HomeMy WebLinkAbout1350 POINSETTIA LN; ; FA140106; Permit5/27/2021 FA140105 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FA140105 1350 POINSETTIA Job Address: Status: APPROVED LN Permit Type: FALARM Applied 8/21/2014 Parcel No: 2150704900 Approved: 8/25/2014 Lot #: 0 Reference No. Issued: 8/25/2014 PC #: Inspector: Project Title: NO COAST CALVARY CHAPEL Install new addressable fire alarm system in new chapel building. Will provide sprinkler monitoring, notification to occupants where required and duct detection on air moving systems exceeding 2000 cfm. The fire alarm will be monitored by a U.L. listed monitoring service. Applicant: EMCOM ELECTRONIC SYSTEMS, INC. SUITE H 256 WITH ERSPOON WY EL CAJON, CA 619-667-1200 Owner: CALVARY CHAPEL NO COAST 1330 POINSETTIA LN CARLSBAD CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 370 0 370 0 1/1 C-ti t 1 Parsley Consulting Plan Review Comments for North Coast Calvary Chapel page 2 of 2 ' ab 1) The requirements contained in NFPA 72, section 7.7.2 must be verified, including: A documentation cabinet installed at an approved location [7.7.2.1] Record documentation is required to be stored in that cabinet [7.7.2.2] Indication on the control unit as to the cabinet location should be provided if the cabinet is not at the control unit. [7.7.2.3] Cabinet should be prominently labeled "SYSTEM RECORD DOCUMENTS" [7.7.2.4] Contents of the cabinet are to be accessible only by authorized personnel. [7.7.2.5] Cabinet should include copies of record of completion, record of inspection and testing, and risk analysis. [7.8.2] We strongly recommend the following operational tests be performed once the system installation has been completed. A "power off' test, where the normal power supply is shut off, and the system is left to function on battery power alone for a period of 24 hours, at which time the system should still be functioning and operational. At the end of the end of the above test, prior to the primary power being restored, the system should be placed in an "alarm" condition for a period of not less than five minutes, during which time all notification appliances, including the off-station notification, are to function as designed. Once the two prior tests have been completed, the current level in the batteries should be checked, the primary power restored, and at the end of 48 hours the current level checked again to verify that the charging function of the panel is both operational, and able to recharge the batteries within the time period specified by NFPA-72. Once the test in item "c" has been completed, one of the leads to the battery should be disconnected, to determine that the system will provide notification of an "off-normal" power condition to the monitoring company. File: i :\Plan Rev iews\Rev2 14310.1 .Docx EMCOM ELECTRONIC SYSTEMS, INC. CA LIC. 820216 SEC. LIC ACO 3838 256 WITHERSPOON WAY, SUITE H' ELCAJON, CA 92020 • PH. (619) 667-1200 • FAX (619) 667-1222 00) 0)0 Fire Alarm System I c E c7)4(nZ 0 oN Equipment Submittal LI.. For tZ North Coast Calvary Chapel I <a 1350 Poinsettia Lane Uj co Carlsbad,Ca.92011 10.5 hcc phis hivc hlxii 101 1 1'trcI1i Compliance wiih he culic Iii appliciihle eodcs iiid in he iundic1I01i flk OWIi.I or COilti actor 1155 uttitie ceRn in stlppoil -)f an applicillinil lor a biiildiItg en perlilil ith i 1es undrStit11l that this ie ill in ¼ I\ tell en the owner or contractOr 01 lien viol e,si rial cit'lllcel 01 fflCt I lot dc rc ponsihil1tv lull cnnIPlitIi with said codes itil ntattdtrds tncltidin the hinkliitg code r lot ally ,c5poitsihi11Y for o deticicilcicn errorS. 0fl11 titus or itC lCCilLC it these review: iltits whether ni tint toted in this l)aie:g / Is1u RevtcR Lt1 REC()MMF' Aihll(O\','L kCOMMENI) APlttt)VA AS NUlL) I I INTELLIGENT FIRE ALARM CONTROL PANELS FX-350-60-DR Description The FX-350-6O-DR Intelligent Fire Alarm Control Panel is a single lccp acdressable panel that supports up to 60 addressable ports. The FX-350-6CDR s equipped with a two line by 20 character oackA LCD display, numerical keypad and an integrated !JDACT/Digital Communicat:- Th.e LCD dspay albws for 32 characters to be configured fo user defined messages. I, addition the FX-350 Series family also includes remote LED and LCD annunciators- The FX-350-60-DR is ideal for both new and retrofit applications. Designed for small to medium commercial, institutional and industrial occupancies, these panels are powerful enoh to meet today's nstailatior. demands. The FX-35C-E0-DR is configurable by the keypad for onsite progra-Tming or by a PC f- .:c.t,h onsite and remote programming. Easy' to instal an simple to operate and ccifigire, the FX-350-0-DR enables the installer to c.onfigue the system tc meet :heir specific requirements.. The FX-35&6O-DR is eaupped with a 5.5 Amp power supply, auxiliary resettable smoke power supply (300mA max.), an interface for a Remote Trouble Indicator (RTI- 1) and an RS485 interface for remote _CD and LED annunciators. The FX-350-3-DR comes complete a red door, black enclosure, durable CAT-30 lock and ke-y End space to mount up to 12 AH batteries. An optional trim ring is available for se'ri-fi'sh mounting. Single Addressable SLC Loop that supports 60 addressable points Points can be any combination of Addressable Sensors or Modules Supports Ionization Sensors, Photoelectric Sensors, Variable Heat Sensors and Multi—Sensor (Heat/Photo) Equipped with a 2 line by 20 character backlit LCD display, numerical keypad and an integrated UDACT/ Digital Communicator LCD display allows for 32 characters to be configured for user defined messages Digital Communicator can be configured for DACT or UDACT mode of operation Configurable via the front panel, PC Configurator, or remote dial up through the built-in modem Sensors can be configured asAlarm, Verified Alarm, Latching or Non-Latching Supervisory, Monitor and Trouble-Only Modules can be configured as Alarm, Latching Supervisory, Non-Latching Supervisory, Water Flow, Monitor, Trouble, Fire Drill Switch, Signal Silence Switch, Aux Disconnect Switch and Buzzer Silence Switch Base panel is equipped with Four Class "B" (Style "B") indicating circuits which may be configured as Class "A" (Style "Z') using a Class "A" signal converter module Indicating Circuits may be configured as Silenceable or Non-Silenceable for both signals and strobes Built-in sync protocols for the following strobe manufacturers: Mircom, Amseco, System Sensor, Gentex, Faraday and Wheelock Relay contacts for Common Alarm, Auxiliary/ Alarm (Disconnectable), Common Supervisory and Common Trouble Configurable Signal Silence Inhibit, Auto Signal Silence and One-Man Walk Test SubsequentAlarni, Supervisory, and Trouble operation RS-485 Interface for Remote LED and LCD Annunciators Positive Alarm Sequence Interface for a Remote Trouble Indicator (RTI-1) Two event history logs comprised of a 200 event alarm log for alarm related events and a 200 event general log for all other events 5.5 Amp Power Supply Optional modules for additional internal relay circuits and City Tie/Polarity Reversal Optional trim ring for semi-flush mounting cII MEA approved City of Chicago S7010 7165-1477:156 313-97-E Aporoved for Class Applications I I I I I I L I I I I I I I Fj I CATALOG NUMBER 5670 1401 IC BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes a any time withcut notice ir. prices, colours, materials, components, equipment, specifications and models and also to discontinue models. I I MS-71 OIDU Intelligent Addressable Dual Action Manual Station ALPHA INTELLIGENT ADDRESSABLE MANUAL STATIONS MS-700IDU SERIES MS-701lDu Intelligent Addressable Single Action Manual Station Description Mircom's MS-7001DLJ Series provide manual fire reporting. These high quality, die-cast metal Intelligent Fire Alarm Manual Stations are available in either single or dual action configurations with a permanently attached addressable module. The MS-7001DU Series stations are available as single or dual-action devices with key resets .and a permanently attached addressable module . The addressable manual station has DIP switches which allow for address setting. Pulling the handle initiates The operation of the adcressable module. All models are available with CAT-30 keys and mount on a standard single gang backbox, Mircom model BB-700 interior surface metal backbox, or BB-700WP weather proof backbox. Operation The MS-70110U Single Action Intelligent Manual Station is operated by puling down the handle marked "PULL HANDLE" on the front of the station. The MS-71OlDU Dual Action Intelligent Manual Station is operated by pushing the bar labelled PUSH BAR" and then pulling down the handle marked "PULL HANDLE". The MS-70001-1 Series Manual Stations are reset by opening the station with the key, placing tie handle in the normal upright position and re- locking the station. Features Single or Dual Action Key resettable Permanently Attached Intelligent Addressable Module High-gloss red enamel finish Plastic breakrod Meets ADA 5 lb. maximum manual-force Mounts on standard single gang box, Mircom's BB-700 surface metal backbox or BB-700WP weather proof backbox Specifications The manual station shall be Mircom's MS-700IDU Series. Operating instructions shall be in raised English lettering and the unit shall be constructed of high quality die-cast metal and finished in red enamel paint to provide quick identification. Pulling the handle shall initiate immediate operation of the intelligent addressable module. All manual fire alarm stations shall be installed as per the specific requirements outlined in the UL codes, as well as all other applicable national or local codes. Final acceptance is subject to the local authority having jurisdiction. 0 & @ 7150-1477:128 S7005 S7005 I I I I I I I I I I 1 I 1 I CATALOG NUMBER NOT TO BE USED FOR INSTALLATiON PURPOSES. 5679 Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. I I I ALPHA INTELLIGENT ADDRESSABLE DETECTORS MIX-3000 SERIES Features Low profile design For use with the FX-350 Series Fire Alarm Control Panels Fast response time MIX-3000 MIX-3100 Ionization Smoke Detector Photoelectric Smoke Detector Automatic addressing with the MIX-ADD card Variety of mounting bases I Ease of installation Elegant, unobtrusive design Digital communications I MIX-3200 Multi-Sensor Detector Description MIX-3300 Thermal Detector Mircom's Alpha Series Intelligent Addressable Detectors are designed to meet a wide range of applications. The detector's address is set in its base providing a convenient and trouble free maintenance procedure. The detectors mount into a selection of base styles to accommodate installation requirements. Intelligent Ionization Smoke Detector (MIX-3000) The Ionization smoke detector incorporates a unique dual chamber design to respond quickly and dependably to a broad range of fires. The ionization detector is equipped with a red LED which flashes when the detector is polled and turns on steady when the detector goes into alarm. (UL Listed) Intelligent Multi-Sensor Detector (MIX-3200) The Intelligent Multi-Sensor Detector is a photoelectric smoke detector with a supplementary thermal sensor. The Multi-Sensor detector combines photoelectric smoke and thermal sensor values to provide enhanced detection performance and reduction of false alarms. Information from each sensing element is processed and conditioned by an on-board advanced technology ASIC and digitally transmitted to the FACP as a single analog value comprised of the combined responses from both the photoelectric smoke and thermal detection elements. Intelligent Thermal Detector (MIX-3300) The Intelligent Thermal Detector utilizes state of the art electronic temperature sense to provide fast and accurate temperature monitoring. The thermal detector features an adjustable termperature range that is configured from the FX-350 Series fire alarm control panel. I I I 1 I Intelligent Photoelectric Smoke Detector (MIX-3100) The Intelligent photoelectric smoke sensor utilizes a unique optical sensing chamber that is designed to sense smoke produced by a wide range of combustion sources. The photoelectric detector is equipped with a clear LED which flashes when ' the detector is polled and turns on steady when the 7271477138 (MIX-3000) S6295 (MIX-3000.MLX-3100 & MIX-3200) S6965 (MIX-3100 & MV -3200) detector goes into alarm. 7272-1477:131 S6299 S7498 (MIX-300) 7272-1477:142 (MIX-3X0) (MIXZ) (MX-2W) 7270-1477:139 (MIX-3") CATALOG NUMBER 5676 NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. ALPHA INTELLIGENT ADDRESSABLE MODULES MIX-1 00 SERIES I . ----- --. I MIX-101P MIX-1 OOP MIX-100S MIX-bOX Features Designed to meet a wide range of applications For use with the FX-350 Series Fire Alarm Control Panels Fast response time Priority Interrupt feature on monitor modules Monitor modules can be wired as a Class A (Style D) or Class B (Style B) Each module can be addressed from 1 t 126 Eight position dip switch for address setting Red light indiáator Modules mount in standard 4" junction box I 1 I I Description Mircom's Alpha Series Intelligent Addressable Modules are designed to meet a wide range of applications. The monitor and control modules can be used to supervise and activate sounders, strobes, door closers, pull stations, waterflow switches, conventional smoke detectors and more. An eight position dip switch allows for the address setting of the device and the wiring class/style of the devices that are connected to the module. All modules mount in a standard 4" x 4" x 2 1/8" junction box. Intelligent Addressable Priority Monitor Module (MIX-loop) The Intelligent Addressable Priority Monitor Module (MIX-100P) provides an address for a group of UL/ ULC Listed normally open (NO.) initiating devices, such as heat detectors, beam smoke detectors, 4- wire smoke detectors, waterfiow switches, manual pull stations, etc. wired in a Class A (Style D) or Class B (Style B) initiating circuit. The MIX-100P is equipped with a priority interrupt to provide a fast response to emergency conditions. The MIX-100P has an activated red LED. Intelligent Addressable Priority Mini-Monitor Module (MIX-IOIP) The Intelligent Addressable Priority Mini Monitor Module provides an address for a group of UL/ULC Listed Normally Open (NO.) initiating devices, such as heat detectors, projected beam smoke detectors, 4-wire smoke detectors, waterfiow switches, manual pull stations, etc. wired in a Class A (Style D) or Class B (Style B) initiating circuit. The MIX-101P is equipped with a priority interrupt to provide a fast response to emergency conditions. The MIX-101P has an activated red LED. Intelligent Addressable Relay Module (MIX-IOOR) The Intelligent Addressable Relay Module connects to the same loop as the initiating devices and provides two isolated sets of Form-C contacts to control a variety of normally open or normally closed contact applications cuch as fan operation and door closures. The MIX-i OOR has an activated red LED which follows the state of the relay contacts. @ @ 0 S5434 S5434 7150-1477:156 I I I I I I U I I-. CATALOG NUMBER 5675 NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also 10 discontinue models. I *,7' SYSTEM 4 SENSOR' D4120 Duct Smoke Detector The lnnovairFlex'TM Series are the only duct smoke I L] Li Li detectors flexible enough to fit configurations from square to rectangular and everything in between. inn OVait' I Features 4-Wire Photoelectric, integrated low-flow technology Air velocity rating from 100 ftlmin to 4,000 ft/min (0.5 m/s to 20.32 m/sec) Versatile mounting Options: square or rectangular configuration Plug-in sensor offers superb false alarm immunity and the latest sensor technology Broad ranges for operating temperature (-4°F to 158°F) and humidity (0% to 95% non-condensing) Patented sampling tube installs from front or back of the detector with no tools required Increased wiring space with a newly added 3/4-inch conduit knockout One easy-access Test/Reset button and improved LED status Patented interconnect feature for multi-tan shutdown New high contrast terminal designations Built-in short circuit protection from operator wiring errors Field selectable settings for configuring the detector Two DPDT Form-C relay contacts 24 VAC/DC or 120 VAC Backward compatibility with existing Innovair products, including remote accessories Agency Listings @ <~> 0 LISTED APPROVED Soil 303374 7272-16530253 The InnovairFiex 04120 4-wire photoelectric duct smoke detector features a pivoting housing that fits both square and rectangular footprints and mounts to round or rectangular ductwork. I his unit senses smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute, temperatures of —4°F to 158°F, and a humidity range of 0 to 95 percent (non- condensing). A plug-in sensor head offers improved false alarm immunity and simple installation, testing, and maintenance. An improved cover design isolates the sensor head from the low-flow feature for simple maintenance. The InnovairFIex housing provides ample wiring space, a %-inch conduit knockout, and built-in short circuit protection to prevent damage to sensitive components during installation. High contrast terminal designations make wiring easy. With its 2:1 sensor-to-power capability, the power board of the 04120 may be used to monitor a second sensor, 04S, simultaneously (i.e., supply and return side). As many as 50 InnovairFIex detectors can be interconnected. When one unit senses smoke, all interconnected detectors will switch their relays; only the detector sensing smoke will go into alarm, thus pinpointing the fire source. An easy-access Test/Reset button makes it possible to test the unit with the cover on. Three DIP switches can be used to configure field selectable settings: cover tamper delay, number of sensors to be controlled, and shut down on trouble option. Each power board has two LEDs that can be used to indicate the status of connected sensors, and a quick reference imprinted on the cover explains the LED status indications (Standby, Maintenance, Trouble. and Alarm). The lnnovairFfex duct smoke detector can be customized to meet local codes and specifications without additional wiring. The new lnnovairFlex product line is compatible with all previous fnnovair models, including remote test accessories. WARNING: Duct smoke detectors are NOT a substitute for open area smoke detectors; NOT a substitute for early warning detection; NOT a replacement for a building's regular fire defection system. Refer to NFPA 72 and 90A for additional information. I I 1 I I I COOPER Notification I Ll Weatherproof Appliances - Series AH Audibles, AS Audible Strobes, MT Multitone Strobes, I RSS Strobes and ET70 Speaker Strobes and Weatherproof Mounting Accessories I i ji DI I Description: I Designed for life safety, performance and reliability, Cooper All models may be synchronized using the Wheelock DSM Sync Notification's Wheelock cost effective weatherpoof notification Modules, Wheelock Power Supplies or other manufacturers appliances include: panels incorporating the Wheelock Patented Sync Protocol. The I Weatherproof Appliances Series horn output of horn strobes can be independently controlled on 2-wire circuits using the Wheelock patented sync protocol. MTWP Strobes RSSWP horn strobe models are 4-wire appliances; the strobes can be Horn Strobes ASWP synchronized while the audible can be connected to a coded fire Horns AH24WP,AH12WP alarm system or can be set to produce any of eight selectable I Multitone Horn Strobes MTWP tones. Multitone Horns MT Speaker Strobes ET70WP Speakers ET-1010 Features: I All strobe models are UL dual listed - meeting both UL1638 Approvals include: UL Standards 1971, 1638, 464 and 1480 and UL1971 requirements. As dual listed appliances, these California State Fire Marshal (CSFM), New York City weatherproof strobes, horn strobes and speaker strobes are listed for outdoor applications under UL 1638 as well as under UL 1971, (MEA), Factory Mutual (FM), Chicago (BFP) and ULC . See I the Standard for Safety Signaling Devices for Hearing Impaired. agency approvals by model number on page two of this With an extended temperature range of —31°F to 150°F (-35°C document to 66°C), Wheelock weatherproof appliances meet or exceed UL Compliance with the following requirements: NFPA, UFC, outdoortest requirements for rain, humidity and corrosion resistance ANSI 117. 1, OSHA Part 29, 1910.165, ADA I while providing multiple strobe intensity options, including the highest strobe ratings available for area coverage per NFPA 72 • Weatherproof with extended temperature range of —40°F to strobe spacing tables (up to 185 candela for wall mounting and 177 150°F (-40°C to 660C)* candela for ceiling mounting). Dual Listed strobe models (UL 1638 and UL 1971) I To enable weatherproof mounting, Cooper Notification provides • Industry's highest strobe candela options the industry's widest choice of mounting options for surface or unique semi-flush installation. Models are available for surface Synchronize using the Wheelock Sync Modules or panels mounting to Wheelock weatherproof backboxes on walls or ceilings, with built-in Wheelock Patented Sync Protocol The optional WP-KIT allows the weatherproof backboxes (lOB, • Models with field selectable tone, dBA and candela settings I WPBB or WPSBB) to be mounted to a recessed electrical box for concealed conduit installation. For semi-flush installation, the • Wall or ceiling mounting options WPA* and WFPA* kits allow a customer to mount the weatherproof • Surface of semi-flush mounting appliances to a recessed electrical box without the need for an IN/OUT wiring termination accepting two #12-18AWG wires U external weatherproof backbox. See the Backboxes, Plates and at each terminal Gaskets Table on page three of this document for a summarization of these mounting options and the required accessories. The series RSSWP, ASWP, AH-24WP, MTWP-2475W, and MT-12/24 have UL / ULC approval down to -40°F. The ET-1010 and ET70WP have UL approval down to-40'F. The AH-12WP has UL approval down to -31 °F. i O' I APPROVED E5946 151-92-E 7125.0785:131 (ASWP) S5391 7125-0785:146 (ET70WP) S2652 7125-0765:156 (MTWP) I 7300-0785:154 Li CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM I .LISTING SERVICE LISTING No. 7165-1477:0156 Page 1 of 2 I CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: MIRCOM TECHNOLOGIES, LTD.25 Interchange Way, Vaughan, Ontario L4K 5W3 Canada I Contact: Mara Cherubin (888) 660-4655 Ext: 3110 Fax (888) 660-4113 Email: mcherubin@mircom.com DESIGN: Models FX-350-60-R, FX-350-60-DR, FX-350-126-R, FX-350-126-DR, FX-351-LW, FX-351-LD, I FX-351-LDW, FX-353-LDR, FX-353-LDW and FX-350-378-DR fire alarm control units. Local, auxiliary, remote station (PPU), central station (PPU), waterflow and sprinkler supervisory services. Refer to the listee's data sheet for detailed product description and operational considerations. System components: I MD-815; FX-350/FX-351 Mainboard - with Dialer *BBX1O24DS(R);Universal Backbox MD-837; FX-350/FX-351 Mainboard - No Dialer I MD-749; DSP Core Board MD-819; Power Supply Board PR-300; City Tie/Polarity Reversal I TR-061; 120/240 VAC Transformer. CH-613; FX-350 Backbox FX-350 Door FX-350 Deadfront I CH-643; FX-351 Deadfront FX-351 Door FX-351 Backbox I MD-825; *RAX 332 RAM-300-LCD; Remote LCD Annunciator MIX-1 OOP; Priority Monitor Module MIX-101P; Mini Priority Monitory Module I MIX-i OOS; Supervised Control Module MIX-i OOR; Addressable Dual Relay Output Module MIX-100X; Isolator Kit Li I Rev. 11-14-13 gt I This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not ./ an endorsement or recommendation of the item listed. This listing should not be used- to verify correct I operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 I Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division I I Listing No. 7165-1477:0156 I . Page 2of2 I. I RATING: 120 VAC, 60Hz 240 VAC, 50 Hz I INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances, and in a manner acceptable to the authority having jurisdiction MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with listee's separately listed electrically and I functionally compatible initiating and indicating devices as indicated in design. Refer to listee's Installation Instructions Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in I accordance with NFPA 72, 2002 Edition. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. This control panel meets the requirements of UL-864, 9th Edition. I I I I I *Rev. I This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not o an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 1 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division I I _ CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I . FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE I LISTING No. 7150-1477:0128 Page 1 of 1 I CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: MIRCOM TECHNOLOGIES, LTD.25 Interchange Way, Vaughan, Ontario L4K 5W3 Canada Contact: Mara Cherubin (888) 660-4655 Ext: 3110 Fax (888) 660-4113 I Email: mcherubin@mircom.com DESIGN: Models MS-701U, -703U, 704U, -710U, -713U, -714U, 701ADU, -710ADU, -702U, -702ADU, -70IUP, -710UP, -703U(C), -704U(C), .713U(C), -714U(C), -705U, -715U,-706U(C), -716U(C), I -707U(C), -717U(C) and -708 fire alarm boxes. These devices are manually actuated, single or dual action non-coded, fire alarm boxes. Units are to be mounted on standard outlet boxes or listee's Model BB-700 backbox for indoor use only and BB-700WP backbox for indoor and I outdoor use. Models MS- 701ID(U), -702lD(U) and -710lD(U) non-coded, indoor use only, fire alarm boxes. ' To be mounted on three-inch deep outlet boxes. Refer to listee's data sheet for additional detailed product description and operational considerations. ' RATING: 30VDC, 1A, 125 VAC, 1A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. I MARKING: Listees name, model number, rating, and UL label. APPROVAL: Listed as fire alarm manual pull stations for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. I * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. I I I *Updated 06-19-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division I I I I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM M4'W4_ I LISTING SERVICE LISTING No. 7272-1477:0131 Page 1 of 1 I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: MIRCOM TECHNOLOGIES, LTD.25 Interchange Way, Vaughan, Ontario L4K 5W3 Canada I Contact: Mara Cherubin (888) 660-4655 Ext: 3110 Fax (888) 660-4113 Email: mcherubin@mircom.com DESIGN: Model MIX-3100 photoelectric smoke detector. Refer to listee's data sheet for additional I RATING: detailed product description and operational considerations - Electrical: 17 to 28 VDC, 5 to 9V protocol INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances I and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a photoelectric smoke detector for use with listee's separately listed compatable I fire alarm control units and listed Models MIX-2000 Series detector bases (CSFM Listing No. 7300-1477:145). Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering I fires which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and I grease spread quickly. Sources of these fires may include paper burning in a waste container or a fire in the kitchen XLF: 7272-1394:0104 I I I I I 04-06-2005 I , This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee'sdata sheet, installation instructions and/or other Date Issued: July 01, 2014 ' Listing Expires June 30, 2015 I Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division I I _ CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINE ERING - BUILDING MATERIALS LISTING PROGRAM I LISTING SERVICE LISTING No. 7270-1477:0139 Page 1 of 1 I CATEGORY: 7270 -- HEAT DETECTOR LISTEE: MIRCOM TECHNOLOGIES, LTD.25 Interchange Way, Vaughan, Ontario L4K 5W3 Canada I Contact: Mara Cherubin (888) 660-4655 Ext 3110 Fax (888) 660-4113 Email: mcherubin@mircom.com DESIGN: Model MIX-3300 combination electronic/fixed temperature heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. I RATING: Fixed Temperature: 1310 -194 o F Electrical: 17 to 28 VDC, 5 to 9 V protocol ' INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. I APPROVAL: Listed as a heat detector for use with listee's separately listed compatible fire alarm control units and listed Models MIX-2000 Series detector bases (CSFM Listing No. 7300-1477:145). Refer to listee's Installation Instruction Manual for details. XLF: 7270-1394:0105 I I I I I I 04-06-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division I I I. I. I I I I I I I I I I I I I I I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING -SERVICE 3242-1653:0207 Page 1 of 1 3242 -- DUCT SMOKE DETECTOR, PHOTO. (W/ OR W/O BASE) System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Irish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com Models D4120, D4240, RD4120, P270-3000PL, TD41203, TD41204, LD4S, LD412OX, LD4120H, D45, D413120, CD4P120 LD4P120X, LD413120H, TD4C, PD4120, YD4120, YD4P120, and AD4P120 four-wire conventional photoelectric duct smoke detectors and subassemblies. Unit consists of a duct detector housing, powerboard with electrical components and relays, exhaust tubes, and listed 2D51 detector head (CSFM Listing No. 7272-1653:203). Model AD4S sensor component. Models *TD4C, LD412OX, LD4120H, LD4P120X and LD4P120H do not contain a 120 VAC transformer. Refer to listee's data sheet for additional detailed product description and operational considerations. 20-29 VDC, *24 VAC, 120 VAC (except Models *TD4C, LD412OX, LD4120H, LD4P120X and LD4P120H *do not have 120 VAC rating). In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, rating, air velocity and UL label. Listed as conventional photoelectric duct smoke detector for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. Date Issued: July 01, 2014 . Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division LISTING No. CATEGORY: LISTEE: DESIGN: RATING INSTALLATION: MARKING: APPROVAL: Rev. 03-27-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:0212 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNITACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhartsystemsensor.com DESIGN: Models RTS1 51, RTS1 51 KEY and RA100Z Duct Smoke Detector accessories. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Refer to the installation manuals. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable'to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 04-03-09 bh 0 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct Zo- operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ' OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM I LISTING SERVICE LISTING No. 7125-0785:0168 Page 1 of 1 I CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 I Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: Exceder Series: Models ST strobe, HS horn strobe and HN horn. Model ST is a synchronous I and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or W (white). Additionally, a 'C' may be added for ceiling models and/or a '- NR may be added for non-resettable models. For non -NR models and optional 'S for silver fascia may be added*. Refer to listee's data sheet for I additional detailed product description and operational considerations. RATING: Electrical: 12 VDCI24VDC/FWR Candela (wall): 15, 15/75, 30, 75, 95, 110, 135 & 185 ' Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances I and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. I APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. I I I I Rev. 9-24-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division I I [1 I _ CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM I LISTING SERVICE LISTING No. 7125-0785:0131 Page 1 of 2 I CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc. 7246 16th St.. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 I Email: thomas.conover@cooperindustries.com DESIGN: Models AS-1215, -2415, -1230,-2430, -121575, -241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens I orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters I indicating lens orientation, lettering and color. These units with suffix -W are for wall mount only. *Models AS-121575W and AS-241575W lens color may be white, red, blue, green, or amber. I Models AS-2415C, -2430C, -2475C and -24100C audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. I These units are intended for ceiling mount only. Model AH-12, -24, AH-12WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. I Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. *Lens color may be white, red, blue, green, or amber. I *ASWP2475C Models ASWP-2475W and audible/strobe with integral private mode fire/emergency visual signaling for ron-hearing impaired applications. Lens color may be white, red, blue, green, and amber. Both models are suitable for outdoor use when mounted I on the Model WPBB back box. Models AS-24MCWH, AS-24MCCH, *ASWP24MCWH and ASWP-24MCCH I audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. Units with suffix CH are for ceiling mount only. Units with suffix WH are for wall mount only. *Lens color may be white, red, blue, green, or amber. I Refer to the listee's data sheet for detailed product description and operational considerations. *Rev. 10-01-07 I This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 . Listing Expires June 30, 2015 I Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division I I Listing No. 7125-0785:0131 I Page 2of2 RATING: Electrical: 8-17.5/16-33 VDCNFWR Flash Rate: 60 flashes/minute Candela: 15:l5cd,1575:15/75cd,30:30cd,75:75cd,95:95cd,100:100cd, 110:ll0cd I MCW: Selectable 15cd, 30cd, 75cd,110cd MCC: Selectable 15cd, 30cd,75cd,95cd I MCWH: Selectable 135cd,185cd (65cd, 90cd at -40 C) MCCH: Selectable 115cd177cd (50cd, 75cd at -40 C) INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances I and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W, ASWP-24MCWH, AS-24MCW and AS-24MCWH are for wall mount only. Models ASWP-2475C, ASWP-24MCCH, AS-24MCCH, AND AS-24MCC are for ceiling mount only. Models with suffix -w or WH are for wall mount only. Models with suffix -C or -CH are for I ceiling mount only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when I used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-12WP, AH-24WP, *ASwp2475w ASWP-2475C, ASWP-24MCWH, and ASWP-24MCCH audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12/24, U DSM-12/24 or DSMX-12/24 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's Installation Instruction Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm I Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Models AH-12, AH-24, -12WP and -24WP audible devices are not suitable for the hearing impaired applications. I I I I I I Rev. 10-01-07 I This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct I operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division I PAt4Oto IN FI RappE of system acceptanc n complete and/or clear record. ::$JtECQPY 'CLtA CHURP SYSTEM RECORD OF COM This form is to e completed by the system installation contractor at the ti It shall be permitted to modify this form as needed to provide a mo Insert N/A in all unused lines. Attach additional sheets, d1ata, or calculations as necessary to Form Completion Date: 'T 2 I Supplemental P PROPERTY INFORMATION Name of property: 0114'A (àc&)c Cr! U (,Lq o, C"ci,. Address: C) seM p L(sAj Cy\ Description of property: ()vILA 'u I uit I - Name of property representative: Address: k 5O \pcyx 4 -t& ..—&.yLC. Phone: Fax: E INSTALLATION, SERVICE, TESTING, AND MONITORING INF( Installation contractor: --- Ct.3w- \ cA ( ô 'v L Address: 'LL &etcoovs..u3o\ Vce.Sk Phone: LbO Fax: (JACk') -ltfjL E Service organization 5 (p.i,-'— . C-.5 C\oO¼J e Address: Phone: Fax: E Testing organization: Xt. p¼e Address: Phone: Fax: E Effective date for test and inspection contract: IU 1 P. Monitoring organization: C €,v..A 'l(AN pysO Address: \'L.r2) k €..v\.. . OJU- Phone: LW()) tL\tBL Fax: ($3i Dko E Account number: 4 '\ Phone line 1: Means of transmissi n: 004\C'\ — ''v\OA..e, 5. Entity to which alanis are retransmitted: Gc..i\ '3Lt:AA DOCUMENTATIN On-site location of the required record documents and site-specific software: DESCRIPTION 9F SYSTEM OR SERVICE This is a: çl.New system 0 Modification to existing system Permit NFPA72 edition: 4.1 Control Unit Manufacturer: 4.2 Software and $'irmware Firmware revision number: TION CCL flCJ¼. cOtO (!J Phone line 2: O-\à \ 3O Phone: number: x — 4.3 Alarm Verification This sytem does not incorporate alarm verification. Number of devices sibject to alarm verification: Alarm verification set for seconds Copyright 0 201 National Fire I'rotection Association. This form may be copied for individual use other than for re ale. It may not be copied for commercial sale or distribution. (p. 1 of 3) 4. SYSTEM RECORD OF COMPLETION (c ntinued) SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of conto1 Overcurent protectitn: Branch Circuit discornecting 5.1.2 Secondary Power Type of secondary power: Location, if remote ftom Calculated capacity 4f In standly mode (hours): 5.2 Control Unit C3 This system do o Powr ex es tender i1ane1s CIRCUITS AND panel: tO \J PcC.' C Type: c.uk €C-r Amps: means location: 'i\ N %SN C ntrol panel amps: L) mber: the plant: 1 jC secondary power to drive the system: In alar ________________________________ mode (minutes): v. not have power extender panels are listed on supplementary sheet A PATHWAYS Pathway Type Dual Media Pathway Separate Pathway Class Survivability Level Signaling Lire Device _Power Initiating_De4ice Notification_ppliance Other (specify): REMOTE ANNUNCIATORS 91 Type 1 Lo ation INITIATING DEVICES Type - Quantity Addressable or Conventional Alarm o Supervisory Sensing Technology Manual Pull Stations o'( M Smoke Detectors Duct Smoke betectors (p $ .j , 4 p'( t) . 0 e\ Heat Detector's - ç)f Gas Detectors Waterfiow Sitches cJ am - - or' Copyright 0 201211,latlonal Fire Protection Tamper Swit0es ¶u Association. This form maybe copied for individual use other than for re J o). ye-- o-. le. It may not be copied for commercial sale or distribution. SYSTEM RECORD OF COMPLETION ntinued) NOTIFICATION PPLIANCES Type Quantity Description Audible ___- ) .iç p C, Visible ' CorfibinationlAudible and Visible SYSTEM CONTROL FUNCTIONS Type Quantity Hold-Open Eoor Releasig Devices HVAC_Shutdown Fire/Smoke Iampers Door _Unlock ing Elevator Recall Elevator _Shu lot _Trip INTERCONNEcTED SYSTEMS This system does not have interconnected systems. 0 Inter4onnected systems are listed on supplementary sheet CERTIFICATION AND APPROVALS 12.1 System Installtion Contractor This system as spec 1fied herein has been installed according to all NFPA stand ar Signed: - Printed name: -j Organiztion: c -pvC Title: 12.2 System Operational Test This sysem as specified herein has tested according to all NFPA standards cited Signed: Printed Printedname: Organiztion: c' Title: 12.3 Acceptance Test Date and time of acc eptance test: Installing, contractor representative: Testing contractor r~presentative: AHJ repiesentative: .- Copynght © 2012 National Fire P tection Association. This form may be copied for individual use other than for res s cited herein. (, 5 Date: Phone: (c') (jLg ierein. Date: ,~)~ 0A -LID( Phone: le. It may not be copied for commercial sale or distribution. (p. 3of3) ON