Loading...
HomeMy WebLinkAbout2810 CARIBOU CT; 110; FPC2020-0186; PermitPERMIT REPORT Lcity of Carlsbad Print Date: 12/04/2020 Job Address: 2810 CARIBOU CT, # 110, CARLSBAD, CA 92010 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2091200300 Track U: Valuation: $251,758.63 Lot U: Occupancy Group: Project U: Uof Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Plan Check #: Permit No: FPC2020-0186 Status: Closed - Finaled Applied: 10/22/2020 Issued: 11/02/2020 Finaled Close Out: 12/04/2020 Inspector: Final Inspection: Project Title: Description: ZENSE -MONITORING SYSTEM T.I. (MONITOR & CONTROL OF AIR HANDLERS, PROGRAM NEW DEVICES INTO THE EXISTING SPRINKLER ALARM PANEL) Applicant: FPContractor: CVA SECURITY CHULA VISTA ALARM INC JAMES RODRIGUEZ P0 BOX 211870 6175 PROGRESSIVE DR, U STE 400 CHULA VISTA, CA 91921-1870 SAN DIEGO, CA 92154-6648 (619) 585-9111 (619) 585-9111 FEE AMOUNT FIRE Sprinkler Monitoring $383.00 Total Fees: $383.00 Total Payments To Date: $383.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov PROJECT: Suite 110 Tenant Improvement Zense Office & Lab Carlsbad Oaks Innovation Park Lot 4 2810 Caribou Court Carlsbad, CA 92108 SYSTEM: EXPANSION OF THE EXISTING SPRINKLER MONITORING SYSTEM FOR THE ZENSE SUITE 110 TENANT IMPROVEMENT SUBMITTED BY: CVA Security 6175 Progressive Avenue Suite 400 San Diego, CA 92154 PHONE: (619) 585-9111 DATE SUBMITTED: October 20, 2020 Potter IPA-60 Fire Alarm System Equipment NEW EQUIPMENT LIST Model # Description Mfg. CSFM# PAD 100-TRTI Input/Output Module Potter 7300-0328:0514 2-Relays & 2-Input Modules RTS 151 KEY Remote Test Switch System Sensor 7300-1653:0212 (for Duct Detector) EXISTING EQUIPMENT FOR REFERENCE IPA-60 Fire Alarm Control Panel Potter 7165-0328:0500 UD-2000 DACT Module Potter 7300-0328:0515 LE4010CF Universal Communicator TYCO/DSC 7300-1273:0506 Central Station UL Certificate of Compliance (E)POTTER The Symbol of Protection jOTRTI Two Relay TWO Input Module Features Single module with dual contact monitoring inputs Two (2) Class B or one (I) Class A monitoring inputs Two (2) Form C relay contacts SLC Class A, Class X & Class B a Mounts in a standard 4" or double gang box Wiring terminals accessible when mounted in box , pollER All wiring terminals accept 22 to 12 AWG cu11c Product includes a 5 year warranty UUKL Listed for Smoke Control rsJnTr. This cgldrpccnhlp n,nrliiip dnpc not c.inn nrt 2-wire cn,nire detectors. -'-" !I () APPROVED Description The PADIOO-TRTI uses one (1) SLC loop address when monitoring two (2) Class B circuits or one (1) Class A circuit. The PADIOO-TRTI also provides two (2) Form C relay contacts. The module mounts on either a 4" square or double gang box. The module is capable of monitoring two (2) separate Class B circuits making it ideal for monitoring sprinkler waterfiow and valve tamper switches when they are located in the same proximity. The PAD 100-TRTI includes one red LED to indicate the module's status. In normal condition, the LED flashes when the device is being polled by the control panel. When an input is activated, the LED will flash at a fast rate. Application The PAD 100-TRTl is compatible with Potter's IPA and AFC/ARC series addressable fire alarm control panels. The PAD 100-TRTI is an interface module used to monitor dry contact devices such as sprinkler waterfiow, valve tamper switches, or conventional pull stations. The module is capable of monitoring two separate Class B or one Class A circuits. The PAD 100-TRTI also provides two (2) form C relay contacts. Setting the Address Each addressable SLC device must be assigned an address. The address is set using the DIP switch located on the PAD 100-TRTI. The he PAD 100- TRTI is assigned a single device address, each input and relay is identified as a sub-point of that single module address. For example, if the address number is assigned as "8", the RLYI relay will be "8.1", the RLY2 relay will be "8.2, the BI input will be "8.3" and the B2 input will be "8.4". Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to the panel or device: Power to the device is removed. Field wiring is correctly installed. Field wiring has no open or short circuits Technical Specifications Operating Voltage 24.OV Max SLC Standby Current 2401iA Max SLC Alarm Current 2401iA Relay Contacts 2A @30VDC, 0.5A @I25VAC Max Wiring Resistance of IDC loon Max Wiring Capacitance of IDC 11iF EOL Resistor 5.1K 92 Operating Temperature Range 32 to 120°F (0 to 49°C) Operating Humidity Range 0 to 93% (non-condensing) Max no. of Module Per Loop 127 units Dimensions 4.17" (106mm)L x 4.17" (106mm)W x 1.14" (29mm)D Mounting Options Standard 4" Square or Double Gang Box Shipping Weight 0.6 lbs Potter Electric Signal Company, LLC • St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830080- REV D 12/18 PAGE 1 OF 2 (E)POTTER PADIOO-TRTI The Symbol of Protection Two Relay Two Input Module Installation Using Compatible Electrical Box Fig I Wiring Diagrams PAD] OO-TRTI With One Class A Circuit MOVE SWITCH Fig 2 K IQ TOUP POSITION FOR CLASS A WIRING FROM FACP OR PREVIOUS MODULE TO NEXT MODULE -, •—" TWO(2) FORM C ml - CONTACTS L, l,c O NOTE: END-OF-LINE RESISTOR IS NOT REQUIRED PAD] OO-TRTI With Two Class Circuits -TOOOWN POSITION Fig 3 FOR CLASS B WIRING FROM FACP OR PREVIOUS MODULE I I _________ TO THE NEXT MODULE ' 1I• m-' ______ Ør TWO (2) FORM C END-OF-LINE RESISTOR 5.1KOHM (W Part 93005013 LaIItT:IIII L CONTACTS END-OF-LINE RESISTOR 5.1KOIIM (W Part 03505013 It is possible that the internal relay in the PAD100-TRTI may be shipped in the non-normal / activated state. To ensure that the internal relay is set to the normal state, connect the module to the SLC loop and reset the control panel before terminating the wiring to the modules output. Ordering Information Model Description Stock No. Two Relay Two Input Input Module 3992701 Potter Electric Signal Company, LLC • St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830080-REVD • 12/18 PAGE 2OF2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0328:0514 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Potter Electric Signal Col 609 Park 370 Place, Hazelwood, MO 63042 United States Contact: Bill Witherspoon (314) 595-6731 Fax (314) 595-6999 Email: billwpottersignal.com DESIGN: Model PAD100-DIM Dual Input Module Model PAD100-LED Addressable LED Module Model PAD100-OR0I One Relay-One Input Module Model PAD100-RM Relay Module Model PAD100-SIM Single Input Module Module) Model PAD100-ZM Zone Module Model PAD100-IM Isolator Module Model PAD100-NAC Notification Appliance Circuit Module Model PAD100-SM Speaker Module Model PADIOO-MIM Micro Input Module Model PAD1 --- LEDK Key Switch Module Model PAD100-DRTS Duct Remote Test Switch Model SLCE 127 Point SLC Expander Model MC-1000 Multi Connect Model PAD100-DUCTR Model AE-2 Enclosure Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as fire alarm control unit accessories for use with listee's separately listed fire alarm control panels. Refer to listee's Installation Instruction Manual for details. 09-11-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division SYSTEM SENSOR Duct Smoke Detector Accessories Expand the versatility of the InnovairFIef line of duct smoke detectors with System Sensor notification and test accessories. Available Accessories APA151 Piezo Annunciator MHR Mini-Horn, Red MHW Mini-Horn, White RA100Z/RA100ZA Remote Annunciator FITS 1 51 Remote Test Station 5X ______E 3 ______ RTS2 Multi-Signaling Accessory AOS Add-On Strobe RTS2-AOS Multi-Signaling Accessory Agency Listings ®<> ØI( 7300-16530212 LISTED APPROVED 7300-1653:0211 S2522 3034401 7135-1653:0196 9080301 Duct smoke detector accessories add functionality to the duct smoke detection system by allowing quick, convenient inspections at eye level and effective audible and visible notification options. All System Sensor duct smoke detectors and accessories are UL listed. The APAI5I piezo annunciator, which replaces the APA451 with a new, improved look, provides an audible alarm signal, a red LED to indicate alarm status, and a green LED to indicate power status. It is intended for use with System Sensor 4-wire conventional duct smoke detector applications without a system control panel, to comply with NFPA 90A. The MHR and MHW SpectrAlertO Advance mini-horns feature temporal or continuous tones at high and low volume settings. Their small footprint allows mounting to single-gang back boxes for applications where a small device is desired. The RAIOOZ and RAIOOZA remote annunciators are designed for both conventional and intelligent applications. Their red LED provides visual indication of an alarm condition. The RTSI5I and emote test stations are automatic fire detector accessories designed to test duct smoke detectors from a convenient location. For 4-wire detectors, the RTS151KEY test station features a multi-colored LED that alternates between steady green and red. For 2-wire detectors, the LED illuminates red for alarm. The RTS2 and RTS2-AOS multi-signaling accessories are designed to work with InnovairFIex 4-wire conventional duct smoke detectors. These accessories include a key switch that can be used to select one of two connected sensors to be tested, reset, or both by a push button switch. They also enable sensitivity measurements using the SENS-RDR sensitivity reader (sold separately). The AOS (Add-On Strobe) is an optional accessory included with the RTS2- AOS model. Specifications, Duct Smoke Detector Accessories Voltage Regulated 24 VDC Power Requirements Alarm LED: 2.8 to 32 VDC, 12 mA max. Operating Voltage 16 to 33 VDC Total Current: 105 mA max. Maximum Alarm Current 30 mA Test Switch 10 VA @ 32 VDC Temperature Range 0°C to 49°C (32°F to 120°F) Reset Switch 10 VA © 32 VDC Relative Humidity 10 to 93% non-condensing Alarm Response Time 40 seconds max. Wire Gauge 12 to 18 AWG Temperature Range -10°C to 60°C (14°F to 140°F) Dimensions 4.6H < 2.9W .45" D Relative Humidity 95% non-condensing MHR/MHW SpectrAlertO Advance Mini-Horns Wire Gauge 14 to 18 AWG Voltage Regulated 12 DC or FWR (Full Wave Dimensions 4.8"H x 2.90"W x 1.4"D Rectified) or Regulated 24 VDC or FWR RTS1 51 KEY Remote Test Station with Key Sounder Current Draw 22 mA RMS max. at 8 to 17.5 Volts DC Power Requirements Power LED (Green): 14 to 35 VDC, 29 mA RMS max. at 16 to 33 Volts DC 12 mA max. Temperature Range 0°C to 49°C (32°F to 120°F) Alarm LED (Red): 2.8 to 32 VDC, Humidity Range 10 to 93% non-condensing 12 mA max. Total Current: 105 mA max. Nominal Sounder 3 kHz Frequency Alarm Response Time 40 seconds max. Wire Gauge 12 to 18 AWG Temperature Range -10°C to 60°C (14°F to 140°F) Dimensions 4.6-H < 2.9W x 0.45"D Relative Humidity 95% non-condensing ____________________ Remote _Annunciator ____________________________ Wire Gauge 14 to 18 AWG Voltage Range Conventional System: 3.1 to 32 VDC Dimensions 4.6"H x 2.75"W x 1.8"D Intelligent System: 18 to 32 VDC RTS2 and RTS2-AOS Multi -signaling Accessory Maximum Alarm Current 10 mA Voltage 20 to 29 VDC Dimensions 4.6 "H x 2.8w x 1.3D Power Requirements Standby: 3.0 mA max. Trouble: 16.0 mA max. Alarm without strobe: 30 mA max. Alarm with strobe: 55 mA max. Sounder 85 dBA at ten feet Temperature Range -10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14 to 22 AWG Dimensions 4.8"W x 5.3"H x 1.6'D For the very latest product specifications and listing information, please visit the System Sensor Web site at www.systemsensor.com. RTS151 UL S4011 RTS151 KEY UL S2522 APA151 UL S4011 RTS2-AOS UL S2522 I RA100Z UL S2522 MHW UL S4011 MHR UL S4011 AOS SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 ©2Ol3SyseSesor. for current product irriormation, inciuding the iatest version 01 this data sheet. SENSOR Phone: 800-SENSOR2 • Fax 630-377-6495 Prduci sped' cic's sudleci to change adhout notice. Visit 5y51e"Se'socoro www.systernsensor.com VOSOOgOO • 8/13 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:0212 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models RTS151 , 5 Kjgand RA100Z Duct Smoke Detector accessories. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Refer to the installation manuals. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 04-03-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division EXISTING EQUIPMENT FOR REFERENCE (E)POTTER The Symbol of Protection Features 60 addresses available on this analog addressable system Additional system capacity achieved via multi-point SLC modules 99 software zones NFPA 72 Compliant Smoke Sensitivity Test Built-In System Operates as Class A or Class B for SLC, P-Link and NACs 5 Amp Power Supply, Expandable to 310 amps 2 NACS, Regulated, Rated at 3 Amps each, expandable to 188 2 Input/Output (I/O) Circuits for system flexibility rated at 1 Amp each, ideal for manual release and abort Strobe Synchronization and System Wide Sync for Potter/AMSECO®, Gentex®, Cooper Wheelock® and System Sensor® strobes Dedicated Alarm, Supervisory and Trouble Relays 4,000 Event History Buffer Cabinet will house up to 18 AH batteries Optional two line DACT with UD-2000 that can report General, Zone or Point Information Built in IP Communicator Ethernet Port for Programming and Network Connectivity E-Mail System Status, Reports and Event Information Product includes 5 year warranty. UUKL Listed for Smoke Control Description The TPA-60 is an analog/addressable releasing fire alarm system with a total system capacity of 60 addresses. Additional capacity on the system is achieved using multi-point SLC modules. The control panel utilizes the exclusive Potter protocol that includes a complete line of sensors and modules. Each SLC may be comprised of any combination of smoke sensor, heat detectors or modules and allows for a total of 50 ohms of impedance and may use any wire compliant with the National Electrical Code (NEC). The TPA-60 has a 5 Amp power supply with two Notification Appliance Circuits (NACs) and two Input/Output (1/0) circuits. The NACs are rated at 3 Amps each and the I/Os are rated at lAmp each. Each output is regulated and power limited. In addition, each output is uniquely programmable and may be configured for steady signal, strobe synchronization, constant power, door holder power, or releasing. The strobe synchronization includes Potter/AMSECO, Gentex, System Sensor and Cooper/Wheelock and with the exclusive Quadrasync each output may have a unique brand and all strobes will flash together. The 1/Os are designed for inputs such as manual release stations and abort switches that will not require polling and react nearly instantaneously. The IPA-60 is listed for releasing of fire suppression systems. The software allows cross zones, counting zones, and timers for suppression. The system is capable of multiple release outputs across multiple hazards. In addition, the PSN-1000 may be used to extend releasing capability. The NACs may be expanded using the PSN-1000 series intelligent power supplies. Each PSN-1000 adds another 10 Amps of power, 2 additional input circuits and the IPA-60 will support up to 31 power supplies. The system will synchronize the strobes system wide. In addition, the PSN- 1000E has space to allow the installation of up to six expansion cards. The cards mount on a stacker bracket that allows access to all SLC circuit connections. Fire Alarm Cdon 511I NE ' <S> APPROVED LISTED Technical Specifications Dimensions 16"W x 17H x 3 7/8"D AC Mains 3.0 Amps @ 120 VAC 50/60 HZ 2.0 Amps @ 240 VAC 50/60 HZ Enclosure 16 gauge cold rolled steel with removable locked door with Lexan viewing window Standby Current-130 niA Alarm Current-200 mA 5 Amps power for NACs, I/O, and P-Link Battery 3 Amps per NAC, regulated 1 Amp per I/O circuit, regulated Battery Charger range 8-55 Ah Battery Charger voltage 27.3 VDC P-Link maximum current of 1 Amp Temperature and 32° to 1200 (0°C to 49°C) with a maximum Humidity Range humidity of 93% non-condensing. NFPA 12, 12A, 13, 15, 16, 17, 17A, 70, 72, 750, and 2001 ANSI/UL 864 - Local (L), Remote Sta- tion (RS), Central Station (CS), Propriety (PPU), Auxiliary (AUX).Type of Service: Standards Automatic (A) Manual (M) Water flow (WF) Sprinkler Supervisory (SS) Type of Signaling: Digital Alarm Communicator (DAC), March Time (March), Non Coded (NC), Reverse Polarity (Rev Poll, Other Technologies (OT) IBC 2000, 2003, 2006, 2009, 2012 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830101-REVG • 9/19 PAGE 10F4 (2,)POTTER The Symbol of Protection IPA-60 Fire Alarm Control Panel SLC Loop Accessories The control panel may be connected with up to 60 addressable devices or modules in any combination. The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device Description PADI 00-PD Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot. PAD I 00-PHD Combination Analog Photo Electric Smoke/Heat Detector - a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 135° Fahrenheit heat detector. PADIOO-HD Analog Fixed Temperature Heat Detector that is selectable from 135° F to 185°F. PAD 100-DUCTR Addressable Duct Smoke Detector with Form C Relay. PAD100-DUCT Addressable Duct Smoke Detector. PAD100-613 6" round base that is mounted to an electrical box and wired for connection of one of the above sensors. PAD 100-413 4" round base that may be mounted to an electrical box and wired for connection to the above sensors. PADI 00-lB Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop. PAD100-RB Addressable Relay Base that contains one relay controlled by the SLC. Relay is rated at rated at 2 amps at 30 VDC or 0.5A at I25VAC. PA.D100-SB Addressable Sounder Base that contains an addressable sounder module that may be configured for local, group and all call. PADl00-CD Addressable CO gas detector. PAD100-DD Addressable photo electric smoke detector for use in DUCT/DUCTR enclosure. PAD100-LFSB Addressable Low Frequency Sounder Base that contains an addressable sounder module that may be configured for local, group and all call. The LFSB complies with the Low Frequency Signal Requirements (520 Hz) PAD 100-SPKB Speaker base is a wall or ceiling mount speaker capable of 25 or 70.7 VRMS and is field selectable from 1/8W to 4W. Modules Device Description PADlOO-MIM Micro Input Module provides a small foot print contact module for mounting inside an enclosure. PADIOO-PSSA Single Action Addressable Pull Station. PADl00-PSDA Dual Action Addressable Pull Station. PAD 100-SIM Single Input Module is a standard contact module with an LED that mounts into a 4" square electrical box. PADI 00-DIM Dual Input Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. PAD100-TRTI Two Relay Two Input module provides two form C relays that are individually controlled by the control panel. Each relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. Also provides two contact inputs. PAD I 00-NAC Notification Appliance Circuit module is an addressable remote appliance circuit controlled by the panel. PAD100-ZM Zone Module is used to connect conventional 2-wire smoke detectors to the system. PAD 100-IM Module interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. PAD100-RIvI Relay Module that provides one form C relay controlled by the control panel. Relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. PAD 100-LED Module provides a single addressable LED that is controlled by the control panel. PAD 100-SM Speaker Module provides switching for two audio channels. PAD I 00-LEDK Addressable LED and key switch that mounts in a single gang box. PAD I 00-DRTS DUCTR Remote Test Switch that mounts in a single gang box and optionally supervised. PAD 100-OROl One Relay One Input Module provides one form C relay and one input. The relay is rated at 2 amps at 30VDC or 0.5 amps at 125 VAC. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830101-REVG • 9/19 PAGE 2OF4 (E)POTTER The Symbol of Protection SLC Features The Potter protocol is a digital protocol with a proven design for reliability and noise immunity. The system does not require special cable or conductors for connection of the Signaling Line Circuit as long as the cable is compliant with NFPA 70 and NFPA 72. The system allows for Class A or Class B installations as well as "T-Taps", with a max wiring distance of 10,000 Ft. Sensor Features The sensors through the fire alarm control panel provide a real time status as to the condition of the system. The smoke detector sensitivity, heat detector temperature level and drift compensation are all programmable options. The system also allows for a day/night mode where the panel automatically adjusts the sensitivity depending on the time of day. To assist in the reduction of false alarms, the smoke detectors also have a maintenance warning that sends a trouble signal when a detector is dirty to the point that it can no longer maintain the programmed sensitivity. User Interface The fire alarm control panel has a 2 x 16 LCD display to provide information to the system status. The keypad has navigation keys to allow manipulation of the Menu on board the panel. The panel is shipped standard with the following LEDs: AC Power - Green Alarm - Red Earth Fault - Amber Supervisory - Amber Silenced - Amber Trouble - Amber Pre-Release - Amber Release - Red The common buttons include a Silence, Reset, Acknowledge, and Drill. All of the buttons are accessible once the locked door is opened. P-Link The IPA-60 has a proprietary communication protocol that communicates through a RS-485 connection to field devices. Up to 64 devices may be connected to a single P-Link connection. The P-Link includes the communication terminals and regulated 24 VDC connection for the field devices. The field devices may be any of the following: RA-6075R —2 x 16 LCD annunciator with a key pad in a locked metal enclosure. IPA-60 Fire Alarm Control Panel RA-6500R(F) —4 x 40 LCD annunciator with a key pad in a locked metal enclosure. Flush mount version available. LED-16(F) - 16 LED annunciator with common indicators in a locked metal enclosure. Flush mount version available. PSN-1000(E) - 10 amp, remote intelligent power supply with 6 NACs, 2 Inputs and a P-Link repeater. This panel is listed in conjunction with the IPA-60 as releasing circuits. CA-6075 - Class A convertor that converts the SLC, NACs and P-Link connection UD-2000 - UL listed, Dual line telephone alarm communicator DRV-50 - LED driver expander, used to connect up to 50 LEDs in a graphic display FCB-1000 - Fire communication bridge, provides remote mounting of the Ethernet connection FIB-1000 - Fiber interface module, used to extend P-Link to multi- mode fiber (2 required) RLY-5 - Relay module, provides 5 form C relay contacts rated at 3.0 amps 24VDC/125AC SPG-1000 - Serial parallel gateway, allows for the connection to a serial or parallel printer The FIB-1000, FCB-1000 and the SPG-1000 may be installed in the stacker bracket or ordered with the optional rack mount enclosure. MC-1000 Multi-Connect allows up to sixty-three IPA series panels to share a single reporting technology. IDC-6 - Initiating device circuit provides 6 programmable inputs AE-2 - Two card expansion cabinet AE-8 - Eight card expansion cabinet AE-14 - Fourteen card expansion cabinet Ethernet/I.P. Connection The IPA-60 is shipped standard with an Ethernet connection. This connection is the programming port and may be connected to a building Wide Area Network (WAN) or Local Area Network (LAN). Once connected to the Internet, the panel may be selectively programmed to e-mail alarm conditions, trouble conditions, supervisory conditions, test, Event History and detector status. An e-mail may be sent to the panel and the panel will e-mail the event history, detector status, configuration file or server status to an authorized E-mail account. In addition, reminders may be set to send an e-mail for service, testing or other conditions. In addition, the Ethernet connection is UL listed as an IP communicator. The IP communicator is listed to report to the UL listed Sur-Gard III IP receiver. The IP communicator replaces the traditional less reliable alarm communicator transmitter that utilized telephone lines. The IP communicator is an active method of connection and communication to the monitoring station. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com 8830101-REVG • 9/19 PAGE 3OF4 (E)POTTER The Symbol of Protection IPA-60 Fire Alarm Control Panel Dimensions 0 ot TOP • . DEPTH = 3.75 oJ DOOR= 16.07" BACKBOX = 15.77" DEPTH = 3.84" LEFT SIDE BOTTOM :1 RIGHT SIDE Ordering Information Model Description Stock No. IPA-60 Fire Alarm Releasing Control Panel 3992714 Replacement Board IPA-60 3992738 DWG #593-1 Compatible Releasing Devices Note: For releasing applications please order the Potter EOLD (3005012) for circuits connected to a releasing solenoid or actuator. Brand Description Skinner 73218BN4UNLVN0C112CZ 732 I2BN4TNLVN0C322C2 Victaulic 753-E Series Mini Max MX 123 & MX200 wl 8876677 & 889323 Viking 11591, 11601, 11602, 13843,& 13844 TLX PA0036 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830101-REVG • 9/19 PAGE 4OF4 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0328:0500 Page 1 of 1 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Potter Electric Signal Col 609 Park 370 Place, Hazelwood, MO 63042 United States Contact: Bill Witherspoon (314) 595-6731 Fax (314) 595-6999 Email: billwpottersignal.com DESIGN: Models IPA-100, and IPA-4000 fire alarm control units. Automatic, Manual, waterfiow and sprinkler supervisory type device and local, auxiliary, releasing, remote station (PPU), proprietary (PPU) and central station (PPU) services. Refer to listee's Installation Instruction Manual for details. System components: PAD100-DIM Dual Input Module PAD100-LED Addressable LED Module PAD 100-OROI One Relay-One Input Module PAD 100-RM Relay Module PAD 100-SIM Single Input Module PAD 100 TRTI Two Relay-Two Input Module PAD 100-ZM Zone Module PAD 100-IM lolator Module PAD 100- NAC Notification Appliance Circuit Module PAD 100-SM Speaker Module PAD 100-MIM Micro Input Module PAD 100-LEDK LED Key Switch Module PAD 100-DRTS Duct Remote Test Switch PAD 100-SLCE127 Point SLC Expander MC-1000 Multi-Connect PAD 100-DUCTR AE-2 Enclosure *SLCE..127 Loop Expander RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. 01-14-2019 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division (E)POTTER The Symbol of Protection DigitalAlarm Communicator Features Allows for communication to Monitoring Station Communicates using SIA-DCS or Ademco Contact ID Protocols For use with IPA, AFC, and ARC series Addressable Panels and PFC-4064 Conventional Panel Status LEDs indicate operation of DACT card Installs with ease behind main panel LCD display via User Interface bracket Device address is set internally to address 1 Includes two (2) RJ45 phone cords <a> 0 @ LISTED Description The UD-2000 Digital Alarm Communicator Transmitter (DACT) provides for up to two (2) phone lines for communication to a monitoring station. The UD-2000 communicates using the SIA- DCS or Ademco Contact ID protocols. When enabled, the DACT automatically monitors each phone line or voltage and has the ability to seize the line and connect with a remote receiver. Once the communication is complete, the DACT will hang up. The DACT is provided with terminal blocks for each phone line and two RJ45 cords. In order for the DACT to work properly, it must be installed on a plain old telephone service (POTS) line or equivalent deemed by the authority having jurisdiction. The DACT must be installed before any other equipment to ensure it can seize the phone line. Phone lines are high voltage and should be run in a separate conduit from other circuits. The wire conductors connecting the DACT to the phone system should be 26 AWG or larger. Technical Specifications Operating Voltage 22.0-24.0V Standby Current 16mA Alarm Current 23mA Max UD-2000s per panel 1 Dimensions 4"W * 6"H * 1-518"D Operating Tempuratures 0°C - 49°C (32°F- 120°F) Operating Humidity Range 10% - 93% @ 30°C (86°F) (non-condensing) Mounting Options In FACP Behind keypad Shipping Weight 0.47 lbs Potter Electric Signal Company, LLC St. Louis, MO Tech Support: 866-956-1211 / Customer Service: 866-572-3005 www.pottersignal.com 8830146- REV B • 6/19 PAGE 10F3 (E.)POTTER The Symbol of Protection UD-2000 DigitalAlarm Communicator RJ31X Phone Jack to UD-2000 Plain Old Telephone (POTS) lines Tip (Brown) Ring (Grey) Out to Premises Phones Out to Premises Phones I I - Grey ,, I 2-Tan \/' ))I I 3-Black O VS[_-J 4-Red S - Green 6 - ''ello' J1illUlltlii\UI I 7-Blue 8-Brown Ring (Red) Tip (Green) Line In From Telco Tip (Green) Ring (Red) Line In From Telco e 2 ie 1 Ring Ring UD-2000 Communicator Telco Tip = Red Telco Ring = Green Phone Tip = Brown Phone Ring = Grey Installation The UD-2000 DACT is connected to the control panel using the provided four-wire cable connection (P/N 5210514) between P4 and UD-2000 Pt. The connection is power limited and supervised. Power system down. Slide the UD-2000 into the card guides located under the User Interface bracket. Secure the UD-2000 to the User Interface bracket using the provided 46-320/8" screw Install the provided four-wire conductor jumper between UD-2000 P1 and P4. Potter Electric Signal Company, LLC St. Louis, MO • Tech Support: 866-956-1211 / Customer Service: 866-572-3005 www.pottersignal.com 8830146- REV B • 6/19 PAGE 2 OF 3 onnector main board TOE]) F~~io 4~ 1 a1 000 a L..JL.I000 D 0 [iies in guiden under 0 . e DWC*593-32A U U P Connector on small platform control panel Li (E)POTTER UD-2000 The Symbol of Protection Digital Alarm Communicator UD-2000 DACT Installation on UD-2000 DACT Installation on Small Platform Panel Large Platform Panel Fig I Fig 2 Ordering Information Model Description Stock No. Digital Alarm Communicator 3992769 Potter Electric Signal Company, LLC St. Louis, MO Tech Support: 866-956-1211 / Customer Service: 866-572-3005 www.pottersignal.com 8830146-REVB • 6/19 PAGE 3OF3 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0328:0515 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Potter Electric Signal Col 609 Park 370 Place, Hazelwood, MO 63042 United States Contact: Bill Witherspoon (314) 595-6731 Fax (314) 595-6999 Email: billwpottersignal.com DESIGN: Models UD-1000 and igital Alarm Communicator Transmitters (DAd). Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as a digital alarm communicatior for use with listee's separately listed fire alarm control panels. Refer to listee's Installation Instruction Manual for details. *Rev 01-09-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division From Tyco Security Products Ensure your installations are future-ready, with LTE Features That Make a Difference: Uses LTE network for high- speed, reliable and low-cost communications to an IP receiver Automatically switches to 3G (HSPNHSPA+) if LTE service is not available Compatible with control panels that communicate using Contact ID or SIA (300 baud) formats Full event reporting 4 on-board inputs with NC, NO or SEOL supervision 4 on-board outputs (open collector) Activation and initialization via website or mobile interface provided by C24 Communications View communicator status directly from your mobile phone to support on-site or remote troubleshooting Compatible with Sur-Gard® System l-IP/Il/lll/IV/5 monitoring station receivers Includes UL listed power supply, transformer and 7 Ah rechargeable battery UL 864 listed CSFM listed Due to rapidly-evolving cellular technologies, 2G/3G network sunsets are already on the horizon - with some having already been completed. Now's the time to adopt and adapt. Switch to LTE today, to offer customers long-lasting investment protection, and reduce your future truck rolls. The LE401 OCF connects the alarm control panel to the Cellular network and reports alarm signals directly to a monitoring station receiver (Sur-Gard System l-IP/11/111/IV/5). The LE401 OCF uses the Cellular network to ensure low-cost, high-speed and reliable alarm communications and is compatible with control panels that communicate using the Contact ID or SIA (300 baud) format. The LE401 OCF is compliant with the latest requirements for Communications Methods as per UL864 and NFPA72 2010, 2013, and 2016 editions. It can be used in Fire Monitoring applications as a single communications technology, in which case any failure of the communications path shall be annunciated at the supervising station within 5 minutes (NFPA72 2010) or 1 hour (NFPA72 2013/2016) of the failure, or it can be used as part of a multiple communications technologies (for example in conjunction with a DACT). When used as a back-up provision shall be made to monitor the integrity of each communication path and failure of any communications path shall be annunciated at the supervising station and at the protected premises within not more than 24 hours of the failure. How it Works The LE401 OCF can be used as either a Sole Communicator or as a Backup Communicator. When being used as a Sole Communicator the LE401 OCF will replace the phone line connection on the panel and as soon as it detects that an alarm needs to be transmitted it will send the alarm across the Cellular network immediately. When being used as a backup the communicator assesses the connection to the PSTN phone line, and only in the event of a phone line failure will it send all alarm traffic across the Cellular network to the monitoring station. DBO From Tyco Security Products In instances where the control panel does not support Contact ID or SIA (300 baud), the LE401 OCF has inputs pre- set to transmit fire alarm, fire supervisory or system trouble. Alarm signals are transmitted directly without the need of a clearinghouse to the IF linecard of the monitoring station receiver (Sur-Gard® System l-IP/11/111/IV/5). Activating & Initializing the Unit Activating and initializing the LE401 OCF can be done using the website interface provided by C24 Communications. No special tools are required. Mobile Site for Easy Installation and Comprehensive Maintenance C24 Communications mobile site (m.connect24.com) makes the installation a simple process and offers intuitive trouble-shooting features, cutting down on time and cost allocated to maintenance. UL Listing The LE401 OCF is UL listed under File S4019, Listing guide UOXX, as a sole or backup communicator for Commercial Fire monitoring installations. When used as a sole communicator under NFPA72 2010 guidelines the LE401 OCF will send its heartbeat once every 97 seconds ensuring that three heartbeats will be received at the supervising station within the 300 second window. When used as a sole communicator under NFPA72 2013/2016 guidelines the LE401 OCF will send its heartbeat once every 5 minutes to monitor connectivity with the supervising station within the 1 hour window. When used as a backup communicator the LE401 OCF will monitor the other communication method (DACT) and send a daily test transmission to the supervising station. CSFM Listing The LE401 OCF has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. Ordering Information: - -- L'1 LL .JUJJU.-cdiS Rate Plan Cost-effective rate plans have been negotiated and are available through authorized master resellers. Contact your monitoring station or visit www.connect24.com to find a master reseller. When used as a sole communicator, the LE401 OCF requires use of the 4MB (NFPA72 2010) or 5001<13 (NFPA72 2013/2016) rate plans to support the supervision requirements. Specifications Dimensions ................................................1 1-1/2 x 10 x 3 (290 mm x 254 mm x 75 mm) Input Voltage.............................................................120 VAC Current Draw ..............................................200 mA (standby) 400 mA (transmitting) Operating Environment ................32° to 120° F (0° to 49° C) Weight...........................................................12.8 lbs (5.8 kg) Optional Acessories Model Description LTE-1 5ANT 15 ft extension antenna LTE-25ANT 25 ft extension antenna LTE-50ANT 50 ft extension antenna 8 C CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. t0IP6) Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Tyco Safety Products Canada Ltd.3301 Langstaff Rd., Concord, Ontario L4K 41-2 Canada Contact: Dan Nita (905) 760-3000 Fax (905) 760-3020 Email: dnita@tycoint.com DESIGN: interface. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as a interface for use with a separately listed fire alarm control unit. Refer to listee's Installation Instruction Manual for details. NOTE: Burglary and other non-fire functions were not examined. 01-11-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAViD CASTILLO,, M. E, F.P.E. Fire Engineering Division UL CERTIFICATE OF COMPLIANCE for Central Station (J Applicant ID No: 892912-001 L Service Center No: I Expires: 31-MAR-2021 CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. Listed Service From: HUNTINGTON BEACH, CA (HUNTINGTON Alarm Service Company: (892912-001) Service Center: (892912-001) GENERAL MONITORING SERVICES INC GENERAL MONITORING SERVICES INC 17951 LYONS CIR 17951 LYONS CIR HUNTINGTON BEACH CA 92647-7167 HUNTINGTON BEACH CA 92647-7167 The Alarm Service Company is Listed in the following Certificate Service Categories: File - Vol No. CCN Listing Category S78941 uuFx,/ [Signal and Fire Alarm Equipmeitand Services] (Protective Signaling Services) Central Station I \ / \\ ***THIS CERTIFICATE EXPIRES ON / 31-MAR-2021' "LOOK FOR THEUL ALARM SYSTEM CERTIFICATE" /