <.RAINED, more than half of material Is smaller than No 2UO sieve si/e SILTS AND CLAYS Liquid Limit less than 50 ML Inorganic silts and very line sands, rock Hour, sandy sill or elaycy-sill-sand mixtures with slight plasticity C L Inorganic clays ot low to medium plasticity, gravelly clays, sandy clnys, silty clays, lean clays OL Organic silts and organic silty clays or low plasticity SILTS AND CLAYS MH Inorganic silts, mieaceous or dialomaccous fine Liquid Limit greater than 50 sandy or .silly soils, elastic silts C H Inorganic clays of high plasticity, fat clays OH Organic elays ot medium to high plasticity Ill HIGHLY ORGANIC SOILS PT 2 - US SC CON - El MS - MAX - ST SPT - pH - SF/CL - Water level at time of excavation or as mdii.ntcd Undisturbed, driven ring sample or tube sample Sand Cone Consolidation Expansion Index Maximum Size of Panicle Maximum Density Shelby Tube Standard Penetration Sample pH & Resistivity Sultate & Chloride Peat and other highly organic soils CK - [3 - DS - SA - PI - RC - UC - TX - RS - AL - RV - Undisturbed chunk sample Bulk Sample Direct Shear Sieve Analysis Plasticity Index Relative Compaction Unconfmed Compression Fnaxial Compression Ring Shear Atterberg Limits R Value C^r SOUTHERN CALIFORNIA ! S T? SOIL * TESTING, INC.\^ TIW. ODAY MEDICAL OFFICE BUILDING - ROAD WIDENING BY- DBA JOB NUMBER 0611114 DATE 2/26/2007 APPENDIX 1 1-1 I LOG OF EXPLORATORY BORING NUMBER B-1 Date Excavated 2/16/2007 Equipment CME 55 Surface Elevation (ft) 303 i£? i 0. LUa - 2 - 6 - 8 _ in - 12 - 14 - 16 - 18 on CO r) SM CI- SC CL Logged by MM Project Manager GBF Depth to Water (ft) N/A SUMMARY OF SUBSURFACE CONDITIONS ASPHALT - 6 Inches FILL(Qaf) - Brown, moist, dense, SILTY SAND ASPHALT - 3 inches FILL(Qaf) - Brown to gray, moist, soft, SILTY CLAY FILL(Qaf) - Light brown, moist, CLAYEY SAND loose to medium dense, FILL(Qaf) - Dark brown, moist, soft, SANDY CLAY S C, SOUTHERN CALIFORNIA i ST? SOIL & TESTING, INC.v^v. SAMPLES Q IIICDQ; 3 CO Q ID IDCD \J Ar\ -r "3"? > H ^ENETRAows/ft o°- e US \ j| 13wIM us[ us 19 15 o£ UJ t£ Z) COo o H ^ zID a: Q r3 CO LU a:ORATOCQ ^ ODAY MEDICAL OFFICE BUILDING - ROAD WIDENING BY AP/GBF JOB NUMBER 0611114 t DATE 2/26/2007 APPENDIX 1 1-2 I LOG OF EXPLORATORY BORING NUMBER B-1 (continued) Date Excavated 2/17/2007 Equipment CME 55 Surface Elevation (ft) 303 5?! UJa - 22 -24 - 26 - 28 -30 - 32 - 34 - 36 - 38 - 40 OT O (/} 3 SM SM \ Logged by MM Project Manager GBF Depth to Water (ft) N/A SUMMARY OF SUBSURFACE CONDITIONS FILL(Qaf) - Ligth brown to tan, moist, dense, SILTY SAND SANTIAGO FORMATION(Ts) - SILTY SAND Light brown, moist, very dense PRACTICAL REFUSAL @ 26 FEET <C1. SOUTHERN CALIFORNIA I d*l SOIL & TESTING, INC.ISrH/X— ?V_ SAMPLES UNDISTURBEDus x a GO PENETRATION(blows/ ft ofdnve)53 MOISTURE (%)^3. 1- zz> ccQ LABORATORY TESTSO'DAY MEDICAL OFFICE BUILDING - ROAD WIDENING BY: AP/GF JOB NUMBER 0611114 DATE: 2/27/2007 APPENDIX I I-3 LOG OF EXPLORATORY BORING NUMBER B-2 Date Excavated 2/16/2007 Equipment CME 55 Surface Elevation (ft) 303 *-* ^^,I Q_LU Q - 2 - 4 - 6 - 8 - 10 B -12 - 14 - 16 - 18 cooCO SM CL ML SM Logged by MM Project Manager GBF Depth to Water (ft) N/A SUMMARY OF SUBSURFACE CONDITIONS ASPHALT - 6 Inches FILL(Qaf) - Brown, moist, dense, SILTY SAND FILL(Qaf) - Brown to gray, moist, soft, CLAY FILL(Qaf) - Light brown to tan, moist, stiff, SANDY SILT SANTIAGO FORMATION(Ts) - SILTY SAND Light brown, moist, very dense. REFUSAL @ 17 FEET SAMPLE Oii COa: i_co Q 7" US US us 3 m z ?O c I!h- *• 2 1uj 5Q- 3 12 25 71 3? LU 01 ID co 0 ^ £ z3 >- Q 1°COLU >-i*e^o <-1 'S i <L SOUTHERN CALIFORNIA ( ST? SOIL * TESTING- INC- V^^w ODAY MEDICAL OFFICE BUILDING - ROAD WIDENING BY AP/GBF JOB NUMBER 0611114 / DATE 2/26/2007 I APPENDIX 1 1-4 1 I LOG OF EXPLORATORY BORING NUMBER B-3 Date Excavated 2/16/2007 Logged by MM Equipment CME 55 Project Manager GBF Surface Elevation (ft) 303 Depth to Water (ft) N/A I Q. 01 Q - 2 - 4 - 6 - 8 - 10 - 12 - 14 - 16 - 18 _ on t/JO Z) sw CL SM SUMMARY OF SUBSURFACE CONDITIONS ASPHALT - 6 Inches FILL(Qaf) - Brown, moist, dense, WELL GRADED SAND FILL(Qaf) - Brown to gray, moist, soft. SILTY CLAY SANTIAGO FORMATION(Ts) - Light brown, moist, very dense, SIL SILTY SAND REFUSAL® 15 FEET SAMPLE UNDISTURBEDus us a IPENETRATION(blows/ ft ofdnve)17 73 MOISTURE (%)t oe Q LABORATORY TESTSi "1 «. SOUTHERN CALIFORNIA ODAY MEDICAL OFFICE BUILDING - ROAD WIDENING SOIL & TESTING, INC. BY AP/GBF JOB NUMBER- 0611114 / DATE 2/26/2007 APPENDIX I I-5 I APPENDIX II I f I i ! I ] fl I ! D J £1I i I I T n i i i•i I 50 45 40 3i Shear Stress (ksf)"= 0 -> - M K> U_° 0< 0 ui 0 If 0Direct Shear Test Results ... _ .- • Shear Strength at 02 inches of Deformation l + ' - ^ ' * I i • * • i \Iii * rI I [ ' j — - -- 3 05 10 15 20 25 30 35 40 45 50 Confining Pressure (ksf) SAMPLE DESCRIPTION INTERNAL FRICTION ANGLE(DEG COHESION INTERCEPT (PSF) B2@6-6 5 Shear Strength at Tan, Clayey Sand 27 98 0.2 Inches of Deformation SOUTHERN CALIFORNIA SOIL & TESTING O'DAY MEDICAL OFFICE BY JJS/GBF JOB NUMBER 0611114 DATE 2/27/2007 APPENDIX 11-1 I I so 45 40 35 I" £ 25 I CO 20 15 10 05 00 0 Direct Shear Test Results - • Shear Strength at 0 2 inches of Deformation — - - — — - - - - — •*> I , * • P - I i * - - — * <• .... : 1 - - - -- - - i r — i . -_ .. , 0 05 10 15 20 25 30 35 40 45 50 Confining Pressure (ksf) SAMPLE DESCRIPTION INTERNAL FRICTION ANGLE(DEG COHESION INTERCEPT (PSF) B1@11-11 5 Shear Strength at Brown, Clay 33 333 0 2 inches of Deformation SOUTHERN CALIFORNIA SOIL & TESTING O'DAY MEDICAL OFFICE BY JJS/GBF JOB NUMBER 0611114 DATE 2/27/2007 APPENDIX 11-2