HomeMy WebLinkAbout2740 UNICORNIO ST; ; CB031096; Permit• City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
08-14-2003 Residential Permit Permit No: CB031096
Building Inspection Request Line (760) 602-2725
Job Address: 2740 UNICORNIO ST CBAD
Permit Type: RESDNTL Sub Type: RAD Status: ISSUED
Parcel No: 2153505700 Lot #: 0 Applied: 04/16/2003
Valuation: $49,266.00 Construction Type: NEW Entered By: MDP
Occupancy Group: Reference #: Plan Approved: 08/14/2003
# Dwelling Units: 0 Structure Type: Issued: 08/14/2003
Bedrooms: 0 Bathrooms: 0 Inspect Area:
Project Title: HACKER RESIDENCE Orig PC#:
483 SF ADDITION Plan Check#:
Applicant:
FAULKNER ALEX
STE 117
2120 JIMMY DURANTE
DEL MAR 92014
Owner:
LA COSTA INDUSTRIES CORP
6965 EL CAMINO REAL #105-419
CARLSBAD CA 92009
Building Permit $354.19 Meter Size
Add'I Building Permit Fee $0.00 Add'I Red. Water Con. Fee $0.00
Plan Check $230.22 Meter Fee $0.00
Add'I Plan Check Fee $0.00 SDCWA Fee $0.00
Plan Check Discount $0.00 CFD Payoff Fee $0.00
Strong Motion Fee $4.93 PFF $0.00
Park in Lieu Fee $0.00 PFF (CFD Fund) $0.00
Park Fee $0.00 License Tax $0.00
LFM Fee $0.00 License Tax (CFD Fund) $0.00
Bridge Fee $0.00 Traffic Impact Fee - $0.00
Other Bridge Fee $0.00 Traffic Impact (CFD Fund) $0.00
BTD #2 Fee $0.00 Sidewalk Fee $0.00
BTD #3 Fee $0.00 PLUMBING TOTAL $83.00
Renewal Fee $0.00 ELECTRICAL TOTAL $20.00
Add'I Renewal Fee $0.00 MECHANICAL TOTAL $24.00
Other Building Fee $0.00 Housing Impact Fee $0.00
Pot. Water Con. Fee $0.00 Housing InLieu Fee $0.00
Meter Size Housing Credit Fee $0.00
Add'I Pot. Water Con. Fee $0.00 Master Drainage Fee $0.00
Red. Water Con. Fee $0.00 - Sewer Fee $0.00
Additional Fees $0.00
TOTAL PERMIT FEES $716.34
Total Fees: $716.34 Total Payments To Date: $230.22 Balance Due: $486.12
2000 08/14/03 0002 01 iv,
COP 4B6.12
FINAL APPAOX/AL
Inspector: Date: ().( 't7 Clearance:
NOTICE: Please take NOTICE that approval of your project includes the Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as fees/exactions. You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has oreviously otherwise expired.
O~ERIVIIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008
FOR OFFICE USE ONLY
PLAN CHECK NO. (C')3
VAL.i ? tiC Plan Ck. Deposit #1j b
Validated By ,
Z 7O r,ccpT,ô 9 -' Address (include Bldg/Suite #) Business Name (at this addrsY' ,4i .ô' 03 000g. vi 02
/ C63yI& MI5 .3 . COP I 230-22
Legal Descri tion Lot No. Subdivision Name/Number Unit No. Phase No. Total # of units
i -57 S'fD 10
Assessor's Parcel # Existing Use Propospd Use
EDiLDM /&0d //1FAP z
Description of Work SQ. FT. #of Stories # of Bedrooms # of Bathrooms
Kirzotc!L&j4g 8 L._._____ 2' * -
i&L6W 7ILA-e.
Name Address City State/Zip Telephone # Fax #
,h./4)( JlJrJ* 2126 JIff/' Dufl17 6i/7 DL ..t4 '1A72c71{ 'fc /
Name Address City state/Z Telephone #
Name Address - City / state/Zip Telephone #
1 COjI 1'PCOMPNL L
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
(Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundre,dollars ($50011.
ch-q-Cor S -
Name Address City LState/Zip elép ne
State License # &('z_''i Y' License Class ________________ City Business License #
Designer Name Address City State/Zip Telephone
State License
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
F have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My worker's compensation insurance carrier and policy number are: -
Insurance Company ________________________________________________ Policy No. Expiration Date__________________
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($1001 OR LESS)
CERTIFICATE OF MR . I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
/to become subject t the rkers' C mpensation Laws of California.
ARNING: Failur to se r' workerL' tion coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dol are I 00,0 In ad i# to the damages as provided for In Sectio 3706 of the LAO c,9. ierest and attorney's fees.
SIGNATURE____________________________________________________________ DATE e9
7OWNER ILDER DecRAT BU ION: :TTT
I heieby affirm that I am exempt from the Contractor's License Law for the following reason:
I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
I am exempt under Section _______________ Business and Professions Code for this reason:
I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ONO
I (have / have not) signed an application for a building permit for the proposed work.
I have contracted with the following person (firm)-to provide the proposed construction (include name / address / phone number) contractors license number):
I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address / phone
number / contractors license number): - -
I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of work): -
PROPERTY OWNER SIGNATURE DATE
T
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner HazardoUs Substance Account Act? 0 YES 0 NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES 0 NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES 0 NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. -
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 30970) Civil Code).
LENDER'S NAME LENDER'S ADDRESS_______________________________________________________
APPLICANT Ccrjoj: -- ------- ---
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citi of Carlsbad to enter Upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'O" ep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the building Off ici nder the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is not comm within 11800hysipirn the date of such permit or if the building or work authorized by such permit is suspended or abandoned
at any time after the work is comm ced for a period j6fjAnays (Sectiàn 106.4.4 Uniform Building Code).
APPLICANT'S SIGNATURE ' DTE Z,6 '03
WHITE: File YELLOW: Applicant PINK: Finance -
List 1- Permit-Type
From the following list, determine the permit-type that best describes the work you propose to do. Please put the code of that
permit-type in the blank at the top of the page on the front of this application. Residential permits (only) also require the
identification of the structure-type to be associated with the permit. Choose a structure-type from 'List 2 - Structure-Types' and put
its code in the appropriate blank on the front of this application.
Residential Permits
Code Description
APT Apartments . new construction.
CONDO Condominiums - new construction.
CVNNR Conversion. Convert all or a portion of a non-residential building to residential use, creating one or more new
residential units.
CVNRN Conversion. Convert one or more residences in a building to non-residential usage.
CVNRR Conversion. Increase or reduce the number of dwelling units in a residential structure through interior modifications
(i.e.: a four bedroom house converted to a duplex, with 2 bedrooms each).
DEMO Demolition permit. (Also specify type of structure from List 2).
DUP Duplex - new construction.
MOHO Mobile home, renovation, repair, or addition of accessory structure not yielding a new living unit.
MOHON Mobile home, pre-fabricated house, or trailer installed (plumbed, wired) in a mobile home park (see distinction from
single-family residence, below).
RAD Residential addition/alteration, creating no new dwelling unit(s).
RREISSUE Residential permit re-issue.
RREPAIR Residential building repair. Damage, fire, etc.
RREPLACE Residential building replacement (no additional units).
SFA Single-family, attached - new construction. A one-family house attached to one or more other houses, with one or
more common walls extending from foundation to roof at, or forming, a lot line. Has own plumbing and heating
system (e.g.: townhouse, row house, half-plex)
SFD Single-family, detached - new construction: A one-family house with open area on all four sides. May have an
attached or detached garage, or a business. May be a detached "granny flat'. May be a mobile home or trailer on an
individual lot, but not in a mobile home park.
Non-Residential/Accessory Permits
Code Description
COM Commercial structure, new construction.
CREISSUE Commercial permit re-issue.
CREPAIR Commercial building - repair. Damage, fire, etc.
CREPLACE Commercial building - replacement.
Cli Commercial tenant improvement.
DEMO Demolition permit.
ELEC Electrical permit, for electrical work only.
HOTEL Hotel or motel (including Managed Living Unit hotel) - new construction.
HOTELR Hotel renovation.
INDUST Industrial structure, new construction.
Ill Industrial tenant improvement.
MECH Mechanical permit, for mechanical work only.
MISC Miscellaneous. Use only if proposed work doesn't fit another activity type.
PATIO Patio and/or deck.
PLUM Plumbing permit, for plumbing work only.
POOL Gunite pools and spas.
RETAIN Retaining wall permit.
SIGN Sign construction/installation permit.
SOLAR Solar energy system installation permit (specify structure type to be served).
SPA Factory-made or Gunite.
List 2 - Structure-Type (Use with Residential Permit Only)
From the following list, determine the type of resideiial structure that best describé the structure on which you will be working.
Please put the code of that structure-type in the appropriate blank at the top of the page on the front of this application.
Code Description
SFA Single-family, attached. A one-family house attached to one or more other houses, with one or more common walls
extending from foundation to roof at, or forming, a lot line. Has own plumbing and heating system (e.g.: townhouse,
row house, half-plex).
SFD Single-family detached: A one-family house with open area on all four sides. May have an attached or detached
garage, or a business. May be a detached 'granny flat'. May be a mobile home or trailer on an individual lot, but not
in a mobile home park.
MF2-4 Multi-family, 2 to 4 units. A residential structure on a single lot, containing two, three, or four dwelling units. Units
may share master heating, plumbing, or electrical service (e.g.: duplex, triple; quad-plex).
MF5 + Multi-family, 5 or more units. Same as MF2-4, except the building has a t least five attached units on the same lot.
MOHO Mobile home, pre-fabricated house, or trailer installed (plumbed, wired) in a mobile home park (see distinction from
single-family residence, above).
City of Carlsbad Bldg Inspection Request
For: 12/05/2003
Permit# CB031096
Title: HACKER RES-483 SF ADDITION,NEW
Description: 200 AMP ELECT PANEL
Type: RESDNTL Sub Type: RAD
Job Address: 2740 UNICORNIO ST
Suite: Lot 0
Location:
APPLICANT FAULKNER ALEX
Owner: LA COSTA INDUSTRIES CORP
Remarks:
Total Time:
Inspector Assignment: JM
Phone: 7608157256
Inspector:
Requested By: NA
Entered By: CHRISTINE
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
,domment
T
Associated PCRs/CVs
PCR03180 ISSUED HACKER RES REV BATH ADDITION; REDUCING BDRM
Inspection History L6~ Date Description
11/14/2003 18 Exterior Lath/Drywall
10/17/2003 17 Interior Lath/Drywall
10/16/2003 17 Interior Lath/Drywall
10/15/2003 17 Interior Lath/Drywall
10/14/2003 16 Insulation
10/10/2003 16 Insulation
10/10/2003 33 Service Change/Upgrade
10/06/2003 84 Rough Combo
10/03/2003 84 Rough Combo
09/15/2003 13 Shear Panels/HD's
09/12/2003 13 Shear Panels/HD's
09/10/2003 13 Shear Panels/HD's
09/09/2003 13 Shear Panels/HD's
08/21/2003 11 Ftg/Foundation/Piers
Act Insp Comments
- AP JM NO RECORD CARD
AP JM (fl BATH LATH OK
AP JM i LATH OK
CA JM (,iL 4
AP JM OK TO DWALL
NH JM
NH JM
AP JM OK TO INSULATE ENTIRE HOUSE PICKUP @ INSUL.
CA TP
CO JM ADD AB S, A35 S & SILL NAILING
CA JM BY ROBERT
CA JM
CA JM CANCEL BY CONTRACTOR
AP JM OK TO POUR ALL PAD & FOUNDATION
CONSTRUC'TIONTESTING'&ENGINEERING, INC.
ESCONDIDO • TRACY • CORONA. OXNARD • LANCASTER • SACRAMENTO
ENGINEERING, INC. INSPECTION REPORT PAGE 10F I
CTE JOB #
REPORT ii
PROJECTNAME: ck..e INSPECTION MATERIAL IDENTIFICATION
ADDRESS:
2AsS6AP c..4
ARCHITECT: . A ew C #-, -
ENGINEER:
CONTRACTOR: C#s'rc £4,'4 5-rLc..77o,4
INSPECTION DATE: 3
PLAN FILE:
()CONCRETE CONC.MIx#/ISI________________
()MASONRY GROUT MIX#/PSI_________________
( ) P.T. CONC. MORTAR TYPE/PSI_______________
( ) FIELD WELD
REBAR GRADE_________________
()SHOP WELDING
STR. STEEL_____________________ ()PILE DRIVING '-[s_BOLT )BATCH PLANT
BLDG. PERMIT: C.-& 03 10 i 4e (i)P. ANCHOR MAS. BLOCK
OTHER: . •. {( ) OTHER ELECTRODE
MATERIAL SAMPLING'
()CONCRETE ()MORTAR ()GROUT ()FIREPROOFING ()MASONRY BLOCK ()REBAR
()STRUCTURAL STEEL () BOLTS - - -
INSPECTION PERFORMED, JOB PROBLEM, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REMARKS
—C8.,-r-I.ao 0..S ,d Cc..'icj, r!4 C CP 0 or
/2" . 4 . . rs ? 4 -F C. I4-' .. 36 I') .(.
L c)77 -c — -p-p
.,fc S -' -- _
',f
,ç1W '-'c'r CPTh C-&.C.".
4 4'2... C , A (
, i-c' 4 I M i. -rA 'C
'r 2--e 9=0W qd 49 * s c. -ir.., , C. i.i c
Certification of Compliance: All work, unless otherwise noted, complies with the approved plans and specifications and
the uniform building code. - -j
NAME: (PRINT) /"- SIGN
CERTIFICATION NO: ' ' '5 0 42- Z- (4' '
2414 VINYARD AVENUE, SUITE G ESCONDIDO, CA 92029 (760) 746-4955 FAX (760) 746-9806
EsGil Corporation
In cPartnersliip with government for Bui(dIng Safety
DATE: 06/20/03 ANT
JURISDICTION: Carlsbad U PLAN REVIEWER
U FILE
PLAN CHECK NO.: 03-1096 SET: III
PROJECT ADDRESS: 2740 Unicornio
PROJECT NAME: Addition/ Remodel for Hacker Residence
F] The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
LI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
R Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: ) Fax #:
Mail Telephone Fax In Person
REMARKS: Note on cover sheet that special inspection required for retro fit bolts.
By: Ray Fuller Enclosures:
Esgil Corporation
0 GA 0 MB 0 EJ 0 PC 06/16/03 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576
EsGil Corporation
In (Partners/lip wit/i government for(Building Safety
DATE: 06/06/03
JURISDICTION: Carlsbad
PLAN CHECK NO.: 03-1096
PROJECT ADDRESS: 2740 Unicornio
SET:-1l
OAPPUT
Qy-)
O PLAN REVIEWER
U FILE
PROJECT NAME: Addition/ Remodel for Hacker Residence
Eli The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
Eill The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
LII The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Alex Faulkner
2120 Jimmy Durnate #117 Del Mar, Ca. 92014
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Alex Faulkner (sj . Telephone # (858) 481-1819
Date contacted: G f to (03 (by: (c.) Fax #:
Mail L-'lephone -' Fax In Person
[1 REMARKS:
By: Ray Fuller Enclosures:
Esgil Corporation
0 GA 0 MB D EJ 0 PC 05/30/03 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576
Carlsbad 03-1096
06/06/03
RECHECK PLAN CORRECTION LIST
JURISDICTION: Carlsbad
PROJECT ADDRESS: 2740 Unicornio
DATE PLAN RECEIVED BY.
ESGIL CORPORATION: 05/30/03
REVIEWED BY: Ray Fuller
FOREWORD (PLEASE READ):
PLAN CHECK NO.: 03-1096
SET: II
DATE RECHECK COMPLETED:
06/06/03
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and disabled access. This plan review is
based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law. . . . .
To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans.
The following items have not been resolved from the previous plan reviews. The original
correction number has been given for your reference. In case you did not keep a copy of
the prior correction list, we have enclosed those pages containing the outstanding
corrections. Please contact me if you have any questions regarding these items.
Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and where
they are located on the plans. Have changes been made not resulting from this list?
DYes UNo
Carlsbad 03-1096
06/06/03
The items listed below are from the previous list. These remaining items have not been
adequately addressed. The remarks in bold are to emphasize the remaining problem.
1. Please make all corrections on the original tracings, as requested in the correction list.
Submit three sets of plans for commercial/industrial projects (two sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted in one of
two ways:
Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92009, (760) 602-2700.
The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering
and Fire Departments.
Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad Building
Department for routing to their Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by EsGil
Corporation is complete.
2. Final sets of plans and any new calculations to be stamped and signed by engineer and
/or architect of record also.
Could not locate how study on A-3 is being provided with light and ventilation. Still
applies. Have reviewed the plans my supervisor on this issue and light and
ventilation requirements are not being meant as proposed.
All bedroom branch circuits now require arc fault protection. Note clearly on the plans
that "Bedroom branch circuits will be arc fault circuit protected." NEC Art. 210-12(b).
Electrical note 3 on sheet A-I concerns bath circuits and does not appear to
address the Arc Fault requirements in bedrooms.
13. Detail and reference any retro fit anchor bolts to be required at existing foundation with
proposed new shear walls. City requires special inspection for any retro fit shear or
hold bolts. Please complete attached form.
To speedup the review process, note on this list (or a copy) where each. correction item
has been addressed, i.e., plan sheet, note or detail number, calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and
where they are located in the plans.
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform
the plan review for your project. If you have any questions regarding these plan review
items, please contact Ray Fuller at Esgil Corporation. Thank you.
Signed
A.
I
Crisbd 03-1096
06/06/03
,ISPECIAL INSPECTION PROGRAM
ADDRESS OR LEGAL DESCRIPTION: 2 J, tqii
PLAN CHECK NUMBER: 03 J07, OWNER'S NAME: LJOL7 /,LA. -.sp
I, as the owner, or agent of the owner (contractors may not employ the special inspector), certify that I, or the
architect/engineer of record, will be responsible for employing the special inspector(s) as required by Uniform
Building Code (UBC) Section 1701.1 for the construction project located at the site listed above. UBC Section
106.3.5. /
I, as the engineer/architect of record, certify that I have prepared the following special inspection program as required by UBC
Section 106.3.5 for the construction project located at the site listed above.
Engineer's/Architect's
A.
0. C-15737
Seal
ed
OF CALN,~
Sign
1. List of work requiring special inspection:
O Soils Compliance Prior to Foundation Inspection
O Structural Concrete Over 2500 PSI 0
O Prestressed Concrete
O Structural Masonry
O Designer Specified
& Signature Here
O Field Welding
High Strength Bolting
.Expansion/Epoxy Anchors
O Sprayed-On Fireproofing
E] Other
Name(s) of individual(s) or firm(s) responsible for the special inspections listed above:
A. eAZU /4V 2&0
Duties of the special inspectors for the work listed above:
57'Y
Special inspectors shall check in with the City and present their credentials for approval prior to beginning work on
the job site.
EsGil Corporation
In (Partnership wit/i government for (Building Safety
DATE: 04/24/03
JURISDICTION: Carlsbad
PLAN CHECK NO.: 03-1096
PROJECT ADDRESS: 2740 Unicornio
SET:I
O AP LICANT
JURIS
U PLAN REVIEWER
O FILE
PROJECT NAME: Addition/ Remodel for Hacker Residence
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
LI The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held -at Esgil
Corporation until corrected plans are submitted for recheck.
LI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Alex Faulkner
2120 Jimmy Durnate #117 Del Mar, Ca. 92014
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Alex Faulkner (.j .,) Telephone #: (858) 481-1819
Date contacted: ' Ii- /03(by: ( ) Fax #:
Mail 'v/Telephone. Fax In Person
LI REMARKS:
By: Ray Fuller Enclosures:
Esgil Corporation
0 GA 0 MB 0 EJ 0 PC 04/17/03 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 • San Diego, California 02123 • (858) 560-1468 • Fax (858) 560-1576
Carlsbad 03-1096
04/24/03
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
JURISDICTION: Carlsbad PLAN CHECK NO.: 03-1096
PROJECT ADDRESS: 2740 Unicornio
FLOOR AREA:
Addition 483
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 04/16/03
DATE INITIAL PLAN REVIEW
COMPLETED: 04/24/03
STORIES: 2
HEIGHT: 20 ft per UBC
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 04/17/03
PLAN REVIEWER: Ray Fuller
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinance by the Planning Department, Engineering Department, Fire
Department or other departments. Clearance from those departments may be required prior to
the issuance of a building permit.
Present California law mandates that residential construction comply with the 2001 edition of
the California Building .Code (Title 24), which adopts the following model codes: 1997 UBC,
2000 UPC, 2000 UMC and 1999 NEC (all effective 11/1/02).
The above regulations apply to residential construction, regardless of the code editions adopted
by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section. etc.
Be sure to enclose the marked up list when you submit the revised plans.
Carlsbad 03-1096
04/24/03
. PLANS
1. Please make all corrections on the original tracings, as requested in the correction
list.
Submit three sets of plans for commercial/industrial projects (two sets of plans for
residential projects). For expeditious processing, corrected sets .can be submitted
in one of two ways:
Deliver all corrected sets of plans and calculations/reports directly to the
City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92009,
(760) 602-2700. The City will route the plans to EsGil Corporation and the
Carlsbad Planning, -Engineering and Fire Departments.
Bring one corrected set of plans and calculations/reports to EsGil
Corporation; 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858)
560-1468. Deliver all remaining sets of plans and calculations/reports directly to
the City of Carlsbad Building Department for routing to their Planning, Engineering
and Fire Departments.
NOTE Plans that. are submitted directly to EsGil Corporation only will not
be reviewed by the City Planning, Engineering and Fire Departments until review
by EsGil Corporation is complete.
Final sets of plans and any new calculations to be stamped and signed by
engineer and /or architect of record also.
Not enough information provided to complete plan check.
Provide elevations to reflect proposed and existing work.
Provide cross sections to reflect extend of proposed and existing work.
Provide shear transfer details and expand shear schedule to include transfer i.e.
sill plate nailing, anchor bolt spacing and top plate transfer i.e. A-35's.
Various areas are shown without shear either existing or proposed. See on S-2
at rear of expanded bedroom, bathroom extension, new interior walls to replace
removed walls, detail 4/S-2 where appears to be cripple wall framing below new
shear walls, etc.
Type of existing shear and length not noted for example at expanded bedroom
on S-2.
Could not locate rise and run for new stairs and guard rail details.
Could not locate how study on A-3 is being provided with light and ventilation.
All bedroom branch circuits now require arc fault protection. Note clearly on the
plans that "Bedroom branch circuits will be arc fault. circuit protected." NEC Art.
210-12(b).
Carlsbad 03-1096
04/24/03
Specify connection from existing top plates to new i.e. some type of strap.
Provide Strong Wall details and reference to the plans. Show deepen footings for
minimum 25" embedment required for the SST1328's with additional 3" clearance
required below the bolts.
Detail and reference any retro fit anchor bolts to be required at existing
foundation with proposed new shear walls.
Owner/designer to sign the CFI -R forms.
Detail and reference all shear to roof sheathing to include edge nailing of roof
diaphragm to members below.
Cross sections to be provided to reflect insulation.
To speed up the review process, note on this list (or a copy) where each correction
item has been addressed, i.e., plan sheet, note or detail number, calculation page,
etc.
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly describe
them and where they are located in the plans.
Have changes been made to the plans not resulting from this correction list? Please
indicate:
Yes L3 No L3
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468,
to perform the plan review for your project. If you have any questions regarding
these plan review items, please contact Ray Fuller at Esgil Corporation. Thank
you.
Carlsbad 03-1096
04/24/03
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK NO.: 03-1096
PREPARED BY: Ray Fuller DATE: 04/24/03
BUILDING ADDRESS: 2740 Unicornio
BUILDING OCCUPANCY: R3 TYPE OF CONSTRUCTION: VN
BUILDING
PORTION
AREA
(Sq. Ft.)
..
Valuation
Multiplier r Reg.
Mod. r VALUE ($)
Addition 483 Per City Est. 49,266
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code ICB IBY Ordinance
Bldg. Permit Fee by Ordinance 1j
$345.061
Plan Check Fee by Ordinance. V
I $224.29
Type of Review: J Complete Review D Structural Only
0 Repetitive Fee
D Other
Repeats Hourly Hour *
Esgil Plan Review Fee I $193.231
Comments:
Sheet lof 1.
macvalue.doc
BUILDING PLANCHECK CHECKLIST
.PLANCHECK NO.: CB
BUILDING AbDRSS:. cL7( \ ccr rvnD
PROJECT DESCRIPTION:
ASSESSOR'S PARCEL NUMBER: EST. VALUE:
ENGINEERING DEPARTMENT
APPROVAL
The item you have submitted for, review has been
approved. The approval is based on plans,
information and/or specifications provided in your
submittal; therefore any changes to these items after
this date, including field modifications, must be
reviewed by this office to insure continued
conformance with applicable codeè. Please review
carefully all comments attached, as failure to comply
with instructions in this report can result in
suspension of permit to build.
A Right-of-Way permit is required prior to
construction of the following improvements:
DENIAL
Please see the attached report of deficiencies
marked with 0. Make necessary corrections to plans
or specifications for compliance with applicable
odes and standards. Submit corrected plans and/or
specifications to this office for review.
By:
By:'
By:
Date:
Date:
Date: -
Dedication Application
Dedication Checklist
Improvement Application
Improvement Checklist
Future Improvement Agreement
Grading Permit Application
Grading Submittal Checklist
Right-of-Way Permit Application
Riht-of-Way Permit Submittal Checklist
and Information Sheet
Sewer Fee hformation Sheet
HWORDiDOCSCHSTWUI PIaniedc Cldst Form (Geneft).doc
City of Carlsbad
Address: 1635 Faraday Avenue, Carlsbad, CA 92008
Phone: (760) 602-2775
CFD INFORMATION
Parcel Map No:
Lots:
Recordation:.
Carlsbad Tract:
A-4
I Rev. 7114100
A. North Arrow F. Right-of-Way-Width & Adjacent Streets
B. Existing & Proposed Structures G. Driveway widths
C. Existing Street Improvements H. Existing or proposed sewer lateral
D. Property Lines I. Existing or proposed water service
E. Easements J. Existing or proposed irrigation service
2. Show on site plan:
BUILDING PLANCHECK CHECKLIST
ND 1 ST 3RD /2~ o
SITE PLAN
1. Provide a fully dimensioned site plan drawn to scale. Show:
A. Drainage Patterns
Building pad surface drainage must maintain a minimum slope of one
percent towards an adjoining street or an approved drainage course.
ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive
drainage of 2% to swale 5' away from building."
B. Existing & Proposed Slopes and Topography
C. Size, type, location, alignment of existing or proposed sewer and water service
(s) that serves the project. Each unit requires a separate service, however,
second dwelling units and apartment complexes are an exception.
D. Sewer and water laterals should not be located within proposed driveways, per
standards.
3. Include on title sheet:
Site address
Assessor's Parcel Number
Legal Description
For commercial/industrial buildings and tenant improvement projects, include:
total building square footage with the square footage for each different use,
existing sewer permits showing square footage of different uses (manufacturing,
warehouse, office, etc.) previously approved.
EXISTING PERMIT NUMBER DESCRIPTION
H:WORDDOCSCHKLSflBuJIdng Pandiedi Cidsi Fans (Geneflc).dac 2 Rev. 7114100
BUILDING PLANCHECK CHECKLIST
1ST 2ND 3rd DISCRETIONARY APPROVAL COMPLIANCE
0 0 4a. Project does not comply with the following Engineering Conditions' of approval for
ProjectNo._______________________________________________________
0 0 0 4b. All conditions are in compliance. Date:
DEDICATION REQUIREMENTS
At/uk 0 0 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm
P ' drain or utility easements on the building site is required for all new buildings and
-for remodels with a value at or exceeding $15.000, pursuant to Carlsbad
Municipal Code Section 18.40.030.
Dedication required as follows:
Dedication required. Please have a registered Civil Engineer or Land Surveyor
prepare the appropriate legal description together with an 8 1/ x 11" plat map
and submit with a title report. All easement documents must be approved and
signed by owner(s) prior to issuance of Building Permit. Attached please find an
application form and submittal checklist for the dedication process. Submit the
completed application form with the required checklist items and fees to the
Engineering Department in rperson. Applications will not be accept by mail or fax.
Dedication completed by: Date:
IMPROVEMENT REQUIREMENTS
0 0 0 6a. All needed public improvements upon and adjacent to the building site must be
constructed at time of building construction whenever the value of the
construction exceeds $75.000, pursuant to Carlsbad Municipal Code Section•
18.40.040.
Public improvements required as follows:
Attached please find an application form and submittal checklist for the public
improvement requirements. A registered Civil Engineer must prepare the
appropriate improvement• plans and submit them together with the requirements
on the attached checklist to the Engineering Department through a separate plan
check process. The completed application form and the requirements on the
H:tWORDDOcSCHKLST%BUiJding Planchedi Cklst Form (RIDDLE. HARVEY 7.1240).doc 3 Rev. 12120198
tj
BUILDING PLANCHECK CHECKLIST
el
checklist must be submitted in person. Applications by mail or fax are not
accepted. Improvement plans must be approved, appropriate securities posted
and 'fees paid prior to issuance of building permit.
Improvement Plans signed by: Date:
1ST 2N0 3RD
)
El El El 6b. Construction of the public improvements may be deferred pursuant to Carlsbad
Municipal Code Section 18.40. Please submit a recent property.title report or
current grant deed on the property and processing fee of $310 so we may
prepare the necessary Future Improvement Agreement. This, agreement must be
'signed, notarized and approved by the City prior to issuance of 'a Building permit.
Future public improvements required as follows:•• .
El 0 0 6c.. Enclosed please find your Future Improvement Agreement. Please return
'agreement signed and notarized to the Engineering Department.
Future Improvement Agreement completed by:.
Date:
F1 0 0 6d. No' Public Improvements required., SPECIAL NOTE: Damaged or defective.
improvements found adiacent to building site must be repaired to the satisfaction,
of the City Inspector prior to occupancy.
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for, a grading permit are found in Section
11.06.030 of the Municipal Code.
0 0 0 7a Inadequate information available on Site Plan to make a determination' on grading
requirements. Include accurate grading quantities (cut, fill import, export).
0 El El 7b. Grading Permit required. A separate grading plan prepared by a registered Civil
Engineer must be submitted together with the completed application form
attached. NOTE: The. Grading Permit must be issued and rough grading
. approval obtained prior to issuance of a Building Permit.
Grading Inspector sign off by: Date:
El ' El El. 7c. Graded Pad Certification required. (Note: Pad certification may be required even
if a grading permit is not required.)
HWORDOOCSCHKLSTWui?difl9 Plancheck Cidsi Form (Generic 7.I4.)4c 4 Rev. 7114100
BUILDING PLANCHECK CHECKLIST
1 4_/'; 3RD
E1 0 0 7d .No Grading Permit required.
0 0 0 7e. If grading is not required, write "No Grading" on plot plan.
MISCELLANEOUS PERMITS
0 0 8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or.
private work adjacent to the public Right-of-Way. Types of work include, but are.
not limited to: street improvements, tree trimming, driveway construction, tying
into, public storm drain, sewer and water utilities.
Right-of-Way permit required for:
0 0 9. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad
sewer service area, you need to contact the Carlsbad Municipal Water District,
located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can
provide forms and assistance, and will check to see if your business enterprise is
on the EWA Exempt List. You may telephone (760) 438-2722, extension 7153,
for assistance.
Industrial Waste permit accepted by: .
Date:
0 0 10. NPDES PERMIT .
Complies with the City's requirements of the National Pollutant Discharge
Elimination System (NPDES) permit. The applicant shall provide best
management practices to reduce surface pollutants to an acceptable level prior to
discharge to sensitive areas. Plans for such improvements shall be approved by
the City Engineer prior to issuance of grading or building permit, whichever
occurs first.
0 0 11. ~eq redfeesareattached
No fees required
WATER METER REVIEW
1ith( 0 0 12a. Domestic (potable) Use r Ensure that the meter proposed by the owner/developeri is not oversized.
Oversized meters are inaccurate during low-flow conditions. If it is oversized, for
the life of the meter, the City will not accurately bill the owner for the water used.
All single family dwelling units received "standard" 1" service with 5/8" service.
I
HWORDDOCS'.cHKLSflBuICIl9 Planchedc Cklst Form (GenerIc4oc 5 Rev. 7114100
BUILDING PLANCHECK CHECKLIST
1ST 2ND 3RD
If owner/developer proposes a size other than the "standard", then
owner/developer must provide potable water demand àalculations,
which include total fixture counts and maximum water demand in gallons
per minute (gpm). A typical fixture count and water demand worksheet is
attached. Once the gpm is provided, check against the "meter sizing
schedule" to verify the anticipated meter size for the unit.
Maximum service and meter size is a 2" service with a 2" meter.
If a developer is proposing a meter greater than 2", suggest the
installation of multiple 2" services as needed to provide the anticipated
demand. (manifolds are considered on case by case basis to limit
multiple trenching into the street).
D 0 12b. Irrigation Use (where recycled water is not available)
I" All irrigation meters must be sized via, irrigation calculations (in gpm) prior
to approval. The developer must provide these calculations. Please follow
these guidelines:
If the project is a newer development (newer than 1998), check the recent
improvement plans and observe if the new irrigation service is reflected on
the improvement sheets. If so, at the water meter station, the demand in
gpm may be listed there. Irrigation services are listed with a circled "I",
and potable water is typically a circled "W". The irrigation service should
look like:
I _J ,,-... STA 1+00 Install 2" service and
1.5: meter (estimated 100 gpm)
If the improvement plans do not list the irrigation meter and the
service/meter will be installed via another instrument such as the building
plans or grading plans (w/ a right of way permit of course), then the
applicant must provide irrigation calculations for estimated worst-case
irrigation demand (largest zone with the farthest reach). Typically, Larry
Black has already reviewed this if landscape plans have been prepared,
but the applicant must provide the calculations to you for your use. Once
you have received a good example of irrigation calculations, keep a set for
your reference. In general the calculations will include:
Hydraulic grade line
Elevation at point of connection (POC)
Pressure at POC in pounds per square inch (PSI)
Worse case zone (largest, farthest away from valve
Total Sprinkler heads listed (with gpm use per head)
Include a 10% residual pressure at point of connection
3. In general, all major sloped areas of a subdivision/project are to be
irrigated via separate irrigation meters (unless the project is only SF0 with
no HOA). As long as the project is located within the City recycled water
H:WORDDOCSIcMKISfl8u1idkig Paniedc cklst Fomi (Genef440c 6 Rev. 7114100
1
BUILDING PLANCHECK CHECKLIST
- 1ST 2ND 3RD
service boundary, the City intends on switching these irrigation
services/meters to a new recycled water line in the future.
0 12c. Irrigation Use (where recycled water is available)
1. Recycled water meters are sized the same as the irrigation meter above:
2. If a project fronts a street with recycled water, then they should be
connecting to this line to irrigate slopes within the development. For
subdivisions, .this should have been identified, and implemented on the
improvement plans. Installing recycled water meters is a benefit for the
applicant since they are exempt from paying the San Diego County Water
Capacity fees. However, if they front a street which the recycled water is
there, but is not live (sometimes they are charged with potable water until
recycled water is available), then the applicant must pay the San Diego
Water Capacity Charge. If within three years, the recycled water line is
charged with recycled water by CMWD, then the applicant can apply for a
refund to the San Diego County Water Authority (SDCWA) fora refund.
However, let the applicant know that we cannot guarantee the refund, and
they must deal with the SDCWA for this.
0 0 M. 13, Additional Comments:
HWORDDOC$OLS18IIgPIanthedI Cldst Fann (Geneilc).doc 7 Rev. 7I14ICO
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
N Plan Check No. CB 03 /6'6 Address Z7c(2 (JiJICOP-Al, Q
Planner Gieq-.sher t4L4'CL_— Phone (760) 602-4&2'e C16 t•3
APN: 2i O— 1
Type of Project & Use: 0-6-R #. b 6 Net Project Density: A,11A DU/AC
Zoning: General Plan: 24 44\ Facilities Management Zone: (
CFD (in/out) #_Date of participation: ,V/4 . Remaining net dev acres:______
Circle One (For non-residential development: Type of land used created by this
permit:______________________________________________________________
Legend: Z Item Complete Item Incomplete - Needs your action
Environmental Review Required: YES -
TYPE
DATE OF COMPLETION:
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval:
Discretionary Action Required: YES - NO 2<,TYPE
APPROVAL/RESO. NO. DATE
PROJECT NO.
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval:______________________________________________________
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES NQ)
CA Coastal Commission Authority? YES_ NO
If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite
103, San Diego CA 92108-4402; (619) 767-2370
Determine status (Coastal Permit Required or Exempt):
Coastal Permit Determination Form already completed? YES NO
If NO, complete Coastal Permit Determination Form now.
Coastal Permit Determination Log #:
AM
Follow-Up Actions:
Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans).
Complete Coastal Permit Determination Log as needed.
Inclusionary Housing Fee required: YES - NO,''
(Effective date of lnclusionary Housing Ordinance - May 21, 1993.)
Data Entry Completed? YES NO -
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing
Y/N, Enter Fee, UPDATE!) .
H:\ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9101
Site Plan:
1. Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines,
easements, existing and proposed structures, streets, existing street improvements, right-
of-way width, dimensional setbacks and, existing topographical lines (including all side and
rear yard slopes). XE] 0 2. Provide legal description of property and assessor's parcel number.
Policy 44 - Neighborhood Architectural Design Guidelines
0 Applicability: YES NO________
0 ________
EJ
Project complies YES NO
0
"'o
Zoning: •
Setbacks: • F
Front: Required Shown 2-0
Side: Required 7.' Shown 7 ?t 7. .Interior
Street Side: Required /0 1 Shown (0 I'.,... - Rear: Required 11 Shown 2.c7
Top of slope: • Required I(.IM Shown
Accessory structure setbacks:
Front: Required Shown
Interior Side: Required A] / Shown
Street Side:• Required I" /' Shown
Rear: Required //.1_. Shown
Structure separation: Required Shown
Lot Coverage: • Required ___ Shown f
LD 0 Height: Required .3O Shown
0 5. Parking: Spaces Required 2- Shown
(breakdown by uses for commercial and industrial projects required)
Residential Guest Spaces Required Shown
0 0 0 Additional Comments____________________________________________________________
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER l4Pbtf2__ DATE-- %-/ 7-22
H:ADMiN\COUNTER\BidgPInchkRevChkiSt Rev 9101
C J
09-12-2003
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Plan Check Revision Permit No: PCR03I80
Building Inspection Request Line (760) 602-2725
Job Address: 2740 UNICORNIO ST CBAD -
Permit Type: PCR Status: ISSUED
Parcel No: 2153505700 Lot #: 0 Applied: 08/26/2003
Valuation: $0.00 Construction Type: NEW Entered By: SB
Reference #: CB031096 Plan Approved: 09/12/2003
Issued: 09/12/2003
Project Title: HACKER RES REV BATH ADDITION Inspect Area:
REDUCING BDRM
Applicant: Owner:
ALEX FAULKNER LA COSTA INDUSTRIES CORP
SUITE#1 17 6965 EL CAMINO REAL #1054117 09/12/03 0002 01 02
2120 JIMMY DURANTE BLVD 92014 CARLSBAD CA 92009 COP 60.00
858-481-1819
Plan Check Revision Fee $60.00
Additional Fees $0.00
Total Fees: $60.00 Total Payments To Date: $0.00 Balance Due: $60.00
FINAL APPROVAL
Date: Clearance:
NOTICE: Please take NOTICE that approval of your project includes the imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
FOR OFFICE USE ONLY
PLAN CHECK NO. FC7 Q
3j
EST. VAL.
Plan Ck. Deposit_____________________
Val
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008
'Legal Description - Lot No. Subdivision Name/Number Unit No. Phase No. Total # of units
Assessor's Parcel # . Existing Use Proposed Use
Description of Work. 50. FT. #of Stories # of Bedrooms # of
4ø/,W6 ITI &DQgfl ed Aci ,mA / / . •.......V.....,• '. • V.S..-.. 2 CONTACT PERSON (if diiieren from applicant) - T4
Name Address City State/Zip Telephone # Fax #
0 6D -
Name Address City State/Zip Telephone #
--PROPERT:WNERi
Name Address City . State/Zip Telephone II
I1QMPANY N .. * :: ....
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
[Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged
exemption Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($5001)
Name Address City State/Zip Telephone #
State License I! License Class City Business License #
Designer Name Address City State/Zip Telephone
State License /1
COMPENSATL
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation, as required by Section 3700 of'the Labor Code, for the performance of the work for which this permit is
- issued. My worker's compensation insurance carrier and policy number are:
insurance Compiny
. Policy No._______________________________ Expiration Date___________________
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($1001 OR LESS)
CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for, which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California.
WARNING: Failure to secure workeré' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for In Section 3706 of the Labor code, interest and attorney's fees.
SIGNATURE DATE
7OWNER_BUILDER_DECtARATION
I heieby affirm that I am exempt from the Contractor's License Law for the following reason:
I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
said-within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
I, as owner of the property, am exclusively contracting with licensed contractors to construct the 'project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law). . .
I am exempt under Section Business and Professions Code for this reason:
I personally plan to provide the major labor and materials for construction of the proposed property improvement. DYES ONO
I (have / have not) signed an application for a building permit forthe proposed work.
I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number):
I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number / contractors license number):
I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number type
of work):
PROPERTY OWNER SIGNATURE - - - DATE
T7. TTITJ T J
Is the applicant or future building occupant required.to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance-Account Act? 0 YES 0 NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or'air quality management district? 0 YES 0 NO
Is the facility to be constructed within 1,000 feet of the Outer boundary of a school site? 0 YES 0 NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY, NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
I ',r'? - , -e ,:eej,CONSTRU,CTlOf&LENDING.AGENCY - _____ -- ••••--
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code).
- LENDER'S NAME LENDER'S ADDRESS
IEZA
-.
1_APPLIANT CER1IFICATION JJ. ..
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives' of the Citt of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE. INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'O", deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the building c I under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is not co
~ap
thi 8 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned
at any time after the w6rk is co ence or i of 180 days (Section 106.4.4 Uniform Building Code).
DATE APPLICANT'S SIGNATURE
-
. - WHITE: File YELLO : Applicant PINK: Finance -
List 1- Permit-Type
From the following list, determine the permit-type that best describes the work you propose to do. Please put the code of that
permit-type in the blank at the top of the page on the front of this application. Residential permits (only) also require the
identification of the structure-type to be associated with the permit. Choose a structure-type from "List 2 - Structure-Type? and put
its code in the appropriate blank on the front of this application.
Residential Permits
Code Description
APT Apartments - new construction.
CONDO Condominiums - new construction.
CVNNR Conversion. Convert all or a portion of a non-residential building to residential use, creating one or more new
residential units.
CVNRN Conversion. Convert one or more residences in a building to non-residential usage.
CVNRR Conversion. Increase or reduce the number of dwelling units in a residential structure through interior modifications
(i.e.: a four bedroom house converted to a duplex, with 2 bedrooms each).
DEMO Demolition permit. (Also specify type of structure from List 2).
DUP I Duplex - new construction.
MOHO Mobile home, renovation, repair, or addition of accessory structure not yielding a new living unit.
MOHON Mobile home, pre-fabricated house, or trailer installed (plumbed, wired) in a mobile home park (see distinction from
single-family residence, below).
RAD Residential addition/alteration, creating no new dwelling unit(s).
RREISSUE Residential permit re-issue.
RREPAIR Residential building repair. Damage, fire, etc.
RREPLACE Residential building replacement (no additional units).
SFA Single-family, attached - new construction. A one-family house attached to one or more other houses, with one or
more common walls extending from foundation to roof at, or forming, a lot line. Has own plumbing and heating
system (e.g.: townhouse, row house, half-plex)
SFD Single-family, detached - new construction: A one-family house with open area on all four sides. May have an
attached or detached garage, or a business. May be a detached "granny flat". May be a mobile home or trailer on an
individual lot, but not in a mobile home park.
Non-Residential/Accessory Permits
Code Description
COM Commercial structure, new construction.
CREISSUE Commercial permit re-issue.
CREPAIR Commercial building - repair. Damage, fire, etc.
CREPLACE Commercial building - replacement.
Cli Commercial tenant improvement.
DEMO Demolition permit.
ELEC Electrical permit, for electrical work only.
HOTEL Hotel or motel (including Managed Living Unit hotel) - new construction.
HOTELR Hotel renovation.
INDUST Industrial structure, new construction.
lii Industrial tenant improvement.
MECH Mechanical permit, for mechanical work only.
MISC Miscellaneous. Use only if proposed work doesn't fit another activity type.
PATIO Patio and/or deck.
PLUM Plumbing permit, for plumbing work only.
POOL Gunite pools and spas.
RETAIN Retaining wall permit.
SIGN Sign construction/installation permit.
SOLAR Solar energy system installation permit (specify structure type to be served).
SPA Factory-made or Gurute.
List 2 - Structure-Type (Use with Residential Permit Only)
From the following list, determine the type of residential structure that best describes the structure on which you will be working.
Please put the code of that structure-type in the appropriate blank at the top of the page on the front of this application.
Code Description
SFA Single-family, attached. A one-family house attached to one or more other houses, with one or more common walls
extending from foundation to roof at, or forming, a lot line. Has own plumbing and heating system (e.g.: townhouse,
row house, half-plex).
SFD Single-family detached: A one-family house with open area on all four sides. May have an attached or detached
garage, or a business. May be a detached "granny flat'. May be a mobile home or trailer on an individual lot, but not
in a mobile home park.
MF2-4 Multi-family, 2 to 4 wilts. A residential structure on a single lot, containing two, three, or four dwelling units. Units
may share master heating, plumbing, or electrical service (e.g.: duplex, triplex, quad-plex).
MFS+ Multi-family, 5 or more units. Same as MF2-4, except the building has a t least five attached units on the same lot.
MOHO Mobile home, pre-fabricated house, or trailer installed (plumbed, wired) in a mobile home park (see distinction from
single-family residence, above).
• EsGil Corporation
- •. In cPartners flip witfi çovernment jot cBuiCiing Safety—
DATE: 09/05/03 ..• - U AP ICANT
JURIS
JURISDICTION: Carlsbad U PLAN REVIEWER
U FILE.
PLAN CHECK NO.: PCR03-180 ( Rev 03-1096) SET: I
PROJECT ADDRESS: 2740 Unicornio
PROJECT NAME: Deleted Bath Addition and Reduced Bedroom Extension for Hacker
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
LI The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
LI The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
LI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
LI The applicant's copy of the check list has been sent to:
Alex Faulkner
2120 Jimmy Durnate #117 Del Mar, Ca. 92014
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
LI Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Alex Faulkner Telephone #: (858) 481-1819
Date contacted: (by: ) Fax #:
Mail Telephone Fax In Person
REMARKS: Sending back previous approved City Sets.
By: Ray Fuller Enclosures:
Esgil Corporation
0 GA 0 MB 0 EJ 0 PC 08/28/03 tmsmtl.dot
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576
Carlsbad PCR03-180 ( Rev 03-1096)
09105/03
VALUATION AND PLAN CHEKFEE
JURISDICTION: Carlsbad PLAN CHECK NO.: PCR03480 ( Rev 03-1096)
PREPARED BY: Ray Fuller DATE: 09/05/03
BUILDING ADDRESS: 2740 Unicorñio
BUILDING OCCUPANCY: R3 TYPE OF CONSTRUCTION: VN
BUILDING 1
PORTION
AREA
(Sq. Ft.)
Valuation
Multiplier
Reg.
Mod.
VALUE ($)
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code 1GB IBy Ordinance
Bldg. Permit Fee by Ordinance vj
Plan Check Fee by Ordinance
I $60.00
Type of Review: 0 Complete Review Structural Only
0 Other
0 Repetitive Fee Repeats Hourly I 0.51 Hour *
Esgil Plan Review Fee I $48.00
* Based on hourly rate
Comments:
Sheet 1 of I
macvalue.doc
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER çá f'c& 03 11 Ro DATE______________
ADDRESS•
RESIDENTIAL
.:RESIDENTJALADDrrION:MINOR...
(<$10,000.00) •.
TENANT IMPROVEMENT
PLAZA AM1No REAE.....
CARLSEAD COMPANY STORES
VILLAGE FAIRE
COMPLETE OFFICE BUILDING!
OTHER _
tñ
PLANNER____________________ DATE .
ENGINEE,-
\'
7
OocslMlsformsIPlannlng Engineering Approvals
DATE
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check No. CB PCJ' O2O Address 21L10 Ui crn i
Planner Rebeca Vazquez Phone (760) 602-4625
APN. ?JS— 35-0-S-1-00
Sm Type of Project & UsA'' Cf4rc DU/AC
ca a Zoning: P-1 General Plan: 1CLM Facilities Management Zone:
CFD (in/out) #_Date of participation: Remaining net dev acres:______
Al t (For non-residential development: Type of land used created by this Circle One permit: )
Legend: 0 Item Complete El Item Incomplete - Needs your action
Environmental Review Required: YES NO )1. TYPE
DATE OF COMPLETION:
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval:
Discretionary Action Required: YES NO TYPE
H.
APPROVAL/RESO. NO. DATE
PROJECT NO.
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval:
El Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES____ NO)(
CA Coastal Commission Authority? YES____ NO____
If California Coastal Commission Authority: Contact them at — 7575 Metropolitan Drive, Suite 103,
San Diego CA 92108-4402; (619) 767-2370
Determine status (Coastal Permit Required or Exempt):
Coastal Permit Determination Form already completed? YES____ NO____
If NO, complete Coastal Permit Determination Form now.
Coastal Permit Determination Log
Follow-Up Actions:
Stamp Building Plans as "Exempt' or "Coastal Permit Required" (at minimum Floor Plans).
Complete Coastal Permit Determination Log as needed.
D El Inclusionary Housing Fee required: YES NO
(Effective date of Inclusionary Housing Ordinance - May 21, 1993.,)
Data Entry Completed? YES ____ NO
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N,
Enter Fee, UPDATE!)
H:ADMlN\cOUNTER\BIdgPlnchkRevChkIst . Rev 9/01
Site Plan:
0 0 Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines,
( easements, existing and proposed structures, streets, existing street improvements, right-of-way
width, dimensional setbacks and existing topographical lines (including all side and rear yard
slopes).
rEfO 0 2. Provide legal description of property and. assessor's parcel number.
Policy 44- Neighborhood Architectural Design Guidelines
0 0 Applicability: YES NO________
O 0 0 Project complies YES NO________
ffl--]0
Zoning:
1. Setbacks: .
.
.
Front: Required 2L3 Shown 2._O
Interior Side: Required z.1 T1' Shown-1 74)
Street Side: Required tO' Shown
Rear: Required 't I'4 Shown • 20
Top of slope: Required r Shown
O 0 0 29essory structure setbacks:
Froht Required Shown
lnterio?SJe: Required Shown
Street Sid Required Shown
Rear: Required Shown
Structure separati6h... Required Shown
J C"D 0 Lot Coverage: Required 't07' i Shown
0 0 Height: Required Shown
O U Parking: Spaces Required Shown ' 2'
(breakdown by uses for commercial and industrial projects required)
Residential Guest Spaces Required Shown
EJ E1 0 Additional Comments_______________________________________________________
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE__________
H:\ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01