Loading...
HomeMy WebLinkAboutDWG 475-6; 3557; CARLSBAD BL OVERHEAD RETAINING WALL REHABILITATION; 01-051 1 I, I I I I I I j' CARLSBAD BOULEVARD PROJECT SITE 0 ~·\ ORIGINAL SCALE OF FULL SIZE PLANS (INCHES) 2 KLEINFELDER 3 • Bright poop/e, Right Solutions ,:,_ '~,;~ Simon Wong Engineering 550 West C Street Suite 1200 San Diego, CA 92101 -Lel._(619) 831-4600 Fax. (619) 232-1039 ..---,....,..=,..-.-- . --~-~ RD on c'1!! ,.~· (n ~~ "\ ALOA<S) 11 PKWY l u "' ~ ,f cosr~ A VICINITY MAP NOT TO SCALE PLAN SYMBOLS/ ABBREVIATIONS BOF TOW TOF HP SD BOTTOM OF FOOTING TOP OF WALL TOP OF FOOTING HIGH PRESSURE STORM DRAIN -INDICATES SECTION IDENTIFIER -INDICATES CALTRANS STANDARD PLAN REFERENCE CONSTRUCT/ON PLANS FOR OVERHEAD RETAINING WALL REHABILITATION PROJECT BRIDGE NO. NO 3557 57C-0134 CITY OF CARLSBAD CARLSBAD, CALIFORNIA CITY COUNCIL MATT HALL -MAYOR MARK PACKARD -MAYOR PRO TEM KEITH BLACKBURN -COUNCIL MEMBER LORRAINE WOOD -COUNCIL MEMBER MICHAEL SCHUMACHER -COUNCIL MEMBER STEVEN R. SARKO2Y CITY MANAGER GLEN K. VAN PESKI CITY ENGINEER "DECLARATION OF RESPONSIBLE CHARGE" I HEREBY DECLARE THAT I AM THE ENGINEER OF WORK FOR SHEETS 1-5 OF THIS PROJECT, THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BY THE CITY OF CARLSBAD DOES NOT RELIEVE ME AS ENGINEER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. FIRM: __ S=IM-e--'O~N_W=O~N~G ~E~NG=IN~E=ER=IN~G~-- ADDRESS: 9968 HIBERT STREET, SECOND FLOOR CITY, ST: SAN DIEGO CA 92131 ::LE_P-,HO~Vi,_,_,r:r_~: "'-8'--8~,fb..,,66s-~~'"1d.~i'7·-=~---DATE: tfJ MARK PLO~Z RCE NO: 058609 REGISTRATION EXPIRATION DATE: 12-31-14 b-2G~ 14 PROJECT SITE -- SHEET NUMBER 1 2 3 4 5 ..p_ "<(,,..,. ~ ·J'l '1< ·~ O~-" \ ~· ' " LOCATION MAP NOT TO SCALE INDEX TO PLANS DESCRIPTION TITLE SHEET RAILROAD NOTES AND DETAILS RETAINING WALL FOUNDATION PLAN RETAINING WALL SECTIONS NO. 1 RETAINING WALL SECTIONS NO. 2 CONTACT NCTD FOR RAILROAD UTILITY CALLOUT THE CONTRACTOR SHALL CONTACT "UNDERGROUND SERVICE ALERT" AT LEAST TWO DAYS BEFORE ANY EXCAVATION WORK AT 1-800-227 -2600 "AS BUILT" RCE __ _ EXP, __ _ REVIEWED BY: INSPECTOR DATE DATE I SH1EET I CITY OF CARLSBAD WH. 5 r-------i---t--------------t-----+----+-----+----1 TRANSPORTATION DEPARTMENT t------+---+-------------+----+----+-----l----l TITLE SHEET --_iJ, '!: CARLSBAD BLVD. OH RETAINING WALL REHAB/LITA T/ON APP~~ ... / _,. ~j,[N K"!1~!'5-Kl t---+--t--------------+----+---+---l----1 CITY~1R LP~ ~ES 3 31 15 :fotf4 DATE INITIAL DATE INITIAL w Y: I PROJECT NO. I DR4AW715N,C-6NO. r----~--+--~----1 CHKD BY: MP 3557 OlHER APPROVAL CITY APPROVAL RVWD BY: JF DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION "','-.-'!),<,'"" ;<'"' -~:,?".:··,\, -, ' ,, ::a, Q_ N N r-,. s;--0 N '---Lf) N '---CD z 0 w (.? n:: :'.5 _J <( m <( m n:: <( ~ (.? 3: 0 s;--I Lf) N I CD 0 ~ 0 0 - m <( :r: w n:: _J _J <( 3: (.? z -z ~ n:: I :r: 0 I _J n:: <( u / CJ) I-z w ::a, w > 0 n:: Q_ ::a, (.? z _J <( n:: :r: 0 0 <( m Ul _J n:: <( u CD {J) (() / 0 0 (() / 0 0 <( u / z 0 CJ) > 0 w (.? 0 n:: m / (.? Ill 0 :r :E II) II) " r+ ..... ,j;::,, 0 .... -U'1 u, I en r t f t ' I ,1-'?~;~~.ii~>--.·. -------------![1111111111!!1!!!11•·------------------------------------------------------------------------------------------------------~.;~.:~j.:~ --· ,, ': ' ,. ' ,, ct NCTD MAIN TRACK ct BENT 2 ct BENT 3 I I' BENT 4) EXISTING BARRIER TO BE REMOVED AND REPLACED WITH TYPE C411 (MODIFIED) ct BENT 5 -----zz--7·-z:,--r;_ "17--::;~-z=7:7-:Z7..7--~ L_72._7..T7_T7_ / -z,.r·;;cz:-T -,r-7/,-,---// -,-,- ~-~~~/,-/(f7.;~ i~' ~ r✓ ~ ;-1/ vv;:~ ~" /: ~ ~'"~ ~v/ /v~v~C:: ~: ~ Y ~"~~~:~I~ /0 1/ ~/''1/ ~ v~~ I//~:~~":::/~ v71;7}v? v/,;\_~--;7V;-;,~~ ,,, vJYlr I/ V V I/ / -."'=:Y':: ".: y -- - -/_ -- -• T/ - ----,<-,<-C -f'L...j4. ±LJA. :l"--,/l"'-V I/ I/ / I/ V I/ - ~----1 I - - f-I I I I I 8' -6" HORIZONTAL CLR I REQUIREMENTS I PER AREMA & CPUC I I I I I z <( I w :::e I z w <( ct: :::e <( I ct: I w ct: I (]_ w (]_ (0 I I I N N EXISTING I • 18' -6"± I I EXISTING EXISTING '-1----------c-c-~~----------I ~----'c-~-------•1 I~ I 8' -6"± 8' -6"± I I I I EXISTING 18'-6"± I I I EXISTING I CRASH WALL I I I I I I I I ! ~ I ! : ! I : TOP OF I I I I I RAIL I I I I : .I I I I I ------ff --'----"----ff --------' I I I , , I I 1 })'/',)'.:"~');l l~;~<;?,'°'y/ I BENT 2 ORIGINAL SCALE OF FULL SIZE PLANS (INCHES) BENT 3 BENT 4 BENT 5 RAILROAD CLEARANCE DIAGRAM 1/4" = 1'-0" NCTD CONTACT INFORMATION: I I I I I I I NOTES: 0 1 2 3 NCTD GENERAL NOTES: 1. FOR ALL EMERGENCIES AFFECTING THE TRACK AND TRAIN SAFETY, CALL NORTH COUNTY TRANSIT DISTRICT'S (NCTD) 24 HOUR SECURITY OFFICE AT (760) 966-6700. 2. PRIOR TO THE START OF CONSTRUCTION AND AT THE CONTRACTOR'S EXPENSE, ALL PERSONNEL ENTERING THE RIGHT-OF-WAY (ROW), INCLUDING SUBCONTRACTORS AND THIRD PARTIES, SHALL COMPLETE NCTD'S ROADWAY WORKER PROTECTION (RWP) TRAINING COURSE. CONTACT TRANSIT AMERICA SERVICES, INC. (TASI) AT (760) 966-6514 TO ARRANGE FOR TRAINING. 3. ALL PERSONS ENTERING THE RAILROAD ROW SHALL HAVE THE RWP STICKER AFFIXED TO THEIR HARD HAT AND RWP BADGE IN THEIR POSSESSION. 4. ALL PERSONNEL ENTERING THE RAILROAD ROW SHALL COMPLY WITH NCTD SAFETY REQUIREMENTS. FAILURE TO COMPLY SHALL BE GROUNDS FOR TERMINATION OF WORK AND REVOCATION OF THE RIGHT TO ENTER NCTD'S ROlf.J AND/OR RIGHT-OF-ENTRY (ROE) PERMIT. 5. THE CONTRACTOR OR ENTITY BEING ISSUED AUTHORIZATION BY NCTD TO WORK IN THE ROW (CONTRACTOR) SHALL COMPLY WITH ALL APPLICABLE TERMS, CONDITIONS AND REQUIREMENTS OF NCTD'S POLICIES REGARDING NCTD' ROW AND OTHER NCTD ORDINANCES, RULES AND REGULATIONS. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE LAWS AND REGULATIONS OF THE FEDERAL, STATE, COUNTY, LOCAL GOVERNMENTS AND ALL ADMINISTRATIVE AGENCIES WHICH MAY HAVE JURISDICTION OVER THE CONTRACTOR'S WORK OR WORK AREA. 6. THE CONTRACTOR SHALL PAY ALL COSTS ASSOCIATED WITH RWP TRAINING, FLAGGING, INSPECTIONS, AND REVIEWS AS REQUIRED IN THE ROE PERMIT AND/OR WORK AUTHORIZATION LETTER. 7. NO WORK SHALL BE PERFORMED WITHIN THE RAILROAD ROW WITHOUT A ROE PERMIT AND/OR WORK AUTHORIZATION LETTER, AS APPLICABLE. THE CONTRACTOR SHALL ADHERE TO ALL REQUIREMENTS SET FORTH BY NCTD, THE ROE PERMIT, THE WORK AUTHORIZATION LETTER, PROJECT PLANS AND SPECIFICATIONS, AND THE JOB SITE RAILROAD FLAGMAN/EMPLOYEE-IN-CHARGE (EiC). FAILURE TO COMPLY MAY RESULT IN WORK STOPPAGE OR REMOVAL FROM NCTD PROPERTY. 8. ONLY AN NCTD AUTHORIZED RAILROAD FLAGMAN (RAILROAD FLAGMAN) IS PERMITTED TO PERFORM FLAGGING OPERATIONS WITHIN THE ROW. NO PERSONNEL SHALL CROSS ANY TRACK WITHOUT THE APPROVAL FROM THE RAILROAD FLAGMAN. NO MEN OR EQUIPMENT SHALL BE ACTIVELY WORKING, PARKED OR STATIONARY ON NCTD'S ROW WITHOUT PRIOR APPROVAL FROM THE RAILROAD FLAGMAN. 9. A RAILROAD FLAGMAN SHALL BE PRESENT DURING ALL CONSTRUCTION RELATED ACTIVITIES. THE RAILROAD FLAGMAN/ EiC HAS SOLE RESPONSIBILITY TO PROTECT THE RAILROAD INFRASTRUCTURE AND OPERATIONS. AT ALL TIMES, THE CONTRACTOR SHALL FOLLOW THE RAILROAD FLAGMAN/EIC'S DIRECTION. 10. CONTRACTOR IS RESPONSIBLE TO REQUEST RAILROAD FLAGMAN SERVICES WITH ADEQUATE NOTICE TO MEET CONTRACTOR'S CONSTRUCTION SCHEDULE. 11. THE CONTRACTOR SHALL MAKE THE NECESSARY ARRANGEMENTS FOR EACH EQUIPMENT OPERATOR TO HAVE , CONSTANT AND DIRECT RADIO CONTACT WITH THEIR FOREMAN. THE FOREMAN WILL IN TURN HAVE CONSTANT AND. DIRECT CONTACT WITH THE RAILROAD FLAGMAN/EiC. 12. THE CONTRACTOR SHALL HAVE THE PERMITTED STAMPED SET OF PLANS ON-SITE. WORK WILL BE TERMINATED BY NCTD SHOULD NO STAMPED PLANS BE ON-SITE. 13. IF APPLICABLE, ALL WORK ON OR ADJACENT TO THE SAN DIEGO TROLLEY SHALL ALSO ADHERE TO METROPOLITAN TRANSIT SYSTEM (MTS) REQUIREMENTS. 14. THE MOVEMENT OF TRAINS IS UNPREDICTABLE. TRAINS MAY APPROACH THE JOB SITE IN ANY DIRECTION,',>AT ANY SPEED, AT ANY TIME, AND MAY STOP AND OCCUPY THE TRACK WITHIN THE CONTRACTOR'S WORK ZONE FOR AN UNDETERMINED PERIOD OF TIME. 15. CONTRACTORS MUST CONTACT CALL BEFORE YOU DIG (811) BEFORE ANY EXCAVATION OCCURS WITHIN THE ROW. 16. NCTD RAILROAD UTILITIES ARE NOT A PART OF CALL BEFORE YOU DIG. CONTRACTOR MUST REQUEST RAILROAD UTILITIES LOCATED BEFORE ANY EXCAVATIONS CAN OCCUR BY CALLING NCTD AT (760) 967-2883 FOR SIGNALING AND PTC FIBER MARK-OUTS WITHIN THE ROW AT LEAST SEVEN (7) WORKING DAYS BEFORE DIGGING. 17. THE CONTRACTOR SHALL CONTACT NCTD AT (760) 967-2883, 72-HOURS IN ADVANCE FOR ANY INSPECTIONS REQUIRED IN THE ROE PERMIT AND/OR WORK AUTHORIZATION LETTER, AS APPLICABLE. 18. UPON PROJECT COMPLETION, THE NCTD ROW SHALL BE LEFT IN AS GOOD IF NOT BETTER CONDITION. NCTD PROPERTY SHALL NOT BE USED FOR SPOILS. "AS BUILT" RCE __ _ EXP ___ _ REVIEWED BY: DATE --·-' . INSPECTOR •.. DATE fsHiITl CITY 0ft' CA.t<LSBAV ·~ t----+---+--------------t----+---t-------1 ~ TRANSPORTATION DEPARTMENT ~ t----+---+--------------t----+---t-------1 t---+--+-------------+---+--+----lf----11 ~NT PLAN FOR: I . -. . , ,, KLE!tVFELDER NCTD SECURITY (24/7) MANAGER OF RAIL OPERATIONS RIGHT -OF-WAY OFFICER (760) 966-6700 (760) 966-6682 (760) 966-6688 1. THE CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES, VALVE BOXES, MANHOLES, VAULTS, SEWER CLEANOUTS, STORM DRAIN GRATES, INLETS AND SURVEY MONUMENT BOXES AND PROTECT IN PLACE. RAILROAD NOTES ANO DETAILS I, CARLSBAD BLVD. OH RETAINING WALL REHABILITAfiON j' ~ Brighi people, Rigfrf Solutions. 1 /VA\F\ Simon Wong Engineering 550 West C Street Suite 1200 San Diego, CA 92101 :Cel. (619) 831-4600 Fax, (619) 232-1039 i: k,-- --<--, .. ___ $, .. ,:..c--a--'-------"---.c-·-- 2. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS BEFORE ORDERING OR FABRICATING ANY MATERIAL. DATE INITIAL ENGINEER OF WORK APPR~ :;i --u. ~PESKJ ENINEER PE 41204 . EXPIRES 3/31 /15 REVISION DESCRIPTION rliwN BY: IO I PROJECT NO. DATE INITIAL DA TE INITIAL MP o--~---~----1 CHKD BY: 3557 OTHER APPROVAL CITY APPROVAL RVWD BY: JF I DRAWING NO. _ .. 475-6 · : : . :::e (]_ N N r--- -sj- ~ 0 N '--L[) N '----(0 z 0 w (5 ct: :'5 _J <( CD <( CD ct: <( Y'. (5 :s: 0 -sj- ~ I L[) N I (0 0 ~ 0 0 ~ CD <( :r: w ct: _J _J <( :s: (5 z z ;'S w ct: I :r: 0 I _J ct: <( u / (f) f-z w :::e w > 0 ct: (]_ :::e (5 z _J <( ct: :r: 0 0 <( CD (f) _J ct: <( u (0 "' OC) / 0 0 OC) / 0 0 <( Ill 0 u / ~ :E z CD ~ 0 CD (f) .... > N ~ 0 0 ...., w -+, V1 (5 V1 I 0 (JI ct: CD / (5 i i r!:~":!;:" ,, I ',! ,, ,, :, ,, I ,, ! Simon Wong Engineering 550 West C Street Suite 1200 San Diego, CA 92101 _Jel. (619) 831-4600 Fax. (619) 232-1039 .--e~-,c.~~, : __ -.•. -"·-----------·'"""---c-- ---------40 NOTES: 1 . I /r--~ RAILROAD TOW EL. -37.00± TOF EL. -26.00+ E INDICATES BOTTOM OF FOOTING ELEVATION (FEET, MSL) FOR RETAINING WALLS (ELEVATIONS ARE APPROXIMATE AND SHALL BE DETERMINED IN FIELD) 2. FOR SECTIONS A-A AND B-B, SEE "RETAINING WALL SECTIONS NO. 1" SHEET. FOR SECTIONS C-C, D-D, AND E-E, SEE "RETAINING WALL SECTIONS NO. 2" SHEET. 3. REPAIR THE EROSION DAMAGE TO THE SLOPES BEHIND AND ADJACENT TO THE RETAINING WALLS. USE NATIVE MATERIAL EXCAVATED FROM BEHIND THE RETAINING WALLS AS FILL MATERIAL. ALL EXCESS MATERIAL SHALL BECOME PROPERTY OF THE CONTRACTOR AND DEPOSITED OFF-SITE. 4. TEMPORARY STORMWATER BMP'S MUST BE USED DURING CONSTRUCTION AND APPROVED BY THE ENGINEER. AT THE COMPLETION OF THE PROJECT, INSTALL PERMANENT EROSION CONTROL, AS APPROVED BY THE ENGINEER, TO ALL DISTURBED AREAS BEHIND THE RETAINING WALLS. PLAN 1" = 10' Cf. NCTD --- MAINLINE TRACK CARLSBAD BLVD y / SPECIFICATIONS STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (GREEN BOOK) 2012 EDITION -" ;, SUPPLEMENTAL PROVISIONS FOR CARLSBAD BOULEVARD OVERHEAD RAILING IMPROVEMENTS AND RETAINING WALL REHABILITATION THE CONTRACTOR SHALL CONTACT "UNDERGROUND SERVICE ALERT" AT LEAST TWO DAYS BEFORE ANY EXCAVATION WORK AT 1-800-227-2600 CONTACT NCTD FOR RAILROAD UTILITY CALLOUT ' I NOTES: 1. THE CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES, VALVE BOXES, MANHOLES, VAULTS, SEWER CLEANOUTS, STORM DRAIN GRATES, INLETS AND SURVEY MONUMENT BOXES AND PROTECT IN PLACE. 2. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS BEFORE ORDERING OR FABRICATING ANY MATERIAL. "AS BUILT" RCE __ EXP.___ DATE REVIEWED BY: ..__, .,.!' INSPECTOR DATE fSHFill CITY OF CARLSBAD 1~.' 1----+---+---------------+----1----+------+-----I ~. TRANSPORTATION DEPARTMENT . _ L.J2.._J t---+---+--------------+---t----+----t----1 RETAINING WALL FOUNDATION PLAN -,Jt1,+ DATE DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION DATE INITIAL DA TE INITIAL OTHER APPROVAL CITY APPROVAL W BY: CHKD BY: MP RVWD BY: JF I PROJECT NO. 3557 I DRAWIN'G NO. 475-6 ::, 0.. N N r--- ..,- ~ 0 N -------LO N ------- (0 z 0 w (.'.) [l'.'. ::5 _J <( m <( m [l'.'. <( :,,:: (.'.) ,:: 0 ..,- ~ I LO N I (0 0 ~ 0 0 ~ m <( :r: w [l'.'. _J _J <( ,:: (.'.) z -z ~ [l'.'. I :r: 0 I _J [l'.'. <( u / (J1 f-z w ::, w > 0 [l'.'. 0.. ::, (.'.) z _J <( [l'.'. :r: 0 0 <( m (J1 _J [l'.'. <( u (0 Ol co / 0 0 co / 0 0 VI 0 <( u :::r :E / 11) z 11) C) 0 r+ (J1 w .i::,, > 0 0 -..J -U1 w U1 I (.'.) C'\ 0 [l'.'. m / (.'.) ' ' I ~;;..;. __ ,-=:::_ ;,, 0 " 0 I --EXISTING GRADE IN FRONT OF WALL TOW 38.0'± " 0 I " n GROUT BULB TYP ---r ( 4' -0" CENTER TO CENTER SPACING) 12'-o"± EXISTING TYPE 5 RETAINING WALL SECTION A-A 1/4" = 1'-o" _,.--RETAINING WALL GUTTER e ?' . . f.-.--1 ' - 0 " . ~.< Cl CXJ L .. ,;,,/:>J;; I ---'"--, /,<\>· "~1 ~I--.--__,_~_ __✓_,/_,/;, __ COMPACTED NATIVE MATERIAL ~~t-t + "-1 ~~ ,' \ (90% RELATIVE COMPACTION) -t--'-----"-----i ~ -'~ 12 3/4"¢± HP GAS MAIN 4'-0"± I L,.,., ... ,.,._J-.-------(SOUTHERN CALIFORNIA )GAS) 3/8" PEA GRAVEL~~ (PROTECT-IN-PLACE ::::::::::::J FILTER FABRIC +I 0 I " n ~=J=~ ..... : d '\_.:' i«?:~~~:~: --4"¢ PERFORATED DRAIN PIPE (SCHEDULE 40 · .. :;;:,Y) __ ·_·V:_'1/,'/'°" ,,v,.;,;;1 OR EQUIVALENT) INSTALL WITH PERFORATIONS DOWN. '\':l, .;-:(~:!' 1 1 % MIN GRADIENT, OUTLET AT END OF WALL. / «?:'Y_;)• '"-.,,!-....', '< DRAINAGE DETAIL 3/8" = 1 '-0" ORIGINAL: SCALE OF ' FULL SIZE PLANS (INCHES) 1 2 3 1 KLEINFELDER /VA\r\ . Bright µeuµfo, Righi So/ii/Ions, ~ BENT 2 PIER WALL TOF 20.5'± BOF 17.0'± LEGEND V ~ NCTD MAIN TRACK I 8' -6"± CLEAR ,...---~ BENT 3 1. 21 '-8"± ZONE OF SOIL IMPROVEMENT TOP OF RAIL ELEV 25.0'± NOTE: EXISTING 1 1 CRASH WALL \.-1 --2'-0"± GROUT INJECTION TUBES -- ( 4' -0" CENTER TO CENTER SPACING) +I " 0 I " a, 0 I " n 1. INJECTION TUBES MUST BE REMOVED FROM NCTD RIGHT -OF-WAY AFTER WORK IS COMPLETED. 50' -0"± 3' -o"± 1'-0"± TOW 38.0'+ I 3' -0"± I .1 ~ BENT 2 EXISTING 6'-0"+ CHAIN LINK FENCE NCTD FT-OF-WAY I _,....-----12 3/4"¢± HP GAS MAIN ~T ( 'SOUTHERN CALIFORNIA GAS) ,I_, c--_, (PROTECT-IN-PLAfE) 1 3' -0"± FOR DRAINAGE, SEE "DRAINAGE 1 '-o" BOF 27.5'± +I (D I / / DETAILS" THIS SHEET / ...---APPROXIMATE LIMIT OF EXCAVATION FROM PAST RETROFIT PROJECT y / / I . 10'-o"± GROUT BULB TYP (4'-0" CENTER • TO CENTER SPACING) ~3 V RETAINING WALL GUTTER SECTION B-8 +I w l ~Q_ .. g N(J) 2' x 4' x 4" CONCRETE SPLASH PAD (MATCH EXISTING DITCH SECTION) .._____ 2' -0" MIN EXISTING RETAINING WALL RADIUS 2'-0" -~-'--L,_--'-----.---'r TOE OF SLOPE !] __:XISTI~ DIT~ I 4• -o" • • NOTES: 1. SOUTHEAST RETAINING WALL SHOWN, NORTHWEST RETAINING WALL SIMILAR. 2. ADJUST GUTTER LAYOUT TO FIT EXISTING CONDITIONS. RETAINING WALL GUTTER END PLAN NO SCALE 1/4" = 1'-0" THE CONTRACTOR SHALL CONTACT "UNDERGROUND SERVICE ALERT" AT LEAST TWO DAYS BEFORE ANY EXCAVATION WORK AT 1-800-227 -2600 CONTACT NCTD FOR RAILROAD UTILITY CALLOUT NOTES: 1. THE CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES, VAL VE BOXES, MANHOLES, VAULTS, SEWER CLEANOUTS, STORM DRAIN GRATES, INLETS AND SURVEY MONUMENT BOXES AND PROTECT IN PLACE. 2. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS BEFORE ORDERING OR FABRICATING ANY MATERIAL. "AS BUILT" RCE __ EXP. __ _ REVIEWED BY: INSPECTOR DATE . DATE RETAINING WALL SECTIONS NO. 1 CARLSBAD BLVD. OH RETAINING WALL REHABILITATION AP~ ~ ..fl9JK. Y};_:[jK. I , 1---4---1--------------+---+--+---t----t CITY~R ~E ~ ~s 3 31 1s ¾Wt' Simon Wong Engineering 550 West C Street Suite 1200 San Diego, CA 92101 Tet.(619) 831-4600 Fax. (619) 232-1039 NOTE: FOR LOCATIONS OF SECTIONS A-A AND B-B, SEE "RETAINING WALL FOUNDATION PLAN" SHEET. DATE INITIAL REVISION DESCRIPTION WN BY: ----cc'cc--PROJECT NO. ~DA_TE__.,_IN-'ITIA_L-+-D_ATE_._IN_IT_IA--fL CHKD BY: MP 3557 I DRAWiNG NO. ,475-6 ENGINEER OF WORK OTHER APPROVAL CITY APPROVAL RVWD BY: JF ::;; o_ n N r-- st" ~ 0 N '-._ LO N '-._ <D z 0 w l') et: 5 _J <( (D <( (D et: <( '<'. l') 3: 0 st" ~ I LO N I <D 0 ~ 0 0 ~ (D <( :r: w et: _J _J <( 3: l') z z <( w et: I :r: 0 I _J et: <( u / (/] f--z w :::, w > 0 et: o_ ::;; l') z _J <( et: :r: 0 0 <( (D (/] _J et: <( u <D O'l CD / 0 0 CD / 0 0 <( u VI 0 / z :r :e 0 I?) (/] I?) G) > .... 0 .i::,. .i::,. w 0 ..... l') -u, 0 u, I et: O'l (D / l') ' l l ! f I l ' l I I I l' i i i i' ' ' ! I " j i ' '. ' ii ,. i I ;. ' j;1 " ' ,, ,, Jii· ' +1 0 I -LI; 0 BENT 2 PIER WALL TOW 37.0'+ 19'-o"± EXISTING TYPE 5 RETAINING WALL TOW 37.0'± EXISTING GRADE IN ---. FRONT OF WALL .. LEGEND ZONE OF SOIL IMPROVEMENT TOW 32.0'+ v-~ NCTD MAIN TRACK 8'-6"± CLEAR r~y$;<;~,~-;«"%~ ~<:/t:;·~~?:.~~>-</l..~v~:~:;,)~i;§~::f$:J:/i:.::::'1~~~·l~~i;;,JS;,~~~,~~~~::::;1;::$;.::ffi~~o/>:'. EXISTING\ I TOF 28.0'+ ElOF 26.5'+ I I I --------------------------~--------! I / TOF 26.0'+ BOF 24.5'+ -0 I -0 Q.. • I ~ 0-1 • CRASH WALL ~ TOP OF RAIL ELEV 25.0'± I TOF 20.5'+ ,__ __ N_-= t ,/'••-'"" r----GROUT BULB TYP (4'-0" CENTER TO CENTER SPACING) BOF 17.0'+ ORIGINAL SCALE OF FULL SIZE PLANS (INCHES) 1 2 3 -0 I -n 23'-o"± APPROX! OF EXCAVATION FROM PAST RETROFIT PROJEC g' -0"± SECTION C-C 1/4" = 1 '-0" ~ .NCTD MAIN TRACK 8' -6"± CLEAR .. ----- TOP OF RAIL ELEV 25.0'± A V ------~ BENT 3 21'-8"± GROUT INJECTION TUBE 1 ( 4' -0" CENTER TO CENTER SPACING) I TOW 32.0'± -H BOF 17.0'± SECTION E-E 3' -0"± ----- 1 '-0"± ---,-i AND VARIES 3'-o"± I I ---1 BENT 2 0 I NOTE: EXISTING 6' -0"± CHAIN LINK FENCE '1/' ~ >>>'' • ),~~ ~;',---'-12 3/4"¢± HP GAS MAIN ,. ;',/ (SOUTHERN CALIFORNIA GAS) 1'-0" -H lD I -H lD I (PROTECT-IN-PLACE) / / FOR DRAINAGE, SEE "DRAINAGE DETAILS" ON "RETAINING WALL SECTIONS NO. 1" SHEET / G APPROXIMATE LIMIT OF EXCAVATION FROM AST RETROFIT PROJECT a...:...'""'"'"...;........;.....,.'--"--'-""-"-' ___'0 L/ 10'-o"± GROUT BULB TYP ( 4' -0" CENTER TO CENTER SPACING CENTERED UNDER FOOTING) KLEINFELDER 1/4" = 1'-o" \~ Br/gh( people, Righi Soh1tfons. Simon Wong Engineering NOTE: FOR LOCATIONS OF SECTIONS C-C, D-D, AND E-E, SEE "RETAINING WALL FOUNDATION PLAN" SHEET. 5·50 West C Street Suite 1200 San Dlego, CA 92101 .Tel. (619) 831-4600 Fax. (619) 232-1039 --~ BENT 3 50' -0"± I . 21'-8"± A ' 3' -o"± ----- -1 ,,.---~ BENT 2 EXISTING 6' -0"+ CHAIN LINK FENCE • I NCTD . ~T-OF-V./AY GROUT INJECTION TUBE ( 4' -0" CENTER -H 0 I TO CENTER SPACING) -H 0 I -m 1 o· -o"+ . I 12 3/4"¢± HP GAS MAIN (SOUTHERN CALIFORNIA GAS) (PROTECT-IN-PLACE) I ----FOR DRAINAGE, SEE "DRAINAGE DETAILS" ON "RETAINING WALL SECTIONS NO. 1" SHEET I ---APPROXIMATE LIMIT BOF 26.5'± OF EXCAVATION FROM PAST RETROFIT PROJECT -H -lD I / / GROUT BULB TYP ( 4' -0" CENTER TO CENTER SPACING CENTERED UNDER FOOTING) I ' l ' SECTION D-D 1 / 4" = 1 • -o" 1 ,, ,-------------------, i NOTES.· THE CONTRACTOR SHALL CONTACT "UNDERGROUND SERVICE ALERT" AT LEAST TWO DAYS BEFORE ANY EXCAVATION WORK AT 1-800-227-2600 CONTACT NCTD FOR RAILROAD UTILITY CALLOUT "AS BUILT" 1. THE CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES, VAL VE BOXES, MANHOLES, VAULTS, SEWER CLEANOUTS, STORM DRAIN GRATES, INLETS AND SURVEY MONUMENT BOXES AND PROTECT IN PLACE. RCE __ EXP,___ DATE 2. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS BEFORE ORDERING OR FABRICATING ANY MATERIAL. REVIEWED BY: INSPECTOR DATE l---+----ll-------------1t-------t---t-----1t---il SH5EET I CITY OF CARLSBAD ~-:'..5 TRANSPORTATION DEPARTMENT LL£...j MPROVEMENT PLAN FOR: 1----+---+-------------t---i----a-----t--"1 RETAINING WALL SECTIONS N0.2 CARLSBAD BLVD. OH RETAINING WALL REHAB/LITA TION APPj,PXf:D ~/. ~ (jlEN MA!if_ESKI ~ £"Z/lk:,_ ~ z/-t/f'I 1----+---+-------------t---i----a-----t--"1 CITY ENGINEER PE 41204 EXPIRES 3 31 15 . DATE OWN BY: ---""c--PROJECT NO. I DR·A.WIN·G· NO. ,__DA_T_E ~IN_ITI_AL-_DA_TE __ IN_ITI_AL_, CHKD BY: MP 3557 475~6 OTHER APPROVAL CITY APPROVAL RVWD BY: JF f • DATE INITIAL ENGINEER OF WORK REVISION DESCRIPTION 2 Q_ n N r-- st ~ 0 N '-. l[) N '-. (0 z 0 w c.::, 0:: ~ _J <( m <( m 0:: <( ::,:: c.::, 3:: 0 st ~ I l[) N I (0 0 1--i: 0 0 ~ CD <( I w 0:: _J _J <( 3:: (.'.) z z ~ 0:: I I 0 I _J 0:: <( u / (/) f-z w 2 w > 0 0:: Q_ 2 c.::, z _J <( 0:: I 0 0 <( m (/) _J 0:: <( u (D Ol co / 0 0 co / 0 0 <( C u Vl / :J"' :e z It) 0 It) G) (/) r+ > U1 ,I:>, 0 0 ..... w -U1 c.::, U1 I 0 C'l 0:: m / c.::,