HomeMy WebLinkAbout2624 UNICORNIO ST; ; 86-334; Permit9 r- i hereby affirm that I am licensed under
U J provIsIon. of Chapter 9 (commencing with I Ssctton 7000) of Division 3 of the Business I and Professions Code, and my license Is In
L full force and effect.
I hereby affirm that I am exempt from the Contrac- tors License Law for the following reason (Sec. 7031.5
Business and Professions Code: Any city or county which re-
quires a permit to construct, alter, improve, demolish, or repair any structure, prior toils issuance also requires the ap-
plicant for such permit to tile a signed statement that he is licensed to the of the Contractor pursuant provisions
License Law (Chapter 9 commencing with Section 7000 at Division 3 of the Business and Professions Code) or that is ex-
empt therefrom and the basis for the alleged exemption. Any
violation at Section 7031,5 by an applicant for a permit sub'
iects the applicant too civil penally of not more than live hun-
dred dollars ($500).
11 I, as owner of the property, or my employees with wages
15 as their sole compensation, will do the work, and the struc-
ture is not Intended or offered for sale (Sec. 7044, Business ..a and Professions Code: The Contractor's License Law does
not apply Is an owner of property who builds or improves
thereon and who dues such work himself or through his own
employees, provided that such improvements are not intend-
91.1 ed or offered for sale. II, however, the building or improve- Z mont is sold within one year of completion, the owner-builder have the burden will of proving that he did not build or im-
prove for the purpose of sale),
O I, as owner 01 the property, am exclusively contracting
with licensed contractors to construct the project (Sec. 7044,
Business and Professions code: The Contractor's License
Law does not apply loan owner of property who builds or im-
proves thereon, and who contracts for each projects with a US coutractor(s) license pursuant to the Contractor's License Law).
0 As a homeowner tam improving my home, and the tallow- log conditions exist: t. The work is being performed prior to sale. I have lived in my home for twelve months
U prior to completion of this work.
Ml I have not claimed this exemption during the O last three years.
0 lam exempt under Sec. __________________ ,B & P.C. for this reason
1 hereby affirm that I have a certificate of consent Is
snllinsure. or a curtilicata of Workers' Compensation In.
surance, or a certified copy thereof (Sec. 3800. Labor Code]
POLICY NO.
COMPANY
0 Copy is filed with the city 0 Certified copy is hereby furnished
'a' B. 311 CERTIFICATE OF EXEMPTION FROM C.) WORKERS' COMPENSATION INSURANCE
I) (This section need not be completed if the permit
is for one hundred dollars ($100) or less) ul :19 0 I certify that in the performance of the work for which this permit is issued. I shall not employ any person in any
manner so auto become subject to the Workers' Compen
satlon Laws of California.
NOTICE TO APPLICANT: If, utter making this Certificate
of Exemption. you should become subject to the Workers
Compensation provisions of the Labor Code, you must
forthwith comply with such provisions or this permit shall
be deemed revoked.
U,
C 0) 0
0. 0,
C
tiEr RALI POINT PFN ONlY A PRFEE IIIARIN APPLICANT TO FILL IN INFORMATION WITHIN SHADED AREA AND DECLARATIONS.
or
f" 0 I hereby affirm that there Is a construction lendin
agency for the performance of the work for which this per
ol nit is Issued (Sec. 3097, Civil Cede) zi WI Lender's Name---- _J
L Lender's Address -
CARLSBAD BUILDING DEPARTMENT
-r
APPLICATION & PERMIT Carlsbad, California 92008-4859
ADDRESS - AV, ST. RD. NEAREST CROSS ST. . DA JF APP I TI BUSINESS LICENSE # VALUATION PERMIT NUMBER
/2 /1 LOT I BLOCK VBDI VISION I ASSESSOR PARCEL NO. OR -rtc Á
14 bNTRACTORSPHONE# ZONE -
crE 4JDtt.A
OWNER'S NAME ______________________________________ OWNER'S PHONE ________________________________________
CONTRACTOR'S ADDRESS STATE LICENSE NO. BUILDING SO. FOOTAGE
-
OWNER'S MAILING ADDRESS
ri ID 9 6r4 L P4 DESIGNER DESIGNER'S PHONE
OF WORK Z. -St' 5Qt4, 0 [DESCRIPTION
DESIGNER'S ADDRESS STATE LICENSE NO.
i I F/P FLR ELEV. NO 0CC GP-
JORIES (7LEAp YO NO ,e3 I/29/ao .riT 69i.i
12
- I -
.
PARKING SPACE E UNITS GRADING PERMIT ISSUED REDEVELOPMENT
AREA I d TYPE
ICONST
0CC LOAD FIR
- I '
17 I / N o - I vofl I I 2'4/ YO vO lSscj?Valid Unless Machine Certified
-
QTY. PLUMBING PERMIT ISSUE F QTY. MECHANICAL PERMIT- ISSUE ' NUMBER
EACH FIXTURE TRAP INSTALL FURN. DUCTS UP TO 100,000 BTU . — BUILDINPRM1T.,JJ
EACH BUILDING SEWER 100,000 BTU _OVER . SIGN PERMIT 001-8f6O0
_________________
EACH WATER HEATER AND/OR VENT 2 BOILER/COMPRESSOR UPTO3HP PLAN CHECK 001-810-00-00-8806 5"
EACH GAS SYSTEM I T04'OUTLETS BOILER/COMPRESSOR 3.15 HP , TOTAL PLUMBING 001-810-00'00'8222
EACH GAS SYSTEMS OR MORE , METAL FIREPLACE , ELECTRICAL 001-810-00-00-8223
EACH INSTAI.., ALTER. REPAIR WATER PIPE - VENT FAN SINGLE DUCT ."" MECHANICAL 001-810-00-00-8224 Ar
EACH VACUUM BREAKER
--=---.
,f'. j MECH EXHAUST - HOOD/DUCTS MOBILEHOME 001-810-00'00-8225
WATER SOFTNER . RELOCATION OF EA FURNACE/HEATER , SOLAR 001-810-00'00-8226
EACH ROOF DRAIN (INSIDE) - / DRYER VENT 'kr- STRONG MOTION 880-519-92'33 ___________
- TOTAL MECHANICAL
.
I FIRE SPRINKLERS 001-810'00-00-8227
- _________________ ______________________
TOTAL PLUMBING I PUBLIC FACILITIES FEE 320-810-00-00-8740
OTY. ELECTRICAL PERMIT- ISSUE 5' QTY. MOBILE HOME SETUP
BRIDGE FEE '3
PARK-IN-LIEU (AREA
NEW CONST EA AMPSWTBKR /a2 _____________
CAR PORT
_____________ TIF 001-810-00-00-8835
I PH 3 PH , AWNING . LICENE TAX 001-810-00-00-8162
EXIST BLDG EA AMP/SWT8KR GARAGE
I PH 3 PH
, ..'MFF/) 880-519-92-57 —
REMOOELALTER PER CIRCUIT
-
TEMP POLE 200 AMPS
OVER 200 AMPS
TEMP OCCUPANCY (30 DAYS)
CREDIT DEPOSIT <33-v —,
TOTAL ELECTRICAL
—
TOTAL
11 TOTAL FEES PAYABLE // IS —
I HAVE CAREFULLY EXAMINED THE COMPLETED "APPLICATION AND PERMIT" AND DO HEREBY I Expiration. Every permit issued by the Building Official under the provisions i,'tlris * AN OSHA PERMIT IS REQUIRED FOR EXCAVATIONS OVER
CERTIFY Ub1DER PENALTY OF PERJURY THAT ALL INFORMATION HEREON INCLUDING THE I Code shall expire by limitation and become null and void If the building Or wurk V111" DEEP AND DEMOLITION OR COdSTRUCTION OF I authorized by such permit Is not commenced within 180 days from the date of such STRUCfl,JRES OVER 3 STORIES IN HEIGHT DECLARATIONS ARE TRUE AND CORRECT AND I FURTHER CERTIFY AND AGREE IF A PERMIT IS permI, or if the building or work authorized by such permit is suspended or ISSUED: TO COMPLY WITH ALL CITY. COUN1Y AND STATE LAWS GOVERNING BUILDING CON I sb' nod at any time after twork is commenced bra period of 180 days ________________________________________________ STRUCTION. WHETHER SPECIFIED HEREIN OR NOT. I ALSO AGREE TO SAVE INDEMNIFY AND
KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES. JUDGMENTS, COSTS AND AP LI OWNE CONTRACTOR 0 APPRO ED BY
EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE
n A BY PHONE 0 . _______ GRANTING OF THIS PERMIT
4
0
TYPE I DATE I INSPECTOR
BUILDING - I
FOUNDATION
REINFORCED STEEL
MASONRY
GUNITE OR GROUT
SUB FRAME 0 FLOOR 0 CEILLING
SHEATHING 0 ROOF 0 SHEAR 'J/1/P
FRAME
EXTERIOR LATH /
INSULATION
INTERIOR LATH & DRYWALL
PLUMBING -
O SEWER AND BUCO 0 PJCO
UNDERGROUND 0 WASTE DiWATER 7//,t 4
TOP OUT 0 WASTE 0 WATER
TUB
_______
TUB AND SHOWER PAN
GAS TEST ,//pj 7'
O WATER HEATER 0 SOLAR W1ATER
ELECTRICAL
O ELECTRIC UNDERGROUND E1 UER
ROUGH ELECTRIC
O ELECTRIC SERVICE 0 TEMPORARY
O BONDING 0 POOL
MECHANICAL
0 DUCT & PLEM., 0 REF. PIF
HEAT - AIR COND. SYSTEMS
VENTILATING SYSTEMS
CALL FOR FINAL INSPEC
FINAL
PLUMBING
ELECTRICAL
MECHANICAL
GAS
BUILDING
SPECIAL CONDITIONS
I I
V WHEN ALL APPROPRIATE
BEEN APPROVED.
E
FIELD INSPECTION RECORD
REQUIRED SPECIAL INSPECTIONS INSPECTORS NOTES
INSPECTION
-
REO. IF
CHECKED
INSPECTOftS DATEAPPROVAL M,/<. Ate-
PRIOR TO
FOUNDATION INSP
SOILS COMPLIANCE
STRUCTURAL CONCRETE
OVER 2000 PSI
PRESTRESSED
CONCRETE
POST TENSIONED
CONCRETE
c
FIELD WELDING_
HIGH STRENGTH
BOLTS -.
SPEC IAL1ASONRv
PILES CAISSONS
I I I
"41
FINAL BUILDING INSPECTION .
PLAN CHECK NUMBER: DATE: 47
PROJECT NAME: . .
ADDRESS 224 tv
PROJECT NO.: - UNIT NUMBER: PHASE NO.:
TYPE OF UNIT: Af d V NUMBER OF UNITS:.
CONTACT PERSON: . . . .1
CONTACT TELEPHONE: . . . . .
' . .... . . .
~6S—
INSPECTED DATE
BY: "0000000 7 INSPECTED: APPROVED I APPROVED
INSPECTED - . - -.. DATE
BY: -_- INSPECTED: -. APPROVED DISAPPROVED
INSPECTED DATE . . .
BY: ._
.
INSPECTED: APPROVED ______ DISAPPROVED
COMMENTS:
S .
-V . . . . -.
V. •••:
S S S 5
I .
S • (.5 .
0.
Rev. 1188 WHITE Suspense BLUE Water District GREEN Engineering CANARY
UEs
PINK: Planning G LID: Fire
FINAL BUILDING INSPECTION
PLAN CHECK NUMBER 86-334 DATE 3-16-87
PROJECT NAME:
ADDRESS: 2624 ,UnicornioXXXX
. PROJECT NO.: UNIT NUMBER: _________________ PHASE NO.:
TYPE-OUNIT: sfd NUMBER OF-UNITS:'
CONTACT PERSON Sommer
CONTACT TELEPHONE 431-0822
all dent
INSPECTED, DATE
APPROVED V'7 DISAPPROVED
INSPECTED DATE .
BY: _______________________ INSPECTED: ____________ APPROVED ______ DISAPPROVED
INSPECTED •. DATE
BY: ________________________ INSPECTED: ____________ APPROVED DISAPPROVED
taMea1i MAR
COMMENTS: Engineering Department 1 9 1987
(6 19) 48b7 •
- .••.-
t MAR I U 19131 1 111111
.1 . - -. ________ * COSTARVA '
- .'- -
Rev. 1186 WHITE Suspen a BLUE: triater District REEW Engineering CANARY Utilities PINK Planning',,GOLD Fire
FINAL BUILDING INSPECTION
•••
.
PLAN CHECK NUMBER: 86334 DATE: 3-16-87
PROJECT NAME:
ADDRESS 2624 U7u6ornio9XXXX
PROJECT NO ______________ UNIT NUMBER ______________ PHASE NO
TYPE OF UNIT sfcl NUMBER OF UNITS 1
CONTACT PERSON Sommer
CONTACT TELEPHONE:'431-0822
all dent
INSPECTED
BY: INSPECTED:
DATE
APPROVED _____ DISAPPROVED
INSPECT DATE
APPROVED _____ DISAPPROVED
INSPECTED DATE
INSPECTED:•• APPROVED _____ DISAPROVED
COMMENTS JAf2)
Rev. 1186 WHITE Suspense BLUE Water District EngIneering CAARY Utilities PINK Planning GOLD Fire
ESGIL CORPORATION
9320 CHESAI'EAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619) 560.1468
DATE:
JURISDICTION: LIT\/ OF—
PLAN CHECK NO: 51341J2E
PROJECT ADDRESS: 2.(,2..Y (.flJI_oiafJiQ
PROJECT NAME: ¼)t*J+J .OJ'.-1N.P---
PLAN CHECKER
FILE COPY
UPS
DESIGNER
The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
RM with the jurisdiction's building codes when minor deficien-
JR identified Lc3 jIJtDE42.- M4are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies
U identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is for your information.
0 The p:lans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
fl The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
fl Esgil staff did not advise the applicant contact person that
plan check has been compl.te4
Esgil staff did 1 se a p(icant that the plan check has
been comPletPerso).#ontacted: j)p.
Date contacted: 1z..o/(' Telephone #FbL4fl7-fE*JT4-/L..
REMARKS: TO P2F_M/&1E. KJtT7j4.
r I
By:j4fl(7J4, (7. 4uEnclosures.:
ESGIL CORP01ATION
3/2c)fg -
AV
ESGIL CORPORATION
9320 CHESAI'EAKE DR., SUITE 208
SAN DIEGO, CA 92 123
(619) 560.1468
JURISDICTION: fl-\J Oi.
PLAN CHECK NO:
PROJECT ADDRESS: hVj UMl(.O.?JO
PROJECT NAME: 300LJ 4L$—
APPLICANT
IUTRTTD~ICTION
PLAN CHECKER
FILE COPY
UPS
DESIGNER
D The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes. S
The plans transmitted herewith will substantially comply
D with the jurisdiction's building codes when minor deficien-
cies identified - are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is for your information.
The p:lans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
.J0I4k) ncommEJ ) 1707 L) ALADJ LA
T2DOP
D Esgil staff did not advise the applicant contact person that
plan check has been completed.
Esgil staff did advise applicant that the plan check has
been completed. Person contacted: Jo14)J 3oi--EJ_
Date contacted: hoh)G Telephone #_L13(2, qzci
REMARKS:
By: JA 44LLjnc los ureS :____________________
ESGIL CORPORATION
PLAN CHECK NO:___________
JURISDICTION: UN OF- .ALS)DATE
Enclosures: W ,YVTTO )'
PROJECT ADDRESS: 2621/L))JiW$J10
TO: .)rFJ
7.flC4 Ai5
CtFY_ON- _7Z.bOP
Date plans received by jurisdiction______
Date plans received by plan checker_f/ii)?b
Date initial- plan check completed/IS16 by1F
5CL$
FORWARD:PLEASEREAD
Plan check is limited to technical requirements
contained in the Uniform Building Code, Uniform
Plumbing Code, Uniform Mechanical Code, National
Electrical Code and state laws regulating energy
conservation, noise attenuation and access for
the handicapped. The plan check is based on
regulations enforced by the Building Inspection
Department. You may have other corrections
.based on laws and ordinances enforced by the
Planning Department, Engineering Department
or other departments.
The items circled below need clarification,
modification or change. All, circled items have
to be satisfied before the plans will be in
conformance with the cited codes and regulations.
The approval of the plans does not permit the
violation of any state, county or city law.
A. PLANS
(?J Please make all corrections on the original
tracings and submit two new sets of prints,
and any original plan sets that may have
been returned to you by the jurisdiction,
to: 4L...JQJAr7tL)_17-tD£.t' JP.AJeL g_ 2QP
2 To facilitate rechecking, please identify,
next to each circled item, the sheet of
the plans upon which each correction On
this sheet has been made and return this
check sheet with the revised plans.
APPLICANT COPY
O JURISDICTION COPY
PLAN CHECKER COPY
FILE COPY
iIr zU
mm-AI
I
N.... -J
HBO
_
-
-1i-Ju
4JI1371 4
'I
flIE )OLL4DG 1CM SPECIFYDIG MAI3AICRY RUIRS SUOULD BE flRPCRAI3) ON PLAN OR
CDNrArM wTflffl4 JOB SPECIFICATION UoaMF2rlS.
MANDATORY EN2CY (NSERVATION RJIflS OF TME S= OF CALDtRNTA
All heating, ventilating, air conditioning, and water heating equipment shall meet all of the
requirements of the Appliance Efficiency Standards and shall be certified by the California Energy
Commission.
A two stage thermostat, which controls the supplementary heat on its second stage, shall be
provided for heat pumps.
Thermostats 'shall be equipped with an automatic setback, which the building occupant can program to
automatically set back the thermostat twice in 24 hours.
Equipment which requires preventive maintenance to maintain efficient operation shall be furnished
with complete necessary maintenance information.
All gas-fired fan type central furnaces, gas-fired fan type wall furnaces, and cooking appliances
shall be equipped with an intermittent ignition device.
All fan systems exhausting air to the outside shall be provided with backdraft dampers.
All transverse duct, plenum, and fitting joints shall be sealed with pressure sensitive tape or
mastic to prevent air loss and Shall be insulated to conform to the provisions of Section 1005 of
the UMC, 1982 Edition.
A vapor barrier is required in climate zone 1, lii, and 16.
All manufactured windows and sliding glass doors shall meet the 1972 ANSI air infiltration
standards and shall be certified and labeled.
All swinging doors and windows leading to unconditioned areas shall be fully weather-stripped.
Storage type water heaters and storage and backup tanks for solar systems shall be externally
wrapped with R-12 insulation or greater.
The five feet of pipe closest to the water heater, if outside conditioned space, shall be insulated
with a minimum of R-3. Steam and steam condensation return piping and recirculating hot water
piping outside the building envelope shall be insulated in accordance with T20-106(d).
Lamps used in luminaries for general lighting in kitchens and bathrooms shall have an efficiency of
not less than 25 lumens per watt.
(it.) Showerheads and faucets shall be equipped with flow restrictors as outlined in the appliance
efficiency standards and shall be certified to the Energy Commission.
Masonry and factory-built fireplaces on exterior walls, shall be equipped with tight-fitting
closeable metal or glass doors covering the entire opening of the firebox; a combustion air intake
equipped with a readily accessible, operable, and tight fitting damper to draw air from the outside
of the building; and a tight fitting flue damper with a readily accessible control.
Insulation used shall comply with California Quality Standards.
The insulation installer shall post.a signed certificate ... Section.276.. Insulation Certificate
(All Occupancies). After installing insulation, the installer shall post in a conspicuous location
in the building a certificate signed by the installer and the builder stating that the installation
conforms the requirements of Title 2, Part 2, Chapter 2-53, and that the materials installed
conform with the requirements of Title 20, Chapter 2, Subchapter I, Article 3. The certificate
shall state the manufacturer's name and material identification, the installed "R" value, and (in
applications of loose fill insulation) the minimum installed weight per square foot consistent with
the manufacturer's labeled density for the desired "R" value.
For infiltration control all openings and penetrations must be caulked and sealed, such as around
windows, at sole plates, and openings for utility pipes and wires.
Form ECH 3/5/86
ESGIL CORPORATION
9320 CHESAPEAKE DR.. SUITE 208
SAN DIEGO, CA 92123
(619) 560-1468
DATE: JUL'/ IB) lC
JURISDICTION: CITY OF CARLSBAD
PLAN CHECK NO: a3t-J =----
PROJECT ADDRESS: 2-4 u)Ico2jJIt)
APPLICANT
JURISDICT
FILE COPY
UPS
DESIGNER
R
PROJECT NAME: jOl4..4 .-1fr1i--
D The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
D with the jurisdiction's building codes when minor deficien-
cies identified are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith
in
is the jurisdiction's
copy for your information. The plans are being held at
Esgil Corp. until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
I70 9
q-7 00S
Esgil staff did not advise the applicant contact person that
plan check has been completed.
Esgil staff did advise applicant that the plan check has
been completed. Person contacted: -.H4--I
LEFT -trc- 73k'
Date contacted: Telephone #'-13B 9Zf
REMARKS:
BY: ENCL:
IL CORPORATI
TRLEP0NENO. LI,B-73G'
PROJE ADURS: .U,2LI Uf.J I oJ.Jl (2
Date plans received by Esgil Corporation:
Date initial plan check completed:
ifri By: TNIJPV
Applicant contact person:
*JF HNEJ& Telephone: 48-736
FOREWORD: PLEARE READ
Plan check is limited to technical requirements
contained in the Uniform Building Code, Uniform
Plumbing Code, Uniform Mechanical Code,
National Electrical Code and state laws
regulating energy conservation, noise
attenuation and access for the handicapped.
The plan check is based on regulations enforced
by the Building Inspection Department. You may
have other corrections based on laws and
ordinances enforced by the Planning Department,
Engineering Department or other departments.
Present California law mandates that
residential construction comply with Title 24
and the following model codes:
1982 UBC (eff. 7/1/85)
1982 UPC (eff. 10/1/85)
1984 NEC (eff. 10/1/85)
1982 UMC (eff. 3/1/85)
The above regulations apply to residential
construction, regardless of the code editions
adopted by ordinance.
The circled items need clarification,
modification or change. All items have to be
satisfied before the plans will be in
conformance with the cited codes and
regulations. Per Sec. 303 (c), 1982 Uniform
Building Code, the approval of the plans does
not permit the violation of any state, county
or city law.
S
PLAN C1M1XZ W. k
JURISDI(ION: Cli'! OF CARLSBAD
PLAN COMMMOIN SBE
STh.E FAMilY AND DOPM IBIELLThGS
Date plans received by jurisdiction:
To speed up the recheck process, note on this
list (or a copy) where each correction item has
been addressed i.e. • plan sheet • specification,
etc. Be sure to enclose the marked up list
when you submit the revised plans.
Carlsbad List 10, Single Family Dwelling and Duplex With All Supplements
1
3/25/86
A. PLANS
Qra
Please make all corrections on the original
cings and submit two new sets of prints, and
any original plan sets that may have been
returned to you by the jurisdiction, to:
Esgil Corporation, 9320 Chesapeake Drive,
Suite #208, San Diego, California 92123,
(619) 560-1468.
Please make all corrections on the original
tracings and submit two new sets of prints, and
any original plan sets that may have been
returned to you by the jurisdiction, to:
The jurisdiction's building department.
Indicate on the Title Sheet of the plans,
the name of the legal owner and name of person
responsible for the preparation of the plans.
Section 302 (a) 1.
,I/ Plans, specifications and calculations shall
be signed by a California state licensed
engineer or architect. (California Business and
Professions Code).
/Specify on the Title Sheet of the plans the
gross floor area of each element of this project
including dwelling, garage, carport, patio, deck
and balcony. Section 302 (c).
Qe
Provide a statement on the Title Sheet of
plans that this project shall comply with
Title 24 and 1982 UBC, UMC, and UPC and 1984
NEC.
7. Submit fully dimensioned plot plan drawn to
cale showing location, size, and use of all
existing and proposed structures on the lot.
Identify property lines and show lot dimensions
and all easements. Show location of all cut or
fill slopes and approximate finish floor
elevations for all structures and show
elevations at all lot corners.
Section 302 (c). (I I=,- T1*E1
2
3/25/86
Indicate distance from center line of street
or alley to property line and distance from
property lines to proposed building.
Section 302 (c).
B. FIRE PYIE(ION
Walls closer than 3 feet to property lines
shall be one-hour rated construction, have no
openings, and shall have 30 inch parapets when
the building floor area exceeds 1,000 square
feet on any floor.
(Table 5. A. Section 1109 (a)).
Projections, including eaves, may not
extend more than 12 inches into the 3 foot
setback from the property line. Eaves over
required windows shall be not less than 30
inches from the side and rear property lines.
Section 1710 and Section 504 (a) and (b).
Plastic skylights shall not be installed
within 8' of an exterior wall located where
openings in such exterior wall are prohibited or
required to be protected.
Section 5201 (a) 7.
Projections, including eaves, shall be
one-hour fire-resistive construction, heavy
timber or of noncombustible material if they
project into the 31 setback area from the
property line. Section 1710.
,/ Show location of permanently wired smoke
detector, centrally located in corridor leading
to sleeping rooms or above stair if sleeping
rooms are on upper level. Section 1210.
A smoke detector shall be installed in the
basement of dwelling units having a stairway
which opens from the basement into the dwelling.
Such detector shall be connected to a sounding
device or other detector to provide an alarm
which will be audible in the sleeping area.
Section 1210.
D. XKUS, St&I1JAYS, AND RAILINGS
,XC'Floors, above the second story shall have
not less than 2 exits. Section 3303 (a).
Required exit doorways shall be not less
than 36" in width and not less than 618" in
height, and shall be capable of opening at least
90 degrees. Section 3304 (a).
)a'Provide 36" high protective railing for
porches, balconies, and open sides of stair
landings. Openings between railings shall -be
less than 611. Section 1711.
Show how guardrail connection details are
adequate to support 20 pounds per lineal foot at
a right angle to the top rail. Table 23-B.
,/ Provide stairway and landing details.
Section 3306 (b) & (c).
Maximum rise 8" and minimum run is
,/Minimum headroom is 61611.
,/' Minimum width is 30".
Q..1ihandrails per Section 3306 (j), shall
satisfy the following:
)r("Every stairway landing shall have a
dimension, measured in the direction of travel,
at least equal to the stairway width.
Section 3306 (g).
A door may open over a stairway landing
provided thedoor, in any position, does not
reduce the clear area of the landing in the
direction of stairway travel, to less than
one-half the required width of the stairway.
Section 3306 (g).
door may open inward at the top step of a
stairway provided the top step is not more than
7 1/2" lower than the.-floor level.
Section 3304 (Ii).
)rovide details of winding stairway
complying with Section 3306 (d):
Minimum tread is 6 inches at any point
and minimum 9 inches at a point 12
inches from where the treads are
narrowest.
Maximum rise is 8 inches.
C. Minimum width is 30 inches.
)4 'Provide spiral stairway details, per
Section 3306 (f):
() Provide handrail for stairways with 4 a. Minimum run is 7 1/2 inches measured
or more risers. C)).) flF.- at a point 12 inches from where the
treads are the narrowest.
Handrail shall be 30" to 34" above the
nosing of treads.
handgrip portion of handrail shall
be not less than 1 1/4" nor more than
211 -in cross-sectional dimension.
(See attached).
4
3/25/86
b. Maximum rise is 9 1/2 inches.
C. Minimum headroom is 6 feet 6 inches.
stairways may not be used for
required exits when the area served is greater
than 400 sq. ft. Section 3306 (f).
Spiral stairways must have a clear walking
space of 26 inches between the column and
handrail, show dimension. Section 3306 (f).
,JciC';rovide I.C.B.0. Research Report and Number
for metal stairway, or submit plans and
calculations and approved fabricator registered
with the building department or note that the
stairway fabrication shall be done under special
inspection per the approved fabrication plans.
Section 306 (a) 4B and Section 306 (f).
,Ivf'in buildings over 2 stories in height,
provide 3/4 hour fire-rated assemblies for all
openings in the exterior wall below or within 10
feet horizontally of an exterior stairway. An
exit balcony with 2 separated stairways is
exempt. Section 3306 (1).
stairways shall not project into
the 3 foot setback from the property lines.
Section 3306 (n).
,kT 'The walls and soffits of the enclosed
usable space under interior stairs shall be
protected on the enclosed side as required for
one-hour fire-resistive construction.
Section 3306 (m).
E. FMOFM
roof slope.
)9Ioof slope is not adequate for roof type
specified. Table 32-B; Section 3203 (h).
50. Specify roof material and application.
pter 32.
Vr
Specify I.C.B.0. or U.L. approval number
roof materials not covered in U.B.C., e.g.,
tit1, etc., Section 107.
11L
5
3/25/86.
The maximum slope .for a fire retardant
built-up roof, with rock or gravel surfacing, is
3 inches in 12 inches, Section 3203 (e) 2.
The minimum slope for a fire retardant
built-up roof, with cap-sheet surfacing, is 1/2
inch in 12 inches. Section 3203 (e) 3.
Specify minimum 1/4 inch per foot roof
slope for drainage or design to support
accumulated water. Section 3201 (a), Section
2305 (f) and Section 2511 (d) 6.
Show roof drains and overflows.
Section 3201.
Q56. Provide skylight details to show compliance
wi Sections 3401 and 5207 or provide I.C.B.0.
approval number.
Plastic skylight must be separated from
each other by at least 4 feet.
Section 5207 (a) 6.
Show attic.ventilation. Minimum vent area G
is 1/150 of attic area or 1/300 of attic area if
at least 50% of the required vent is at least 3
feet above eave vents or cornice vents. Show
required area and area provided.
Section 3205 (c).
F. NASMW
Provide fireplace construction details or
note construction to be per attached fireplace
standard drawing. Chapter 37.
Show veneer support and connections in
'Seismic Zones 3 and 4, comply with Section 3002,
4, 5, 6, and Section 2515 (a) regarding ties and
#9 wire in horizontal joints or show
construction- to be per attached sheets
30-1 or 30-2.
Show height and construction details of all
masonry walls. Chapter 24.
flf'Note that cleanout openings shall be
provided at the bottom of all cells to be grout
filled over 4' in a single pour. Cleanout shall
be sealed before grouting, after inspection.
Section 2414 (a) B.
Show floor and roof connections to masonry
walls. Connection shall resist 200 poundsper
lineal foot or the actual design load, whichever
is greater. Cross grain tension or bending in
wood ledgers is not permitted.
Section 2312 (j) 3. A.
)4"Provide details for damp proofing the
foundation walls, below finish grade, where
useable space exists on the interior side of the
walls. Section 1707 (d).
Show a minimum 2" air space and flashing
between planter and building walls.
Section 2516 (c) 7.
7i : iIi1,1 ; 1
Garage requires one-hour fire protection on
the garage side of walls and ceiling coon to
the dwelling. Table 5. B. Section 503 (d).
Qclu
All elements supporting floor above garage,
ding walls supporting floor joists, to have
one-hour fire-resistive protection on the garage
side. Seption 503 (a). E_. C.0L4.E_"flD"' *i-!B9
Show 1 3/8" solid core self-closing door
for openings between garage and dwelling.
Section 503 (d).
Openings between carport and residence
require self-closing doors and stationary
windows. Section 1214.
)"Show garage framing section, size of header
over garage opening, lateral cross bracing at
plate line, method of bracing garage front, and
holddowns if required. chapter 23.
NOTE: Maximuth shear panel ratio of height to
width is 3 1/2 to 1. Table 25-I.
Doors may open into the garage only if the
floor or landing in the garage is not more than
1/2" lower than the door threshold.
Section 3304 (h).
an 18" raised platform for any FAU,
water heater, or other device in the garage,
which may generate a flame or spark, UMC Section
508, UPC Section 1310 (a).
H. FOUNDATION xsijui
() Per soils report, note on the plan the
soils classification, whether or not the soil is
expansive, and note the allowable bearing value.
Section 2905 (c).
Qa
The foundation plan does not comply with
soil report recommendation for this project.
'Please review the report and modify design,
notes and details as required t
%
o show
comiance. - t...O
,7( Provide notes on' the foundation plan
listing the soils report recommendations for
foundations, slab and building pad preparation.
J01100,Garages are not permitted to open into a
room used for sleeping purposes. Section 1104.
6
3/25/86
The soils report recommends excavations be
reviewed by soils engineer. Note on the
foundation plan that "Prior to the Contractor
requesting a Building Department Foundation
Inspection, the soils engineer shall advise the
building official in writing that:
the building pad was prepared in
accordance with the soils report;
the utility trenches have been
properly bankfilled and compacted,
and;
the foundation excavations, formings
and reinforcements comply with the
soils report and approved plan".
Show height of all foundation walls.
Chapter 23.
Show height of retained earth on all
foundation walls. Chapter 23.
~)foundation
If cut or fill slopes exist, show distance
to edge of cut or fill slopes and
show steepness and heights of cuts arid fills.
Chapter 29. CE.E.... )
Note oJV n plans that wood shall be 6"
minimum above finish grade.
Section 2516 (c) 7.
)Z'('Note on plans that surface water will drain
away from building and show drainage pattern and
key elevations. Section 2905 (f).
Dimension foundation per U.B.C. Table 29A:
Floors
Supported* Steinwall Width Depth
1 6" 12" 12"
2 all 15" 18"
3 10" 18" 24"
,81C'how foundation sills to be pressure
treated, or equal. Section 2516 (c) 3.
Show foundation bolt size and spacing.
Section 2907 (e).
Quf
Specify size, I.C.B.0. number and
acturer of power driven pins. Show edg
and end distance and spacing.
Section 306 (f).
If required by structural calculations,
show size, imbedment and location of hold down
anchors on foundation plan. Section 2312 (f).
If hold downs are required by calculations,
note on plan that hold down anchors must be tied
in place prior to foundation inspection.
Section 305 (e) 2.
G89. Show adequate footings under all bearing
.walls and shear wall . Sectjon 2907 (bL.
____ t'L)170JLfl (— C... .J
Show on the elevations, stepped footings
for slopes steeper than 1:10.
Section 2907 (c).
minimum 18" clearance from grade to
~/Otto:howof floor joists and minimum 12"
clearance to bottom of girders.
Section 2516 (c).
Show pier size, spacing and depth into
undisturbed soil. Table 29-A.
Show minimum underfloor access of 18" x
24". Section 2516 (c).
Show minimum underfloor ventilation equal
to 1 sq. ft. for each 150 sq. ft. of underfloor
area. Openings shall be as close to corners as
practicable and shall provide cross ventilation
on at least two approximately opposite sides.
Section 2516 (c).
*Foundations may support a roof in addition to
the floors. Where only a roof is. supported, use
foundation for one floor.
7
3/25/86
e9z" Specify that posts embedded in concrete
shall be pressure treated per UBC Std. No. 25-
12. Section 2516 (c).
I. FRANIIE
eud
Show wall bracing. Every exterior wood
wall and main cross partition shall be
braced at each end at least every 25 feet of
length with 1 x.4 diagonal let-in braces or
equivalent. Section 2 17 (g) 3. eLo
,9( Note cross bridging or blocking. Floor
joists and rafters 12" or more in depth shall be
supported laterally by bridging at intervals not
exceeding 8 feet, unless both edges are held in
line. Sec. 2506 (g).
QOor
Show blocking at ends and at supports of
joists, and for rafters at exterior walls.
Section 2517 (d) 3.
/Show solid blocking at ridge line and at
exterior walls on trussed roofs.
Section 2506 (g), Section 2517 (h).
KOU Show double joists. Floor joists shall be
d under bearing partitions running
parallel with the joists. Section 2517 (d) 5.
01. Bearing partitions, perpendicular to
j sts, shall not be offset from supporting
girders, beams, walls or partitions, more than
the depth of the joist. Section 2517 (d) 5.
(- -)C lTE_ 9)
Show rafter ties. Rafter ties shall be
spaced not more than 4 feet on center and be
just above the ceiling joists, where rafters and
ceiling joists are not parallel.
Section 2511 (h) 4.
Show rafter purlin braces to be not less
than 45 degrees to the horizontal.
Section 2517 (h) 5.
Show 1/2" minimum clearance between top
plate of interior partitions and bottom chord of
trusses. (To ensure loading will be as
designed).
05. Show double top plate with minimum 48"
1 splice. Section 2517 (g) 2.
0
Ql
Show nailing will be in compliance with
e 25-Q.
107 Show or note fire stops at the following
locations per Section 2516 (f):
in concealed spaces of stud walls and
partitions, including furred spaces,
at the ceiling and floor levels and at
10 foot intervals along the length of
the wall.
at all interconnections between
concealed vertical and horizontal
spaces such as occur at soffits, drop
ceilings and cove ceilings;
C. in concealed spaces between stair
stringers at the top and bottom of the
run and between studs along and in
line with the run of stairs if the
walls under the stairs are unfinished;
and
d. in openings around vents, pipes,
ducts, chimneys, fireplaces and
similar openings which afford a
passage for fire at ceiling and floor
levels, with noncombustible
materials.
)98'Show stud size and spacing. Maximum
allowable stud heights; Bearing wall: 2 x 4 and
2 x 6 max. 101; Non-bearing: 2 x 4 max. 141, 2
x 6 max. 20'. Table 25-R-3.
Studs supporting two floors, a roof and
ceiling must be 3 x 4 or 2 x 6 at 16" o.c.
Table 25-R-3.
G 5HDO , "v,-) 16T- '5Tp&_N AJQ 21"-W pJ.-L.L
QiQ-i.cE.O. (L.EJ 9...3 f-f fr.'l pJor- t 0'
I = " -' ptLJ=. NO. Al: -E )IP-E. 3><
F --)O o T7J 3/25/86
X
Note an A.I.T.C. Certificate of Compliance
for glued laminated wood members shall be given
to the building inspector prior to erection.
Section 306 M.
011. Detail all post to beam and post to
ooting connections and reference the detail to
the plan. Section 2516 (in).
(Detail shear transfer connections, ) 9including roof and floor diaphragms, to shear
walls. Section 2513. (9EE... LOW)
9113 Specify nail size and spacing for all
s ear walls, floor and roof diaphragms.
Indicate required blocking. Maintain maximum
diaphragm dimension ratios. (Tables 25 I, .1, K)
and Section 4713 (d).
y4( Show 3" x 4" or 2" x 6" studs in first
story of three story building. Table 25-R-3.
e Provide truss details and truss
ulations for this project.
Provide roof framing plan and floor
'framing plan. Section 302 (a) 7.
,
)rirovide framing sections through
Section 320 (a) 7.
"pecify all header sizes for opening over
4 wide. Section 2517 () S.
(S Provide calculations for main vertical and d
horizontal framing members and post footings.
Section 302 (a) 7. 10
)O'irovide calculations for lateral loads,
shear panels, shear transfer and related.
Section 302 (9) 7.
,)&I. on the plans all structural
requirements developed in the structural
calculations.
/
2 Columns and posts located on concrete or
masonry floors or decks exposed to the weather
or to water splash or in basements and which
support permanent structures shall be supported
by concrete piers or metal pedestals projecting
above floors unless approved wood of natural
resistance to decay or treated wood is used.
Section 2516 (c) 4.
123. Individual concrete or masonry piers shall
p oject at least 8 inches above exposed ground
unless the columns or posts which they support
are of approved wood of natural resistance to
decay or treated wood >is used. ,
A'-'ion 2516 i't> lb A.LJ u k2
p) itJr TO ri O%L
),121 Show location of attic access with minimum
size 22" x 30". Section 3205.
Show draft separation for attic areas
between units in a duplex. Section 2516 (f).
).2(ilood stud bearing walls, with studs at 24"
o.c., require 3 em. 2 x 4 or 2 ea. 2 x 6 or 2
ea. 3 x 4 top plates if supporting either floor
members or roof trusses that are spaced more
than 16" o.c. and do not bear within 5" of the
supporting stud. Section 2517 (g) 2.
0127. Specify plywood grade and panel
i entification index. Table 25- goof=r-c1- - E..
When roof pitch is less than 3:12, design
ridge as a beam. Section 2517 (h).
If foundation cripple wall studs are less
than lie" framing shall be solid blocking.
Section 2517 (g) 4.
7
9
3/25/86
)2d'Cripple wall studs exceeding 4 feet in
height shall be 3 inch by 4 inch or 2 inches by
6 inches when supporting 2 stories.
Section 2517 (g) 4.
131 Show plywood sheathing over exposed eaves,
o other weather exposed areas, is exterior
grade. Section 2516 (g) 3.6t)( 01L-1MWN"-1—
Se
' iLul-EJ,
Show a weepscreed at the foundation plate
on all exterior and stud walls to be
stuccoed. Section 4706 (e).
0ect
Show corridor width to be minimum 36".
ion 3305 (b). .EL-J€.L..O%'J
Specify truss layout for 30" x 30" attic
access.
Ridges, hips, and valleys shall be at
least one size larger than supported rafters.
Section 2517 (h) 3.
In open beam construction, provide strap
ties across the beams at the ridge support.
Section 2501 (b).
J. MANICAL
All heating, ventilating, and cooling systems
and appliances shall comply with the Uniform
Mechanical Code.
137 Show the size, location and type of all
tine and cooling appliances or systems.
Show source of combustion air to furnace,
per Chapter 6, UMC.
/9- Every dwelling unit shall be provided with
heating facilities capable of maintaining a room
temperature of 70 degrees F. at 3 feet above the
floor in all habitable rooms. Show basis for
compliance. UBC, Section 1211.
10
3/25/86
Show minimum 30" deep unobstructed working
4pace in front of furnace. Section 505, UMC.
Dufacturer's
Note on plans, clearances to be per
listing. Section 504, UMC.
Furnace shall not be installed under any
'stairway. Section 704, UMC.
rbMoom
shall not be installed in any
6edroo or in a closet or confined
space with access only through such room, unless
specified as direct vent appliance, enclosed
furnace or electric heating appliance.
Section 704, UMC.
F31r
. Show I.C.B.0. approval number for prefab
eplace.
Show access to the attic or underfloor
1furnace to be minimum 30 inches by 30 inches.
Section 708 & 709 UMC.
Note that passageway to the attic furnace
shail be unobstructed and have continuous solid
flooring not less than 24 inches wide.
Section 708, UMC.
)Jd ' Show permanent electrical outlet and
lighting fixture controlled by a switch for the
atticfurnace. Section 708, UMC.
y.e 'Show details to comply with Section 709
for furnace under the floor, or Section 710 for
roof or outside furnace.
() 149 Note on plan: Gas vents and
noncombustible piping passing through three
floors or less shall be effectively draft
stopped at each floor or ceiling.
UBC, Section 1706 (a) 6.
ZJ
RLMMICAL (NATIONAL ELICAL Q)DE)
All wiring shall comply with the National
Electrical Code.
;
Show on the plan the amperage of the
0 trical service, the location of the service
anel and the location of any sub-panels.
Show location of all electrical
receptacles.
152 Electrical receptacle locations and/or
s c
.
ing is not adequate in
/3- Show at least one convenience outlet other
than outlets for laundry, etc., outdoors, in
garages and basements. NEC, Art. 210-52.
Note convenience outlets in bathrooms,
outdoors, and in garages and basements (other
than for laundry and similar equipment) shall be
GFI protected, NEC, Art. 210-8.
Note electrical system ground to be
prôvided per NEC, Art. 250-81.,
L. PLUNBThG (wtu'u1( PUJMBING ZDI)
Oplans.
Show water heater size, type and location
UPC, Section 1310.
Show source for providing combustion air
to fuel burning water heater. If wall opening
in an enclosure are used, at least one-half of
the required opening area shall extend into the
upper twelve inches of the enclosure and
one-half within the lower twelve inches.
UPC, Section 1307.
11
3/25/86
Fuel combustion water heater shall not be
installed in bath' or bedroom or in a closet
opening into bath or bedroom.
UPC, Section 1309.
"Provide adequate barrier to protect water
heater from vehicle damage. UPC, Section 1310.
160. Show T and P Valve on water heater and
s w route of discharge line to exterior.
UPC, Section 1007 (e).
Q
Q
161 Provide dryer vent to outside.
, Section 1903.
. Note on the plan that hose bibbs and lawn
s inkler systems shall have approved backf low
prevention devices. UPC, Section 1003.
163 Shower stall shall accommodate a 30"
circle and have a minimum floor area of
1,024 sq. in. UPC, 909 (d).
NOISE INSULATION (1XJPL)
details of duplex common (party)
walls and floor/ceiling assemblies to achieve a
Sound Transmission Class (STC) rating in walls
of 50 decibles and on Impact Insulation Class
(IIC) rating on floor/ceiling of 50 decibles.
Title 25.
,~6~Show how penetrations of assemblies for
piping, electrical devices, recessed cabinets,
bathtubs, soffits, or heating ventilating, or
exhaust ducts shall be sealed, lined, or
insulated to maintain required sound
transmission rating Title 25.
rovide insulation in walls and ceiling to
achieve SIC of 50 between garage and living area
if garage use is not controlled by resident.
Title 25.
N. REGY CONSERVATION: PLEASE READ
State regulations (California Admin. Code)
require that the design satisy one of the
attached alternative energy packages or submit
calculations. The law also requires that many
mandatory conservation items be satisfied.
y6 Show on the Title Sheet of the plans, the
required element of the alternative energy
package that was selected, and next to each
element show how you are complying with each
element. If calculations were used, provide
similar data on the plans.
The plan sheet showing the required
elements of the selected energy package, and
listing the design elements showing compliance
with that selected package, must be signed by
either the owner or a licensed professional
i.e., architect, engineer or contractor. A
design professional must note his/her state
license number. Section 1403 of Title 20.
)M('Show on the plans the "R" value for the
walls, floors, ceiling and related areas.
Show double glazing as per Energy Design,
on Glazing Schedule.
Show on the plan how shading requirements
are satisfied.
The plans are not in compliance with the
'energy conservation compliance package selected
or design calculations provided. Show on plans
conformance as follows:
Q
Specify on the building plans all of the
atory energy conservation requirements as
listed on the enclosure titled, "Mandatory
Energy Conservation Requirements".
Qati
Show the size, type, make, model and
on of the space heating (or cooling)
system and provide heat loss calculations if the
output BTU/Hr. exceeds 45,000.
0. CARLSBIID S.F.D. & DUMCK SUPPLIEIIT
175 Energy conservation design should be for
ne 7 . See attached energy packages.
176. Floor drains must have auto-prime
ty policy).
p
Note exhaust fans cannot be ductless type
y policy).
0
178.178. New residential units must be pre-plumbed
future solar water heating. Note "two roof
jacks must be installed" where the water heater
is in the one story garage and directly below
the most south facing roof
(City Ordinance No. 8093).
Note "two 3/4" copper pipes must be
installed to the most convenient future solar
panel location when the water heater is not in a
one story garage and is not directly below the
most south facing roof.
(City Ordinance No. 8093).
180 All piping for present or future solar
er heating must be insulated when in areas
that are not heated or cooled by mechanical
means (city policy).
X. Incorporate the waterproofing details, on
the attached Policy 80-8, where interior living
space occurs below grade at the masonry
wall(s).
12
3/25/86
5182. Show on the Title Sheet on the plans, the
i. ormation required by the attached
Developmental Services Sheet 102683.
All new residential buildings, including
dditions, require a soils report. Please
submit two copies.
(c) Heavy timber framing, minimum 6" x 10"
~ns and minimum 8" x 8" post, for the
structural beam and column supporting the fire
separation between the garage and living area
above, is acceptable if shown on the plans.
(city policy). 14c(, yor'
e
T?1
t
uditional corrections, or
on llowing .page.
The City of Carlsbad has contracted with Esgil
Corporation located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123;
telephone number of 619/560-1468, to perform the
plan check for your project. If you have any
questions regarding these plan check items,
pleasecontact____________________________
at Esgil Corporation. If you have any questions
regarding City Building permit procedures,
please contact Carter Darnell at the City of
Carlsbad, 1200 Elm Avenue,
telephone 619/438-5525.
Thank you.
Enclosures:
13
3/25/86
-
iz4iJ'
-
1!b W
[l5.dv5I—_
TOE FOLLJflG N= SPECIFYnr. MANDATORY RUIR4ERIS SIIOULD BE INCORPORATED ON FlAil SHXlS, OR
CONThDiED W1N JOB SPECIFICATION DOCUMENTS.
MANDATORY ENERGY CONSERVATION REGUIREMLYrS OF THE STATE OF CALIFORNIA
All heating, ventilating, air conditioning, and water heating equipment shall meet all of the
requirements of the Appliance Efficiency Standards and shall be certified by the California Energy
Commission.
A two stage thermostat, which controls the supplementary heat on its second stage, shall be
provided for heat pumps.
Thermostats 'shall be equipped with an automatic setback, which the building occupant can program to
automatically set back the thermostat twice in 24 hours.
Equipment which requires preventive maintenance to maintain efficient operation shall be furnished
with complete necessary maintenance information.
All gas-fired fan type central furnaces, gas-fired fan type wall furnaces, and cooking appliances
shall be equipped with an intermittent ignition device.
All fan systems exhausting air to the outside shall be provided with backdraft dampers.
(1) All transverse duct, plenum, and fitting joints shall be sealed with pressure sensitive tape or
mastic to prevent air loss and shall be insulated to conform to the provisions of Section 1005 of
the UMC, 1982 Edition.
A vapor barrier is required in climate zone 1, lIe, and 16.
All manufactured windows and sliding glass doors shall meet the 1972 ANSI air infiltration
standards and shall be certified and labeled.
All swinging doors and windows leading to unconditioned areas shall be fully weather-stripped.
Storage type water heaters and storage and backup tanks for solar systems shall be externally
wrapped with R-12 insulation or greater.
The five feet of pipe closest to the water heater, if outside conditioned space, shall be insulated
with a minimum of R-3. Steam and steam condensation return piping and recirculating hot water
piping outside the building envelope shall be insulated in accordance with T20-11e06(d).
Lamps used in luminaries for general lighting in kitchens and bathrooms shall have an efficiency of
not less than.25 lumens per watt.
Showerheads and faucets shall be equipped with flow restrictors as outlined in the appliance
efficiency standards and shall be certified to the Energy Commission.
Masonry and factory-built fireplaces on exterior walls, shall be equipped with tight-fitting
closeable metal or glass doors covering the entire opening of the firebox; a combustion air intake
equipped with a readily accessible, operable, and tight fitting damper to draw air from the outside
of the building; and a tight fitting flue damper with a readily accessible control.
Insulation used shall comply with California Quality Standards.
- (17) The insulation installer shall post.a signed certificate ... Section.276.. Insulation Certificate
(All Occupancies). After installing insulation, the installer shall post in a conspicuous location
in the building a certificate signed by the installer and the builder stating that the installation
conforms the requirements of Title 24, Part 2, Chapter 2-53, and that the materials installed
conform with the requirements of Title 20, Chapter 2, Subchapter 4, Article 3. The certificate
shall state the manufacturer's name and material identification, the installed "R" value, and (in
applications of loose fill insulation) the minimum installed weight per square foot consistent with
the manufacturer's labeled density for the desired "R" value.
(18) For infiltration control all openings and penetrations must be caulked and sealed, such as around
windows, at sole plates, and openings for utility pipes and wires.
Form ECH 3/5/86
CITY OF CARL3BAO
Table 7. Alternative Component Packages, Climate Zone 7
Building Measure
Package Designation
-- - - - - - - -
INSULATION R-VALUE MINIMUM
Ceiling 19 30 19 30 30 30 19 30 19 30 19
Wall 11 ii 11 11 IL 11 Li U 11 11 11
"Heavy" Wall 2.5 2.5 2.5 NA NA. 2.5 2.5 2.5 2.5 2.5 2.5
Light Mass" WalL 4.0 3.5 3.5 NA NA NA NA NA NA NA NA
Slab Floor Perimeter MR 7 MR Ni NA HR HR Ni HR 7 HR
Raised Floor 11 11 11 NA 19 HR Ni 19 19 11 11
Arrlc3 Ni HR Ni. REQ REQ REQ NH. REQ MR HR NR
GLAZING
Maximum U-Value 1.1 .65 1.1 .65 .65 .65 1.1 .65 1.1 .65 .65
Maximum Total Area Z NH. 14 14 20 20 20 24 20 24 HR. Ni
Maximum Total Macsouth
Area Z. 9.6NANA NA- NA. NRNRNRNR8.49.6
Minimum Total South
Area Z 6.4 NR Ni HR Ni HR HR Ni Ni 5.6 6.4
RADING COEFFICIENT
South-facing Glazing Ni Ni Ni Ni Ni Ni Ni Ni MR Ni Ni
West-facing Glazing Ni Ni NH. Ni .36 HR. Ni Ni HR NH. NH.
North-facing Glazing Ni Ni Ni Ni Ni Ni Ni NH. NH. Ni NR,
East-facing Glazing Ni Ni MR Ni Ni NB. NH. Ni Ni Ni Ni
BERMAL MASS EQUIVALENT
Z Slab Floor Exposedi8 50 Ni NH. 25 5 25 25 20 15 Ni 50
NFILTRATIOU CONTROL
Continuous Barrier Ni Ni Ni Ni Ni Ni NH. Ni NH. Ni Ni
:lectrjcaj. Outlet Plate Ni Ni Ni Ni NB. MR. Ni Ni NH. Ni NH.
Caskets
fr-To-Air Heat Exchanger Ni Ni MR Ni Ni NH. NR Ni NE NH. Ni
PACE HEATING SYSTEM
Gas Furnace Seasonal
Efficiency Z • HIM HIM HIM HIM MIN MIN HIM MIN MIN
Heat Pump ACOP 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
Electric Resistance" NO NO NO NO NO NO NO NO NO YES YES
PACE COOLING SYSTEM
A/C or Heat Pump SEER
ATER HEATING SYSTEM
Gas Heat Pump or Solar
with Any Backup REQ REQ REQ REQ REQ REQ REQ REQ
Solar with Gas Backup REQ REQ REQ
Appendix B
3-9
C-70 AC? - itt'&te5
A
5
Table 17. Notes for Tables 1 through 16
LEGEND: NE - Not required, N/A - Not applicable, . REQ - Required, MIN - Minimum efficiencies required by Section 2-5306 of the regulation. NO Heating system type not allowed, YES - Heating system type allowed.
3. Whenever an attic is required, it must cov
e
r
a
t
l
e
a
s
t
t
h
r
e
e
-
q
u
a
r
t
e
r
s
(3/4) of the ceiling area over conditioned apace and b
e
v
e
n
t
e
d
.
7. In alternative component packages which req
u
i
r
e
t
h
e
r
m
a
l
m
a
s
s
(
o
t
h
e
r
than Package A), the specified percentage of mass must be directly exposed to the conditioned space. To determine the floor area directly exposed to the conditioned space. To determine the floo
r
a
r
e
a
,
c
o
u
n
t
o
n
l
y
t
h
e
f
i
r
s
t
floor in conditioned areas. Uncarpeted fi
r
s
t
f
l
o
o
r
a
r
e
a
s
,
s
u
c
h
a
s
linoleum or tiled entry ways, kitchens, bathrooms, and
u
t
i
l
i
t
y
c
l
o
s
e
t
s
may all be counted towards this requirement.
S. Thermal mass required for Packages E,1,2,3 and
4
m
u
s
t
b
e
e
i
t
h
e
r
equivalent to a slab floor covering one-fourt
h
(
2
5
p
e
r
c
e
n
t
)
o
f
t
h
e
f
l
o
o
r
area with a thickness of at least 2 inches a
n
d
a
v
o
l
u
m
e
t
r
i
c
h
e
a
t
c
a
p
a
c
i
t
y
of 28 3tu/ft3 °F (see below for surface ar
e
a
o
f
m
a
t
e
r
i
a
l
s
e
x
a
m
p
l
e
s
)
o
r
provide the minimum total mass capacity listed in Table 17. of Appendix A (use the Point System to calculate the mass for other materials).
4" brick Concrete block 90 pcf Concrete block 140 pcf Climate Slab exposed block density, block density, solid Zone Floor Z one side grouted grouted 4 6 4". 6" - 15 21 18 17 14 13 20 28 24 22 18 18 7 25 35 30 28. 23 22
11. For Packages 5 and 6 electric resistance and radiant heat
i
n
g
s
y
s
t
e
m
s
shall have two or more separately controlled zones in each dwe
l
l
i
n
g
unit.
Date* 7/14fb
Prepared byt
i-;
CITY OF CARLSBAD
Bldg. Dept.
VALUATION AND PLAN CHECK FEE o Esgi].
PLAN CHECK NO. No 3Y-1
BUILDING ADDRESS _2.V4 JoEJ.J1O
APPLICANT/CONTACT JDkJ PHONE NO. Lt
BUILDING OCCUPANCY _2/ M I DESIGNER PHONE__
TYPE OF coNSTRUCTIoN _I.J CONTRACTOR PHONE__________
BUILDING PORTION BUILDING AREA VALUATION
MULTIPLIER
VALUE
- T#c / Do 41 cBj e,
L4 t:)-7 9 4
iEEF Pcc4 4
Lc(z) 4 'ft &000
Air Conditioning
Commercial
Residential
Res. or Comm.
Fire_S,rinkler
Total Value 4j z _)5)L)5 s
Fee Adjusted To Reflect 0 Energy Regulations (Fee x 1.1)
(:)Handicapped Regulations (Fee x 1.065)
Building Permit Fee $
Plan Check Fee $ $ 3510,2.0
C 0 M MEN TS?
0/4/82
Project No. 71-7-17D -2- October 19, 1972 La Costa Land Company
Test Number Week Ending
361 to 404, inclusive October 2, 1971 405 to 456, inclusive October 9, 1971 457 to 507, inclusive October 16, 1971 508 to 538, Inclusive October 30, 1971 539 to 570, inclusive November 6, 1971 571 to621, inclusive November 13, 1971 622 to 675, inclusive November 20, 1971. 676 to 701, inclusive November 27, 1971 702 to 771, inclusive December 4, 1971 772 to 835, inclusive December 11, 1971 836 to 905, inclusive December 18, 1971 906 to 924, inclusive December 25, 1971 925 to 930, Inclusive July 15, 1972 931 to 935, inclusive July 22, 1972
The final results of tests and observations indicate that th
e
c
o
m
p
a
c
t
e
d
f
i
l
l
e
d
g
r
o
u
n
d
h
a
s
b
e
e
n
placed at 90 percent of the maximum dry density or gr
e
a
t
e
r
.
I
t
h
a
s
b
e
e
n
d
e
t
e
r
m
i
n
e
d
t
h
a
t
t
h
e
.
fill materials, compacted to 90 percent of the maximum dr
y
d
e
n
s
i
t
y
,
h
a
v
e
a
s
a
f
e
b
e
a
r
i
n
g
v
a
l
u
e
of 1930 pounds per square foot for one foot wide continuo
u
s
f
o
o
t
i
n
g
s
f
o
u
n
d
e
d
a
t
a
m
i
n
i
m
u
m
depth and placed five feet or more Inside the top of com
p
a
c
t
e
d
f
i
l
l
e
d
g
r
o
u
n
d
s
l
o
p
e
s
.
I
f
f
o
o
t
i
n
g
s
are placed closer to the exposed slopes than 5 feet inside the top of compacted filled ground slopes, these should be deepened one foot below a 1 1/
2
h
o
r
i
z
o
n
t
a
l
t
o
1
v
e
r
t
i
c
a
l
l
i
n
e
p
r
o
j
e
c
t
e
d
outward and downward from a point 5 feet horizontally
i
n
s
i
d
e
t
h
e
t
o
p
o
f
c
o
m
p
a
c
t
e
d
f
i
l
l
e
d
ground slopes. Tests indicate that the compacted filled
g
r
o
u
n
d
i
s
a
d
e
q
u
a
t
e
t
o
s
a
t
i
s
f
a
c
t
o
r
i
l
y
support the proposed wood frame dwellings without detr
i
m
e
n
t
a
l
s
e
t
t
l
e
m
e
n
t
s
.
Expansive clay, silty clay, and sandy clay soils were p
l
a
c
e
d
i
n
t
h
e
u
p
p
e
r
t
h
r
e
e
f
e
e
t
i
n
c
e
r
t
a
i
n
compacted fill areas and also exist in the upper three f
e
e
t
b
e
l
o
w
f
i
n
i
s
h
e
d
g
r
a
d
e
i
n
c
e
r
t
a
i
n
c
u
t
areas. The final classifications of the soil conditions exi
s
t
i
n
g
o
n
e
a
c
h
l
o
t
a
r
e
p
r
e
s
e
n
t
e
d
a
s
follows:
To A - Critically Expansive Soils
Lots
413 t6430, inclusive
432 to 435, Inclusive
437 to 441, inclusive
446 to 450, inclusive
(452 to 454, inclusive
45 o 466, inclusive
470 Do 487, Inclusive
489 to 510, inclusive / 512 to 527, Inclusive
Lots
531 to 534, Inclusive
536 to 540, inclusive
543 to 55 , clusive
554,556, 7 558
563, 564, 570, 574
575, 576
578 to 581, inclusive
584
BENTON ENGINEERING. INC.
Project No. 71-7-17D -3- October 19, 1972 La Costa Land Company
Type B - Marginally Expansive .Soils
Lots
431 and 436
442 to usive
45
V445
45 clusive
467 inclusive
488, 511
Lots
528, 529, 530, 535
542, 555, 560, 565
566, 568, 569, 571
572 and 573
Type C - Nonexponsive Soils
Lots
541, 553, 559, 561, 562
567, 577, 582, and 583
It is recommended that the following special design and precautions be taken for the
h
o
u
s
e
s
t
o
be constructed on the above lots in order to minimize the possible damaging effects
d
u
e
t
o
differential movements of the potentially expansive soils:
Type A Lots
Avoid the use of isolated interior piers Use continuous interconnected
reinforced footings throughout, and. place these at a minimum depth of
two feet below the lowest adjacent exterior Final ground surface.
Reinforce and interconnect continuously with steel bars all interior and
exterior Footings with one #5 bar at 3 inches above the bottom of the
footings and one 15 bar placed 1 1/2 inches below the top of the stems
of the footings.
Exercise every effort to assure that the moisture content of the soils in
Mossrivpr R R1 the upper 18 inches below finished grade is 1 percent to 3 percent greater
PRei'i SeiW'e,vr.rc.. than optimum at the time of placing foundations and slabs.
t -Q it ,PeP.
Raised wooden Floors that span between continuous footings are best, or use
concrete slabs with at least 6x6 -10/10 welded wire reinforcement and a
minimum of 4 inches of crushed rock 3/4 to 1 inch in size beneath all
concrete slabs. A moisture barrier should be provided over the crushed rock
and this should be covered with 2 Inches of sand below concrete slabs.
Separate garage slabs from perimeter footings by a 1/2 inch thickness of construction felt or equivalent, to allow independent movement of garage slabs relative to perimeter footings. Assure complete separation by extending
the felt over the full depth of the front thickened edge of !he garage slab. Also, cut off the garage door stops at least 1/2 inch above the slab.
BENTON ENGINEERING. INC.
.24 i71-7-17D -4- October 19, 1972
La Costa Land Company
I
Z40"J
ProvIde positive drafne away from all perimeter footin wIth a
vertical fall of at least 6 inches in a horizontal distance of 5 to
6 Feet outside the house walls.
DA( 77g P , J Prr#f /its, Type B Lots
Than lots listed as Type B lots should follow all the above-listed recommendations with the two
following exceptions:
The continuous footings may be placed at a minimum depth of 18
Inches below the lowest adjacent exterior final ground surface rather
than the two feet recommended for Type A lots.
Single 04 bar placed as directed (above) near tops and bottoms of all
interior and exterior Footings may be substituted for the 05 bars
recommended for Type A lots.
Recommendations 3 to 6, inclusive, as listed for the Type A lots, are also applicable to the
Type B lots.
Only nonexponsive soil conditions were observed in the upper three feet on the Type C lots
and therefore specially designed footings and slabs will not be required on these lots.
Respectfully submitted,
BENTON ENGINEERING, INC.
R. C. Remer
Reviewed by k,-
Philip H. Benkn, Civil Engineer
Distr: (4) Mdressee
(1) Rancho La Costa, Inc.
Attention: Mr. Burton L. Kramer
Rick Engineering Company
San Diego County Building Inspection, Vista Office
(2) Department of County Engineer
(1) Attention: Mr. H. M. Taylor
(1) Attention: Mr..Joe Sovella
(2) City of Carlsbad
Department of Building Inspection RCR/PHB/ew
BENTON ENGINEERING. INC.
LOG.
SAN MABLX)S UNIFIED SCHOOL DISTRICT
PROJECT SERVICE AVAILABILITY LETTER
APPLICANT:JOHtJ N Dc f.1 liA 'rL fl E f2 Phone No. (i i) 43S 4 ZS9
Address: M 2t,24 Owcprhio ,Car LrL CA
OWNER: JbHNJ S OOfJNA flE(2. Phone No._____________
Address: AflE
OJECDESCRIPTION
oject Nam: '7j)fl fl E (2..
oject located on
Assessor's Parcel No.(s):
( Attach legal description
if necessary)
Tract No.
(check one or mere)
E Minor Subdivision (TPM)
17 Major Subdivision (mi)
Project Address/Location 224 Un ibr ii tp
Assessor's Parcel Numbers
1 ME 3.1 I I III I ILD
2.1 I II I I i[:[] 4. I I I II 1 I
Housing Type No. of D.U.'s No. of Bedrocss
Single Family I
Multiple Family
Mobilehome Units
Owner/applicant agrees to reconfirm this project with the issuing school district every 6 months
unless such action is not required by the district. District Phone 619-744-4776
Owner/applicant understand that the certification for school service contained in this Project
Service Availability Letter is no longer effective if the project is disapproved or if the con-
ditional project approval (subdivision, permit, or other conditional use processes) expires.
The information I have provided is correct.
APPLICANT's SIGNATURE i2)bVYfl4.'3YVvn'u2f Date ) f Zd1 I
SAN MAR(XS UNIFIED SCHOOL DISTRICT
CERTIFICATION OF SCHOOL AVAILABILITY OR NON-AVAILABILITY
M: School Districtd& Grades Served:
D School services and facilities are ccnmitted for this project. Services will be available
concurrent with project need based on a secured agreement with the developer which has
adequate financing and clear intent. The termination date of the document is:
See attached copy.
The undersigned school district hereby certifies that it will be able to provide adequate
V school services and facilities to the above described project concurrently with the need of
such project. Owner/applicant has paid the required developer's fee.
The undersigned school district hereby certifies that it will not be able to provide adequate
school services and facilities to the above described project concurrently with the need of
such project because
DISTRICT REPRESENTATIVE'S SIGNATURE itZ%._t.f5 rete_/86:
TITh &/ch,7gi29e_7çii#77
PINK-OWNER/APPLICANT
Jft. 1Ir San Marcos Unified School District
270 Son Marcos Blud., San Marcos, California 92069-2797 619-744-47 76
MEMORANDUM OF AGREEMENT -
REFERENCE: .
We, the owner or agent for the owner of the above-reference.., property,
hereby agree to pay'$ as a fee which will satisfy the
requirements for school facilities dedication of land and fees. In
exchange for this fee, the District will execute the availability form
for the-above-reference property. -
-
John & Donna Sonner
- $2822 -
NAME - AMOUNT RECEIVED
2624 Unicoi-nio -
Cecilia Leonard 8/29/86
STREET BY
Carlsbad, Californj-a.92008 - -
8/29/86
CITY -
DATE
438 4259 - -
TELEPHONE
-
SOMMER CONSTRUCTION - 674
1709 CATALPA PH. 619-438-7366
CARLSBAD, CA 92008 90-7101/3222 -
19c
PAY TOTHE ORDER OF _'74 I $
- A ',I ; / jj _j 6=0 —
cD—,J -' DOLLARS
Great AmericaI' L
I t First Savings Bank
I —I 1443 Encinitas Boulevard
'.. J Encinitas, Calitornla 92024
F0R_2t7-1 -
II20006?i,u--I:3222?L0: OL.I 2 3LG1"
EXHIBIT
LEUCADIA COUNTY WATER DISTRICT
APPLICATION FOR SEWER SERVICE
The application must be signed by the owner (or his representative) of the property to be served. The total
charges must be paid to the District at the time the application is submitted.
APPLICANT MUST SUBMIT EVIDENCE OF BUILDING PERMIT WITHIN 60 DAYS. FAILURE TO MAKE SUCH
SUBMITTAL WILL RESULT IN AUTOMATIC CANCELLATION OF THE SEWER PERMIT. THE SEWER CON-
NECTION FEE LESS A $50 ADMINISTRATIVE FEE WILL BE REFUNDED.
A six-month construction period shall be provided and sewer service charges for the balance of the fiscal year
shall be collected at the time of application for sewer permits. Sewer service charges for subsequent fiscal years
shall be collected on the tax roll in same manner as property taxes. If the six-month construction period extends
into the subsequent fiscal year, a prorated sewer service charge for that fiscal year shall be collected on the tax roll
in the same manner as property taxes. The full sewer service charges for all subsequent years shall be collected on
the tax roll in the same manner as property taxes. There will be no additional fee or refund if service actually com-
mences on a different date.
The prorated sewer service charge shall not be required in those applications for sewer permits for subdivisions.
Such applicants shall be required to notify the District, on forms provided by the District, of escrow closing on
individual properties within the subdivision. Sewer service charges shall commence upon close of escrow and will
be the responsibility of the buyer.
If a service lateral is required, it will be installed by the LEUCADIA COUNTY WATER DISTRICT. The service
lateral is that part of the sewer system that extends from the main collection line in the street (or easement) to the
point in the street (at or near the applicant's property line) where the service lateral is connected to the applicant's
building sewer. The applicant is responsible for the construction, at the applicant's expense, of the sewer pipeline
(building sewer) from the applicant's plumbing to the point in the street (or easement) where a connection is made
to the service lateral.
The connection of the applicant's building sewer to the service lateral shall be made by the applicant at his
expense. The connection must be made in conformity with the District's specifications, rules and regulations; and
IT MUST BE INSPECTED AND APPROVED BY THE DISTRICT BEFORE THE SEWER SYSTEM MAY BE USED BY
THE APPLICANT. THE APPLICANT, OR HIS AUTHORIZED REPRESENTATIVE MUST NOTIFY THE DISTRICT AT
THE TIME INSPECTION IS DESIRED. ANY CONNECTION MADE TO THE SERVICE LATERAL OR COLLECTION
LINE WITHOUT PRIOR APPROVAL AND INSPECTION BY THE DISTRICT WILL BE CONSIDERED INVALID AND
WILL NOT BE ACKNOWLEDGED.
In the event unusual construction conditions occur, such as blasting, jack hammering hard rock, dewatering,
etc., the applicant shall be liable for any cost over and above the established charge.
The Inspection Deposit will be refunded upon the completion of satisfactory inspection of the connection to
the District's sewer system. The Inspection Deposit shall not apply in those cases in which the applicant has paid
plan check and inspection fees for a subdivision.
OWNER'S NAME_John Sommer
MAILING ADDRESS: 1709 Catalpa Road
Carlsbad.. Ca. 92008
PHONE NUMBER:_____________________
SERVICEADDRESS: 2624 Llnicnrnio Street
TRACTNAME/NO. L.C..M. # 3 LOT#_470
ASSESSOR'S PARCEL NO.: 215-3511-46
TYPE OFBUILDING SF0 NO./UNITS_1
CONNECTION FEE: $
LATERAL SIZE:_____
EXTRA FOOTAGE: @ $ lFoot_______
EXTRA DEPTH: @$ /Foot_________
LATERAL FEE___________________________
INSPECTION DEPOSIT $ 50.00
PRORATED SEWER SERV. FEE 57.00
TOTAL $107.00
PAID BY: CASH CHECK#_656
The undersigned hereby agrees that the above information given is correct and agrees to the conditions as
Supple. to
7-16-86 W. Roehl 9823
Owner Date Rec'd. By Account No.
A)
LEUCADIA COUNTY WATER DISTRICT
APPLICATION FOR SEWER SERVICE
Owner's Name Julio._A. Land.oni Phone No. 481-9839
Mailing Address l3547_ Mango Qda__
Set-vice Address: Ilni cania.S.tte.e.L_.
Tract Description: _lot 47n, wc
Assessor's Parcel No. iccn-4
Type of Building Si nqle Emily No. Units i Connection Fee $600.00
Lateral Size: 4" - 6" - 8" Saddle - Easement Connection (pre-pd 200.00)
@ $
Lateral Fee
Prorated Sewer
Service Fee
Total $1c0.oO
Extra Footage: @ $________ Extra Depth:
Amount Rec'd
Ck. No/Cash .
Date 8c9
Rec'd By
The application must be signed by the
the property to be served. The total
time the application, is submitted.
owner (or his authorized representative) of
charges must be paid to the District at the
If a service lateral is required, it will be installed by the Leucadia County Water
District. The service lateral is that part of the sewer system that extends from
the main collection line in the street (or easement) to the point in the street (at
or near the applicant's property line) where the service lateral is connected to
the applicant's building sewer. The applicant is responsible for the construction,
at the applicant's expense ofthésewer pipeline (building sewer) from the appli-
cant's plumbing to the point in. the street (or easement) where a connection is made
to the service lateral.
The connection of the applicant's building sewer to the service lateral shall be
made by the applicant at his expense. The connection must be made in conformity
with the District's specifications, rules and regulations; and IT MUST BE INSPECTED
AND APPROVED BY THE DISTRICT BEFORE THE SEWER SYSTEM MAY BE USED BY THE APPLICANT.
THE APPLICANT, OR HIS AUTHORIZED REPRESENTATIVE, MUST NOTIFY THE DISTRICT AT THE
TIME INSPECTION IS DESIRED. ANY CONNECTION MADE TO THE SERVICE LATERAL OR COLLEC-
TION LINE WITHOUT PRIOR APPROVAL AND INSPECTION BY THE DISTRICT WILL BE CONSIDERED
INVALID AND WILL NOT BE ACKNOWLEDGED.
The prorated sewer service fee is based upon the date the District estimates that
service will begin and covers the balance of the fiscal year. There will be no
additional fee or refund if service actually commences on a different date. For
succeeding fiscal years, the sewer service fee will be collected on the tax roll
in the same manner as property taxes.
The undersigned hereby agrees that the above information given is correct and agrees
to the conditions as stated. .
Su 'c, Ii
.i/ /I.Il4k A&4;. 2? '7?. D//2— Qt '4
/ Owner's Signature Date Account No.