HomeMy WebLinkAbout2933 VIA IPANEMA; ; AS090103; Permit9/15/2020 AS090 103 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS090103 Job Address: 2933 VIA IPANEMA Status: ISSUED Permit Type: SPRINK Applied 9/1/2009 Parcel No: 2551441700 Approved: 9/1/2009 Lot #: 0 Reference No.: Issued: 9/1/2009 PC. #: Inspector: Project Title: ELICEIRI RESIDENCE THREE (3) FIRE SPRINKLER INSPECTIONS @ $65/EA Applicant: SYMONS FIRE PROTECTION SUITE R 1050 PIONEER WAY ELCAJON,CA 619-588-6364 Owner: ELICEIRI FAMILY TRUST 05-24-97 2933 VIA IPANEMA CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 195 0 195 0 / 1/1 I HYDRNICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. LICENSE 682025 DESIGNER : CANDI CAUDILLO DATE : 08-05-2009 FIE : 09-118 JOB NAME : ELICEIRI RESIDENCE 16'FT SLOPED LOCATION : 2933 VIA IPANEMA, CARLSBAD, CA These plans have been reviewed for apparent conipliattee with the current applicable codes and standards in force 'ii hi urisdiction. Iltt owner or Contractor stay ui l,.e 1111 review in support of an application for, a building permit with the express understanding that this review ill no way relieves the owner or contractor or their professional engineer or architect (hr sole responsibility for lull compliance with said codes and standards. itteludingthe huilding.eode or lhsr'any responsihihy for deficiencies. errors. omissions or negligence in these plaits whether or not noted in this revieS.v. Date:6'11,~107Reviewer: 4) 19 RECOMMEND APPROVAl. 0 REC 1MENl) APPROVAL. AS NOTED. DESIGN DATA; DESIGN CRITERION: MIN SPR FLOW AREA PER SPRINKLER TOTAL CALCULATED AREA TOTAL SPRINKLERS CALCULATED NFPA 13-D 13 Gpm 256 Sq Ft 512 Sq Ft 2 Heads TOTAL SPRINKLER FLOW DOMESTIC DEMAND TOTAL WATER REQUIRED: BASE OF RISER NODE: 8 FLOW: 26.0 Gpm 5.0 Gpm 31.0 Gpm 31.0 Gpm PRESSURE: 28.1 Psi AUTHORITY HAVING JURISDICTION : CARLSBAD FIRE DEPT. PHONE : 760-602-4666 HYRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020. Date: 08-05-2009 File: C:\RESDEN43\09-118.RES JOB : ELICEIRI RESIDENCE 16'FT SLOPED SOURCE I STATIC : 80.0 Psi RESIDUAL : 79.0 Psi FLOW .: 31 Gpm DESIGN I SPRINKLER MANUF : RELIABLE MODEL : RFC 43 CONC/FLAT I SPRINKLER Q : .0 Gpm VALVE : .0 Psi I SPRINKLER P : .0 Psi METER : 4.0 Psi NODE ELEVATION K- PRESSURE DISCHARGE NO. Feet FACTOR Psi Gpm 1 17.0 ----------------------------------------------------------- 4.3 9.1 13.0 2 17.0 4.3 9.1 13.0 3 14.0 13.7 4 14.0 13.7 5 14.0 16.4 6 14.0 19.1 7 14.0 23.3 8 9.0 28.1 5.0 DOME 9 5.0 33.1 10 3.0 42.1 11 .0 SOURCE 53.5 31.0 SPRINKLERS FLOWING : 2 AREA PER SPRINKLER : 256 Sq Ft TOTAL DESIGN AREA : 512 Sq Ft REQUIRED DENSITY : Gpm/Sq Ft COMPUTED DENSITY : .051 Gpm/Sq Ft TOTAL SPRINKLER FLOW : 26.0 Gpm TOTAL DOMESTIC FLOW : 5 Gpm TOTAL WATER REQUIRED : 31.0 Gpm TOTAL SPRINKLER PRESS : 49.5 Psi WATER METER LOSS : 4.0 Psi VALVE FIXED LOSS : .0 Psi Copyright (2002) SUPPLY PRESS AVAILABLE : 79.0 Psi by DEMAND PRESS REQUIRED : 53.5 Psi Hydronics Engineering PRESSURE CUSHION : 25.5 Psi 34119 Fremont Bl, Suite 609 Fremont, Ca., 94555 MAXIMUM VELOCITY : 12.8 F/S (510) 487-9160 HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page 2 ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020. Date: 08-05-2009 Pile: C:\RESDEN43\09-118.RES JOB : ELICEIRI RESIDENCE 161 FT SLOPED PIPE BEG FLOW. K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Pt) 1 q= 13.0 K= ------------------------------------------------------------------------------- 4.3 L= 11.0 Pt 9.1 Pt 9.1 1 Q= 13.0 F= 3L1B F= 24.0 C= 150 Fe 1.3 Pv -.3 Vel= 6.9 D= .874 TL= 35.0 .0943 Pf 3.3 Pn 8.8 4 --------------------------------------------------------------------------- Pt 13.7 2 q= 13.0 K= 4.3 L= 11.0 Pt 9.1 Pt 9.1 2 Q= 13.0 F=3L1B F= 24.0 C=150 Fe 1.3 Pv -.3 Vel= 6.9 D= .874 TL= 35.0 .0942 Pf 3.3 Pn 8.8 3 Pt 13.7 3 q= .0 K= .0 L= 8.0 Pt 13.7 Pt 13.7 3 Q= 1.2 F= 2B F= 6.0 C= 150 Pe .0 Pv .0 Vel= .6 D= .874 TL= 14.0 .0011 Pf .0 Pn 13.7 Pt 13.7 3 q= .0 K= .0 -------------------------------------------------------------------------- L= 22.0 Pt 13.7 Pt 13.7 4 Q= 11.8 F= 3R3B F'= 12.0 C= 150 Pe .0 Pv -.3 Vel= 6.3 D= .874 TL= 34.0 .0793 Pf 2.7 Pn 13.5 5 Pt 16.4 5 q= .0 K= .0 -------------------------------------------------------------------------- L= 24.0 Pt 16.4 Pt 16.4 5 Q= 11.8 F= 3R2B F= 9.0 C=.150 Pe .0 Pv -.3 Vel= 6.3 D= .874 TL= 33.0 .0793 Pf 2.6 Pn 16.2 6 Pt 19.1 4 q= .0 K= .0 -------------------------------------------------------------------------- L= 34.0 Pt 13.7 Pt 13.7 6 Q= 14.1 F= 5R3B F= 14.0 C= 150 Pe .0 Pv -.4 Vel= 7.6 D= .874 TL= 48.0 .1103 Pf 5.3 Pn 13.4 6 Pt 19.1 6 q= .0 K= .0 L= 18.0 Pt 19.1 Pt 19.1 7 Q= 26.0 F= 1R1B2L F= 20.0 C= 150 Fe .0 Pv -.5 Vel= 8.8 D= 1.101 TL= ' 38.0 .1103 Pf 4.2 Pn 18.6 7 ' Pt 23.3 7 q= .0 K= .0 -------------------------------------------------------------------------- L= 5.0 Pt 23.3 Pt 23.3 8 Q= 26.0 F= 1C4R1S1L 19.0 C= 150 Pe 2.2 Pv -.5 Vel= 8.8 D=.1.101 TL= 24.0 .1103 Pf 2.6 Pn 22.8 8 Pt 28.1 8 q= 5.0 DOME -------------------------------------------------------------------------- L= 5.0 Pt 28.1 Pt 28.1 9 Q= 31.0 F= 1G1B2L F= 10.0 C= 150 Fe 1.7 Pv -1.0 Vel= 12.0 D= 1.025 TL= 15.0 .2165 Pf 3.2 Pn 27.1 9 Pt 33.1 HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page 3 ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020. Date: 08-05-2009 File: C:\RESDEN43\09-118.RES JOB : ELICEIRI RESIDENCE 16'FT SLOPED PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) 9 q= .0 K= .0 ------------------------------------------------------------------------------- L= 50.0 Pt 33.1 Pt 33.1 10 Q= 31.0 F= 3C F= 3.0 C= 150 Pe .9 Pv -.7 Vel= 10.4 D= 1.101 TL= 53.0 .1528 Pf 8.1 Pn 32.4 10 Pt 42.1 10 q= .0 K= .0 -------------------------------------------------------------------------- L= 20.0 Pt 42.1 Pt 42.1 11 Q= 31.0 F= 2C F= 4.0 C= 150 Pe 1.3 Pv -1.1 Vel= 12.8 D= .995 TL= 24.0 .2502 Pf 6.0 Pn 41.0 11 S S Pt 49.5 Meter = 4.0 12 Q= 31.0 <<< -------------------------------------------------------------------------- ------------------------------------------------------------------------ SOURCE >>> Pt 53.5 E=>45-E1b L=>90-Elb B=>TeeBch R=>TeeRun C=>CouPlg S=>SwgChk G=>GatVlv HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.2 - SUBMITTAL. ENGINEERS : SYMONS FIRE PROTECTION. (619) 588-6364. ADDRESS : 1050 Pioneer Way, Suite R, El Cajon CA 92020. DATE : 08-05-2009 FILE : C:\RESDEN43\09-118.RES JOB : ELICEIRI RESIDENCE 16'FT SLOPED PSI FIRE SPRINKLER HYDRAULIC GRAPH 100 ': 90 80 70 60 50 40 30 20 10 0 10 15 20 25 0 Supply Curve Static : 80.0. Resid : 79.0 Flow : 31.0 30 35 40 45 50 FLOW - Gpm Demand Curve Avi Pr : 79.0 @ 30 Req Pr : 53.5 @ 30 Pr Cush: 25.5 Copyright: Hydronics Engineering, 2002. 34119 Fremont Bi, Suite 609, Fremont, CA. 94555. (510) 487-9160. Fl Res 49 Pendent Fl Res 49 Recessed Pendent / F2 Fl Res 44 HSW Fl Res 44 Recessed HSW/F2 Fl Res 40 Recessed HSW/F2 , RFC 43 Fl Res 40 HSW Fl Res 49 CCP Pendent Bulletin 035 Rev.E Reliabl e Resdentl Sprnklers For Sloped Cei lings Guidelines for Listed Residential Sprinkler installations below Sloped Ceilings The installation guidelines cover Residential Sprinkler Models: Fl Res 49 Pendent Fl Res 49 Recessed Pendent/F2 Fl Res 44 HSW Fl Res 44 Recessed HSW/F2 Fl Res 40 HSW Fl Res 40 Recessed HSW/F2 Fl Res 49 CCP RFC 43 Flat Concealed Listings & Approva!s Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) NYC MEA 258-93-E UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents: US Patent number 6,516,893 Model Fl Res 49 Product Description for Fl Res Sprinklers Model Fl Res Pendent sprinklers are fast response sprinklers combining excellent durability, high sensitivity glass-bulb and low profile decorative design. The Fl Res Horizontal Sidewall sprinklers are equally attractive when above ceiling piping cannot be used. The 3mm glass-bulb pendent sprinklers, with a K Factor of 4.9 for pendent and 4.4 for horizontal sidewall, permit the efficient use of residential water supplies for sprinkler coverage in residential fire protection design. The low flow Fl Res sprinklers are specially engineered for fast thermal response to meet the sensitive fire protection application needs of the latest residential market standards (UL 1626 Standard *). Upon fire conditions, rising heat causes a sprinkler's heat-sensitive glass-bulb to shatter, releasing the waterway for water flow onto the deflector, evenly distributing the discharged water to control a fire. RFC 43 * Effective date July 12, 2002 The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Product Description for RFC 43 Model RFC43 Concealed Residential Sprinklers are fast response residential fusible solder link automatic sprinklers. Residential sprinklers differ from standard sprinklers primarily in their response time and water distribution patterns. Model RFC43 sprinklers discharge water in a hemispherical pattern below the sprinkler deflector. Residential distribution patterns are higher and generally contain a finer droplet size than standard sprinkler patterns. The combination of speed of operation and high discharge pattern required for residential sprinklers has demonstrated, in fire testing, an ability for controlling residential fires, and thereby providing significant evacuation time for occupants. The RFC43 Sprinkler provides the best form of fire protection by combining an attractive appearance and ½' (13mm) of cover adjustment for ease of installation. The small diameter cover plate is easily and positively attached and blends into the ceiling, concealing, the most dependable fire protection available, an automatic sprinkler system. The RFC43 is a UL Listed Residential Sprinkler to be installed in the residential portions of any Occupancy in accordance with NFPA 13, 13R, & 13D. The RFC43 can reduce the need for precise cutting of drop nipples. The threaded cover plate assembly can be adjusted without tools to fit accurately against the ceiling. The fire protection system need not be shut down to adjust or remove the cover plate assembly. Technical Data (Fl Res Sprinklers): Thermal Sensor: Nominal 3mm glass-bulb Sprinkler Frame: Brass Casting Sprinkler Pressure Rating: 175 psi Factory Hydrostatically Tested to 500 psi Thread Size : ½ NPT (R½) K Factor : 4.9 (Actual) - El Res 49 Pendent Sprinkler 4.4 (Actual) - Fl 'Res 44 HSW Sprinkler 4.0 (Actual) - Fl Res 40 HSW Sprinkler Density : Minimum .05 gpm/ft2 Technical Data (RFC 43): @ Thermal Sensor: 165°F Fusible Link Sprinkler Frame: Brass Machined Sprinkler Pressure Rating: 175 psi Factory Hydrostatically Tested to 500 psi ° Thread Size : ½' NPT (R½) ° K Factor : 4.3 (Actual) Density : Minimum .05 gpm/ft2 Application Model Fl Res and RFC 43 Sprinklers are. used for Residential Fire Protection according to UL 1626 Standard*. Be sure that orifice size, temperature rating, deflector style, cover plate and sprinkler type are in accordance with the latest published standards of The National Fire Protection Association or the approving Authority Having Jurisdiction. * Effective date July 12, 2002 2. Model Fl Res 49 Pendent & Fl Res 49 Recessed Pendent/Fl & Fl Res 49 CCP Pendent & RFC 43 Pendent Flat Concealed Sprinklers installed below Sloped 'Ceilings. Fl Res 49 Fl Res 49 Fl Res 49 COP Pendent Recessed Pendent / F2 Pendent RFC 43 RFC 43 Note: Fl Res 49 COP Pendent and RFC 43 sprinklers are not suitable for installation in ceilings which have positive pressure in the space above. 4. Model Fl Res 49 Pendent & Fl Res 49 Recessed Pendent/F2 installed below Sloped Ceiling. Technical Data Thread Max. Pressure Max. Ambient Temp. Actual I K Factor Sprinkler h Escutcheon Sprinkler l Identification Size psi (bar) °F (°C) I (metric) Length I I Number (SIN) I ½"NPT(R'/2) 175 (12) 100 (38) 4.9(69,94) 2.25" I (" F2 Adjustment) R3516 Table 1 - Aoolication Max. Sprinkler Spacing Along Slope (W) Width x ( L) Length It (m) Max. Slope of r3.7°) Pitch Max. Slope of (18.40) Pitch Mm. Flow Per Sprinkler gpm(Lpm) Head Pressure - psi (bar) Sprinkler Temp. Rating °F (°C) 155 (68) & 175 155°F (68°C) 175°F (790C°) 155°F (68°C) 175°F (79°C°) Mm. Flow Per Sprinkler Head gpm (Lpm)-- Pressure psi(bar) 12 x12(3,6x3,6) 13 (49) 13 (_ 7.0(0,48) 7.0(0,48) 13 (49) 7.0 (0,48) 14x14(4,3x4,3) 13(49) 13(49) 7.0(0,48) 7.0(0,48) 13(49) 16 x 16 (4,9 x 4,9) 13 49 13(49) 7.0(0,48) 7.0 (0,48) 13(49) E 17(64,3) 18(68,2) 0(0,48) 18x18(5,55,5) 12.0(0,83) 13.593L 17(64,3j_ 0(0,83) 20x20(6,1 x6,1) 20 (75,7) 21 (795L 16.7(1,15) 18.4 (1,i8) 20(75,7) 16.7(l.15) Model Fl Res 49 CCP Pendent installed below Sloped Ceiling. Technical Data Sprinkler Temp. CCP Assy; Temp. Max. Max. Ambient Actual I K Sprinkler Sprinkler Thread Size Rating °F (°C) Rating Pressure I Temp. I Factor Length Identification I Number (SIN) psi(bar)I_°F(°C)I_(metric) WNPT(R) _155 (68)I_135 _°F(°C) (57) 175 (12) _100(38) _4.9(69,94) _2.25 _I_I _R3516 I Table 2- ADolication Max. Sprinkler Spacing Along Slope (W) Width x ( L) Length ft (m) Max.Slopeof %2 (33.70 Pitch Max.Slope of /2 (18.4° Pitch Mm. Flow Per Sprinkler Head gpm(Lpm) Pressure psi (bar) Mm. Flow Per Sprinkler Head gpm(Lpm) Pressure psi(bar) 12x12(3,6x3,6) -14(53) 8.2(0,57) 13(49) 7.0(0,48) 14x14(4,3x4,3) 14(53) 8.2(0,57) 13(49) 7.0 0.48 16x16(4,9x4,9) 14(53) 8.2(0,57) 14(53) 8.2(0,56) 18 x 18 (5,5 x 5,5) 21(79,4) 18.4(1,27) 20x20(6,1 x6,1) 21(79,4) 18.4(1,27) Model RFC 43 Pendent Flat Concealed installed below Sloped Ceiling. Tethnical Data Tread Sprinkler Temp. Rating °F(°C) Coverplate j Temp. Rating I. Max. I Pressure IdentificationSize Max. Ambient Temp.I K °F(°C)I_(metric) I Actual Factor Max. _AdjustmentNumber Sprinkler (SIN)] W NPT(R½) _165(74) _°F(°C)I_psi(bar) _135(57) _175(12) 100(38)I_4.3(61,4) _RA0612 Table 3- Aoolication Max. Sprinkler Spacing Along Slope (W) Width x ( L) Length ft (m) Max.Slopeof %2 (33.70 Pitch Max.Slope of %2 (18.40 Pitch Mm. Flow Per Sprinkler Head gpm(Lpm) Pressure psi(bar) Mm. Flow Per Sprinkler Head gpm(Lpm) Pressure psi (bag -12x12(3,6x3,6) 18(68) 17.5(1,21) 13(49)- 14x 14(4,3x4,3) 18(68) 17.5 (1,21) 13(49) 10) 16 x 16(4,9 x 4,9) 18(68) 17.5 (1,21)____ 13(49) - 9.1(0,63)_ 18 x 18 (5,5 x 5,5) 21(79) 23.8(1,64) 20 x 20 (6,1 x 6,1) 21(79) 23.8 (1,64) 7. tqCC /Fire & Building I Products Papd response HOME FIRE SPRINKLER SYSTEM Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Series LFII Residential Horizontal Sidewall Sprinklers 4,2 K-factor General Description The Series LFII (1Y1334) Residential Horizontal Sidewall Sprinklers are decorative, fast response, frangible bulb sprinklers designed for use in residential occupancies such as homes, apartments, dormitories, and hotels. When aesthetics and optimized flow characteristics are the major con- sideration, the Series LFII (TY1334) should be the first choice. The Series LFII are to be used in wet pipe residential sprinkler systems for one- and two-family dwellings and mo- bile homes per NFPA 130; wet pipe residential sprinkler systems for resi- dential occupancies up to and includ- ing four stories in height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occu- pancy per NFPA 13. The Series LFII (TY1334) has a 4.2 (60,5) K-factor that provides the re- quired residential flow rates at reduced pressures, enabling smaller pipe sizes and water supply requirements. The recessed version of the Series LFII (TY1334) is intended for use in areas with finished walls. It employs .a two-piece Style 20 Recessed Escutch- eon. The Recessed Escutcheon pro- vides 1/4 Inch (6,4 mm) of recessed IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush mounting surface position. The adjust- ment provided by the Recessed Es- cutcheon reduces the accuracy to which the pipe nipples to the sprinklers must be cut. The Series LFII (TY1334) has been designed with heat sensitivity and water distribution characteristics provento help in the control of residen- tial fires and to Improve the chance for occupants to escape or be evacuated. WARNINGS The Series LFII (TY1334) Residential Horizontal Side wall Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing Jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing (heir fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler/Model Identification Number SIN TY1334 Page 1 of 8 JANUARY, 2006 TFP4IO Page 2 of 8 TFP4IO Components: 5 3 2 1 1 Frame WRENCH Button Assembly FLATS til Sealing Assembly Bulb Compression Screw Deflector * TOP-OF- 7/16' (11,1 mm) 2-7/8 DIA. DEFLECTOR NOMINAL MAKE-IN STYLE 20 (73,0 mm) . * Temperature rating is indicated on top of Deflector. CENTERLINE (11,1 mm) 1/2 NPT RECESSEDIJ OF WATERWAY 7/16" ESCUTCHEON END OF I(41,3 mm) ESCUTCHEON DEFLECTOR 2-1/4' I PLATE SEATING BOSS (57,2 mm) SURFACE RECESSED FIGURE 1 SERIES LFII (TY1334) RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS - 7/16±1/8" (11,1±3,2 mm) MOUNTING FACE OF SURFACE -J - SPRINKLER I FITTING I S TOP-OF- CLOSURE' __T DEFLECTOR - 1334 2-7/8" DIA. TT (73,0mm) 1/4 DIA • (11,1 mm) MOUNTING PLATE END-OF- DEFLECTOR BOSS I (3,2 mm) 1-3/8" (34,9 mm) 1/2" (12,7 mm) 1-1/8"(28,6mm) 1/4"(6,4mm) FIGURE STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE SERIES LFII (TY1334) RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER WRENCH RECESS (END "A" USED FOR 1Y1334) FIGURE 3 W.TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH TFP4IO Page 3 of 8 Technical Data Approvals: UL and C-UL Listed. NYC Approved under MEA 44-03-E. Maximum Working Pressure: 175 psi (12,1 bar) Discharge Coefficient: K = 4.2 GPM/ps1112 (60,5 LPM/bar112) Temperature Rating: 155°F/68C or 175F/79°C Finishes: White Polyester Coated, Chrome Plated, or Natural Brass Physical Characteristics: Frame ..............Brass Button ..............Bronze Sealing Assembly ........... Beryllium Nickel w/Teflont Bulb .........3 mm dia. Glass Compression Screw .....Bronze Deflector ...........Copper tDupont Registered Trademark Operation The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb allowing the sprinkler to activate and flow water. Design Criteria The Series LFll (TY1334) Residential Horizontal Sidewall Sprinklers are UL and C-UL Listed for installation in ac- cordance with the following criteria. NOTE When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that may be accept- able to the local Authority Having Ju- risdiction. System Type. Only wet pipe systems may be utilized. Hydraulic Design. The minimum re- quired sprinkler flow rate for systems designed to NFPA 13D or NFPA 13R are given in Table A, B, C, and D as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: The flow rates given in Tables A, B. C, and D for NFPA 13D and 13R as a function of temperature rating and the maximum allowable coverage area. A minimum discharge of 0.1 gpm/sq. ft. over the "design area" comprised of the four most hydraulically de- manding sprinklers for the actual coverage areas being protected by the four sprinklers. Obstruction To Water Distribution. Locations of sprinklers are to be in accordance with the obstruction rules of NFPA 13 for residential sprinklers. Operational Sensitivity. The sprin- klers are to be installed with an end-of- deflector-boss to wall distance of 1- 3/8 to 6 inches or in the recessed po- sition using only the Style 20 Re- cessed Escutcheon as shown in Figure 2. In addition the top-of-deflector-to-ceil- ing distance is to be within the range (Ref. Table A, B, C, or D) being hy- draulically calculated. Sprinkler Spacing. The minimum spacing between sprinklers is 8 feet (2,4 m). The maximum spacing be- tween sprinklers cannot exceed the width of the coverage area (Ref. Table A) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 16 feet for a 16 ft. x 20 ft. coverage area). Installation The Series LFll (TY1334) must be in- stalled in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm). A leak tight 1/2 inch NP T sprinklerjoint should be obtained with a torque of 7 to 14 ft. lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft.lbs. (28,5 Nm) of torque is to be used to install sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon Plate by under- or'over-tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. The Series LFll Horizontal Sidewall Sprinklers must be installed in ac- cordance with the following instruc- tions. Step 1. Horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of water- way perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the Deflector is to face towards the ceiling with the front edge of the De- flector parallel to the ceiling. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 3). With reference to Figure 1, the W-Type 6 Sprinkler Wrench is to be applied to the wrench flats. The Series LFII Recessed Horizontal Sidewall Sprinklers must be installed in. accordance with the following in- structions. Step A. Recessed horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of waterway perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the Deflector is to face towards the ceiling. Step B. After installing the Style 20 Mounting- Plate over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 4). With reference to Figure 1, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the wall has been in- stalled or the finish coat has been ap- plied, slide on the Style 20 Closure over the Series LFll Sprinkler and push the Closure over the MoUnting Plate until its flange comes in contact with the wall. (Continued on Page 8) Page 4 of TFP4 10 ELEVATION Maximum Maximum Coverage Spacing Minimum Flow () and Residual Pressure Area (a) Width x Length (b) Ft. x Ft. Ft. (m) Top-Of-Deflector- To- Ceiling: 4 to 6 Inches (100 to 150 mm) Top-Of-Deflector. To- Ceiling: 6 to 12 Inches (150 to 300 mri) (m x m) 155°F1680C 1750F/791C 155F/68°C 1750F/79C 12 x 12 12 12 GPM (45,4 LPM) 12 GPM (45,4 LPM) 13 GPM (49,2 LPM) 13 GPM (49,2 LPM) (3,7 x 3,7) (3,7) 8.2 psi (0,57 bar) 8.2 psi (0,57 bar) 9.6 psi (0,66 bar) 9.6 psi (0,66 bar) 14 x 14 14 14 GPM (53,0 LPM) 16 GPM (60,6 LPM) 17 GPM (64,3 LPM) 18 GPM (68,1 LPM) (4,3 x 4,3) (43) 11.1 psi (0,77 bar) 14.5 psi (100 bar) 16.4 psi (1.13 bar) 18.4 psi (127 bar) 16 x 16 16 16 GPM (60,6 LPM) 16 GPM (60,6 LPM) 18 GPM (68,1 LPM) 18 GPM (68,1 LPM) (4,9 x 4,9) (4,9) 14.5 psi (100 bar) 14.5 psi (1,00 bar) 18.4 psi (1,27 bar) 18.4 psi (1,27 bar) 16x 18 16 19 GPM (71,9 LPM) 19 GPM (71,9 LPM) 21 GPM '(79,5 -LPM) 21 GPM (79,5 LPM) (4,9 x 5,5) (4,9) 20.5 psi (141 bar) 20.5 psi (1,41 bar) 25.0 psi (1,72 bar) 25.0 psi (1,72 bar) 16x20 16 23.GPM(87,1 LPM) 23 GPM (87,1 LPM) 26 GPM. (98,4 LPM) 26 GPM (98,4 LPM) (4,9 x 6,1) (4,9) 30.0 psi (2,07 bar) 30.0 psi (2,07 bar) 38.3 psi (264 bar) 38.3 psi (2,64 bar) For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Width (backwall where sprinkler is located) x Length (horizontal throw of sprinkler). Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design Criteria Section for details. Sidewall sprinklers, where installed under a ceiling with a slope greater than 0 inch rise for a 12 inch run to a slope up to 2 inch rise for 12 inch run, must be located per one of the following: Locate the sprinklers at the high point of the slope and positioned to discharge down the slope. Locate the sprinklers along the slope and positioned to discharge across the slope. TABLE A NFPA 13D AND NFPA 13R WET PIPE HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII (TY1334) RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS FOR HORIZONTAL CEILING (Maximum 2 Inch Rise for 12 Inch Run) TFP4IO Page 5 of S 12" ELEVATION Minimum Flow (c) and Residual Pressure (I) Two sprInkler design with the sprinklers at the high point of the slope and positioned to discharge down the slope. Maximum Maximum Coverage Spacing Area (a) Ft. Width x Length (b) (m) Top-Of-Deflector- To- Ceiling: Top-Of-Deflector. To- Ceiling: Ft Ft (m x m) 4 to 6 Inches (100 to 150 mm) 6 to 12 Inches (150(0300mm) 155FI68C 175FI79°C 155°F168°C 175°FI79C 12 x 12 12 1 12 GPM (45,4 LPM) T 12 GPM (45,4 LPM) T 13 GPM (49,2 LPM) T 13 GPM (49,2 LPM) (3,7 x 3,7) (3,7) - 8.2 psi (0,57 bar) - 8.2 psi (0,57 bar) 9.6 psi (0,66 bar) - 9.6 psi (0,66 bar) 14 x 14 14 1 14 GPM (53,0 LPM) 1 14 GPM (53,0 LPM.) 1 17 GPM (64.3 LPM) 1 17 GPM (64.3 LPM) (4,3 x 4,3) (4,3) - 11.1 psi (077 bar) - 11.1 psi (0,77 bar) - 16.4 psi (1,13 bar) - 16.4 psi (1,13 bar) 16 x 16 16 1 16 GPM (60,6 LPM) 1 16 GPM (60,6 LPM) I . 18 GPM (68,1 LPM) 1 18 GPM (68,1 LPM) (4,9 x 4,9) (4,9)' - 14.5 psi'(l,OO'bar) - 14.5 psi (1,00 bar) - 18.4 psi (1,27 bar) - 18.4 psi (1,27 bar) 16 x 18 16 1 19 GPM (71,9 LPM) I 19 GPM (71,9 LPM) 1 21 GPM (79,5 LPM) 1 21 GPM (79,5 LPM) (4,9.x 5,5) (4,9) - 20.5 psi (1,41 bar) - 20.5 psi (1,41 bar) - 25.0 psi (1,72 bar) 25.0 psi (1,72 bar) 16 x 20 16 1 24 GPM (90,8 LPM) I 24 GPM (90,8 LPM) 1 26 GPM (98,4 LPM) I 26 GPM (98,4 LPM) (4,9 x 6,1) (4,9) - 32.7 psi (2,25 bar) - 32.7 psi (2,25 bar) - 38.3 psi (2,64 bar) - 38.3 psi (2,64 bar) For coverage area dimensions less than or between those Indicated, it Is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Width (backwall where sprinkler is located) x Length (horizontal throw of sprinkler). Requirement is based on minimum flow In GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design Criteria Section for details.. TABLE B NFPA 13D AND NFPA 13R WET PIPE HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII (TY1334) RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS FOR SPRINKLERS AT THE HIGH POINT OF THE SLOPE AND DISCHARGING DOWN THE SLOPE (Greater Than 2 Inch Rise for 12 Inch Run Up To 8 Inch Rise for 12 Inch Run) P age o TFP4IO 12" 4" MAXIMUM ELEVATION For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Width (backwall where sprinkler Is located) x Length (horizontal throw of sprinkler). Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design Criteria Section for details.. TABLE C NFPA 130 AND NFPA 13R WET PIPE HYDRAULIC DESIGN CRITERIA FOR THE SERIES LF!I (TY1334) RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS FOR SPRINKLERS LOCATED ALONG A SLOPE AND DISCHARGING ACROSS THE SLOPE (Greater Than 2 Inch Rise for 12 Inch Run Up To 4 Inch Rise for 12 Inch Run) Minimum Flow (C) and Residual Pressure (H)Two sprinkler design with the sprinklers located along the slope and positioned to discharge across the slope. Maximum Maximum (II!) Three sprinkler design when there are more than two sprinklers in a compartment and Coverage Spacing with the sprinklers located along the slope and positioned to discharge across the slope. Area (a) Ft. Width Length (b) (m).. Top-Of-Deflector- To- Ceiling: Top-Of-Deflector-To- Ceiling: (mx m 4 to 6 Inches (100 to 150 mm) 6 to 12 inches (150 to 300 mm) 155°F/680C 175°FI79C 155F/68°C 175°F179°C 12 x 12 12 II 16 GPM (60,6 LPM) II 16 GPM (60,6 LPM) II 18 GPM (68,1 LPM) II 18 GPM (68,1 LPM) (3,7 x 3,7) (3,7) 14.5 psi (100 bar) - 14.5 psi (1,00 bar) - 18.4 psi (1,27 bar) - 18.4 psi (1,27 bar) 14 x 14 14 II 16 GPM (60,6 LPM) 11 16 GPM (60,6 LPM) Ii 18 GPM (68,1 LPM) II 18 GPM (68,1 LPM) (4,3 x4,3) (4,3) 14.5 psi (1,00 bar) 14.5 psi (1,00 bar) 18.4 psi (1,27 bar) 18.4 psi (1,27 bar) 16 x 16 16 II 16 GPM (60,6 LPM) Ii 16 GPM (60,6 LPM) II 18 GPM (68,1 LPM) II 18GPM (68,1 LPM) (4,9 x 4,9) (4,9) 14.5 psi (1,00 bar) - 14.5 psi (1,00 bar) - 18.4 psi (127 bar) - 18.4 psi (1,21 bar) 16 x 18 16 II 22 GPM (83,3 LPM) Ii 22 GPM (83,3 LPM) 11 22 GPM (83.3 LPM) Ii 22 GPM (83,3 LPM) (4,9 x 5,5) (4,9) - 27.4 psi (1,89 bar) - 27.4 psi (1,89 bar) 27.4 psi (1,89 bar) - 27.4 psi (189 bar) 16 x 20 16 lii 23 GPM (87,1 LPM) III 23 GPM (87,1 LPM) III 26 GPM (98,4 LPM) iir 26 GPM (98,4 LPM) (4,9 x 6,1) (4,9) - 30.0 psi (2,07 bar) - 30.0 psi (2,07 bar) - 38.3 psi (2,64 bar) - 38.3 psi (2,64 bar) TFP4I0 Page 7of '12" 8" MAXIMUM ELEVATION For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Width (backwall where sprinkler is located) x Length (horizontal throw of sprinkler). Requirement is based on minimum flow In GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design Criteria Section for details.. TABLED NFPA 130 AND NFPA 13R WET PIPE HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII (TY1334) RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS FOR SPRINKLERS LOCATED ALONG A SLOPE AND DISCHARGING ACROSS THE SLOPE (Greater Than 4 Inch Rise for 12 Inch Run Up To 8 Inch Rise for 12 Inch Run) Minimum Flow (c) and Residual Pressure (HI) Three sprinkler design when there are more than two sprinklers in a compartment and with the sprinklers located along the slope and positioned to discharge across the slope. Maximum Maximum Coverage Spacing Area (a) Ft. Width x Length (b) (m) Top - To. Ceiling: Ft x Ft ' (rnxm) 4t061nches(lOOtol5Omm) 155F/68C 175FI79°C 12 x 12 12 III 16 GPM (60,6 LPM) 111 16 GPM (60,6 LPM) (3,7 x 3,7) (3,7) 14.5 psi. (1,00 bar) 14.5 psi (1,00 bar) 14 x 14 14 , III 16 GPM (60,6 LPM) IT 16 GPM (60,6 LPM) (4,3 x 4,3) (4,3) 14.5 psi (1,00 bar) 14.5 psi (1,00 bar) , - 16 x 16 ' 16 111 16 GPM (60,6 LPM) 111 ' 16 GPM (60,6 LPM) (4,9 x 4,9) (4,9) 14.5 psi (1,00 bar) 14.5 psi (1,00 bar) - 16x18 16 ' N/A ' N/A' (4,9 x 5,5) (4,9) . ' 16x20 16 N/A ' ' N/A ' (4,9x6,1). (4,9) Page 8 of 8 TFP4IO Care and Maintenance The Series LFII (TY1334) must be maintained and serviced in accord- ance with the following instructions: NOTES Absence of an Escutcheon Plate may delay the sprinkler operation in a fire situation. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection sys- tem must be obtained from the proper authorities and all personnel who may be affected by this action must be no- tified. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or. otherwise. altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulbor that has lost liquid from its bulb. (Ref. Installation Section). The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. NOTE The owner must assure that the sprin- klers are not used for hanging of any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire orinad- vertent operation may result. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been.subjectto misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Contact your local distributor for availability.. Sprinkler Assembly: Series LFII (TY1334), K=4.2, Residen- tial Horizontal Sidewall Sprinkler with (specify) temperature rating and (specify) finish, P/N (specify). 155FI68C or Chrome Plated .........PIN 51-211-9.155 155F168C White Polyester.........PIN 51.211-4-155 155F/68°c White (RAL9O1O) ............. PIN 51-211-3.155 155FI68C Natural Brass...........PIN 51-211-1-155 175FI79C or Chrome Plated .........PIN 51.211-9-175 175F/79C White Polyester ......... PIN 51-211-4-175 175F/79C White (RAL9o1O) ............. PIN 51-211-3-175 175F/79C Natural Brass ............ PIN 51-211-1-175 Eastern Hemisphere.sales only. Recessed Escutcheon: Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (spec-ify*). *Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tqCLI /Fire & Building / Products Technical Services: Tel: (800) 381-9312 I Fax: (800) 791-5500 Series TY-FRB 2.8,4.2,5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General, Description The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response - standard cover- age, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. tamed when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet 1FP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices.• The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TY1I3I - Upright 2.81K, 1/2"NPT TY1231 - Pendent 2.81K, 1/2"NPT 1Y2131 - Upright 4.21K, 1/2"NPT TY2231 - Pendent 4.2K, 1/2"NPT TY3131 - Upright 5.61K, 1/2"NPT TY3231 - Pendent 5.61K, 1/2"NPT TY4131 - Upright 8.0K, 3I4"NPT TY4231 - Pendent 8.0K, 3/4"NPT TY4831- Upright 8.0K, 1/2"NPT TY4931- Pendent 8.01K, 1/2"NPT Page 1 of 10 MARCH, 2007 T!P171 DEFLECTOR 2-7/8" (73,0 mm) DIA. ESCUTCHEON PLATE SEATING SURFACE 1/2" NPT 2- (55, SSP DEFLECTOR* H- 2-7/8" (73,0mm) DIA. 1/2" Page 2 ©fl 10 ESCUTCHEON PLATE SEATING SURFACE 2-1/4" (57,2 mm) 1-9116" (39,7 mm) SSP DEFLECTOR * TFPI7I 7/16" (11,1 mm) STYLE 10 or 20 NOMINAL RECESSED ssj MAKE-IN ESCUTCHEON PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Seating 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw FIGURE 1 QUICK RESPONSE SERIES TY.FRB UPRIGHT (TYII3I) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT 7/16" (11,1 mm) STYLE 10 or 20 NOMINAL RECESSED MAKE-IN ESCUTCHEON DEFLECTOR 7/16" ,mm) 1 1 (111 Ill II fl N MAKE-IN 2-3/16" NOMINAL WRENCH __ (55,6 mm) FLATS 1/2" NPT I ryV PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Seating 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 112 INCH NPT 7/16" (11,1 mm) NOMINAL MAKE-IN 1/2" NPT TFPI7I Pe 3 of 10 ESCUTCHEON PLATE SEATING SURFACE 2-3/16" (55,6 mm) 1-1/2" (38,1 mm) STYLE 10 or 20 RECESSED ssu' ESCUTCHEON DEFLECTOR 7/16" (11,1 mm) I MAKE-IN WRENC ____ (55,6 mm) 2-3/16" H __ NOMINAL I FLATS 4 1/2"NPT f SSP DEFLECTOR * F - 2-7/8" (73,0 mm) DIA. PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3-Sealing 4-Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2 -Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2" (12,7 mm) STYLE 30 or 40 PLATE SEATING NOMINAL RECESSED * SURFACE "" MAKE-IN ESCUTCHEON SSU NPT DEFLECTOR 2-5/16" NOMINAL 1/2" (58,7 mm) I ... ______ 1 6* 5 MAKE-IN 2-1/4" : 1-9 ____________ WRENCH 57,2 mm) .7 FLATS H (39,7 mm) SSP DEFLECTOR* 2-7/8 (73.0 mm) DIA. 3/4 NPT PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw . FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 314 INCH NPT *6 5 16w 4 (55,6 mm) CROSS UPRIGHT SECTION * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. T___ 2-1/4° (57,2 mm) 1-9/16° (39,7 mm) = OH S .-..--- ssP* DEFLECTOR Pace 4 of W TFPI7I 1/2" NPT 7/16" (11,1 mm) NOMINAL MAKE-IN Ssu * DEFLECTOR PENDENT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector 2 - Button Assembly 5 - Compression Screw FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A and B for complete approval information including corro- sion resistant status.) Maximum Working Pressure Refer to Table C. Discharge Coefficient K = 2.8 GPM/psi112 (40,3.LPM/barl'2) K = 4.2 GPM/psil'2 (60,5LPM/barl'2) K = 5.6 GPM/p5i112 (80,6 LPM/barl'2) K = 8.0 GPM/p5i112 (115,2 LPM/bar112) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ...............Glass Compression Screw .....Bronze Deflector .......Copper/Bronze Bushing (K=2.8) .......Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. .4- Page 13 of TFPI7I SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB LIQUID NATURAL BRASS i CHROME PLATED I WHITE OLYESTER LEAD COATED 5.6 1/2" PENDENT (TY3231) and UPRIGHT (TY3131) 135F/57C Orange 1,2,3,4,5,6,7 1,2,3,5 155°F168°C Red 175°F/79°C Yellow 200°F/93C Green 286°F/141°C Blue NPT 135iI57C Orange 1,2,4, 5 N/A RECESSED PENDENT (TY3231)* Figure 10 155°F/68°C Red 175°F/79°C Yellow 200FI93C Green RECESSED PENDENT (TY3231) Figure 11 135°F157°C Orange I I I 1,2,3,4, 5 I I 1,2,4,5 Green N/A 155°F/68°C Red 175FI79C Yellow 200°F/93°C 8.0 3/4,, PENDENT (TY4231) and UPRIGHT (TY4131) 135°F/57°C Orange 1,2, 3, 4, 5, 6, 7 1,2,5 155°F/68°C Red 175°F/79C Yellow 200°F/93C Green 286°F/141C Blue NPT RECESSED PENDENT (TY4231)* Figure 12 135°F/57C Green 1,2,4,5 N/A 155°F/68°C Orange 175°F/79°C Red 200°F/93°C Yellow 135°F/57°C Orange 1, 2, 3, 4, 5 N/A RECESSED PENDENT (TY4231)** Figure 13 155°F/68C Red 175°F179°C Yellow 2ooF/g3°C Green 8.0 1/2" NPT PENDENT (TY4931) and UPRIGHT (TY4831) 135°F/57C Orange 1,2,4,5,6 1, 2.5 155°F/68°C Red 17579C Yellow 200F/93°C I Green 286°F/141C Blue NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k104) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2 NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2 NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS TFPI7I Pe 7 of 10 SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD BRASS PLATED POLYESTER COATED PENDENT (TY3231) and 2.8 UPRIGHT (1Y3131) 175 PSI (12,1 BAR) N/A 1/2" RECESSED PENDENT NPT (1Y323) PENDENT (TY4231) and 4.2 UPRIGHT (TY4131) 175 PSI (12,1 BAR) N/A RECESSED PENDENT NPT (1Y4231) PENDENT (TY3231) and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 5.6 UPRIGHT (1Y3131) OR 1/2" 175 PSI (12,1 BAR) RECESSED PENDENT NPT (TY3231) (SEE NOTE 1) N/A PENDENT (TY4231) and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 8.0 UPRIGHT (1Y4131) 3/4" RECESSED PENDENT NPT (TY4231) N/A 80 PENDENT (TY4931) 1/2" and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) NPT UPRIGHT (TY4831) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and ,the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE Installation The Series TY-FRB Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57C to 3/32 inch (2,4 mm) for the 286F/141C temperature ratings. A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft. lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained.with a torque of 10 to 20 ft. lbs. (13,4 to 26,8 Nm). A maximum of 30 ft. lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 14). With reference to Figures 1, 2, 3, 4, and 5, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 15). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed Page 8 of 10 2-7/8' DIA. 5/8±1/4" (73,0 mm) I 3/4" (19.1 mm) (159±6,4 mm) 2-1/4" DIA. I 1/4(6,4 mm) I FACE OF MOUNTING PLATE I FITTING I 1/8" 2mm SPRINKLER MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 13/16 (20,6 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8"OIA. 5/8±1/4' (73,0 mm) I 3/40(19.1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) I FACE OF MM) MOUNTING SPRINKLER PLATE I FITTING 1/8" I (3,2 mm) MOUNTING/ ..I.. t t SURFACE SERIES 1-1/4"(31,8 mm)1 CLOSURE TYFRB 3/4"(19,1 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT TFPI7I - 2-7/8" DIA. (73.0 mm) 1/2±1/8" I 1/2'(12,7mm) E (12,7±3,2 mm) 2-1/4" DIA. I 1/4" (6,4 mm) 1 I FACE OF (57.2 MM) ,-' MOUNTING I II SPRINKLER PLATE FITTING I 1/8" (3,2 mm) MOUNTING 1. I \ II SURFACE I CLOSURE SERIES '(33,3 mm) TY-FRB 1-1116"(27,0 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. - I (73,0 mm) 1/2±1/8" I 1/2(12,7mm) r (12,7±3,2 mm) 2-1/4" DIA. I 1/4"(6,4 mm) I FACE OFq R "' (572mm) MOUNTING I SPRINKLE PLATE I 1/8" I FITTING (32mm) MOUNTIN SURFACESERIES 1-1/4"(31,8mm) CLOSURE TYFRB 1"(25,4 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non-operation in the event of a fire or inadvertent opera- tion may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- TFPI7I - 2-7/8 DIA. 5/8±1/4" (73,0 mm) 3/4(19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) (57 FACE OF 2mm) MOUNTING SPRINKLER PLATE FITTING Jmm)ê U MOUNTING SURFACE SERIES 1-1/4"(31,8 mm) CLOSURE TY-FRB 3/4(19,1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6.4 mm) FACE OF (57,2 mm) MOUNTING PLATE SPRINKLER FITTING 1(8" --I ____ __ _ __ ____________ (3,2 mm) __ _ _ I ___ __ ____ MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TYFRB 13/16"(20,6 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT Page of 10 * 2-7/8" DIA. 1/2±1/8" 1/2" (12,7 (73,0 mm) (12,7t3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) I FACE OF [_57.2 mm) MOUNTING # 1/8" I SPRINKLER PLATE I FITTING (32 mm) I \ MOUNTING I SURFACE SERIES 1-1/4"(31,8 mm) CLOSURE TY.FRB 1" (25,4 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. —H 1/2" (12,7 mm) 1/2±1/8" (73,0 mm) r (12,7±3,2 mm) - 2-1/4" DIA. 1/4"(6,4 mm) FACE OF (57,2 mm) MOUNTING I SPRINKLER PLATE FITTING 1/8" __ (3,2 mm) I \ MOUNTING SURFACE CLOSURE SERIES 1-5/16"(33,3 mm) TY.FRB 1-1/16" (27,0 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH Inspection Service in accordance with local, requirements and/or national codes.