HomeMy WebLinkAbout5050 AVENIDA ENCINAS; STE 160; AS090026; Permit9/22/21, 4:04 PM AS090026 Permit Data
City of Carlsbad
Sprinkler Permit
Permit No: AS090026
5050 AVENIDA
Job Address: Status: ISSUED
ENCINAS
Permit Type: SPRINK Applied 3/27/2009
Parcel No: 2100903600 Approved: 3/27/2009
Lot #: 0
Reference No.: Issued: 3/27/2009
PC #: Inspector:
Project Title: SPEC SUITE 160 T.I. FIRE SPRINKLER PLAN CHECK &
INSPECTIONS
Applicant:
WESTERN FIRE PROTECTION
13630 DANIELSON
P0 WAY CA
858-513-4949
Owner:
COGNAC CARLSBAD PACIFICA L L C
C/P PATRICK COFFEY
4 EMBARCADERO CTR #2700
SAN FRANCISCO CA
Fees ($) Add'l Fees ($) Total ($) Balance ($)
130 0 130 0
1/1
Bulletin hiM
Model
Recessed R liable
Sprinkler
)
The Most Compact,
Attractive and Easily
Installed Sprinkler
Ever Designed.
Features
1½" Total adjustment provided by
adjustable inlet versions.
½" Total adjustment provided by
economical standard inlet version
Adjustable inlet version available with
either 1" NFl male or female threads
eliminating costly reducing coupling.
Small diameter escutcheon.
Available in brass, chrome or white finish.
Multiple orifice sizes for design flexibility.
Listed by Underwriters Laboratories
Inc. & Underwriters' Laboratories of
Canada. Approved by Factory Mutual
Research Corp. & Loss Prevention
Council, NYC BS&A No. 587-75-SA.
Today's modern buildings demand that a sprinkler not
only provide the best fire protection but also achieve an
attractive appearance. Reliable's Model G Recessed
Sprinkler meets both criteria. It combines the fire fighting
capability of a proven sprinkler with the smallest practi-
cable recessing unit. Its small profile does not disrupt the
overhead aesthetics, and yet one vertical glance upward
gives a visual assurance of the finest in fire protection,
an automatic sprinkler system.
The Model G Recessed Sprinkler's threaded two—piece
construction makes initial, field installation a very easy
task. It allows ceilings panels to be removed without
shutting down the fire protection thus facilitating mainte-
nance of above ceiling services. The adjustable one inch
NPT inlet versions have one and one half inches of
adjustment which eliminates both the normally required
reducing coupling and the need to accurately cut drop
nipples. This sprinkler can be adjusted after the ceiling
is in place and even while the system is pressurized
eliminating the final corrections to pipe hangers or ceil-
ings that might otherwise be required.
The Reliable Model G Automatic Sprinkler is the heart
of the Recessed Sprinkler. This sprinkler utilizes the
center strut solder in compression principle of construc-
tion. The fusible alloy, captured in the cylinder of a small
solder capsule by a stainless steel ball, acts as the-trigger of the sprinkler. When the fusible alloy melts, the sprin-
klers operating parts spring free from the sprinkler clear-
ing the waterway and allowing the deflector to distribute
the discharging water.
The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York10552
AOD 3/16 FOR DUALE ON
j/r 7/I6 & I7,'JZ' 00117CC
ç .1'-----------El
lT
4 .-
( ,/2• ENCUTCREON
J) 0JUSfl4CN1
DIIACNSONS IN PARENDICSIS III MXNGETERS
Sprinkler Maximum Ceiling
Classification Rating Temperature
°F "C "F "C
Ordinary 135 57 100 38
Ordinary 165 74 100 38
Intermediate 212 100 150 66
Standard
Sprinkler
Finishes*
Escutcheon
Bronze Brass
Bronze White Painted
Chrome Bright Chrome Bright
Chrome Bright Chrome Satin
Chrome Bright White Painted
Bright Brass Plated (1) Bright Brass Plated
Black Plated Black Plated
White Painted (2) Polyester Coated
Polyester Coated (2)
pecial Finishes upon request. (1 Only frame, deflector and cap are plated.
(2) Only frame and deflector are painted or coated, operating parts
are chrome plated. UL Listed and MEA Approved only.
Sprinkler Inlet
Total
Adjustment * Nominal Orifice
K Factor
U.S. Metric Thread
Approval
Organizations
Non-Adjustable 1/2" 1/2"(15mm) 5.62 81.0 1/2"NPT(R1/2) 1,2,3,4,5
Non-Adjustable 1/2" /16" 4.24 61.0 1/2" NPT (R1/2) 1,3,4
Non-Adjustable 1/2" 3/8" 2.82 40.6 1/2" NPT (R1/2) 1,3,4
Non-Adjustable 1/2" 17/32" 7.96 114.7 1/2" NPT (R1/2) 1,3
Adjustable 11/2" 1/2" 5.53 79.7 1" NPT Male or Female 1,2,3,4
Adjustable 11/2" /16' (1) 4.24 61.0 1" NPT Male or Female 1,3,4
Adjustable 11/2" 3/8" 2.75 39.2 1" NPT Male or Female i
Adjustable 11/2" 15mm 553 79.7 R Male or Female 5
*Sprinkler escutcheon provides ½" of the total adjustment. Adjustable inlets, when used, provide 1" ot tne total adjustment.
(1) Identified by pintle extending above the deflector
._
NPT Threads per ANSI B2.1
Ri Threads per ISO 7/1-1982 (BS 21:1973)
Approval Organizations
Ordering Information
Specify
1. Temperature Rating
2. Nominal Orifice
3. Sprinkler Finish
4. Escutcheon Finish
1.Underwriters Laboratories Inc.
2. Factory Mutual Research Corp.
Light Hazard Occupancies-No Limitations
Ordinary Hazard Occupancies-Groups 1&2, Wet Systems Only
Underwriters Laboratories of Canada
NYC BS & A No. 587-75-SA
Loss Prevention Council
XLH, OHI and OHII Occupancies Only
6. NYC MEA 258-93-E
5. Sprinkler Type: Either
Non-Adjustable Inlet (Fig.1) Note: Unless otherwise indicated, ordinary hazard approvals are
1" Male Adjustable Inlet (Fig.2) without limitations. 7/16" & 3/8" orifice sprinklers are limited to light
1" Female Adjustable Inlet (Fig.3) hazard occupancies.
½" NPT Non-Adjustable Inlet
Figure 1
SSTW ICE OR CLVOR -p-. fl1r
l _ll!li1j jjllILj
COUPOIG RfDUCER-.
PACE OF ernNG TO
r 10Cr 404*.
FACE IC CEILING
AtuusrlJrnr
54(0
CEILING • 03 VI
up
455(4010'
CLILING
112- CSCUTCHE1W ---I
1" NPT Male-Adjustable Inlet
Figure 2
2.
DROP NIPftE
= A- NOTE
- SNPtFC424LC
INLET I
DROP NIPPLE ID C lOIRE 404*. AOJUSTVCNI 0/MEN SOON
SI'NINILL(R
CE/LONG 03 V' • CUP *55(44807
/2
/
1" NPT Female-Adjustable Inlet
Figure 3
Product Description and Installation
The Reliable Model C Recessed Sprinkler has been
designed with ease of installation in mind. A choice of
three inlets with up to one inch adjustment coupled with
the ½" escutcheon adjustment enables most system to
be installed using pre-cut drop nipples. The adjustment
can be accomplished after the ceiling installation and
while the system is pressurized thereby providing sprin-
kler protection before construction is completed.
The Non-Adjustable inlet version (Figure 1) consists of
the Reliable Model G Sprinkler with an attached cup
recessed in the ceiling. A ceiling hole of 2 1/4" diameter
is recommended.
The Adjustable inlet version uses the same sprinkler as
the Non-Adjustable inlet type except that 1 of additional
adjustment is provided by a telescoping sprinkler inlet
section that threads in or out of a stationary Coupling
Reducer (either 1" male or 1"female) as shown in figures
2 or 3. The Sprinkler-Cup assembly comes attached to
the inlet Coupling Reducer and is retained from separa-
tion past its maximum adjustment length by a snap ring.
This combination is simply installed after the system drop
nipple, elbow or tee has been "roughed in" to the
dimensions shown in figures 2 or 3. Wrenching means
are provided by hex flats on the coupling reducer as
depicted in the figures-do not wrench on any other part
of the sprinkler. After the ceiling tiles have been cut and
installed in place (a 21/4"diameter hole is recommended),
the sprinkler can be adjusted using the RC-1 Concealed
Wrench.
When using the wrench in this application, however, do
not over-torque beyond the adjustment stops.
Figure 4 shows a ½" NPT non-adjustable inlet sprin-
kler, with the attached sprinkler cup combination in-
serted into the special Reliable Model RC-1 Installation
Wrench. This wrench must be used. The wrenching pads
of the sprinkler easily slip into the rectangular cut-outs of
the wrench as the outside diameter locates the threaded
cup. A ½" drive ratchet can then be used for installation
and tightening.
Figure 5 shows the removal of the wrench. Care should
be taken during this procedure to avoid hitting the de-
flector with the wrench. The wrench should be lowered
until it clears the threaded cup, and then moved horizon-
tally to clear the sprinkler. The installation is completed
by threading the escutcheon on until it contacts the
ceiling. To avoid leaving smudge marks on the ceiling,
the Reliable Model FEA Flush Sprinkler Escutcheon
Wrench should be used. See Bulletin 205 for details.
Note:
Use hex wrench flats on Coupling Reducer to tighten
Adjustable Sprinkler into fittings. Do not use RC-1
Wrench for this purpose.
Do not install the Model C Recessed Sprinkler in
ceilings which have positive pressure in the space
above.
:...t
Figure 4 Figure 5
3.
Reliable...For Complete Protection
Reliable offers a wide selection of sprinkler components. Following are some of the many
precision-made Reliable products that guard life and property from fire around the clock.
Automatic sprinklers
Flush automatic sprinklers
Recessed automatic sprinklers
Concealed automatic sprinklers
Adjustable automatic sprinklers
Dry automatic sprinklers
Intermediate level sprinklers
Open sprinklers
Spray nozzles
Alarm valves
Retarding chambers
Dry pipe valves
Accelerators for dry pipe valves
Mechanical sprinkler alarms
Electrical sprinkler 'alarm switches
Water flow detectors
Deluge valves
Detector check valves
Check valves
Supertrol electrical system
Sprinkler emergency cabinets
Sprinkler Wrenches
Sprinkler escutcheons and guards
Inspectors test connections
Sight drains
Ball drips and drum drips
Control valve seals
Air maintenance devices
Air compressors
Pressure gauges
Identification signs
Fire department connection
The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research
Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 70 years, and are installed and serviced by the most highly qualified and
reputable sprinkler contractors located throughout the United States, Canada and foreign countries.
Manufactured by
The Reliable Automatic Sprinkler Co., Inc.' Recycled Paper
R ® (800) 431-1588 Sales Offices
(800) 848-6051 Sales Fax Revision lines indicate updated or new data.
(914) 668-3470 Corporate Offices
http://www.reliablesprinkier.com Internet Address E.G. Printed in U.S.A. 3/99 P/N 9999970006