Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2810 CARIBOU CT; 110; CBC2020-0221; Permit
bty of Building Permit Finaled Carlsbad Commercial Permit Print Date: 12/07/2020 Permit No: CBC2020-0221 Job Address: 2810 CARIBOU CT, # 110, CARLSBAD, CA 92010 Status: Closed - Finaled Permit Type: BLDG-Commercial Work Class: Tenant Improvement Parcel #: 2091200300 Track #: Applied: 06/16/2020 Valuation: $251,758.63 Lot #: Issued: 08/07/2020 Occupancy Group: Project #: Finaled Close Out: #of Dwelling Units: Plan #: Bedrooms: construction Type: Bathrooms: Orig. Plan Check #: Inspector: PBurn Plan Check #: Final Inspection: 12/07/2020 Project Title: Description: ZENSE: 5,413 SF SHELL TO OFFICE Applicant: Property Owner: ZENSE-LIFE INC VICTORY CARLSBAD OAKS INNOVATION LEIF BOWMAN CENTER LP 2810 CARIBOU CT, # 100 1261 PROSPECT ST. #9 CARLSBAD, CA 92010 LA JOLLA, CA 92037 (858) 888-5289 Contractor: - S P WHITE CONSTRUCTION INC 2524 GATEWAY RD CARLSBAD, CA 92009-1742 (760) 931-1130 FEE AMOUNT BUILDING PERMIT FEE ($2000+) $1,165.60 BUILDING PLAN CHECK FEE (BLDG) $815.92 ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL $89.00 FIRE S Occupancies < 50,000sq. ft. TI $373.00 GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION $175.00 MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL $55.00 PUBLIC FACILITIES FEES - inside CFD $4,582.01 5B1473 GREEN BUILDING STATE STANDARDS FEE $11.00 STRONG MOTION-COMMERCIAL $70.49 TRAFFIC IMPACT Commercial-Industrial w/in CFD $10,449.00 Total Fees: $17,786.02 . Total Payments To Date: $17,786.02 Balance Due: $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building. Division . Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-2700 1 760-602-8560 f I www.carlsbadca.gov COMMERCIAL BUILDING PERMIT APPLICATION B-2 Job Address 2810 Caribou Court, Carlsbad, CA 92010 Suite: 110 (City o f Carlsbad /?fl Plan Check l(O2ZI Est. Value 2'3t)'-PEQ3_ PC Deposit Date 06.15.2020 APN: 209-120-03-00 CT/Project#: Lot #: Fire Sprinklers: ® YES O NO Air Conditioning: ® YES O NO Electrical Panel Upgrade: 0 YES ® NO BRIEF DESCRIPTION OF WORK: Office T.I. Scope includes adding open office, restrooms, shower, conference rooms and work room to warm shell. 413 '5 ki1 o OcECf E Addition/New: Living SF, Deck SF, Patio SF, Garage SF Is this to create an Accessory Dwelling Unit? 0 Y ON New Fireplace? 0 Y Q N, if yes how many? fl Remodel: SF of affected area Is the area a conversion or change of use ? 0 Y 0 N Pool/Spa: SF Additional Gas or Electrical Features? OSolar: KW, _____ Modules, Mounted:ORoof OGround, lilt:O VON, RMA:OYON, Battery:OY ON, Panel Upgrade: Ov ON El Reroof: E Plumbing/Mechanical/Electrical Only: D Other: APPLICANT (PRIMARY CONTACT) PROPERTY OWNER Name: Leif Bowman Name: Casey Gilley - Victory Carlsbad Oaks Address: 2810 Caribou Court, Suite 110 Address: 1261 Prospect St., Suite 9 City: Carlsbad State:_CA Zip: 92010 City: La Jolla State: _CA Zip: 92008 Phone: 858.888.5289 Phone: 888.815-8886 Email: Ibowman@zense-life.com Email: casey@badieedevelopment.com DESIGN PROFESSIONAL CONTRACTOR BUSINESS Name: Trevor Wells Name: White Construction - Travis Sham Address: 3911 Sorrento Valley Blvd., Suite 120 Address: 2524 Gateway Rd. City: San Diego State: CA Zip: 92121 City: Carlsbad State: CA Zip: 92009 Phone: 619.564.3696 Phone: 760.802.9707 Email: twells@waremalcomb.com Email: travis@whiteconstructioninc.com Architect State License: C30270 State License: 1023856 Bus. License:BLNR000431022017 (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law {Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: BuildingcarIsbadca.gov B-I Page 1 of 2 Rev. 06/18 (OPTION A): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. IZI I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Company Name:State Conensaon Ifli Fund Policy No. 30-20 Expiration Date: 111f2021 11 Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to be come subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. CONTRACTOR SIGNATURE: DAGENT DATE: siisoo (OPTION B ): OWNER-BUILDER DECLARATION: I hereby affirm that lam exempt from Contractor's License Law for the following reason: J I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). J I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). Eliarn exempt under Section Business and Professions Code for this reason: I personally plan to provide the major labor and materials for construction of the proposed property improvement. OYES 0 NO I (have / have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address/ phone / contractors' license number): I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work): OWNER SIGNATURE: DAGENT DATE: CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: Lender's Address: ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). APPLICANT SIGNATURE: ~tLUA DATE: .06.15.20m 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carIsbadCa.gov B-i Page 2 of 2 Rev. 06/18 Permit Type: BLDG-Commercial . . Application Date: 06/16/2020 Owner: VICTORY CARLSBAD OAKS INNOVATION CENTER LP Work Class: Tenant Improvement • Issue Date: 08/07/2020 Subdivision: Status: Closed - Finaled Expiration Date: 05/10/2021 . Address: 2810 CARIBOU CT, #110 CARLSBAD, CA 92010 IVR Number: 26933 Scheduled Actual. Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date . Status Checklist Item COMMENTS Passed BLDG-Building Deficiency . Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final . Yes BLDG-Structural Final . . . Yes BLDG-Electrical Final . Yes ( Monday, December 7, 2020 Page 3 of 3 Permit Type: BLDG-Commercial Application Date: 06/16/2020 Owner: VICTORY CARLSBAD OAKS INNOVATION CENTER LP Work Class: Tenant Improvement Issue Date: 08/07/2020 Subdivision: Status: Closed - Finaled Expiration Date: 05/10/2021 Address: 2810 CARIBOU CT, #110 CARLSBAD, CA 92010 IVR Number: 26933 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 9I3012020 09/30/2020 BLDG-84 Rough 139703-2020 Partial Pass Tim Kersch Reinspection Incomplete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 No Rough-Ducts-Dampers 10/06/2020 10/06/2020 BLDG-14 . - 140214-2020 Passed . Paul Burnette . Complete Frame/Steel/Bolting/We Idling (Decks) . Checklist Item COMMENTS Passed BLDG-Building Deficiency . . . Yes 11/09/2020: 11/09/2020 'BLDG-85 T-Bar, Ceiling .143401-2020 Passed Tim Kersch ' Complete '. Grids, Overhead Checklist Item . COMMENTS . . Passed BLDG-Building Deficiency . Yes BLDG-14 . . Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout. . No BLbG-34 Rough Electrical . . . Yes BLDG-44 Yes Rough-Ducts-Dampers 12/03/2020 12/03/2020 BLDG-Final Inspection 145285-2020 Partial Pass Paul Burnette Reinspection Incomplete Checklist Item COMMENTS . . Passed BLDG-Building Deficiency . Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final . Yes BLDG-Electrical Final . . Yes 12104/2020- 12/04/2020 BLDG-Fire Final 145498.2020 Passed Felix Salcedo .. Complete Checklist Item COMMENTS Passed FIRE- Building Final Yes 12/07/2020 12/07/2020 BLDG-Final Inspection 145507-2020 Passed Tim Kersch. . Complete Monday, December 7, 2020 . Page 2 of 3 Building Permit Inspection History Finaled city of Carlsbad Permit Type: BLDG-Commercial Application Date: 06/16/2020 Owner: VICTORY CARLSBAD OAKS INNOVATION CENTER LP Work Class: Tenant Improvement Issue Date: 08/07/2020 Subdivision: Status: Closed - Finaled Expiration Date: 05/10/2021 Address: 2810 CARIBOU CT, #110 IVR Number: 26933 CARLSBAD, CA 92010 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 0812412020 08/2412020 BLDG-21 136460-2020 Passed Paul Burnette Complete UndergroundlUnderflo or Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-31 136461-2020 Passed Paul Burnette Complete Underground/Conduit - Wiring Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 09/09/2020 09/09/2020 BLDG-14 137868-2020 Partial Pass Paul Burnette Reinspection Incomplete Frame/Steel/Bolting/We Iding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 09I17/2020 09/17/2020 BLDG-14 138547-2020 Partial Pass Paul Burnette Reinspection Incomplete Frame/Steel/Bolting/We Iding (Decks) Checklist Item COMMENTS Passed BLDG-Building peficiency Yes BLDG-34 Rough 138548.2020 Partial Pass Paul Burnette Reinspection Incomplete Electrical Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 09/24/2020 09/24/2020 BLDG-84 Rough 139207-2020 Failed Paul Burnette Reinspection Incomplete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-14 No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers Monday, December 7, 2020 Page 1 of 3 DATE: 7/31/2020 JURISDICTION: Carlsbad V EsGil A SAFEbulif Company /APPLICANT Jt PLAN CHECK #.: CBC2020-0221 SET: II PROJECT ADDRESS: 2810 Caribou Court PROJECT NAME: Zense Life: Office T.I. LI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. LI The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. LI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Leif Bowman EsGil staff did not advise the applicant that the plan check has been completed. L1 EsGil staff did advise the applicant that the plan check has been completed.- Person contacted: Leif Bowman Date contacted :g I3/20 (bj/)) Telephone #: 858-888-5289 Email: lbowman@zense-life.com Telephone Fax In Person AMARKS: Page A23 storage under stairs required to be / V'approved automatic fire sprinkler per 413.2 exception. By: Steven Miller Enclosures: EsGil 7/31 hour fire rated or provided with a 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGV. il A SAFEbuiLt'Company DATE: 6/29/2020 JURISDICTION: Carlsbad U APPLICANT U JURIS. PLAN CHECK #.: CBC2020-0221 PROJECT PROJECT NAME: Zense Life: Office T.I. SET:I EJ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. Ej The applicant's copy of the check list has been sent to: Leif Bowman EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Leif Bowman Telephone #: 858-888-5289 Date contacted: Mail Telephone E REMARKS: By: Steven Miller EsGil (by: ) Email: lbowman@zense-life.com Fax In Person Enclosures: 6/29/2020 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 PLAN REVIEW CORRECTION LIST COMMERCIAL PLAN CHECK #.: CBC2020-0221 JURISDICTION: Carlsbad• OCCUPANCY: B,S1 USE: TYPE OF CONSTRUCTION: IlIB ACTUAL AREA: 5413 ALLOWABLE FLOOR AREA: STORIES: 1 HEIGHT: SPRINKLERS?: Yes OCCUPANT LOAD: 83 DATE PLANS RECEIVED BY JURISDICTION: 6/15/2020 DATE INITIAL PLAN REVIEW COMPLETED: 6/29/2020 FOREWORD (PLEASE READ): DATE PLANS RECEIVED BY ESGIL CORPORATION: 6/18/2020 PLAN REVIEWER: Steven Miller This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2019 CBC, which adopts the 2018 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2018 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. GENERAL Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. PLANS 2. Provide a Building Code Data Legend on the Title Sheet. Include the following code information for each building proposed: Occupancy Classification(s) For Mixed Occupancy Buildings, state whether the "non separated" or "separated" option was chosen from Sections 508.3/508.4. Description of Use Type of Construction Sprinklers: Yes or No Stories Height Floor Area Occupant Load Place on the cover sheet INTERIOR WALL AND CEILING FINISHES Provide a note on the plans or on the finish schedule, stating, "Wall and ceiling materials shall not exceed the flame spread classifications in IBC Table 803.13." FIRE EXTINGUISHING Specify on the plans that portable fire extinguishers will be installed in the building in accordance with Section 906. PLUMBING & MECHANICAL Please show the location of the drinking fountain within the plumbing plans. Make sure a waste, vent and water supply design are shown. Make sure it is shown within the fixture schedule. Please the following note on the plans: "Per CPC 906.1, ABS/PVC vent terminations up through the roof exposed to sunlight are required to be protected by water based synthetic latex paints." Please show compliance with CIVIC 603.4.1 & 603.5 for length limitations for factory made flexible air ducts: (1) Cannot be greater than 5' in length, (2) cannot be used as a replacement of rigid elbows (i.e. only an elbow connect to a terminal device/ register is acceptable), (3) sag between supports hangers shall not exceed %" per foot of support spacing, and (4) the elbow connection to the terminal device/ register is required to have a bend radius size no less than one duct diameter. All mechanical ventilated units are required to have at minimum a MERV-13 filter within the outside air/return air duct. Please address. CIVIC 401.2 Clearly specify within the mechanical plans that a duct leakage test will be conducted that complies with CIVIC 603.10.1 The exhaust routing between the mechanical floor plan on sheet M1.0 and the mechanical roof plan on sheet M2.0 are inconsistent. Please correct sheet M1.0 to show the proper duct routing. NOTE: 10' clearance is required from all forced air inlets as specified on sheet M2.0. Please show the required 42 inches tall "Guards" (guard rails) or building parapets height where appliances, mechanical equipment, fans, roof hatch openings or other components that require service are located within 10 feet of a roof edge or open side of a walking surface. CBC 1015.6 & 1015.7 MISCELLANEOUS LIFE/SAFETY Per California law, additions or alternations of Commercial projects or Multifamily Residential projects (condos, apartments and hotels with kitchens) available for use before January 1, 1994 may require replacement of noncompliant plumbing fixtures *** by water conserving fixtures: All plumbing fixtures in the building where an addition will increase the floor area of the building by 10%. (Or) Plumbing fixtures that serve the alternations or improvement in which the building permit valuation exceeds $150,000.00. (Or) An alternation or improvement to a room containing noncompliant fixtures (regardless of valuation). Please note on the plans the specific plumbing fixtures requiring replacement. "Noncompliant plumbing fixtures" are any of the following: Any water closet exceeding 1.6 gallons/flush. Any urinal manufactured to use more than 1.0 gallon/flush. Any showerhead exceeding 2.5 gallon/minute. Any interior faucet that emits more than a 2.2 gallons/minute. 13. Please provide notes on the plans to show the suspended ceilings in Seismic Design Categories D, E & F comply with ASCE 7-16 Section 13.5.6.2.2 as follows: The width of the perimeter supporting closure angle or channel shall be not less than 2.0 in. unless qualified perimeter supporting clips are used. Closure angles or channels shall be screwed or otherwise positively attached to wall studs or other supporting structures. Perimeter supporting clips shall be qualified in accordance with approved test criteria per Section 13.2.5. C. Perimeter supporting clips shall be attached to supporting closure angle or channel with a minimum of two screws per clip and shall be installed around the entire ceiling perimeter. In each orthogonal horizontal direction, one end of the ceiling grid shall be attached to the closure angle, channel, or perimeter supporting clip. The other end of the ceiling gird in each horizontal direction shall have a minimum 0.75-in clearance from the wall and shall rest upon and be free to slide on a closure angle, channel, or perimeter supporting clip. Ceiling areas over 2500 ft.2 must have seismic separation joints or full height partitions. Ceilings without rigid bracing must have 2" oversize trim rings for sprinklers and other ceiling penetrations. NON-RESIDENTIAL GREEN BUILDING STANDARDS The California Building Standards Commission has adopted the Green Building Standards Code and must be enforced by the local building official. The following mandatory requirements for commercial construction must be included on your plans. The following Green Building Standards apply to newly constructed buildings, along with nonresidential additions of 1,000 sq. ft. or larger or alterations (tenant imDrovements) with a value of $200,000 or more. CGC 101.3. Provide a sheet on the plans labeled "Green Building Code Requirements" and include the following notes as applicable. 14. Electric Vehicle Charging: If the newly constructed building includes a parking design of 10 or more spaces compliance with Table 5.106.5.3.3 is necessary for EV future charging capability. Provide the following design requirements found in section 5.106.5.3: Number of future EV spaces required, installed raceway design, electrical capability (amperes and location) and signage. a) Be sure to also comply with Title 24 disabled access requirements for the EV stalls. Section 11 B-228.3. 15. If electrical vehicle charging equipment is installed: Provide a complete electrical design, including equipment specifications, a site plan, and an electrical branch circuit design, including load calculations. Include the compliance design for the accessibility requirements found in CBC 11 B-228.3 and CBC 11 B-812.5. Storm water pollution prevention. Note on the site plan that for projects which disturb less than one acre of land and are not part of a larger common plan of development or sale shall prevent the pollution of storm water runoff from the construction activities through one or more of the following measures (Section 5.106.1): a) Storm water pollution prevention. (One acre or more) Compliance with NPDES is required. See the CGC 5.106.2 for compliance requirements. Bicycle parking. Short term and Long Term: Note on the plans that bicycle parking for projects shall comply with CGC Section 5.106.4. The specific details must be submitted and approved by the Planning Department. Low-emitting, fuel-efficient and carpool/van pool parking. Note on the plans that fuel-efficient vehicle parking will be provided in accordance with CGC Section 5.106.5.2. The specific details for the parking must be submitted and approved by Planning Department. Light pollution reduction. Note on the plans that exterior light pollution must comply with CGC section 5.106.8. Grading and paving. Note on the plans that the site grading or a drainage system will manage all surface water flows to keep water from entering buildings. CGC Section 5.106.10. Moisture control. Note on the plans that landscape irrigation systems shall be designed to prevent spray on structures. Exterior entries subject to foot traffic or wind-driven rain shall be designed to prevent water intrusion into the building. CGC Section 5.407.2.2.1. Waste management. Note on the plans that the contractor must submit to the Engineering Department or other Agency that regulates construction waste management a Waste Management Plan that outlines the items listed in CGC Section 5.408.1.1. Recycling. Note on the plans that a minimum of 65% of construction waste is to be recycled and/or salvaged. CGC 5.408.1. Documentation shall be provided to the enforcing agency which demonstrates compliance. CGC Section 5.408.1.4. Waste reduction. Note on the plans that 100% of trees, stumps, rocks, and associated vegetation and soils primarily from the construction will be reused or recycled. CGC 5.408.3. Recycling. Note on the plans that an identified, readily accessible area shall be provided that serves the entire building for collecting recycling, such as paper, cardboard, glass, plastics, metals, etc. CGC Section 5.410.1. Commissioning. For new buildings that are 10,000 sq. ft. and over, the architect or responsible design professional shall submit, prior to plan approval, a "Commissioning Plan". CGC Section 5.410.2. The Commissioning Plan must be submitted with the plan documents during plan check. The Plan must be reviewed and approved by the plan checker for compliance with the required features listed in CGC 5.410.2.3 as follows: (a) General project information (b) Commissioning goals (c) List the systems to be commissioned with information on design intent, equipment and systems to be tested, functions to be tested and acceptable performance based on tests (d) Commissioning Team information (e) Commissioning process activities, schedules and responsibilities. Documentation. Note on the plans that a building "Systems Manual" as listed in CGC Section 5.410.2.5 shall be delivered to the building owner or representative and the facilities operator. Further, note on the plans that the "Systems Manual" shall contain the required features listed in CGC Section 5.410.2.5.1. Pollutant control. Note on the plans that during construction, ends of duct openings are to be sealed, and mechanical equipment is to be covered. CGC 5.504.3. Pollutant control. Note on the plans that VOC's must comply with the limitations listed in Section 5.504.4 and Tables 4.504.1, 5.504.4.1 5.504.4.2, 5.504.4.3 and 5.504.4.5 for: Adhesives, Sealants, Paints and Coatings, Carpet and Composition Wood Products. CGC 5.504.4. Pollutant control. Note on the plans that mechanically ventilated buildings shall provide regularly occupied areas with air filtration media for outside and return air that provides at least a Minimum Efficiency Reporting Value (MERV) of 8. MERV 8 filters shall be installed prior to occupancy. CGC Section 5.504.5.3. Pollutant control. Note on the plans that where outdoor areas are provided for smoking, such areas are prohibited within 25' of building entries, windows and outdoor air intakes. Signage shall be posted to inform occupants of the prohibitions. CGC Section 5.504.7. Environmental comfort. Note on the plans that wall and floor assemblies separating tenant spaces (and tenant spaces from public spaces) shall have an STC of at least 40. CGC Section 5.507.4.3. Environmental comfort. Wall and roof assemblies exposed to noise sources shall have an STC rating of at least 50, with exterior windows having a minimum STC of 40 in the following locations, per CGC Section 5.507.4.1: Within the 65 CNEL noise contour of a freeway, railroad or industrial source, as determined by the jurisdiction's Noise Element of the General Plan. Within the 65 CNEL noise contour of an airport. Outdoor air quality. Note on the plans that installations of HVAC, refrigeration and fire suppression systems will not contain CFC's or Halons, per CGC 5.508.1. Supermarket refrigerant leak reduction. Note on the plans that new commercial refrigeration systems shall be shown to comply with Section 5.508.2 when installed in retail food stores 8,000 square feet or more conditioned area and that utilize either refrigerated display cases or walk-in coolers/freezers connected to remote compressor units. Indoor water use. For new buildings, show on the site utility plan separate sub- meters per CGC Section 5.303.1 for the following: (a) Each leased or owned space that consumes more than 100 gal/day (b) Tenant spaces containing laundry, cleaners, restaurant, medical/dental office, laboratory or beauty/barber shops. Water reduction. Show on the plans the following maximum fixture flow rates from the table below. Revise general notes, plumbing plans, etc. to match. CGC 5.303. MAXIMUM FIXTURE FLOW RATES FIXTURE TYPE MAXIMUM FLOW RATE Water closets 1.28 gallons/flush Urinals (wall mounted) 0.125 gallons/flush Urinals (floor mounted) 0.5 gallons/flush Showerheads 1.8 gpm © 80 psi Lavatory faucets- nonresidential 0.5 gpm @60 psi Kitchen faucets 1.8 gpm @ 60 psi Metering faucets 0.2 gallons/cycle When a shower is provided with multiple shower heads, the sum of flow to all the heads shall not exceed 1.8 gpm, or the shower shall be designed so that only one head is on at a time. CGC 5.303.3.3.2. Outdoor water use. Note on the plans that a water budget shall be developed for landscape irrigation use that conforms to Section 5.304. Note on the plans that prior to final inspection the licensed contractor, architect or engineer in responsible charge of the overall construction must provide to the building department official written verification that all applicable provisions from the Green Building Standards Code have been implemented as part of the construction. CGC 102.3. DISABLED ACCESS REVIEW LIST DEPARTMENT OF STATE ARCHITECT TITLE 24 The following disabled access items are taken from the 2016 edition of California Building Code, Title 24. Per Section 1.9.1, all publicly and privately funded public accommodations and commercial facilities shall be accessible to persons with disabilities. REMODELS, ADDITIONS AND REPAIRS 41. When alterations, structural repairs or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the following requirements, per Section 11 B-202.4: The area of specific alteration, repair or addition must comply as "new" construction. A primary entrance to the building and the primary path of travel to the altered area, must be shown to comply with all accessibility features. The path of travel shall include the existing parking. Existing toilet and bathing facilities that serve the remodeled area must be shown to comply with all accessibility features. Existing drinking fountains (if any) must be shown to comply with all accessibility features. Existing public telephones (if any) must be shown to comply with all accessibility features. Existing signage. a) Exceptions: i) When the adjusted construction cost is less than the current valuation threshold (currently $166,157), the cost of compliance shall be limited to 20% of the adjusted construction cost. Section 11 B- 202.4, Exception 8. If this exception is chosen, please provide documentation to show how the money will be spent. Priority should be given to those elements that will provide the greatest access. The order of priority shown below should be followed: An accessible entrance. An accessible route to the altered area. At least one accessible restroom for each sex. Accessible telephones. Accessible drinking fountains. When possible, additional accessible elements such as parking, storage and alarms. DOORS 42. Show or note that all hand-activated door opening hardware meets the following requirements, per Section 11 B-404.2.7: Latching, or locking, doors in a path of travel are operated with a single effort by lever type hardware, by panic bars, push-pull activating bars, or other hardware designed to provide passage without requiring the ability to grasp the opening hardware. Is to be centered ~34" but :544" above floor. 43. Show or note that the maximum effort to operate doors shall not exceed 5 pounds, with such pull or push effort being applied at right angles to hinged doors and at the center plane of sliding or folding doors. When fire doors are utilized, the maximum effort to operate the door may be increased to not exceed 15 pounds. Section 11 B-404.2.9. 44. Show or note that the lower 10" of all doors comply with Section 11 B-404.2.10, as follows: To be smooth and uninterrupted, to allow the door to be opened by a wheelchair footrest, without creating a trap or hazardous condition. Narrow frame doors may use a 10" high smooth panel on the push side of the door. STAIRWAYS AND HANDRAILS 45. Show that handrails are provided on each side of the stairs, per Section 1113- 505.2. 46. Provide sections, details or notes to show that handrails are to be located ~!34" but :538" above nosing of treads, per Section 11 B-505.4. 47. Show that handrails extend ~12" beyond top nosing, and ~12"-plus-tread-width beyond the bottom nosing. At the top, the extension shall be parallel with the floor. At the bottom, the handrail shall continue to slope for a distance of one tread width; the remainder of the extension shall be horizontal. The extensions of handrails shall be in the same direction of the stair flights. Section 1113- 505.10. 12MIP& THEM DMAWSMSIMIt ThE $KCFIC RJMEU1S 4LYMAIAO PIGW 1B-W3GAWD$ACIV1ON$ 48. Per Section 11 B-505.7, provide details, sections or notes to show that handgrip portions of handrails are: ~1%" and :52" in cross sectional dimension. The shape may provide an equivalent gripping surface. The handgrip portion shall have a smooth surface, without any sharp corners. 49. Stair treads shall be no less than 11" deep, measured from riser to riser. Section 11 B-504.2. This applies even if basic CBC provisions may allow a narrower tread. 50. Show or note that interior stair treads are marked at the upper approach and the lower tread of each stair, by a strip of clearly contrasting color, per Section 11 B- 504.4.1, as follows: At least 2" wide (but not more than 4" wide). Placed parallel to and not more than 1" from the nose of the step or landing. The strip shall be as slip resistant as the other treads of the stair. 51. Note that all tread surfaces comply with Section 11 B-504.3 and 11 B-504.5, as follows: Open risers are not permitted. Stair treads shall be no less than 11" deep, measured from riser to riser. C) Be slip resistant. Have smooth, rounded or chamfered exposed edges. Have no abrupt edges at the nosing. Nosing shall not project> 1%" past the face of the riser above. 52. If showers are proposed, show or note compliance with the following requirements, per Section 11 B-608: a) Size and Clearance. Accessible showers shall comply with one of the following: Transfer type shower 36"x36" clear inside dimension with a 36" wide entry minimum. A clearance of 36" x48" shall be provided outside of the shower for side transfer into the shower. 11 B-608.2.1. Standard roll-in shower 60 inches minimum in width between wall surfaces and 30 inches in depth with a full opening width on the long side. Shower compartment size and clear floor space shall comply with Figure 11 B-608.2.2. Alternate roll-in shower 60 inches minimum in width between the wall surfaces and 36 inches in depth with an entrance opening width of 36 inches minimum. Shower compartment size and clear floor space shall comply with Figure 11 B-608.2.3. b) Threshold in roll-in type showers shall be 1/2 inch in high maximum. c) Where within the same functional area, two or more accessible showers are provided, there shall be at least one shower constructed opposite hand from the other or others (i.e., one left-hand control versus right-hand control). Section 11 B-213.3.6. d) Water controls shall be of a single-lever design, operable with one hand, and shall not require grasping, pinching or twisting of the wrist. The controls shall be on the back wall, adjacent to the seat, and the center line of the controls shall be located 39" —41" above the shower floor. i) In transfer type showers the controls, faucet, and shower spray unit shall be installed on the side wall opposite the seat 38" to 48" maximum above the shower floor, on the control wall 15" maximum from the centerline of the seat toward the shower opening. e) A flexible hand-held shower unit is required with at least a hose 59 inches long that can be both used as a fixed shower head and hand-held. This unit shall be mounted such that the top of the mounting bracket is a maximum of 48 inches above the shower floor. f) Two wall-mounted heads may be installed in lieu of the hand-held unit in areas subject to excessive vandalism. (Except within guest room and suites of hotels, motels and similar transient lodging establishments) Each shower head shall be installed so that it can be operated independently of the other and shall have swivel angle adjustments both vertically and horizontally. One head shall be located at a height of 48 inches above the floor. The floor slope shall be a maximum of 1:48 in any direction. Where drains are provided, the grate shall. have openings % inch maximum and located flush with the floor surface. Indicate on the plans a folding seat, located on the wall adjacent to the controls, 18" above the floor and shall not extend more than 6 inches from the wall. Grab bars shall be located, per Section 608.3: On the back wall and the side wall opposite the seat. Mounted ~33" but :536" above the shower floor. Grab bars shall not extend into that portion of the wall over the seat. In transfer type showers, grab bars shall be located across the control wall and back wall to a point 18" from the control wall. 53. The soap dish when provided shall be located on the control wall :540" above the shower floor and within reach limits from the seat. DRINKING FOUNTAINS 2. Plans shall indicate that drinking fountains comply with Section 11 B-602.9 as either: Located completely in an alcove, ~32" in width and ~18" in depth. Positioned completely between wing walls. Positioned to not encroach into accessible pedestrian ways. 3. The drinking fountain shall be a minimum of 18 inches in depth and there shall be clear and unobstructed knee space under the drinking fountain not less than 27 inches in height and 8 inches in depth, the depth measurements being taken from the front edge of the fountain. Additionally, there shall be toe clearance of 9 inches in height above the floor and 17 inches in height above the floor and 17 inches in depth from the front edge of the fountain. A side approach drinking fountain is not acceptable. Section 11 B-602. 4. Drinking fountains shall be accessible to individuals who use wheelchairs and to those who have difficulty bending or stooping. This can be accommodated by the use of "hi-low" fountains. Section 11 B-211.2. 5. Note on the plans that the drinking fountain(s) will comply with all applicable Title 24 provisions (bubbler height, etc.). CONTROLS AND OPERATING MECHANISMS 6. Note on the plans that controls and operating mechanisms shall comply with the requirements of Section 11 B-309. 7. The highest and lowest operable parts of all controls, dispensers, receptacles and other operable equipment shall be placed within 48" of the floor but not lower than 15" for forward approach (or within 54" but not lower than 9" if side approached). Electrical and communication system receptacles on walls shall be mounted no less than 15" above the floor. Section 11 B-308. SIGNAGE 54. Per Section 1013.4, tactile exit signs shall be required at the following locations: a) Wherever basic CBC provisions require exit signs from a room or area to a corridor or hallway. The tactile exit sign shall have the words, "EXIT ROUTE." b) Each grade-level exit door. The tactile exit sign shall have the word, "EXIT." c) Each exit door that leads directly to a grade-level exterior exit by means of a stairway or ramp. The tactile exit sign shall have the following words as appropriate: "EXIT STAIR DOWN" "EXIT RAMP DOWN." "EXIT STAIR UP." "EXIT RAMP UP." d) Each exit door that leads directly to a grade-level exterior exit by means of an exit enclosure or an exit passageway. The tactile exit sign shall have the words, "EXIT ROUTE." e) Each exit door through a horizontal exit. The tactile exit sign shall have the words, "TO EXIT." 55. Tactile stair level identification signs (complying with Section 11 B-703) shall be located at each floor level landing in all enclosed stairways in buildings two or more stories in height to identify the floor level. At the exit discharge level, the sign shall include a raised five-pointed star located to the left of the identifying floor level. Section IIB-216.4.1. 56. Where permanent identification is provided for rooms and spaces, raised letters shall also be provided and shall be accompanied by Braille. Section 11B-216.2. 57. Provide a note on the plans stating that the signage requirements of Sections 11 B- 216 and 11 B-703 will be satisfied. ADDITIONAL To speed up the review process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: 0 Yes 0 No The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Steven Miller at Esgil. Thank you. END OF DOCUMENT (DO NOT PAY— THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK#.: CBC2020-0221 PREPARED BY: Steven Miller DATE: 6/29/2020 BUILDING ADDRESS: 2810 Caribou Court BUILDING OCCUPANCY: B,S1,A BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) TI 5413 251,758 Air Conditioning Fire Sprinklers TOTAL VALUE 251,758 Jurisdiction Code ICB ]By Ordinance 1997 UBC Building Permit Fee [J 11997 UBC Plan Check Fee L!J I •Al• .041 Type of Review: P Complete Review r Structural Only I rRepieFee FERepeats r- Other r Hourly 1Hr. @* EsGil Fee P, I $757.681 Comments: Sheet 1 of 1 STRUCTURAL CALCULATIONS PROJECT: z. ,E. ( S tr-&ie iI ESlGNSSUMFflONS CONCRETE STRENGTH AT TWENTY EIGHT DAYS: PSI MASONRY: GRADE 'N" CONCRETE BLOCK F' M = PSI MORTAR: TYPES 1800 PSI GROUT: 2000 PSI H TK StRUcTUAiNGK%JEEHS, LLP REINFORCING STEEL. A-615 GRADE 40: #4 AND LESS (U.0 GRADE 60: #5 AND LARGER STRUCTURAL STEEL: A-36 LUMBER: DOUGLAS FIR-LARCH JOISTS #2 j BEAMS AND POSTS #2 STUDS STUD OR BETTER SEISMIC FORCE:. J L4 REPORT BY: WIND FORCE: - REPORT NO.: - _...- SOIL PRESSURE: DGNWA ROOF DEAD LOAD FLOOR DEAD]..OAD WALLDEADLOAD SLOPING BA! M./ C) ROOFING FLOORING INTERIOR 10 PSF PLYWOOD PLYWOOD / EXTERIOR 16 PSF JOISTS JOISTS SNSUL. & CLG. JNSUL & CLG. MISC. MISC. TOTAL - TOTAL ROOF LIVE LOAD FLOOR-LIVE LOAD SLOPING = p INTERIOR 40 PSF FLAT= £ BALCONY 60 PSF (U.O.N.) EXIT WALKWAY 100 PSF These calculations are limited only to the Items Induded herein, selected by the cl i e n t a n d d o n o t i m p l y a p p r o v a l o f a n y other portion of the structure by this office. These calculations are not valid If altered In a n y w a y , o r n o t a c c o m p a n i e d b y a stamp and signature of the Engineer of Record. l.a Diego 1411$ Isaiah.. It,..,. lufta I lii. Poway. CA 11111. 16921 Ill-Slip. Pa. (Ill) Ill-ISIS c)a)Ca0zo- ozi Temecula a Island ?ntial 333 ft abital... w Cleveland National Forest o f Anza-Boi Carlsbad Deset State P WC Hazards by Location Search Information Address: Caribou Ct, Carlsbad, CA 92010, USA Coordinates: 33.1400185.-117.2543253 Elevation: 333 ft Timestamp: 2020.08-12121:50:28.037Z Hazard Type: Seismic Reference ASCE7-16 Document: Risk Category: ii Sits Class: D-defauit Gorgie San Dieio 0 Map date O.R*IpOT. Basic Parameters Name Value Description 58 0.93 MCER ground motion (perlod0.29) Si 0.342 MCE1 ground motion (perlod=1.os) SMSr 1.116 Site-modified spectral acceleration value SM1 J null Site-modified spectral acceleration value r 0.744 Numeric seismic design value at 0.2s SA 5D1 * null Numeric seismic design value at 1.08 SA * See Section 11.4.8 'Additional Information Name Value Description SDC null Seismic design category F8 1.2 Site amplification factor at 0.2e F null Site amplification factor at 1.09 CRS 0.908 Coefficient of risk (0.28) CR1 0.916 Coefficient of risk (1.09) PGA 0.404 MCEG peak ground acceleration PGA 1.2 Site amplification factor at PGA PGAM 0.485 Site modified peak ground acceleration 1 ,0 U c!E& ( f pli fap%It __ Too4-Lr ls1 = epr 3 -W4- DIS5 50, c24(k Cis) Oa T 44, 4. Uft..iFr Liip = LID(1stC -- L RE& APiCAI, C4r.A\I. L a it o cs,D -1 S24 L , , rZ $ we -:. 2.4c 1. d 424I LUE 4-' !7rLl .-)fO I r- 7sL, T?Wsles . - 1,d 1 Pea.. 7-/Ev.Si jc Th(sE3 At-e- e-loan ta-. SAN DIEGO REGIONAL OFFICE USE ONLY HAZARDOUS MATERIALS RECORD ID 9 PLAN CHECK # Ca C 711L0 —n2 I OCCC QUESTIONNAIRE BP DATE I i, 120' Business Name Business Contact Telephone # Zense-Life Inc. Leif Bowman 858-888-5289 Project Address City State Zip Code APN# 2810 Caribou Court, Suite 110, Carlsbad, CA 92010 Mailing Address City State Zip Code Plan File# 2810 Caribou Court, Suite 110, Carlsbad, CA 92010 Project Contact Applicant E-mail' Telephone # Leif Bowman lbowman@zense.life.com 858-888-5289 The following questions represent the facility's activities, NOT the specific project description. uiegop: inaicate oy circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Occupancy Rating: Facility's Square Footage (including proposed project): Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives Ciosiv?Th Com 6. Oxidizers 10. C 14. Other Health Hazards lammable/Combustible Liqui s 7. Pyrophorics . Highlyli ves r Toxic Materia 15, None of These. 4. 8. Unstable Reactives 12. Ra io PART It: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH — HAZARDOUS MATERIALS DIVISION (HMD): If the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overland Avenue, Suite 110, San Diego, CA 92123. Call (858) 505-6700 prior to the issuance of a building permit. FEES ARE REQUIRED Project Completion Date: Expected Date of Occupancy: 0 CalARP Exempt YES NO (for new construction or remodeling projects) / 0 0 Is your business listed on the reverse side of this form? (check all that apply). Date Initials 0 0 Will your business dispose of Hazardous Substances or Medical Waste in any amount? 0 El Will your business store or handle Hazardous Substances in quantities greater than or equal to 55 gallons, 500 0 CalARP Required pounds and/or 200 cubic feet? I 0 El Will your business store or handle carcinogens/reproductive toxins in any quantity? Date Initials 0 El Will your business use an existing or install an underground storage tank? 0 0 Will your business store or handle Regulated Substances (CaIARP)? 0 CaIARP Complete 0 0 Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? / 0 El Will your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to Date Initials or greater than _1,320_ gallons? _(California's Aboveground _Petroleum _Storage Act). PART III: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT (APCD): Any YES answer requires a stamp from APCD 10124 Old Grove Road, San Diego, CA 92131 aDcdcomosdcounty.ca.ov (858) 586-2650). [*No stamp required if Qi Yes and Q3 Yes and Q4-06 No]. The following questions are intended to identify the majority of air pollution issues at the planning stage. Projects may require additional measures not identified by these questions. For comprehensive requirements contact APCD. Residences are typically exempt, except - those with more than one building on the property; single buildings with more than four dwelling units; townhomes; condos; mixed-commercial use; deliberate burns; residences forming part of a larger project. [Excludes garages & small outbuildings.] YES NO 0 El Will the project disturb 160 square feet or more of existing building materials? 0 El Will any load supporting structural members be removed? Notification may be required 10 working days prior to commencing demolition. 0 0 (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Has an asbestos survey been performed by a Certified Asbestos Consultant or Site Surveillance Technician? 0 0 (ANSWER ONLY IF QUESTION 3 IS YES) Based on the survey results, will the project disturb any asbestos containing material? Notification may be required 10 working days prior to commencing asbestos removal. 0 El Will the project or associated construction equipment emit air contaminants? See the reverse side of this form or APCD factsheet (www.sdaocd.orci/info/facts/permits.pdfl for typical equipment requiring an APCD permit. 0 0 (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located within 1,000 feet of a school boundary Briefly describe business activities: Briefly describe proposed project: Medical device R&D Office Ti. Scope includes adding open office, restrooms. shower, conference rooms and work room to warm shell. I declare under penalty of perjury that to the best of my knowledge and bMIUM es made herein are true and correct. _________________ 06 /15 /2020 Name of Owner or Authorized Agent Signature of Owner or Authorized Agent Date FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: FOR OFFICAL USE ONLY: BY: DATE: EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR occucv COUNTYHMD* APCD COUNTY-HMD APCD COUNTY-HMD APCD A stamp in this box only exempts businesses from completing or updating a Hazardous Materials Business Plan. Other permitting requirements may still apply. HM-9171 (08/15) County of San Diego - DEH - Hazardous Materials Division LIST OF BUSINESSES WHICH REQUIRE REVIEW AND APPROVAL FROM THE COUNTY OF SAN DIEGO DEPARTMENT OF ENVIRONMENTAL HEALTH - HAZARDOUS MATERIALS DIVISION Check all that apply: AUTOMOTIVE Battery Manufacturing/Recycling Boat Yard Car Wash C1 Dealership Maintenance/Painting El Machine Shop El Painting C] Radiator Shop Rental Yard Equipment Repair/Preventive Maintenance Spray Booth Transportation Services Wrecking/Recycling CHEMICAL HANDLING Agricultural supplier/distributor Chemical Manufacturer Chemical Supplier/Distributor El Coatings/Adhesive Compressed Gas Supplier/Distributor 0 Dry Cleaning Fiberglass/Resin Application Gas Station Industrial Laundry Laboratory Laboratory Supplier/Distributor Oil and Fuel Bulk Supply Pesticide Operator/Distributor CHEMICAL HANDLING Photographic Processing Pool Supplies/Maintenance El Printing/Blue Printing Road Coatings Swimming Pool Toxic Gas Handler Toxic Gas Manufacturer METAL WORKING Anodizing Chemical Milling/Etching Finish-Coating/Painting Flame Spraying Foundry Machine Shop-Drilling/Lathes/Mills Metal Plating Metal Prepping/Chemical Coating Precious Metal Recovery Sand Blasting/Grinding El Steel Fabricator Wrought Iron Manufacturing AEROSPACE Aerospace Industry C1 Aircraft Maintenance Aircraft Manufacturing OTHERS AND MISCELLANEOUS El Asphalt Plant LII Biotechnology/Research El Chiropractic Office El Co-Generation Plant El Dental Clinic/Office El Dialysis Center El Emergency Generator El Frozen Food Processing Facility El Hazardous Waste Hauler El Hospital/Convalescent Home El Laboratory/Biological Lab El Medical Clinic/Office El Nitrous Oxide (NO.) Control System El Pharmaceuticals C1 Public Utility El Refrigeration System Rock Quarry El Ship Repair/Construction Telecommunications Cell Site Veterinary Clinic/Hospital El Wood/Fumiture Manufacturing/Refinishing ELECTRONICS El Electronic Assembly/Sub-Assembly El Electronic Components Manufacturing El Printed Circuit Board Manufacturing NOTE: THE ABOVE LIST INCLUDES BUSINESSES, WHICH TYPICALLY USE, STORE, HANDLE, AND DISPOSE OF HAZARDOUS SUBSTANCES. ANY BUSINESS NOT INCLUDED ON THIS LIST, WHICH HANDLES, USES OR DISPOSES OF HAZARDOUS SUBSTANCES MAY STILL REQUIRE HAZARDOUS MATERIALS DIVISION (HMD) REVIEW OF BUSINESS PLANS. FOR MORE INFORMATION CALL (858) 505-6880. LIST OF AIR POLLUTION CONTROL DISTRICT PERMIT CATEGORIES Businesses, which include any of the following operations or equipment, will require clearance from the Air Pollution Control District. CHEMICAL 47—Organic Gas Sterilizers 32 -Acid Chemical Milling 33— Can & Coil Manufacturing 44— Evaporators, Dryers & Stills Processing Organic Materials 24— Dry Chemical Mixing & Detergent Spray Towers 35— Bulk Dry Chemicals Storage 55 - Chrome Electroplating Tanks COATINGS & ORGANIC SOLVENTS 27— Coating & Painting Plasma Arc & Ceramic Deposition Spray Booths Paint, Stain & Ink Mfg 27— Printing 27— Polyester Resin/Fiberglass Operations METALS 18— Metal Melting Devices 19 - Oil Quenching & Salt Baths 32 - Hot Dip Galvanizing 39 - Precious Metals Refining ORGANIC COMPOUND MARKETING (GASOLINE, ETC) 25— Gasoline & Alcohol Bulk Plants & Terminals 25— Intermediate Refuelers 26 - Gasoline & Alcohol Fuel Dispensing COMBUSTION 34— Piston Internal - Combustion Engines 13— Boilers & Heaters (1 million BTU/hr or larger) 14 - Incinerators & Crematories 15— Burn Out Ovens 16— Core Ovens 20— Gas Turbines, and Turbine Test Cells & Stands 48 - Landfill and/or Digester Gas Flares ROCK AND MINERAL Hot Asphalt Batch Plants Rock Drills 06 - Screening Operations 07—Sand Rock & Aggregate Plants 08— Concrete Batch, CTB, Concrete Mixers, Mixers & Silos 10— Brick Manufacturing OTHER 01 -Abrasive Blasting Equipment 03—Asphalt Roofing Kettles & Tankers 46— Reverse Osmosis Membrane Mfg 51 -Aqueous Waste Neutralization 11 - Tire Buffers 17— Brake Debonders 23— Bulk Grain & Dry Chemical Transfer & Storage 45 - Rubber Mixers 21 -Waste Disposal & Reclamation Units 36 - Grinding Booths & Rooms 40—Asphalt Pavement Heaters 43— Ceramic Slip Casting 41 - Perlite Processing 40— Cooling Towers - Registration Only 91 - Fumigation Operations 56 —tMNTP (1 million gal/day or larger) & Pump Station ELECTRONICS 29— Automated Soldering 42 - Electronic Component Mfg FOOD 12— Fish Canneries 12— Smoke Houses 50— Coffee Roasters 35— Bulk Flour & Powered Sugar Storage SOLVENT USE 28—Vapor & Cold Degreasing 30— Solvent & Extract Driers 31 -Dry Cleaning NOTE: OTHER EQUIPMENT NOT LISTED HERE THAT IS CAPABLE OF EMITTING AIR CONTAMINANTS MAY REQUIRE AN AIR POLLUTION CONTROL DISTRICT PERMIT. IF THERE ARE ANY QUESTIONS, CONTACT THE AIR POLLUTION CONTROL DISTRICT AT (858) 586-2600. HM-91 71(08/15) County of San Diego - DEH - Hazardous Materials Division I ENCINA WASTEWATER AUTHORITY INDUSTRIAL WASTEWATER DISCHARGE PERMIT SCREENING SURVEY 6200 Avenida Encinas, Carlsbad, CA 92011 Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinajpa.com Date:06152020 Business Name: Zense-Life Inc. Street Address: 2810 Caribou Court Email Address:Ibowman@zense-Iife.com PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT: (ON REVERSE SIDE CHECK TYPE OF BUSINESS) Check all below that are present at your facility: Acid Cleaning o Food Processing Assembly o Glass Manufacturing Automotive Repair o Industrial Laundry Battery Manufacturing o Ink Manufacturing Biofuel Manufacturing o Laboratory Biotech Laboratory o Machining/Milling Bulk C emica Storage o Membrane manufacturing Car Wash (i.e. water filter membranes) Chemical Manufacturing o Metal Casting/Forming Chemical Purification o Metal Fabrication Dental Offices o Metal Finishing Dental Schools Electroplating Dental Clinics Electroless Plating Dry Cleaning Anodizing Electrical Component Coating (i.e. phosphating) Manufacturing Chemical Etching/Milling Fertilizer Manufacturing Printed Circuit Board Film/X-ray Processing Manufacturing Metal Powders Forming Nutritional Supplement/Vitamin Manufacturing Painting/Finishing Paint Manufacturing Personal Care Products Manufacturing Pesticide Manufacturing/ Packaging Pharmaceutical Manufacturing (including precursors) Porcelain Enameling Power Generation Print Shop Research and Development Rubber Manufacturing Semiconductor Manufacturing Soap/Detergent Manufacturing Waste Treatment/Storage New Business? YesIINoI SIC Code(s) if known: Date operation began/will begin:_________________ Tenant Improvement? YesNol If yes, briefly describe improvement:_________________________________________ Office T.I. Scope includes adding open office, restrooms, shower, conference rooms and work room Description of operations generating wastewater (discharged to sewer, hauled or evaporated):____________________________ Estimated volume of industrial wastewater to be discharged (gal/ day): List hazardous wastes generated (type/volume):______________________________________________________________________ Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authority? Yeslil Date: Noü Page 1of 2 ENCINA WASTEWATER AUTHORITY INDUSTRIAL WASTEWATER DISCHARGE PERMIT SCREENING SURVEY JJR 6200 Avenida Encinas, Carlsbad, CA 92011 Phone: 760438-3941 Fax: 760-476-9852 - SourceControlencinajpa.com The commercial enterprises listed below are a partial listing of businesses that are exempt from industrial wastewater discharge permitting under normal operating conditions. They are exempt because (a) they discharge no process wastewater (i.e., they only discharge sanitary wastewater with no pollutants exceeding any local limits), and (b) they have no potential to negatively impact the EWPCF or other wastewater treatment plants in the ESS. Any questions regarding exemptions should be referred to EWA Source Control staff. Automobile Detailers Barber/Beauty Shops Business/Sales Offices Cleaning Services Carpet/Upholstery Childcare Facilities Churches Community Centers Consulting Services Contractors Counseling Services Educational Services (no auto repair/film developing) Financial Institutions/Services Fitness Centers Gas Stations (no car wash/auto repair) Grocery Stores (no film developing) Residential based Businesses Hotels/Motels (no laundry) Laundromats Libraries Medical Offices (no x-ray developing) Mortuaries Museums Nail Salons Nursing Homes Office Buildings (no process flow) Optical Services Pest Control Services (no pesticide repackaging for sale) Pet Boarding/Grooming Facilities Postal Services (no carwash/auto repair) Public Storage Facilities Restaurants/Bars Retail/Wholesale Stores (no auto repair/film developing) Theaters (Movie/Live) CERTIFICATION STATEMENT I certify that the information above is true and correct to the best of my knowledge. Signature:LZ._..__,__ Print Name:Leif Bowman DATE: 06.15.2020 Facility Contact: Leif Bowman Title: CEO ENCINA WASTEWATER AUTHORITY 6200 AVENIDA ENCINAS, CARLSBAD, CA Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinaipa.com Page 2 of 2 (city of Carlsbad CLIMATE ACTION PLAN CONSISTENCY CHECKLIST B-50 Development Services Building Division 1635 Faraday Avenue (760) 602-2719 www.carlsbadca.gov PURPOSE This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their projects. The completed checklist must be included in the building permit application. It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as specified by the ordinances. NOTE: The following type of permits are not required to fill out this form . Patio 1 •:• Decks 1 •• PME (w/o panel upgrade) •• Pool .4 If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, an explanation must be provided to the satisfaction of the Building Official. A Details on CAP ordinance requirements are available on the city's website. .4 A CAP Building Plan template (form B-55) shall be added to the title page all building plans. This template shall be completed to demonstrate project compliance with the CAP ordinances. Refer to the building application webpage and download the latest form. Application Information Project Name/Building Permit No.: Zense-Life Suite 110- Office BP No.: Property Address/APN: 2810 Caribou Court, Suite 110, Carlsbad, CA 92010 209-120-03-00 Applicant Name/Co.: Zense-Life Inc. - Leif Bowman Applicant Address: 2810 Caribou Court, Suite 110, Carlsbad, CA 92010 Contact Phone: 858-888-5289 Contact Email: Ibowmanczense-Iife.com Contact information of person completing this checklist (if different than above): Name: Heather Moore Contact Phone: 619-569-5633 Company name/address: Ware Malcomb Contact Email: hmoore@waremalcomb.com 3911 Sorrento Valley Blvd., Ste, 120 Applicant Signature: W19vt Date: 06.15.2020 B-50 Page 1 of 6 Revised 08/19 City of Carlsbad Climate Action Plan Consistency Checklist Use the table below to determine which sections of the Ordinance compliance checklist are applicable to your project. I For alterations and additions to existing buildings, attach Building Permit Valuation worksheet. Building Permit Valuation (BPV) from worksheet: $ 458.00000 Construction Type Complete Section(s) J Notes: A high-rise residential building is 4 or more stories, including a Residential Low-rise High-rise mixed-use building in which at least 20% of its conditioned floor area is residential use New construction 2A, 3A, 4A 1B, 2B, 3B, 4A 0 Additions and alterations: BPV < $60,000 N/A N/A All residential additions and alterations BPV a $60,000 IA 4A 4A 1-2 family dwellings and townhouses with attached garages Electrical service panel upgrade only ' only *Multi-family dwellings only where interior finishes are removed BPV 2:$200,000 1A, 4A* I B, 4A* and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed L?J Nonresidential 0 New construction 1B, 2B, 3B, 4B and 5 IZI Alterations: El BPV a $200,000 or additions 1,000 lB 5 square feet BPV 2t $1,000,000 1B, 2B, 5 2t 2,000 sq. ft. new roof addition 2B, 5 Building alterations of 2t 75% existing gross floor area I B also applies if BPV 2: $200,000 CAP Ordinance Compliance Checklist Item Check the appropriate boxes, explain all not applicable and exception items, and provide supporting calculations and documentation as necessary. 1. Energy Efficiency Please refer to Cadsbad Municipal Code (CMC) sections 18.21.155 and 18.30.190, and the California Green Building Standards Code (CALGreen) for more information when completing this section. A U Residential addition or alteration 2 $60,000 building permit valuation. 0 N/A_____________________________ See CMC section 18.30.190. 0 Exception: Home energy score a 7 (attach certification) Year Built Single-family Requirements Multi-family Requirements Before 1978 Select one: Duct sealing 0 Attic insulation 0 Cool roof 0 Attic insulation 1978 and later Select one: Lighting package 0 Water heating Package Between 1978 and 1991 Select one: Duct sealing 0 Attic insulation 0 Cool roof 1992 and later Select one: Lighting package 0 Water heating package B. RI Nonresidential* new construction or alterations 2 $200,000 building permit valuation, or additions 21,000 square feet. 0 N/A Updated 8/15/2019 2 City of Carlsbad Climate Action Plan Consistency Checklist See CMC 18.21 .155 and CALGreen Appendix A5, Division A5.2 - Energy Efficiency. A5.203.1.1 Choose one: 0.1 Outdoor lighting 0.2 Warehouse dock seal doors 0.3 Restaurant service water heating (comply with California Energy Code section 140.5, as amended) 0 N/A_____________________________ 0.4 Daylight design PAFs 0.5 Exhaust air heat recovery A5.203.1.2.1 Choose one as applicable: 0.95 Energy budget 0.90 Energy budget 0 N/A_____________________________ A5.211.1" On-site renewable energy o N/A_____________________________ A5.211.3** Green power (if offered by local utility provider, 50% minimum renewable sources) 0 N/A_____________________________ A5.212.1 Elevators and escalators 0 N/A___________________________ A5.213.1 Steel framing 0 N/A______________________ * Includes hotels/motels and high-rise residential buildings "For alterations 211,000,000 BPV and affecting >75% existing gross floor area, or alterations that add 2,000 square feet of new roof addition: comply with CMC 18.30.130 instead. 2. Photovoltaic Systems fl Residential new construction (for low-rise residential building permit applications submitted after 111120). Refer to 2019 California Energy Code section 150.1(c)14 for requirements. Notes: 1) High-rise residential buildings are subject to nonresidential photovoltaic requirement (213 below) instead. 2) If project includes installation of an electric heat pump water heater pursuant to CMC 18.30.150(B) (high-rise residential) or 18.30.170(B) (low-rise residential), increase system size by .31dNdc if PV offset option is selected. Floor Plan ID (use additional sheets if necessary) CFA #d.u. Calculated kWdc* Exception Total System Size: kWdc kWdc = (CFAx.572) /1,000 + (1.15 x #d.u.) *Formula calculation where CFA = conditional floor area, #du = number of dwellings per plan type If proposed system size is less than calculated size, please explain. [] Nonresidential new construction or alterations 2$1,000,000 BPV and affecting 2750/6 existing floor area, or addition that increases roof area by 22,000 square feet. Please refer to CMC section 18.30.130 when completing this section. Note: This section also applies to high-rise residential and hotel/motel buildings. Choose one of the following methods: 0 Gross Floor Area (GFA) Method GFA: Mm. System Size: kWdc If < 10,000s.f. Enter: 5 kWdc If 2: 10,000s.f. calculate: 15 kWdc x (GFNI0,000) ** **Round building size factor to nearest tenth, and round system size to nearest whole number. 0 Time- Dependent Valuation Method Updated 8/15/2019 3 City of Carlsbad Climate Action Plan Consistency Checklist Annual TDV Energy use:*** x.80= Mm. system size: kWdc ***Attach calculation documentation using modeling software approved by the California Energy Commission. 3. Water Heating Residential and hotel/motel new construction Please refer to CMC sections 18.30.150 and 18.30.170 when completing this section. E] For systems serving individual dwelling units choose one: El Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise residential only) Heat pump water heater AND PV system .3 kWdc larger than required in CIVIC section 18.30.130 (high rise residential hotel/motel) or CA Energy Code section 150.1(c) 14 (low-rise residential) El Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher El Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors El Exception: fl For systems serving multiple dwelling units, install a central water-heating system with all of the following: El Gas or propane water heating system El Recirculation system per CIVIC 18.30.150(B) (high-rise residential, hotel/motel) or CIVIC 18.30.170(B) (low- rise residential) El Solar water heating system that is either: E1.20 solar savings fraction E]. 15 solar savings fraction, plus drain water heat recovery []Exception: B. R Nonresidential new construction Please refer to Carlsbad Ordinance CIVIC section 18.30.150 when completing this section. Water heating system derives at least 40% of its energy from one of the following (attach documentation): El Solar-thermal El Photovoltaics El Recovered energy []Water heating system is (choose one): Heat pump water heater D Electric resistance water heater(s) DSolar water heating system with .40 solar savings fraction 0 Exception: Updated 8/15/2019 4 - City of Carlsbad Climate Action Plan Consistency Checklist 1 4. Electric Vehicle Charging Residential New construction and major alterations* Please refer to Carlsbad Ordinance CIVIC section 18.21.140 when completing this section. IJOne and two-family residential dwelling or townhouse with attached garage: []One EVSE Ready parking space required U Exception:________________________________ fi Multi-family residential: U Exception:_________________________________ Total Parking Spaces Proposed EVSE Spaces Capable Ready Installed Total Calculations: Total EVSE spaces =10 x Total parking (rounded up to nearest whole number) EVSE Installed = Total EVSE Spaces x.50 (rounded up to nearest whole number) EVSE other= Total EVSE spaces - EVSE Installed (EVSE other may be "Capable," "Ready" or Installed.") *Major alterations are: (1) for one and two-family dwellings and townhouses with attached garages, alterations have a building permit valuation a $60,000 or include an electrical service panel upgrade; (2) for multifamily dwellings (three units or more without attached garages), aerations have a building permit valuation 2! $200,000, interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed. [] Nonresidential new construction (includes hotelsImotels) Exception: Total Parking Spaces EVSE So Installed Total 10 2 5 1 I 8 Calculation: Refer to the table below: Total Number of Parking Spaces provided Number of required EV Spaces Number of required EVSE Installed Spaces 0 0-9 1 0 10-25 2 0 26-50 4 2 51-75 6 3 o 76-100 9 5 101-150 12 6 IJ 151-200 17 9 201 and over 10 percent of total 50 percent of Required EV Spaces Updated 8/15/2019 5 City of Carlsbad Climate Action Plan Consistency Checklist 1 6. 0 Transportation Demand Management (TDM): Nonresidential ONLY I An approved Transportation Demand Management (TOM) Plan is required for all nonresidential projects that meet a threshold of employee-generated ADT. City staff will use the table below based on your submitted plans to determine whether or nor your permit requires a TDM plan. If TOM is applicable to your permit, staff will contact the applicant to develop a site-specific TDM plan based on the permit details. Employee ADT Estimation for Various Commercial Uses TI Use M1J . JJD Office __ ___ 20 13 11 11 Resturart 8 4.5 Retail3 Industrial___________________ 4 3.5 4 3 Manufacturing 4 1 Warehousing 1 Unless otherwise noted, rates estimated from ITE Trip Generation Manual, lOthEdition 2 For all office uses, use SANDAG rate of 20 ADT/1 ,000 Sf to calculate employee ADT Retail uses include shopping center, variety store, supermarket, gyms, pharmacy, etc. Other commercial uses may be subject to special consideration Sample calculations: Office: 20,450 Sf 1. 20,450 Sf/1000 x 20 = 409 Employee ADT Retail: 9,334 Sf First 1,000 sf= 8ADT 9,334 sf- 1,000 sf= 8,334sf (8,334 sf/1,000 x 4.5) + 8 = 46 Employee ADT Acknowledgment: I acknowledge that the plans submitted may be subject to the City of Casbad's Transportation Demand Management Ordinance. I agree to be contacted should my permit require a TOM plan and understand that an approved TOM plan is a condition of permit issuance. Applicant Signature: Date: 06.15.2020 Person other than Applicant to be contacted for TDM compliance (if applicable): Name (Printed): Heather Moore Phone Number: 619-569-5633 EmailAddress: hmoore@waremalcomb.com Updated 8/15/2019