Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2700 RANCHO PANCHO; ; FA140164; Permit
Uity ot earisbaci Fire Alarm Permit Permit No: FA140164 2700 RANCHO Job Address: Status: ISSUED PANCHO Permit Type: FALARM Applied 11/20/2014 Parcel No: 2226000100 Approved: 11/21/2014 Lot #: 0 Reference No.: Issued: 11/21/2014 PC #: Inspector: Project Title: FAITH COMMUNITY CHURCH INSTALL A FIRE SPRINKLER ALARM MONITORING SYSTEM WITH VOICE EVACUATION, PULL STATIONS AT THE EXITS AND MONITOR THE DUCT SMOKE DETECTORS TO COMPLY WITH NFPA 72 AND SECTIONS 907 OF THE 2013 CBC AND CFC. 2013 CFC 907.7: ACCEPTANCE TESTS AND COMPLETION. UPON COMPLETION OF THE INSTALLATION, THE FIRE ALARM SYSTEM AND ALL FIRE ALARM COMPONENTS SHALL BE TESTED IN ACCORDANCE WITH NFPA 72. Applicant: Owner: PROTECTION ONE ALARM MONITORING, INC. FAITH COMMUNITY CHURCH BY-THE-SEA 9596 CHESAPEAK DR, STEA P 0 BOX 231460 SAN DIEGO, CA ENCINITAS CA 951-264-7678 Fees ($) Add'I Fees ($) Total ($) Balance ($) 382 0 382 0 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-0075:0211 Page 1 of 1 CATEGORY: 7120-- ANNUNCIATORS LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reynolds2Honeywell.com DESIGN: Model ANN-80 and *ANN..80w remote fire annunciators. Unit is a 80-character, supervised backlit LCD fire annunciator. Communication between the control panel and the annunciator is accomplished over a two-wire serial interface employing the ANN-BUS protocol. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listees name, product number, electrical rating and UL label. APPROVAL: Listed as an annunciators for use separately listed compatible fire alarm control units. Refer to Manufacturers Installation Manual for details. *Rev. 04-28-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0075:0184 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reynolds2Honeywell.com DESIGN: Models BG-12, BG-12S, BG-12NC, BG-12W, BG-I2LW, BG-12WP, BG-12LWP, BG-12L, BG-12LX, BG-12LA, BG-12PS, BG-12LSP, BG-12SP, BG-12LR, BG-12LRA, BG-12LAO, BG-12LAOB, BG-12-LO, BG-12LOB, BG-12LPS, BG-12LPSP, BG-125L, UT-PSi and UT-PS2 fire alarm pull boxes. The BG-12 series is a dual action pull station that has normally open switch contacts. Refer to listees data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number and UL label. APPROVAL: Listed as fire alarm boxes for use with separately listed compatible fire alarm control units. Models BG-12WP, BG-12W, BG-12LW and BG-12LWP are intended for outdoor use when installed with Model WP-10 back box. Models BG-LAOB and BG-12LOB are intended for outdoor use when installed with Model WBB or WP-1 0 back box. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 *updated 08-17-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. -0075:0226 J Page 1 of 1 CATEGORY: 6911 --VOICE COMMUNICATION SYSTEMS CONTROL UNITS LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reynolds2Honeywell.com DESIGN: Models ECC-50/100 and ECC-501100E. These are 50-wall audio emergency voice evacuation panels expandable to 100-watt for fire applications, mass notification applications, or both. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: ECC-MCB; Main Control Board ECC-DKVCM; Display Board ECC-50W-25V; Amplifier Module 25 VRMS ECC-50W-70V; Amplifier Module 70 VRMS ECC-MCB; Main Control Board ECC-DKVCM; Display Board ECC-50W-25V; Amplifier Module 25 VRMS ECC-50W-70V; Amplifier Module 70 VRMS ECC-CE6; Speaker Circuit Expander Module ECC-XRM-70V; Transformer Module 70.7 VRMS RATING: Primary Operating: 120 V, 60 Hz, 3.5 A or 240 V, 50 Hz, 2 A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as voice communication systems for use with separately listed compatible fire alarm control units to provide emergency voice evacuation signals. Refer to listee's Installation Instruction Manual for details. 05-02-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0075:0185 Page 1 of 1 CATEGORY: 7300— FIRE ALARM CONTROL UNITACCESSORIES/MISC. DEVICES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reynolds2HoneyweIl.com DESIGN: MMF-302, MCF-300 monitor modules; Models CRF-300 and CMF300 control modules; and MMF-302-6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. NOTE: *Rev. 05-06-05 JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0075:0210 Page 1 of 1 CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reynolds2HoneyweII.com DESIGN: jModel MS-9050UD addressable fire alarm control unit. Unit consists of one communication loop, two bell circuits, and three relay contact outputs for alarm, trouble and supervisory. Local, auxiliary, remote station, central station and proprietary (protected premise), automatic, manual, water flow and sprinkler supervisory service. Refer to listee's data sheet for detailed product description, operational considerations and required/optional accessories. When required, accessories shall be CSFM listed. RATING: 120 VAC, 60 Hz, 3.0 A Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as an addressable fire alarm control panel for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 07-07-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0075:0194 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reynolds2Honeywell.com DESIGN: Models SD350, SD350T, SD355, 5D355R*, 5D3551 and AD355 photoelectric type smoke detectors. Model SD350T and 5D355T has a 135°F supplement integral heat sensor which only assists in a fire situation. The purpose of this thermal circuitry is to increase the sensitivity of the detector. This thermal circuitry is NOT approved for use as a heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. All units are suitable for open areas and inside duct installations with air velocities between 04,000 FPM. Models SD355 and SD355R* are also approved for installations inside Fire-Lite Duct Housing D355PL (CSFM Listing No. 3242-0075:221) and System Sensor Duct Housing DNRW (CSFM Listing No. 3242-1653:210). NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev. 01-11-2010fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. .3:01 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SABCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8 - 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. "Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL r1JT FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7320-1653:0201------ Page 1 of 1 CATEGORY: 7320 LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Models SPRSPW,SPRV, and SPW SpectrAlert Speakers - Rectangular enclosure. Models SPCW, SPCR, SPCWV, and SPCRV SpectrAlert Speakers with round enclosure. Models SPSR, SPSRH, SPSW, SPSW-ALERT, SPSW-CLR-ALERT, *SPSWKCLRALERT SPSWH, SPSRV, and SPSWV SpectrAlert Speaker/Strobe with rectangular enclosure. Models SPSCR, SPSCRH, SPSCW, *SPSCWKCLRALERT SPSCWH, SPSCRV, SPSCRVH, SPSCWV, and SPSCVWH SpectrAlert Speaker/Strobe with round enclosure. Model SPSCW-CLR-ALERT Speaker/Strobe. Model SPSW-ALERT has amber lens and is intended for non-fire use. All models identified are intended for indoor use mounted on the wall or ceiling. Models with a "K" in the suffix are suitable for indoor or outdoor use with an operating temperature rating of -40°C to +66°C (-40°F to +151°F) and have a NEMA4X enclosure rating when used with models PWBB, PWBBW (wall) or the model PWBBCW (ceiling) plastic weatherproof back boxes or with Model MWBBW (Wall), MWBB (Wall) or MWBBCW (Ceiling) metal weatherproof back boxes. Models with a "- P' in the suffix have plain housings with no lettering on the enclosure. Models not containing °- P", in the suffix have English lettering reading "FIRE" on the housing. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Nominal Voltage: 25 Vrms or 70 Vrms Power Settings: %, %, 1, 2 Watts Frequency Range: 400 - 4000 Hz INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as speaker/strobes when used with separately listed compatible fire alarm control units. Suitable for wall or ceiling mount. These speaker/strobes do not generate a distinctive three-pulse temporal code pattern (for total evacuation) as required per NFPA 72, 2010 edition. If required, the appliances must be used with a fire alarm control unit that can generate the temporal pattern signal. *Corrected 02-06-12 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ov operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0186 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 762-5025 Fax (630) 377-7245 Email: trish.linhart@systemsensor.com DESIGN: Synchronous type strobe lights, Models SR, SRH, SW, SW-CLR-ALERT, SWH, SCR, SCRH, SCW, SCW-CLR-ALERT and SCWH followed by the suffix -P, -SP, -PG, or none. Intended for indoor use mounted on the wall or the ceiling. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-17.5 or 16-33 VDC/FWR Candela: 15, 15/75, 30, 75, 95, 110, 115, *135 *150 *177 *185cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights suitable for hearing impaired application when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Refer to listee's Installation Instruction Manual for details. Rev. 03-11-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division 1. df-52417:c • B-90 80-Character LCD Serial Annunciator General The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced condi- tions. The ANN-80 and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. ANN-80 is red; for white, order ANN-80-W. The ANN-80 displays English-language text of system point information including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes con- trol switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) Up to eight ANN-805 may be connected to the ANN-BUS of each FACP. No programming is required, which saves time dur- ing system commissioning. Features Listed to UL Standard 864, 9th Edition. Backlit 80-character LCD display (20 characters x 4 lines). Mimics all display information from the host panel. Control switches for System Acknowledge, Signal Silence, Drill, and Reset. Control switches can be independently enabled or disabled at the FACP. Keyswitch enables/disables control switches and mechani- cally locks annunciator enclosure Keyswitch can be enabled or disabled at the FACP. Enclosure supervised for tamper. System status LEDs for AC Power, Alarm, Trouble, Supervi- sory, and Alarm Silence. Local sounder can be enabled or disabled at the FACP. ANN-80 connects to the ANN-BUS terminal on the FACP and requires minimal panel programming. Displays device type identifiers, individual point alarm, trou- ble, supervisory, zone, and custom alpha labels. Time-and date display field. Surface mount directly to wall or to single, double, or 4" square electrical box. Semi-flush mount to single, double, or 4" square electrical box. Use ANN-SB80KlT for angled view mounting. Can be remotely located up to 6,000 feet (1,800 m) from the panel. Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs. May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC). Up to eight ANN-805 can be connected on the ANN-BUS. Controls and Indicators AC Power Alarm Trouble FlreLITeALarms by Honeywell Supervisory Alarm Silenced Specifications Operating voltage range: 18 VDC to 28 VDC. Current consumption @ 24 VDC nominal (filtered and non- resettable): 40 mA maximum. Ambient temperature: 32°F to 120°F (0°C to 490C). Relative humidity: 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). 5.375" (13.65 cm.) high x 6.875" (17.46 cm.) wide x 1.375" (3.49 cm.) deep. For use indoors in a dry location. All connections are power-limited and supervised. Agency Listings and Approvals The listings and approvals below apply to the ANN-80. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S2424 FM approved CSFM: 7120-0075:211 MEA: 442-06-E The ANN-BUS POWERING THE DEVICES ON THE ANN-BUS FROM AUXILIARY POWER SUPPLY The ANN-BUS can be powered by an auxiliary power supply when the maximum number of ANN-BUS devices exceeds the ANN-BUS power requirements. See the FACP manual for more information. FA140164 df-5241 7:c • 05/22/09 - Page 1 of 2 DF-52013:13 • E-100 BG.1 2LX Addressable Manual Pull Station General The Fire-Lite BG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for Fire-Lite's addressable fire alarm control panels (FACP5). Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-i 0 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4" (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable LEXAN® (or polycarbonate equivalent) with a textured finish. Specifications Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC loop current: 230 VA. Ambient Temperature: 32°F to 120°F (0°C to 49°C) Relative Humidity: 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F) For use indoors in a dry location Installation The BG-12LX will mount semi-flush into a single-gang, double- gang, or standard 4(10.16cm) square electrical outlet box, or will surface mount to the model SB-i 0 or SB-I/O surface back- box. If the BG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4 (10.16 cm) or double-gang boxes (not with single-gang boxes). 8 Fire utarms by Honeywell Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 - 159 with Breakaway Tab removed for MS-9600, 1 - 99 and MS-9200UDLS, 1 - 50 for MS-9050UD). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored LEXAN (or polycarbonate equivalent) with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-i 0 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. DF-52013:B ° 10/20/2008 -Page 1 of 2 DF-E2418:13 • A1-20 MS-9050UD(E) Fire Alarm Control Panel with DACT General The Fire'Lite MS-9050UD(E) is a Fire Alarm Control Panel (FACP) and Digital Alarm Communicator/Transmitter (DACT) combined into one circuit board. This compact, intelligent addressable control panel supports up to 50 addressable devices of any type of detectors and modules. With an exten- sive list of powerful features, the MS-9050UD programs just like Fire-Lite's larger products, yet fits into applications previously served only by conventional panels. The MS-9050UD's integral DACT transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the pub- lic switched telephone network. It also allows remote and local programming of the control panel using the PK-CD Upload/ Download utility. In addition, the control panel may be pro- grammed or interrogated off-site via the public switched tele- phone network. Any personal computer with Windows 95 or greater, and compatible modem with a speed of 14.4 kbps or faster and Fire-Lite Upload/Download software kit PK-CD, may serve as a Service Terminal. This allows download of the entire program or upload of the entire program, history file, walktest data, current status and system voltages. The power supply and all electronics are contained on a single circuit board supported on a new quick install chassis and housed in a metal cabinet. Available accessories include local and remote upload/download software, remote annunciators, and reverse polarity/city box transmitter. (4XTMF) New options include a UL listed printer, PRN-6F and the new IPDACT Internet Monitoring module. The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet saving the monthly cost of two telephone lines. Although not required, the second- ary telephone line may be retained providing backup communi- cation over the public switched telephone line. NOTE: Unless otherwise specified, the term MS-9050U0 is used in this data sheet to refer to both the MS-9050U0 and the MS- 9050U0E FACPs. For MS-9050U0C, refer to DF-60445. Features Listed to UL Standard 864, 9th edition. Auto-program (learn mode) reduces installation time. Reports two devices set to the same address. On-board DACT. Two independently programmable Style Z (Class A) or Style V (Class B) NAC circuits. Selectable strobe synchronization for System Sensor, Whee- lock, and Gentex devices. Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules. Two programmable relays and one fixed trouble relay. Built-in Programmer. Telephone Line Active LEDs. ElA-232 PC interface. Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings control. History file with 500 event capacity. Automatic detector sensitivity testing (NFPA 72 compliant). Automatic device type-code verification. (a Fire uearms by Honeywell Point trouble identification. Waterf low selection per module point. Alarm verification selection per detector point. Maintenance alert warns when smoke detector dust accumu- lation is excessive. One-person audible or silent walk test with walk-test log and printout. System alarm verification selection per detector point. PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72 compliant). Up to eight ANN-BUS annunciators. Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator. Upload/Download (local or remote) of program and data via integral DACT. SLC COMMUNICATION LOOP Single addressable SLC loop which meets NFPA Style 4, 6 and 7 requirements. 50 addressable device capacity (any combination of address- able detectors and modules). Compatible with Fire-Lite's addressable devices (refer to SLC Wiring Manual). NOTIFICATION APPLIANCE CIRCUITS (NACS) Two independently programmable -output circuits. Circuits can be configured for the following outputs: - Style V (Class B) - Style Z (Class A) - Door Holder Service (cannot be used for notification appliances) - Aux Power Source (cannot be used or notificaton appliances) Silence Inhibit and Autosilence timer options. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAC. 2.5 A total power for NACs. NOTE: Maximum or total 24V0C system power shared between all NAC circuits and the ANN-BUS is 2.7.4. DF-52418:B.05/18/2039—Page 1 of 4 ECC-125DA: Distributed (Remote) Audio Amplifier, 125 watts. Please refer to the data sheet DF-60763 for more information. ECC-125DAE: Export version. Distributed (Remote) Audio Amplifier, 125 watts. (240 VAC, 50Hz). Please refer to the data sheet DF-60763 for more information. ECC-CE4: Distributed Audio Speaker Circuit/Zone expander module. ECC-FFT: Fire Fighter Telephone System. Please refer to the data sheet DF-60765 for more information. FPJ-F: Remote Phone Jack. FHS-F: Fire Fighters Remote Handset. FHSC-RF: Fire Fighters Handset Cabinet Recessed. FHSC-SF: Fire Fighters Handset Cabinet Surface Mount MMF-301: Addressable Mini-Monitor Module. 1300: SLC Line Isolation Module. TA-CE: Optional Trim Ring. THUMBLTCH: Optional Thumb Latch. (Non UL-Listed). CHG-75: 25 to 75 ampere-hours (AH) External Battery Charger. CHG-120F: 25-120 ampere-hours (AH) External Battery Charger. ECC-MICROPHONE: Replacement Microphone only. BAT-1270: Battery, 12 volt,7.0 AH (Two required). BAT-12120: Battery,12 volt,12.0 AH (Two required). BAT-12180: Battery, 12 volt, 18.0 AH (Two required). Wiring Requirements See product manual, part number LS10001-000FL-E for detailed wiring requirements. Total System Capacity: (ECC-5011 00(E) only) Total Built-in Audio Power: 50 Watts. Total Expandable Audio Power: 100 Watts. Total Built-in Speaker Circuits: 2. Total Expandable Speaker Circuits: 8. Audio Message Max Time Duration: 60 seconds. External Audio Input: 1. Total System Capacity: (Fully Loaded System) Total Distributed Audio Power: 1100 Watts. Total Speaker Circuits Per System: 24. Total Remote Consoles Supported: 8. Total Distributed Audio Amplifiers Supported: 8. Electrical Specifications PRIMARY (AC) POWER (TB 15) ECC-50/100: 120 VAC, 60 Hz, 3.5 amps (HOT, NEU). ECC-50/100E: 240 VAC, 50 Hz, 2.0 amps (HOT=HotLegl, NEU=HotLeg2). Wire size: minimum #14 AWG (2.00mm2) with 600 V insulation. SECONDARY POWER (BATTERY) CHARGING CIRCUIT 'Supports lead-acid batteries only. Float chãre voltage at 27.3V Maximum charge current: 1.0 Amp Maximum battery charge capability: 2.8 Amps, 26AH ECC fcabinet rnäi8 a ery. rin1num Battery sizi12AmpHour.- - AC LOSS RELAY CONTACT RATING (TB3) 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive). FORM C - TROUBLE RELAY CONTACT RATING (TB2) 2.0 amps @ 30 VDC (resistive), 0.5 amp @ 30 VAC (resistive). MNS ACTIVE RELAY CONTACT RATING (TB1) 2.0 amps @ 30 VDC (resistive), 0.5 amps © 30 VAC (resistive). NOTIFICATION APPLIANCE CIRCUIT (NAC) OUTPUT RATING (TBI9) One (1) Style Y (Class B) or Style Z (Class A) circuit. Power-limited circuitry, (Class 2) supervised. Nominal operating voltage: 24 VDC. Maximum signaling current for special application power: 2.OA. Maximum signaling current for regulated power: 200mA. Maximum wiring impedance: 1 Q Current limit: fuse-less, electronic, power-limited. End-Of-Line Resistor: 4.7 KZ 1/2 watt, (P/N 71252) required for Style Y (Class B) operation. Refer to the Device Compatibility Document 15384 for listed compatible devices. NAC FOLLOWER OUTPUT REMOTE SYNC (TB18) Connections for FACP NAC synchronization trigger signal. Output terminals: pass-through to other system compo- nents. Trigger input voltage: 9 to 32 VDC, 24 VDC rated. Input current draw in Alarm condition: 10 mA at rated volt- age. SPECIAL APPLICATION POWER (AUX. POWER) (TB 17) 500 mA @ 24 VDC. Used for powering addressable modules and associated End-of-Line power supervision relays. Power-limited circuitry. Refer to the Device Compatibility Docu- ment 15384 for a list of compatible devices. SPEAKER VOLUME CONTROL OVERRIDE (TB23) Style Y (Class B) or Style Z (Class A) circuit. Special application power. Power-limited circuitry, supervised. Nominal operating voltage: 24 VDC. Maximum signaling current: 0.25 amps. Current limit: fuse-less, electronic, power-limited. End-Of-Line Resistor: 4.7 K1, 1/2 watt, (P/N 71252) required for Style V (Class B) operation. Speaker Circuits Primary Speaker Circuit (TB20) Secondary Speaker Circuit (TB21) (with optional amplifier only). - Circuit can be wired Style V (Class B) or Style Z (Class A). - Power-limited circuitry. - Normal Operating Voltage: 25 VRMS © 2 amps max and maximum Load Impedance of 12.5Q (70.7 VRMS @ 700 mA max. with maximum load Impedance of 100CI opera- DF-60734:A2 • 8/22/13 - Page 5 of 8 SYSTEM SPECIFICATIONS System Capacity Intelligent Signalling Line Circuits . 1 Addressable device capacity..............................................50 Programmable software zones...........................................20 Annunciators.........................................................................8 Electrical Specifications condensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic compo- nents may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80°F. NFPA Standards AC Power: MS-9050U0 120 VAC, 60 Hz, 3.0 A. MS-905OUDE: The MS-9050UD(E) complies with the following NFPA 72 Fire 240 VAC, 50 Hz, 1.5 A. Wire size: minimum 14 AWG (2.00 mm2) Alarm Systems requirements: with600Yinsulation. Nonpower-limited, supervised. - LOCAL (Automatic, Manual, Waterflow and Sprinkler Battery: . Two °i'VTäAH lead-acid batteries. Battery Char Supervisory). _____ 50oDiiiTfl,ldg maximum of two —AUXILIARY (Automatic, Manual and Waterflow) (requires Capacity 7118 A 7 ______ t ARbiee.__. 4XTMF). Communication Loop: Supervised and power-limited. - REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and Notification Appliance Circuits: Terminal Block provides con- supervisory relays may be connected to UL 864 listed nections for two NACs, Style Y (Class B) or. Style Z (Class A). transmitters. For reverse polarity signaling of alarm and Special Application power. Power-limited, supervised circuitry. trouble, 4XTMF is required.) Maximum signaling current per circuit: 2.5 A. End-of-Line Resis- tor: 4.7 kohm, 1/2 watt (P/N 71252 UL listed) for Style V (Class B) - PROPRIETARY (Automatic, Manual and Waterflow). NAC. Refer to the Fire-Lite Device Compatibility Document for - CENTRAL STATION (Automatic, Manual and Waterflow, listed compatible devices, and Sprinkler Supervised). - AT DQflM 1Ath, P kt..c,,ifr'hd nata Mt Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0 A © 30 VDC (resistive), 0.5 A © 30 VAC (resistive). Form-C relays, nonpower-limited, nonsupervised. Cabinet Specifications Door: 19.26 (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65' (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 491C/32 - 120°F and at a relative humidity 93% ± 2% RH (non- work) Agency Listings and Approvals The listings and approvals below apply to the basic MS- 9050UD(E) control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S624 FM approved CSFM: 7165-0075:210 MEA: 442-06-E NOTE: See DF-60445 for ULC-listed model. FlreLite® Alarms® and System Sensor® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. 93=1=1 We cannot cover all specific applications or anticipate all requirements. ffilliffEMNS & MMUFACTUMNS All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— DF-52418:13 • 05/18/2009 SYSTEM ~4 SENSOR Selectable Output Horns, Strobes, and Horn/Strobes SpectrAlert' Advance selectable-output horns, strobes, and horn/strobes are rich with features guaranteed to cut installation times and maximize profits. Features Electrically compatible with existing SpectrAlert products Automatic selection of 12-or 24-volt operation at 15 and 15/75 candela Plug-in design The SpectrAlert Advance series of notification appliances is designed to simplify installations, with features such as plug in designs, instant feedback messages to ensure correct installation of individual devices, and 11 field-selectable candela settings for wall and ceiling strobes and horn/strobes. Field selectable candela settings on wall and ceiling units: 15, 15/75, When installing Advance products, first attach a universal mounting 30, 75, 95, 1 10, 115, 135, 150, 177,185 plate to a four-inch square, four-inch octagon or double-gang Same mounting plate for wall- and ceiling-mount units junction box.The two-wire mounting plate attaches to a single-gang junction box. Shorting springCIII mounting plate or LUIIIIIIUII.y LlItLlS belore installation Tamper resistant construction Outdoor wall and ceiling products rated from —40°F to 151°F Design allows minimal intrusion into the back box Horn rated at 88+ dbA at 16 volts Rotary switch for horn tone and three volume selections Outdoor products UL listed to UL 1638 (strobe) and UL 464 (horn) outdoor requirements Outdoor products NEMA 4X rated Compatible with MDL sync module Agency Listings SIGNAUNG I'JIEA 7125-I653J869ndoor 0-abel) 7300-I 653:187 Iou1dl 7125-1653:188 (la,n/11,obel, LISTED APPROVED approved chl,ae/5110be5) 7135-1653:189 o,ns,chIrnes) 54011 3023572 M0A452-05-E S5512 53593 Next, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. Finally, attach the horn, strobe or horn/strobe to the mounting plate by inserting the product's tabs in the mounting plate's grooves. The device will rotate into position, locking the product's pins into the mounting plate's terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. The SpectrAlert Advance series includes outdoor notification appliances. Outdoor strobes and horn/strobes (two wire and four wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. SYSTEM $ SENSOR Indoor Selectable Output Speaker Strobes and Dual Voltage Evacuation Speakers The new SpectrAlert* Advance selectable output speaker strobes and dual evacuation speakers can reduce ground faults and allow faster installation. Features Plug-in design Protective cover isolates speaker components, reduces ground faults Electrical compatibility with existing SpectrAlert products Field selectable candela settings on wall and ceiling units: Standard: 15, 15/7530,75,95,110,115 High: 135,150,177,185 Shorting spring on mounting plate tests continuity before installation Rotary switch simplifies field selection of speaker voltage (25 and 70.7 Vrms) and power settings (¼, ½, 1 and 2 watts) Universal mounting plate for wall- and ceiling-mount units Compatible with System Sensor synchronization protocol SP speakers offer high fidelity sound output SPV speakers offer high volume sound output Automatic selection of 12-or 24-volt operation at 15 and 15/75 candela No extension ring required Ceiling and wall mount application Optional tamper resistant Torx head screw included Agency Listings SGNAUNG ® 0 - 4MEA LISTED approved S4048 7320.1653:201 1 0-08-0 .1 ALVA !'S SnO. The SpectrAlert Advance Series of speakers and speaker strobes is designed to reduce grouid faults. The plug-in design allows the installer to pre-wife mounting plates and dress the wires before plugging in the speakers.The plastic cover prevents nicked wires by covering exposedi speaker components. This design also allows faster installations with instant feedback to ensure that wirirç is propely connected, rotary switches to select voltage and power settings, and 11 field selectable candela settings for wall and ceiling speaker strobes. The low total harmonic distortion of the SP speaker offers high fidelity sound ot2ut while the SPy speaker offers high volume sound output fo use in high ambient noise applications. SpectrAlert Advance makes installation easy Attach a universal mounting plate to a 4 x 4 x 21/8 inch back box. Flush mount applications are achievable without the need for an extension ring. Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate. Attach the speler or speaker strobe to the mounting plate by inserting the pr-.duct tabs into the mounting plate .grooves. Rotate the device into position to lock the product pins into the mounting plate terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. TE LG UAR D CELLULAR ALARM TG=7FS COMMUNICATOR FOR 3G/4G NETWORKS COMMERCIAL FIRE PRODUCT FEATURES I- Meets UL 864 requirements for sole, primary or backup path communications. I- Provides RMR protection by leveraging technology that operates on 3G/4G networks. 1- Supports listen-in, two-way voice verification over cellular. I- Minimizes false alarms by providing dual paths for self-tests. 1- Falls back to 2G (GSM) if a 3G/4G network isn't available. The Telguard TG-7FS is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2013 Edition of NFPA 72, the TG-7FS can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS because of the new sixty minute supervision mode. The TG-7FS can also be installed as a backup path and upgraded to sole path at a later date. CELLULAR ALARM TG=7FS COMMUNICATOR FOR 3G/4G NETWORKS' 13 COMMERCIAL FIRE PRODUCT FEATURES I- Meets UL 864 requirements for sole, primary or backup path communications. I- Provides RMR protection by leveraging technology that operates on 3G/4G networks. I- Supports listen-in, two-way voice verification over cellular. I- Minimizes false alarms by providing duall paths for self-tests. )- Falls back to 2G (GSM) if a 3G/4G network isn't available. The Telguard TG-7FS is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2013 Edition of NFPA 72. the TG-7FS can serve as the sole communications path for the fire'alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the enduser significantly less than a dedicated landline. For each landline replaced with a TG-7FS, the monthly communicationts bill decreases. By being able to signal failures to the centrall station within six:y minutes of an outage, the TG-7FS can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS because of the new sixty minute supervision mode. The TG-7FS can also be installed as a backup path and upgraded to sole path at a later date. YII.'V. TE LG UAR D I FA14UIb 'i• ATO% VOLY TELGUARDS I S.' Telguard technology lows full datare3orting for uriliriiited point-to-point signal details and maximum transmitting' power for ijrarfsëiver— 55 supe'ior in-building penetration. : lllar radio. .. S 3M 850 Z: Glass 42f Telguard products are easy to install, ecdnomical, and UL Listed. M 19 z: Glass I (ia'). 1TS WGDMA F0 E5i9OO1I-z Accessories*... .. . '. . ... ttenna 9" dipoleth 2d8i gain • AC) 12 ACD 35 ACD 50 ACID 100 ft O IL cableaod uni'wersal mounting 1/35/50/100 feédf'tlok, loss, high"eformance cable.. cket . .. .., . . - HG)-0: High gain directional antenna EXD 0 External antenna ling . •- *.: :- erating Ell vironrrt . :5 condesjg). . S UL Listings •. :' 5 Commercial Fire a Commercial Burglary. - Residential 864 • Control units & . 365 Police Station ... 985 • Household fire access-vies for !ire .- connectedbu'rgar .warning systems alarm systems alarm units and systems . -. . 1610 Central station burglar .- - . alarm units; . Line security servcies For h6 rros: current product spochcatons and UL LsUngs visit wni.Teiguard.com. . .,. -.. Ui SECURITY \IV$ LISTED NIF ls Telguard a Division of Telular Corporation Cumberland Center IV 3225 Curriberland Blvd Suite 300 Atlanta GA 3033!9.-,USA 800-229-2326, Option - wwvTguard.corn• COpyright :c2012 felular Corporation -.All Rights Reserved . .. ..•' S .5. .. . ... CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0109 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR C0RP2727 Paces Ferry Rd., Ste. 1-800, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju@telular.com DESIGN: Models TG7G0004, TG7GFS04, and TG7GA004 digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models TG7G0004 and TG7GA004 are household apploication and Mode TG7GFS04 is for commercial application. Refer to listee's printed data sheet for additional detailed product description and operational considerations INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTE: Burglary and other non-fire functions were not examined. Corrected 10-09-13 jp This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Stainless St Custom Loc PvaliaDIe In sizes AA, A& D As Built Drawings Cabinet The DBX "AS BUILT DRAWINGS" Cabinet offers the conve- nience of having building layouts and alarm documents readily accessible for fire departments and other authorized person- nel. This surface mount cabinet is fabricated from 16 gauge'-steel with a durable, baked on, red textured powder coat finish, white 1" high lettering and features a stainless steel piano hinge and a high security CAT 30 keyed door lock. Standard Features: 16 gauge steel construction Durable red textured finish White 1" indelible lettering "AS BUILT DRAWINGS" Stainless steel piano hinge with CAT 30 keyed door lock Surface mount box Wall mounting holes Options: Custom finish Custom legend Custom lock Flush Flange AAFMAW-0 — ISO 9001' REGISTERED NFPA Made In U.S.A. Space Age Electronics, Inc. 2007 ED0132 LT10045 Rev.F 1/2 ADA Space Age Electronics, Inc. Www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! [1 s steel hinge SPACE AGE ELECTRONICS, INC. Specifications: The DBXAs Built Drawings Cabinet is constructed of 16 gauge (.062 thk.) cold rolled steel and fin- ished with a durable red textured, heat-resistant baked-on enamel finish. The front cover includes a durable label displaying "AS BUILT DRAWINGS" in 1" white indelible lettering, applied to the cover relative to the orientation of the installed back box. The front cover features a high security CAT 30 keyed door lock. Custom finish, legend and lock available. Back box universal surface mount design and wall mounting holes. Size Dimensions of Cabinet W H D AA 12 1/4" 14 1/4" 4" A 26 1/4" 14 1/4" 4" D 26 1/4" 23 5/8" 4" Custom labels available Ordering Information: Part # Description SSU00674 DBXAA As Built Drawings Cabinet, Red SSU00677 DBXA As Built Drawings Cabinet, Red SSU00678 DBXD As Built Drawings Cabinet, Red Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! SSU00680 DBXA Semi Flush Flange, Red SSU00681 DBXD Semi Flush Flange, Red This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0132 LT10045 Rev.F 2/2 ) Project: To Install a fire sprinkler alarm monitoring system to be monitored by a 24 hr. U. L. Approved Central Station For: F-FZaith ariurch ilanch Carlsbad, CA 12232 Thatcher Court, Poway, CA 92064 State License No. 626615 C-7 /C-10 PHONE: (858) 391-2500 FAX: (858) 391-2599 SAII YqO3 3JII N. F. P.A.. Record I of Completion: Instructions.: There are 3 copies of this document each requires the following: All areas of the document have been completed with the exception of: (Please verify the counts and types of devices as this document is based on equipment that was specified before plans check) Section 1 The date the contract for service is signed, shall be added to this section prior to the final inspection with the AHJ. A copy of this agreement shall be providing for verification by the AHJ at the final. Note: Contact amounts may be whited out. The AHJ only wants to see the signatures, dates, and services to be provided on the contract. Section 2 This is to be completed when the installation of the system is complete and is found to be in operational order by the installer. Section 3 This is to be completed when the persons doing the pre test, test the installation prior to the final inspection with the AHJ. As Pro-1 will be assuming the responsibility for this installation and the associated liability, this test is to be performed by a Pro-1 employee that is experienced in this type of installation and understands the functions of the system being tested. Section 11 This is to be completed at the time the system is inspected and tested with the IE... and Pro-1 personnel. When section ii has been completed and signed by all parties the distribution shall be has follows: i copy to the account file at Pro-1 i copy to the AHJ 1 copy to the owner or owner's representative I-- N.F Record of Completion Name of Protected Property: Address: Rep. of Protected Prop. (Name\phone) Authority Having Jurisdiction. Address I Phone: Faith Community Church 2700 Rancho Pancho Carlbad City Fire I - 1. Type(s) of system services n/a NFPA 72, Chapter 6 - Local If alarm is transmitted to location(s) off premise, list where received: n/a NFPA 72, Chapter 6 - Emergency Voice I Alarm Service Quantity of voice\alarm channels: single: ______ multiple: Quantity of speakers installed: quantity of speaker zones: - Quantity of telephones or telephone jacks included in system: n/a NFPA 72, Chapter 9 - Auxiliary Indicate type of connection: Local energy, ____ shunt, ____ parallel telephone, Location and telephone number for receipt of signals: n/a NFPA 72, chapter 6 - Remote Station Location for receipt of alarm signals: Location for receipt of supervisory signals: n\a NFPA 72, chapter 6 - Proprietary If alarms are retransmitted to public fire service communications center or others, indicate location and telephone number of the organization receiving Alarm: Indicate how alarm is retransmitted: NFPA 72, chapter 6 - Central Station the prime contractor: PROTECTION ONE ALARM MONITORING, INC. 4221 W. JOHN CARPENTER FWY IRVING, TX 75063 Central station location: Same As Above (I Means of transmission of signals from the protected premise to the Central Station: McCulloh multiplex one way radio other Digital alarm communicator two way radio Means of transmission of the alarms to the public fire service communications center: System location: 2700 Rancho Pancho Carlsbad, CA Organization name\phone representative name\phone Installer Protection One (858) 391-2500 Supplier Protection One (858) 391-2500 Service Co. Protection One (858) 391-2500 Location of record (as-built) drawings: Protection One 12232 Thatcher Court Poway, CA 92064 Location of owner's manuals: Operation directions on site Location of test report: A contract, dated 2014, for test and inspection in accordance with NFPA Standard(s) no.(s)72 , dated 2013 , is in effect. 2. Certification of system installation (Fill out after installation is complete and wiring checked for opens, shorts, ground faults, and improper branching, but prior to conducting the operational acceptance tests.) This system has been installed in accordance with the NFPA standards as listed below, and was inspected by ____on includes the Devices listed below and have been in service since XXX NFPA 72, chapters 1 3456789 10 11 (circle all that apply) XXX NFPA 70, national electrical code, article 760 XXX manufacturer's instructions XXX Other (specify): _CFC 2013, CBC 2013, Title 19 & 24 as Amended Signed: date: Organization: Protection One Alarm Monitoring CO. 3. Certification of system oDeration All operational features and functions of this system were tested by on _ - and found to be operating Properly in accordance with the requirements of: XXX NFPA 72, chapters 1 3456789 10 11 (circle all that apply) XXX NFPA 70, national electrical code, article 760 XXX Manufacturer's instructions XXX Other (specify) CFC 2013, CBC 2013 title 19 & 24 as amended Signed: date: Organization: Protection One Alarm Monitoring Co. (Protection One) 4. Alarm initiating devices and circuits (indicate quantity of devices) Manual: I manual stations X no coded, activating ______ transmitter(s) coded Combination manual fire alarm and guard's tour coded stations Automatic: *note: this count is for new devices only Coverage: ______complete: _________partial: I smoke detectors _____ion X photo 7 duct detectors _____ion X photo heat detectors ft rr ft\rr rc I sprinkler water flow switches: noncoded, activating transmitters coded Other (list): 5. Supervisory siunal initiatinci devices and circuits (indicate auantitv of devices Guard's tour: A)coded stations noncoded stations activating transmitters compulsory guard tour system comprised of transmitter stations and Intermediate stations Note: combination devices recorded under 4(b) and 5(a) I Valve supervisory signaling attachments Valve supervisory switches activating transmitters building temperature points site water temperature points site water supply level points Electric fire pump: fire pump power fire pump running phase reversal Engine-driven fire pump: selector in auto position engine or control panel trouble fire pump running c4 Engine-driven generator: selector in auto position control panel trouble transfer switches engine running Other supervisory function(s) (specify: 6. Alarm notification appliances and circuits Quantity of indicating appliance circuits connected to the system: Types and quantities of alarm indicating appliances installed: bells inch speakers horns chimes I other: Exteriorhornstrobe F)27visual signals type: Speaker I Strobes 24 with audible 3 w\0 audible G) I local annunciator *Note: this count is for new devices only 7.Signalinglinecircuits: Quantity and style (see NFPA 72, table 6-6) of signaling line circuits connected to system: Quantity: N/A style: N/A 8.Systempowersupplies Primary (main): ac nominal voltage: 18.5 current rating: 40va Over current protection: type: FUSED current rating: 40 y Location: Secondary (standby): XXX storage battery: amp-hour rating 18.00 Calculated capacity to drive system, in hours: X24 _60 Engine-driven generator dedicated to fire alarm system: Location of fuel storage: Emergency or standby system used as backup to primary power supply, instead of Using a secondary power supply: Emergency system described in NFPA 70, article 700 Legally required standby system described in NFPA 70, article 701 Optional standby system described in NFPA 70, article 702, which also meets the performance requirements of article 700 or 701. 9. System software Operating system software revision level(s): 5.24 Application software revision level(s): N/A Revision completed by: From company: 04, 1 Comments No Comme for Ceal Station or a2'ervice Final acceptance y - Title ) - date (signed) For central station or alarm Service Company ___Title date Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA Standards: None System deviations from the referenced NFPA Standards are: None (signed) for Central Station or alarm Service Company Title date Upon completion of the system(s) satisfactory test(s) witnessed (if required by the authority having jurisdiction) Representative Contractor's Material and Test Certificate for AbovegrIJFp W! PROCEDURE r3ve. Upon completion of work, Inspection and tests shall be made by the contractor's reresentCIL~tnU%)Eb All defects shall be corrected and system left in service before contractor's personnel flnall1eav A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners, and contractor. It Is understood the owner's representative's signature In no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. Property name V Date Property address 2200 Accepted by approving authorities (names) Address Plans Installation conforms to accepted plans E Yes 0 No V Equipment Used is approved fJ Yes No If no, explain deviations V Has person In charge of fire equipment been Instructed as Yes 0 No to location of control valves and care and maintenance of this new equipment? If no, explain? V Instructions V V V V Have copies of the following been left on the premises? FX Yes V No System components Instructions Yes No Care and maintenance Instructions Yes V No 3 NFPA 25 Yes No V Location of system Supplies buildings V - V Year of Orifice Temperature Make Model manufacture size Quantity rating Thc 34's 45 iMc. ________ Sprinklers 41 t.e& 'f4 4-2- 122>9 - Pipe and Type ofpipe fittings Type of fittings -f Maximum time to operate Alarm Valve or tlo' Indicator. Alarm device through test connection Typo Make Model Minutes Seconds Fç '2 S Dry valve V 0.0.0. Make Model Serial no. Make Model no. -Dry pIpe operating test Tmt1rip.—. through test connection1 -WaIer pressure Air presi.ue- _.__- air pressure TimO water reached test outlet1 Alarm operated properly V ______ Minutes Seconds psi Minutes Seconds Yes No Without 0.0.0. 4 . With explain V Operation E Pneumatic LJ Electric E Hydraulics pIng supervised E Yes E No Detecting media supervised No Doesivake-poperate from the manual trip, remote, or both Yes E No Deluge and preaction valves Is there an accessible each _ ..j_ino. ~circuit for testing? Yes 0 explain Make Model Does each circuit a supervisi ss alarm? Does each circuit operate valve release? Maximum time to operate release No Minutes Seconds Pressure Locatio -Make a or and model Setting Static pressure Residua sure (flowing) Flow rate reducing Inlet (psi) Outlet (psi) inlet (psi) Outlet (psi) TDw(gm). Test Hydrostatic Hydrostatic tests shall be made at not lesathan 200 psi (13.6 bar) for 2 hours or 50 psi (3.4 bar) above static pressure in excess of 150 psi (10.2 bar) for 2 hours. Differential dry-pipe valve clappers shall be left open during the test to prevent damage. All aboveground piping leakage shall be stepped. description Pneumatic: Establish 40 psi (2.7 bar) air pressure and measure drop, which shall not exceed 1½ psi (0.1 bar) In 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop, which shall not exceed 1½ psi (0.1 bar) in 24 hours. All piping hydrostatically tested at 2c psi (_ bar) for .2. hours if no, state reason Dry piping pneumatically tested M Yes E No I(A Equipment operates properly .Yes El No Do you certify ai the sprinkle( contractor that additives and corrosive chemicals, sodium 01cate or derivatives of sodium silicate, brine, or other corrosive chemicals were not used for testing systems or stopping leaks? Yes . No Tests Drain test Reading of gauge located near water supply test connection: t46 psi (...._bar) Residual pressure with valve in test I connection open wide: 14r psi (_bar) Underground mains and lead In connections to system risers flushed before connection made to sprinkler piping Verified by copy of the U Form No. 85B . VJ Yes No Other Explain flushed by installer of underground sprinkler piping Yes No If powder-driven fasteners are used in concrete, has Yes E No if no explain representative sample testing be satisfactorily completed? Blank testing Number used Locations Number removed gaskets Welding piping Yes C3 No If yes... Do you certify as the sprinkler contractor that welding procedures comply Yes No with the requirements of at toast AWS B2.1? Welding e ng Do you certify that the welding was performed by welders qualified In Yes E No compliance with the requirements of at least AWS B2.1? Do-you certify that the welding was carried out in compliance with a documented Yes [] No qualify control procedure to ensure that all discs are retrieved, that openings In piping are smooth, that slag and other welding residue are removed, and that the internal diameters of piping are not penetrated? Cutouts (discs) Do you certify that you have a control feature to ensure that Yes No all cutouts (discs) are retrieved? .Hydraulic nameplate NdaPlate.p.rovided' Yes . No If no,.explaln Date, left In service with alicontrol valves open Remarks • Signatures ç Name of sprinkler contractor , •. Tests witnessed. by Fô pewa, (signed)' Titial Date c 1• ;pnkl... life Date Additional explanatlohs and notes