HomeMy WebLinkAbout6060 AVENIDA ENCINAS; ; AS080065; Permitulty ot uarlsbacl Sprinkler Permit Permit No: AS080065 6060 AVENIDA Job Address: Status: ISSUED ENCINAS Permit Type: SPRINK Applied 4/25/2008 Parcel No: 2110303100 Approved: 5/13/2008 Lot #: 0 Reference No.: Issued: 5/13/2008 PC #: Inspector: Project Title: PLAYWERX FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: CPS FIRE PROTECTION, INC. 417 VERNON WY EL CAJON, CA 619-726-0183 Owner: RUBY CHARLES E&SANDRA P 0 BOX 805 CARDIFF CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0° IlProducts Fire & Building oem Customer Service/Sales: Technical Services: Tel: (800) 381.9312/ Fax: (800) 791-5500 Tel: (414) 570-5000/(800) 558-5236 Fax: (414) 570-5010/ (800) 877-1295 Series TY-FRB 281 42,5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response standard cover- age, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 112 inch (12,7 mm) of - recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustmentfrom the flush pendent position, or a two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- feet/on Association, in addition to the standards of.any other authorities hav- ing jurisdiction. Failure to do so may impair the integrity of these devices. The owner is responsible for ma 11am- ing their fire protection system and de- vices in proper operating condition.- The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Model/Sprinkler Identification Numbers TY1131 - Upright 2.6K, 1/2"NPT 1Y1231 - Pendent 2.81K, 1/2"NPT TY2131 - Upright 4.2K, 1/2"NPT TY2231 - Pendent 4.2K, 1/2"NPT 1Y3131 - Upright 5.6K, 1/2"NPT 1Y3231 - Pendent 5.61K, 1/2"NPT 1Y4131 - Upright 8.01K, 3/4"NPT TY4231 - Pendent LOK, 3/4"NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A for complete approval information including corrosion resis- tant status.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 2.8 GPM/psi"2 (40,3 LPM/bar1l2) K = 4.2 GPM/p5i1/2 (60,5 LPMIbar1I2) K = 5.6 GPM/psi1/2 (80,6 LPM1bar112) K = 8.0 GPM/ps1112 (115,2 LPMIbar"2) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ............Bronze Button ........Brass/Copper Sealing Assembly .......... Beryllium Nickel wflèflont Bulb ..............Glass Compression Screw .....Bronze Deflector .......Copper/Bronze Bushing (K=2.8) .......Bronze 4- Page 1 of 8 APRIL, 2003 TFPI7I Page 2of8 TFPI7I ESCUTCHEON 7/16' (11,1 mm) STYLE 10 or 20 PLATE SEATING ** NOMINAL RECESSED SURFACE 1/2. MAKE-IN ESCUTCHEON SSU NPT DEFLECTOR T_ 7/16' mm) I 2-1/4 11,1 I (57 mm) NOMINAL MAKE-IN i 1-9/16' 2-3/16' ,2 _______ . I (39,7 mm) J WRENCH (55,6 mm) FLATS SSP DEFLECTOR * 2-7' 3,0 mm) D 112'NPT ** PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION - Frame 3- Sealing 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5-Compression 7- BuShing orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 QUICK RESPONSE SERIES 1Y-FRB UPRIGHT (TY1I3I) AND PENDEN7(TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT ESCUTCHEON PLATE SEATING 1 " SURFACE NPT I (556 mm) 7/16'(11,1 mm) NOMINAL MAKE-IN STYLE 10 or 20 RECESSED SSU* ESCUTCHEON DEFLECTOR NOMINAL WRENCH (55,6 mm) !k FLATS L_ 2-7/8' (73.0 mm) DIk 112' NPT' RECESSED PENDENT UPRIGHT CROSS SECTION 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 5- Compression orifice seat on frame. Screw ... Pipe thread connecbons per ISO 7/1 can be provided on special request. SSP DEFLECTOR* PENDENT I - Frame 3-Sealing 2- Button Assembly Ii" FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (Tr'2131) AND PENDENT(TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT STYLE 10 or 20 RECESSED ESCUTCHEON SSU * DEFLECTOR WRENC FLATS /8' (73,0 mm) DIA. —1 7/16' 11,1 mm) 4OMINAL MAKE-IN 2-3/16 __.J. (55,6 mm) 6* 1/2' NPT** STYLE 30 or 4.0 RECESSED ESCUTCHEON SSU * DEFLECTOR I WRENCH FLATS 7/8' (73,0 mm) DIA. _J ESSED PENDENT :1 I 6* im) UPRIGHT CROSS SECTION TFPI7I Page 3of8 ESCUTCHEON 7/16 (11,1 mm) PLATE SEATING 1/2 ** NOMINAL SURFACE NPT MAKE-IN _F_ 2-3/16' 11! (55,6 mm) 1- SSPDEFLECTOR* 2- (38, PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION - Frame 3 Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw 'Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY313 1) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2' (12,7 mm) PLATE SEATING - * NOMINAL SURFACE NPT MAKE-IN 2-5/16 (58,7 mm) I I (3mm) . L SSPDEFLECTOR* 2- PENDENT REC - Frame 3- Sealing 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly S - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGIIT(TY4131) AND PENDENT (7-Y4231) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30. or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. " ...:.:._Page 40f8 -.-. SPRINKLER FINISH (See No 7) K TYPE TEMP. BULB UQIHD NATURAL BRASS J I CHROME PLATED JPOLYESTEI 1 WH[TE - 2.8 1/2' NPT PENDENT (TY1231) and UPRIGHT (TYI131) 135F/57°C Orange 1,2,3,5 l55'F8°C Red 175'F179°C Yellow 2OOFi3°C Green 286°F/141C Blue RECESSED PENDENT (1Y2231)' Figure 135cF/57C Orange 1,2,5 155°F/680 Red 175°Fi79°C Yellow 200°F/93°C Green RECESSED PENDENT çrY2231y' Figure 6 135'F/57°C Orange 155'F/68°C Red 175°F179°C Yellow 200°F/93'C Green 4.2 112' NPT PENDENT (fl'2231) and UPRIGHT (TY3131) 1 35°F/57°C Orange 1,2 155°F/68°C Red 175*F/79°C Yellow 200°F/93'C Green 286F/141°C Blue RECESSED PENDENT (rY2231)' Figure 7 1 35°F/57°C Orange. 1550F/68C Red 175FI79C Yellow 200'F/93C Green RECESSED PENDENT (7-Y2231)" I Figure 8 135'F/57'C Orange 155°F/68°C Red 175°F179°C Yellow 200°F193°C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354.01-E. 7. Where Polyester Coated Sprinklers are noted to be UL and C.UL Listed, the sprin- klers are UL and C.UL Listed as Corrosion Resistant Sprinklers. Installed with Style 10 (1/2' NPT) or Style 4.0 (3/4' NPT) 3/4' Total Adjustment Re- cessed Escutcheon, as applicable. Installed with Style 20 (1/2' NPT) or Style 30 (3/4' NPT) 1/2' Total Adjustment Re- cessed Escutcheon, as applicable. '"Frame and Deflector only. Listings and approvals apply to all colors (Special Order). f'JJA Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS TFPI 71 Installation The Series TY-FRB Sprinklers must be installed in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is loss of liquid from the bulb. Vv'ith the sprinkler held horizontally, a small air bubble should be present. The diamelerof the air bubble is approximately 1/16 inch (1,6 mm) for the 1350F/570C to 3/32 inch (2,4 mm) for the 286°F/14 icc temperature ratings. A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 It. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 314 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 fi.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. - Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler filling to suit. The Series .TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 13). With reference to Figures 1, 2, 3, and 4, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the TFPI7I Page 5 of 8 SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB UQUID NATURAL BRASS I CHROME J PLATED WHflE JPOLYESTER LEAD COATED 5.6 1/2 PENDENT (TY3231) and UPRIGHT (TY3131) 135°F/5rC Orange 1.2,3,4,5,6 1,2.3,5 155°Fi8C Red 175FI79C Yellow 200°Fi93C Green 286F/141°C Blue NPT RECESSED PENDENT Cy3231r Figure 9 135°FI5rC Orange 1,2,4,5 N/A 155°F/68*C Red 175F/79C Yellow 200°F193°C Green RECESSED PENDENT (1Y3231) Figure 10 1 35°F/5rC Orange 1,2.3,4,5 I 1,2,4,5 N/A 155F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 8.0 3/4. PENDENT (TY4231) and UPRIGHT (TY4131) 135F/57'C Orange 1,2,3,4,5,6 1,2,5 155W/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°FI141C Blue NPT RECESSED PENDENT (1Y4231) Figure 11 135F/57°C Green 1,2,4,5 N/A 155F/68°C Orange 175'FI79C Red 2OOF/93°C Yellow RECESSED PENDENT (rY4231)' Figure 12 135°0/57"C Orange - 1,2,3,4,5 NIA 155F/68°C Red 175°F179°C Yellow 20OF/93°C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCS) as Quick Response Sprinklers; however, the LPC does not rate the thermal sensitivity of recessed sprinklers. S. Approved by the City of New York under MEA 354-01E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. Installed with Style 10 (1/2' NPT) or Style 40 (3/4' NPT) 3/4' Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2 NPT) or Style 30 (3/4' NPT) 1/2' Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to all colors (Special Order). N/A: Not Available TABLES LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 14). With reference to Figure 1. 2, 3, and 4, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. , - . .- Page 6 of 8 TFPI7I 2-7/6'DIA. (73,0 mm) 1 3'4' (19.1 im,) 518*1/4' (15,9*6,4 mm) 2-1/4' 01k I 1/4' (6,4 friTO1 FACE OF '?- —1 1 MOUNTING SPRINKLER MOUNTING FnmN3 1/6'I MOUNTING / SURFACE 1 CLOSURE SERIES - TY-FRB 13/16'(20,6mm) FIGURE 5 SERIES 7Y-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8' OIA. 5'8114' (73,0 mm) 3/4' (19.1 mm) r (15,9*6,4 mm) 2-1/4' DR. 1/4' (6,4 mm) I SPRINKLER NO PLATE __ rf - I FACE OF ftm j MOUN1ING MOUNTING/ I 13 .2 MM) It J1 SURFACE .. . CLOSURE SERIES TY-FRB a/4'(19,1 mm) FIGURE 7 SERIES fl'-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT - 2-7/6' DIA. - (73,0 mm) 1i2*1/6' Ire (12,7rwn) 1(12,7*3,2mm) 2-1/4' DIA. 1/4' (6.4 MM) I / - 1 FACE OF (57,2 MM) ::-f MOUNTING SPRINKLER PLATE I 1/8' MOUNTING I / J 1 jT1 I (3.2—) I \ SURFACE CLOSURE SERIES 1t16 (33,3 TY-FRB 1-1/16' (27,0mm) FIGURE 6 SERIES 1Y-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8' 01k (730 mm) 1/2"(12,7 mm) r (1 2.7=3.2 mm) 2-1/4' DR. I 1/4'(6,4 mm) I FACE OF (57,2 mm) -'1 I MOUNTING SPRINICER PLATE I - FITTING 1/6' (32 mm) I / CLOSURE . MOUNTING 1 / SURFACE SERIES - 1-1/4' (3i.8 mm)j 7Y-FRB 1' (25,4 mm) FIGURE 8 SERIES TV-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and al/personnel who may be affected by. this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coaled sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- -Page* 7of8 C - _2-7/BDLA. (73,0 Mai) 1 314'(19'1 n'v$ V (15.9±6,4 mm) L.... 2-1/4' DA. I 1/4' (6.4 FACE OF -1 1 MOUN11NG SPRINKLER P1_ATE. FITflN3 I __ 1/8.V j k/ ___ 3.2 V. ___ ______ MOUN11NG/ I SURFACE SERIES 1-1/4' (31,8 mm) CLOSURE TY'FRB 3/4' (19,1 mm) FIGURE 9 SERIES fl'-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT - 2-7/8' DIA. .._j 5/8±1/4' (73,0 mm) 3/4 (19,1 mm) (15.9--6,4 mm) 2-1/4' DIA. 1/4' (6,4 mm) FACE f (57.2 mm) MOUNTING SPRINKLER PLATE Fri MOUNTING SURFACE CLOSURE SERIES 1-5/16' (33,3 mm) TYFRB 13/16'(20,6mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT __2-7/8' DIA. _ (73,0mm) t2±1/8' 1t2' (12,7Min) r (12,7±3,2 mm) 2-1/4' DIA. 1/4' (6,41 mm) SPRINKLEA PLATE I FACE OF f557,2 MOUNI1NG I I FIT1ING 1/8' MOUNTING SURFACE SERIES 1-1/4'(31,8 mm) CLOSURE TYFRB v (25,4 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8' DIA. (73,0 mm) J 1/2' (12,7 mm) r (12,7±3,2 mm) - 2-1/4' DIA. 1/4' (6,4 mm) FACE OF 7,2 mm) j MOUNTING SPRINKLER PLATE I FITTING MOUI.mNG SURFACE// CLOSURE SERIES 1516'i333I TY-FRB 1-1/16' (27,0 mm) FIGURE 12 SERIES TV-FRB RECESSED PENDENT WITH iWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0K-FACTOR, 314 INCH NPT tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable Standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. WRENCH RECESS (END A USED FOR 1/2' NPT MODELS) WRENCH RECESS (END 'B' USED FOR 3/4' NPT MODELS) FIGURE 13 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITh SPRINKLER WRENCHING AREA FIGURE 14 W-TYPE7 RECESSED SPRINKLER WRENCH Page 8 of 8 TFPI 71 P/N 57-XXX-X-XXX I I - MODEI./SlN - 330 2_8K UPRIGHT (1/2'NF'i) 1Y1131 331 2.8K PENDENT (l'NPT) 1Y1231 340 42K UPRIGHT (1/2'NPT) 1Y2131 341 4.2K PENDENT (12'NPT) TY2231 370 5.6K UPRIGHT (112'NPT) TY3131 371 5.6K PENDENT (112'NPT) TY3231 390 8.0K UPRIGHT (3/4'NPT) 1Y4131 391 8.0K PENDENT (3/4'NPT) ry'4231 I I I 155 175 200 286 RATING L 135 SPRINKLER 1 NATURAL BRASS 155°F/68°C 4 WHITE POLYESTER 175F/79C 9 CHROME PLATED 200'F/93C 7 1 LEAD COATED 286F/141C TABLE C PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products lobe defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS. OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO-THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED. INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- POSE. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Numbers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table C). Recessed Escutcheon: Specify: Style (specify) Recessed Es- cutcheon with (specify finish), P/N (specify). 1/2' (15 mm) We 10 Chrome Plated .........P/N 56-701-5-010 1/2' (15 mm) Style 10 Whhe Color Coaled ................P/N 56.701.4010 1/2' (15 mm) Style 10 Brass Plated ...........P/N S6-70120tO 1/2' (15 mm) Style 20 Chrome Plated .........P/N 56-705-9-010 1/2' (15 mm) Style 20 White Color Coaled ................ P/N 56-705-4010 1/2' (15 mm) Style 20 Brass Plated ...........P/N 56-705-2-010 3/4' (20 mm) Style 30 Chrome Plated .........P/N 56-705-9-011 3/4' (20 mm) Style 30 rMute Color Coated ................ PIN 56-70.4-011 3/4' (20 mm) Style 30 Brass Plated ...........P/N 56-705-2-011 3/4' (20 mm) Style 40 Chrome Plated .........P/N 56-700-9-010 3/4' (20 mm) Style 40 While Color Coated ................P/N 56-700-4-010 3/4' (20 mm) Style 40 Brass Plated ...........P/N 56-700-2-010 Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TYCO ARE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446