HomeMy WebLinkAbout2794 WOODWIND RD; ; CB940263; Permit[7O21
B U I L D I N G P E R M I T Permit No: CB940263
06/17/94 15:49 Project No: A9400381
Page 1 of 1 Development No:
Job Address: 2794 WOODWIND RD Suite:
Permit Type: RESIDENTAL ADD/ALT 762 6/7/5'4 1 0t 02
Parcel No: 156-331-05-00 - Lot#:
Valuation: 30,000
Construction Type: VN
Occupancy Group: R3/M1 Reference#: Status: ISSUED
Description: ADD BEDROOM/FAMILY ROOM CODE Applied: 03/14/94
ENFORCEMENT VIOLATION Apr/Issue: 06/15/94
Entered By: MDP
Appl/Ownr : BLUE COAST CONSTRUCTION 619 4565535
7825 FAY AVE
LA JOLLA, CA. 92037
*** Fetes Required *** ,/FA e/5olleced & Credits
Fees: 541.00
Adjustments: / rOO Totarre'dits: \ .00
Total Fees: S49-0 \ 185.00
Balance\Due: \ 364.00
ni Fee nit -----Data
Building Permit 285.00
Plan Check 185.00
Strong Motion Fee 3.00
BUILDING TOTAL 473.00
Each Plumbing Fixture Tra , 7.00 21.00
Each Building Sewer > 1 15.00 15.00
PLUMBING TOTAL I NCORPORATED / 56.00 19,52 10
Enter "Y" for Electric Isue,> çc\\J / 10.00 Y
Enter "Y "for Remodel > \) 10.00 Y
* ELECTRICAL TOTAL // /" 20.00
FINA
PPROVJ
INS P DATE ''
4
CLEAR 110E
CITY OF CARLSBAD
2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161
B U I L D I N G P E R M I T Permit No: C8940263
10/13/95 11:13 Project No: A9400381
Page 1 of 1 Development No:
Job Address: 2794 WOODWIND RD Suite:
Permit Type: RESIDENTAL ADD/ALT 4134 10/13/95 0001 01 02
Parcel No: 156-331-05-00 Lot#: C-PRMT 143.00
Valuation: 30,000 Construction Type: VN
Occupancy Group: R3/M1 Reference#: Status: ISSUED
Description: ADD BEDROOM/FAMILY ROOM CODE Applied: 03/14/94
ENFORCEMENT VIOLATION Apr/Issue: 06/15/94
Entered By: MDP
Appl/Ownr : BLUE COAST CONSTRUCTION 619 456-5535
7825 FAY AVE
LA JOLLA, CA. 92037
*** Fees Required Fees 0o11ected & Credits
?) If
Fees: 69c.0IO
~%Y~ Adjustments: / Totarits: .00
Total Fees. /692.00 Total Payment. 549.00 I 4\ NK~B \alance Due:\ 143.00
------------------ .L ---Un ---- tion ! xt e
-
Data
Building Permit / N \ /" 285.00
Plan Check I . 1 185.00
Striong Motion Fee 3.0
Additional Renewal Fees 14(36/) °143.00
* BUILDING TOTAL c4J(4 cf-JJ/ 616.00
Enter "Y" for Pluming Isse Fee '..> 20.00 Y
Each Plumbing Fixture or Trap -0 3/ 7.0,0 21.00
Each Building Sewer \ > ' 1" 15.00 15.00 irJCcRPORTED * PLUMBING TOTAL 1952 / 56.00
Enter "Y" for / 10.00 Y
Enter "Y" for Remodel \ 'ThJ// > \\ / 10.00 1
* ELECTRICAL TOTAL N,S g 1 0 20.00
FINAL APPRO\
INSP. ______'DATE
CLEARANCE
CITY OF CARLSBAD
2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161
PERMiT APPUCATION
City of Carlsbad Building Department
2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161
S
1. PERMIT TYPE
A - U Commercial U New Building U Tenant Improvement
B - 0 Industrial 0 New Building 0 Tenant Improvement
C - 91 Residential 0 Apartment 0 Condo 0 Single Family Dwelling 0 Addition/Alteration
0 Duplex 0 Demolition 0 Relocation 0 Mobile Home 0 Electrical @Plumbing
PLAN CHECK NO. q Lfr 23
6 15 O3/1•/94 0001 01 02
C-PMT i5.00
0 Mechanical 0 Pool 0 Spa 0 Retaining Wall 0 Solar 0 Other
2. PROJECT INFORMATION I FOR OFFICE USE ONLY
Address 2&00&.-,.i 2d Building or Suite No.
Nearest Cross Street e4i 720 C, IF
LEGAL DESCRIPTION Lot No. Subdivision Name/Number Unit No. Phase No.
' t '0 2 art', '11 ,i'a #' /o r3 7 /0D S' CHECK BELOW IF SUBMIITED: (_7
02 Energy Calcs 02 Structural Calcs 02 Soils Report 0 1 Addressed Envelope
DESCRIPTION OF WORK
SQ. FT. # OF STORIES Al i. U.)NIAUI PERUN (it different from applicant)
NAME ADDRESS
CITY STATE ZIP CODE DAY TELEPHONE
APPLICANT CONTRACTOR U AGENT FOR CONI'RACFOR U OWNER Li AGENT FOR OWNER
NAME /4,v,é E 4'~ ADDRESS 377 54P45.4
CITY STATE eV ZIP CODE P7I'O?DAY TELEPHONE ('6/
PROPERTY OWNER
NAME KC4ti,tJ i#'S.4 4,k/4 ,4//ADDRESS C) 75' Uit c' a' 1,'c/ ,'f(/
CITY CIVIs,64cl STATE &I ZIP CODE f2-4''F DAY TELEPHONE (61") 720-70 7,P
WNIHACIUI(
NAME 4'/ 45i // ShDDRESS 7f25 /#4/ 4//
CIT/J,//4 STATE eV ZIP CODE 72017 DAY TELEPHONE
STATE UC. # LICENSE CLASS CITY BUSINESS UC. #
DESIGNER NAME4 ADDRESS
CITY STATE (44 ZIP CODE DAY TELEPHONFL/P)1/,7ç99,tTATE UC. #
Workers Uompensation Declaration: I flereoy ariirm [flat I nave a certiticate 01 consent to sell-insure issued by the Director 01 Industrial
Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified
by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C).
INSURANCE COMPANY 71/' /iv'c,' POLICY io- fEXPIRA'nON DATE
eriiucate 01 t.xempuon: i ceruiy mat in tne periormance or tne WOK [or hich this permit is issued, I shall not eni manner
so as to become subject to the Workers' Compensation Laws of California.
SIGNATURE DATE
8. OWN ER-BUIU)ER DECIARA11ON
Owner-Builder Declaration: I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
1, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or
offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds
or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended
or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden
of proving that he did not build or improve for the purpose of sale.).
I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions
Code: The Contractor's License Law does not apply loan owner of property who builds or improves thereon, and contracts for such projects
with contractor(s) licensed pursuant to the Contractor's License Law).
0 I am exempt under Section Business and Professions Code for this reason:
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the
provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code)
or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars [$5001).
SIGNATURE DATE
COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY:
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and
prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act?
DYES ONO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district?
DYES ONO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site?
DYES ONO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1, 1989 UNLESS THE APPLICANT
HAS MET OR IS MEETING THE REQUIREMENTS OF ThE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DIS11IICF.
WNSTRUCI1ON LENDLNG AGENCY
1 hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(1) Civil Code).
LENDER'S NAME LENDER'S ADDRESS
APPLICANT CERTIFICATION
I certify that I have read the application and state that the above information is correct. I agree to comply with all City ordinances and State laws
relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection
purposes. I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARISBAI) AGAINST ALL UABIU11ES JUDGMENTS (X)STS
AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF lIIIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5,0" deep and demolition or construction of structures over 3 stories in height.
Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the
building or work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by
such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 303(d) Uniform,Buildin Code).
PLICANTS SIGN A URE DATE:
~ . . , &2,, L /1
CITY OF CARLSBAD
INSPECTION REQUEST
PERMIT# CB940263 FOR 02/25/97
DESCRIPTION: ADD BEDROOM/FAMILY ROOM CODE
ENFORCEMENT VIOLATION
JOB ADDRESS: 2794 WOODWIND RD
APPLICANT: BLUE COAST CONSTRUCTION PHONE:
CONTRACTOR: PHONE:
OWNER: PHONE:
INSPECTOR AREA PY
PLANCK# CB940263
0CC GRP R3/Ml
CONSTR. TYPE VN
STE: LOT:
619 456-5535
REMARKS: BJN/RON/484-8663 INSPECTOR
SPECIAL INSTRUCT:
TOTAL TIME:
CD LVL DESCRIPTION ACT COMMENTS
19 ST Final Structural
29 PL Final Plumbing / 39 EL Final Electrical
49 ME Final Mechanical
*** INSPECTION HISTORY *****
DATE DESCRIPTION ACT INSP COMMENTS
012497 Interior Lath/Drywall AP PY
011797 Frame/Steel/Bolting/Welding AP PY
011797 Rough Electric AP PY
010697 Ftg/Foundation/Piers AP PD SLAB
121996 Compliance Investigation PA PY MEET & CONFER
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619) 560-1468
~5_ - ~, DATE: ______
JURISDICTION:
PLAN CHECK NO: SET:
PROJECT ADDRESS:79
PROJECT NAME:ó,PO ,,4J
[]APPLICANT
[JPLAN CHECKER
FILE COPY []UPS
[]DESIGNER
E] The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
with the jurisdiction's building codes when minor deficien-
cies identified are resolved and
checked by building department staff.
U The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
Lj The check list transmitted herewith is for your information.
The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
U The applicant's copy of the check list has been sent to:
LI Esgil staff did not advise the applicant contact person that
plan check has been completed.
LI Esgil staff did advise applicant that the plan check has
been completed. Person contacted:_____________________
Date contacted: Telephone #
firm REMARKS:
za' Enclosures:
TI ON
GA El CM 11PC
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 02123
(619) 560-1468
DATE: 6 / / L-24
JURISDICTION: CITY OF CLSBAD
PLAN CHECK NO: 94 -3 SET:
PROJECT ADDRESS: ..794 WOOD WIND Q D
APPLICANT
CT
PLAN CHECKER
DFILE COPY o UPS
ODESIGNER
PROJECT NAME: s HoL LAD '( S EPAi)ITfa/'./
: The plans transmitted herewith have been corrected where
J necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
with the jurisdicipn's building codes when minor deficien-
cies identified are resolved and
checked by building deoartment staff.
-
The plans transmitted herewith have significant deficiencies EU identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
L The check list transmitted herewith is for your information.
The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
E]The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
Esgil staff dId not advise the applicant contact person that
plan check has been completed.
Esgil staff did advise applicant that the plan check has
been completed. Person contacted:
Date contacted:
Telephone
OM REMARKS: r
r
By: >,4\/ I D 0 Enclosures:
ESGIL CORPORATION
LIGA 11CM 11PC
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619) 560-14-68
DATE: 31 za.
JURISDICTION: CARLSBAD
PLAN CHECK NO: 94 3 -1-
PROJECT ADDRESS.:—.2 -7 ?4 k,100d In/,
APPL
JURISDIC"
tiPLAN
FILE COPY
UPS
fl DES IGNER
PROJECT NAME: Po . Hc2LLAl AIr/otq
, The plans transmitted herewith have been ..corrected where
Li necessary and substantially corrDly with the jurisdiction's
building codes.
The Dians transmitted herewith will substantially comply
with the jurisdiction's-building codes when minor deficien-
cies identified are resolved and
checked by building deDartment staff.
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a comolete recheck.
wi The check list transmitted herewith is for your information.
The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
.''he applicant's copy of the check list has been sent to:
gar acc'iic CB
BM Esgil staff did not advise the applicant contact person that
plan check has been completed.
Esgil staff did advise applicant that the plan check has
been completed. Person contacted:
Date contacted: Telephone
LI REMARKS:
By: ?VD 'fAO Enclosures:
ESGL CORPORATION 3-
UGA El CM C1 PC
ell
PLAN CHECK NO:
JURISDICTION:CITYOFCARLSBAD
TO: so
S-c)r LJqy
ENCLOSURES:
PROJECT ADDRESS:""794 Wood N1'.icj tL)
FLOOR AREA: Apo _5 /7 5
STORIES: /
HEIGHT:
FOREWORD: PLEASE READ
Plan check is limited to technical
requirements contained in the Uniform
Building Code, Uniform Plumbing Code,
Uniform Mechanical Code, National
Electrical Code and state laws regulating
energy conservation, noise attenuation
and access for the handicapped. The plan
check is based on regulations enforced by
the Building Inspection Department. You
may have other corrections based on laws
and ordinances by the Planning
Department, Engineering Department or
other departments.
Present California law mandates that
residential construction comply with
Title 24 and the following model codes:
1991 UBC (eff. 8/14/92)
1991 UPC (eff. 8/14/92)
1990 NEC (eff. 7/1/91)
1991 UNC (eff. 8/14/92)
The above regulations apply to
residential construction, regardless of
the code editions adopted by ordinance.
REMARKS:
PLAN CORRECTION SHEET
CITY OF CARLSBAD
SINGLE FAMILY AND DUPLEX DWELLINGS
Date plans received by jurisdiction:
Date plans received by Esgil Corporation
The circled items listed need
clarification, modification or change.
All items have to be satisfied before the
plans will be in conformance with the
cited codes and regulations. Per Sec.
303(c), 1991 Uniform Building Code, the
approval of the plans does not permit the
violation of any state, county or city
law.
To soeed uo the recheck process, note on
this list (or a copy) where each
correction item has been addressed i.e.,
plan sheet, specification, etc. Be sure
to enclose the marked up list when you
submit the revised plans.
Date initial plan check completed:
By: D/4
Applicant contact person:
toLo. Telephone:_ó'Z?-646'?( -e-)
NOTE: PAGE NUMBERS ARE NOT IN SEQUENCE AS PAGES RAVING NO ITEMS NEEDING CORRECTIONS WERE DELETED.
List No. 2, Carlsbad Single Family Dwelling and Duplex With All Supplements. (1991 U2C)
PLANS
Please make all corrections on the
original tracings and submit two new
sets of prints, to:
Esgil Corporation, 9320 Chesapeake
Drive, Suite #208, San Diego,
California 92123,
(619) 560-1468.
Please make all corrections on the
I original tracings and submit two new
/ sets of prints, to:
The jurisdiction's building
department.
Indicate on the Title Sheet of the
plans the name of the legal owner and
name of the person responsible for the
preparation of the plans.
Section 302(a)7.
4. All sheets of plans must be signed by
the person responsible for their
preparation. (California Business and
Professions Code)
j. Plans, specifications and calculations
shall be signed and sealed by the
California state licensed engineer or
architect responsible for their
preparation, for plans deviating from
conventional wood frame construction.
Specify expiration date of license.
(California Business and Professions
Code)
p'. Specify on the Title Sheet of the
plans the gross floor area of each
element of this project, including
dwelling, garage, carport, patio, deck
and balcony. Section 302(d).
7. Provide a statement on the Title Sheet
of the plans that this project shall
comply with Title 24 and the 1991 UBC,
UMC and UPC and 1990 NEC.
. Submit fully dimensioned plot plan,
drawn to scale, showing location,
size, and uses of all existing and
proposed structures on the lot.
Identify property lines and show lot
dimensions and all easements. Section
302(d).
Indicate distance from property lines
to the proposed building. Section
302(d).
1. On the cover sheet of the plans,
specify any items requiring special
inspection, in a format similar to
that shown below. Section 302(c).
REQUIRED SPECIAL INSPECTIONS
In addition to the regular
inspections, the following checked
items will also require Special
Inspection in accordance with Sec.
306 of the Uniform Building Code.
ITEM REQ. IF
CHECKED
SOILS COMPLIANCE
PRIOR TO
FOUNDATION INSP.
STRUCTURAL CONCRETE
OVER 2500 PSI
PRESTRESSED STEEL
FIELD WELDING
HIGH STRENGTH BOLTS
EXPANSION ANCHORS
SPECIAL MASONRY
SPRAYED-ON FIRE
PROOFING
PILES /CAI SSNS
DESIGNER-SPECIFIED
OTHER
11/18/93 2
Show on the title sheet all
structures, pools, walls, etc.
included under this application.
Any portion of the project shown on
the site plan that is not included
with the building permit application
filed should be clearly identified
as "not included."
i. Clearly show if the lower level is
/ a basement or a story, based on the
definitions in Sections 403 and 420.
Plot the finish grade (as defined)
on the elevations and dimension the
distance to the floor above, for
story determination.
FIRE PROTECTION
l. Exterior walls closer than 3 feet to
/ property lines shall be one-hour
I rated construction and have no
openings. Table 5-A.
id. Exterior walls closer than 3 feet to
I a property line shall have 30 inch
parapets when the floor area per
floor exceeds 1,000 square feet. See
Section 1710 for possible exception.
lj. Projections, including eaves, may
f not extend more than 12 inches into
the 3 foot setback from the property
line. Section 504(b).
Eaves over required windows shall be
1 not less than 30 inches from the
side and rear property lines.
Section 504(a).
1/. Projections, including eaves, shall
I be one-hour fire-resistive
construction, heavy timber or of
noncombustible material if they
project into the 3' setback area
from the property line. Section
1711.
34. Plastic skylights shall not be
f installed within that portion of a
roof located within a distance to
property line where openings in
exterior walls are prohibited or
required to be protected. Section
5207 (a) 7.
19. Show locations of permanently wired
smoke detectors with battery backup:
a Inside each bedroom.
Centrally located in corridor or
area giving access to sleeping
rooms.
c On each story.
In the basement, if part of the
dwelling unit.
When sleeping rooms are upstairs,
at the upper level in close
proximity to the stair.
In rooms adjacent to hallways
serving bedrooms, when such rooms
have a ceiling height 24 inches
or more above the ceiling height
in the hallway.
NOTE: Detectors shall sound an alarm
audible in all sleeping areas of the
unit. Section 1210
20 When the valuation of a room
addition or repair exceeds $1,000,
or when sleeping rooms are created,
smoke detectors shall be provided
per item 19 above, except that smoke
detectors added at existing
construction need only be battery
powered. Section 1210.
GENERAL RESIDENTIAL REQUIREMENTS
2J. Habitable rooms, other than
/ kitchens, shall contain at least 70
square feet of floor area. At least
one room shall have not less than
120 square feet of floor area.
Section 1207 (b)
2. No habitable room, other than a
/ kitchen, shall be less than 7'0" in
any dimension. Section 1207 (c)
Sleeping rooms shall have a window
/ or exterior door for emergency exit.
Sill height shall not exceed 44"
above the floor. The window must
have an openable area of at least
5.7 square feet with the minimum
openable width 20" and the minimum
openable height 24". Section 1204.
Basements in dwelling units shall
/ comly with the above (even if not
designated as sleeping rooms)
Section 1204.
11/16/93 3
2 Window area must be at least 1/10 of
/ the floor area and a minimum of 10
square feet per Section 1205 (b)
Appears to be deficient in
Openable window area in habitable
rooms must be 1/20 of the floor area
and a minimum of 5 square feet. In
bathrooms, laundry rooms and similar
rooms, 1/20 of area is required and
minimum is 1.5 sq. ft. Section 1205
(c)
2. At least 1/2 of the common wall must
be open and have an opening not less
than 25 sq. ft., nor one tenth of
the floor area of the interior room,
if light and ventilation is being
supplied from an adjacent room.
Section 1205 (a)
2,. Required windows shall not open into
a roofed porch unless the ceiling
height is at least 7 feet, the
longer side is at least 651 open,
and the porch abuts a street, yard
or court.
Section 1205 (a)
Provide mechanical ventilation
capable of providing five air
changes per hour in bathrooms, water
closet compartments, laundry rooms
and similar rooms if required
openable windows are not provided.
Section 1205 (c)
30 Note that the discharge point for
exhaust air will be at least 3 feet
from any opening into the building.
Section 1205(c).
31 Ductless fans cannot be used in
bathrooms if a tub or shower is
present. Section 1205(c).
Show that ceiling height for
I habitable rooms is a minimum of
7'611 . Section 1207 (a).
3A. Show ceiling height for laundry
/ rooms, hallways, corridors, and
/ bathrooms is a minimum of 7'011 .
Section 1207 (a)
,( Dimension on the plans 30" clear
width for water closet compartments
and 24" clearance in front of water
closet. Section 511 (a)
3/ Show safety glazing in the following
/ locations, per Section 5406(d):
Where the nearest edge of glazing
is within a 24-inch arc of either
side of a door in a closed
position (unless there is an
intervening wall between the door
and the glazing or if the glazing
is 5'-0" or higher above the
walking surface)
Glazing greater than 9 square
feet with the bottom edge less
than 18" above the floor and the
top edge greater than 36" above
the floor (unless the glazing is
more than 36" horizontally away
from walking surfaces or if a
complying protective bar is
installed)
Glazing in shower and tub
enclosures (including windows
within 5 feet of tub or shower
floor)
/6- Walls and floors separating units in
a duplex shall be of one-hour fire-
resistive construction. Provide
details of the assemblies. Section
1202(b).
3/. A mezzanine is an intermediate floor
/ and may not have a floor area
I exceeding 33 1/3 percent of the
total floor area in the room below.
The mezzanine floor must have a
clear height of 7 feet, above and
below, and must have the long side
open to the room below except for
posts and protective walls or
railings not exceeding 44" in
height. Section 1717.
3/ The loft you show does not comply as
/ a mezzanine floor and is, by Uniform
/ Building Code definition, a story.
Section 1717.
34. Dwellings used for daycare for 7 to
/ 12 children shall comply with the
special requirements in Chapter 12
of Title 24.
<P
11/16/93 4
12. Exterior stairways shall not project 6/
/ into the 3 foot setback from the
property lines. Section 3306 (m)
5J. The walls and soffits of the
/ enclosed usable space under interior
" stairs shall be protected on the
enclosed side as required for one-
hour fire-resistive construction. /
Section 3306 (1) .
Within units, show that corridors
/ have a minimum width of 36 inches.
Section 3305 (b) . /
6
ROOFING
Specify roof slope.
Roof slope is not adequate for roof
/ type specified. Table 32-B, D and
E.
5A. Specify roof material and
/ application. Chapter 32.
5,. Specify I.C.B.O. or U.L. approval
/ number for roof materials not
I covered in U.B.C., e.g., tile, etc.
Section 107.
/9
Specify minimum 1/4 inch per foot
roof slope for drainage or design to
support accumulated water. Section
3207 (a) and Section 2305 (f)
GA. Show roof drains and overflows.
I Section 3207.
6/. Provide skylight details to show
( compliance with Sections 3401 and
5207 or provide I.C.B.O. approval
number.
64. Plastic skylights must be separated
I from each other by at least 4 feet,
unless they are over the same room
and their combined area does not
exceed 100 square feet (or 200
square feet if the plastic is a
"CCI" material). Section 5207 (a) 6.
6. Show attic ventilation. Minimum
vent area is 1/150 of attic area (or
1/300 of attic area if at least 50's
of the required vent is at least 3
feet above eave vents or cornice
vents). Show area required and
area provided. Section 3205 (c)
Note on the plans: "Attic
ventilation openings shall be
covered with corrosion-resistant
metal mesh with mesh openings of
1/4-inch in dimension." Section
3205(c)
CONCRETE AND MASONRY
Provide fireplace construction
details or note construction to be
per attached fireplace standard
drawing. Chapter 37.
Show anchored veneer support and
connections attached to wood in
Seismic Zones 3 and 4, comply with
Section 3006 (d)l and Section 2515
(a) . Show ties and 49 wire in
horizontal joints, etc.
6/. Show height and construction details
/ of all masonry walls. Chapters 24
and 26.
6/. Show floor and roof connections to
/ masonry and concrete walls.
Connection shall resist 200 pounds
per lineal foot or the actual design
load, whichever is greater. Cross
grain tension or bending in wood
ledgers is not permitted. Section
2310.
GARAGE AND CARPORTS
6/. Garage requires one-hour fire
I protection on the garage side of
walls and ceiling common to the
dwelling. Table 5-B, Section 503
(d).
All elements supporting floor above
/ garage, including walls supporting
floor joists, must have one-hour
fire-resistive protection on the
garage side. Section 503 (b)
7/ Show a self-closing door, either 1-
/ 3/8" solid core or a listed 20-
minute assembly, for openings
between garage and dwelling.
Section 503 (d)
72. Garages are not permitted to open
into a room used for sleeping
purposes. Section ll04.C1vv;Ie. c
tc,ov -fz> ~e'yr,+e. +)?e. edDoh)
''11/17/93 6
7)3. An occupancy separation is not The utility trenches have been
required between carport and properly backfilled and
residence, provided the carport is compacted, and
open on two or more sides and has no
enclosed uses above. Section 503 The foundation excavations, the
(a) Exception 3. soils expansive characteristics
7J1. Show garage framing sections, size
and bearing capacity conform to
the soils report."
of header over garage opening,
lateral cross bracing at plate line, 0. Provide a letter from the soils
method bracing garage front and I engineer confirming that the
holddowns if reauired. Chapter 23. foundation plan, grading plan and
specifications have been reviewed
NOTE: Maximum shear panel height-to- and that it has been determined that
width ratio is 3-1/2 to 1 for the recommendations in the soils
plywood. Table 25-I. report are properly incorporated
into the construction documents
G
Doors may open into the garage only (when required by the soil report).
if the floor or landing in the
garage is not more than one inch l. Show height of all foundation walls.
lower than the door threshold. Chapter 23.
Section 3304 W .
/2. Show height of retained earth on all
7/6. Provide an 18" raised platform for foundation walls. Chapter 23.
any FAU, water heater, or other
device in the garage which may 3. If cut or fill slopes exist, show
generate a flame or spark. U1C / distance from foundation to edge of
Section 508, UPC Section 1310 (a) . cut or fill slopes and show
steepness and heights of cuts and
FOUNDATION REQUIREMENTS fills. Chapter 29.
7A. Per soils report, note on the plan 8/. Note on plans that wood shall be 6"
the soils classification, whether or / minimum above finish grade. Section
not the soil is expansive and note 2907 (a)
the allowable bearing value. / Section 2905 (c). . Note on plans that surface water
/ will drain away from building and
7. The foundation plan does not comply show drainage pattern and key
with the soils report elevations. Section 2905 (f).
recommendations for this project. /
Please review the report and modify 8. Dimension foundation per U.B.C.
design, notes and details as I Table 29A:
required to show compliance:_
Floors Footing
Supported* Stemw1 1 Width Depth Thickness
7. The soils engineer recommended that
he/she review the foundation
excavations. Note on the foundation
plan that "Prior to the contractor
requesting a Building Department
foundation inspection, the soils
engineer shall advise the building
official in writing that:
1. The building pad was prepared in
accordance with the soils report,
1 6" 12" 12." 6"
2 8" 15" 18" 7"
3 10" 18" 24" 8"
*Foundations may support a roof in
addition to the floors. Where only a
roof is supported, use foundation for one
floor.
8/. Show foundation sills to be pressure
/ treated, or equal. Section 2516 (c)
/ 3.
11/17/93 7
4. Columns and posts located on
concrete or masonry floors or decks
exposed to the weather or to water
splash or in basements and which
support permanent structures shall
be supported by concrete piers or
metal pedestals projecting it
minimum above floors unless
approved wood of natural resistance
to decay or treated wood is used.
Section 2516 (c) 4.
1/5. Individual concrete or masonry
piers shall project at least 8
inches above exposed ground unless
the columns or posts which they
support are of approved wood of
natural resistance to decay or
treated wood is used.
Section 2516 (c) 4.
1/6. Show location of attic access with
a minimum size of 22"x30", unless
the maximum vertical headroom
height in the attic is less than
30 1 . Access must be provided to
each separated attic area, shall be
located in a hallway or other
readily accessible location and 300
headroom clearance is required
above the opening. Section
3205(a).
1i. Detail truss layout for 30" x 30"
/ attic access, if required for
equipment in the attic and detail
30" x 30" clearance through truss
webs.
1. Specify plywood and/or particle
/ board thickness, grade and panel
span rating. Table 25-S.
44. When roof pitch is less than 3:12,
/ design ridge as a beam. Section
2517 (h)
1. Ridges, hips, and valleys shall be
/ at least one size larger than
supported rafters. Section 2517
/ (h) 3.
/31. In open beam construction, provide
strap ties across the beams at the
ridge support. Section 2501 (b)
1/2. If foundation cripple wall studs
/ are less than 14" high, framing
shall be solid blocking, or
sheathed with plywood. Section
2517 (g) 4.
3. Cripple wall studs exceeding 4 feet
I in height shall be 3 inch by 4 inch
or 2 inches by 6 inches when
supporting 2 stories. Section 2517
(g) 4.
134 Note on the plans that 'all
weather-exposed surfaces shall have
a weather-resistive barrier to
protect the interior wall covering
and that exterior openings shall be
flashed in such a manner as to make
them weatherproof". Section 1708.
MECHANICAL (UNIFORM MECHANICAL CODE)
All heating, ventilating, and cooling
systems and appliances shall comply with
the Uniform Mechanical Code.
l. Show the size, location and type of
/ all heating and cooling appliances
or systems.
l. Every dwelling unit shall be
7 provided with heating facilities
capable of maintaining a room
temperature of 70 degrees F. at 3
feet above the floor in all
habitable rooms. Show basis for
compliance. UIBC, Sec. 1212.
7. Note on the plans that the FAU
/ closet or alcove must be 12 inches
wider than the furnace or furnaces
being installed. UMC Section 704.
,
318. Show minimum 30" deep unobstructed
working space in front of furnace.
Section 505, UMC.
9. Furnace shall not be installed in
/ any bedroom, bathroom or in a
closet or confined space with
access only through such room
unless specified as direct vent
appliance, enclosed furnace or
electric heating appliance. Section
704, UMC.
14/. Show source of combustion air to
/ furnace, per Chapter 6, UMC.
11/17/93 10
Show access to the attic containing
/ equipment to be minimum 30 inches
by 30 inches. The opening may be 22
inches by 30 inches if the
equipment can be removed through
such opening. Section 708, U'iC.
1712. Note that passageway to the attic
furnace shall be unobstructed and
have continuous solid flooring not
less than 24 inches wide, hot more
than 20 feet in length through the
attic. Section 708, UMC.
/3 - Show permanent electrical outlet
and lighting fixture controlled by
a switch for furnace located in
attic or underfloor space. Section
708 & 709, UNC.
V4. Show details to comply with Section
709 for furnace under the floor, or
Section 710 for roof or outside
furnace.
115. Show I.C.B.O. approval number for
/ prefab fireplace. Show height of
chimney above roof per I.C.B.O.
approval or Table 37-B.
l%. Note on the plans that approved
/ spark arrestors shall be installed
on all chimneys. Section 3703(h).
147 Note on plan: Gas vents and non-
combustible piping in walls,
passing through three floors or
less, shall be effectively draft
stopped at each floor or ceiling.
UBC, Section 1706 (c)
4 . Provide dryer vent to outside. The
' maximum length is 14 feet with two
90-degree elbows. UMC, Section
1903.
ELECTRICAL (NATIONAL ELECTRICAL CODE)
All wiring shall comply with the National
Electrical Code.
1/9. Show on the plan the amperage of
/ the electrical service, the
/ location of the service panel and
the location of any sub-panels. If
service is over 200 amps, submit
single line diagram, panel schedule
and load calculations.
150 Note on the plans that receptacle
outlet locations will comply with
1990 NEC Art. 210-52(a).
Show on the plans that countertop
receptacle outlets comply with 1990
NEC Art. 210-52(c), which reads as
follows:
In kitchens and dining areas of
dwelling units a receptacle outlet
shall be installed at each counter
space wider than 12 inches.
Receptacles shall be installed so
that no point along the wall line
is more than 24 inches measured
horizontally from a receptacle
outlet in that space. Island and
peninsular countertops 12 inches or
wider shall have at least one
receptacle for each four feet of
counter top. Counter top spaces
separated by range tops,
refrigerators, or sinks shall be
considered as separate counter top
spaces. Receptacles rendered
inaccessible by appliances fastened
in place or appliances occupying
dedicated space shall not be
considered as these required
outlets.
Dwelling Unit Receptacle Outlets
Counter Tops
270-52(c)
0
o 0 0
4' Flet GF
iH.
rilchen or
eel Nrirgksa 'S
/52. Show on the plan that receptacle
/ outlets in hallways comply with
1990 NEC Art. 210-52(h), which
reads as follows:
For hallways of 10 feet or more in
length at least one receptacle
outlet shall be required.
11/17/93 11
1,0
Show on the plan that ground-fault
circuit-interrupter protection
complies with 1990 NEC Art. 210-8,
which reads as follows:
All 125-volt, single-phase, 15- and
20- ampere receptacles installed in
bathrooms, garages, basements,
outdoors and within 6 feet of a
kitchen sink.
PLUMBING (UNIFORM PLUMING CODE)
Show water heater size, type and
/ location on plans. UPC, Section
/ 1301.
14. Note on the plans that "combustion
/ air for fuel burning water heaters
will be provided in accordance with
the Uniform Plumbing Code".
l6. Provide adequate barrier to protect
/ water heater from vehicle damage.
An 18" platform for the water
heater does not satisfy this
requirement. UPC, Section 1310.
l. Show T and P valve on water heater
/ and show route of discharge line to
exterior. UPC, Section 1007 (e)
Show that water heater is
/ adequately braced to resist seismic
forces. UPC, Section 1310.
Show shower stall can accommodate a
/ 30" circle and has a minimum floor
area of 1,024 sq. in. UPC 909 (d)
161. New water closets and associated
flushometer valves, if any, shall
use no more than 1.6 gallons per
flush and shall meet performance
standards established by the
American National Standards
Institute Standard A112.19.2, and
urinals and associated flushometer
valves, if any, shall use no more
than one gallon per flush and shall
meet performance standards
established by the American
National Standards Institute
Standard A112.19.2. H & S Code,
Section 17921.3(b).
NOISE INSULATION (DUPLEXES)
l6A. Show details of duplex common
/ (party) walls and floor/ceiling
assemblies to achieve a Sound
Transmission Class (STC) rating in
walls of 50 decibels and an Impact
Insulation Class (IIC) rating on
floor/ceiling of 50 decibels.
Title 24.
Show how penetrations of assemblies
for piping, electrical devices,
recessed cabinets, bathtubs,
soffits, or heating ventilating, or
exhaust ducts shall be sealed,
lined, or insulated to maintain
required sound transmission rating.
Title 24.
Provide insulation in walls and
ceiling to achieve STC of 50
between garage and living area if
garage use is not controlled by
resident. Title 24.
ENERGY CONSERVATION
NOTE: Plans submitted after January 1,
1993 must comply with the new energy
standards.
S.
Provide plans, calculations and
/ worksheets to show compliance with
current energy standards.
l. The regulations require a properly
/ completed and properly signed Form
CF-1R to be either imprinted on the
plans, taped to the plans or
"sticky backed" on the plans, to
allow the building inspector to
readily compare the actual
construction with the requirements
of the approved energy design.
1p4. All energy items shown on the plans
/ must be in agreement with the
information shown on the properly
completed Form CF-1R.
73.
1A6. Fuel combustion water heater shall
/ not be installed in clothes
/ closets, in a bathroom or bedroom, 1q4.
or in a closet opening into
bathroom or bedroom. UPC, Section
1309.
PC, Ad // 4 (/2 ,j si,
11/17/93 12
1 '8. Specify on the building plans all
/ of the mandatory energy
I conservation requirements as
listed on the enclosure titled,
"Mandatory Measures Checklist."
16,6. Show the make, model and
/ efficiency of the space heating
I (or cooling) system.
r/o. For room additions, show
/ compliance with the energy
standards. See attached.
71 Provide fluorescent general
lighting (40 lumens per watt) in
kitchcn(3) and bathrooms.
172 Provide a note on the plans
stating "All new glazing
(fenestrations) will be installed
with a certifying label attached,
showing the U-value."
/3 -
CARLSBAD S.F.D. & DUPLEX SUPPLEMENT
Energy conservation design should
be for Zone 7.
174. For gas piping under slabs that
/ serve kitchen island cooktops, see
the attached Policy 91-46 for
special sleeve and clean-out
requirements.
1)15. New residential units must be pre-
plumbed for future solar water
heating. Note that two roof jacks
must be installed where the water
heater is in the one story garage
and directly below the most south
facing roof (City Ordinance No.
/
8093)
Note that two 3/4" copper pipes
/ must be installed to the most
/ convenient future solar panel
location when the water heater is
not in a one story garage and is
not directly below the most south
facing roof. (City Ordinance No.
8093)
1/77. All piping for present or future
/ solar water heating must be
insulated when in areas that are
not heated or cooled by mechanical
means (city policy)
1/8. Incorporate the waterproofing
details, on the attached Policy
80-8, where interior living space
occurs below grade at the masonry
wall (s)
1 9. Show on the Title Sheet on the
/ plans, the information required by
the attached Developmental
Services Sheet 112383.
1
0. All new residential buildings,
/ including additions, require a
I soils report. Please submit two
copies. Exception: If a room
addition is limited to one story
and 1000 sq. ft. in area, then a
soils report is not required.
Esgil Corporation will advise the
City to place their soils notice
stamp on the plans.
l'l. All structures require a Class B
/ roof covering, except room
additions. If a room addition
covers all of the existing
building (2nd story addition),
then the above exception doesn't
/ apply.
l2. City Ordinance 9792 requires two
/ parking spaces/unit with clear
area of 20'x20' i.e. no washing
machines, etc. Show compliance.
18/3. Overflow roof drains shall
/ terminate in an area where they
will be readily visible and will
not cause damage to the building.
If the roof drain terminates
through a wall, the overflow drain
shall terminate 12" minimum above
the roof drain. Policy 84-35.
MISCELLANEOUS
14. Please see additional corrections,
or remarks, on the following page.
G
To speed up the recheck process,
note on this list (or a copy)
where each correction item has
been addressed, i.e., plan sheet,
note or detail number, calculation
page, etc.
G
Please indicate here if any
changes have been made to the
plans that are not a result of
corrections from this list. If
there are other changes, please
briefly describe them and where
they are located in the plans.
Have changes been made to the
plans not resulting from this
correction list? Please indicate:
Yes No
11/30/93 S 13
Date Jurisdiction_çA1LD
Prepared by
VALUATION AND PLA N CHECK FEE
E] Bldg. Dept.
C] Esgil
PLAN CHECK NO._4- 263
BUILDING ADDR ESS
APPLICANT/CONTACT OL sPH0NE NO. Z7 ~6 CpTorJ
BUILDING OCCUPANCY DESIGNER PHONE 42_i- 74I
TYPE OF CONSTRUCTION V - CONTRACTOR PHONE____________
BUILDING PORTION BUILDING AREA VALUATION
IULTI?LIER
VALUE
ADT)ITUfl4
Air ConditioninE
Commercial
Residential
Res. or Comm.
Fire_SDrinklers
Total Value
i'n+
Buildirid Permit Fee. $_ ..2.d.'4S_
Plan Check Fee S
COti M E N T S
SHEET OF / 12/87
Carlsbad
4L.IFO E
BUILDING PLANCHECK CHECKLIST
DATE: PLANCHECK NO. c1e
BUILDING ADDRESS: -1/i iri..' -.
PROJECT DESCRIPTION:
ASSESSOR's PARCEL NUMBER:" /J é Lf3/- di EST. VALUE f?7
ENGINEERING DEPARTMENT
APPROVAL
The item you have submitted for review has been
approved. The approval is based on plans,
information and/or specifications provided in your
submittal; therefore any changes to these items
after this date, including fie!d modifications, must
be reviewed by this office to insure continued
conformance with applicable codes. Please review
carefully all comments attached, as failure to
comply with instructions in this report can result in
suspension of permit to build.
1st CHECK By: Date:_______
2nd CHECK By: Date:________
3rd CHECK By: Date:________
DENIAL
Please see the attached report of deficiencies
marked with 0. Make necessary corrections to
plans or specifications for complianceL with
applicable codes and standards. Submit corrected
plans and/or specifications to this office for review.
By: Date:_________
By: Date:_________
By: Date:_________
ATTACHMENTS
[3 Dedication Application
El Dedication Checklist
O Improvement Application
O Improvement Checklist
O Future Improvement Agreement
O Grading Permit Application
O Right of Way Permit Application
El Sewer Fee Information Sheet
CONTACT PERSON
NAME:
ADDRESS:
PHONE:
A-4
P:\D0CS\CHKLSTBP0001.FRM REV 12/17/93
2075 Las Palmas Dr. • Carlsbad, CA 92009-1576. (619) 438-1161 • FAX (619) 438-0894
I
BUILDING PLANCHECK CHECKLIST
Js2nd,/
SITE PLAN
3rdV 0 1. Provide a fully dimensioned site plan drawn to scale. Show:
A. North Arrow D. Property Lines Easements / B. Existing & Proposed Structures E. Easements
/
C. Existing Street Improvements F. Right-of-Way Width & Adjacent Streets
12 0 2. Show on site plan:
/ A. Drainage Patterns . C. Existing Topography
/ B. Existing & Proposed Slopes
E!( 0 0 .3. Show on a section drawing or include a note stating that there is a minimum of 6"
zo
difference between the finished flOor and the finished grade elevation adjacent to the
structure.
0 4. Include note: "Surface water to be directed away from the building foundation at a 2%
gradient for no less than 5' or 2/3 the distance to the property line (whichever is less)."
[Per 1985 UBC2907(d)5].
1, On graded sites, the top of any exterior foundation shall extend above the elevation / . of the Street gutter at point of discharge or the inlet of an approved drainage device
/ a minimum of 12 inches plus two percent" (per 1990 UBC 2907(d)5.).
12 0 5. Include on title sheet
. Site address
Assessor's Parcel Number
Legal Description
For commercial/industrial buildings and tenant improvement projects, include: Total
building square footage with the square footage for each different use, existing sewer
permits showing square footage of different uses. (manufacturing, warehouse, office,
etc.) previously approved.
EXISTING PERMIT NUMBER DESCRIPTION
P:\DOCS\CHKLSflBP0001.FRM Page 1 of 4 REV 12/17/93
BUILDING PLANCHECK CHECKLIST
DISCRETIONARY APPROVAL COMPLIANCE
2nd,/3rd/ El 0 6. Project does not comply with the following Engineering Conditions of approval for 41~1 Project No.
Conditions were complied with by: Date:__________________
DEDICATION REQUIREMENTS
0 0 7. Dedication for all street Rights-of-Way adjacent to the building site and any storm
drain or utility easements on the building. site is required for all new buildings and for
remodels with a value at or exceeding $______________ -pursuant to Code Section
18.40.030.
Dedication required as follows:
Attached please find an application form and submittal checklist for the dedication
process. Provide the completed application form and the requirements on the
checklist at the time of resubmittal.
Dedication completed by Date:___________
IMPROVEMENT REQUIREMENTS
El 0 0 8a. All needed public improvements upon and adjacent to the building site must be
constructed at time of building construction whenever the value of the construction
exceeds $ -pursuant to Code Section 18.40.040.
Public improvements required as follows:
Please have a registered Civil Engineer prepare appropriate improvement plans and
submit them together with the requirements on the attached checklist for a separate
plancheckprocess through the Engineering Department. Improvement plans must be
approved, appropriate securities posted and fees paid prior to issuance of permit.
Attached please find an application form and submittal checklist for the public
improvements, requirements. Provide the completed application form and the
requirements on the checklist at the time of resubmittal.
Improvement Plans signed by: S Date:
P:\DOCS\cHKLST\BP0001.FRM Page 2 of 4 REV 12/17/93
BUILDING PLANCHECK CHECKLIST
1 SW 2ndv' 3rd./ DOD •8b. Construction of the public improvements may be deferred pursuant to code Section
18.40. Please submit a recent property title report or current grant deed. on the
property and processing fee of $____________________ so we may prepare the
necessary Future Improvement Agreement. This agreement must be signed, notarized
and approved by the City prior to issuance of a Building Permit.
Future public improvements required as follows:_____________________________
Improvement Plans signed by: Date:
... 8c. Enclosed please find your Future Improvement Agreement. Please return signed and
notarized Agreement to the Engineering Department.
Future Improvement Agreement completed by:_______________________________
Date:
0 8d. No Public Improvements required. LSPECIAL NOTE: Damaged or defective
improvements found adjacent to building site must be repaired to the satisfaction of
the City Inspector prior to occupancy.
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for a grading permit are found in Section 11.06.030
of the Municipal Code.
U 0 0 9a. Inadequate information available on Site Plan to make a determination on grading
requirements. Include accurate grading quantities (cut, fill import, export).
O 0 0 9b. Grading Permit required. A separate grading plan prepared by a registered Civil
Engineer must be Submitted together with the completed application form attached.
NOTE: The Grading Permit must be issued and rough grading approval obtained prior
to issuance of a Building Permit.
Grading Inspector sign off by: bate:
U 0 9c. No Grading Permit required.
BUILDING PLANCHECK CHECKLIST
P:\DOCS\CHKLST\BP0001.FRM Page 3 of 4 REV 12/17/93
is / 2fldv' 3rd../
/DD
MISCELLANEOUS PERMITS
10 A RIGHT-OF-WAY PERMIT, is required to do work in City Right-of-Way and/or
private work adjacent to the public Right-of-Way. Types of work include, but are not
limited to:. street improvements, trees, driveways.
A separate Right-of-Way' permit issued by the Engineering Department is required for
the following: .
Please complete attached Right-of-Way application form and return to the Engineering
Department together with the requirements on the attached Right-of-Way checklist, at
the time of resubmittal. .
U 0 11. A SEWER PERMIT is required concurrent with the building permit issuance. The fee
is noted in the fees section on the following page.
0 0 12. INDUSTRIAL WASTE PERMIT is required. Applicant must complete Industrial
Waste Permit Application Form and submit for City approval prior to issuance of a (r Permit.
Industrial' waste permit accepted by: ' Date:
P:\DOCS\CHKLSfl13P0001.FRM Page 4 of 4 REV 12/17/93
PLANNING CHECKLIST 1 77..
Plan Check No. Address 27?g Jcvi"ici' .
Planner DAVID RICK Phone 438-1161 ext. 4328
(Name)
APN: /56 - °
Type of Project and Use
Zone rc Facilities Management Zone
CFD (in/out) #________________ circle (If property in, complete SPECIAL TAX CALCULATION
WORKSHEET provided by Building Department.)
I Legend
Item Complete
Item Incomplete - Needs your action
1, 2, 3 Number in circle indicates plancheck number where deficiency was
identified
U U Environmental Review Required: YES NO J TYPE
DATE OF COMPLETION:
Compliance with conditions of approval? If not, state conditions which require action.
ConditiOns of Approval
[?EJ U Discretionary Action Required: YES - NO Z TYPE
APPROVAL4/RESO. NO. DATE:
PROJECT NO.
OTHER RELATED CASES:
Compliance with conditions ofapproval? If not, state conditions which require action.
Conditions of Approval
~Io 0 California Coastal Commission Permit Required: YES - NO
DATE OF APPROVAL:
San Diego Coast District, 3111 Camino Del Rio North, Suite 200, San Diego, CA. 92108-1725
(619) 521-8036
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval
Fee required: YES NO O 0 Inclusionary Housing
(Effective date of Inclusionary Housing Ordinance - May 21, 1993.)
Site Plan:
ill 0 1. 'fully Provide a dimensioned site plan drawn to scale. Show: North
arrow, property. lines, easements, existing and proposed structures,
streets, existing street improvements, right-of-way width, dimensioned
setbacks and existing topographical lines.
310 0 2. Provide legal description of property, and assesso?s parcel number.
Zoning
0 1. Setbacks:
Front: Required Shown
Int. Side: Required Shown
Street Side: Required Shown
Rear: Required Shown
0 2. Lot coverage: Required _Shown
0 0 'rr 3. Height: Required "_'Iown 7 5orp eya51
0 4. Parking: Spaces Required Shown
/ Guest Spaces Required Shown
3/0 Additional Comments 'A5' hLI; Id" 4 -CurrPx4JV 54~)r'es, QA,
1J4(
L
IC
1)-t .(opoc4oaL &'c &r ar. of -tk.L 1 5,t- cRoor 15
o... b Ià .Jtic' (Mit.Pok co
•ec-1oA j). o' 4
pI.-.idkf.
0k. p&- 5 cfpo7. Pc/ ~ck) iJ 11+eror C6c. are
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE
PLNCK.FRM
[OIIy_.) i;jl.F]Øj1
MARCH 25, 1994
2794 WOODWIND ROAD
TO WHOM IT MAY CONCERN:
ON MARCH 14, 1994 FRANK DELAROSA SUBMITTED PLANS FOR 512 SQUARE
FEET OF REMODEL/ADDITION AT THE ABOVE ADDRESS AND PAID A
PLAN CHECK FEE OF.$185.00. HE WAS INFORMED ON MARCH 18TH BY
DAVID RICK, PLANNING TECHNICIAN, THAT HE COULD NOT EXPAND A
NON CONFORMING USE PER SECTION 21.48.080 OF CITY ZONING ORDINANCE.
MR. DELAROSA EXPLAINED THAT THE OWNER WAS RESPONDING TO A CODE
ENFORCEMENT VIOLATION AND WAS ATTEMPTING TO COMPLY AND
BRING THE ADDITION UP TO CODE. THE PLANS WERE RETURNED TO
MR. DELAROSA ON MARCH 28TH.
CL
DORIS COSMAN
BUILDING TECHNICIAN
2075 Las Palmas Drive Carlsbad, California 92009-1576 '• (619) 438-1161