HomeMy WebLinkAbout6021 INNOVATION WAY; 110; FPC2019-0025; PermitPrint Date: 10/20/2021 Job Address: 6021 INNOVATION WAY, # 110, Permit Type: ' FIRE-Construction Commercial Parcel #: 2132611400 Valuation: $350,168.50 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: PERMIT REPORT (ity of Carlsbad Permit No: FPC2019-0025 CARLSBAD, CA 92009 Status: Closed - Finaled Work Class: Fixed Extinguishing Syste Track #: Applied: 02/08/2019 Lot #: Issued: 02/26/2019 Project #: Finaled Close Out: 08/14/2019 Plan #: Construction Type: Orig. Plan Check U: Inspector: Plan Check U: Final Inspection: Project Title: Description: EUREKA -INSTALL NEW ANSUL R-102 SYSTEM Applicant: S FPContractor: METRO FIRE AND SAFETY METRO FIRE AND SAFETY MIKE LAVALLE 2733 VIA ORANGE WAY, U 103 2733 VIA ORANGE WAY, U STE 103 SPRING VALLEY, CA 91978-1717 SPRING VALLEY, CA 91978-1717 (619) 670-3500 (619) 415-2248 FEE AMOUNT FIRE Hood & Duct Extinguishing System Initial Sys $417.00 Total Fees: $417.00 Total Payments To Date: $417.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Ini-ANSUL.1 It is hereby certified that Larry Rosner of /Certificate of / / Training / Metro Fire & Safety, Inc. Spring Valley .hassuccessfully completed the web-based training course R-102 Restaurant, Fire Suppression System- Design, Installation, Recharge•& Maintenance Training Hrs: 8 Training Date: April 30,2017 Expiry Date: AriI 3092020 - K athe rinze A. Achan GobEIl Drectar —TechncaOServices Tyco FeProtecton Pioduicts. johnso n-, oritjrib. SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-1 3-1-07 REV. 7 SYSTEM DESIGN The ANSUL R-102 Restaurant Fire Suppression System may be used on a number of different types of restaurant cooking appli- ances and hood and duct configurations. The design information listed in this section deals with the limitations and parameters of this pre-engineered system. Those individuals responsible for the design of the R-102 system must be trained and hold a current ANSUL certificate in an R-102 training program. The R-102 and the PIRANHA systems use compatible agents and components, therefore, they may be used together for cooking appliance, hood; and duct protection. The primary ANSUL AUTOMAN Release can be either an R-102 or a PIRANHA ANSUL AUTOMAN Release and can actuate up to two additional R-102 or PIRANHA Regulated Actuators. In systems utilizing a 101 remote release, any combination of the maximum number of regulated actuators can be used. Both systems must actuate simultaneously. Each system must be designed and installed per its appropri- ate manual. Adjacent appliances requiring protection must be protected with the same type of system, either R-102 or PIRANHA, unless the center-to-center spacing between the adjacent R-102 and PIRANHA nozzles is no less than 36 inches. When appliances are protected with R-102 nozzles, the hood and connecting duct above those appliances cannot be pro- tected with PIRANHA nozzles. Mixing systems in a common plenum is not allowed. One of the key elements for restaurant fire protection is a correct system design. This section is divided into ten sub-sections: Noz- zle Placement Requirements, Tank Quantity Requirements, Actu- ation and Expellant Gas Line Requirements, Distribution Piping Requirements, Detection System Requirements, Manual Pull Sta- tion Requirements, Mechanical Gas Valve Requirements, Electri- cal Gas Valve Requirements, Electrical Switch Requirements, and Pressure Switch Requirements. Each of these sections must be completed before attempting any installation. System design sketches should be made of all aspects of design for reference during installation. NOZZLE PLACEMENT REQUIREMENTS This section gives guidelines for nozzle type, positioning, and quantity for duct, plenum, and individual appliance protection. This section must be completed before determining tank quantity and piping requirements. Duct Protection - SingleN6i1 All duct protection is UL listed without limitation of maximum duct length (unlimited length). This includes all varieties of ductworks both horizontal and vertical including ducts that run at angles to the horizontal and ducts with directional bends. The R-102 system uses different duct nozzles depending on the size of duct being protected. GENERAL INFORMATION 1. Nozzles must be located 2-8 in. (5-20 cm) into the center of the duct opening, discharging up. See Figure 1. 2-8 IN. (5-20 cm) FIGURE 1 000173 In installations where a UL listed damper assembly is employed, the duct nozzle can be installed beyond the 8 in. (20 cm) maximum, to a point just beyond the damper assem- bly that will not interfere with the damper. Exceeding the max- imum of 8 in. (20 cm) in this way will not void the UL listing of the system. Previously listed 3 flow number and 5 flow number duct pro- tection detailed in earlier published manual, Part No. 418087- 06, can also still by utilized. DUCT SIZES UP TO 50 IN. (127 cm) PERIMETER! 16 IN. (41 cm) DIAMETER One 1W nozzle (Part No. 419336) = one flow number 50 in. (127 cm) perimeter maximum 16 in. (41 cm) diameter maximum bcJcrJZESUP_TOJO0 IN. (54 cm) RIME PT/ 32 IN. (8fn) DIAMETER 'One 2W Nozzle (Part No. 419337) = two flow numbers iLl 0nJ254 cm) perimeter maximum 32 in. (81.3 cm) diameter maximum The chart below shows the maximum protection available from each duct nozzle. Part 3.0 Gallon 1.5 Gallon Description No. System System 2W Nozzle 419337 Maximum Maximum 100 in. (254 cm) 100 in. (254 cm) Perimeter Perimeter 1W Nozzle 419336 Maximum Maximum 50 in. (127 cm) 50 in. (127 cm) Perimeter Perimeter SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-5 4-1-06 REV. 4 CPlenunv The R-102 system uses the 1W Nozzle (Part No. 419336) or the 1 Nozzle (Part No. 419335) for plenum protection. The 1W noz- zle tip is stamped with 1W and the 1 nozzle tip is stamped with 1 N, indicating they are one-flow nozzles and must be counted as one flow number each. When protecting a plenum chamber, the entire chamber must be protected regardless of filter length. VERTICAL PROTECTION - GENERAL o One 1W nozzle will protect 4 linear feet (1.2 m) of plenum. The maximum distance from the end of the hood to the first and last nozzle must be no more than 2 ft. (.6 m). After the first nozzle, any additional nozzles must be positioned at a maximum, of 4 ft. (1.2 m) apart down the entire length of the plenum. The plenum P. width must not exceed 4 ft. (1.2 m). (The 1W nozzle can be used on single or V-bank filter arrangements.) See Figure 6. FIGURE 6 000197 'When protecting plenums with the 1W nozzle, two options of cov- erage are available: P. Option 1: The 1W nozzle must be on the center line of the single or "V' bank filter and positioned within 1-20 in. (2.5-51 cm) above the top edge of the filter. See Figure 7. 20 IN. (51 cm) MAXIMUM Option 2: The 1W nozzle must be placed perpendicular, 8-12 in. (20-30 cm) from the face of the filter and angled to the center of the filter. The nozzle tip must be within 2 in. (5 cm) from the perpendicular center line of the filter. See Figure 8. DM) 20 cm) IUM NOZZLE TIP MUST BE W THIS AREA FIGURE 8 000200 HORIZOMAC 'IN-NOZZLE—PART NO. 419335 - SlNGLEBANKPROTEC- m) of single filter bank rp _1e um.-The-nozzle(s)-must-be-mounted in the plenum, 2 to 4 in. (5 to 10 cm) from the face of the filter, centered between the filter height dimension, and aimed down the length. The nozzle must be positioned 0-6 in. (0-15 cm) from the end of the hood to the tip of the nozzle. See Figure 9. 2-4 IN. 10 Fr. (3.1 m) MAXIMUM 000201 000202 FIGURE 9 1 IN. (2.5 cm) MINIMUM 20 IN. (51 cm) MAXIMUM 1 IN. (2.5 cm) MINIMUM FIGURE 7 000199 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-7 10-1-02 REV. 3 Appliance Protection The following pages detail types of appliance protection. Each design requires several factors: correct nozzle choice, correct noz- zle height above hazard, correct nozzle location and correct aim- ing point. Fryer-SingleNozzIeProtection, 1. Design requirements for fryers are broken down into two types. A. FRYERS WITHOUT DRIPBOARDS If the fryer does not include a dripboard, measure the internal depth (horizontal dimension from front to back) and length of the frypot. If the fryer includes any dripboard areas, measure both the internal depth (horizontal dimension from front to back) and length of the frypot portion, and then measure the internal depth and length of the overall hazard area including any dripboard areas. 2. Using Table, 'Maximum Cooking Area Dimension - Single Nozzle Fryer Protection," determine which nozzle is needed to protect the fryer based on the maximum dimensions listed. If the fryer does not include a dripboard, use the maxi- mum dimensions listed in the first column of the table to select the correct nozzle. If the fryer includes any dripboard areas, use both the maximum frypot dimensions in the first column of the table, and the maximum overall dimensions in the second column of the table to select the correct nozzle. None of the maximum dimensions in either column may be exceeded. 3. If either the maximum frypot or the overall sizes are exceed- ed, an additional nozzle(s) will be required. Refer to the mul- tiple nozzle requirements. Examp/e:A fiyer with a dr49board The frisk/a c/the hypet without the drØboard measures 18/n. in depth x 18 in. in length (46 cm 46 cm) and the friside of the overall area fricludfrig the dnpboard measures 18 in. in depth x24 in. in /engm (46 cm 61 cm). From the Table 'Maxfrnum Cooking Area Dfrnensibn - Single Nozzle Fryer Protect/on, "eit/ierthe 3Northe 2.90 nozzle should be select- ed to protect the fryer, dependfrig on the maximum nozzle heiqht above the hiyerandthepos/t/onfrig requkements allowed Refer to appropnete Figures. TOP OF FRYER SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-9 4-1-06 REV. 8 Fryer Single Nozzle Protection (Continued) Maximum Area Dimensions - Single Nozzle Fryer Protection (Continued) Max. Size Max. Size Overall Type of Nozzle Height Nozzle Frypot Only With Dripboard Nozzle Above Top of Fryer Location 19.5 in. x 19 in. 19.5 in. x 253/8 in. 290 13 in. to 16 in. See Figure 17 (50 cm x 48 cm) (50 cm x 65 cm) (33 to 41 cm) 19.5 in. x19 in. 19.5 in. x 25 3/8 in. 3N See Figure See Figure 18 (50cmx48cm) (50cmx65cm) 18 8(1181. l8 in- x273/4in. (rJ See Figure 19 (46cmx46 cm) (46mx70:5cm) (64cmto89cm) FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD 290 NOZZLE TIP POSITIONED OVER THE MIDPOINT OF THE HAZARD AREA ± 3 IN. (7.6 cm) FROM THE MIDPOINT ALONG THE LONGEST SIDE OF THE HAZARD AND ± 1 IN. (2.5 cm) FROM THE MIDPOINT ALONG THE SHORTEST SIDE OF THE HAZARD AND AIMED AT THE MIDPOINT OF THE COOKING AREA. FIGURE 17 002286 34 IN. (86 cm) MAXIMUM DIAGONAL DISTANCE BETWEEN NOZZLE AND CENTER OF HAZARD AREA 21 in. (53 cm) I -- - MINIMUM '<Z VERIlCAL_________ NOZZLE HEIGHT -I FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD 3N NOZZLE TIP POSITIONED ANYWHERE ALONG OR WITHIN PERIMETER OF COOK- ING SURFACE AND AIMED TO THE CENTER OF THE COOKING AREA. FIGURE 18 002287 00001; 3Nr—><—_ 000000 FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD NOTE: 3N NOZZLE TIP MUST BE LOCATED WITHIN THE PERIMETER OF THE SURFACE AREA WITHIN THE FRONT HALF OF THE FRY POT AND AIMED AT THE CENTER. FIGURE 19 12 IN. (30.5 cm) MAXIMUM 14 IN. (35.6 cm) MAXIMUM FRONT TO REAR CENTERLINE SHELF CAN OVERHANG BURNER(S) BY MAXIMUM OF 11 IN. (28 cm) SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-13 3-1-07 REV. 7 tectionwjJ The R-102 system uses five different nozzles for the protection of ranges. Two of the design options require a one-flow nozzle and three of the design options require two-flow nozzles. NOTICE A 13 in. (33 cm) diameter wok pan is the largest wok size that can be protected on ranges. When protecting hot top ranges, the entire cooking surface must be protected. Range Protection (1-Flow Nozzle) Single and multiple burner ranges can be protected using a 1 N nozzle, Part No. 419335. The nozzle tip is stamped with IN, indi- cating that this is a one-flow nozzle and must be counted as one flow number. When using this nozzle for range protection, the maximum length of the burner grates being protected with a single nozzle must not exceed 32 in. (81 cm) and the maximum area of the burner grates must not exceed 384 sq. in. (2477 sq. cm) per nozzle. When protecting a range, the 1 N nozzle must be located a maxi- mum of 10 in. (25.4 cm) from each burner grate centerline and must be aimed at the center of the cooking surface. See Figure 26. ''1 401N. (102 cm) f 10 IN. (25 cm) MAXIMUM When this type of hazard is equipped with a back shelf located above the range top, two protection options are available: One requires a iF nozzle, Part No. 419333, and the other option requires a 260 nozzle, Part No. 419341. Option r IF Nozzle: When using the i Fnozzlé for range protec- tion with or without back shelf, the maximum length of the burner grates being protected must not exceed 28 in. (71 cm) and the maximum area of the burner grates must not exceed 336 sq. in. (2168 sq. cm). See Figure 27 for nozzle location details. 1 NOZZLE 1 NOZZLE LOCATED OVER FRONT EDGE OF BURNER GRATE AND ORIENTED SO NOZZLE TIP FLATS ARE PARALLEL WITH BURNER GRATE FRONT TO REAR CENTERLINE AND SHALL BE AIMED AT THE CENTER OF THE COOKING SURFACE. FIGURE 27 000238 Option 2: 260 Nozzle: When using the 260 nozzle for range pro- tection with or without back shelf, the maximum length of burner grates being protected must not exceed 32 in. (81 cm) and the maximum area of the burner grates must not exceed 384 sq. in. (2477 sq. cm). Nozzle must be located on the front edge of the burn- er grates and aimed at a point 10 in. (25 cm) from the back edge of the burner grates. Nozzle must be mount- ed 30 to 40 in. (76 to 102 cm) above the hazard sur- face. See Figure 28. 260 NOZZLE SHELF CAN OVERHANG BURNER(S) BY MAXIMUM OF 11 IN. (28 cm) IN NOZZLE 32 IN. (81 cm) MAXIMUM AIMING POINT 30-4OIN. I (76-102cm) I 18 IN. (45.7 cm) MINIMUM 10 IN. (25 cm) FROM BACK OF BURNER GRATES FIGURE 28 0002300 FIGURE 26 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-21 10-1-02 REV. 3 (:2-Flo NTGriddle-Protectio—n Option 2 -'NIëPiiñiitLocated (Continued) L . . Low,ProxiniityAppIication:10 in.--to 20 in. (25 cm to 51 cm) - - .---------- (kove-the cooking surface. T~ejow,proximity-appfiCation uses the 2120 nozzle,i 41,9343. The nozzle tip is stamped with 2120 indicating this is a two-flow nozzle and must be counted as two flow numbers.____________ - One 2120 nozzle will protect amaximumcookingareaof.i 440 S~q. in. (9290 sq. cm) with a 48. in.5 When using this nozzle for griddle protection, the nozzle must be positioned along the perimeter to 2 in. (5.1 cm) inside perime- ter, and aimed at the center of the cooking surface. See Figure 43 and 44. NOZZLE LOCATION f I 0-2 IN. (0-5cm) I INSIDE PERIMETER 20 IN. ._..I L- OF COOKING SURFACE (51cm) II 'II MAXIMUM I HEIGHT II 0F2120 I II NOZZLE TIP r I / I 10 IN. (25 cm) II / I MINIMUM HEIGHT I II 0F2120 I II / NOZZLEP 000243 EDGE OF COOKING SURFACE FIGURE 43 000243 COOKING AREA I I ----CENTER OF COOKING SURFACE I U / A COOKING REA I— AIM POINT ILI I ___------ 2120 NOZZLE LOCATED ALONG COOKING SURFACE EDGE ANY SIDE OF GRIDDLE SURFACE WITHIN 0-2 IN. (0— 5cm) OF COOKING SURFACE EDGE. NOZZLE MUST BE AIMED AT CENTER OF COOKING SURFACE. FIGURE 44 000241 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-24 NEV. 6 4-1-06 Char-Broiler Protection The R-1 02 system uses the IN nozzle, (Part No. 419335) for gas- radiant/electric char-broiler `protection:--~ The nozzle tip on the 1 N nozzle is stamped with a 1 N, indicating that this is a one-flow nozzle and must be counted as one flow number. One IN nozzle will protect a hazard with a maximum length of 36 in. (91 cm) and a total cooking area which does not exceed 864 sq. in. (5574 sq. cm). The nozzle tip must be located 15 to 40 in. (38 to 102 cm) above the hazard surface. When using this nozzle for gas-radiant/electric char-broiler protection, the nozzle must be positioned anywhere along or within the perimeter of the maximum cooking area and shall be aimed at the center of the cooking surface. See Figure 51. 40 IN. (102 cm) MAXIMUM 15 IN. (11 m) ;MINIMUM 000257 FIGURE 51 Mike Lavalle Abby Maguire <abby.maguire@jci.com> Sent: Friday, December08, 2017 11:36 AM To: Mike Lavalle Subject: Cheesemelters Please see the below in regards to cheesemelters. This solution addresses the protection of salamander broilers and cheesemelters. Salamander broilers or those identified as "cheesemelters" that have the capability of broiling meat, must be protected using the upright broiler protection parameters. Generally, true cheesemelters do not have drip pans and cannot be used to broil meat. They are normally used to warm sandwiches or keep dishes of food warm. If they do not have broiling capabilities or a drip pan. they may not require protection unless the authority having jurisdiction requires it. If the appliance is considered a salamander broiler or protection is required by the authority having Jurisdiction, protection can use traditional upright broiler protection ('either the 1/2N nozzles, or the IN nozzle) . . - as approved by the AHJ or they/ can be protected with Salamander lzstedprotectzo .iigmig!iW..iwzzicj The R-1 02 design, installation and maintenance manual outlines two options for protecting a salamander broiler using the IN nozzle. The nozzle can be installed fixed to the broiler and aimed into the cooking chamber 'the nozzle can be located above and out front of the broiler and cooking chamber. There is also another option using the IF nozzle aimed with horizontal discharge into the cooking chamber ,from above and out front of the broiler. Refer to the manual for various options and installation requirements. Abby Maguire Applications Specialist Johnson Controls +1 800 862 6785 THIS MESSAGE MAY CONTAIN INFORMATION THAT IS PRIVILEGED AND CONFIDENTIAL. The information contained in, or attached to. this message is intended solely for the use of the specific person(s) named above. If you are not the intended recipient then you have received this communication in error and are prohibited from review, retransmission, taking any action in reliance upon, sharing the content of, disseminating or copying this message and any of the attachments in any way. If you have received this communication in error, please contact the sender immediately and promptly delete this message from all types of media and devices. Thank you. FIGURE 4-35 LONGITUDINAL CENTERLINE i -.c.COOKING AREA 000239 290 NOZZLE TIP - LOCATION CENTER OF COOKING SURFACE ±2 IN. (50 mm) 000240 COOKING AREA COOKING AREA 290 NOZZLE TIP LOCATION 0-1.5 IN. (38 mm) IN FROM EDGE OF COOKING SURFACE AREA SEC7I0N 4— SYSTEM DESIGN UL EX3470 ULC EX3470 PAGE 4-16 REV. 11 2014-SEP-01 Nozzle -LOW 71 -Flow) Application The low proximity 1flow.noizleapplication for the protection of ranges N nozzle—' The nozzle is stamped with iN indicating that it is a one-flow nozzle and must be counted as one flow number, When using the 1 nozzle for low proximity range protection with or without obstruction, the maximum length of the burner grates being protected must not be exceed 24 in. (609 mm) length, aimed along a centerline to a point 20 in. (508 mm) from the end of the length, protecting a maximum width of 18 in. (457 mm). When protecting a range, the iN nozzle must be located a maximum of 9 in. (228 mm) from each burner grate centerline and must be positioned above the edge of the hazard area to be protected. The 1N nozzle tip must be positioned at or below the obstruc- tion, if present. The protected area begins at the point straight down from the nozzle tip. The nozzle can be placed at the side of the range aimed either left or right, or can be placed in the front or back of the range. See Figures 4-33 and 4-34 for nozzle location details. R-102 Restaurant Fire Suppression Manual Range Protection Two 290 (2-Flow) Nozzles - Low Proximity Application 15 in. to 20 in. (381 mm to 508 mm) above the cooking surface. The low proximity 2-flow application requires the use of two 290 nozzles. Both nozzles are stamped with 290 indicating they are two flow nozzles and must be counted together for a total of four flow numbers: Two 290 nozzles will protect a cooking area of 1008 in.2 (65032 mm2) with a maximum dimension of 36 in. (914 mm). When using two of these nozzles for low proximity range protec- tion, the nozzles must be positioned along the cooking surface perimeter to 1.5 in. (38 mm) inside the perimeter, and aimed at a 450 angle along the longitudinal centerline of the range. See Figures 4-35 and 4-36. 290 NOZZLE TIP - 4- LOCATION O-1.SIN. (0-38 mm) IN FROM EDGE OF 45 COOKING SURFACE 45* I- 15 IN. TO2OIN. I IS IN. TO2OIN. (381 to 508 mm) (381 to 508 mm) MAXIMUM I MAXIMUM I II 000000 T_ 15-20 IN. I AIM (381-508 mm) I POINT 20 IN" [_(oa) 0000 FIGURE 4-33 I AIM POINT I I 201N. fl(508 mm) 24 IN. (609 mm) FIGURE 4-34 9 IN. (228 mm) 18 IN. (457 mm) 00005 I 290 NOZZLE TIP LOCATION CENTER OF COOKING SURFACE 290 NOZZLE TIP LOCATION ± 2 IN. (50 mm) 0-1.5 IN. (38 mm) IN FROM EDGE OF COOKING SURFACE FIGURE 4-36 El 3.0 3.0 3.0 GALLON GALLON GALLON TANK TANK TANK NO.3 NO.2 NO.1 If / I \ TWO TANK ENCLOSURE 3 GALLON REGULATED DOUBLE TANK NITROGEN ASSEMBLY PART NO. RELEASE ASSEMBLY, CARTRIDGE OR 430324 (INCLUDES (2) OR 3 GALLON LT-A-101-30 CARTRIDGE HOSES AND (2) REGULATED (REGULATED ACTUATOR GROMMETS) ACTUATOR ASSEMBLY ONLY) NOTE: IF TWO TANK ENCLOSURE ASSEMBLY, PART NO. 430324, IS CONNECTED TO THE 3 GALLON REGULATED RELEASE ASSEMBLY, NO ADDITIONAL REGULATED ACTUATOR(S) ASSEMBLIES CAN BE USED. FIGURE 97 50e007 Plenum Branch Line 3/8 in. 4 ft. (1.2m) 2 ft. (.6 m) Appliance Branch Line 3/8 in. 12 ft. (3.7m) 2ff. (.6m) SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-52 REV. 3 4-1-06 DISTRIBUTION PIPING REQUIREMENTS (Continued) pistributionPipingRequirements-9:OGaIIoj:::J This optional configuration consists only of three 3-gallon tanks, all pressurized from a single double-tank nitrogen cartridge with > expellant gas hoses connected as shown in Figure 97. Tanks No. 1 and No. 2 must be connected directly to the regulator with sep- arate expellant gas hoses and Tank No. 3 must be connected to Tank No. 2 with a third expellant gas hose as shown in Figure 97. Each tank must be connected to an independent distribution pip- ing network as shown in Figure 97. Distribution piping require- ments for each network must be as follows: The maximum length between the start of the first branch line and the start of the last branch line must not exceed 24 ft. (7.3 m). When the supply line is split, the combined total of both legs of the supply line (from the start of the first branch line to the start of the last branch line) must not exceed 24 ft. (7.3 m). See Figure 93. The total length of all branch lines must not exceed 36 ft. 0. (10.9 m). See Figure 93. Use a 3/8 in. union to connect the tank adaptor to the 3/8 in. supply line. A maximum of two nozzles are allowed per duct branch line. When using this 9.0 gallon system configuration, no mani- folding of distribution piping is allowed. When an ANSULAUTOMAN Regulated Release is utilized in this configuration, additional regulator actuators cannot be used. Only 3 gallon tanks can be utilized in this configuration. The requirements of the following table must not be exceeded for each 3 gallon tank: Duct Requirements Supply Line Branch Line =4 inn Maximum Rise 6 ft. 4 ft. (1.8 m) (1.2 m) Maximum 90° 9 4 Elbows Maximum Tees 1 2 cMaxirTPum1Fl0-w 11* Numbers 4 4 'Exceptions: Twelve (12) Bow numbers are allowed in any one tank for duct and plenum protection ONLY. Twelve (12) flow numbers are allowed with any one tank using only two-how appliance nozzles. Twelve (12) flow numbers are allowed with any one tank using only three-flow appliance nozzles. Special Instructions: When tour (4) Dean Industries GTI Gas Fryers are protected at low proximity as shown in Figure 58 on Page 4-32, the discharge piping must be as shown in Figure 59 on Page 4-32. For certain McDonald's applications, 11.5 flow numbers are allowed when using a combination of one (1) 2W duct nozzle, one (1) 1/2N electrostatic precipitator nozzle, one (1)1 N plenum nozzle, and four (4) two-flow appliance nozzles. Contact Ansul Applications Engineering Department for additional information. SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-54 REV. 4 3-1-07 Detector ReplacementRequurements (Continued) j [ CO APPLIANCES If the cooking appliance is located under an exhaust duct where a detector has been mounted, it is normally not necessary to utilize another detector for that cooking appliance, provided the detector is not more than 12 in. (30 cm) into the duct. See Figure 100. APPLIANCE APPLIANCE APPLIANCE APPLIANCE REQUIRES COVERED BY COVERED BY REQUIRES SEPARATE DETECTOR DETECTOR SEPARATE DETECTOR UNDER DUCT UNDER DUCT DETECTOR Fusible Link Selection FIGURE 101 000270 FIGURE 100 000269 Each cooking appliance with a continuous cooking surface not exceeding 48 in. x 48 in. (122 x 122 cm) can be protected by a minimum of one detector. Cooking appliances with a continuous cooking surface exceeding 48 in. x 48 in. must be protected by at least one detector per 48 in. x 48 in. cooking area. Detectors used for Cooking appliances must be located above the protected appliance toward the exhaust duct side of the appliance. The detector should be located in the air stream of the appliance to enhance system response time. Note: For overlapping detector coverage, see Page 4-42 for design requirements. Detection Line Requirements CONDUIT Rigid conduit or 1/2 inch EMT thin-wall conduit may be used. Standard steel conduit fittings (compression type are recommend- ed) must be employed to properly install the detection system. All conduit or pipe must be firmly supported. When using pipe, make certain that all ends are carefully reamed, deburred and blown clear of chips and scale before assembly. NOTICE The conduit offset can be used at the top or bot- tom of the regulated release to Change direction of the conduit. The conduit offset Cannot be used with pulley tees. All other changes in direc- tion must be made by using ANSUL approved pulley elbows, Part No. 423254 or 415670. See Figure 101. When possible, temperature readings should be taken at each detector location to determine correct fusible link temperature rat- ing. Temperature can be recorded using either a maximum regis- tering thermometer, Part No. 15240, temperature tape or any other accurate thermometer. t4:~) A115"* TEMPERATURE RATING STAMPED ON FUSIBLE L : ® LINK BODY 000170 K STYLE ML STYLE 500 °F (260 C) ONLY FIGURE 102 Select correct UL Listed fusible link(s) for installation in detector(s) according to the temperature condition. Two styles are available. See Figure 102. See Component Section for detailed temperature ratings. Fire Suppression System Distributor Certificate of Installation 110 ne Completed by Regional Office Job Name EUREKA! Job Number 3517181-92 Job Address 6021 INNOVATION WAY Type of System: Ansul CARLSBAD, CA. 92008 Pyrochem 0 Other To be Completed by Fire System Distributor Company Name METRO FIRE AND SAFETY Address 2733 VIA ORANGE WAY #103 SPRING VALLEY, CA. 91978 System Model R1029 GAL. ?-°/'7 057? 47 Serial Number /(7 Fuel/Energy Shut Off Device Gas Valve: Mechanical 0 Electrical LI Size2" Installed. Tested on Electric Equipment Shut-down Tested: Yes EJN0 Date This Fire Suppression System is installed in accordance with the Manufacturer's instructions and drawings, NFPA 96 and 17 (current issues) and all applicable state and local codes. All electrical work or work performed by others to complete the installation of this system has been completed. Exceptions to the above are noted below. (Use back of sheet if necessary) Installer's Name 145A16-9- Signatu Date To be Completed by Owner or Owners Representative I have received a copy of the Fire Suppression System Owner's Manual and I understand it. I also understand that it is the recommendation of the National Fire Protection Association (NFPA) that the system be insjzetedyery six months to maintain its reliability. Si Date Vsq To be Completed by the Authority Having Jurisdiction Functional tests have been witnessed and the system performs as designed. Print Name U.Y3C' Jurisdiction QAjT Phone Numb Signatu Date J -8J Fire Suppression System Distributor Certificate of Insurance. v2 5-1 -07