HomeMy WebLinkAbout1425 YOURELL AVE; ; CBR2018-1533; PermitPERMIT REPORT
(äty of
Carlsbad
Print Date: 04/23/2020 Permit No: CBR2018-1533
Job Address: 1425 Yourell Ave
Permit Type: BLDG-Residential Work Class: Addition Status: Closed - Expired
Parcel No: 1560525100 Applied: 06/27/2018
Valuation: $ 343,993.25 Lot U: Issued: 11/07/2018
Occupancy Group: Project #: PermitFinal
U Dwelling Units: Construction Type Close Out:
Bedrooms: Inspector: PBurn
Bathrooms: Orig. Plan Check U: Final
Plan Check U: Inspection:
Project Title:
Description: ROPER: 1,497 SF ADDITION II REMODEL 1,503 SF// 151 SF BALCONY //462 SF DECK
Owner:
COOWNER BRIDGET & JIM HARPER
1425 Yourell Ave
CARLSBAD, CA 92008
FEE AMOUNT
BUILDING PERMIT FEE ($2000+) $1,492.20
BUILDING PLAN CHECK FEE (BLDG) $1,044.54
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL $66.00
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION $170.00
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL $92.00
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL $182.00
5B1473 GREEN BUILDING STATE STANDARDS FEE $14.00
STRONG MOTION-RESIDENTIAL $44.72
SWPPP INSPECTION FEE TIER 1 - Medium BLDG $246.00
SWPPP PLAN REVIEW FEE TIER 1 - MEDIUM
-
$56.00
Total Fees: $ 3,407.46 Total Payments To Date : $ 3,407.46 Balance Due: $0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal-Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees /exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
EXPIRED PERMIT
PERMIT HAS EXPIRED IN ACCORDANCE WITH C.B.C.
SECTION 106.4.4 AS AMENDED BY C.M.C.18.04.030
'-t .•z• IGNA1URE_-1 DATE S
Building Division
1635 Faraday Avenue, Carlsbad CA 92008-73141 760-602-2700 1 760-602-8560 f I www.carlsbadca.gov Page 1 of 1
THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: 1LANNING IENGINEERING BUILDING 0 FIRE 0 HEALTH 0 HAZMATIAPCD
'
Building Permit Application
1635 Faraday Ave., Carlsbad, CA 92008 City of
CdrIsbad. Ph: 760-602-2719 Fax: 760-602-8558
email: buildingcarlsbadca.gov
www.cailsbadca.gov
Plan Check No. (3 0 t23
Est. Value 7TjI.j3,g3. 5
Plan Ck. Deposit
Date /a /2.74
JOB ADDRESS I SUITE#/SPACE#/UNIT#
I
I APN
jç(Q-Ocz.-( -
CT/PROJECT It LOT It PHAS
I
ITS # BEDROOMS It BATHROO 11 !_ TENANT BUSINESS NAME CONSTR. TYPE
v 13
0CC. GROUP
iz.
DESCRIPTION OF WORK: Include Square Feet of Affected Area(s)
4-r'r 2-%47'5F 004;80 Pools
tc,i t-4US &'Eb3 F _ too rr4+411
PtQ . . I I 5 F
91>(I) i
AIR CoNDmONI( EXISTING USE I PROPOSED USE
- I 6 - 5
IRAGE (Sfl
k;)
PATIOS (S I
145'1 I
DECKS (S I FIREPE
YES ?NOD YESNOI
FIRE SPRINKLERS
NOtX
APPLICANT NAME
Prtnary Contact Alz
PROPERTY ONER NAME
Q6' J 4-
ADDRESS IM-3 MkY' 1 -(O( f() ADDRESS
j41( Aye-
CITY STATE ZIP
Q
CITY STATE ZIP
PHONE
i/oo Z1 1
FAX PHONE IFAX i/go ' I
EMAIL EMAIL R M1 C-a----
DESIGN PROFESSIONAL CONTRACTOR BUS. N4r, E
T'4A*-_u ,Q26Mt)
ADDRESS DDRESS P05 k',
CITY STATE ZIP CITY STATE ZIP
~A14 7,076
PHONE FAX PHO FAX
EMAIL EMAIL
ISTATE UC
.#
STATE UC.# CLASS ICOY BUS. U4
®aia 170®1
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
[1 I have and will maintain w ers' compe lion, as required by Section 3700 of the Labor Code, for the pert ance of the work for which this it is issued. My workers compen ion in uran er and policy
number are: Insurance C2?ti 1V6 fcA'_) (22 poiicy'J'4 &~' 7 gôh, Expiration Date _ /
This section need not be completed if the permit is for one hundred dollars ($100) or less. /
[J Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
California. WARNING: Failure to secure workers' compensation coy gels unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in
addition to the cost of compensation, damages as provided to ion 3706 of the Labor code, interest and attorney's fees.
CONTRACTOR SIGNATURE 4~4 - 0 AGENT DATE /CS/ "Z 3//53?
®c!z)()Q(e)oc®@rD 000, I hereby affirm that lam exempt from Contractor's License Law for the followin
is
ason:
[] I, as owner of the property or my employees with wages as their sole co tiori, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply loan owner of property who builds or imjo thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within on. completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). 01
I, as owner of the property, am exclusively contracting jtli't(nsed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
properly who builds or improves thereon, and con for such projects with contractor(s) licensed pursuant to the Contractor's License Law).
I am exempt under Section siness and Professions Code for this reason:
1. I personally plan to provide th ajor labor and materials for construction of the proposed properly improvement -]Yes DNo
2.1 (have! have not) sign n application for a building permit for the proposed work.
I have contracted w e following person (firm) to provide the proposed construction (include name address! phone / contractors' license number):
I plan to provide ortions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name! address phone contractors' license number):
5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name! address! phone! type of work):
PROPERTY OWNER SIGNATURE []AGENT DATE
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, arso requires nne
applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the
Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a
civil penalty of not more than five hundred dollars (
—j
$500}).
(®17@ 7W03 60G100() 90 ®OYO QWO(!®O)@ I20098 ®flY
Is the applicant or future building occupant required to submit 4 business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act?-4 rJ Yes D No
Is the applicant or future building occupant require([o obtain a permit from the air pollution control district or air quality management district? DYes 0 No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 Yes 0 No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
(®(!)(17O®1) ()®O(J@ (XS2
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender's Name Lender's Address
O€Jni7 O(POO®(Z)
IceitifjthatI have read the applicatlon and state thatthe above Information iscormc.tandthatthe information on the plans is accurate. I agree tocomplywtth all Cityordinancesand State laws relatingto bulldingconstniction.
I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA An OSHA permit is required for excavations over 50' deep and demolition or construction of structures over 3 stories in height
EXPIRATION: Every permit issued by the Building Official under the p ions of this Code shall exptreby limitation and become null and void if the building or work authorized by such permit ia not commenced within
l8o days from the date of such permit orifthe building orworkauth b permit is suspended or abandoned atany time afterthe work is commenced for a period of l8O days (Section 106.4.4 Uniform Building Code).
..APPUCANVS SIGNATURE ,(A,, DATE (0,7,3 ,16
January 09, 2020
CCity of
Carlsbad
BRIDGET & JIM HARPER
1425 YOURELL AVE
CARLSBAD, CA 92008
RE: BUILDING PERMIT EXPIRATION
PERMIT TYPE: BLDG-Residential, Addition
-- -_ - -
PERMIT NUMBER: CBR20184533
ISSUE DATE:, 11/07/2018
ADDRESS: 1425YoureII Ave
Carlsbad, Ca 92008-1052
Our records indicate that your building permit will expire by limitation of time on 03/30/2020.
18.04.030 Section 105.5 amended - pir.ation:
Every permit issued by the Building Official under the provisions of this code shalt expire by
limitation and become null and void if the building or work authorized by such permit is not
commenced within 180 calendar days from the date of such permit, or if the building or' work
authorized by such permit is stopped at any time after the work is commenced for a period of 180
calendar days, or if the, building or work authorized by such permit exceeds three calendar years
from the issuance date of the permit. Work shall be presumed to have commenced if the permittee
has obtained a required inspection approval of work authorized by the permit by the Building
Official within 180 calendar days of the' date of permit issuance Work shall be presumed to be
stopped if the permittee has not obtained a required inspection approval of work by the Building
Official within each 180 day period upon the initial commencement of work authorized by such
permit
Before such work can be recommenced, a new permit shall be obtained to do so, and the fee
therefore shall be one half the amount required for a new permit for such work, and provided that
no changes have been made or will be made in the original plans and specifications for such work,
and provided further that such suspension or abandonment has'not exceeded one year. In order to
renew action on a permit after expiration, the permittee shalt pay a new permit fee.
Any permittee holding an unexpired permit may apply for an extension of time within which work.
may commence under that pe.rmitwhen the permittee is unable to commence work within the time
period required by this section for good and satisfactory reasons.
Please check below indicating your intentions and return this letter to us.
0 Project abandoned. A new permit will be obtained priorto commencing work.
0 Permit 180 day extension request, with written explanation including phone numberand email address.
Request will not beconsidered without explanation
0 Renewal permit requested.
If the project has been completed and only a final inspection, is needed, please call the
inspection request line at (760) 602-2725.
If you have any questions, please contact the Building Inspection Division at 760-602--2700.
Community & Economic Development
Building Division 1 1635 Faraday Avenue, Carlsbad, CA 92008-7314 1 760-602-2700 1 760-602-8560 f I www.carlsbadca.gov
April 16, 2019
city of
Carlsbad
BRIDGET & JIM HARPER
1425 YOURELL AVE
CARLSBAD, CA 92008
PERMIT NUMBER: CBR20181533
ISSUE DATE: 11/07/2018
RE: BUILDING PERMIT EXPIRATION ADDRESS: 1425 Yourell Ave
PERMIT TYPE: BLDG-Residential, Addition Carlsbad, Ca 92008-1052
Our records indicate that your building permit will expire by limitation of time on 06j25/2019-
18.04.030 Section 105.5 amended - Expiration:
Every permit issued by the Building Official under the provisions of this code shall expire by
limitation and become null and void if the building or work authorized by such permit is not
commenced within 180 calendar days from the date of such permit, or if the building or work
authorized by such permit is stopped at any time after the work is commenced for a period of 180
calendar days, or if the building or work authorized by such permit exceeds three calendar years
from the issuance date of the permit. Work shall be presumed to have commenced if the permittee
has obtained a required inspection approval of work authorized by the permit by the. Building
official within 180 calendar days of the date of permit issuance Work shall be presumed to be
stopped if the permittee has not obtained a required inspection approval of work by the Building
official within each 180 day period upon the initial commencement of work authorized by such
permit.
Before such work can be recommenced, a new permit shall be obtained to do so, and the fee
therefore shall be one half theamount required for a new permit for such.work, and provided that
no changes have been made or will be made in the original, plans and specifications for such work,
and provided further that such suspension or abandonment has not exceeded one year. In order to
renew action on a permit after expiration, the permittee shall pay a new permit fee.
Any permittee holding an unexpired permit may apply for an extension of time within which work
may commence under that permitwhen the permittee is unable to commence work within the time
period.required by this section for good and satisfactory reasons.
Please check below indicating your intentions and return this letter to us.
0 Project abandoned. A new permit will be obtained prior to commencing work.
0 Permit 180 day extension request, with written explanation including phone number and email address
Request will not be considered without explanation
0 Renewal permit requested.
If the project has been completed and only a final inspection is needed, please call the
inspection request line at (760) 602-2725.
If you have any questions, please contact the Building Inspection Division at760-602-2700.
Community & Economic Development
Building Division 1 1635 Faraday Avenue, Carlsbad, CA 92008-7314 1 760-602-2700 1 760-602-8560 f I wwwcarlsbadCagov
Permit Type: BLDG-Residential Application Date: 06/27/2018 Owner: COOWNER. BRIDGET & JIM
HARPER
Work Class: Addition Issue Date: 11/07/2018 Subdivision: SHANGRILA TRACT
Status: Closed -Expired Expiration Date: 03/30/2020 Address: 1425 Yourell Ave
Carlsbad, CA 92008
IVR Number: 12181
Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Not ready. Contractor has pick up list. No
BLDG-14 9/16/19, see card for pick up Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
09/24/2019 09/24/2019 BLDG-16 Insulation 105203-2019. Passed Peter Dreibelbis
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
10/02/2019 1610212019 BLDG-82 Drywall, 106156-2019 Passed Tony Alvarado
Exterior Lath, Gas
Test, Hot Mop
Checklist Item COMMENTS Passed
BLDG-17 Interior Lath-Drywall Yes
BLDG-18 Exterior Lath and Yes
Drywall .
BLDG-23 Gas-Test-Repairs . Yes
Complete
Complete
April 23, 2020 Page 20f2
Permit Type: BLDG-Residential Application Date: 06/27/2018 Owner: COOWNER BRIDGET & JIM
HARPER
Work Class: Addition Issue Date: 11/07/2018 Subdivision: SHANGRILA TRACT
Status: Closed - Expired Expiration Date: 03130/2020 Address: 1425 YourelLAve
Carlsbad, CA 92008
IVR Number: 12181
Scheduled
Date
Actual
Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete
11/13/2018 11/13/2018 BLDG-11 075649-2018 Passed Paul Burnette Complete
Foundation/Ftg/Pier
s (Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency . No
BLDG-12 Steel/Bond 075648-2018 Passed Paul Burnette Complete
Beam .
Checklist Item COMMENTS . Passed
BLDG-Building Deficiency No.
12/27/2018 12/27/2018 BLDG-15 080048-2018 Passed Paul Burnette . Complete
Roof/ReRoof (Patio)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency .
No
06/05/2019 06/05/2019 BLDG-13 Shear 093825.2019 Failed Paul Burnette Reinspection Complete
Panels/HD (Ok to
wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency . No
07/17/2019 07/17/2019 BLDG-33 Service 097785-2019 Passed Michael Collins Complete
Change/Upgrade
Checklist Item COMMENTS Passed
BLDG-Building Deficiency EMR called in to Kim. Yes
08/21/2019 08/21/2019 BLDG-13 Shear 101420-2019 Passed Paul Burnetté Complete
• Panels/HD (ok to
wrap)
• Checklist Item COMMENTS Passed
BLDG-Building Deficiency • Yes
BLDG-15 101421-2019 Cancelled Paul Burnette Reinspection Complete
Roof/ReRoof (Patio)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency ' , No
09/10/2019 09/10/2019 BLDG-84 Rough 103611-2019 ,Failed Michael Collins Reinspection Complete
Combo(14,24,34,44)' •
Checklist Item COMMENTS Passed
• BLDG-Building Deficiency Not ready. Contractor has pick up list. No
09/16/2019 09/16/2019 BLDG-84 Rough 104215-2019 Passed Michael Collins' Complete
Combo(14,24,34,44)
April 23, 2020 . ' Page 1 of 2
EsGil
A SAFEbui1tCompany
DATE: AUG. 13, 2018 U APPLICANT
U JURIS.
JURISDICTION: CARLSBAD
PLAN CHECK #.: CBR2018-1533 SET: II
PROJECT ADDRESS: 1425 YOURELL AVENUE
PROJECT NAME: SFR (2-STORY ADDITION & REMODEL) FOR HARPER
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
EsGil staff did not advise the applicant that the plan check has been completed.
EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: ARLEN R9R,1ER
Date contacted,,? (bf )
Mail Telepho e Fax In Person
LII REMARKS:
Telephone #: 760-522-3997
Email: arlenroper(ägmail.com
By: ALl SADRE, S.E. Enclosures:
EsGil
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax(858)560-1576
EsGil
A SAFEbuiIt Company
DATE: JULY 09, 2018
JURISDICTION: CARLSBAD
APPLICANT
JURIS.
PLAN CHECK #.: CBR2018-1533
PROJECT ADDRESS: 1425 YOURELL AVENUE
SET: I
PROJECT NAME: SFR (2-STORY ADDITION & REMODEL) FOR HARPER
El The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
El The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
El The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
El The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
El EsGil staff did not advise the applicant that the plan check has been completed.
EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: ARLEN ROPER
SZ
/ C7 11
Fax In Person
El REMARKS:
Telephone #: 760-522-3997
Email: arlenroper(qmail.com
By: ALT SADRE, S.E. Enclosures:
EsGil
6/28
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576
CARLSBAD CBR2018-1533
JULY 09, 2018
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK#.: CBR2018-1533 JURISDICTION: CARLSBAD
PROJECT ADDRESS: 1425 YOURELL AVENUE
FLOOR AREA: ADDITION = 1,497 STORIES: TWO
REMODEL = 1,503; EXISTING GARAGE = 432 (NO CHANGE)
DECK = 462; PATIO = 151 HEIGHT: 24'
REMARKS:
DATE PLANS RECEIVED BY DATE PLANS RECEIVED BY
JURISDICTION: 6/28 ESGIL CORPORATION: 6/28
DATE INITIAL PLAN REVIEW PLAN REVIEWER: ALl SADRE, S.E.
COMPLETED: JULY 09, 2018
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the California version of
the International Residential Code, International Building Code, Uniform Plumbing Code,
Uniform Mechanical Code, National Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the disabled. This plan review is based on
regulations enforced by the Building Department. You may have other corrections based on
laws and ordinance by the Planning Department, Engineering Department, Fire Department or
other departments. Clearance from those departments may be required prior to the issuance of
a building permit.
Present California law mandates that construction comply with the 2016 edition of the California
Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC,
2015 UPC, 2015 UMC and 2014 NEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2015 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked-up list when you submit the revised plans.
CARLSBAD CBR20 18-1533
JULY 09, 2018
[DO NOT PAY— THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: CARLSBAD PLAN CHECK #.: CBR2018-1533
PREPARED BY: ALl SADRE, S.E. DATE: JULY 09, 2018
BUILDING ADDRESS: 1425 YOURELL AVENUE
BUILDING OCCUPANCY: R3/U; V-B
BUILDING
PORTION
AREA
(Sq. Ft.)
Valuation
Multiplier
Reg.
Mod.
VALUE ($)
LIVING ADD 1497
REMODEL 1503
PATIO 151
DECK 462
Air Conditioning
Fire Sprinklers
TOTAL VALUE 343,993
Jurisdiction Code ICB I
1997 UBC Building Permit Fee V
1997 UBC Plan Check Fee V
Type of Review: i Complete Review 0 Structural Only
C] Repetitive Fee Repeats
O Other
Hourly Hr. @ *
EsGil Fee I $850.591
Comments:
Sheet 1 of 1
CARLSBAD CBR2018-1533
JULY 09, 2018
PLANS
Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of
plans for commercial/industrial projects (THREE sets of plans for residential projects). For
expeditious processing, corrected sets can be submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building
Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans
to EsGil and the Carlsbad Planning, Engineering and Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive,
Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and
calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning,
Engineering and Fire Departments.
NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning,
Engineering and Fire Departments until review by EsGil is complete.
FIRE PROTECTION
2. Please indicate on the plans whether the existing residence has a fire sprinkler
system installed. If so, then provide a note stating that any additions/alterations
will be provided with an automatic residential fire sprinkler system. Sec. R313.2.
3. Clarify two Sheets Al. 1 and add Sheets S6, S7 & S8, on the Sheet Index.
4. Where is the door from BR #1, closet door to exterior, as per Sheet A4. 1, on
floor plans?
STRUCTURAL
5. The City Policy requires a soils report for this project. Please revise the
information on Sheet Si to reflect the soils report info.
6. Specify on structural specifications sheet the soil classification, the soils
expansion index &the design bearing capacity. Sec. 107.2 & 1603.1.6.
7. Note on the foundation plan that "Prior to the contractor requesting a Building
Department foundation inspection, the soils engineer shall advise the building
official in writing that:
The building pad was prepared in accordance with the soils report,
The utility trenches have been properly backfilled and compacted, and
C) The foundation excavations comply with the intent of the soils report."
8. Provide a letter from the soils engineer confirming that the foundation/ grading
plan and specifications have been reviewed and that it has been determined that
the recommendations in the soil report are properly incorporated into the plans.
9. The SW #1, on gridline "D", as per Sheet S3, should be #2, as per calculations.
10. Where is detail 37/S7, as called out on S3, near grid pointF-4?
II. Where is detail 38/S6, as ref. on S3, by grid point 7-E.5?
CARLSBAD CBR2018-1533
JULY 09, 2018
12. Requirements in Seismic Design Category D. 1I?fl1 The structures
assigned to SDC D should satisfy the following requirements, in addition to the
requirements for SDC C: (ASCE 7-10, Sec. 12.3): Show how the irregularities
are addressed on olansicaic's. I.e.. show FB-2. FB-9 are designed for 25% force
increase & supports are adequate for load combinations, per Sec. 12.3.3.4.
Prohibited Horizontal and Vertical Irregularities for Seismic Design Categories D
through F. Structures assigned to Seismic Design Category E or F having horizontal
irregularity Type lb of Table 12.3-1 or vertical irregularities Type ib, 5a, or 5b of Table
12.3-2 shall not be permitted. Structures assigned to Seismic Design Category D having
vertical irregularity Type 5b of Table 12.3-2 shall not be permitted, except when subject to
the limitations of Section 12.3.3.2.
Plan or Vertical Irregularities. For structures having a plan structural irregularity of Type
I a, I b, 2, 3, or 4 of ASCE 7-10, Table 12.3-1 (as shown in Fig. 10.7) or vertical irregularity
Type 4 of Table 12.3-2, the design forces determined from Section 12.8.1 need to be
increased 25 percent for the following connections: 1) diaphragms to vertical elements, 2)
diaphragms to collectors & 3) collectors to vertical elements. (Sec. 12.3.3.4).
Re-entrant corner
a. Torsional irregularity b. Re-entrant corners c. Diaphragm discontinuity
Discontinuity in vertical elements
of lateral-force-resisting system
d. Out-of-plane offsets
Figure 10.7 Examples of Plan Irregularities 1 -4
MISCELLANEOUS
13. To speed up the review process, note on this list where each correction item has
been addressed on plans! caic's. The jurisdiction has contracted with EsGil,
located at 9320 Chesapeake Dr., #208, S.D., CA 92123; Tel: 858/560-1468, to
perform the plan review for your project. If you have any questions regarding
these items, please contact ALl SADRE, S.E. at EsGil. Thank you.
S
W"
Geotechnical Exploration, Inc.
SOIL AND FOUNDATION ENGINEERING Q GROUNDWATER @ ENGINEERING GEOLOGY
IPiwi,iiLIjt
Jim and Bridget Harper
1425 Yourell Avenue
Carlsbad, CA 92008
Subject: Foundation Plan Review
Harper Residence Addition and Deck
1425 You rell Avenue
Carlsbad, California
Job No. 18-11951
RECEIVED
AUG 032018
Dear Mr. and Mrs. Harper: CITY OF CARLSBAD
As requested and as required by the City of Carlsbad reviewer,
the revised foundation structural plans prepared by Simply Strong Engineering, dated July 27, 2018,
for the proposed residence addition and deck, at the subject address. The plans were reviewed from a
geotechnical engineering viewpoint.
After suggested corrections were made, we have found the reviewed structural foundation plans to be
in general accordance with our recommendations presented in our Limited Soil Investigation and Soil
Bearing Value Evaluation, for the subject project, dated July 26, 2018. A copy of the soils report and
this letter shall be provided to the general contractor and pertinent contractors involved with soil
preparation and foundation construction for implementation of our recommendations.
Thank you for the opportunity to be of service. If you have any questions regarding this letter, please
contact our office. Reference to our Job No.18-11951 will help expedite a response to your inquiry.
Respectfully submitted,
GEOTECHNICAL EXPLORATION, INC.
In A.Browning
C.F.G. 26151P.G. 9012
br Projt Geologist
/ONAL
o JONATHAN A. Q 47 BROWNING
No. 261
CERTIFIED •
ENGINEERING
tA GEOLOGIST rV \V1
NOF CAL'."
7420 TRADE STREETO SAN DIEGO, CA. 921210 (858) 549-7222 0 FAX: (858) 549-1604 0 EMAIL: geotechlgei-sd.com
SPIN' Geotechnica-1 Exploration, Inc.
SOIL AND FOUNDATION ENGINEERING 0 GROUNDWATER 0 ENGINEERING GEOLOGY
26 July 2018
Jim and Bridget Harper Job No. 18-11951
1425 Yourell Avenue
Carlsbad, CA 92008
Subject: Limited Soil Investigation and Bearing Value Evaluation
Harper Residence Addition and Deck
1425 Yourell Avenue
Carlsbad, California
Dear Mr. and Mrs. Harper:
In accordance with your request, a representative of Geotechnical Exploration,
Inc. has visited the subject site and performed an evaluation of the soil conditions
in the area of the proposed new one and two story addition in the rear (southwest)
yard of the residence. It is our understanding that the proposed addition and deck
will be founded on new conventional continuous footings and/or new spread
footings with raised wood floors. As part of our investigation, we observed and
evaluated the shallow soil conditions at five locations on the southwest side of the
existing residence.
In addition, we reviewed the foundation plans and calculations to confirm they are
prepared in accordance with the recommendations included in this report. The
structural plans were prepared by Simply Strong Engineering, dated June 8, 2018.
After suggested corrections, we found the plans to be in accordance with our
recommendations.
The field work, conducted on July 18, 2018, consisted of excavating five hand-
auger borings in the area of the proposed addition and deck. The excavations
7420 TRADE STREETO SAN DIEGO, CA. 921210 (858) 549-7222 0 FAX: (858) 549-1604 0 EMAIL: geotech@gei-sd.com
Harper Residence Addition Job No. 18-11951
Carlsbad, California Page 2
revealed that the building site is underlain by approximately 6 inches of loose to
medium dense, silty sand fill/topsoil over medium dense to dense, silty sand
formational materials. The on-site soils are considered to have a very low
expansion potential with an Expansion Index of less than 20.
Based upon our observation of the existing soils, it is our opinion, that the new loads
from the proposed one and two story addition can be founded on new continuous
perimeter and/or spread footings founded into the existing medium dense to dense
formational soils. Any loose surface soils in the proposed building pad areas should
be properly compacted as part of site preparation under any new slab areas. The
new fill shOuld be compacted to at least 90 percent of Maximum Dry Density.
However, the new footings for the addition and deck will be the only excavation for
the project.
It is our opinion that the existing medium dense to dense formational soils
will provide adequate bearing strength for the proposed new one and two
story loads. New footings have been designed for an allowable soil bearing
capacity of 2,000 pounds per square foot (psf) founded in the existing
formational soils. We do recommend that the new footings and slabs contain
at least a nominal amount of reinforcing steel to reduce the separation of
cracks should they occur. The static allowable soil bearing capacity may be
increased one-third for structural design including seismic or wind loads.
New footings should have a minimum depth of 18 inches and a width of at
least 15 inches, founded in the medium dense to dense formational soils. A
minimum of steel for continuous footings should include at least four No. 4
bars continuous, with two bars 3 inches from the bottom of the footing.
Harper Residence Addition Job No. 18-11951
Carlsbad, California Page 3
Site-specific seismic design criteria to calculate the base shear needed for the
design of the residential addition are presented in the following table. The
design criteria was obtained from the California Building Code (CBC) 2016
edition, and is based on the distance to the closest active fault and soil
profile classification.
The proposed additions should be designed in accordance with Section 1613
of the 2016 CBC, which incorporates by reference the ASCE 7-10 for seismic
design and the following parameters should be utilized. We have determined
the mapped spectral acceleration values for the site based on a latitude of
33.1733 degrees and longitude of 117.3418 degrees, utilizing a program
titled "Design Maps and Tools," provided by the USGS, which provides a
solution for ASCE 7-10 (Section 1613 of the 2016 CBC) utilizing digitized files
for the Spectral Acceleration maps.
In addition, we have assigned a Site Classification of D. The response
parameters for design are presented in the following table. The design
spectrum acceleration vs. Period T is attached.
TABLE I
Mapped Spectral Acceleration Values and Design Parameters
Ss Is, I Fa I Fv I Sms Smi I SdS I Sd1
1.131g I 0.434g 11.048 11.566 1 1.185g I 0.680g 10.7909 1 0.453g
The liquefaction of saturated sands during earthquakes can be a major cause
of damage to buildings. Liquefaction is the process by which soils are
transformed into a viscous fluid that will flow as a liquid when unconfined. It
.1 •
Harper Residence Addition Job No. 18-11951
Carlsbad, California Page 4
occurs primarily in loose, saturated sands and silts when they are sufficiently
shaken by an earthquake.
On this site, the risk of liquefaction of foundation materials due to seismic
shaking is considered to be remote due to the relatively shallow, medium
dense to dense nature of the natural-ground material and the lack of a
shallow static groundwater surface under the site. No soil liquefaction or soil
strength loss is anticipated to occur due to a seismic event.
Any new concrete slabs on-grade (on properly compacted fill or dense
formational soils) should be a minimum of 4 inches actual thickness and be
reinforced with at least No. 3 steel bars on 18-inch centers, in both
directions, placed at mid-height in the slab. The interior slab should be
underlain by a 15-mil vapor barrier (15-mil StegoWrap) placed directly on
properly compacted subgrade. The sand base may be waived.
We recommend that isolation joints and sawcuts be incorporated to at least
one-fourth the thickness of the slab in any slab designs. The joints and cuts,
if properly placed, should reduce the potential for and help control floor slab
cracking. In no case, however, should control joints be spaced farther than
20 feet apart, or the width of the slab. Control joints should be placed within
12 hours after concrete placement as soon as concrete sets and no raveling
of aggregate occurs.
The active earth pressure (to be utilized in the design of cantilever, non-
restrained walls) should be based on an Equivalent Fluid Weight of 38 pounds
per cubic foot (pcf) for level backfill only and 52 pcf for sloping backfill if on-
site soils are used. Additional loads applied within the potential failure block
;1.
Harper Residence Addition Job No. 18-11951
Carlsbad, California Page 5
should be added to the active soil earth pressure by multiplying the vertical
surcharge load by a 0.37 lateral earth pressure coefficient.
For restrained wall conditions, we recommend an equivalent fluid weight of
56 pcf. Surcharge loads may be converted to lateral pressures by
multiplying by a factor of 0.47. Should seismic soil increment be required,
the unrestrained walls with level backfill should be designed for a triangular
pressure of 14 pcf, in addition to the regular static loading, with zero
pressure at the top and the maximum pressure at the bottom of the wall.
The passive earth pressure of the encountered formational soils (to be used
for design of shallow foundations and footings to resist the lateral forces)
should be based on an Equivalent Fluid Weight of 275 pcf. This passive earth
pressure should only be considered valid for design if the ground adjacent to
the foundation structure is essentially level for a distance of at least three
times the total depth of the foundation and is properly compacted or dense
natural soil. An allowable Coefficient of Friction of 0.40 times the dead load
may be used between the bearing soils and concrete foundations, walls or
floor slabs.
Adequate measures should be taken to properly finish-grade the site after
the new addition and other improvements are in place. Drainage waters
from this site and adjacent properties are to be directed away from perimeter
foundations, floor slabs, and footings, onto the natural drainage direction for
this area or into properly designed and approved drainage facilities. Proper
subsurface and surface drainage will help minimize the potential for waters to
seek the level of the bearing soils under the foundations, footings, and floor
slabs. Failure to observe this recommendation could result in undermining,
Harper Residence Addition Job No. 18-11951
Carlsbad, California Page 6
differential settlement of the building foundation or other improvements on
the site, or moisture-related problems.
It is not within the scope of our services to provide quality control oversight
for surface or subsurface drainage construction or retaining wall sealing and
base of wall drain construction. It is the responsibility of the contractor
and/or their retained construction inspection service provider to provide
proper surface and subsurface drainage.
Due to the possible build-up of groundwater (derived primarily from rainfall
and irrigation), excess moisture is a common problem in below-grade
structures or behind retaining walls that may be planned. These problems
are generally in the form of water seepage through walls, mineral staining,
mildew growth and high humidity. In order to minimize the potential for
moisture-related problems to develop, proper cross ventilation and water-
proofing must be provided for below-ground areas, in crawl spaces, and the
backfill side of all structure retaining walls must be adequately waterproofed
and drained.
Proper subdrains and free-draining backwall material (such as gravel or
geocomposite drains such as Miradrain 6000 or equivalent) should be
installed behind all retaining walls on the subject project in addition to wall
waterproofing. Geotechnical Exploration, Inc. will assume no liability for
damage to structures that is attributable to poor drainage.
Planter areas and planter boxes should be sloped to drain away from the
foundations, footings, and floor slabs. Planter boxes should be constructed
with a closed bottom and a subsurface drain, installed in gravel, with the
, ,-
.I
Harper Residence Addition Job No. 18-11951
Carlsbad, California Page 7
direction of subsurface and surface flow away from the foundations, footings,
and floor slabs, to an adequate drainage facility. The finish grade around the
addition should drain away from the perimeter walls to help reduce or
prevent water accumulation.
Exterior slabs or rigid improvements should also be built on properly
compacted soils and be provided with concrete shrinkage reinforcement and
adequately spaced joints.
Geotechnical Exploration, Inc. recommends that we be asked to verify the
actual soil conditions revealed in footing excavations prior to form and steel
reinforcement placement.
Should you have any questions regarding this matter, please contact our office.
Reference to our Job No. 18-11951 will help to expedite a response to your
inquiries.
Respectfully submitted,
37.
Heiser EXPLORATION, INC.
-4PE!Ame A. =Cerro's.
Senior Project Geologist R.C.E. 34422/G.E. 2007
Senior Geotechnical Engineer
N.
( GE 002007 *\EXP 5/3 //7J
rA
CAL
Sn Marcos
Escondido'
U ZIJSGS Design Maps Summary Report
User-Specified Input
Report Title 1425 Yourell Avenue, Carlsbad, CA
Wed July 25, 2018 21:49:41 UTC
Building Code Reference Document ASCE 7-10 Standard
(which utilizes USGS hazard data available in 2008)
Site Coordinates 33.17330N, 117.3418°W
Site Soil Classification Site Class D - "Stiff Soil"
Risk Category 1/11/111
A
- - C
fl
-
f , t4kMI1l
4'
Vista Oceanside \\4 ;
1sbad
11cUeIic
P I Siur Au1ci
USGS-Provided Output
S = 1.131 g 5MS = 1.185 g 5DS = 0.790 g
S1 = 0.434 g SMS = 0.680 g S01 = 0.453 9
For information on how the SS and Si values above have been calculated from probabilistic (risk-targeted) and
deterministic ground motions in the direction of maximum horizontal response, please return to the application and
select the "2009 NEHRP" building code reference document.
NICE Response Spectrum Design Response Spectrum
Pcrlod, T istc, IkrIwI. I 4sv)
For PGA,, TL, C, and CR1 values, please view the detailed repgj.
Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the
accuracy of the data contained therein. This tool is not a substitute for technical subject-matter knowledge.
OWNER'S CERTIFICATE:
I UNDERSTAND AND ACKNOWLEDGE THAT I MUST: (1) IMPLEMENT
BEST MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION
ACTIVITIES TO THE MAXJMUM EXTENT PRACTICABLE TO AVOID
THE MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO
AVOID THE EXPOSURE OF STORM WATER TO CONSTRUC110N
RELATED POLLUTANTS; AND (2) ADHERE TO, AND AT ALL TIMES,
COMPLY NTH THIS CITY APPROVED TIER 1 CONSTRUCTION SWPPP
THROUGHOUT THE DURATION OF THE CONSTRUCTION AC11V111E5
UNTIL THE CONSTRUCTION WORK IS COMPLETE AND APPROVED
DATE
STORM WATER COMPLIANCE FORM
TIER I CONSTRUCTION SWPPP 2;c- 1l3T3
BEST MANAGEMENT PRACTICES (BMP) SELECTION TABLE
Erosion Control Sediment Control BMPs Tracking Non-Storm Water Waste Management and Materials
BMPs Control BMPs Management BMPs Pollution Control BMPs
.2 .2 —
- •
-
- U, E .
.2
.
Best Management Practice* k 0' £ E ()CD
rn
-
(BMP) Description — - .' , UJ 2 E a) C CD E 0 0 a, Lo -ga)
- 0 - a) - - E - 0 a) 0 0)0 '- 0 - ._ 2 a) a) _ o
0-
-'-' -
0'
-v 0 ,. 0'
0 0 0'
Q 0
o Q)
0 0 t _ 2 -.-- = 0 a) -C 0 0 -.- 0
1. - 0 .-' . 0 0 0 0 -- -- o 0 .. > 0 C 0 - a) --' 0 0 -- 0 0 -- = 0 = 0 0 NJ 0 0 C C 0 0
C) 0 I-. Lii C Cl) Cl) Cl) L) Li C) (n :> Cl) C/) 0- U) £ (/) C (L O 0 0- > C) (1) Cl) (I) C) (I) M M M C)
CASQA Designation — r- 00 0) n * Lo to N- CO C'-J ) N- CO T 04 ? i ?
W UJ LLLLIJL'J CI)V)C/,V)
Construction Activity I-i-i Lii LU Lii (/) Cl) C/) C/) C/) (/) C/) C/) I
Grading/SoilDisturbance
- Trenching/Excavation — — — -- — — — — — — — —
- Stockpiling — —. — — — — — — — — — —
— Drilling/Boring — — — —
--
-- — — — — — —
- Concrete/AsphaltSawcutting — —
--
— — -- — — — — — — —
Concrete Flatwork
- Paving — — -- — — — — — — — — — —
- Conduit/PipeInstallation — — — — — — — — — — — — —
Stucco/MortarWork — —
--
--
-- — — — — — — — — —
Waste Disposal
- Staging/Lay Down Area — — ---- — — — — — — — — —
— Equipment Maintenance and Fueling — — — —
--
--
--
— — — — — — — —
Substance Use/Storage _Hazardous
--
- Dewatering — —
--
— —
--
— — — — — — — —
SiteAccessAcrossDirt
-- --
- Other(list): — — — — — -- — — — — — — - —
Instructions:
Check the box to the left of all applicable construction activity (first column) expected to occur during construction.
Located along the top of the BMP Table is a list of BMP's with it's corresponding California Stormwater Quality Association (CASQA) designation number. Choose one
or more BMPs you intend to use during construction from the list. Check the box where the chosen activity row intersects with the BMP column.
Refer to the CASQA construction handbook for information and details of the chosen BMPs and how to apply them to the project.
PROJECT INFORMATION
Site Address:/ /(
Assessor's Parcel Number:
Emergen ,,/1
Na e
24 Hour Phone:Q_
Construction Threat to Storm Water Quality
(Check Box)
E MEDIUM El LOW
STORM WATER POLLUTION PREVENTION NOTES
ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE
AVAILABLE ON SITE TO FACILITATE RAPID INSTALLATION
OF EROSION AND SEDIMENT CONTROL BMPs WHEN RAIN
IS EMINENT.
THE OWNER/CONTRACTOR SHALL RESTORE ALL EROSION
CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION
OF THE CITY INSPECTOR AFTER EACH RUN—OFF PRODUCING
RAINFALL.
THE OWNER/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION
CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY
INSPECTOR DUE TO INCOMPLETE GRADING OPERATIONS OR
UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE.
ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE
AT THE END OF EACH WORKING DAY WHEN THE FIVE (5)
DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PECENT
(40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER
EACH RAINFALL.
ALL GRAVEL BAGS SHALL CONTAIN 3/4 INCH MINIMUM
AGGREGATE.
ADEQUATE EROSION AND SEDIMENT CONTROL AND PERIMETER
PROTECTiON BEST MANAGEMENT PRACTICE MEASURES MUST
BE INSTALLED AND MAINTAINED.
THE CITY INSPECTOR SHALL HAVE THE AUTHORITY TO ALTER
THIS PLAN DURING OR BEFORE CONSTRUCTION AS NEEDED
TO ENSURE COMPLIANCE WITH CITY STORM WATER QUALITY
REGULATIONS.
E-29 Page 1 of 1 REV 11/17
(fty of
Carlsbad
CERTIFICATION DFSCHOOL FEES PAID -
This form must be completed by the City, the applicant,ad hea ropaeschooI districts and returned to the City prior
to issuing a building permit. The City will not issue any'bujlding .r)ij j]Jjiut a completed school fee form.
Project No. & Name: OCT 03 2018
C CARLSBAD
Plan Check No.: CBR2018-1533 i . - fliVI.'I1)N
Project Address: 1425 YOURELL AVE
Assessor's Parcel No.: 1560525100
Project Applicant: COOWNER BRIDGET & JIM HARPER
(Owner Name)
Residential Square Feet:
New/Additions: 1,497
Second Dwelling Unit:
Commercial Square Feet:
New/Additions:
City Certification: City of Carlsbad Building Division Date: 06/27/2018
Certification of Applicant/Owners. The person executing this declaration ("Owner") certifies
under penalty of perjury that (1) the information provided above is correct and true to the
best of the Owner's knowledge, and that the Owner will file an amended certification of
payment and pay the additional fee if Owner requests an increase in the number of
dwelling units or square footage after the building permit is issued or if the initial
determination of units or square footage is found to be incorrect, and that (2) the Owner is
the owner/developer of the above described project(s), or that the person executing this
declaration is authorized to sign on behalf of the Owner.
Carlsbad Unified School District
6225 El Camino Real
Carlsbad CA 92009
Phone: (760) 331-5000
EJ Encinitas Union School District
101 South Rancho Santa Fe Rd
Encinitas, CA 92024
Phone: (760) 944-4300 xli 66
LLJ San Dieguito Union H.S. District
684 Requeza Dr.
Encinitas, CA 92024
Phone: (760) 753-6491 Ext 5514
(By Appt. Only)
L 71 San Marcos Unified Sch District
255 Pico Ave Ste. 100
San Marcos, CA 92069
Phone: (760) 290-2649
Contact: Katherine Marcelja
- (By Appt.only)
Vista Unified School District
1234 Arcadia Drive
Vista CA 92083
Phone: (760) 726-2170 x2222
SCHOOL DISTRICT SCHOOL FEE CERTIFICATION
(To be completed by the school district(s))
THIS FORM INDICATES THAT THE SCHOOL DISTRICT REQUIREMENTS
FOR THE PROJECT HAVE BEEN OR WILL BE SATISFIED.
The undersigned, being duly authorized by the applicable School District, certifies that the developer, builder,
or owner has satisfied the obligation for school facilities. This is to certify that the applicant listed on page 1
has paid all amounts or completed other applicable school mitigation determined by the School District. The
City may issue building permits for this project.
Signature of Authorized School District Officials
(q &V\
Title: Date:
Name of School District CARLSBAD UNIFIED SCHOOL DISTRICT
5220 EL CAMINO REAL
CARLSBAD, CA 92009
Building Division
1635 Faraday Avenue I Carlsbad, CA 92008 760-602-2719 I 760-602-8558 fax building@carlsbadca.gov
INSTALLATION CERTIFICATE (Page 12 of 12) CF-6R
Site Address
/'f7h oure// i4ve. C411416d' 64, '1Zoo
Permit Number
County Subdivision Lot Number
Description of Insulation (Formerly IC-1 Form)
RAISED FLOOR
Material c1'4I64 9 44
Thickness (inches) Coy 1'
SLAB FLOORJPERIMETER
Material
Thickness (inches)
Perimeter Insulation Depth (inches)
EXTERIOR WALL
Brand Name
Thermal Resistance (R-Value) it 19
Brand Name
Tlermal Resistance (R-Value)
Frame Type 'l((o WCJOC?,
Cavity Insulation
Material '(1 MID, 6c
Thickness (inches) Co
Exterior Foam Sheathing
Material
Thickness (inches)
Brand Name A(i
Thermal Resistance (R-Value) RI Cl
Brand Name
Thermal Resistance (R-Value)
4 FOUNDATION WALL
Material Brand Name
Thickness (inches) Thermal Resistance (R-Value)
CEILING
Batt or Blanket Type .Qo4-15 Brand Name (.c . A
Thickness (inches) (ps Thermal Resistance (R-Value) ThCl
Loose Fill Type - Brand
Contractor's min installed weight/ft' lb Minimum thickness inches
Manufacturer's installed weight per square foot to achieve Thermal Resistance (R-Value)
ROOF
Material 1oer _______________
Thickness (inches) I &'
Declaration
Brand Name C.'+ouyi_"Sd
Thermal Resistance (R-Value) '23 p
V 0 I hereby certify that the above insulation was installed in the building at the above location in conformance with the
current Energy Efficiency Standards for residential buildings (Title 24, Part 6, California Code of Regulations) as indicated
on the Certificate of Compliance, where applicable.
Item gs
(if applicable)
Signature Date Installing Subcontractor (Co. Name) OR
General Contractor (Co. Name) OR Owner
OR Window Distributor
CA I (_Tt44Uf+.'o,_
Item #s / Signat._— Date Installing Subcontractor (Co. Name) OR
(if applicable) General Contractor (Co. Name) OR Owner
OR Window Distributor
Item #s Signature Date Installing Subcoiitractor (Co. Name) OR
(if applicable) General Contractor (Co. Name) OR Owner
OR Window Distributor
Residential Compliance Forms April 2005