HomeMy WebLinkAbout2099 TRUESDELL LN; ; CB080672; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 06-23-2008 . . . ' Residential Permit Permit No: CB080672 Building Inspection Request Line (760) 602-725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 2099 TRUESDELL LN CBAD RESDNTL Sub Type: RAD 1671801800 Lot #: 0 $156,284.00 Construction Type: VN Reference #: 0 . Structure Type: O Bathrooms: 0 SIMPKINS: ADD 400SF NEW&20285F REMODELED Status: ISSUED Applied: 04/15/2008 Entered By: JMA Plan Approved: 06/23/2008 Issued: 06/23/2008 Inspect Area: Orig PC#: Plan Check#: Applicant: Owner: LARS CONSTRUCTION SIMPKINS DONALD&KATHLEEN FAMILY TRUST 12-26-07 4715 60TH ST 6512 CAMINO DEL PARQUE SAN DIEGO CA 91941 CARLSBAD CA 92011 619 470-8940 Building Permit $787.77 Meter Size Add'I Building Permit Fee $0.00 Add'I Red. Water Con. Fee $0.00 Plan Check $512.05 Meter Fee $0.00 Add'I Plan Check Fee $0.00 SDCWA Fee $0.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $15.63 PFF (3105540) $0.00 Park in Lieu Fee $0.00 PFF (4305540) $0.00 Park Fee $0.00 License Tax (3104193) $0.00 LFM Fee $0.00 License Tax (4304193) $0.00 Bridge Fee $0.00 Traffic Impact Fee (3105541) $0.00 Other Bridge Fee $0.00 Traffic Impact Fee (4305541) $0.00 BTD #2 Fee $0.00 Sidewalk Fee $0.00 BTD #3 Fee $0.00 PLUMBING TOTAL $48.00 Renewal Fee $0.00 ELECTRICAL TOTAL $20.00 Add'I Renewal Fee $0.00 MECHANICAL TOTAL $43.50 Other Building Fee $0.00 Housing Impact Fee $0.00 HMP Fee $0.00 Housing lnLieu Fee $0.00 Pot. Water Con. Fee $0.00 Housing Credit Fee $0.00 Meter Size Master Drainage Fee $0.00 Add'I Pot. Water Con. Fee $0.00 Sewer Fee $0.00 Red. Water Con. Fee $0.00 Additional Fees $0.00 TOTAL PERMIT FEES $1,426.95 Total Fees: $1,426.95 Total Payments To Date: $1,426.95 Balance Due: $0.00 FINA ____ Inspector: Date: V I Cleaiance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations;or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will be. any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any City of Carlsbad 1635 Faraday Ave., Carlsbad, CA 92008 760-60-2717, / 2718 / 2719 Fax: 760602-8558 Building Permit Application Plan Check No. Est. Value Plan Ck. Deposit JOB ADDRESS QO'/ 17io/aL i1-p SUITE#/SPACE#/UNIT# APN / - 90 - '' - Oo CT/PROJECT # LOT U PHASE U U OF UNITS U BEDROOMS U B ATHROOMS TENANT BUSINESS NAME CON TR PE 0CC GROUP DESCRIPTION OF WORK: yopcsa(.. o aMi'i iiv rodQJ .tr nAR-oo ri_. . EXIST 0 USE- ___________________ ED USE - PR 6aka& .J GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE YES 0 #_ NOD. AIR CONDITIONING YES 0 NOD FIRE SPRINKLERS YES 0 NOD CONTACT~ 117 ZTME ADDR CI Qç cliv . STATE aK ZIP FA O4/ : 7 FAX PROPERTY OWNqRPAME CONTRACTOR BUS. ADDRESS 2o4 Ln . ADDRESS L p3 )flj Cl STATE ZIP . &. . . CITY .STATI/ ZIP. .910a_ . PH FAX ., . PYONE- FAX i2)2 EMAIL . . . ., E (3 (p3t ARCH/DESIGNER NAME & ADDRESS STATE LIC. U STATE t.IC U . CLASS 16 C B . LIC.0 rc7 n (sec. 1031.5 Butini:. and Professions Code: Any City or Connly Chick requires a permit to construct, alter improve 4e,molish or repair any structure inrco its issuance. ts9 requires eke applicant for such permit ti)ii signed sternent that is licensed jilirsoant to the provisions of the Cttracor's License law (Chapter 9. commending with Section /000 of Dwismoo 3 of tht Boniness and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. tiny violation of Section t03I.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than live hundred dollars {$500}) . Workers' Compensation Declaration: thereby affirm under penally of perjury one of the following declaiations: . . 0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 370001 the Labor Code, for the performance of the work for which this permit is issued. have and will maintain works 'compensation, as required by S lion 370oft Labor Code, or the performance th r.k for which this pe ii issued. My workers' compensation insurance rand policy number are: Insurance Co. ..41L.1 4! 60 1A olicy No. _%S:'-()__( C),Ti/ Expiration Date / This section need not be completed if the permit is L one hundred dollars (1Q6) or lass: . . . . . . . 0 Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation laws of California. WARNING: Failure tosecure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), In addition to the cost of compensation, damages as provided for In Section 370601 the Labor code, Interest and attorney's fees. CONTRACTOR SIGNATURE . ., . DATE (f. /5'cc' I hereby affirm that lam exempt from Contractor's Ucense Law for the following reason: . . Cl I. as owner of the properly or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business .and Professions Code: The Contractor's License Law does not apply loan owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). CI I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply loan owner of properly who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 I am exempt under Section Business and Professions 'Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement 0 Yes 0 No 2.1 (have! have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name address! phone! contractors' license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name! address phone contractors' license number): I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name! address ! phone type of work): .'PROPERTY OWNER SIGNATURE .' . DATE it?c Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Cl Yes 0 No . Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 Yes 0 No . Is the facility 16 be constructed within 1.000 feet of the outer boundary of a school site? DYes 0 No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lende?s Address 04 IO10® I certifythatl have madiheapplication and state thatthe above information iscorrectand thatthe information on the plans isaccurate. I agree tocomptywith all Cityotdinancesand State laws relatingtobulldingconstnuction. Ihereby authorize representative of the City of Carlsbad to enter upon the above mentioned propeity for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 50' deep and demolition orconstmuction of structures over 3 stories in height EXPIRATION: Every pemlit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is nOt commenbod within 180 days from the date of such permit orif the buildin rwomlc a nzed bysuch peànitis suspended or abandoned at any time after the work is commenced for a period of l8O days (Section 106.4.4 Uniform Building Code). £'APPLICANT'S . ' DATE . . / City of Carlsbad Bldg Inspection Request For: 09/22/2009 Permit# CB080672 Title: SIMPKINS: ADD 400SF NEW&2028SF Description: REMODELED Type: RESDNTL Sub Type: RAD Job Address: 2099 TRUESDELL LN Inspector Assignment: PC Phone: Suite: Lot: 0 Location: Inspector: OWNER SIMPKINS DONALD&KATHLEEN FAMILY TRUST 12-26-07 Owner: SIMPKINS DONALD&KATHLEEN FAMILY TRUST 12-26-07 Remarks: no recall on final. Corrections made? Total Time: CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Act omments Requested By: CHRISTINE Entered By: CHRISTINE Comments/Notices/Holds Associated PCRs/CVs Original PC# Inspection History Date Description Act lnsp Comments 03/18/2009 89 Final Combo CO PC ALL OK EXCEPT INSTALL YARD BOX ON FRONT CLEANOUT AND APPRV C.O. CAP. 03/18/2009 98 BMP Inspection AP PC BMP NOT REQD. ALL LANDSCAPE IN PLACE 01/14/2009 17 Interior Lath/Drywall AP PY GARAGE ONLY 11/18/2008 27 Shower Pan/Roman Tubs AP PC 11/17/2008 27 Shower Pan/Roman Tubs CA PC 10/29/2008 17 Interior Lath/Drywall AP PC 10/29/2008 18 Exterior Lath/Drywall AP PC 10/22/2008 16 Insulation AP PD 10/20/2008 14 Frame/Steel/Bolting/Welding AP PC 10/20/2008 34 Rough Electric CO PC see card on site 10/20/2008 44 Rough/Ducts/Dampers AP PC 10/16/2008 14 Frame/Steel/Bolting/Welding CA PC Inspection List Permit#: CB080672 Type: RESDNTL RAD SIMPKINS: ADD 400SF NEW&2028SF REMODELED Date Inspection Item Inspector Act Comments 09/22/2009 89 Final Combo PC AP 09/22/2009 89 Final Combo - RI no recall on final. Corrections made? 03/18/2009 89 Final Combo PC CO ALL OK EXCEPT INSTALL YARD BOX ON FRONT CLEANOUT AND APPRV CO. CAP. 03/18/2009 98 BMP Inspection PC AP BMP NOT REQD. ALL LANDSCAPE IN PLACE 01/14/2009 17 Interior Lath/Drywall PY AP GARAGE ONLY 11/18/2008 27 Shower Pan/Roman Tubs PC AP 11/17/2008 27 Shower Pan/Roman Tubs. PC CA 10/29/2008 17 Interior Lath/Drywall PC AP 10/29/2008 18 Exterior Lath/Drywall PC AP 10/22/2008 16 Insulation PD AP 10/20/2008 14 Frame/Steel/Bolting/Weldin PC AP 10/20/2008 34 Rough Electric PC CO see card on site 10/20/2008 44 Rough/Ducts/Dampers PC AP 10/16/2008 14 Frame/Steel/Bolting/Weldin PC. CA 10/14/2008 13 Shear Panels/HD's PC AP 10/14/2008 14 Frame/Steel/Bolting/Weldin PC WC 09/17/2008 21 Underground/Under Floor PC AP 09/1712008 22 Sewer/Water Service PC AP 09/17/2008 24 Rough/Topout PC AP 09/16/2008 21 Underground/Under Floor PC CO NO TOP OUT TEST 09/16/2008 24 Rough/Topout PC CO 09/03/2008 15 RooflReroof PC AP 08/08/2008 11 Ftg/Foundation/Piers PC AP 08/01/2008 11 Ftg/Foundation/Piers PC CA PLN REVISIONS NEEDED 07/29/2008 11 Ftg/Foundation/Piers PC AP 07/25/2008 21 Underground/Under Floor PC AP IV Tuesday, September 22, 2009 Page 1 of 1 Carlsbad 080672 6/9/08 . EsGil_Corporation In Partnership With Govemmentfor BuiWing Safety DATE: 6/9/08 JURISDICTION: Carlsbad PLAN CHECK NO.: 080672 PROJECT ADDRESS: 2099 Truesdell Lane SET:IU t22tI6AT COJURIS. 0 PLAN REVIEWER 0 FILE PROJECT NAME: Simpkins Residence Addition and Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. PLEASE SEE REMARKS BELOW LI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Date contacted: (by: ) Mail Telephone Fax In Person REMARKS: Please place City soils stamp on the plans. By: Tamara Fischer Enclosures: Esgil Corporation U GA 0 MB 0 EJ 0 PC 6/2/08 C!rlsbad 080672 5/16/08 EGiI_Corporation In Partnership wit/i government for Building Safety DATE: 5/16/08 JURISDICTION: Carlsbad PLAN CHECK NO.: 080672 PROJECT ADDRESS: 2099 Truesdell Lane SET: II 13 AMc13 UR$. U PLAN REVIEWER U FILE PROJECT NAME: Simpkins Residence Addition and Remodel Eli The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. Lii The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Terry Montello 4715 60th St., San Diego, CA 92115 LI Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed: Person contacted: Terry Montello Date contacted: "" (by:1y) Mail ._—Telephone Fax" In Person LI REMARKS: By: Tamara Fischer Esgil Corporation 0 GA 0 MB lJ EJ 0 PC 5/15/08 Telephone #: 619 994-5557 Fax #:619 229-0642 Enclosures: Carlsbad 080672 5/16/08 Please make all corrections, as requested in the correction list. Submit three new complete sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602- 2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. NOTE: The items listed below are from the previous correction list. These items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold are current. PLEASE NOTE: SITE PLAN NOW SHOWS A POOL. SPECIFY THAT IT IS NOT A PART OF THIS PERMIT. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). Current sets are signed. This will be verified on final sets. Plans deviating from conventional wood frame construction shall have the structural portions signed and sealed by the California state licensed engineer or architect responsible for their preparation, along with structural calculations.. (California Business and Professions Code). Applies only if calculations are required due to #12 below. 10. Truss submitted does not match the plans (plans state 3:12 slope, while truss is 4:12 slope and floor plan states scissor trusses with internal ridge line, while truss submitted is a standard truss). Please coordinate. It appears the longer spanning truss is T2. Ti is shown on the framing plan. Also the truss identification number for the shorter span trusses needs to be shown on the framing plan. 12. Several interior walls are being removed. Are these bearing walls or shear walls? If they are not, please specify this on the plans. If they are shear walls or bearing walls, please provide a design by a California State licensed engineer or architect with calculations showing how these elements will be replaced. The question of whether these interior walls being removed are shear walls was not answered. Note on sheet 4 is to verify they are not bearing walls. Carlsbad 080672 5/16/08 Because openings are being added in the existing rear wall of the house, it must be shown that the entire wall line meets the bracing requirements for conventional construction unless lateral calculations are provided. Per table 2308.12.4, this would require 9'4" of plywood shear wall in each 25' (this building is in seismic design category D with an SDS of .829). The total length of this wall is 60', therefore 22 1/2 'of plywood shear wall would be required in this line with a maximum 25' spacing of panels and a panel located within 8' of each end of the wall. This may require an alternate braced panel per section 2308.9.3.1 at the west end as the plate height is 8' and the wall between the sliding glass door and the end is less than 4' wide. The plans show 18' of shear wall along this line. 22.5' is required as explained above. Please provide evidence that the engineer-of-record (or architect) has reviewed the truss calculation package prepared by others (i.e., a "review" stamp on the truss calculations or a letter). Section A106.3.4.1. (Applies only if a licensed engineer or architect is retained due to # 12 above). 16. The following design loads shall be clearly indicated on the construction documents. (Section 1603.1) PLEASE NOTE: THOSE ITEMS WITH A *** MAY BE OMITTED IF NO CALCULATIONS ARE REQUIRED Starred items from the previous list will be required if calculations are required due to # 12 above. Otherwise just provide the wind exposure. Wind load. The following information should be provided, (Section 1603.1 .4) a) Wind exposure Special inspection for seismic resistance shall be noted on the plans for the following conditions in accordance with Section 1707. This will apply to shear walls with 4" nail spacing or less. I don't see this specified. Seismic Desian I inspection required C, D, E, and F • Structural wood*, structural welding, and cold form steel framing in "seismic-force-resisting systems" ** * Special inspection is not required for wood where the fastener spacing of the sheathing is more than 4" on center. ** The part of the structural system that has been considered in the design to provide the required resistance to the prescribed seismic forces. (Section 1613.1) A Statement of Special Inspections, prepared by the design professional in responsible charge, shall be submitted. This statement shall include a complete list of materials and work requiring special inspection, the inspections to be performed and an indication whether the special inspection will be continuous or Carlsbad 080672 5/16/08, periodic. Section 1705.2. See # 17 Show on the plans that countertop receptacle outlets comply with CEC Article 210.52(C): In kitchens a receptacle outlet shall be installed at each counter space 12 inches or wider; Receptacles shall be installed so that no point along the wall line is more than 24 inches; Island and peninsular countertops 12 inches by 24" long (or greater) shall have at least one receptacle. (Counter top spaces separated by range tops, refrigerators, or sinks shall be considered as separate counter top spaces.) More are needed to make kitchen comply. Still need one to the right of kitchen sink. Show at least one wall switch-controlled lighting outlet to be installed in every habitable room. CEC Article 210.70(A); Dining room. Not shown for the dining room. If the water heater is new, specify its size in BTU per hour and verify existing gas pipe sizing is adequate for the increased demand. The l/4" line is inadequate. Provide a gas piping layout for the whole house. 28. Show on the plans compliance with the residential energy lighting requirements (Mandatory requirement): b) Outdoor lighting fixtures are required to be high efficacy or controlled by a combination photocontrol/motion sensor. Note sheet 3 states photo control or motion sensor. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes U No E3 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Tamara Fischer at Esgil Corporation. Thank you. . . EsGil Corporation In !Partnership with government for BuiWing Safety DATE: 4/24/08 JURISDICTION: Carlsbad PLAN CHECK NO.: 080672 SET: I PROJECT ADDRESS: 2099 Truesdell Lane PROJECT NAME: Simpkins Residence Addition and Remodel NT U JUR U PLAN REVIEWER U FILE El The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. JIIJ The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. Li The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. Li The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Terry Montello 4715 60 th St., San Diego, CA 92115 LI Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: TeryMpntello Telephone #: 619 994-5557 Date contacted '4570Yy?M) Fax #: 619 229-0642 Mail Telephone Fax Person Li REMARKS: By: Tamara Fischer Enclosures: Esgil Corporation 0 GA 0 MB 0 EJ 0 PC 4/17/08 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 080672 4/24/08 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: 080672 JURISDICTION: Carlsbad PROJECT ADDRESS: 2099 Truesdell Lane FLOOR AREA: 400 sq ft SFD Add 2028 sq ft Remodel REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 4/24/08 STORIES: 1 HEIGHT: 12' approx per IBC DATE PLANS RECEIVED BY ESGIL CORPORATION: 4/17/08 PLAN REVIEWER: Tamara Fischer FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2007 edition of the California Building Code (Title 24), which adopts the following model codes: 2006 IBC, 2006 UPC, 2006 UMC and 2005 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2006 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad 080672 4/24/08 Please make all corrections, as requested in the correction list. Submit three new complete sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602- 2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. Indicate on the Title Sheet of the plans the name of the legal owner and name of the person responsible for the preparation of the plans. Sec. A106.1.1. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). Plans deviating from conventional wood frame construction shall have the structural portions signed and sealed by the California state licensed engineer or architect responsible for their preparation, along with structural calculations.. (California Business and Professions Code). If applicable. Please revise the section numbers and notes on the plans to match the 2006 IBC, as adopted by California. For example, seismic information and roof live load in the design information box on sheet 1, code section at door note B, sheet 3 is from the previous code, electrical notes, sheet 3 reference the UBC, etc. Please check all and revise. Where an addition, alteration or repair to an individual dwelling unit or guestroom in Group R requires a permit, battery-operated smoke alarms shall be installed in the existing construction in accordance with the following. Show locations of smoke alarms (Section 907.2.10.1.2 Section 907.2.10.5.2.): a) On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms. At least 1/2 of the common wall must be open and have an opening not less than 25 sq. ft., nor 10% of the floor area of the interior room (8% for ventilation), if light and ventilation is being supplied from an adjacent room. Sections 1203.4.1.1 and 1205.2.1. It does not appear that kitchen/living wall is 50% open and kitchen has no windows. Please provide an interior elevation of this wall. If mechanical ventilation is to be used, it must be a whole house system with a 4" outside air duct. Carlsbad 080672 4/24/08- Show location of attic access with a minimum size of 22"x30", unless the maximum vertical headroom height in the attic is less than 30 inches. Access must be provided to each separated attic area. Section 1209.2. If tankless water heater is new, show that it will be mounted high enough to be out of the path of vehicles. (This should also take care of the requirement for the flame to be minimum 18" above the floor). CPC Section 508.14 Note on plans that surface water will drain away from building and show drainage pattern. The grade shall fall a minimum of 5% within the first 10 feet (2% for impervious surfaces). Section 1803.3. Truss submitted does not match the plans (plans state 3:12 slope, while truss is 4:12 slope and floor plan states scissor trusses with internal ridge line, while truss submitted is a standard truss). Please coordinate. Sill plate size and anchorage. Anchor bolts shall be provided with square washers in accordance with Section 2305.3.11. Show the 3" square X 0.229" plate on the plans. This also applies to the existing walls being retrofitted as shear walls. Please detail retrofitted plate anchorage at these locations. Several interior walls are being removed. Are these bearing walls or shear walls? If they are not, please specify this on the plans. If they are shear walls or bearing walls, please provide a design by a California State licensed engineer or architect with calculations showing how these elements will be replaced. Because openings are being added in the existing rear wall of the house, it must be shown that the entire wall line meets the bracing requirements for conventional construction unless lateral calculations are provided. Per table 2308.12.4, this would require 9'4" of plywood shear wall in each 25' (this building is in seismic design category D with an SDS of .829). The total length of this wall• is 60', therefore 22 ½ 'of plywood shear wall would be required in this line with a maximum 25' spacing of panels and a panel located within 8' of each end of the wall. This may require an alternate braced panel per section 2308.9.3.1 at the west end as the plate height is 8' and the wall between the sliding glass door and the end is less than 4' wide. Please provide a braced panel at the infilled wall at the south wall of bedroom 1. Please provide evidence that the engineer-of-record (or architect) has reviewed the truss calculation package prepared by others (i.e., a "review" stamp on the truss calculations or a letter). Section Al 06.3.4.1. (If a licensed engineer or architect is retained due to any of the above corrections). Carlsbad 080672 4/24/08 16. The following design loads shall be clearly indicated on the construction documents. (Section 1603.1) PLEASE NOTE: THOSE ITEMS WITH A *** MAY BE OMITTED IF NO CALCULATIONS ARE REQUIRED Roof live load. Each roof live load used should be indicated. Should be 20 psf (16 psf is shown on sheet 1). Wind load. The following information should be provided, (Section 1603.1.4) Basic Wind speed (3-second gust), mph (85MPH) Wind importance factor, I, and building category Wind exposure Seismic design data. The following information should be provided. (Section 1603.1.5) Seismic importance factor, lE and occupancy category*** Mapped spectral response accelerations Ss and S1 Site class (D) Spectral response coefficients SDS and Sol*** Seismic design category (D) Basic seismic-force-resisting system(s) Design base shear Seismic response coefficient(s), C5 Response modification factor(s), R Analysis procedure used. 17. Special inspection for 'seismic resistance shall be noted on the plans for the following conditions in accordance with Section 1707. This will apply to shear walls with 4" nail spacing or less. Seismic Design Ca Special inspection required C, D, E, and F • Structural wood*, structural welding, and cold form steel framing in "seismic-force-resisting systems"** * Special inspection is not required for wood where the fastener spacing of the sheathing is more than 4" on center. ** The part of the structural system that has been considered in the design to provide thern required resistance to the prescribed seismic forces. (Section 1613.1) Carlsbad. 080672 4/24/08 A Statement of Special Inspections, prepared by the design professional in responsible charge, shall be submitted. This statement shall include a complete list of materials and work requiring special inspection, the inspections to be performed and an indication whether the special inspection will be continuous or periodic. Section 1705.2. All chimneys attached to any appliance or fireplace that burns solid fuel shall be equipped with an approved spark arrester. The net free area of the spark arrester shall be not less than four times the net free area of the outlet of the chimney. The spark arrester screen shall have heat and corrosion resistance equivalent to twelve gauge wire, nineteen gauge galvanized wire or twenty-four gauge stainless steel. Openings shall not permit the passage of spheres having a diameter larger than one-half inch and shall not block the passage of spheres having a diameter of less than three-eight inch. City ordinance. Please specify bold information on the plans. Show on the plan the amperage of the electrical service,the location of the service panel and the location of any sub-panels. If the service is over 200 amperes, submit a single line diagram, panel schedules, and provide service load calculations. Show on the plans that receptacle outlet locations will comply with CEC Article 210.52(A). Show compliance for all rooms where walls are being altered. (Openings filled in or added or new walls constructed). Show on the plans that countertop receptacle outlets comply with CEC Article 210.52(C): In kitchens a receptacle outlet shall be installed at each counter space 12 inches or wider; Receptacles shall be installed so that no point along the wall line is more than 24 inches; Island and peninsular countertops 12 inches by 24" long (or greater) shall have at least one receptacle. (Counter top spaces separated by range tops, refrigerators, or sinks shall be considered as separate counter top spaces.) More are needed to make kitchen comply. Show at least one wall switch-controlled lighting outlet to be installed in every habitable room. CEC Article 210.70(A). Dining room. If the water heater is new, specify its size in BTU per hour and verify existing gas pipe sizing is adequate for the increased demand. Show the T and P relief valve at the water heater and the discharge pipe size and routing to the exterior. CPC Section 608.3. If new. For gas piping under slabs that serve kitchen island cooktops, see Policy 91-46 (attached) for special sleeve and clean-out requirements. Please specify all infilled exterior walls to have minimum Ri 3 insulation. Carlsbad 080672 4/24/08 28. Show on the plans compliance with the residential energy lighting requirements (Mandatory requirement): In bathrooms, all fixtures must be high efficacy style or be controlled by a manually-on occupancy sensor. Dimmers Cannot be used to satisfy this. Outdoor lighting fixtures are required to be high efficacy or controlled by a combination photocontrol/motion sensor. Note sheet 3 states photo control or motion sensor. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes D No The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Tamara Fischer at Esgil Corporation. Thank you. • CITY OF CARLSBAD POLICIES AND PROCEDURES 4UMBER: 91-46 SUBJECT: Gas Piping - Island Kitchen Cooktop EFFECTIVE: 5/24/91 SECTION: BUILDING DEPARTMENT 3UPERSEDES: URPOSE: To establish an approved method for gas piping to an island cooktop. OLICY: The drawing shown below is approved for this use. NOTES: 1. ALLSLEEVES TO BE SCH. LO ABS GAS PIPING BELOW SLAB TO BE FACTORY WRAPPED EXCEPT FITTINGS MAY BE PRIMED AND FIELD WRAPPED ALL UNDERGROUND PIPING TO BE INSTALLED AT THE TIME OF UNDERGROUND PIPING INSPECTION GAS PIPING SCREENED----%— APPRO 1 MIN. VED SEALANT VENT 211 SAN, TEE OPENING 311 ABS ' 211 ABS RISER' RISER_!,. :' .L. 3IIX2It SER' RI S ER .14 L% . ___ ____ 3tI ABS IXTERIOR :- • TEE SLOPE UP TO 3"CLEAN OUT Initiated By: Approved By: Carlsbad 080.672 4/24/08. VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 080672 PREPARED BY: Tamara Fischer DATE: 4/24/08 BUILDING ADDRESS: 2099 Truesdell Lane BUILDING OCCUPANCY: R3 / U TYPE OF CONSTRUCTION: VB BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) SFD ADD 400 121.94 48,776 Remodel 2028 53.00 107,484 Air Conditioning Fire Sprinklers TOTAL VALUE 156,260 Jurisdiction Code 1cb IBY Ordinance Bldg. Permit Fee by I $787.771 Plan Check Fee by Ordinance I $512.05 Type of Review: El Complete Review LI Structural Only 0 Other El Repetitive Fee Repeats Hourly J Hour * Esgil !Ian Review Fee $441.151 Comments: Sheet 1 of 1 macvalue.doc 1. I. City of Carlsbad 9r 1:II1.I 'A'IT1 -_ it. ii .ti aIi1j BUILDING PLANCHECK CHECKLIST DATE: ____ PLANCHECK NO.: CB 70 BUILDING AE/DRSS: PROJECT DESCRIPTION: ASSESSOR'S PARCEL NUMBER: &!Z- /O - EST. VALUE: ENGINEERING DEPARTMENT APPROVAL DENIAL The item you have submitted for review has been Please see t attached report of deficiencies approved. The approval is based on plans, marked with . Make necessary corrections to plans information and/or specifications provided in your or specif t ns for compliance with applicable submittal; therefore any changes to these items after codes and Stan ards. Submit corrected plans and/or this date, including field modifications, must be specifications to this office forreview. reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. y: Date: 0 A Right-of-Way permit is required prior to construction of the following improvements: . Date: Date: NGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT: By: __'SEZ!__....____- Date: AACHMENTS ENGINEERING DEPT. CONTACT PERSON Dedication Application Name: JOANNE JUCHNIEWICZ El Dedication Checklist City of Carlsbad 0 Improvement Application Address: 1635 Faraday Avenue, Carlsbad, CA 92008 Improvement Checklist Phone: (760) 602-2775 0 Neighborhood Improvement Agreement D Grading Permit Application 0 Grading Submittal Checklist 0 Right-of-Way Permit Application E] Right-of-Way Permit Submittal Checklist and Information Sheet 0 Storm water Applicability Checklist CFD INFORMATION Parcel Map No: Lots: Recordation: Carlsbad Tract: Carlsbad, CA 920W-7314 • (760) 602-2720 • FAX (760) 6021 52 HS - '1 pp. BUILDING PLANCHECK CHECKLIST 5$',Z.o ('tè r SITE PLAN - 1. Provide a fully dimensioned site plan drawn to scale. Show: Right-of-Way Width & Adjacent Streets Driveway widths Existing or proposed sewer lateral Existing or proposed water service Existing or proposed irrigation service A. North Arrow __5 c1' Existing & Proposed Structures t- c,a\ C. Existing Street Improvements / D. Property Lines / E. Easements j$\ JLJ D 2. Show on site plan: (G Drainage Patterns Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive B. drainage of 2% to swale 5' away from building," Existing & Proposed Slopes and Topography -54s"i C(7J Size, type, location, alignment of existing or proposed sewer and water service (s) that serves the project. Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception. D. Sewer and water laterals should not be located within proposed driveways, per standards. 0 0 3. Include on title sheet: Site address Assessor's Parcel Number Legal Description . For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION F:8UII.DINO PLANCHECK CKLST FORM.doc 2 . . Rev. 7II4OO BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD DISCRETIONARY APPROVAL COMPLIANCE El 0 4a. Project does not comply with the following Engineering Conditions of approval for I Project No._________________________________________________________ El El El 4b. All conditions are in compliance.. Date: DEDICATION REQUIREMENTS El 0 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ 17,000 , pursuant to Carlsbad Municipal Code Section 18.40.030. Dedication required as follows: Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 W x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form .with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completed by: Date: IMPROVEMENT REQUIREMENTS. 0 El El 6a. All needed public improvements upon'* and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ 82,000 , pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required as follows: Attached please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on the F:BULLDING PI.ANCHECK CKLST FORM.dc Rev. 7114100 71 BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD checklist must be submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit. Improvement Plans signed by: . Date:..__________ 0 El El 6b. Construction of the public improvements may be. deferred .pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $430 so we may prepare the necessary Neighborhood Improvement Agreement.. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit. . . Future public improvements required as follows: El El 0 6c. Enclosed please find your Neighborhood Improvement Agreement. Please return agreement signed and notarized to the Engineering Department. /E3 Neighborhood Improvement Agreement completed by: Date: El 6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adiacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. . GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 15.16.010 of the Municipal Code. 0 0 0 7a. Inadequate information available on Site Plan to make 'a determination on grading requirements. Include accurate grading quantities in cubic yards (cut, fill, import, export and remedial). This information must be included on the plans. 0 0 0 7b. Grading Permit required. A separate grading plan prepared by a registered civil Engineer must be submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by: • . • Date: El El 0 . 7c. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) . F.-BUILDING PLANCHECKCKLST FORMA= 4 . Rev. 7114100 BUILDING PLANCHECK CHECKLIST 7d .No Grading Permit required. 1ST 2ND RD 7e. If grading is not required, write "No Grading" on plot plan. MISCELLANEOUS PERMITS (dJJ El El 8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. Right-of-Way permit required for: El 0 9. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List. You may telephone (760) 438-2722, extension 7138, for assistance. Industrial Waste permit accepted by; . Date: • • • • El 0 0 10. NPDES PERMIT ( Complies with the City's requirements of the National Pollutant Discharge Elimination System. (NPDES) permit.- The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas. Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occursfirst. . • ....• 1 :.;no STORM WATER APPLICABILITY CHECKLIST f'Requires PSWP (project storm water permit): # Not required 080 0 • 11 FEES o 5eired fees are attached , 7No fees required F:UILDING PLANCHECK CKLST FORM.doc 5 • Rev. 7114100 BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD WATER METER REVIEW D U U 12a. Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized. Oversized meters are inaccurate during low-flow conditions. If it is oversized, for the life of the meter, the City will not accurately bill the owner for the water used. All single family dwelling units received "standard" 1" service with 5/8" service. If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm). A typical fixture count and water demand worksheet is attaáhed. Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit. Maximum service and meter size is a 2" service with a 2" meter. If a developer is proposing a meter greater than 2", suggest. the installation of multiple 2" services as needed to provide the anticipated demand. (manifolds are considered on case by case basis to limit multiple trenching into the street). U U U 12b. Irrigation Use (where recycled water is not available) All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval. The developer must provide these calculations. Please follow these guidelines: If the project is a newer development (newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets. If so, at the water meter station, the demand in gpm may be listed there. Irrigation services are listed with a circled "I", and potable water is typically a circled "W". The irrigation service should look like: STA 1+00 Install 2" service and 1.5: meter (estimated 100 gpm) 2. If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (wl a right of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach). Typically, Larry Black has already reviewed this if landscape plans have been prepared, but the applicant must provide the calculations to you for your use. Once you have received a good example of irrigation calculations, keep a set for your reference. In general the calculations will include: Hydraulic grade line Elevation at point of connection (POC) Pressure at POC in pounds per square inch (PSI) Worse case zone (largest, farthest away from valve Total Sprinkler heads listed (with gpm use per head) Include a 10% residual pressure at point of connection F:BUILDING PI.ANCHECK CKI.ST FORMA= 6 Rev. 7114100 w 1ST 2ND 3RD BUILDING PLANCHECK CHECKLIST 3. In general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with .no HOA). As long as the project is located within the City recycled water service boundary,.the City intends on switching these irrigation services/meters to a new recycled water line in the future. 0 12c. Irrigation Use (where recycled water is available) Recycled water meters are sized the same as the irrigation meter above. If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development. For subdivisions, this should have been identified, and implemented on the improvement plans. Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees. However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge. If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund. However, let the applicant know that we cannot guarantee the refund, and they must deal with the SDCWAforthis. 0 0 0 13. Additional Comments: F:BUILONG PL.ANCHECIC MST FORM.doc 7 • Rev. 7114i00 CITY OF CARLSBAD STANDARD FORM - TIER 1 STORM WATER POLLUTION PREVENTION PLAN STORM WATER COMPLIANCE CERTIFICATE / My project is not In a category of permit types exempt from the Construction SWPPP requirements My project is not located inside or within 200 feet of an environmentally sensitive area with a significant potential for contributing pollutants to nearby receiving waters by way of storm water runoff or non-storm water discharge(s). I My project does not requires a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 15.16 of the Carlsbad Municipal Code) / My project will not result in 2.500 square feet or more of soils disturbance Including any associated construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance areas that meets one or more of the additional following criteria: located within 200 feel of an environmentally sensitive area or the Pacific Ocean: and/or, disturbed area is located on a slope with a grade at or exceeding 5 horizontal to I vertical; and/or disturbed area is located along or within 30 feet of a storm drain inlet, an open drainage channel or watercourse; and/or construction will be initiated during the rainy season or will extend into the rainy season (Oct. 1 through April 30). I CERTIFY TO THE BEST OF MY KNOWLEDGE THAT ALL OF THE ABOVE CHECKED STATEMENTS ARE TRUE AND CORRECT. I AM SUBMITTING FOR Cliv APPROVAL A TIER 1 CONSTRUCTION SWPPP PREPARED IN ACCORDANCE WITH THE REQUIREMENTS OF CITY STANDARDS. I UNDERSTAND AND ACKNOWLEDGE THAT I MUST: (1) IMPLEMENT BEST MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION ACTIVITIES TO THE MAXIMUM EXTENT PRACTICABLE TO MINIMIZE THE MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO MINIMIZE THE EXPOSURE OF STORM WATER TO CONSTRUCTION RELATED POLLUTANTS; AND, (2) ADHERE TO, AND AT ALL TIMES, COMPLY WITH THIS CITY APPROVED TIER 1 CONSTRUCTION SWPPP THROUGHTOUT THE DURATION OF THE CONSTRUCTION ACTIVITIES UNTIL THE CONSTRUCTION WORK I COMPLETE AND OVED BY THE CITVA6F CAIILSMD. I.. C R • S'TiQEItl'ItA 7) DJ1 r)A Mb O41D W?,ER(StfOWNER *0514Th ( Oh ) DATE I. ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE AVAILABLE ON SITE TO FACILITATE RAPID INSTALLATION OF EROSION AND SEDIMENT CONTROL L3 1IF1DJial THE OWNER/CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN- OFF PRODUCING RAINFALL. THE OWNER/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEERING OR BUILDING INSPECTOR DUE TO UNCOMPLETED GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. ALL GRAVEL BAGS SHALL BE BURLAP TYPE WITH 3/4 INCH MINIMUM AGGREGATE. ADEQUATE EROSION AND SEDIMENT CONTROL AND PERIMETER PROTECTION BEST MANAGEMENT PRACTICE MEASURES MUST BE INSTALLED AND MAINTAINED. PROJECT INFORMATION SitcAddrcssiff True9el/ L Assessor's Parcel Number t(D1 l?b I ? Project ID: C,,P) o8,-i Construction Pamit No.J r S' I Estimated Construction Start Date Project Duration Months Emergency Contact: Name: 24 hour Phone: Perceived Threat to Storm Water Quality Medium w If medium box is checked, mliaw=4 a Site plan sheet showing proposed work area and location of proposed structural BMPs For City Use Only Erosion Control Waste SIMPS -_____ ___________________Non-Storm ater _________ Management SMPs Pollution Control BMPs Best Management Practice (BMP) Description 4 zConstruction Activity iHUUUUUUDIUUIUUUIUDDUUUUI dLZ.I' I .I -,,,I' -7 •. I • • • • • Instructions: Begin by reviewing the list of construction activities and checking the box to the left of any activity that will occur during the proposed construction. Add any other activity descriptions in the bionic activity description boxes provided for that purpose and places check in the box immediately to the left of the added activity description. For each activity descmbed, pick one or more best management practices (BMPs) from the list located alon the top of the form. Then place an X in the box at the place where the activity row intersects with the BMP column. Do this for each activity that was checked off and for each of the selected BMPs selected from the list. For Example - If the project includes site access across dirt, then check the box to the left of "Site Access Across Dirt". Then review the list for something that applies such as "Stabilized Construcion ingress/Egress" under Tracking Control. Follow along the "Site Access Across Dirt" row until you get to the "Stabilized Construction Ingress/Egress" column and place an X in the box where the two meet. As another example soy the project included a stockpile that you intend to cover with a plastic sheet. Since plastic sheeting is not on the list of BMPs, then write in "Cover with Plastic" in the blank column under the heading Erosion Control BMPs. Then place an X in the box where "Stockpiling" row intersects the new "Cover with Plastic" column. To learn more about what each BMP description means, you may wish to review the BMP Reference Handout prepared to assist applicants in the selection of appropriate Best Management Practice measures. The reference also explains the California Stormwater Quality Association (CASQA) designation and how to apply the various selected BMPs to a project. 4, PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST ( . Plan Check No. GB Q (0 712. Address Q.O q Truesdejl 1-31 19 Planner Chris Sexton Phone (760) 602-4624 APN:I7" I to "(S Type of Project & Use: dc1 i'I'IOYI Net Project Density: 1.0 DU/AC zoningR I General Plan: LFY Facilities Management Zone: I CFD (in/out) #_Date of participation: Remaining net dev acres:______ ! J (For ncn-residential development: Type of land used created by this Circle One permit: ) Legend: Item Complete Item Incomplete - Needs your action, EJ Fj Environmental Review Required: YES ___ NO ..JTYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: U U Discretionary Action Required: YES NO TYPE APPROVAL RESO. NO. DATE PROJECT. NO. OTHER RELATED CASES:.__________________________________________ Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval:__________________________________________________________ 0 0 Coastal Zone Assessment/Compliance Project site located in Coastal Zone? '(ES,_ NO4 CA Coastal Commission Authority? YES____ NO____ If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): 0 0 Habitat Management Plan Data Entry Completed? YES ____ NO r' If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (,AiPiDs, Activity Maintenance, enter CB#. toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE!) U U lnclusionary Housing Fee required: '(ES NO ,,' (Effective date of lnclusionary Housing Ordnance - May 21, 1993.) Data Entry Completed? YES . NO (AI P. Ds, Activity MaintGnncc-. eiTher C3 co!ar Screens, Housing Fees, Construct Housing Y. N, Enter Fee, UPDATE!) H:'ACiIIN'.COUNTEREI.qPIc;h!<PCkIt Re', 310(3 - Site Plan: -Provide a fully dimensional site plan dra'.',n to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topcgraphical lines (including all side and rear yard slopes). Provide legal description of property and assessor's parcel number. 0M Policy 44— Neighborhood Architectural Design Guidelines Applicability: YES NO________ Project complies YES NO________ Zoning: 1. Setbacks: Front: Required_' Shown Interior Side: Required £'$" Shown '?' Street Side: Required Shown _______________ Rear: Required 13' Shown Top of slope: Required Shown 2. Accessory structure setbacks: Front: Required Shown Interior Side: Required Shown Street Side: Required Shown Rear: Required Shown Structure separation: 3. Lot Coverage Required <hI/O 70 Shown UI.'. 4. Height: Required < 30 Shown '30 X 0 0 5. Parking: Spaces Required Shown 9 (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown 0 0 0 Additional Comments________________________________________________________ OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER I2Lt DATE/ S Rev 3.'