HomeMy WebLinkAbout5050 AVENIDA ENCINAS; STE 160; AS090026; Permit9/22/21, 4:04 PM AS090026 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS090026 5050 AVENIDA Job Address: Status: ISSUED ENCINAS Permit Type: SPRINK Applied 3/27/2009 Parcel No: 2100903600 Approved: 3/27/2009 Lot #: 0 Reference No.: Issued: 3/27/2009 PC #: Inspector: Project Title: SPEC SUITE 160 T.I. FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: WESTERN FIRE PROTECTION 13630 DANIELSON P0 WAY CA 858-513-4949 Owner: COGNAC CARLSBAD PACIFICA L L C C/P PATRICK COFFEY 4 EMBARCADERO CTR #2700 SAN FRANCISCO CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 130 0 130 0 1/1 Bulletin hiM Model Recessed R liable Sprinkler ) The Most Compact, Attractive and Easily Installed Sprinkler Ever Designed. Features 1½" Total adjustment provided by adjustable inlet versions. ½" Total adjustment provided by economical standard inlet version Adjustable inlet version available with either 1" NFl male or female threads eliminating costly reducing coupling. Small diameter escutcheon. Available in brass, chrome or white finish. Multiple orifice sizes for design flexibility. Listed by Underwriters Laboratories Inc. & Underwriters' Laboratories of Canada. Approved by Factory Mutual Research Corp. & Loss Prevention Council, NYC BS&A No. 587-75-SA. Today's modern buildings demand that a sprinkler not only provide the best fire protection but also achieve an attractive appearance. Reliable's Model G Recessed Sprinkler meets both criteria. It combines the fire fighting capability of a proven sprinkler with the smallest practi- cable recessing unit. Its small profile does not disrupt the overhead aesthetics, and yet one vertical glance upward gives a visual assurance of the finest in fire protection, an automatic sprinkler system. The Model G Recessed Sprinkler's threaded two—piece construction makes initial, field installation a very easy task. It allows ceilings panels to be removed without shutting down the fire protection thus facilitating mainte- nance of above ceiling services. The adjustable one inch NPT inlet versions have one and one half inches of adjustment which eliminates both the normally required reducing coupling and the need to accurately cut drop nipples. This sprinkler can be adjusted after the ceiling is in place and even while the system is pressurized eliminating the final corrections to pipe hangers or ceil- ings that might otherwise be required. The Reliable Model G Automatic Sprinkler is the heart of the Recessed Sprinkler. This sprinkler utilizes the center strut solder in compression principle of construc- tion. The fusible alloy, captured in the cylinder of a small solder capsule by a stainless steel ball, acts as the-trigger of the sprinkler. When the fusible alloy melts, the sprin- klers operating parts spring free from the sprinkler clear- ing the waterway and allowing the deflector to distribute the discharging water. The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York10552 AOD 3/16 FOR DUALE ON j/r 7/I6 & I7,'JZ' 00117CC ç .1'-----------El lT 4 .- ( ,/2• ENCUTCREON J) 0JUSfl4CN1 DIIACNSONS IN PARENDICSIS III MXNGETERS Sprinkler Maximum Ceiling Classification Rating Temperature °F "C "F "C Ordinary 135 57 100 38 Ordinary 165 74 100 38 Intermediate 212 100 150 66 Standard Sprinkler Finishes* Escutcheon Bronze Brass Bronze White Painted Chrome Bright Chrome Bright Chrome Bright Chrome Satin Chrome Bright White Painted Bright Brass Plated (1) Bright Brass Plated Black Plated Black Plated White Painted (2) Polyester Coated Polyester Coated (2) pecial Finishes upon request. (1 Only frame, deflector and cap are plated. (2) Only frame and deflector are painted or coated, operating parts are chrome plated. UL Listed and MEA Approved only. Sprinkler Inlet Total Adjustment * Nominal Orifice K Factor U.S. Metric Thread Approval Organizations Non-Adjustable 1/2" 1/2"(15mm) 5.62 81.0 1/2"NPT(R1/2) 1,2,3,4,5 Non-Adjustable 1/2" /16" 4.24 61.0 1/2" NPT (R1/2) 1,3,4 Non-Adjustable 1/2" 3/8" 2.82 40.6 1/2" NPT (R1/2) 1,3,4 Non-Adjustable 1/2" 17/32" 7.96 114.7 1/2" NPT (R1/2) 1,3 Adjustable 11/2" 1/2" 5.53 79.7 1" NPT Male or Female 1,2,3,4 Adjustable 11/2" /16' (1) 4.24 61.0 1" NPT Male or Female 1,3,4 Adjustable 11/2" 3/8" 2.75 39.2 1" NPT Male or Female i Adjustable 11/2" 15mm 553 79.7 R Male or Female 5 *Sprinkler escutcheon provides ½" of the total adjustment. Adjustable inlets, when used, provide 1" ot tne total adjustment. (1) Identified by pintle extending above the deflector ._ NPT Threads per ANSI B2.1 Ri Threads per ISO 7/1-1982 (BS 21:1973) Approval Organizations Ordering Information Specify 1. Temperature Rating 2. Nominal Orifice 3. Sprinkler Finish 4. Escutcheon Finish 1.Underwriters Laboratories Inc. 2. Factory Mutual Research Corp. Light Hazard Occupancies-No Limitations Ordinary Hazard Occupancies-Groups 1&2, Wet Systems Only Underwriters Laboratories of Canada NYC BS & A No. 587-75-SA Loss Prevention Council XLH, OHI and OHII Occupancies Only 6. NYC MEA 258-93-E 5. Sprinkler Type: Either Non-Adjustable Inlet (Fig.1) Note: Unless otherwise indicated, ordinary hazard approvals are 1" Male Adjustable Inlet (Fig.2) without limitations. 7/16" & 3/8" orifice sprinklers are limited to light 1" Female Adjustable Inlet (Fig.3) hazard occupancies. ½" NPT Non-Adjustable Inlet Figure 1 SSTW ICE OR CLVOR -p-. fl1r l _ll!li1j jjllILj COUPOIG RfDUCER-. PACE OF ernNG TO r 10Cr 404*. FACE IC CEILING AtuusrlJrnr 54(0 CEILING • 03 VI up 455(4010' CLILING 112- CSCUTCHE1W ---I 1" NPT Male-Adjustable Inlet Figure 2 2. DROP NIPftE = A- NOTE - SNPtFC424LC INLET I DROP NIPPLE ID C lOIRE 404*. AOJUSTVCNI 0/MEN SOON SI'NINILL(R CE/LONG 03 V' • CUP *55(44807 /2 / 1" NPT Female-Adjustable Inlet Figure 3 Product Description and Installation The Reliable Model C Recessed Sprinkler has been designed with ease of installation in mind. A choice of three inlets with up to one inch adjustment coupled with the ½" escutcheon adjustment enables most system to be installed using pre-cut drop nipples. The adjustment can be accomplished after the ceiling installation and while the system is pressurized thereby providing sprin- kler protection before construction is completed. The Non-Adjustable inlet version (Figure 1) consists of the Reliable Model G Sprinkler with an attached cup recessed in the ceiling. A ceiling hole of 2 1/4" diameter is recommended. The Adjustable inlet version uses the same sprinkler as the Non-Adjustable inlet type except that 1 of additional adjustment is provided by a telescoping sprinkler inlet section that threads in or out of a stationary Coupling Reducer (either 1" male or 1"female) as shown in figures 2 or 3. The Sprinkler-Cup assembly comes attached to the inlet Coupling Reducer and is retained from separa- tion past its maximum adjustment length by a snap ring. This combination is simply installed after the system drop nipple, elbow or tee has been "roughed in" to the dimensions shown in figures 2 or 3. Wrenching means are provided by hex flats on the coupling reducer as depicted in the figures-do not wrench on any other part of the sprinkler. After the ceiling tiles have been cut and installed in place (a 21/4"diameter hole is recommended), the sprinkler can be adjusted using the RC-1 Concealed Wrench. When using the wrench in this application, however, do not over-torque beyond the adjustment stops. Figure 4 shows a ½" NPT non-adjustable inlet sprin- kler, with the attached sprinkler cup combination in- serted into the special Reliable Model RC-1 Installation Wrench. This wrench must be used. The wrenching pads of the sprinkler easily slip into the rectangular cut-outs of the wrench as the outside diameter locates the threaded cup. A ½" drive ratchet can then be used for installation and tightening. Figure 5 shows the removal of the wrench. Care should be taken during this procedure to avoid hitting the de- flector with the wrench. The wrench should be lowered until it clears the threaded cup, and then moved horizon- tally to clear the sprinkler. The installation is completed by threading the escutcheon on until it contacts the ceiling. To avoid leaving smudge marks on the ceiling, the Reliable Model FEA Flush Sprinkler Escutcheon Wrench should be used. See Bulletin 205 for details. Note: Use hex wrench flats on Coupling Reducer to tighten Adjustable Sprinkler into fittings. Do not use RC-1 Wrench for this purpose. Do not install the Model C Recessed Sprinkler in ceilings which have positive pressure in the space above. :...t Figure 4 Figure 5 3. Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler 'alarm switches Water flow detectors Deluge valves Detector check valves Check valves Supertrol electrical system Sprinkler emergency cabinets Sprinkler Wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 70 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc.' Recycled Paper R ® (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax Revision lines indicate updated or new data. (914) 668-3470 Corporate Offices http://www.reliablesprinkier.com Internet Address E.G. Printed in U.S.A. 3/99 P/N 9999970006